Anda di halaman 1dari 2774

Total Access 5000 System Release 5.

7 and
Carrier Ethernet System Release 2.0.1
Document Number: 6TANV57CLI-35A
January 2011

reference guide

Total Access/NetVanta Carrier


CLI Dictionary

Total Access/NetVanta Carrier CLI Dictionary

Front Matter

Trademarks
Anybrandnamesandproductnamesincludedinthisdocumentare
trademarks,registeredtrademarks,ortradenamesoftheirrespectiveholders.

To the Holder of this Document


Thecontentsofthisdocumentarecurrentasofthedateofpublication.ADTRANreserves
therighttochangethecontentswithoutpriornotice.
InnoeventwillADTRANbeliableforanyspecial,incidental,orconsequentialdamagesor
forcommerciallossesevenifADTRANhasbeenadvisedthereofasaresultofissueofthis
document.

About this Document


ThisdocumentcontainsallCommandLineInterface(CLI)commandsfortheADTRANTotal
Access/NetVantaCarrierproducts.Thisdocumentprovidesdetailedinformationaboutall
commandsthatareavailablethroughtheproducts.
Theintendedaudienceforthisinformationissystemmanagementpersonnelresponsiblefor
theconfigurationsystemapplicationsusingCLI.Useofthesecommandsassumesfamiliarity
withtheintendeduseoftheproducts,conceptspeculiartothisproduct,andacomputer
operationsskillset.
RelatedinformationcanbeobtainedbyreferringtotheapplicableSystemandComponent
documentation.

901ExplorerBoulevard
P.O.Box140000
Huntsville,AL358144000
UnitedStates
(256)9638000
2011ADTRAN,Inc.
AllRightsReserved.

ii

6TANV57CLI-35A

Revision History
Revision

Date

January2011

Description
InitialRelease.ThisdocumentsupportstheTotalAccess5000
SystemRelease5.7andCarrierEthernetSystemRelease2.0.1.

Conventions
Thefollowingtypographicalconventionsareusedinthisdocument:
Thisfontindicatesacrossreferencelink.
This fontindicatesscreenmenus,fields,andparameters.
THIS FONTindicateskeyboardkeys(ENTER,ESC,ALT).Keysthataretobepressedsimulta
neouslyareshownwithaplussign(ALT+X indicatesthattheALT keyandX keyshouldbe
pressedatthesametime).
Thisfontindicatesreferencestootherdocumentationandisalsousedforemphasis.
Thisfontindicatesonscreenmessagesandprompts.
Thisfontindicatestexttobetypedexactlyasshown.
This fontindicatessilkscreenlabelsorothersystemlabelitems.
Thisfontisusedforstrongemphasis.

6TANV57CLI-35A

iii

Total Access/NetVanta Carrier CLI Dictionary

Hazard Classifications
Thefollowinghazardclassificationsareusedinthisdocument:

DANGER
DANGERindicatesahazardwithahighlevelofriskwhich,ifnotavoided,
willresultindeathorseriousinjury.

WARNING
WARNINGindicatesahazardwithamediumlevelofriskwhich,ifnot
avoided,couldresultindeathorseriousinjury.

CAUTION
CAUTIONindicatesahazardwithalowlevelofriskwhich,ifnotavoided,
couldresultinminorormoderateinjury.CAUTIONcanalsobeusedtoalert
againstunsafepracticesassociatedwitheventsthatcouldleadtopersonal
injury.

NOTICE
Noticecalloutsindicateapotentiallyhazardoussituationnotrelatedto
personalinjury,suchasmessagesrelatedtopropertydamageonly.

NOTE
Notesinformtheuserofadditional,butessential,informationorfeatures.

iv

6TANV57CLI-35A

Icons
ThefollowingiconsareusedthroughouttheADTRANdocumentsuite:

jobAid
installation guide
deployment guide
application guide
reference guide
diagnostic guide
safety and regulatory
engineering guide
release notes
upgrade guide
user guide

Training
ADTRANofferstrainingcoursesonourproducts.Thesecoursesincludeoverviewson
productfeaturesandfunctionswhilecoveringapplicationsofADTRANproductlines.
ADTRANprovidesavarietyoftrainingoptions,includingcustomizedtrainingandcourses
taughtatourfacilitiesoratcustomersites.
Forinquiriesconcerningtraining,contactADTRAN:
TrainingPhone:8006151176,ext.6303
TrainingFax:2569636217
TrainingEmail:training@adtran.com

6TANV57CLI-35A

Total Access/NetVanta Carrier CLI Dictionary

vi

6TANV57CLI-35A

Contents
Introduction
Scope of this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro-1
In this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro-1
Command Description Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro-2

Section 1
Understanding CLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Scope of this Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
In this Section. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Accessing the Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Security Login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2

Command Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3


CLI Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
CLI Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
CLI Input Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

Section 2
Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Scope of this Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Command Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Common Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
clear [arp|counters|node-information] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
clear arp <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-29
clear counters [aaa|adsl|backplane|dynamic-counter|e1|efm-group|efm-link|efmport|erps|ethernet|evc|evc-map|frame-relay|fxs|gigabitethernet|hdsl2|hdsl4|lacp|muxponder-highspeed|muxponder-midspeed|packettiming|policer|ppp-group|ppp-link|pseudowire|shdsl|t1|t3|ten-gigabit-ethernet|vdsl] 230

6TANV57CLI-35A

vii

Total Access/NetVanta Carrier CLI Dictionary

clear counters aaa [local|radius|tacacs+] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


clear counters adsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters backplane <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters dynamic-counter <shelf/slot/index> . . . . . . . . . . . . . . . . . . . . . . .
clear counters e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . .
clear counters efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters erps <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet [<shelf/slot/port>|cfm] . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm association WORD . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm domain WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm interface efm-group <shelf/slot/group> . . . . . . . . . .
clear counters ethernet cfm interface ethernet <shelf/slot/port> . . . . . . . . . . . . .
clear counters ethernet cfm interface gigabit-ethernet <shelf/slot/port> . . . . . . .
clear counters ethernet cfm level <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm mep <1-8191> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ethernet cfm vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . . . . .
clear counters evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters evc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters evc WORD <shelf/slot> ip igmp . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters evc-map WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters frame-relay [<shelf/slot/group>|dlci] . . . . . . . . . . . . . . . . . . . . . . .
clear counters frame-relay <shelf/slot/group> dlci . . . . . . . . . . . . . . . . . . . . . . . .
clear counters frame-relay <shelf/slot/group> dlci <16-991> . . . . . . . . . . . . . . . .
clear counters fxs <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters hdsl2 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters hdsl4 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters lacp <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .
clear counters muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .
clear counters packet-timing <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters policer WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ppp-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . .
clear counters probe responder twamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters pseudowire [<shelf/slot>|<shelf/slot/pwe>] . . . . . . . . . . . . . . . . .
clear counters shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . . . . . .
clear counters t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear counters ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . .
clear counters vdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear ethernet cfm mep remote association WORD . . . . . . . . . . . . . . . . . . . . . .
clear ethernet cfm mep remote domain WORD . . . . . . . . . . . . . . . . . . . . . . . . . .
clear ethernet cfm mep remote down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

viii

2-33
2-34
2-35
2-36
2-37
2-38
2-39
2-40
2-41
2-42
2-43
2-44
2-45
2-46
2-47
2-48
2-49
2-50
2-51
2-52
2-53
2-54
2-55
2-56
2-57
2-58
2-59
2-60
2-61
2-62
2-63
2-64
2-65
2-66
2-67
2-68
2-69
2-70
2-71
2-72
2-73
2-74
2-75
2-76
2-77
2-78
2-79

6TANV57CLI-35A

Contents

clear ethernet cfm mep remote interface efm-group <shelf/slot/group> . . . . . . . 2-80


clear ethernet cfm mep remote interface ethernet <shelf/slot/port> . . . . . . . . . . 2-81
clear ethernet cfm mep remote interface gigabit-ethernet <shelf/slot/port> . . . . 2-82
clear ethernet cfm mep remote level <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-83
clear ethernet cfm mep remote local-mep <1-8191> . . . . . . . . . . . . . . . . . . . . . . 2-84
clear ethernet cfm mep remote remote-mep <1-8191> . . . . . . . . . . . . . . . . . . . . 2-85
clear ethernet cfm mep remote vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . . . 2-86
clear ip file-server download-cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-87
clear mac address-table <shelf/slot> [authenticated|dynamic|multicast|static] . . 2-88
clear mac address-table <shelf/slot> address xx:xx:xx:xx:xx:xx . . . . . . . . . . . . . 2-90
clear mac address-table interface ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . 2-91
clear mac address-table interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . 2-92
clear node-information <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-93
clear performance-statistics [adsl|backplane|e1|efm-group|efmlink|erps|ethernet|evc|evc-map|frame-relay|gigabitethernet|gpon|hdsl2|hdsl4|muxponder-highspeed|muxponder-midspeed|policer|pppgroup|ppp-link|pseudowire|shdsl|t1|t3|ten-gigabit-ethernet|vdsl] . . . . . . . . . . . . 2-94
clear performance-statistics adsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-96
clear performance-statistics backplane <shelf/slot/port> . . . . . . . . . . . . . . . . . . . 2-97
clear performance-statistics e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . 2-98
clear performance-statistics efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . 2-99
clear performance-statistics efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] . 2-100
clear performance-statistics erps <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . 2-101
clear performance-statistics ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . 2-102
clear performance-statistics evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-103
clear performance-statistics evc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . 2-104
clear performance-statistics evc-map WORD <shelf/slot> . . . . . . . . . . . . . . . . 2-105
clear performance-statistics frame-relay [<shelf/slot/group>|dlci] . . . . . . . . . . . 2-106
clear performance-statistics frame-relay <shelf/slot/group> dlci . . . . . . . . . . . . 2-107
clear performance-statistics frame-relay <shelf/slot/group> dlci <16-991> . . . . 2-108
clear performance-statistics gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . 2-109
clear performance-statistics gpon <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-110
clear performance-statistics hdsl2 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-111
clear performance-statistics hdsl4 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-112
clear performance-statistics muxponder-highspeed <shelf/slot/port> . . . . . . . . 2-113
clear performance-statistics muxponder-midspeed <shelf/slot/port> . . . . . . . . 2-114
clear performance-statistics policer WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-115
clear performance-statistics ppp-group <shelf/slot/group> . . . . . . . . . . . . . . . . 2-116
clear performance-statistics ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] . 2-117
clear performance-statistics pseudowire [<shelf/slot>|<shelf/slot/pwe>] . . . . . . 2-118
clear performance-statistics shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-119
clear performance-statistics t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . 2-120
clear performance-statistics t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-121
clear performance-statistics ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . 2-122
clear performance-statistics vdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . 2-123
clear processes cpu max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-124
clear processes cpu max <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-125

6TANV57CLI-35A

ix

Total Access/NetVanta Carrier CLI Dictionary

clear security account age all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


clear security account age username WORD . . . . . . . . . . . . . . . . . . . . . . . . . .
clear security password age all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear security password age username WORD . . . . . . . . . . . . . . . . . . . . . . . . .
clear splice-detect [hdsl2|hdsl4|shdsl] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear splice-detect hdsl2 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear splice-detect hdsl4 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clear splice-detect shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
configure terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
copy WORD [WORD|running-config|startup-config] . . . . . . . . . . . . . . . . . . . . .
copy file-server flash . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
copy file-server flash [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . .
copy file-server flash [<shelf/slot>|<remote-index>] WORD . . . . . . . . . . . . . . .
copy flash [ftp|tftp] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
copy ftp [flash|running-config|sca|startup-config] . . . . . . . . . . . . . . . . . . . . . . . .
copy running-config [WORD|ftp|startup-config|tftp] . . . . . . . . . . . . . . . . . . . . . .
copy sca [ftp|tftp] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
copy startup-config [WORD|ftp|running-config|tftp] . . . . . . . . . . . . . . . . . . . . . .
copy tftp [flash|running-config|sca|startup-config] . . . . . . . . . . . . . . . . . . . . . . .
copy xmodem [flash|running-config|startup-config] . . . . . . . . . . . . . . . . . . . . . .
copy ymodem [flash|running-config|startup-config] . . . . . . . . . . . . . . . . . . . . . .
copy ymodem flash <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
erase [WORD|startup-config] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
erase startup-config <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force alarm [acknowledge|clear|reset|resync] . . . . . . . . . . . . . . . . . . . . . . . . . .
force alarm acknowledge <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force alarm clear <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force alarm reset <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force alarm resync <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force auto-upgrade [abort|reset-config-cache|start] . . . . . . . . . . . . . . . . . . . . . .
force export [diagnostics|system-event-log] . . . . . . . . . . . . . . . . . . . . . . . . . . .
force export diagnostics <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force export system-event-log new-events . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force export system-event-log to syslog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force logoff <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force manual-switch erps east <shelf/slot/id> . . . . . . . . . . . . . . . . . . . . . . . . . .
force manual-switch erps west <shelf/slot/id> . . . . . . . . . . . . . . . . . . . . . . . . . .
force manual-switch protection-group <shelf/slot> . . . . . . . . . . . . . . . . . . . . . .
force manual-switch redundancy <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . .
force manual-switch system-timing <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force peer default ip dhcp-client release interface ppp-group <shelf/slot/group>
force peer default ip dhcp-client renew interface ppp-group <shelf/slot/group>
force remote-download <remote-index> [application|boot] . . . . . . . . . . . . . . . .
force restart ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-126
2-127
2-128
2-129
2-130
2-131
2-132
2-133
2-134
2-136
2-137
2-138
2-139
2-140
2-141
2-142
2-143
2-144
2-145
2-147
2-148
2-149
2-151
2-153
2-155
2-157
2-158
2-159
2-160
2-161
2-162
2-163
2-164
2-165
2-166
2-167
2-168
2-169
2-170
2-171
2-172
2-173
2-174
2-175
2-176
2-177
2-178

6TANV57CLI-35A

Contents

force retrain [fast|full] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-179


force retrain fast [<shelf/slot/port>|<shelf/slot>] . . . . . . . . . . . . . . . . . . . . . . . . . 2-180
force retrain full [<shelf/slot/port>|<shelf/slot>] . . . . . . . . . . . . . . . . . . . . . . . . . 2-181
force scr [all|modules] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-182
force sip registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-183
force sip registration <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-184
force sip registration <shelf/slot> <Txx> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-185
force sip registration <shelf/slot> <Txx> WORD . . . . . . . . . . . . . . . . . . . . . . . . 2-186
force ssh-keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-187
logout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-188
ping A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-189
ping A.B.C.D repeat <1-1000000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-190
ping A.B.C.D repeat <1-1000000> timeout <1000-8000> . . . . . . . . . . . . . . . . . 2-192
ping A.B.C.D repeat <1-1000000> timeout <1000-8000> size <0-1448> . . . . . 2-194
ping atm <shelf/slot/port.sub> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-196
ping atm <shelf/slot/port.sub> count <1-1000000> . . . . . . . . . . . . . . . . . . . . . . 2-197
ping atm <shelf/slot/port.sub> count <1-1000000> destination-llid HEX:32 source-llid
HEX:32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-198
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> . . 2-199
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-200
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-202
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-204
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> . . . . . . . . . . . . . 2-206
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> 2208
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-210
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-212
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible validate-data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-214
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible validate-data verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-215
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-217
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD validate-data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-218
ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data

6TANV57CLI-35A

xi

Total Access/NetVanta Carrier CLI Dictionary

WORD validate-data verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-219


ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> count <11024> priority <0-7> size <46-1500> timeout <1000-60000> interval <100-5000> data
WORD verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-221
ping ip-host WORD <shelf/slot> A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-222
ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000> . . . . . . . . . . . . . 2-223
ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000> timeout <1000-5000>
2-224
ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000> timeout <1000-5000>
size <0-1448> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-225
prompt-detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-226
reload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-227
reload [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-229
show [aaa|alarm|arp|clock|default-config|door|dynamic-counter|evc|evc-map|eventlog|ez-provisioning|flash|interfaces|mevc|output-errors|policer|protectiongroup|running-config|shaper|shdsl|sntp|startup-config|system|system-managementevc|system-timing|temperature-sensor|users|version|vlan] . . . . . . . . . . . . . . . 2-230
show aaa [local|radius|tacacs+] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-236
show alarm log [<shelf/slot>|ascending|descending] . . . . . . . . . . . . . . . . . . . . 2-237
show alarm log <shelf/slot> [ascending|descending] . . . . . . . . . . . . . . . . . . . . 2-239
show arp <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-241
show auto-upgrade module-status <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . 2-242
show auto-upgrade module-status <shelf/slot> realtime . . . . . . . . . . . . . . . . . . 2-243
show auto-upgrade shelf-status [<shelf>|realtime] . . . . . . . . . . . . . . . . . . . . . . 2-244
show auto-upgrade shelf-status <shelf> realtime . . . . . . . . . . . . . . . . . . . . . . . 2-245
show clock detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-246
show copy file-server flash [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . 2-247
show copy file-server flash [<shelf/slot>|<remote-index>] realtime . . . . . . . . . . 2-248
show dynamic-counter <shelf/slot/index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-250
show efm-group [<shelf/slot>|<shelf>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-251
show efm-link [<shelf/slot>|<shelf>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-252
show ethernet cfm [association|config-errors|default-domain|domain|stack|traceroutecache] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-253
show ethernet cfm association [WORD|detail|incomplete] . . . . . . . . . . . . . . . . 2-255
show ethernet cfm association WORD [WORD|detail] . . . . . . . . . . . . . . . . . . . 2-257
show ethernet cfm association WORD WORD detail . . . . . . . . . . . . . . . . . . . . 2-259
show ethernet cfm config-errors interface efm-group <shelf/slot/group> . . . . . 2-260
show ethernet cfm config-errors interface ethernet <shelf/slot/port> . . . . . . . . . 2-261
show ethernet cfm config-errors interface gigabit-ethernet <shelf/slot/port> . . . 2-262
show ethernet cfm config-errors vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . 2-263
show ethernet cfm default-domain component-id <1-n> . . . . . . . . . . . . . . . . . . 2-264
show ethernet cfm default-domain component-id <1-n> vlan <1-4094> . . . . . . 2-265
show ethernet cfm default-domain vlan <1-4094> . . . . . . . . . . . . . . . . . . . . . . . 2-266
show ethernet cfm domain [WORD|detail|incomplete] . . . . . . . . . . . . . . . . . . . 2-267
show ethernet cfm domain WORD detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-268
show ethernet cfm mep [local|remote] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-269
show ethernet cfm mep local [detail|down|fault|statistics|up] . . . . . . . . . . . . . . 2-270
show ethernet cfm mep local association WORD [detail|fault|statistics] . . . . . . 2-272

xii

6TANV57CLI-35A

Contents

show ethernet cfm mep local domain WORD [detail|fault|statistics] . . . . . . . . . 2-274


show ethernet cfm mep local down [detail|fault|statistics] . . . . . . . . . . . . . . . . . 2-275
show ethernet cfm mep local interface efm-group [<shelf/slot/port>|WORD] . . 2-276
show ethernet cfm mep local interface efm-group [<shelf/slot/port>|WORD] detail 2277
show ethernet cfm mep local interface efm-group [<shelf/slot/port>|WORD] fault . 2278
show ethernet cfm mep local interface efm-group [<shelf/slot/port>|WORD] statistics
2-279
show ethernet cfm mep local interface ethernet <shelf/slot/port> [detail|fault|statistics]
2-280
show ethernet cfm mep local interface gigabit-ethernet <shelf/slot/port>
[detail|fault|statistics] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-281
show ethernet cfm mep local interface ppp-group <shelf/slot/group>
[detail|fault|statistics] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-282
show ethernet cfm mep local level <0-7> [detail|fault|statistics] . . . . . . . . . . . . 2-283
show ethernet cfm mep local mep-id <1-8191> [detail|fault|statistics] . . . . . . . 2-284
show ethernet cfm mep local up [detail|fault|statistics] . . . . . . . . . . . . . . . . . . . 2-285
show ethernet cfm mep local vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . . . 2-286
show ethernet cfm mep local vlan <1-4094> [detail|fault|statistics] . . . . . . . . . . 2-287
show ethernet cfm mep local vlan none [detail|fault|statistics] . . . . . . . . . . . . . 2-288
show ethernet cfm mep remote [detail|down] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-289
show ethernet cfm mep remote association WORD . . . . . . . . . . . . . . . . . . . . . 2-291
show ethernet cfm mep remote association WORD detail . . . . . . . . . . . . . . . . 2-292
show ethernet cfm mep remote domain WORD . . . . . . . . . . . . . . . . . . . . . . . . 2-294
show ethernet cfm mep remote domain WORD detail . . . . . . . . . . . . . . . . . . . 2-295
show ethernet cfm mep remote down detail . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-297
show ethernet cfm mep remote interface efm-group [<shelf/slot/port>|WORD] 2-298
show ethernet cfm mep remote interface efm-group [<shelf/slot/port>|WORD] detail
2-300
show ethernet cfm mep remote interface ethernet <shelf/slot/port> . . . . . . . . . 2-302
show ethernet cfm mep remote interface ethernet <shelf/slot/port> detail . . . . 2-304
show ethernet cfm mep remote interface gigabit-ethernet <shelf/slot/port> . . . 2-306
show ethernet cfm mep remote interface gigabit-ethernet <shelf/slot/port> detail . 2308
show ethernet cfm mep remote interface ppp-group <shelf/slot/group> . . . . . . 2-310
show ethernet cfm mep remote interface ppp-group <shelf/slot/group> detail . 2-311
show ethernet cfm mep remote level <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-313
show ethernet cfm mep remote level <0-7> detail . . . . . . . . . . . . . . . . . . . . . . . 2-314
show ethernet cfm mep remote local-mep <1-8191> . . . . . . . . . . . . . . . . . . . . 2-315
show ethernet cfm mep remote local-mep <1-8191> detail . . . . . . . . . . . . . . . . 2-316
show ethernet cfm mep remote remote-mep <1-8191> . . . . . . . . . . . . . . . . . . 2-317
show ethernet cfm mep remote remote-mep <1-8191> detail . . . . . . . . . . . . . . 2-318
show ethernet cfm mep remote vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . 2-319
show ethernet cfm mep remote vlan <1-4094> detail . . . . . . . . . . . . . . . . . . . . 2-320
show ethernet cfm mep remote vlan none detail . . . . . . . . . . . . . . . . . . . . . . . . 2-322
show ethernet cfm stack down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-323
show ethernet cfm stack interface efm-group <shelf/slot/group> . . . . . . . . . . . 2-324

6TANV57CLI-35A

xiii

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm stack interface ethernet <shelf/slot/port> . . . . . . . . . . . . . . 2-325


show ethernet cfm stack interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . 2-326
show ethernet cfm stack interface ppp-group <shelf/slot/group> . . . . . . . . . . . 2-327
show ethernet cfm stack level <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-328
show ethernet cfm stack vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . . . . . . . 2-329
show ethernet cfm traceroute-cache association WORD . . . . . . . . . . . . . . . . . 2-330
show ethernet cfm traceroute-cache domain WORD . . . . . . . . . . . . . . . . . . . . 2-331
show ethernet cfm traceroute-cache interface efm-group [<shelf/slot/group>|WORD]
2-332
show ethernet cfm traceroute-cache interface ethernet <shelf/slot/port> . . . . . 2-333
show ethernet cfm traceroute-cache interface gigabit-ethernet <shelf/slot/port> 2-334
show ethernet cfm traceroute-cache level <0-7> . . . . . . . . . . . . . . . . . . . . . . . . 2-336
show ethernet cfm traceroute-cache local-mep-id <1-8191> . . . . . . . . . . . . . . 2-337
show ethernet cfm traceroute-cache vlan [<1-4094>|none] . . . . . . . . . . . . . . . 2-338
show ethernet evc-advertisement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-340
show ethernet evc-advertisement interface [efm-group|ethernet|gigabitethernet|muxponder-highspeed|muxponder-midspeed] . . . . . . . . . . . . . . . . . . 2-341
show ethernet evc-advertisement interface efm-group <shelf/slot/group> . . . . 2-342
show ethernet evc-advertisement interface ethernet <shelf/slot/port> . . . . . . . 2-343
show ethernet evc-advertisement interface gigabit-ethernet <shelf/slot/port> . 2-344
show ethernet evc-advertisement interface muxponder-highspeed <shelf/slot/port> .
2-345
show ethernet evc-advertisement interface muxponder-midspeed <shelf/slot/port> 2346
show evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-347
show evc-map WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-348
show evc-map WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-349
show event-history <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-351
show event-log detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-352
show event-log statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-353
show event-log type [account|date|login|module|network|sca|security|snmp|upgrade]
2-354
show event-log type account detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-356
show event-log type date detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-357
show event-log type login detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-358
show event-log type module detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-359
show event-log type network detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-360
show event-log type sca detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-361
show event-log type security detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-362
show event-log type snmp detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-363
show event-log type upgrade detail <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-364
show fan <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-365
show file WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-366
show interfaces [adsl|atm|backplane|e1|efm-group|efm-link|efmport|erps|ethernet|frame-relay|fxs|gigabit-ethernet|gpon|hdsl2|hdsl4|laggroup|muxponder-highspeed|muxponder-midspeed|packet-timing|ppp-group|ppplink|processor-ethernet|pseudowire|rf-video|shdsl|t1|t3|ten-gigabit-ethernet|vdsl] . 2367

xiv

6TANV57CLI-35A

Contents

show interfaces adsl <shelf/slot/port> bit-allocation-table [downstream|upstream] . 2370


show interfaces adsl <shelf/slot/port> circuit [capabilities|inventory] . . . . . . . . . 2-371
show interfaces adsl <shelf/slot/port> performance-statistics [15-minute|24-hour] . 2372
show interfaces adsl <shelf/slot/port> performance-statistics 15-minute [<196>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-373
show interfaces adsl <shelf/slot/port> performance-statistics 24-hour [<1-7>|realtime]
2-374
show interfaces adsl <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . . . . 2-375
show interfaces adsl <shelf/slot/port> snr-table upstream . . . . . . . . . . . . . . . . . 2-376
show interfaces atm <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-377
show interfaces atm <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . . . . 2-378
show interfaces atm-group <shelf/slot/group> legacy-atm . . . . . . . . . . . . . . . . 2-379
show interfaces atm-group legacy-atm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-380
show interfaces backplane <shelf/slot/port> performance-statistics [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-381
show interfaces backplane <shelf/slot/port> performance-statistics 15-minute <1-96>
2-382
show interfaces backplane <shelf/slot/port> performance-statistics 24-hour <1-7> 2383
show interfaces backplane <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . 2-384
show interfaces e1 <shelf/slot/port> performance-statistics [15-minute|24-hour] 2-385
show interfaces e1 <shelf/slot/port> performance-statistics 15-minute <1-96> . 2-386
show interfaces e1 <shelf/slot/port> performance-statistics 24-hour <1-7> . . . 2-388
show interfaces e1 <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . . . . . 2-390
show interfaces efm-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . . . . 2-391
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 15minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-392
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 15minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-393
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 15minute realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-394
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 24-hour
2-395
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 24-hour
<1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-396
show interfaces efm-group [<shelf/slot/group>|WORD] performance-statistics 24-hour
realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-397
show interfaces efm-group [<shelf/slot/group>|WORD] realtime . . . . . . . . . . . . 2-398
show interfaces efm-group [<shelf/slot/group>|WORD] subtended-host . . . . . . 2-399
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . 2-400
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-401
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-403
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-405
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performance-

6TANV57CLI-35A

xv

Total Access/NetVanta Carrier CLI Dictionary

statistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-406


show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-408
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-410
show interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] realtime . . . 2-411
show interfaces efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-412
show interfaces efm-port <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . 2-413
show interfaces erps <shelf/slot/ring> [performance-statistics|realtime] . . . . . . 2-414
show interfaces erps <shelf/slot/ring> performance-statistics [15-minute|24-hour] . 2415
show interfaces erps <shelf/slot/ring> performance-statistics 15-minute <0-96> 2-416
show interfaces erps <shelf/slot/ring> performance-statistics 24-hour <0-7> . . 2-417
show interfaces ethernet <shelf/slot/port> [realtime|subtended-host] . . . . . . . . 2-418
show interfaces ethernet <shelf/slot/port> performance-statistics [15-minute|24-hour]
2-419
show interfaces ethernet <shelf/slot/port> performance-statistics 15-minute <1-96> .
2-420
show interfaces ethernet <shelf/slot/port> performance-statistics 24-hour <1-7> . . 2421
show interfaces frame-relay [<shelf/slot/group> |dlci] . . . . . . . . . . . . . . . . . . . . 2-422
show interfaces frame-relay <shelf/slot/group> dlci . . . . . . . . . . . . . . . . . . . . . 2-423
show interfaces frame-relay <shelf/slot/group> dlci <16-991> performance-statistics
[15-minutes|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-424
show interfaces frame-relay <shelf/slot/group> dlci <16-991> performance-statistics
15-minutes [<1-96>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-425
show interfaces frame-relay <shelf/slot/group> dlci <16-991> performance-statistics
24-hour [<1-7>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-426
show interfaces frame-relay <shelf/slot/group> dlci <16-991> realtime . . . . . . 2-427
show interfaces frame-relay <shelf/slot/group> performance-statistics [15-minutes|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-428
show interfaces frame-relay <shelf/slot/group> performance-statistics 15-minutes [<196>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-429
show interfaces frame-relay <shelf/slot/group> performance-statistics 24-hour [<17>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-430
show interfaces frame-relay <shelf/slot/group> realtime . . . . . . . . . . . . . . . . . 2-431
show interfaces fxs [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . . . . . . . 2-432
show interfaces fxs [<shelf/slot/port>|<remote-index>] line-test . . . . . . . . . . . . 2-433
show interfaces fxs [<shelf/slot/port>|<remote-index>] realtime . . . . . . . . . . . . 2-434
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] . . . . . . . . . 2-435
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-436
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] performancestatistics 15-minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-437
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-438
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] performancestatistics 24-hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-439
show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] pluggable 2-440

xvi

6TANV57CLI-35A

Contents

show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] realtime . . 2-441


show interfaces gigabit-ethernet [<shelf/slot/port>|<remote-index>] subtended-host .
2-443
show interfaces gpon <shelf/slot/port> performance-statistics [15-minute|24-hour] 2444
show interfaces gpon <shelf/slot/port> performance-statistics 15-minute <1-96> . . 2445
show interfaces gpon <shelf/slot/port> performance-statistics 24-hour <1-7> . 2-446
show interfaces gpon <shelf/slot/port> subtended-host . . . . . . . . . . . . . . . . . . 2-447
show interfaces hdsl2 <shelf/slot/port> performance-statistics [15-minute|24-hour] 2448
show interfaces hdsl2 <shelf/slot/port> performance-statistics 15-minute <1-96> . 2449
show interfaces hdsl2 <shelf/slot/port> performance-statistics 24-hour <1-7> . 2-450
show interfaces hdsl2 <shelf/slot/port> splice-detect [24-hour|histogram] . . . . 2-451
show interfaces hdsl2 <shelf/slot/port> splice-detect 24-hour <1-14> . . . . . . . . 2-452
show interfaces hdsl4 <shelf/slot/port> performance-statistics [15-minute|24-hour] 2453
show interfaces hdsl4 <shelf/slot/port> performance-statistics 15-minute <1-96> . 2454
show interfaces hdsl4 <shelf/slot/port> performance-statistics 24-hour <1-7> . 2-456
show interfaces hdsl4 <shelf/slot/port> splice-detect [24-hour|histogram] . . . . 2-458
show interfaces hdsl4 <shelf/slot/port> splice-detect 24-hour <1-14> . . . . . . . . 2-459
show interfaces ip-host WORD [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . 2-460
show interfaces ip-host slot <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-461
show interfaces lag-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-462
show interfaces lag-group <shelf/slot/group> realtime . . . . . . . . . . . . . . . . . . . 2-463
show interfaces muxponder-highspeed {<shelf/slot/port> } . . . . . . . . . . . . . . . . 2-464
show interfaces muxponder-highspeed <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-465
show interfaces muxponder-highspeed <shelf/slot/port> performance-statistics 15minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-466
show interfaces muxponder-highspeed <shelf/slot/port> performance-statistics 24hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-467
show interfaces muxponder-highspeed <shelf/slot/port> pluggable . . . . . . . . . 2-468
show interfaces muxponder-highspeed <shelf/slot/port> realtime . . . . . . . . . . 2-469
show interfaces muxponder-highspeed <shelf/slot/port> subtended-host . . . . 2-470
show interfaces muxponder-midspeed {<shelf/slot/port> } . . . . . . . . . . . . . . . . 2-471
show interfaces muxponder-midspeed <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-472
show interfaces muxponder-midspeed <shelf/slot/port> performance-statistics 15minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-473
show interfaces muxponder-midspeed <shelf/slot/port> performance-statistics 24-hour
<1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-474
show interfaces muxponder-midspeed <shelf/slot/port> pluggable . . . . . . . . . 2-475
show interfaces muxponder-midspeed <shelf/slot/port> realtime . . . . . . . . . . . 2-476
show interfaces muxponder-midspeed <shelf/slot/port> subtended-host . . . . . 2-477
show interfaces packet-timing <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-478
show interfaces ppp-group <shelf/slot/group> performance-statistics [15-minute|24-

6TANV57CLI-35A

xvii

Total Access/NetVanta Carrier CLI Dictionary

hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-479
show interfaces ppp-group <shelf/slot/group> performance-statistics 15-minute [<196>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-480
show interfaces ppp-group <shelf/slot/group> performance-statistics 24-hour [<17>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-481
show interfaces ppp-group <shelf/slot/group> realtime . . . . . . . . . . . . . . . . . . . 2-482
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . 2-484
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-485
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-486
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-487
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-488
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-489
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-490
show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/port:chan>] realtime . . . 2-491
show interfaces pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remote-index>] . . 2-493
show interfaces pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remote-index>]
performance-statistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-494
show interfaces pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remote-index>]
performance-statistics 15-minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-495
show interfaces pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remote-index>]
performance-statistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-496
show interfaces pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remote-index>]
performance-statistics 24-hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-497
show interfaces rf-video <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-498
show interfaces shdsl <shelf/slot/port> [circuit|realtime] . . . . . . . . . . . . . . . . . . 2-499
show interfaces shdsl <shelf/slot/port> circuit inventory . . . . . . . . . . . . . . . . . . 2-501
show interfaces shdsl <shelf/slot/port> circuit performance-statistics [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-502
show interfaces shdsl <shelf/slot/port> circuit performance-statistics 15-minute <1-96>
2-504
show interfaces shdsl <shelf/slot/port> circuit performance-statistics 24-hour <1-7> .
2-506
show interfaces shdsl <shelf/slot/port> performance-statistics [15-minute|24-hour] 2508
show interfaces shdsl <shelf/slot/port> performance-statistics 15-minute <1-96> . 2509
show interfaces shdsl <shelf/slot/port> performance-statistics 24-hour <1-7> . 2-511
show interfaces shdsl <shelf/slot/port> splice-detect 24-hour . . . . . . . . . . . . . . 2-513
show interfaces shdsl <shelf/slot/port> splice-detect 24-hour <1-7> . . . . . . . . . 2-515
show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . . . . 2-517
show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performance-statistics 15minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-519
show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performance-statistics 15-

xviii

6TANV57CLI-35A

Contents

minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-521


show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performance-statistics 24hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-523
show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performance-statistics 24hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-525
show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] realtime . . . . . . . . 2-527
show interfaces t3 <shelf/slot/port> performance-statistics [15-minute|24-hour] 2-528
show interfaces t3 <shelf/slot/port> performance-statistics 15-minute <1-96> . 2-529
show interfaces t3 <shelf/slot/port> performance-statistics 24-hour <1-7> . . . . 2-531
show interfaces t3 <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-533
show interfaces ten-gigabit-ethernet <shelf/slot/port> [pluggable|realtime] . . . . 2-534
show interfaces ten-gigabit-ethernet <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-535
show interfaces ten-gigabit-ethernet <shelf/slot/port> performance-statistics 15-minute
<1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-536
show interfaces ten-gigabit-ethernet <shelf/slot/port> performance-statistics 24-hour
<1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-537
show interfaces vdsl <shelf/slot/port> band-table [downstream|upstream] . . . . 2-538
show interfaces vdsl <shelf/slot/port> bit-allocation-table [downstream|upstream] . 2539
show interfaces vdsl <shelf/slot/port> performance-statistics [15-minute|24-hour] . 2540
show interfaces vdsl <shelf/slot/port> performance-statistics 15-minute [<196>|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-541
show interfaces vdsl <shelf/slot/port> performance-statistics 15-minute <1-96>
realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-543
show interfaces vdsl <shelf/slot/port> performance-statistics 24-hour [<1-7>|realtime]
2-545
show interfaces vdsl <shelf/slot/port> performance-statistics 24-hour <1-7> realtime
2-547
show interfaces vdsl <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . . . . . . 2-549
show interfaces vdsl <shelf/slot/port> snr-table upstream . . . . . . . . . . . . . . . . . 2-551
show ip [access-lists|ntp|route] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-552
show ip access-lists WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-554
show ip igmp [evc|evc-map|groups|interface] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-555
show ip igmp evc WORD <shelf/slot> performance-statistics [15-minute|24-hour] . 2556
show ip igmp evc WORD <shelf/slot> performance-statistics 15-minute <1-96> 2-557
show ip igmp evc WORD <shelf/slot> performance-statistics 24-hour <1-7> . . 2-559
show ip igmp evc WORD <shelf/slot> realtime . . . . . . . . . . . . . . . . . . . . . . . . . 2-561
show ip igmp evc WORD performance-statistics [15-minute|24-hour] . . . . . . . 2-562
show ip igmp evc WORD performance-statistics 15-minute <1-96> . . . . . . . . . 2-563
show ip igmp evc WORD performance-statistics 24-hour <1-7> . . . . . . . . . . . . 2-565
show ip igmp evc-map WORD <shelf/slot> performance-statistics [15-minute|24-hour]
2-567
show ip igmp evc-map WORD <shelf/slot> performance-statistics 15-minute <1-96>
2-568
show ip igmp evc-map WORD <shelf/slot> performance-statistics 24-hour <1-7> . 2570

6TANV57CLI-35A

xix

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc-map WORD <shelf/slot> realtime . . . . . . . . . . . . . . . . . . . . . 2-572


show ip igmp groups <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-573
show ip igmp groups <shelf/slot> A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-574
show ip igmp interface [adsl|backplane|gigabit-ethernet|ten-gigabit-ethernet|vdsl] . 2575
show ip igmp interface adsl <shelf/slot/port> performance-statistics [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-577
show ip igmp interface adsl <shelf/slot/port> performance-statistics 15-minute <1-96>
2-578
show ip igmp interface adsl <shelf/slot/port> performance-statistics 24-hour <1-96> .
2-580
show ip igmp interface adsl <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . 2-582
show ip igmp interface backplane <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-583
show ip igmp interface backplane <shelf/slot/port> performance-statistics 15-minute
<1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-584
show ip igmp interface backplane <shelf/slot/port> performance-statistics 24-hour <17> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-586
show ip igmp interface backplane <shelf/slot/port> realtime . . . . . . . . . . . . . . . 2-588
show ip igmp interface gigabit-ethernet <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-589
show ip igmp interface gigabit-ethernet <shelf/slot/port> performance-statistics 15minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-590
show ip igmp interface gigabit-ethernet <shelf/slot/port> performance-statistics 24hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-592
show ip igmp interface gigabit-ethernet <shelf/slot/port> realtime . . . . . . . . . . . 2-594
show ip igmp interface ten-gigabit-ethernet <shelf/slot/port> performance-statistics
[15-minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-595
show ip igmp interface ten-gigabit-ethernet <shelf/slot/port> performance-statistics 15minute <1-96> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-596
show ip igmp interface ten-gigabit-ethernet <shelf/slot/port> performance-statistics 24hour <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-598
show ip igmp interface ten-gigabit-ethernet <shelf/slot/port> realtime . . . . . . . 2-600
show ip igmp interface vdsl <shelf/slot/port> performance-statistics [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-601
show ip igmp interface vdsl <shelf/slot/port> performance-statistics 15-minute <1-96>
2-602
show ip igmp interface vdsl <shelf/slot/port> performance-statistics 24-hour <1-7> 2604
show ip igmp interface vdsl <shelf/slot/port> realtime . . . . . . . . . . . . . . . . . . . . 2-606
show ip ntp associations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-607
show lacp [<shelf/slot>|system-id] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-609
show lacp <shelf/slot> [counters|states|summary] . . . . . . . . . . . . . . . . . . . . . . 2-610
show lacp interface gigabit-ethernet <shelf/slot/port> [states|summary] . . . . . . 2-611
show lacp interface lag-group <shelf/slot/group> [states|summary] . . . . . . . . . 2-612
show lacp interface ten-gigabit-ethernet <shelf/slot/port> [states|summary] . . . 2-613
show line console <0> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-614
show mac [address-table|limits] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-615
show mac address-table <shelf/slot> [aging-time|count|dynamic|multicast|static] . 2-

xx

6TANV57CLI-35A

Contents

617
show mac address-table <shelf/slot> dynamic s-tag <1-4094> . . . . . . . . . . . . . 2-618
show mac address-table <shelf/slot> evc WORD . . . . . . . . . . . . . . . . . . . . . . . 2-619
show mac address-table <shelf/slot> s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . 2-620
show mac address-table <shelf/slot> static s-tag <1-4094> . . . . . . . . . . . . . . . 2-621
show mac address-table dynamic interface backplane <shelf/slot/port> . . . . . . 2-622
show mac address-table dynamic interface gigabit-ethernet <shelf/slot/port> . 2-623
show mac address-table dynamic interface muxponder-highspeed <shelf/slot/port> .
2-624
show mac address-table dynamic interface muxponder-midspeed <shelf/slot/port> 2625
show mac address-table dynamic interface ten-gigabit-ethernet <shelf/slot/port> . 2626
show mac address-table interface backplane <shelf/slot/port> . . . . . . . . . . . . . 2-627
show mac address-table interface gigabit-ethernet <shelf/slot/port> . . . . . . . . 2-628
show mac address-table interface muxponder-highspeed <shelf/slot/port> . . . 2-629
show mac address-table interface muxponder-midspeed <shelf/slot/port> . . . . 2-630
show mac address-table interface ten-gigabit-ethernet <shelf/slot/port> . . . . . 2-631
show mac address-table static interface backplane <shelf/slot/port> . . . . . . . . 2-632
show mac address-table static interface gigabit-ethernet <shelf/slot/port> . . . . 2-633
show mac address-table static interface muxponder-highspeed <shelf/slot/port> . 2634
show mac address-table static interface muxponder-midspeed <shelf/slot/port> . . 2635
show mac address-table static interface ten-gigabit-ethernet <shelf/slot/port> . 2-636
show menu [configuration|status] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-637
show menu performance-statistics e1 <shelf/slot/port> [15-minute|24-hour] . . 2-639
show menu performance-statistics ethernet <shelf/slot/port> [15-minute|24-hour] . 2640
show menu performance-statistics gigabit-ethernet <shelf/slot/port> [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-642
show menu performance-statistics hdsl2 <shelf/slot/port> [15-minute|24-hour] 2-644
show menu performance-statistics hdsl4 <shelf/slot/port> [15-minute|24-hour] 2-645
show menu performance-statistics shdsl <shelf/slot/port> [15-minute|24-hour] 2-646
show menu performance-statistics t1 [<shelf/slot/port>|<shelf/slot/port:chan>] 15minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-648
show menu performance-statistics t1 [<shelf/slot/port>|<shelf/slot/port:chan>] 24-hour
2-649
show menu performance-statistics t3 <shelf/slot/port> [15-minute|24-hour] . . . 2-650
show menu provisioning e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-651
show menu provisioning ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-652
show menu provisioning gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . 2-653
show menu provisioning hdsl2 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-654
show menu provisioning hdsl4 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-655
show menu provisioning shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-656
show menu provisioning t1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-658
show menu provisioning t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-659
show menu status detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-660

6TANV57CLI-35A

xxi

Total Access/NetVanta Carrier CLI Dictionary

show mevc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-662


show mevc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-663
show muxponder-ethernet <shelf/slot> qos [cos-map|untagged] . . . . . . . . . . . 2-664
show node-information statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-665
show peer default ip dhcp-client lease interface ppp-group <shelf/slot/group> . 2-666
show policer WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-667
show policer WORD performance-statistics [15-minute|24-hour] . . . . . . . . . . . 2-668
show policer WORD performance-statistics 15-minute <1-96> . . . . . . . . . . . . . 2-670
show policer WORD performance-statistics 24-hour <1-7> . . . . . . . . . . . . . . . 2-672
show port-auth interface atm <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-674
show port-auth interface efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-675
show port-auth statistics interface atm <shelf/slot/port> . . . . . . . . . . . . . . . . . . 2-676
show port-auth statistics interface efm-port <shelf/slot/port> . . . . . . . . . . . . . . 2-677
show ppp-group [<shelf/slot>|<shelf>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-678
show ppp-link [<shelf/slot>|<shelf>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-681
show probe responder twamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-682
show probe responder twamp verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-683
show processes summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-684
show processes summary <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-686
show protection-group [<shelf/group>|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . 2-688
show qos [cos-map|untagged] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-689
show queue interfaces [efm-group|ethernet|gigabit-ethernet|muxponderhighspeed|muxponder-midspeed|ten-gigabit-ethernet] . . . . . . . . . . . . . . . . . . 2-690
show queue interfaces efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . 2-692
show queue interfaces efm-group <shelf/slot/group> <0-n> . . . . . . . . . . . . . . . 2-693
show queue interfaces ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . 2-694
show queue interfaces ethernet <shelf/slot/port> <0-n> . . . . . . . . . . . . . . . . . . 2-696
show queue interfaces gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . 2-698
show queue interfaces gigabit-ethernet <shelf/slot/port> <0-n> . . . . . . . . . . . . 2-700
show queue interfaces muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . 2-702
show queue interfaces muxponder-highspeed <shelf/slot/port> <0-n> . . . . . . . 2-703
show queue interfaces muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . 2-704
show queue interfaces muxponder-midspeed <shelf/slot/port> <0-n> . . . . . . . 2-706
show queue interfaces ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . 2-708
show queue interfaces ten-gigabit-ethernet <shelf/slot/port> <0-n> . . . . . . . . . 2-709
show redundancy <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-710
show remote-devices <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-711
show ring-generator <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-712
show running-config [arp|auto-upgrade|counter-profile|dynamic-counter|evc|evcmap|event-log-export|fan|mevc|muxponder-ethernet|policer|powershedding|protectiongroup|queue|redundancy|sca|security|shaper|slot|system|system-alarm|systemmanagement-evc|system-timing|temperature-sensor|tl1|verbose] . . . . . . . . . . 2-713
show running-config arp [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . 2-716
show running-config arp <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . . . . . . . . 2-717
show running-config auto-upgrade verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-718
show running-config counter-profile [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . 2-719

xxii

6TANV57CLI-35A

Contents

show running-config counter-profile <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-720


show running-config dynamic-counter [<shelf/slot>|verbose] . . . . . . . . . . . . . . 2-721
show running-config dynamic-counter <shelf/slot> verbose . . . . . . . . . . . . . . . 2-722
show running-config ethernet cfm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-723
show running-config ethernet cfm verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-724
show running-config evc [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-726
show running-config evc WORD verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-728
show running-config evc-map [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . . . 2-729
show running-config evc-map WORD [<shelf/slot>|verbose] . . . . . . . . . . . . . . 2-731
show running-config evc-map WORD <shelf/slot> verbose . . . . . . . . . . . . . . . 2-732
show running-config event-log-export verbose . . . . . . . . . . . . . . . . . . . . . . . . . 2-734
show running-config fan [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . 2-735
show running-config fan <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . . . . . . . . 2-736
show running-config interface [adsl|atm|e1|efm-group|efm-link|efmport|erps|ethernet|frame-relay|fxs|gigabit-ethernet|gpon|hdsl2|hdsl4|ip-host|laggroup|muxponder-highspeed|muxponder-midspeed|packet-timing|ppp-group|rfvideo|shdsl|t1|t3|ten-gigabit-ethernet|vdsl] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-737
show running-config interface adsl [[<shelf/slot>|<shelf/slot/port>]|verbose] . . 2-740
show running-config interface adsl [<shelf/slot>|<shelf/slot/port>] verbose . . . 2-741
show running-config interface atm [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . 2-742
show running-config interface atm <shelf/slot> verbose . . . . . . . . . . . . . . . . . . 2-743
show running-config interface atm-group <shelf/slot/group> legacy-atm . . . . . 2-744
show running-config interface atm-group <shelf/slot/group> legacy-atm verbose . 2745
show running-config interface atm-group legacy-atm . . . . . . . . . . . . . . . . . . . . 2-746
show running-config interface atm-group legacy-atm verbose . . . . . . . . . . . . . 2-747
show running-config interface e1 [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . 2-748
show running-config interface e1 <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . 2-749
show running-config interface efm-group [<shelf/slot>|verbose] . . . . . . . . . . . . 2-750
show running-config interface efm-group <shelf/slot> verbose . . . . . . . . . . . . . 2-751
show running-config interface efm-link [<shelf/slot>|verbose] . . . . . . . . . . . . . . 2-752
show running-config interface efm-link <shelf/slot> verbose . . . . . . . . . . . . . . . 2-753
show running-config interface efm-port [<shelf/slot>|verbose] . . . . . . . . . . . . . 2-754
show running-config interface efm-port <shelf/slot> verbose . . . . . . . . . . . . . . 2-755
show running-config interface erps [<shelf/slot/ring>|verbose] . . . . . . . . . . . . . 2-756
show running-config interface erps <shelf/slot/ring> verbose . . . . . . . . . . . . . . 2-757
show running-config interface ethernet [<shelf/slot>|verbose] . . . . . . . . . . . . . 2-758
show running-config interface ethernet <shelf/slot> verbose . . . . . . . . . . . . . . 2-759
show running-config interface frame-relay [<shelf/slot/group>|dlci|verbose] . . . 2-760
show running-config interface frame-relay <shelf/slot/group> [dlci|verbose] . . . 2-761
show running-config interface frame-relay <shelf/slot/group> dlci <16-991> . . 2-762
show running-config interface frame-relay <shelf/slot/group> dlci <16-991> verbose
2-763
show running-config interface frame-relay dlci verbose . . . . . . . . . . . . . . . . . . 2-764
show running-config interface fxs [[<shelf/slot/port>|<remote-index>]|verbose] 2-765
show running-config interface fxs [<shelf/slot/port>|<remote-index>] verbose . 2-766
show running-config interface gigabit-ethernet [[<shelf/slot>|<shelf/slot/port>|<remoteindex>]|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-767

6TANV57CLI-35A

xxiii

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface gigabit-ethernet [<shelf/slot>|<shelf/slot/port>|<remoteindex>] verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-768


show running-config interface gpon [<shelf/slot/port>|verbose] . . . . . . . . . . . . 2-770
show running-config interface gpon <shelf/slot/port> verbose . . . . . . . . . . . . . 2-771
show running-config interface hdsl2 [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . 2-772
show running-config interface hdsl2 <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-773
show running-config interface hdsl4 [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . 2-774
show running-config interface hdsl4 <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-775
show running-config interface ip-host WORD [<shelf/slot>|<remote-index>] . . 2-776
show running-config interface ip-host WORD [<shelf/slot>|<remote-index>] verbose
2-777
show running-config interface ip-host verbose . . . . . . . . . . . . . . . . . . . . . . . . . 2-778
show running-config interface lag-group [<shelf/slot>|verbose] . . . . . . . . . . . . 2-779
show running-config interface lag-group <shelf/slot> verbose . . . . . . . . . . . . . 2-780
show running-config interface muxponder-highspeed [[<shelf/slot>|<shelf/slot/
port>]|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-781
show running-config interface muxponder-highspeed [<shelf/slot>|<shelf/slot/port>]
verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-782
show running-config interface muxponder-midspeed [[<shelf/slot>|<shelf/slot/
port>]|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-783
show running-config interface muxponder-midspeed [<shelf/slot>|<shelf/slot/port>]
verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-784
show running-config interface packet-timing [<shelf/slot>|verbose] . . . . . . . . . 2-785
show running-config interface packet-timing <shelf/slot> verbose . . . . . . . . . . 2-786
show running-config interface ppp-group [<shelf/slot/group>|verbose] . . . . . . . 2-787
show running-config interface ppp-group <shelf/slot/group> verbose . . . . . . . . 2-789
show running-config interface pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remoteindex>] cem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-791
show running-config interface pseudowire [<shelf/slot>|<shelf/slot/pwe>|<remoteindex>] cem verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-792
show running-config interface pseudowire cem . . . . . . . . . . . . . . . . . . . . . . . . . 2-793
show running-config interface pseudowire cem verbose . . . . . . . . . . . . . . . . . . 2-794
show running-config interface rf-video [<remote-index>|verbose] . . . . . . . . . . . 2-795
show running-config interface rf-video <remote-index> verbose . . . . . . . . . . . . 2-796
show running-config interface shdsl [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . 2-797
show running-config interface shdsl <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-798
show running-config interface t1 [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . . 2-799
show running-config interface t1 <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . . 2-800
show running-config interface t3 [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . . 2-801
show running-config interface t3 <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . . 2-802
show running-config interface ten-gigabit-ethernet [[<shelf/slot>|<shelf/slot/
port>]|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-803
show running-config interface ten-gigabit-ethernet [<shelf/slot>|<shelf/slot/port>]
verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-804
show running-config interface vdsl [[<shelf/slot>|<shelf/slot/port>]|verbose] . . . 2-805
show running-config interface vdsl [<shelf/slot>|<shelf/slot/port>] verbose . . . . 2-806
show running-config ip igmp evc [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . 2-807
show running-config ip igmp evc WORD [<shelf/slot>|verbose] . . . . . . . . . . . . 2-808

xxiv

6TANV57CLI-35A

Contents

show running-config ip igmp evc WORD <shelf/slot> verbose . . . . . . . . . . . . . 2-809


show running-config mevc [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-810
show running-config mevc WORD [<shelf/slot> |verbose] . . . . . . . . . . . . . . . . 2-811
show running-config mevc WORD <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-812
show running-config muxponder-ethernet [<shelf/slot>|verbose] . . . . . . . . . . . 2-813
show running-config muxponder-ethernet <shelf/slot> verbose . . . . . . . . . . . . 2-814
show running-config policer [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-815
show running-config policer WORD [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . 2-816
show running-config policer WORD <shelf/slot> verbose . . . . . . . . . . . . . . . . . 2-817
show running-config power-shedding verbose . . . . . . . . . . . . . . . . . . . . . . . . . 2-819
show running-config probe responder twamp . . . . . . . . . . . . . . . . . . . . . . . . . . 2-820
show running-config probe responder twamp verbose . . . . . . . . . . . . . . . . . . . 2-821
show running-config protection-group [<shelf/slot>|verbose] . . . . . . . . . . . . . . 2-822
show running-config protection-group <shelf/slot> verbose . . . . . . . . . . . . . . . 2-823
show running-config queue interface [efm-group|ethernet|gigabit-ethernet|muxponderhighspeed|muxponder-midspeed|ten-gigabit-ethernet] . . . . . . . . . . . . . . . . . . 2-824
show running-config queue interface efm-group [<shelf/slot/group>|verbose] . 2-828
show running-config queue interface efm-group <shelf/slot/group> verbose . . 2-830
show running-config queue interface ethernet [<shelf/slot/port>|verbose] . . . . 2-833
show running-config queue interface ethernet <shelf/slot/port> verbose . . . . . 2-835
show running-config queue interface gigabit-ethernet [<shelf/slot/port>|verbose] . 2838
show running-config queue interface gigabit-ethernet <shelf/slot/port> verbose 2-840
show running-config queue interface muxponder-highspeed [<shelf/slot/port>|verbose]
2-843
show running-config queue interface muxponder-highspeed <shelf/slot/port> verbose
2-845
show running-config queue interface muxponder-midspeed [<shelf/slot/port>|verbose]
2-848
show running-config queue interface muxponder-midspeed <shelf/slot/port> verbose
2-850
show running-config queue interface ten-gigabit-ethernet [<shelf/slot/port>|verbose]
2-853
show running-config queue interface ten-gigabit-ethernet <shelf/slot/port> verbose 2855
show running-config queue verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-858
show running-config redundancy [<shelf/slot>|verbose] . . . . . . . . . . . . . . . . . . 2-863
show running-config redundancy <shelf/slot> verbose . . . . . . . . . . . . . . . . . . . 2-864
show running-config remote-device ont [<remote-index>|verbose] . . . . . . . . . . 2-865
show running-config remote-device ont <remote-index> verbose . . . . . . . . . . . 2-866
show running-config sca verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-867
show running-config security verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-868
show running-config shaper [WORD|verbose] . . . . . . . . . . . . . . . . . . . . . . . . . 2-870
show running-config shaper WORD [[<shelf/slot>|<remote-index>]|verbose] . . 2-872
show running-config shaper WORD [<shelf/slot>|<remote-index>] verbose . . . 2-873
show running-config slot verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-875
show running-config system verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-876
show running-config system-alarm [<shelf>|verbose] . . . . . . . . . . . . . . . . . . . . 2-877

6TANV57CLI-35A

xxv

Total Access/NetVanta Carrier CLI Dictionary

show running-config system-alarm <shelf> verbose . . . . . . . . . . . . . . . . . . . . . 2-878


show running-config system-management-evc verbose . . . . . . . . . . . . . . . . . . 2-879
show running-config system-timing [<shelf>|verbose] . . . . . . . . . . . . . . . . . . . . 2-880
show running-config system-timing <shelf> verbose . . . . . . . . . . . . . . . . . . . . . 2-881
show running-config temperature-sensor [<shelf/slot/sensor>|verbose] . . . . . . 2-882
show running-config temperature-sensor <shelf/slot/sensor> verbose . . . . . . . 2-883
show running-config tl1 verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-884
show running-config voice [class-of-service|dial-plan|sip-trunk|spre|user] . . . . 2-885
show running-config voice class-of-service [WORD|verbose] . . . . . . . . . . . . . . 2-886
show running-config voice class-of-service WORD verbose . . . . . . . . . . . . . . . 2-887
show running-config voice dial-plan verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-888
show running-config voice sip-trunk [<Txx>|verbose] . . . . . . . . . . . . . . . . . . . . 2-889
show running-config voice sip-trunk <Txx> verbose . . . . . . . . . . . . . . . . . . . . . 2-890
show running-config voice spre verbose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-891
show running-config voice user [NUMBER:20|verbose] . . . . . . . . . . . . . . . . . . 2-892
show running-config voice user NUMBER:20 verbose . . . . . . . . . . . . . . . . . . . 2-893
show sca [autosave-status|restore-status|save-status] . . . . . . . . . . . . . . . . . . . 2-894
show sca autosave-status realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-895
show sca restore-status realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-896
show sca save-status realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-897
show scr shelf-status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-898
show scr shelf-status realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-899
show shaper WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-900
show shaper WORD [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . 2-901
show sntp realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-903
show system [inventory|parameters] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-904
show system-timing <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-905
show system-timing <shelf> detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-906
show table [evc|evc-map|mevc|node-information|policer|shaper|system-timing] 2-908
show table evc [mac-switched|tag-switched] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-910
show table evc-map <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-911
show table evc-map evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-912
show table evc-map mevc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . 2-913
show table interfaces [adsl|efm-group|efm-link|frame-relay|gpon|rf-video|shdsl|vdsl] .
2-914
show table interfaces adsl [<shelf/slot/port>|<shelf/slot>] . . . . . . . . . . . . . . . . . 2-916
show table interfaces adsl [<shelf/slot/port>|<shelf/slot>] downstream performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-917
show table interfaces adsl [<shelf/slot/port>|<shelf/slot>] downstream performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-918
show table interfaces adsl [<shelf/slot/port>|<shelf/slot>] upstream performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-919
show table interfaces adsl [<shelf/slot/port>|<shelf/slot>] upstream performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-920
show table interfaces backplane <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . 2-921
show table interfaces backplane <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-922
show table interfaces efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . 2-923

xxvi

6TANV57CLI-35A

Contents

show table interfaces efm-group <shelf/slot/group> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-924


show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . 2-925
show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-926
show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-927
show table interfaces frame-relay [[<shelf/slot/group>|<shelf/slot>]|dlci|realtime] . . 2928
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci . . . . . . 2-929
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991> . 2930
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991> ip 2931
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991> ip
realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-932
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-933
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 15-minute congestion . . . . . . . . . . . . . . . . . . . . . . . . . . 2-934
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 15-minute congestion realtime . . . . . . . . . . . . . . . . . . . 2-935
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 15-minute realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-936
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-937
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 24-hour congestion . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-938
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 24-hour congestion realtime . . . . . . . . . . . . . . . . . . . . . 2-939
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
performance-statistics 24-hour realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-940
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci <16-991>
realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-941
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci ip . . . . . 2-942
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci ip realtime . 2943
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] dlci realtime 2-944
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-945
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 15-minute realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-946
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 15-minute signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-947
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 15-minute signaling realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-948
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-949
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 24-hour realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-950

6TANV57CLI-35A

xxvii

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 24-hour signaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-951


show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] performancestatistics 24-hour signaling realtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-952
show table interfaces frame-relay [<shelf/slot/group>|<shelf/slot>] realtime . . . 2-953
show table interfaces frame-relay dlci [ip|realtime] . . . . . . . . . . . . . . . . . . . . . . 2-954
show table interfaces frame-relay dlci ip realtime . . . . . . . . . . . . . . . . . . . . . . . 2-955
show table interfaces gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . 2-956
show table interfaces gigabit-ethernet <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-957
show table interfaces gpon [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . 2-958
show table interfaces gpon [<shelf/slot/port>|<remote-index>] performance-statistics
15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-959
show table interfaces gpon [<shelf/slot/port>|<remote-index>] performance-statistics
24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-960
show table interfaces muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . 2-961
show table interfaces muxponder-highspeed <shelf/slot/port> performance-statistics
[15-minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-962
show table interfaces muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . 2-963
show table interfaces muxponder-midspeed <shelf/slot/port> performance-statistics
[15-minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-964
show table interfaces rf-video <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . 2-965
show table interfaces shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-966
show table interfaces shdsl <shelf/slot/port> performance-statistics [15-minute|24hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-967
show table interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-968
show table interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>] performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-969
show table interfaces t3 <shelf/slot/port> performance-statistics [15-minute|24-hour]
2-970
show table interfaces ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . 2-971
show table interfaces ten-gigabit-ethernet <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-972
show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>] . . . . . . . . . . . . . . . . . 2-973
show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>] downstream performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-974
show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>] downstream performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-975
show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>] upstream performancestatistics 15-minute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-976
show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>] upstream performancestatistics 24-hour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-977
show table ip igmp evc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-978
show table ip igmp evc WORD <shelf/slot> performance-statistics [15-minute|24-hour]
2-980
show table ip igmp evc WORD performance-statistics [15-minute|24-hour] . . . 2-981
show table ip igmp evc-map WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . 2-982
show table ip igmp evc-map WORD <shelf/slot> performance-statistics [15-minute|24-

xxviii

6TANV57CLI-35A

Contents

hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-984
show table ip igmp interface adsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-985
show table ip igmp interface adsl <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-987
show table ip igmp interface backplane <shelf/slot/port> . . . . . . . . . . . . . . . . . 2-988
show table ip igmp interface backplane <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-990
show table ip igmp interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . 2-991
show table ip igmp interface gigabit-ethernet <shelf/slot/port> performance-statistics
[15-minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-993
show table ip igmp interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . 2-994
show table ip igmp interface ten-gigabit-ethernet <shelf/slot/port> performancestatistics [15-minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-996
show table ip igmp interface vdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . 2-997
show table ip igmp interface vdsl <shelf/slot/port> performance-statistics [15minute|24-hour] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-999
show table mevc <shelf/slot> [mac-switched|tag-switched] . . . . . . . . . . . . . . 2-1000
show table policer <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1001
show table queue interfaces [efm-group|ethernet|gigabit-ethernet|muxponderhighspeed|muxponder-midspeed|ten-gigabit-ethernet] . . . . . . . . . . . . . . . . . 2-1002
show table queue interfaces efm-group <shelf/slot/group> . . . . . . . . . . . . . . . 2-1003
show table queue interfaces ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . 2-1004
show table queue interfaces gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . 2-1005
show table queue interfaces muxponder-highspeed <shelf/slot/port> . . . . . . . 2-1006
show table queue interfaces muxponder-midspeed <shelf/slot/port> . . . . . . . 2-1007
show table queue interfaces ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . 2-1008
show table remote-devices [<remote-index>|inactive] . . . . . . . . . . . . . . . . . . . 2-1009
show table remote-devices inactive <shelf/slot/port> . . . . . . . . . . . . . . . . . . . 2-1010
show table shaper [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . 2-1011
show table sip registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1012
show table sip registration <shelf/slot> [<Txx>|realtime] . . . . . . . . . . . . . . . . . 2-1013
show table sip registration <shelf/slot> <Txx> [WORD|realtime] . . . . . . . . . . . 2-1014
show table sip registration <shelf/slot> <Txx> WORD realtime . . . . . . . . . . . . 2-1015
show table system-timing <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1016
show temperature-sensor <shelf/slot/sensor> . . . . . . . . . . . . . . . . . . . . . . . . . 2-1017
show topology interfaces erps <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . . . 2-1018
show topology interfaces erps <shelf/slot/ring> detail . . . . . . . . . . . . . . . . . . . 2-1019
show topology tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1020
show topology tree detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1021
show topology tree detail <1-64> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1022
show users [login-stats|realtime] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1023
show users login-stats local . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1024
show version [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1025
show vlan <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1027
telnet A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1028
telnet A.B.C.D port <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1029
terminal length <0,2-480> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1030
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> 2-

6TANV57CLI-35A

xxix

Total Access/NetVanta Carrier CLI Dictionary

1031
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191>
sorted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1032
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> ttl
<1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1034
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> ttl
<1-255> fdb-only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1036
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> ttl
<1-255> fdb-only sorted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1037
traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD WORD <1-8191> ttl
<1-255> sorted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1039
write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1040

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1041
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1042
thresholds heap free-memory <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1043

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1044
connect men-port muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . . .
connect men-port muxponder-lag-group <shelf/slot/group> . . . . . . . . . . . . . .
connect men-port muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mac-switched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
preserve-ce-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1045
2-1046
2-1047
2-1048
2-1049
2-1050
2-1051
2-1052

ADSL Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-1053


alarm enable link-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cabinet-mode [110|130|250] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dmt-options hamband-notch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dmt-options snr-margin downstream maximum <0-31> . . . . . . . . . . . . . . . . .
dmt-options snr-margin downstream minimum <0-31> . . . . . . . . . . . . . . . . . .
dmt-options snr-margin downstream target <0-31> . . . . . . . . . . . . . . . . . . . . .
dmt-options snr-margin upstream maximum <0-31> . . . . . . . . . . . . . . . . . . . .
dmt-options snr-margin upstream minimum <0-31> . . . . . . . . . . . . . . . . . . . .
dmt-options snr-margin upstream target <0-31> . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
latency-path delay downstream <0> <1-63> . . . . . . . . . . . . . . . . . . . . . . . . . .
latency-path delay upstream <0> <1-63> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
latency-path inp downstream <0> <0,0.5,1-16> . . . . . . . . . . . . . . . . . . . . . . .
latency-path inp upstream <0> <0,0.5,1-16> . . . . . . . . . . . . . . . . . . . . . . . . . .
latency-path payload-rate downstream maximum <0> <32-32000> . . . . . . . .
latency-path payload-rate downstream minimum <0> <32-32000> . . . . . . . .
latency-path payload-rate upstream maximum <0> <32-3776> . . . . . . . . . . .
latency-path payload-rate upstream minimum <0> <32-3776> . . . . . . . . . . . .
latency-path type <0> [fast|interleave] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
rate-adaption [fixed|startup] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxx

2-1054
2-1055
2-1056
2-1057
2-1058
2-1059
2-1060
2-1061
2-1062
2-1063
2-1064
2-1065
2-1067
2-1069
2-1071
2-1073
2-1075
2-1077
2-1078
2-1079
2-1080

6TANV57CLI-35A

Contents

service-mode [adsl1-multimode|adsl2|adsl2+|adsl2+m|adsl2-multimode|g-dmt|g-lite|glite2|readsl|t1-413] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1081


shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1083
thresholds es downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-1084
thresholds es upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1085
thresholds lof downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-1086
thresholds lof upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1087
thresholds lol upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1088
thresholds los downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-1089
thresholds los upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1090

Application Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . 2-1091


auto-in-service <shelf/slot> enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1096
auto-in-service <shelf/slot> timeout <1-9999> . . . . . . . . . . . . . . . . . . . . . . . . . 2-1097
copy configuration interface adsl source <shelf/slot/port> destination <port>|LIST 21098
copy configuration interface e1 source <shelf/slot/port> destination <port>|LIST . . 21099
copy configuration interface fxs source <shelf/slot/port> destination <port>|LIST . 21100
copy configuration interface shdsl source <shelf/slot/port> destination <port>|LIST 21101
copy configuration interface t1 source [<shelf/slot/port>|<shelf/slot/port:chan>]
destination <port>|LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1102
copy configuration interface t3 source <shelf/slot/port> destination <port>|LIST . . 21103
copy configuration interface vdsl source <shelf/slot/port> destination <port>|LIST . 21104
copy configuration module source <shelf/slot> destination <shelf/slot> . . . . . 2-1105
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1106
ez-efm <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1107
security account-expiration <20-365> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1108
security password-expiration <20-365> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1109
show test interface adsl <shelf/slot/port> [delt|selt] . . . . . . . . . . . . . . . . . . . . . 2-1110
show test interface adsl <shelf/slot/port> delt downstream [hlin|hlins|hlog|qln|snr] . 21111
show test interface adsl <shelf/slot/port> delt upstream [hlin|hlins|hlog|qln|snr] . . . 21112
show test interface adsl <shelf/slot/port> selt [fdr|icn] . . . . . . . . . . . . . . . . . . . 2-1113
show test interface e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1114
show test interface hdsl2 <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . 2-1115
show test interface hdsl2 <shelf/slot/port> tscan htur . . . . . . . . . . . . . . . . . . . 2-1116
show test interface hdsl4 <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . 2-1117
show test interface hdsl4 <shelf/slot/port> tscan htur . . . . . . . . . . . . . . . . . . . 2-1118
show test interface shdsl <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . 2-1119
show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . 2-1120
show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan . . . . . . . 2-1121
show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre1 . . . 2-1122
show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre2 . . . 2-1123

6TANV57CLI-35A

xxxi

Total Access/NetVanta Carrier CLI Dictionary

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre3 . . . 2-1124


show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan htuc . . . 2-1125
show test interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1126
show test interface vdsl <shelf/slot/port> [delt|selt] . . . . . . . . . . . . . . . . . . . . . 2-1127
show test interface vdsl <shelf/slot/port> delt downstream [hlin|hlins|hlog|linestatus|qln|snr] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1128
show test interface vdsl <shelf/slot/port> delt upstream [hlin|hlins|hlog|linestatus|qln|snr] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1129
show test interface vdsl <shelf/slot/port> selt [fdr|icn] . . . . . . . . . . . . . . . . . . . 2-1130
test alarm-relays <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1131
test interface adsl <shelf/slot/port> [delt|selt] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1132
test interface adsl <shelf/slot/port> delt filename WORD . . . . . . . . . . . . . . . . 2-1133
test interface adsl <shelf/slot/port> selt filename WORD . . . . . . . . . . . . . . . . 2-1134
test interface e1 <shelf/slot/port> [clear|insert-error] . . . . . . . . . . . . . . . . . . . . 2-1135
test interface e1 <shelf/slot/port> local loopback [line|payload] . . . . . . . . . . . . 2-1136
test interface e1 <shelf/slot/port> local loopback line timeout <0-9999> . . . . . 2-1137
test interface e1 <shelf/slot/port> local loopback payload timeout <0-9999> . 2-1138
test interface e1 <shelf/slot/port> remote pattern [1in8|all0s|all1s|qrss] . . . . . 2-1139
test interface e1 <shelf/slot/port> remote pattern 1in8 loopback none . . . . . . 2-1140
test interface e1 <shelf/slot/port> remote pattern 1in8 loopback none timeout <0-9999>
2-1141
test interface e1 <shelf/slot/port> remote pattern all0s loopback none . . . . . . 2-1142
test interface e1 <shelf/slot/port> remote pattern all0s loopback none timeout <09999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1143
test interface e1 <shelf/slot/port> remote pattern all1s loopback none . . . . . . 2-1144
test interface e1 <shelf/slot/port> remote pattern all1s loopback none timeout <09999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1145
test interface e1 <shelf/slot/port> remote pattern qrss loopback none . . . . . . 2-1146
test interface e1 <shelf/slot/port> remote pattern qrss loopback none timeout <0-9999>
2-1147
test interface hdsl2 <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1148
test interface hdsl2 <shelf/slot/port> tscan htur . . . . . . . . . . . . . . . . . . . . . . . . 2-1149
test interface hdsl4 <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1150
test interface hdsl4 <shelf/slot/port> tscan htur . . . . . . . . . . . . . . . . . . . . . . . . 2-1151
test interface shdsl <shelf/slot/port> psd <3-89> <3-4> . . . . . . . . . . . . . . . . . . 2-1152
test interface shdsl <shelf/slot/port> tscan . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1153
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] clear . . . . . . . . . . . . 2-1154
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] insert-error . . . . . . . 2-1155
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local loopback line . 2-1156
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local loopback line timeout <09999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1157
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local loopback payload . . 21158
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local loopback payload
timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1159
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 2-1160
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
csu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1161

xxxii

6TANV57CLI-35A

Contents

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback


csu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1162
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
fdl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1163
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
fdl timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1164
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
feac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1165
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
feac timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1166
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1167
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
niu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1168
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1169
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern 1in8 loopback
none timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1170
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s 2-1171
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
csu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1172
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
csu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1173
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
fdl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1174
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
fdl timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1175
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
feac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1176
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
feac timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1177
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1178
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
niu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1179
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1180
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all0s loopback
none timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1181
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s 2-1182
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
csu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1183
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
csu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1184
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
fdl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1185
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
fdl timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1186
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
feac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1187

6TANV57CLI-35A

xxxiii

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback


feac timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1188
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1189
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
niu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1190
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1191
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern all1s loopback
none timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1192
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss 2-1193
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
csu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1194
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
csu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1195
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
fdl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1196
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
fdl timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1197
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
feac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1198
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
feac timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1199
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1200
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
niu timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1201
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1202
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] remote pattern qrss loopback
none timeout <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1203
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan . . . . . . . . . . . . 2-1204
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre1 . . . . . . . 2-1205
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre2 . . . . . . . 2-1206
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan hre3 . . . . . . . 2-1207
test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan htuc . . . . . . . . 2-1208
test interface t3 <shelf/slot/port> [clear|insert-error] . . . . . . . . . . . . . . . . . . . . 2-1209
test interface t3 <shelf/slot/port> local loopback line . . . . . . . . . . . . . . . . . . . . 2-1210
test interface t3 <shelf/slot/port> local loopback line timeout <0-9999> . . . . . 2-1211
test interface t3 <shelf/slot/port> remote pattern [p215|p220|p223] . . . . . . . . 2-1212
test interface t3 <shelf/slot/port> remote pattern p215 loopback [line|none] . . 2-1213
test interface t3 <shelf/slot/port> remote pattern p215 loopback line timeout <0-9999>
2-1214
test interface t3 <shelf/slot/port> remote pattern p215 loopback none timeout <0-9999>
2-1215
test interface t3 <shelf/slot/port> remote pattern p220 loopback [line|none] . . 2-1216
test interface t3 <shelf/slot/port> remote pattern p220 loopback line timeout <0-9999>
2-1217
test interface t3 <shelf/slot/port> remote pattern p220 loopback none timeout <0-9999>

xxxiv

6TANV57CLI-35A

Contents

2-1218
test interface t3 <shelf/slot/port> remote pattern p223 loopback [line|none] . . 2-1219
test interface t3 <shelf/slot/port> remote pattern p223 loopback line timeout <0-9999>
2-1220
test interface t3 <shelf/slot/port> remote pattern p223 loopback none timeout <0-9999>
2-1221
test interface vdsl <shelf/slot/port> [delt|selt] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1222
test interface vdsl <shelf/slot/port> delt filename WORD . . . . . . . . . . . . . . . . 2-1223
test interface vdsl <shelf/slot/port> selt filename WORD . . . . . . . . . . . . . . . . . 2-1224
validate radius-server host A.B.C.D username WORD password . . . . . . . . . . 2-1225
validate tacacs-server host A.B.C.D username WORD password . . . . . . . . . 2-1227

ATM Group Interface Configuration Command Set . . . . . . . . . . . . . . . 2-1229


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1230
link [<slot/port> |<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1231
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1232

ATM Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . . 2-1233


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1234
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1235
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1236

Auto Upgrade Configuration Command Set . . . . . . . . . . . . . . . . . . . . . 2-1237


alarm enable [complete|failed|software-version-error|started|unknown-module] . . 21238
alarm enable file [bad|changed] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1239
alarm level software-version-error [alert|critical|major|minor] . . . . . . . . . . . . . 2-1240
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1241
mode [auto|disabled|manual] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1242
refresh-interval <0-744> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1243
release WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1244
retries <0-10> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1245
scr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1246

Counter Profile Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-1247


color [green|red|yellow] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
pbit <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
vlan [<0-4094>|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1248
2-1249
2-1250
2-1251

Dynamic Counters Configuration Command Set . . . . . . . . . . . . . . . . . 2-1252


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
set counter-profile <shelf/slot/index> [exclude|include] . . . . . . . . . . . . . . . . . .
set interface backplane <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . . . . . . . . . .
set interface backplane <shelf/slot/port> queue <0-n> [congestiondrop|dequeue|enqueue] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
set interface efm-group <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . . . . . . . . . .
set interface efm-group <shelf/slot/port> queue <0-n> [congestiondrop|dequeue|enqueue] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
set interface ethernet <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . . . . . . . . . . . .
set interface ethernet <shelf/slot/port> queue <0-n> [congestion-

6TANV57CLI-35A

2-1253
2-1254
2-1255
2-1256
2-1257
2-1258
2-1260

xxxv

Total Access/NetVanta Carrier CLI Dictionary

drop|dequeue|enqueue] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1261
set interface gigabit-ethernet <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . . . . . . 2-1263
set interface gigabit-ethernet <shelf/slot/port> queue <0-n> [congestiondrop|dequeue|enqueue] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1264
set interface lag-group <shelf/slot/group> [rx|tx] . . . . . . . . . . . . . . . . . . . . . . . 2-1266
set interface muxponder-highspeed <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . 2-1267
set interface muxponder-midspeed <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . 2-1268
set interface processor-ethernet [rx|tx] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1269
set interface processor-ethernet queue <0-n> [congestion-drop|dequeue|enqueue] 21270
set interface ten-gigabit-ethernet <shelf/slot/port> [rx|tx] . . . . . . . . . . . . . . . . . 2-1272
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1273

E1 Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . 2-1274


alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service timeout <1-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock source [internal|line] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
coding [ami|hdb3] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
framing [cas|cas-crc|ccs|ccs-crc|unframed] . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-alarm [ebit|rai] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-p 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-p 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
timeout loopback <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1275
2-1276
2-1277
2-1278
2-1279
2-1280
2-1281
2-1282
2-1283
2-1284
2-1286
2-1287
2-1288
2-1289
2-1290
2-1291
2-1292
2-1293
2-1294
2-1295
2-1296
2-1297
2-1298

EFM Group Interface Configuration Command Set . . . . . . . . . . . . . . . 2-1299


active-links-minimum <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alias WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm mep <1-8191> WORD WORD [down|up] . . . . . . . . . . . . . . . . . .
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link [<slot/port>|<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xxxvi

2-1301
2-1302
2-1303
2-1304
2-1305
2-1306
2-1307
2-1308
2-1309

6TANV57CLI-35A

Contents

loopback [detection|remote] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1310


loopback timeout <0-60> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1311
rate-control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1312
rate-control upstream <0-250000> downstream <0-250000> . . . . . . . . . . . . . 2-1313
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1314
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1315
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1316
subtended-host ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1317
subtended-host ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . 2-1318
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1319
subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . . 2-1320
subtended-host mode [disabled|listener|sender] . . . . . . . . . . . . . . . . . . . . . . . 2-1321
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . . 2-1322
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . . 2-1323
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . . 2-1324
subtended-host snmp-server ez-provisioning host A.B.C.D traps version [1|2c] . . . 21325
subtended-host snmp-server location WORD . . . . . . . . . . . . . . . . . . . . . . . . . 2-1326
subtended-host s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1327
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1328
thresholds bad-fragments 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . 2-1329
thresholds bad-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . 2-1330
thresholds lost-ends 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1331
thresholds lost-ends 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1332
thresholds lost-fragments 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . 2-1333
thresholds lost-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-1334
thresholds lost-starts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . 2-1335
thresholds lost-starts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . 2-1336
thresholds xcv [1e-5|1e-6|1e-7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1337
xcv-link-removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1338

EFM Link Interface Configuration Command Set . . . . . . . . . . . . . . . . . 2-1339


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds coding-errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . .
thresholds coding-errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . .
thresholds discarded-fragments 15-minute <0-4294967295> . . . . . . . . . . . . .
thresholds discarded-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . .
thresholds errored-fragments 15-minute <0-4294967295> . . . . . . . . . . . . . . .
thresholds errored-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . . . .
thresholds fcs-errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds fcs-errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . .
thresholds large-fragments 15-minute <0-4294967295> . . . . . . . . . . . . . . . . .
thresholds large-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . .
thresholds small-fragments 15-minute <0-4294967295> . . . . . . . . . . . . . . . .
thresholds small-fragments 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . .

2-1340
2-1341
2-1342
2-1343
2-1344
2-1345
2-1346
2-1347
2-1348
2-1349
2-1350
2-1351
2-1352
2-1353

EFM Port Interface Configuration Command Set . . . . . . . . . . . . . . . . . 2-1354

6TANV57CLI-35A

xxxvii

Total Access/NetVanta Carrier CLI Dictionary

exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mac limit <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth control-direction [both|in] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth eap-req <1-10> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth port-control [auto|force-authorized|force-unauthorized] . . . . . . . . . .
port-auth re-authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth timeout eap-response <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth timeout quiet-period <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
port-auth timeout re-authperiod <1-4294967295> . . . . . . . . . . . . . . . . . . . . . .
port-auth timeout server <1-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1355
2-1356
2-1357
2-1358
2-1359
2-1360
2-1361
2-1362
2-1363
2-1364
2-1365
2-1366

ERPS Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-1367


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
east interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . .
east interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
force-switch [east|west] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
guard-timer <10-2000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
rpl-owner [east|west] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
wait-to-restore <5-720> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
west interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . .
west interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .

2-1368
2-1369
2-1370
2-1371
2-1372
2-1373
2-1374
2-1375
2-1377
2-1378
2-1379

Ethernet Interface Configuration Command Set . . . . . . . . . . . . . . . . . . 2-1380


crossover [auto|mdi|mdi-x] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm mep <1-8191> WORD WORD [down|up] . . . . . . . . . . . . . . . . . .
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
full-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
half-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address [A.B.C.D|dhcp] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link-state-awareness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mac aging-time <0-3600> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mac limit <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
speed [10|100|auto] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip address A.B.C.D P.Q.R.S . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . .

xxxviii

2-1382
2-1383
2-1384
2-1385
2-1386
2-1387
2-1388
2-1389
2-1390
2-1391
2-1392
2-1393
2-1394
2-1395
2-1396
2-1397
2-1398
2-1399
2-1400
2-1401
2-1402

6TANV57CLI-35A

Contents

subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . . 2-1403


subtended-host mode [disabled|listener|sender] . . . . . . . . . . . . . . . . . . . . . . . 2-1404
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . . 2-1405
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . . 2-1406
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . . 2-1407
subtended-host snmp-server ez-provisioning host A.B.C.D traps version [1|2c] . . . 21408
subtended-host snmp-server location WORD . . . . . . . . . . . . . . . . . . . . . . . . . 2-1409
subtended-host s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1410
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1411
thresholds broadcasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-1412
thresholds broadcasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1413
thresholds collisions 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1414
thresholds collisions 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1415
thresholds discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1416
thresholds discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1417
thresholds errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1418
thresholds errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1419
thresholds giants 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1420
thresholds giants 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1421
thresholds invalid-vlan 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-1422
thresholds invalid-vlan 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1423
thresholds link-state-awareness bandwidth-minimum <0-2147483647> . . . . . 2-1424
thresholds link-state-awareness links-minimum <0-n> . . . . . . . . . . . . . . . . . . 2-1425
thresholds multicasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . 2-1426
thresholds multicasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . 2-1427
thresholds peak-mac-entries 15-minute <0-n> . . . . . . . . . . . . . . . . . . . . . . . . 2-1428
thresholds peak-mac-entries 24-hour <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1429
thresholds runts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . 2-1430
thresholds runts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1431

Ethernet OAM Association Configuration Command Set . . . . . . . . . . 2-1432


ccm interval [100-milliseconds|10-minutes|10-seconds|1-minute|1-second] . .
ccm-enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
component <1-n> vlan [<1-4094>|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-database [auto-discovery|clear|configured-only|lock] . . . . . . . . . . . . . . .
mep-database auto-discovery auto-learn . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-database clear <1-8191> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-database lock <1-8191> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-validation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-validation start-delay <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-mep <1-8191> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1433
2-1434
2-1435
2-1436
2-1437
2-1438
2-1439
2-1440
2-1441
2-1442
2-1443
2-1444

Ethernet OAM Component Configuration Command Set. . . . . . . . . . . 2-1445


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1446
mip-allowed [any|any-with-mep|defer|none] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1447

6TANV57CLI-35A

xxxix

Total Access/NetVanta Carrier CLI Dictionary

mp-sender-id [chassis-id|defer|management-address|none] . . . . . . . . . . . . . . 2-1448


mp-sender-id chassis-id management-address . . . . . . . . . . . . . . . . . . . . . . . . 2-1449

Ethernet OAM Default Domain Component Configuration Command Set . 21450


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
level [<0-7>|defer] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mip-allowed [any|any-with-mep|defer|none] . . . . . . . . . . . . . . . . . . . . . . . . . .
mip-sender-id [chassis-id|defer|management-address|none] . . . . . . . . . . . . .
mip-sender-id chassis-id management-address . . . . . . . . . . . . . . . . . . . . . . .

2-1451
2-1452
2-1453
2-1454
2-1455

Ethernet OAM Default Domain Configuration Command Set . . . . . . . 2-1456


component <1-n> vlan <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mip-allowed-default [any|any-with-mep|none] . . . . . . . . . . . . . . . . . . . . . . . . .
mip-level-default <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mip-sender-id-default [chassis-id|management-address|none] . . . . . . . . . . . .
mip-sender-id-default chassis-id management-address . . . . . . . . . . . . . . . . .

2-1457
2-1458
2-1459
2-1460
2-1461
2-1462

Ethernet OAM Domain Configuration Command Set . . . . . . . . . . . . . . 2-1463


association char-string WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
association char-string WORD index <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . .
ccm-enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mep-shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mip-allowed [any|any-with-mep|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mp-sender-id [chassis-id|management-address|none] . . . . . . . . . . . . . . . . . .
mp-sender-id chassis-id management-address . . . . . . . . . . . . . . . . . . . . . . . .

2-1464
2-1465
2-1466
2-1467
2-1468
2-1469
2-1470
2-1471

Ethernet OAM MEP Configuration Command Set . . . . . . . . . . . . . . . . . 2-1472


alarm-priority-level [errorccm|macstatus|none|rdi-ccm|remoteccm|xconccm] .
alarm-timers <2500-10000> <2500-10000> . . . . . . . . . . . . . . . . . . . . . . . . . .
ccm-enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link-state-awareness <1-8191> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link-state-awareness <1-8191> no-ccm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1473
2-1474
2-1475
2-1476
2-1477
2-1478
2-1479
2-1480

EVC Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1481


connect men-port [default-ethernet|legacy-ppp-group] . . . . . . . . . . . . . . . . . .
connect men-port efm-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . .
connect men-port ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . .
connect men-port gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .
connect men-port lag-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . .
connect men-port ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . .
double-tag-switched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mac-switched . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
preserve-ce-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xl

2-1482
2-1483
2-1484
2-1485
2-1486
2-1487
2-1488
2-1489
2-1490
2-1491

6TANV57CLI-35A

Contents

shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1492
s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1493
subscriber igmp priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1494

EVC Map Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . 2-1495


connect discard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1497
connect evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1498
connect ip-host WORD [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . 2-1499
connect mevc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1500
connect uni atm <shelf/slot/port.sub> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1501
connect uni efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1502
connect uni efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1503
connect uni ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1504
connect uni frame-relay <shelf/slot/group> dlci <16-991> . . . . . . . . . . . . . . . . 2-1505
connect uni gigabit-ethernet [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . 2-1506
connect uni muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . 2-1507
connect uni muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . 2-1508
connect uni ppp-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1509
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1510
encapsulation [auto|ethernet] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1511
encapsulation pppoa [llc|vc-mux] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1512
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1513
match [broadcast|l2cp|multicast|unicast|untagged] . . . . . . . . . . . . . . . . . . . . . 2-1514
match ce-vlan-id <0-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1515
match ce-vlan-pri <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1516
match dscp <0-63> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1517
match ethertype HHHH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1518
match source mac-address xx:xx:xx:xx:xx:xx . . . . . . . . . . . . . . . . . . . . . . . . . 2-1519
match source mac-address xx:xx:xx:xx:xx:xx xx:xx:xx:xx:xx:xx . . . . . . . . . . . 2-1520
men-c-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1521
men-c-tag-pri [<0-7>|inherit] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1522
men-pri [<0-7>|inherit] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1523
men-queue [<0-7>|inherit] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1525
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1526
subscriber access dhcp mode [authenticate|block|transparent] . . . . . . . . . . . 2-1527
subscriber access dhcp option-82 [loop-characteristics|remote-id] . . . . . . . . . 2-1528
subscriber access dhcp option-82 circuit-id WORD . . . . . . . . . . . . . . . . . . . . 2-1529
subscriber access mac-filter destination upstream [allow-all|gateway-only] . . 2-1530
subscriber access pppoe intermediate-agent [loop-characteristics|remote-id] 2-1531
subscriber access pppoe intermediate-agent circuit-id WORD . . . . . . . . . . . . 2-1532
subscriber access pppoe mode [authenticate|block|transparent] . . . . . . . . . . 2-1533
subscriber access static-ip A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1534
subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx . . . . . . . . . . . . . . . . . . . 2-1535
subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx A.B.C.D . . . . . . . . . . . . 2-1536
subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx A.B.C.D xx:xx:xx:xx:xx:xx . . 21537
subscriber arp mode [block|proxy|transparent] . . . . . . . . . . . . . . . . . . . . . . . . 2-1538
subscriber igmp immediate-leave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1539

6TANV57CLI-35A

xli

Total Access/NetVanta Carrier CLI Dictionary

subscriber igmp max-multicast bandwidth <0-n> . . . . . . . . . . . . . . . . . . . . . .


subscriber igmp max-multicast groups <0-n> . . . . . . . . . . . . . . . . . . . . . . . . .
subscriber igmp mode [block|processing-enabled|transparent] . . . . . . . . . . .
subscriber igmp proxy router ip address A.B.C.D . . . . . . . . . . . . . . . . . . . . . .

2-1540
2-1541
2-1542
2-1543

Event Log Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . 2-1544


alarm enable system-log [failure|full] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mode [capacity|scheduled] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
prefix WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
retries <0-2> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
schedule <HH:MM> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
schedule <HH:MM> every <1-90> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
suffix WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
update-only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1545
2-1546
2-1547
2-1548
2-1549
2-1550
2-1551
2-1552
2-1553
2-1554

EZ-EFM Application Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1555


create WORD link [<slot/port>|<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . . . . 2-1556
create WORD link [<slot/port>|<slot/port:chan>] upstream <1-250000> downstream
<1-250000> active-links-minimum <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1557
delete WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1559
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1560
modify WORD link [<slot/port>|<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . . . . 2-1561
modify WORD link [<slot/port>|<slot/port:chan>] upstream <1-250000> downstream
<1-250000> active-links-minimum <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1562
modify WORD no-link [<slot/port>|<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . 2-1564
modify WORD no-link [<slot/port>|<slot/port:chan>] upstream <0-250000>
downstream <0-250000> active-links-minimum <1-n> . . . . . . . . . . . . . . . . . 2-1565
modify WORD upstream <1-250000> downstream <1-250000> active-links-minimum
<1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1567

Fan Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1569


alarm enable [multiple-fan|single-fan] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1570
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1571
speed [auto|max] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1572

Frame Relay Group Interface Configuration Command Set. . . . . . . . . 2-1573


connect t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . . . . . . . . .
connect t1 [<shelf/slot/port>|<shelf/slot/port:chan>] timeslots <1-24> . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lmi-type [ansi|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1574
2-1575
2-1576
2-1577
2-1578

Frame Relay PVC Interface Configuration Command Set . . . . . . . . . . 2-1579


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
inverse-arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mtu <262-1600> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip address A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xlii

2-1580
2-1581
2-1582
2-1583
2-1584
2-1585

6TANV57CLI-35A

Contents

peer default ip default-gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1586


peer default ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1587
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1588

FXS Interface Configuration Command Set. . . . . . . . . . . . . . . . . . . . . . 2-1589


alarm enable [line-showering|trunk-conditioning] . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
impedance [600r|900c|auto|z1|z2|z3|z4|z5|z6|z7|z8] . . . . . . . . . . . . . . . . . . .
ring-voltage <50,60,70,80> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
signaling [ground-start|loop-start|tr08-sp|tr08-uvg] . . . . . . . . . . . . . . . . . . . . .
test [battery|line|reverse-battery|ringing|tip-open] . . . . . . . . . . . . . . . . . . . . . .
test tone [far|near] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1590
2-1591
2-1592
2-1593
2-1594
2-1595
2-1597
2-1598
2-1599

Gigabit-Ethernet Interface Configuration Command Set . . . . . . . . . . . 2-1600


alarm enable [downstream-fault|heartbeat-loss|lacp-timeout|link-down-enterprise|linkdown-rfc2863|port-mode|upstream-node] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1602
alarm enable pluggable [fault|missing|speed-mismatch|temperature-high|unknown] .
2-1603
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1604
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1605
downlink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1606
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1607
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1608
ethernet cfm mep <1-8191> WORD WORD [down|up] . . . . . . . . . . . . . . . . . . 2-1609
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1610
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1611
full-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1612
half-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1613
lacp grammar standby-aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1614
lacp mode [active|passive] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1615
link-state-awareness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1616
mac aging-time <0-3600> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1617
mac limit [<1-n>|disabled] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1618
mtu <1500-10000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1619
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1620
speed [10|100|1000|2500|auto] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1622
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1624
subtended-host ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1625
subtended-host ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . 2-1626
subtended-host ip address dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1627
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1628
subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . . 2-1629
subtended-host mode [disabled|listener|sender] . . . . . . . . . . . . . . . . . . . . . . . 2-1630
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . . 2-1631
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . . 2-1632
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . . 2-1633

6TANV57CLI-35A

xliii

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server ez-provisioning host A.B.C.D traps version [1|2c] . . . 21634


subtended-host snmp-server location WORD . . . . . . . . . . . . . . . . . . . . . . . . . 2-1635
subtended-host s-tag [<1-4094>|inherit] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1636
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1637
thresholds broadcasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-1638
thresholds broadcasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1639
thresholds discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1640
thresholds discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1641
thresholds errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1642
thresholds errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1643
thresholds giants 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-1644
thresholds giants 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1645
thresholds invalid-vlan 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-1646
thresholds invalid-vlan 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-1647
thresholds link-state-awareness bandwidth-minimum <0-2147483647> . . . . . 2-1648
thresholds link-state-awareness links-minimum <0-n> . . . . . . . . . . . . . . . . . . 2-1649
thresholds multicasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . 2-1650
thresholds multicasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . 2-1651
thresholds peak-mac-entries 15-minute <0-n> . . . . . . . . . . . . . . . . . . . . . . . . 2-1652
thresholds peak-mac-entries 24-hour <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1653
thresholds runts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . 2-1654
thresholds runts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1655

Global Configuration Command Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1656


aaa accounting commands <1,15> default none . . . . . . . . . . . . . . . . . . . . . . .
aaa accounting commands <1,15> default stop-only group tacacs+ . . . . . . .
aaa accounting exec default none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa accounting exec default start-stop group tacacs+ . . . . . . . . . . . . . . . . . .
aaa accounting exec default stop-only group tacacs+ . . . . . . . . . . . . . . . . . . .
aaa accounting update newinfo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa accounting update periodic <1-1440> . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa authentication eep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa authentication login default group [radius|tacacs+] . . . . . . . . . . . . . . . . . .
aaa authentication login default group radius local . . . . . . . . . . . . . . . . . . . . .
aaa authentication login default group tacacs+ group radius . . . . . . . . . . . . .
aaa authentication login default group tacacs+ group radius local . . . . . . . . .
aaa authentication login default group tacacs+ local . . . . . . . . . . . . . . . . . . . .
aaa authentication login default local . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa authorization commands <1,15> default group tacacs+ . . . . . . . . . . . . . .
aaa authorization commands <1,15> default none . . . . . . . . . . . . . . . . . . . . .
aaa authorization config-command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
aaa authorization exec default group tacacs+ . . . . . . . . . . . . . . . . . . . . . . . . .
aaa authorization exec default none . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
arp timeout <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
arp timeout <shelf/slot> <0-2147460> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-provisioning [controller|module] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

xliv

2-1664
2-1666
2-1668
2-1669
2-1670
2-1671
2-1672
2-1673
2-1675
2-1677
2-1678
2-1679
2-1680
2-1681
2-1682
2-1684
2-1686
2-1688
2-1689
2-1690
2-1691
2-1692
2-1693

6TANV57CLI-35A

Contents

banner login <character> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


boot system flash WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
boot system flash WORD WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock dst-auto-adjust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock dst-auto-adjust pre-2007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock set <HH:MM:SS> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock set <HH:MM:SS> <1-31> MONTH <2000-2036> . . . . . . . . . . . . . . . . . .
clock timezone WORD <-23-23> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock timezone WORD <-23-23> <0-59> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
counter-profile <shelf/slot/index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dynamic-counter <shelf/slot/index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
end . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm [default-domain|enable] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm domain char-string WORD level <0-7> . . . . . . . . . . . . . . . . . . . .
ethernet cfm domain char-string WORD level <0-7> index <1-n> . . . . . . . . . .
ethernet cfm traceroute cache hold-time <1-65535> . . . . . . . . . . . . . . . . . . . .
ethernet cfm traceroute cache hold-time <1-65535> size <1-4095> . . . . . . . .
ethernet cfm traceroute cache size <1-4095> . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet default interface efm-group [<shelf/slot/group>|WORD] . . . . . . . . . .
ethernet default interface erps <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . . .
ethernet default interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . .
ethernet default interface lag-group [<shelf/slot/group>|WORD] . . . . . . . . . . .
ethernet default interface rpr <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet default interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . .
ethernet internal-system-s-tag <2-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet s-tag-tpid HHHH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
evc-map WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
evc-map WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
event-log-export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
fan <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
fxs battery-remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
fxs battery-remove <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface adsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface atm [<shelf/slot/port>|<shelf/slot/port.sub>] . . . . . . . . . . . . . . . . . . .
interface atm-group <shelf/slot/group> legacy-atm . . . . . . . . . . . . . . . . . . . . .
interface e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface efm-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . . . . . . . . .
interface efm-link [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . . . .
interface efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface erps <shelf/slot/ring> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface frame-relay <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
interface frame-relay <shelf/slot/group> dlci <16-991> . . . . . . . . . . . . . . . . . .
interface fxs [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . .

6TANV57CLI-35A

2-1694
2-1695
2-1696
2-1697
2-1698
2-1699
2-1700
2-1701
2-1702
2-1703
2-1704
2-1705
2-1707
2-1708
2-1709
2-1711
2-1712
2-1713
2-1714
2-1715
2-1716
2-1717
2-1718
2-1719
2-1720
2-1721
2-1722
2-1723
2-1724
2-1725
2-1726
2-1728
2-1729
2-1730
2-1731
2-1732
2-1733
2-1734
2-1735
2-1736
2-1737
2-1738
2-1739
2-1740
2-1741
2-1742
2-1743

xlv

Total Access/NetVanta Carrier CLI Dictionary

interface gigabit-ethernet [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . 2-1744


interface gpon <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1745
interface hdsl2 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1746
interface hdsl4 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1747
interface ip-host WORD [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . 2-1748
interface lag-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . . . . . . . . . . 2-1749
interface muxponder-highspeed <shelf/slot/interface> ten-gigabit-ethernet . . 2-1750
interface muxponder-midspeed <shelf/slot/interface> gigabit-ethernet . . . . . . 2-1751
interface packet-timing <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1752
interface ppp-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . . . . . . . . . 2-1753
interface pseudowire [<shelf/slot/pwe>|<remote-index>] cem . . . . . . . . . . . . . 2-1754
interface rf-video <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1755
interface shdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1756
interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] . . . . . . . . . . . . . . . . . . . . 2-1757
interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1758
interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . 2-1759
interface vdsl <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1760
ip [domain-lookup|forwarding|syslog] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1761
ip access-list standard WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1762
ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1763
ip domain-name-list LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1764
ip file-server auto-upgrade filename WORD . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1765
ip file-server auto-upgrade path WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1766
ip file-server default filename WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1767
ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1768
ip file-server default path WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1769
ip file-server default protocol [file-transfer-over-tl1|ftp|sftp|tftp] . . . . . . . . . . . . 2-1770
ip file-server default username WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1771
ip file-server default username WORD password . . . . . . . . . . . . . . . . . . . . . . 2-1772
ip file-server download-cache expire <60-1440> . . . . . . . . . . . . . . . . . . . . . . . 2-1773
ip file-server event-log-export host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1774
ip file-server event-log-export path WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1775
ip file-server general-export host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1776
ip file-server general-export path WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1777
ip file-server general-export retries <0-2> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1778
ip file-server sca filename WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1779
ip file-server sca host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1780
ip file-server sys-log-export host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1781
ip igmp evc WORD <shelf/slot> mode [proxy|snooping|transparent] . . . . . . . 2-1782
ip igmp evc WORD <shelf/slot> proxy host ip address A.B.C.D . . . . . . . . . . . 2-1783
ip igmp evc WORD <shelf/slot> proxy last-member-query count <1-255> . . . 2-1784
ip igmp evc WORD <shelf/slot> proxy last-member-query interval <100-65535> . . 21785
ip name-server primary A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1786
ip name-server secondary A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1787
ip ntp server A.B.C.D prefer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1788
ip ntp server A.B.C.D prefer version <3-4> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1789

xlvi

6TANV57CLI-35A

Contents

ip ntp server A.B.C.D version <3-4> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1790


ip ntp server A.B.C.D version <3-4> prefer . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1791
ip power-shedding remote-server A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1792
ip raw-tl1 [server|tcp-dead-client] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1793
ip raw-tl1 server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1794
ip raw-tl1 server <1024-65535> ssh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1795
ip route A.B.C.D A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1796
ip rtp udp <1026-60000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1797
ip snmp agent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1798
ip sntp refresh-period <1-60> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1799
ip sntp server A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1800
ip ssh [server|tunnels] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1801
ip ssh key size <512-2048> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1802
ip ssh server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1803
ip ssh-tl1 server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1804
ip ssh-tl1 server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1805
ip ssh-tl1-secondary server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1806
ip ssh-tl1-secondary server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1807
ip telnet [dead-client|server] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1808
ip telnet mode [cli|menus] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1809
ip telnet server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1810
ip telnet server <1024-65535> ssh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1811
ip telnet-secondary mode [cli|menus] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1812
ip telnet-secondary server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1813
ip telnet-secondary server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1814
ip telnet-secondary server <1024-65535> ssh . . . . . . . . . . . . . . . . . . . . . . . . 2-1815
ip telnet-tl1 server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1816
ip telnet-tl1 server <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1817
ip telnet-tl1 server <1024-65535> ssh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1818
ip terminal-server telnet admin [security|server] . . . . . . . . . . . . . . . . . . . . . . . 2-1819
ip terminal-server telnet admin server <1024-65535> . . . . . . . . . . . . . . . . . . . 2-1820
ip terminal-server telnet admin server <1024-65535> ssh-tunnel . . . . . . . . . . 2-1821
ip terminal-server telnet network [security|server] . . . . . . . . . . . . . . . . . . . . . . 2-1822
ip terminal-server telnet network server <1024-65535> . . . . . . . . . . . . . . . . . 2-1823
ip terminal-server telnet network server <1024-65535> ssh-tunnel . . . . . . . . . 2-1824
line admin <0> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1825
line console <0> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1826
line network <0> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1827
line-timeout <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1828
mevc WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1829
mode [<shelf/slot>|<remote-index>] voice fxs-signaling . . . . . . . . . . . . . . . . . 2-1830
mode [<shelf/slot>|<remote-index>] voice mgcp . . . . . . . . . . . . . . . . . . . . . . . 2-1831
mode [<shelf/slot>|<remote-index>] voice sip . . . . . . . . . . . . . . . . . . . . . . . . . 2-1832
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> . . . . . . . . . . . . . . 2-1833
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> . . . . . . . . 2-1834
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> . . . 2-1835
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> . . 2-

6TANV57CLI-35A

xlvii

Total Access/NetVanta Carrier CLI Dictionary

1836
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7>
2-1837
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7>
<0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1838
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7>
<0-7> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1839
muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7>
<0-7> <0-7> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1840
muxponder-ethernet <shelf/slot> qos untagged <0-7> . . . . . . . . . . . . . . . . . . 2-1841
muxponder-ethernet <shelf/slot> queue time-constant wred
[125|16|2|250|32|4|500|62|8] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1842
network-name WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1843
node-number <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1844
policer WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1845
policer WORD <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1846
power-shedding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1847
probe responder twamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1848
protection-group [<shelf/group>|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1849
qos cos-map <0-n> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1850
qos cos-map <0-n> <0-7> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1851
qos cos-map <0-n> <0-7> <0-7> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1852
qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> . . . . . . . . . . . . . . . . . . . . . . . . 2-1853
qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> . . . . . . . . . . . . . . . . . . . 2-1855
qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> . . . . . . . . . . . . . . 2-1857
qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> . . . . . . . . . 2-1859
qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> . . . . 2-1861
qos untagged <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1863
queue interface efm-group [<shelf/slot/group>|WORD] <0-n> . . . . . . . . . . . . 2-1864
queue interface ethernet <shelf/slot/port> <0-n> . . . . . . . . . . . . . . . . . . . . . . . 2-1865
queue interface gigabit-ethernet <shelf/slot/port> <0-n> . . . . . . . . . . . . . . . . . 2-1866
queue interface muxponder-highspeed <shelf/slot/port> <0-n> . . . . . . . . . . . 2-1867
queue interface muxponder-midspeed <shelf/slot/port> <0-n> . . . . . . . . . . . . 2-1868
queue interface ten-gigabit-ethernet <shelf/slot/port> <0-n> . . . . . . . . . . . . . . 2-1869
queue time-constant wred [125|16|2|250|32|4|500|62|8] . . . . . . . . . . . . . . . . . 2-1870
radius-server auth-port <1024-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1871
radius-server default-privilege [admin|config|readonly|readwrite|test] . . . . . . . 2-1872
radius-server host A.B.C.D auth-port <1024-65535> key WORD . . . . . . . . . . 2-1873
radius-server host A.B.C.D auth-port <1024-65535> key WORD timeout <1-30> . 21874
radius-server host A.B.C.D auth-port <1024-65535> timeout <1-30> . . . . . . . 2-1875
radius-server host A.B.C.D auth-port <1024-65535> timeout <1-30> key WORD . 21876
radius-server host A.B.C.D key WORD auth-port <1024-65535> . . . . . . . . . . 2-1877
radius-server host A.B.C.D key WORD auth-port <1024-65535> timeout <1-30> . 21878
radius-server host A.B.C.D key WORD timeout <1-30> . . . . . . . . . . . . . . . . . 2-1879
radius-server host A.B.C.D key WORD timeout <1-30> auth-port <1024-65535> . 2-

xlviii

6TANV57CLI-35A

Contents

1880
radius-server host A.B.C.D name WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1881
radius-server host A.B.C.D retransmit <1-255> . . . . . . . . . . . . . . . . . . . . . . . . 2-1882
radius-server host A.B.C.D sequence-number <0-4> . . . . . . . . . . . . . . . . . . . 2-1883
radius-server host A.B.C.D timeout <1-30> auth-port <1024-65535> . . . . . . . 2-1884
radius-server host A.B.C.D timeout <1-30> auth-port <1024-65535> key WORD . 21885
radius-server host A.B.C.D timeout <1-30> key WORD . . . . . . . . . . . . . . . . . 2-1886
radius-server host A.B.C.D timeout <1-30> key WORD auth-port <1024-65535> . 21887
radius-server key WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1888
radius-server retransmit <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1889
radius-server timeout <1-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1890
radius-server tl1-login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1891
redundancy <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1892
remote-device ont <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1893
sca . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1894
scr mode [auto|manual|scheduled] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1895
scr schedule <HH:MM> <1-31> MONTH <2000-2099> . . . . . . . . . . . . . . . . . 2-1896
security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1897
shaper WORD [<shelf/slot>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . . . 2-1898
shdsl mode [ltu|ntu] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1899
shdsl timeout training <60-240> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1900
slot alarm enable shutdown maintenance <shelf/slot> . . . . . . . . . . . . . . . . . . 2-1901
slot shutdown <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1902
slot shutdown maintenance <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1903
slot shutdown unassigned <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1904
slot-alarm <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1905
snmp-server [chassis-id-tid-sync|config-change|non-vol-card-status] . . . . . . . 2-1906
snmp-server alarm enable authenticate-failure . . . . . . . . . . . . . . . . . . . . . . . . 2-1907
snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1908
snmp-server community read-only WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1909
snmp-server community read-write WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1910
snmp-server config-change ignore source A.B.C.D . . . . . . . . . . . . . . . . . . . . 2-1911
snmp-server config-change ignore type controller . . . . . . . . . . . . . . . . . . . . . . 2-1912
snmp-server contact WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1913
snmp-server enable traps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1914
snmp-server ez-provisioning host A.B.C.D traps version [1|2c] . . . . . . . . . . . 2-1915
snmp-server host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1916
snmp-server host A.B.C.D traps [config-change|confirmation] . . . . . . . . . . . . 2-1917
snmp-server host A.B.C.D traps config-change enable . . . . . . . . . . . . . . . . . . 2-1918
snmp-server host A.B.C.D traps mode [invalid|under-creation|valid] . . . . . . . 2-1919
snmp-server host A.B.C.D traps retry-limit <0-10> . . . . . . . . . . . . . . . . . . . . . 2-1920
snmp-server host A.B.C.D traps timeout <1-10> . . . . . . . . . . . . . . . . . . . . . . . 2-1921
snmp-server host A.B.C.D traps version [1|2c] . . . . . . . . . . . . . . . . . . . . . . . . 2-1922
snmp-server ifindex-mode [fixed|sequential] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1923
snmp-server location WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1924

6TANV57CLI-35A

xlix

Total Access/NetVanta Carrier CLI Dictionary

srm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
system-alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
system-alarm <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
system-management-evc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
system-timing <shelf> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
t1e1 mode [e1|t1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D key WORD port <1-65535> . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D key WORD port <1-65535> timeout <1-30> . . . .
tacacs-server host A.B.C.D key WORD timeout <1-30> . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D key WORD timeout <1-30> port <1-65535> . . . .
tacacs-server host A.B.C.D name WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D port <1-65535> key WORD . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D port <1-65535> key WORD timeout <1-30> . . . .
tacacs-server host A.B.C.D port <1-65535> timeout <1-30> . . . . . . . . . . . . . .
tacacs-server host A.B.C.D port <1-65535> timeout <1-30> key WORD . . . .
tacacs-server host A.B.C.D sequence-number <0-4> . . . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D timeout <1-30> key WORD . . . . . . . . . . . . . . . . .
tacacs-server host A.B.C.D timeout <1-30> key WORD port <1-65535> . . . .
tacacs-server host A.B.C.D timeout <1-30> port <1-65535> . . . . . . . . . . . . . .
tacacs-server host A.B.C.D timeout <1-30> port <1-65535> key WORD . . . .
tacacs-server key WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tacacs-server port <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tacacs-server timeout <1-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
temperature-sensor <shelf/slot/sensor> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tl1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice class-of-service WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice conference local originator flashhook [drop|ignore|split] . . . . . . . . . . . .
voice conference mode [local|network] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan 900-number <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan always-permitted <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan internal <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan international <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan local <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan national <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan operator-assisted <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan specify-carrier <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan toll-free <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan user1 <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan user2 <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice dial-plan user3 <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice flashhook mode [interpreted|transparent] . . . . . . . . . . . . . . . . . . . . . . . .
voice sip-trunk <Txx> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice spre <PATTERN> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
voice user NUMBER:20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1925
2-1926
2-1927
2-1928
2-1929
2-1930
2-1931
2-1932
2-1933
2-1934
2-1935
2-1936
2-1937
2-1938
2-1939
2-1940
2-1941
2-1942
2-1943
2-1944
2-1945
2-1946
2-1947
2-1948
2-1949
2-1950
2-1951
2-1952
2-1953
2-1954
2-1955
2-1956
2-1957
2-1958
2-1959
2-1960
2-1961
2-1962
2-1963
2-1964
2-1965
2-1966
2-1967
2-1968

GPON Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-1969


activation-mode [auto-activate|auto-discover|manual|registration] . . . . . . . . . 2-1970

6TANV57CLI-35A

Contents

exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
fec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
range [extended|maximum|standard] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host <1-64> ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . .
subtended-host <1-64> ip address dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host <1-64> ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . .
subtended-host <1-64> s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host <1-64> s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1971
2-1972
2-1973
2-1974
2-1975
2-1976
2-1977
2-1978
2-1979

HDSL2 Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . 2-1980


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
loopback local line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-loopback niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds loop-attenuation <0-127> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds snr-margin <0-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
timeout loopback [2-hour|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1981
2-1982
2-1983
2-1984
2-1985
2-1986
2-1987
2-1988
2-1989
2-1990
2-1991
2-1992
2-1993
2-1994

HDSL4 Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . 2-1995


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
loopback local line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-loopback niu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds loop-attenuation <0-127> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds snr-margin <0-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
timeout loopback [2-hour|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-1996
2-1997
2-1998
2-1999
2-2000
2-2001
2-2002
2-2003
2-2004
2-2005
2-2006
2-2007
2-2008
2-2009

IP Host Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . 2-2010


connect interface packet-timing <shelf/slot> . . . . . . . . . . . . . . . . . . . . . . . . . .
connect interface pseudowire [<shelf/slot/pwe>|<remote-index>] . . . . . . . . . .
connect service [mgcp|sip] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
domain-lookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
domain-name WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6TANV57CLI-35A

2-2011
2-2012
2-2013
2-2014
2-2015
2-2016

li

Total Access/NetVanta Carrier CLI Dictionary

exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
name-server A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
name-server A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2017
2-2018
2-2019
2-2020
2-2021
2-2022

IPACL Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2023


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
permit A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
permit A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
permit host A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2024
2-2025
2-2026
2-2027

Line Admin Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . 2-2028


dcd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dtr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
flow-control [hardware|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mode [cli|menus|terminal-server|tl1|tl1-test] . . . . . . . . . . . . . . . . . . . . . . . . . .
speed [115200|19200|38400|57600|9600] . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2029
2-2030
2-2031
2-2032
2-2033
2-2034

Line Console Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . 2-2035


description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
dtr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
speed [115200|19200|38400|57600|9600|auto] . . . . . . . . . . . . . . . . . . . . . . .

2-2036
2-2037
2-2038
2-2039

Line Network Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . 2-2040


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2041
mode [accessory-option|cli|menus|terminal-server|tl1] . . . . . . . . . . . . . . . . . . 2-2042
speed [115200|19200|38400|57600|9600] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2043

Link Aggregation Group Interface Configuration Command Set . . . . 2-2044


active-links-minimum <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm enable active-links-minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alias WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2045
2-2046
2-2047
2-2048
2-2049
2-2050
2-2051
2-2052

Muxponder Highspeed Interface Configuration Command Set . . . . . . 2-2053


alarm enable [downstream-fault|heartbeat-loss|lacp-timeout|link-down-enterprise|linkdown-rfc2863|port-mode|upstream-node] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2055
alarm enable pluggable [fault|missing|speed-mismatch|temperature-high|unknown] .
2-2056
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2057
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2058
downlink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2059
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2060

lii

6TANV57CLI-35A

Contents

ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


ethernet cfm mep <1-8191> WORD WORD down . . . . . . . . . . . . . . . . . . . . .
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lacp grammar standby-aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lacp mode [active|passive] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mtu <1500-10000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . .
subtended-host mode [disabled|sender] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . .
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . .
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . .
subtended-host s-tag [<1-4094>|system-management-evc] . . . . . . . . . . . . . .
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds broadcasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . .
thresholds broadcasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds giants 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds giants 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds multicasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . .
thresholds multicasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . .
thresholds runts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds runts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2061
2-2062
2-2063
2-2064
2-2065
2-2066
2-2067
2-2068
2-2070
2-2071
2-2072
2-2073
2-2074
2-2075
2-2076
2-2077
2-2078
2-2079
2-2080
2-2081
2-2082
2-2083
2-2084
2-2085
2-2086
2-2087
2-2088
2-2089
2-2090
2-2091

Muxponder Midspeed Interface Configuration Command Set. . . . . . . 2-2092


alarm enable [downstream-fault|heartbeat-loss|lacp-timeout|link-down-enterprise|linkdown-rfc2863|port-mode|upstream-node] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2094
alarm enable pluggable [fault|missing|speed-mismatch|temperature-high|unknown] .
2-2095
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2096
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2097
downlink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2098
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2099
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2100
ethernet cfm mep <1-8191> WORD WORD [down|up] . . . . . . . . . . . . . . . . . . 2-2101
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2102
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2103
full-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2104
half-duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2105
lacp grammar standby-aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2106
lacp mode [active|passive] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2107

6TANV57CLI-35A

liii

Total Access/NetVanta Carrier CLI Dictionary

link-state-awareness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2108
mac aging-time <0-3600> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2109
mac limit [<1-n>|disabled] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2110
mtu <1500-10000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2111
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2112
speed [10|100|1000|2500|auto] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2114
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2116
subtended-host ez-provisioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2117
subtended-host ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . 2-2118
subtended-host ip address dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2119
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2120
subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . . 2-2121
subtended-host mode [disabled|listener|sender] . . . . . . . . . . . . . . . . . . . . . . . 2-2122
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . . 2-2123
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . . 2-2124
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . . 2-2125
subtended-host snmp-server ez-provisioning host A.B.C.D traps version [1|2c] . . . 22126
subtended-host snmp-server location WORD . . . . . . . . . . . . . . . . . . . . . . . . . 2-2127
subtended-host s-tag [<1-4094>|inherit] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2128
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2129
thresholds broadcasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-2130
thresholds broadcasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-2131
thresholds discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-2132
thresholds discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-2133
thresholds errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-2134
thresholds errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2135
thresholds giants 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . 2-2136
thresholds giants 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2137
thresholds invalid-vlan 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . 2-2138
thresholds invalid-vlan 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . 2-2139
thresholds link-state-awareness bandwidth-minimum <0-2147483647> . . . . . 2-2140
thresholds link-state-awareness links-minimum <0-n> . . . . . . . . . . . . . . . . . . 2-2141
thresholds multicasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . 2-2142
thresholds multicasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . 2-2143
thresholds peak-mac-entries 15-minute <0-n> . . . . . . . . . . . . . . . . . . . . . . . . 2-2144
thresholds peak-mac-entries 24-hour <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2145
thresholds runts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . 2-2146
thresholds runts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2147

ONT Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2148


aes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
battery-monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
registration-id LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
serial-number LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

liv

2-2149
2-2150
2-2151
2-2152
2-2153
2-2154
2-2155

6TANV57CLI-35A

Contents

Packet Timing Interface Configuration Command Set . . . . . . . . . . . . . 2-2156


dscp <0-63> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mode [client|server] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
server ip address A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
server mac-address arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
type [inband|sntp|sntp-inband] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
uncorrelate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2157
2-2158
2-2159
2-2160
2-2161
2-2162
2-2163
2-2164
2-2165

Policer Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2166


cbs <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cir <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ebs <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
eir [<0-n>|max-bandwidth] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per custom evc-map WORD [egress|ingress] . . . . . . . . . . . . . . . . . . . . . . . . .
per evc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per mevc WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per mevc WORD ce-vlan-pri <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per uni efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per uni ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per uni gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per uni muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . .
per uni muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds green-discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . .
thresholds green-discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . .
thresholds green-total 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . .
thresholds green-total 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds red-total 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . .
thresholds red-total 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds yellow-discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . .
thresholds yellow-discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . .
thresholds yellow-total 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . .
thresholds yellow-total 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .

2-2167
2-2168
2-2169
2-2170
2-2171
2-2172
2-2173
2-2174
2-2175
2-2176
2-2177
2-2178
2-2179
2-2180
2-2181
2-2182
2-2183
2-2184
2-2185
2-2186
2-2187
2-2188
2-2189
2-2190
2-2191

Power Shedding Configuration Command Set . . . . . . . . . . . . . . . . . . . 2-2192


activation-delay <1-1440> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm level power-shed-state [alert|critical|information|major|minor] . . . . . . . .
deactivation-delay <1-1440> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
trigger external-input [<1-n>|aco] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
trigger remote-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2193
2-2194
2-2195
2-2196
2-2197
2-2198
2-2199

PPP Group Interface Configuration Command Set. . . . . . . . . . . . . . . . 2-2200


acfc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2201

6TANV57CLI-35A

lv

Total Access/NetVanta Carrier CLI Dictionary

active-links-minimum <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alias WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ethernet cfm mep <1-8191> WORD WORD up . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
link [<slot/port>|<slot/port:chan>] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lqm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
magic-number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-configure <2-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-failure <2-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-terminate <2-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip address A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip dhcp-client client-id WORD . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip dhcp-client client-id WORD hostname WORD . . . . . . . . . . . . .
peer default ip dhcp-client hostname WORD . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip dns A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
peer default ip dns A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
pfc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ppp authentication [chap|none] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ppp chap hostname WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ppp chap password WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ppp multilink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
restart-timer <1-30> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown unassigned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
username WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
username WORD password WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2202
2-2203
2-2204
2-2205
2-2206
2-2207
2-2208
2-2209
2-2210
2-2211
2-2212
2-2213
2-2214
2-2215
2-2216
2-2217
2-2218
2-2219
2-2220
2-2221
2-2222
2-2223
2-2224
2-2225
2-2226
2-2227
2-2228
2-2229

Protection Group Configuration Command Set . . . . . . . . . . . . . . . . . . 2-2230


add protect-module <slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
add working-module <slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alias WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
inhibit-switch <slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
priority <slot> <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
revertive <slot> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
wait-to-restore auto-switch <1-20> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
wait-to-restore manual-switch <slot> <1-10> . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2231
2-2232
2-2233
2-2234
2-2235
2-2236
2-2237
2-2238
2-2239

Pseudowire Circuit Emulation Interface Configuration Command Set 2-2240


connect e1 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
connect t1 [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
destination [<shelf/slot/port>|<remote-index>] . . . . . . . . . . . . . . . . . . . . . . . . .
destination ip address A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
destination ip udp-port <n-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
destination mac-address arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

lvi

2-2241
2-2242
2-2243
2-2244
2-2245
2-2246
2-2247

6TANV57CLI-35A

Contents

dscp <0-63> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
jitter-buffer-depth <1-100> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mode [advanced|basic] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
payload-size <25-958> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
rtp frequency <8-13200> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
rtp payload-type <96-127> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
source ip udp-port <n-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
type satop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2248
2-2249
2-2250
2-2251
2-2252
2-2253
2-2254
2-2255
2-2256
2-2257

Queue Configuration Command Set. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2258


algorithm [sred|wred] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cos <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
drop-probability green <0-100> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
drop-probability yellow <0-100> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-depth <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sred green minimum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sred yellow minimum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds wred green maximum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds wred green minimum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds wred yellow maximum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds wred yellow minimum <1-255> . . . . . . . . . . . . . . . . . . . . . . . . . . .
weight [<1-100>|dynamic] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2259
2-2260
2-2261
2-2262
2-2263
2-2264
2-2265
2-2266
2-2267
2-2268
2-2269
2-2270
2-2271

Redundancy Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . 2-2272


alarm enable [auto-switch|card-active|database-sync|manual-switch|protectionunavailable|switch-to-protect] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2273
alarm enable peer [mirror|version] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2274
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2275
revertive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2276
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2277
wait-to-restore <15-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2278

Relay Test Application Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2279


activate audible-relay [critical|major|minor] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2280
activate visual-relay [critical|major|minor] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2281
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2282

RFVideo Interface Configuration Command Set . . . . . . . . . . . . . . . . . . 2-2283


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2284
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2285
video-return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2286

SCA Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2287


autosave . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-instances <1-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
permit-restore [controller|modules] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6TANV57CLI-35A

2-2288
2-2289
2-2290
2-2291

lvii

Total Access/NetVanta Carrier CLI Dictionary

permit-restore controller [sca|security|snmp] . . . . . . . . . . . . . . . . . . . . . . . . . .


permit-restore controller network [general|interface] . . . . . . . . . . . . . . . . . . . .
permit-restore modules [<shelf/slot>|empty-slots|in-service] . . . . . . . . . . . . . .
prefix WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
retries <0-99> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
schedule <HH:MM> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
suffix WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
update-only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2292
2-2293
2-2294
2-2295
2-2296
2-2297
2-2298
2-2299

Security Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2300


account-expiration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
advisory-warning [message|tl1] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm enable [account-expiration|lock-out] . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm enable login [console|failure|success] . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm level login console [alert|critical|information|major|minor] . . . . . . . . . . .
alarm level login failure [alert|critical|information|major|minor] . . . . . . . . . . . .
alarm level login success [alert|critical|information|major|minor] . . . . . . . . . . .
case-sensitive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lock-out duration <1-60> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lock-out failures <2-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lock-out indefinite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
multiple-logins . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
notification <0-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
password [complexity|digit|expiration|lowercase|no-digit-start-end|notlast|special|uppercase] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
password length <6-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
snmp-access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
system-privilege [admin|config|read-only|read-write|test] . . . . . . . . . . . . . . . .
user-lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
username WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2301
2-2302
2-2303
2-2304
2-2305
2-2306
2-2307
2-2308
2-2309
2-2310
2-2311
2-2312
2-2313
2-2314
2-2315
2-2317
2-2318
2-2319
2-2320
2-2321

Shaper Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2322


burst <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per interface atm [<shelf/slot/port>|<shelf/slot/port.sub>] . . . . . . . . . . . . . . . .
per interface efm-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . . . . .
per interface efm-port <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per interface ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
per interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . .
per interface gpon <remote-index> channel <1> . . . . . . . . . . . . . . . . . . . . . . .
per interface muxponder-highspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . .
per interface muxponder-midspeed <shelf/slot/port> . . . . . . . . . . . . . . . . . . .
per remote-device <remote-index> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
queues <0-7>|LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
rate <0-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2323
2-2324
2-2325
2-2326
2-2327
2-2328
2-2329
2-2330
2-2331
2-2332
2-2333
2-2334
2-2335
2-2336

SHDSL Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . 2-2337

lviii

6TANV57CLI-35A

Contents

alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


annex [a|a-efm|a-or-b|a-or-b-efm|b|b-efm|efm] . . . . . . . . . . . . . . . . . . . . . . . .
constellation crossover-rate <12-60> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
diagnostics loop-locator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
diagnostics splice-detect distance-type [feet|meters] . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
linerate adaptive [g991-2|max-rate|t1-417] . . . . . . . . . . . . . . . . . . . . . . . . . . .
linerate adaptive <3-89> <-10-20> [current-condition|worstcase-condition] . .
linerate adaptive g991-2 [nl|us] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
linerate fixed <3-89> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
power-back-off [<0-31>|auto] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvc 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvc 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds loop-attenuation <0-127> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds losws 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds losws 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds snr-margin <0-15> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2338
2-2339
2-2340
2-2341
2-2342
2-2343
2-2344
2-2345
2-2346
2-2347
2-2348
2-2349
2-2350
2-2352
2-2353
2-2354
2-2355
2-2356
2-2357
2-2358
2-2359
2-2360
2-2361
2-2362
2-2363

SIP Trunk Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . 2-2364


dial-string source [request-uri|to] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
domain WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip authenticate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar alert-info url WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar from host [domain|local|sip-proxy] . . . . . . . . . . . . . . . . . . . . . . .
sip grammar request-uri host [domain|sip-outbound-proxy|sip-proxy] . . . . . . .
sip grammar request-uri host-resolve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar require 100rel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar supported 100rel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar to host [domain|sip-proxy] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip grammar user-agent [LINE|default|none] . . . . . . . . . . . . . . . . . . . . . . . . . .
sip keep-alive interval <30-3600> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip keep-alive method [info|none|options] . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip outbound-proxy primary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . . . . .
sip outbound-proxy primary [A.B.C.D|WORD] udp . . . . . . . . . . . . . . . . . . . . .
sip outbound-proxy primary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . . . .
sip outbound-proxy secondary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . .
sip outbound-proxy secondary [A.B.C.D|WORD] udp . . . . . . . . . . . . . . . . . . .
sip outbound-proxy secondary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . .

6TANV57CLI-35A

2-2366
2-2367
2-2368
2-2369
2-2370
2-2371
2-2372
2-2373
2-2374
2-2375
2-2376
2-2377
2-2378
2-2379
2-2380
2-2381
2-2382
2-2383
2-2384
2-2385

lix

Total Access/NetVanta Carrier CLI Dictionary

sip proxy primary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


sip proxy primary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . . . . . . . . . . . .
sip proxy secondary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip proxy secondary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . . . . . . . . . .
sip registrar expire-time <30-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar max-concurrent-reg <1-32> . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar primary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar primary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . . . . . . . . . .
sip registrar require-expires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar secondary [A.B.C.D|WORD] . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar secondary [A.B.C.D|WORD] udp . . . . . . . . . . . . . . . . . . . . . . . . .
sip registrar secondary [A.B.C.D|WORD] udp <0-65535> . . . . . . . . . . . . . . . .
sip timer invite-failure rollover <1-32> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip timer registration-failure retry <10-604800> . . . . . . . . . . . . . . . . . . . . . . . .

2-2386
2-2387
2-2388
2-2389
2-2390
2-2391
2-2392
2-2393
2-2394
2-2395
2-2396
2-2397
2-2398
2-2399

System Alarm Configuration Command Set . . . . . . . . . . . . . . . . . . . . . 2-2400


alarm aid external-input <1-n> <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2401
alarm aid power-fail ac <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2402
alarm aid power-fail dc a <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2403
alarm aid power-fail dc b <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2404
alarm condition-code external-input <1-n> WORD . . . . . . . . . . . . . . . . . . . . . 2-2405
alarm condition-code power-fail ac WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2406
alarm condition-code power-fail dc a WORD . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2407
alarm condition-code power-fail dc b WORD . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2408
alarm description external-input <1-n> WORD . . . . . . . . . . . . . . . . . . . . . . . . 2-2409
alarm description power-fail ac WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2410
alarm enable [bandwidth-unavailable|downstream-node|duplicate-nodenumber|duplicate-scm-ip|internal-system-s-tag|node-number|power-limit|ringgenerator] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2411
alarm enable external-input <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2412
alarm enable module [comm-failure|removed|restart] . . . . . . . . . . . . . . . . . . . 2-2413
alarm enable power-fail ac . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2414
alarm enable power-fail dc [a|b] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2415
alarm enable shelf <2-4> [link-down|link-removed] . . . . . . . . . . . . . . . . . . . . . 2-2416
alarm enable test audible-relay [critical|major|minor] . . . . . . . . . . . . . . . . . . . 2-2417
alarm enable test visual-relay [critical|major|minor] . . . . . . . . . . . . . . . . . . . . . 2-2418
alarm level external-input <1-n> [alert|critical|information|major|minor] . . . . . 2-2419
alarm level module removed [critical|major|minor] . . . . . . . . . . . . . . . . . . . . . 2-2421
alarm level power-fail ac [alert|critical|information|major|minor] . . . . . . . . . . . 2-2422
alarm level power-fail dc a [alert|critical|information|major|minor] . . . . . . . . . . 2-2423
alarm level power-fail dc b [alert|critical|information|major|minor] . . . . . . . . . . 2-2424
alarm level switch removed [critical|major|minor] . . . . . . . . . . . . . . . . . . . . . . 2-2425
chronology [ascending|descending] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2426
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2427

System Management EVC Configuration Command Set . . . . . . . . . . . 2-2428


connect men-port efm-group [<shelf/slot/group>|WORD] . . . . . . . . . . . . . . . . 2-2429
connect men-port ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2430

lx

6TANV57CLI-35A

Contents

connect men-port gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . .


connect men-port lag-group <shelf/slot/group> . . . . . . . . . . . . . . . . . . . . . . . .
connect uni ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
connect uni gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address [A.B.C.D|dhcp] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
men-pri <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s-tag <1-4094> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2431
2-2432
2-2433
2-2434
2-2435
2-2436
2-2437
2-2438
2-2439
2-2440

System Privilege Security Configuration Command Set . . . . . . . . . . . 2-2441


account-expiration <20-365> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2442
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2443
password-expiration <20-365> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2444

System Timing Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-2445


alarm enable source [primary-failed|secondary-failed|switch] . . . . . . . . . . . . . 2-2447
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2448
external primary hop-count <0-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2449
external primary priority <0-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2450
external primary quality [do-not-use|sonet|synchronized|transit] . . . . . . . . . . . 2-2451
external primary quality stratum [1|2|3|3e|4] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2452
external primary type [bits-d4|bits-g704|bits-ones-density|composite|composite-npbo]
2-2453
external secondary hop-count <0-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2454
external secondary priority <0-255> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2455
external secondary quality [do-not-use|sonet|synchronized|transit] . . . . . . . . 2-2456
external secondary quality stratum [1|2|3|3e|4] . . . . . . . . . . . . . . . . . . . . . . . . 2-2457
external secondary type [bits-d4|bits-g704|bits-ones-density|composite|compositenpbo] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2458
revertive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2459
revertive hop-count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2460
source fallback external [primary|secondary] . . . . . . . . . . . . . . . . . . . . . . . . . 2-2461
source fallback interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . 2-2462
source fallback interface gigabit-ethernet <shelf/slot/port> fixed . . . . . . . . . . . 2-2463
source fallback interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . 2-2464
source fallback interface ten-gigabit-ethernet <shelf/slot/port> fixed . . . . . . . . 2-2465
source fallback internal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2466
source fallback loop-a interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . 2-2467
source fallback loop-b interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . 2-2468
source primary external [primary|secondary] . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2469
source primary interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . . . . 2-2470
source primary interface gigabit-ethernet <shelf/slot/port> fixed . . . . . . . . . . . 2-2471
source primary interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . 2-2472
source primary interface ten-gigabit-ethernet <shelf/slot/port> fixed . . . . . . . . 2-2473
source primary internal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2474
source primary loop-a interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . 2-2475

6TANV57CLI-35A

lxi

Total Access/NetVanta Carrier CLI Dictionary

source primary loop-b interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . .


source secondary external [primary|secondary] . . . . . . . . . . . . . . . . . . . . . . .
source secondary interface gigabit-ethernet <shelf/slot/port> . . . . . . . . . . . . .
source secondary interface gigabit-ethernet <shelf/slot/port> fixed . . . . . . . .
source secondary interface ten-gigabit-ethernet <shelf/slot/port> . . . . . . . . . .
source secondary interface ten-gigabit-ethernet <shelf/slot/port> fixed . . . . .
source secondary internal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
source secondary loop-a interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . .
source secondary loop-b interface t3 <shelf/slot/port> . . . . . . . . . . . . . . . . . .

2-2476
2-2477
2-2478
2-2479
2-2480
2-2481
2-2482
2-2483
2-2484

T1 Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . 2-2485


alarm enable [ais|lof|los|rai] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm level ais [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . .
alarm level lof [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . . .
alarm level los [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . .
alarm level rai [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . . .
alarm trap [ais|lof|los|rai] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service timeout <1-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock source [internal|line] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
coding [ami|b8zs] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
framing [d4|esf] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lbo long [0|15|7] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lbo short <0-655> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-loopback [csu|fdl|feac|niu] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-p 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-p 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds ses-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
timeout loopback <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2487
2-2488
2-2489
2-2490
2-2491
2-2492
2-2493
2-2494
2-2495
2-2496
2-2497
2-2498
2-2499
2-2500
2-2501
2-2502
2-2503
2-2504
2-2506
2-2507
2-2508
2-2509
2-2510
2-2511
2-2512
2-2513
2-2514
2-2515
2-2516
2-2517
2-2518

T3 Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . 2-2519


alarm enable [ais|lof|los|rai] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
alarm level ais [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . .
alarm level lof [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . . .

lxii

2-2521
2-2522
2-2523
2-2524

6TANV57CLI-35A

Contents

alarm level los [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . .


alarm level rai [alert|critical|information|major|minor] . . . . . . . . . . . . . . . . . . . .
alarm trap [ais|lof|los|rai] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
auto-in-service timeout <1-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
clock source [internal|line] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
framing [cbit|m23] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
remote-loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvcp-p 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvcp-p 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cv-l 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvp-p 15-minute <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds cvp-p 24-hour <0-2147483647> . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds escp-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds escp-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds es-l 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds esp-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds esp-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sefs-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sefs-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sescp-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sescp-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sesp-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds sesp-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds uas-p 24-hour <0-86400> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
timeout loopback <0-9999> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2525
2-2526
2-2527
2-2528
2-2529
2-2530
2-2531
2-2532
2-2533
2-2534
2-2535
2-2537
2-2538
2-2539
2-2540
2-2541
2-2542
2-2543
2-2544
2-2545
2-2546
2-2547
2-2548
2-2549
2-2550
2-2551
2-2552
2-2553
2-2554
2-2555
2-2556
2-2557

Temperature Sensor Configuration Command Set. . . . . . . . . . . . . . . . 2-2558


exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2559

Ten Gigabit-Ethernet Interface Configuration Command Set . . . . . . . 2-2560


alarm enable [downstream-fault|heartbeat-loss|lacp-timeout|link-down-enterprise|linkdown-rfc2863|port-mode|upstream-node] . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2562
alarm enable pluggable [fault|missing|speed-mismatch|temperature-high|unknown] .
2-2563
alarm enable shutdown maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2564
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2565
downlink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2566
ethernet [cfm|evc-advertisement] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2567
ethernet cfm enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2568
ethernet cfm mep <1-8191> WORD WORD down . . . . . . . . . . . . . . . . . . . . . 2-2569
ethernet oam enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2570

6TANV57CLI-35A

lxiii

Total Access/NetVanta Carrier CLI Dictionary

exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lacp grammar standby-aggregation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lacp mode [active|passive] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mtu <1500-10000> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
s-tag-dei . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip address A.B.C.D A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip default-gateway A.B.C.D . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host ip file-server default host A.B.C.D . . . . . . . . . . . . . . . . . . . . .
subtended-host mode [disabled|sender] . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
subtended-host snmp-server chassis-id WORD . . . . . . . . . . . . . . . . . . . . . . .
subtended-host snmp-server community read-only WORD . . . . . . . . . . . . . .
subtended-host snmp-server community read-write WORD . . . . . . . . . . . . . .
subtended-host s-tag [<1-4094>|system-management-evc] . . . . . . . . . . . . . .
subtended-host s-tag-priority <0-7> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds broadcasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . .
thresholds broadcasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds discards 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . .
thresholds discards 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds errors 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds errors 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds giants 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . .
thresholds giants 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds multicasts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . .
thresholds multicasts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . .
thresholds runts 15-minute <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . .
thresholds runts 24-hour <0-4294967295> . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2571
2-2572
2-2573
2-2574
2-2575
2-2577
2-2578
2-2579
2-2580
2-2581
2-2582
2-2583
2-2584
2-2585
2-2586
2-2587
2-2588
2-2589
2-2590
2-2591
2-2592
2-2593
2-2594
2-2595
2-2596
2-2597
2-2598

TL1 Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2599


chassis-id-tid-sync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
echo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
equipment-id <0-9> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
log-max <25-200> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
tid WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2600
2-2601
2-2602
2-2603
2-2604
2-2605

TWAMP Responder Configuration Command Set . . . . . . . . . . . . . . . . 2-2606


control source-port [<1-65535>|twamp-control] . . . . . . . . . . . . . . . . . . . . . . . .
control timeout <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
max-sessions <1-n> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
test timeout <1-65535> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2-2607
2-2608
2-2609
2-2610
2-2611
2-2612

Username Security Configuration Command Set . . . . . . . . . . . . . . . . . 2-2613


account-expiration [<20-365>|enable] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
lock-out . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

lxiv

2-2614
2-2616
2-2617
2-2618

6TANV57CLI-35A

Contents

password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2619
password-expiration [<20-365>|enable] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2620
privilege [admin|config|read-only|read-write|test] . . . . . . . . . . . . . . . . . . . . . . 2-2621

VDSL Interface Configuration Command Set . . . . . . . . . . . . . . . . . . . . 2-2622


alarm enable link-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2624
deployment region <1-2> scenario <1-2> other-service <0-4> application-standard <13> band-plan <1> band-profile <1-7> psd-u0 <1-2> psd-mask . . . . . . . . . . . 2-2625
description LINE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2627
dmt-options hamband-notch [1.8|10.1|14.0|18.06|21.00|24.89|28.00|3.5|7.0] 2-2628
dmt-options snr-margin downstream maximum <0-31> . . . . . . . . . . . . . . . . . 2-2630
dmt-options snr-margin downstream minimum <0-31> . . . . . . . . . . . . . . . . . . 2-2631
dmt-options snr-margin downstream target <0-31> . . . . . . . . . . . . . . . . . . . . . 2-2632
dmt-options snr-margin upstream maximum <0-31> . . . . . . . . . . . . . . . . . . . . 2-2633
dmt-options snr-margin upstream minimum <0-31> . . . . . . . . . . . . . . . . . . . . 2-2634
dmt-options snr-margin upstream target <0-31> . . . . . . . . . . . . . . . . . . . . . . . 2-2635
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2636
latency-path delay downstream <0-1> <1-63> . . . . . . . . . . . . . . . . . . . . . . . . 2-2637
latency-path delay upstream <0-1> <1-63> . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2639
latency-path init-policy downstream <0-1> [data-rate|inp] . . . . . . . . . . . . . . . . 2-2641
latency-path init-policy upstream <0-1> [data-rate|inp] . . . . . . . . . . . . . . . . . . 2-2643
latency-path inp downstream <0-1> <0-16> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2645
latency-path inp upstream <0-1> <0-16> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2647
latency-path payload-rate downstream maximum <0-1> <32-150000> . . . . . 2-2649
latency-path payload-rate downstream minimum <0-1> <32-150000> . . . . . . 2-2651
latency-path payload-rate upstream maximum <0-1> <32-96000> . . . . . . . . . 2-2653
latency-path payload-rate upstream minimum <0-1> <32-96000> . . . . . . . . . 2-2655
latency-path type downstream <0-1> [fast|interleave|no-channel] . . . . . . . . . 2-2657
latency-path type upstream <0-1> [fast|interleave|no-channel] . . . . . . . . . . . . 2-2659
power-back-off upstream [a|auto|b|c|custom|d|disable|e|f] . . . . . . . . . . . . . . . 2-2661
rate-adaption downstream [fixed|startup] . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2663
rate-adaption upstream [fixed|startup] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2664
service-mode [adsl2|adsl2+|adsl2+m|adsl2-multimode|g-dmt|vdsl2] . . . . . . . 2-2665
shutdown [maintenance|unassigned] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2667
thresholds es downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-2669
thresholds es upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2670
thresholds lof downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-2671
thresholds lof upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2672
thresholds lol upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2673
thresholds los downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . 2-2674
thresholds los upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2675
thresholds lprs downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . 2-2676
thresholds lprs upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . 2-2677
thresholds ses downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . 2-2678
thresholds ses upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . 2-2679
thresholds snr downstream <0-99> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2680
thresholds snr upstream <0-99> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2681
thresholds uas downstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . 2-2682

6TANV57CLI-35A

lxv

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas upstream 15-minute <0-900> . . . . . . . . . . . . . . . . . . . . . . . . . 2-2683

Voice Class of Service Configuration Command Set . . . . . . . . . . . . . . 2-2684


call-privilege [900-number|all|internal|international|local|national|operatorassisted|specify-carrier|toll-free|user1|user2|user3] . . . . . . . . . . . . . . . . . . . . 2-2685
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2686

Voice User Configuration Command Set . . . . . . . . . . . . . . . . . . . . . . . . 2-2687


connect fxs <shelf/slot/port> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cos WORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip-identity WORD <Txx> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip-identity WORD <Txx> register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
sip-identity WORD <Txx> register auth-name WORD password WORD . . . .

lxvi

2-2688
2-2689
2-2690
2-2691
2-2692
2-2693

6TANV57CLI-35A

Tables

Tables
Table Intro-1.Topic List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro-1
Table Intro-2.Section Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intro-2
Table 1-1.Section 1 Topics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Table 1-2.Command Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Table 1-3.CLI Shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Table 1-4.Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5
Table 1-5.Input Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

6TANV57CLI-35A

xi

Total Access/NetVanta Carrier CLI Dictionary

xii

6TANV57CLI-35A

Introduction

Scope of this Guide


ThisguideisaCommandLineInterface(CLI)DictionaryfortheTotalAccess/NetVanta
Carrierproducts.Thisdocumentprovidesdetailedinformationaboutallcommandsthatare
availablethroughtheproducts.Someinformationandcommandsarenotapplicabletoall
products.

In this Guide
ThisguidecontainsthetopicslistedinTableIntro1.

Table Intro-1. Topic List

6TANV57CLI-35A

Section

Topic

Scope

Section1

UnderstandingCLI

Thissectionprovidesdetailsonhowto
usetheCommandLineInterfaceandthe
CLIDictionary.

Section2

Commands

Thissectionprovidesinformationabout
allofthecommandsthatareavailable
throughtheTotalAccess/NetVantaCarrier
products.

Intro-1

Total Access/NetVanta Carrier CLI Dictionary

Command Description Layout


TableIntro2liststhesectiondescriptionsfortheCLIcommands.Notallsectionsareappli
cabletoeverycommand.
Total Access/NetVanta Carrier CLI Dictionary

clock set <HH:MM:SS> <1-31> MONTH <2000-2036>

Use the clock set <HH:MM:SS> <1-31> WORD <2000-2036> command to set the current time
in 24-hour format and date.

Syntax Description
<2000-2036>

Year

Usage Examples

The following is an example of how to use the clock set <HH:MM:SS> <1-31> MONTH <20002036> command.
(config)#clock set 11:30:00 8 November 2008
(config)#

Functional Notes
Use the <HH:MM:SS> input the set the current time in 24-hour format.
Use the <1-31> input to set the current date (valid range: 1 to 31).
Use the WORD input to set the current month.
The valid range for the year is 2000 to 2036.

8
9

Local Security Permissions


Admin, Tech-Support
TACACS+ Levels
Level 15
Supported Products
SCM (1187010L1), NV 838 (1200633G4), NV 838 EP (1172839G1), NV 838 OSP (1172830G1)
Command ID
64890

Table Intro-2. Section Descriptions

Intro-2

Section

Description

Command

Thecommand,asitshouldbeentered,appearsonthetopline.Thebrackets<>
orallcapsdesignateaninput.Thebrackets[]designateasetofoptionsand
eachoptionisseparatedbyaverticalline|.Useonlyoneoptionfromwithin
thebrackets[]forthecommand.Donotincludethebracketsorverticallines
whentypingthecommand.

Command
Description

Thecommanddescriptiondescribestheuseandfunctionofthecommand
withinthesystem.

Syntax
Description

Thesyntaxdescriptionbrieflydescribesanyinputsandoptionsthatcanbe
enteredwiththecommand.

6TANV57CLI-35A

Introduction, - Command Description Layout

Table Intro-2. Section Descriptions (Continued)

6TANV57CLI-35A

Section

Description

Usage
examples

Theusageexamplesareexamplesofthecommandpromptandkeyboard
input.

Functional
Notes

Thefunctionalnotesareadditionalinformationlikedefaultvalues,valid
ranges,andadditionalsyntaxdescriptions.

LocalSecurity
Permissions

Thelocalsecuritypermissionslistthesecuritypermissionssetupforthe
command.

TACACS+
Levels

TheTACACS+levelslisttheTACACS+levelsforthecommand.

Supported
Products

Thesupportedproductslisttheproductsthatsupportthecommand.

CommandID

ThecommandIDisanADTRANspecificcommandIDnumberthatcanbe
usedwhenreferencingaspecificcommandwithADTRANsupport.

Intro-3

Total Access/NetVanta Carrier CLI Dictionary

Intro-4

6TANV57CLI-35A

Section 1
Understanding CLI
Scope of this Section
ThissectionprovidesdetailsonhowtousetheCommandLineInterfaceandtheCLI
Dictionary.

In this Section
ThissectioncontainsthetopicslistedinTable11.

Table 1-1. Section 1 Topics

6TANV57CLI-35A

Topic

See Page

AccessingtheCommandLineInterface

12

CommandModes

13

CLIShortcuts

14

CLIErrorMessages

15

CLIInputDescriptions

16

1-1

Total Access/NetVanta Carrier CLI Dictionary

Accessing the Command Line Interface


AccessthemanagementandprovisioningfeaturesfortheTotalAccess/NetVantaCarrier
productsbyCLIusingastandardDB9serialcabletoconnecttotheconsoleportlocatedon
theunit.Also,accesstheCLIthroughTelnet.
ToestablishCLIcommunicationwiththeproduct,performthefollowingsteps:
1.ConnecttothecraftinterfaceusingaVT100terminalorPCwithVT100emulationsoft
wareconfiguredwiththefollowingparameters:
Anyofthefollowingbaudrates:9600,19200,38400,57600,or115200
8databits
Noparity
1stopbit
Noflowcontrol
2. Onceconnected,pressENTERseveraltimestoaccesstheCLI.

Security Login
TheTotalAccess/NetVantaCarrierproductsareprotectedbyausernameandpassword.The
defaultusernameisADMIN,andthedefaultpasswordisPASSWORD.Configurethe
usernamesandpasswordsintheSecurityConfigurationCommandSet.

1-2

6TANV57CLI-35A

Section 1, Understanding CLI - Command Modes

Command Modes
TheTotalAccess/NetVantaCarrierCLIhasthreecommandmodes,Basic,Application,and
Enable.Eachmodesupportsaspecificsetofcommands.Forexample,allinterfaceconfigu
rationcommandsareaccessibleonlythroughtheEnablemode.Table12showsabrief
descriptionofeachcommandmode.

Table 1-2. Command Modes


Mode

Access by...

Prompt

With this mode...

Basic

Beginningasession

>

Displaysystem
informationandshow
statusorstatistics

Enable

EnteringEnablemode
whileintheBasic
modeasfollows:

Managerunning
configurations,enter
anyconfiguration
modes,andview
securitysettings

Copysystem
provisioningand
executestandardtest
procedures

>enable
Application

6TANV57CLI-35A

Performingacommon
functionwitha
reducedsetof
commands

1-3

Total Access/NetVanta Carrier CLI Dictionary

CLI Shortcuts
UsetheCLIshortcutstohelpconfiguretheproduct.Table13providesalistoftheCLI
shortcuts.

Table 1-3. CLI Shortcuts


Shortcut

Description

UparroworCTRL + P

Usetheuparrowtoredisplayapreviouslyenteredcommand.Theup
arrowcancyclethroughallcommandsenteredstartingwiththemost
recentcommand.

TAB

Afterenteringapartial,butunique,command,presstheTABtocomplete
thecommand.Thecommanddisplaysonthecommandpromptandwaits
forinput.

Usethe?foranyofthefollowing:
Displayalistofallsubcommandsinthecurrentmode.
Displayalistofavailablecommandsbeginningwithcertainletter(s).
Obtainsyntaxhelpforaspecificcommandbyenteringthecommand,a
space,andthenaquestionmark(?).TheCLIdisplaystherangeof
valuesandabriefdescriptionofthenextparameterexpectedforthat
particularcommand.

1-4

CTRL + A

UseCTRL + Atojumptothebeginningofthedisplayedcommandline.

CTRL + E

UseCTRL + Etojumptotheendofthedisplayedcommandline.

CTRL + U

UseCTRL + Utoclearthecurrentdisplayedcommandline.

Autofinish

Enterenoughletterstoidentifyacommandasunique.Forexample,
enteringint eth 1attheGlobalConfigurationpromptprovidesaccess
totheconfigurationparametersforthespecifiedEthernetinterface.

6TANV57CLI-35A

Section 1, Understanding CLI - CLI Error Messages

CLI Error Messages


Table14listsanddefinessomeofthemorecommonerrormessagesgivenintheCLI.

Table 1-4. Error Messages

6TANV57CLI-35A

Message

Helpful Hints

%Ambiguouscommand

Thismessageoccurswhenmultiplecommandscanbederived
fromtheinput.Tryusingthe?commandtodeterminethe
error.RefertoCLIShortcutsonpage 14formoreinformation.

%Unrecognizedcommand

Thismessageoccurswhenasinglecommandisenteredthatfails
tomatchanysupportedcommands.Tryusingthe?command
todeterminetheerror.RefertoCLIShortcutsonpage 14for
moreinformation.

%Invalidorincomplete
command

Thismessageoccurswhenthecommandisnotproperly
finished.Tryusingthe?commandtodeterminetheerror.
RefertoCLIShortcutsonpage 14formoreinformation.

%Invalidinputdetectedat^
marker

Theerrorincommandentryislocatedwherethecaret(^)mark
appears.Enteraquestionmarkattheprompt.Thesystem
displaysalistofapplicablecommandsorgivessyntax
informationfortheentry.

1-5

Total Access/NetVanta Carrier CLI Dictionary

CLI Input Descriptions


Table15listsanddefinestheinputsusedthroughouttheCLI.

Table 1-5. Input Descriptions

1-6

Input Syntax

Input
Example

<xy>

24000

Usethisinputtoenterarangebyenteringthexandy
variables.Thexandyvariablesarenumericandcanbe
negative.

<xn>

1n

Usethisinputtoenteraninfiniterangebyenteringthe
xvariable.Thexvariableisnumericandcanbe
negative.

<x>

Usethisinputtoenterasinglenumber.

<x,yz,a>

1,410,2022

Usethisinputtoenteracommadelimitednumericlist
withoutspaces.Thisinputcanincluderanges.

<HH:MM:SS>

12:30:01

Usethisinputtoenterthetimeinhourminutesecond
format.

<HH:MM>

12:30

Usethisinputtoenterthetimeinhourminuteformat.

MONTH

MAR

Usethisinputtoenterthemonth.Usethefullmonth
nameorthe3letterabbreviation.Thisinputisnotcase
sensitive.

HHH

010

Usethisinputtoenteranumerichex.Thenumberof
Hsdesignatesthenumberofhexdigitsallowed.

WORD

MAP_1

Usethisinputtoenterastringwithoutspaces.This
inputiscasesensitive.

LINE

MAP2

Usethisinputtoenterastringallowingspaces.This
inputiscasesensitive.

LIST

1,37,9,10

Usethisinputtoenteracommadelimitednumericlist
withoutspaces.Thisinputcanincluderanges.

<character>

Usethisinputtoenteranysinglealphacharacter.

Description

A.B.C.D

UsethisinputtoenteranIPaddress.

xx:xx:xx:xx:xx:xx

UsethisinputtoenteraMACaddress.

<shelf/slot/port>

1/1/1

Usethisinputtoentertheshelf,slot,andport.

<shelf/slot/WORD>

1/1/MAP

Usethisinputtoentertheshelf,slot,andWORD.

<shelf/slot>

1/S

Usethisinputtoentertheshelfandslot.

<shelf/WORD>

1/DEFAULT

UsethisinputtoentertheshelfandWORD.

<shelf>

Usethisinputtoentertheshelfnumber.Onlyshelf1is
supported.

6TANV57CLI-35A

Section 1, Understanding CLI - CLI Input Descriptions

Table 1-5. Input Descriptions (Continued)

6TANV57CLI-35A

Input Syntax

Input
Example

Description

<slot/port>

1/1

Usethisinputtoentertheslotandport.

<slot>

Usethisinputtoentertheslot.Validinputsare022for
moduleslots,AforSMA,BforSMB,SfortheSCU,
andFforthefanmodule.

<port>

Usethisinputtoentertheportnumber.

1-7

Total Access/NetVanta Carrier CLI Dictionary

1-8

6TANV57CLI-35A

Section 2
Commands
Scope of this Section
Thissectionprovidesinformationaboutallofthecommandsthatareavailablethroughthe
TotalAccess/NetVantaCarrierproducts.Somecommandsarenotapplicabletoallproducts.

Command Sets
TheTotalAccess/NetVantaCarrierCLIhasmanycommandsetstoorganizetheconfiguration
commands.Eachcommandsetsupportsasetofcommandsspecifictotheconfigurable
parametersforthemode.Anintroductionforeachcommandsetshowshowtoaccessthe
commandsetandabriefdescriptionofeachcommandset.

6TANV57CLI-35A

2-1

Total Access/NetVanta Carrier CLI Dictionary

Common Commands
Usethecommoncommandstoexecutegeneralcommandslikecopyandshow.Theextentof
thelistofcommandsavailableisdependentontheactiverealm.
ChassisId>enable
ChassisId#

ThefollowingisalistofcommandsavailableintheCommonCommands.
application
clear[arp|counters|nodeinformation]
cleararp<shelf/slot>
clearcounters[aaa|adsl|backplane|dynamiccounter|e1|efmgroup|efmlink|efm
port|erps|ethernet|evc|evcmap|framerelay|fxs|gigabit
ethernet|hdsl2|hdsl4|lacp|muxponderhighspeed|muxpondermidspeed|packet
timing|policer|pppgroup|ppplink|pseudowire|shdsl|t1|t3|tengigabitethernet|vdsl]
clearcountersaaa[local|radius|tacacs+]
clearcountersadsl<shelf/slot/port>
clearcountersbackplane<shelf/slot/port>
clearcountersdynamiccounter<shelf/slot/index>
clearcounterse1<shelf/slot/port>
clearcountersefmgroup<shelf/slot/group>
clearcountersefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]
clearcountersefmport<shelf/slot/port>
clearcounterserps<shelf/slot/ring>
clearcountersethernet[<shelf/slot/port>|cfm]
clearcountersethernetcfmassociationWORD
clearcountersethernetcfmdomainWORD
clearcountersethernetcfmdown
clearcountersethernetcfminterfaceefmgroup<shelf/slot/group>
clearcountersethernetcfminterfaceethernet<shelf/slot/port>
clearcountersethernetcfminterfacegigabitethernet<shelf/slot/port>
clearcountersethernetcfmlevel<07>
clearcountersethernetcfmmep<18191>
clearcountersethernetcfmvlan[<14094>|none]
clearcountersevcWORD
clearcountersevcWORD<shelf/slot>
clearcountersevcWORD<shelf/slot>ipigmp
clearcountersevcmapWORD<shelf/slot>
clearcountersframerelay[<shelf/slot/group>|dlci]
clearcountersframerelay<shelf/slot/group>dlci
clearcountersframerelay<shelf/slot/group>dlci<16991>

2-2

6TANV57CLI-35A

Section 2, Commands - Common Commands

clearcountersfxs<shelf/slot/port>
clearcountersgigabitethernet<shelf/slot/port>
clearcountershdsl2<shelf/slot/port>
clearcountershdsl4<shelf/slot/port>
clearcounterslacp<shelf/slot>
clearcountersmuxponderhighspeed<shelf/slot/port>
clearcountersmuxpondermidspeed<shelf/slot/port>
clearcounterspackettiming<shelf/slot>
clearcounterspolicerWORD
clearcounterspppgroup<shelf/slot/group>
clearcountersppplink[<shelf/slot/port>|<shelf/slot/port:chan>]
clearcountersproberespondertwamp
clearcounterspseudowire[<shelf/slot>|<shelf/slot/pwe>]
clearcountersshdsl<shelf/slot/port>
clearcounterst1[<shelf/slot/port>|<shelf/slot/port:chan>]
clearcounterst3<shelf/slot/port>
clearcounterstengigabitethernet<shelf/slot/port>
clearcountersvdsl<shelf/slot/port>
clearethernetcfmmepremoteassociationWORD
clearethernetcfmmepremotedomainWORD
clearethernetcfmmepremotedown
clearethernetcfmmepremoteinterfaceefmgroup<shelf/slot/group>
clearethernetcfmmepremoteinterfaceethernet<shelf/slot/port>
clearethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/port>
clearethernetcfmmepremotelevel<07>
clearethernetcfmmepremotelocalmep<18191>
clearethernetcfmmepremoteremotemep<18191>
clearethernetcfmmepremotevlan[<14094>|none]
clearipfileserverdownloadcache
clearmacaddresstable<shelf/slot>[authenticated|dynamic|multicast|static]
clearmacaddresstable<shelf/slot>addressxx:xx:xx:xx:xx:xx
clearmacaddresstableinterfaceethernet<shelf/slot/port>
clearmacaddresstableinterfacegigabitethernet<shelf/slot/port>
clearnodeinformation<1n>
clearperformancestatistics[adsl|backplane|e1|efmgroup|efm
link|erps|ethernet|evc|evcmap|framerelay|gigabit
ethernet|gpon|hdsl2|hdsl4|muxponderhighspeed|muxpondermidspeed|policer|ppp
group|ppplink|pseudowire|shdsl|t1|t3|tengigabitethernet|vdsl]
clearperformancestatisticsadsl<shelf/slot/port>

6TANV57CLI-35A

2-3

Total Access/NetVanta Carrier CLI Dictionary

clearperformancestatisticsbackplane<shelf/slot/port>
clearperformancestatisticse1<shelf/slot/port>
clearperformancestatisticsefmgroup<shelf/slot/group>
clearperformancestatisticsefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]
clearperformancestatisticserps<shelf/slot/ring>
clearperformancestatisticsethernet<shelf/slot/port>
clearperformancestatisticsevcWORD
clearperformancestatisticsevcWORD<shelf/slot>
clearperformancestatisticsevcmapWORD<shelf/slot>
clearperformancestatisticsframerelay[<shelf/slot/group>|dlci]
clearperformancestatisticsframerelay<shelf/slot/group>dlci
clearperformancestatisticsframerelay<shelf/slot/group>dlci<16991>
clearperformancestatisticsgigabitethernet<shelf/slot/port>
clearperformancestatisticsgpon<shelf/slot/port>
clearperformancestatisticshdsl2<shelf/slot/port>
clearperformancestatisticshdsl4<shelf/slot/port>
clearperformancestatisticsmuxponderhighspeed<shelf/slot/port>
clearperformancestatisticsmuxpondermidspeed<shelf/slot/port>
clearperformancestatisticspolicerWORD
clearperformancestatisticspppgroup<shelf/slot/group>
clearperformancestatisticsppplink[<shelf/slot/port>|<shelf/slot/port:chan>]
clearperformancestatisticspseudowire[<shelf/slot>|<shelf/slot/pwe>]
clearperformancestatisticsshdsl<shelf/slot/port>
clearperformancestatisticst1[<shelf/slot/port>|<shelf/slot/port:chan>]
clearperformancestatisticst3<shelf/slot/port>
clearperformancestatisticstengigabitethernet<shelf/slot/port>
clearperformancestatisticsvdsl<shelf/slot/port>
clearprocessescpumax
clearprocessescpumax<shelf/slot>
clearsecurityaccountageall
clearsecurityaccountageusernameWORD
clearsecuritypasswordageall
clearsecuritypasswordageusernameWORD
clearsplicedetect[hdsl2|hdsl4|shdsl]
clearsplicedetecthdsl2<shelf/slot/port>
clearsplicedetecthdsl4<shelf/slot/port>
clearsplicedetectshdsl<shelf/slot/port>
configureterminal
copyWORD[WORD|runningconfig|startupconfig]

2-4

6TANV57CLI-35A

Section 2, Commands - Common Commands

copyfileserverflash
copyfileserverflash[<shelf/slot>|<remoteindex>]
copyfileserverflash[<shelf/slot>|<remoteindex>]WORD
copyflash[ftp|tftp]
copyftp[flash|runningconfig|sca|startupconfig]
copyrunningconfig[WORD|ftp|startupconfig|tftp]
copysca[ftp|tftp]
copystartupconfig[WORD|ftp|runningconfig|tftp]
copytftp[flash|runningconfig|sca|startupconfig]
copyxmodem[flash|runningconfig|startupconfig]
copyymodem[flash|runningconfig|startupconfig]
copyymodemflash<shelf/slot>
disable
enable
erase[WORD|startupconfig]
erasestartupconfig<shelf/slot>
exit
forcealarm[acknowledge|clear|reset|resync]
forcealarmacknowledge<shelf/slot>
forcealarmclear<shelf/slot>
forcealarmreset<shelf/slot>
forcealarmresync<shelf/slot>
forceautoupgrade[abort|resetconfigcache|start]
forceexport[diagnostics|systemeventlog]
forceexportdiagnostics<shelf/slot/port>
forceexportsystemeventlognewevents
forceexportsystemeventlogtosyslog
forcelogoff<1n>
forcemanualswitcherpseast<shelf/slot/id>
forcemanualswitcherpswest<shelf/slot/id>
forcemanualswitchprotectiongroup<shelf/slot>
forcemanualswitchredundancy<shelf/slot>
forcemanualswitchsystemtiming<shelf>
forcepeerdefaultipdhcpclientreleaseinterfacepppgroup<shelf/slot/group>
forcepeerdefaultipdhcpclientrenewinterfacepppgroup<shelf/slot/group>
forceremotedownload<remoteindex>[application|boot]
forcerestartezprovisioning
forceretrain[fast|full]
forceretrainfast[<shelf/slot/port>|<shelf/slot>]

6TANV57CLI-35A

2-5

Total Access/NetVanta Carrier CLI Dictionary

forceretrainfull[<shelf/slot/port>|<shelf/slot>]
forcescr[all|modules]
forcesipregistration
forcesipregistration<shelf/slot>
forcesipregistration<shelf/slot><Txx>
forcesipregistration<shelf/slot><Txx>WORD
forcesshkeys
logout
pingA.B.C.D
pingA.B.C.Drepeat<11000000>
pingA.B.C.Drepeat<11000000>timeout<10008000>
pingA.B.C.Drepeat<11000000>timeout<10008000>size<01448>
pingatm<shelf/slot/port.sub>
pingatm<shelf/slot/port.sub>count<11000000>
pingatm<shelf/slot/port.sub>count<11000000>destinationllidHEX:32sourcellid
HEX:32
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORD
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligible
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligiblevalidatedata
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligiblevalidatedataverbose
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligibleverbose
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORD
validatedata

2-6

6TANV57CLI-35A

Section 2, Commands - Common Commands

pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORD
validatedataverbose
pingethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORD
verbose
pingiphostWORD<shelf/slot>A.B.C.D
pingiphostWORD<shelf/slot>A.B.C.Drepeat<11000000>
pingiphostWORD<shelf/slot>A.B.C.Drepeat<11000000>timeout<10005000>
pingiphostWORD<shelf/slot>A.B.C.Drepeat<11000000>timeout<10005000>size<0
1448>
promptdetail
reload
reload[<shelf/slot>|<remoteindex>]
show[aaa|alarm|arp|clock|defaultconfig|door|dynamiccounter|evc|evcmap|event
log|ezprovisioning|flash|interfaces|mevc|outputerrors|policer|protection
group|runningconfig|shaper|shdsl|sntp|startupconfig|system|systemmanagement
evc|systemtiming|temperaturesensor|users|version|vlan]
showaaa[local|radius|tacacs+]
showalarmlog[<shelf/slot>|ascending|descending]
showalarmlog<shelf/slot>[ascending|descending]
showarp<shelf/slot>
showautoupgrademodulestatus<shelf/slot>
showautoupgrademodulestatus<shelf/slot>realtime
showautoupgradeshelfstatus[<shelf>|realtime]
showautoupgradeshelfstatus<shelf>realtime
showclockdetail
showcopyfileserverflash[<shelf/slot>|<remoteindex>]
showcopyfileserverflash[<shelf/slot>|<remoteindex>]realtime
showdynamiccounter<shelf/slot/index>
showefmgroup[<shelf/slot>|<shelf>]
showefmlink[<shelf/slot>|<shelf>]
showethernetcfm[association|configerrors|defaultdomain|domain|stack|traceroute
cache]
showethernetcfmassociation[WORD|detail|incomplete]
showethernetcfmassociationWORD[WORD|detail]
showethernetcfmassociationWORDWORDdetail
showethernetcfmconfigerrorsinterfaceefmgroup<shelf/slot/group>
showethernetcfmconfigerrorsinterfaceethernet<shelf/slot/port>
showethernetcfmconfigerrorsinterfacegigabitethernet<shelf/slot/port>
showethernetcfmconfigerrorsvlan[<14094>|none]

6TANV57CLI-35A

2-7

Total Access/NetVanta Carrier CLI Dictionary

showethernetcfmdefaultdomaincomponentid<1n>
showethernetcfmdefaultdomaincomponentid<1n>vlan<14094>
showethernetcfmdefaultdomainvlan<14094>
showethernetcfmdomain[WORD|detail|incomplete]
showethernetcfmdomainWORDdetail
showethernetcfmmep[local|remote]
showethernetcfmmeplocal[detail|down|fault|statistics|up]
showethernetcfmmeplocalassociationWORD[detail|fault|statistics]
showethernetcfmmeplocaldomainWORD[detail|fault|statistics]
showethernetcfmmeplocaldown[detail|fault|statistics]
showethernetcfmmeplocalinterfaceefmgroup[<shelf/slot/port>|WORD]
showethernetcfmmeplocalinterfaceefmgroup[<shelf/slot/port>|WORD]detail
showethernetcfmmeplocalinterfaceefmgroup[<shelf/slot/port>|WORD]fault
showethernetcfmmeplocalinterfaceefmgroup[<shelf/slot/port>|WORD]statistics
showethernetcfmmeplocalinterfaceethernet<shelf/slot/port>[detail|fault|statistics]
showethernetcfmmeplocalinterfacegigabitethernet<shelf/slot/port>
[detail|fault|statistics]
showethernetcfmmeplocalinterfacepppgroup<shelf/slot/group>
[detail|fault|statistics]
showethernetcfmmeplocallevel<07>[detail|fault|statistics]
showethernetcfmmeplocalmepid<18191>[detail|fault|statistics]
showethernetcfmmeplocalup[detail|fault|statistics]
showethernetcfmmeplocalvlan[<14094>|none]
showethernetcfmmeplocalvlan<14094>[detail|fault|statistics]
showethernetcfmmeplocalvlannone[detail|fault|statistics]
showethernetcfmmepremote[detail|down]
showethernetcfmmepremoteassociationWORD
showethernetcfmmepremoteassociationWORDdetail
showethernetcfmmepremotedomainWORD
showethernetcfmmepremotedomainWORDdetail
showethernetcfmmepremotedowndetail
showethernetcfmmepremoteinterfaceefmgroup[<shelf/slot/port>|WORD]
showethernetcfmmepremoteinterfaceefmgroup[<shelf/slot/port>|WORD]detail
showethernetcfmmepremoteinterfaceethernet<shelf/slot/port>
showethernetcfmmepremoteinterfaceethernet<shelf/slot/port>detail
showethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/port>
showethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/port>detail
showethernetcfmmepremoteinterfacepppgroup<shelf/slot/group>
showethernetcfmmepremoteinterfacepppgroup<shelf/slot/group>detail

2-8

6TANV57CLI-35A

Section 2, Commands - Common Commands

showethernetcfmmepremotelevel<07>
showethernetcfmmepremotelevel<07>detail
showethernetcfmmepremotelocalmep<18191>
showethernetcfmmepremotelocalmep<18191>detail
showethernetcfmmepremoteremotemep<18191>
showethernetcfmmepremoteremotemep<18191>detail
showethernetcfmmepremotevlan[<14094>|none]
showethernetcfmmepremotevlan<14094>detail
showethernetcfmmepremotevlannonedetail
showethernetcfmstackdown
showethernetcfmstackinterfaceefmgroup<shelf/slot/group>
showethernetcfmstackinterfaceethernet<shelf/slot/port>
showethernetcfmstackinterfacegigabitethernet<shelf/slot/port>
showethernetcfmstackinterfacepppgroup<shelf/slot/group>
showethernetcfmstacklevel<07>
showethernetcfmstackvlan[<14094>|none]
showethernetcfmtraceroutecacheassociationWORD
showethernetcfmtraceroutecachedomainWORD
showethernetcfmtraceroutecacheinterfaceefmgroup[<shelf/slot/group>|WORD]
showethernetcfmtraceroutecacheinterfaceethernet<shelf/slot/port>
showethernetcfmtraceroutecacheinterfacegigabitethernet<shelf/slot/port>
showethernetcfmtraceroutecachelevel<07>
showethernetcfmtraceroutecachelocalmepid<18191>
showethernetcfmtraceroutecachevlan[<14094>|none]
showethernetevcadvertisement
showethernetevcadvertisementinterface[efmgroup|ethernet|gigabit
ethernet|muxponderhighspeed|muxpondermidspeed]
showethernetevcadvertisementinterfaceefmgroup<shelf/slot/group>
showethernetevcadvertisementinterfaceethernet<shelf/slot/port>
showethernetevcadvertisementinterfacegigabitethernet<shelf/slot/port>
showethernetevcadvertisementinterfacemuxponderhighspeed<shelf/slot/port>
showethernetevcadvertisementinterfacemuxpondermidspeed<shelf/slot/port>
showevcWORD
showevcmapWORD
showevcmapWORD<shelf/slot>
showeventhistory<shelf/slot>
showeventlogdetail<1n>
showeventlogstatistics
showeventlogtype[account|date|login|module|network|sca|security|snmp|upgrade]

6TANV57CLI-35A

2-9

Total Access/NetVanta Carrier CLI Dictionary

showeventlogtypeaccountdetail<1n>
showeventlogtypedatedetail<1n>
showeventlogtypelogindetail<1n>
showeventlogtypemoduledetail<1n>
showeventlogtypenetworkdetail<1n>
showeventlogtypescadetail<1n>
showeventlogtypesecuritydetail<1n>
showeventlogtypesnmpdetail<1n>
showeventlogtypeupgradedetail<1n>
showfan<shelf>
showfileWORD
showinterfaces[adsl|atm|backplane|e1|efmgroup|efmlink|efm
port|erps|ethernet|framerelay|fxs|gigabitethernet|gpon|hdsl2|hdsl4|lag
group|muxponderhighspeed|muxpondermidspeed|packettiming|pppgroup|ppp
link|processorethernet|pseudowire|rfvideo|shdsl|t1|t3|tengigabitethernet|vdsl]
showinterfacesadsl<shelf/slot/port>bitallocationtable[downstream|upstream]
showinterfacesadsl<shelf/slot/port>circuit[capabilities|inventory]
showinterfacesadsl<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesadsl<shelf/slot/port>performancestatistics15minute[<196>|realtime]
showinterfacesadsl<shelf/slot/port>performancestatistics24hour[<17>|realtime]
showinterfacesadsl<shelf/slot/port>realtime
showinterfacesadsl<shelf/slot/port>snrtableupstream
showinterfacesatm<shelf/slot/port>
showinterfacesatm<shelf/slot/port>realtime
showinterfacesatmgroup<shelf/slot/group>legacyatm
showinterfacesatmgrouplegacyatm
showinterfacesbackplane<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesbackplane<shelf/slot/port>performancestatistics15minute<196>
showinterfacesbackplane<shelf/slot/port>performancestatistics24hour<17>
showinterfacesbackplane<shelf/slot/port>realtime
showinterfacese1<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacese1<shelf/slot/port>performancestatistics15minute<196>
showinterfacese1<shelf/slot/port>performancestatistics24hour<17>
showinterfacese1<shelf/slot/port>realtime
showinterfacesefmgroup[<shelf/slot/group>|WORD]
showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics15minute
showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics15minute
<196>
showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics15minute
realtime

2-10

6TANV57CLI-35A

Section 2, Commands - Common Commands

showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics24hour
showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics24hour<1
7>
showinterfacesefmgroup[<shelf/slot/group>|WORD]performancestatistics24hour
realtime
showinterfacesefmgroup[<shelf/slot/group>|WORD]realtime
showinterfacesefmgroup[<shelf/slot/group>|WORD]subtendedhost
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minute
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minute<196>
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minuterealtime
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hour
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hour<17>
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hourrealtime
showinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]realtime
showinterfacesefmport<shelf/slot/port>
showinterfacesefmport<shelf/slot/port>realtime
showinterfaceserps<shelf/slot/ring>[performancestatistics|realtime]
showinterfaceserps<shelf/slot/ring>performancestatistics[15minute|24hour]
showinterfaceserps<shelf/slot/ring>performancestatistics15minute<096>
showinterfaceserps<shelf/slot/ring>performancestatistics24hour<07>
showinterfacesethernet<shelf/slot/port>[realtime|subtendedhost]
showinterfacesethernet<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesethernet<shelf/slot/port>performancestatistics15minute<196>
showinterfacesethernet<shelf/slot/port>performancestatistics24hour<17>
showinterfacesframerelay[<shelf/slot/group>|dlci]
showinterfacesframerelay<shelf/slot/group>dlci
showinterfacesframerelay<shelf/slot/group>dlci<16991>performancestatistics[15
minutes|24hour]
showinterfacesframerelay<shelf/slot/group>dlci<16991>performancestatistics15
minutes[<196>|realtime]
showinterfacesframerelay<shelf/slot/group>dlci<16991>performancestatistics24
hour[<17>|realtime]
showinterfacesframerelay<shelf/slot/group>dlci<16991>realtime
showinterfacesframerelay<shelf/slot/group>performancestatistics[15minutes|24
hour]

6TANV57CLI-35A

2-11

Total Access/NetVanta Carrier CLI Dictionary

showinterfacesframerelay<shelf/slot/group>performancestatistics15minutes[<1
96>|realtime]
showinterfacesframerelay<shelf/slot/group>performancestatistics24hour[<1
7>|realtime]
showinterfacesframerelay<shelf/slot/group>realtime
showinterfacesfxs[<shelf/slot/port>|<remoteindex>]
showinterfacesfxs[<shelf/slot/port>|<remoteindex>]linetest
showinterfacesfxs[<shelf/slot/port>|<remoteindex>]realtime
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]performancestatistics
15minute
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]performancestatistics
15minute<196>
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]performancestatistics
24hour
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]performancestatistics
24hour<17>
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]pluggable
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]realtime
showinterfacesgigabitethernet[<shelf/slot/port>|<remoteindex>]subtendedhost
showinterfacesgpon<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesgpon<shelf/slot/port>performancestatistics15minute<196>
showinterfacesgpon<shelf/slot/port>performancestatistics24hour<17>
showinterfacesgpon<shelf/slot/port>subtendedhost
showinterfaceshdsl2<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfaceshdsl2<shelf/slot/port>performancestatistics15minute<196>
showinterfaceshdsl2<shelf/slot/port>performancestatistics24hour<17>
showinterfaceshdsl2<shelf/slot/port>splicedetect[24hour|histogram]
showinterfaceshdsl2<shelf/slot/port>splicedetect24hour<114>
showinterfaceshdsl4<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfaceshdsl4<shelf/slot/port>performancestatistics15minute<196>
showinterfaceshdsl4<shelf/slot/port>performancestatistics24hour<17>
showinterfaceshdsl4<shelf/slot/port>splicedetect[24hour|histogram]
showinterfaceshdsl4<shelf/slot/port>splicedetect24hour<114>
showinterfacesiphostWORD[<shelf/slot>|<remoteindex>]
showinterfacesiphostslot<shelf/slot>
showinterfaceslaggroup<shelf/slot/group>
showinterfaceslaggroup<shelf/slot/group>realtime
showinterfacesmuxponderhighspeed{<shelf/slot/port>}
showinterfacesmuxponderhighspeed<shelf/slot/port>performancestatistics[15
minute|24hour]

2-12

6TANV57CLI-35A

Section 2, Commands - Common Commands

showinterfacesmuxponderhighspeed<shelf/slot/port>performancestatistics15minute
<196>
showinterfacesmuxponderhighspeed<shelf/slot/port>performancestatistics24hour
<17>
showinterfacesmuxponderhighspeed<shelf/slot/port>pluggable
showinterfacesmuxponderhighspeed<shelf/slot/port>realtime
showinterfacesmuxponderhighspeed<shelf/slot/port>subtendedhost
showinterfacesmuxpondermidspeed{<shelf/slot/port>}
showinterfacesmuxpondermidspeed<shelf/slot/port>performancestatistics[15
minute|24hour]
showinterfacesmuxpondermidspeed<shelf/slot/port>performancestatistics15minute
<196>
showinterfacesmuxpondermidspeed<shelf/slot/port>performancestatistics24hour<1
7>
showinterfacesmuxpondermidspeed<shelf/slot/port>pluggable
showinterfacesmuxpondermidspeed<shelf/slot/port>realtime
showinterfacesmuxpondermidspeed<shelf/slot/port>subtendedhost
showinterfacespackettiming<shelf/slot>
showinterfacespppgroup<shelf/slot/group>performancestatistics[15minute|24hour]
showinterfacespppgroup<shelf/slot/group>performancestatistics15minute[<1
96>|realtime]
showinterfacespppgroup<shelf/slot/group>performancestatistics24hour[<1
7>|realtime]
showinterfacespppgroup<shelf/slot/group>realtime
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minute
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minute<196>
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minuterealtime
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hour
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hour<17>
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hourrealtime
showinterfacesppplink[<shelf/slot/port>|<shelf/slot/port:chan>]realtime
showinterfacespseudowire[<shelf/slot>|<shelf/slot/pwe>|<remoteindex>]
showinterfacespseudowire[<shelf/slot>|<shelf/slot/pwe>|<remoteindex>]performance
statistics15minute
showinterfacespseudowire[<shelf/slot>|<shelf/slot/pwe>|<remoteindex>]performance
statistics15minute<196>

6TANV57CLI-35A

2-13

Total Access/NetVanta Carrier CLI Dictionary

showinterfacespseudowire[<shelf/slot>|<shelf/slot/pwe>|<remoteindex>]performance
statistics24hour
showinterfacespseudowire[<shelf/slot>|<shelf/slot/pwe>|<remoteindex>]performance
statistics24hour<17>
showinterfacesrfvideo<remoteindex>
showinterfacesshdsl<shelf/slot/port>[circuit|realtime]
showinterfacesshdsl<shelf/slot/port>circuitinventory
showinterfacesshdsl<shelf/slot/port>circuitperformancestatistics[15minute|24hour]
showinterfacesshdsl<shelf/slot/port>circuitperformancestatistics15minute<196>
showinterfacesshdsl<shelf/slot/port>circuitperformancestatistics24hour<17>
showinterfacesshdsl<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesshdsl<shelf/slot/port>performancestatistics15minute<196>
showinterfacesshdsl<shelf/slot/port>performancestatistics24hour<17>
showinterfacesshdsl<shelf/slot/port>splicedetect24hour
showinterfacesshdsl<shelf/slot/port>splicedetect24hour<17>
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics15
minute
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics15
minute<196>
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics24hour
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics24hour
<17>
showinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]realtime
showinterfacest3<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacest3<shelf/slot/port>performancestatistics15minute<196>
showinterfacest3<shelf/slot/port>performancestatistics24hour<17>
showinterfacest3<shelf/slot/port>realtime
showinterfacestengigabitethernet<shelf/slot/port>[pluggable|realtime]
showinterfacestengigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showinterfacestengigabitethernet<shelf/slot/port>performancestatistics15minute<1
96>
showinterfacestengigabitethernet<shelf/slot/port>performancestatistics24hour<17>
showinterfacesvdsl<shelf/slot/port>bandtable[downstream|upstream]
showinterfacesvdsl<shelf/slot/port>bitallocationtable[downstream|upstream]
showinterfacesvdsl<shelf/slot/port>performancestatistics[15minute|24hour]
showinterfacesvdsl<shelf/slot/port>performancestatistics15minute[<196>|realtime]
showinterfacesvdsl<shelf/slot/port>performancestatistics15minute<196>realtime
showinterfacesvdsl<shelf/slot/port>performancestatistics24hour[<17>|realtime]
showinterfacesvdsl<shelf/slot/port>performancestatistics24hour<17>realtime

2-14

6TANV57CLI-35A

Section 2, Commands - Common Commands

showinterfacesvdsl<shelf/slot/port>realtime
showinterfacesvdsl<shelf/slot/port>snrtableupstream
showip[accesslists|ntp|route]
showipaccesslistsWORD
showipigmp[evc|evcmap|groups|interface]
showipigmpevcWORD<shelf/slot>performancestatistics[15minute|24hour]
showipigmpevcWORD<shelf/slot>performancestatistics15minute<196>
showipigmpevcWORD<shelf/slot>performancestatistics24hour<17>
showipigmpevcWORD<shelf/slot>realtime
showipigmpevcWORDperformancestatistics[15minute|24hour]
showipigmpevcWORDperformancestatistics15minute<196>
showipigmpevcWORDperformancestatistics24hour<17>
showipigmpevcmapWORD<shelf/slot>performancestatistics[15minute|24hour]
showipigmpevcmapWORD<shelf/slot>performancestatistics15minute<196>
showipigmpevcmapWORD<shelf/slot>performancestatistics24hour<17>
showipigmpevcmapWORD<shelf/slot>realtime
showipigmpgroups<shelf/slot>
showipigmpgroups<shelf/slot>A.B.C.D
showipigmpinterface[adsl|backplane|gigabitethernet|tengigabitethernet|vdsl]
showipigmpinterfaceadsl<shelf/slot/port>performancestatistics[15minute|24hour]
showipigmpinterfaceadsl<shelf/slot/port>performancestatistics15minute<196>
showipigmpinterfaceadsl<shelf/slot/port>performancestatistics24hour<196>
showipigmpinterfaceadsl<shelf/slot/port>realtime
showipigmpinterfacebackplane<shelf/slot/port>performancestatistics[15minute|24
hour]
showipigmpinterfacebackplane<shelf/slot/port>performancestatistics15minute<1
96>
showipigmpinterfacebackplane<shelf/slot/port>performancestatistics24hour<17>
showipigmpinterfacebackplane<shelf/slot/port>realtime
showipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics15minute
<196>
showipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics24hour
<17>
showipigmpinterfacegigabitethernet<shelf/slot/port>realtime
showipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics15
minute<196>

6TANV57CLI-35A

2-15

Total Access/NetVanta Carrier CLI Dictionary

showipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics24
hour<17>
showipigmpinterfacetengigabitethernet<shelf/slot/port>realtime
showipigmpinterfacevdsl<shelf/slot/port>performancestatistics[15minute|24hour]
showipigmpinterfacevdsl<shelf/slot/port>performancestatistics15minute<196>
showipigmpinterfacevdsl<shelf/slot/port>performancestatistics24hour<17>
showipigmpinterfacevdsl<shelf/slot/port>realtime
showipntpassociations
showlacp[<shelf/slot>|systemid]
showlacp<shelf/slot>[counters|states|summary]
showlacpinterfacegigabitethernet<shelf/slot/port>[states|summary]
showlacpinterfacelaggroup<shelf/slot/group>[states|summary]
showlacpinterfacetengigabitethernet<shelf/slot/port>[states|summary]
showlineconsole<0>
showmac[addresstable|limits]
showmacaddresstable<shelf/slot>[agingtime|count|dynamic|multicast|static]
showmacaddresstable<shelf/slot>dynamicstag<14094>
showmacaddresstable<shelf/slot>evcWORD
showmacaddresstable<shelf/slot>stag<14094>
showmacaddresstable<shelf/slot>staticstag<14094>
showmacaddresstabledynamicinterfacebackplane<shelf/slot/port>
showmacaddresstabledynamicinterfacegigabitethernet<shelf/slot/port>
showmacaddresstabledynamicinterfacemuxponderhighspeed<shelf/slot/port>
showmacaddresstabledynamicinterfacemuxpondermidspeed<shelf/slot/port>
showmacaddresstabledynamicinterfacetengigabitethernet<shelf/slot/port>
showmacaddresstableinterfacebackplane<shelf/slot/port>
showmacaddresstableinterfacegigabitethernet<shelf/slot/port>
showmacaddresstableinterfacemuxponderhighspeed<shelf/slot/port>
showmacaddresstableinterfacemuxpondermidspeed<shelf/slot/port>
showmacaddresstableinterfacetengigabitethernet<shelf/slot/port>
showmacaddresstablestaticinterfacebackplane<shelf/slot/port>
showmacaddresstablestaticinterfacegigabitethernet<shelf/slot/port>
showmacaddresstablestaticinterfacemuxponderhighspeed<shelf/slot/port>
showmacaddresstablestaticinterfacemuxpondermidspeed<shelf/slot/port>
showmacaddresstablestaticinterfacetengigabitethernet<shelf/slot/port>
showmenu[configuration|status]
showmenuperformancestatisticse1<shelf/slot/port>[15minute|24hour]
showmenuperformancestatisticsethernet<shelf/slot/port>[15minute|24hour]
showmenuperformancestatisticsgigabitethernet<shelf/slot/port>[15minute|24hour]

2-16

6TANV57CLI-35A

Section 2, Commands - Common Commands

showmenuperformancestatisticshdsl2<shelf/slot/port>[15minute|24hour]
showmenuperformancestatisticshdsl4<shelf/slot/port>[15minute|24hour]
showmenuperformancestatisticsshdsl<shelf/slot/port>[15minute|24hour]
showmenuperformancestatisticst1[<shelf/slot/port>|<shelf/slot/port:chan>]15minute
showmenuperformancestatisticst1[<shelf/slot/port>|<shelf/slot/port:chan>]24hour
showmenuperformancestatisticst3<shelf/slot/port>[15minute|24hour]
showmenuprovisioninge1<shelf/slot/port>
showmenuprovisioningethernet<shelf/slot/port>
showmenuprovisioninggigabitethernet<shelf/slot/port>
showmenuprovisioninghdsl2<shelf/slot/port>
showmenuprovisioninghdsl4<shelf/slot/port>
showmenuprovisioningshdsl<shelf/slot/port>
showmenuprovisioningt1<shelf/slot/port>
showmenuprovisioningt3<shelf/slot/port>
showmenustatusdetail
showmevcWORD
showmevcWORD<shelf/slot>
showmuxponderethernet<shelf/slot>qos[cosmap|untagged]
shownodeinformationstatistics
showpeerdefaultipdhcpclientleaseinterfacepppgroup<shelf/slot/group>
showpolicerWORD<shelf/slot>
showpolicerWORDperformancestatistics[15minute|24hour]
showpolicerWORDperformancestatistics15minute<196>
showpolicerWORDperformancestatistics24hour<17>
showportauthinterfaceatm<shelf/slot/port>
showportauthinterfaceefmport<shelf/slot/port>
showportauthstatisticsinterfaceatm<shelf/slot/port>
showportauthstatisticsinterfaceefmport<shelf/slot/port>
showpppgroup[<shelf/slot>|<shelf>]
showppplink[<shelf/slot>|<shelf>]
showproberespondertwamp
showproberespondertwampverbose
showprocessessummary
showprocessessummary<shelf/slot>
showprotectiongroup[<shelf/group>|WORD]
showqos[cosmap|untagged]
showqueueinterfaces[efmgroup|ethernet|gigabitethernet|muxponder
highspeed|muxpondermidspeed|tengigabitethernet]
showqueueinterfacesefmgroup<shelf/slot/group>

6TANV57CLI-35A

2-17

Total Access/NetVanta Carrier CLI Dictionary

showqueueinterfacesefmgroup<shelf/slot/group><0n>
showqueueinterfacesethernet<shelf/slot/port>
showqueueinterfacesethernet<shelf/slot/port><0n>
showqueueinterfacesgigabitethernet<shelf/slot/port>
showqueueinterfacesgigabitethernet<shelf/slot/port><0n>
showqueueinterfacesmuxponderhighspeed<shelf/slot/port>
showqueueinterfacesmuxponderhighspeed<shelf/slot/port><0n>
showqueueinterfacesmuxpondermidspeed<shelf/slot/port>
showqueueinterfacesmuxpondermidspeed<shelf/slot/port><0n>
showqueueinterfacestengigabitethernet<shelf/slot/port>
showqueueinterfacestengigabitethernet<shelf/slot/port><0n>
showredundancy<shelf/slot>
showremotedevices<remoteindex>
showringgenerator<shelf>
showrunningconfig[arp|autoupgrade|counterprofile|dynamiccounter|evc|evc
map|eventlogexport|fan|mevc|muxponderethernet|policer|power
shedding|protection
group|queue|redundancy|sca|security|shaper|slot|system|systemalarm|system
managementevc|systemtiming|temperaturesensor|tl1|verbose]
showrunningconfigarp[<shelf/slot>|verbose]
showrunningconfigarp<shelf/slot>verbose
showrunningconfigautoupgradeverbose
showrunningconfigcounterprofile[<shelf/slot>|verbose]
showrunningconfigcounterprofile<shelf/slot>verbose
showrunningconfigdynamiccounter[<shelf/slot>|verbose]
showrunningconfigdynamiccounter<shelf/slot>verbose
showrunningconfigethernetcfm
showrunningconfigethernetcfmverbose
showrunningconfigevc[WORD|verbose]
showrunningconfigevcWORDverbose
showrunningconfigevcmap[WORD|verbose]
showrunningconfigevcmapWORD[<shelf/slot>|verbose]
showrunningconfigevcmapWORD<shelf/slot>verbose
showrunningconfigeventlogexportverbose
showrunningconfigfan[<shelf/slot>|verbose]
showrunningconfigfan<shelf/slot>verbose
showrunningconfiginterface[adsl|atm|e1|efmgroup|efmlink|efm
port|erps|ethernet|framerelay|fxs|gigabitethernet|gpon|hdsl2|hdsl4|iphost|lag
group|muxponderhighspeed|muxpondermidspeed|packettiming|pppgroup|rf
video|shdsl|t1|t3|tengigabitethernet|vdsl]
showrunningconfiginterfaceadsl[[<shelf/slot>|<shelf/slot/port>]|verbose]

2-18

6TANV57CLI-35A

Section 2, Commands - Common Commands

showrunningconfiginterfaceadsl[<shelf/slot>|<shelf/slot/port>]verbose
showrunningconfiginterfaceatm[<shelf/slot>|verbose]
showrunningconfiginterfaceatm<shelf/slot>verbose
showrunningconfiginterfaceatmgroup<shelf/slot/group>legacyatm
showrunningconfiginterfaceatmgroup<shelf/slot/group>legacyatmverbose
showrunningconfiginterfaceatmgrouplegacyatm
showrunningconfiginterfaceatmgrouplegacyatmverbose
showrunningconfiginterfacee1[<shelf/slot>|verbose]
showrunningconfiginterfacee1<shelf/slot>verbose
showrunningconfiginterfaceefmgroup[<shelf/slot>|verbose]
showrunningconfiginterfaceefmgroup<shelf/slot>verbose
showrunningconfiginterfaceefmlink[<shelf/slot>|verbose]
showrunningconfiginterfaceefmlink<shelf/slot>verbose
showrunningconfiginterfaceefmport[<shelf/slot>|verbose]
showrunningconfiginterfaceefmport<shelf/slot>verbose
showrunningconfiginterfaceerps[<shelf/slot/ring>|verbose]
showrunningconfiginterfaceerps<shelf/slot/ring>verbose
showrunningconfiginterfaceethernet[<shelf/slot>|verbose]
showrunningconfiginterfaceethernet<shelf/slot>verbose
showrunningconfiginterfaceframerelay[<shelf/slot/group>|dlci|verbose]
showrunningconfiginterfaceframerelay<shelf/slot/group>[dlci|verbose]
showrunningconfiginterfaceframerelay<shelf/slot/group>dlci<16991>
showrunningconfiginterfaceframerelay<shelf/slot/group>dlci<16991>verbose
showrunningconfiginterfaceframerelaydlciverbose
showrunningconfiginterfacefxs[[<shelf/slot/port>|<remoteindex>]|verbose]
showrunningconfiginterfacefxs[<shelf/slot/port>|<remoteindex>]verbose
showrunningconfiginterfacegigabitethernet[[<shelf/slot>|<shelf/slot/port>|<remote
index>]|verbose]
showrunningconfiginterfacegigabitethernet[<shelf/slot>|<shelf/slot/port>|<remote
index>]verbose
showrunningconfiginterfacegpon[<shelf/slot/port>|verbose]
showrunningconfiginterfacegpon<shelf/slot/port>verbose
showrunningconfiginterfacehdsl2[<shelf/slot>|verbose]
showrunningconfiginterfacehdsl2<shelf/slot>verbose
showrunningconfiginterfacehdsl4[<shelf/slot>|verbose]
showrunningconfiginterfacehdsl4<shelf/slot>verbose
showrunningconfiginterfaceiphostWORD[<shelf/slot>|<remoteindex>]
showrunningconfiginterfaceiphostWORD[<shelf/slot>|<remoteindex>]verbose
showrunningconfiginterfaceiphostverbose

6TANV57CLI-35A

2-19

Total Access/NetVanta Carrier CLI Dictionary

showrunningconfiginterfacelaggroup[<shelf/slot>|verbose]
showrunningconfiginterfacelaggroup<shelf/slot>verbose
showrunningconfiginterfacemuxponderhighspeed[[<shelf/slot>|<shelf/slot/
port>]|verbose]
showrunningconfiginterfacemuxponderhighspeed[<shelf/slot>|<shelf/slot/port>]
verbose
showrunningconfiginterfacemuxpondermidspeed[[<shelf/slot>|<shelf/slot/
port>]|verbose]
showrunningconfiginterfacemuxpondermidspeed[<shelf/slot>|<shelf/slot/port>]
verbose
showrunningconfiginterfacepackettiming[<shelf/slot>|verbose]
showrunningconfiginterfacepackettiming<shelf/slot>verbose
showrunningconfiginterfacepppgroup[<shelf/slot/group>|verbose]
showrunningconfiginterfacepppgroup<shelf/slot/group>verbose
showrunningconfiginterfacepseudowire[<shelf/slot>|<shelf/slot/pwe>|<remote
index>]cem
showrunningconfiginterfacepseudowire[<shelf/slot>|<shelf/slot/pwe>|<remote
index>]cemverbose
showrunningconfiginterfacepseudowirecem
showrunningconfiginterfacepseudowirecemverbose
showrunningconfiginterfacerfvideo[<remoteindex>|verbose]
showrunningconfiginterfacerfvideo<remoteindex>verbose
showrunningconfiginterfaceshdsl[<shelf/slot>|verbose]
showrunningconfiginterfaceshdsl<shelf/slot>verbose
showrunningconfiginterfacet1[<shelf/slot>|verbose]
showrunningconfiginterfacet1<shelf/slot>verbose
showrunningconfiginterfacet3[<shelf/slot>|verbose]
showrunningconfiginterfacet3<shelf/slot>verbose
showrunningconfiginterfacetengigabitethernet[[<shelf/slot>|<shelf/slot/
port>]|verbose]
showrunningconfiginterfacetengigabitethernet[<shelf/slot>|<shelf/slot/port>]verbose
showrunningconfiginterfacevdsl[[<shelf/slot>|<shelf/slot/port>]|verbose]
showrunningconfiginterfacevdsl[<shelf/slot>|<shelf/slot/port>]verbose
showrunningconfigipigmpevc[WORD|verbose]
showrunningconfigipigmpevcWORD[<shelf/slot>|verbose]
showrunningconfigipigmpevcWORD<shelf/slot>verbose
showrunningconfigmevc[WORD|verbose]
showrunningconfigmevcWORD[<shelf/slot>|verbose]
showrunningconfigmevcWORD<shelf/slot>verbose
showrunningconfigmuxponderethernet[<shelf/slot>|verbose]
showrunningconfigmuxponderethernet<shelf/slot>verbose

2-20

6TANV57CLI-35A

Section 2, Commands - Common Commands

showrunningconfigpolicer[WORD|verbose]
showrunningconfigpolicerWORD[<shelf/slot>|verbose]
showrunningconfigpolicerWORD<shelf/slot>verbose
showrunningconfigpowersheddingverbose
showrunningconfigproberespondertwamp
showrunningconfigproberespondertwampverbose
showrunningconfigprotectiongroup[<shelf/slot>|verbose]
showrunningconfigprotectiongroup<shelf/slot>verbose
showrunningconfigqueueinterface[efmgroup|ethernet|gigabitethernet|muxponder
highspeed|muxpondermidspeed|tengigabitethernet]
showrunningconfigqueueinterfaceefmgroup[<shelf/slot/group>|verbose]
showrunningconfigqueueinterfaceefmgroup<shelf/slot/group>verbose
showrunningconfigqueueinterfaceethernet[<shelf/slot/port>|verbose]
showrunningconfigqueueinterfaceethernet<shelf/slot/port>verbose
showrunningconfigqueueinterfacegigabitethernet[<shelf/slot/port>|verbose]
showrunningconfigqueueinterfacegigabitethernet<shelf/slot/port>verbose
showrunningconfigqueueinterfacemuxponderhighspeed[<shelf/slot/port>|verbose]
showrunningconfigqueueinterfacemuxponderhighspeed<shelf/slot/port>verbose
showrunningconfigqueueinterfacemuxpondermidspeed[<shelf/slot/port>|verbose]
showrunningconfigqueueinterfacemuxpondermidspeed<shelf/slot/port>verbose
showrunningconfigqueueinterfacetengigabitethernet[<shelf/slot/port>|verbose]
showrunningconfigqueueinterfacetengigabitethernet<shelf/slot/port>verbose
showrunningconfigqueueverbose
showrunningconfigredundancy[<shelf/slot>|verbose]
showrunningconfigredundancy<shelf/slot>verbose
showrunningconfigremotedeviceont[<remoteindex>|verbose]
showrunningconfigremotedeviceont<remoteindex>verbose
showrunningconfigscaverbose
showrunningconfigsecurityverbose
showrunningconfigshaper[WORD|verbose]
showrunningconfigshaperWORD[[<shelf/slot>|<remoteindex>]|verbose]
showrunningconfigshaperWORD[<shelf/slot>|<remoteindex>]verbose
showrunningconfigslotverbose
showrunningconfigsystemverbose
showrunningconfigsystemalarm[<shelf>|verbose]
showrunningconfigsystemalarm<shelf>verbose
showrunningconfigsystemmanagementevcverbose
showrunningconfigsystemtiming[<shelf>|verbose]
showrunningconfigsystemtiming<shelf>verbose

6TANV57CLI-35A

2-21

Total Access/NetVanta Carrier CLI Dictionary

showrunningconfigtemperaturesensor[<shelf/slot/sensor>|verbose]
showrunningconfigtemperaturesensor<shelf/slot/sensor>verbose
showrunningconfigtl1verbose
showrunningconfigvoice[classofservice|dialplan|siptrunk|spre|user]
showrunningconfigvoiceclassofservice[WORD|verbose]
showrunningconfigvoiceclassofserviceWORDverbose
showrunningconfigvoicedialplanverbose
showrunningconfigvoicesiptrunk[<Txx>|verbose]
showrunningconfigvoicesiptrunk<Txx>verbose
showrunningconfigvoicespreverbose
showrunningconfigvoiceuser[NUMBER:20|verbose]
showrunningconfigvoiceuserNUMBER:20verbose
showsca[autosavestatus|restorestatus|savestatus]
showscaautosavestatusrealtime
showscarestorestatusrealtime
showscasavestatusrealtime
showscrshelfstatus
showscrshelfstatusrealtime
showshaperWORD
showshaperWORD[<shelf/slot>|<remoteindex>]
showsntprealtime
showsystem[inventory|parameters]
showsystemtiming<shelf>
showsystemtiming<shelf>detail
showtable[evc|evcmap|mevc|nodeinformation|policer|shaper|systemtiming]
showtableevc[macswitched|tagswitched]
showtableevcmap<shelf/slot>
showtableevcmapevcWORD
showtableevcmapmevcWORD<shelf/slot>
showtableinterfaces[adsl|efmgroup|efmlink|framerelay|gpon|rfvideo|shdsl|vdsl]
showtableinterfacesadsl[<shelf/slot/port>|<shelf/slot>]
showtableinterfacesadsl[<shelf/slot/port>|<shelf/slot>]downstreamperformance
statistics15minute
showtableinterfacesadsl[<shelf/slot/port>|<shelf/slot>]downstreamperformance
statistics24hour
showtableinterfacesadsl[<shelf/slot/port>|<shelf/slot>]upstreamperformancestatistics
15minute
showtableinterfacesadsl[<shelf/slot/port>|<shelf/slot>]upstreamperformancestatistics
24hour
showtableinterfacesbackplane<shelf/slot/port>

2-22

6TANV57CLI-35A

Section 2, Commands - Common Commands

showtableinterfacesbackplane<shelf/slot/port>performancestatistics[15minute|24
hour]
showtableinterfacesefmgroup<shelf/slot/group>
showtableinterfacesefmgroup<shelf/slot/group>performancestatistics[15minute|24
hour]
showtableinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]
showtableinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performance
statistics15minute
showtableinterfacesefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]performance
statistics24hour
showtableinterfacesframerelay[[<shelf/slot/group>|<shelf/slot>]|dlci|realtime]
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>ip
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>ip
realtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics15minute
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics15minutecongestion
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics15minutecongestionrealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics15minuterealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics24hour
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics24hourcongestion
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics24hourcongestionrealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>
performancestatistics24hourrealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlci<16991>realtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlciip
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlciiprealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]dlcirealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
15minute
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
15minuterealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
15minutesignaling
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
15minutesignalingrealtime

6TANV57CLI-35A

2-23

Total Access/NetVanta Carrier CLI Dictionary

showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
24hour
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
24hourrealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
24hoursignaling
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]performancestatistics
24hoursignalingrealtime
showtableinterfacesframerelay[<shelf/slot/group>|<shelf/slot>]realtime
showtableinterfacesframerelaydlci[ip|realtime]
showtableinterfacesframerelaydlciiprealtime
showtableinterfacesgigabitethernet<shelf/slot/port>
showtableinterfacesgigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableinterfacesgpon[<shelf/slot/port>|<remoteindex>]
showtableinterfacesgpon[<shelf/slot/port>|<remoteindex>]performancestatistics15
minute
showtableinterfacesgpon[<shelf/slot/port>|<remoteindex>]performancestatistics24
hour
showtableinterfacesmuxponderhighspeed<shelf/slot/port>
showtableinterfacesmuxponderhighspeed<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableinterfacesmuxpondermidspeed<shelf/slot/port>
showtableinterfacesmuxpondermidspeed<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableinterfacesrfvideo<remoteindex>
showtableinterfacesshdsl<shelf/slot/port>
showtableinterfacesshdsl<shelf/slot/port>performancestatistics[15minute|24hour]
showtableinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
15minute
showtableinterfacest1[<shelf/slot/port>|<shelf/slot/port:chan>]performancestatistics
24hour
showtableinterfacest3<shelf/slot/port>performancestatistics[15minute|24hour]
showtableinterfacestengigabitethernet<shelf/slot/port>
showtableinterfacestengigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableinterfacesvdsl[<shelf/slot/port>|<shelf/slot>]
showtableinterfacesvdsl[<shelf/slot/port>|<shelf/slot>]downstreamperformance
statistics15minute
showtableinterfacesvdsl[<shelf/slot/port>|<shelf/slot>]downstreamperformance
statistics24hour
showtableinterfacesvdsl[<shelf/slot/port>|<shelf/slot>]upstreamperformancestatistics
15minute

2-24

6TANV57CLI-35A

Section 2, Commands - Common Commands

showtableinterfacesvdsl[<shelf/slot/port>|<shelf/slot>]upstreamperformancestatistics
24hour
showtableipigmpevcWORD<shelf/slot>
showtableipigmpevcWORD<shelf/slot>performancestatistics[15minute|24hour]
showtableipigmpevcWORDperformancestatistics[15minute|24hour]
showtableipigmpevcmapWORD<shelf/slot>
showtableipigmpevcmapWORD<shelf/slot>performancestatistics[15minute|24
hour]
showtableipigmpinterfaceadsl<shelf/slot/port>
showtableipigmpinterfaceadsl<shelf/slot/port>performancestatistics[15minute|24
hour]
showtableipigmpinterfacebackplane<shelf/slot/port>
showtableipigmpinterfacebackplane<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableipigmpinterfacegigabitethernet<shelf/slot/port>
showtableipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics[15
minute|24hour]
showtableipigmpinterfacetengigabitethernet<shelf/slot/port>
showtableipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics
[15minute|24hour]
showtableipigmpinterfacevdsl<shelf/slot/port>
showtableipigmpinterfacevdsl<shelf/slot/port>performancestatistics[15minute|24
hour]
showtablemevc<shelf/slot>[macswitched|tagswitched]
showtablepolicer<shelf/slot>
showtablequeueinterfaces[efmgroup|ethernet|gigabitethernet|muxponder
highspeed|muxpondermidspeed|tengigabitethernet]
showtablequeueinterfacesefmgroup<shelf/slot/group>
showtablequeueinterfacesethernet<shelf/slot/port>
showtablequeueinterfacesgigabitethernet<shelf/slot/port>
showtablequeueinterfacesmuxponderhighspeed<shelf/slot/port>
showtablequeueinterfacesmuxpondermidspeed<shelf/slot/port>
showtablequeueinterfacestengigabitethernet<shelf/slot/port>
showtableremotedevices[<remoteindex>|inactive]
showtableremotedevicesinactive<shelf/slot/port>
showtableshaper[<shelf/slot>|<remoteindex>]
showtablesipregistration
showtablesipregistration<shelf/slot>[<Txx>|realtime]
showtablesipregistration<shelf/slot><Txx>[WORD|realtime]
showtablesipregistration<shelf/slot><Txx>WORDrealtime
showtablesystemtiming<shelf>

6TANV57CLI-35A

2-25

Total Access/NetVanta Carrier CLI Dictionary

showtemperaturesensor<shelf/slot/sensor>
showtopologyinterfaceserps<shelf/slot/ring>
showtopologyinterfaceserps<shelf/slot/ring>detail
showtopologytree
showtopologytreedetail
showtopologytreedetail<164>
showusers[loginstats|realtime]
showusersloginstatslocal
showversion[<shelf/slot>|<remoteindex>]
showvlan<14094>
telnetA.B.C.D
telnetA.B.C.Dport<165535>
terminallength<0,2480>
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>sorted
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>ttl<1255>
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>ttl<1255>
fdbonly
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>ttl<1255>
fdbonlysorted
tracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]sourceWORDWORD<18191>ttl<1255>
sorted
write

2-26

6TANV57CLI-35A

Section 2, Commands - Common Commands

application
UsetheapplicationcommandtoactivatetheApplicationConfigurationCommandSet.Appli
cationsareaugmentationstotheuserinterfacethatareusedtosimplifytestingorconfiguring
anaspectofthesystem.

Usage Examples
Thefollowingisanexampleofhowtousetheapplicationcommand.
#application
(app)#

Functional Notes
ThepromptchangesasverificationthattheApplicationConfigurationCommandSetis
available.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM
(1188801G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
46777

6TANV57CLI-35A

2-27

Total Access/NetVanta Carrier CLI Dictionary

clear [arp|counters|node-information]
Usetheclearcommandtoresetthealarmlogfortheunitortoclearallinterfacecountersor
countersforaspecificinterface.

Syntax Description
arp

ClearARPCache

counters

Clearallcounters

nodeinformation

Clearallnodeinformation

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1),
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42811

2-28

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear arp <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
111653

6TANV57CLI-35A

2-29

Total Access/NetVanta Carrier CLI Dictionary

clear counters [aaa|adsl|backplane|dynamic-counter|e1|efmgroup|efm-link|efm-port|erps|ethernet|evc|evc-map|framerelay|fxs|gigabit-ethernet|hdsl2|hdsl4|lacp|muxponderhighspeed|muxponder-midspeed|packet-timing|policer|pppgroup|ppp-link|pseudowire|shdsl|t1|t3|ten-gigabitethernet|vdsl]


Usetheclearcounterscommandtoclearallinterfacecountersoronlythecountersfora
specifiedinterface.Thiscommanddoesnotclearperformancemonitoringstatistics.

Syntax Description

2-30

counters

Clearallcounters

aaa

ClearallAAAcounters

adsl

ClearcountersonallADSLinterfaces

backplane

ClearcountersonallBackplaneinterfaces

dynamiccounter

Clearalldynamiccounters

e1

ClearcountersonallE1interfaces

efmgroup

ClearcountersonallEFMGroups

efmlink

ClearcountersforallEFMlinks

efmport

ClearcountersforallEFMports

erps

ClearcountersonallERPSinterfaces

ethernet

ClearcountersonallEthernetinterfaces

evc

ClearcountersonallEVCsandslots

evcmap

ClearcountersonallEVCMapinterfaces

framerelay

ClearcountersforallFrameRelayGroups

fxs

ClearcountersforallFXSinterfaces

gigabitethernet

ClearcountersonallGigabitEthernetinterfaces

hdsl2

ClearcountersonallHDSL2interfaces

hdsl4

ClearcountersonallHDSL4interfaces

lacp

ClearLACPstatisticsonallgroups

muxponderhighspeed

ClearcountersonallMuxponderHighspeedinterfaces

muxpondermidspeed

ClearcountersonallMuxponderMidspeedinterfaces

packettiming

Clearcountersonallpackettiminginterfaces

6TANV57CLI-35A

Section 2, Commands - Common Commands

policer

Clearcountersonallpolicers

pppgroup

ClearcountersonallPPPGroups

ppplink

ClearcountersforallPPPlinks

pseudowire

ClearcountersonallPseudowireinterfaces

shdsl

ClearcountersonallSHDSLinterfaces

t1

ClearcountersonallT1interfaces

t3

ClearcountersonallT3interfaces

tengigabitethernet

ClearcountersonallTenGigabitEthernetinterfaces

vdsl

ClearcountersonallVDSLinterfaces

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounters[aaa|adsl|backplane|dynamic
counter|e1|efmgroup|efmlink|efmport|erps|ethernet|evc|evcmap|frame
relay|fxs|gigabitethernet|hdsl2|hdsl4|lacp|muxponderhighspeed|muxponder
midspeed|packettiming|policer|pppgroup|ppplink|pseudowire|shdsl|t1|t3|tengigabit
ethernet|vdsl]command.
#clear counters
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP

6TANV57CLI-35A

2-31

Total Access/NetVanta Carrier CLI Dictionary

(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42812

2-32

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters aaa [local|radius|tacacs+]


Usetheclearcountersaaa[local|radius|tacacs+]commandtoclearcountersforaspecified
AAAsubsystem.

Syntax Description
aaa

ClearallAAAcounters

local

ClearonlyLocalspecificAAAcounters

radius

ClearonlyRADIUSspecificAAAcounters

tacacs+

ClearonlyTACACS+specificAAAcounters

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersaaa[local|radius|tacacs+]
command.
#clear counters tacacs+
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77377

6TANV57CLI-35A

2-33

Total Access/NetVanta Carrier CLI Dictionary

clear counters adsl <shelf/slot/port>


Usetheclearcountersadsl*commandtoclearselectedADSLinterfacecounters.Usage
ExamplesThefollowingexampleclearsallcountersassociatedwiththeADSL1interface:
>enable#clearcountersadsl1

Functional Notes
CommandsforclearingspecificADSLcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
90219

2-34

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters backplane <shelf/slot/port>


Usetheclearcountersbackplane<shelf/slot/port>commandtoclearallbackplaneinterface
countersonaspecifiedshelf,slot,andport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersbackplane<shelf/slot/port>
command.
#clear counters backplane 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),QuadGigELM(1187550E1),QuadGigELM
(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65920

6TANV57CLI-35A

2-35

Total Access/NetVanta Carrier CLI Dictionary

clear counters dynamic-counter <shelf/slot/index>


Usetheclearcountersdynamiccounter<shelf/slot/index>commandtoclearthecountersfor
theselecteddynamiccounterinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersdynamiccounter<shelf/slot/
index>command.
#clear counters dynamic-counter 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),QuadGigELM(1187550G2),VDSL2Combo24P
AM(1187120L1),VDSL2AM(1187121L1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46057

2-36

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters e1 <shelf/slot/port>


Usetheclearcounterse1<shelf/slot/port>commandtoclearthecountersfortheselectedE1
interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounterse1<shelf/slot/port>command.
#clear counters e1 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),NV814(1200637G4),NV818
(1200637G2)

Command ID
45619

6TANV57CLI-35A

2-37

Total Access/NetVanta Carrier CLI Dictionary

clear counters efm-group <shelf/slot/group>


Usetheclearcountersefmgroup<shelf/slot/port>commandtoclearthecountersforthe
selectedEFMgroupinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersefmgroup<shelf/slot/group>
command.
#clear counters efm-group 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44958

2-38

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>]
Usetheclearcountersefmlink<shelf/slot/port>commandtoclearthecountersforthe
selectedEFMlinkinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersefmlink[<shelf/slot/
port>|<shelf/slot/port:chan>]command.
#clear counters efm-link 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44962

6TANV57CLI-35A

2-39

Total Access/NetVanta Carrier CLI Dictionary

clear counters efm-port <shelf/slot/port>


Usetheclearcountersefmport<shelf/slot/port>commandtoclearthecountersonthe
specifiedEFMport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersefmport<shelf/slot/port>
command.
#clear counters efm-link 1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
77531

2-40

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters erps <shelf/slot/ring>


Usetheclearcounterserps<shelf/slot/ring>commandtoclearthecountersonthespecified
ERPSring.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounterserps<shelf/slot/ring>command.
#clear counters erps 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77121

6TANV57CLI-35A

2-41

Total Access/NetVanta Carrier CLI Dictionary

clear counters ethernet [<shelf/slot/port>|cfm]


Usetheclearcountersethernet[<shelf/slot/port>|cfm]commandtoclearthecountersforall
Ethernetinterfacesonallportsoronaspecifiedport.

Syntax Description
ethernet

ClearcountersonallEthernetinterfaces

<shelf/slot/port>

ClearcountersontheselectedEthernetinterface

cfm

ClearEthernetCFMstatisticsheldbyMEPs

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernet[<shelf/slot/port>|cfm]
command.
#clear counters ethernet 1/0/3
#

Functional Notes
UsetheCFMoptiontoclearallcountersassociatedwiththeEthernetCFM(802.1ag)
subsystem.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44623

2-42

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ethernet cfm association WORD


UsetheclearcountersethernetcfmassociationWORDcommandtoclearallcountersinthe
EthernetCFM(802.1ag)subsystemassociatedwiththespecifiedmaintenanceassociation.

Usage Examples
ThefollowingisanexampleofhowtousetheclearcountersethernetcfmassociationWORD
command.
#clear counters ethernet cfm association TEST_ASSOC
#

Functional Notes
UsetheWORDinputtospecifythenameofthemaintenanceassociation.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
86892

6TANV57CLI-35A

2-43

Total Access/NetVanta Carrier CLI Dictionary

clear counters ethernet cfm domain WORD


UsetheclearcountersethernetcfmdomainWORDcommandtoclearallcountersinthe
EthernetCFM(802.1ag)subsystemassociatedwiththespecifiedmaintenancedomain.

Usage Examples
ThefollowingisanexampleofhowtousetheclearcountersethernetcfmdomainWORD
command.
#clear counters ethernet cfm domain TEST_DOMAIN
#

Functional Notes
UsetheWORDinputtospecifythenameofthemaintenancedomain.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
86888

2-44

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ethernet cfm down


UsetheclearcountersethernetcfmdowncommandtoclearallcountersintheEthernetCFM
(802.1ag)subsystemassociatedwithdownMEPs.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfmdowncommand.
#clear counters ethernet cfm down
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
86895

6TANV57CLI-35A

2-45

Total Access/NetVanta Carrier CLI Dictionary

clear counters ethernet cfm interface efm-group <shelf/slot/


group>
Usetheclearcountersethernetcfminterfaceefmgroup<shelf/slot/group>commandtoclear
allcountersintheEthernetCFM(802.1ag)subsystemassociatedwithMEPsplacedonthe
specifiedefmgroup.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfminterfaceefmgroup
<shelf/slot/group>command.
#clear counters ethernet cfm interface efm-group 1/0/3
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
86904

2-46

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ethernet cfm interface ethernet <shelf/slot/port>


Usetheclearcountersethernetcfminterfaceethernet<shelf/slot/port>commandtoclearall
countersintheEthernetCFM(802.1ag)subsystemassociatedwithMEPsplacedonthe
specifiedethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfminterfaceethernet
<shelf/slot/port>command.
#clear counters ethernet cfm interface ethernet 1/0/3
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
86900

6TANV57CLI-35A

2-47

Total Access/NetVanta Carrier CLI Dictionary

clear counters ethernet cfm interface gigabit-ethernet <shelf/


slot/port>
Usetheclearcountersethernetcfminterfacegigabitethernet<shelf/slot/port>commandto
clearallcountersintheEthernetCFM(802.1ag)subsystemassociatedwithMEPsplacedon
thespecifiedgigabitethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfminterfacegigabit
ethernet<shelf/slot/port>command.
#clear counters ethernet cfm interface gigabit-ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
86902

2-48

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ethernet cfm level <0-7>


Usetheclearcountersethernetcfmlevel<07>commandtoclearallcountersintheEthernet
CFM(802.1ag)subsystemassociatedwithMEPsthatareassociatedwithadomainconfigured
forthespecifiedmaintenancelevel.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfmlevel<07>
command.
#clear counters ethernet cfm level 5
#

Functional Notes
Usethe<07>inputtospecifythemaintenancelevel.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
86890

6TANV57CLI-35A

2-49

Total Access/NetVanta Carrier CLI Dictionary

clear counters ethernet cfm mep <1-8191>


Usetheclearcountersethernetcfmmep<18191>commandtoclearallcountersinthe
EthernetCFM(802.1ag)subsystemassociatedwithanyMEPconfiguredtohavethespecified
MEPidentifier.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfmmep<18191>
command.
#clear counters ethernet cfm mep 1000
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
86897

2-50

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ethernet cfm vlan [<1-4094>|none]


Usetheclearcountersethernetcfmvlan[<14094>|none]commandtoclearallcountersinthe
EthernetCFM(802.1ag)subsystemassociatedwithanyMEPoperatingonthespecified
VLAN.TheVLANlistisdefinedaspartofcomponentcreation.

Syntax Description
<14094>

SpecifyVLANid

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersethernetcfmvlan[<1
4094>|none]command.
! To clear counters on a specified VLAN:
#clear counters ethernet cfm vlan 2000
#
! To clear all counters in the subsystem:
#clear counters ethernet cfm vlan none
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
86893

6TANV57CLI-35A

2-51

Total Access/NetVanta Carrier CLI Dictionary

clear counters evc WORD


UsetheclearcountersevcWORDcommandtoclearselectedEVCinterfacecountersonall
slots.

Usage Examples
ThefollowingisanexampleofhowtousetheclearcountersevcWORDcommand.
#clear counters evc VIDEO_EVC
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90231

2-52

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters evc WORD <shelf/slot>


UsetheclearcountersEVC**commandtoclearselectedEVCinterfacecountersonthe
selectedslot.UsageExamplesThefollowingexampleclearsallcountersassociatedwiththe
EVCVIDEO_EVCinterfaceontheselectedslot:>enable#clearcountersevcVIDEO_EVC1/1

Syntax Description
WORD

ClearcountersontheselectedEVConallslots

Functional Notes
CommandsforclearingspecificEVCcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104883

6TANV57CLI-35A

2-53

Total Access/NetVanta Carrier CLI Dictionary

clear counters evc WORD <shelf/slot> ip igmp


UsetheclearcountersEVC**ipigmpcommandtoclearselectedEVCinterfaceIGMP
countersontheselectedslot.UsageExamplesThefollowingexampleclearsallIGMPcounters
associatedwiththeEVCVIDEO_EVCinterfaceontheselectedslot:>enable#clearcounters
evcVIDEO_EVC1/1ipigmp

Syntax Description
WORD

ClearcountersontheselectedEVConallslots

<shelf/slot>

ClearcountersontheselectedEVConselectedslot

Functional Notes
CommandsforclearingspecificEVCIGMPcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
104887

2-54

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters evc-map WORD <shelf/slot>


UsetheclearcountersevcmapWORD<shelf/slot>commandtoclearselectedEVCmap
interfacecounters.

Syntax Description
WORD

ClearcountersontheselectedEVCMap

Usage Examples
ThefollowingisanexampleofhowtousetheclearcountersevcmapWORD<shelf/slot>
command.
#clear counters evc-map VIDEO 1/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
90232

6TANV57CLI-35A

2-55

Total Access/NetVanta Carrier CLI Dictionary

clear counters frame-relay [<shelf/slot/group>|dlci]


Syntax Description
framerelay

ClearcountersforallFrameRelayGroups

<shelf/slot/group>

ClearcountersfortheselectedFrameRelayGroup

dlci

ClearcountersfortheallFrameRelayGroupPVCs

Functional Notes
Commandsforclearingframerelaycounters

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133771

2-56

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters frame-relay <shelf/slot/group> dlci


Syntax Description
<shelf/slot/group>

ClearcountersfortheselectedFrameRelayGroup

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133773

6TANV57CLI-35A

2-57

Total Access/NetVanta Carrier CLI Dictionary

clear counters frame-relay <shelf/slot/group> dlci <16-991>


Syntax Description
<shelf/slot/group>

ClearcountersfortheselectedFrameRelayGroup

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133774

2-58

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters fxs <shelf/slot/port>


Usetheclearcountersfxs<shelf/slot/port>commandtoclearthecountersfortheselectedFXS
interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersfxs<shelf/slot/port>command.
#clear counters fxs 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96500

6TANV57CLI-35A

2-59

Total Access/NetVanta Carrier CLI Dictionary

clear counters gigabit-ethernet <shelf/slot/port>


Usetheclearcountersgigabitethernet<shelf/slot/port>commandtoclearcountersonall
gigabitethernetinterfacesortheoptionallyspecifiedgigabitethernetinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersgigabitethernet<shelf/slot/port>
command.
#clear counters gigabit-ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44629

2-60

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters hdsl2 <shelf/slot/port>


Usetheclearcountershdsl2<shelf/slot/port>commandtoclearthecountersfortheselected
HDSL2interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountershdsl2<shelf/slot/port>
command.
#clear counters hdsl2 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43760

6TANV57CLI-35A

2-61

Total Access/NetVanta Carrier CLI Dictionary

clear counters hdsl4 <shelf/slot/port>


Usetheclearcountershdsl4<shelf/slot/port>commandtoclearthecountersfortheselected
HDSL4interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountershdsl4<shelf/slot/port>
command.
#clear counters hdsl4 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
43764

2-62

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters lacp <shelf/slot>


Usetheclearcounterslacp<shelf/slot>commandtoclearthecountersfortheLACPstatistics
forthespecifiedslot.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounterslacp<shelf/slot>command.
#clear counters lacp 1/0
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
104798

6TANV57CLI-35A

2-63

Total Access/NetVanta Carrier CLI Dictionary

clear counters muxponder-highspeed <shelf/slot/port>


Usetheclearcountersmuxponderhighspeed*commandtoclearselectedMuxponder
Highspeedinterfacecounters.UsageExamplesThefollowingexampleclearsallcounters
associatedwiththeMuxponderHighspeed0/3interface:>enable#clearcountersmuxponder
highspeed0/3

Functional Notes
CommandsforclearingspecificMuxponderHighspeedcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145692

2-64

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters muxponder-midspeed <shelf/slot/port>


Usetheclearcountersmuxpondermidspeed*commandtoclearselectedMuxponder
Midspeedinterfacecounters.UsageExamplesThefollowingexampleclearsallcounters
associatedwiththeMuxponderMidspeed0/3interface:>enable#clearcountersmuxponder
midspeed0/3

Functional Notes
CommandsforclearingspecificMuxponderMidspeedcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145690

6TANV57CLI-35A

2-65

Total Access/NetVanta Carrier CLI Dictionary

clear counters packet-timing <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
150625

2-66

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters policer WORD


UsetheclearcounterspolicerWORDcommandtoclearcountersonallpolicersorthe
optionallyspecifiedpolicer.

Usage Examples
ThefollowingisanexampleofhowtousetheclearcounterspolicerWORDcommand.
#clear counters policer
#
#clear counters policer POL1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82042

6TANV57CLI-35A

2-67

Total Access/NetVanta Carrier CLI Dictionary

clear counters ppp-group <shelf/slot/group>


Usetheclearcounterspppgroup<shelf/slot/group>commandtoclearcountersonthe
specifiedpppgroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89336

2-68

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>]
Usetheclearcountersppplink<shelf/slot/port>commandtoclearcountersonspecifiedppp
link.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89472

6TANV57CLI-35A

2-69

Total Access/NetVanta Carrier CLI Dictionary

clear counters probe responder twamp


UsetheclearcountersproberespondertwampcommandtoclearalloftheTwowayActive
MeasurementProtocol(TWAMP)proberespondercounters.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersproberespondertwamp
command.
#clear counters probe responder twamp
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46093

2-70

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters pseudowire [<shelf/slot>|<shelf/slot/pwe>]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131191

6TANV57CLI-35A

2-71

Total Access/NetVanta Carrier CLI Dictionary

clear counters shdsl <shelf/slot/port>


Usetheclearcountersshdsl<shelf/slot/port>commandtoclearcountersonallSHDSLinter
facesortheoptionallyselectedSHDSLinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersshdsl<shelf/slot/port>command.
#clear counters shdsl 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42502

2-72

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


Usetheclearcounterst1<shelf/slot/port>commandtoclearthecountersfortheselectedT1
interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounterst1[<shelf/slot/port>|<shelf/slot/
port:chan>]command.
#clear counters t1 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45457

6TANV57CLI-35A

2-73

Total Access/NetVanta Carrier CLI Dictionary

clear counters t3 <shelf/slot/port>


Usetheclearcounterst3<shelf/slot/port>commandtoclearthecountersfortheselectedT3
interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcounterst3<shelf/slot/port>command.
#clear counters t3 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42507

2-74

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear counters ten-gigabit-ethernet <shelf/slot/port>


Usetheclearcounterstengigabitethernet*commandtoclearselectedTenGigabitEthernet
interfacecounters.UsageExamplesThefollowingexampleclearsallcountersassociatedwith
theTenGigabitEthernet0/3interface:>enable#clearcounterstengigabitethernet0/3

Functional Notes
CommandsforclearingspecificTenGigabitEthernetcounters

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67095

6TANV57CLI-35A

2-75

Total Access/NetVanta Carrier CLI Dictionary

clear counters vdsl <shelf/slot/port>


Usetheclearcountersvdsl<shelf/slot/port>commandtoclearthecurrentfreerunning,
rollingcountersontheselectedVDSLphysicalinterfaceandport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearcountersvdsl<shelf/slot/port>command.
#clear counters vdsl 1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
86821

2-76

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ethernet cfm mep remote association WORD


UsetheclearethernetcfmmepremoteassociationWORDcommandtocleartheMEPCCM
databaseofMEPswithaspecifiedname,orbydefault,withallassociations.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremoteassociation
WORDcommand.
#clear ethernet cfm mep remote association myAssoc
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35167

6TANV57CLI-35A

2-77

Total Access/NetVanta Carrier CLI Dictionary

clear ethernet cfm mep remote domain WORD


UsetheclearethernetcfmmepremotedomainWORDcommandtocleartheMEPCCM
databaseofMEPswithaspecifieddomain,orbydefault,withalldomains.

Usage Examples
ThefollowingisanexampleofhowtousetheclearethernetcfmmepremotedomainWORD
command.
#clear ethernet cfm mep remote domain myDom
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35163

2-78

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ethernet cfm mep remote down


UsetheclearethernetcfmmepremotedowncommandtocleartheMEPCCMdatabaseof
MEPsinthedowndirection.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremotedown
command.
#clear ethernet cfm mep remote down
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35170

6TANV57CLI-35A

2-79

Total Access/NetVanta Carrier CLI Dictionary

clear ethernet cfm mep remote interface efm-group <shelf/slot/


group>
Usetheclearethernetcfmmepremoteinterfaceefmgroup<shelf/slot/group>commandto
cleartheMEPCCMdatabaseofMEPsconfiguredonthespecifiedEFMgroup.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremoteinterfaceefm
group<shelf/slot/group>command.
#clear ethernet cfm mep remote interface efm-group 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35181

2-80

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ethernet cfm mep remote interface ethernet <shelf/slot/


port>
Usetheclearethernetcfmmepremoteinterfaceethernet<shelf/slot/port>commandtoclear
theMEPCCMdatabaseofMEPsconfiguredonthespecifiedEthernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremoteinterface
ethernet<shelf/slot/port>command.
#clear ethernet cfm mep remote interface ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35177

6TANV57CLI-35A

2-81

Total Access/NetVanta Carrier CLI Dictionary

clear ethernet cfm mep remote interface gigabit-ethernet


<shelf/slot/port>
Usethecleargigabitethernetcfmmepremoteinterfaceethernet<shelf/slot/port>command
tocleartheMEPCCMdatabaseofMEPsconfiguredonthespecifiedGigabitEthernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremoteinterfacegigabit
ethernet<shelf/slot/port>command.
#clear ethernet cfm mep remote interface gigabit-ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35179

2-82

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ethernet cfm mep remote level <0-7>


Usetheclearethernetcfmmepremotelevel<07>commandtocleartheMEPCCMdatabase
ofMEPsataspecifiedlevel,orbydefault,onalllevels.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremotelevel<07>
command.
#clear ethernet cfm mep remote level 7
#

Functional Notes
Thevalidrangeforthelevelis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35165

6TANV57CLI-35A

2-83

Total Access/NetVanta Carrier CLI Dictionary

clear ethernet cfm mep remote local-mep <1-8191>


Usetheclearethernetcfmmepremotelocalmep<18191>commandtocleartheMEPCCM
databaseofMEPswithaspecifiedlocalMEPID,orbydefault,alllocalMEPs.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremotelocalmep<1
8191>command.
#clear ethernet cfm mep remote local-mep 200
#

Functional Notes
ThevalidrangefortheMEPIDis18191.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35172

2-84

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ethernet cfm mep remote remote-mep <1-8191>


Usetheclearethernetcfmmepremoteremotemep<18191>commandtocleartheMEPCCM
databaseofMEPswithaspecifiedremoteMEPID,orbydefault,allremoteMEPs.

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremoteremotemep<1
8191>command.
#clear ethernet cfm mep remote remote-mep 200
#

Functional Notes
ThevalidrangefortheMEPIDis18191.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35174

6TANV57CLI-35A

2-85

Total Access/NetVanta Carrier CLI Dictionary

clear ethernet cfm mep remote vlan [<1-4094>|none]


Usetheclearethernetcfmmepremotevlan[<14094>|none]commandtocleartheMEPCCM
databaseofMEPs.

Syntax Description
<14094>

SpecifyVLANID

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisanexampleofhowtousetheclearethernetcfmmepremotevlan[<1
4094>|none]command.
#clear ethernet cfm mep remote vlan 100
#

Functional Notes
Usethe<14094>inputtocleartheMEPCCMdatabaseofMEPsonaspecifiedVLAN.The
validrangefortheVLANIDis14094.
UsethenoneoptiontocleartheMEPCCMdatabaseofMEPsthatarenotassociatedwithany
VLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35168

2-86

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear ip file-server download-cache


Usetheclearipfileserverdownloadcachecommandtoclearthecontentsoftheremotefile
cacheoftheSCM.

Usage Examples
Thefollowingisanexampleofhowtousetheclearipfileserverdownloadcachecommand.
#clear ip file-server download-cache
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64025

6TANV57CLI-35A

2-87

Total Access/NetVanta Carrier CLI Dictionary

clear mac address-table <shelf/slot>


[authenticated|dynamic|multicast|static]
Usetheclearmacaddresstable<shelf/slot>[authenticated|dynamic|multicast|static]
commandtoclearalllearnedMACaddressesonthespecifiedshelfandslotusingthe
additionalsyntaxtonarrowtheselectiontoauthenticated,learned,multicastorstaticentries.

Syntax Description
<shelf/slot>

Entershelfandslot

authenticated

Authenticatedentries

dynamic

Learnedentries

multicast

Multicastentries

static

Staticentries

Usage Examples
Thefollowingisanexampleofhowtousetheclearmacaddresstable<shelf/slot>[authenti
cated|dynamic|multicast|static]command.
! To clear all entries on a specified shelf and slot
#clear mac address-table 1/0
#
! To clear all learned entries on a specified shelf and slot
#clear mac address-table 1/0 dynamic
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),ADSL2AM(1187101E1),
ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),GPONAM
(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

2-88

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
88407

6TANV57CLI-35A

2-89

Total Access/NetVanta Carrier CLI Dictionary

clear mac address-table <shelf/slot> address xx:xx:xx:xx:xx:xx


Usetheclearmacaddresstable<shelf/slot>addressxx:xx:xx:xx:xx:xxcommandtocleara
specifiedMACaddressonaspecifiedshelfandslot.

Syntax Description
<shelf/slot>

Entershelfandslot

Usage Examples
Thefollowingisanexampleofhowtousetheclearmacaddresstable<shelf/slot>address
xx:xx:xx:xx:xx:xxcommand.
#clear mac address-table 1/0 address 00:00:00:00:00:00
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101759

2-90

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear mac address-table interface ethernet <shelf/slot/port>


Usetheclearmacaddresstableinterfaceethernet<shelf/slot/port>commandtoclearthe
learnedMACaddressesfromthespecifiedethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearmacaddresstableinterfaceethernet
<shelf/slot/port>command.
#clear mac address-table interface ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
90312

6TANV57CLI-35A

2-91

Total Access/NetVanta Carrier CLI Dictionary

clear mac address-table interface gigabit-ethernet <shelf/slot/


port>
Usetheclearmacaddresstableinterfacegigabitethernet<shelf/slot/port>commandtoclear
thelearnedMACaddressesfromthespecifiedgigabitethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearmacaddresstableinterfacegigabit
ethernet<shelf/slot/port>command.
#clear mac address-table interface gigabit-ethernet 1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90314

2-92

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear node-information <1-n>


Usetheclearcounterscommandtoclearallinterfacecountersoronlythecountersfora
specifiedinterface.Thiscommanddoesnotclearperformancemonitoringstatistics.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
153906

6TANV57CLI-35A

2-93

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics [adsl|backplane|e1|efmgroup|efm-link|erps|ethernet|evc|evc-map|frame-relay|gigabitethernet|gpon|hdsl2|hdsl4|muxponder-highspeed|muxpondermidspeed|policer|ppp-group|ppplink|pseudowire|shdsl|t1|t3|ten-gigabit-ethernet|vdsl]


Usetheclearperformancestatisticscommandtoclearallperformancestatisticsforthe
specifiedinterface.

Syntax Description

2-94

adsl

AllADSLinterfaces

backplane

Allbackplaneinterfaces

e1

AllE1interfaces

efmgroup

AllEFMgroups

efmlink

AllEFMlinks

erps

AllERPSinterfaces

ethernet

AllEthernetinterfaces

evc

AllEVCs

evcmap

AllEVCMapsinterfaces

framerelay

AllFrameRelayGroups

gigabitethernet

AllGigabitEthernetinterfaces

gpon

AllGPONinterfaces

hdsl2

AllHDSL2interfaces

hdsl4

AllHDSL4interfaces

muxponderhighspeed

AllMuxponderHighspeedinterfaces

muxpondermidspeed

AllMuxponderMidspeedinterfaces

policer

Allpolicers

pppgroup

AllPPPgroups

ppplink

AllPPPlinks

pseudowire

AllPseudowireinterfaces

shdsl

AllSHDSLinterfaces

t1

AllT1interfaces

t3

AllT3interfaces

6TANV57CLI-35A

Section 2, Commands - Common Commands

tengigabitethernet

AllTenGigabitEthernetinterfaces

vdsl

AllVDSLinterfaces

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatistics
[adsl|backplane|e1|efmgroup|efmlink|erps|ethernet|evc|evcmap|framerelay|gigabit
ethernet|gpon|hdsl2|hdsl4|muxponderhighspeed|muxpondermidspeed|policer|ppp
group|ppplink|pseudowire|shdsl|t1|t3|tengigabitethernet|vdsl]command.
#clear performance-statistics gigabit-ethernet
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1),FIBERAM(1187552G1),Quad
GigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ActiveEth24PortAM(1187560F1),
10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),EFME1AM
(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),EFMBonding
ProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFM
DS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),
GPONAM(1187501G1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),
NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV
834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),
NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV
8044(1172804G1)

Command ID
63645

6TANV57CLI-35A

2-95

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics adsl <shelf/slot/port>


Usetheclearperformancestatisticsadsl<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedADSLinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsadsl<shelf/slot/
port>command.
#clear performance-statistics adsl <shelf/slot/port>
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
90223

2-96

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics backplane <shelf/slot/port>


Usetheclearperformancestatisticsbackplane<shelf/slot/port>commandtoclearselected
backplaneinterfaceperformancestatistics.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsbackplane<shelf/
slot/port>command.
#clear performance-statistics backplane 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),QuadGigELM(1187550E1),QuadGigELM
(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67118

6TANV57CLI-35A

2-97

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics e1 <shelf/slot/port>


Usetheclearperformancestatisticse1<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedE1interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticse1<shelf/slot/port>
command.
#clear performance-statistics e1 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
63646

2-98

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics efm-group <shelf/slot/group>


Usetheclearperformancestatisticsefmgroup<shelf/slot/group>commandtoclearperfor
mancestatisticsforthespecifiedEFMgroup.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsefmgroup<shelf/
slot/group>command.
#clear performance-statistics efm-group 1/0/3
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44960

6TANV57CLI-35A

2-99

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics efm-link [<shelf/slot/port>|<shelf/


slot/port:chan>]
Usetheclearperformancestatisticsefmlink<shelf/slot/port>commandtocleartheperfor
mancestatisticsforthespecifiedEFMlink.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsefmlink[<shelf/
slot/port>|<shelf/slot/port:chan>]command.
#clear performance-statistics efm-link 1/0/2
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44964

2-100

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics erps <shelf/slot/ring>


Usetheclearperformancestatisticserps<shelf/slot/ring>commandtocleartheringperfor
mancemonitoringstatisticsonthespecifiedERPSinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticserps<shelf/slot/
ring>command.
#clear performance-statistics erps 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77123

6TANV57CLI-35A

2-101

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics ethernet <shelf/slot/port>


Usetheclearperformancestatisticsethernet<shelf/slot/port>commandtoclearperformance
statisticsforthespecifiedethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsethernet<shelf/slot/
port>command.
#clear performance-statistics ethernet 1/0/4
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
63648

2-102

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics evc WORD


UsetheclearperformancestatisticsevcWORDcommandtoclearallEVCinterfaceperfor
mancestatisticsforaspecifiedEVCnameonallslots.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ComboAM(1187100L1),ComboAM(1187100L2),GPONAM
(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90273

6TANV57CLI-35A

2-103

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics evc WORD <shelf/slot>


UsetheclearperformancestatisticsevcWORD<shelf/slot>commandtoclearallEVC
interfaceperformancestatisticsforaspecifiedEVCnameandslot.

Syntax Description
WORD

SpecifiedEVCname

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104884

2-104

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics evc-map WORD <shelf/slot>


UsetheclearperformancestatisticsevcmapWORD<shelf/slot>commandtocleartheperfor
mancemonitoringstatisticsonthespecifiedEVCmap.

Syntax Description
WORD

SpecifiedEVCMapname

Usage Examples
ThefollowingisanexampleofhowtousetheclearperformancestatisticsevcmapWORD
<shelf/slot>command.
#clear performance-statistics evc-map MAP1 1/0
#

Functional Notes
UsetheWORDinputtodesignatethenameofthepreviouslycreatedEVCmap.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
90271

6TANV57CLI-35A

2-105

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics frame-relay [<shelf/slot/


group>|dlci]
Syntax Description
framerelay

AllFrameRelayGroups

<shelf/slot/group>

SpecifiedFrameRelayGroup

dlci

AllFrameRelayGroupPVCs

Functional Notes
Commandsforclearingframerelayperformancestatistics

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133776

2-106

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics frame-relay <shelf/slot/group>


dlci
Syntax Description
<shelf/slot/group>

SpecifiedFrameRelayGroup

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133778

6TANV57CLI-35A

2-107

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics frame-relay <shelf/slot/group>


dlci <16-991>
Syntax Description
<shelf/slot/group>

SpecifiedFrameRelayGroup

Functional Notes
CommandsforclearingspecificframerelayPVCperformancestatistics

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133779

2-108

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics gigabit-ethernet <shelf/slot/port>


Usetheclearperformancestatisticsgigabitethernet<shelf/slot/port>commandtoclear
performancestatisticsforthespecifiedgigabitethernetport.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsgigabitethernet
<shelf/slot/port>command.
#clear performance-statistics gigabit-ethernet 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
63647

6TANV57CLI-35A

2-109

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics gpon <shelf/slot/port>


UsetheclearperformancestatisticsgponcommandtoclearallGPONinterfaceperformance
statistics.

Functional Notes
CommandsforclearingspecificGPONperformancestatistics

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136728

2-110

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics hdsl2 <shelf/slot/port>


Usetheclearperformancestatisticshdsl2<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedHDSL2interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticshdsl2<shelf/slot/
port>command.
#clear performance-statistics hdsl2 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
63649

6TANV57CLI-35A

2-111

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics hdsl4 <shelf/slot/port>


Usetheclearperformancestatisticshdsl4<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedHDSL4interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticshdsl4<shelf/slot/
port>command.
#clear performance-statistics hdsl4 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
63650

2-112

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics muxponder-highspeed <shelf/


slot/port>
Usetheclearperformancestatisticsmuxponderhighspeed<shelf/slot/port>commandto
clearselectedMuxponderHighspeedinterfaceperformancestatistics.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
150618

6TANV57CLI-35A

2-113

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics muxponder-midspeed <shelf/slot/


port>
Usetheclearperformancestatisticsmuxpondermidspeed<shelf/slot/port>commandtoclear
performancestatisticsforthespecifiedmuxpondermidspeedport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
150620

2-114

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics policer WORD


UsetheclearperformancestatisticspolicerWORDcommandtocleartheperformance
statisticsforthespecifiedpolicer.

Usage Examples
ThefollowingisanexampleofhowtousetheclearperformancestatisticspolicerWORD
command.
#clear performance-statistics policer policer1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82044

6TANV57CLI-35A

2-115

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics ppp-group <shelf/slot/group>


Usetheclearperformancestatisticspppgroup<shelf/slot/group>commandtoclearperfor
mancestatisticsforthespecifiedPPPgroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89339

2-116

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics ppp-link [<shelf/slot/port>|<shelf/


slot/port:chan>]
Usetheclearperformancestatisticsppplink<shelf/slot/port>commandtoclearperformance
statisticsforthespecifiedPPPlink.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsppplink[<shelf/
slot/port>|<shelf/slot/port:chan>]command.
! Example for a DS1:
#clear performanance-statistics ppp-link 1/3/1
#
! Example for a channelized DS3:
#clear performance-statistics ppp-link 1/3/1:1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89475

6TANV57CLI-35A

2-117

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics pseudowire [<shelf/slot>|<shelf/


slot/pwe>]
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131194

2-118

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics shdsl <shelf/slot/port>


Usetheclearperformancestatisticsshdsl<shelf/slot/port>commandtoclearperformance
statisticsfortheselectedSHDSLinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsshdsl<shelf/slot/
port>command.
#clear performance-statistics shdsl 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42504

6TANV57CLI-35A

2-119

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics t1 [<shelf/slot/port>|<shelf/slot/


port:chan>]
Usetheclearperformancestatisticst1<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedT1interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticst1[<shelf/slot/
port>|<shelf/slot/port:chan>]command.
#clear performance-statistics t1 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45458

2-120

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics t3 <shelf/slot/port>


Usetheclearperformancestatisticst3<shelf/slot/port>commandtocleartheperformance
monitoringstatisticsonthespecifiedT3interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticst3<shelf/slot/port>
command.
#clear performance-statistics t3 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42508

6TANV57CLI-35A

2-121

Total Access/NetVanta Carrier CLI Dictionary

clear performance-statistics ten-gigabit-ethernet <shelf/slot/


port>
Usetheclearperformancestatisticstengigabitethernet*commandtoclearselectedTen
GigabitEthernetinterfaceperformancestatistics.

Functional Notes
CommandsforclearingspecificTenGigabitEthernetperformancestatistics

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67097

2-122

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear performance-statistics vdsl <shelf/slot/port>


Usetheclearperformancestatisticscommandtoclearall15minuteand24hourinterval
performancestatisticsfortheselectedVDSLinterface/port.

Usage Examples
Thefollowingisanexampleofhowtousetheclearperformancestatisticsvdsl<shelf/slot/
port>command.
VDSL-AM>clear performance-statistics vdsl 1/19/1

Functional Notes
ClearingPMcantakeseveralsecondstocompletetheprocessandupdatestatisticsforall
ports.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
90221

6TANV57CLI-35A

2-123

Total Access/NetVanta Carrier CLI Dictionary

clear processes cpu max


UsetheclearprocessescpumaxcommandtoresetthemaximumCPUload.

Usage Examples
Thefollowingisanexampleofhowtousetheclearprocessescpumaxcommand.
#clear processes cpu max
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87746

2-124

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear processes cpu max <shelf/slot>


Usetheclearprocessescpumax<shelf/slot>commandtoresetthemaximumCPUloadona
specificslot.

Usage Examples
Thefollowingisanexampleofhowtousetheclearprocessescpumax<shelf/slot>command.
#clear processes cpu max 1/15
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
87747

6TANV57CLI-35A

2-125

Total Access/NetVanta Carrier CLI Dictionary

clear security account age all


Usetheclearsecurityaccountageallcommandtocleartheaccountageforallprovisioned
users.

Usage Examples
Thefollowingisanexampleofhowtousetheclearsecurityaccountageallcommand.
#clear security account age all
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64621

2-126

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear security account age username WORD


UsetheclearsecurityaccountageusernameWORDcommandtocleartheaccountagefora
specifiedusername.

Usage Examples
ThefollowingisanexampleofhowtousetheclearsecurityaccountageusernameWORD
command.
#clear security account age username newuser
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64625

6TANV57CLI-35A

2-127

Total Access/NetVanta Carrier CLI Dictionary

clear security password age all


Usetheclearsecuritypasswordageallcommandtoclearthepasswordageforallprovisioned
users.

Usage Examples
Thefollowingisanexampleofhowtousetheclearsecuritypasswordageallcommand.
#clear security password age all
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64672

2-128

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear security password age username WORD


UsetheclearsecuritypasswordageusernameWORDcommandtoclearthepasswordagefor
thespecifiedusername.

Usage Examples
ThefollowingisanexampleofhowtousetheclearsecuritypasswordageusernameWORD
command.
#clear security password age username newuser
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64627

6TANV57CLI-35A

2-129

Total Access/NetVanta Carrier CLI Dictionary

clear splice-detect [hdsl2|hdsl4|shdsl]


Usetheclearsplicedetect[hdsl2|hdsl4|shdsl]commandtoclearthesplicedetectonthe
selectedinterface.

Syntax Description
hdsl2

AllHDSL2interfaces

hdsl4

AllHDSL4interfaces

shdsl

AllSHDSLinterfaces

Usage Examples
Thefollowingisanexampleofhowtousetheclearsplicedetect[hdsl2|hdsl4|shdsl]
command.
#clear splice-detect hdsl2
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV824(1200634G4),NV
828(1200634G2),NV844(1200635G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
63986

2-130

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear splice-detect hdsl2 <shelf/slot/port>


Usetheclearsplicedetecthdsl2<shelf/slot/port>commandtoclearthesplicedetectonthe
specifiedportontheHDSL2interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearsplicedetecthdsl2<shelf/slot/port>
command.
#clear splice-detect hdsl2 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
79271

6TANV57CLI-35A

2-131

Total Access/NetVanta Carrier CLI Dictionary

clear splice-detect hdsl4 <shelf/slot/port>


Usetheclearsplicedetecthdsl4<shelf/slot/port>commandtoclearthesplicedetectonthe
specifiedportontheHDSL4interface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearsplicedetecthdsl4<shelf/slot/port>
command.
#clear splice-detect hdsl4 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
79273

2-132

6TANV57CLI-35A

Section 2, Commands - Common Commands

clear splice-detect shdsl <shelf/slot/port>


Usetheclearsplicedetectshdsl<shelf/slot/port>commandtoclearhistoricalsplicedetection
informationfortheselectedSHDSLinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheclearsplicedetectshdsl<shelf/slot/port>
command.
#clear splice-detect shdsl 1/0/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42503

6TANV57CLI-35A

2-133

Total Access/NetVanta Carrier CLI Dictionary

configure terminal
UsetheconfigureterminalcommandtoactivatetheGlobalConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousetheconfigureterminalcommand.
#configure terminal
(config)#

Functional Notes
ThepromptchangesasverificationthattheGlobalConfigurationCommandSetisavailable.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),EFMBondingProtectAM(1187250G1),EFMDS3CCAM
(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),FIBERAM
(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM
(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),Quad
GPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2
GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),
TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS
1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GE
HPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF
(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRD
RF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERF
RFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE
2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

2-134

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
46776

6TANV57CLI-35A

2-135

Total Access/NetVanta Carrier CLI Dictionary

copy WORD [WORD|running-config|startup-config]


Syntax Description
WORD

Filetocopyto

runningconfig

Applyfiletorunningconfig

startupconfig

Updatestartupconfigurationfromafile

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
100134

2-136

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy file-server flash


Usethecopyfileserverflashcommandtoupgradetheapplicationcodeusingafilelocatedon
anetworkfileserver.Thenewapplicationcodeiscopiedintotheflashmemoryoftheunit.
Theserverandprotocolusedarechosenbyconfigurationcommandsbeginningwithipfile
serverdefault.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM(1187125L1),ADSLAMwithVDSL
SplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CH
DS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2)

Command ID
66012

6TANV57CLI-35A

2-137

Total Access/NetVanta Carrier CLI Dictionary

copy file-server flash [<shelf/slot>|<remote-index>]


Usethecopyfileserverflash<shelf/slot>commandtoupgradetheapplicationcodeusinga
filelocatedonanetworkfileserver.Thenewapplicationcodeiscopiedintotheflashmemory
oftheunit.Theserverandprotocolusedarechosenbyconfigurationcommandsbeginning
withipfileserverdefault.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM(1187125L1),ADSLAMwithVDSL
SplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CH
DS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2)

Command ID
66013

2-138

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy file-server flash [<shelf/slot>|<remote-index>] WORD


Usethecopyfileserverflash<shelf/slot>WORDcommandtoupgradetheapplicationcode
usingafilelocatedonanetworkfileserver.Thenewapplicationcodeiscopiedintotheflash
memoryoftheunit.Theserverandprotocolusedarechosenbyconfigurationcommands
beginningwithipfileserverdefault.

Syntax Description
<shelf/slot>

Specifiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM(1187125L1),ADSLAMwithVDSL
SplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CH
DS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2)

Command ID
88824

6TANV57CLI-35A

2-139

Total Access/NetVanta Carrier CLI Dictionary

copy flash [ftp|tftp]


Syntax Description
ftp

ToFTP

tftp

Uploadfiletoaremoteserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
100140

2-140

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy ftp [flash|running-config|sca|startup-config]


Syntax Description
flash

Toflash

runningconfig

Applyingconfigurationontopofexistingrunningconfiguration

sca

Replaceexistingrunningconfiguration

startupconfig

Tostartupconfig

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
124059

6TANV57CLI-35A

2-141

Total Access/NetVanta Carrier CLI Dictionary

copy running-config [WORD|ftp|startup-config|tftp]


Usethecopyrunningconfig[startupconfig|tftp]commandtoreplacethestartupconfigu
rationwithacopyofthecurrentrunningconfigurationortosavethecurrentrunningconfig
urationtoaTFTPserver.

Syntax Description
WORD

Copycurrentsystemconfigurationtoafile

ftp

ToFTP

startupconfig

Powerupdeviceconfiguration

tftp

ToTFTP

Usage Examples
Thefollowingisanexampleofhowtousethecopyrunningconfig[WORD|ftp|startup
config|tftp]command.
#copy running-config startup-config
Save System Configuration?[y/n]y
Provisioning Saved
#copy running-config tftp
Address of remote host? [0.0.0.0]:10.44.3.207
Destination filename?config.txt
Initiating TFTP transfer...Press "C" to cancel
Ready for transfer

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46768

2-142

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy sca [ftp|tftp]


Usethecopyrunningconfigcommandtocreateacopyofthecurrentrunningconfiguration
andreplacethecurrentstartupconfigurationorsaveittoaspecifiedmemorylocation
(CompactFlashorsystemflash).UsageExamplesThefollowingexamplecopiesthecurrent
runningconfigurationtothestartupconfigurationlocatedinflashmemory:>enable#copy
runningconfigstartupconfigBuildingconfiguration...Done.Success!CommandReference
GuideEnableModeCommandSet60000CRGD35ACopyright2008ADTRAN,Inc.151The
followingexamplecopiesthecurrentrunningconfigurationtoCompactFlashmemoryand
namesthefileconfig_01.txt:>enable#copyrunningconfigcflashconfig_01.txtPercentCompete
100%#ThefollowingexamplecopiesthecurrentrunningconfigurationtoaTFTPserverand
namesthefileconfig_01.txt:>enable#copyrunningconfigtftpAddressofremotehost?
10.200.2.4Destinationfilename?config_01.txtInitiatingTFTPtransfer...Sent3099bytes.Transfer
Complete!

Syntax Description
ftp

ToFTP

tftp

ToTFTP

Functional Notes
CommandstocopytheSystemConfigurationAchive

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
78675

6TANV57CLI-35A

2-143

Total Access/NetVanta Carrier CLI Dictionary

copy startup-config [WORD|ftp|running-config|tftp]


Syntax Description
WORD

Copystartupconfigurationtoafile

ftp

ToFTP

runningconfig

Updatecurrentsystemconfiguration

tftp

CopytoaTFTPserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
100131

2-144

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy tftp [flash|running-config|sca|startup-config]


Usethecopytftpcommandtoupgradetheapplicationcode.

Syntax Description
flash

Toflash

runningconfig

Applyingconfigurationontopofexistingrunningconfiguration

sca

Applyingconfigurationontopofexistingrunningconfiguration

startupconfig

Copytothestartupconfiguration

Usage Examples
Thefollowingisanexampleofhowtousethecopytftp[flash|runningconfig|sca|startup
config]command.
#copy tftp flash
Address of remote host? [0.0.0.0]:10.44.3.207
Source filename?:upgrade.bin
Initiating TFTP transfer...Press "C" to cancel
Transfer in progress

Functional Notes
UsetheflashoptiontoupgradetheapplicationcodeusingafilelocatedonanetworkTFTP
server.Thenewapplicationcodeiscopiedintotheflashmemoryoftheunit.
Usetherunningconfigoptiontorestoreasavedrunningconfigurationontopoftheexisting
runningconfiguration.
UsethescaoptiontorestoreanSCAfileontopoftheexistingrunningconfiguration.Tohave
thecurrentrunningconfigurationmatchthatoftheunitthatcreatedthesavedrunningconfig
orSCA,issuetheerasestartupconfigcommandfollowedbythereloadcommandsothatthe
systemisinafactorydefaultstatepriortoapplyingthenewconfiguration.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-145

Total Access/NetVanta Carrier CLI Dictionary

Command ID
46256

2-146

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy xmodem [flash|running-config|startup-config]


Usethecopyxmodemcommandtocopyafile(usingtheXMODEMprotocol)toaspecified
destination.XMODEMcapabilityisprovidedinVT100terminalemulationsoftware,suchas
HyperTerminal.UsageExamplesThefollowingexamplecopiesasoftwarefile(myfile.biz)to
flashmemoryandlabelsitnewfile.biz:#copyxmodemflashDestinationfilename?
newfile.bizBegintheXmodemtransfernow...PressCTRL+XtwicetocancelCCCCCCAOSis
nowreadytoacceptthefileontheCONSOLEport(usingtheXMODEMprotocol).Thenext
stepintheprocessmaydifferdependingonthetypeofterminalemulationsoftwareyouare
using.ForHyperTerminal,youwillnowselectTransfer>SendFileandbrowsetothefileyou
wishtocopymyfile.biz.Oncethetransferiscomplete,informationsimilartothefollowingis
displayed:Received531424bytes.Transfercomplete

Syntax Description
flash

Toflash

runningconfig

Updatecurrentsystemconfiguration

startupconfig

Copytostartupconfiguration

Functional Notes
CopyfilesfromaXModemserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),ADSLAMwithVDSLSplitter
Comp(1187102G1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),
CHDS3FrameRelay3PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2),NV
824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
46264

6TANV57CLI-35A

2-147

Total Access/NetVanta Carrier CLI Dictionary

copy ymodem [flash|running-config|startup-config]


Usethecopyymodemcommandtocopyafile(usingtheYMODEMprotocol)toaspecified
destination.

Syntax Description
flash

Toflash

runningconfig

Updatecurrentsystemconfiguration

startupconfig

Copytostartupconfiguration

Functional Notes
CopyfilesfromaYModemserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46261

2-148

6TANV57CLI-35A

Section 2, Commands - Common Commands

copy ymodem flash <shelf/slot>


Usethecopyymodemflash<shelf/slot>commandtoupgradethefirmwareusingthe
YMODEMprotocol.Thenewfirmwareiscopiedintotheflashmemoryoftheunitonthe
specifiedslot.YMODEMcapabilityisprovidedinterminalemulationsoftwaresuchas
HyperTerminal.

Usage Examples
Thefollowingisanexampleofhowtousethecopyymodemflash<shelf/slot>command.
#copy ymodem flash 0/1
Please wait
Software Upload
Expecting Y-Modem Transfer...
Press ESC to cancel
CCCC
#

Functional Notes
Thenextstepintheprocesscandifferdependingonthetypeofterminalemulationsoftware
used.ForHyperTerminal,selectTransferthenSendFileandbrowsetothefiletocopy.
Oncethetransferiscomplete,thefirmwareimageisverifiedandwrittentoflash.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

6TANV57CLI-35A

2-149

Total Access/NetVanta Carrier CLI Dictionary

Command ID
46263

2-150

6TANV57CLI-35A

Section 2, Commands - Common Commands

disable
Usethedisablecommandtoexittheprivilegedmodeandenterthebasicmode.

Usage Examples
Thefollowingisanexampleofhowtousethedisablecommand.
#disable
>

Functional Notes
Thepromptchangesasverificationthatthebasicmodecommandsareavailable.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-151

Total Access/NetVanta Carrier CLI Dictionary

Command ID
46771

2-152

6TANV57CLI-35A

Section 2, Commands - Common Commands

enable
Usetheenablecommandtoentertheprivilegedcommandmode.

Usage Examples
Thefollowingisanexampleofhowtousetheenablecommand.
! Example without password requirement
>enable
#
! Example with password requirement
>enable
Password: ******
#

Functional Notes
Theenablecommandcanrequireapassword.Thepromptchangesasverificationthatthe
privilegedmodecommandsareavailable.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE

6TANV57CLI-35A

2-153

Total Access/NetVanta Carrier CLI Dictionary

SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46772

2-154

6TANV57CLI-35A

Section 2, Commands - Common Commands

erase [WORD|startup-config]
Usetheerase[runningconfig|startupconfig]commandtoerasetherunningorstartup
configuration.

Syntax Description
WORD

Thefilenametodeletefromthefilesystem

startupconfig

Erasethestartupconfigurationfilestoredinflashmemory

Usage Examples
Thefollowingisanexampleofhowtousetheerase[WORD|startupconfig]command.
! Erase the current running configuration.
#erase running-config
Restore Factory Defaults?[y/n]y
Factory Defaults Loaded
Save System Configuration?[y/n]y
Provisioning Saved
! Erase the startup configuration.
#erase startup-config
Startup configuration erased.
#reload
Save System Configuration?[y/n]n
You are about to reboot the system. Continue?[y/n]y

Functional Notes
Usetherunningconfigoptiontorestorethesystemtodefaultsettingsimmediatelywithout
requiringareboot.Therunningconfigoptiondoesnotdeletealluserconfigurableoptions
(forexample,IPsettingsandsecuritysystem).
Usethestartupconfigoptiontodeletetheconfigurationsavedinflashthatisusedonstartup.
Thestartupconfigoptiondeletesalluserconfigurableoptions,butdoesnotcauseachangein
systembehavioruntilareloadoccurs.Ifpromptedtosaveconfigurationpriortoreload,do
notsaveitasitsavesthecurrentrunningconfigurationtoflashandundoesthecommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-155

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46502

2-156

6TANV57CLI-35A

Section 2, Commands - Common Commands

erase startup-config <shelf/slot>


Usetheerasestartupconfig<shelf/slot>commandtoerasethestartupconfigurationstoredin
flashmemory.Ifanewstartupconfigurationfileisnotspecifiedbeforepowercyclingtheunit,
theoperatingsysteminitializesusingablankconfiguration.

Usage Examples
Thefollowingisanexampleofhowtousetheerasestartupconfig<shelf/slot>command.
#erase startup-config 1/1
Restore Factory Defaults?[y/n]y

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46504

6TANV57CLI-35A

2-157

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Functional Notes
ExitfromtheCLIsession

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46773

2-158

6TANV57CLI-35A

Section 2, Commands - Common Commands

force alarm [acknowledge|clear|reset|resync]


Usetheforcealarm[acknowledge|clear|reset|resync]commandtoacknowledge,clear,reset,
orresynchronizealarmsfromthealarmlog.

Syntax Description
acknowledge

Acknowledgeallalarms

clear

Clearallalarms

reset

Resetallalarms

resync

Resyncallalarms

Usage Examples
Thefollowingisanexampleofhowtousetheforcealarm[acknowledge|clear|reset|resync]
command.
#force alarm acknowledge
#

Functional Notes
Usetheacknowledgeoptiontomarkallcurrententriesinthealarmlogasacknowledged.
Acknowledgingalarmspreventstheconditionofthealarmfromtriggeringexternalevents,
suchasalarmrelays,andmakesthealarmseligibletobeclearedfromthealarmlog.The
conditionalsomusthavepassedforthealarmtobecleared.
Usetheclearoptiontoremoveallacknowledgedandinactivealarmsfromthealarmlog.The
clearoptionremovestheclutterfromthealarmlogandmakesitpossibletoclearlyseethe
currentactivealarmsinthesystem.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
67311

6TANV57CLI-35A

2-159

Total Access/NetVanta Carrier CLI Dictionary

force alarm acknowledge <shelf/slot>


Usetheforcealarmacknowledge<shelf/slot>commandtoacknowledgealarmsinthealarm
logforthespecifiedmodule.Acknowledgingalarmspreventstheconditionofthealarmfrom
triggeringexternalevents,suchasalarmrelays,andmakesthealarmseligibletobecleared
fromthealarmlog.Theconditionalsomusthavepassedforthealarmtobecleared.

Usage Examples
Thefollowingisanexampleofhowtousetheforcealarmacknowledge<shelf/slot>
command.
#force alarm acknowledge 1/0
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66174

2-160

6TANV57CLI-35A

Section 2, Commands - Common Commands

force alarm clear <shelf/slot>


Usetheforcealarmclear<shelf/slot>commandtoclearallacknowledgedalarmsforthe
specifiedshelf/slot.

Usage Examples
Thefollowingisanexampleofhowtousetheforcealarmclear<shelf/slot>command.
#force alarm clear 1/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66178

6TANV57CLI-35A

2-161

Total Access/NetVanta Carrier CLI Dictionary

force alarm reset <shelf/slot>


Usetheforcealarmreset<shelf/slot>commandtoclearallalarmsfromtheselectedalarmlog.

Usage Examples
Thefollowingisanexampleofhowtousetheforcealarmreset<shelf/slot>command.
#force alarm reset 1/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66183

2-162

6TANV57CLI-35A

Section 2, Commands - Common Commands

force alarm resync <shelf/slot>


Usetheforcealarmresync<shelf/slot>commandtoresynchronizethealarmsbetweenthe
controllerandthespecifiedshelf/slot.

Usage Examples
Thefollowingisanexampleofhowtousetheforcealarmresync<shelf/slot>command.
#force alarm resync 1/1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66185

6TANV57CLI-35A

2-163

Total Access/NetVanta Carrier CLI Dictionary

force auto-upgrade [abort|reset-config-cache|start]


Usetheforceautoupgrade[abort|resetconfigcache|start]commandtomanuallycontrol
autoupgradeoperations.

Syntax Description
abort

Abortautoupgradeofthesystem

resetconfigcache

Resetautoupgradeconfig(AUC)cache

start

Startautoupgradeofthesystem

Usage Examples
Thefollowingisanexampleofhowtousetheforceautoupgrade[abort|resetconfig
cache|start]command.
#force auto-upgrade abort
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66263

2-164

6TANV57CLI-35A

Section 2, Commands - Common Commands

force export [diagnostics|system-event-log]


Usetheforceexport[diagnostics|systemeventlog]commandtomanuallyexportdiagnostics
resultsorsystemeventlogentries.

Syntax Description
diagnostics

Senddiagnosticsresultstothefileserver

systemeventlog

Sendsystemeventlogtoeventlogexporthost

Usage Examples
Thefollowingisanexampleofhowtousetheforceexport[diagnostics|systemeventlog]
command.
#force export diagnostics
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63466

6TANV57CLI-35A

2-165

Total Access/NetVanta Carrier CLI Dictionary

force export diagnostics <shelf/slot/port>


Usetheforceexportdiagnostics<shelf/slot>commandtomanuallyexportdiagnosticsresults
forthespecifiedslot.

Usage Examples
Thefollowingisanexampleofhowtousetheforceexportdiagnostics<shelf/slot/port>
command.
#force export diagnostics 1/0
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
95548

2-166

6TANV57CLI-35A

Section 2, Commands - Common Commands

force export system-event-log new-events


Usetheforceexportsystemeventlogneweventscommandtomanuallyexporteventlog
entriesthatoccurredsincethelastexport.

Usage Examples
Thefollowingisanexampleofhowtousetheforceexportsystemeventlognewevents
command.
#force export system-event-log new-events
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87115

6TANV57CLI-35A

2-167

Total Access/NetVanta Carrier CLI Dictionary

force export system-event-log to syslog


Usetheforceexportsystemeventlogtosyslogcommandtoexportthesystemeventlogto
theprovisioningsyslogservers.

Usage Examples
Thefollowingisanexampleofhowtousetheforceexportsystemeventlogtosyslog
command.
#force export system-event-log to syslog
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63469

2-168

6TANV57CLI-35A

Section 2, Commands - Common Commands

force logoff <1-n>


Usetheforcelogoff<1n>commandtoterminateausersession.

Usage Examples
Thefollowingisanexampleofhowtousetheforcelogoff<1n>command.
#force logoff 2
#

Functional Notes
Usetheshowuserscommandtolookuptheindex(Numcolumn)fortheusersession.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83718

6TANV57CLI-35A

2-169

Total Access/NetVanta Carrier CLI Dictionary

force manual-switch erps east <shelf/slot/id>


Usetheforcemanualswitcherpseast<shelf/slot/id>commandtosetthemanualswitchinthe
selectedeastringdirection.

Usage Examples
Thefollowingisanexampleofhowtousetheforcemanualswitcherpseast<shelf/slot/id>
command.
#force manual-switch erps east 1/0/4
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
82099

2-170

6TANV57CLI-35A

Section 2, Commands - Common Commands

force manual-switch erps west <shelf/slot/id>


Usetheforcemanualswitcherpswest<shelf/slot/id>commandtosetthemanualswitchin
theselectedwestringdirection.

Usage Examples
Thefollowingisanexampleofhowtousetheforcemanualswitcherpswest<shelf/slot/id>
command.
#force manual-switch erps west 1/0/4
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
82098

6TANV57CLI-35A

2-171

Total Access/NetVanta Carrier CLI Dictionary

force manual-switch protection-group <shelf/slot>


Usetheforcemanualswitchprotectiongroup<shelf/slot>commandtoswitchprotection
fromaspecifiedmoduletotheEFMprotectmodule.Issuethesamecommandagaintotoggle
backtonoprotection.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
58711

2-172

6TANV57CLI-35A

Section 2, Commands - Common Commands

force manual-switch redundancy <shelf/slot>


Usetheforcemanualswitchredundancy<shelf/slot>commandtomanuallyforcearedun
dancyfailoveronthespecifiedactivemodule.

Usage Examples
Thefollowingisanexampleofhowtousetheforcemanualswitchredundancy<shelf/slot>
command.
#force manual-switch redundancy 1/A
#

Functional Notes
Forcingaswitchdisruptsservice.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46344

6TANV57CLI-35A

2-173

Total Access/NetVanta Carrier CLI Dictionary

force manual-switch system-timing <shelf>


Usetheforcemanualswitchsystemtiming<shelf>commandtomanuallyswitchtheactive
timingsourceonthespecifiedshelf.

Usage Examples
Thefollowingisanexampleofhowtousetheforcemanualswitchsystemtiming<shelf>
command.
#force manual-switch system-timing 1
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46172

2-174

6TANV57CLI-35A

Section 2, Commands - Common Commands

force peer default ip dhcp-client release interface ppp-group


<shelf/slot/group>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104332

6TANV57CLI-35A

2-175

Total Access/NetVanta Carrier CLI Dictionary

force peer default ip dhcp-client renew interface ppp-group


<shelf/slot/group>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104336

2-176

6TANV57CLI-35A

Section 2, Commands - Common Commands

force remote-download <remote-index> [application|boot]


Syntax Description
application

Applicationcode

boot

Bootcode

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133163

6TANV57CLI-35A

2-177

Total Access/NetVanta Carrier CLI Dictionary

force restart ez-provisioning


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
139884

2-178

6TANV57CLI-35A

Section 2, Commands - Common Commands

force retrain [fast|full]


Usetheforceretrain[full|fast]commandtoinitiateafullorfastretrainrequestforthe
selectedphysicalinterface/port.Environmentalcharacteristicssuchasimpedance,noise,oscil
latorfrequencies,orinterferencecanchangeovertimethatdegradetheperformanceofa
physicalinterface.Aretrainisareinitializationsequencespecifiedbythephysicalinterface
modulationstandardtoadapttochanginglineconditions.Aretrainmayalsobeusedtore
synchronizethedatapathofatransmitterreceiverpair.

Syntax Description
fast

Performafastretrain

full

Performafullretrain

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2Splitter
AM(1187125L1),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
20445

6TANV57CLI-35A

2-179

Total Access/NetVanta Carrier CLI Dictionary

force retrain fast [<shelf/slot/port>|<shelf/slot>]


Usetheforceretrainfast<shelf/slot/port>commandtoperformafastretrainonthespecified
interface/port.Afastretrainisashortenedinitializationsequencespecifiedbysomeofthe
modulationstandardstoquicklyadapttochanginglineconditionsandminimizelinedown
time.Fastretrainsmaynotbeabletoadapttoallchangedlineconditionsandfailurescan
occur.

Usage Examples
Thefollowingisanexampleofhowtousetheforceretrainfast[<shelf/slot/port>|<shelf/slot>]
command.
>force retrain fast 1/19/1
>

Functional Notes
Iffastretrainoptionisnotavailableforthecurrentmodulationorafailureduringfastretrain
occurs,afullretrainisinitiatedautomaticallyinstead.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2Splitter
AM(1187125L1),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
77861

2-180

6TANV57CLI-35A

Section 2, Commands - Common Commands

force retrain full [<shelf/slot/port>|<shelf/slot>]


Usetheforceretrainfull<shelf/slot/port>commandtoperformafullretrainonthespecified
interface/port.Afullretrainisequivalenttothenormalreinitializationsequencespecifiedby
amodulationstandardtooptimallyadapttochanginglineconditionsandmaximizeperfor
mance.

Usage Examples
Thefollowingisanexampleofhowtousetheforceretrainfull[<shelf/slot/port>|<shelf/slot>]
command.
>force retrain full 1/19/1
>

Functional Notes
Fullretrainscontinueuntilasuccessfulreinitializationiscompleted.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2Splitter
AM(1187125L1),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
77860

6TANV57CLI-35A

2-181

Total Access/NetVanta Carrier CLI Dictionary

force scr [all|modules]


Usetheforcescr[all|modules]commandtorebootmodulesusingthesystemcontrolled
rebootfeature.

Syntax Description
all

PerformawarmrestartofallmodulesandcontrollerusingSCR

modules

PerformawarmrestartofallmodulesusingSCR

Usage Examples
Thefollowingisanexampleofhowtousetheforcescr[all|modules]command.
#force scr all
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
89437

2-182

6TANV57CLI-35A

Section 2, Commands - Common Commands

force sip registration


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95878

6TANV57CLI-35A

2-183

Total Access/NetVanta Carrier CLI Dictionary

force sip registration <shelf/slot>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
133794

2-184

6TANV57CLI-35A

Section 2, Commands - Common Commands

force sip registration <shelf/slot> <Txx>


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
133795

6TANV57CLI-35A

2-185

Total Access/NetVanta Carrier CLI Dictionary

force sip registration <shelf/slot> <Txx> WORD


Syntax Description
<shelf/slot>

Specifiedslot

<Txx>

Trunkidentifier

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
133796

2-186

6TANV57CLI-35A

Section 2, Commands - Common Commands

force ssh-keys
Usetheforcesshkeyscommandtoforcethegenerationofnewsecureshell(SSH)keys.

Usage Examples
Thefollowingisanexampleofhowtousetheforcesshkeyscommand.
#force ssh-keys
Key generation in progress. The background task to generate new keys may
take 1
to 20 minutes

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87724

6TANV57CLI-35A

2-187

Total Access/NetVanta Carrier CLI Dictionary

logout
Usethelogoutcommandtoterminatethecurrentsessionandreturntotheloginscreen.

Usage Examples
Thefollowingisanexampleofhowtousethelogoutcommand.
>logout
Session now available
Press RETURN to get started.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),E1CEM32PortAM(1188801G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
16027

2-188

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping A.B.C.D
UsethepingA.B.C.DcommandtoverifyInternetProtocol(IP)networkconnectivity.Theping
commandhelpsdiagnosebasicIPnetworkconnectivitybyrepeatedlybouncingInternet
ControlMessageProtocol(ICMP)EchoRequestpacketsoffasystemusingaspecifiedIP
address.

Usage Examples
ThefollowingisanexampleofhowtousethepingA.B.C.Dcommand.
#PING 10.44.4.74
Pinging 10.44.4.74:
Press ^C to Cancel
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Ping statistics for 10.44.4.74:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42947

6TANV57CLI-35A

2-189

Total Access/NetVanta Carrier CLI Dictionary

ping A.B.C.D repeat <1-1000000>


UsethepingA.B.C.Drepeat<11000000>commandtoverifyInternetProtocol(IP)network
connectivity.ThepingcommandhelpsdiagnosebasicIPnetworkconnectivitybyrepeatedly
bouncingInternetControlMessageProtocol(ICMP)EchoRequestpacketsoffasystemusing
aspecifiedIPaddress.

Syntax Description
A.B.C.D

IPAddress

Usage Examples
ThefollowingisanexampleofhowtousethepingA.B.C.Drepeat<11000000>command.
#PING 10.44.4.74 repeat 6
Pinging 10.44.4.74:
Press ^C to Cancel
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Ping statistics for 10.44.4.74:
Packets: Sent = 6, Received = 6, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
#

Functional Notes
Usethe<11000000>inputtospecifyhowmanyICMPmessagesaresentpriortoterminating
thecommand.Thevalidrangefortherepeatcountis11000000.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP

2-190

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42948

6TANV57CLI-35A

2-191

Total Access/NetVanta Carrier CLI Dictionary

ping A.B.C.D repeat <1-1000000> timeout <1000-8000>


UsethepingA.B.C.Drepeat<11000000>timeout<10008000>commandtoverifyInternet
Protocol(IP)networkconnectivity.ThepingcommandhelpsdiagnosebasicIPnetwork
connectivitybyrepeatedlybouncingInternetControlMessageProtocol(ICMP)EchoRequest
packetsoffasystemusingaspecifiedIPaddress.

Syntax Description
A.B.C.D

IPAddress

<11000000>

RepeatCount

Usage Examples
ThefollowingisanexampleofhowtousethepingA.B.C.Drepeat<11000000>timeout
<10008000>command.
#PING 10.44.4.75 repeat 6 timeout 5000
Pinging 10.44.4.75:
Press ^C to Cancel
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for 10.44.4.75:
Packets: Sent = 6, Received = 0, Lost = 6 (100% loss),
Approximate round trip times in milli-seconds:
Minimum = N/A, Maximum = N/A, Average = N/A
#

Functional Notes
Usethe<11000000>inputtospecifyhowmanyICMPmessagesaresentpriortoterminating
thecommand.Thevalidrangefortherepeatcountis11000000.
Usethe<10008000>inputtospecifyhowlonginmillisecondstowaitbeforedeclaringa
responseastimedout.Thevalidrangeforthetimeoutis10008000milliseconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

2-192

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42949

6TANV57CLI-35A

2-193

Total Access/NetVanta Carrier CLI Dictionary

ping A.B.C.D repeat <1-1000000> timeout <1000-8000> size


<0-1448>
UsethepingA.B.C.Drepeat<11000000>timeout<10008000>size<01448>commandto
verifyInternetProtocol(IP)networkconnectivity.ThepingcommandhelpsdiagnosebasicIP
networkconnectivitybyrepeatedlybouncingInternetControlMessageProtocol(ICMP)Echo
RequestpacketsoffasystemusingaspecifiedIPaddress.

Syntax Description
A.B.C.D

IPAddress

<11000000>

RepeatCount

<10008000>

Timeoutinmilliseconds

Usage Examples
ThefollowingisanexampleofhowtousethepingA.B.C.Drepeat<11000000>timeout
<10008000>size<01448>command.
#PING 10.44.4.74 repeat 6 timeout 5000 size 1448
Pinging 10.44.4.74:
Press ^C to Cancel
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Reply from 10.44.4.74: time=1ms
Ping statistics for 10.44.4.74:
Packets: Sent = 6, Received = 6, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 1ms, Maximum = 1ms, Average = 1ms
#

Functional Notes
Usethe<11000000>inputtospecifyhowmanyICMPmessagesaresentpriortoterminating
thecommand.Thevalidrangefortherepeatcountis11000000.
Usethe<10008000>inputtospecifyhowlonginmillisecondstowaitbeforedeclaringa
responseastimedout.Thevalidrangeforthetimeoutis10008000milliseconds.
Usethe<01448>inputtospecifyhowlargetheICMPdatabufferis.Thevalidrangeforthe
sizeis01448bytes.

2-194

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42950

6TANV57CLI-35A

2-195

Total Access/NetVanta Carrier CLI Dictionary

ping atm <shelf/slot/port.sub>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
94229

2-196

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping atm <shelf/slot/port.sub> count <1-1000000>


Syntax Description
<shelf/slot/port.sub>

Enterportandsubinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
94231

6TANV57CLI-35A

2-197

Total Access/NetVanta Carrier CLI Dictionary

ping atm <shelf/slot/port.sub> count <1-1000000> destinationllid HEX:32 source-llid HEX:32


Syntax Description
<shelf/slot/port.sub>

Enterportandsubinterface

<11000000>

Numberofcells

HEX:32

LLID(32HEXDigits)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
94239

2-198

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>commandtodefine
themaintenancedomain,maintenanceassociation,andMEPIDforthesourceMEP.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100
#

Functional Notes
ThevalidrangefortheMEPIDis18191.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35188

6TANV57CLI-35A

2-199

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
commandtodefinethemaintenancedomain,maintenanceassociation,andMEPIDforthe
sourceMEPandthenumberofLBMmessagestobesent.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
#

Functional Notes
Usethe<18191>inputtospecifytheMEPID.ThevalidrangefortheMEPIDis18191.
Usethe<11024>inputtospecifythenumberofLBMmessagestobesent.Thevalidrangefor
themessagesis11024.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

2-200

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
35190

6TANV57CLI-35A

2-201

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>commandtotransmitloopbackmessages(LBM)tothetargetMEPorMIPto
testreachability.Definethemaintenancedomain,maintenanceassociation,MEPIDforthe
sourceMEP,thenumberofLBMmessagestobesent,andthe802.1pprioritybitstobesentin
theLBMmessage.WhentargetinganMEP,aMACaddressorMEPIDisused;however,when
targetinganMIP,aMACaddressisrequired.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4
#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.
ThevalidrangefortheLBMmessagessentis1to1024.
Thevalidrangeforthe802.1pprioritybitssentinLBMmessagesis0to7.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834

2-202

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35192

6TANV57CLI-35A

2-203

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>commandtodefinethemaintenancedomain,maintenance
association,andMEPIDforthesourceMEP,thenumberofLBMmessagestobesent,the
802.1pprioritybitstobesentintheLBMmessage,andthesize(inbytes)oftheLBM
messages.Thepingethernetcommandisusedtotransmitloopbackmessages(LBM)tothe
targetMEPorMIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEPID
canbeused;however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512
#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.
ThevalidrangeforthenumberofLBMmessagestobesentis1to1024.
Thevalidrangeforthe802.1pprioritybitstobesentintheLBMmessagesis0to7.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

2-204

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35194

6TANV57CLI-35A

2-205

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>commandtodefinethemaintenance
domain,maintenanceassociation,andMEPIDforthesourceMEP,thenumberofLBM
messagestobesent,the802.1pprioritybitstobesentintheLBMmessage,thesize(inbytes)
oftheLBMmessages,andthetime(inmilliseconds)towaitforaresponsetotheLBMsent.
Thepingethernetcommandisusedtotransmitloopbackmessages(LBM)tothetargetMEP
orMIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEPIDcanbeused;
however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000
#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.
ThevalidrangeforthenumberofLBMmessagestobesentis1to1024.
Thevalidrangeforthe802.1pprioritybitstobesentintheLBMmessagesis0to7.

Local Security Permissions


Admin,TechSupport

2-206

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35196

6TANV57CLI-35A

2-207

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000>
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>commandtodefine
themaintenancedomain,maintenanceassociation,andMEPIDforthesourceMEP,the
numberofLBMmessagestobesent,the802.1pprioritybitstobesentintheLBMmessage,
thesize(inbytes)oftheLBMmessages,thetime(inmilliseconds)towaitforaresponsetothe
LBMsent,andthetimebetween(inmilliseconds)thetransmissionofLBMmessages.The
pingethernetcommandisusedtotransmitloopbackmessages(LBM)tothetargetMEPor
MIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEPIDcanbeused;
however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>interval<1005000>command.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000 interval 2000
#

Functional Notes
UsethefirstWORDinputtodefinethemaintenancedomain.
UsethesecondWORDinputtodefinethemaintenanceassociation.
Usethe<18191>inputtodefinetheMEPIDforthesourceMEP.ThevalidrangefortheMEP
IDis1to8191.
Usethe<11024>inputtodefinethenumberofLBMmessagestobesent.Thevalidrangefor
thenumberofLBMmessagestobesentis1to1024.

2-208

6TANV57CLI-35A

Section 2, Commands - Common Commands

Usethe<07>inputtodefinethe802.1pprioritybitstobesentintheLBMmessage.Thevalid
rangefortheprioritybitsis0to7.
Usethe<461500>inputtodefinethesize(inbytes)oftheLBMmessages.Thevalidrangefor
thesizeis46to1500bytes.
Usethe<100060000>inputtodefinethetime(inmilliseconds)towaitforaresponsetothe
LBMsent.Thevalidrangeforthetimeoutis1000to60000milliseconds.
Usethe<1005000>inputtodefinethetimebetween(inmilliseconds)thetransmissionofLBM
messages.Thevalidrangefortheintervalis100to5000milliseconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35198

6TANV57CLI-35A

2-209

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORD[drop
eligible|validatedata|verbose]commandtodefinethemaintenancedomain,maintenance
association,andMEPIDforthesourceMEP,thenumberofLBMmessagestobesent,the
802.1pprioritybitstobesentintheLBMmessage,thesize(inbytes)oftheLBMmessages,the
time(inmilliseconds)towaitforaresponsetotheLBMsent,thetimebetween(inmilli
seconds)thetransmissionofLBMmessages,andthedatapatterntobesentintheLBMdata
payload.Thepingethernetcommandisusedtotransmitloopbackmessages(LBM)tothe
targetMEPorMIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEPID
canbeused;however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>interval<1005000>dataWORDcommand.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000 interval 2000 data ABCD
#

Functional Notes
UsethefirstWORDinputtodefinethemaintenancedomain.
UsethesecondWORDinputtodefinethemaintenanceassociation.

2-210

6TANV57CLI-35A

Section 2, Commands - Common Commands

Usethe<18191>inputtodefinetheMEPIDforthesourceMEP.ThevalidrangefortheMEP
IDis1to8191.
Usethe<11024>inputtodefinethenumberofLBMmessagestobesent.Thevalidrangefor
thenumberofLBMmessagestobesentis1to1024.
Usethe<07>inputtodefinethe802.1pprioritybitstobesentintheLBMmessage.Thevalid
rangefortheprioritybitsis0to7.
Usethe<461500>inputtodefinethesize(inbytes)oftheLBMmessages.Thevalidrangefor
thesizeis46to1500bytes.
Usethe<100060000>inputtodefinethetime(inmilliseconds)towaitforaresponsetothe
LBMsent.Thevalidrangeforthetimeoutis1000to60000milliseconds.
Usethe<1005000>inputtodefinethetimebetween(inmilliseconds)thetransmissionofLBM
messages.Thevalidrangefortheintervalis100to5000milliseconds.
UsethelastWORDinputtodefinethedatapatterntobesentintheLBMdatapayload.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35200

6TANV57CLI-35A

2-211

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligible[validatedata|verbose]commandtosetthedropeligiblebitintheVLANtag.The
pingethernetcommandisusedtotransmitloopbackmessages(LBM)tothetargetMEPor
MIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEPIDcanbeused;
however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>interval<1005000>dataWORDdropeligiblecommand.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000 interval 2000 data ABCD drop-eligible
#

Functional Notes
UsethefirstWORDinputtodefinethemaintenancedomain.
UsethesecondWORDinputtodefinethemaintenanceassociation.
Usethe<18191>inputtodefinetheMEPIDforthesourceMEP.ThevalidrangefortheMEP
IDis1to8191.

2-212

6TANV57CLI-35A

Section 2, Commands - Common Commands

Usethe<11024>inputtodefinethenumberofLBMmessagestobesent.Thevalidrangefor
thenumberofLBMmessagestobesentis1to1024.
Usethe<07>inputtodefinethe802.1pprioritybitstobesentintheLBMmessage.Thevalid
rangefortheprioritybitsis0to7.
Usethe<461500>inputtodefinethesize(inbytes)oftheLBMmessages.Thevalidrangefor
thesizeis46to1500bytes.
Usethe<100060000>inputtodefinethetime(inmilliseconds)towaitforaresponsetothe
LBMsent.Thevalidrangeforthetimeoutis1000to60000milliseconds.
Usethe<1005000>inputtodefinethetimebetween(inmilliseconds)thetransmissionofLBM
messages.Thevalidrangefortheintervalis100to5000milliseconds.
UsethelastWORDinputtodefinethedatapatterntobesentintheLBMdatapayload.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35201

6TANV57CLI-35A

2-213

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible validate-data
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35202

2-214

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible validate-data verbose
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDdrop
eligiblevalidatedataverbosecommandtosetthedropeligiblebitintheVLANtag,forcethe
transmittingMEPtovalidatethecontentsofthedatapayload,anddisplaytheresultsin
verboseformat.Thepingethernetcommandisusedtotransmitloopbackmessages(LBM)to
thetargetMEPorMIPtotestforreachability.WhentargetingaMEP,aMACaddressorMEP
IDcanbeused;however,whentargetingaMIP,aMACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>interval<1005000>dataWORDdropeligiblevalidatedataverbosecommand.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000 interval 2000 data ABCD drop-eligible
validation verbose
#

Functional Notes
UsethefirstWORDinputtodefinethemaintenancedomain.
UsethesecondWORDinputtodefinethemaintenanceassociation.

6TANV57CLI-35A

2-215

Total Access/NetVanta Carrier CLI Dictionary

Usethe<18191>inputtodefinetheMEPIDforthesourceMEP.ThevalidrangefortheMEP
IDis1to8191.
Usethe<11024>inputtodefinethenumberofLBMmessagestobesent.Thevalidrangefor
thenumberofLBMmessagestobesentis1to1024.
Usethe<07>inputtodefinethe802.1pprioritybitstobesentintheLBMmessage.Thevalid
rangefortheprioritybitsis0to7.
Usethe<461500>inputtodefinethesize(inbytes)oftheLBMmessages.Thevalidrangefor
thesizeis46to1500bytes.
Usethe<100060000>inputtodefinethetime(inmilliseconds)towaitforaresponsetothe
LBMsent.Thevalidrangeforthetimeoutis1000to60000milliseconds.
Usethe<1005000>inputtodefinethetimebetween(inmilliseconds)thetransmissionofLBM
messages.Thevalidrangefortheintervalis100to5000milliseconds.
UsethelastWORDinputtodefinethedatapatterntobesentintheLBMdatapayload.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35203

2-216

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD drop-eligible verbose
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35204

6TANV57CLI-35A

2-217

Total Access/NetVanta Carrier CLI Dictionary

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD validate-data
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35205

2-218

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD validate-data verbose
Usethepingethernetxx:xx:xx:xx:xx:xxsourceWORDWORD<18191>count<11024>
priority<07>size<461500>timeout<100060000>interval<1005000>dataWORDvalidate
dataverbosecommandtoforcethetransmittingMEPtovalidatethecontentsofthedata
payloadanddisplaytheresultsinverboseformat.Thepingethernetcommandisusedto
transmitloopbackmessages(LBM)tothetargetMEPorMIPtotestforreachability.When
targetingaMEP,aMACaddressorMEPIDcanbeused;however,whentargetingaMIP,a
MACaddressmustbeused.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Usage Examples
Thefollowingisanexampleofhowtousethepingethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>count<11024>priority<07>size<461500>timeout<1000
60000>interval<1005000>dataWORDvalidatedataverbosecommand.
#ping ethernet 00:A0:C8:05:03:00 source myDom myAssoc 100 count 10
priority 4 size 512 timeout 20000 interval 2000 data ABCD validation
verbose
#

Functional Notes
UsethefirstWORDinputtodefinethemaintenancedomain.
UsethesecondWORDinputtodefinethemaintenanceassociation.

6TANV57CLI-35A

2-219

Total Access/NetVanta Carrier CLI Dictionary

Usethe<18191>inputtodefinetheMEPIDforthesourceMEP.ThevalidrangefortheMEP
IDis1to8191.
Usethe<11024>inputtodefinethenumberofLBMmessagestobesent.Thevalidrangefor
thenumberofLBMmessagestobesentis1to1024.
Usethe<07>inputtodefinethe802.1pprioritybitstobesentintheLBMmessage.Thevalid
rangefortheprioritybitsis0to7.
Usethe<461500>inputtodefinethesize(inbytes)oftheLBMmessages.Thevalidrangefor
thesizeis46to1500bytes.
Usethe<100060000>inputtodefinethetime(inmilliseconds)towaitforaresponsetothe
LBMsent.Thevalidrangeforthetimeoutis1000to60000milliseconds.
Usethe<1005000>inputtodefinethetimebetween(inmilliseconds)thetransmissionofLBM
messages.Thevalidrangefortheintervalis100to5000milliseconds.
UsethelastWORDinputtodefinethedatapatterntobesentintheLBMdatapayload.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35206

2-220

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source WORD


WORD <1-8191> count <1-1024> priority <0-7> size <461500> timeout <1000-60000> interval <100-5000> data
WORD verbose
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

Sourcemaintenancedomain

WORD

Sourcemaintenanceassociation

<18191>

SourceMEPID

<11024>

Numberofmessages

<07>

802.1pPriorityBitSetting

<461500>

Sizeinbytes

<100060000>

Timeinmilliseconds

<1005000>

Timeinmilliseconds

WORD

FillpatternfordataTLV(repeatedtomeettotalsize)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35207

6TANV57CLI-35A

2-221

Total Access/NetVanta Carrier CLI Dictionary

ping ip-host WORD <shelf/slot> A.B.C.D


UsethepingA.B.C.DcommandtoverifyInternetProtocol(IP)networkconnectivity.Theping
commandhelpsdiagnosebasicIPnetworkconnectivitybyrepeatedlybouncingInternet
ControlMessageProtocol(ICMP)EchoRequestpacketsoffasystemusingaspecifiedIP
address.

Syntax Description
WORD

NameofIPHost

<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111667

2-222

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000>


UsethepingA.B.C.Drepeat<11000000>commandtoverifyInternetProtocol(IP)network
connectivity.ThepingcommandhelpsdiagnosebasicIPnetworkconnectivitybyrepeatedly
bouncingInternetControlMessageProtocol(ICMP)EchoRequestpacketsoffasystemusing
aspecifiedIPaddress.

Syntax Description
WORD

NameofIPHost

<shelf/slot>

Specifiedslot

A.B.C.D

IPAddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111669

6TANV57CLI-35A

2-223

Total Access/NetVanta Carrier CLI Dictionary

ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000>


timeout <1000-5000>
UsethepingA.B.C.Drepeat<11000000>timeout<10008000>commandtoverifyInternet
Protocol(IP)networkconnectivity.ThepingcommandhelpsdiagnosebasicIPnetwork
connectivitybyrepeatedlybouncingInternetControlMessageProtocol(ICMP)EchoRequest
packetsoffasystemusingaspecifiedIPaddress.

Syntax Description
WORD

NameofIPHost

<shelf/slot>

Specifiedslot

A.B.C.D

IPAddress

<11000000>

RepeatCount

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111671

2-224

6TANV57CLI-35A

Section 2, Commands - Common Commands

ping ip-host WORD <shelf/slot> A.B.C.D repeat <1-1000000>


timeout <1000-5000> size <0-1448>
UsethepingA.B.C.Drepeat<11000000>timeout<10008000>size<01448>commandto
verifyInternetProtocol(IP)networkconnectivity.ThepingcommandhelpsdiagnosebasicIP
networkconnectivitybyrepeatedlybouncingInternetControlMessageProtocol(ICMP)Echo
RequestpacketsoffasystemusingaspecifiedIPaddress.

Syntax Description
WORD

NameofIPHost

<shelf/slot>

Specifiedslot

A.B.C.D

IPAddress

<11000000>

RepeatCount

<10005000>

Timeoutinmilliseconds

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111673

6TANV57CLI-35A

2-225

Total Access/NetVanta Carrier CLI Dictionary

prompt-detail
Thisallowsthefullpromptdetailtobeused.Usethenoformofthiscommandtoremovethe
detailfromthepromptanddisplayonlytheminimumprompt.Defaultisfullpromptdetail.

Usage Examples
Thefollowingisanexampleofhowtousethepromptdetailcommand.
TA5K(config-shdsl 1/8/1)#do no prompt-detail
(shdsl)#do prompt-detail
TA5K(config-shdsl 1/8/1)#

Functional Notes
Thisenablesthefullpromptdetail.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
131370

2-226

6TANV57CLI-35A

Section 2, Commands - Common Commands

reload
Usethereloadcommandtoperformarestartofthefirmwareimmediately.

Usage Examples
Thefollowingisanexampleofhowtousethereloadcommand.
#reload
Save System Configuration?[y/n]y
You are about to reboot the system. Continue?[y/n]y

Functional Notes
Performingareloaddisruptsdatatraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-227

Total Access/NetVanta Carrier CLI Dictionary

Command ID
46774

2-228

6TANV57CLI-35A

Section 2, Commands - Common Commands

reload [<shelf/slot>|<remote-index>]
Usethereload<shelf/slot>commandtoperformamanualreloadofthesystemontheselected
slot.

Usage Examples
Thefollowingisanexampleofhowtousethereload[<shelf/slot>|<remoteindex>]command.
#reload 1/1
You are about to reboot the selected module(s). Continue?[y/n]y

Functional Notes
Performingareloaddisruptsdatatraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
46978

6TANV57CLI-35A

2-229

Total Access/NetVanta Carrier CLI Dictionary

show [aaa|alarm|arp|clock|default-config|door|dynamiccounter|evc|evc-map|event-log|ezprovisioning|flash|interfaces|mevc|outputerrors|policer|protection-group|runningconfig|shaper|shdsl|sntp|startup-config|system|systemmanagement-evc|system-timing|temperaturesensor|users|version|vlan]
Usetheshowcommandtodisplaystatusandconfigurationinformationfortheselected
option.

Syntax Description

2-230

aaa

ShowAuthenticationAuthorizationandAccountingcounters

alarm

Displaysystemalarmstatus

arp

DisplaytheAddressResolutionProtocoltableandtimeout

clock

Displaysystemclockinformation

defaultconfig

Defaultconfiguration

door

Displaystatusofalldoors

dynamiccounter

Displayalldynamiccounters

evc

DisplayallcreatedEVCs

evcmap

DisplayallcreatedEVCmaps

eventlog

Displayssystemeventlogforallevents

ezprovisioning

EZProvisioning

flash

Listfilesinflash

interfaces

Displayallinterfaces

mevc

DisplayallcreatedMuxponderEthernetVirtualConnections

outputerrors

Errorsoutputduringlastapplicationofaconfigurationfile

policer

Displayallcreatedpolicers

protectiongroup

Showallprotectiongroups

runningconfig

Showallcurrentnondefaultrunningconfiguration

shaper

Displayallcreatedshapers

shdsl

ShowglobalSHDSLsettings

sntp

DisplaySNTPstatus

6TANV57CLI-35A

Section 2, Commands - Common Commands

startupconfig

Startupconfiguration

system

Displayscurrentsysteminformation

systemmanagementevc

DisplayinformationforthesystemmanagementEVC

systemtiming

Displaytiminginformation

temperaturesensor

Displaystatusofalltemperaturesensors

users

Displayalistofconnectionsanduserscurrentlyloggedin

version

Systemversionandinventoryinformation

vlan

Displaycurrentvirtuallocalareanetworkinformation

Usage Examples
Thefollowingisasampleoutputoftheshow[aaa|alarm|arp|clock|default
config|door|dynamiccounter|evc|evcmap|eventlog|ezprovisioning|flash|inter
faces|mevc|outputerrors|policer|protectiongroup|running
config|shaper|shdsl|sntp|startupconfig|system|systemmanagementevc|system
timing|temperaturesensor|users|version|vlan]command.
! Example of show aaa
#show aaa
Authentication

Authorization

Accounting

Packets sent:

Invalid responses:

Timeouts:

Requests Accepted:

Requests Denied:

#
! Example of show clock
#show clock
11/10/2008 13:40:13
Uptime is 5 minutes
#
! Example of show dynamic-counter
#show dynamic-counter
Counter| Type |
Rate (kbps)

Port/Queue

Bytes

Packets

| Avg

-------|-------|-----------------|----------------|----------------|---------------

6TANV57CLI-35A

1/0/1

|NONE

|NONE

|0

|0

|0

1/0/2

|NONE

|NONE

|0

|0

|0

1/0/3

|NONE

|NONE

|0

|0

|0

1/0/4

|NONE

|NONE

|0

|0

|0

2-231

Total Access/NetVanta Carrier CLI Dictionary

1/0/5

|NONE

|NONE

|0

|0

|0

1/0/6

|NONE

|NONE

|0

|0

|0

1/0/7

|NONE

|NONE

|0

|0

|0

1/0/8

|NONE

|NONE

|0

|0

|0

#
! Example of show evc
#show evc
All EVC Tags Available in MEN
Tag
--

Name

State

Status

example_evc

Disabled Disabled

Attributes:
CE-VLAN Preservation: Enabled
MEN Port: Invalid
#
! Example of show evc-map
#show evc-map
Name

State

Status

example-evc-map

Disabled Disabled

Match Criteria

Destination

UNI: Invalid

EVC: Not Defined

Untagged /

MEN-PRI: Inherit

Priority Tagged only: Disabled

MEN-QUEUE: Inherit
Policer: None

#
! Example of show interfaces
#show interfaces
SHDSL 1/0/1

IfId = 1

Description

SHDSL Port #1

....
#
! Example of show policer
#show policer
Name

State

example

Disabled Disabled

Status

Attributes:
CIR: 0 kbps
EIR: No Limit

2-232

6TANV57CLI-35A

Section 2, Commands - Common Commands

CBS: 3125 bytes


EBS: 12500 bytes
Mode: Not Applied
WARNING: NO MAPS CONNECTED
#
! Example of show shdsl
#show shdsl
SHDSL Mode

: LTU w/o Handshake

SHDSL Training Timeout : 60 seconds


#
! Example of show system-management-evc
#show system-management-evc
Tag

Name

State

Status

99

System-Management-EVC

Enabled

Running

Attributes:
MEN Port

: Ethernet 1/0/1

IP

: 10.44.3.209

Subnet

: 255.255.0.0

MEN Priority: 7
#
! Example of show temperature-sensor
#show temperature-sensor
Internal Temperature
Current

: 29.60C / 85.28F

Maximum

: 29.76C / 85.57F

Threshold : 65.00C / 149.00F


#
! Example of show users
#show users
Username
ADMIN

Connecti Type
Craft

CLI

From
--

Login Time
11/10/08 13:38:29

#
! Example of show version
#show version

6TANV57CLI-35A

2-233

Total Access/NetVanta Carrier CLI Dictionary

ADTRAN NetVanta838
App Code Version

: B01.11

App Code Checksum : 1213A7B9


Boot Code Version : A01
Boot Code Checksum: 02EF9501
Part Number

: E1200633G4

CLEI Code

: SIM5K10BRA

Serial Number

: H23A4234

MAC Address

: 00:A0:C8:28:DD:DC

Product Revision

: A

System Release

: 4.1

Build Number

: 04.01.00.50

Functional Notes
UsetheaaaoptiontodisplaystatusandcountersfortheAuthentication,Authorization,and
Accounting(AAA)system.
Usetheclockoptiontodisplaythesystemtimeanddate.
Usethedooroptiontodisplaythestatusofanyaccessdoorsonthesystem.
Usethedynamiccounteroptiontodisplaythecountersandstatusofalldynamiccountersin
thesystem.
UsetheevcoptiontodisplaydetailedstatusandconfigurationinformationforallEVCs.The
outputalsoincludesapoolofEVCsthatcanbeusedifthisissupportedbyaconnected
device.
UsetheevcmapoptiontodisplaythecurrentconfigurationandstatusofallEVCmapsinthe
system.
Usetheinterfacesoptiontodisplaythecurrentstatusandcountersforallinterfacesinthe
system.
Usethepoliceroptiontodisplaythecurrentconfigurationandstatusforallpolicersinthe
system.
UsetherunningconfigoptiontodisplaytheCLIcommandsrequiredtoconfigureafactory
defaultedsystemtomatchthecurrentrunningbehavior.
UsetheshdsloptiontodisplaysystemlevelSHDSLparameters.
Usethesystemmanagementevcoptiontodisplaythecurrentstatusandconfigurationofthe
systemmanagementEVC.
Usethetemperaturesensoroptiontodisplaythecurrentstatusofalltemperaturesensorsin
thesystem.
Usetheusersoptiontodisplayalistofuserscurrentlyloggedintothesystem.
Usetheversionoptiontodisplaythecurrentunitinventoryinformation.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-234

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1),
RPOTSAM(1187150L1),GPONAM(1187501G1),VDSL2SplitterAM(1187125L1),E1CEM
32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),
QuadGigELM(1187550E1),QuadGigELM(1187551E1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),TA5000
23inchFan(1187080L1),SM10GE(1187025G2),NV814(1200637G4),NV818(1200637G2),
NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40993

6TANV57CLI-35A

2-235

Total Access/NetVanta Carrier CLI Dictionary

show aaa [local|radius|tacacs+]


Usetheshowaaa[local|radius|tacacs+]commandtodisplaystatusandcountersforthe
specifiedAuthentication,Authorization,andAccounting(AAA)subsystem.

Syntax Description
aaa

ShowAuthenticationAuthorizationandAccountingcounters

local

ShowonlyAAAcountersforLocaloperations

radius

ShowonlyAAAcountersforRADIUSoperations

tacacs+

ShowonlyAAAcountersforTACACS+operations

Usage Examples
Thefollowingisasampleoutputoftheshowaaa[local|radius|tacacs+]command.
#show aaa radius
Authentication
Packets sent:

Invalid responses:

Timeouts:

Requests Accepted:

Requests Denied:

Challenges:

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77373

2-236

6TANV57CLI-35A

Section 2, Commands - Common Commands

show alarm log [<shelf/slot>|ascending|descending]


Usetheshowalarmlog[<shelf/slot>|ascending|descending]commandtodisplaytheentries
foraspecifiedshelfandslotorallentriesinthecurrentlocalalarmlogintheselectedorder.

Syntax Description
log

Historicalalarminformationfortheshelf

<shelf/slot>

Historicalalarminformationforthespecifiedslot

ascending

Forceascendingchronology

descending

Forcedescendingchronology

Usage Examples
Thefollowingisasampleoutputoftheshowalarmlog[<shelf/slot>|ascending|descending]
command.
#show alarm log
Alarm Log - Master Alarms
Date
Status

Time

Port

Level

41 Alarms
Description

------------------------------------------------------------------------------11/10/08 14:21:07
*Event

EQPT

Minor

Power Up

11/10/08 14:21:08
*Active

ENV

Minor

PWR A Fail

11/10/08 14:21:15
*Active

ETH #1

Major

Link Down

Functional Notes
Itemsmarkedwithanasterik(*)havenotbeenacknowledgedwiththeforcealarm
acknowledgecommand.Itemsthatarehighlightedarecurrentlyactive.Thosethatarenot
highlightedhaveeitherclearedorareeventsandmayberemovedfromthealarmlogwiththe
forcealarmclearcommand.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-237

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46993

2-238

6TANV57CLI-35A

Section 2, Commands - Common Commands

show alarm log <shelf/slot> [ascending|descending]


Usetheshowalarmlog<shelf/slot>[ascending|descending]commandtodisplayallentriesin
thealarmlogforthespecifiedmoduleineitherascendingordescendingorder.

Syntax Description
<shelf/slot>

Historicalalarminformationforthespecifiedslot

ascending

Forceascendingchronology

descending

Forcedescendingchronology

Usage Examples
Thefollowingisasampleoutputoftheshowalarmlog<shelf/slot>[ascending|descending]
command.
#show alarm log 1/0 descending
Alarm Log - Master Alarms
Date
Status

Time

Port

Level

4 Alarms
Description

------------------------------------------------------------------------------11/10/08 14:21:15
Active

ETH #4

Major

Link Down

11/10/08 14:21:15
Active

ETH #3

Major

Link Down

11/10/08 14:21:15
Active

ETH #2

Major

Link Down

11/10/08 14:21:08
Active

ENV

Minor

PWR A Fail

Functional Notes
Itemsmarkedwithanasterisk(*)havenotbeenacknowledgedwiththeforcealarm
acknowledgecommand.Itemsthatarehighlightedarecurrentlyactive.Thosethatarenot
highlightedhaveeitherclearedorareeventsandmayberemovedfromthealarmlogwiththe
forcealarmclearcommand.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-239

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46994

2-240

6TANV57CLI-35A

Section 2, Commands - Common Commands

show arp <shelf/slot>


Usetheshowarp<shelf/slot>commandtodisplaytheAddressResolutionProtocol(ARP)
tableandtimeout.

Usage Examples
Thefollowingisasampleoutputoftheshowarp<shelf/slot>command.
#show arp
ADDRESS TTL(min) MAC ADDRESS INTERFACE TYPE
10.22.18.3 19 00:E0:29:6C:BA:31 eth 0/1 Dynamic
192.168.20.2 16 00:A0:C8:0D:E9:AD eth 0/2 Dynamic
224.0.0.5 20 01:00:5E:00:00:05 eth 0/2 Permanent
#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
89498

6TANV57CLI-35A

2-241

Total Access/NetVanta Carrier CLI Dictionary

show auto-upgrade module-status <shelf/slot>


Usetheshowautoupgrademodulestatus<shelf/slot>commandtodisplaytheautoupgrade
statusofthespecifiedshelf/slot.

Usage Examples
Thefollowingisasampleoutputoftheshowautoupgrademodulestatus<shelf/slot>
command.
#show auto-upgrade module-status 1/1
Slot (1

, 00:00:00): Idle, 1187180L1 (D10.152)

Upgrades: 0/0, Errors: 0/0, Found: 3, Deferred: 0, Needed: 0, Active: 0


System(

00:00:00): Idle

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77824

2-242

6TANV57CLI-35A

Section 2, Commands - Common Commands

show auto-upgrade module-status <shelf/slot> realtime


Usetheshowautoupgrademodulestatus<shelf/slot>realtimecommandtodisplaytheauto
upgradestatusofthespecifiedshelf/slotwithcontinuousupdates.

Syntax Description
<shelf/slot>

Selectthemoduleforautoupgradestatus

Usage Examples
Thefollowingisasampleoutputoftheshowautoupgrademodulestatus<shelf/slot>
realtimecommand.
#show auto-upgrade module-status 1/1 realtime
------------------------------------------------------------------------------Slot (1

, 00:00:00): Idle, 1187180L1 (D10.152)

Upgrades: 0/0, Errors: 0/0, Found: 3, Deferred: 0, Needed: 0, Active: 0


System(

00:00:00): Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82908

6TANV57CLI-35A

2-243

Total Access/NetVanta Carrier CLI Dictionary

show auto-upgrade shelf-status [<shelf>|realtime]


Usetheshowautoupgradeshelfstatus[<shelf>|realtime]commandtodisplaytheauto
upgradestatusofthespecifiedshelf.

Syntax Description
shelfstatus

Displayautoupgradestatusforcurrentselectedshelf

<shelf>

Selecttheshelfforautoupgradestatus

realtime

Displayautoupgradestatusforcurrentselectedshelf

Usage Examples
Thefollowingisasampleoutputoftheshowautoupgradeshelfstatus[<shelf>|realtime]
command.
(config)#show auto-upgrade status
Slot (1/SCM, 00:00:00): Idle, 1187010L1 (C00.02)
Slot (1/4

, 00:00:00): Idle, 1187150L1 (D00.092)

Slot (1/8

, 00:00:00): Idle, 1187180L1 (D10.059)

Slot (1/10 , 00:00:00): Idle, 1187800L1 (D00.092)


Slot (1/14 , 00:00:00): Idle, 1187101L1 (A08.11)
Slot (1/21 , 00:00:00): Idle, 1187260G1 (D00.092)
Slot (1/A

, 00:00:00): Idle, 1187020L1 (D10.076)

Slot (2/12 , 00:00:00): Idle, 1187180L1 (D00.092)


Upgrades: 0/0, Errors: 0/0, Found: 8, Ignored: 0, Needed: 0, Active: 0
Shelf(

00:00:00): Warning, necessary provisions not set

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77825

2-244

6TANV57CLI-35A

Section 2, Commands - Common Commands

show auto-upgrade shelf-status <shelf> realtime


Usetheshowautoupgradeshelfstatus<shelf>realtimecommandtodisplaytheauto
upgradestatusofthespecifiedshelfwithcontinuousupdates.

Syntax Description
<shelf>

Selecttheshelfforautoupgradestatus

Usage Examples
Thefollowingisasampleoutputoftheshowautoupgradeshelfstatus<shelf>realtime
command.
#show auto-upgrade shelf-status 1 realtime
------------------------------------------------------------------------------Slot (SCM, 00:00:00): Idle, 1187010L1A (D00.72)
Slot (1

, 00:00:00): Idle, 1187180L1 (D10.152)

Slot (B

, 00:00:00): Idle, 1187020L1 (D10.153Z)

Upgrades: 0/0, Errors: 0/0, Found: 3, Deferred: 0, Needed: 0, Active: 0


System(

00:00:00): Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommand.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82909

6TANV57CLI-35A

2-245

Total Access/NetVanta Carrier CLI Dictionary

show clock detail


Usetheshowclockdetailcommandtodisplaythecurrentday,thecurrenttime,andthe
configurationoftheclock.

Usage Examples
Thefollowingisasampleoutputoftheshowclockdetailcommand.
#show clock detail
11/10/2008 14:27:07
Uptime is 6 minutes
Clock Source = Local
Time Zone = GMT, Time Zone Offset = 0 hours, 0 minutes
#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43754

2-246

6TANV57CLI-35A

Section 2, Commands - Common Commands

show copy file-server flash [<shelf/slot>|<remote-index>]


Usetheshowcopyfileserverflash<shelf/slot>commandtodisplaythestatusofafirmware
updatetothespecifiedshelf/slot.

Usage Examples
Thefollowingisasampleoutputoftheshowcopyfileserverflash[<shelf/slot>|<remote
index>]command.
#show copy file-server flash 1/s
Idle
#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),SCM(1188010E1),SCM
(1187010L1),SCMG2(1187010G2)

Command ID
87739

6TANV57CLI-35A

2-247

Total Access/NetVanta Carrier CLI Dictionary

show copy file-server flash [<shelf/slot>|<remote-index>]


realtime
Usetheshowcopyfileserverflash<shelf/slot>realtimecommandtodisplaythestatusofa
firmwareupdatetothespecifiedshelf/slotwithcontinuousupdates.

Syntax Description
<shelf/slot>

Displaycopystatusforspecfiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Usage Examples
Thefollowingisasampleoutputoftheshowcopyfileserverflash[<shelf/slot>|<remote
index>]realtimecommand.
#show copy file-server flash 1/s realtim
------------------------------------------------------------------------------Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommand.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),SCM(1188010E1),SCM
(1187010L1),SCMG2(1187010G2)

2-248

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
87741

6TANV57CLI-35A

2-249

Total Access/NetVanta Carrier CLI Dictionary

show dynamic-counter <shelf/slot/index>


Usetheshowdynamiccounter<shelf/slot/index>commandtodisplaythecountsforall
dynamiccountersoraspecifieddynamiccounter.

Usage Examples
Thefollowingisasampleoutputoftheshowdynamiccounter<shelf/slot/index>command.
#show dynamic-counter 1/0/1
Counter| Type |
Rate (kbps)

Port/Queue

Bytes

Packets

| Avg

-------|-------|-----------------|----------------|----------------|--------------1/0/1

|NONE

|NONE

|0

|0

|0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46053

2-250

6TANV57CLI-35A

Section 2, Commands - Common Commands

show efm-group [<shelf/slot>|<shelf>]


Usetheshowefmgroup<shelf/slot>commandtoshowalistofallEFMgroupsprovisioned
ontheselectedshelf/slot.

Usage Examples
Thefollowingisasampleoutputoftheshowefmgroup[<shelf/slot>|<shelf>]command.
#sho efm-group 1/18
Slot

Alias

UpRate DnRate MinAct

/Id
18/1

Links
TEST 1000

1000

Links

18/5

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
61915

6TANV57CLI-35A

2-251

Total Access/NetVanta Carrier CLI Dictionary

show efm-link [<shelf/slot>|<shelf>]


Usetheshowefmlink<shelf/slot>commandtoshowalistofallEFMlinksavailableonthe
selectedshelf/slot.

Usage Examples
Thefollowingisasampleoutputoftheshowefmlink[<shelf/slot>|<shelf>]command.
#sho efm-link 1/15
Slot

Port

Installed

Port Type

15

SHDSL

15

SHDSL

15

SHDSL

15

SHDSL

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
61872

2-252

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm [association|config-errors|defaultdomain|domain|stack|traceroute-cache]


Usetheshowethernetcfmcommandtoviewthecurrentstatusforallitemsassociatedwith
thespecifiedparameter.

Syntax Description
association

Displayinformationaboutallassociations

configerrors

Displayfullcontentsofconfigurationerrorlist

defaultdomain

Displaythecurrentvaluesforthedefaultmaintenancedomain
settings

domain

Displayinformationaboutalldomains

stack

DisplayfullcontentsoftheCFMstack

traceroutecache

Showalltracerouteentries

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfm[association|configerrors|default
domain|domain|stack|traceroutecache]command.
#show ethernet cfm association
Index 1 myDom/myAssoc
CCM Interval 1-second
MEP Database Rule: configured-only
Component
1

Primary VID
1000

MIP-mode
---

Sender-ID
Defer

MEP-Count
2

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),DS1PPPAM(1187803G2),E1INTLPPPAM
(1188803G2),CHDS3PPPAM(1187220G1),NV814(1200637G4),NV818(1200637G2),NV
824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838

6TANV57CLI-35A

2-253

Total Access/NetVanta Carrier CLI Dictionary

OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
34998

2-254

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm association [WORD|detail|incomplete]


Usetheshowethernetcfmassociation[WORD|detail|incomplete]commandtodisplaythe
maintenanceassociationsconfiguredonthesystem.

Syntax Description
association

Displayinformationaboutallassociations

WORD

Filterbycontainingmaintancedomain

detail

Displaysallinformation

incomplete

Displayallincompleteassociations

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmassociation[WORD|detail|incom
plete]command.
>show ethernet cfm association
Index 1 MD_1/MD_1_MA_1
CCM Interval 1s
Component Primary VID MIP-mode Sender-ID MEP-Count
1 1000 --- None 3
Index 2 MD_1/MD_1_MA_2
CCM Interval 1s
Component Primary VID MIP-mode Sender-ID MEP-Count
1 1001 --- None 2
Index 1 MD_2/MD_2_MA_1
CCM Interval 1s
Component Primary VID MIP-mode Sender-ID MEP-Count
1 1000 --- None 2
>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-255

Total Access/NetVanta Carrier CLI Dictionary

Command ID
35027

2-256

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm association WORD [WORD|detail]


UsetheshowethernetcfmassociationWORD[WORD|detail]commandtodisplaythe
maintenanceassociationsconfiguredonthespecifieddomain.

Syntax Description
WORD

Filterbycontainingmaintancedomain

WORD

Filterbyassociationname

detail

Displaysallinformation

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmassociationWORD[WORD|detail]
command.
>show ethernet cfm association MD_1 MD_1_MA_1 detail
Domain: MD_1
Assoc: MD_1_MA_1
Index: 1
CCM Interval: 1s
Component: 1
Primary VID: 1000
MIP-mode: --Sender-ID: None
MEP Count: 3
MEP List:
1000 (local)
>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-257

Total Access/NetVanta Carrier CLI Dictionary

Command ID
35028

2-258

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm association WORD WORD detail


UsetheshowethernetcfmassociationWORDWORDdetailcommandtodisplaythe
specifiedmaintenanceassociationconfiguredonthespecifieddomain.

Syntax Description
WORD

Filterbycontainingmaintancedomain

WORD

Filterbyassociationname

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmassociationWORDWORDdetail
command.
>show ethernet cfm association MD_1 MD_1_MA_1 detail
Domain: MD_1
Assoc: MD_1_MA_1
Index: 1
CCM Interval: 1s
Component: 1
Primary VID: 1000
MIP-mode: --Sender-ID: None
MEP Count: 3
MEP List:
1000 (local)
>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35032

6TANV57CLI-35A

2-259

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm config-errors interface efm-group <shelf/


slot/group>
Usetheshowethernetcfmconfigerrorsinterfaceefmgroup<shelf/slot/group>commandto
displaytheconfigurationerrorlistassociatedwiththeselectedEFMgroup.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmconfigerrorsinterfaceefmgroup
<shelf/slot/group>command.
#show ethernet cfm config-errors interface efm-group 1/0/1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35021

2-260

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm config-errors interface ethernet <shelf/slot/


port>
Usetheshowethernetcfmconfigerrorsinterfaceethernet<shelf/slot/port>commandto
displaytheconfigurationerrorlistassociatedwiththeselectedEthernetport.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmconfigerrorsinterfaceethernet
<shelf/slot/port>command.
#show ethernet cfm config-errors interface ethernet 1/0/1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
35017

6TANV57CLI-35A

2-261

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm config-errors interface gigabit-ethernet


<shelf/slot/port>
Usetheshowethernetcfmconfigerrorsinterfacegigabitethernet<shelf/slot/port>command
todisplaytheconfigurationerrorlistassociatedwiththeselectedGigabitEthernetport.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmconfigerrorsinterfacegigabit
ethernet<shelf/slot/port>command.
#show ethernet cfm config-errors interface gigabit-ethernet 1/0/1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
35019

2-262

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm config-errors vlan [<1-4094>|none]


Usetheshowethernetcfmconfigerrorsvlan[<14094|none]commandtodisplaytheconfig
urationerrorlistassociatedwiththeselectedVLAN.

Syntax Description
<14094>

EnterVLANID

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmconfigerrorsvlan[<14094>|none]
command.
#show ethernet cfm config-errors vlan 1000.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
35013

6TANV57CLI-35A

2-263

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm default-domain component-id <1-n>


Usetheshowethernetcfmdefaultdomaincomponentid<1n>commandtodisplaythe
defaultdomainsettingsforallVLANentriesinthecomponententered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmdefaultdomaincomponentid<1
n>command.
>show ethernet cfm default-domain component-id 1
mip-level-default

: 5

mip-allowed-default

: none

mip-sender-id-default : chassis
Component 1:
Vlan

Level

MIP-mode

Sender-ID

Status

----------------------------------------------------99

-1

1000

2000

-1

4000

defer

defer

true

any

chassis

true

defer

defer

true

any

defer

true

>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78009

2-264

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm default-domain component-id <1-n> vlan


<1-4094>
Usetheshowethernetcfmdefaultdomaincomponentid<1n>vlan<14094>commandto
displaythedefaultdomainsettingsfortheenteredVLANentryinthecomponentspecified.

Syntax Description
<1n>

EntercomponentID

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmdefaultdomaincomponentid<1
n>vlan<14094>command.
>show ethernet cfm default-domain component-id 1 vlan 1000
mip-level-default

: 5

mip-allowed-default

: none

mip-sender-id-default : chassis
Component 1:
Vlan

Level

MIP-mode

Sender-ID

Status

----------------------------------------------------1000

any

chassis

true

>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78011

6TANV57CLI-35A

2-265

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm default-domain vlan <1-4094>


Usetheshowethernetcfmdefaultdomainvlan<14094>commandtodisplaythedefault
domainsettingsfortheenteredVLANentryacrossallcomponentsthatareconfiguredtouse
thatVLAN.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmdefaultdomainvlan<14094>
command.
>show ethernet cfm default-domain vlan 1000
mip-level-default

: 5

mip-allowed-default

: none

mip-sender-id-default : chassis
Component 1:
Vlan

Level

MIP-mode

Sender-ID

Status

----------------------------------------------------1000

any

chassis

true

Functional Notes
Only1componentinthebridgeissupportedforSR4.1.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78014

2-266

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm domain [WORD|detail|incomplete]


Usetheshowethernetcfmdomain[WORD|detail|incomplete]commandtodisplaythe
maintenancedomainsconfiguredonthesystem.

Syntax Description
domain

Displayinformationaboutalldomains

WORD

Filterbymaintenancedomainname

detail

Displayallinformation

incomplete

Displayincompletedomains

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmdomain[WORD|detail|incom
plete]command.
>show ethernet cfm domain
Index Domain Name
Lvl MIP-mode Sender-ID Assoc Count
1 MD_1
1 None 2
2 MD_2
2 None 1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35022

6TANV57CLI-35A

2-267

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm domain WORD detail


UsetheshowethernetcfmdomainWORDdetailcommandtodisplaytheselectedmainte
nancedomainindetailedformat.

Syntax Description
WORD

Filterbymaintenancedomainname

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmdomainWORDdetailcommand.
#show ethernet cfm domain MD_1 detail
Domain Name: MD_1
Index: 1
Level: 1
MIP-Mode: --Sender-ID: None
Remote MEP Hold Time: 100
Association Count: 2
MD_1_MA_1
MD_1_MA_2

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35026

2-268

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep [local|remote]


Usetheshowethernetcfmmep[local|remote]commandtodisplaythemaintenanceassoci
ationendpoints(MEPs)configuredonthesystem.

Syntax Description
local

DisplayallMEPsconfiguredonthissystem

remote

DisplayallMEPslocatedonothersystems

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmep[local|remote]command.
>show ethernet cfm mep remote
Local MEP 1001
Domain/Assoc: MD_1/MD_1_MA_1
Level: 1 VLAN: 1000
Interface: EFM-GROUP 1
Remote MEP database: Port Iface
MEPID State Age MAC RDI Status Status
1000 Fail 0d 00:18:29 00:A0:C8:05:03:00 True Up Up
1002 Fail 0d 02:30:14 FF:FF:FF:FF:FF:FF False No TLV No TLV

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35034

6TANV57CLI-35A

2-269

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local [detail|down|fault|statistics|up]


Usetheshowethernetcfmmeplocalcommandtodisplaythedetailed,fault,andstatistics
informationforallMEPs.

Syntax Description
local

DisplayallMEPsconfiguredonthissystem

detail

Showallinformation

down

OnlydisplaydownMEPs

fault

Showfaultinformation

statistics

Showstatistics

up

OnlydisplayupMEPs

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocal
[detail|down|fault|statistics|up]command.
>show ethernet cfm mep local detail
MEPs configured on this device:
MEP-ID: 2
Domain/Assoc: md1/assoc1
MAC Address: 00:A0:C8:05:04:60 Interface: GIG-ETH 1 Vlan: 0
Level: 2 Direction: Down Priority: 7
Admin State: Up CCM State: y
Fault Notification Settings for MEPID 2
Fault Alarms Sent to --Highest Allowed Defect: 3
AlarmTime: 2500 ResetTime: 2500

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838

2-270

6TANV57CLI-35A

Section 2, Commands - Common Commands

OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35035

6TANV57CLI-35A

2-271

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local association WORD


[detail|fault|statistics]
UsetheshowethernetcfmmeplocalassociationcommandtodisplaytheMEPsinaspecified
association.

Syntax Description
WORD

Enteranassociation

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmeplocalassociationWORD
[detail|fault|statistics]command.
>show ethernet cfm mep local association assoc1 detail
MEPs configured on this device:
MEP-ID: 2
Domain/Assoc: md1/assoc1
MAC Address: 00:A0:C8:05:04:60 Interface: GIG-ETH 1 Vlan: 0
Level: 2 Direction: Down Priority: 7
Admin State: Up CCM State: y
Fault Notification Settings for MEPID 2
Fault Alarms Sent to --Highest Allowed Defect: 3
AlarmTime: 2500 ResetTime: 2500
Current Fault State for MEPID 2
Fault State: Defect Reported
Last Reported Fault:
Current Highest Defect: RemoteCCM
Current Defects (highest to lowest defect priority):
Remote CCM: MEP 2
Last Errored CCM:
Last Cross Connect CCM:
Message Statistics for MEPID 2
CCMs Transmitted: 1392522CCMs Received Out of Sequence: 0
LBRs Transmitted: 0 Next LBM ID: 1
LBRs Received: 0 LBRs Received Out of Order: 0
LBRs with bad data: 0
Next LTM ID: 1 Unexpected LTRs: 0

2-272

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35050

6TANV57CLI-35A

2-273

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local domain WORD


[detail|fault|statistics]
UsetheshowethernetcfmmeplocaldomaincommandtodisplaytheMEPsinaspecified
domain.

Syntax Description
WORD

Enteradomain

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmeplocaldomainWORD
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local domain
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35040

2-274

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local down [detail|fault|statistics]


Usetheshowethernetcfmmeplocaldowncommandtodisplaythedetailed,fault,andsta
tisticsinformationfordownMEPs.

Syntax Description
down

OnlydisplaydownMEPs

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocaldown
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local down
detail - Displays detailed down MEP information
fault - Displays down MEP fault information
statistics - Displays down MEP statistics
NetVanta873>show ethernet cfm mep local down
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35059

6TANV57CLI-35A

2-275

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local interface efm-group [<shelf/slot/


port>|WORD]
Usetheshowethernetcfmmeplocalinterfaceefmgroup<shelf/slot/group>commandto
displaytheMEPsonthespecifiedinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalinterfaceefmgroup
[<shelf/slot/port>|WORD]command.
>show ethernet cfm mep local interface efm-group 1
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35080

2-276

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local interface efm-group [<shelf/slot/


port>|WORD] detail
Syntax Description
<shelf/slot/port>

Specifiedgroup

WORD

Specifiedinterfacebyalias

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35081

6TANV57CLI-35A

2-277

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local interface efm-group [<shelf/slot/


port>|WORD] fault
Syntax Description
<shelf/slot/port>

Specifiedgroup

WORD

Specifiedinterfacebyalias

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35083

2-278

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local interface efm-group [<shelf/slot/


port>|WORD] statistics
Syntax Description
<shelf/slot/port>

Specifiedgroup

WORD

Specifiedinterfacebyalias

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35082

6TANV57CLI-35A

2-279

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local interface ethernet <shelf/slot/


port> [detail|fault|statistics]
Usetheshowethernetcfmmeplocalinterfaceethernet<shelf/slot/port>commandtodisplay
theMEPsonthespecifiedinterface.

Syntax Description
<shelf/slot/port>

EnterEthernetportnumber

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalinterfaceethernet<shelf/
slot/port>[detail|fault|statistics]command.
>show ethernet cfm mep local interface ethernet 1
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35070

2-280

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local interface gigabit-ethernet <shelf/


slot/port> [detail|fault|statistics]
Usetheshowethernetcfmmeplocalinterfacegigabitethernet<shelf/slot/port>commandto
displaytheMEPsonthespecifiedinterface.

Syntax Description
<shelf/slot/port>

EnterGigabitEthernetportnumber

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalinterfacegigabitethernet
<shelf/slot/port>[detail|fault|statistics]command.
>show ethernet cfm mep local interface gigabit-ethernet 1
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35075

6TANV57CLI-35A

2-281

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local interface ppp-group <shelf/slot/


group> [detail|fault|statistics]
Usetheshowethernetcfmmeplocalinterfacepppgroup<shelf/slot/group>commandto
displaytheMEPsonthespecifiedinterface.

Syntax Description
<shelf/slot/group>

Specifiedgroup

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalinterfacepppgroup
<shelf/slot/group>[detail|fault|statistics]command.
>show ethernet cfm mep local interface gigabit-ethernet 1
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
96584

2-282

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local level <0-7> [detail|fault|statistics]


UsetheshowethernetcfmmeplocallevelcommandtodisplaytheMEPsataspecifiedlevel.

Syntax Description
<07>

Enteralevel

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocallevel<07>
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local level 2
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35045

6TANV57CLI-35A

2-283

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local mep-id <1-8191>


[detail|fault|statistics]
UsetheshowethernetcfmmeplocalmepidcommandtodisplayMEPswiththespeci
fiedMEPID.

Syntax Description
<18191>

EnterMEPID

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalmepid<18191>
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local mep-id 2
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35064

2-284

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local up [detail|fault|statistics]


Usetheshowethernetcfmmeplocalupcommandtodisplaythedetailed,fault,andstatistics
informationforupMEPs.

Syntax Description
up

OnlydisplayupMEPs

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
90021

6TANV57CLI-35A

2-285

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local vlan [<1-4094>|none]


UsetheshowethernetcfmmeplocalvlancommandtodisplaytheMEPsinaspecifiedVLAN.

Syntax Description
<14094>

EnteraVLANID

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalvlan[<14094>|none]
command.
NetVanta873>show ethernet cfm mep local vlan 100
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35054

2-286

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep local vlan <1-4094>


[detail|fault|statistics]
Usetheshowethernetcfmmeplocalvlan<14094>commandtodisplaytheMEPsina
specifiedVLAN.

Syntax Description
<14094>

EnteraVLANID

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalvlan<14094>
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local vlan 100
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35055

6TANV57CLI-35A

2-287

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep local vlan none [detail|fault|statistics]


UsetheshowethernetcfmmeplocalvlannonecommandtodisplaytheMEPsnotassociated
withaVLAN.

Syntax Description
none

NotassociatedwithanyVLAN

detail

Showallinformation

fault

Showfaultinformation

statistics

Showstatistics

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmeplocalvlannone
[detail|fault|statistics]command.
NetVanta873>show ethernet cfm mep local vlan none
MEPs configured on this device:
Level Domain/Association
Mepid Admin Iface VLAN Type MAC Send-CCM Highest-Err
Lvl 2 md1/assoc1
2 Up GIG-ETH 1 0 Down 00:A0:C8:05:04:60 y RemoteCCM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87626

2-288

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote [detail|down]


Usetheshowethernetcfmmepremote[detail|down]commandtodisplaythesummaryor
detailedinformationforallremoteMEPs.Ifnoargumentisusedthesummaryinformation
willbedisplayed.Ifthedownargumentisused,onlyinformationonremoteMEPsinlocal
downMEPdatabaseswillbeshown.

Syntax Description
remote

DisplayallMEPslocatedonothersystems

detail

ShowinformationlearnedfromremoteMEPsindetail

down

OnlydisplaydownMEPs

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremote[detail|down]
command.
>show ethernet cfm mep remote
Local MEP 500
Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Ok

00:A0:C8:35:58:7E

False Blocked

0d 04:41:24

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-289

Total Access/NetVanta Carrier CLI Dictionary

Command ID
35084

2-290

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote association WORD


UsetheshowethernetcfmmepremoteassociationWORDcommandtodisplaytheremote
MEPsinallassociationswhosenamematchesWORD.Therecanbeseveraldifferent
matchingMaintenanceAssociationswiththesamenameastheyareuniqueiftheyareina
differentMaintenanceDomain.

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmepremoteassociationWORD
command.
>show ethernet cfm mep remote association MA_3
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: EFM-GROUP 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

0d 05:06:02

00:A0:C8:2B:8B:EA

False No TLV

Up

302

Ok

0d 05:06:02

00:A0:C8:05:30:00

False No TLV

Up

Functional Notes
UsetheWORDinputtospecifythemaintenanceassociationname.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35093

6TANV57CLI-35A

2-291

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote association WORD detail


UsetheshowethernetcfmmepremoteassociationWORDdetailcommandtodisplaythe
remoteMEPsinaspecifiedassociationindetailedformat.

Syntax Description
WORD

Enterassociationname

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmepremoteassociationWORD
detailcommand.
>show ethernet cfm mep remote association MA_3 detail
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:07:57

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_3

Association:

MA_3

Remote MEPID:

302

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:07:59

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:05:30:00

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Functional Notes
UsetheWORDinputtospecifythemaintenanceassociationname.

2-292

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35094

6TANV57CLI-35A

2-293

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote domain WORD


UsetheshowethernetcfmmepremotedomainWORDcommandtodisplayalltheremote
MEPsinthedomainwhosenamematchesWORD.

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmepremotedomainWORD
command.
>show ethernet cfm mep remote domain MD_3
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: EFM-GROUP 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:10:35

Up

Functional Notes
UsetheWORDinputtospecifythemaintenancedomainname.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35087

2-294

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote domain WORD detail


UsetheshowethernetcfmmepremotedomainWORDcommandtodisplayalltheremote
MEPsinthedomainwhosenamematchesWORD.TheremoteMEPinformationisdisplayed
inthedetailedformat.

Syntax Description
WORD

ShowinformationlearnedfromremoteMEPsinspecified
domain

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmmepremotedomainWORDdetail
command.
>show ethernet cfm mep remote domain MD_3 detail
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:13:39

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Functional Notes
UsetheWORDinputtospecifythemaintenancedomainname.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838

6TANV57CLI-35A

2-295

Total Access/NetVanta Carrier CLI Dictionary

OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35088

2-296

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote down detail


Usetheshowethernetcfmmepremotedowndetailcommandtodisplaythedetailedinfor
mationforallremoteMEPsthataremembersofalocaldownMEPdatabase.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotedowndetail
command.
>show ethernet cfm mep remote down detail
Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Ok

Age:

0d 04:30:08

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35099

6TANV57CLI-35A

2-297

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface efm-group [<shelf/


slot/port>|WORD]
Usetheshowethernetcfmmepremoteinterfaceefmgroup<shelf/slot/group>commandto
displaytheremoteMEPsinalocalMEPdatabaseforalllocalMEPsthatareconfiguredonthe
interface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfaceefmgroup
[<shelf/slot/port>|WORD]command.
>show ethernet cfm mep remote interface efm-group 1/0/1
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: EFM-GROUP 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:17:10

Up

Local MEP 500


Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: EFM-GROUP 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Fail

00:A0:C8:35:58:7E

False Blocked

0d 04:56:27

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

2-298

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
35111

6TANV57CLI-35A

2-299

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface efm-group [<shelf/


slot/port>|WORD] detail
Usetheshowethernetcfmmepremoteinterfaceefmgroup<shelf/slot/group>detail
commandtodisplaythedetailedinformationonremoteMEPsinalocalMEPdatabaseforall
localMEPsthatareconfiguredontheinterface.

Syntax Description
<shelf/slot/port>

Specifiedgroup

WORD

Specifiedinterfacebyalias

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfaceefmgroup
[<shelf/slot/port>|WORD]detailcommand.
>show ethernet cfm mep remote interface efm-group 1/0/1 detail

2-300

Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:18:26

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 04:57:42

Vlan:

1000

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35112

6TANV57CLI-35A

2-301

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface ethernet <shelf/slot/


port>
Usetheshowethernetcfmmepremoteinterfaceethernet<shelf/slot/group>commandto
displaytheremoteMEPsinalocalMEPdatabaseforalllocalMEPsthatareconfiguredonthe
interface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfaceethernet
<shelf/slot/port>command.
>show ethernet cfm mep remote interface ethernet 1/0/1
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:19:45

Up

Local MEP 500


Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Fail

00:A0:C8:35:58:7E

False Blocked

0d 04:59:02

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

2-302

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
35105

6TANV57CLI-35A

2-303

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface ethernet <shelf/slot/


port> detail
Usetheshowethernetcfmmepremoteinterfaceethernet<shelf/slot/group>detailcommand
todisplaythedetailedinformationonremoteMEPsinalocalMEPdatabaseforalllocalMEPs
thatareconfiguredontheinterface.

Syntax Description
<shelf/slot/port>

Specifyethernetinterface

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfaceethernet
<shelf/slot/port>detailcommand.
>show ethernet cfm mep remote interface ethernet 1/0/1 detail
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:20:51

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:00:07

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-304

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35106

6TANV57CLI-35A

2-305

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface gigabit-ethernet


<shelf/slot/port>
Usetheshowethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/group>
commandtodisplaytheremoteMEPsinalocalMEPdatabaseforalllocalMEPsthatare
configuredontheinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfacegigabit
ethernet<shelf/slot/port>command.
>show ethernet cfm mep remote interface gigabit-ethernet 1/0/1
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: GIG-ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:23:22

Up

Local MEP 500


Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: GIG-ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Fail

00:A0:C8:35:58:7E

False Blocked

0d 05:02:39

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

2-306

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
35108

6TANV57CLI-35A

2-307

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface gigabit-ethernet


<shelf/slot/port> detail
Usetheshowethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/group>detail
commandtodisplaythedetailedinformationonremoteMEPsinalocalMEPdatabaseforall
localMEPsthatareconfiguredontheinterface.

Syntax Description
<shelf/slot/port>

Specifygigabitethernetinterface

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfacegigabit
ethernet<shelf/slot/port>detailcommand.
>show ethernet cfm mep remote interface ethernet 1 deta
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:24:18

Vlan:

1000

Ingress Interface:

GIG-ETH 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:03:34

Vlan:

1000

Ingress Interface:

GIG-ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-308

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35109

6TANV57CLI-35A

2-309

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote interface ppp-group <shelf/


slot/group>
Usetheshowethernetcfmmepremoteinterfacepppgroup<shelf/slot/group>commandto
displaytheremoteMEPsinalocalMEPdatabaseforalllocalMEPsthatareconfiguredonthe
interface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfacepppgroup
<shelf/slot/group>command.
>show ethernet cfm mep remote interface gigabit-ethernet 1/0/1
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: GIG-ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:23:22

Up

Local MEP 500


Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: GIG-ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Fail

00:A0:C8:35:58:7E

False Blocked

0d 05:02:39

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
96589

2-310

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote interface ppp-group <shelf/


slot/group> detail
Usetheshowethernetcfmmepremoteinterfacegigabitethernet<shelf/slot/group>detail
commandtodisplaythedetailedinformationonremoteMEPsinalocalMEPdatabaseforall
localMEPsthatareconfiguredontheinterface.

Syntax Description
<shelf/slot/group>

Specifiedgroup

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteinterfacepppgroup
<shelf/slot/group>detailcommand.
>show ethernet cfm mep remote interface ethernet 1 deta
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:24:18

Vlan:

1000

Ingress Interface:

GIG-ETH 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:03:34

Vlan:

1000

Ingress Interface:

GIG-ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-311

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
96590

2-312

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote level <0-7>


UsetheshowethernetcfmmepremotelevelcommandtodisplaytheremoteMEPsata
specifiedlevel.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotelevel<07>command.
>show ethernet cfm mep remote level 5
Local MEP 500
Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Fail

00:A0:C8:35:58:7E

False Blocked

0d 05:05:42

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35090

6TANV57CLI-35A

2-313

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote level <0-7> detail


UsetheshowethernetcfmmepremotelevelcommandtodisplaytheremoteMEPsata
specifiedlevelinthedetailedformat.

Syntax Description
<07>

Enterlevel

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotelevel<07>detail
command.
>show ethernet cfm mep remote level 3 detail
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:26:56

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35091

2-314

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote local-mep <1-8191>


Usetheshowethernetcfmmepremotelocalmep<18191>commandtolimittheoutput
displaytoremoteMEPsintheMEPdatabasesoflocalMEPsmatchingtheMEPIDentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotelocalmep<18191>
command.
>show ethernet cfm mep remote local 300
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

00:A0:C8:2B:8B:EA

False No TLV

0d 05:29:07

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35101

6TANV57CLI-35A

2-315

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote local-mep <1-8191> detail


Usetheshowethernetcfmmepremotelocalmep<18191>detailcommandtolimitthe
outputdisplaytoremoteMEPsintheMEPdatabasesoflocalMEPsmatchingtheMEPID
entered.DisplaytheremoteMEPinformationinthedetailedformat.

Syntax Description
<18191>

EnterMEPID

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotelocalmep<18191>
detailcommand.
>show ethernet cfm mep remote local 500 detail
Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:09:11

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35102

2-316

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote remote-mep <1-8191>


UsetheshowethernetcfmmepremoteremotemepcommandtodisplayremoteMEPswith
thespecifiedMEPID.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteremotemep<18191>
command.
>show ethernet cfm mep remote remote-mep 501
Local MEP 500
Domain/Assoc: MD_5/MA_5
Level: 5

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

501

Ok

00:A0:C8:35:58:7E

False Blocked

0d 04:24:45

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35114

6TANV57CLI-35A

2-317

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote remote-mep <1-8191> detail


Usetheshowethernetcfmmepremoteremotemep<18191>detailcommandtodisplayin
thedetailedformatremoteMEPswiththespecifiedMEPID.

Syntax Description
<18191>

EnterMEPID

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremoteremotemep<18191>
detailcommand.
>show ethernet cfm mep remote remote 501 detail
Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:10:35

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35115

2-318

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm mep remote vlan [<1-4094>|none]


Usetheshowethernetcfmmepremotevlan[<14094>|none]commandtodisplaytheremote
MEPsintheMEPdatabasesoflocalMEPsoperatingonthespecifiedVLAN

Syntax Description
<14094>

EnterVLANID

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotevlan[<14094>|none]
command.
>show ethernet cfm mep remote vlan 1000
Local MEP 300
Domain/Assoc: MD_3/MA_3
Level: 3

VLAN: 1000

Interface: ETH 1
MEP Database Rule: configured-only
Remote MEP database

Port

Iface

Status

Status

MEPID

State Age

MAC

RDI

301

Ok

2d 16:20:49

00:A0:C8:2B:8B:EA

False No

302

Ok

2d 16:18:27

00:A0:C8:35:58:7E

False Blocked

Up

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35095

6TANV57CLI-35A

2-319

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote vlan <1-4094> detail


Usetheshowethernetcfmmepremotevlan<14094>detailcommandtodisplaytheremote
MEPsinaspecifiedVLAN.Theresultsaredisplayedinthedetailedformat.

Syntax Description
<14094>

EnterVLANID

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotevlan<14094>detail
command.
>show ethernet cfm mep remote vlan 1000 detail
Domain:

MD_3

Association:

MA_3

Remote MEPID:

301

Entry in DB of Local MEPID:

300

State:

Ok

Age:

0d 05:35:22

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:2B:8B:EA

RDI:

False

Port Status:

No TLV

Interface Status:

Up

Sender-ID:

None

Domain:

MD_5

Association:

MA_5

Remote MEPID:

501

Entry in DB of Local MEPID:

500

State:

Fail

Age:

0d 05:14:38

Vlan:

1000

Ingress Interface:

ETH 1

MAC:

00:A0:C8:35:58:7E

RDI:

False

Port Status:

Blocked

Interface Status:

Up

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-320

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35097

6TANV57CLI-35A

2-321

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm mep remote vlan none detail


Usetheshowethernetcfmmepremotevlannonedetailcommandtodisplaytheremote
MEPsintheMEPdatabasesoflocalMEPsoperatingwithoutastagareshowninthedetailed
format.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmmepremotevlannonedetail
command.
>show ethernet cfm mep remote vlan none detail
Domain:

MD_4

Association:

MA_4

Remote MEPID:

401

Entry in DB of Local MEPID:

400

State:

Ok

Age:

11d 00:14:19

Vlan:

Ingress Interface:

EFM-GROUP 1

MAC:

00:A0:C8:05:30:01

RDI:

False

Port Status:

No TLV

Interface Status:

No TLV

Sender-ID:

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87631

2-322

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm stack down


UsetheshowethernetcfmstackdowncommandtodisplaythedownMEPsthatareinthe
CFMstack.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackdowncommand.
>show ethernet cfm stack down
Interface

Vlan Lvl Type

Dir MEPID MAC Address

Domain/Assoc.

-----------------------------------------------------------------------------giga-eth 1/B/1

1000

MEP

dwn

301 00:A0:C8:2B:8B:EA MD_3/MA_3

giga-eth 1/B/1

1000

MEP

dwn

401 00:A0:C8:2B:8B:EA MD_4/MA_4

giga-eth 1/B/1

1000

MIP

n/a

n/a 00:A0:C8:2B:8B:EA n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35011

6TANV57CLI-35A

2-323

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm stack interface efm-group <shelf/slot/


group>
UsetheshowethernetcfmstackinterfaceefmgroupcommandtodisplaytheMEPsthatare
intheCFMstackandontheinterfaceentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackinterfaceefmgroup<shelf/
slot/group>command.
>show ethernet cfm stack interface efm-group 1/0/1
Interface

Vlan

Lvl

Type

Dir

MEPID MAC

Domain/Association
EFM-GROUP 1

1000

MEP

dwn

300

00:A0:C8:05:03:00

MD_3/MA_3

Interface

Vlan

Lvl

Type

Dir

MEPID MAC

Domain/Association
EFM-GROUP 1

1000

MEP

dwn

500

00:A0:C8:05:03:00

MD_5/MA_5

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35006

2-324

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm stack interface ethernet <shelf/slot/port>


UsetheshowethernetcfmstackinterfaceethernetcommandtodisplaytheMEPsthatarein
theCFMstackandontheinterfaceentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackinterfaceethernet<shelf/slot/
port>command.
>show ethernet cfm stack interface ethernet 1/0/1
Interface

Vlan

Lvl

Type

Dir

MEPID MAC

MEP

dwn

300

Type

Dir

MEPID MAC

dwn

500

Domain/Association
ETH 1

1000

00:A0:C8:05:03:00

MD_3/MA_3

Interface

Vlan

Lvl

Domain/Association
ETH 1

1000

MEP

00:A0:C8:05:03:00

MD_5/MA_5

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
35002

6TANV57CLI-35A

2-325

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm stack interface gigabit-ethernet <shelf/slot/


port>
UsetheshowethernetcfmstackinterfacegigabitethernetcommandtodisplaytheMEPsand
MIPsthatareintheCFMstackandontheinterfaceentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackinterfacegigabitethernet
<shelf/slot/port>command.
#show ethernet cfm stack interface gigabit-ethernet 1/B/1
Interface

Vlan Lvl Type

Dir MEPID MAC Address

Domain/Assoc.

-----------------------------------------------------------------------------giga-eth 1/B/1

1000

MEP

dwn

301 00:A0:C8:2B:8B:EA MD_3/MA_3

giga-eth 1/B/1

1000

MEP

dwn

401 00:A0:C8:2B:8B:EA MD_4/MA_4

giga-eth 1/B/1

1000

MIP

n/a

n/a 00:A0:C8:2B:8B:EA n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35004

2-326

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm stack interface ppp-group <shelf/slot/


group>
UsetheshowethernetcfmstackinterfacepppgroupcommandtodisplaytheMEPsandMIPs
thatareintheCFMstackandontheinterfaceentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackinterfacepppgroup<shelf/
slot/group>command.
#show ethernet cfm stack interface gigabit-ethernet 1/B/1
Interface

Vlan Lvl Type

Dir MEPID MAC Address

Domain/Assoc.

-----------------------------------------------------------------------------giga-eth 1/B/1

1000

MEP

dwn

301 00:A0:C8:2B:8B:EA MD_3/MA_3

giga-eth 1/B/1

1000

MEP

dwn

401 00:A0:C8:2B:8B:EA MD_4/MA_4

giga-eth 1/B/1

1000

MIP

n/a

n/a 00:A0:C8:2B:8B:EA n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
96582

6TANV57CLI-35A

2-327

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm stack level <0-7>


Usetheshowethernetcfmstacklevel<07>commandtodisplaytheMEPsandMIPsthatare
intheCFMstackandatthelevelentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstacklevel<07>command.
>show ethernet cfm stack level 4
Interface

Vlan Lvl Type

Dir MEPID MAC Address

Domain/Assoc.

-----------------------------------------------------------------------------giga-eth 1/B/1

1000

MEP

dwn

401 00:A0:C8:2B:8B:EA MD_4/MA_4

giga-eth 1/B/1

1001

MIP

n/a

n/a 00:A0:C8:2B:8B:EA n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35010

2-328

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm stack vlan [<1-4094>|none]


Usetheshowethernetcfmstacklevel[<14094>|none]commandtodisplaytheMEPsand
MIPsthatareintheCFMstackandontheVLANentered.

Syntax Description
<14094>

DisplayspecifiedVLAN

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmstackvlan[<14094>|none]
command.
>show ethernet cfm stack vlan 1000
Interface

Vlan Lvl Type

Dir MEPID MAC Address

Domain/Assoc.

-----------------------------------------------------------------------------giga-eth 1/B/1

1000

MEP

dwn

301 00:A0:C8:2B:8B:EA MD_3/MA_3

giga-eth 1/B/1

1000

MEP

dwn

401 00:A0:C8:2B:8B:EA MD_4/MA_4

giga-eth 1/B/1

1000

MIP

n/a

n/a 00:A0:C8:2B:8B:EA n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35007

6TANV57CLI-35A

2-329

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm traceroute-cache association WORD


UsetheshowethernetcfmtraceroutecacheassociationWORDcommandtoshowtraceroute
resultsoriginatingfromlocalMEPsinMaintenanceAssociationswhosenamesmatchWORD.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecacheassociation
WORDcommand.
#show ethernet cfm traceroute-cache association MA_3
Tracing route from MEP 300
-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35122

2-330

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm traceroute-cache domain WORD


UsetheshowethernetcfmtraceroutecachedomainWORDcommandtoshowtraceroute
resultsoriginatingfromlocalMEPsintheMaintenanceDomainswhosenamematches
WORD.

Usage Examples
ThefollowingisasampleoutputoftheshowethernetcfmtraceroutecachedomainWORD
command.
#show ethernet cfm traceroute-cache domain MD_3
Tracing route from MEP 300
-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35118

6TANV57CLI-35A

2-331

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm traceroute-cache interface efm-group


[<shelf/slot/group>|WORD]
Usetheshowethernetcfmtraceroutecacheinterfaceefmgroup<shelf/slot/port>commandto
showtracerouteresultsoriginatingfromlocalMEPsonthespecifiedinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecacheinterfaceefm
group[<shelf/slot/group>|WORD]command.
>show ethernet cfm traceroute-cache interface efm-group 1/0/1

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
35133

2-332

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm traceroute-cache interface ethernet <shelf/


slot/port>
Usetheshowethernetcfmtraceroutecacheinterfaceethernet<shelf/slot/port>commandto
showtracerouteresultsoriginatingfromlocalMEPsonthespecifiedinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecacheinterfaceethernet
<shelf/slot/port>command.
>show ethernet cfm traceroute-cache interface ethernet 1/0/1

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
35129

6TANV57CLI-35A

2-333

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm traceroute-cache interface gigabit-ethernet


<shelf/slot/port>
Usetheshowethernetcfmtraceroutecacheinterfacegigabitethernet<shelf/slot/port>
commandtoshowtracerouteresultsoriginatingfromlocalMEPsonthespecifiedinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecacheinterfacegigabit
ethernet<shelf/slot/port>command.
>show ethernet cfm traceroute-cache interface gigabit-ethernet 1/0/1

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

2-334

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
35131

6TANV57CLI-35A

2-335

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm traceroute-cache level <0-7>


Usetheshowethernetcfmtraceroutecachelevel<07>commandtoshowtracerouteresults
originatingfromlocalMEPsresidingatthelevelentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecachelevel<07>
command.
>show ethernet cfm traceroute-cache level 3

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35120

2-336

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet cfm traceroute-cache local-mep-id <1-8191>


Usetheshowethernetcfmtraceroutecachelocalmepid<18191>commandtoshow
tracerouteresultsoriginatingfromlocalMEPswithIDsmatchingtheMEPIDentered.

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecachelocalmepid<1
8191>command.
>show ethernet cfm traceroute-cache local-mep-id 300

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35126

6TANV57CLI-35A

2-337

Total Access/NetVanta Carrier CLI Dictionary

show ethernet cfm traceroute-cache vlan [<1-4094>|none]


Usetheshowethernetcfmtraceroutecachevlan[<14094>|none]commandtoshow
tracerouteresultsoriginatingfromlocalMEPsresidingontheVLANentered.

Syntax Description
<14094>

Specifyvlan

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisasampleoutputoftheshowethernetcfmtraceroutecachevlan[<1
4094>|none]command.
>show ethernet cfm traceroute-cache vlan 1000

Tracing route from MEP 300


-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

--------------------------------------------------------------------------------

00:A0:C8:2B:8B:EA

Term Mep -

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

giga-eth B/1

ingOk

egrNoTlv

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached
---

00:A0:C8:2B:8B:EA

Term Mep -

RLY_HIT

Destination reached

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834

2-338

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35123

6TANV57CLI-35A

2-339

Total Access/NetVanta Carrier CLI Dictionary

show ethernet evc-advertisement


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
109774

2-340

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet evc-advertisement interface [efmgroup|ethernet|gigabit-ethernet|muxponderhighspeed|muxponder-midspeed]


Syntax Description
efmgroup

ShowresultsofEVCAdvertisementforallEFMgroups

ethernet

ShowresultsofEVCAdvertisementforallEthernetports

gigabitethernet

ShowresultsofEVCAdvertisementforallGigabitEthernetports

muxponderhighspeed

ShowresultsofEVCAdvertisementforallMuxponder
Highspeedports

muxpondermidspeed

ShowresultsofEVCAdvertisementforallMuxponder
Midspeedports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
109775

6TANV57CLI-35A

2-341

Total Access/NetVanta Carrier CLI Dictionary

show ethernet evc-advertisement interface efm-group <shelf/


slot/group>
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
109778

2-342

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet evc-advertisement interface ethernet <shelf/


slot/port>
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
109780

6TANV57CLI-35A

2-343

Total Access/NetVanta Carrier CLI Dictionary

show ethernet evc-advertisement interface gigabit-ethernet


<shelf/slot/port>
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
109783

2-344

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ethernet evc-advertisement interface muxponderhighspeed <shelf/slot/port>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148038

6TANV57CLI-35A

2-345

Total Access/NetVanta Carrier CLI Dictionary

show ethernet evc-advertisement interface muxpondermidspeed <shelf/slot/port>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145596

2-346

6TANV57CLI-35A

Section 2, Commands - Common Commands

show evc WORD


UsetheshowevcWORDcommandtodisplayconfigurationparametersandthecurrent
statusforthespecifiedEVC.

Usage Examples
ThefollowingisasampleoutputoftheshowevcWORDcommand.
#show evc EVC1
All EVC Tags Available in MEN
Tag

Name

State

Status

--

EVC1

Disabled Disabled

Attributes:
CE-VLAN Preservation: Enabled
MEN Port: Invalid
#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64486

6TANV57CLI-35A

2-347

Total Access/NetVanta Carrier CLI Dictionary

show evc-map WORD


UsetheshowevcmapWORDcommandtodisplayconfigurationparametersandthecurrent
statusforthespecifiedEVCmap.

Usage Examples
ThefollowingisasampleoutputoftheshowevcmapWORDcommand.
#show evc-map MAP1
Name

State

Status

MAP1

Disabled Disabled

Match Criteria

Destination

UNI: Invalid

EVC: Not Defined

Untagged /

MEN-PRI: Inherit

Priority Tagged only: Disabled

MEN-QUEUE: Inherit
Policer: None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65634

2-348

6TANV57CLI-35A

Section 2, Commands - Common Commands

show evc-map WORD <shelf/slot>


UsetheshowevcmapWORD<shelf/slot>commandtodisplayconfigurationparametersand
thecurrentstatusforthespecifiedEVCmap.

Syntax Description
WORD

DisplayspecifiedEVCmap

Usage Examples
ThefollowingisasampleoutputoftheshowevcmapWORD<shelf/slot>command.
#show evc-map map110 1/9
Name

State

Status

-----------------------------------------------------------------------------MAP110

Enabled

Match Criteria

Running

Destination

---------------------------------------------------------------------------UNI: efm-port 31

EVC(root): 300 (300 )

Tagged/Untagged

MEN-Pri: Inherit

Attributes:
Description:
Encapsulation: IPoE
Manual Address Aging (minutes): 0
Relay Agent:
PPPoE Intermediate Agent
DHCP Snooping
Circuit Id Format:
IGMP:
Processing mode: block
Version: 2
Last Member Query Count: 2
Last Member Query Interval: 1000
Maximum Multicast Bandwidth (kbps): unlimited
Maximum Multicast Groups : unlimited
NetBios: Block
MAC Address

IP Address

Direction

------------------------------------------------00:17:3F:9B:EA:4C

10.200.200.39

downstream

6TANV57CLI-35A

2-349

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1)

Command ID
89715

2-350

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-history <shelf/slot>


Usetheshoweventhistory<shelf/slot>commandtodisplayspecificentriesinthecurrent
localeventhistorylog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventhistory<shelf/slot>command.
#show event-history
Using 526 bytes
2002.07.12 15:34:01 T1.t1 1/1 Yellow
2002.07.12 15:34:01 INTERFACE_STATUS.t1 1/1 changed state to down.
2002.07.12 15:34:02 T1.t1 1/1 No Alarms
2002.07.12 15:34:02 INTERFACE_STATUS.t1 1/1 changed state to up.
2002.07.12 15:34:03 INTERFACE_STATUS.eth 0/1 changed state to up.
2002.07.12 15:34:10 OPERATING_SYSTEM Warm Start
2002.07.12 15:34:12 PPP.NEGOTIATION LCP up
2002.07.12 15:34:12 PPP.NEGOTIATION IPCP up

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),QuadGigELM
(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM
(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),DS1Frame
Relay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46343

6TANV57CLI-35A

2-351

Total Access/NetVanta Carrier CLI Dictionary

show event-log detail <1-n>


Usetheshoweventlogdetail<1n>toviewdetailsofthespecifiedeventstoredinthesystem
eventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogdetail<1n>command.
#show event-log detail 1
System Event Log Entry Detail
User Account Name:
Record Type:

USER

Time Event Occurred:

12/08/08 10:42:20

Event Description:

Card: Removed

User Connection:
User IP Address:

0.0.0.0

Data Description:

Shelf(1) Slot(3)

Card Description:

Slot(3) EFM SHDSL32P

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86909

2-352

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-log statistics


Usetheshoweventlogstatisticscommandtodisplaystatisticalinformationforthenumber
anddifferenttypesofsystemeventsthatarerecordedinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogstatisticscommand.
>show event-log status
Login/logout events

: 00316

Account change events

: 00001

SNMP provisioning

: 00000

Network provisioning

: 00003

tftp ymodem updates

: 00000

SCA

: 00000

events

Security Options provisioning

: 00030

Date/time provisioning

: 00000

All line card slot events

: 00058

Leftover events
All Events

: 00230
: 00638 records,

57% Full

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77808

6TANV57CLI-35A

2-353

Total Access/NetVanta Carrier CLI Dictionary

show event-log type


[account|date|login|module|network|sca|security|snmp|upgrad
e]
Theshoweventlogtype[account|date|login|module|network|sca|security|snmp|tftp]
commandoutputsonlythoseeventsintheeventlogmarkedasbringofthespecifiedevent
type.

Syntax Description
account

Filterdisplaybyaccount

date

Filterdisplaybydate

login

Filterdisplaybylogin

module

Displaymoduleeventsonly

network

Displaynetworkeventsonly

sca

DisplaySCAeventsonly

security

Displaysecurityeventsonly

snmp

DisplaySNMPeventsonly

upgrade

Displayupgradeeventsonly

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtype
[account|date|login|module|network|sca|security|snmp|upgrade]command.
#show event-log type security
11/20/08 13:44:30:

Login accepted via LOCAL database, username = ADMIN

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-354

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
78674

6TANV57CLI-35A

2-355

Total Access/NetVanta Carrier CLI Dictionary

show event-log type account detail <1-n>


Usetheshoweventlogtypeaccountdetail<1n>toviewdetailsofthespecifiedaccountevent
storedinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypeaccountdetail<1n>command.
#show event-log type account detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 13:39:06

Event Description:

Acct Chg: Account Created

User Connection:
User IP Address:

0.0.0.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86911

2-356

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-log type date detail <1-n>


Usetheshoweventlogtypedatedetail<1n>toviewdetailsofthespecifieddateeventstored
inthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypedatedetail<1n>command.
#show event-log type date detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 13:39:06

Event Description:

Date

User Connection:
User IP Address:

0.0.0.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86913

6TANV57CLI-35A

2-357

Total Access/NetVanta Carrier CLI Dictionary

show event-log type login detail <1-n>


Usetheshoweventlogtypelogindetail<1n>toviewdetailsofthespecifiedloginevent
storedinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypelogindetail<1n>command.
#show event-log type login detail 1
System Event Log Entry Detail
User Account Name:
Record Type:

USER

Time Event Occurred:

12/08/08 11:05:59

Event Description:

Auto Logged Off Account

User Connection:
User IP Address:

0.0.0.0

Account Name:

newuser

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86915

2-358

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-log type module detail <1-n>


Usetheshoweventlogtypemoduledetail<1n>toviewdetailsofthespecifiedmoduleevent
storedinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypemoduledetail<1n>command.
#show event-log type module

detail 1

System Event Log Entry Detail


User Account Name:
Record Type:

USER

Time Event Occurred:

12/08/08 10:42:20

Event Description:

Card: Removed

User Connection:
User IP Address:

0.0.0.0

Data Description:

Shelf(1) Slot(3)

Card Description:

Slot(3) EFM SHDSL32P

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86917

6TANV57CLI-35A

2-359

Total Access/NetVanta Carrier CLI Dictionary

show event-log type network detail <1-n>


Usetheshoweventlogtypenetworkdetail<1n>toviewdetailsofthespecifiednetwork
eventstoredinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypenetworkdetail<1n>command.
#show event-log type network

detail 1

System Event Log Entry Detail


User Account Name:
Record Type:

USER

Time Event Occurred:

12/08/08 10:44:35

Event Description:

Primary

DNS Server

User Connection:
User IP Address:

0.0.0.0

Data Description:

Index() New IP(0.0.0.0) Old IP(1.2.3.4)

Card Description:

Slot(254) SCM

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86919

2-360

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-log type sca detail <1-n>


Usetheshoweventlogtypescadetail<1n>toviewdetailsofthespecifiedSystemConfigu
rationArchiveeventstoredinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypescadetail<1n>command.
#show event-log type sca detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 11:39:05

Event Description:

Remote Firmware Host

User Connection:

Craft

User IP Address:

0.0.0.0

Data Description:

Index()

Card Description:

Slot(254) SCM

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86921

6TANV57CLI-35A

2-361

Total Access/NetVanta Carrier CLI Dictionary

show event-log type security detail <1-n>


Usetheshoweventlogtypesecuritydetail<1n>toviewdetailsofthespecifiedsecurity
eventstoredinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypesecuritydetail<1n>command.
#show event-log type security detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 12:20:45

Event Description:

Sec Chg: Advisory Warning Disabled

User Connection:

IP

User IP Address:

172.22.118.27

Access Rights:

TECH SUPPORT

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86923

2-362

6TANV57CLI-35A

Section 2, Commands - Common Commands

show event-log type snmp detail <1-n>


Usetheshoweventlogtypesnmpdetail<1n>toviewdetailsofthespecifiedsnmpevent
storedinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypesnmpdetail<1n>command.
#show event-log type date detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 13:39:06

Event Description:

SNMP

User Connection:
User IP Address:

0.0.0.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86927

6TANV57CLI-35A

2-363

Total Access/NetVanta Carrier CLI Dictionary

show event-log type upgrade detail <1-n>


Usetheshoweventlogtypescadetail<1n>toviewdetailsofthespecifiedSystemConfigu
rationArchiveeventstoredinthesystemeventlog.

Usage Examples
Thefollowingisasampleoutputoftheshoweventlogtypeupgradedetail<1n>command.
#show event-log type sca detail 1
System Event Log Entry Detail
User Account Name:

newuser

Record Type:

USER

Time Event Occurred:

12/08/08 11:39:05

Event Description:

Remote Firmware Host

User Connection:

Craft

User IP Address:

0.0.0.0

Data Description:

Index()

Card Description:

Slot(254) SCM

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
120174

2-364

6TANV57CLI-35A

Section 2, Commands - Common Commands

show fan <shelf>


Usetheshowfan<shelf>commandtoviewthefanstatusinformationforthespecifiedshelf.

Usage Examples
Thefollowingisasampleoutputoftheshowfan<shelf>command.
#show fan 1
Unit Name = Fan Module
Fan Speed 1

3180 rpm

3180 rpm

3240 rpm

3300 rpm

Shelf Voltage

49.7 V

Temperature

0.0 C

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83056

6TANV57CLI-35A

2-365

Total Access/NetVanta Carrier CLI Dictionary

show file WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
100163

2-366

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces [adsl|atm|backplane|e1|efm-group|efmlink|efm-port|erps|ethernet|frame-relay|fxs|gigabitethernet|gpon|hdsl2|hdsl4|lag-group|muxponderhighspeed|muxponder-midspeed|packet-timing|pppgroup|ppp-link|processor-ethernet|pseudowire|rfvideo|shdsl|t1|t3|ten-gigabit-ethernet|vdsl]


Usetheshowinterfacescommandtodisplayconfigurationparameters,andcurrentstatistics
forallinterfacesofthespecifiedtype.

Syntax Description

6TANV57CLI-35A

interfaces

Displayallinterfaces

adsl

ShowallADSLports

atm

ShowallATMPorts

backplane

ShowallBackplaneinterfaces

e1

ShowallE1links

efmgroup

ShowallEFMgroups

efmlink

ShowallEFMLinks

efmport

ShowallEFMPorts

erps

ShowallERPSinterfaces

ethernet

ShowallEthernetports

framerelay

ShowallFrameRelayGroups

fxs

FXSinterface

gigabitethernet

ShowallGigabitEthernetports

gpon

ShowallGPONports

hdsl2

ShowallHDSL2ports

hdsl4

ShowallHDSL4ports

laggroup

IEEE802.3Clause43LinkAggregationGroup

muxponderhighspeed

Showallmuxponderhighspeedports

muxpondermidspeed

Showallmuxpondermidspeedports

packettiming

Showallpackettiminginterfaces

pppgroup

ShowallPPPgroups

ppplink

ShowallPPPlinks

2-367

Total Access/NetVanta Carrier CLI Dictionary

processorethernet

Datapathbetweentheprocessorandtheswitchingfabric

pseudowire

ShowallPseudowireinterfaces

rfvideo

RFVideointerface

shdsl

ShowallSHDSLports

t1

ShowallT1ports

t3

ShowallT3ports

tengigabitethernet

ShowallTenGigabitEthernetports

vdsl

ShowallVDSLports

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaces[adsl|atm|backplane|e1|efm
group|efmlink|efmport|erps|ethernet|framerelay|fxs|gigabit
ethernet|gpon|hdsl2|hdsl4|laggroup|muxponderhighspeed|muxponder
midspeed|packettiming|pppgroup|ppplink|processorethernet|pseudowire|rf
video|shdsl|t1|t3|tengigabitethernet|vdsl]command.
#show interfaces shdsl
SHDSL 1/0/1

IfId = 1

Description

SHDSL Port #1

State

Enabled - IS

Status

Down

Channel Rate (kbps)

ES

SES

UAS

791

CVC

LOSWS

791

SNR Margin(dB)

N/A,N/A,N/A (Cur, Min, Max)

Loop Attenuation (dB)

N/A,N/A,N/A (Cur, Min, Max)

Upstream PBO (dB)

Downstream PBO (dB)

Bonding Group

Annex

A/B

Line Probe

Disabled

Line Rate (N x DS0s)

0,3,89 (Cur, Min, Max)

SHDSL 1/0/2

IfId = 2

Description

SHDSL Port #2

State

Enabled - IS

...

2-368

6TANV57CLI-35A

Section 2, Commands - Common Commands

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).Ifthereisnotenoughroomonthescreen
forallavailabledata,theinformationwilltruncateatthebottomofthescreen.Inorderto
maximizetheamountofdatadisplayed,increasetheterminallength(usingtheterminal
lengthcommand;refertoterminallength<number>.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM(1187125L1),ADSLAMwithVDSL
SplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CH
DS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E
2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE
(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40995

6TANV57CLI-35A

2-369

Total Access/NetVanta Carrier CLI Dictionary

show interfaces adsl <shelf/slot/port> bit-allocation-table


[downstream|upstream]
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

downstream

Downstream

upstream

Upstream

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
120292

2-370

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces adsl <shelf/slot/port> circuit


[capabilities|inventory]
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

capabilities

ADSLcapabilitiesofeachelement

inventory

ADSLversion,serialnumber,vendorID,etc

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92162

6TANV57CLI-35A

2-371

Total Access/NetVanta Carrier CLI Dictionary

show interfaces adsl <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Usetheshowinterfacesadsl*performancestatisticscommandtodisplayall96stored
intervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowADSL15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92079

2-372

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces adsl <shelf/slot/port> performance-statistics


15-minute [<1-96>|realtime]
Usetheshowinterfacesadsl*performancestatistics15minutecommandtodisplay15
minuteintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

15minute

Cumulativedatasincestartofinterval

<196>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
ShowADSLcurrent15minPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92084

6TANV57CLI-35A

2-373

Total Access/NetVanta Carrier CLI Dictionary

show interfaces adsl <shelf/slot/port> performance-statistics


24-hour [<1-7>|realtime]
Usetheshowinterfacesadsl*performancestatistics24hourcommandtodisplay24hour
intervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

24hour

Cumulativedatasincestartofinterval

<17>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
ShowADSL24hourcurrentPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92080

2-374

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces adsl <shelf/slot/port> realtime


Usetheshowinterfacesadsl*realtimecommandtodisplayfullscreenADSLoutputinreal
time.

Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92078

6TANV57CLI-35A

2-375

Total Access/NetVanta Carrier CLI Dictionary

show interfaces adsl <shelf/slot/port> snr-table upstream


Usetheshowinterfacesvdsl<shelf/slot/port>snrtableupstreamcommandtodisplaythe
measuredupstreamSNRpertonetableforaspecifiedVDSLinterface/port.Thistableliststhe
measuresignaltonoiseratioonapercarrierbasis(toneindex)indB.

Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesadsl<shelf/slot/port>snrtable
upstreamcommand.
>show int vdsl 1/19/1 snr-table upstream

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
120296

2-376

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces atm <shelf/slot/port>


Functional Notes
Showspecificefmportinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
95728

6TANV57CLI-35A

2-377

Total Access/NetVanta Carrier CLI Dictionary

show interfaces atm <shelf/slot/port> realtime


Syntax Description
<shelf/slot/port>

DisplayspecifiedATMPort

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
95729

2-378

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces atm-group <shelf/slot/group> legacy-atm


Syntax Description
<shelf/slot/group>

DisplayspecifiedATMgroup

Functional Notes
xDSLAsynchronousTransferMode

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150653

6TANV57CLI-35A

2-379

Total Access/NetVanta Carrier CLI Dictionary

show interfaces atm-group legacy-atm


Functional Notes
ShowspecificATMgroupinterfacestatusandperformancestatistics.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150658

2-380

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces backplane <shelf/slot/port> performancestatistics [15-minute|24-hour]


Usetheshowinterfacesbackplane*performancestatisticscommandtodisplayall96stored
intervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowBackplane15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46103

6TANV57CLI-35A

2-381

Total Access/NetVanta Carrier CLI Dictionary

show interfaces backplane <shelf/slot/port> performancestatistics 15-minute <1-96>


Usetheshowinterfacesbackplane*performancestatistics15minute*commandtodisplaya
specific15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46105

2-382

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces backplane <shelf/slot/port> performancestatistics 24-hour <1-7>


Usetheshowinterfacesbackplane*performancestatistics24hour*commandtodisplaya
specific24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46107

6TANV57CLI-35A

2-383

Total Access/NetVanta Carrier CLI Dictionary

show interfaces backplane <shelf/slot/port> realtime


Usetheshowinterfacesbackplane*realtimecommandtodisplayfullscreenBackplane
outputinrealtime.

Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46102

2-384

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces e1 <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Usetheshowinterfacese1<shelf/slot/port>performancestatistics[15minute|24hour]
commandtodisplaytheE1performancemonitoringstatisticsforthespecifiedportin15
minuteor24hourincrements.

Syntax Description
<shelf/slot/port>

DisplayspecifiedE1links

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
45676

6TANV57CLI-35A

2-385

Total Access/NetVanta Carrier CLI Dictionary

show interfaces e1 <shelf/slot/port> performance-statistics 15minute <1-96>


Usetheshowinterfacese1*performancestatistics15minute*commandtodisplayaspecific
15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedE1links

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacese1<shelf/slot/port>performance
statistics15minute<196>command.
#show interfaces e1 1/0/1 performance-statistcs 15-minute 1-2
E1 1/0/1
15-Minute PM (1)
06:15
ESL

ESP

SESP

UASP

CVL

CVP

ESL

ESP

SESP

UASP

CVL

CVP

E1 1/0/1
15-Minute PM (2)
06:00

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

2-386

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
45678

6TANV57CLI-35A

2-387

Total Access/NetVanta Carrier CLI Dictionary

show interfaces e1 <shelf/slot/port> performance-statistics 24hour <1-7>


Usetheshowinterfacese1*performancestatistics24hour*commandtodisplayaspecific24
hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedE1links

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacese1<shelf/slot/port>performance
statistics24hour<17>command.
#show interfaces e1 1/0/1 performance-statistcs 24-hour 1-2
E1 1/0/1
24-Hour PM (1)
10/29
ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

E1 1/0/1
24-Hour PM (2)
10/28

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

2-388

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
45680

6TANV57CLI-35A

2-389

Total Access/NetVanta Carrier CLI Dictionary

show interfaces e1 <shelf/slot/port> realtime


Syntax Description
<shelf/slot/port>

DisplayspecifiedE1links

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFME1AM(1188802G1),E1CEM32PortAM(1188801G1)

Command ID
77225

2-390

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-group [<shelf/slot/group>|WORD]


Usetheshowinterfacesefmgroup*commandtodisplayconfigurationparameters,status,
andcurrentstatisticsforaspecifiedEFMgroup.

Functional Notes
Showspecificefmgroupinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45124

6TANV57CLI-35A

2-391

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 15-minute
Usetheshowinterfacesefmgroup<shelf/slot/group>performancestatistics15minute[<1
96>|realtime]commandtodisplay15minuteintervals.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmgroup[<shelf/slot/
group>|WORD]performancestatistics15minutecommand.
EFM Group 1/2/1 {XYZ} 15-Min PM (1) 12:0
Rx Frames

: 426

Tx Frames : 0

Rx Bytes

: 27264

Tx Bytes

Rx Bad Fragment

: 0

: 0

Rx Lost Fragment : 213


Rx Lost Start

: 0

Rx Lost End

: 0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45130

2-392

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 15-minute <1-96>
Usetheshowinterfacesefmgroup*performancestatistics15minute*commandtodisplaya
specific15minuteinterval.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Functional Notes
ShowspecificEFMGroup15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45131

6TANV57CLI-35A

2-393

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 15-minute realtime
Usetheshowinterfacesefmgroup*performancestatistics15minute*realtimecommandto
displayaspecific15minuteintervalinrealtime.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1)

Command ID
45132

2-394

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 24-hour
Usetheshowinterfacesefmgroup<shelf/slot/group>performancestatistics24hour[<1
7>|realtime]commandtodisplay24hourintervals.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmgroup[<shelf/slot/
group>|WORD]performancestatistics24hourcommand.
EFM Group 1/2/1 {XYZ} 24-Hour PM (1) 9/4
Rx Frames

: 766

Tx Frames : 31

Rx Bytes

: 49103

Tx Bytes

Rx Bad Fragment

: 0

: 2232

Rx Lost Fragment : 383


Rx Lost Start

: 0

Rx Lost End

: 0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45127

6TANV57CLI-35A

2-395

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 24-hour <1-7>
Usetheshowinterfacesefmgroup*performancestatistics24hour*commandtodisplaya
specific24hourinterval.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Functional Notes
ShowspecificEFMGroup24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45129

2-396

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-group [<shelf/slot/group>|WORD]


performance-statistics 24-hour realtime
Usetheshowinterfacesefmgroup*performancestatistics24hour*realtimecommandto
displayaspecific24hourintervalinrealtime.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1)

Command ID
45128

6TANV57CLI-35A

2-397

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-group [<shelf/slot/group>|WORD]


realtime
Usetheshowinterfacesefmgroup*realtimecommandtodisplayfullscreenEFMGroup
outputinrealtime.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1)

Command ID
45125

2-398

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-group [<shelf/slot/group>|WORD]


subtended-host
Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

WORD

Specifiedinterfacebyalias

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
109806

6TANV57CLI-35A

2-399

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>]
Usetheshowinterfacesefmlinkcommandtodisplayconfigurationparameters,status,and
currentstatisticsforaspecifiedEFMlink.

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]command.
#show interfaces efm-link 1/0/1
EFM Link 1/0/1

IfId = 14

Bonding Group

Status

LOF

Tx Fragments

Rx Fragments

Rx Errored Fragments

Rx Small Fragments

Rx Large Fragments

Rx Discarded Fragments

Rx FCS Errors

Rx Coding Errors

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45144

2-400

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute
Usetheshowinterfacesefmlink<shelf/slot/port>performancestatistics15minute[<1
96>|realtime]commandtodisplayaspecific15minuteintervalorarangeofintervals.

Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics15minutecommand.
#show interfaces efm-link 1/0/1 performance-statistcs 15-minute 1-2
EFM Link 1/0/1
15-Minute PM (1)
22:00
Tx Fragments

Rx Fragments

Rx Errored Fragments

Rx Small Fragments

Rx Large Fragments

Rx Discarded Fragments

Rx FCS Errors

Rx Coding Errors

Tx Fragments

Rx Fragments

Rx Errored Fragments

Rx Small Fragments

Rx Large Fragments

Rx Discarded Fragments

Rx FCS Errors

Rx Coding Errors

EFM Link 1/0/1


15-Minute PM (2)
21:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-401

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45150

2-402

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute <1-96>
Usetheshowinterfacesefmlinkperformancestatistics15minutecommandtodisplaya
specific15minuteinterval.

Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics15minute<196>command.
#show interfaces efm-link 1/0/1 performance-statistcs 15-minute 1-2
EFM Link 1/0/1
15-Minute PM (1)
22:00
Tx Fragments

Rx Fragments

Rx Errored Fragments

Rx Small Fragments

Rx Large Fragments

Rx Discarded Fragments

Rx FCS Errors

Rx Coding Errors

Tx Fragments

Rx Fragments

Rx Errored Fragments

Rx Small Fragments

Rx Large Fragments

Rx Discarded Fragments

Rx FCS Errors

Rx Coding Errors

EFM Link 1/0/1


15-Minute PM (2)
21:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-403

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45151

2-404

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute realtime
Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45152

6TANV57CLI-35A

2-405

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour
Usetheshowinterfacesefmlink<shelf/slot/port>performancestatistics24hour[<1
7>|realtime]commandtodisplayaspecific24hourintervalorarangeofintervals.

Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics24hourcommand.
#show interfaces efm-link 1/0/1 performance-statistcs 24-hour 1-2
EFM Link 1/0/1
24-Hour PM (1)
10/30
Tx Fragments

n/a

Rx Fragments

n/a

Rx Errored Fragments

n/a

Rx Small Fragments

n/a

Rx Large Fragments

n/a

Rx Discarded Fragments

n/a

Rx FCS Errors

n/a

Rx Coding Errors

n/a

Tx Fragments

n/a

Rx Fragments

n/a

Rx Errored Fragments

n/a

Rx Small Fragments

n/a

Rx Large Fragments

n/a

Rx Discarded Fragments

n/a

Rx FCS Errors

n/a

Rx Coding Errors

n/a

EFM Link 1/0/1


24-Hour PM (2)
10/29

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-406

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45147

6TANV57CLI-35A

2-407

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour <1-7>
Usetheshowinterfacesefmlinkperformancestatistics24hourcommandtodisplaya
specific24hourinterval.

Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics24hour<17>command.
#show interfaces efm-link 1/0/1 performance-statistcs 24-hour 1-2
EFM Link 1/0/1
24-Hour PM (1)
10/30
Tx Fragments

n/a

Rx Fragments

n/a

Rx Errored Fragments

n/a

Rx Small Fragments

n/a

Rx Large Fragments

n/a

Rx Discarded Fragments

n/a

Rx FCS Errors

n/a

Rx Coding Errors

n/a

Tx Fragments

n/a

Rx Fragments

n/a

Rx Errored Fragments

n/a

Rx Small Fragments

n/a

Rx Large Fragments

n/a

Rx Discarded Fragments

n/a

Rx FCS Errors

n/a

Rx Coding Errors

n/a

EFM Link 1/0/1


24-Hour PM (2)
10/29

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-408

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45148

6TANV57CLI-35A

2-409

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour realtime
Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45149

2-410

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] realtime
Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45145

6TANV57CLI-35A

2-411

Total Access/NetVanta Carrier CLI Dictionary

show interfaces efm-port <shelf/slot/port>


Functional Notes
Showspecificefmportinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
77514

2-412

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces efm-port <shelf/slot/port> realtime


Syntax Description
<shelf/slot/port>

DisplayspecifiedEFMPort

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
77515

6TANV57CLI-35A

2-413

Total Access/NetVanta Carrier CLI Dictionary

show interfaces erps <shelf/slot/ring> [performancestatistics|realtime]


UsageExample:SM4GE#showinterfaceserps1/A/1Interface:ring1/A/1StationName:SM
Net1RPLOwner:YesRPLLink:EastWTRtimerinterval:60secWTRtimerrunning:NoWTR
timeremaining:0secMessageTimerinterval:500msecGuardtimerinterval:500msecEn
abled:YesStatus:NRInterfaceStateCommandedstateWest:gigabitethernet
1/A/1Up/ForwardingidleEast:gigabitethernet1/B/1Down/BlockedFSThestatuscould
becomposedofBITS:NR,WTR,RMS,MS,RSF,SF,RFS,FS

Syntax Description
<shelf/slot/ring>

DisplayspecifiedERPSring

performancestatistics

Historicalperformancemonitoringdata

realtime

Periodicallyupdateddisplay

Functional Notes
Showspecificringinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77110

2-414

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces erps <shelf/slot/ring> performance-statistics


[15-minute|24-hour]
Syntax Description
<shelf/slot/ring>

DisplayspecifiedERPSring

performancestatistics

Historicalperformancemonitoringdata

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
Showring15min/24hourPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77115

6TANV57CLI-35A

2-415

Total Access/NetVanta Carrier CLI Dictionary

show interfaces erps <shelf/slot/ring> performance-statistics


15-minute <0-96>
UsageExample:SM4GE#showinterfacering1/A/1performancestatistics15minute96
RingWestEastReceiveRAPSNRRB:211ReceiveRAPS
NRRBDNF:422ReceiveRAPSNR:633Receive
RAPSFS:844ReceiveRAPSSF:1055Receive
RAPSMS:1266ReceiveRAPSIgnored:1477Receive
RAPSTotal:1688TransmitRAPSNRRB:21
1TransmitRAPSNRRBDNF:422TransmitRAPSNR:63
3TransmitRAPSFS:844TransmitRAPSSF:105
5TransmitRAPSMS:1266TransmitRAPSTotal:147
7ProtectionSwitches:8

Syntax Description
<shelf/slot/ring>

DisplayspecifiedERPSring

Functional Notes
Showspecificring15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77117

2-416

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces erps <shelf/slot/ring> performance-statistics


24-hour <0-7>
Syntax Description
<shelf/slot/ring>

DisplayspecifiedERPSring

Functional Notes
Showspecificring24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77119

6TANV57CLI-35A

2-417

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ethernet <shelf/slot/port>


[realtime|subtended-host]
Usetheshowinterfacesethernetcommandtodisplayconfigurationparameters,status,and
currentstatisticsforaspecified10/100Ethernetport.

Syntax Description
<shelf/slot/port>

DisplayspecifiedEthernetport

realtime

Periodicallyupdateddisplay

subtendedhost

Subtendedhoststatus

Functional Notes
Showspecificethernetinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44840

2-418

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ethernet <shelf/slot/port> performancestatistics [15-minute|24-hour]


Usetheshowinterfacesethernet*performancestatisticscommandtodisplayall96stored
intervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedEthernetport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowEthernet15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44842

6TANV57CLI-35A

2-419

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ethernet <shelf/slot/port> performancestatistics 15-minute <1-96>


Usetheshowinterfacesethernet*performancestatistics15minute*commandtodisplay
datain15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedEthernetport

Functional Notes
ShowspecificEthernet15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44844

2-420

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ethernet <shelf/slot/port> performancestatistics 24-hour <1-7>


Usetheshowinterfacesethernet*performancestatistics24hour*commandtodisplaydata
in24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedEthernetport

Functional Notes
ShowspecificEthernet24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44846

6TANV57CLI-35A

2-421

Total Access/NetVanta Carrier CLI Dictionary

show interfaces frame-relay [<shelf/slot/group> |dlci]


Syntax Description
framerelay

ShowallFrameRelayGroups

<shelf/slot/group>

Specifiedgroup

dlci

ShowallFrameRelayGroupPVCs

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133724

2-422

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces frame-relay <shelf/slot/group> dlci


Syntax Description
<shelf/slot/group>

Specifiedgroup

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133735

6TANV57CLI-35A

2-423

Total Access/NetVanta Carrier CLI Dictionary

show interfaces frame-relay <shelf/slot/group> dlci <16-991>


performance-statistics [15-minutes|24-hour]
Syntax Description
<shelf/slot/group>

Specifiedgroup

<16991>

DLCI

15minutes

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
Showframerelay15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133755

2-424

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces frame-relay <shelf/slot/group> dlci <16-991>


performance-statistics 15-minutes [<1-96>|realtime]
Syntax Description
<shelf/slot/group>

Specifiedgroup

<16991>

DLCI

15minutes

Cumulativedatasincestartofinterval

<196>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
Showframerelaycurrent15minPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133759

6TANV57CLI-35A

2-425

Total Access/NetVanta Carrier CLI Dictionary

show interfaces frame-relay <shelf/slot/group> dlci <16-991>


performance-statistics 24-hour [<1-7>|realtime]
Syntax Description
<shelf/slot/group>

Specifiedgroup

<16991>

DLCI

24hour

Cumulativedatasincestartofinterval

<17>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
Showframerelay24hourcurrentPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133756

2-426

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces frame-relay <shelf/slot/group> dlci <16-991>


realtime
Syntax Description
<shelf/slot/group>

Specifiedgroup

<16991>

DLCI

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133737

6TANV57CLI-35A

2-427

Total Access/NetVanta Carrier CLI Dictionary

show interfaces frame-relay <shelf/slot/group> performancestatistics [15-minutes|24-hour]


Syntax Description
<shelf/slot/group>

Specifiedgroup

15minutes

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
Showframerelay15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133747

2-428

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces frame-relay <shelf/slot/group> performancestatistics 15-minutes [<1-96>|realtime]


Syntax Description
<shelf/slot/group>

Specifiedgroup

15minutes

Cumulativedatasincestartofinterval

<196>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
Showframerelaycurrent15minPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133751

6TANV57CLI-35A

2-429

Total Access/NetVanta Carrier CLI Dictionary

show interfaces frame-relay <shelf/slot/group> performancestatistics 24-hour [<1-7>|realtime]


Syntax Description
<shelf/slot/group>

Specifiedgroup

24hour

Cumulativedatasincestartofinterval

<17>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Functional Notes
Showframerelay24hourcurrentPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133748

2-430

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces frame-relay <shelf/slot/group> realtime


Syntax Description
<shelf/slot/group>

Specifiedgroup

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133726

6TANV57CLI-35A

2-431

Total Access/NetVanta Carrier CLI Dictionary

show interfaces fxs [<shelf/slot/port>|<remote-index>]


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95583

2-432

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces fxs [<shelf/slot/port>|<remote-index>] line-test


Syntax Description
<shelf/slot/port>

Interfacenumber

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95585

6TANV57CLI-35A

2-433

Total Access/NetVanta Carrier CLI Dictionary

show interfaces fxs [<shelf/slot/port>|<remote-index>]


realtime
Syntax Description
<shelf/slot/port>

Interfacenumber

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95584

2-434

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>]


Usetheshowinterfacesgigabitethernetcommandtodisplayconfigurationparameters,
status,andcurrentstatisticsforaspecifiedGigabitEthernetport.

Functional Notes
Showspecificgigabitethernetinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),TA300
2POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE
(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44849

6TANV57CLI-35A

2-435

Total Access/NetVanta Carrier CLI Dictionary

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] performance-statistics 15-minute


Usetheshowinterfacesgigabitethernet*performancestatistics15minutecommandto
displaydatain15minuteintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowGigabitEthernetcurrent15minPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44852

2-436

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] performance-statistics 15-minute <1-96>


Usetheshowinterfacesgigabitethernet*performancestatistics15minute*commandto
displaydatainaspecific15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowspecificGigabitEthernet15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44853

6TANV57CLI-35A

2-437

Total Access/NetVanta Carrier CLI Dictionary

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] performance-statistics 24-hour


Usetheshowinterfacesgigabitethernet*performancestatistics24hourcommandtodisplay
datain24hourintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowGigabitEthernet24hourcurrentPM

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44854

2-438

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] performance-statistics 24-hour <1-7>


Usetheshowinterfacesgigabitethernet*performancestatistics24hour*commandto
displaydatainaspecific24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowspecificGigabitEthernet24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44855

6TANV57CLI-35A

2-439

Total Access/NetVanta Carrier CLI Dictionary

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] pluggable


Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
83038

2-440

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] realtime


UsetheshowinterfacesgigabitethernetrealtimecommandtodisplayfullscreenGigabit
Ethernetoutputinrealtime.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),TA300
2POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE
(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

6TANV57CLI-35A

2-441

Total Access/NetVanta Carrier CLI Dictionary

Command ID
44850

2-442

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gigabit-ethernet [<shelf/slot/port>|<remoteindex>] subtended-host


Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
109805

6TANV57CLI-35A

2-443

Total Access/NetVanta Carrier CLI Dictionary

show interfaces gpon <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowGPON15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136137

2-444

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gpon <shelf/slot/port> performance-statistics


15-minute <1-96>
Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

Functional Notes
ShowspecificGPON15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136140

6TANV57CLI-35A

2-445

Total Access/NetVanta Carrier CLI Dictionary

show interfaces gpon <shelf/slot/port> performance-statistics


24-hour <1-7>
Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

Functional Notes
ShowspecificGPON24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136142

2-446

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces gpon <shelf/slot/port> subtended-host


Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
142876

6TANV57CLI-35A

2-447

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl2 <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL2port

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowHDSL215min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43912

2-448

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces hdsl2 <shelf/slot/port> performance-statistics


15-minute <1-96>
Usetheshowinterfaceshdsl2*performancestatistics15minute*commandtodisplaya
specific15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL2port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl2<shelf/slot/port>performance
statistics15minute<196>command.
#show interfaces hdsl2 1/0/1 performance-statistcs 15-minute 1-2
HDSL2 1/0/1

IfId = 1

15-Minute PM (1)
10:15
ES

SES

UAS

ES

SES

UAS

HDSL2 1/0/1

IfId = 1

15-Minute PM (2)
10:00

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43916

6TANV57CLI-35A

2-449

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl2 <shelf/slot/port> performance-statistics


24-hour <1-7>
Usetheshowinterfaceshdsl2*performancestatistics24hour*commandtodisplaya
specific24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL2port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl2<shelf/slot/port>performance
statistics24hour<17>command.
#show interfaces hdsl2 1/0/1 performance-statistcs 24-hour 1-2
HDSL2 1/0/1

IfId = 1

24-Hour PM (1)
11/07
ES

n/a

SES

n/a

UAS

n/a

ES

n/a

SES

n/a

UAS

n/a

HDSL2 1/0/1

IfId = 1

24-Hour PM (2)
11/06

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43915

2-450

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces hdsl2 <shelf/slot/port> splice-detect [24hour|histogram]


Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL2port

24hour

Cumulativedatasincestartofinterval

histogram

GetCurrentSpliceDetectStatistics

Functional Notes
ShowSpliceDetectStatistics

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43919

6TANV57CLI-35A

2-451

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl2 <shelf/slot/port> splice-detect 24-hour


<1-14>
Usetheshowinterfaceshdsl2*splicedetect24hour*commandtodisplaythehistorical24
hoursplicedetectdata.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL2port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl2<shelf/slot/port>splicedetect
24hour<114>command.
#show interfaces hdsl2 1 splice-detect 24-hour 1-2
Interval 1 Splice Detect Data
HDSL2 Port 1
Summary: Loss of Signal
Interval 2 Splice Detect Data
HDSL2 Port 1
Summary: Loss of Signal

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43921

2-452

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces hdsl4 <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL4port

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowHDSL415min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
43924

6TANV57CLI-35A

2-453

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl4 <shelf/slot/port> performance-statistics


15-minute <1-96>
Usetheshowinterfaceshdsl4*performancestatistics15minute*commandtodisplaya
specific15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL4port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl4<shelf/slot/port>performance
statistics15minute<196>command.
#show interfaces hdsl4 1/0/1 performance-statistcs 15-minute 1-2
HDSL4 1/0/1, IfId = 1, Pair 1
15-Minute PM (1)
22:00
ES

SES

UAS

ES

SES

UAS

ES

SES

UAS

27

ES

SES

UAS

27

HDSL4 1/0/1, IfId = 1, Pair 2


15-Minute PM (1)
22:00

HDSL4 1/0/1, IfId = 1, Pair 1


15-Minute PM (2)
21:45

HDSL4 1/0/1, IfId = 1, Pair 2


15-Minute PM (2)
21:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-454

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
43929

6TANV57CLI-35A

2-455

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl4 <shelf/slot/port> performance-statistics


24-hour <1-7>
Usetheshowinterfaceshdsl4*performancestatistics24hour*commandtodisplaya
specific24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL4port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl4<shelf/slot/port>performance
statistics24hour<17>command.
#show interfaces hdsl4 1/0/1 performance-statistcs 24-hour 1-2
HDSL4 1/0/1, IfId = 1, Pair 1
24-Hour PM (1)
11/20
ES

n/a

SES

n/a

UAS

n/a

ES

n/a

SES

n/a

UAS

n/a

ES

n/a

SES

n/a

UAS

n/a

ES

n/a

SES

n/a

UAS

n/a

HDSL4 1/0/1, IfId = 1, Pair 2


24-Hour PM (1)
11/20

HDSL4 1/0/1, IfId = 1, Pair 1


24-Hour PM (2)
11/19

HDSL4 1/0/1, IfId = 1, Pair 2


24-Hour PM (2)
11/19

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-456

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
43928

6TANV57CLI-35A

2-457

Total Access/NetVanta Carrier CLI Dictionary

show interfaces hdsl4 <shelf/slot/port> splice-detect [24hour|histogram]


Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL4port

24hour

Cumulativedatasincestartofinterval

histogram

GetCurrentSpliceDetectStatistics

Functional Notes
ShowSpliceDetectStatistics

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
43932

2-458

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces hdsl4 <shelf/slot/port> splice-detect 24-hour


<1-14>
Usetheshowinterfaceshdsl4*splicedetect24hour*commandtodisplaythehistorical24
hoursplicedetectdata.

Syntax Description
<shelf/slot/port>

DisplayspecifiedHDSL4port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfaceshdsl4<shelf/slot/port>splicedetect
24hour<114>command.
#show interfaces hdsl4 1/0/1 splice-detect 24-hour 1-2
Interval 1 Splice Detect Data
HDSL4 1/0/1, IfId = 1, Pair 1
Summary: Loss of Signal
HDSL4 1/0/1, IfId = 1, Pair 2
Summary: Loss of Signal
Interval 2 Splice Detect Data
HDSL4 1/0/1, IfId = 1, Pair 1
Summary: Loss of Signal
HDSL4 1/0/1, IfId = 1, Pair 2
Summary: Loss of Signal

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
43934

6TANV57CLI-35A

2-459

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ip-host WORD [<shelf/slot>|<remote-index>]


Syntax Description
WORD

NameofIPHost

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
95882

2-460

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ip-host slot <shelf/slot>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),TA3242POTS4GE
(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
154222

6TANV57CLI-35A

2-461

Total Access/NetVanta Carrier CLI Dictionary

show interfaces lag-group <shelf/slot/group>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83177

2-462

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces lag-group <shelf/slot/group> realtime


Syntax Description
<shelf/slot/group>

DisplayspecifiedLAGgroup

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83178

6TANV57CLI-35A

2-463

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-highspeed {<shelf/slot/port> }


Functional Notes
Usetheshowinterfacesmuxponderhighspeedcommandtodisplayconfigurationparam
etersstatusandcurrentstatisticsforaspecifiedmuxponderhighspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136009

2-464

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-highspeed <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usetheshowinterfacesmuxponderhighspeed*performancestatisticscommandtodisplay
allstoredintervals.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowMuxponderHighspeed15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145587

6TANV57CLI-35A

2-465

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-highspeed <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowinterfacesmuxponderhighspeed*performancestatistics15minute*command
todisplaydatainaspecific15minuteinterval.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

Functional Notes
ShowspecificMuxponderHighspeed15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145589

2-466

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-highspeed <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowinterfacesmuxponderhighspeed*performancestatistics24hour*commandto
displaydatainaspecific24hourinterval.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

Functional Notes
ShowspecificMuxponderHighspeed24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145591

6TANV57CLI-35A

2-467

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-highspeed <shelf/slot/port>


pluggable
Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145592

2-468

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-highspeed <shelf/slot/port>


realtime
Usetheshowinterfacesmuxponderhighspeedrealtimecommandtodisplayfullscreen
MuxponderHighspeedoutputinrealtime.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145586

6TANV57CLI-35A

2-469

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-highspeed <shelf/slot/port>


subtended-host
Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxponderhighspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148039

2-470

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-midspeed {<shelf/slot/port> }


Functional Notes
Usetheshowinterfacesmuxpondermidspeedcommandtodisplayconfigurationparameters
statusandcurrentstatisticsforaspecifiedmuxpondermidspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136004

6TANV57CLI-35A

2-471

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-midspeed <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usetheshowinterfacesmuxpondermidspeed*performancestatisticscommandtodisplay
allstoredintervals.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowMuxponderMidspeed15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145578

2-472

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-midspeed <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowinterfacesmuxpondermidspeed*performancestatistics15minute*command
todisplaydatainaspecific15minuteinterval.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

Functional Notes
ShowspecificMuxponderMidspeed15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145580

6TANV57CLI-35A

2-473

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-midspeed <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowinterfacesmuxpondermidspeed*performancestatistics24hour*commandto
displaydatainaspecific24hourinterval.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

Functional Notes
ShowspecificMuxponderMidspeed24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145582

2-474

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-midspeed <shelf/slot/port>


pluggable
Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145583

6TANV57CLI-35A

2-475

Total Access/NetVanta Carrier CLI Dictionary

show interfaces muxponder-midspeed <shelf/slot/port>


realtime
Usetheshowinterfacesmuxpondermidspeedrealtimecommandtodisplayfullscreen
MuxponderMidspeedoutputinrealtime.

Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145585

2-476

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces muxponder-midspeed <shelf/slot/port>


subtended-host
Syntax Description
<shelf/slot/port>

Displayaspecifiedmuxpondermidspeedport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145584

6TANV57CLI-35A

2-477

Total Access/NetVanta Carrier CLI Dictionary

show interfaces packet-timing <shelf/slot>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144188

2-478

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-group <shelf/slot/group> performancestatistics [15-minute|24-hour]


Usetheshowinterfacespppgroup<shelf/slot/group>performancestatisticscommandto
displaystatisticsforthespecifiedPPPgroupin15minuteor24hourintervals..

Syntax Description
<shelf/slot/group>

DisplayspecifiedPPPgroup

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89344

6TANV57CLI-35A

2-479

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-group <shelf/slot/group> performancestatistics 15-minute [<1-96>|realtime]


Usetheshowinterfacespppgroup<shelf/slot/group>performancestatistics15minutes
commandtodisplaystatisticsforthespecifiedPPPgroupin15minuteintervals..

Syntax Description
<shelf/slot/group>

DisplayspecifiedPPPgroup

15minute

Cumulativedatasincestartofinterval

<196>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacespppgroup<shelf/slot/group>perfor
mancestatistics15minute[<196>|realtime]command.
#show interface

ppp-group 1/3/2 performance-statistics

15-minutes

PPP Group 1/3/2 {GROUP 3/2} 15-Min PM (Current)


Rx Frames

: 0

Tx Frames

: 0

Rx Bytes

: 0

Tx Bytes

: 0

Rx Discard

: 0

Tx Discard

: 0

Rx Errors

: 0

Tx Errors

: 0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89345

2-480

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-group <shelf/slot/group> performancestatistics 24-hour [<1-7>|realtime]


Usetheshowinterfacespppgroup<shelf/slot/group>performancestatistics24hour
commandtodisplaystatisticsforthespecifiedPPPgroupin24hourintervals.

Syntax Description
<shelf/slot/group>

DisplayspecifiedPPPgroup

24hour

Cumulativedatasincestartofinterval

<17>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacespppgroup<shelf/slot/group>perfor
mancestatistics24hour[<17>|realtime]command.
#show interface

ppp-group

1/3/2 performance-statistics 24-hour

PPP Group 1/3/2 {GROUP 3/2} 24-Hour PM (Current)


Rx Frames

: 0

Tx Frames

: 0

Rx Bytes

: 0

Tx Bytes

: 0

Rx Discard

: 0

Tx Discard

: 0

Rx Errors

: 0

Tx Errors

: 0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89348

6TANV57CLI-35A

2-481

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-group <shelf/slot/group> realtime


Usetheshowinterfacepppgroup<shelf/slot/group>realtimecommandtodisplayconfigu
rationparameters,status,andcurrentstatisticsforforthespecifiedPPPgroup.

Syntax Description
<shelf/slot/group>

DisplayspecifiedPPPgroup

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacespppgroup<shelf/slot/group>
realtimecommand.
#show interface ppp-group 1/3/2 realtime
------------------------------------------------------------------------------PPP Group 1/3/2 {GROUP 3/2} is ENABLED and UP
Interface Status:
Active Slot

: 3

Provisioned Links

: 3/1:2

Active Links

: 3/1:2

LCP State

: OPENED

NCP State

: OPENED

Peer IP Address

: 10.10.10.1

Peer IP Gateway

: 10.10.10.1

Peer IP Primary DNS

: 0.0.0.0

Peer IP Secondary DNS

: 0.0.0.0

MTU

: 1500

Restart Timer

3 seconds

Max Terminate Counter

2 packets

Max Configure Counter

: 10 packets

Max Failure Counter

Keep Alive Rate

: 10 seconds

FCS Size

: 16

LQM

: enabled

Magic Number

: disabled

ACF Compression

: disabled

PF Compression

: disabled

5 packets

Running Totals:

2-482

Tx Packets

: 0

Tx Octets

: 0

Tx Discard Count

: 0

6TANV57CLI-35A

Section 2, Commands - Common Commands

Tx Error Count

: 0

Rx Packets

: 0

Rx Bytes

: 4294967280

Rx Discard Count

: 0

Rx Error Count

: 0

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89351

6TANV57CLI-35A

2-483

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>]
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89479

2-484

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute
Usetheshowinterfacesppplink<shelf/slot/port>performancestatistics15minutes
commandtodisplaystatisticsforthespecifiedPPPlinkin15minuteintervals.

Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesppplink[<shelf/slot/port>|<shelf/
slot/port:chan>]performancestatistics15minutecommand.
#show interface ppp-link 1/3/1:2 performance-statistics 15-minute
PPP Link 1/3/1:2 15-Min PM (Current)
Rx Packets

: 42

Tx Packets

: 42

Rx Bytes

: 588

Tx Bytes

: 588

Rx Discard

: 0

Tx Discard

: 0

Rx Error

: 0

Tx Error

: 0

Rx Good Byte Count

: 588

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89481

6TANV57CLI-35A

2-485

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute <1-96>
Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89482

2-486

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute realtime
Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89483

6TANV57CLI-35A

2-487

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour
Usetheshowinterfacesppplink<shelf/slot/port>performancestatistics24hourcommandto
displaystatisticsforthespecifiedPPPlinkin24hourintervals.

Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesppplink[<shelf/slot/port>|<shelf/
slot/port:chan>]performancestatistics24hourcommand.
#show interface ppp-link 1/3/1:2 performance-statistics 24-hour
PPP Link 1/3/1:2 24-Hour PM (Current)
Rx Packets

: 7682

Tx Packets

: 7682

Rx Bytes

: 107548

Tx Bytes

: 107548

Rx Discard

: 0

Tx Discard

: 0

Rx Error

: 0

Tx Error

: 0

Rx Good Byte Count

: 107548

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89484

2-488

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour <1-7>
Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89485

6TANV57CLI-35A

2-489

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour realtime
Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89486

2-490

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ppp-link [<shelf/slot/port>|<shelf/slot/


port:chan>] realtime
Usetheshowinterfaceppplink<shelf/slot/port>realtimecommandtodisplayconfiguration
parameters,status,andcurrentstatisticsforforthespecifiedPPPlink.

Syntax Description
<shelf/slot/port>

SpecifiedPPPlink

<shelf/slot/port:chan>

SpecifiedPPPlink

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesppplink[<shelf/slot/port>|<shelf/
slot/port:chan>]realtimecommand.
#show interface ppp-link 1/3/1:2 realtime
------------------------------------------------------------------------------PPP Link 1/3/1:2 on PPP Group 1/3/2 is ENABLED and UP
Installed

: YES

LCP State

: OPENED

Running Totals:

6TANV57CLI-35A

Tx Packets

: 17816

Tx Bytes

: 249432

Tx Discards

: 0

Tx Errors

: 0

Rx Packets

: 17816

Rx Bytes

: 249432

Rx Discards

: 0

Rx Errors

: 0

Rx Good Bytes

: 249432

2-491

Total Access/NetVanta Carrier CLI Dictionary

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89487

2-492

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces pseudowire [<shelf/slot>|<shelf/slot/


pwe>|<remote-index>]
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131179

6TANV57CLI-35A

2-493

Total Access/NetVanta Carrier CLI Dictionary

show interfaces pseudowire [<shelf/slot>|<shelf/slot/


pwe>|<remote-index>] performance-statistics 15-minute
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131185

2-494

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces pseudowire [<shelf/slot>|<shelf/slot/


pwe>|<remote-index>] performance-statistics 15-minute <196>
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131188

6TANV57CLI-35A

2-495

Total Access/NetVanta Carrier CLI Dictionary

show interfaces pseudowire [<shelf/slot>|<shelf/slot/


pwe>|<remote-index>] performance-statistics 24-hour
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131184

2-496

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces pseudowire [<shelf/slot>|<shelf/slot/


pwe>|<remote-index>] performance-statistics 24-hour <1-7>
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131186

6TANV57CLI-35A

2-497

Total Access/NetVanta Carrier CLI Dictionary

show interfaces rf-video <remote-index>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R
2POTS2GERFoG(1187715G1),TA3612POTS1GERF(1287711G1),TA3622POTS
2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GE
HPNARF(1287712G3)

Command ID
144624

2-498

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> [circuit|realtime]


Usetheshowinterfacesshdsl*commandtodisplayconfigurationparameters,status,and
currentstatisticsforaspecifiedSHDSLport.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

circuit

Displayallelementsintheendtoendcircuit

realtime

Periodicallyupdateddisplay

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>
[circuit|realtime]command.
#show interfaces shdsl 1/0/1
SHDSL 1/0/1

IfId = 1

Description

SHDSL Port #1

State

Enabled - IS

Status

Up

Channel Rate (kbps)

5696

ES

SES

UAS

40

CVC

LOSWS

40

SNR Margin(dB)

19,19,19 (Cur, Min, Max)

Loop Attenuation (dB)

0,0,0 (Cur, Min, Max)

Upstream PBO (dB)

Downstream PBO (dB)

Bonding Group

Annex

A/B

Line Probe

Disabled

Line Rate (N x DS0s)

89,3,89 (Cur, Min, Max)

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-499

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42661

2-500

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> circuit inventory


Usetheshowinterfacesshdslcircuitinventorycommandtodisplayinformationabouteach
elementinthecircuit.TheinformationdisplayedisdiscoveredthroughtheEmbeddedOpera
tionsChannelasdescribedinITUG991.2.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>circuit
inventorycommand.
>show interfaces shdsl 1 circuit inventory
SHDSL 1 IfId = 1
LTU
Vendor ID
Model Number

ADTN
1200633G4

Serial Number H23G4548


Standard Version

List Number
Issue Number
Software Version
Equipment Code
Vendor Other

4
1
C00
SIM5K10BRA
0F6936EE

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42671

6TANV57CLI-35A

2-501

Total Access/NetVanta Carrier CLI Dictionary

show interfaces shdsl <shelf/slot/port> circuit performancestatistics [15-minute|24-hour]


Usetheshowinterfacesshdsl*circuitperformancestatisticscommandtodisplaythe
historicalperformancemonitoringstatisticsforeachSHDSLinterfaceinthecircuit.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>circuitperfor
mancestatistics[15minute|24hour]command.
#show interfaces shdsl 1/0/1 circuit performance-statistcs 15-minute
SHDSL 1/0/1

IfId = 1

LTU
Current 15-Minute PM
10:15
ES

SES

UAS

CVC

LOSWS

ES

SES

UAS

CVC

LOSWS

NTU
Current 15-Minute PM
10:15

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-502

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42673

6TANV57CLI-35A

2-503

Total Access/NetVanta Carrier CLI Dictionary

show interfaces shdsl <shelf/slot/port> circuit performancestatistics 15-minute <1-96>


Usetheshowinterfacesshdsl*circuitperformancestatistics15minute*commandtodisplay
thehistoricalperformancemonitoringstatisticsforeachSHDSLinterfaceinthecircuit.Use
thissyntaxtoviewthe15minuteintervalperformancemonitoringdata.Usethissyntaxto
viewaspecifichistorical15minuteintervalorarangeofintervals.Upto96fifteenminute
intervalsaresupported.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>circuitperfor
mancestatistics15minute<196>command.
#show interfaces shdsl 1/0/1 circuit performance-statistcs 15-minute 1-2
SHDSL 1/0/1

IfId = 1

LTU
15-Minute PM (1)
10:15
ES

SES

UAS

CVC

LOSWS

ES

SES

UAS

CVC

LOSWS

ES

SES

UAS

CVC

LOSWS

LTU
15-Minute PM (2)
10:00

NTU
15-Minute PM (1)
10:15

NTU

2-504

6TANV57CLI-35A

Section 2, Commands - Common Commands

15-Minute PM (2)
10:00
ES

SES

UAS

CVC

LOSWS

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42675

6TANV57CLI-35A

2-505

Total Access/NetVanta Carrier CLI Dictionary

show interfaces shdsl <shelf/slot/port> circuit performancestatistics 24-hour <1-7>


Usetheshowinterfacesshdsl*circuitperformancestatistics24hour*commandtodisplay
thehistoricalperformancemonitoringstatisticsforeachSHDSLinterfaceinthecircuit.Use
thissyntaxtoviewthe24hourintervalperformancemonitoringdata.Usethissyntaxtoview
aspecifichistorical24hourintervalorarangeofintervals.Uptoseven24hourintervalsare
supported.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>circuitperfor
mancestatistics24hour<17>command.
#show interfaces shdsl 1/0/1 circuit performance-statistcs 24-hour 1-2
SHDSL 1/0/1

IfId = 1

LTU
24-Hour PM (1)
10:15
ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

LTU
24-Hour PM (2)
10:00

NTU
24-Hour PM (1)
10:15

NTU

2-506

6TANV57CLI-35A

Section 2, Commands - Common Commands

24-Hour PM (2)
10:00
ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42677

6TANV57CLI-35A

2-507

Total Access/NetVanta Carrier CLI Dictionary

show interfaces shdsl <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Usetheshowinterfacesshdsl*performancestatisticscommandtodisplayall96stored
intervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42664

2-508

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> performance-statistics


15-minute <1-96>
Usetheshowinterfacesshdsl*performancestatistics15minute*commandtodisplaya
specific15minuteintervalorarangeofintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>performance
statistics15minute<196>command.
#show interfaces shdsl 1/0/1 performance-statistcs 15-minute 1-2
SHDSL 1/0/1

IfId = 1

15-Minute PM (1)
10:15
ES

SES

UAS

CVC

LOSWS

ES

SES

UAS

CVC

LOSWS

SHDSL 1/0/1

IfId = 1

15-Minute PM (2)
10:00

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

6TANV57CLI-35A

2-509

Total Access/NetVanta Carrier CLI Dictionary

Command ID
42666

2-510

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> performance-statistics


24-hour <1-7>
Usetheshowinterfacesshdsl*performancestatistics24hour*commandtodisplayaspecific
24hourintervalorarangeofintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>performance
statistics24hour<17>command.
#show interfaces shdsl 1/0/1 performance-statistcs 24-hour 1-2
SHDSL 1/0/1

IfId = 1

24-Hour PM (1)
11/07
ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

ES

n/a

SES

n/a

UAS

n/a

CVC

n/a

LOSWS

n/a

SHDSL 1/0/1

IfId = 1

24-Hour PM (2)
11/06

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

6TANV57CLI-35A

2-511

Total Access/NetVanta Carrier CLI Dictionary

Command ID
42668

2-512

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> splice-detect 24-hour


Usetheshowinterfacesshdsl*splicedetect24hourcommandtodisplaythecurrent24hour
splicedetectdata.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>splicedetect
24hourcommand.
#show interfaces shdsl 1/0/1 splice-detect 24-hour
Current Splice Detect Data
Summary: Bad splice detected 390 (+/-195) feet
Distance(ft) Count
--------

-----

390

780

1170

1560

1950

2340

2730

3120

3510

3900

10

4290

11

4680

12

5070

13

5460

14

5850

15

6240

16

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-513

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42679

2-514

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces shdsl <shelf/slot/port> splice-detect 24-hour


<1-7>
Usetheshowinterfacesshdsl*splicedetect24hour*commandtodisplaythehistorical24
hoursplicedetectdata.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesshdsl<shelf/slot/port>splicedetect
24hour<17>command.
#show interfaces shdsl 1/0/1 splice-detect 24-hour 1-2
Interval 1 Splice Detect Data
Summary: Bad splice detected 780 (+/-195) feet
Distance(ft) Count
--------

-----

390

780

1170

1560

1950

2340

2730

3120

3510

3900

10

4290

11

4680

12

5070

13

5460

14

5850

15

6240

16

Interval 2 Splice Detect Data


Summary: Bad splice detected 1170 (+/-195) feet
Distance(ft) Count
--------

6TANV57CLI-35A

-----

390

780

1170

1560

2-515

Total Access/NetVanta Carrier CLI Dictionary

1950

2340

2730

3120

3510

3900

10

4290

11

4680

12

5070

13

5460

14

5850

15

6240

16

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42680

2-516

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


Usetheshowinterfacest1commandtodisplayconfigurationparameters,status,andcurrent
statisticsforaspecifiedT1port.

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest1[<shelf/slot/port>|<shelf/slot/
port:chan>]command.
#show interfaces t1 1/0/1
T1 1/0/1
Description

T1-E1 Port #1

State

Enabled - IS

Mode

T1

Operation

NTU

Link Status

Down

ESL

5880

ESP

SESP

10

UASP

5884

CVL

367848242

CVP

6704

Line Coding

B8ZS

Line Type

ESF

Loopback Timeout

30

BERT State

Disabled

Test Pattern

2^20

Send Code

No Remote Loop

LBO

LBO DS1 0db

CSU Loopback Enable

Disabled

NIU Loopback Enable

Disabled

FDL Loopback Enable

Disabled

Loopback

None

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

6TANV57CLI-35A

2-517

Total Access/NetVanta Carrier CLI Dictionary

Command ID
45707

2-518

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


performance-statistics 15-minute
Usetheshowinterfacest1performancestatistics15minutecommandtodisplayaspecific15
minuteinterval.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest1[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics15minutecommand.
#show interfaces t1 1/0/1 performance-statistcs 15-minute 1-2
T1 1/0/1
15-Minute PM (1)
16:00
ESL

ESP

SESP

UASP

CVL

CVP

ESL

ESP

SESP

UASP

CVL

CVP

T1 1/0/1
15-Minute PM (2)
15:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-519

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45710

2-520

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


performance-statistics 15-minute <1-96>
Usetheshowinterfacest1performancestatistics15minutecommandtodisplayaspecific15
minuteinterval.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest1[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics15minute<196>command.
#show interfaces t1 1/0/1 performance-statistcs 15-minute 1-2
T1 1/0/1
15-Minute PM (1)
16:00
ESL

ESP

SESP

UASP

CVL

CVP

ESL

ESP

SESP

UASP

CVL

CVP

T1 1/0/1
15-Minute PM (2)
15:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-521

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45711

2-522

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


performance-statistics 24-hour
Usetheshowinterfacest1performancestatistics24hourcommandtodisplayaspecific24
hourinterval.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest1[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics24hourcommand.
#show interfaces t1 1/0/1 performance-statistcs 24-hour 1-2
T1 1/0/1
24-Hour PM (1)
11/10
ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

T1 1/0/1
24-Hour PM (2)
11/09

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-523

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45712

2-524

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


performance-statistics 24-hour <1-7>
Usetheshowinterfacest1performancestatistics24hourcommandtodisplayaspecific24
hourinterval.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest1[<shelf/slot/port>|<shelf/slot/
port:chan>]performancestatistics24hour<17>command.
#show interfaces t1 1/0/1 performance-statistcs 24-hour 1-2
T1 1/0/1
24-Hour PM (1)
11/10
ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

ESL

n/a

ESP

n/a

SESP

n/a

UASP

n/a

CVL

n/a

CVP

n/a

T1 1/0/1
24-Hour PM (2)
11/09

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-525

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45713

2-526

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


realtime
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
45708

6TANV57CLI-35A

2-527

Total Access/NetVanta Carrier CLI Dictionary

show interfaces t3 <shelf/slot/port> performance-statistics [15minute|24-hour]


Syntax Description
<shelf/slot/port>

DisplayspecifiedT3port

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42686

2-528

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t3 <shelf/slot/port> performance-statistics 15minute <1-96>


Usetheshowinterfacest3performancestatistics15minutecommandtodisplayaspecific15
minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedT3port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest3<shelf/slot/port>performance
statistics15minute<196>command.
#show interfaces t3 1/0/1 performance-statistcs 15-minute 1-2
T3 1/0/1
15-Minute PM (1)
09:00
PES

PSES

SEFS

UAS

LCV

PCV

LES

CCV

CES

CSES

PES

PSES

SEFS

UAS

LCV

PCV

LES

CCV

CES

CSES

T3 1/0/1
15-Minute PM (2)
08:45

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-529

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42688

2-530

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t3 <shelf/slot/port> performance-statistics 24hour <1-7>


Usetheshowinterfacest3performancestatistics24hourcommandtodisplayaspecific24
hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedT3port

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacest3<shelf/slot/port>performance
statistics24hour<17>command.
#show interfaces t3 1/0/1 performance-statistcs 24-hour 1-2
T3 1/0/1
24-Hour PM (1)
06/07
PES

n/a

PSES

n/a

SEFS

n/a

UAS

n/a

LCV

n/a

PCV

n/a

LES

n/a

CCV

n/a

CES

n/a

CSES

n/a

PES

n/a

PSES

n/a

SEFS

n/a

UAS

n/a

LCV

n/a

PCV

n/a

LES

n/a

CCV

n/a

CES

n/a

CSES

n/a

T3 1/0/1
24-Hour PM (2)
06/06

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-531

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42690

2-532

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces t3 <shelf/slot/port> realtime


Syntax Description
<shelf/slot/port>

DisplayspecifiedT3port

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3)

Command ID
42685

6TANV57CLI-35A

2-533

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ten-gigabit-ethernet <shelf/slot/port>


[pluggable|realtime]
Usetheshowinterfacestengigabitethernetcommandtodisplayconfigurationparameters,
status,andcurrentstatisticsforaspecifiedTenGigabitEthernetport.

Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

pluggable

Pluggablemoduledata

realtime

Periodicallyupdateddisplay

Functional Notes
Showspecifictengigabitethernetinterfacestatus,PMect.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67099

2-534

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ten-gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usetheshowinterfacestengigabitethernet*performancestatisticscommandtodisplayall
96storedintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Functional Notes
ShowTenGigabitEthernet15min/24hourPMinlistformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67101

6TANV57CLI-35A

2-535

Total Access/NetVanta Carrier CLI Dictionary

show interfaces ten-gigabit-ethernet <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowinterfacestengigabitethernet*performancestatistics15minute*commandto
displaydatainaspecific15minuteinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

Functional Notes
ShowspecificTenGigabitEthernet15MinPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67103

2-536

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces ten-gigabit-ethernet <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowinterfacestengigabitethernet*performancestatistics24hour*commandto
displaydatainaspecific24hourinterval.

Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

Functional Notes
ShowspecificTenGigabitEthernet24hourPMinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67105

6TANV57CLI-35A

2-537

Total Access/NetVanta Carrier CLI Dictionary

show interfaces vdsl <shelf/slot/port> band-table


[downstream|upstream]
Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

downstream

Downstream

upstream

Upstream

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
91153

2-538

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> bit-allocation-table


[downstream|upstream]
Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

downstream

Downstream

upstream

Upstream

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
91151

6TANV57CLI-35A

2-539

Total Access/NetVanta Carrier CLI Dictionary

show interfaces vdsl <shelf/slot/port> performance-statistics


[15-minute|24-hour]
Usetheshowinterfacesvdsl<shelf/slot/port>performancestatistics[15minute|24hour]
commandtodisplaytheVDSL15minuteand24hourperformancemonitoringstatisticsin
listformat.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
40999

2-540

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> performance-statistics


15-minute [<1-96>|realtime]
Usetheshowinterfacesvdsl<shelf/slot/port>performancestatistics15minute[<1
96>|realtime]commandtodisplaythecurrentandhistoricalVDSL15minuteperformance
monitoringstatistics.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

15minute

Cumulativedatasincestartofinterval

<196>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>performance
statistics15minute[<196>|realtime]command.
>show interfaces vdsl 1/19/1 performance-statistics 15-minute 1
VDSL 1/19/1
15-Minute PM(1)
10:00:00
Downstream ES

Downstream SES

Downstream UAS

61

Downstream LOS

Downstream CBC

9610

Downstream UBC

Upstream ES

45

Upstream SES

15

Upstream UAS

73

Upstream LOL

Upstream LOS

Upstream CBC

336562

Upstream UBC

145

>

Functional Notes
NointervalspecifiedorintervalzeroreferstothecurrentPMinterval.Intervals1to96refer
tothepriorsequentialintervalsontheselectedintervalboundaries.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-541

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
41001

2-542

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> performance-statistics


15-minute <1-96> realtime
Usetheshowinterfacesvdsl<shelf/slot/port>performancestatistics15minute<196>
realtimecommandtodisplayfullscreenoutputforthecurrentVDSL15minuteperformance
monitoringstatisticsinrealtime.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

<196>

Rangeofhistoricalintervals

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>performance
statistics15minute<196>realtimecommand.
>show interfaces vdsl 1/19/1 performance-statistics 15-minute realtime
------------------------------------------------------------------------------VDSL 1/19/1
Current 15-Minute PM
Downstream ES

Downstream SES

Downstream UAS

Downstream LOS

Downstream CBC

3591

Downstream UBC

Upstream ES

Upstream SES

Upstream UAS

Upstream LOL

Upstream LOS

Upstream CBC

1791

Upstream UBC

------------------------------------------------------------------------------Exit - 'Ctrl-C', Freeze - 'f', Resume - 'r', Clear - 'c'

6TANV57CLI-35A

2-543

Total Access/NetVanta Carrier CLI Dictionary

Functional Notes
Informationiscontinuouslyupdatedontheconsoleuntileitherthedataisfrozen(bypressing
theFkey)orrealtimemodeisexited(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
45772

2-544

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> performance-statistics


24-hour [<1-7>|realtime]
Usetheshowinterfacesvdsl<shelf/slot/port>performancestatistics24hour[<17>|realtime]
commandtodisplaythecurrentVDSL24hourperformancemonitoringstatistics.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

24hour

Cumulativedatasincestartofinterval

<17>

Rangeofhistoricalintervals

realtime

Periodicallyupdateddisplay

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>performance
statistics24hour[<17>|realtime]command.
#show interfaces vdsl 1/19/1 performance-statistics 24-hour 1
VDSL 1/19/1
24-Hour PM(1)
02/09/09
Downstream ES

24

Downstream SES

22

Downstream UAS

120

Downstream LOS

Downstream CBC

47210

Downstream UBC

25

Upstream ES

53

Upstream SES

20

Upstream UAS

138

Upstream LOL

Upstream LOS

11

Upstream CBC

418613

Upstream UBC

163

Functional Notes
NointervalspecifiedorintervalzeroreferstothecurrentPMinterval.Intervals1to7referto
thepriorsequentialintervalsontheselectedintervalboundaries.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-545

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
41000

2-546

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> performance-statistics


24-hour <1-7> realtime
Usetheshowinterfacesvdsl<self/slot/port>performancestatistics24hour<17>realtime
commandtodisplayfullscreenoutputforthecurrent24hourintervalstatisticsinrealtime.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

<17>

Rangeofhistoricalintervals

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>performance
statistics24hour<17>realtimecommand.
#show interfaces vdsl 1/19/1 performance-statistics 24-hour realtime

------------------------------------------------------------------------------VDSL 1/19/1
Current 24-Hour PM
Downstream ES

24

Downstream SES

22

Downstream UAS

120

Downstream LOS

Downstream CBC

51526

Downstream UBC

25

Upstream ES

53

Upstream SES

20

Upstream UAS

138

Upstream LOL

Upstream LOS

11

Upstream CBC

419142

Upstream UBC

163

------------------------------------------------------------------------------Exit - 'Ctrl-C', Freeze - 'f', Resume - 'r', Clear - 'c'

6TANV57CLI-35A

2-547

Total Access/NetVanta Carrier CLI Dictionary

Functional Notes
Informationiscontinuouslyupdatedontheconsoleuntileitherthedataisfrozen(bypressing
theFkey)orrealtimemodeisexited(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
45770

2-548

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> realtime


Usetheshowinterfacesvdsl<shelf/slot/port>realtimecommandtodisplayfullscreenoutput
ofthecurrentstatusandperformancestatisticsforaspecifiedVDSLinterfaceandportinreal
time.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>realtime
command.
>show int vdsl 1/19/1 realtime
------------------------------------------------------------------------------VDSL 1/19/1
Service State

Out Of Service - Maintenance

Line Status

Up

Rate Mode

Adapt at startup

DMT Standard

993.2A (VDSL2 Region A)

Band Profile

8A

Est Length

236 ft-26ga

Up Time

939 sec
Downstream

Line Rate
Margin
Power
Attenuation
Max Attain Rate

81800 kbps

Upstream
6520 kbps

5.8 dB

5.8 dB

13.3 dBm

-3.3 dBm

0.8 dB

0.8 dB

83976 kbps

6615 kbps

Actual Delay

6.0 ms

7.0 ms

Actual INP

1.6 sym

2.3 sym

------------------------------------------------------------------------------Exit - 'Ctrl-C', Freeze - 'f', Resume - 'r', Clear - 'c'

Functional Notes
Informationiscontinuouslyupdatedontheconsoleuntileitherthedataisfrozen(bypressing
theFkey)orrealtimemodeisexited(bypressingCtrlC).

6TANV57CLI-35A

2-549

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
45764

2-550

6TANV57CLI-35A

Section 2, Commands - Common Commands

show interfaces vdsl <shelf/slot/port> snr-table upstream


Usetheshowinterfacesvdsl<shelf/slot/port>snrtableupstreamcommandtodisplaythe
measuredupstreamSNRpertonetableforaspecifiedVDSLinterface/port.Thistableliststhe
measuresignaltonoiseratioonapercarrierbasis(toneindex)indB.

Syntax Description
<shelf/slot/port>

DisplayspecifiedVdslport

Usage Examples
Thefollowingisasampleoutputoftheshowinterfacesvdsl<shelf/slot/port>snrtable
upstreamcommand.
>show int vdsl 1/19/1 snr-table upstream

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
96593

6TANV57CLI-35A

2-551

Total Access/NetVanta Carrier CLI Dictionary

show ip [access-lists|ntp|route]
Usetheshowip[accesslists|ntp|route]commandtodisplaycurrentinformationaboutthe
selectedIPservice.

Syntax Description
accesslists

ListIPaccesslists

ntp

DisplayNetworkTimeProtocolinformation

route

Displayroutetable

Usage Examples
Thefollowingisasampleoutputoftheshowip[accesslists|ntp|route]command.
! Output example of the access-lists option:
#show ip access-lists
IP Access List: List1
Num

IP/# NetMask Bits

1.

Empty

2.

Empty

3.

Empty

4.

Empty

5.

Empty

6.

Empty

7.

Empty

8.

Empty

9.

Empty

10.

Empty

11.

Empty

12.

Empty

13.

Empty

14.

Empty

15.

Empty

16.

Empty

Resource

#
! Output example of the ntp option:
#show ip ntp
Clock is not synchronized, stratum 16, no reference
reference time is 0.0 (not set)
clock offset is 0.00 msec, root delay is 0.00 msec, precision is 0 ppb
root dispersion is 0.00 msec, peer dispersion is 0.00 msec
#
! Output example of the route option:

2-552

6TANV57CLI-35A

Section 2, Commands - Common Commands

#show ip route
Total number of routes: 3
IP Address
1. 10.100.1.33
2. 10.100.11.138
3. 10.100.38.95

Netmask
255.255.255.0
255.255.255.0
255.255.255.0

Gateway

Ifc

None
10.100.11.254
10.100.38.254

Ethernet2 local
Inbnd
Ethernet

local
local

Functional Notes
UsetheaccesslistsoptiontodisplaythenameoftheprovisionedIPaccesslist,aswellas,the
IPaddressandnetmaskoftheprovisionedclients.
UsetherouteoptiontodisplaytheprovisionedIProutes.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
41360

6TANV57CLI-35A

2-553

Total Access/NetVanta Carrier CLI Dictionary

show ip access-lists WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64161

2-554

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp [evc|evc-map|groups|interface]


Usetheshowipigmp[groups|interface]commandtodisplaythecurrentstatusforthe
currentIGMPsessions.

Syntax Description
evc

EVC

evcmap

EVCmap

groups

DisplayIGMPgrouptable

interface

DisplayIGMPinterfaceinformation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),FIBERAM
(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1)

Command ID
41363

6TANV57CLI-35A

2-555

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc WORD <shelf/slot> performance-statistics


[15-minute|24-hour]
Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104889

2-556

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc WORD <shelf/slot> performance-statistics


15-minute <1-96>
UsetheshowipigmpevcWORD<shelf/slot>performancestatistics15minute<196>
commandtodisplaythe15minuteintervalsofIGMPPMstatisticsforaspecifiedEVCand
slot.

Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcWORD<shelf/slot>performance
statistics15minute<196>command.
>show ip igmp evc VIDEO performance-statistics 15-minute 10
EVC VIDEO on 1/5
15-min interval (02/10 11:15):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

33

Total number of joins received from users

Total number of successful joins from users

37

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

480

Total number of general queries received from network

14

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforEVCname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-557

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104891

2-558

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc WORD <shelf/slot> performance-statistics


24-hour <1-7>
UsetheshowipigmpevcWORDshelf/slotperformancestatistics24hour<17>commandto
displaythe24hourintervalsofIGMPPMstatisticsforaspecifiedEVCnameonaspecified
slot.

Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcWORD<shelf/slot>performance
statistics24hour<17>command.
>show ip igmp evc VIDEO performance-statistics 24-hour 1
EVC VIDEO on 1/5
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

962

Total number of joins received from users

Total number of successful joins from users

942

Total number of unsuccessful joins from users

Total number of leave messages sent to network

10

Total number of leave messages received from users

Total number of general queries sent to users

25120

Total number of general queries received from network

801

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforEVCname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-559

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104893

2-560

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc WORD <shelf/slot> realtime


UsetheshowipigmpevcWORD<shelf/slot>realtimecommandtodisplayfullscreenIGMP
informationforaspecifiedEVCnameandslotinrealtime.

Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcWORD<shelf/slot>realtime
command.
>show ip igmp evc VIDEO realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104888

6TANV57CLI-35A

2-561

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc WORD performance-statistics [15minute|24-hour]


Syntax Description
WORD

EVCname

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90051

2-562

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc WORD performance-statistics 15-minute <196>


UsetheshowipigmpevcWORDperformancestatistics15minute<196>commandto
displaythe15minuteintervalsofIGMPPMstatisticsforaspecifiedEVCnameforallslots.

Syntax Description
WORD

EVCname

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcWORDperformancestatistics15
minute<196>command.
>show ip igmp evc VIDEO performance-statistics 15-minute 10
EVC VIDEO on 1/5
15-min interval (02/10 11:15):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

33

Total number of joins received from users

Total number of successful joins from users

37

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

480

Total number of general queries received from network

14

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforEVCname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM

6TANV57CLI-35A

2-563

Total Access/NetVanta Carrier CLI Dictionary

(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90053

2-564

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc WORD performance-statistics 24-hour <17>


UsetheshowipigmpevcWORDperformancestatistics24hour<17>commandtodisplay
the24hourintervalsofIGMPPMstatisticsforaspecifiedEVCnameforallslots.

Syntax Description
WORD

EVCname

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcWORDperformancestatistics24
hour<17>command.
>show ip igmp evc VIDEO performance-statistics 24-hour 1
EVC VIDEO on 1/5
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

962

Total number of joins received from users

Total number of successful joins from users

942

Total number of unsuccessful joins from users

Total number of leave messages sent to network

10

Total number of leave messages received from users

Total number of general queries sent to users

25120

Total number of general queries received from network

801

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforEVCname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM

6TANV57CLI-35A

2-565

Total Access/NetVanta Carrier CLI Dictionary

(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90055

2-566

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp evc-map WORD <shelf/slot> performancestatistics [15-minute|24-hour]


Syntax Description
WORD

Entermapname

<shelf/slot>

Selectslot

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
83171

6TANV57CLI-35A

2-567

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc-map WORD <shelf/slot> performancestatistics 15-minute <1-96>


UsetheshowipigmpevcmapWORD<shelf/slot>performancestatistics15minute<196>
commandtodisplaythe15minuteintervalsofIGMPPMstatisticsforaspecifiedEVCMap
nameforaspecifiedshelf/slot.

Syntax Description
WORD

Entermapname

<shelf/slot>

Selectslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcmapWORD<shelf/slot>perfor
mancestatistics15minute<196>command.
>show ip igmp evc-map VIDEO25 1/5 performance-statistics 15-minute 10
EVC-Map VIDEO25 on 1/5
15-min interval (02/10 11:30):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

30

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

15

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforEVCMapname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-568

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
83173

6TANV57CLI-35A

2-569

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc-map WORD <shelf/slot> performancestatistics 24-hour <1-7>


UsetheshowipigmpevcmapWORD<shelf/slot>performancestatistics24hour<196>
commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecifiedEVCMap
nameforaspecifiedshelf/slot.

Syntax Description
WORD

Entermapname

<shelf/slot>

Selectslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcmapWORD<shelf/slot>perfor
mancestatistics24hour<17>command.
>show ip igmp evc-map VIDEO25 1/5 performance-statistics 24-hour 1
EVC-Map VIDEO25 on 1/5
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

942

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

785

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforEVCMapname

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-570

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
83175

6TANV57CLI-35A

2-571

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp evc-map WORD <shelf/slot> realtime


UsetheshowipigmpevcmapWORD<shelf/slot>realtimecommandtodisplayfullscreen
IGMPinformationforaspecifiedEVCMapnameforaspecifiedshelf/slotinrealtime.

Syntax Description
WORD

Entermapname

<shelf/slot>

Selectslot

Usage Examples
ThefollowingisasampleoutputoftheshowipigmpevcmapWORD<shelf/slot>realtime
command.
>show ip igmp evc-map VIDEO25 1/5 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
83155

2-572

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp groups <shelf/slot>


Usetheshowipigmpgroup<shelf/slot>commandtodisplaytheentireIGMPgrouptablefor
aspecifiedshelfandslot.

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpgroups<shelf/slot>command.
>show ip igmp groups 1/5
IGMP Connected Group Membership
Group Address
Reporter

Interface

Uptime

Expires

Last

225.1.1.9

evc VIDEO

16:15:28 00:00:00 127.0.0.2

225.1.1.9
10.13.110.177

evc-map VIDEO25

16:15:28 00:01:51

225.2.2.2

evc VIDEO

16:25:46 00:00:00 127.0.0.2

225.2.2.2
10.13.110.177

evc-map VIDEO25

16:25:46 00:01:50

>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),
ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
41372

6TANV57CLI-35A

2-573

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp groups <shelf/slot> A.B.C.D


Usetheshowipigmpgroups<shelf/slot>A.B.C.DcommandtofiltertheIGMPgrouptableby
IPaddressforaspecifiedshelfandslot.

Syntax Description
<shelf/slot>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpgroups<shelf/slot>A.B.C.Dcommand.
>show ip igmp groups 1/5 225.2.2.2
IGMP Connected Group Membership
Group Address
Reporter

Interface

Uptime

Expires

Last

225.2.2.2

evc VIDEO

16:27:06 00:00:00 127.0.0.2

225.2.2.2
10.13.110.177

evc-map VIDEO25

16:27:06 00:01:31

>

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),
ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
65936

2-574

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface [adsl|backplane|gigabit-ethernet|tengigabit-ethernet|vdsl]


UsetheshowipigmpinterfacecommandtoshowIGMPinterfaceinformationforallinter
faces

Syntax Description
interface

DisplayIGMPinterfaceinformation

adsl

ADSL

backplane

Internalbackplane

gigabitethernet

IEEE802.3

tengigabitethernet

TenGigabitEthernet

vdsl

VDSL

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterface[adsl|backplane|gigabit
ethernet|tengigabitethernet|vdsl]command.
>show ip igmp interface
Backplane 1/5/1
Network interface evc VIDEO is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Proxy
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 0.0.0.0
IGMP helper address is disabled
Current activity

Groups:

Total joins
Total joins from user

Hosts:

To Network: 2118

From Users:

Successful: 0

Unsuccessful: 0

Total leave messages

To Network: 10

From Users:

Total general queries

To Users:

From Network: 1379

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

...

6TANV57CLI-35A

2-575

Total Access/NetVanta Carrier CLI Dictionary

Functional Notes
ShowIGMPinterfaceinformation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),
ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
65925

2-576

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface adsl <shelf/slot/port> performancestatistics [15-minute|24-hour]


Syntax Description
<shelf/slot/port>

Selectalocation

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
83147

6TANV57CLI-35A

2-577

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface adsl <shelf/slot/port> performancestatistics 15-minute <1-96>


Usetheshowipigmpinterfaceadsl<shelf/slot/port>performancestatistics15minute<196>
commandtodisplaythe15minuteintervalsofIGMPPMstatisticsforaspecifiedADSLport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfaceadsl<shelf/slot/port>perfor
mancestatistics15minute<196>command.
>show ip igmp

interface adsl 1/17/25 performance-statistics 15-minute 10

ADSL 1/17/25
15-min interval (02/10 07:45):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

30

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

15

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforADSLport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

2-578

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
83149

6TANV57CLI-35A

2-579

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface adsl <shelf/slot/port> performancestatistics 24-hour <1-96>


Usetheshowipigmpinterfaceadsl<shelf/slot/port>performancestatistics24hour<17>
commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecifiedADSLport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfaceadsl<shelf/slot/port>perfor
mancestatistics24hour<196>command.
>show ip igmp interface adsl 1/17/25 performance-statistics 24-hour 1
ADSL 1/17/25
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

942

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

785

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforADSLport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

2-580

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
83151

6TANV57CLI-35A

2-581

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface adsl <shelf/slot/port> realtime


Usetheshowipigmpinterfaceadsl<shelf/slot/port>realtimecommandtodisplayfullscreen
IGMPinformationforaspecifiedADSLportinrealtime.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfaceadsl<shelf/slot/port>realtime
command.
>show ip igmp interface adsl 1/17/25 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
83146

2-582

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface backplane <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

Selectalocation

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83161

6TANV57CLI-35A

2-583

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface backplane <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowipigmpinterfacebackplane<shelf/slot/port>performancestatistics15minute
<196>commandtodisplaythe15minuteintervalsofIGMPPMstatisticsforaspecified
backplaneport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacebackplane<shelf/slot/port>
performancestatistics15minute<196>command.
>show ip igmp interface backplane 1/5/1 performance-statistics 15-minute
10
Backplane 1/5/1
15-min interval (02/10 08:30):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

30

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

15

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforbackplaneport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-584

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83163

6TANV57CLI-35A

2-585

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface backplane <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowipigmpinterfacebackplane<shelf/slot/port>performancestatistics24hour<1
7>commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecifiedbackplane
port.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacebackplane<shelf/slot/port>
performancestatistics24hour<17>command.
>show ip igmp

interface backplane 1/5/1 performance-statistics 24-hour 1

Backplane 1/5/1
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

962

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

10

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

801

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforbackplaneport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-586

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83165

6TANV57CLI-35A

2-587

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface backplane <shelf/slot/port> realtime


Usetheshowipigmpinterfacebackplane<shelf/slot/port>realtimecommandtodisplayfull
screenIGMPinformationforaspecifiedbackplaneportinrealtime.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacebackplane<shelf/slot/port>
realtimecommand.
>show ip igmp interface backplane 1/5/1 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83153

2-588

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

Selectalocation

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83156

6TANV57CLI-35A

2-589

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface gigabit-ethernet <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics15
minute<196>commandtodisplaythe15minuteintervalsofIGMPPMstatisticsfora
specifiedGigabitEthernetport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacegigabitethernet<shelf/slot/
port>performancestatistics15minute<196>command.
>show ip igmp interface gigabit -ethernet 1/A/1 performance-statistics
15-minute 10
Gigabit-Ethernet 1/A/1
15-min interval (02/10 08:30):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

30

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

15

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforGigabitEthernetport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-590

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83158

6TANV57CLI-35A

2-591

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface gigabit-ethernet <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowipigmpinterfacegigabitethernet<shelf/slot/port>performancestatistics24
hour<17>commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecified
GigabitEthernetport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacegigabitethernet<shelf/slot/
port>performancestatistics24hour<17>command.
>show ip igmp
24-hour 1

interface gigabit-ethernet 1/A/1 performance-statistics

Gigabit-Ethernet 1/A/1
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

962

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

10

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

801

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforGigabitEthernetport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-592

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83160

6TANV57CLI-35A

2-593

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface gigabit-ethernet <shelf/slot/port>


realtime
Usetheshowipigmpinterfacegigabitethernet<shelf/slot/port>realtimecommandto
displayfullscreenIGMPinformationforaspecifiedGigabitEthernetportinrealtime.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacegigabitethernet<shelf/slot/
port>realtimecommand.
>show ip igmp interface gigabit-ethernet 1/A/1 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83152

2-594

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface ten-gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

Selectalocation

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94287

6TANV57CLI-35A

2-595

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface ten-gigabit-ethernet <shelf/slot/port>


performance-statistics 15-minute <1-96>
Usetheshowipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics
15minute<196>commandtodisplaythe15minuteintervalsofIGMPPMstatisticsfora
specified10GigabitEthernetport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacetengigabitethernet<shelf/
slot/port>performancestatistics15minute<196>command.
>show ip igmp interface ten-gigabit -ethernet 1/A/1 performancestatistics 15-minute 10
10 Gigabit-Ethernet 1/A/1
15-min interval (02/10 08:30):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

30

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

15

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsfor10GigabitEthernetport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-596

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94289

6TANV57CLI-35A

2-597

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface ten-gigabit-ethernet <shelf/slot/port>


performance-statistics 24-hour <1-7>
Usetheshowipigmpinterfacetengigabitethernet<shelf/slot/port>performancestatistics
24hour<17>commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecified
10GigabitEthernetport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacetengigabitethernet<shelf/
slot/port>performancestatistics24hour<17>command.
>show ip igmp interface ten-gigabit-ethernet 1/A/1 performancestatistics 24-hour 1
10 Gigabit-Ethernet 1/A/1
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

962

Total number of joins received from users

Total number of successful joins from users

Total number of unsuccessful joins from users

Total number of leave messages sent to network

10

Total number of leave messages received from users

Total number of general queries sent to users

Total number of general queries received from network

801

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsfor10GigabitEthernetport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-598

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94291

6TANV57CLI-35A

2-599

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface ten-gigabit-ethernet <shelf/slot/port>


realtime
Usetheshowipigmpinterfacetengigabitethernet<shelf/slot/port>realtimecommandto
displayfullscreenIGMPinformationforaspecified10GigabitEthernetportinrealtime.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacetengigabitethernet<shelf/
slot/port>realtimecommand.
>show ip igmp interface ten-gigabit-ethernet 1/A/1 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94286

2-600

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip igmp interface vdsl <shelf/slot/port> performancestatistics [15-minute|24-hour]


Syntax Description
<shelf/slot/port>

Selectalocation

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
83166

6TANV57CLI-35A

2-601

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface vdsl <shelf/slot/port> performancestatistics 15-minute <1-96>


Usetheshowipigmpinterfacevdsl<shelf/slot/port>performancestatistics15minute<196>
commandtodisplaythe15minuteintervalsofIGMPPMstatisticsforaspecifiedVDSLport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacevdsl<shelf/slot/port>perfor
mancestatistics15minute<196>command.
>show ip igmp

interface vdsl 1/5/25 performance-statistics 15-minute 10

VDSL 1/5/25
15-min interval (02/10 07:45):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

30

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

15

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
15minuteintervalIGMPPMstatisticsforVDSLport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

2-602

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
83168

6TANV57CLI-35A

2-603

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface vdsl <shelf/slot/port> performancestatistics 24-hour <1-7>


Usetheshowipigmpinterfacevdsl<shelf/slot/port>performancestatistics24hour<17>
commandtodisplaythe24hourintervalsofIGMPPMstatisticsforaspecifiedVDSLport.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacevdsl<shelf/slot/port>perfor
mancestatistics24hour<17>command.
>show ip igmp interface vdsl 1/5/25 performance-statistics 24-hour 1
VDSL 1/5/25
24-hr interval (02/09 10:56):
Current number of active groups

Total number of active hosts

Total number of joins sent to network

Total number of joins received from users

Total number of successful joins from users

942

Total number of unsuccessful joins from users

Total number of leave messages sent to network

Total number of leave messages received from users

Total number of general queries sent to users

785

Total number of general queries received from network

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
24hourintervalIGMPPMstatisticsforVDSLport

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

2-604

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
83170

6TANV57CLI-35A

2-605

Total Access/NetVanta Carrier CLI Dictionary

show ip igmp interface vdsl <shelf/slot/port> realtime


Usetheshowipigmpinterfacevdsl<shelf/slot/port>realtimecommandtodisplayfullscreen
IGMPinformationforaspecifiedVDSLportinrealtime.

Syntax Description
<shelf/slot/port>

Selectalocation

Usage Examples
Thefollowingisasampleoutputoftheshowipigmpinterfacevdsl<shelf/slot/port>realtime
command.
>show ip igmp interface vdsl 1/5/25 realtime

Functional Notes
Usetherealtimeargumentforthiscommandtodisplayfullscreenoutputinrealtime.Infor
mationiscontinuouslyupdatedontheconsoleuntilyoueitherfreezethedata(bypressing
theFkey)orexitrealtimemode(bypressingCtrlC).

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
83154

2-606

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ip ntp associations


UsetheshowipntpassociationscommandtoviewactiveNTPserverassociations.

Usage Examples
Thefollowingisasampleoutputoftheshowipntpassociationscommand.
#shos ip ntp associations
address

ref clock

st

when

poll reach

delay

offset

2.60

1.22

disp
+P10.44.4.42
0.03

.PPS.

16

377

+ selected, - candidate, ~ configured, P preferred

Functional Notes
NTPassociationitems:
1)addressaddressoftheNTPserver
2)refclockThesourceoftheclockusedbytheNTPserver(couldbeanIPaddressora
namei.ePPS)
3)st(SrvStratum)ThestratumoftheNTPserver.
4)when(SrvTimeSinceLastRx)ThenumberofsecondssincethelastpolltotheNTPserver.
5)poll(for(intj=0;j<NCS.Servers[i].SrvLog2PollRate;j++)poll*=2;)Therateinsecondsat
whichtheNTPserverispolled.
6)reach(SrvReachability)AnoctalnumberthatrepresentsthenumberofsuccessfulNTP
serverpolls.
7)delay(SrvPeerDelaySeconds,SrvPeerDelaySubSeconds)Theroundtripdelaytothe
NTPserverinmilliseconds.
8)offset(SrvOffsetSeconds,SrvOffsetSubSeconds)ThedifferenceintimebetweentheNTP
serverandthelocalsystemclockinmilliseconds
9)disp(SrvPeerDispersionSeconds,SrvPeerDispersionSubSeconds)?themaximum
differencebetweenthelocalsystemclockandtheNTPserverinmilliseconds

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

6TANV57CLI-35A

2-607

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46508

2-608

6TANV57CLI-35A

Section 2, Commands - Common Commands

show lacp [<shelf/slot>|system-id]


TheshowlacpsystemidcommanddisplaystheLinkAggregationControlProtocolsystemid
.Theshowlacp<shelf/slot>commanddisplaysthedetailedLACPinformationforthe
specifiedshelf/slot.

Syntax Description
<shelf/slot>

Displaydetailedinfoforshelf/slot

systemid

DisplaysystemID

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
88236

6TANV57CLI-35A

2-609

Total Access/NetVanta Carrier CLI Dictionary

show lacp <shelf/slot> [counters|states|summary]


Theshowlacp<shelf/slot>[counters|states|summary]commanddisplaysthespecified
LACPstatisticsforthedesired<shelf/slot>.

Syntax Description
<shelf/slot>

Displaydetailedinfoforshelf/slot

counters

Displaycounters

states

Displaystateinfo

summary

Displaysummaryinfo

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
88237

2-610

6TANV57CLI-35A

Section 2, Commands - Common Commands

show lacp interface gigabit-ethernet <shelf/slot/port>


[states|summary]
Theshowlacpinterfacegigabitethernet<shelf/slot/port>[states|summary]command
displaysthespecifiedLACPstatisticsassociatedwiththedesiredgigabitethernetport.

Syntax Description
<shelf/slot/port>

Displaydetailedinfoforthisinterface

states

Displaystateinfo

summary

Displaysummaryinfo

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
88244

6TANV57CLI-35A

2-611

Total Access/NetVanta Carrier CLI Dictionary

show lacp interface lag-group <shelf/slot/group>


[states|summary]
Theshowlacpinterfacelaggroup<shelf/slot/groupid>[states|summary]commanddisplays
thedesiredLACPstatisticsassociatedwiththespecifiedlinkaggregationgroupid.

Syntax Description
<shelf/slot/group>

DisplayspecifiedLAGgroup

states

Displaystateinfo

summary

Displaysummaryinfo

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
88252

2-612

6TANV57CLI-35A

Section 2, Commands - Common Commands

show lacp interface ten-gigabit-ethernet <shelf/slot/port>


[states|summary]
Syntax Description
<shelf/slot/port>

Displaydetailedinfoforthisinterface

states

Displaystateinfo

summary

Displaysummaryinfo

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
88248

6TANV57CLI-35A

2-613

Total Access/NetVanta Carrier CLI Dictionary

show line console <0>


Usetheshowlineconsole0commandtoviewthecurrentstatusoftheconsoleport.

Usage Examples
Thefollowingisasampleoutputoftheshowlineconsole<0>command.
#show line console 0
RS232 Interfaces...
RS232 1

IfId = 13

Provisioned Baud Rate

Auto

Functional Baud Rate

115200

Data Bits

Parity

None

Stop Bits

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
78140

2-614

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac [address-table|limits]


Usetheshowmacaddresstablecommandtodisplayallstaticanddynamicentriesinthe
mediumaccesscontrol(MAC)addresstableforallvirtuallocalareanetworks(VLANs)and
physicalinterfaces.Usetheshowmaclimitscommandtodisplaythecurrentconfiguration
andstatusofMAClimiting.Ifthelimitisreached,nonewaddressesarelearnedand
incomingtrafficthatisnotintheMACtablewillnotbeadmitted.

Syntax Description
addresstable

DisplayMACaddresstableentries

limits

Tabledisplayingnumberlearnedandlimitperport

Usage Examples
Thefollowingisasampleoutputoftheshowmac[addresstable|limits]command.
#show mac address-table
MAC-Address

Port

VLAN

00:A0:C8:30:62:67

Ethernet 1/0/1

99

#show mac limits


Port

Max Allowed Current Learned

Ethernet 1/0/1

100

Ethernet 1/0/2

Disabled

Ethernet 1/0/3

Disabled

Ethernet 1/0/4

Disabled

Gigabit Ethernet 1/0/1 Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),ADSL2AM(1187101E1),
ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),GPONAM
(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE

6TANV57CLI-35A

2-615

Total Access/NetVanta Carrier CLI Dictionary

(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45789

2-616

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table <shelf/slot> [agingtime|count|dynamic|multicast|static]


Usetheshowmacaddresstable<shelf/slot>[count|dynamic|static]commandtodisplayall
staticanddynamicentriesinthemediumaccesscontrol(MAC)addresstableforallEVCsand
physicalinterfacesforagivenshelfandslot.

Syntax Description
<shelf/slot>

Selectalocation

agingtime

DisplaytheMACaddresstableagingtime

count

DisplaytheMACaddresstablecount

dynamic

DisplayalldynamicentriesintheMACaddresstable

multicast

DisplayallmulticastentriesintheMACaddresstable

static

DisplayallstaticentriesintheMACaddresstable

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),ADSL2AM(1187101E1),
ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),GPONAM
(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SM10GE
(1187025G2)

Command ID
78213

6TANV57CLI-35A

2-617

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table <shelf/slot> dynamic s-tag <1-4094>


Usetheshowmacaddresstable<shelf/slot>dynamicstag<14094>commandtodisplayall
thedynamicMACaddresstableentriesonthespecifiedshelf/slotandstag.

Syntax Description
<shelf/slot>

Selectalocation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),
ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder
(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77911

2-618

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table <shelf/slot> evc WORD


Usetheshowmacaddresstable<shelf/slot>stag<14094>commandtodisplayallthe
mediumaccesscontrol(MAC)addresstableentriesonthespecifiedshelf/slotandstag.

Syntax Description
<shelf/slot>

Selectalocation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101727

6TANV57CLI-35A

2-619

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table <shelf/slot> s-tag <1-4094>


Usetheshowmacaddresstable<shelf/slot>stag<14094>commandtodisplayallthe
mediumaccesscontrol(MAC)addresstableentriesonthespecifiedshelf/slotandstag.

Syntax Description
<shelf/slot>

Selectalocation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77915

2-620

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table <shelf/slot> static s-tag <1-4094>


Usetheshowmacaddresstable<shelf/slot>staticstag<14094>commandtodisplayallthe
staticmediumaccesscontrol(MAC)addresstableentriesonthespecifiedshelf/slotandstag.

Syntax Description
<shelf/slot>

Selectalocation

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),
ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder
(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77913

6TANV57CLI-35A

2-621

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table dynamic interface backplane <shelf/


slot/port>
Usethiscommandtodisplayallthedynamicmediumaccesscontrol(MAC)addresstable
entriesonthespecidedbackplaneinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77902

2-622

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table dynamic interface gigabit-ethernet


<shelf/slot/port>
Usethiscommandtodisplayallthedynamicmediumaccesscontrol(MAC)addresstable
entriesonthespecidedgigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77898

6TANV57CLI-35A

2-623

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table dynamic interface muxponderhighspeed <shelf/slot/port>


Usethiscommandtodisplayallthedynamicmediumaccesscontrol(MAC)addresstable
entriesonthespecifiedMuxponderhighspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153912

2-624

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table dynamic interface muxpondermidspeed <shelf/slot/port>


Usethiscommandtodisplayallthedynamicmediumaccesscontrol(MAC)addresstable
entriesonthespecifiedMuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153910

6TANV57CLI-35A

2-625

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table dynamic interface ten-gigabitethernet <shelf/slot/port>


Usethiscommandtodisplayallthedynamicmediumaccesscontrol(MAC)addresstable
entriesonthespecidedtengigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77900

2-626

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table interface backplane <shelf/slot/port>


Usethiscommandtodisplayallthemediumaccesscontrol(MAC)addresstableentrieson
thespecidedbackplaneinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
77886

6TANV57CLI-35A

2-627

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table interface gigabit-ethernet <shelf/slot/


port>
Usethiscommandtodisplayallthemediumaccesscontrol(MAC)addresstableentrieson
thespecidedgigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77884

2-628

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table interface muxponder-highspeed


<shelf/slot/port>
Usethiscommandtodisplayallthemediumaccesscontrol(MAC)addresstableentrieson
thespecifiedMuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153920

6TANV57CLI-35A

2-629

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table interface muxponder-midspeed


<shelf/slot/port>
Usethiscommandtodisplayallthemediumaccesscontrol(MAC)addresstableentrieson
thespecifiedMuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153918

2-630

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table interface ten-gigabit-ethernet <shelf/


slot/port>
Usethiscommandtodisplayallthemediumaccesscontrol(MAC)addresstableentrieson
thespecidedtengigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77885

6TANV57CLI-35A

2-631

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table static interface backplane <shelf/slot/


port>
Usethiscommandtodisplayallthestaticmediumaccesscontrol(MAC)addresstableentries
onthespecidedbackplaneinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77909

2-632

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table static interface gigabit-ethernet


<shelf/slot/port>
Usethiscommandtodisplayallthestaticmediumaccesscontrol(MAC)addresstableentries
onthespecidedgigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77905

6TANV57CLI-35A

2-633

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table static interface muxponderhighspeed <shelf/slot/port>


Usethiscommandtodisplayallthestaticmediumaccesscontrol(MAC)addresstableentries
onthespecifiedMuxponderhighspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153916

2-634

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mac address-table static interface muxponder-midspeed


<shelf/slot/port>
Usethiscommandtodisplayallthestaticmediumaccesscontrol(MAC)addresstableentries
onthespecifiedMuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153914

6TANV57CLI-35A

2-635

Total Access/NetVanta Carrier CLI Dictionary

show mac address-table static interface ten-gigabit-ethernet


<shelf/slot/port>
Usethiscommandtodisplayallthestaticmediumaccesscontrol(MAC)addresstableentries
onthespecidedtengigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
77907

2-636

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu [configuration|status]


Usetheshowmenu[configuration|status]commandtoviewconfigurationorstatusinfor
mationinaformatsimilartolegacyVT100menus.

Syntax Description
configuration

Configurationmenu

status

Statusmenu

Usage Examples
Thefollowingisasampleoutputoftheshowmenu[configuration|status]command.
#show menu configuration
ADTRAN
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
--------------------- For Information or Technical Support ------------------Support Hours ( Normal 7am - 7pm CST, Emergency 7 days x 24 hours )
Phone: 800.726.8663 / 888.873.HDSL
www.adtran.com

Fax: 256.963.6217

Internet:

-----------------------------------------------------------------------------ADTRAN NetVanta838
Part Number: 1200633G4
Serial Number: Not Set
CLEI: Not Set
App Code Version: B02.12
App Code Checksum: 1252977A
Boot Code Version: A01
Boot Code Checksum: 02EF9501
MAC Address: 00:A0:C8:05:03:ED
Product Revision: A
IP Address: 10.100.42.69
Subnet Mask: 255.255.255.0
Gateway: 10.100.42.254
Management VLAN ID: 100
Management Ports: Ethernet

1/0/1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

6TANV57CLI-35A

2-637

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77964

2-638

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu performance-statistics e1 <shelf/slot/port> [15minute|24-hour]


Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
100353

6TANV57CLI-35A

2-639

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics ethernet <shelf/slot/port>


[15-minute|24-hour]
Usetheshowmenuperformancestatisticsethernet<shelf/slot/port>[15minute|24hour]
commandtoviewhistoricalEthernetperformancedatainaformatsimilartolegacyVT100
menus.

Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Usage Examples
Thefollowingisasampleoutputoftheshowmenuperformancestatisticsethernet<shelf/
slot/port>[15minute|24hour]command.
#show menu performance-statistics ethernet 1/0/1 15-minute
15 Minute Ethernet Port 1 Performance Data
____

_____

| CO |

SHDSL

| NTE |

|<------------------1>|

|-Eth1->

|<------------------2>|

|-Eth2->

|<------------------3>|

|-Eth3->

|<------------------4>|

|-Eth4->

|<------------------5>|

|<------------------6>|

|-GigE->

|<------------------7>|

|<------------------8>|

|____|

|_____|
RxDiscard

TxBytes

TxPackets

09:45

RxBytes
74459

RxPackets RxCrcAlign
547

2616

27

09:30

156821

1169

09:15

154289

1132

09:00

135943

1003

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-640

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77985

6TANV57CLI-35A

2-641

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics gigabit-ethernet <shelf/slot/


port> [15-minute|24-hour]
Usetheshowmenuperformancestatisticsgigabitethernet<shelf/slot/port>[15minute|24
hour]commandtoviewhistoricalGigabitEthernetperformancedatainaformatsimilarto
legacyVT100menus.

Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Usage Examples
Thefollowingisasampleoutputoftheshowmenuperformancestatisticsgigabitethernet
<shelf/slot/port>[15minute|24hour]command.
#show menu performance-statistics gigabit-ethernet 1/0/1 15-minute
15 Minute Gig-E Port 1 Performance Data
____

_____

| CO |

SHDSL

| NTE |

|<------------------1>|

|-Eth1->

|<------------------2>|

|-Eth2->

|<------------------3>|

|-Eth3->

|<------------------4>|

|-Eth4->

|<------------------5>|

|<------------------6>|

|-GigE->

|<------------------7>|

|<------------------8>|

|____|

|_____|
RxDiscard

TxBytes

TxPackets

09:45

RxBytes
0

RxPackets CRC Errors


0

09:30

09:15

09:00

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-642

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77989

6TANV57CLI-35A

2-643

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics hdsl2 <shelf/slot/port> [15minute|24-hour]


Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
86827

2-644

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu performance-statistics hdsl4 <shelf/slot/port> [15minute|24-hour]


Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
86831

6TANV57CLI-35A

2-645

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics shdsl <shelf/slot/port> [15minute|24-hour]


Usetheshowmenuperformancestatisticsshdsl<shelf/slot/port>[15minute|24hour]
commandtoviewhistoricalSHDSLperformancedatainaformatsimilartolegacyVT100
menus.

Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Usage Examples
Thefollowingisasampleoutputoftheshowmenuperformancestatisticsshdsl<shelf/slot/
port>[15minute|24hour]command.
#show menu performance-statistics shdsl 1/0/1 15-minute
15 Minute SHDSL Port 1 Performance Data
____

_____

| CO |

SHDSL

| NTE |

|<------------------1>|

|-Eth1->

|<------------------2>|

|-Eth2->

|<------------------3>|

|-Eth3->

|<------------------4>|

|-Eth4->

|<------------------5>|

|<------------------6>|

|-GigE->

|<------------------7>|

|<------------------8>|

|____|

|_____|

ES SES UAS LOSWS

CVC

09:45

09:30

09:15

09:00

41

41

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-646

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV
838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA
838(1200633G7)

Command ID
77993

6TANV57CLI-35A

2-647

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics t1 [<shelf/slot/port>|<shelf/


slot/port:chan>] 15-minute
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
78002

2-648

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu performance-statistics t1 [<shelf/slot/port>|<shelf/


slot/port:chan>] 24-hour
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
78003

6TANV57CLI-35A

2-649

Total Access/NetVanta Carrier CLI Dictionary

show menu performance-statistics t3 <shelf/slot/port> [15minute|24-hour]


Syntax Description
15minute

All15minuteintervals

24hour

All24hourintervals

Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV873(1200639G1)

Command ID
77997

2-650

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu provisioning e1 <shelf/slot/port>


Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
100357

6TANV57CLI-35A

2-651

Total Access/NetVanta Carrier CLI Dictionary

show menu provisioning ethernet <shelf/slot/port>


Usethiscommandtoshowanethernetportsprovisioninginamenulikeformat.

Usage Examples
Thefollowingisasampleoutputoftheshowmenuprovisioningethernet<shelf/slot/port>
command.
#show menu provisioning ethernet 1/0/1
Ethernet Port 1 Provisioning
Description

Eth Port #1

State

Enabled - IS

Rate & Duplex

Auto

Cross-Over Mode

Auto

Link State Awareness

Disabled

Ethernet Port 1 Alarm Thresholds


15 Min CRC & Align Err

Disabled

15 Min Runt Pkt

Disabled

15 Min Giant Pkt

Disabled

15 Min Collision

Disabled

15 Min Discard

Disabled

Daily

CRC & Align Err

Disabled

Daily

Runt Pkt

Disabled

Daily

Giant Pkt

Disabled

Daily

Collision

Disabled

Daily

Discard

Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77968

2-652

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu provisioning gigabit-ethernet <shelf/slot/port>


Usethiscommandtoshowagigabitethernetportsprovisioninginamenulikeformat.

Usage Examples
Thefollowingisasampleoutputoftheshowmenuprovisioninggigabitethernet<shelf/slot/
port>command.
#show menu provisioning gigabit-ethernet 1/0/1
Gigabit Ethernet Port 1 Provisioning
Description

GigEth Port #1

State

Enabled - IS

Link State Awareness

Disabled

Gigabit Ethernet Port 1 Alarm Thresholds


15 Min CRC Error

Disabled

15 Min Discard

Disabled

15 Min Giant Pkt

Disabled

15 Min Runt Pkt

Disabled

Daily

CRC Error

Disabled

Daily

Discard

Disabled

Daily

Giant Pkt

Disabled

Daily

Runt Pkt

Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77970

6TANV57CLI-35A

2-653

Total Access/NetVanta Carrier CLI Dictionary

show menu provisioning hdsl2 <shelf/slot/port>


UsethiscommandtoshowaHDSL2portsprovisioninginamenulikeformat.

Usage Examples
Thefollowingisasampleoutputoftheshowmenuprovisioninghdsl2<shelf/slot/port>
command.
#show menu provisioning hdsl2 1/0/1
HDSL2 Port 1 Provisioning
Description

HDSL2 Port #1

State

Enabled - IS

Loopback

No Loop

NIU Loopback

Enabled

Loopback Timeout

120 Minutes

Bonding Group

HDSL2 Port 1 Alarm Thresholds


SNR Margin

Disabled

Loop Attenuation

Disabled

15 Min ES

Disabled

15 Min SES

Disabled

15 Min UAS

Disabled

Daily

ES

Disabled

Daily

SES

Disabled

Daily

UAS

Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
86823

2-654

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu provisioning hdsl4 <shelf/slot/port>


UsethiscommandtoshowaSHDSLportsprovisioninginamenulikeformat.

Usage Examples
Thefollowingisasampleoutputoftheshowmenuprovisioninghdsl4<shelf/slot/port>
command.
#show menu provisioning hdsl4 1/0/1
HDSL4 Port 1 Provisioning
Description

= HDSL4 Port #1

State

Enabled - IS

Loopback

No Loop

NIU Loopback

Enabled

Loopback Timeout

Disabled

Bonding Group

HDSL4 Port 1 Alarm Thresholds


SNR Margin

Disabled

Loop Attenuation

Disabled

15 Min ES

Disabled

15 Min SES

Disabled

15 Min UAS

Disabled

Daily

ES

Disabled

Daily

SES

Disabled

Daily

UAS

Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV844(1200635G2)

Command ID
86825

6TANV57CLI-35A

2-655

Total Access/NetVanta Carrier CLI Dictionary

show menu provisioning shdsl <shelf/slot/port>


UsethiscommandtoshowaSHDSLportsprovisioninginamenulikeformat.

Usage Examples
Thefollowingisasampleoutputoftheshowmenuprovisioningshdsl<shelf/slot/port>
command.
#show menu provisioning shdsl 1/0/1
SHDSL Port 1 Provisioning
Description

SHDSL Port #1

State

Enabled - IS

Rate Mode

Fixed

Rate

192-5696 kbps

PBO (dB)

Disabled

Annex

A/B

Bonding Group

SHDSL Port 1 Alarm Thresholds


SNR Margin

Disabled

Loop Attenuation

Disabled

15 Min ES

Disabled

15 Min SES

Disabled

15 Min UAS

Disabled

15 Min CVC

Disabled

15 Min LOSWS

Disabled

Daily

ES

Disabled

Daily

SES

Disabled

Daily

UAS

Disabled

Daily

CVC

Disabled

Daily

LOSWS

Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV
838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA
838(1200633G7)

2-656

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
77972

6TANV57CLI-35A

2-657

Total Access/NetVanta Carrier CLI Dictionary

show menu provisioning t1 <shelf/slot/port>


Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
77980

2-658

6TANV57CLI-35A

Section 2, Commands - Common Commands

show menu provisioning t3 <shelf/slot/port>


Functional Notes
ThesecommandsareusedbytheNCTEtodisplayinformationinaformatsimilartolegacy
menus.ThesecommandswillneedtoremaininplaceuntilthesystemhascompletedCLI
convergence.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV873(1200639G1)

Command ID
77978

6TANV57CLI-35A

2-659

Total Access/NetVanta Carrier CLI Dictionary

show menu status detail


Usetheshowmenustatusdetailedcommandtooutputthedetailedstatusscreen.

Usage Examples
Thefollowingisasampleoutputoftheshowmenustatusdetailcommand.
#show menu status detail
SHDSL Interface Data
Port 1

Port 2

Port 3

Port 4

-------- -------- -------- -------MGN(CUR/MIN/MAX): 19/19/19 19/19/19 19/19/19 19/19/19


ATN(CUR/MIN/MAX): 00/00/00 00/00/00 00/00/00 00/00/00
US/DS PBO:

00/00

00/00

00/00

00/00

ES 15MIN:

SES 15MIN:

UAS 15MIN:

CVC 15MIN:

LOSWS 15MIN:

Port 5

Port 6

Port 7

Port 8

-------- -------- -------- -------MGN(CUR/MIN/MAX): 19/19/19 19/19/19 19/18/19 18/18/18


ATN(CUR/MIN/MAX): 00/00/00 00/00/00 00/00/00 00/00/00
US/DS PBO:

00/00

00/00

00/00

00/00

ES 15MIN:

SES 15MIN:

UAS 15MIN:

CVC 15MIN:

LOSWS 15MIN:

Ethernet Interface Data


Gig-E

Eth 1

Eth 2

Eth 3

Eth 4

---------- ---------- ---------- ---------- ---------

2-660

Link Status:

Up

Up

Down

Down

Down

Rate & Duplex:

N/A

100, Full

N/A

N/A

N/A

Rx Bytes:

2788

0
0

Rx Packets:

41

Rx CRC & Align Errors:

Rx Runt Packets:

Rx Giant Packets:

Rx Discarded Frames:

Collisions:

N/A

Tx Bytes:

2788

Tx Packets:

41

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
77982

6TANV57CLI-35A

2-661

Total Access/NetVanta Carrier CLI Dictionary

show mevc WORD


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136013

2-662

6TANV57CLI-35A

Section 2, Commands - Common Commands

show mevc WORD <shelf/slot>


Syntax Description
WORD

DisplayspecifiedMEVC

Functional Notes
Usetheshowmevc?WORD<shelf/slot>commandtodisplay?configurationparametersand
thecurrentstatusforthespecifiedMEVC.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
138532

6TANV57CLI-35A

2-663

Total Access/NetVanta Carrier CLI Dictionary

show muxponder-ethernet <shelf/slot> qos [cosmap|untagged]


Syntax Description
<shelf/slot>

Specifiedslot

cosmap

DisplaythemapoftheLayer2ClassofService(CoS)valueto
eachqueue

untagged

Displaythequeuethatuntaggedframesegressinto

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
147347

2-664

6TANV57CLI-35A

Section 2, Commands - Common Commands

show node-information statistics


UsetheshowshdslcommandtodisplaySHDSLconfigurationandstatistics.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
153904

6TANV57CLI-35A

2-665

Total Access/NetVanta Carrier CLI Dictionary

show peer default ip dhcp-client lease interface ppp-group


<shelf/slot/group>
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104345

2-666

6TANV57CLI-35A

Section 2, Commands - Common Commands

show policer WORD <shelf/slot>


UsetheshowpolicerWORD<shelf/slot>commandtodisplayconfigurationparametersand
currentstatusforthespecifiedpolicer.

Syntax Description
WORD

Displayspecifiedpolicer

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1)

Command ID
90195

6TANV57CLI-35A

2-667

Total Access/NetVanta Carrier CLI Dictionary

show policer WORD performance-statistics [15-minute|24hour]


Usetheshowpolicerperformancestatisticscommandtodisplaythecurrent15minuteor24
hourinterval.

Syntax Description
WORD

Displayspecifiedpolicer

15minute

Cumulativedatasincestartofinterval

24hour

Cumulativedatasincestartofinterval

Usage Examples
ThefollowingisasampleoutputoftheshowpolicerWORDperformancestatistics[15
minute|24hour]command.
#show policer POL1 performance-statistics 15-minute
Policer POL1
Current 15-Minute PM
00:15
Ingress Green Frames

Ingress Green Bytes

Ingress Yellow Frames

Ingress Yellow Bytes

Ingress Red Frames

Ingress Red Bytes

Green Frame Discards

Green Octet Discards

Yellow Frame Discards

Yellow Octet Discards

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-668

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
82045

6TANV57CLI-35A

2-669

Total Access/NetVanta Carrier CLI Dictionary

show policer WORD performance-statistics 15-minute <1-96>


Usetheshowpolicerperformancestatistics15minutecommandtoviewaspecific15minute
intervalorarangeofintervals.

Syntax Description
WORD

Displayspecifiedpolicer

Usage Examples
ThefollowingisasampleoutputoftheshowpolicerWORDperformancestatistics15minute
<196>command.
#show policer POL1 performance-statistics 15-minute 4
Policer POL1
15-Minute PM (4)
23:30
Ingress Green Frames

Ingress Green Bytes

Ingress Yellow Frames

Ingress Yellow Bytes

Ingress Red Frames

Ingress Red Bytes

Green Frame Discards

Green Octet Discards

Yellow Frame Discards

Yellow Octet Discards

Ingress Green Frames

Ingress Green Bytes

Ingress Yellow Frames

Ingress Yellow Bytes

Ingress Red Frames

Ingress Red Bytes

Green Frame Discards

Green Octet Discards

Yellow Frame Discards

Yellow Octet Discards

Policer POL1
15-Minute PM (5)
23:15

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-670

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82047

6TANV57CLI-35A

2-671

Total Access/NetVanta Carrier CLI Dictionary

show policer WORD performance-statistics 24-hour <1-7>


Usetheshowpolicerperformancestatistics24hourcommandtoviewperformancestatistics
foraspecificintervalorarangeofintervals.

Syntax Description
WORD

Displayspecifiedpolicer

Usage Examples
ThefollowingisasampleoutputoftheshowpolicerWORDperformancestatistics24hour
<17>command.
#show policer POL1 performance-statistics 24-hour 2-3
Policer POL1
24-Hour PM (2)
10/31
Ingress Green Frames

n/a

Ingress Green Bytes

n/a

Ingress Yellow Frames

n/a

Ingress Yellow Bytes

n/a

Ingress Red Frames

n/a

Ingress Red Bytes

n/a

Green Frame Discards

n/a

Green Octet Discards

n/a

Yellow Frame Discards

n/a

Yellow Octet Discards

n/a

Ingress Green Frames

n/a

Ingress Green Bytes

n/a

Ingress Yellow Frames

n/a

Ingress Yellow Bytes

n/a

Ingress Red Frames

n/a

Ingress Red Bytes

n/a

Green Frame Discards

n/a

Green Octet Discards

n/a

Yellow Frame Discards

n/a

Yellow Octet Discards

n/a

Policer POL1
24-Hour PM (3)
10/30

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

2-672

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82049

6TANV57CLI-35A

2-673

Total Access/NetVanta Carrier CLI Dictionary

show port-auth interface atm <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94949

2-674

6TANV57CLI-35A

Section 2, Commands - Common Commands

show port-auth interface efm-port <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94126

6TANV57CLI-35A

2-675

Total Access/NetVanta Carrier CLI Dictionary

show port-auth statistics interface atm <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94951

2-676

6TANV57CLI-35A

Section 2, Commands - Common Commands

show port-auth statistics interface efm-port <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94130

6TANV57CLI-35A

2-677

Total Access/NetVanta Carrier CLI Dictionary

show ppp-group [<shelf/slot>|<shelf>]


Usetheshowpppgroup<shelf/slot>commandtodisplayasummaryofconfiguration
parametersandstatusforallpppgroupsonthespecifiedshelf/slot..

Usage Examples
Thefollowingisasampleoutputoftheshowpppgroup[<shelf/slot>|<shelf>]command.
#show ppp-group 1/3
87 PPP Groups

2-678

Slot/

MinAct

Group

Links

Alias

Link

3/1

3/2

GROUP 3/2

3/1:2

3/3

GROUP 3/3

3/1:3

3/4

GROUP 3/4

3/1:4

3/5

GROUP 3/5

3/1:5

3/6

GROUP 3/6

3/1:6

3/7

GROUP 3/7

3/1:7

3/8

GROUP 3/8

3/1:8

3/9

GROUP 3/9

3/1:9

3/10

GROUP 3/10

3/1:10

3/11

GROUP 3/11

3/1:11

3/12

GROUP 3/12

3/1:12

3/13

GROUP 3/13

3/1:13

3/14

GROUP 3/14

3/1:14

3/15

GROUP 3/15

3/1:15

3/16

GROUP 3/16

3/1:16

3/17

GROUP 3/17

3/1:17

3/18

GROUP 3/18

3/1:18

3/19

GROUP 3/19

3/1:19

3/20

GROUP 3/20

3/1:20

3/21

GROUP 3/21

3/1:21

3/22

GROUP 3/22

3/1:22

3/23

GROUP 3/23

3/1:23

3/24

GROUP 3/24

3/1:24

3/25

GROUP 3/25

3/1:25

3/26

GROUP 3/26

3/1:26

3/27

GROUP 3/27

3/1:27

3/28

GROUP 3/28

3/1:28

3/29

GROUP 3/29

3/2:1

3/30

GROUP 3/30

3/2:2

3/31

GROUP 3/31

3/2:3

3/32

GROUP 3/32

3/2:4

6TANV57CLI-35A

Section 2, Commands - Common Commands

6TANV57CLI-35A

3/33

GROUP 3/33

3/2:5

3/34

GROUP 3/34

3/2:6

3/35

GROUP 3/35

3/2:7

3/36

GROUP 3/36

3/2:8

3/37

GROUP 3/37

3/2:9

3/38

GROUP 3/38

3/2:10

3/39

GROUP 3/39

3/2:11

3/40

GROUP 3/40

3/2:12

3/41

GROUP 3/41

3/2:13

3/42

GROUP 3/42

3/2:14

3/43

GROUP 3/43

3/2:15

3/44

GROUP 3/44

3/2:16

3/45

GROUP 3/45

3/2:17

3/46

GROUP 3/46

3/2:18

3/47

GROUP 3/47

3/2:19

3/48

GROUP 3/48

3/2:20

3/49

GROUP 3/49

3/2:21

3/50

GROUP 3/50

3/2:22

3/51

GROUP 3/51

3/2:23

3/52

GROUP 3/52

3/2:24

3/53

GROUP 3/53

3/2:25

3/54

GROUP 3/54

3/2:26

3/55

GROUP 3/55

3/2:27

3/56

GROUP 3/56

3/2:28

3/57

GROUP 3/57

3/3:1

3/58

GROUP 3/58

3/3:2

3/59

GROUP 3/59

3/3:3

3/60

GROUP 3/60

3/3:4

3/61

GROUP 3/61

3/3:5

3/62

GROUP 3/62

3/3:6

3/63

GROUP 3/63

3/3:7

3/64

GROUP 3/64

3/3:8

3/65

GROUP 3/65

3/3:9

3/66

GROUP 3/66

3/3:10

3/67

GROUP 3/67

3/3:11

3/68

GROUP 3/68

3/3:12

3/69

GROUP 3/69

3/3:13

3/70

GROUP 3/70

3/3:14

3/71

GROUP 3/71

3/3:15

3/72

GROUP 3/72

3/3:16

3/73

GROUP 3/73

3/3:17

3/74

GROUP 3/74

3/3:18

3/75

GROUP 3/75

3/3:19

3/76

GROUP 3/76

3/3:20

3/77

GROUP 3/77

3/3:21

3/78

GROUP 3/78

3/3:22

3/79

GROUP 3/79

3/3:23

2-679

Total Access/NetVanta Carrier CLI Dictionary

3/80

3/81

GROUP 3/80

3/3:24

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89661

2-680

6TANV57CLI-35A

Section 2, Commands - Common Commands

show ppp-link [<shelf/slot>|<shelf>]


Usetheshowppplink<shelf/slot>commandtodisplayalistofavailableppplinksonthe
specifiedshelf/slot.

Usage Examples
Thefollowingisasampleoutputoftheshowppplink[<shelf/slot>|<shelf>]command.
#show ppp-link 1/3
Slot
3

Port
1:1

Installed
Y

Port Type
CHANDS3 DS1

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89665

6TANV57CLI-35A

2-681

Total Access/NetVanta Carrier CLI Dictionary

show probe responder twamp


UsetheshowproberespondertwampcommandtodisplaytheTwowayActiveMeasurement
Protocol(TWAMP)proberesponderstatistics.TWAMPReflectorstatusState:Disabled
Port:862TestPacketsReceived:0Sent:0SessionsActive:0of6Opened:
0Closed:0Rejected:0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46090

2-682

6TANV57CLI-35A

Section 2, Commands - Common Commands

show probe responder twamp verbose


ProvisioningRole:Server/ReflectorState:EnabledControlPort:862
TimeoutsControl:15secondsTest:30secondsStatusResponderTotal
TestPacketsReceived:83Sent:83SessionsActive:1of10Opened/
Closed/Rejected:7/6/0Server#1(ClientIP=10.200.2.240)State=ActiveRcvd
TestPkts=4,SentTestPkts=4TCPSource/DestPort=6904/862AuthenticationMode
=UnauthenticatedServerTimeout=15seconds,Remaining=SUSPENDEDforactivetest
Reflector#1(SenderIP=10.200.2.240)RcvdPkts=4,SentPkts=4UDPSource/Dest
Port=1/2055PaddingLength=100bytesTypePDescriptor=41Packet
Timeout=10secondsTestTimeout=30seconds,Remaining=29seconds

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
61964

6TANV57CLI-35A

2-683

Total Access/NetVanta Carrier CLI Dictionary

show processes summary


UsetheshowprocessessummarycommandtoreturnmemoryusageandCPUutilizationfor
allcardsinaTotalAccess5000shelf.

Usage Examples
Thefollowingisasampleoutputoftheshowprocessessummarycommand.
#show processes summary
Current CPU Utilization: 18.39%
Maximum CPU Utilization: 100.00%
Total BlkMgr Used 15910976
Total BlkMgr Free

325344

Total BlkMgr Max

16236320

Total Heap Size

92441584

Total Heap Used

18546688

Total Heap Free

73894896

Functional Notes
TheCurrentCPUUtilizationoutputshowsthecurrent(instantaneous)CPUutilization.The
instantaneousvariabilityofCPUactivityrendersthismeasurementusefulonlyincarefully
controlleddevelopmentsituations.
TheMaximumCPUUtilizationoutputshowsthepeakvalueofCPUutilizationsince
poweredon.Thisvaluetypicallyreaches100%duringpowerup,sothismeasurementisnot
usefulformonitoringsystemhealth.
ThecalculationofCPUutilizationnumbersreflectsallactiveprocesses.Thiscaninclude
multiplelowprioritytasksthatareinterruptedifahigherpriorityprocessisrequired.
Therefore,ahighCPUutilizationalonedoesnotindicatesystemtroubleandisnotacausefor
concern.
TheblockmanagerstatisticsreflecttheRAMactuallyallocatedtomanagedblocksbytheheap
manager.Memoryallocatedfromtheheapisdividedintoblocksofcertainfixedsizes.
TheTotalBlkMgrUsedoutputshowstheamountofRAMconsumedbyblocksthatare
currentlyused.
TheTotalBlkMgrFreeoutputshowsthenumberofblocksthatarenolongerinuseandare
availableforfutureallocations.
TheTotalBlkMgrMaxoutputshowsthemaximumvalueoftheTotalBlkMgrUsedoutput
sincepoweredup.Theheapmemoryallocatedtoblocksisneverreturnedtotheheap,sothis
outputcorrelateswiththeTotalHeapUsedoutputbutdoesnotincludetheblockmanager
overhead.
TheheapistheRAMusedfordynamicallocation.
TheTotalHeapSizeoutputisthetotalamountofmemoryavailablefordynamicallocation.
TheTotalHeapUsedoutputistheamountofRAMcurrentlybeingused.
TheTotalHeapFreeoutputistheamountofRAMcurrentlyunused.
Therearenohardthresholdsforfreememory.Oneuseful,generalguidelineistheTotal
BlkMgrMaxouputshouldbelessthan70%oftheTotalHeapSizeoutput.Asteadily

2-684

6TANV57CLI-35A

Section 2, Commands - Common Commands

decreasingTotalHeapFreeoutputorTotalBlkMgrUsedoutputcanbeindicativeofa
memoryleak.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),CHDS3PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM
(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),
GPONAM(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),Quad
GigELM(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSL
AMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24
PortAM(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder
(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV
824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
77647

6TANV57CLI-35A

2-685

Total Access/NetVanta Carrier CLI Dictionary

show processes summary <shelf/slot>


Usetheshowprocessessummary<shelf/slot>commandtoreturnmemoryusageandCPU
utilizationforacardinaspecifiedTotalAccess5000shelfandslot.

Usage Examples
Thefollowingisasampleoutputoftheshowprocessessummary<shelf/slot>command.
#show processes summary 1/1
Shelf/Slot:1/SMA
Current CPU Utilization: 18.39%
Maximum CPU Utilization: 100.00%
Total BlkMgr Used 15910976
Total BlkMgr Free

325344

Total BlkMgr Max

16236320

Total Heap Size

92441584

Total Heap Used

18546688

Total Heap Free

73894896

Functional Notes
TheCurrentCPUUtilizationoutputshowsthecurrent(instantaneous)CPUutilization.The
instantaneousvariabilityofCPUactivityrendersthismeasurementusefulonlyincarefully
controlleddevelopmentsituations.
TheMaximumCPUUtilizationoutputshowsthepeakvalueofCPUutilizationsince
poweredon.Thisvaluetypicallyreaches100%duringpowerup,sothismeasurementisnot
usefulformonitoringsystemhealth.
ThecalculationofCPUutilizationnumbersreflectsallactiveprocesses.Thiscaninclude
multiplelowprioritytasksthatareinterruptedifahigherpriorityprocessisrequired.
Therefore,ahighCPUutilizationalonedoesnotindicatesystemtroubleandisnotacausefor
concern.
TheblockmanagerstatisticsreflecttheRAMactuallyallocatedtomanagedblocksbytheheap
manager.Memoryallocatedfromtheheapisdividedintoblocksofcertainfixedsizes.
TheTotalBlkMgrUsedoutputshowstheamountofRAMconsumedbyblocksthatare
currentlyused.
TheTotalBlkMgrFreeoutputshowsthenumberofblocksthatarenolongerinuseandare
availableforfutureallocations.
TheTotalBlkMgrMaxoutputshowsthemaximumvalueoftheTotalBlkMgrUsedoutput
sincepoweredup.Theheapmemoryallocatedtoblocksisneverreturnedtotheheap,sothis
outputcorrelateswiththeTotalHeapUsedoutputbutdoesnotincludetheblockmanager
overhead.
TheheapistheRAMusedfordynamicallocation.
TheTotalHeapSizeoutputisthetotalamountofmemoryavailablefordynamicallocation.
TheTotalHeapUsedoutputistheamountofRAMcurrentlybeingused.
TheTotalHeapFreeoutputistheamountofRAMcurrentlyunused.

2-686

6TANV57CLI-35A

Section 2, Commands - Common Commands

Therearenohardthresholdsforfreememory.Oneuseful,generalguidelineistheTotal
BlkMgrMaxouputshouldbelessthan70%oftheTotalHeapSizeoutput.Asteadily
decreasingTotalHeapFreeoutputorTotalBlkMgrUsedoutputcanbeindicativeofa
memoryleak.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),CHDS3PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM
(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),
GPONAM(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),Quad
GigELM(1187551E1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSL
AMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24
PortAM(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder
(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
66324

6TANV57CLI-35A

2-687

Total Access/NetVanta Carrier CLI Dictionary

show protection-group [<shelf/group>|WORD]


Usetheshowprotectiongroupcommandtodisplaythestatusofallprotectiongroups
configuredontheshelforaspecificprotectiongroup.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46207

2-688

6TANV57CLI-35A

Section 2, Commands - Common Commands

show qos [cos-map|untagged]


Usetheshowqos[cosmap|untagged]commandtodisplayinformationregardingqualityof
service(QoS)and802.1pclassofservice(CoS)settings.

Syntax Description
cosmap

DisplaythemapoftheLayer2ClassofService(CoS)valueto
eachqueue

untagged

Displaythequeuethatuntaggedframesegressinto

Usage Examples
Thefollowingisasampleoutputoftheshowqos[cosmap|untagged]command.
#show qos cos-map
CoS Priority: 0 1 2 3 4 5 6 7
Priority Queue: 1 1 2 2 3 3 4 4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46219

6TANV57CLI-35A

2-689

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces [efm-group|ethernet|gigabitethernet|muxponder-highspeed|muxponder-midspeed|tengigabit-ethernet]


Usetheshowqueueinterfacestodisplaythequeueinginformationforthespecifiedinterface.
Specifyaninterfaceintheformat<interfacetype[slot/port|slot/port.subinterfaceid|
interfaceid|interfaceid.subinterfaceid|ap|ap/radio|ap/radio.vap]>.Forexample,fora
T1interface,uset10/1;foranEthernetsubinterface,useeth0/1.1;foraPPPinterface,useppp
1;foranATMsubinterface,useatm1.1;andforawirelessvirtualaccesspoint,usedot11ap1/
1.1.Typetheshowqueue?commandtodisplayalistofvalidinterfaces.Usage
ExampleNetVanta838#showqueueinterfacesefmgroup1EFMGroup1IfId22Queue0
QueueCoS0QueueQueueSet0QueueWeightNAQueueWeight%NAEFM
Group1IfId22Queue1QueueCoS1QueueQueueSet1QueueWeightNAQueue
Weight%NAEFMGroup1IfId22Queue2QueueCoS2QueueQueueSet2Queue
WeightNAQueueWeight%NAEFMGroup1IfId22Queue3QueueCoS3Queue
QueueSet3QueueWeightNAQueueWeight%NA

Syntax Description
interfaces

Displayallqueuesbyinterface

efmgroup

Displayallqueuesoninterface

ethernet

Displayallqueuesoninterface

gigabitethernet

Displayallqueuesoninterface

muxponderhighspeed

Displayallqueuesoninterface

muxpondermidspeed

Displayallqueuesoninterface

tengigabitethernet

Displayallqueuesoninterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

2-690

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
63231

6TANV57CLI-35A

2-691

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces efm-group <shelf/slot/group>


Usetheshowqueueinterfacesefmgroup*commandtodisplaythequeueinginformationfor
aspecificEFMGroupinterface.

Functional Notes
Displaythespecifiedqueueparametersonthisefmgroupport.
Thedisplaycanbeasfollows
NetVanta838#showqueueinterfacesefmgroup17
EFMGroup1IfId22Queue7
QueueCoS7
QueueQueueSet7
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
63242

2-692

6TANV57CLI-35A

Section 2, Commands - Common Commands

show queue interfaces efm-group <shelf/slot/group> <0-n>


Usetheshowqueueinterfacesefmgroup**commandtodisplaythequeueinginformation
forspecificEFMGroupinterfacesandqueuenumber.

Syntax Description
<shelf/slot/group>

DisplayallqueuesonthespecifiedEFMgroup

Functional Notes
Displaythespecifiedqueueparametersonthisefmgroupport.
Thedisplaycanbeasfollows
NetVanta838#showqueueinterfacesefmgroup17
EFMGroup1IfId22Queue7
QueueCoS7
QueueQueueSet7
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
64874

6TANV57CLI-35A

2-693

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces ethernet <shelf/slot/port>


Usetheshowqueueinterfacesethernetcommandtodisplaythequeueinginformationfora
particularethernetinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesethernet<shelf/slot/port>
command.
838_112#show queue interfaces ethernet 1/0/2
Ethernet 1/0/2 IfId 10 Queue 0
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 1


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 2


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 3


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 4


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 5

2-694

Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

6TANV57CLI-35A

Section 2, Commands - Common Commands

Ethernet 1/0/2 IfId 10 Queue 6


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Ethernet 1/0/2 IfId 10 Queue 7


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

838_112#

Functional Notes
Displaythespecifiedqueueparametersonthisethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
67264

6TANV57CLI-35A

2-695

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces ethernet <shelf/slot/port> <0-n>


Usetheshowqueueinterfacesethernetcommandtodisplaythequeueinginformationfora
ethernetinterfaceandaqueue.

Syntax Description
<shelf/slot/port>

Displayallqueuesoninterface

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesethernet<shelf/slot/port><0n>
command.
838_112#show queue interfaces ethernet 1/0/2 0
Ethernet 1/0/2 IfId 10 Queue 0
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

838_112#

Functional Notes
Displaythespecifiedqueueparametersonthisethernetport.
Thedisplaycanbeasfollows
NetVanta838#showinterfacesethernet1queue0
ETH1IfId9Queue0
QueueCoS0
QueueQueueSet0
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-696

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
79263

6TANV57CLI-35A

2-697

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces gigabit-ethernet <shelf/slot/port>


Usetheshowqueueinterfacesgigabitethernetcommandtodisplaythequeueinginformation
foraparticulargigabitethernetinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesgigabitethernet<shelf/slot/
port>command.
838_112#show queue interfaces gigabit-ethernet 1/0/1
Gigabit Ethernet 1/0/1 IfId 26 Queue 0
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 1


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 2


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 3


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 4


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 5

2-698

Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

6TANV57CLI-35A

Section 2, Commands - Common Commands

Gigabit Ethernet 1/0/1 IfId 26 Queue 6


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Gigabit Ethernet 1/0/1 IfId 26 Queue 7


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

838_112#

Functional Notes
Displaythespecifiedqueueparametersonthisgigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
67175

6TANV57CLI-35A

2-699

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces gigabit-ethernet <shelf/slot/port> <0-n>


Usetheshowqueueinterfacesgigabitethernetcommandtodisplaythequeueinginformation
foraparticulargigabitethernetinterfaceandaqueue.

Syntax Description
<shelf/slot/port>

Displayallqueuesoninterface

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesgigabitethernet<shelf/slot/
port><0n>command.
838_112#show queue interfaces gigabit-ethernet 1/0/1 2
Gigabit Ethernet 1/0/1 IfId 26 Queue 2
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

838_112#

Functional Notes
Displaythespecifiedqueueparametersonthisgigabitethernetport.
Thedisplaycanbeasfollows
NetVanta838#showinterfacesgigabitethernet1queue1
GIGETH1IfId26Queue1
QueueCoS1
QueueQueueSet1
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-700

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
79262

6TANV57CLI-35A

2-701

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces muxponder-highspeed <shelf/slot/


port>
Functional Notes
Displaythespecifiedqueueparametersonthismuxponderhighspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145601

2-702

6TANV57CLI-35A

Section 2, Commands - Common Commands

show queue interfaces muxponder-highspeed <shelf/slot/


port> <0-n>
Syntax Description
<shelf/slot/port>

Specifiedinterface

Functional Notes
Displaythespecifiedqueueparametersonthismuxponderhighspeedport.
Thedisplaycanbeasfollows
#showinterfacesmuxponderhighspeed1queue1
muxponderhighspeed1IfId26Queue1
QueueCoS1
QueueQueueSet1
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145602

6TANV57CLI-35A

2-703

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces muxponder-midspeed <shelf/slot/port>


Usetheshowqueueinterfacesmuxpondermidspeedcommandtodisplaythequeueing
informationforaparticularmuxpondermidspeedinterface.

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesmuxpondermidspeed<shelf/
slot/port>command.
#show queue interfaces muxponder-midspeed 1/0/1
Muxponder Midspeed 1/0/1 IfId 26 Queue 0
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxponder Midspeed 1/0/1 IfId 26 Queue 1


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxponder Midspeed 1/0/1 IfId 26 Queue 2


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxpondert Midspeed 1/0/1 IfId 26 Queue 3


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxponder Midspeed 1/0/1 IfId 26 Queue 4


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxponder Midspeed 1/0/1 IfId 26 Queue 5

2-704

Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

6TANV57CLI-35A

Section 2, Commands - Common Commands

Muxponder Midspeed 1/0/1 IfId 26 Queue 6


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Muxponder Midspeed 1/0/1 IfId 26 Queue 7


Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthismuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145598

6TANV57CLI-35A

2-705

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces muxponder-midspeed <shelf/slot/port>


<0-n>
Usetheshowqueueinterfacesmuxpondermidspeedcommandtodisplaythequeueing
informationforaparticularmuxpondermidspeedinterfaceandaqueue.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowqueueinterfacesmuxpondermidspeed<shelf/
slot/port><0n>command.
#show queue interfaces muxponder-midspeed 1/0/1 2
Muxponder Midspeed 1/0/1 IfId 26 Queue 2
Queue CoS

Queue Weight

25

Queue Weight %

101

Queue Method

Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthismuxpondermidspeedport.
Thedisplaycanbeasfollows
#showinterfacesmuxpondermidspeed1queue1
muxpondermidspeed1IfId26Queue1
QueueCoS1
QueueQueueSet1
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-706

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145599

6TANV57CLI-35A

2-707

Total Access/NetVanta Carrier CLI Dictionary

show queue interfaces ten-gigabit-ethernet <shelf/slot/port>


Functional Notes
Displaythespecifiedqueueparametersonthistengigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67177

2-708

6TANV57CLI-35A

Section 2, Commands - Common Commands

show queue interfaces ten-gigabit-ethernet <shelf/slot/port>


<0-n>
Syntax Description
<shelf/slot/port>

Displayallqueuesoninterface

Functional Notes
Displaythespecifiedqueueparametersonthistengigabitethernetport.
Thedisplaycanbeasfollows
NetVanta838#showinterfacesgigabitethernet1queue1
GIGETH1IfId26Queue1
QueueCoS1
QueueQueueSet1
QueueWeightNA
QueueWeight%NA

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
79261

6TANV57CLI-35A

2-709

Total Access/NetVanta Carrier CLI Dictionary

show redundancy <shelf/slot>


Theshowredundancy<shelf/slot>commanddisplaysthecurrentredundancystatusofthe
specifiedslot.Thiscommandcanbeusedtodetermineifafailoveriscurrentlyallowedor
not.

Usage Examples
Thefollowingisasampleoutputoftheshowredundancy<shelf/slot>command.
#show redundancy 1/A
Failover Permitted:

Yes

My Slot:

Peer Slot:

Current State:

Standby

Revertive:

Disabled

Revertive Timeout:

25 seconds

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46244

2-710

6TANV57CLI-35A

Section 2, Commands - Common Commands

show remote-devices <remote-index>


Functional Notes
showremotedevices@1/1
showremotedevices@1/1/1.gpon
showremotedevices1@1/1/1.gpon

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133153

6TANV57CLI-35A

2-711

Total Access/NetVanta Carrier CLI Dictionary

show ring-generator <shelf>


Usethiscommandtodisplaystatusinformationabouttheringgeneratorinthespecifedshelf.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83058

2-712

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config [arp|auto-upgrade|counterprofile|dynamic-counter|evc|evc-map|event-logexport|fan|mevc|muxponder-ethernet|policer|powershedding|protectiongroup|queue|redundancy|sca|security|shaper|slot|system|syst


em-alarm|system-management-evc|systemtiming|temperature-sensor|tl1|verbose]
Usetheshowrunningconfigcommandtodisplayallthenondefaultparameterscontainedin
thecurrentrunningconfigurationfile.Specificportionsoftherunningconfigurationcanbe
displayedbasedonthecommandentered.

Syntax Description

6TANV57CLI-35A

runningconfig

Showallcurrentnondefaultrunningconfiguration

arp

ShowallARPnondefaultrunningconfiguration

autoupgrade

Showallautomaticupgradenondefaultrunningconfiguration

counterprofile

Showallcounterprofilenondefaultrunningconfiguration

dynamiccounter

Showalldynamiccounternondefaultrunningconfiguration

evc

ShowallEVCnondefaultrunningconfiguration

evcmap

ShowallEVCmapnondefaultrunningconfiguration

eventlogexport

Showalleventlogexportnondefaultrunningconfiguration

fan

Showallfannondefaultrunningconfiguration

mevc

ShowallMEVCnondefaultrunningconfiguration

muxponderethernet

DisplayallMuxponderEthernetnondefaultrunningconfigu
ration

policer

Showallpolicernondefaultrunningconfiguration

powershedding

Showallpowersheddingnondefaultrunningconfiguration

protectiongroup

Showallprotectiongroupnondefaultrunningconfiguration

queue

Showallqueuenondefaultrunningconfiguration

redundancy

Showallredundancynondefaultrunningconfiguration

sca

ShowallSystemConfigurationArchivalnondefaultrunning
configuration

security

Showallsecuritynondefaultrunningconfiguration

shaper

Showallshapernondefaultrunningconfiguration

2-713

Total Access/NetVanta Carrier CLI Dictionary

slot

Showallslotcommandsetnondefaultrunningconfiguration

system

Showallsystemnondefaultrunningconfiguration

systemalarm

Showallsystemalarmnondefaultrunningconfiguration

systemmanagementevc

ShowallSystemManagmentEVCnondefaultrunningconfigu
ration

systemtiming

Showallsystemtimingnondefaultrunningconfiguration

temperaturesensor

Showalltemperaturesensornondefaultrunningconfiguration

tl1

ShowallTL1nondefaultrunningconfiguration

verbose

Showallcurrentrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfig[arp|autoupgrade|counter
profile|dynamiccounter|evc|evcmap|eventlogexport|fan|mevc|muxponder
ethernet|policer|powershedding|protectiongroup|queue|redun
dancy|sca|security|shaper|slot|system|systemalarm|systemmanagementevc|system
timing|temperaturesensor|tl1|verbose]command.
#show running-config
!Building configuration...
!
!
clock timezone GMT 0 0
!
!
aaa authentication login default local
!
!
!
!
security
!
username ADMIN
password md5 "0x319F4D26E3C536B5DD871BB2C52E3178"
privilege admin
!
!
end
#

Local Security Permissions


Admin,TechSupport

2-714

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),EFMBondingProtectAM(1187250G1),EFMDS3CCAM
(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),FIBERAM
(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM
(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),Quad
GPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2
GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),
TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS
1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GE
HPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF
(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRD
RF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERF
RFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE
2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),SCMwithBridging(1187011G1),SM10GE(1187025G2),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46267

6TANV57CLI-35A

2-715

Total Access/NetVanta Carrier CLI Dictionary

show running-config arp [<shelf/slot>|verbose]


Syntax Description
arp

ShowallARPnondefaultrunningconfiguration

<shelf/slot>

Specifiedslot

verbose

ShowallARPrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
93507

2-716

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config arp <shelf/slot> verbose


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
93509

6TANV57CLI-35A

2-717

Total Access/NetVanta Carrier CLI Dictionary

show running-config auto-upgrade verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
87210

2-718

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config counter-profile [<shelf/slot>|verbose]


Usetheshowrunningconfigcounterprofilecommandtodisplaythecurrentnondefault
runningconfigurationparametersforallcounterprofiles.

Syntax Description
counterprofile

Showallcounterprofilenondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

Showallcounterprofilerunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87150

6TANV57CLI-35A

2-719

Total Access/NetVanta Carrier CLI Dictionary

show running-config counter-profile <shelf/slot> verbose


Usetheshowrunningconfigcounterprofile*verbosecommandtodisplayallrunning
configurationparametersfortheselectedcounterprofile.

Syntax Description
<shelf/slot>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87152

2-720

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config dynamic-counter [<shelf/slot>|verbose]


Usetheshowrunningconfigdynamiccountercommandtodisplaythecurrentnondefault
runningconfigurationparametersforalldynamiccounters.

Syntax Description
dynamiccounter

Showalldynamiccounternondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

Showalldynamiccounterrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87145

6TANV57CLI-35A

2-721

Total Access/NetVanta Carrier CLI Dictionary

show running-config dynamic-counter <shelf/slot> verbose


Usetheshowrunningconfigdynamiccounter*verbosecommandtodisplayallrunning
configurationparametersfortheselecteddynamiccounter.

Syntax Description
<shelf/slot>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87147

2-722

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config ethernet cfm


Usetheshowrunningconfigethernetcfmcommandtodisplayallrunningconfiguration
parametersforEthernetCFM.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigethernetcfmcommand.
#show running-config ethernet cfm
ethernet cfm domain char-string "MD_1" level 1 index 1
association char-string "MA_1" index 1
mep-database auto-discovery
component 1 vlan 1000
mp-sender-id

none

association char-string "MA_1_1" index 2


component 1 vlan 1001
!
!
ethernet cfm domain char-string "MD_2" level 2 index 2
association char-string "MA_2" index 1
ccm interval 100-milliseconds
component 1 vlan 2000
mp-sender-id

chassis-id

!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
87176

6TANV57CLI-35A

2-723

Total Access/NetVanta Carrier CLI Dictionary

show running-config ethernet cfm verbose


Usetheshowrunningconfigethernetcfmverbosecommandtodisplayallrunningconfigu
rationparametersforEthernetCFM.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigethernetcfmverbosecommand.
#show running-config ethernet cfm verbose
no ethernet cfm
ethernet cfm traceroute cache hold-time 100
ethernet cfm traceroute cache size 100
!
!
ethernet cfm domain char-string "MD_1" level 1 index 1
mp-sender-id none
association char-string "MA_1" index 1
ccm interval 1-second
mep-validation
mep-database auto-discovery
component 1 vlan 1000
mp-sender-id

none

association char-string "MA_1_1" index 2


ccm interval 1-second
mep-validation
mep-database configured-only
component 1 vlan 1
mp-sender-id

defer

!
!
ethernet cfm domain char-string "MD_2" level 2 index 2
mp-sender-id none
association char-string "MA_2" index 1
ccm interval 100-milliseconds
mep-validation
mep-database configured-only
component 1 vlan 2000
mp-sender-id

chassis-id

!
!
#

Local Security Permissions


Admin,TechSupport

2-724

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
87178

6TANV57CLI-35A

2-725

Total Access/NetVanta Carrier CLI Dictionary

show running-config evc [WORD|verbose]


Usetheshowrunningconfigevc[WORD|verbose]commandtodisplaythecurrentrunning
configurationforallEVCs.

Syntax Description
evc

ShowallEVCnondefaultrunningconfiguration

WORD

EVCname

verbose

ShowallEVCrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigevc[WORD|verbose]command.
#show running-config evc
Building configuration...
!
evc "110"
s-tag 110
c-tag 4095
mac-switched aging-time 0
no shutdown
!
!
evc "112"
s-tag 112
c-tag 4095
mac-switched aging-time 0
no shutdown
!
!
evc "300"
s-tag 300
c-tag 4095
mac-switched aging-time 0
no shutdown
!
!
end
#

Local Security Permissions


Admin,TechSupport

2-726

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87138

6TANV57CLI-35A

2-727

Total Access/NetVanta Carrier CLI Dictionary

show running-config evc WORD verbose


Usetheshowrunningconfigevc<WORD>verbosecommandtodisplayallrunningconfigu
rationparametersfortheselectedEVC.

Syntax Description
WORD

EVCname

Usage Examples
ThefollowingisasampleoutputoftheshowrunningconfigevcWORDverbosecommand.
#show running-config evc G1 verbose
evc "G1"
s-tag 1000
connect men-port ethernet 1/0/2
no preserve-ce-vlan
no shutdown
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87140

2-728

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config evc-map [WORD|verbose]


Usetheshowrunningconfigevcmap[WORD|verbose]commandtodisplaythecurrent
runningconfigurationforallEVCmaps.

Syntax Description
evcmap

ShowallEVCmapnondefaultrunningconfiguration

WORD

EVCmapname

verbose

ShowallEVCmaprunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigevcmap[WORD|verbose]
command.
#show running-config evc-map
Building configuration...
!
evc-map "MAP110" 1/9
connect evc "110" root
connect uni efm-port 1/9/31
men-pri inherit
encapsulation ipoe
relay-agent pppoe intermediate-agent
relay-agent dhcp-layer2
no relay-agent dhcp-layer2 option-82
no relay-agent remote-id
no relay-agent loop-characteristics
relay-agent pppoa-session-timeout 0
no ip igmp mode
no ip igmp immediate-leave
ip igmp last-member-query interval 1000
ip igmp last-member-query count 2
ip igmp version 2
no ip igmp max-multicast-bandwidth
no ip igmp max-multicast-groups
no net-bios
description ""
snmp-access
no shutdown
!
!
end
#

6TANV57CLI-35A

2-729

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90041

2-730

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config evc-map WORD [<shelf/slot>|verbose]


Syntax Description
WORD

EVCmapname

<shelf/slot>

Specifiedslot

verbose

Allconfigurationincludingdefaults

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90042

6TANV57CLI-35A

2-731

Total Access/NetVanta Carrier CLI Dictionary

show running-config evc-map WORD <shelf/slot> verbose


UsetheshowrunningconfigevcmapWORD<shelf/slot>verbosecommandtodisplayall
runningconfigurationparametersforspecifiedEVCmap.

Syntax Description
WORD

EVCmapname

<shelf/slot>

Specifiedslot

Usage Examples
ThefollowingisasampleoutputoftheshowrunningconfigevcmapWORD<shelf/slot>
verbosecommand.
#show running-config evc-map map110 1/9 verbose
Building configuration...
!
evc-map "MAP110" 1/9
connect evc "110" root
connect uni efm-port 1/9/31
men-pri inherit
encapsulation ipoe
relay-agent pppoe intermediate-agent
relay-agent dhcp-layer2
no relay-agent dhcp-layer2 option-82
no relay-agent remote-id
no relay-agent loop-characteristics
relay-agent pppoa-session-timeout 0
no ip igmp mode
no ip igmp immediate-leave
ip igmp last-member-query interval 1000
ip igmp last-member-query count 2
ip igmp version 2
no ip igmp max-multicast-bandwidth
no ip igmp max-multicast-groups
no net-bios
description ""
snmp-access
no shutdown
!
!
end
#

2-732

6TANV57CLI-35A

Section 2, Commands - Common Commands

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1)

Command ID
90045

6TANV57CLI-35A

2-733

Total Access/NetVanta Carrier CLI Dictionary

show running-config event-log-export verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
87202

2-734

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config fan [<shelf/slot>|verbose]


Usetheshowrunningconfigfancommandtodisplaythecurrentrunningconfigurationfor
allfans.

Syntax Description
fan

Showallfannondefaultrunningconfiguration

<shelf/slot>

Specifiedslot

verbose

Showallfanrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV824(1200634G4),NV828(1200634G2),NV844
(1200635G2)

Command ID
88818

6TANV57CLI-35A

2-735

Total Access/NetVanta Carrier CLI Dictionary

show running-config fan <shelf/slot> verbose


Usetheshowrunningconfigfan<shelf/slot>verbosecommandtodisplayallrunningconfig
urationsforthespecifiedfan.

Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV824(1200634G4),NV828(1200634G2),NV844
(1200635G2)

Command ID
88820

2-736

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface [adsl|atm|e1|efm-group|efmlink|efm-port|erps|ethernet|frame-relay|fxs|gigabitethernet|gpon|hdsl2|hdsl4|ip-host|lag-group|muxponderhighspeed|muxponder-midspeed|packet-timing|ppp-group|rfvideo|shdsl|t1|t3|ten-gigabit-ethernet|vdsl]


Usetheshowrunningconfiginterfacecommandtodisplaythecurrentrunningconfiguration
foraparticularinterface.Specifyaninterfaceintheformat<interfacetype[slot/port|slot/
port.subinterfaceid|interfaceid|interfaceid.subinterfaceid|ap|ap/radio|ap/radio.vap]>
Forexample,foraT1interface,uset10/1;foranEthernetsubinterface,useeth0/1.1;foraPPP
interface,useppp1;foranATMsubinterface,useatm1.1;andforawirelessvirtualaccess
point,usedot11ap1/1.1.Typeshowrunningconfiginterface?foracompletelistofvalidinter
faces.

Syntax Description

6TANV57CLI-35A

adsl

ShowallADSLnondefaultrunningconfiguration

atm

ShowallATMportnondefaultrunningconfiguration

e1

ShowallE1nondefaultrunningconfiguration

efmgroup

ShowallEFMGroupnondefaultrunningconfiguration

efmlink

ShowallEFMLinknondefaultrunningconfiguration

efmport

ShowallEFMportnondefaultrunningconfiguration

erps

ShowallERPSnondefaultrunningconfiguration

ethernet

ShowallEthernetnondefaultrunningconfiguration

framerelay

ShowallFrameRelayGroupnondefaultrunningconfiguration

fxs

ShowallFXSnondefaultrunningconfiguration

gigabitethernet

ShowallGigabitEthernetnondefaultrunningconfiguration

gpon

ShowallGPONnondefaultrunningconfiguration

hdsl2

ShowallHDSL2nondefaultrunningconfiguration

hdsl4

ShowallHDSL4nondefaultrunningconfiguration

iphost

ShowallIPHostnondefaultrunningconfiguration

laggroup

Showalllinkaggregationnondefaultrunningconfiguration

muxponderhighspeed

Shownondefaultrunningconfigurationatallmuxponder
highspeedports

muxpondermidspeed

Shownondefaultrunningconfigurationatallmuxponder
midspeedports

packettiming

Showallpackettimingnondefaultrunningconfiguration

2-737

Total Access/NetVanta Carrier CLI Dictionary

pppgroup

ShowallPPPgroupnondefaultrunningconfiguration

rfvideo

ShowallRFvideonondefaultrunningconfiguration

shdsl

ShowallSHDSLnondefaultrunningconfiguration

t1

ShowallT1nondefaultrunningconfiguration

t3

ShowallT3nondefaultrunningconfiguration

tengigabitethernet

ShowallTenGigabitEthernetnondefaultrunningconfiguration

vdsl

ShowallVDSLnondefaultrunningconfiguration

Functional Notes
Showinterfacerunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),EFME1AM(1188802G1),E1INTLPPPAM
(1188803G2),E1CEM32PortAM(1188801G1),EFMDS3CCAM(1187260G1),EFMDS3CH
AM(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSL
INTLAM(1188180E1),SM10GE(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM
(1187010L1),SCMG2(1187010G2),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),RPOTSAM(1187150L1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),FIBER
AM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),GPONAM(1187501G1),QuadGPONAM(1187502F1),
10GEthernetMuxponder(1174101F1),DS1PPPAM(1187803G2),CHDS3PPPAM
(1187220G1),VDSL2SplitterAM(1187125L1),NV814(1200637G4),NV818(1200637G2),NV
824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838

2-738

6TANV57CLI-35A

Section 2, Commands - Common Commands

OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
46269

6TANV57CLI-35A

2-739

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface adsl [[<shelf/slot>|<shelf/slot/


port>]|verbose]
Usetheshowrunningconfiginterfacevdsl[<shelf/slot>|verbose]commandtodisplaythe
currentrunningconfigurationforallVDSLinterfacesoraspecifiedVDSLinterface.

Syntax Description
adsl

ShowallADSLnondefaultrunningconfiguration

[<shelf/slot>|<shelf/slot/port>]Specifiedinterface
verbose

ShowallADSLrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
95563

2-740

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface adsl [<shelf/slot>|<shelf/slot/


port>] verbose
Usetheshowrunningconfiginterfacevdsl<shelf/slot>verbosecommandtodisplayall
currentrunningconfigurationsfortheselectedVDSLinterfaceandport.

Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
95565

6TANV57CLI-35A

2-741

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface atm [<shelf/slot>|verbose]


Syntax Description
atm

ShowallATMportnondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallATMportrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallATMPortinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
78096

2-742

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface atm <shelf/slot> verbose


Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedATMGroupinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
78098

6TANV57CLI-35A

2-743

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface atm-group <shelf/slot/group>


legacy-atm
Syntax Description
<shelf/slot/group>

Specifiedgroup

Functional Notes
ShowallrunningconfigurationfortheselectedATMgroupinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150669

2-744

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface atm-group <shelf/slot/group>


legacy-atm verbose
Syntax Description
<shelf/slot/group>

Specifiedgroup

Functional Notes
ShowallrunningconfigurationfortheselectedATMgroupinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150670

6TANV57CLI-35A

2-745

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface atm-group legacy-atm


Functional Notes
ShownondefaultrunningconfigurationsforallATMgroupinterfaces.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150662

2-746

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface atm-group legacy-atm verbose


Functional Notes
ShownondefaultrunningconfigurationsforallATMgroupinterfaces.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150665

6TANV57CLI-35A

2-747

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface e1 [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacet1commandtodisplaythecurrentrunningconfigu
rationfortheT1interface.

Syntax Description
e1

ShowallE1nondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallE1runningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallE1interfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77226

2-748

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface e1 <shelf/slot> verbose


Usetheshowrunningconfiginterfacet1*verbosecommandtodisplayallcurrentrunning
configurationsfortheselectedT1interface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedT1interface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77228

6TANV57CLI-35A

2-749

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface efm-group [<shelf/


slot>|verbose]
Usetheshowrunningconfiginterfaceefmgroupcommandtodisplaythecurrentrunning
configurationfortheEFMGroupinterface.

Syntax Description
efmgroup

ShowallEFMGroupnondefaultrunningconfiguration

<shelf/slot>

Specifiedgroup

verbose

ShowallEFMGrouprunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallEFMGroupinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46345

2-750

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface efm-group <shelf/slot> verbose


Usetheshowrunningconfiginterfaceefmgroup*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedEFMGroupinterface.

Syntax Description
<shelf/slot>

Specifiedgroup

Functional Notes
ShowallrunningconfigurationfortheselectedEFMGroupinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46347

6TANV57CLI-35A

2-751

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface efm-link [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfaceefmlinkcommandtodisplaythecurrentrunning
configurationfortheEFMLinkinterface.

Syntax Description
efmlink

ShowallEFMLinknondefaultrunningconfiguration

<shelf/slot>

Specifiedslot

verbose

ShowallEFMLinkrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallEFMLinkinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46349

2-752

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface efm-link <shelf/slot> verbose


Usetheshowrunningconfiginterfaceefmlink*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedEFMLinkinterface.

Syntax Description
<shelf/slot>

Specifiedslot

Functional Notes
ShowallrunningconfigurationfortheselectedEFMLinkinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46351

6TANV57CLI-35A

2-753

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface efm-port [<shelf/slot>|verbose]


Syntax Description
efmport

ShowallEFMportnondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallEFMportrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallEFMPortinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
78092

2-754

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface efm-port <shelf/slot> verbose


Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedEFMGroupinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
78094

6TANV57CLI-35A

2-755

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface erps [<shelf/slot/ring>|verbose]


Syntax Description
erps

ShowallERPSnondefaultrunningconfiguration

<shelf/slot/ring>

Specifiedinterface

verbose

ShowallERPSrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallERPSinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
118872

2-756

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface erps <shelf/slot/ring> verbose


Syntax Description
<shelf/slot/ring>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedERPSinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
118874

6TANV57CLI-35A

2-757

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface ethernet [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfaceethernetcommandtodisplaythecurrentrunning
configurationfortheEthernetinterface.

Syntax Description
ethernet

ShowallEthernetnondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallEthernetrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallEthernetinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46288

2-758

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface ethernet <shelf/slot> verbose


Usetheshowrunningconfiginterfaceethernet*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedEthernetinterface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedEthernetinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
46290

6TANV57CLI-35A

2-759

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface frame-relay [<shelf/slot/


group>|dlci|verbose]
Syntax Description
framerelay

ShowallFrameRelayGroupnondefaultrunningconfiguration

<shelf/slot/group>

Specifiedinterface

dlci

ShowallFrameRelayGroupPVCnondefaultrunningconfigu
ration

verbose

ShowallFrameRelayGrouprunningconfiguration

Functional Notes
Shownondefaultrunningconfigurationforallframerelayinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133762

2-760

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface frame-relay <shelf/slot/group>


[dlci|verbose]
Syntax Description
<shelf/slot/group>

Specifiedinterface

dlci

ShowallPVCnondefaultrunningconfigurationunderselected
interface

verbose

Allconfigurationincludingdefaults

Functional Notes
Showallnondefaultrunningconfigurationfortheselectedframerelayinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133764

6TANV57CLI-35A

2-761

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface frame-relay <shelf/slot/group>


dlci <16-991>
Syntax Description
<shelf/slot/group>

Specifiedinterface

Functional Notes
Showallrunningconfigurationfortheselectedframerelayinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133767

2-762

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface frame-relay <shelf/slot/group>


dlci <16-991> verbose
Syntax Description
<shelf/slot/group>

Specifiedinterface

<16991>

DLCI

Functional Notes
Showallrunningconfigurationfortheselectedframerelayinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133768

6TANV57CLI-35A

2-763

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface frame-relay dlci verbose


Functional Notes
ShowallrunningconfigurationforallframerelayPVCs

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133770

2-764

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface fxs [[<shelf/slot/port>|<remoteindex>]|verbose]


Syntax Description
fxs

ShowallFXSnondefaultrunningconfiguration

[<shelf/slot/port>|<remoteindex>]Specifiedinterface
verbose

ShowallFXSrunningconfiguration

Functional Notes
ShowallSHDSLnondefaultrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95587

6TANV57CLI-35A

2-765

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface fxs [<shelf/slot/port>|<remoteindex>] verbose


Syntax Description
<shelf/slot/port>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowallrunningconfigurationfortheselectedFXSinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95589

2-766

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface gigabit-ethernet [[<shelf/


slot>|<shelf/slot/port>|<remote-index>]|verbose]
Usetheshowrunningconfiginterfacegigabitethernetcommandtodisplaythecurrent
runningconfigurationfortheGigabitEthernetinterface.

Syntax Description
gigabitethernet

ShowallGigabitEthernetnondefaultrunningconfiguration

[<shelf/slot>|<shelf/slot/port>|<remoteindex>]Specifiedinterface
verbose

ShowallGigabitEthernetrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallGigabitEthernetinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),TA300
2POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE
(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
46301

6TANV57CLI-35A

2-767

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface gigabit-ethernet [<shelf/


slot>|<shelf/slot/port>|<remote-index>] verbose
Usetheshowrunningconfiginterfacegigabitethernet*verbosecommandtodisplayall
currentrunningconfigurationsfortheselectedGigabitEthernetinterface.

Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowallrunningconfigurationfortheselectedGigabitEthernetinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),TA300
2POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE
(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

2-768

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
46303

6TANV57CLI-35A

2-769

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface gpon [<shelf/slot/port>|verbose]


Usetheshowrunningconfiginterfacegponcommandtodisplaythecurrentrunningconfig
urationfortheGPONinterface.

Syntax Description
gpon

ShowallGPONnondefaultrunningconfiguration

<shelf/slot/port>

Specifiedinterface

verbose

ShowallGPONrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallGPONinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136703

2-770

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface gpon <shelf/slot/port> verbose


Usetheshowrunningconfiginterfacegpon*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedGPONinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedGPONinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136705

6TANV57CLI-35A

2-771

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface hdsl2 [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacehdsl2commandtodisplaythecurrentrunningconfig
urationfortheHDSL2interface.

Syntax Description
hdsl2

ShowallHDSL2nondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallHDSL2runningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallHDSL2interfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
46373

2-772

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface hdsl2 <shelf/slot> verbose


Usetheshowrunningconfiginterfacehdsl2*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedHDSL2interface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedHDSL2interface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
46375

6TANV57CLI-35A

2-773

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface hdsl4 [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacehdsl4commandtodisplaythecurrentrunningconfig
urationfortheHDSL4interface.

Syntax Description
hdsl4

ShowallHDSL4nondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallHDSL4runningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallHDSL4interfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
46377

2-774

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface hdsl4 <shelf/slot> verbose


Usetheshowrunningconfiginterfacehdsl4*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedHDSL4interface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedHDSL4interface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
46379

6TANV57CLI-35A

2-775

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface ip-host WORD [<shelf/


slot>|<remote-index>]
Syntax Description
WORD

IPHostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
111627

2-776

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface ip-host WORD [<shelf/


slot>|<remote-index>] verbose
Syntax Description
WORD

IPHostName

<shelf/slot>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
111628

6TANV57CLI-35A

2-777

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface ip-host verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
111625

2-778

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface lag-group [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacelaggroupcommandtodisplaythecurrentrunning
configurationforthelinkaggregationinterface.

Syntax Description
laggroup

Showalllinkaggregationnondefaultrunningconfiguration

<shelf/slot>

Specifiedgroup

verbose

Showalllinkaggregationrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallLinkaggregationinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
67113

6TANV57CLI-35A

2-779

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface lag-group <shelf/slot> verbose


Usetheshowrunningconfiginterfacelaggroup*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedlinkaggregationinterface.

Syntax Description
<shelf/slot>

Specifiedgroup

Functional Notes
ShowallrunningconfigurationfortheselectedTenGigabitEthernetinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
67115

2-780

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface muxponder-highspeed [[<shelf/


slot>|<shelf/slot/port>]|verbose]
Syntax Description
muxponderhighspeed

Shownondefaultrunningconfigurationatallmuxponder
highspeedports

[<shelf/slot>|<shelf/slot/port>]Specifiedinterface
verbose

Showallrunningconfigurationatallmuxponderhighspeed
ports

Functional Notes
Shownondefaultrunningconfigurationforallmuxponderhighspeedports

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136860

6TANV57CLI-35A

2-781

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface muxponder-highspeed [<shelf/


slot>|<shelf/slot/port>] verbose
Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

Functional Notes
Showallrunningconfigurationforaspecifiedmuxponderhighspeedport

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136862

2-782

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface muxponder-midspeed [[<shelf/


slot>|<shelf/slot/port>]|verbose]
Syntax Description
muxpondermidspeed

Shownondefaultrunningconfigurationatallmuxponder
midspeedports

[<shelf/slot>|<shelf/slot/port>]Specifiedinterface
verbose

Showallrunningconfigurationatallmuxpondermidspeed
ports

Functional Notes
Shownondefaultrunningconfigurationforallmuxpondermidspeedports

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136854

6TANV57CLI-35A

2-783

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface muxponder-midspeed [<shelf/


slot>|<shelf/slot/port>] verbose
Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

Functional Notes
Showallrunningconfigurationforaspecifiedmuxpondermidspeedport

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136856

2-784

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface packet-timing [<shelf/


slot>|verbose]
Syntax Description
packettiming

Showallpackettimingnondefaultrunningconfiguration

<shelf/slot>

Specifiedslot

verbose

Showallpackettimingrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144189

6TANV57CLI-35A

2-785

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface packet-timing <shelf/slot>


verbose
Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144192

2-786

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface ppp-group [<shelf/slot/


group>|verbose]
Usetheshowrunningconfiginterfacepppgroupcommandtodisplaythecurrentrunning
configurationforallPPPgroup.

Syntax Description
pppgroup

ShowallPPPgroupnondefaultrunningconfiguration

<shelf/slot/group>

Specifiedgroup

verbose

ShowallPPPgrouprunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfiginterfacepppgroup[<shelf/slot/
group>|verbose]command.
#show running-config interface ppp-group
interface ppp-group 1/3/2
alias GROUP 3/2
link 3/1:2
peer default ip address 10.10.10.1
peer default ip default-gateway 10.10.10.1
no magic-number
no shutdown
!
!
interface ppp-group 1/3/3
alias GROUP 3/3
link 3/1:3
peer default ip address 10.10.10.1
peer default ip default-gateway 10.10.10.1
no magic-number
no shutdown
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-787

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89354

2-788

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface ppp-group <shelf/slot/group>


verbose
Usetheshowrunningconfiginterfacepppgroup<shelf/slot/group>verbosecommandto
displayallrunningconfigurationsforthespecifiedPPPgroup.

Syntax Description
<shelf/slot/group>

Specifiedgroup

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfiginterfacepppgroup<shelf/slot/
group>verbosecommand.
#show running-config interface ppp-group verbose
interface ppp-group 1/3/2
alias GROUP 3/2
link 3/1:2
peer default ip address 10.10.10.1
peer default ip default-gateway 10.10.10.1
no peer default ip dns
no magic-number
lqm
no pfc
no acfc
restart-timer 3
max-terminate 2
max-configure 10
max-failure 5
no shutdown
!
!
interface ppp-group 1/3/3
alias GROUP 3/3
link 3/1:3
peer default ip address 10.10.10.1
peer default ip default-gateway 10.10.10.1
no peer default ip dns
no magic-number
lqm
no pfc
no acfc
restart-timer 3
max-terminate 2
max-configure 10
max-failure 5
no shutdown

6TANV57CLI-35A

2-789

Total Access/NetVanta Carrier CLI Dictionary

!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89356

2-790

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface pseudowire [<shelf/slot>|<shelf/


slot/pwe>|<remote-index>] cem
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131199

6TANV57CLI-35A

2-791

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface pseudowire [<shelf/slot>|<shelf/


slot/pwe>|<remote-index>] cem verbose
Syntax Description
<shelf/slot>

Specifiedslot

<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131200

2-792

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface pseudowire cem


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
134035

6TANV57CLI-35A

2-793

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface pseudowire cem verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
134036

2-794

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface rf-video [<remoteindex>|verbose]


Syntax Description
rfvideo

ShowallRFvideonondefaultrunningconfiguration

<remoteindex>
verbose

ShowallRFvideorunningconfigurationincludingdefaults

Functional Notes
ShowrunningconfigurationfortheselectedRFVideointerface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R
2POTS2GERFoG(1187715G1),TA3612POTS1GERF(1287711G1),TA3622POTS
2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GE
HPNARF(1287712G3)

Command ID
144625

6TANV57CLI-35A

2-795

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface rf-video <remote-index>


verbose
Syntax Description
dynamic
<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Functional Notes
ShowrunningconfigurationfortheselectedRFVideointerface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R
2POTS2GERFoG(1187715G1),TA3612POTS1GERF(1287711G1),TA3622POTS
2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GE
HPNARF(1287712G3)

Command ID
144957

2-796

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface shdsl [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfaceshdslcommandtodisplaythecurrentrunningconfig
urationfortheSHDSLinterface.

Syntax Description
shdsl

ShowallSHDSLnondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallSHDSLrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallSHDSLinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
46270

6TANV57CLI-35A

2-797

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface shdsl <shelf/slot> verbose


Usetheshowrunningconfiginterfaceshdsl*verbosecommandtodisplayallcurrent
runningconfigurationsfortheselectedSHDSLinterface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedSHDSLinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
46272

2-798

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface t1 [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacet1commandtodisplaythecurrentrunningconfigu
rationfortheT1interface.

Syntax Description
t1

ShowallT1nondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallT1runningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallT1interfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45716

6TANV57CLI-35A

2-799

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface t1 <shelf/slot> verbose


Usetheshowrunningconfiginterfacet1*verbosecommandtodisplayallcurrentrunning
configurationsfortheselectedT1interface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedT1interface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45718

2-800

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface t3 [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfacet3commandtodisplaythecurrentrunningconfigu
rationforthet3interface

Syntax Description
t3

ShowallT3nondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

ShowallT3runningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallT3interfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
46276

6TANV57CLI-35A

2-801

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface t3 <shelf/slot> verbose


Usetheshowrunningconfiginterfacet3*verbosecommandtodisplayallcurrentrunning
configurationsfortheselectedT3interface.

Syntax Description
<shelf/slot>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedT3interface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
46278

2-802

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface ten-gigabit-ethernet [[<shelf/


slot>|<shelf/slot/port>]|verbose]
Usetheshowrunningconfiginterfacetengigabitethernetcommandtodisplaythecurrent
runningconfigurationfortheTenGigabitEthernetinterface.

Syntax Description
tengigabitethernet

ShowallTenGigabitEthernetnondefaultrunningconfiguration

[<shelf/slot>|<shelf/slot/port>]Specifiedinterface
verbose

ShowallTenGigabitEthernetrunningconfiguration

Functional Notes
ShownondefaultrunningconfigurationforallTenGigabitEthernetinterfaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67108

6TANV57CLI-35A

2-803

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface ten-gigabit-ethernet [<shelf/


slot>|<shelf/slot/port>] verbose
Usetheshowrunningconfiginterfacetengigabitethernet*verbosecommandtodisplayall
currentrunningconfigurationsfortheselectedTenGigabitEthernetinterface.

Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

Functional Notes
ShowallrunningconfigurationfortheselectedTenGigabitEthernetinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67110

2-804

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config interface vdsl [[<shelf/slot>|<shelf/slot/


port>]|verbose]
Usetheshowrunningconfiginterfacevdsl[<shelf/slot>|verbose]commandtodisplaythe
currentrunningconfigurationforallVDSLinterfacesoraspecifiedVDSLinterface.

Syntax Description
vdsl

ShowallVDSLnondefaultrunningconfiguration

[<shelf/slot>|<shelf/slot/port>]Specifiedinterface
verbose

ShowallVDSLrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
77534

6TANV57CLI-35A

2-805

Total Access/NetVanta Carrier CLI Dictionary

show running-config interface vdsl [<shelf/slot>|<shelf/slot/


port>] verbose
Usetheshowrunningconfiginterfacevdsl<shelf/slot>verbosecommandtodisplayall
currentrunningconfigurationsfortheselectedVDSLinterfaceandport.

Syntax Description
<shelf/slot>

Specifiedinterface

<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
77536

2-806

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config ip igmp evc [WORD|verbose]


Syntax Description
evc

ShowallIGMPEVCnondefaultrunningconfiguration

WORD

EVCname

verbose

ShowallIGMPEVCrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104829

6TANV57CLI-35A

2-807

Total Access/NetVanta Carrier CLI Dictionary

show running-config ip igmp evc WORD [<shelf/slot>|verbose]


Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

verbose

Allconfigurationincludingdefaults

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104832

2-808

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config ip igmp evc WORD <shelf/slot> verbose


Syntax Description
WORD

EVCname

<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104835

6TANV57CLI-35A

2-809

Total Access/NetVanta Carrier CLI Dictionary

show running-config mevc [WORD|verbose]


Syntax Description
mevc

ShowallMEVCnondefaultrunningconfiguration

WORD

Name

verbose

ShowallMEVCrunningconfiguration

Functional Notes
Usetheshowrunningconfig?mevc[WORD

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136017

2-810

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config mevc WORD [<shelf/slot> |verbose]


Syntax Description
WORD

Name

<shelf/slot>

Specifiedinterface

verbose

Allconfigurationincludingdefaults

Functional Notes
Usetheshowrunningconfig?mevcWORDcommandtodisplaythecurrentrunningconfigu
rationfortheselectedMEVCs.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136018

6TANV57CLI-35A

2-811

Total Access/NetVanta Carrier CLI Dictionary

show running-config mevc WORD <shelf/slot> verbose


Syntax Description
WORD

Name

<shelf/slot>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
136022

2-812

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config muxponder-ethernet [<shelf/


slot>|verbose]
Syntax Description
muxponderethernet

DisplayallMuxponderEthernetnondefaultrunningconfigu
ration

<shelf/slot>

Specifiedslot

verbose

DisplayallMuxponderEthernetconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
147350

6TANV57CLI-35A

2-813

Total Access/NetVanta Carrier CLI Dictionary

show running-config muxponder-ethernet <shelf/slot> verbose


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
147354

2-814

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config policer [WORD|verbose]


Usetheshowrunningconfigpolicercommandtodisplaythecurrentnondefaultrunning
configurationparametersforallprovisionedpolicers.

Syntax Description
policer

Showallpolicernondefaultrunningconfiguration

WORD

Policername

verbose

Showallpolicerrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigpolicer[WORD|verbose]
command.
#show running-config policer
policer "P1"
cbs 1500
per uni ethernet 1/0/1
no shutdown
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
94030

6TANV57CLI-35A

2-815

Total Access/NetVanta Carrier CLI Dictionary

show running-config policer WORD [<shelf/slot>|verbose]


UsetheshowrunningconfigpolicerWORDcommandtodisplaythecurrentnondefault
runningconfigurationparametersfortheselectedpolicer.

Syntax Description
WORD

Policername

<shelf/slot>

Specifiedslot

verbose

Allconfigurationincludingdefaults

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
94032

2-816

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config policer WORD <shelf/slot> verbose


UsetheshowrunningconfigpolicerWORDverbosecommandtodisplayalltheconfigu
rationparametersfortheselectedpolicer.

Syntax Description
WORD

Policername

<shelf/slot>

Specifiedslot

Usage Examples
ThefollowingisasampleoutputoftheshowrunningconfigpolicerWORD<shelf/slot>
verbosecommand.
#show running-config policer P1 verbose
policer "P1"
cbs 1500
per uni ethernet 1/0/1
no shutdown
thresholds green-total 15-minute 0
thresholds green-discards 15-minute 0
thresholds yellow-total 15-minute 0
thresholds yellow-discards 15-minute 0
thresholds red-total 15-minute 0
thresholds green-total 24-hour 0
thresholds green-discards 24-hour 0
thresholds yellow-total 24-hour 0
thresholds yellow-discards 24-hour 0
thresholds red-total 24-hour 0
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1)

6TANV57CLI-35A

2-817

Total Access/NetVanta Carrier CLI Dictionary

Command ID
123882

2-818

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config power-shedding verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
87206

6TANV57CLI-35A

2-819

Total Access/NetVanta Carrier CLI Dictionary

show running-config probe responder twamp


Usetheshowrunningconfigproberespondertwampcommandtodisplaythecurrentnon
defaultrunningconfigurationparametersforTWAMPresponders.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigproberespondertwamp
command.
#show running-config probe responder twamp
probe responder twamp
control source-port 1001
max-sessions 5
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
94027

2-820

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config probe responder twamp verbose


Usetheshowrunningconfigproberespondertwampverbosecommandtodisplayallthe
configurationparametersforTWAMPresponders.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigproberespondertwampverbose
command.
#show running-config probe responder twamp
probe responder twamp
control source-port 1001
control timeout 900
test timeout 900
max-sessions 5
shutdown
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
94028

6TANV57CLI-35A

2-821

Total Access/NetVanta Carrier CLI Dictionary

show running-config protection-group [<shelf/slot>|verbose]


Usetheshowrunningconfiginterfaceprotectiongroupcommandtodisplaythecurrentnon
defaultrunningconfigurationparametersforallprotectioninterfaces.

Syntax Description
protectiongroup

Showallprotectiongroupnondefaultrunningconfiguration

<shelf/slot>

Specifiedslot

verbose

Showallprotectiongrouprunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1)

Command ID
87159

2-822

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config protection-group <shelf/slot> verbose


Usetheshowrunningconfiginterfaceprotectiongroup*verbosecommandtodisplayall
runningconfigurationparametersfortheselectedprotectioninterface.

Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1)

Command ID
87161

6TANV57CLI-35A

2-823

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface [efmgroup|ethernet|gigabit-ethernet|muxponderhighspeed|muxponder-midspeed|ten-gigabit-ethernet]


Usetheshowrunningconfigqueueinterfacecommandtodisplaythecurrentnondefault
runningconfigurationparametersforeitherallinterfacesoralltheinterfaceoftheentered
type.

Syntax Description
efmgroup

ShowallqueuenondefaultrunningconfigurationforEFM
Groups

ethernet

ShowallqueuenondefaultrunningconfigurationforEthernet
interfaces

gigabitethernet

ShowallqueuenondefaultrunningconfigurationforGigabit
Ethernetinterfaces

muxponderhighspeed

Showallqueuenondefaultrunningconfigurationfor
MuxponderHighspeedinterfaces

muxpondermidspeed

Showallqueuenondefaultrunningconfigurationfor
MuxponderMidspeedinterfaces

tengigabitethernet

ShowallqueuenondefaultrunningconfigurationforTen
GigabitEthernetinterfaces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterface[efm
group|ethernet|gigabitethernet|muxponderhighspeed|muxpondermidspeed|tengigabit
ethernet]command.
#show running-config queue interface ethernet
queue interface ethernet 1/0/1 0
!
!
queue interface ethernet 1/0/1 1
!
!
queue interface ethernet 1/0/1 2
drop-probability green 50
cos 4
!
!
queue interface ethernet 1/0/1 3
!
!
queue interface ethernet 1/0/1 4
!

2-824

6TANV57CLI-35A

Section 2, Commands - Common Commands

!
queue interface ethernet 1/0/1 5
!
!
queue interface ethernet 1/0/1 6
!
!
queue interface ethernet 1/0/1 7
!
!
queue interface ethernet 1/0/2 0
!
!
queue interface ethernet 1/0/2 1
!
!
queue interface ethernet 1/0/2 2
!
!
queue interface ethernet 1/0/2 3
!
!
queue interface ethernet 1/0/2 4
!
!
queue interface ethernet 1/0/2 5
!
!
queue interface ethernet 1/0/2 6
!
!
queue interface ethernet 1/0/2 7
!
!
queue interface ethernet 1/0/3 0
!
!
queue interface ethernet 1/0/3 1
!
!
queue interface ethernet 1/0/3 2
!
!
queue interface ethernet 1/0/3 3
!
!
queue interface ethernet 1/0/3 4

6TANV57CLI-35A

2-825

Total Access/NetVanta Carrier CLI Dictionary

!
!
queue interface ethernet 1/0/3 5
!
!
queue interface ethernet 1/0/3 6
!
!
queue interface ethernet 1/0/3 7
!
!
queue interface ethernet 1/0/4 0
!
!
queue interface ethernet 1/0/4 1
!
!
queue interface ethernet 1/0/4 2
!
!
queue interface ethernet 1/0/4 3
!
!
queue interface ethernet 1/0/4 4
!
!
queue interface ethernet 1/0/4 5
!
!
queue interface ethernet 1/0/4 6
!
!
queue interface ethernet 1/0/4 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

2-826

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
94011

6TANV57CLI-35A

2-827

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface efm-group [<shelf/slot/


group>|verbose]
Usetheshowrunningconfigqueueinterfaceefmgroup<shelf/slot/group>commandto
displaythecurrentnondefaultrunningconfigurationparametersfortheselected
interface.Usetheshowrunningconfigqueueinterfaceefmgroupverbosecommandto
displayalltheconfigurationparametersforallEFMgroupinterfaces.

Syntax Description
efmgroup

ShowallqueuenondefaultrunningconfigurationforEFM
Groups

<shelf/slot/group>

Specifiedgroup

verbose

ShowallqueuerunningconfigurationforEFMGroups

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfaceefmgroup
[<shelf/slot/group>|verbose]command.
#show running-config queue interface efm-group 1/0/1
queue interface efm-group 1/0/1 0
!
!
queue interface efm-group 1/0/1 1
!
!
queue interface efm-group 1/0/1 2
!
!
queue interface efm-group 1/0/1 3
!
!
queue interface efm-group 1/0/1 4
!
!
queue interface efm-group 1/0/1 5
max-depth 100
weight 10
cos 1
!
!
queue interface efm-group 1/0/1 6
!
!
queue interface efm-group 1/0/1 7
!

2-828

6TANV57CLI-35A

Section 2, Commands - Common Commands

!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
94020

6TANV57CLI-35A

2-829

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface efm-group <shelf/slot/


group> verbose
Usetheshowrunningconfigqueueinterfaceefmgroup<shelf/slot/group>verbosecommand
todisplayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/group>

Specifiedgroup

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfaceefmgroup
<shelf/slot/group>verbosecommand.
queue interface efm-group 1/0/1 0
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 0
!
!
queue interface efm-group 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface efm-group 1/0/1 2
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15

2-830

6TANV57CLI-35A

Section 2, Commands - Common Commands

thresholds wred yellow maximum 15


thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface efm-group 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface efm-group 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface efm-group 1/0/1 5
max-depth 100
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
weight 10
cos 1
!
!
queue interface efm-group 1/0/1 6
max-depth 255

6TANV57CLI-35A

2-831

Total Access/NetVanta Carrier CLI Dictionary

no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface efm-group 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
94022

2-832

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface ethernet [<shelf/slot/


port>|verbose]
Usetheshowrunningconfigqueueinterfaceethernet<shelf/slot/port>commandtodisplay
thecurrentnondefaultrunningconfigurationparametersfortheselectedinterface.Usethe
showrunningconfigqueueinterfaceethernetverbosecommandtodisplayalltheconfigu
rationparametersforallEthernetinterfaces.

Syntax Description
ethernet

ShowallqueuenondefaultrunningconfigurationforEthernet
interfaces

<shelf/slot/port>

Specifiedinterface

verbose

ShowallqueuerunningconfigurationforEthernetinterfaces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfaceethernet[<shelf/
slot/port>|verbose]command.
#show running-config queue interface ethernet 1/0/1
queue interface ethernet 1/0/1 0
!
!
queue interface ethernet 1/0/1 1
!
!
queue interface ethernet 1/0/1 2
drop-probability green 50
cos 4
!
!
queue interface ethernet 1/0/1 3
!
!
queue interface ethernet 1/0/1 4
!
!
queue interface ethernet 1/0/1 5
!
!
queue interface ethernet 1/0/1 6
!
!
queue interface ethernet 1/0/1 7
!
!

6TANV57CLI-35A

2-833

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
94012

2-834

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface ethernet <shelf/slot/port>


verbose
Usetheshowrunningconfigqueueinterfaceethernet<shelf/slot/port>verbosecommandto
displayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfaceethernet<shelf/
slot/port>verbosecommand.
#show running-config interface ethernet 1/0/1 verbose
queue interface ethernet 1/0/1 0
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 0
!
!
queue interface ethernet 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface ethernet 1/0/1 2
max-depth 255
no algorithm
drop-probability green 50
drop-probability yellow 10
thresholds wred green maximum 25

6TANV57CLI-35A

2-835

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred green minimum 15


thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface ethernet 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface ethernet 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface ethernet 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface ethernet 1/0/1 6

2-836

6TANV57CLI-35A

Section 2, Commands - Common Commands

max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface ethernet 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
94015

6TANV57CLI-35A

2-837

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface gigabit-ethernet [<shelf/


slot/port>|verbose]
Usetheshowrunningconfigqueueinterfacegigabitethernet<shelf/slot/port>commandto
displaythecurrentnondefaultrunningconfigurationparametersfortheselected
interface.Usetheshowrunningconfigqueueinterfacegigabitethernetverbosecommandto
displayalltheconfigurationparametersforallGigabitEthernetinterfaces.

Syntax Description
gigabitethernet

ShowallqueuenondefaultrunningconfigurationforGigabit
Ethernetinterfaces

<shelf/slot/port>

Specifiedinterface

verbose

ShowallqueuerunningconfigurationforGigabitEthernetinter
faces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacegigabitethernet
[<shelf/slot/port>|verbose]command.
#show running-config queue interface gigabit-ethernet
queue interface gigabit-ethernet 1/0/1 0
drop-probability green 70
drop-probability yellow 25
cos 7
!
!
queue interface gigabit-ethernet 1/0/1 1
!
!
queue interface gigabit-ethernet 1/0/1 2
!
!
queue interface gigabit-ethernet 1/0/1 3
!
!
queue interface gigabit-ethernet 1/0/1 4
!
!
queue interface gigabit-ethernet 1/0/1 5
!
!
queue interface gigabit-ethernet 1/0/1 6
!
!
queue interface gigabit-ethernet 1/0/1 7

2-838

6TANV57CLI-35A

Section 2, Commands - Common Commands

!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
94016

6TANV57CLI-35A

2-839

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface gigabit-ethernet <shelf/


slot/port> verbose
Usetheshowrunningconfigqueueinterfacegigabitethernet<shelf/slot/port>verbose
commandtodisplayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacegigabitethernet
<shelf/slot/port>verbosecommand.
#show running-config interface gigabit-ethernet 1/0/1 verbose
queue interface gigabit-ethernet 1/0/1 0
max-depth 255
no algorithm
drop-probability green 70
drop-probability yellow 25
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
queue interface gigabit-ethernet 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface gigabit-ethernet 1/0/1 2
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25

2-840

6TANV57CLI-35A

Section 2, Commands - Common Commands

thresholds wred green minimum 15


thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface gigabit-ethernet 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface gigabit-ethernet 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface gigabit-ethernet 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface gigabit-ethernet 1/0/1 6

6TANV57CLI-35A

2-841

Total Access/NetVanta Carrier CLI Dictionary

max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface gigabit-ethernet 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
94018

2-842

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface muxponder-highspeed


[<shelf/slot/port>|verbose]
Usetheshowrunningconfigqueueinterfacemuxponderhighspeed<shelf/slot/port>
commandtodisplaythecurrentnondefaultrunningconfigurationparametersforthe
selectedinterface.Usetheshowrunningconfigqueueinterfacemuxponderhighspeed
verbosecommandtodisplayalltheconfigurationparametersforallMuxponderHighspeed
interfaces.

Syntax Description
muxponderhighspeed

Showallqueuenondefaultrunningconfigurationfor
MuxponderHighspeedinterfaces

<shelf/slot/port>

Specifiedinterface

verbose

ShowallqueuerunningconfigurationforMuxponder
Highspeedinterfaces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacemuxponder
highspeed[<shelf/slot/port>|verbose]command.
#show running-config queue interface muxponder-highspeed
queue interface muxponder-highspeed 1/0/1 0
drop-probability green 70
drop-probability yellow 25
cos 7
!
!
queue interface muxponder-highspeed 1/0/1 1
!
!
queue interface muxponder-highspeed 1/0/1 2
!
!
queue interface muxponder-highspeed 1/0/1 3
!
!
queue interface muxponder-highspeed 1/0/1 4
!
!
queue interface muxponder-highspeed 1/0/1 5
!
!
queue interface muxponder-highspeed 1/0/1 6
!
!

6TANV57CLI-35A

2-843

Total Access/NetVanta Carrier CLI Dictionary

queue interface muxponder-highspeed 1/0/1 7


!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146181

2-844

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface muxponder-highspeed


<shelf/slot/port> verbose
Usetheshowrunningconfigqueueinterfacemuxponderhighspeed<shelf/slot/port>verbose
commandtodisplayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacemuxponder
highspeed<shelf/slot/port>verbosecommand.
#show running-config interface muxponder-highspeed 1/0/1 verbose
queue interface muxponder-highspeed 1/0/1 0
max-depth 255
no algorithm
drop-probability green 70
drop-probability yellow 25
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
queue interface muxponder-highspeed 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface muxponder-highspeed 1/0/1 2
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25

6TANV57CLI-35A

2-845

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred green minimum 15


thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface muxponder-highspeed 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface muxponder-highspeed 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface muxponder-highspeed 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface muxponder-highspeed 1/0/1 6

2-846

6TANV57CLI-35A

Section 2, Commands - Common Commands

max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface muxponder-highspeed 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146183

6TANV57CLI-35A

2-847

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface muxponder-midspeed


[<shelf/slot/port>|verbose]
Usetheshowrunningconfigqueueinterfacemuxpondermidspeed<shelf/slot/port>
commandtodisplaythecurrentnondefaultrunningconfigurationparametersforthe
selectedinterface.Usetheshowrunningconfigqueueinterfacemuxpondermidspeed
verbosecommandtodisplayalltheconfigurationparametersforallMuxponderMidspeed
interfaces.

Syntax Description
muxpondermidspeed

Showallqueuenondefaultrunningconfigurationfor
MuxponderMidspeedinterfaces

<shelf/slot/port>

Specifiedinterface

verbose

ShowallqueuerunningconfigurationforMuxponderMidspeed
interfaces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacemuxponder
midspeed[<shelf/slot/port>|verbose]command.
#show running-config queue interface muxponder-midspeed
queue interface muxponder-midspeed 1/0/1 0
drop-probability green 70
drop-probability yellow 25
cos 7
!
!
queue interface muxponder-midspeed 1/0/1 1
!
!
queue interface muxponder-midspeed 1/0/1 2
!
!
queue interface muxponder-midspeed 1/0/1 3
!
!
queue interface muxponder-midspeed 1/0/1 4
!
!
queue interface muxponder-midspeed 1/0/1 5
!
!
queue interface muxponder-midspeed 1/0/1 6
!
!

2-848

6TANV57CLI-35A

Section 2, Commands - Common Commands

queue interface muxponder-midspeed 1/0/1 7


!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146177

6TANV57CLI-35A

2-849

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue interface muxponder-midspeed


<shelf/slot/port> verbose
Usetheshowrunningconfigqueueinterfacemuxpondermidspeed<shelf/slot/port>verbose
commandtodisplayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacemuxponder
midspeed<shelf/slot/port>verbosecommand.
#show running-config interface muxponder-midspeed 1/0/1 verbose
queue interface muxponder-midspeed 1/0/1 0
max-depth 255
no algorithm
drop-probability green 70
drop-probability yellow 25
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
queue interface muxponder-midspeed 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface muxponder-midspeed 1/0/1 2
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25

2-850

6TANV57CLI-35A

Section 2, Commands - Common Commands

thresholds wred green minimum 15


thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface muxponder-midspeed 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface muxponder-midspeed 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface muxponder-midspeed 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface muxponder-midspeed 1/0/1 6

6TANV57CLI-35A

2-851

Total Access/NetVanta Carrier CLI Dictionary

max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface muxponder-midspeed 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146179

2-852

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface ten-gigabit-ethernet


[<shelf/slot/port>|verbose]
Usetheshowrunningconfigqueueinterfacegigabitethernet<shelf/slot/port>commandto
displaythecurrentnondefaultrunningconfigurationparametersfortheselected
interface.Usetheshowrunningconfigqueueinterfacegigabitethernetverbosecommandto
displayalltheconfigurationparametersforallGigabitEthernetinterfaces.

Syntax Description
tengigabitethernet

ShowallqueuenondefaultrunningconfigurationforTen
GigabitEthernetinterfaces

<shelf/slot/port>

Specifiedinterface

verbose

ShowallqueuerunningconfigurationfortenGigabitEthernet
interfaces

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacetengigabit
ethernet[<shelf/slot/port>|verbose]command.
#show running-config queue interface gigabit-ethernet
queue interface gigabit-ethernet 1/0/1 0
drop-probability green 70
drop-probability yellow 25
cos 7
!
!
queue interface gigabit-ethernet 1/0/1 1
!
!
queue interface gigabit-ethernet 1/0/1 2
!
!
queue interface gigabit-ethernet 1/0/1 3
!
!
queue interface gigabit-ethernet 1/0/1 4
!
!
queue interface gigabit-ethernet 1/0/1 5
!
!
queue interface gigabit-ethernet 1/0/1 6
!
!
queue interface gigabit-ethernet 1/0/1 7

6TANV57CLI-35A

2-853

Total Access/NetVanta Carrier CLI Dictionary

!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
100895

2-854

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config queue interface ten-gigabit-ethernet


<shelf/slot/port> verbose
Usetheshowrunningconfigqueueinterfacegigabitethernet<shelf/slot/port>verbose
commandtodisplayalltherunningconfigurationparametersfortheselectedinterface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueinterfacetengigabit
ethernet<shelf/slot/port>verbosecommand.
#show running-config interface gigabit-ethernet 1/0/1 verbose
queue interface gigabit-ethernet 1/0/1 0
max-depth 255
no algorithm
drop-probability green 70
drop-probability yellow 25
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
queue interface gigabit-ethernet 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface gigabit-ethernet 1/0/1 2
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25

6TANV57CLI-35A

2-855

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred green minimum 15


thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface gigabit-ethernet 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface gigabit-ethernet 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface gigabit-ethernet 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface gigabit-ethernet 1/0/1 6

2-856

6TANV57CLI-35A

Section 2, Commands - Common Commands

max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface gigabit-ethernet 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
100897

6TANV57CLI-35A

2-857

Total Access/NetVanta Carrier CLI Dictionary

show running-config queue verbose


Usetheshowrunningconfigqueueverbosecommandtodisplayalltherunningconfigu
rationparametersforallqueuesonthesystem.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigqueueverbosecommand.
#show running-config queue verbose
queue interface ethernet 1/0/1 0
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 0
!
!
queue interface ethernet 1/0/1 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface ethernet 1/0/1 2
max-depth 255
no algorithm
drop-probability green 50
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!

2-858

6TANV57CLI-35A

Section 2, Commands - Common Commands

!
queue interface ethernet 1/0/1 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface ethernet 1/0/1 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
queue interface ethernet 1/0/1 5
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 5
!
!
queue interface ethernet 1/0/1 6
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15

6TANV57CLI-35A

2-859

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred yellow maximum 15


thresholds wred yellow minimum 5
no weight
cos 6
!
!
queue interface ethernet 1/0/1 7
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 7
!
!
queue interface ethernet 1/0/2 0
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 0
!
!
queue interface ethernet 1/0/2 1
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 1
!
!
queue interface ethernet 1/0/2 2
max-depth 255

2-860

6TANV57CLI-35A

Section 2, Commands - Common Commands

no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 2
!
!
queue interface ethernet 1/0/2 3
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 3
!
!
queue interface ethernet 1/0/2 4
max-depth 255
no algorithm
drop-probability green 10
drop-probability yellow 10
thresholds wred green maximum 25
thresholds wred green minimum 15
thresholds wred yellow maximum 15
thresholds wred yellow minimum 5
no weight
cos 4
!
!
.....

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-861

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
94010

2-862

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config redundancy [<shelf/slot>|verbose]


Syntax Description
redundancy

Showallredundancynondefaultrunningconfiguration

<shelf/slot>

Specifiedinterface

verbose

Showallredundancyrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
87163

6TANV57CLI-35A

2-863

Total Access/NetVanta Carrier CLI Dictionary

show running-config redundancy <shelf/slot> verbose


Usetheshowrunningconfigredundancy<shelf/slot>verbosecommandtodisplayallredun
dancyrelatedconfigurationparametersfortheselectedredundantmodule.

Syntax Description
<shelf/slot>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
87165

2-864

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config remote-device ont [<remoteindex>|verbose]


Syntax Description
ont

ShowallOpticalNetworkTerminalnondefaultrunningconfigu
ration

<remoteindex>
verbose

ShowallRemoteDevicerunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133157

6TANV57CLI-35A

2-865

Total Access/NetVanta Carrier CLI Dictionary

show running-config remote-device ont <remote-index>


verbose
Syntax Description
dynamic
<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133160

2-866

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config sca verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
87214

6TANV57CLI-35A

2-867

Total Access/NetVanta Carrier CLI Dictionary

show running-config security verbose


Usetheshowrunningconfigsecurityverbosecommandtodisplayallrunningconfiguration
parametersforsecurity.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigsecurityverbosecommand.
#show running-config security verbose
alarm enable login success
alarm level login success info
alarm enable login failure
alarm level login failure info
!
username ADMIN
password md5 "0x319F4D26E3C536B5DD871BB2C52E3178"
privilege admin
no disable
!
username READONLY
password md5 "0x319F4D26E3C536B5DD871BB2C52E3178"
privilege read-only
no disable
!
username READWRITE
password md5 "0x319F4D26E3C536B5DD871BB2C52E3178"
privilege read-write
no disable
!
username TEST
password md5 "0x319F4D26E3C536B5DD871BB2C52E3178"
privilege test
no disable
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832

2-868

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87194

6TANV57CLI-35A

2-869

Total Access/NetVanta Carrier CLI Dictionary

show running-config shaper [WORD|verbose]


Usetheshowrunningconfigshapercommandtodisplaythecurrentnondefaultrunning
configurationparametersforallprovisionedshapers.

Syntax Description
shaper

Showallshapernondefaultrunningconfiguration

WORD

Shapername

verbose

Showallshaperrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigshaper[WORD|verbose]
command.
#show running-config policer
policer "P1"
cbs 1500
per uni ethernet 1/0/1
no shutdown
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838

2-870

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
123883

6TANV57CLI-35A

2-871

Total Access/NetVanta Carrier CLI Dictionary

show running-config shaper WORD [[<shelf/slot>|<remoteindex>]|verbose]


UsetheshowrunningconfigshaperWORDcommandtodisplaythecurrentnondefault
runningconfigurationparametersfortheselectedshaper.

Syntax Description
WORD

Shapername

[<shelf/slot>|<remoteindex>]Specifiedslot
verbose

Allconfigurationincludingdefaults

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
123884

2-872

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config shaper WORD [<shelf/slot>|<remoteindex>] verbose


UsetheshowrunningconfigshaperWORDverbosecommandtodisplayalltheconfigu
rationparametersfortheselectedshaper.

Syntax Description
WORD

Shapername

<shelf/slot>

Specifiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Usage Examples
ThefollowingisasampleoutputoftheshowrunningconfigshaperWORD[<shelf/
slot>|<remoteindex>]verbosecommand.
#show running-config policer P1 verbose
policer "P1"
cbs 1500
per uni ethernet 1/0/1
no shutdown
thresholds green-total 15-minute 0
thresholds green-discards 15-minute 0
thresholds yellow-total 15-minute 0
thresholds yellow-discards 15-minute 0
thresholds red-total 15-minute 0
thresholds green-total 24-hour 0
thresholds green-discards 24-hour 0
thresholds yellow-total 24-hour 0
thresholds yellow-discards 24-hour 0
thresholds red-total 24-hour 0
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-873

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
123887

2-874

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config slot verbose


Usetheshowrunningconfigslotverbosecommandtodisplayallofthemodulelevelparam
etersforeachslotcontainedinthecurrentrunningconfigurationfile.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
88207

6TANV57CLI-35A

2-875

Total Access/NetVanta Carrier CLI Dictionary

show running-config system verbose


Functional Notes
Thiscommandshowsallthesystemsrunningconfiguration.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
123865

2-876

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config system-alarm [<shelf>|verbose]


Usetheshowrunningconfigsystemalarmcommandtodisplaythecurrentnondefault
runningconfigurationparametersforallsystemalarms.

Syntax Description
systemalarm

Showallsystemalarmnondefaultrunningconfiguration

<shelf>

SpecifiedShelf

verbose

Showallsystemalarmrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigsystemalarm[<shelf>|verbose]
command.
#show running-config system-alarm
system-alarm
no alarm enable power-fail dc a
alarm level power-fail ac alert
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
87167

6TANV57CLI-35A

2-877

Total Access/NetVanta Carrier CLI Dictionary

show running-config system-alarm <shelf> verbose


Usetheshowrunningconfigsystemalarm<shelf>verbosecommandtodisplayallrunning
configurationforsystemalarmsonthespecifiedshelf.

Syntax Description
<shelf>

SpecifiedShelf

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
87169

2-878

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config system-management-evc verbose


Usetheshowrunningconfigsystemmanagementevcverbosecommandtodisplayall
runningconfigurationparametersforthesystemmanagementevc.

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigsystemmanagementevc
verbosecommand.
#show running-config system-management-evc verbose
system-management-evc
s-tag 1
ip address 0.0.0.0 255.255.255.0
men-pri 7
shutdown
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
87174

6TANV57CLI-35A

2-879

Total Access/NetVanta Carrier CLI Dictionary

show running-config system-timing [<shelf>|verbose]


Usetheshowrunningconfigsystemtimingcommandtodisplaythecurrentrunningconfig
urationforsystemtimingforallshelves.

Syntax Description
systemtiming

Showallsystemtimingnondefaultrunningconfiguration

<shelf>

SpecifiedShelf

verbose

Showallsystemtimingrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87155

2-880

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config system-timing <shelf> verbose


Usetheshowrunningconfigsystemtiming<shelf>verbosecommandtodisplayallrunning
configurationforsystemtimingonthespecifiedshelf.

Syntax Description
<shelf>

SpecifiedShelf

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87157

6TANV57CLI-35A

2-881

Total Access/NetVanta Carrier CLI Dictionary

show running-config temperature-sensor [<shelf/slot/


sensor>|verbose]
Usetheshowrunningconfigtemperaturesensorcommandtodisplaythecurrentrunning
configurationforalltemperaturesensors.

Syntax Description
temperaturesensor

Showalltemperaturesensornondefaultrunningconfiguration

<shelf/slot/sensor>

Specifiedsensor

verbose

Showalltemperaturesensorrunningconfiguration

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigtemperaturesensor[<shelf/slot/
sensor>|verbose]command.
#show running-config temperature-sensor
temperature-sensor 1/0/1
thresholds over-temperature fahrenheit 95
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90208

2-882

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config temperature-sensor <shelf/slot/sensor>


verbose
Usetheshowrunningconfigtemperaturesensor<shelf/slot/sensor>verbosecommandto
displayallrunningconfigurationsforthespecifiedtemperaturesensor.

Syntax Description
<shelf/slot/sensor>

Specifiedsensor

Usage Examples
Thefollowingisasampleoutputoftheshowrunningconfigtemperaturesensor<shelf/slot/
sensor>verbosecommand.
#show running-config temperature-sensor 1/0/1 verbose
temperature-sensor 1/0/1
thresholds over-temperature celsius 35
thresholds over-temperature fahrenheit 95
!
!

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90210

6TANV57CLI-35A

2-883

Total Access/NetVanta Carrier CLI Dictionary

show running-config tl1 verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
87198

2-884

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config voice [class-of-service|dial-plan|siptrunk|spre|user]


Syntax Description
classofservice

Showallclassofservicenondefaultrunningconfiguration

dialplan

Showalldialplannondefaultrunningconfiguration

siptrunk

Showalltrunknondefaultrunningconfiguration

spre

ShowallSPRE(specialprefix)nondefaultrunningconfiguration

user

Showallusernondefaultrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111629

6TANV57CLI-35A

2-885

Total Access/NetVanta Carrier CLI Dictionary

show running-config voice class-of-service [WORD|verbose]


Syntax Description
classofservice

Showallclassofservicenondefaultrunningconfiguration

WORD

Specifiedclassofservice

verbose

Showallclassofservicerunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111638

2-886

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config voice class-of-service WORD verbose


Syntax Description
WORD

Specifiedclassofservice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111641

6TANV57CLI-35A

2-887

Total Access/NetVanta Carrier CLI Dictionary

show running-config voice dial-plan verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111647

2-888

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config voice sip-trunk [<Txx>|verbose]


Syntax Description
siptrunk

Showalltrunknondefaultrunningconfiguration

<Txx>

Specifiedtrunk

verbose

Showalltrunkrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111634

6TANV57CLI-35A

2-889

Total Access/NetVanta Carrier CLI Dictionary

show running-config voice sip-trunk <Txx> verbose


Syntax Description
<Txx>

Specifiedtrunk

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111637

2-890

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config voice spre verbose


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111787

6TANV57CLI-35A

2-891

Total Access/NetVanta Carrier CLI Dictionary

show running-config voice user [NUMBER:20|verbose]


Syntax Description
user

Showallusernondefaultrunningconfiguration

NUMBER:20

Specifieduser

verbose

Showalluserrunningconfiguration

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111642

2-892

6TANV57CLI-35A

Section 2, Commands - Common Commands

show running-config voice user NUMBER:20 verbose


Syntax Description
NUMBER:20

Specifieduser

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111645

6TANV57CLI-35A

2-893

Total Access/NetVanta Carrier CLI Dictionary

show sca [autosave-status|restore-status|save-status]


Usetheshowsca[autosavestatus|restorestatus|savestatus]commandtoviewstatusinfor
mationforSCAfunctions.

Syntax Description
autosavestatus

Displayautosavestatus

restorestatus

Displaystatusofrestoration

savestatus

Displaymanualsavestatus

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82910

2-894

6TANV57CLI-35A

Section 2, Commands - Common Commands

show sca autosave-status realtime


UsetheshowscaautosavestatusrealtimecommandtoviewSCAautosavestatusinfor
mationwithcontinuousupdates.

Usage Examples
Thefollowingisasampleoutputoftheshowscaautosavestatusrealtimecommand.
#show sca autosave-status realtime
------------------------------------------------------------------------------Autosave Filename Prefix

Autosave Filename Suffix

: .sca

Current/Next Autosave Instance : 1


Autosave Only If Prov Changes

: ENABLE

Cards in Shelf

3 (1,B-SCM)

Cards With Prov Data

3 (1,B-SCM)

Cards With Changes

3 (1,B-SCM)

Date/Time of last SCA Autosave : N/A


Date/Time of next SCA Autosave : 12/20/08 00:00:00
Autosave Status

: Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommands.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82912

6TANV57CLI-35A

2-895

Total Access/NetVanta Carrier CLI Dictionary

show sca restore-status realtime


UsetheshowscarestorestatusrealtimecommandtoviewSCArestorestatusinformation
withcontinuousupdates.

Usage Examples
Thefollowingisasampleoutputoftheshowscarestorestatusrealtimecommand.
#show sca restore-status realtime
------------------------------------------------------------------------------SCA Remote Filename

: filename.sca

Cards in Shelf

3 (1,B-SCM)

Cards With Prov Data :

3 (1,B-SCM)

Cards In SCA

Cards w/ Prov In SCA :

Cards Restored

Cards Excluded

Cards NOT Restored

Cards w/ Exceptions

SCA Restore Status

: Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommands.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82916

2-896

6TANV57CLI-35A

Section 2, Commands - Common Commands

show sca save-status realtime


UsetheshowscasavestatusrealtimecommandtoviewstatusinformationforanSCAsave
functionwithcontinuousupdates.

Usage Examples
Thefollowingisasampleoutputoftheshowscasavestatusrealtimecommand.
#show sca save-status realtime
------------------------------------------------------------------------------SCA Remote Filename

: filename.sca

Cards in Shelf

3 (1,B-SCM)

Cards With Prov Data :

3 (1,B-SCM)

Cards With Changes

3 (1,B-SCM)

SCA Save Status

: Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommands.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82914

6TANV57CLI-35A

2-897

Total Access/NetVanta Carrier CLI Dictionary

show scr shelf-status


Usetheshowscrshelfstatus[<shelf>|realtime]commandtoviewSCRstatusinformation.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83073

2-898

6TANV57CLI-35A

Section 2, Commands - Common Commands

show scr shelf-status realtime


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83078

6TANV57CLI-35A

2-899

Total Access/NetVanta Carrier CLI Dictionary

show shaper WORD


UsetheshowshaperWORDcommandtodisplayconfigurationparametersandstatusforall
shapersoraspecifiedshaper.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89380

2-900

6TANV57CLI-35A

Section 2, Commands - Common Commands

show shaper WORD [<shelf/slot>|<remote-index>]


UsetheshowshaperWORD<shelf/slot>commandtodisplayconfigurationparametersand
currentstatusforthespecifiedshaper.

Syntax Description
WORD

Displayspecifiedshaper

Usage Examples
ThefollowingisasampleoutputoftheshowshaperWORD[<shelf/slot>|<remoteindex>]
command.
#show shaper shaper1 1/9
Name

State

Status

Interface

Queues

------------------------------------------------------------------------------SHAPER1

Enabled

Running

efm-port 01

0-7

Rate (kbps): 0
Last Error:
#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838

6TANV57CLI-35A

2-901

Total Access/NetVanta Carrier CLI Dictionary

(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
90194

2-902

6TANV57CLI-35A

Section 2, Commands - Common Commands

show sntp realtime


UsetheshowsntprealtimecommandtoviewSNTPstatusinformationwithcontinuous
updates.

Usage Examples
Thefollowingisasampleoutputoftheshowsntprealtimecommand.
#show sntp realtime
------------------------------------------------------------------------------Time Out Count

: 0

SNTP Status

: Idle

------------------------------------------------------------------------------Exit - 'Ctrl-C', Clear - 'c', Freeze - 'f', Resume - 'r'

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommands.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87227

6TANV57CLI-35A

2-903

Total Access/NetVanta Carrier CLI Dictionary

show system [inventory|parameters]


Syntax Description
system

Displayscurrentsysteminformation

inventory

Inventory

parameters

Displayscurrentsystemparameters

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2)

Command ID
77761

2-904

6TANV57CLI-35A

Section 2, Commands - Common Commands

show system-timing <shelf>


Theshowsystemtiming<shelf>commanddisplaysthestatusinformationfortheswitch
modulestimingsources.

Usage Examples
Thefollowingisasampleoutputoftheshowsystemtiming<shelf>command.
#show system-timing 1
Primary Source

Local

Secondary Source

Local

Fallback Source

None

Revert Mode

Revertive

Current Source

Primary

Primary Source Health

Up

Secondary Source Health

Up

Hop Count

Enabled, hops = 1

SSM Value

6 - Stratum 3

Priority Value

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46169

6TANV57CLI-35A

2-905

Total Access/NetVanta Carrier CLI Dictionary

show system-timing <shelf> detail


Theshowsystemtiming<shelf>detailcommanddisplaysthedetailedstatusinformationfor
theswitchmodulestimingsources.

Syntax Description
<shelf>

SpecifiedShelf

Usage Examples
Thefollowingisasampleoutputoftheshowsystemtiming<shelf>detailcommand.
#show system-timing 1 detail
Current Source

Primary

Primary Source Health

Up

Secondary Source Health

Up

Acquire Mode

On

Holdover Mode

Off

Timing From Peer

Off

Using Hop Count

On

Current SSM

0x06000101

Frequency Offset (ppb)

46

Phase Offset (ns)

Tx Packets

Tx Sequence Errors

Tx Phase Errors

gig-ethernet 1/B/1
Rx Packets

Sequence Errors

Invalid Errors

gig-ethernet 1/B/2
Rx Packets

Sequence Errors

Invalid Errors

Loop A
Rx Packets

Sequence Errors

Invalid Errors

Loop B
Rx Packets

2-906

6TANV57CLI-35A

Section 2, Commands - Common Commands

Sequence Errors

Invalid Errors

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
79266

6TANV57CLI-35A

2-907

Total Access/NetVanta Carrier CLI Dictionary

show table [evc|evc-map|mevc|nodeinformation|policer|shaper|system-timing]


Usetheshowtable[evc|evcmap|policer]commandtodisplayasummaryofallcurrently
provisionedEVCs,EVCmaps,orpolicers.

Syntax Description
evc

DisplayallcreatedEVCsintabularform

evcmap

DisplayallcreatedEVCmapsintabularform

mevc

DisplayallcreatedMEVCsintabularform

nodeinformation

Displaynodeinformationintabularform

policer

Displayallcreatedpolicersintabularform

shaper

Displayallcreatedshapersintabularform

systemtiming

Displaysystemtiminginformation

Usage Examples
Thefollowingisasampleoutputoftheshowtable[evc|evcmap|mevc|nodeinfor
mation|policer|shaper|systemtiming]command.
#show table evc
All EVC Tags Available in MEN
Tag

Name

State

Status

1000 evc1000

Enabled

Running

2000 evc2000

Enabled

Running

#show table evc-map


Name

State

Status

map1000

Enabled

Running

map2000

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-908

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),DS1PPPAM(1187803G2),E1INTLPPPAM
(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM
(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),
GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSL
AMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24
PortAM(1187560F1),QuadGPONAM(1187502F1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),10GEthernetMuxponder
(1174101F1),SM10GE(1187025G2),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS
2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2
POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1
PWE2GESBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
63657

6TANV57CLI-35A

2-909

Total Access/NetVanta Carrier CLI Dictionary

show table evc [mac-switched|tag-switched]


UsethiscommandtodisplayinformationaboutconfiguredEVCsintabularformat.

Syntax Description
evc

DisplayallcreatedEVCsintabularform

macswitched

DisplayonlyMACswitchedEVCsintabularform

tagswitched

DisplayonlytagswitchedEVCsintabularform

Usage Examples
Thefollowingisasampleoutputoftheshowtableevc[macswitched|tagswitched]
command.
#show table evc
All EVC Tags Available in MEN
Tag

Name

State

Status

101

DSCP

Enabled

Running

99

UNTAGGED-MGMT

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
64485

2-910

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table evc-map <shelf/slot>


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtableevcmap<shelf/slot>command.
#SHOW TABLE EVC-MAP
Name

State

Status

DSCP1

Enabled

Running

DSCP2

Enabled

Running

DSCP3

Enabled

Running

UNTAGGED-MGMT

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1)

Command ID
147599

6TANV57CLI-35A

2-911

Total Access/NetVanta Carrier CLI Dictionary

show table evc-map evc WORD


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Usage Examples
ThefollowingisasampleoutputoftheshowtableevcmapevcWORDcommand.
#SHOW TABLE EVC-MAP
Name

State

Status

DSCP1

Enabled

Running

DSCP2

Enabled

Running

DSCP3

Enabled

Running

UNTAGGED-MGMT

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3)

Command ID
109803

2-912

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table evc-map mevc WORD <shelf/slot>


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Syntax Description
WORD

Name

Usage Examples
ThefollowingisasampleoutputoftheshowtableevcmapmevcWORD<shelf/slot>
command.
#SHOW TABLE EVC-MAP
Name

State

Status

DSCP1

Enabled

Running

DSCP2

Enabled

Running

DSCP3

Enabled

Running

UNTAGGED-MGMT

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
139611

6TANV57CLI-35A

2-913

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces [adsl|efm-group|efm-link|framerelay|gpon|rf-video|shdsl|vdsl]


Usethiscommandtodisplayinformationaboutinterfacesintabularformat.

Syntax Description
adsl

DisplayADSLport

efmgroup

DisplayEFMgroup

efmlink

DisplayEFMlink

framerelay

DisplayFrameRelayGroup

gpon

ShowallGPONports

rfvideo

RFvideo

shdsl

DisplaySHDSLport

vdsl

DisplayVDSLport

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfaces[adsl|efmgroup|efm
link|framerelay|gpon|rfvideo|shdsl|vdsl]command.
TA5000#show table interfaces efm-group
Status
Shelf/Slot/Id
Down

Alias

Admin

Num EFM Links


Group

Rates

Cfg Active MinActive

Up

1/18/1

BRIDGE 1

UP

UP

45056

45056

1/18/2

BRIDGE 2

UP

UP

45056

45056

1/18/3

BRIDGE 3

UP

UP

45056

45056

1/18/4

BRIDGE 4

UP

UP

45056

45056

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1),EFMBondingProtectAM
(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM
(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM
(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),DS1FrameRelay
32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),GPONAM

2-914

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1187501G1),QuadGPONAM(1187502F1),TA3342POTS4GERF(1287735G1),TA3612
POTS1GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1
GE1FESWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3612
POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2POTS2
GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
63658

6TANV57CLI-35A

2-915

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces adsl [<shelf/slot/port>|<shelf/slot>]


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92109

2-916

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces adsl [<shelf/slot/port>|<shelf/slot>]


downstream performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

<shelf/slot>

DisplayallADSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92118

6TANV57CLI-35A

2-917

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces adsl [<shelf/slot/port>|<shelf/slot>]


downstream performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

<shelf/slot>

DisplayallADSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92120

2-918

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces adsl [<shelf/slot/port>|<shelf/slot>]


upstream performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

<shelf/slot>

DisplayallADSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92112

6TANV57CLI-35A

2-919

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces adsl [<shelf/slot/port>|<shelf/slot>]


upstream performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

<shelf/slot>

DisplayallADSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
92114

2-920

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces backplane <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecificbackplaneinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
64175

6TANV57CLI-35A

2-921

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces backplane <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificbackplane
interface.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
64179

2-922

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces efm-group <shelf/slot/group>


Usethiscommandtodisplayinformationsuchasalias,groupstatus,linkinformation,and
currentratesforaspecificEFMgroupintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfacesefmgroup<shelf/slot/group>
command.
TA5000#show table interfaces efm-group 1/18/1
Status
Shelf/Slot/Id
Down
1/18/1

Alias
BRIDGE 1

Admin
UP

Num EFM Links


Group

UP

Rates

Cfg Active MinActive


8

45056

Up
45056

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
63750

6TANV57CLI-35A

2-923

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces efm-group <shelf/slot/group>


performance-statistics [15-minute|24-hour]
UsethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificEFMgroup.
Thefollowingstatisticsareincluded:receivedframes,receivedbytes,receivedbadfragments,
receivedlostfragments,receivedloststarts,receivedlostends,transmittedframes,andtrans
mittedbytes.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/group>

DisplayspecifiedEFMgroup

15minute

Allintervals

24hour

Allintervals

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfacesefmgroup<shelf/slot/group>
performancestatistics[15minute|24hour]command.
TA5000#show table interfaces efm-group 1/18/1 performance-statistics 24hour
24 Hour Performance Shelf 1 Slot 18 ID 1
Name: BRIDGE 1
Start
Time
Curr
Start

Rx
Frames
241
0

Rx
Bytes
15582
0

Rx Bad

Rx Lost Rx Lost Rx Lost Tx

Frag

Frag

0
0

Start
0

End

0
0

Frames
8877

Tx
Bytes

1711822
0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1)

Command ID
45134

2-924

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>]
UsethiscommandtodisplayinformationsuchasassociatedEFMgroups,linkstatus,and
installstatusforaspecificEFMlinkintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfacesefmlink[<shelf/slot/
port>|<shelf/slot/port:chan>]command.
TA5000#show table interfaces efm-link 1/18/1
EFM Link
Shelf/Slot/Link
Status

EFM Group
Shelf/Slot/ID

1/18/1

1/18/1

Status

Near End

Admin Port
UP

UP

Installed
YES

Far End

Status
SYNC

SYNC

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64173

6TANV57CLI-35A

2-925

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64194

2-926

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces efm-link [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

SpecifiedEFMlink

<shelf/slot/port:chan>

SpecifiedEFMlink

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64200

6TANV57CLI-35A

2-927

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [[<shelf/slot/group>|<shelf/


slot>]|dlci|realtime]
Syntax Description
framerelay

DisplayFrameRelayGroup

[<shelf/slot/group>|<shelf/slot>]DisplayspecifiedFrameRelayGroup
dlci

DLCI

realtime

Periodicupdateddisplay

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133727

2-928

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133739

6TANV57CLI-35A

2-929

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991>
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133740

2-930

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> ip
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144228

6TANV57CLI-35A

2-931

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> ip realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144229

2-932

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 15-minute
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133743

6TANV57CLI-35A

2-933

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 15-minute
congestion
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144230

2-934

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 15-minute
congestion realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144231

6TANV57CLI-35A

2-935

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 15-minute realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133744

2-936

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 24-hour
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133745

6TANV57CLI-35A

2-937

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 24-hour
congestion
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144232

2-938

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 24-hour
congestion realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144233

6TANV57CLI-35A

2-939

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> performance-statistics 24-hour realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133746

2-940

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci <16-991> realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

<16991>

DLCI

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133741

6TANV57CLI-35A

2-941

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci ip
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144226

2-942

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci ip realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144227

6TANV57CLI-35A

2-943

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] dlci realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144224

2-944

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 15-minute
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133731

6TANV57CLI-35A

2-945

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 15-minute realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133732

2-946

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 15-minute signaling
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144220

6TANV57CLI-35A

2-947

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 15-minute signaling realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144221

2-948

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 24-hour
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133733

6TANV57CLI-35A

2-949

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 24-hour realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133734

2-950

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 24-hour signaling
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144222

6TANV57CLI-35A

2-951

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] performance-statistics 24-hour signaling realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144223

2-952

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay [<shelf/slot/group>|<shelf/


slot>] realtime
Syntax Description
<shelf/slot/group>

DisplayspecifiedFrameRelayGroup

<shelf/slot>

Selectedslot

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133729

6TANV57CLI-35A

2-953

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces frame-relay dlci [ip|realtime]


Syntax Description
dlci

DLCI

ip

InternetProtocol

realtime

Periodicupdateddisplay

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144216

2-954

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces frame-relay dlci ip realtime


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
144219

6TANV57CLI-35A

2-955

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces gigabit-ethernet <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecificgigabitethernetinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64172

2-956

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificgigabit
ethernetinterface.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
64183

6TANV57CLI-35A

2-957

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces gpon [<shelf/slot/port>|<remote-index>]


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecificgigabitethernetinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136651

2-958

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces gpon [<shelf/slot/port>|<remote-index>]


performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136654

6TANV57CLI-35A

2-959

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces gpon [<shelf/slot/port>|<remote-index>]


performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

DisplayspecifiedGPONport

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136655

2-960

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces muxponder-highspeed <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecificmuxponderhighspeedinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145657

6TANV57CLI-35A

2-961

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces muxponder-highspeed <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificmuxponder
highspeedinterface.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

Specifiedinterface

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145658

2-962

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces muxponder-midspeed <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecificmuxpondermidspeedinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145662

6TANV57CLI-35A

2-963

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces muxponder-midspeed <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificmuxponder
midspeedinterface.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

Specifiedinterface

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145663

2-964

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces rf-video <remote-index>


Functional Notes
ShowstatusfortheselectedRFVideointerfaceintableformat

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R
2POTS2GERFoG(1187715G1),TA3612POTS1GERF(1287711G1),TA3622POTS
2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GE
HPNARF(1287712G3)

Command ID
144629

6TANV57CLI-35A

2-965

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces shdsl <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,rate,errors,SNRmargin,andloop
attenuationforaspecificSHDSLportintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfacesshdsl<shelf/slot/port>
command.
TA5000#show table interfaces shdsl 1/18/1
SHDSL

Rate

Current

Sh/Sl/Id
Atten

State

Status (Kbps)

1/18/1

En-IS

Up

5632

ES

SES
0

UAS
0

LOSWS
0

CVC

SNR
20

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
63983

2-966

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces shdsl <shelf/slot/port> performancestatistics [15-minute|24-hour]


UsethiscommandtodisplaytheperformancemonitoringstatisticsforaspecificSHDSLport.
Thefollowingstatisticsareincluded:erroredseconds,severelyerroredseconds,unavailable
seconds,lossofsyncwordseconds,andcodeviolationcounts.Thestatisticsareshownin
either15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedSHDSLport

15minute

Allintervals

24hour

Allintervals

Usage Examples
Thefollowingisasampleoutputoftheshowtableinterfacesshdsl<shelf/slot/port>perfor
mancestatistics[15minute|24hour]command.
TA5000#show table interfaces shdsl 1/18/1 performance-statistics 24-hour
24 Hour SHDSL Performance Shelf 1 Slot 18 Port 1
Start time

ES

Current

Start

SES
0

UAS
37455

LOSWS
37455

26732

26732

CVC
0
0

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
63984

6TANV57CLI-35A

2-967

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces t1 [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
64193

2-968

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces t1 [<shelf/slot/port>|<shelf/slot/


port:chan>] performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
64199

6TANV57CLI-35A

2-969

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces t3 <shelf/slot/port> performancestatistics [15-minute|24-hour]


Usethiscommandtodisplay24hourintervalperformancestatisticsforthisinterfacein
tabularformat.

Syntax Description
<shelf/slot/port>

DisplayspecifiedT3port

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3)

Command ID
64157

2-970

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces ten-gigabit-ethernet <shelf/slot/port>


Usethiscommandtodisplayinformationsuchasstatus,linkinformation,andcurrentrates
foraspecifictengigabitethernetinterfaceintabularformat.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67157

6TANV57CLI-35A

2-971

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces ten-gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Usethiscommandtodisplaytheperformancemonitoringstatisticsforaspecifictengigabit
ethernetinterface.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67158

2-972

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>]


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
63974

6TANV57CLI-35A

2-973

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>]


downstream performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

DisplayspecifiedVDSLport

<shelf/slot>

DisplayallVDSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
82749

2-974

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>]


downstream performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

DisplayspecifiedVDSLport

<shelf/slot>

DisplayallVDSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
82751

6TANV57CLI-35A

2-975

Total Access/NetVanta Carrier CLI Dictionary

show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>]


upstream performance-statistics 15-minute
Syntax Description
<shelf/slot/port>

DisplayspecifiedVDSLport

<shelf/slot>

DisplayallVDSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
63977

2-976

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table interfaces vdsl [<shelf/slot/port>|<shelf/slot>]


upstream performance-statistics 24-hour
Syntax Description
<shelf/slot/port>

DisplayspecifiedVDSLport

<shelf/slot>

DisplayallVDSLports

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
63978

6TANV57CLI-35A

2-977

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp evc WORD <shelf/slot>


UsetheshowtableipigmpevcWORDtoshowIGMPinterfaceinformationforaspecified
EVCnameandslotintabularform.

Syntax Description
WORD

DisplayspecifiedEVC

Usage Examples
ThefollowingisasampleoutputoftheshowtableipigmpevcWORD<shelf/slot>command.
>show table ip igmp evc VIDEO
EVC VIDEO on 1/5
Current number of active groups

Total number of active hosts

Total number of joins sent to network

2616

Total number of joins received from users

Total number of successful joins from users

2601

Total number of unsuccessful joins from users

Total number of leave messages sent to network

13

Total number of leave messages received from users

11

Total number of general queries sent to users

51552

Total number of general queries received from network

1626

Total number of specific queries sent to users

Total number of specific queries received from network

Total number of invalid IGMP messages received

Functional Notes
ShowIGMPinformationforEVCnameintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

2-978

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
104894

6TANV57CLI-35A

2-979

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp evc WORD <shelf/slot> performancestatistics [15-minute|24-hour]


UsethiscommandtodisplaytheIGMPperformancemonitoringstatisticsforaspecificEVC
andslot.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
WORD

DisplayspecifiedEVC

<shelf/slot>

Specifiedslot

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
104895

2-980

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp evc WORD performance-statistics [15minute|24-hour]


UsethiscommandtodisplaytheIGMPperformancemonitoringstatisticsforaspecificEVC
forallslots.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
WORD

DisplayspecifiedEVC

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90266

6TANV57CLI-35A

2-981

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp evc-map WORD <shelf/slot>


UsetheshowtableipigmpevcmapWORD<shelf/slot>toshowIGMPinterfaceinformation
foraspecifiedEVCMapnameforaspecifiedshelf/slotintabularform.

Syntax Description
WORD

DisplayspecifiedEVCMap

Usage Examples
ThefollowingisasampleoutputoftheshowtableipigmpevcmapWORD<shelf/slot>
command.
>show ip table igmp evc-map VIDEO25 1/5
EVC-Map VIDEO25 on 1/5
Network interface evc-map VIDEO25 is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Router
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 127.0.0.2
IGMP helper address is enabled
Current activity

Groups:

Hosts:

Total joins

To Network: 0

From Users:

Total joins from user

Successful: 2639

Unsuccessful: 0

Total leave messages

To Network: 0

From Users:

Total general queries

To Users:

1630

From Network: 0

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

11

Functional Notes
ShowIGMPinformationforEVCMapnameintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

2-982

6TANV57CLI-35A

Section 2, Commands - Common Commands

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
90258

6TANV57CLI-35A

2-983

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp evc-map WORD <shelf/slot> performancestatistics [15-minute|24-hour]


UsethiscommandtodisplaytheIGMPperformancemonitoringstatisticsforaspecificEVC
Map.Thestatisticsareshownineither15minuteor24hourintervals.

Syntax Description
WORD

DisplayspecifiedEVCMap

<shelf/slot>

Selectslot

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
90259

2-984

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface adsl <shelf/slot/port>


Usetheshowipigmpinterfaceadsl<shelf/slot/port>toshowIGMPinterfaceinformationfor
aspecifiedADSLportintabularform.

Usage Examples
Thefollowingisasampleoutputoftheshowtableipigmpinterfaceadsl<shelf/slot/port>
command.
>show table ip igmp interface adsl 1/17/25
ADSL 1/17/25
Network interface evc-map VIDEO25 is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Router
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 127.0.0.2
IGMP helper address is enabled
Current activity

Groups:

Hosts:

Total joins

To Network: 0

From Users:

Total joins from user

Successful: 2147

Unsuccessful: 0

Total leave messages

To Network: 0

From Users:

Total general queries

To Users:

1388

From Network: 0

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

Functional Notes
ShowIGMPinterfaceinformationforADSLportintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-985

Total Access/NetVanta Carrier CLI Dictionary

Command ID
90253

2-986

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface adsl <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedADSLport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
90254

6TANV57CLI-35A

2-987

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp interface backplane <shelf/slot/port>


Usetheshowtableipigmpinterfacebackplane<shelf/slot/port>toshowIGMPinterface
informationforaspecifiedbackplaneportintabularform.

Usage Examples
Thefollowingisasampleoutputoftheshowtableipigmpinterfacebackplane<shelf/slot/
port>command.
>show table ip igmp interface backplane 1/5/1
Backplane 1/5/1
Network interface evc VIDEO is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Proxy
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 0.0.0.0
IGMP helper address is disabled
Current activity

Groups:

Hosts:

Total joins

To Network: 2118

From Users:

Total joins from user

Successful: 0

Unsuccessful: 0

Total leave messages

To Network: 10

From Users:

Total general queries

To Users:

From Network: 1379

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

Functional Notes
ShowIGMPinterfaceinformationforbackplaneintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM

2-988

6TANV57CLI-35A

Section 2, Commands - Common Commands

(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
90238

6TANV57CLI-35A

2-989

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp interface backplane <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedBackplaneinterface

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
90239

2-990

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface gigabit-ethernet <shelf/slot/port>


Usetheshowtableipigmpinterfacegigabitethernet<shelf/slot/port>toshowIGMPinterface
informationforaspecifiedGigabitEthernetportintabularform.

Usage Examples
Thefollowingisasampleoutputoftheshowtableipigmpinterfacegigabitethernet<shelf/
slot/port>command.
>show table ip igmp interface gigabit-ethernet 1/A/1
Gigabit-Ethernet 1/A/1
Network interface giga-eth 0/25 is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Proxy
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 0.0.0.0
IGMP helper address is disabled
Current activity

Groups:

Hosts:

Total joins

To Network: 2118

From Users:

Total joins from user

Successful: 0

Unsuccessful: 0

Total leave messages

To Network: 10

From Users:

Total general queries

To Users:

From Network: 1379

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

Functional Notes
ShowIGMPinterfaceinformationforGigabitEthernetintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

6TANV57CLI-35A

2-991

Total Access/NetVanta Carrier CLI Dictionary

Command ID
90243

2-992

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface gigabit-ethernet <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedGigabitEthernetport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),
SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
90244

6TANV57CLI-35A

2-993

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp interface ten-gigabit-ethernet <shelf/slot/


port>
Usetheshowtableipigmpinterfacetengigabitethernet<shelf/slot/port>toshowIGMP
interfaceinformationforaspecified10GigabitEthernetportintabularform.

Usage Examples
Thefollowingisasampleoutputoftheshowtableipigmpinterfacetengigabitethernet
<shelf/slot/port>command.
>show table ip igmp interface ten-gigabit-ethernet 1/A/1
10 Gigabit-Ethernet 1/A/1
Network interface giga-eth 0/25 is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Proxy
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 0.0.0.0
IGMP helper address is disabled
Current activity

Groups:

Hosts:

Total joins

To Network: 2118

From Users:

Total joins from user

Successful: 0

Unsuccessful: 0

Total leave messages

To Network: 10

From Users:

Total general queries

To Users:

From Network: 1379

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

Functional Notes
ShowIGMPinterfaceinformationfor10GigabitEthernetportintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

2-994

6TANV57CLI-35A

Section 2, Commands - Common Commands

Command ID
94293

6TANV57CLI-35A

2-995

Total Access/NetVanta Carrier CLI Dictionary

show table ip igmp interface ten-gigabit-ethernet <shelf/slot/


port> performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedTenGigabitEthernetport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94294

2-996

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface vdsl <shelf/slot/port>


Usetheshowtableipigmpinterfacevdsl<shelf/slot/port>toshowIGMPinterfaceinfor
mationforaspecifiedVDSLportintabularform.

Usage Examples
Thefollowingisasampleoutputoftheshowtableipigmpinterfacevdsl<shelf/slot/port>
command.
>show table ip igmp interface vdsl 1/5/25
VDSL 1/5/25
Network interface evc-map VIDEO25 is UP
Ip Address is 127.0.0.2, netmask is 255.255.255.255
IGMP is enabled on interface
Current IGMP version is 2
Current IGMP role is Router
IGMP query interval is 60 seconds
IGMP querier timeout is 120 seconds
IGMP max query response time is 10 seconds
Last member query count is 2
Last member query response interval is 1000 ms
IGMP querying router is 127.0.0.2
IGMP helper address is enabled
Current activity

Groups:

Hosts:

Total joins

To Network: 0

From Users:

Total joins from user

Successful: 2147

Unsuccessful: 0

Total leave messages

To Network: 0

From Users:

Total general queries

To Users:

1388

From Network: 0

Total specific queries

To Users:

From Network: 0

Total invalid IGMP messages

Received:

Functional Notes
ShowIGMPinterfaceinformationforVDSLportintabularform

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

6TANV57CLI-35A

2-997

Total Access/NetVanta Carrier CLI Dictionary

Command ID
90248

2-998

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table ip igmp interface vdsl <shelf/slot/port>


performance-statistics [15-minute|24-hour]
Syntax Description
<shelf/slot/port>

DisplayspecifiedVDSLport

15minute

Allintervals

24hour

Allintervals

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
90249

6TANV57CLI-35A

2-999

Total Access/NetVanta Carrier CLI Dictionary

show table mevc <shelf/slot> [mac-switched|tag-switched]


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Syntax Description
macswitched

DisplayonlyMACswitchedMEVCspershelf/slotintabular
form

tagswitched

DisplayonlytagswitchedMEVCspershelf/slotintabularform

Usage Examples
Thefollowingisasampleoutputoftheshowtablemevc<shelf/slot>[macswitched|tag
switched]command.
#SHOW TABLE EVC-MAP
Name

State

Status

DSCP1

Enabled

Running

DSCP2

Enabled

Running

DSCP3

Enabled

Running

UNTAGGED-MGMT

Enabled

Running

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
139615

2-1000

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table policer <shelf/slot>


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtablepolicer<shelf/slot>command.
#show table policer
Name

State

p1

Disabled Disabled

Status

p2

Disabled Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1)

Command ID
125246

6TANV57CLI-35A

2-1001

Total Access/NetVanta Carrier CLI Dictionary

show table queue interfaces [efm-group|ethernet|gigabitethernet|muxponder-highspeed|muxponder-midspeed|tengigabit-ethernet]


Usetheshowtablequeueinterfacescommandtodisplayallthequeuesparametersonthis
ethernetport.UsageExampleNetVanta838#showqueueinterfacesefmgroup1EFMGroup1
IfId22Queue0QueueCoS0QueueQueueSet0QueueWeightNAQueueWeight
%NAEFMGroup1IfId22Queue1QueueCoS1QueueQueueSet1QueueWeight
NAQueueWeight%NAEFMGroup1IfId22Queue2QueueCoS2QueueQueue
Set2QueueWeightNAQueueWeight%NAEFMGroup1IfId22Queue3QueueCoS
3QueueQueueSet3QueueWeightNAQueueWeight%NAEFMGroup1IfId22
Queue4QueueCoS4QueueQueueSet4QueueWeightNAQueueWeight%NA

Syntax Description
efmgroup

Displayallqueuesoninterface

ethernet

Displayallqueuesoninterface

gigabitethernet

Displayallqueuesoninterface

muxponderhighspeed

Displayallqueuesoninterface

muxpondermidspeed

Displayallqueuesoninterface

tengigabitethernet

Displayallqueuesoninterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
64876

2-1002

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table queue interfaces efm-group <shelf/slot/group>


Usetheshowtablequeueinterfacesefmgroupcommandtodisplayallthequeuesonthis
interfaceinatabularform.UsageExampleNetVanta838#showtablequeueinterfacesefm
group1/0/1EFMGroup1/0/1IfId22QueueCosWeightWeight%Method00
20850Explict1012530Explict2225101
Dynamic3325101Dynamic40256Dynamic5
0256Dynamic60256Dynamic7725
101Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthisefmgroupportinatabularform.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65631

6TANV57CLI-35A

2-1003

Total Access/NetVanta Carrier CLI Dictionary

show table queue interfaces ethernet <shelf/slot/port>


Usetheshowtablequeueinterfacesethernetcommandtodisplayallthequeuesonthis
interfaceinatabularform.UsageExampleNetVanta838#showtablequeueinterfacesethernet
1/0/1EFMGroup1/0/1IfId22QueueCosWeightWeight%Method00208
50Explict1012530Explict2225101
Dynamic3325101Dynamic40256Dynamic5
0256Dynamic60256Dynamic7725
101Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthisethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
67165

2-1004

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table queue interfaces gigabit-ethernet <shelf/slot/port>


Usetheshowtablequeueinterfacesgigabitethernetcommandtodisplayallthequeueson
thisinterfaceinatabularform.UsageExampleNetVanta838#showtablequeueinterfaces
gigabitethernet1/0/1EFMGroup1/0/1IfId22QueueCosWeightWeight%Method0
020850Explict1012530Explict2225
101Dynamic3325101Dynamic40256
Dynamic50256Dynamic60256Dynamic7
725101Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthisgigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
67167

6TANV57CLI-35A

2-1005

Total Access/NetVanta Carrier CLI Dictionary

show table queue interfaces muxponder-highspeed <shelf/


slot/port>
Functional Notes
Displaythespecifiedqueueparametersonthismuxponderhighspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145614

2-1006

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table queue interfaces muxponder-midspeed <shelf/slot/


port>
Usetheshowtablequeueinterfacesmuxpondermidspeedcommandtodisplayallthequeues
onthisinterfaceinatabularform.UsageExample#showtablequeueinterfacesmuxponder
midspeed1/0/1EFMGroup1/0/1IfId22QueueCosWeightWeight%Method0
020850Explicit1012530Explicit2225
101Dynamic3325101Dynamic40256
Dynamic50256Dynamic60256Dynamic7
725101Dynamic

Functional Notes
Displaythespecifiedqueueparametersonthismuxpondermidspeedinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145612

6TANV57CLI-35A

2-1007

Total Access/NetVanta Carrier CLI Dictionary

show table queue interfaces ten-gigabit-ethernet <shelf/slot/


port>
Functional Notes
Displaythespecifiedqueueparametersonthistengigabitethernetinterface.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67169

2-1008

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table remote-devices [<remote-index>|inactive]


Syntax Description
<remoteindex>
inactive

DisplayalltheinactivatedONTsserialnumberalongwiththeir
RegistrationIDs

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133154

6TANV57CLI-35A

2-1009

Total Access/NetVanta Carrier CLI Dictionary

show table remote-devices inactive <shelf/slot/port>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GE
RF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
144431

2-1010

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table shaper [<shelf/slot>|<remote-index>]


Usethiscommandtodisplayinformationaboutconfiguredpolicersintabularformat.

Usage Examples
Thefollowingisasampleoutputoftheshowtableshaper[<shelf/slot>|<remoteindex>]
command.
#show table policer
Name

State

p1

Disabled Disabled

Status

p2

Disabled Disabled

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
125279

6TANV57CLI-35A

2-1011

Total Access/NetVanta Carrier CLI Dictionary

show table sip registration


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95873

2-1012

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table sip registration <shelf/slot> [<Txx>|realtime]


Syntax Description
<shelf/slot>

Specifiedslot

<Txx>

Trunkidentifier

realtime

Displayoutputinrealtime

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95874

6TANV57CLI-35A

2-1013

Total Access/NetVanta Carrier CLI Dictionary

show table sip registration <shelf/slot> <Txx>


[WORD|realtime]
Syntax Description
<shelf/slot>

Specifiedslot

<Txx>

Trunkidentifier

WORD

Specificidentity

realtime

Displayoutputinrealtime

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
133797

2-1014

6TANV57CLI-35A

Section 2, Commands - Common Commands

show table sip registration <shelf/slot> <Txx> WORD realtime


Syntax Description
<shelf/slot>

Specifiedslot

<Txx>

Trunkidentifier

WORD

Specificidentity

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
133800

6TANV57CLI-35A

2-1015

Total Access/NetVanta Carrier CLI Dictionary

show table system-timing <shelf>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
124077

2-1016

6TANV57CLI-35A

Section 2, Commands - Common Commands

show temperature-sensor <shelf/slot/sensor>


Usetheshowtemperaturesensor<shelf/slot/sensor>commandtoshowthecurrentstatusof
thespecifiedtemperaturesensor.

Usage Examples
Thefollowingisasampleoutputoftheshowtemperaturesensor<shelf/slot/sensor>
command.
#show temperature-sensor 1/0/1
Internal Temperature
Current

: 30.40C / 86.72F

Maximum

: 30.40C / 86.72F

Threshold : 65.00C / 149.00F


#

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA500023inchFan(1187080L1),FIBERAM(1187552G1),ADSL2AM(1187101E1),ADSL2
INTLAM(1188101E1),ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM
(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2Splitter
AM(1187125L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM
(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),10GEthernet
Muxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
77248

6TANV57CLI-35A

2-1017

Total Access/NetVanta Carrier CLI Dictionary

show topology interfaces erps <shelf/slot/ring>


UsageExample:SM4GE#showinterfacering1/A/1topologybriefNumberofstations:3Ring
state:closed/consistentStationNameNodeidWestStatusEastStatusSMNet112
NR3RBSMNet123NR1NRSMNet231NR2NR
Notes:Ringstatecouldbeopenorclosed,andcouldbeinaconsistentorinconsistent
state.StatuscouldbeoneofNR,RB,MS,SF,FSinpriorityorder.

Functional Notes
Showsbrieftopologyforspecifiedringinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83144

2-1018

6TANV57CLI-35A

Section 2, Commands - Common Commands

show topology interfaces erps <shelf/slot/ring> detail


UsageExample:SM4GE#showinterfacering1/A/1topologydetailNumberofstations:3Ring
state:closed/consistentNodeid:1StationName:SMNet1MAC:
XX:XX:XX:XX:XX:XXWestnodeid:2WestMAC:XX:XX:XX:XX:XX:XXWestStatus:
NREastnodeid:3EastMAC:XX:XX:XX:XX:XX:XXEastStatus:RBNodeid:2:Notes:Ring
statecouldbeopenorclosed,andcouldbeinaconsistentorinconsistentstate.Statuscouldbe
oneofNR,RB,MS,SF,FSinpriorityorder.

Syntax Description
<shelf/slot/ring>

Selectring

Functional Notes
Showsdetailedtopologyforspecifiedringinterface

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83145

6TANV57CLI-35A

2-1019

Total Access/NetVanta Carrier CLI Dictionary

show topology tree


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
122708

2-1020

6TANV57CLI-35A

Section 2, Commands - Common Commands

show topology tree detail


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
122709

6TANV57CLI-35A

2-1021

Total Access/NetVanta Carrier CLI Dictionary

show topology tree detail <1-64>


Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
122710

2-1022

6TANV57CLI-35A

Section 2, Commands - Common Commands

show users [login-stats|realtime]


Usetheshowusers[loginstats|realtime]commandtodisplayinformationabouttheusers
currentlyloggedintothesystem.

Syntax Description
users

Displayalistofconnectionsanduserscurrentlyloggedin

loginstats

Showusersloginstatistics

realtime

Displayalistofconnectionsanduserscurrentlyloggedin

Usage Examples
Thefollowingisasampleoutputoftheshowusers[loginstats|realtime]command.
#show users login-stats
Username

Access

State

Logins

ADMIN

ADMIN

ENABLED

READONLY

READONLY

ENABLED

READWRITE

READWRITE

ENABLED

TEST

TEST

ENABLED

Functional Notes
Theclear(c)functiondoesnotoperatewiththiscommands.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77819

6TANV57CLI-35A

2-1023

Total Access/NetVanta Carrier CLI Dictionary

show users login-stats local


Usetheshowusersloginstatstoseetheconfiguredusersandhowmanytimestheyare
loggedintothesystem.

Usage Examples
Thefollowingisasampleoutputoftheshowusersloginstatslocalcommand.
#show users login-stats local
Username

Access

State

Logins

ADMIN

ADMIN

ENABLED

READONLY

READONLY

ENABLED

READWRITE

READWRITE

ENABLED

TEST

TEST

ENABLED

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89398

2-1024

6TANV57CLI-35A

Section 2, Commands - Common Commands

show version [<shelf/slot>|<remote-index>]


Usetheshowversion<shelf/slot>commandtodisplaythecurrentoperatingsystemversion
information.

Usage Examples
Thefollowingisasampleoutputoftheshowversion[<shelf/slot>|<remoteindex>]
command.
#show version 1/1
1/B

ADTRAN, Inc. TA5000 1187020E1 Copyright (c) 1999-2008

Product Revision

: G

Serial number

: LBADTN0826AE987

CLEI code

: BVL2NSMCTA

Flash Size

: 33554432 bytes

Dram Size

: 134217727 bytes

App Code Version

: D10.121

App Code Checksum

: 434543F7

Built on

: Thu Nov 06 05:14:14 2008

Boot Code Version

: C20.19boot

Boot Code Checksum

: C2A6

Built on

: Sun Mar 09 23:06:04 2008

System uptime is 3 days, 11 hours, 34 minutes, 36 seconds


System returned to ROM by External Hard Reset
#

Functional Notes
Theoutputofallshowcommandscanbelimitedbyappendingthefollowingmodifierstothe
endofthecommand:begin<text>,exclude<text>,andinclude<text>.Theincludemodifier
limitsoutputtolinesthatcontainthespecifiedtext.Theexcludemodifierexcludesanylines
withthespecifiedtext.Thebeginmodifierdisplaysthefirstlineofoutputwiththespecified
textandalllinesthereafter.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
TA500023inchFan(1187080L1),EFMBondingProtectAM(1187250G1),EFMDS3CCAM
(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM

6TANV57CLI-35A

2-1025

Total Access/NetVanta Carrier CLI Dictionary

(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),FIBERAM
(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM
(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),Quad
GPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2
GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),
TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS
1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GE
HPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF
(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRD
RF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERF
RFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE
2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
65637

2-1026

6TANV57CLI-35A

Section 2, Commands - Common Commands

show vlan <1-4094>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
88658

6TANV57CLI-35A

2-1027

Total Access/NetVanta Carrier CLI Dictionary

telnet A.B.C.D
UsethetelnetA.B.C.DcommandtospecifytheIPaddressoftheremotesystem.

Usage Examples
ThefollowingisanexampleofhowtousethetelnetA.B.C.Dcommand.
#telnet 10.44.7.74
Connecting....
#

Functional Notes
IPaddressesshouldbeexpressedindotteddecimalnotation(forexample,10.10.10.1).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42952

2-1028

6TANV57CLI-35A

Section 2, Commands - Common Commands

telnet A.B.C.D port <1-65535>


UsethetelnetA.B.C.Dport<165535>commandtospecifytheIPaddressandportofthe
remotesystem.

Syntax Description
A.B.C.D

IPaddressoftelnetserver

Usage Examples
ThefollowingisanexampleofhowtousethetelnetA.B.C.Dport<165535>command.
#telnet 10.44.4.74 port 99
Connecting...Connection Refused By Far End
#

Functional Notes
IPaddressesshouldbeexpressedindotteddecimalnotation(forexample,10.10.10.1).The
validrangefortheportis165535.Thedefaultportis23.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42953

6TANV57CLI-35A

2-1029

Total Access/NetVanta Carrier CLI Dictionary

terminal length <0,2-480>


Theterminallength<0480>commandsetsthenumberofrows(lines)foraterminalsession.
Usethenoformofthiscommandtoreturntothedefaultvalue.Thiscommandisonlyvalid
forthecurrentsessionandreturnstothedefault(24rows)whenthesessioncloses.

Usage Examples
Thefollowingisanexampleofhowtousetheterminallength<0,2480>command.
#terminal length 30
#

Functional Notes
Thevalidrangeforthelengthis0480lines.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level1

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),Quad
GPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
65649

2-1030

6TANV57CLI-35A

Section 2, Commands - Common Commands

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191>
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35214

6TANV57CLI-35A

2-1031

Total Access/NetVanta Carrier CLI Dictionary

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191> sorted
Usethetracerouteethernet[<TargetMEPID>|<TargetMACaddress>]sourceWORDWORD
<SourceMEPID>sortedcommandtodiscoverthepaththroughtheEthernetnetworktothe
specifiedMEPusingEthernetCFMlinktraceprotocol.Usingthesortedsyntaxtosortand
displaythetracerouteresultsbyhopcountoncealltheresultsarereceived.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

<18191>

SourceMEPID

Usage Examples
Thefollowingisanexampleofhowtousethetracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>sortedcommand.
#traceroute ethernet 501 source MD_5 MA_5 500 sorted
Type CRTL+C to abort.
TTL 64
Waiting 2000 milliseconds before displaying results sorted by hop count.
Tracing route to Remote MEP 501 from MEP 500
-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

-----------------------------------------------------------------------------1

[00] 00:A0:C8:05:03:00

ingNoTlv

Fwd

[00] 00:A0:C8:2B:8B:EA

egrNoTlv

efm 1

ingOk

egrNoTlv

00:A0:C8:35:58:7E

Term Mep -

RLY_MPDB
RLY_HIT

Destination Remote MEP ID 501 reached at hop 2

Local Security Permissions


Admin,TechSupport

2-1032

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
87641

6TANV57CLI-35A

2-1033

Total Access/NetVanta Carrier CLI Dictionary

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191> ttl <1-255>
Usethetracerouteethernet[<TargetMEPID>|<TargetMACaddress>]sourceWORDWORD
<SourceMEPID>ttl<1255>[fdbonly|sorted]commandtodiscoverthepaththroughthe
EthernetnetworktothespecifiedMEPusingEthernetCFMlinktraceprotocol.TheTTL
parameterconfiguresthemaximumhopsbeforethemessageisdropped.Usethesorted
syntaxtosortanddisplaythetracerouteresultsbyhopcountoncealltheresultsarereceived.
UsethefdbonlysyntaxtoconfigureMIPstoonlyusetheforwardingdatabaseandnotthe
MIPCCMdatabasewhendeterminingiforhowtoforwardaLTMmessage.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

<18191>

SourceMEPID

Usage Examples
Thefollowingisanexampleofhowtousethetracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>ttl<1255>command.
#traceroute ethernet 501 s MD_5 MA_5 500 ttl 50 fdb-only
Type CRTL+C to abort.
TTL 50, Linktrace Timeout is 2000 milliseconds.
Tracing route to Remote MEP 501 from MEP 500
-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

-----------------------------------------------------------------------------1

[00] 00:A0:C8:05:03:00

ingNoTlv

Fwd

[00] 00:A0:C8:2B:8B:EA

egrNoTlv

efm 1

ingOk

egrNoTlv

00:A0:C8:35:58:7E

Term Mep -

RLY_MPDB
RLY_HIT

Destination Remote MEP ID 501 reached at hop 2

Local Security Permissions


Admin,TechSupport

2-1034

6TANV57CLI-35A

Section 2, Commands - Common Commands

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35217

6TANV57CLI-35A

2-1035

Total Access/NetVanta Carrier CLI Dictionary

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191> ttl <1-255> fdb-only
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

<18191>

SourceMEPID

<1255>

TTLvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35219

2-1036

6TANV57CLI-35A

Section 2, Commands - Common Commands

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191> ttl <1-255> fdb-only sorted
Usethetracerouteethernet[<TargetMEPID>|<TargetMACaddress>]sourceWORDWORD
<SourceMEPID>ttl<1255>fdbonlysortedcommandtodiscoverthepaththroughthe
EthernetnetworktothespecifiedMEPusingEthernetCFMlinktraceprotocol.TheTTL
parameterconfiguresthemaximumhopsbeforethemessageisdropped.Thesortedsyntax
willdisplaythetracerouteresultsbyhopcountoncealltheresultsarereceived.Thefdbonly
syntaxtoconfigureMIPstoonlyusetheforwardingdatabaseandnottheMIPCCMdatabase
whendeterminingiforhowtoforwardaLTMmessage.

Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

<18191>

SourceMEPID

<1255>

TTLvalue

Usage Examples
Thefollowingisanexampleofhowtousethetracerouteethernet[xx:xx:xx:xx:xx:xx|<18191>]
sourceWORDWORD<18191>ttl<1255>fdbonlysortedcommand.
#traceroute ethernet 501 s MD_5 MA_5 500 ttl 50 fdb-only sorted
Type CRTL+C to abort.
TTL 50
Waiting 2000 milliseconds before displaying results sorted by hop count.
Tracing route to Remote MEP 501 from MEP 500
-----------------------------------------------------------------------------Hops
Prev Hop
Relay_Action

Ingress

Ingress_Action

Fwd

Egress

Egress_Action

Next Hop

Nexthop

-----------------------------------------------------------------------------1

[00] 00:A0:C8:05:03:00

ingNoTlv

Fwd

[00] 00:A0:C8:2B:8B:EA

egrNoTlv

efm 1

ingOk

egrNoTlv

2
Term Mep -

00:A0:C8:35:58:7E

RLY_MPDB
RLY_HIT

Destination Remote MEP ID 501 reached at hop 2

6TANV57CLI-35A

2-1037

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35220

2-1038

6TANV57CLI-35A

Section 2, Commands - Common Commands

traceroute ethernet [xx:xx:xx:xx:xx:xx|<1-8191>] source


WORD WORD <1-8191> ttl <1-255> sorted
Syntax Description
xx:xx:xx:xx:xx:xx

TargetMACaddress

<18191>

MEPID

WORD

SourceMaintenanceDomain

WORD

SourceMaintenanceAssociation

<18191>

SourceMEPID

<1255>

TTLvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
35218

6TANV57CLI-35A

2-1039

Total Access/NetVanta Carrier CLI Dictionary

write
Usethewritecommandtosaveprovisioningtoflashimmediately.

Usage Examples
Thefollowingisanexampleofhowtousethewritecommand.
#write
Provisioning Saved

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82224

2-1040

6TANV57CLI-35A

Section 2, Commands -

ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#slot-alarm <shelf/slot>
ChassisId(config-slot-alarm x/x)#

Thefollowingisalistofcommandsavailableinthe.
exit
thresholdsheapfreememory<0n>

6TANV57CLI-35A

2-1041

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
136598

2-1042

6TANV57CLI-35A

Section 2, Commands -

thresholds heap free-memory <0-n>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
131460

6TANV57CLI-35A

2-1043

Total Access/NetVanta Carrier CLI Dictionary

ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#mevc * <shelf/slot>
ChassisId(config-mevc name x/x)#

Thefollowingisalistofcommandsavailableinthe.
connectmenportmuxponderhighspeed<shelf/slot/port>
connectmenportmuxponderlaggroup<shelf/slot/group>
connectmenportmuxpondermidspeed<shelf/slot/port>
exit
macswitched
preservecevlan
shutdown
stag<14094>

2-1044

6TANV57CLI-35A

Section 2, Commands -

connect men-port muxponder-highspeed <shelf/slot/port>


Functional Notes
Usetheconnectmenportmuxponderhighspeed<shelf/slot/port>commandtoconfigure
whichmuxponderhighspeedinterfacetheselectedMEVCisappliedto.?Usethenoformof
thiscommandtoremoveanmuxponderhighspeedinterfaceastheMENport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135761

6TANV57CLI-35A

2-1045

Total Access/NetVanta Carrier CLI Dictionary

connect men-port muxponder-lag-group <shelf/slot/group>


Functional Notes
Usetheconnectmenportlaggroup?<shelf/slot/group>commandtoconfigurewhichlag
group?theselectedMEVCisappliedto.?Usethenoformofthiscommandtoremovealag
groupastheMENport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135765

2-1046

6TANV57CLI-35A

Section 2, Commands -

connect men-port muxponder-midspeed <shelf/slot/port>


Functional Notes
Usetheconnectmenportmuxpondermidspeed<shelf/slot/port>commandtoconfigure
whichmuxpondermidspeedinterfacetheselectedMEVCisappliedto.?Usethenoformof
thiscommandtoremoveanmuxpondermidspeedinterfaceastheMENport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135757

6TANV57CLI-35A

2-1047

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135783

2-1048

6TANV57CLI-35A

Section 2, Commands -

mac-switched
Functional Notes
UsethemacswitchedcommandtoenablemacswitchingonanMEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135767

6TANV57CLI-35A

2-1049

Total Access/NetVanta Carrier CLI Dictionary

preserve-ce-vlan
Functional Notes
UsethepreservecevlancommandtoconfiguretheunittopreservetheCEVLANinthe
MEVCaspayload.?UsethenoformofthiscommandtoconfiguretheunittostriptheCE
VLANtagasitismappedtothe?MEVCinthecustomertonetworkdirectionandaddthe
correctCEVLANtaginthenetworktocustomerdirection.IfCEVLANpreservationis
disabledthenonlyoneCEVLANcanbemappedperMEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135766

2-1050

6TANV57CLI-35A

Section 2, Commands -

shutdown
Functional Notes
UsetheshutdowncommandtoadministrativelydisabletheMEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135768

6TANV57CLI-35A

2-1051

Total Access/NetVanta Carrier CLI Dictionary

s-tag <1-4094>
Functional Notes
Usethestag<14094>commandtosettheVIDoftheVLANtagthatisusedtomarktrafficin
theMEVC.?UsethenoformofthecommandtoremovethetagfromtheMEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135753

2-1052

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

ADSL Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface adsl <shelf/slot/port>
ChassisId(config-adsl x/x/x)#

ThefollowingisalistofcommandsavailableintheADSLInterfaceConfigurationCommand
Set.
alarmenablelinkdown
cabinetmode[110|130|250]
descriptionLINE
dmtoptionshambandnotch
dmtoptionssnrmargindownstreammaximum<031>
dmtoptionssnrmargindownstreamminimum<031>
dmtoptionssnrmargindownstreamtarget<031>
dmtoptionssnrmarginupstreammaximum<031>
dmtoptionssnrmarginupstreamminimum<031>
dmtoptionssnrmarginupstreamtarget<031>
exit
latencypathdelaydownstream<0><163>
latencypathdelayupstream<0><163>
latencypathinpdownstream<0><0,0.5,116>
latencypathinpupstream<0><0,0.5,116>
latencypathpayloadratedownstreammaximum<0><3232000>
latencypathpayloadratedownstreamminimum<0><3232000>
latencypathpayloadrateupstreammaximum<0><323776>
latencypathpayloadrateupstreamminimum<0><323776>
latencypathtype<0>[fast|interleave]
rateadaption[fixed|startup]
servicemode[adsl1multimode|adsl2|adsl2+|adsl2+m|adsl2multimode|gdmt|g
lite|glite2|readsl|t1413]
shutdown[maintenance|unassigned]
thresholdsesdownstream15minute<0900>
thresholdsesupstream15minute<0900>
thresholdslofdownstream15minute<0900>
thresholdslofupstream15minute<0900>
thresholdslolupstream15minute<0900>
thresholdslosdownstream15minute<0900>
thresholdslosupstream15minute<0900>

6TANV57CLI-35A

2-1053

Total Access/NetVanta Carrier CLI Dictionary

alarm enable link-down


Functional Notes
Enables/disablesthelinkup/downtrap

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91734

2-1054

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

cabinet-mode [110|130|250]
Cabinetmodeselectsthelowestcarriertoneindex(4.3125KHzpertone)withsignificant
transmittedenergyinthedownstreamdirection.Thisisusedtominimizethemidspan
crosstalkonexistingservicesthatcanoccurwithcabinetinstallations.

Syntax Description
110

Toneindex110(474.375KHz)lowestdownstreamcarrierused

130

Toneindex130(560.625KHz)lowestdownstreamcarrierused

250

Toneindex250(1.078MHz)lowestdownstreamcarrierused

Functional Notes
ActivewhenADSLcabinetdeploymentscenariosareused.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
94222

6TANV57CLI-35A

2-1055

Total Access/NetVanta Carrier CLI Dictionary

description LINE
Usethedescriptioncommandtoidentifythespecifiedinterface(forexample,circuitID,
contactinformation,etc.).Usethenoformofthiscommandtoremoveadescription.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91726

2-1056

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

dmt-options hamband-notch
Functional Notes
Sethambandnotchenables.
1.8Mhz

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
94219

6TANV57CLI-35A

2-1057

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin downstream maximum <0-31>


Functional Notes
setdownstreammaxSNRmarginfrom031dB.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91742

2-1058

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

dmt-options snr-margin downstream minimum <0-31>


Functional Notes
setdownstreamminSNRmarginfrom031dB.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91744

6TANV57CLI-35A

2-1059

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin downstream target <0-31>


Functional Notes
setsthedownstreamtargetsnrmargin(dB)from015.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91746

2-1060

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

dmt-options snr-margin upstream maximum <0-31>


Functional Notes
setupstreammaxSNRmarginfrom031dB.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91749

6TANV57CLI-35A

2-1061

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin upstream minimum <0-31>


Functional Notes
setupstreamminSNRmarginfrom031dB.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91751

2-1062

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

dmt-options snr-margin upstream target <0-31>


Functional Notes
setstheupstreamtargetsnrmargin(dB)from015.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91753

6TANV57CLI-35A

2-1063

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91727

2-1064

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path delay downstream <0> <1-63>


Usethelatencypathdelaydownstream<03><163>commandtoconfigurethemaximum
delayfromtheVTUCtotheVTURallowedforthespecifiedpath.TheVDSL2standardand
legacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportof
multiplechannels/pathswithdifferentdelaycharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathdelaydownstream<0><163>
command.
(config-vdsl 1/19/1)#latency-path delay downstream 0 8
VDSL [1/19/1] Latency Path 0 Max Downstream Delay = 8 ms
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedelayis0to63milliseconds.Thedefaultdelayis8milliseconds.
Ifamaximumdelayvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedtoavalidmaximumlessthantheselectedvalueinoperationonly.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(forexample,R=0,
S<=1,D=1,delaybound<1msec).
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MaxDelay
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.38

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1065

Total Access/NetVanta Carrier CLI Dictionary

Command ID
97239

2-1066

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path delay upstream <0> <1-63>


Usethelatencypathdelayupstream<03><163>commandtoconfigurethemaximumdelay
fromtheVTURtotheVTUCallowedforthespecifiedpath.TheVDSL2standardandlegacy
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithdifferentdelaycharacteristics.

Syntax Description
<0>

EnterLatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathdelayupstream<0><163>
command.
(config-vdsl 1/19/1)#latency-path delay upstream 0 8
VDSL [1/19/1] Latency Path 0 Max Upstream Delay = 8 ms
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedelayis0to63milliseconds.Thedefaultdelayis8milliseconds.
Ifamaximumdelayvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedtoavalidmaximumlessthantheselectedvalueinoperationonly.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(ieR=0,S<=1,D=1,
delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MaxDelay
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.32

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1067

Total Access/NetVanta Carrier CLI Dictionary

Command ID
97242

2-1068

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path inp downstream <0> <0,0.5,1-16>


Usethelatencypathinpdownstream<0><0,0.5,116>commandtoconfiguretheminimum
impulsenoiseprotectiondesiredfromtheATUCtotheATURforthespecifiedpath.The
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithprotectioncharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinpdownstream<0><0,0.5,116>
command.
(config-vdsl 1/19/1)#latency-path inp downstream 0 0.5
VDSL [1/19/1] Latency Path 0 Downstream INP = 0.5
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0.Input0forthepathwhenusingsinglechanneloperation.
ThevalidvaluesfortheINPare0(disabled),0.5,and1to16symbols.ThedefaultINPis0.5
symbols.
IfamimimumINPvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedinoperationtothelargestvaluesupportedbythatmode.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(forexample,R=0,
S<=1,D=1,delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANTAOCTADSL2MIB(adTAOCTADSL2.mi2):adTAOctAdslConfProfileExtEntry
adTAOctAdslAtucConfProfileInterleaveMinInpRev2
OID:1.3.6.1.4.1.664.2.432.2.1.1.7

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1069

Total Access/NetVanta Carrier CLI Dictionary

Command ID
119415

2-1070

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path inp upstream <0> <0,0.5,1-16>


Usethelatencypathinpupstream<0><0,0.5,116>commandtoconfiguretheminimum
impulsenoiseprotectiondesiredfromtheATURtotheATUCforthespecifiedpath.The
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithprotectioncharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinpupstream<0><0,0.5,116>
command.
(config-vdsl 1/19/1)#latency-path inp upstream 0 0.5
VDSL [1/19/1] Latency Path 0 Upstream INP = 0.5
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0.Input0forthepathwhenusingsinglechanneloperation.
ThevalidvaluesfortheINPare0(disabled),0.5,and1to16symbols.ThedefaultINPis0.5
symbols.
IfamimimumINPvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedinoperationtothelargestvaluesupportedbythatmode.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(ieR=0,S<=1,D=1,
delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANTAOCTADSL2MIB(adTAOCTADSL2.mi2):adTAOctAdslConfProfileExtEntry
adTAOctAdslAturConfProfileInterleaveMinInpRev2
OID:1.3.6.1.4.1.664.2.432.2.1.1.8

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1071

Total Access/NetVanta Carrier CLI Dictionary

Command ID
119418

2-1072

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path payload-rate downstream maximum <0> <3232000>


Usethelatencypathpayloadratedownstreammaximum<03><32150000>commandto
configurethemaximumpayloadratefromtheVTUCtotheVTURallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadratedownstream
maximum<0><3232000>command.
(config-vdsl 1/19/1)#latency-path payload-rate downstream maximum 0
100000
VDSL [1/19/1] Latency Path 0 Min Payload Rate Downstream = 100000 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechannel
operation.
Thevalidrangeforthedownstreampayloadrateis32to150,000Kbps.Thedefaultrateis
100,000Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MaxPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.36

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1073

Total Access/NetVanta Carrier CLI Dictionary

Command ID
97246

2-1074

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path payload-rate downstream minimum <0> <3232000>


Usethelatencypathpayloadratedownstreamminimum<03><32150000>commandto
configuretheminimumpayloadratefromtheVTUCtotheVTURallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadratedownstream
minimum<0><3232000>command.
(config-vdsl 1/19/1)#latency-path payload-rate downstream minimum 0 32
VDSL [1/19/1] Latency Path 0 Min Payload Rate Downstream = 32 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedownstreampayloadrateis32to150,000Kbps.Thedefaultrateis32
Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MinPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.37

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

6TANV57CLI-35A

2-1075

Total Access/NetVanta Carrier CLI Dictionary

Command ID
97249

2-1076

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path payload-rate upstream maximum <0> <32-3776>


Usethelatencypathpayloadrateupstreammaximum<03><3296000>commandto
configurethemaximumpayloadratefromtheVTURtotheVTUCallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadrateupstreammaximum
<0><323776>command.
(config-vdsl 1/19/1)#latency-path payload-rate upstream maximum 0 50000
VDSL [1/19/1] Latency Path 0 Max Payload Rate Upstream = 50000 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangefortheupstreampayloadis32to96,000Kbps.Thedefaultpayloadis50,000
Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MaxPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.30

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
97256

6TANV57CLI-35A

2-1077

Total Access/NetVanta Carrier CLI Dictionary

latency-path payload-rate upstream minimum <0> <32-3776>


Thelatencypathpayloadrateupstreamminimum<03><3296000>commandconfiguresthe
minimumpayloadratefromtheVTURtotheVTUCallowedforthespecifiedpath.The
VDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimulta
neoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<0>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadrateupstreamminimum
<0><323776>command.
(config-vdsl 1/19/1)#latency-path payload-rate upstream minimum 0 32
VDSL [1/19/1] Latency Path 0 Min Payload Rate Upstream = 32 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwheresinglechanneloperationisto
beused.
Thevalidrangefortheupstreampayloadrateis32to96,000Kbps.Thedefaultrateis32Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MinPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.31

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
97253

2-1078

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

latency-path type <0> [fast|interleave]


Syntax Description
fast

Settofast

interleave

Settointerleave

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
96477

6TANV57CLI-35A

2-1079

Total Access/NetVanta Carrier CLI Dictionary

rate-adaption [fixed|startup]
Syntax Description
fixed

Setratemodetofixed

startup

Setratemodetoadaptatstartup

Functional Notes
configurerateadaptionup/downshiftmargin,up/downtime,ratemode

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91815

2-1080

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

service-mode [adsl1-multimode|adsl2|adsl2+|adsl2+m|adsl2multimode|g-dmt|g-lite|g-lite2|readsl|t1-413]
Syntax Description
adsl1multimode

SetservicemodetoADSL1Multimode

adsl2

SetservicemodetoADSL2

adsl2+

SetservicemodetoADSL2+

adsl2+m

SetservicemodetoADSL2+AnnexM

adsl2multimode

SetservicemodetoADSL2Multimode

gdmt

SetservicemodetoG.DMT

glite

SetservicemodetoG.LITE

glite2

SetservicemodetoG.LITE2

readsl

SetservicemodetoREADSL

t1413

SetservicemodetoT1.413

Functional Notes
Setthevdslservicemode.
N/A
ADSL2MULTI
T1.413
G.DMT
G.LITE
ADSL2
G.LITE2
ADSL2+
READSL
ADSL1MULTI
ADSL2+M
VDSL1
VDSL2
VDSL2MULTI
TSEMULTI

6TANV57CLI-35A

2-1081

Total Access/NetVanta Carrier CLI Dictionary

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91819

2-1082

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usethenoshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91724

6TANV57CLI-35A

2-1083

Total Access/NetVanta Carrier CLI Dictionary

thresholds es downstream 15-minute <0-900>


Functional Notes
ESthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91704

2-1084

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

thresholds es upstream 15-minute <0-900>


Functional Notes
ESthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91707

6TANV57CLI-35A

2-1085

Total Access/NetVanta Carrier CLI Dictionary

thresholds lof downstream 15-minute <0-900>


Functional Notes
LOFthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91690

2-1086

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

thresholds lof upstream 15-minute <0-900>


Functional Notes
LOFthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91693

6TANV57CLI-35A

2-1087

Total Access/NetVanta Carrier CLI Dictionary

thresholds lol upstream 15-minute <0-900>


Functional Notes
UpstreamLOL15minalarm

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91711

2-1088

6TANV57CLI-35A

Section 2, Commands - ADSL Interface Configuration Command Set

thresholds los downstream 15-minute <0-900>


Functional Notes
LOSSthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91697

6TANV57CLI-35A

2-1089

Total Access/NetVanta Carrier CLI Dictionary

thresholds los upstream 15-minute <0-900>


Functional Notes
LOSSthresholdsvalue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91700

2-1090

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

Application Configuration Command Set


UsetheApplicationConfigurationCommandSettorunvariousapplicationstoconfigure
items,runtestsoninterface,etc.
ChassisId>enable
ChassisId#application
ChassisId(app)#

ThefollowingisalistofcommandsavailableintheApplicationConfigurationCommandSet.
autoinservice<shelf/slot>enable
autoinservice<shelf/slot>timeout<19999>
copyconfigurationinterfaceadslsource<shelf/slot/port>destination<port>|LIST
copyconfigurationinterfacee1source<shelf/slot/port>destination<port>|LIST
copyconfigurationinterfacefxssource<shelf/slot/port>destination<port>|LIST
copyconfigurationinterfaceshdslsource<shelf/slot/port>destination<port>|LIST
copyconfigurationinterfacet1source[<shelf/slot/port>|<shelf/slot/port:chan>]
destination<port>|LIST
copyconfigurationinterfacet3source<shelf/slot/port>destination<port>|LIST
copyconfigurationinterfacevdslsource<shelf/slot/port>destination<port>|LIST
copyconfigurationmodulesource<shelf/slot>destination<shelf/slot>
exit
ezefm<shelf>
securityaccountexpiration<20365>
securitypasswordexpiration<20365>
showtestinterfaceadsl<shelf/slot/port>[delt|selt]
showtestinterfaceadsl<shelf/slot/port>deltdownstream[hlin|hlins|hlog|qln|snr]
showtestinterfaceadsl<shelf/slot/port>deltupstream[hlin|hlins|hlog|qln|snr]
showtestinterfaceadsl<shelf/slot/port>selt[fdr|icn]
showtestinterfacee1<shelf/slot/port>
showtestinterfacehdsl2<shelf/slot/port>tscan
showtestinterfacehdsl2<shelf/slot/port>tscanhtur
showtestinterfacehdsl4<shelf/slot/port>tscan
showtestinterfacehdsl4<shelf/slot/port>tscanhtur
showtestinterfaceshdsl<shelf/slot/port>tscan
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscan
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre1
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre2
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre3
showtestinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhtuc
showtestinterfacet3<shelf/slot/port>

6TANV57CLI-35A

2-1091

Total Access/NetVanta Carrier CLI Dictionary

showtestinterfacevdsl<shelf/slot/port>[delt|selt]
showtestinterfacevdsl<shelf/slot/port>deltdownstream[hlin|hlins|hlog|line
status|qln|snr]
showtestinterfacevdsl<shelf/slot/port>deltupstream[hlin|hlins|hlog|line
status|qln|snr]
showtestinterfacevdsl<shelf/slot/port>selt[fdr|icn]
testalarmrelays<1n>
testinterfaceadsl<shelf/slot/port>[delt|selt]
testinterfaceadsl<shelf/slot/port>deltfilenameWORD
testinterfaceadsl<shelf/slot/port>seltfilenameWORD
testinterfacee1<shelf/slot/port>[clear|inserterror]
testinterfacee1<shelf/slot/port>localloopback[line|payload]
testinterfacee1<shelf/slot/port>localloopbacklinetimeout<09999>
testinterfacee1<shelf/slot/port>localloopbackpayloadtimeout<09999>
testinterfacee1<shelf/slot/port>remotepattern[1in8|all0s|all1s|qrss]
testinterfacee1<shelf/slot/port>remotepattern1in8loopbacknone
testinterfacee1<shelf/slot/port>remotepattern1in8loopbacknonetimeout<09999>
testinterfacee1<shelf/slot/port>remotepatternall0sloopbacknone
testinterfacee1<shelf/slot/port>remotepatternall0sloopbacknonetimeout<09999>
testinterfacee1<shelf/slot/port>remotepatternall1sloopbacknone
testinterfacee1<shelf/slot/port>remotepatternall1sloopbacknonetimeout<09999>
testinterfacee1<shelf/slot/port>remotepatternqrssloopbacknone
testinterfacee1<shelf/slot/port>remotepatternqrssloopbacknonetimeout<09999>
testinterfacehdsl2<shelf/slot/port>tscan
testinterfacehdsl2<shelf/slot/port>tscanhtur
testinterfacehdsl4<shelf/slot/port>tscan
testinterfacehdsl4<shelf/slot/port>tscanhtur
testinterfaceshdsl<shelf/slot/port>psd<389><34>
testinterfaceshdsl<shelf/slot/port>tscan
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]clear
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]inserterror
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]localloopbackline
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]localloopbacklinetimeout<0
9999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]localloopbackpayload
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]localloopbackpayloadtimeout
<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackcsu

2-1092

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackcsu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackfdl
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackfdl
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopback
feac
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopback
feactimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackniu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopbackniu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopback
none
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepattern1in8loopback
nonetimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0s
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackcsu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackcsu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackfdl
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackfdl
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopback
feac
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopback
feactimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackniu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopbackniu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopback
none
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall0sloopback
nonetimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1s
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackcsu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackcsu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackfdl
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackfdl
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopback
feac

6TANV57CLI-35A

2-1093

Total Access/NetVanta Carrier CLI Dictionary

testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopback
feactimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackniu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopbackniu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopback
none
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternall1sloopback
nonetimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrss
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackcsu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackcsu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackfdl
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackfdl
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackfeac
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackfeac
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackniu
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopbackniu
timeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopback
none
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]remotepatternqrssloopback
nonetimeout<09999>
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscan
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre1
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre2
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhre3
testinterfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]tscanhtuc
testinterfacet3<shelf/slot/port>[clear|inserterror]
testinterfacet3<shelf/slot/port>localloopbackline
testinterfacet3<shelf/slot/port>localloopbacklinetimeout<09999>
testinterfacet3<shelf/slot/port>remotepattern[p215|p220|p223]
testinterfacet3<shelf/slot/port>remotepatternp215loopback[line|none]
testinterfacet3<shelf/slot/port>remotepatternp215loopbacklinetimeout<09999>
testinterfacet3<shelf/slot/port>remotepatternp215loopbacknonetimeout<09999>
testinterfacet3<shelf/slot/port>remotepatternp220loopback[line|none]
testinterfacet3<shelf/slot/port>remotepatternp220loopbacklinetimeout<09999>
testinterfacet3<shelf/slot/port>remotepatternp220loopbacknonetimeout<09999>
testinterfacet3<shelf/slot/port>remotepatternp223loopback[line|none]

2-1094

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

testinterfacet3<shelf/slot/port>remotepatternp223loopbacklinetimeout<09999>
testinterfacet3<shelf/slot/port>remotepatternp223loopbacknonetimeout<09999>
testinterfacevdsl<shelf/slot/port>[delt|selt]
testinterfacevdsl<shelf/slot/port>deltfilenameWORD
testinterfacevdsl<shelf/slot/port>seltfilenameWORD
validateradiusserverhostA.B.C.DusernameWORDpassword
validatetacacsserverhostA.B.C.DusernameWORDpassword

6TANV57CLI-35A

2-1095

Total Access/NetVanta Carrier CLI Dictionary

auto-in-service <shelf/slot> enable


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFME1AM(1188802G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
104400

2-1096

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

auto-in-service <shelf/slot> timeout <1-9999>


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFME1AM(1188802G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
104401

6TANV57CLI-35A

2-1097

Total Access/NetVanta Carrier CLI Dictionary

copy configuration interface adsl source <shelf/slot/port>


destination <port>|LIST
Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
92107

2-1098

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

copy configuration interface e1 source <shelf/slot/port>


destination <port>|LIST
Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1CEM32PortAM(1188801G1)

Command ID
90216

6TANV57CLI-35A

2-1099

Total Access/NetVanta Carrier CLI Dictionary

copy configuration interface fxs source <shelf/slot/port>


destination <port>|LIST
Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
97297

2-1100

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

copy configuration interface shdsl source <shelf/slot/port>


destination <port>|LIST
Usethecopyconfigurationinterfaceshdslsource<shelf/slot/port>destinationLISTcommand
tocopytheconfigurationofasingleSHDSLporttoalistofdesiredSHDSLportsonthesame
SHDSLaccessmodule.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethecopyconfigurationinterfaceshdslsource
<shelf/slot/port>destination<port>|LISTcommand.
(app)#copy configuration interface shdsl source 1/2/1 destination 216,21,26
(app)#

Functional Notes
Usethe<shelf/slot/port>inputtoselecttheSHDSLportfromwhichtheconfigurationis
copied.
UsetheLISTinputtoenterthelistofselectedports.TheLISTinputisacommadelimited
numericlistwithoutspaces.Theinputcanincluderanges.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
79199

6TANV57CLI-35A

2-1101

Total Access/NetVanta Carrier CLI Dictionary

copy configuration interface t1 source [<shelf/slot/port>|<shelf/


slot/port:chan>] destination <port>|LIST
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1)

Command ID
79205

2-1102

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

copy configuration interface t3 source <shelf/slot/port>


destination <port>|LIST
Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1)

Command ID
79212

6TANV57CLI-35A

2-1103

Total Access/NetVanta Carrier CLI Dictionary

copy configuration interface vdsl source <shelf/slot/port>


destination <port>|LIST
Usethecopyconfigurationinterfacevdslsource<shelf/slot/port>destination<x,yz,a>
commandtocopytheconfigurationofasingleVDSLporttoalistofdesiredportsonthesame
accessmodule.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethecopyconfigurationinterfacevdslsource<shelf/
slot/port>destination<port>|LISTcommand.
(app)#copy configuration interface vdsl source 1/2/1 destination 216,21,26
(app)#

Functional Notes
Usethe<shelf/slot/port>inputtoselecttheVDSLportfromwhichtheconfigurationiscopied.
Usethe<x,yz,a>inputtoenterthelistofselectedports.Theinputisacommadelimited
numericlistwithoutspaces.Theinputcanincluderanges.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
83282

2-1104

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

copy configuration module source <shelf/slot> destination


<shelf/slot>
Usethecopyconfigurationmodulesource<shelf/slot>destination<shelf/slot>commandto
copyprovisioningfromonemoduletoanothermodule.

Syntax Description
<shelf/slot>

Specifiedmodule

Usage Examples
Thefollowingisanexampleofhowtousethecopyconfigurationmodulesource<shelf/slot>
destination<shelf/slot>command.
(app)#copy configuration module source 1/1 destination 1/3
(app)#

Functional Notes
Usethe<shelf/slot>inputstodesignatethesourceanddestinationmodules.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
79194

6TANV57CLI-35A

2-1105

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFME1AM(1188802G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),E1CEM32PortAM(1188801G1),DS1FrameRelay32
PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42344

2-1106

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

ez-efm <shelf>
Usetheezefm<shelf>commandtoactivatetheEZEFMApplicationCommandSetforthe
specifiedshelf.TheEZBridgeapplicationisusedtocreateandmodifyEFMgroups.The
applicationtakesadvantageofaresourcesharingalgorithmthatstrategicallyassignsEFM
groupstoevenlydistributetheworkloadofmanagingEFMgroups.

Usage Examples
Thefollowingisanexampleofhowtousetheezefm<shelf>command.
(app)#ez-efm 1
(app-ez-efm 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
61946

6TANV57CLI-35A

2-1107

Total Access/NetVanta Carrier CLI Dictionary

security account-expiration <20-365>


Usethesecurityaccountexpiration<20365>commandtosettheaccountexpirationtime.The
accountexpirationtimeisthenumberofdaysofinactivityuntiltheaccountexpires.Usethe
noformofthiscommandtosettheaccountexpirationtimetothedefaultsettingof90days.

Usage Examples
Thefollowingisanexampleofhowtousethesecurityaccountexpiration<20365>command.
(app)#security account-expiration 365
(app)#

Functional Notes
Thevalidrangefortheexpirationtimeis20to365days.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64589

2-1108

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

security password-expiration <20-365>


Usethesecuritypasswordexpiration<20365>commandtosetthepasswordexpirationtime
forallprivilegelevels.

Usage Examples
Thefollowingisanexampleofhowtousethesecuritypasswordexpiration<20365>
command.
(app)#security password-expiration 365
(app)#

Functional Notes
Thevalidrangefortheexpirationtimeis20to365days.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64651

6TANV57CLI-35A

2-1109

Total Access/NetVanta Carrier CLI Dictionary

show test interface adsl <shelf/slot/port> [delt|selt]


Syntax Description
delt

ShowthestatusofthecurrentDELTtest

selt

ShowthestatusofthecurrentSELTtest

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
94973

2-1110

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface adsl <shelf/slot/port> delt downstream


[hlin|hlins|hlog|qln|snr]
Syntax Description
<shelf/slot/port>

Specifiedinterface

hlin

H(f)linearrepresentation

hlins

H(f)linearrepresentationscale

hlog

H(f)logarithmicrepresentation

qln

QuietLineNoise

snr

SignaltoNoiseRatio

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
95514

6TANV57CLI-35A

2-1111

Total Access/NetVanta Carrier CLI Dictionary

show test interface adsl <shelf/slot/port> delt upstream


[hlin|hlins|hlog|qln|snr]
Syntax Description
<shelf/slot/port>

Specifiedinterface

hlin

H(f)linearrepresentation

hlins

H(f)linearrepresentationscale

hlog

H(f)logarithmicrepresentation

qln

QuietLineNoise

snr

SignaltoNoiseRatio

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
95508

2-1112

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface adsl <shelf/slot/port> selt [fdr|icn]


Syntax Description
<shelf/slot/port>

Specifiedinterface

selt

ShowthestatusofthecurrentSELTtest

fdr

FrequencyDomainResponse

icn

IdleChannelNoise

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
94960

6TANV57CLI-35A

2-1113

Total Access/NetVanta Carrier CLI Dictionary

show test interface e1 <shelf/slot/port>


Local Security Permissions
Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
45699

2-1114

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface hdsl2 <shelf/slot/port> tscan


Syntax Description
<shelf/slot/port>

SelecttheHDSL2interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
86872

6TANV57CLI-35A

2-1115

Total Access/NetVanta Carrier CLI Dictionary

show test interface hdsl2 <shelf/slot/port> tscan htur


Syntax Description
<shelf/slot/port>

SelecttheHDSL2interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
86874

2-1116

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface hdsl4 <shelf/slot/port> tscan


Syntax Description
<shelf/slot/port>

SelecttheHDSL4interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
86880

6TANV57CLI-35A

2-1117

Total Access/NetVanta Carrier CLI Dictionary

show test interface hdsl4 <shelf/slot/port> tscan htur


Syntax Description
<shelf/slot/port>

SelecttheHDSL4interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
86882

2-1118

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface shdsl <shelf/slot/port> tscan


Usetheshowtestinterfaceshdsl<shelf/slot/port>tscancommandtoviewtheresultsofthe
lastTSCANtestperformedonthespecifiedinterface.

Syntax Description
<shelf/slot/port>

SelecttheSHDSLinterface

Usage Examples
Thefollowingisasampleoutputoftheshowtestinterfaceshdsl<shelf/slot/port>tscan
command.
(app)#show test interface shdsl 1/0/1 tscan
SHDSL 1/0/1 TSCAN Results
Date/Time

: 12/16/2008 15:13:38

Status

: Done

Rate

: 32 DS0s

Distance

: 2090 ft

Fault

: Open

(app)#

Functional Notes
Usethe<shelf/slot/port>inputtospecifytheSHDSLinterface.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
86869

6TANV57CLI-35A

2-1119

Total Access/NetVanta Carrier CLI Dictionary

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


Usetheshowtestinterfacet1<shelf/slot/port>commandtodisplaythestatusofatestappli
cationonthespecifiedT1interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45759

2-1120

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


tscan
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
129825

6TANV57CLI-35A

2-1121

Total Access/NetVanta Carrier CLI Dictionary

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


tscan hre1
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
129828

2-1122

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


tscan hre2
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
129829

6TANV57CLI-35A

2-1123

Total Access/NetVanta Carrier CLI Dictionary

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


tscan hre3
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
129830

2-1124

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


tscan htuc
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
129826

6TANV57CLI-35A

2-1125

Total Access/NetVanta Carrier CLI Dictionary

show test interface t3 <shelf/slot/port>


Usetheshowtestinterfacet3<shelf/slot/port>commandtodisplaythestatusofatestappli
cationonthespecifiedT3interface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42354

2-1126

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface vdsl <shelf/slot/port> [delt|selt]


Syntax Description
delt

ShowthestatusofthecurrentDELTtest

selt

ShowthestatusofthecurrentSELTtest

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
95520

6TANV57CLI-35A

2-1127

Total Access/NetVanta Carrier CLI Dictionary

show test interface vdsl <shelf/slot/port> delt downstream


[hlin|hlins|hlog|line-status|qln|snr]
Syntax Description
<shelf/slot/port>

Specifiedinterface

hlin

H(f)linearrepresentation

hlins

H(f)linearrepresentationscale

hlog

H(f)logarithmicrepresentation

linestatus

Linestateinformation

qln

QuietLineNoise

snr

SignaltoNoiseRatio

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
95541

2-1128

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

show test interface vdsl <shelf/slot/port> delt upstream


[hlin|hlins|hlog|line-status|qln|snr]
Syntax Description
<shelf/slot/port>

Specifiedinterface

hlin

H(f)linearrepresentation

hlins

H(f)linearrepresentationscale

hlog

H(f)logarithmicrepresentation

linestatus

Linestateinformation

qln

QuietLineNoise

snr

SignaltoNoiseRatio

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
95535

6TANV57CLI-35A

2-1129

Total Access/NetVanta Carrier CLI Dictionary

show test interface vdsl <shelf/slot/port> selt [fdr|icn]


Syntax Description
<shelf/slot/port>

Specifiedinterface

selt

ShowthestatusofthecurrentSELTtest

fdr

FrequencyDomainResponse

icn

IdleChannelNoise

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
95521

2-1130

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test alarm-relays <1-n>


Usethetestalarmrelays<1n>commandtoactivatetheRelayTestApplicationCommandSet
forthespecifiedshelf.

Usage Examples
Thefollowingisanexampleofhowtousethetestalarmrelays<1n>command.
(app)#test alarm-relays 1
(app-tst-relay shelf 1)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87235

6TANV57CLI-35A

2-1131

Total Access/NetVanta Carrier CLI Dictionary

test interface adsl <shelf/slot/port> [delt|selt]


Syntax Description
delt

RunaDualEndedLoopTest

selt

RunaSingleEndedLoopTest

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
94953

2-1132

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface adsl <shelf/slot/port> delt filename WORD


Syntax Description
<shelf/slot/port>

SelecttheADSLinterfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
101948

6TANV57CLI-35A

2-1133

Total Access/NetVanta Carrier CLI Dictionary

test interface adsl <shelf/slot/port> selt filename WORD


Syntax Description
<shelf/slot/port>

SelecttheADSLinterfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
101946

2-1134

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> [clear|insert-error]


Syntax Description
clear

Clearstatisticsassociatedwiththetestonthisinterface

inserterror

Insertasinglebiterrorintothepatterngeneration

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77693

6TANV57CLI-35A

2-1135

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> local loopback [line|payload]


Syntax Description
<shelf/slot/port>

SelecttheE1interface

line

Activatealoopbackoftheentirephysicalinterface

payload

Activatealoopbackofalldataexceptforframingbits

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77695

2-1136

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> local loopback line timeout


<0-9999>
Usethetestinterfacee1localloopbacklinetimeoutcommandtosetatimeoutonthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>localloopback
linetimeout<09999>command.
(app)#test interface e1 1/0/1 local loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77701

6TANV57CLI-35A

2-1137

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> local loopback payload


timeout <0-9999>
Usethetestinterfacee1localloopbackpayloadtimeoutcommandtosetatimeoutonthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>localloopback
payloadtimeout<09999>command.
(app)#test interface e1 1/0/1 local loopback payload timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77698

2-1138

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> remote pattern


[1in8|all0s|all1s|qrss]
Usethetestinterfacee1remotepatterncommandtoenabletestpatterngenerationtowards
theunitattheotherendofthisphysicalinterface

Syntax Description
<shelf/slot/port>

SelecttheE1interface

1in8

Specifythetestpatternas1in8

all0s

Specifythetestpatternasframedallzeros

all1s

Specifythetestpatternasframedallones

qrss

SpecifythetestpatternasQRSS

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98633

6TANV57CLI-35A

2-1139

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> remote pattern 1in8 loopback


none
Usethetestinterfacee1remotepattern1in8loopbacknonecommandtosendatestpatternof
1in8.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
1in8loopbacknonecommand.
(app)#test interface e1 1/0/1 remote pattern 1in8 loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98651

2-1140

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> remote pattern 1in8 loopback


none timeout <0-9999>
Usethetestinterfacee1remotepattern1in8loopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
1in8loopbacknonetimeout<09999>command.
(app)#test interface e1 1/0/1 remote pattern 1in8 loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98653

6TANV57CLI-35A

2-1141

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> remote pattern all0s


loopback none
Usethetestinterfacee1remotepatternall0sloopbacknonecommandtosendatestpatternof
allzeros.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
all0sloopbacknonecommand.
(app)#test interface e1 1/0/1 remote pattern all0s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98646

2-1142

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> remote pattern all0s


loopback none timeout <0-9999>
Usethetestinterfacee1remotepatternall0sloopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
all0sloopbacknonetimeout<09999>command.
(app)#test interface e1 1/0/1 remote pattern all0s loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98648

6TANV57CLI-35A

2-1143

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> remote pattern all1s


loopback none
Usethetestinterfacee1remotepatternall1sloopbacknonecommandtosendatestpatternof
allones.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
all1sloopbacknonecommand.
(app)#test interface e1 1/0/1 remote pattern all1s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98641

2-1144

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> remote pattern all1s


loopback none timeout <0-9999>
Usethetestinterfacee1remotepatternall1sloopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
all1sloopbacknonetimeout<09999>command.
(app)#test interface e1 1/0/1 remote pattern all1s loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98643

6TANV57CLI-35A

2-1145

Total Access/NetVanta Carrier CLI Dictionary

test interface e1 <shelf/slot/port> remote pattern qrss loopback


none
Usethetestinterfacee1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
qrssloopbacknonecommand.
(app)#test interface e1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98636

2-1146

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface e1 <shelf/slot/port> remote pattern qrss loopback


none timeout <0-9999>
Usethetestinterfacee1remotepatternqrssloopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheE1interface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacee1<shelf/slot/port>remotepattern
qrssloopbacknonetimeout<09999>command.
(app)#test interface e1 1/0/1 remote pattern qrss loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1)

Command ID
98638

6TANV57CLI-35A

2-1147

Total Access/NetVanta Carrier CLI Dictionary

test interface hdsl2 <shelf/slot/port> tscan


Syntax Description
<shelf/slot/port>

SelecttheHDSL2interfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
79276

2-1148

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface hdsl2 <shelf/slot/port> tscan htur


Syntax Description
<shelf/slot/port>

SelecttheHDSL2interfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
86705

6TANV57CLI-35A

2-1149

Total Access/NetVanta Carrier CLI Dictionary

test interface hdsl4 <shelf/slot/port> tscan


Syntax Description
<shelf/slot/port>

SelecttheHDSL4interfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
79280

2-1150

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface hdsl4 <shelf/slot/port> tscan htur


Syntax Description
<shelf/slot/port>

SelecttheHDSL4interfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
86710

6TANV57CLI-35A

2-1151

Total Access/NetVanta Carrier CLI Dictionary

test interface shdsl <shelf/slot/port> psd <3-89> <3-4>


Usethetestinterfaceshdsl<shelf/slot/port>tscancommandtobeginanintrusiveTSCANtest
onthespecifiedinterface.Thetestbringsdowntheinterfaceuntilthetestiscomplete.

Syntax Description
<shelf/slot/port>

SelecttheSHDSLinterfacetoruntheapplication

<389>

NumberofDS0s(Nx64k)

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfaceshdsl<shelf/slot/port>psd<389>
<34>command.
(app)#test interface shdsl 1/0/3 tscan
Status: Accumulating Data.....................Done
SHDSL 1/0/3 TSCAN Results
Date/Time

: 12/16/2008 15:13:38

Status

: Done

Rate

: 32 DS0s

Distance

: 2090 ft

Fault

: Open

(app)#

Functional Notes
Usethe<shelf/slot/port>inputtoselecttheSHDSLinterface.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV
838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA
838(1200633G7)

Command ID
96355

2-1152

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface shdsl <shelf/slot/port> tscan


Usethetestinterfaceshdsl<shelf/slot/port>tscancommandtobeginanintrusiveTSCANtest
onthespecifiedinterface.Thetestbringsdowntheinterfaceuntilthetestiscomplete.

Syntax Description
<shelf/slot/port>

SelecttheSHDSLinterfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfaceshdsl<shelf/slot/port>tscan
command.
(app)#test interface shdsl 1/0/3 tscan
Status: Accumulating Data.....................Done
SHDSL 1/0/3 TSCAN Results
Date/Time

: 12/16/2008 15:13:38

Status

: Done

Rate

: 32 DS0s

Distance

: 2090 ft

Fault

: Open

(app)#

Functional Notes
Usethe<shelf/slot/port>inputtoselecttheSHDSLinterface.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42499

6TANV57CLI-35A

2-1153

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] clear


Usethetestinterfacet1clearcommandtoclearstatisticsassociatedwiththetestonaT1
interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]clearcommand.
(app)#test interface t1 1/0/1 clear
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45733

2-1154

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


insert-error
Usethetestinterfacet1<shelf/slot/port>inserterrorcommandtoinsertanerrorintothetest
runningonthespecifiedT1interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]inserterrorcommand.
(app)#test interface t1 1/0/1 insert-error
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
90047

6TANV57CLI-35A

2-1155

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local


loopback line
Usethetestinterfacet1localloopbacklinecommandtoinitiatealoopbackofalldata,
includingframing,ontheT1interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]localloopbacklinecommand.
(app)#test interface t1 1/0/1 local loopback line
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45736

2-1156

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local


loopback line timeout <0-9999>
Usethetestinterfacet1localloopbacklinetimeoutcommandtosetatimeoutonthetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]localloopbacklinetimeout<09999>command.
(app)#test interface t1 1/0/1 local loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45738

6TANV57CLI-35A

2-1157

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local


loopback payload
Usethetestinterfacet1localloopbackpayloadcommandtoinitiatealoopbackofalldata
reframedlocallyontheT1interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]localloopbackpayloadcommand.
(app)#test interface t1 1/0/1 local loopback payload
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45739

2-1158

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] local


loopback payload timeout <0-9999>
Usethetestinterfacet1localloopbackpayloadtimeoutcommandtosetatimeoutonthetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]localloopbackpayloadtimeout<09999>command.
(app)#test interface t1 1/0/1 local loopback payload timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45741

6TANV57CLI-35A

2-1159

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82015

2-1160

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback csu
Usethetestinterfacet1remotepattern1in8loopbackcsucommandtosendacsuremote
loopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89591

6TANV57CLI-35A

2-1161

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback csu timeout <0-9999>
Usethetestinterfacet1remotepattern1in8loopbackcsutimeout<09999>commandtosend
acsuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89593

2-1162

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback fdl
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82017

6TANV57CLI-35A

2-1163

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback fdl timeout <0-9999>
Usethetestinterfacet1remotepattern1in8loopbackfdltimeout<09999>commandtosenda
fdlremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82019

2-1164

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback feac
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepattern1in8loopbackfeaccommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91572

6TANV57CLI-35A

2-1165

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback feac timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepattern1in8loopbackfeactimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91574

2-1166

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback niu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89594

6TANV57CLI-35A

2-1167

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback niu timeout <0-9999>
Usethetestinterfacet1remotepattern1in8loopbackniutimeout<09999>commandtosend
aniuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89596

2-1168

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback none
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82020

6TANV57CLI-35A

2-1169

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern 1in8 loopback none timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepattern1in8loopbacknonetimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
91564

2-1170

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s
Usethetestinterfacet1remotepatternall0scommandtosendatestpatternofallzerosonthis
interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0scommand.
(app)#test interface t1 1/0/1 remote pattern all0s
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82009

6TANV57CLI-35A

2-1171

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback csu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89638

2-1172

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback csu timeout <0-9999>
Usethetestinterfacet1remotepatternall0sloopbackcsutimeout<09999>commandtosend
acsuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89640

6TANV57CLI-35A

2-1173

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback fdl
Usethetestinterfacet1remotepatternall0sloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofallzeros.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbackfdlcommand.
(app)#test interface t1 1/0/1 remote pattern all0s loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern all0s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82011

2-1174

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback fdl timeout <0-9999>
Usethetestinterfacet1remotepatternall0sloopbackfdltimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbackfdltimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern all0s loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82013

6TANV57CLI-35A

2-1175

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback feac
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbackfeaccommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91569

2-1176

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback feac timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbackfeactimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91571

6TANV57CLI-35A

2-1177

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback niu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89641

2-1178

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback niu timeout <0-9999>
Usethetestinterfacet1remotepatternall0sloopbackniutimeout<09999>commandtosend
aniuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89643

6TANV57CLI-35A

2-1179

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback none
Usethetestinterfacet1remotepatternall0sloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofallzeros.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbacknonecommand.
(app)#test interface t1 1/0/1 remote pattern all0s loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern all0s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
82014

2-1180

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all0s loopback none timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall0sloopbacknonetimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
91562

6TANV57CLI-35A

2-1181

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s
Usethetestinterfacet1remotepatternall1scommandtosendatestpatternofallonesonthis
interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1scommand.
(app)#test interface t1 1/0/1 remote pattern all1s
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45750

2-1182

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback csu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89644

6TANV57CLI-35A

2-1183

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback csu timeout <0-9999>
Usethetestinterfacet1remotepatternall1sloopbackcsutimeout<09999>commandtosend
acsuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89646

2-1184

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback fdl
Usethetestinterfacet1remotepatternall1sloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofallones.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbackfdlcommand.
(app)#test interface t1 1/0/1 remote pattern all1s loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern all1s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45752

6TANV57CLI-35A

2-1185

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback fdl timeout <0-9999>
Usethetestinterfacet1remotepatternall1sloopbackfdltimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbackfdltimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern all1s loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45754

2-1186

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback feac
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbackfeaccommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91566

6TANV57CLI-35A

2-1187

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback feac timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbackfeactimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91568

2-1188

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback niu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89647

6TANV57CLI-35A

2-1189

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback niu timeout <0-9999>
Usethetestinterfacet1remotepatternall1sloopbackniutimeout<09999>commandtosend
aniuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89649

2-1190

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback none
Usethetestinterfacet1remotepatternall1sloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofallones.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbacknonecommand.
(app)#test interface t1 1/0/1 remote pattern all1s loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern all1s loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45755

6TANV57CLI-35A

2-1191

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern all1s loopback none timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternall1sloopbacknonetimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
91560

2-1192

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss
Usethetestinterfacet1remotepatternqrsscommandtosendatestpatternofQRSSonthis
interface.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrsscommand.
(app)#test interface t1 1/0/1 remote pattern qrss
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45744

6TANV57CLI-35A

2-1193

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback csu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89650

2-1194

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback csu timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackcsutimeout<09999>commandtosend
acsuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89652

6TANV57CLI-35A

2-1195

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback fdl
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbackfdlcommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45746

2-1196

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback fdl timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbackfdltimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45748

6TANV57CLI-35A

2-1197

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback feac
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbackfeaccommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91554

2-1198

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback feac timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbackfeactimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),CHDS3FrameRelay3Port
AM(1187220G3)

Command ID
91556

6TANV57CLI-35A

2-1199

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback niu
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89653

2-1200

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback niu timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackniutimeout<09999>commandtosend
aniuremoteloopbackcommand

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
89655

6TANV57CLI-35A

2-1201

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback none
Usethetestinterfacet1remotepatternqrssloopbackcommandtosendaremoteloopback
requestandthensendatestpatternofQRSS.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbacknonecommand.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl
(app)#
(app)#test interface t1 1/0/1 remote pattern qrss loopback none
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45749

2-1202

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]


remote pattern qrss loopback none timeout <0-9999>
Usethetestinterfacet1remotepatternqrssloopbackfdltimeoutcommandtosetatimeouton
thetest.

Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]remotepatternqrssloopbacknonetimeout<09999>command.
(app)#test interface t1 1/0/1 remote pattern qrss loopback fdl timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
91558

6TANV57CLI-35A

2-1203

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan


Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
118707

2-1204

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan


hre1
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
118710

6TANV57CLI-35A

2-1205

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan


hre2
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
118711

2-1206

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan


hre3
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
118712

6TANV57CLI-35A

2-1207

Total Access/NetVanta Carrier CLI Dictionary

test interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>] tscan


htuc
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
118708

2-1208

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> [clear|insert-error]


Usethetestinterfacet3<shelf/slot/port>commandstorunatestorclearteststatistics/insert
anerrorintoatestrunningonthespecifiedT3interface.

Syntax Description
clear

Clearstatisticsassociatedwiththetestonthisinterface

inserterror

Insertasinglebiterrorintothepatterngeneration

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42358

6TANV57CLI-35A

2-1209

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> local loopback line


Usethetestinterfacet3localloopbacklinecommandtoinitiatealoopbackofalldata,
includingframing,ontheT3interface.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>localloopback
linecommand.
(app)#test interface t3 1/0/1 local loopback line
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42362

2-1210

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> local loopback line timeout


<0-9999>
Usethetestinterfacet3localloopbacklinetimeoutcommandtosetatimeoutonthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>localloopback
linetimeout<09999>command.
(app)#test interface t3 1/0/1 local loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42364

6TANV57CLI-35A

2-1211

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> remote pattern


[p215|p220|p223]
Usethetestinterfacet3remotepatterncommandstoenabletestpatterngenerationtowards
theunitattheotherendofthisphysicalinterface.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

p215

Setthetestpatternusedto2^15

p220

Setthetestpatternusedto2^20

p223

Setthetestpatternusedto2^23

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42369

2-1212

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> remote pattern p215


loopback [line|none]
Usethetestinterfacet3remotepatternp215loopbackcommandtosenda2^15testpatternon
aT3interface.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

line

Requestaloopbackoftheentirephysicalinterface

none

Specifythatnoloopbackisrequested

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42371

6TANV57CLI-35A

2-1213

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> remote pattern p215


loopback line timeout <0-9999>
Usethetestinterfacet3remotepatternp215loopbacklinetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p215loopbacklinetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p215 loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42374

2-1214

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> remote pattern p215


loopback none timeout <0-9999>
Usethetestinterfacet3remotepatternp215loopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p215loopbacknonetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p215 loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42377

6TANV57CLI-35A

2-1215

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> remote pattern p220


loopback [line|none]
Usethetestinterfacet3remotepatternp220loopbackcommandtosenda2^20testpatternon
aT3interface.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

line

Requestaloopbackoftheentirephysicalinterface

none

Specifythatnoloopbackisrequested

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42379

2-1216

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> remote pattern p220


loopback line timeout <0-9999>
Usethetestinterfacet3remotepatternp220loopbacklinetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p220loopbacklinetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p220 loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42382

6TANV57CLI-35A

2-1217

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> remote pattern p220


loopback none timeout <0-9999>
Usethetestinterfacet3remotepatternp220loopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p220loopbacknonetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p220 loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42385

2-1218

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> remote pattern p223


loopback [line|none]
Usethetestinterfacet3remotepatternp223loopbackcommandtosenda2^23testpatternon
aT3interface.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

line

Requestaloopbackoftheentirephysicalinterface

none

Specifythatnoloopbackisrequested

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42387

6TANV57CLI-35A

2-1219

Total Access/NetVanta Carrier CLI Dictionary

test interface t3 <shelf/slot/port> remote pattern p223


loopback line timeout <0-9999>
Usethetestinterfacet3remotepatternp223loopbacklinetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p223loopbacklinetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p223 loopback line timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42390

2-1220

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface t3 <shelf/slot/port> remote pattern p223


loopback none timeout <0-9999>
Usethetestinterfacet3remotepatternp223loopbacknonetimeoutcommandtosetatimeout
onthetest.

Syntax Description
<shelf/slot/port>

SelecttheT3interfacetoruntheapplication

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacet3<shelf/slot/port>remotepattern
p223loopbacknonetimeout<09999>command.
(app)#test interface t3 1/0/1 remote pattern p223 loopback none timeout 5
(app)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42393

6TANV57CLI-35A

2-1221

Total Access/NetVanta Carrier CLI Dictionary

test interface vdsl <shelf/slot/port> [delt|selt]


Usethetestinterfacevdsl<shelf/slot/port>[delt|selt]commandtoinitiatethedesired
diagnostictestontheindicatedshelf,slot,andport.

Syntax Description
delt

RunaDualEndedLoopTest

selt

RunaSingleEndedLoopTest

Usage Examples
Thefollowingisanexampleofhowtousethetestinterfacevdsl<shelf/slot/port>[delt|selt]
command.
(app)#test interface vdsl 1/2/2 delt
(app)#

Functional Notes
TheSELTdiagnostictestinitiatesonanunterminatedloop.
TheDELTdiagnosticisapplicableonlywhentheportisinshowtimeandtheservicemode
supportsDELT.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
78684

2-1222

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

test interface vdsl <shelf/slot/port> delt filename WORD


Syntax Description
<shelf/slot/port>

SelecttheVDSLinterfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
101944

6TANV57CLI-35A

2-1223

Total Access/NetVanta Carrier CLI Dictionary

test interface vdsl <shelf/slot/port> selt filename WORD


Syntax Description
<shelf/slot/port>

SelecttheVDSLinterfacetoruntheapplication

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
101942

2-1224

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

validate radius-server host A.B.C.D username WORD


password
Syntax Description
A.B.C.D

IPAddress

WORD

Username

Usage Examples
ThefollowingisanexampleofhowtousethevalidateradiusserverhostA.B.C.Dusername
WORDpasswordcommand.
tacacs-server host <ip>
tacacs-server host <ip> key <key>
tacacs-server host <ip> key <key> port <port>
tacacs-server host <ip> key <key> timeout <timeout>
tacacs-server host <ip> key <key> port <port> timeout <timeout>
tacacs-server host <ip> key <key> timeout <timeout> port <port>
tacacs-server host <ip> timeout <timeout>
tacacs-server host <ip> timeout <timeout> key <key>
tacacs-server host <ip> timeout <timeout> key <key> port <port>
tacacs-server host <ip> timeout <timeout> port <port> key <key>
tacacs-server host <ip> port <port>
tacacs-server host <ip> port <port> key <key>
tacacs-server host <ip> port <port> timeout <timeout>
tacacs-server host <ip> port <port> key <key> timeout <timeout>
tacacs-server host <ip> port <port> timeout <timeout> key <key>

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP

6TANV57CLI-35A

2-1225

Total Access/NetVanta Carrier CLI Dictionary

(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105105

2-1226

6TANV57CLI-35A

Section 2, Commands - Application Configuration Command Set

validate tacacs-server host A.B.C.D username WORD


password
Syntax Description
A.B.C.D

IPAddress

WORD

Username

Usage Examples
ThefollowingisanexampleofhowtousethevalidatetacacsserverhostA.B.C.Dusername
WORDpasswordcommand.
tacacs-server host <ip>
tacacs-server host <ip> key <key>
tacacs-server host <ip> key <key> port <port>
tacacs-server host <ip> key <key> timeout <timeout>
tacacs-server host <ip> key <key> port <port> timeout <timeout>
tacacs-server host <ip> key <key> timeout <timeout> port <port>
tacacs-server host <ip> timeout <timeout>
tacacs-server host <ip> timeout <timeout> key <key>
tacacs-server host <ip> timeout <timeout> key <key> port <port>
tacacs-server host <ip> timeout <timeout> port <port> key <key>
tacacs-server host <ip> port <port>
tacacs-server host <ip> port <port> key <key>
tacacs-server host <ip> port <port> timeout <timeout>
tacacs-server host <ip> port <port> key <key> timeout <timeout>
tacacs-server host <ip> port <port> timeout <timeout> key <key>

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP

6TANV57CLI-35A

2-1227

Total Access/NetVanta Carrier CLI Dictionary

(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105099

2-1228

6TANV57CLI-35A

Section 2, Commands - ATM Group Interface Configuration Command Set

ATM Group Interface Configuration Command Set


UsetheATMGroupInterfaceConfigurationCommandSettoconfiguretheselectedATM
groups.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface atm-group * legacy-atm
ChassisId(config-command)#

ThefollowingisalistofcommandsavailableintheATMGroupInterfaceConfiguration
CommandSet.
exit
link[<slot/port>|<slot/port:chan>]
shutdown

6TANV57CLI-35A

2-1229

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
119700

2-1230

6TANV57CLI-35A

Section 2, Commands - ATM Group Interface Configuration Command Set

link [<slot/port> |<slot/port:chan>]


Functional Notes
Usethelink<shelf/slot/port>or<shelf/slot/port:chan>commandtoanatmlinktoaATM
Group

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
119670

6TANV57CLI-35A

2-1231

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Functional Notes
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
119659

2-1232

6TANV57CLI-35A

Section 2, Commands - ATM Interface Configuration Command Set

ATM Interface Configuration Command Set


UsetheATMInterfaceConfigurationCommandSettoconfiguretheATMinterface.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface atm <shelf/slot/port>
ChassisId(config-atm x/x/x[.sub])#

ThefollowingisalistofcommandsavailableintheATMInterfaceConfigurationCommand
Set.
exit
shutdown
shutdownunassigned

6TANV57CLI-35A

2-1233

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
78810

2-1234

6TANV57CLI-35A

Section 2, Commands - ATM Interface Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-atm 1/9/3)#shutdown
(config-atm 1/9/3)#
! To enable the interface:
(config-atm 1/9/3)#no shutdown
(config-atm 1/9/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
78697

6TANV57CLI-35A

2-1235

Total Access/NetVanta Carrier CLI Dictionary

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisabletheinterface(nodatais
passedthrough).Usethenoshutdowncommandtoenabletheinterfaceandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
(config-atm 1/9/3)#shutdown unassigned
(config-atm 1/9/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
94349

2-1236

6TANV57CLI-35A

Section 2, Commands - Auto Upgrade Configuration Command Set

Auto Upgrade Configuration Command Set


UsetheAutoUpgradecommandsettoconfigureautoupgradesettings.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#auto-upgrade
ChassisId(config-auto-upgrade)#

ThefollowingisalistofcommandsavailableintheAutoUpgradeConfigurationCommand
Set.
alarmenable[complete|failed|softwareversionerror|started|unknownmodule]
alarmenablefile[bad|changed]
alarmlevelsoftwareversionerror[alert|critical|major|minor]
exit
mode[auto|disabled|manual]
refreshinterval<0744>
releaseWORD
retries<010>
scr

6TANV57CLI-35A

2-1237

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [complete|failed|software-versionerror|started|unknown-module]


Usethealarmenable[complete|failed|softwareversionerror|started|unknownmodule]
commandtoenableautoupgradealarms.Usethenoformofthiscommandtodisablethe
alarms.

Syntax Description
complete

Autoupgradeiscomplete

failed

Autoupgradehasfailed

softwareversionerror

Badsoftwareversion

started

Autoupgradehasstarted

unknownmodule

Unknownmoduledetected

Usage Examples
Thefollowingisanexampleofhowtousethealarmenable[complete|failed|software
versionerror|started|unknownmodule]command.
(config-auto-upgrade)#alarm enable complete
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86656

2-1238

6TANV57CLI-35A

Section 2, Commands - Auto Upgrade Configuration Command Set

alarm enable file [bad|changed]


Usethealarmenablefile[bad|changed]commandtoenableautoupgradefilealarms.Usethe
noformofthiscommandtodisablethealarms.

Syntax Description
bad

Fileisbad

changed

Filehaschanged

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablefile[bad|changed]command.
(config-auto-upgrade)#alarm enable file bad
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86659

6TANV57CLI-35A

2-1239

Total Access/NetVanta Carrier CLI Dictionary

alarm level software-version-error [alert|critical|major|minor]


Usethealarmlevelsoftwareversionerror[alert|critical|major|minor]commandtosetthe
alarmseverityleveloftheautoupgradesoftwareversionerroralarm.Usethenoformofthis
commandtosetthealarmseverityleveltothedefaultsetting.

Syntax Description
alert

Alert

critical

Critical

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelsoftwareversionerror
[alert|critical|major|minor]command.
(config-auto-upgrade)#alarm level software-version-error alert
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87237

2-1240

6TANV57CLI-35A

Section 2, Commands - Auto Upgrade Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80689

6TANV57CLI-35A

2-1241

Total Access/NetVanta Carrier CLI Dictionary

mode [auto|disabled|manual]
Usethemode[auto|disabled|manual]commandtoconfiguretheautoupgrademodeof
operation.Usethenoformofthiscommandtodefaulttheautoupgrademodeofoperation.

Syntax Description
auto

Setautoupgrademodetoautomatic

disabled

Setautoupgrademodetodisabled

manual

Setautoupgrademodetomanual

Usage Examples
Thefollowingisanexampleofhowtousethemode[auto|disabled|manual]command.
(config-auto-upgrade)#mode auto
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64004

2-1242

6TANV57CLI-35A

Section 2, Commands - Auto Upgrade Configuration Command Set

refresh-interval <0-744>
Usetherefreshinterval<0744>commandtosettherefreshintervalfortheautoupgrade
configurationfile.Usethenoformofthiscommandtosettheintervaltothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousetherefreshinterval<0744>command.
(config-auto-upgrade)#refresh-interval 744
(config-auto-upgrade)#

Functional Notes
Thevalidrangefortheintervalis0to744hours.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64013

6TANV57CLI-35A

2-1243

Total Access/NetVanta Carrier CLI Dictionary

release WORD
UsethereleaseWORDcommandtoenterthenameforthesystemrelease.Usethenoformof
thiscommandtosetthesystemreleasenametothedefaultvalue.

Usage Examples
ThefollowingisanexampleofhowtousethereleaseWORDcommand.
(config-auto-upgrade)#release SR4.1
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64017

2-1244

6TANV57CLI-35A

Section 2, Commands - Auto Upgrade Configuration Command Set

retries <0-10>
Usetheretries<010>commandtosetthenumberoftimesautoupgraderetriestheupgrade.
Usethenoformofthiscommandtosetthenumberofretriestothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousetheretries<010>command.
(config-auto-upgrade)#retries 10
(config-auto-upgrade)#

Functional Notes
Thevalidrangeforthenumberofretriesis0to10.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64021

6TANV57CLI-35A

2-1245

Total Access/NetVanta Carrier CLI Dictionary

scr
UsethescrcommandtoenableautoupgradetouseSystemControlledReboot(SCR).Usethe
noformofthiscommandtodisabletheuseofSCRwithautoupgrade.

Usage Examples
Thefollowingisanexampleofhowtousethescrcommand.
(config-auto-upgrade)#scr
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83070

2-1246

6TANV57CLI-35A

Section 2, Commands - Counter Profile Configuration Command Set

Counter Profile Configuration Command Set


UsetheCounterProfileConfigurationCommandSettomodifyaprofileforacounterthatcan
beattachedtooneormoredynamiccounters.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#counter-profile <shelf/slot/index>
ChassisId(config-count-prof x/x/x)#

ThefollowingisalistofcommandsavailableintheCounterProfileConfigurationCommand
Set.
color[green|red|yellow]
exit
pbit<07>
vlan[<04094>|none]

6TANV57CLI-35A

2-1247

Total Access/NetVanta Carrier CLI Dictionary

color [green|red|yellow]
Usethecolor[green|red|yellow]commandtoincludecolormarkingintheselectedcounter
profile.Usethenoformofthiscommandtoremovecolormarkingfromtheselectedcounter
profile.

Syntax Description
green

PacketsthatcomplywithCIR/CBS

red

PacketsthatviolateCIR/CBSandEIR/EBS

yellow

PacketsthatviolateCIR/CBSbutcomplywithEIR/EBS

Usage Examples
Thefollowingisanexampleofhowtousethecolor[green|red|yellow]command.
(config-count-prof 1/0/4)#color yellow
(config-count-prof 1/0/4)#

Functional Notes
Colorisnotincludedinthematchingcriteriabydefault.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46018

2-1248

6TANV57CLI-35A

Section 2, Commands - Counter Profile Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usetheexit
commandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46058

6TANV57CLI-35A

2-1249

Total Access/NetVanta Carrier CLI Dictionary

pbit <0-7>
Usethepbit<07>commandtoincludetheVLANpriorityinthecounterprofile.Usetheno
formofthiscommandtoremovetheVLANpriorityfromthecounterprofile.

Usage Examples
Thefollowingisanexampleofhowtousethepbit<07>command.
(config-count-prof 1/0/4)#pbit 3
(config-count-prof 1/0/4)#

Functional Notes
ThevalidrangeforthePbitvalueis07.Bydefault,theVLANpriorityisnotincludedinthe
matchingcriteria.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46017

2-1250

6TANV57CLI-35A

Section 2, Commands - Counter Profile Configuration Command Set

vlan [<0-4094>|none]
Usethevlan[<04094>|none]commandtoincludetheVLANidentifierinthecounterprofile.
UsethenoformofthiscommandtoremovetheVLANidentifierfromthecounterprofile.

Syntax Description
<04094>

VLANID

none

Includeuntaggedtrafficinmatchingcriteria

Usage Examples
Thefollowingisanexampleofhowtousethevlan[<04094>|none]command.
(config-count-prof 1/0/4)#vlan 100
(config-count-prof 1/0/4)#

Functional Notes
VLANidentifiersarenotincludedinthematchingcriteriabydefault.Thevalidrangefor
VLANidentifiersis04094.VLANidentifiersarenotincludedinthematchingcriteriaby
default.
Usethenoneoptiontoonlyincludeuntaggedtrafficinthematchingcriteria.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46014

6TANV57CLI-35A

2-1251

Total Access/NetVanta Carrier CLI Dictionary

Dynamic Counters Configuration Command Set


UsetheDynamicsCounterConfigurationCommandSettoconfigureadynamiccounter.
Dynamiccountersarealimitednumberofperflowcountersthatcanbeusedfordebugging.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#dynamic-counter <shelf/slot/index>
ChassisId(config-dyn-count x/x/x)#

ThefollowingisalistofcommandsavailableintheDynamicCountersConfiguration
CommandSet.
exit
setcounterprofile<shelf/slot/index>[exclude|include]
setinterfacebackplane<shelf/slot/port>[rx|tx]
setinterfacebackplane<shelf/slot/port>queue<0n>[congestiondrop|dequeue|enqueue]
setinterfaceefmgroup<shelf/slot/port>[rx|tx]
setinterfaceefmgroup<shelf/slot/port>queue<0n>[congestion
drop|dequeue|enqueue]
setinterfaceethernet<shelf/slot/port>[rx|tx]
setinterfaceethernet<shelf/slot/port>queue<0n>[congestiondrop|dequeue|enqueue]
setinterfacegigabitethernet<shelf/slot/port>[rx|tx]
setinterfacegigabitethernet<shelf/slot/port>queue<0n>[congestion
drop|dequeue|enqueue]
setinterfacelaggroup<shelf/slot/group>[rx|tx]
setinterfacemuxponderhighspeed<shelf/slot/port>[rx|tx]
setinterfacemuxpondermidspeed<shelf/slot/port>[rx|tx]
setinterfaceprocessorethernet[rx|tx]
setinterfaceprocessorethernetqueue<0n>[congestiondrop|dequeue|enqueue]
setinterfacetengigabitethernet<shelf/slot/port>[rx|tx]
shutdown

2-1252

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usetheexit
commandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46010

6TANV57CLI-35A

2-1253

Total Access/NetVanta Carrier CLI Dictionary

set counter-profile <shelf/slot/index> [exclude|include]


Usethesetcounterprofile<shelf/slot/index>[exclude|include]commandtoaddaspecific
counterprofiletothedynamiccounter.Usethenoformofthiscommandtoremovethe
counterprofilefromthedynamiccounter.

Syntax Description
exclude

Countpackets/bytesthatdonotmatchtheprofile

include

Countpackets/bytesthatmatchtheprofile

Usage Examples
Thefollowingisanexampleofhowtousethesetcounterprofile<shelf/slot/index>
[exclude|include]command.
(config-dyn-count 1/0/2)#set counter-profile 1/0/3 include
(config-dyn-count 1/0/2)#

Functional Notes
Adynamiccounterworkswithoutattachingacounterprofile.Acounterprofileprovides
additionalfilteringcapabilities.Onlyonecounterprofilemaybeattachedtoeachdynamic
counter,however,asinglecounterprofilemaybeattachedtomorethanonedynamiccounter.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
61848

2-1254

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface backplane <shelf/slot/port> [rx|tx]


Usethesetinterfacebackplane<shelf/slot/port>[rx|tx]commandtoaddabackplaneinterface
tothedynamiccounter.Usethenoformofthiscommandtoremovethedynamiccounter
fromtheinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacebackplane<shelf/slot/port>[rx|tx]
command.
(config-dyn-count 1/0/1)#set interface backplane 1/0/2 rx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65156

6TANV57CLI-35A

2-1255

Total Access/NetVanta Carrier CLI Dictionary

set interface backplane <shelf/slot/port> queue <0-n>


[congestion-drop|dequeue|enqueue]
Usethesetinterfacebackplane<shelf/slot/port>queue<0n>[congestion
drop|dequeue|enqueue]commandtocollectqueuestatisticsonthebackplaneinterface.Use
thenoformofthiscommandtoremovethedynamiccounterfromtheinterface.

Syntax Description
<shelf/slot/port>

EnterBackplaneinterface

congestiondrop

Frameschosenbythecongestionmanagertobedroppedrather
thanenqueued

dequeue

Framesremovedfromthequeuebytheschedulertobesenton
theinterface

enqueue

Frameschosenbythecongestionmanagertobeenqueued

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacebackplane<shelf/slot/port>queue
<0n>[congestiondrop|dequeue|enqueue]command.
(config-dyn-count 1/0/1)#set interface backplane 1/0/3 queue 1
congestion-drop
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65237

2-1256

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface efm-group <shelf/slot/port> [rx|tx]


Usethesetinterfaceefmgroup<shelf/slot/port>[rx|tx]commandtoaddanEFMgroup
interfacetothedynamiccounter.Usethenoformofthiscommandtoremovethedynamic
counterfromtheinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceefmgroup<shelf/slot/port>[rx|tx]
command.
(config-dyn-count 1/0/1)#set interface efm-group 1/0/2 rx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65201

6TANV57CLI-35A

2-1257

Total Access/NetVanta Carrier CLI Dictionary

set interface efm-group <shelf/slot/port> queue <0-n>


[congestion-drop|dequeue|enqueue]
UsethesetinterfaceefmgroupqueuecommandtocollectqueuestatisticsonanEFMgroup
interface.Usethenoformofthecommandtoremovethedynamiccounterfromtheinterface.

Syntax Description
<shelf/slot/port>

Specifiedgroup

congestiondrop

Frameschosenbythecongestionmanagertobedroppedrather
thanenqueued

dequeue

Framesremovedfromthequeuebytheschedulertobesenton
theinterface

enqueue

Frameschosenbythecongestionmanagertobeenqueued

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceefmgroup<shelf/slot/port>queue
<0n>[congestiondrop|dequeue|enqueue]command.
(config-dyn-count 1/0/1)#set interface efm-group 1/0/3 queue 1
congestion-drop
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface efm-group 1/0/3 queue 2 dequeue
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface efm-group 1/0/4 queue 7 enqueue
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828

2-1258

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65205

6TANV57CLI-35A

2-1259

Total Access/NetVanta Carrier CLI Dictionary

set interface ethernet <shelf/slot/port> [rx|tx]


UsethesetinterfaceethernetcommandtoaddanEthernetinterfacetothedynamiccounter.
Usethenoformofthecommandtoremovethedynamiccounterfromtheinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceethernet<shelf/slot/port>[rx|tx]
command.
(config-dyn-count 1/0/1)#set interface ethernet 1/0/2 rx
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface ethernet 1/0/2 tx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65184

2-1260

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface ethernet <shelf/slot/port> queue <0-n>


[congestion-drop|dequeue|enqueue]
UsethesetinterfaceethernetqueuecommandtocollectqueuestatisticsonanEthernet
interface.Usethenoformofthecommandtoremovethedynamiccounterfromtheinterface.

Syntax Description
<shelf/slot/port>

Ethernetinterface

congestiondrop

Frameschosenbythecongestionmanagertobedroppedrather
thanenqueued

dequeue

Framesremovedfromthequeuebytheschedulertobesenton
theinterface

enqueue

Frameschosenbythecongestionmanagertobeenqueued

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceethernet<shelf/slot/port>queue
<0n>[congestiondrop|dequeue|enqueue]command.
(config-dyn-count 1/0/1)#set interface ethernet 1/0/3 queue 1 congestiondrop
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface ethernet 1/0/3 queue 2 dequeue
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface ethernet 1/0/4 queue 7 enqueue
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

6TANV57CLI-35A

2-1261

Total Access/NetVanta Carrier CLI Dictionary

Command ID
65089

2-1262

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface gigabit-ethernet <shelf/slot/port> [rx|tx]


UsethesetinterfacegigabitethernetcommandtoaddaGigabitEthernetinterfacetothe
dynamiccounter.Usethenoformofthecommandtoremovethedynamiccounterfromthe
interface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacegigabitethernet<shelf/slot/port>
[rx|tx]command.
(config-dyn-count 1/0/1)#set interface gigabit-ethernet 1/0/2 rx
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface gigabit-ethernet 1/0/2 tx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550G2),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
65095

6TANV57CLI-35A

2-1263

Total Access/NetVanta Carrier CLI Dictionary

set interface gigabit-ethernet <shelf/slot/port> queue <0-n>


[congestion-drop|dequeue|enqueue]
UsethesetinterfacegigabitethernetqueuecommandtocollectqueuestatisticsonaGigabit
Ethernetinterface.Usethenoformofthecommandtoremovethedynamiccounterfromthe
interface.

Syntax Description
<shelf/slot/port>

GigabitEthernetinterface

congestiondrop

Packetschosenbythecongestionmanagertobedropped

dequeue

Framesremovedfromthequeuebytheschedulertobesenton
theinterface

enqueue

Frameschosenbythecongestionmanagertobeenqueued

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacegigabitethernet<shelf/slot/port>
queue<0n>[congestiondrop|dequeue|enqueue]command.
(config-dyn-count 1/0/1)#set interface gigabit-ethernet 1/0/3 queue 1
congestion-drop
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface gigabit-ethernet 1/0/3 queue 2
dequeue
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface gigabit-ethernet 1/0/4 queue 7
enqueue
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T

2-1264

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65188

6TANV57CLI-35A

2-1265

Total Access/NetVanta Carrier CLI Dictionary

set interface lag-group <shelf/slot/group> [rx|tx]


Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1)

Command ID
83131

2-1266

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface muxponder-highspeed <shelf/slot/port> [rx|tx]


UsethesetinterfacemuxponderhighspeedcommandtoaddaMuxponderHighspeed
interfacetothedynamiccounter.Usethenoformofthecommandtoremovethedynamic
counterfromtheinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacemuxponderhighspeed<shelf/slot/
port>[rx|tx]command.
(config-dyn-count 1/0/1)#set interface muxponder-highspeed 1/0/2 rx
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface muxponder-highspeed 1/0/2 tx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145935

6TANV57CLI-35A

2-1267

Total Access/NetVanta Carrier CLI Dictionary

set interface muxponder-midspeed <shelf/slot/port> [rx|tx]


UsethesetinterfacemuxpondermidspeedcommandtoaddaMuxponderMidspeed
interfacetothedynamiccounter.Usethenoformofthecommandtoremovethedynamic
counterfromtheinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfacemuxpondermidspeed<shelf/slot/
port>[rx|tx]command.
(config-dyn-count 1/0/1)#set interface muxponder-midspeed 1/0/2 rx
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface muxponder-midspeed 1/0/2 tx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145926

2-1268

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

set interface processor-ethernet [rx|tx]


UsethesetinterfaceprocessorethernetcommandtoaddtheprocessorEthernetinterfaceto
thedynamiccounter.Usethenoformofthecommandtoremovethedynamiccounterfrom
theinterface.

Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceprocessorethernet[rx|tx]
command.
(config-dyn-count 1/0/1)#set interface processor-ethernet rx
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface processor-ethernet tx
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65166

6TANV57CLI-35A

2-1269

Total Access/NetVanta Carrier CLI Dictionary

set interface processor-ethernet queue <0-n> [congestiondrop|dequeue|enqueue]


Usethesetinterfaceprocessorethernetqueuecommandtocollectqueuestatisticsonthe
processorEthernetinterface.Usethenoformofthecommandtoremovethedynamiccounter
fromtheinterface.

Syntax Description
congestiondrop

Frameschosenbythecongestionmanagertobedroppedrather
thanenqueued

dequeue

Framesremovedfromthequeuebytheschedulertobesenton
theinterface

enqueue

Frameschosenbythecongestionmanagertobeenqueued

Usage Examples
Thefollowingisanexampleofhowtousethesetinterfaceprocessorethernetqueue<0n>
[congestiondrop|dequeue|enqueue]command.
(config-dyn-count 1/0/1)#set interface processor-ethernet queue 1
congestion-drop
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface processor-ethernet queue 2 dequeue
(config-dyn-count 1/0/1)#
(config-dyn-count 1/0/1)#set interface processor-ethernet queue 7 enqueue
(config-dyn-count 1/0/1)#

Functional Notes
Adynamiccountermustbeappliedtoaninterfacebeforeattemptingtocount.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814

2-1270

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
65172

6TANV57CLI-35A

2-1271

Total Access/NetVanta Carrier CLI Dictionary

set interface ten-gigabit-ethernet <shelf/slot/port> [rx|tx]


Syntax Description
rx

Framesreceivedbythisinterface

tx

Framestransmittedbythisinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65218

2-1272

6TANV57CLI-35A

Section 2, Commands - Dynamic Counters Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisablethedynamiccounter.Usetheno
formofthiscommandtoenablethedynamiccounter.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the dynamic counter:
(config-dyn-count 1/0/1)#shutdown
(config-dyn-count 1/0/1)#
! To enable the dynamic counter:
(config-dyn-count 1/0/1)#no shutdown
(config-dyn-count 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46060

6TANV57CLI-35A

2-1273

Total Access/NetVanta Carrier CLI Dictionary

E1 Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface e1 <shelf/slot/port>
ChassisId(config-e1 x/x/x)#

ThefollowingisalistofcommandsavailableintheE1InterfaceConfigurationCommandSet.
alarmenableshutdownmaintenance
autoinserviceenable
autoinservicetimeout<19999>
clocksource[internal|line]
coding[ami|hdb3]
descriptionLINE
exit
framing[cas|cascrc|ccs|ccscrc|unframed]
remotealarm[ebit|rai]
shutdown[maintenance|unassigned]
thresholdscvl15minute<04294967295>
thresholdscvl24hour<04294967295>
thresholdscvp15minute<04294967295>
thresholdscvp24hour<04294967295>
thresholdsesl15minute<0900>
thresholdsesl24hour<086400>
thresholdsesp15minute<0900>
thresholdsesp24hour<086400>
thresholdssesp15minute<0900>
thresholdssesp24hour<086400>
thresholdsuasp15minute<0900>
thresholdsuasp24hour<086400>
timeoutloopback<09999>

2-1274

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2)

Command ID
111854

6TANV57CLI-35A

2-1275

Total Access/NetVanta Carrier CLI Dictionary

auto-in-service enable
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2)

Command ID
111681

2-1276

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

auto-in-service timeout <1-9999>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2)

Command ID
111683

6TANV57CLI-35A

2-1277

Total Access/NetVanta Carrier CLI Dictionary

clock source [internal|line]


Syntax Description
internal

Timingderivedfromlocalclock

line

Timingderivedfromreceiveinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
67290

2-1278

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

coding [ami|hdb3]
Syntax Description
ami

AlternateMarkInversion

hdb3

HighDensityBipolarofOrder3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),
NV814(1200637G4),NV818(1200637G2)

Command ID
45628

6TANV57CLI-35A

2-1279

Total Access/NetVanta Carrier CLI Dictionary

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedE1interface.Theidentificationis
customercontrolledandmaintainedasaconfigurationitemfortheselectedE1interface.Use
thenoformofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-e1 1/0/1)#description E1 Port 1
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
78725

2-1280

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
78803

6TANV57CLI-35A

2-1281

Total Access/NetVanta Carrier CLI Dictionary

framing [cas|cas-crc|ccs|ccs-crc|unframed]
Syntax Description
cas

SetframingtoTS16multiframe

cascrc

SetframingtoCAS+CRC

ccs

SetframingtoFAS

ccscrc

SetframingtoFAS+CRC

unframed

Setframingtounframed

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
45632

2-1282

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

remote-alarm [ebit|rai]
UsetheremotealarmcommandtoenablethetransmissionofEBitorRAIremotealarmson
theE1interface.Usethenoformofthiscommandtoreturntothedefaultsetting.

Syntax Description
ebit

EnabletransmissionofEBit

rai

EnabletransmissionofRAI

Usage Examples
Thefollowingisanexampleofhowtousetheremotealarm[ebit|rai]command.
(config-e1 1/0/1)#remote-alarm ebit
(config-e1 1/0/1)#
(config-e1 1/0/1)#no remote-alarm rai
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
45642

6TANV57CLI-35A

2-1283

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.Use
theshutdownmaintenancecommandtoenabletheinterfacebutinhibitalarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-e1 1/0/1)#shutdown
(config-e1 1/0/1)#
! To disable the interface:
(config-e1 1/0/1)#shutdown unassigned
(config-e1 1/0/1)#
! To enable the interface:
(config-e1 1/0/1)#no shutdown
(config-e1 1/0/1)#
! To enable the interface but inhibit alarms:
(config-e1 1/0/1)#shutdown maintenance
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

2-1284

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

Command ID
78696

6TANV57CLI-35A

2-1285

Total Access/NetVanta Carrier CLI Dictionary

thresholds cv-l 15-minute <0-4294967295>


Usethethresholdscvl15minutecommandtoconfigurethe15minuteCodeViolationsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl15minute<04294967295>
command.
(config-e1 1/0/1)#thresholds cv-l 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77309

2-1286

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds cv-l 24-hour <0-4294967295>


Usethethresholdscvl24hourcommandtoconfigurethe24hourCodeViolationsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl24hour<04294967295>
command.
(config-e1 1/0/1)#thresholds cv-l 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77311

6TANV57CLI-35A

2-1287

Total Access/NetVanta Carrier CLI Dictionary

thresholds cv-p 15-minute <0-4294967295>


Usethethresholdscvp15minutecommandtoconfigurethe15minuteCodeViolationsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvp15minute<04294967295>
command.
(config-e1 1/0/1)#thresholds cv-p 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77289

2-1288

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds cv-p 24-hour <0-4294967295>


Usethethresholdscvp24hourcommandtoconfigurethe24hourCodeViolationsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvp24hour<04294967295>
command.
(config-e1 1/0/1)#thresholds cv-p 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77291

6TANV57CLI-35A

2-1289

Total Access/NetVanta Carrier CLI Dictionary

thresholds es-l 15-minute <0-900>


Usethethresholdsesl15minutecommandtoconfigurethe15minuteErroredSecondsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl15minute<0900>command.
(config-e1 1/0/1)#thresholds es-l 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77304

2-1290

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds es-l 24-hour <0-86400>


Usethethresholdsesl24hourcommandtoconfigurethe24hourErroredSecondsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl24hour<086400>command.
(config-e1 1/0/1)#thresholds es-l 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77306

6TANV57CLI-35A

2-1291

Total Access/NetVanta Carrier CLI Dictionary

thresholds es-p 15-minute <0-900>


Usethethresholdsesp15minutecommandtoconfigurethe15minuteErroredSecondsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesp15minute<0900>command.
(config-e1 1/0/1)#thresholds es-p 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77284

2-1292

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds es-p 24-hour <0-86400>


Usethethresholdsesp24hourcommandtoconfigurethe24hourErroredSecondsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesp24hour<086400>command.
(config-e1 1/0/1)#thresholds es-p 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77286

6TANV57CLI-35A

2-1293

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses-p 15-minute <0-900>


Usethethresholdssesp15minutecommandtoconfigurethe15minuteSeverelyErrored
SecondsPathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturn
thethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesp15minute<0900>command.
(config-e1 1/0/1)#thresholds ses-p 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77294

2-1294

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds ses-p 24-hour <0-86400>


Usethethresholdssesp24hourcommandtoconfigurethe24hourSeverelyErroredSeconds
Pathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturnthe
thresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesp24hour<086400>command.
(config-e1 1/0/1)#thresholds ses-p 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77296

6TANV57CLI-35A

2-1295

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas-p 15-minute <0-900>


Usethethresholdsuasp15minutecommandtoconfigurethe15minuteUnavailable
SecondsPathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturn
thethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp15minute<0900>command.
(config-e1 1/0/1)#thresholds uas-p 15-minute 20
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77299

2-1296

6TANV57CLI-35A

Section 2, Commands - E1 Interface Configuration Command Set

thresholds uas-p 24-hour <0-86400>


Usethethresholdsuasp24hourcommandtoconfigurethe24hourUnavailableSeconds
Pathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturnthe
thresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp24hour<086400>command.
(config-e1 1/0/1)#thresholds uas-p 24-hour 100
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
77301

6TANV57CLI-35A

2-1297

Total Access/NetVanta Carrier CLI Dictionary

timeout loopback <0-9999>


Usethetimeoutcommandtoconfigureatimeoutusedtoautomaticallyremoveanyactive
loopbackortestpatternontheE1interface.Usethenoformofthiscommandtoreturnthe
timeouttoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethetimeoutloopback<09999>command.
(config-e1 1/0/1)#timeout loopback 10
(config-e1 1/0/1)#
(config-e1 1/0/1)#timeout test-pattern 10
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
67282

2-1298

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

EFM Group Interface Configuration Command Set


UsetheEFMGroupInterfaceConfigurationCommandSettomodifyconfigurationforan
aggregationofEFMbondedlinks.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface efm-group <shelf/slot/group>
ChassisId(config-efm-group name)#

ThefollowingisalistofcommandsavailableintheEFMGroupInterfaceConfiguration
CommandSet.
activelinksminimum<1n>
aliasWORD
descriptionLINE
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORD[down|up]
ethernetoamenable
exit
link[<slot/port>|<slot/port:chan>]
loopback[detection|remote]
loopbacktimeout<060>
ratecontrol
ratecontrolupstream<0250000>downstream<0250000>
shutdown
shutdownunassigned
stagdei
subtendedhostezprovisioning
subtendedhostipaddressA.B.C.DA.B.C.D
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|listener|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD
subtendedhostsnmpservercommunityreadwriteWORD
subtendedhostsnmpserverezprovisioninghostA.B.C.Dtrapsversion[1|2c]
subtendedhostsnmpserverlocationWORD
subtendedhoststag<14094>
subtendedhoststagpriority<07>
thresholdsbadfragments15minute<04294967295>
thresholdsbadfragments24hour<04294967295>

6TANV57CLI-35A

2-1299

Total Access/NetVanta Carrier CLI Dictionary

thresholdslostends15minute<04294967295>
thresholdslostends24hour<04294967295>
thresholdslostfragments15minute<04294967295>
thresholdslostfragments24hour<04294967295>
thresholdsloststarts15minute<04294967295>
thresholdsloststarts24hour<04294967295>
thresholdsxcv[1e5|1e6|1e7]
xcvlinkremoval

2-1300

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

active-links-minimum <1-n>
ThiscommandsetstheminimumnumberofactivelinksforanEFMGroup.Ifratecontrolis
enabledthenthebridgerateisdividedbythisnumbertocalculatetherateofeachoneofthe
EFMLinksformultiratetechnologiessuchasSHDSL.Forexample,ifthedownstreamrate
hasbeensetto12000Kbpsandtheactivelinksminimumhasbeensetto6theneachlinkin
theEFMgroupwillbesetto2000Kbps.Theactivelinksminimumvalueisalsousedto
determinethestatusofanEFMGroup:Up,Down,andPartial.Usethenoformofthis
commandtosettothedefaultvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45049

6TANV57CLI-35A

2-1301

Total Access/NetVanta Carrier CLI Dictionary

alias WORD
ThiscommandisusedtosettheEFMGroupsalias.

Usage Examples
ThefollowingisanexampleofhowtousethealiasWORDcommand.
(config-efm-group 1/18/1)#alias "CIRCUIT ID 23-908"

Functional Notes
Thecharacterstringmustbeenclosedwithquotesifitcontainsspaces.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
64215

2-1302

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedEFMgroupinterface.Usetheno
formofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-efm-group 1/0/1)#description EFM Group #1
(config-efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
78733

6TANV57CLI-35A

2-1303

Total Access/NetVanta Carrier CLI Dictionary

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
64520

2-1304

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

ethernet cfm enable


UsetheethernetcfmenablecommandtoenabletheethernetOAMconnectivityfault
managementsubsystemandallocateresources.Usethenoformofthiscommandtodisable
thesubsystem,causingallCFMfunctionstoceaseanddeallocateresources.Anyexisting
CFMconfigurationisretained,butnoframesaresentorreceivedandnoresourcesare
consumedotherthanspaceintheconfiguration.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmenablecommand.
! To enable the ethernet OAM connectivity fault management subsystem:
(config-efm-group 1/0/1)#ethernet cfm
(config-efm-group 1/0/1)#
! To disable the ethernet OAM connectivity fault management subsystem:
(config-efm-group 1/0/1)#no ethernet cfm
(config-efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
120313

6TANV57CLI-35A

2-1305

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm mep <1-8191> WORD WORD [down|up]


Syntax Description
<18191>

MEPidentifier

WORD

MaintenancedomaintowhichMEPbelongs

down

Facingthephysicalport

up

Facingtheswitchingelement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
51590

2-1306

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
120336

6TANV57CLI-35A

2-1307

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
78807

2-1308

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

link [<slot/port>|<slot/port:chan>]
Usethelink<slot/port>commandtoaddthespecifiedlinkstotheselectedEFMgroup.Use
thenoformofthiscommandtoremovelinks.

Usage Examples
Thefollowingisanexampleofhowtousethelink[<slot/port>|<slot/port:chan>]command.
(config-efm-group 1/0/1)#link 0/1,0/3,0/5,0/7
(config-efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45051

6TANV57CLI-35A

2-1309

Total Access/NetVanta Carrier CLI Dictionary

loopback [detection|remote]
Syntax Description
detection

EnabledetectionofloopbacksonEFMLinks

remote

SendacommandtotheremotedevicetoinitiateanEFM
loopback

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45038

2-1310

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

loopback timeout <0-60>


ThiscommandisusedtosetthenumberofminutesforanEFMGrouploopbacktobeactive
beforeitisautomaticallydisabled.Ifthisvalueissetto0thentheloopbackwillhavetobe
disabledmanually.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
45041

6TANV57CLI-35A

2-1311

Total Access/NetVanta Carrier CLI Dictionary

rate-control
Thiscommandisusedtoenabletheratecontrolfeature.Ratecontrolusestheupstream/
downstreamEFMGroupratesandactivelinksminimumtocalculatetherateforeachEFM
Link.Eachlinkwillbesettotheproductofthefollowingcalculation:EFMLinkdownstream
rate=EFMGroupdownstreamrate/activelinksminimumEFMLinkupstreamrate=EFM
Groupupstreamrate/activelinksminimumUsethenoformofthiscommandtodisable
ratecontrol.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45042

2-1312

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

rate-control upstream <0-250000> downstream <0-250000>


ThiscommandisusedtosettheupstreamanddownstreamratesfortheEFMGroup.

Syntax Description
<0250000>

Rateinkbps

Usage Examples
Thefollowingisanexampleofhowtousetheratecontrolupstream<0250000>downstream
<0250000>command.
(config-efm-group 1/18/1)#rate-control upstream 12000 downstream 12000

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
45047

6TANV57CLI-35A

2-1313

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-efm-group 1/18/1)#shutdown
(config-efm-group 1/18/1)#
! To enable the interface:
(config-efm-group 1/18/1)#no shutdown
(config-efm-group 1/18/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
78686

2-1314

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisabletheinterface(nodatais
passedthrough).Usethenoshutdowncommandtoenabletheinterfaceandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
(config-efm-group 1/18/1)#shutdown unassigned
(config-efm-group 1/18/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
94343

6TANV57CLI-35A

2-1315

Total Access/NetVanta Carrier CLI Dictionary

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
96567

2-1316

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host ez-provisioning
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV814(1200637G4),NV
818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
138277

6TANV57CLI-35A

2-1317

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip address A.B.C.D A.B.C.D


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipaddressA.B.C.DA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip address 192.168.0.2
255.255.255.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
66008

2-1318

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipdefaultgatewayA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip default-gateway 192.168.0.254

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45022

6TANV57CLI-35A

2-1319

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Usage Examples
Thefollowingisanexampleofhowtousethesubtendedhostipfileserverdefaulthost
A.B.C.Dcommand.
(config-efm-group 1/18/1)#subtended-host ip file-server default host
192.168.0.1

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45024

2-1320

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host mode [disabled|listener|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

listener

Acceptssubtendedhostparametersfromconnecteddevice

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
97346

6TANV57CLI-35A

2-1321

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
66000

2-1322

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65998

6TANV57CLI-35A

2-1323

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65997

2-1324

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host snmp-server ez-provisioning host A.B.C.D


traps version [1|2c]
Syntax Description
A.B.C.D

IPaddress

Version1

2c

Version2c

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV814(1200637G4),NV
818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
138267

6TANV57CLI-35A

2-1325

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server location WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV814(1200637G4),NV
818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
138276

2-1326

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

subtended-host s-tag <1-4094>


ThiscommandisusedtosettheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45026

6TANV57CLI-35A

2-1327

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
45028

2-1328

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

thresholds bad-fragments 15-minute <0-4294967295>


Usethethresholdsbadfragments15minute<04294967295>commandtoconfigurethealarm
thresholdforbadfragmentsreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbadfragments15minute<0
4294967295>command.
(config-efm-group 1/0/1)#thresholds bad-fragments 15-minute 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44978

6TANV57CLI-35A

2-1329

Total Access/NetVanta Carrier CLI Dictionary

thresholds bad-fragments 24-hour <0-4294967295>


Usethethresholdsbadfragments24hour<04294967295>commandtoconfigurethealarm
thresholdforbadfragmentsreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbadfragments24hour<0
4294967295>command.
(config-efm-group 1/0/1)#thresholds bad-fragments 24-hour 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44974

2-1330

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

thresholds lost-ends 15-minute <0-4294967295>


Usethethresholdslostends15minute<04294967295>commandtoconfigurethealarm
thresholdforlostendsreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslostends15minute<04294967295>
command.
(config-efm-group 1/0/1)#thresholds lost-ends 15-minute 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44988

6TANV57CLI-35A

2-1331

Total Access/NetVanta Carrier CLI Dictionary

thresholds lost-ends 24-hour <0-4294967295>


Usethethresholdsbadfragments24hour<04294967295>commandtoconfigurethealarm
thresholdforbadfragmentsreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslostends24hour<04294967295>
command.
(config-efm-group 1/0/1)#thresholds lost-ends 24-hour 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44984

2-1332

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

thresholds lost-fragments 15-minute <0-4294967295>


Usethethresholdslostends15minute<04294967295>commandtoconfigurethealarm
thresholdforlostendsreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslostfragments15minute<0
4294967295>command.
(config-efm-group 1/0/1)#thresholds lost-fragments 15-minute 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44998

6TANV57CLI-35A

2-1333

Total Access/NetVanta Carrier CLI Dictionary

thresholds lost-fragments 24-hour <0-4294967295>


Usethethresholdsbadfragments24hour<04294967295>commandtoconfigurethealarm
thresholdforbadfragmentsreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslostfragments24hour<0
4294967295>command.
(config-efm-group 1/0/1)#thresholds lost-fragments 24-hour 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44994

2-1334

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

thresholds lost-starts 15-minute <0-4294967295>


Usethethresholdsloststarts15minute<04294967295>commandtoconfigurethealarm
thresholdforloststartsreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsloststarts15minute<04294967295>
command.
(config-efm-group 1/0/1)#thresholds lost-starts 15-minute 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45008

6TANV57CLI-35A

2-1335

Total Access/NetVanta Carrier CLI Dictionary

thresholds lost-starts 24-hour <0-4294967295>


Usethethresholdsloststarts24hour<04294967295>commandtoconfigurethealarm
thresholdforloststartsreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsloststarts24hour<04294967295>
command.
(config-efm-group 1/0/1)#thresholds lost-starts 24-hour 2000
(config-efm-group 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45004

2-1336

6TANV57CLI-35A

Section 2, Commands - EFM Group Interface Configuration Command Set

thresholds xcv [1e-5|1e-6|1e-7]


Usethethresholdsxcv[1e5|1e6|1e7]commandtoconfigurethethresholdatwhichalink
willautomaticallyberemovedfromtheEFMgroupifXCVlinkremovalisenabled.

Syntax Description
1e5

Biterrorrateof1e5

1e6

Biterrorrateof1e6

1e7

Biterrorrateof1e7

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsxcv[1e5|1e6|1e7]command.
(config-efm-group 1/0/1)#thresholds xcv 1e-6
(config-efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45010

6TANV57CLI-35A

2-1337

Total Access/NetVanta Carrier CLI Dictionary

xcv-link-removal
UsethexcvlinkremovalcommandtoenabletheautomaticremovalofanEFMlinkthat
crossestheconfiguredXCVthreshold.Usethenoformofthiscommandtodisablethe
removal.

Usage Examples
Thefollowingisanexampleofhowtousethexcvlinkremovalcommand.
(config-efm-group 1/0/1)#no xcv-link-removal
(config-efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45014

2-1338

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

EFM Link Interface Configuration Command Set


UsetheEFMLinkInterfaceConfigurationCommandSettoconfigureanindividualEFM
fragmented64/65octetencodedEtherenetlink.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface efm-link <shelf/slot/port>
ChassisId(config-efm-link name)#

ThefollowingisalistofcommandsavailableintheEFMLinkInterfaceConfiguration
CommandSet.
descriptionLINE
exit
thresholdscodingerrors15minute<04294967295>
thresholdscodingerrors24hour<04294967295>
thresholdsdiscardedfragments15minute<04294967295>
thresholdsdiscardedfragments24hour<04294967295>
thresholdserroredfragments15minute<04294967295>
thresholdserroredfragments24hour<04294967295>
thresholdsfcserrors15minute<04294967295>
thresholdsfcserrors24hour<04294967295>
thresholdslargefragments15minute<04294967295>
thresholdslargefragments24hour<04294967295>
thresholdssmallfragments15minute<04294967295>
thresholdssmallfragments24hour<04294967295>

6TANV57CLI-35A

2-1339

Total Access/NetVanta Carrier CLI Dictionary

description LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
105116

2-1340

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
78808

6TANV57CLI-35A

2-1341

Total Access/NetVanta Carrier CLI Dictionary

thresholds coding-errors 15-minute <0-4294967295>


Usethethresholdscodingerrors15minute<04294967295>commandtoconfigurethe15
minutecodingerrorsperformancemonitoringthreshold.Usethenoformofthiscommandto
returnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscodingerrors15minute<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds coding-errors 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
Codingerrorsaredefinedaserrorsinthe64/65octetencoding.Thevalidrangeforthe
thresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45071

2-1342

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds coding-errors 24-hour <0-4294967295>


Usethethresholdscodingerrors24hour<04294967295>commandtoconfigurethe24hour
codingerrorsperformancemonitoringthreshold.Usethenoformofthiscommandtoreturn
thethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscodingerrors24hour<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds coding-errors 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
Codingerrorsaredefinedaserrorsinthe64/65octetencoding.Thevalidrangeforthe
thresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45067

6TANV57CLI-35A

2-1343

Total Access/NetVanta Carrier CLI Dictionary

thresholds discarded-fragments 15-minute <0-4294967295>


Usethethresholdsdiscardedfragments15minute<04294967295>commandtoconfigurethe
15minutediscardedfragmentsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscardedfragments15minute<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds discarded-fragments 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
Discardedfragmentsaredefinedtobethesummationoferrored,small,andlargefragments.
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45081

2-1344

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds discarded-fragments 24-hour <0-4294967295>


Usethethresholdsdiscardedfragments24hour<04294967295>commandtoconfigurethe
24hourdiscardedfragmentsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscardedfragments24hour<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds discarded-fragments 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
Discardedfragmentsaredefinedtobethesummationoferrored,small,andlargefragments.
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45077

6TANV57CLI-35A

2-1345

Total Access/NetVanta Carrier CLI Dictionary

thresholds errored-fragments 15-minute <0-4294967295>


Usethethresholdserroredfragments15minute<04294967295>commandtoconfigurethe
15minuteerroredfragmentsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserroredfragments15minute<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds errored-fragments 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
Erroredfragmentsaredefinedtobefragmentsthatcontainoneormorechecksumorcoding
errors.Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45091

2-1346

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds errored-fragments 24-hour <0-4294967295>


Usethethresholdserroredfragments24hour<04294967295>commandtoconfigurethe24
hourerroredfragmentsperformancemonitoringthreshold.Usethenoformofthiscommand
toreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserroredfragments24hour<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds errored-fragments 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
Erroredfragmentsaredefinedtobefragmentsthatcontainoneormorechecksumorcoding
errors.Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45087

6TANV57CLI-35A

2-1347

Total Access/NetVanta Carrier CLI Dictionary

thresholds fcs-errors 15-minute <0-4294967295>


Usethethresholdsfcserrors15minute<04294967295>commandtoconfigurethe15minute
fragmentchecksumerrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsfcserrors15minute<04294967295>
command.
(config-efm-link 1/0/1)#thresholds fcs-errors 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
FCSerrorsaredefinedtobefragmentchecksumerrors.Thevalidrangeforthethresholdis0
4294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45101

2-1348

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds fcs-errors 24-hour <0-4294967295>


Usethethresholdsfcserrors24hour<04294967295>commandtoconfigurethe24hour
fragmentchecksumerrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsfcserrors24hour<04294967295>
command.
(config-efm-link 1/0/1)#thresholds fcs-errors 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
FCSerrorsaredefinedtobefragmentchecksumerrors.Thevalidrangeforthethresholdis0
4294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45097

6TANV57CLI-35A

2-1349

Total Access/NetVanta Carrier CLI Dictionary

thresholds large-fragments 15-minute <0-4294967295>


Usethethresholdslargefragments15minute<04294967295>commandtoconfigurethe15
minutelargefragmenterrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslargefragments15minute<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds large-fragments 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
Largefragmentsaredefinedtobefragmentsthatarelargerthan512bytes.Thevalidrangefor
thethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45111

2-1350

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds large-fragments 24-hour <0-4294967295>


Usethethresholdslargefragments24hour<04294967295>commandtoconfigurethe24
hourlargefragmenterrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslargefragments24hour<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds large-fragments 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
Largefragmentsaredefinedtobefragmentsthatarelargerthan512bytes.Thevalidrangefor
thethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45107

6TANV57CLI-35A

2-1351

Total Access/NetVanta Carrier CLI Dictionary

thresholds small-fragments 15-minute <0-4294967295>


Usethethresholdssmallfragments15minute<04294967295>commandtoconfigurethe15
minutesmallfragmentserrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssmallfragments15minute<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds small-fragments 15-minute 20
(config-efm-link 1/0/1)#

Functional Notes
Largefragmentsaredefinedtobefragmentsthatarelargerthan512bytes.Thevalidrangefor
thethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45121

2-1352

6TANV57CLI-35A

Section 2, Commands - EFM Link Interface Configuration Command Set

thresholds small-fragments 24-hour <0-4294967295>


Usethethresholdssmallfragments24hour<04294967295>commandtoconfigurethe15
minutesmallfragmenterrorsperformancemonitoringthreshold.Usethenoformofthis
commandtoreturnthethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssmallfragments24hour<0
4294967295>command.
(config-efm-link 1/0/1)#thresholds small-fragments 24-hour 100
(config-efm-link 1/0/1)#

Functional Notes
Smallfragmentsaredefinedtobefragmentsthataresmallerthan64bytes.Thevalidrangefor
thethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
45117

6TANV57CLI-35A

2-1353

Total Access/NetVanta Carrier CLI Dictionary

EFM Port Interface Configuration Command Set


UsetheEFMPortInterfaceConfigurationCommandSettoconfiguretheselectedEFMports.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface efm-port <shelf/slot/port>
ChassisId(config-efm-port x/x/x)#

ThefollowingisalistofcommandsavailableintheEFMPortInterfaceConfiguration
CommandSet.
exit
maclimit<1n>
portauthcontroldirection[both|in]
portautheapreq<110>
portauthportcontrol[auto|forceauthorized|forceunauthorized]
portauthreauthentication
portauthtimeouteapresponse<165535>
portauthtimeoutquietperiod<165535>
portauthtimeoutreauthperiod<14294967295>
portauthtimeoutserver<14294967295>
shutdown
shutdownunassigned

2-1354

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
78809

6TANV57CLI-35A

2-1355

Total Access/NetVanta Carrier CLI Dictionary

mac limit <1-n>


Usethemaclimit<1n>commandtoconfigurethemaxlimitoflearnedMACaddressesfor
theEFMportinterface.

Usage Examples
Thefollowingisanexampleofhowtousethemaclimit<1n>command.
(config-efm-port 1/9/3)#mac limit 8
(config-efm-port 1/9/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
63295

2-1356

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

port-auth control-direction [both|in]


Syntax Description
both

Blocktrafficinbothdirectionswhenunauthorized

in

Onlyblockincomingtrafficwhenunauthorized

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94139

6TANV57CLI-35A

2-1357

Total Access/NetVanta Carrier CLI Dictionary

port-auth eap-req <1-10>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94372

2-1358

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

port-auth port-control [auto|force-authorized|forceunauthorized]


Syntax Description
auto

EnabletheIEEE802.1xportauthenticationprocess

forceauthorized

Forcetheportintoanauthorizedstate

forceunauthorized

Forcetheportintoanunauthorizedstate

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94132

6TANV57CLI-35A

2-1359

Total Access/NetVanta Carrier CLI Dictionary

port-auth re-authentication
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94144

2-1360

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

port-auth timeout eap-response <1-65535>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94376

6TANV57CLI-35A

2-1361

Total Access/NetVanta Carrier CLI Dictionary

port-auth timeout quiet-period <1-65535>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94154

2-1362

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

port-auth timeout re-authperiod <1-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94150

6TANV57CLI-35A

2-1363

Total Access/NetVanta Carrier CLI Dictionary

port-auth timeout server <1-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2AM(1187121L1)

Command ID
94157

2-1364

6TANV57CLI-35A

Section 2, Commands - EFM Port Interface Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-efm-port 1/9/3)#shutdown
(config-efm-port 1/9/3)#
! To enable the interface:
(config-efm-port 1/9/3)#no shutdown
(config-efm-port 1/9/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
78685

6TANV57CLI-35A

2-1365

Total Access/NetVanta Carrier CLI Dictionary

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisabletheinterface(nodatais
passedthrough).Usethenoshutdowncommandtoenabletheinterfaceandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
(config-efm-port 1/9/3)#shutdown unassigned
(config-efm-port 1/9/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
94347

2-1366

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

ERPS Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface erps <shelf/slot/ring>
ChassisId(config-erps x/x/x)#

Functional Notes
Promptwillbeeither...(configqueueefmgroups/s/gq)#or(configqueueeths/s/g
q)#or(configqueuegigeths/s/gq)#oranyEthernetinterface
ThefollowingisalistofcommandsavailableintheERPSInterfaceConfigurationCommand
Set.
descriptionLINE
eastinterfacegigabitethernet<shelf/slot/port>
eastinterfacetengigabitethernet<shelf/slot/port>
exit
forceswitch[east|west]
guardtimer<102000>
rplowner[east|west]
shutdown[maintenance|unassigned]
waittorestore<5720>
westinterfacegigabitethernet<shelf/slot/port>
westinterfacetengigabitethernet<shelf/slot/port>

6TANV57CLI-35A

2-1367

Total Access/NetVanta Carrier CLI Dictionary

description LINE
Usethedescriptioncommandtoidentifythespecifiedinterface(forexample,circuitID,
contactinformation,etc.).Usethenoformofthiscommandtoremoveadescription.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78713

2-1368

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

east interface gigabit-ethernet <shelf/slot/port>


UsethiscommandtoconfiguretheSMBcardwiththeshelfandportnumberthatERPSwill
use.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83114

6TANV57CLI-35A

2-1369

Total Access/NetVanta Carrier CLI Dictionary

east interface ten-gigabit-ethernet <shelf/slot/port>


UsethiscommandtoconfiguretheSMBcardwiththeshelfandportnumberthatERPSwill
useat10gigabits.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83116

2-1370

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78797

6TANV57CLI-35A

2-1371

Total Access/NetVanta Carrier CLI Dictionary

force-switch [east|west]
Syntax Description
east

Eastringdirection

west

Westringdirection

Functional Notes
Setsaforcedswitchinonedirectiononthering.Thisisapersistentcommand.Whenaforce
switchissetonaspan,trafficonthatspanisblocked.TheexceptionisthatRapspacketsget
through.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
66065

2-1372

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

guard-timer <10-2000>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67068

6TANV57CLI-35A

2-1373

Total Access/NetVanta Carrier CLI Dictionary

rpl-owner [east|west]
Syntax Description
east

Configuretheeastdirectionasrpllinkontherplowner

west

Configurethewestdirectionasrpllinkontherplowner

Functional Notes
Configurethecurrentnodeasrplowner

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67073

2-1374

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.Use
theshutdownmaintenancecommandtoenabletheinterfacebutinhibitalarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-erps 1/1/1)#shutdown
(config-erps 1/1/1)#
! To disable the interface:
(config-erps 1/1/1)#shutdown unassigned
(config-erps 1/1/1)#
! To enable the interface:
(config-erps 1/1/1)#no shutdown
(config-erps 1/1/1)#
! To enable the interface but inhibit alarms:
(config-erps 1/1/1)#shutdown maintenance
(config-erps 1/1/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

6TANV57CLI-35A

2-1375

Total Access/NetVanta Carrier CLI Dictionary

Command ID
78698

2-1376

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

wait-to-restore <5-720>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67072

6TANV57CLI-35A

2-1377

Total Access/NetVanta Carrier CLI Dictionary

west interface gigabit-ethernet <shelf/slot/port>


UsethiscommandtoconfiguretheSMAcardwiththeshelfandportnumberthatERPSwill
use.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83119

2-1378

6TANV57CLI-35A

Section 2, Commands - ERPS Interface Configuration Command Set

west interface ten-gigabit-ethernet <shelf/slot/port>


UsethiscommandtoconfiguretheSMAcardwiththeshelfandportnumberthatERPSwill
useat10gigabits

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83121

6TANV57CLI-35A

2-1379

Total Access/NetVanta Carrier CLI Dictionary

Ethernet Interface Configuration Command Set


UsetheEthernetInterfaceConfigurationCommandSettoconfigure10/100Ethernetinter
facesasdefinedbyIEEE802.3.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface ethernet <shelf/slot/port>
ChassisId(config-eth x/x/x)#

Functional Notes
the10/100ethernetinterfaces
ThefollowingisalistofcommandsavailableintheEthernetInterfaceConfiguration
CommandSet.
crossover[auto|mdi|mdix]
descriptionLINE
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORD[down|up]
ethernetoamenable
exit
fullduplex
halfduplex
ipaddress[A.B.C.D|dhcp]
ipaddressA.B.C.DA.B.C.D
linkstateawareness
macagingtime<03600>
maclimit<1n>
shutdown
shutdownunassigned
speed[10|100|auto]
stagdei
subtendedhostezprovisioning
subtendedhostipaddressA.B.C.DP.Q.R.S
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|listener|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD
subtendedhostsnmpservercommunityreadwriteWORD
subtendedhostsnmpserverezprovisioninghostA.B.C.Dtrapsversion[1|2c]

2-1380

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtendedhostsnmpserverlocationWORD
subtendedhoststag<14094>
subtendedhoststagpriority<07>
thresholdsbroadcasts15minute<04294967295>
thresholdsbroadcasts24hour<04294967295>
thresholdscollisions15minute<04294967295>
thresholdscollisions24hour<04294967295>
thresholdsdiscards15minute<04294967295>
thresholdsdiscards24hour<04294967295>
thresholdserrors15minute<04294967295>
thresholdserrors24hour<04294967295>
thresholdsgiants15minute<04294967295>
thresholdsgiants24hour<04294967295>
thresholdsinvalidvlan15minute<04294967295>
thresholdsinvalidvlan24hour<04294967295>
thresholdslinkstateawarenessbandwidthminimum<02147483647>
thresholdslinkstateawarenesslinksminimum<0n>
thresholdsmulticasts15minute<04294967295>
thresholdsmulticasts24hour<04294967295>
thresholdspeakmacentries15minute<0n>
thresholdspeakmacentries24hour<0n>
thresholdsrunts15minute<04294967295>
thresholdsrunts24hour<04294967295>

6TANV57CLI-35A

2-1381

Total Access/NetVanta Carrier CLI Dictionary

crossover [auto|mdi|mdi-x]
Usethecrossover[auto|mdi|mdix]commandtoconfiguretheEthernetportforusewitha
crossovercableorastraightcable.Acrossovercableisrequiredfortwolikeportconfigura
tionsandastraightcableisusedbetweentwoportswithdifferentconfigurations.

Syntax Description
auto

AutomaticallychoosebetweenMDIandMDIX

mdi

Standardtransmitandreceivepinout

mdix

Reversedtransmitandreceivepinout

Usage Examples
Thefollowingisanexampleofhowtousethecrossover[auto|mdi|mdix]command.
(config-eth 1/0/1)#crossover auto
(config-eth 1/0/0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCMG2(1187010G2),SCMwithBridging(1187011G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44654

2-1382

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedEthernetinterface.Usetheno
formofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-eth 1/0/2)#description Eth Port #2
(config-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
78721

6TANV57CLI-35A

2-1383

Total Access/NetVanta Carrier CLI Dictionary

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
64530

2-1384

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

ethernet cfm enable


UsetheethernetcfmenablecommandtoenabletheethernetOAMconnectivityfault
managementsubsystemandallocateresources.Usethenoformofthiscommandtodisable
thesubsystem,causingallCFMfunctionstoceaseanddeallocateresources.Anyexisting
CFMconfigurationisretained,butnoframesaresentorreceivedandnoresourcesare
consumedotherthanspaceintheconfiguration.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmenablecommand.
! To enable the ethernet OAM connectivity fault management subsystem:
(config-eth 1/0/1)#ethernet cfm
(config-eth 1/0/1)#
! To disable the ethernet OAM connectivity fault management subsystem:
(config-eth 1/0/1)#no ethernet cfm
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
120307

6TANV57CLI-35A

2-1385

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm mep <1-8191> WORD WORD [down|up]


Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

down

Facingthephysicalport

up

Facingtheswitchingelement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
64535

2-1386

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
120326

6TANV57CLI-35A

2-1387

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
78801

2-1388

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

full-duplex
UsethefullduplexcommandtoconfiguretheEthernetportforfullduplexoperation
allowingtheporttosendandreceivesimultaneously.

Usage Examples
Thefollowingisanexampleofhowtousethefullduplexcommand.
(config-eth 1/0/1)#full-duplex
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44638

6TANV57CLI-35A

2-1389

Total Access/NetVanta Carrier CLI Dictionary

half-duplex
UsethehalfduplexcommandtoconfiguretheEthernetportforhalfduplexoperation
allowingtheporttoeithersendorreceiveatanygivenmomentbutnotsimultaneously.

Usage Examples
Thefollowingisanexampleofhowtousethehalfduplexcommand.
(config-eth 1/0/1)#half-duplex
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44636

2-1390

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

ip address [A.B.C.D|dhcp]
Syntax Description
A.B.C.D

IPaddress

dhcp

EnableDHCPclient

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
65543

6TANV57CLI-35A

2-1391

Total Access/NetVanta Carrier CLI Dictionary

ip address A.B.C.D A.B.C.D


UsetheipaddressA.B.C.DA.B.C.Dtosettheipaddressandnetmaskoftheinterface.Usethe
nofromtosettheipaddressandnetmasktothedefaultvalues.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousetheipaddressA.B.C.DA.B.C.Dcommand.
(config-eth 1/S/1)#ip address 1.2.3.4 255.255.255.0
(config-eth 1/S/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65549

2-1392

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

link-state-awareness
UsethelinkstateawarenesscommandtoenablelinkstateawarenessfortheselectedEthernet
port.ForEFMgroupbasedMENports,thelinkstateawarenessfeature,whenenabled,shuts
downtheEthernetportifalloftheMENportstowhichtrafficismappedbecomeunavailable.
Usethenoformofthiscommandtodisablelinkstateawareness.

Usage Examples
Thefollowingisanexampleofhowtousethelinkstateawarenesscommand.
(config-eth 1/0/1)#link-state-awareness
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44662

6TANV57CLI-35A

2-1393

Total Access/NetVanta Carrier CLI Dictionary

mac aging-time <0-3600>


Usethemacagingtime<03600>commandtoconfiguretheMACagingtimeinseconds.
Value0forceslearnandlock.Minvalueis5secondsandmax3600seconds.

Usage Examples
Thefollowingisanexampleofhowtousethemacagingtime<03600>command.
838_112(config-eth 1/0/2)#mac aging-time 50
838_112(config-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
89686

2-1394

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

mac limit <1-n>


Usethemaclimit<1n>commandtoconfigurethemaximumnumberoflearnedMAC
addressesoftheselectedEthernetport.Usethenoformofthiscommandtodisablemac
limiting.

Usage Examples
Thefollowingisanexampleofhowtousethemaclimit<1n>command.
(config-eth 1/0/1)#mac limit 50
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44649

6TANV57CLI-35A

2-1395

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-eth 1/0/1)#shutdown
(config-eth 1/0/1)#
! To enable the interface:
(config-eth 1/0/1)#no shutdown
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
78690

2-1396

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisabletheinterface(nodatais
passedthrough).Usethenoshutdowncommandtoenabletheinterfaceandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
(config-eth 1/0/1)#shutdown unassigned
(config-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
94348

6TANV57CLI-35A

2-1397

Total Access/NetVanta Carrier CLI Dictionary

speed [10|100|auto]
UsethespeedcommandtoconfigurethespeedoftheEthernetinterface.

Syntax Description
10

Configuretheethernetfor10Mbpsoperation

100

Configuretheethernetfor100Mbpsoperation

auto

Configuretheethernetforautomaticspeeddetection

Usage Examples
Thefollowingisanexampleofhowtousethespeed[10|100|auto]command.
(config-eth 1/0/1)#speed 100

Functional Notes
Syntax:
autoUsethissyntaxtoautomaticallydetect10or100MbpsEthernetandnegotiatethe
duplexsetting.
10Usethissyntaxtospecify10MbpsEthernet.
100Usethissyntaxtospecify100MbpsEthernet.
Thedefaultvalueisauto.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCMG2(1187010G2),SCMwithBridging(1187011G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
44640

2-1398

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
96568

6TANV57CLI-35A

2-1399

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ez-provisioning
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
138309

2-1400

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host ip address A.B.C.D P.Q.R.S


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipaddressA.B.C.DP.Q.R.S
command.
(config-efm-group 1/18/1)#subtended-host ip address 192.168.0.2
255.255.255.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104921

6TANV57CLI-35A

2-1401

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipdefaultgatewayA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip default-gateway 192.168.0.254

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104923

2-1402

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Usage Examples
Thefollowingisanexampleofhowtousethesubtendedhostipfileserverdefaulthost
A.B.C.Dcommand.
(config-efm-group 1/18/1)#subtended-host ip file-server default host
192.168.0.1

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104927

6TANV57CLI-35A

2-1403

Total Access/NetVanta Carrier CLI Dictionary

subtended-host mode [disabled|listener|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

listener

Acceptssubtendedhostparametersfromconnecteddevice

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104941

2-1404

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104940

6TANV57CLI-35A

2-1405

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104938

2-1406

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104936

6TANV57CLI-35A

2-1407

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server ez-provisioning host A.B.C.D


traps version [1|2c]
Syntax Description
A.B.C.D

IPaddress

Version1

2c

Version2c

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
138299

2-1408

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host snmp-server location WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
138308

6TANV57CLI-35A

2-1409

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag <1-4094>


ThiscommandisusedtosettheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104929

2-1410

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
104932

6TANV57CLI-35A

2-1411

Total Access/NetVanta Carrier CLI Dictionary

thresholds broadcasts 15-minute <0-4294967295>


Usethethresholdsbroadcasts15minute<04294967295>commandtoconfigurethealarm
thresholdforthebroadcastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts15minute<0
4294967295>command.
(config-eth 1/0/1)#thresholds broadcasts 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44730

2-1412

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds broadcasts 24-hour <0-4294967295>


Usethethresholdsbroadcasts24hour<04294967295>commandtoconfigurethealarm
thresholdforthebroadcastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds broadcasts 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44732

6TANV57CLI-35A

2-1413

Total Access/NetVanta Carrier CLI Dictionary

thresholds collisions 15-minute <0-4294967295>


Usethethresholdscollisions15minute<04294967295>commandtoconfigurethealarm
thresholdforthecollisionsoccurringina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscollisions15minute<04294967295>
command.
(config-eth 1/0/1)#thresholds collisions 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44700

2-1414

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds collisions 24-hour <0-4294967295>


Usethethresholdscollisions24hour<04294967295>commandtoconfigurethealarm
thresholdforthecollisionsoccurringina24hourperiod.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscollisions24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds collisions 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44702

6TANV57CLI-35A

2-1415

Total Access/NetVanta Carrier CLI Dictionary

thresholds discards 15-minute <0-4294967295>


Usethethresholdsdiscards15minute<04294967295>commandtoconfigurethealarm
thresholdforthediscardedframesoccurringina15minuteperiod.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards15minute<04294967295>
command.
(config-eth 1/0/1)#thresholds discards 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44710

2-1416

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds discards 24-hour <0-4294967295>


Usethethresholdsdiscards24hour<04294967295>commandtoconfigurethealarm
thresholdforthediscardedframesoccurringina24hourperiod.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds discards 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44712

6TANV57CLI-35A

2-1417

Total Access/NetVanta Carrier CLI Dictionary

thresholds errors 15-minute <0-4294967295>


Usethethresholdserrors15minute<04294967295>commandtoconfigurethealarm
thresholdfortheCRCerrorsoccurringina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors15minute<04294967295>
command.
(config-eth 1/0/1)#thresholds errors 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44670

2-1418

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds errors 24-hour <0-4294967295>


Usethethresholdserrors24hour<04294967295>commandtoconfigurethealarmthreshold
fortheCRCerrorsoccurringina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds errors 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44672

6TANV57CLI-35A

2-1419

Total Access/NetVanta Carrier CLI Dictionary

thresholds giants 15-minute <0-4294967295>


Usethethresholdsgiants15minute<04294967295>commandtoconfigurethealarm
thresholdfortheoversizedframesoccurringina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants15minute<04294967295>
command.
(config-eth 1/0/1)#thresholds giants 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44690

2-1420

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds giants 24-hour <0-4294967295>


Usethethresholdsgiants24hour<04294967295>commandtoconfigurethealarmthreshold
fortheoversizedframesoccurringina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds giants 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44692

6TANV57CLI-35A

2-1421

Total Access/NetVanta Carrier CLI Dictionary

thresholds invalid-vlan 15-minute <0-4294967295>


Usethethresholdsinvalidvlan15minute<04294967295>commandtoconfigurethealarm
thresholdfortheframesreceivedwithaninvalidVLANina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan15minute<0
4294967295>command.
(config-eth 1/0/1)#thresholds invalid-vlan 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
82023

2-1422

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds invalid-vlan 24-hour <0-4294967295>


Usethethresholdsinvalidvlan24hour<04294967295>commandtoconfigurethealarm
thresholdfortheframesreceivedwithaninvalidVLANina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds invalid-vlan 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
82025

6TANV57CLI-35A

2-1423

Total Access/NetVanta Carrier CLI Dictionary

thresholds link-state-awareness bandwidth-minimum <02147483647>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142679

2-1424

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds link-state-awareness links-minimum <0-n>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142681

6TANV57CLI-35A

2-1425

Total Access/NetVanta Carrier CLI Dictionary

thresholds multicasts 15-minute <0-4294967295>


Usethethresholdsmulticasts15minute<04294967295>commandtoconfigurethealarm
thresholdforthemulticastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts15minute<0
4294967295>command.
(config-eth 1/0/1)#thresholds multicasts 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44720

2-1426

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds multicasts 24-hour <0-4294967295>


Usethethresholdsmulticasts24hour<04294967295>commandtoconfigurethealarm
thresholdforthemulticastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds multicasts 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44722

6TANV57CLI-35A

2-1427

Total Access/NetVanta Carrier CLI Dictionary

thresholds peak-mac-entries 15-minute <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries15minute<0n>
command.
838_112(config-eth 1/0/2)#thresholds peak-mac-entries 15-minute 20
838_112(config-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
89696

2-1428

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds peak-mac-entries 24-hour <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries24hour<0n>
command.
838_112(config-eth 1/0/2)#thresholds peak-mac-entries 24-hour 60
838_112(config-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
89698

6TANV57CLI-35A

2-1429

Total Access/NetVanta Carrier CLI Dictionary

thresholds runts 15-minute <0-4294967295>


Usethethresholdsrunts15minute<04294967295>commandtoconfigurethealarm
thresholdforundersizedframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts15minute<04294967295>
command.
(config-eth 1/0/1)#thresholds runts 15-minute 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44680

2-1430

6TANV57CLI-35A

Section 2, Commands - Ethernet Interface Configuration Command Set

thresholds runts 24-hour <0-4294967295>


Usethethresholdsrunts24hour<04294967295>commandtoconfigurethealarmthreshold
forundersizedframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts24hour<04294967295>
command.
(config-eth 1/0/1)#thresholds runts 24-hour 1000
(config-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
44682

6TANV57CLI-35A

2-1431

Total Access/NetVanta Carrier CLI Dictionary

Ethernet OAM Association Configuration Command Set


UsetheEthernetOAMAssociationConfigurationCommandSettomodifyanIEEE802.1ag
ConnectivityFaultManagementmaintenanceassociation.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ethernet cfm domain char-string * level * index <1-n>
ChassisId(config-ecfm-domain name)#association char-string * index <1-n>
ChassisId(config-ecfm-assoc name)#

ThefollowingisalistofcommandsavailableintheEthernetOAMAssociationConfiguration
CommandSet.
ccminterval[100milliseconds|10minutes|10seconds|1minute|1second]
ccmenabled
component<1n>vlan[<14094>|none]
exit
mepdatabase[autodiscovery|clear|configuredonly|lock]
mepdatabaseautodiscoveryautolearn
mepdatabaseclear<18191>
mepdatabaselock<18191>
mepshutdown
mepvalidation
mepvalidationstartdelay<165535>
remotemep<18191>

2-1432

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

ccm interval [100-milliseconds|10-minutes|10-seconds|1minute|1-second]


Usetheccminterval[1minute|1second|10minutes|10seconds|100milliseconds]
commandtosettheCCMintervalforMEPsintheselectedassociation.Usethenoformofthis
commandtosettheCCMintervaltothedefaultofonesecond.

Syntax Description
100milliseconds

100milliseconds

10minutes

10minutes

10seconds

10seconds

1minute

1minute

1second

1second

Usage Examples
Thefollowingisanexampleofhowtousetheccminterval[100milliseconds|10minutes|10
seconds|1minute|1second]command.
(config-ecfm-assoc MA_1)#ccm interval 1-second
(config-ecfm-assoc MA_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM2GE(1187020G1),SM10GE(1187025G1),SM10GE(1187030G1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G2),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45230

6TANV57CLI-35A

2-1433

Total Access/NetVanta Carrier CLI Dictionary

ccm-enabled
UsetheccmenabledcommandtoenabletransmissionofCCMsbytheMEPsinthemainte
nanceassociation.UsethenoformofthecommandtodisabletheMEPsfromtransmitting
CCMs.Whendisabled,aMEPceasestosendCCMframesbutcontinuestoprocessreceived
CCMs.

Usage Examples
Thefollowingisanexampleofhowtousetheccmenabledcommand.
(config-ecfm-assoc MA_1)#ccm-enabled
(config-ecfm-assoc MA_1)#

Functional Notes
TheccmenabledcommandisexecutedimmediatelytomodifythesettingofeveryMEP
currentlybelongingtotheassociation.Itisnotstoredaspartoftheconfigurationoftheassoci
ation,therefore,ithasnoeffectonanyMEPsthatmightbeaddedlater.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45227

2-1434

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

component <1-n> vlan [<1-4094>|none]


Usethecomponent<1n>vlan<14094>commandtoactivatetheEthernetOAMComponent
ConfigurationCommandSetandtocreateaCFMComponentinthemaintenanceassociation
configuredtousethespecifiedprimaryVID.ReenteringthesamecomponentIDwitha
differentVIDvalueoverwritesthepreviousprimaryVID.

Syntax Description
<1n>

EnterComponentID

<14094>

EnterVLANID

none

NotassociatedwithanyVLAN

Usage Examples
Thefollowingisanexampleofhowtousethecomponent<1n>vlan[<14094>|none]
command.
(config-ecfm-assoc MA_1)#component 1 vlan 1000
(config-ecfm-comp1)#

Functional Notes
Usethe<1n>inputtoenterthecomponentID.ThevalidvalueforthecomponentIDis
limitedto1forsystemrelease4.1.
ThevalidrangefortheVLANIDis1to4094.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45246

6TANV57CLI-35A

2-1435

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45223

2-1436

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

mep-database [auto-discovery|clear|configured-only|lock]
Usethemepdatabase[autodiscovery|clear|configuredonly|lock]commandtoconfigure
theMEPdatabasefortheselectedassociation.

Syntax Description
autodiscovery

DiscoverremoteMEPsandaddtodatabaseasdiscoveredentries

clear

CleardiscoveredpeerMEPentries

configuredonly

ReceivedCCMsmustmatchconfiguredpeerMEPlist

lock

TransitionpeerMEPentriesfromdiscoveredtostatic

Usage Examples
Thefollowingisanexampleofhowtousethemepdatabase[auto
discovery|clear|configuredonly|lock]command.
(config-ecfm-assoc MA_1)#mep-database auto-discovery
(config-ecfm-assoc MA_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
83076

6TANV57CLI-35A

2-1437

Total Access/NetVanta Carrier CLI Dictionary

mep-database auto-discovery auto-learn


UsethemepdatabaseautodiscoveryautolearncommandtodiscoverremoteMEPsandadd
theremoteMEPstotheMEPdatabaseasstaticentries.AlearnedremoteMEPisstoredin
provisioningonthenextwriteandalsoactivatesiftheMEPentersthefailedstate.

Usage Examples
Thefollowingisanexampleofhowtousethemepdatabaseautodiscoveryautolearn
command.
(config-ecfm-assoc MA_1)#mep-database auto-discovery auto-learn
(config-ecfm-assoc MA_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
83080

2-1438

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

mep-database clear <1-8191>


Usethemepdatabaseclear<18191>commandtoclearadiscoveredpeerMEPfromthe
maintenanceassociationMEPdatabase.

Usage Examples
Thefollowingisanexampleofhowtousethemepdatabaseclear<18191>command.
(config-ecfm-assoc MA_1)#mep-database clear 401
(config-ecfm-assoc MA_1)#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.TheremoteMEP(RMEP)IDenteredmustbea
discoveredRMEP.AdiscoveredRMEPisdetonatedbya*precedingtheID.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
83084

6TANV57CLI-35A

2-1439

Total Access/NetVanta Carrier CLI Dictionary

mep-database lock <1-8191>


Usethemepdatabaselock<18191>commandtotransitionadiscoveredpeerMEPentrytoa
staticentry.

Usage Examples
Thefollowingisanexampleofhowtousethemepdatabaselock<18191>command.
(config-ecfm-assoc MA_1)#mep-database lock 401
(config-ecfm-assoc MA_1)#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.TheRMEPIDenteredmustbeadiscovered
RMEP.AdiscoveredRMEPisdetonatedbya*precedingtheID.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
83082

2-1440

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

mep-shutdown
Usethemepshutdowncommandtosettheadministrativestatetodisabledforallmember
MEPsintheselectedmaintenanceassociation.ThiscausesallMEPfunctionalitytohaltinthe
selectedmaintenanceassociation.Usethenoformofthiscommandtosetthestatetoenabled.

Usage Examples
Thefollowingisanexampleofhowtousethemepshutdowncommand.
! To disable all member MEPs:
(config-ecfm-assoc MA_1)#mep-shutdown
(config-ecfm-assoc MA_1)#
! To enable all member MEPs:
(config-ecfm-assoc MA_1)#no mep-shutdown
(config-ecfm-assoc MA_1)#

Functional Notes
ThemepshutdowncommandisexecutedimmediatelytomodifythesettingofeveryMEP
currentlybelongingtotheassociation.Itisnotstoredaspartoftheconfigurationoftheassoci
ation,therefore,ithasnoeffectonanyMEPsthatmightbeaddedlater.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45225

6TANV57CLI-35A

2-1441

Total Access/NetVanta Carrier CLI Dictionary

mep-validation
UsethemepvalidationcommandtoenablerecognitionofalarmsforstaticremoteMEPsand
validationofreceivedContinuityCheckMessages(CCMs).Usethenoformofthiscommand
todisableMEPvalidation.

Usage Examples
Thefollowingisanexampleofhowtousethemepvalidationcommand.
(config-ecfm-assoc MA_1)#mep-validation
(config-ecfm-assoc MA_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45235

2-1442

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Association Configuration Command Set

mep-validation start-delay <1-65535>


Usethemepvalidationstartdelay<165535>commandtoenterthetimeinsecondstodelay
beforevalidatingCCMsreceivedfromremoteMEPs.

Usage Examples
Thefollowingisanexampleofhowtousethemepvalidationstartdelay<165535>
command.
(config-ecfm-assoc MA_1)#mep-validation start-delay 300
(config-ecfm-assoc MA_1)#

Functional Notes
Thevalidrangeforthedelayis1to65535seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45237

6TANV57CLI-35A

2-1443

Total Access/NetVanta Carrier CLI Dictionary

remote-mep <1-8191>
Usetheremotemep<18191>commandtopopulatetheMEPlisttablefortheselectedmainte
nanceassociation.UsethenoformofthiscommandtoremovetheremoteMEPentryfromthe
listandclearanyinformationfromtheremoteMEPthatisintheMEPCCMdatabase.

Usage Examples
Thefollowingisanexampleofhowtousetheremotemep<18191>command.
(config-ecfm-assoc MA_1)#remote-mep 102
(config-ecfm-assoc MA_1)#

Functional Notes
ThevalidrangefortheMEPIDis1to8191.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45241

2-1444

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Component Configuration Command Set

Ethernet OAM Component Configuration Command Set


UsetheEthernetOAMComponentConfigurationCommandSettomodifyanIEEE802.1ag
ConnectivityFaultManagementmaintenanceassociationcomponent.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ethernet cfm domain char-string * level * index <1-n>
ChassisId(config-ecfm-domain name)#association char-string * index <1-n>
ChassisId(config-ecfm-assoc name)#component * vlan <1-4094>
ChassisId(config-ecfm-compx)#

ThefollowingisalistofcommandsavailableintheEthernetOAMComponentConfiguration
CommandSet.
exit
mipallowed[any|anywithmep|defer|none]
mpsenderid[chassisid|defer|managementaddress|none]
mpsenderidchassisidmanagementaddress

6TANV57CLI-35A

2-1445

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45256

2-1446

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Component Configuration Command Set

mip-allowed [any|any-with-mep|defer|none]
Usethemipallowed[any|anywithmep|defer|none]commandtoconfiguretheMIPcreate
rulefortheVLANatthemaintenancedomainlevel.Theruleistakenintoaccountwhen
determiningifaMIPisgoingtobecreatedontheVLAN,andifso,atwhatlevel.Theruleis
checked,aswellas,allothermaintenanceassociationcomponentrulesthatareusingthesame
VLANbutareindifferentmaintenancedomains.

Syntax Description
any

MHFscanbecreatedonthisVIDonanyBridgePort

anywithmep

MHFscanbecreatedonthisVIDonanyBridgePortwithMEPat
lowerMDlevel

defer

DeferMHFcreationruletoparentMaintenanceDomain

none

NoMHFscanbecreatedfortheVID

Usage Examples
Thefollowingisanexampleofhowtousethemipallowed[any|anywithmep|defer|none]
command.
(config-ecfm-comp1)#mip-allowed any
(config-ecfm-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78015

6TANV57CLI-35A

2-1447

Total Access/NetVanta Carrier CLI Dictionary

mp-sender-id [chassis-id|defer|management-address|none]
Usethempsenderid[chassisid|managementaddress|none]commandtoenablethesender
IDTLVforpacketsthatbelongtoMEPsassignedtotheassociation.Whenconfigured,this
settingtakesprecedenceoverthesamesettingintheparentassociation.Usethenoformof
thiscommandtoreturntothesettingspecifiedintheparentassociation.

Syntax Description
chassisid

SendchassisidinthesenderIDTLV

defer

DefersenderIDTLVruletoparentMaintenanceDomain

managementaddress

SendmanagementaddressinthesenderIDTLV

none

DonotsendthesenderIDTLV

Usage Examples
Thefollowingisanexampleofhowtousethempsenderid[chassisid|defer|management
address|none]command.
(config-ecfm-comp1)#mp-sender-id none
(config-ecfm-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45258

2-1448

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Component Configuration Command Set

mp-sender-id chassis-id management-address


UsethempsenderidchassisidmanagementaddresscommandtosendboththechassisID
andmanagementaddressinthesenderIDTLV.

Usage Examples
Thefollowingisanexampleofhowtousethempsenderidchassisidmanagementaddress
command.
(config-ecfm-comp1)#mp-sender-id chassis-id management-address
(config-ecfm-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45262

6TANV57CLI-35A

2-1449

Total Access/NetVanta Carrier CLI Dictionary

Ethernet OAM Default Domain Component Configuration


Command Set
UsetheEthernetOAMDefaultDomainComponentConfigurationCommandSettomodify
anIEEE802.1agConnectivityFaultManagementdefaultdomaincomponent.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ethernet cfm default-domain
ChassisId(config-ecfm-def-domain)#component * vlan <1-4094>
ChassisId(config-ecfm-def-compx)#

ThefollowingisalistofcommandsavailableintheEthernetOAMDefaultDomain
ComponentConfigurationCommandSet.
exit
level[<07>|defer]
mipallowed[any|anywithmep|defer|none]
mipsenderid[chassisid|defer|managementaddress|none]
mipsenderidchassisidmanagementaddress

2-1450

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Component Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78089

6TANV57CLI-35A

2-1451

Total Access/NetVanta Carrier CLI Dictionary

level [<0-7>|defer]
Usethelevel[07|defer]commandtosetthedefaultdomainMIPlevelforthisVLANin
component1.

Syntax Description
<07>

Enterlevel

defer

DeferMHFlevelvaluetoDefaultDomainglobalsetting

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78076

2-1452

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Component Configuration Command Set

mip-allowed [any|any-with-mep|defer|none]
Usethemipallowed[any|anywithmep|none|defer]commandtoconfigurethedefault
domainMIPcreateruleforthisVLANincomponent1.Thisruleistakenintoaccountwhen
determiningifaMIPisgoingtobecreatedonthisVLANandifsowhatlevel.Thisruleis
checkedaswellasallotherMaintenanceAssociationComponentrulesthatareusingthe
sameVLAN.Thenoversionofthiscommandsetsthisbacktothedefaultvalueofdefer.

Syntax Description
any

AllowsMIPstobecreatedontheVLAN

anywithmep

AllowsMIPstobecreatedoniftheportcontainsalowerlevel
MEP

defer

DeferMHFcreationruletoDefaultDomainglobalsetting

none

DonotallowMIPstobecreatedonthisVLAN

Usage Examples
Thefollowingisanexampleofhowtousethemipallowed[any|anywithmep|defer|none]
command.
(config-ecfm-def-comp1)#mip-allowed any
(config-ecfm-def-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78069

6TANV57CLI-35A

2-1453

Total Access/NetVanta Carrier CLI Dictionary

mip-sender-id [chassis-id|defer|management-address|none]
Usethemipsenderid[chassisid|managementaddress|none]commandtoenablethe
senderIDTLVforLinktraceReplypacketssentbyMIPsthatwerecreatedattheleveldefined
inthedefaultdomainforthisVLANincomponent1.Thissettingoverridestheglobal
defaultdomainsetting.Usethenoformofthiscommandtosetitbacktothedefaultsettingof
defer.

Syntax Description
chassisid

SendchassisidinthesenderIDTLV

defer

DeferthesenderIDTLVvaluetotheglobalDefaultDomain
setting

managementaddress

SendmanagementaddressinthesenderIDTLV

none

DonotsendthesenderIDTLV

Usage Examples
Thefollowingisanexampleofhowtousethemipsenderid[chassisid|defer|management
address|none]command.
(config-ecfm-def-comp1)#mip-sender-id chassis-id
(config-ecfm-def-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78081

2-1454

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Component Configuration Command Set

mip-sender-id chassis-id management-address


UsethemipsenderidchassisidmanagementaddresscommandtoenablethesenderIDTLV
forLinktraceReplypacketssentbyMIPsthatwerecreatedattheleveldefinedinthedefault
domainforthisVLANincomponent1.Thissettingoverridestheglobaldefaultdomain
setting.TheSenderIDTLVwillcontainboththechassisidandmanagementaddress.Usethe
noformofthiscommandtosetitbacktothedefaultsettingofdefer.

Usage Examples
Thefollowingisanexampleofhowtousethemipsenderidchassisidmanagementaddress
command.
(config-ecfm-def-comp1)#mip-sender-id chassis-id management-address
(config-ecfm-def-comp1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78084

6TANV57CLI-35A

2-1455

Total Access/NetVanta Carrier CLI Dictionary

Ethernet OAM Default Domain Configuration Command Set


UsetheEthernetOAMDefaultDomainConfigurationCommandSettomodifytheIEEE
802.1agConnectivityFaultManagementdefaultdomain.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ethernet cfm default-domain
ChassisId(config-ecfm-def-domain)#

ThefollowingisalistofcommandsavailableintheEthernetOAMDefaultDomainConfigu
rationCommandSet.
component<1n>vlan<14094>
exit
mipalloweddefault[any|anywithmep|none]
mipleveldefault<07>
mipsenderiddefault[chassisid|managementaddress|none]
mipsenderiddefaultchassisidmanagementaddress

2-1456

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Configuration Command Set

component <1-n> vlan <1-4094>


Usethecomponent<1n>vlan<14094>commandtoactivatetheEthernetOAMDefault
DomainComponentConfigurationCommandSetforthespecifiedVLAN.Entriescannotbe
removedoradded,onlyaccessed.VLANentriesareeligibletobeaccessedinthedefault
domainoncetheyaredefinedbyanEVCordefinedinaEthernetOAMMaintenanceAssoci
ationComponent.

Syntax Description
<1n>

Entercomponent

Usage Examples
Thefollowingisanexampleofhowtousethecomponent<1n>vlan<14094>command.
(config-ecfm-def-domain)#component 1 vlan 1000
(config-ecfm-def-comp1)#

Functional Notes
ThevalidvalueforthecomponentIDislimitedto1forSR4.1.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78055

6TANV57CLI-35A

2-1457

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78066

2-1458

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Configuration Command Set

mip-allowed-default [any|any-with-mep|none]
Usethemipalloweddefault[any|anywithmep|none]commandtosettheglobaldefault
domainMIPcreaterule.ThisruleistakenintoaccountwhendeterminingifaMIPcanbe
createdonaVLANconfiguredinacomponent.ThisvalueisusedbyVLANsinthedefault
domaincomponent1thataresettothevalueofdefer.Thenoversionofthiscommandsets
thistothedefaultvalueofnone.

Syntax Description
any

AllowsMIPstobecreatedontheVLAN

anywithmep

AllowsMIPstobecreatedonlyiftheportcontainsalowerlevel
MEP

none

DoesnotallowMIPstobecreatedontheVLAN

Usage Examples
Thefollowingisanexampleofhowtousethemipalloweddefault[any|anywith
mep|none]command.
(config-ecfm-def-domain)#mip-allowed-default any
(config-ecfm-def-domain)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78039

6TANV57CLI-35A

2-1459

Total Access/NetVanta Carrier CLI Dictionary

mip-level-default <0-7>
Usethemipleveldefault<07>commandtosettheglobaldefaultdomainMIPlevel.This
levelistakenintoaccountwhendeterminingatwhichlevelaMIPisgoingtobecreatedat.
ThisvalueisusedbyVLANsinthedefaultdomaincomponent1thataresettothedeferred
valueof1.Thenoversionofthiscommandsetsthisvalueto0.

Usage Examples
Thefollowingisanexampleofhowtousethemipleveldefault<07>command.
(config-ecfm-def-domain)#mip-level-default 5
(config-ecfm-def-domain)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78029

2-1460

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Default Domain Configuration Command Set

mip-sender-id-default [chassis-id|management-address|none]
Usethemipsenderiddefault[chassisid|managementaddress|none]commandtoenable
thesenderIDTLVforLinktraceReplypacketssentbyMIPsthatwerecreatedatthelevel
definedinthedefaultdomain.ThissettingisusedwhenaMIPsparentcomponentmp
senderidvalueissettodefer.Usethenoformofthiscommandtosetitbacktothedefault
settingofnone.

Syntax Description
chassisid

SendchassisidinthesenderIDTLV

managementaddress

SendmanagementaddressinthesenderIDTLV

none

DonottransmitthesenderIDTLV

Usage Examples
Thefollowingisanexampleofhowtousethemipsenderiddefault[chassis
id|managementaddress|none]command.
(config-ecfm-def-domain)#mip-sender-id-default chassis-id
(config-ecfm-def-domain)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78045

6TANV57CLI-35A

2-1461

Total Access/NetVanta Carrier CLI Dictionary

mip-sender-id-default chassis-id management-address


Usethemipsenderiddefaultchassisidmanagementaddresscommandtosendboththe
chassisIDandmanagementaddressinthesenderIDTLV.Usethenoformofthiscommand
tosetitbacktothedefaultsettingofnone.

Usage Examples
Thefollowingisanexampleofhowtousethemipsenderiddefaultchassisidmanagement
addresscommand.
(config-ecfm-def-domain)#mip-sender-id-default chassis-id managementaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
78048

2-1462

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Domain Configuration Command Set

Ethernet OAM Domain Configuration Command Set


UsetheEthernetOAMDomainConfigurationCommandSettomodifyanIEEE802.1ag
ConnectivityFaultManagementmaintenancedomain.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ethernet cfm domain char-string * level * index <1-n>
ChassisId(config-ecfm-domain name)#

ThefollowingisalistofcommandsavailableintheEthernetOAMDomainConfiguration
CommandSet.
associationcharstringWORD
associationcharstringWORDindex<1n>
ccmenabled
exit
mepshutdown
mipallowed[any|anywithmep|none]
mpsenderid[chassisid|managementaddress|none]
mpsenderidchassisidmanagementaddress

6TANV57CLI-35A

2-1463

Total Access/NetVanta Carrier CLI Dictionary

association char-string WORD


UsetheassociationcommandtocreateaCFMmaintenanceassociationinthisMaintenance
DomainandactivatetheMaintenanceAssociationConfigurationCommandSet.Usetheno
formofthiscommandtodeletethespecifiedmaintenanceassociation,includingallremote
MEPsentriesandlocalMEPsentriesdefinedonaninterfacethatreferencethespecified
association.

Usage Examples
ThefollowingisanexampleofhowtousetheassociationcharstringWORDcommand.
(config-ecfm-domain MD_1)#association char-string MA_1
(config-ecfm-assoc MA_1)#

Functional Notes
ThepromptchangesasverificationthattheComponentConfigurationcommandsare
available.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45215

2-1464

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Domain Configuration Command Set

association char-string WORD index <1-n>


UsetheassociationcharstringWORDindex<1n>commandtoactivatetheEthernetOAM
AssociationConfigurationCommandSetandtocreateaCFMmaintenanceassociationspeci
fyingtheMIBindexandmaintenanceassociationname.Theindexallowsvisibilityand
controloftheCFMasitresidesintheMIB.Ifavalueisnotspecified,thesystemassignsa
valueandaddsthevaluetothecommandintherunningconfiguration.Usethenoformof
thiscommandtodeletethespecifiedmaintenanceassociationincludinganyMEPsdefinedon
aninterfacethatreferencesthespecifiedassociation.

Syntax Description
WORD

Enternameofassociation

Usage Examples
ThefollowingisanexampleofhowtousetheassociationcharstringWORDindex<1n>
command.
(config-ecfm-domain MD_1)#association char-string MA_1
(config-ecfm-assoc MA_1)#

Functional Notes
UsetheWORDinputtospecifythemaintenanceassociationname.Thenameiscasesensitive
withamaximumnumberof44characters.Ifspacesareused,thenamemustbeenclosedin
quotes.
ThevalidrangefortheMIBindexis165536.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45217

6TANV57CLI-35A

2-1465

Total Access/NetVanta Carrier CLI Dictionary

ccm-enabled
UsetheccmenabledcommandtoenabletransmissionofCCMsbyallMEPsconfiguredin
thisMaintenanceDomain.UsethenoformofthecommandtodisabletheMEPsfromtrans
mittingCCMs.Whendisabled,aMEPceasestosendCCMframesbutcontinuestoprocess
receivedCCMs.

Usage Examples
Thefollowingisanexampleofhowtousetheccmenabledcommand.
(config-ecfm-domain MD_1)#ccm-enabled
(config-ecfm-domain MD_1)#

Functional Notes
TheccmenabledcommandisexecutedimmediatelytomodifythesettingofeveryMEP
currentlybelongingtothedomain.Itisnotstoredaspartoftheconfigurationofthedomain,
therefore,ithasnoeffectonanyMEPsthatmightbeaddedlater.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45201

2-1466

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Domain Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45197

6TANV57CLI-35A

2-1467

Total Access/NetVanta Carrier CLI Dictionary

mep-shutdown
UsethemepshutdowncommandtosettheadministrationstateofallmemberMEPsto
disabled,causingallMEPfunctionalitytohalt.Usethenoformofthiscommandtosetthe
statetoenabled.

Usage Examples
Thefollowingisanexampleofhowtousethemepshutdowncommand.
! To disable all member MEPs:
(config-ecfm-domain MD_1)#mep-shutdown
(config-ecfm-domain MD_1)#
! To enable all member MEPs:
(config-ecfm-domain MD_1)#no mep-shutdown
(config-ecfm-domain MD_1)#

Functional Notes
ThemepshutdowncommandisexecutedimmediatelytomodifythesettingofeveryMEP
currentlybelongingtothedomain.Itisnotstoredaspartoftheconfigurationofthedomain,
therefore,ithasnoeffectonanyMEPsthatmightbeaddedlater.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45199

2-1468

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Domain Configuration Command Set

mip-allowed [any|any-with-mep|none]
Usethemipallowed[any|anywithmep|none]commandtoconfiguretheMIPcreaterule
forallMaintenanceAssociationComponentswhosemipallowedvalueissettodefer.The
noversionofthiscommandsetsittothedefaultvalueofnone.

Syntax Description
any

MHFscanbecreatedonthisVIDonanyBridgePort

anywithmep

MHFscanbecreatedonthisVIDonanyBridgePortwithMEPat
lowerMDlevel

none

NoMHFscanbecreatedfortheVID

Usage Examples
Thefollowingisanexampleofhowtousethemipallowed[any|anywithmep|none]
command.
(config-ecfm-domain MD_1)#mip-allowed any
(config-ecfm-domain MD_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
88822

6TANV57CLI-35A

2-1469

Total Access/NetVanta Carrier CLI Dictionary

mp-sender-id [chassis-id|management-address|none]
Usethempsenderid[chassisid|managementaddress|none]commandtoenablethesender
IDTLVforpacketsthatbelongtoMEPsassignedtoassociationsinthisdomain.Thissettingis
usedwhenaMEPsparentassociationcomponentmpsenderidvalueissettodefer.Usethe
noformofthiscommandtosetitbacktothedefaultsettingofnone.

Syntax Description
chassisid

SendchassisidinthesenderIDTLV

managementaddress

SendmanagementaddressinthesenderIDTLV

none

DonotsendthesenderIDTLV

Usage Examples
Thefollowingisanexampleofhowtousethempsenderid[chassisid|management
address|none]command.
(config-ecfm-domain MD_1)#mp-sender-id chassis-id
(config-ecfm-domain MD_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45203

2-1470

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM Domain Configuration Command Set

mp-sender-id chassis-id management-address


UsethempsenderidchassisidmanagementaddresscommandtosendboththechassisID
andmanagementaddressinthesenderIDTLV.ThissettingisusedwhenaMEPsparent
associationcomponentmpsenderidvalueissettodefer.Usethenoformofthiscommandto
setitbacktothedefaultsettingofnone.

Usage Examples
Thefollowingisanexampleofhowtousethempsenderidchassisidmanagementaddress
command.
(config-ecfm-domain MD_1)#mp-sender-id chassis-id management-address
(config-ecfm-domain MD_1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45207

6TANV57CLI-35A

2-1471

Total Access/NetVanta Carrier CLI Dictionary

Ethernet OAM MEP Configuration Command Set


UsetheEthernetOAMMEPConfigurationCommandSettomodifyanIEEE802.1agConnec
tivityFaultManagementmaintenanceassociationendpoint.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface efm-group <shelf/slot/group>
ChassisId(config-efm-group name)#ethernet cfm mep * * * up
ChassisId(config-ecfm-mepx)#

ThefollowingisalistofcommandsavailableintheEthernetOAMMEPConfiguration
CommandSet.
alarmprioritylevel[errorccm|macstatus|none|rdiccm|remoteccm|xconccm]
alarmtimers<250010000><250010000>
ccmenabled
exit
linkstateawareness<18191>
linkstateawareness<18191>noccm
priority<07>
shutdown

2-1472

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM MEP Configuration Command Set

alarm-priority-level [errorccm|macstatus|none|rdiccm|remoteccm|xconccm]
Usethealarmprioritylevel[errorccm|macstatus|none|rdiccm|remoteccm|xconccm]
commandtosetthelowestlevelpriorityconditionthatcangenerateanalarmontheMEP.Use
thenoformofthiscommandtosettheleveltothedefault.

Syntax Description
errorccm

ErroredCCMReceived(level4)

macstatus

MACStatusErrorseeninrecivedCCM(level2)

none

GeneratenoalarmsonthisMEP

rdiccm

RemoteDefectIndicatorseeninreceivedCCM(level1lowest)

remoteccm

CCMsnotreceivedforatleast3.5CCMintervals(level3)

xconccm

CCMReceivedfromanunknownMAIDonaconfiguredmainte
nancelevel(level5highest)

Usage Examples
Thefollowingisanexampleofhowtousethealarmprioritylevel
[errorccm|macstatus|none|rdiccm|remoteccm|xconccm]command.
(config-eth-mep101)#alarm priority-level remoteccm
(config-eth-mep101)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45280

6TANV57CLI-35A

2-1473

Total Access/NetVanta Carrier CLI Dictionary

alarm-timers <2500-10000> <2500-10000>


Usethealarmtimers<250010000><250010000>commandtosetthealarmtimevalues.The
firstvalueenteredistheamountoftimeinmillisecondsadefectconditionmustexistbefore
beingreportedasanalarm.Thesecondvalueenteredistheamountoftimeinmilliseconds
thatadefectmustbeabsentbeforethealarmisreset.

Syntax Description
<250010000>

Entertime(inmilliseconds)thatadefectconditionmustbe
presentbeforebeingreported

Usage Examples
Thefollowingisanexampleofhowtousethealarmtimers<250010000><250010000>
command.
(config-eth-mep101)#alarm-timers 3000 5000
(config-eth-mep101)#

Functional Notes
Thevalidrangeforthealarmtimeandresettimeis250010000milliseconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45296

2-1474

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM MEP Configuration Command Set

ccm-enabled
UsetheccmenabledcommandtoenabletransmissionofCCMsbytheselectedMEP.When
disabled,aMEPceasestosendCCMframesbutcontinuestoprocessreceivedCCMs.ACCM
enabledmacrofunctionisprovidedatthemaintenancedomainandmaintenanceassociation
levelstosetthevalueonallmemberMEPswithineachscope.

Usage Examples
Thefollowingisanexampleofhowtousetheccmenabledcommand.
(config-eth-mep101)#ccm-enabled
(config-eth-mep101)#

Functional Notes
Thisccmenabledparameterislocallystoredaspartoftherunningconfiguration,unlikethe
ccmenabledfunctionsfoundintheEthernetOAMDomainConfigurationCommandSetand
theEthernetOAMAssociationConfigurationCommandSet.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45274

6TANV57CLI-35A

2-1475

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45270

2-1476

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM MEP Configuration Command Set

link-state-awareness <1-8191>
Usethelinkstateawareness<18191>toindicatetheremotepeertomonitor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
89505

6TANV57CLI-35A

2-1477

Total Access/NetVanta Carrier CLI Dictionary

link-state-awareness <1-8191> no-ccm


Usethelinkstateawareness<18191>noccmtosuppressCCMtransmissiontoindicatelink
failure

Syntax Description
<18191>

EnterPeerMEPID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
89506

2-1478

6TANV57CLI-35A

Section 2, Commands - Ethernet OAM MEP Configuration Command Set

priority <0-7>
Usethepriority<07>commandtosetthepriorityfortheselectedinterface.Usethenoform
tosetittothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethepriority<07>command.
(config-eth-mep101)#priority 7
(config-eth-mep101)#

Functional Notes
ThevalidrangeforthePbitvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45277

6TANV57CLI-35A

2-1479

Total Access/NetVanta Carrier CLI Dictionary

shutdown
UsetheshutdowncommandtosettheadministrationstateoftheMEPtodisabled,causingall
MEPfunctionalitytohalt.Usethenoformofthiscommandtosetthestatetoenabled.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable all member MEPs:
(config-eth-mep101)#shutdown
(config-eth-mep101)#
! To enable all member MEPs:
(config-eth-mep101)#no shutdown
(config-eth-mep101)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
119427

2-1480

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

EVC Configuration Command Set


UsetheEVCInterfaceConfigurationCommandSettoconfigureanEthernetVirtual
ConnectionasdefinedbyMEF6.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#evc WORD
ChassisId(config-evc name)#

ThefollowingisalistofcommandsavailableintheEVCConfigurationCommandSet.
connectmenport[defaultethernet|legacypppgroup]
connectmenportefmgroup[<shelf/slot/group>|WORD]
connectmenportethernet<shelf/slot/port>
connectmenportgigabitethernet<shelf/slot/port>
connectmenportlaggroup<shelf/slot/group>
connectmenporttengigabitethernet<shelf/slot/port>
doubletagswitched
exit
macswitched
preservecevlan
shutdown
stag<14094>
subscriberigmppriority<07>

6TANV57CLI-35A

2-1481

Total Access/NetVanta Carrier CLI Dictionary

connect men-port [default-ethernet|legacy-ppp-group]


UsetheconnectmenportcommandtoconfigurewhichporttheEVCisappliedto.Usetheno
formofthiscommandtoremoveaportasthemenport.

Syntax Description
defaultethernet

AdddefaultEthernetinterface

legacypppgroup

Specifiedgroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
40865

2-1482

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

connect men-port efm-group [<shelf/slot/group>|WORD]


Usetheconnectmenportefmgroup<shelf/slot/group>commandtoconfigurewhichEFM
grouptheselectedEVCisappliedto.UsethenoformofthiscommandtoremoveanEFM
groupastheMENport.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportefmgroup[<shelf/slot/
group>|WORD]command.
(config-evc EVC1)#connect men-port efm-group 1/0/1
(config-evc EVC1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

Command ID
40871

6TANV57CLI-35A

2-1483

Total Access/NetVanta Carrier CLI Dictionary

connect men-port ethernet <shelf/slot/port>


Usetheconnectmenportethernet<shelf/slot/port>commandtoconfigurewhichEthernet
interfacetheselectedEVCisappliedto.Usethenoformofthiscommandtoremovean
EthernetinterfaceastheMENport.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportethernet<shelf/slot/port>
command.
(config-evc EVC1)#connect men-port ethernet 1/0/1
(config-evc EVC1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
78108

2-1484

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

connect men-port gigabit-ethernet <shelf/slot/port>


Usetheconnectmenportgigabitethernet<shelf/slot/port>commandtoconfigurewhich
gigabitethernetinterfacetheselectedEVCisappliedto.Usethenoformofthiscommandto
removeagigabitethernetinterfaceastheMENport.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportgigabitethernet<shelf/slot/
port>command.
(config-evc EVC1)#connect men-port gigabit-ethernet 1/0/1
(config-evc EVC1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40869

6TANV57CLI-35A

2-1485

Total Access/NetVanta Carrier CLI Dictionary

connect men-port lag-group <shelf/slot/group>


Usetheconnectmenportlaggroup<shelf/slot/group>commandtoconfigurewhichlag
grouptheselectedEVCisappliedto.Usethenoformofthiscommandtoremovealaggroup
astheMENport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83127

2-1486

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

connect men-port ten-gigabit-ethernet <shelf/slot/port>


Functional Notes
SpecifythemenportasarootoftheEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
64474

6TANV57CLI-35A

2-1487

Total Access/NetVanta Carrier CLI Dictionary

double-tag-switched
UsethedoubletagswitchedcommandtoenabledoubletagswitchingonanEVC.

Usage Examples
Thefollowingisanexampleofhowtousethedoubletagswitchedcommand.
(config-evc 110)#mac-switched
(config-evc 110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187025G2),SM10GE(1187030G1)

Command ID
127588

2-1488

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40861

6TANV57CLI-35A

2-1489

Total Access/NetVanta Carrier CLI Dictionary

mac-switched
UsethemacswitchedcommandtoenablemacswitchingonanEVC.

Usage Examples
Thefollowingisanexampleofhowtousethemacswitchedcommand.
(config-evc 110)#mac-switched
(config-evc 110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187025G2),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
90198

2-1490

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

preserve-ce-vlan
UsethepreservecevlancommandtoconfiguretheunittopreservetheCEVLANintheEVC
aspayload.UsethenoformofthiscommandtoconfiguretheunittostriptheCEVLANtag
asitismappedtotheEVCinthecustomertonetworkdirectionandaddthecorrectCE
VLANtaginthenetworktocustomerdirection.IfCEVLANpreservationisdisabled,then
onlyoneCEVLANcanbemappedperEVC.

Usage Examples
Thefollowingisanexampleofhowtousethepreservecevlancommand.
(config-evc 110)#preserve-ce-vlan
(config-evc 110)#

Functional Notes
Ifpreservecevlanisenabledandctaghasavalue,thenthevalueisonlyusedtoclassify
trafficinthedownstreamdirection.Upstreamtraffichasthesamectagasthecevlan.
Ifpreservecevlanisenabledandthectagisnotset,thenthectagisnotusedtoclassify
downstreamtraffic.Upstreamtraffichasthesamectagasthecevlan.
Ifpreservecevlanisdisabledandthectagisset,thendownstreamtrafficisclassifiedbythe
stagandctag.UpstreamtheCEVLANisstrippedandtheprovisionedctagisaddedtothe
frame.
Ifpreservecevlanisdisabledandthectagisnotset,thendownstreamtrafficisclassifiedby
thestag.Upstreamtrafficonlyhasanstag.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40859

6TANV57CLI-35A

2-1491

Total Access/NetVanta Carrier CLI Dictionary

shutdown
UsetheshutdowncommandtoadministrativelydisabletheEVC.Usethenoformofthis
commandtoenabletheEVC.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the EVC:
(config-evc EVC1)#shutdown
(config-evc EVC1)#
! To enable the EVC:
(config-evc EVC1)#no shutdown
(config-evc EVC1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40860

2-1492

6TANV57CLI-35A

Section 2, Commands - EVC Configuration Command Set

s-tag <1-4094>
Usethestag<14094>commandtosettheVIDoftheVLANtagthatisusedtomarktrafficin
theEVC.UsethenoformofthecommandtoremovethetagfromtheEVC.

Usage Examples
Thefollowingisanexampleofhowtousethestag<14094>command.
(config-evc EVC1)#s-tag 100
(config-evc EVC1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40863

6TANV57CLI-35A

2-1493

Total Access/NetVanta Carrier CLI Dictionary

subscriber igmp priority <0-7>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
101596

2-1494

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

EVC Map Configuration Command Set


UsetheEVCMapInterfaceConfigurationCommandSettoconfigureamapofcustomerdata
fromaUNItoanEVCasdefinedbyMEF10.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#evc-map * <shelf/slot>
ChassisId(config-evc-map name x/x)#

ThefollowingisalistofcommandsavailableintheEVCMapConfigurationCommandSet.
connectdiscard
connectevcWORD
connectiphostWORD[<shelf/slot>|<remoteindex>]
connectmevcWORD
connectuniatm<shelf/slot/port.sub>
connectuniefmgroup<shelf/slot/group>
connectuniefmport<shelf/slot/port>
connectuniethernet<shelf/slot/port>
connectuniframerelay<shelf/slot/group>dlci<16991>
connectunigigabitethernet[<shelf/slot/port>|<remoteindex>]
connectunimuxponderhighspeed<shelf/slot/port>
connectunimuxpondermidspeed<shelf/slot/port>
connectunipppgroup<shelf/slot/group>
descriptionLINE
encapsulation[auto|ethernet]
encapsulationpppoa[llc|vcmux]
exit
match[broadcast|l2cp|multicast|unicast|untagged]
matchcevlanid<04094>
matchcevlanpri<07>
matchdscp<063>
matchethertypeHHHH
matchsourcemacaddressxx:xx:xx:xx:xx:xx
matchsourcemacaddressxx:xx:xx:xx:xx:xxxx:xx:xx:xx:xx:xx
menctag<14094>
menctagpri[<07>|inherit]
menpri[<07>|inherit]
menqueue[<07>|inherit]
shutdown
subscriberaccessdhcpmode[authenticate|block|transparent]
subscriberaccessdhcpoption82[loopcharacteristics|remoteid]

6TANV57CLI-35A

2-1495

Total Access/NetVanta Carrier CLI Dictionary

subscriberaccessdhcpoption82circuitidWORD
subscriberaccessmacfilterdestinationupstream[allowall|gatewayonly]
subscriberaccesspppoeintermediateagent[loopcharacteristics|remoteid]
subscriberaccesspppoeintermediateagentcircuitidWORD
subscriberaccesspppoemode[authenticate|block|transparent]
subscriberaccessstaticipA.B.C.D
subscriberaccessstaticipA.B.C.Dxx:xx:xx:xx:xx:xx
subscriberaccessstaticipA.B.C.Dxx:xx:xx:xx:xx:xxA.B.C.D
subscriberaccessstaticipA.B.C.Dxx:xx:xx:xx:xx:xxA.B.C.Dxx:xx:xx:xx:xx:xx
subscriberarpmode[block|proxy|transparent]
subscriberigmpimmediateleave
subscriberigmpmaxmulticastbandwidth<0n>
subscriberigmpmaxmulticastgroups<0n>
subscriberigmpmode[block|processingenabled|transparent]
subscriberigmpproxyrouteripaddressA.B.C.D

2-1496

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect discard
Usetheconnectdiscardcommandtoconfigurethemaptodiscardalltrafficlistedascriteria.
Usethenoformofthiscommandtoconfigurethemaptonotdiscardtraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectdiscardcommand.
(config-evc-map myMap)#connect discard
(config-evc-map myMap)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
40881

6TANV57CLI-35A

2-1497

Total Access/NetVanta Carrier CLI Dictionary

connect evc WORD


UsetheconnectevcWORD[leaf|root]commandtoconnecttheselectedEVCmaptoan
existingEVC.Thiscommandcreatesalogicalconnectionbetweenthecustomermapspecified
trafficandtheEVCthroughwhichthetrafficissenttothenetwork.Usethenoformofthis
commandtodisconnecttheEVCfromthemap.

Usage Examples
ThefollowingisanexampleofhowtousetheconnectevcWORDcommand.
(config-evc-map MAP1)#connect evc EVC1
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
40880

2-1498

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect ip-host WORD [<shelf/slot>|<remote-index>]


Syntax Description
WORD

NameofIPHost

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
120300

6TANV57CLI-35A

2-1499

Total Access/NetVanta Carrier CLI Dictionary

connect mevc WORD


Functional Notes
UsetheconnectmevcWORD[leaf

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135974

2-1500

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect uni atm <shelf/slot/port.sub>


Usetheconnectuniatm<shelf/slot/port.sub>commandtoconfiguretheUNIinterfacefrom
whichtrafficismapped.AUNIinterfacemustbedefinedforthemaptobeinarunningstate.
UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIforthe
selectedmap.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectuniatm<shelf/slot/port.sub>
command.
(config-evc-map MAP110)#connect uni atm 1/9/1.1
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
63300

6TANV57CLI-35A

2-1501

Total Access/NetVanta Carrier CLI Dictionary

connect uni efm-group <shelf/slot/group>


Usetheconnectuniefmgroup<shelf/slot/group>commandtoconfiguretheUNIinterface
fromwhichtrafficismapped.AUNIinterfacemustbedefinedtohavethemapinarunning
state.UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIfor
theselectedmap.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectuniefmgroup<shelf/slot/group>
command.
(config-evc-map MAP1)#connect uni efm-group 1/0/1
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
40878

2-1502

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect uni efm-port <shelf/slot/port>


Usetheconnectuniefmport<shelf/slot/port>commandtoconfiguretheUNIinterfacefrom
whichtrafficismapped.AUNIinterfacemustbedefinedforthemaptobeinarunningstate.
UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIforthe
selectedmap.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectuniefmport<shelf/slot/port>
command.
(config-evc-map MAP110)#connect uni efm-port 1/9/1
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
41287

6TANV57CLI-35A

2-1503

Total Access/NetVanta Carrier CLI Dictionary

connect uni ethernet <shelf/slot/port>


Usetheconnectuniethernet<shelf/slot/port>commandtoconfiguretheUNIinterfacefrom
whichtrafficismapped.AUNIinterfacemustbedefinedtohavethemapinarunningstate.
UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIforthe
selectedmap.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectuniethernet<shelf/slot/port>
command.
(config-evc-map MAP1)#connect uni ethernet 1/0/1
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
40874

2-1504

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect uni frame-relay <shelf/slot/group> dlci <16-991>


Usetheconnectuniframerelay<shelf/slot/group>commandtoconfiguretheUNIinterface
fromwhichtrafficismapped.AUNIinterfacemustbedefinedtohavethemapinarunning
state.UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIfor
theselectedmap.

Syntax Description
<shelf/slot/group>

Specifiedinterfacebygroupnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
142671

6TANV57CLI-35A

2-1505

Total Access/NetVanta Carrier CLI Dictionary

connect uni gigabit-ethernet [<shelf/slot/port>|<remoteindex>]


Usetheconnectunigigabitethernet<shelf/slot/port>commandtoconfiguretheUNIinterface
fromwhichtrafficismapped.AUNIinterfacemustbedefinedtohavethemapinarunning
state.UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIfor
theselectedmap.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectunigigabitethernet[<shelf/slot/
port>|<remoteindex>]command.
(config-evc-map MAP1)#connect uni gigabit-ethernet 1/0/1
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),TA3002POTS2GE(1187602G2),TA3242POTS4GE
(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40876

2-1506

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect uni muxponder-highspeed <shelf/slot/port>


Functional Notes
Usetheconnectunimuxponderhighspeed<shelf/slot/port>commandtoconfiguretheUNI
interfacefromwhichtrafficismapped.?AUNIinterfacemustbedefinedtohavethemapina
runningstate.Usethenoformofthiscommandtoremovetheinterfacefromservingasthe
UNIfortheselectedmap.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135970

6TANV57CLI-35A

2-1507

Total Access/NetVanta Carrier CLI Dictionary

connect uni muxponder-midspeed <shelf/slot/port>


Functional Notes
Usetheconnectunimuxpondermidspeed<shelf/slot/port>commandtoconfiguretheUNI
interfacefromwhichtrafficismapped.?AUNIinterfacemustbedefinedtohavethemapina
runningstate.Usethenoformofthiscommandtoremovetheinterfacefromservingasthe
UNIfortheselectedmap.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135968

2-1508

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

connect uni ppp-group <shelf/slot/group>


Usetheconnectunipppgroup<shelf/slot/group>commandtoconfiguretheUNIinterface
fromwhichtrafficismapped.AUNIinterfacemustbedefinedtohavethemapinarunning
state.UsethenoformofthiscommandtoremovetheinterfacefromservingastheUNIfor
theselectedmap.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89376

6TANV57CLI-35A

2-1509

Total Access/NetVanta Carrier CLI Dictionary

description LINE
UsethedescriptionLINEcommandtoaddatextdescriptiontotheEVCmap.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-evc-map MAP110)#description "port 1"
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1CEM32PortAM
(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),10GEthernet
Muxponder(1174101F1)

Command ID
88201

2-1510

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

encapsulation [auto|ethernet]
Usetheencapsulation[auto|ipoe|pppoe]commandtosettheencapsulationmodeforthe
EVCmap.

Syntax Description
auto

Encapsulationisautomaticallydetermined

ethernet

Ethernet

Functional Notes
ThedefaultencapsulationmodeisIPoE.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
41312

6TANV57CLI-35A

2-1511

Total Access/NetVanta Carrier CLI Dictionary

encapsulation pppoa [llc|vc-mux]


Usetheencapsulationpppoa[llc|vcmux]commandtoconfigurethePPPoAencapsulation.

Syntax Description
llc

LogicalLinkControl

vcmux

VirtualChannelMultiplexing

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2Splitter
AM(1187125L1),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
41315

2-1512

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Functional Notes
Theexitcommandhasnosubcommands.Theexitcommandhasnodefaultvalues.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40934

6TANV57CLI-35A

2-1513

Total Access/NetVanta Carrier CLI Dictionary

match [broadcast|l2cp|multicast|unicast|untagged]
Usethematchcommandtoconfiguretheingressmatchingcriteriaforthemap.Usetheno
formofthiscommandtoremovethematchingcriteriafromthemap.

Syntax Description
broadcast

Includebroadcasttrafficinmatchingcriteria

l2cp

IncludeLayer2ControlProtocolsinmatchingcriteria

multicast

Includemulticasttrafficinmatchingcriteria

unicast

Includeunicasttrafficinmatchingcriteria

untagged

Includeuntaggedtrafficinmatchingcriteria

Usage Examples
Thefollowingisanexampleofhowtousethematch
[broadcast|l2cp|multicast|unicast|untagged]command.
(config-evc-map MAP1)#match multicast
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),10GEthernetMuxponder(1174101F1),GPONAM
(1187501G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
42933

2-1514

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

match ce-vlan-id <0-4094>


Usethematchcevlanid<04094>commandtoconfiguretheingressmatchingcriteriato
includetheCEVLANidentifierforthemap.Usethenoformofthiscommandtoremovethe
matchingcriteriafromthemap.

Usage Examples
Thefollowingisanexampleofhowtousethematchcevlanid<04094>command.
(config-evc-map MAP1)#match ce-vlan-id 100
(config-evc-map MAP1)#

Functional Notes
ThevalidrangefortheVLANIDis0to4094.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40884

6TANV57CLI-35A

2-1515

Total Access/NetVanta Carrier CLI Dictionary

match ce-vlan-pri <0-7>


Usethematchcevlanpri<07>commandtoconfiguretheingressmatchingcriteriato
includetheprioritylevelwithintheCEVLANidentifierorthemap.Usethenoformofthis
commandtoremovethematchingcriteriafromthemap.

Usage Examples
Thefollowingisanexampleofhowtousethematchcevlanpri<07>command.
(config-evc-map MAP1)#match ce-vlan-pri 3
(config-evc-map MAP1)#

Functional Notes
ThevalidrangeforthePbitvalueis0to7.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
40886

2-1516

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

match dscp <0-63>


Usethematchdscp<063>commandtoconfiguretheingressmatchingcriteriatoincludea
DifferentiatedServicesCodePoint(DSCP)forthemap.Usethenoformofthiscommandto
removethematchingcriteriafromthemap.

Usage Examples
Thefollowingisanexampleofhowtousethematchdscp<063>command.
(config-evc-map MAP1)#match dscp 17
(config-evc-map MAP1)#

Functional Notes
Thevalidrangeforthecodepointis0to63.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40888

6TANV57CLI-35A

2-1517

Total Access/NetVanta Carrier CLI Dictionary

match ethertype HHHH


Usethematchethertypexxxxcommandtoconfiguretheingressmatchingcriteriatoinclude
anEthernetTypeforthemap.Usethenoformofthiscommandtoremovethematching
criteriafromthemap.

Usage Examples
ThefollowingisanexampleofhowtousethematchethertypeHHHHcommand.
(config-evc-map MAP1)#match dscp 17
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
95486

2-1518

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

match source mac-address xx:xx:xx:xx:xx:xx


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1)

Command ID
133186

6TANV57CLI-35A

2-1519

Total Access/NetVanta Carrier CLI Dictionary

match source mac-address xx:xx:xx:xx:xx:xx xx:xx:xx:xx:xx:xx


Syntax Description
xx:xx:xx:xx:xx:xx

MACaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1)

Command ID
133187

2-1520

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

men-c-tag <1-4094>
Usethemenctag<14094>commandtosetthesecondtag(orcustomertag)onupstream
traffic.Usenomenctagtoremovethemenctag.

Usage Examples
Thefollowingisanexampleofhowtousethemenctag<14094>command.
(config-evc 110)#c-tag 210
(config-evc 110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
100121

6TANV57CLI-35A

2-1521

Total Access/NetVanta Carrier CLI Dictionary

men-c-tag-pri [<0-7>|inherit]
Usethemenpri[<07>|inherit]commandtoconfigurethepriorityleveloftheMENCTagfor
theassociatedmap.WhenmapsareconfiguredforexplicitCoS,thePbitvalueoftheMENC
TagforassociatedframescanalwaysbesettothatCoSvalue.

Syntax Description
<07>

Pbitvalue

inherit

Usethepriorityoftheingresstraffic

Usage Examples
Thefollowingisanexampleofhowtousethemenctagpri[<07>|inherit]command.
(config-evc-map MAP1)#men-pri 5
(config-evc-map MAP1)#

Functional Notes
Usethe<07>inputtospecifytheprioritylevelofthethemenctag.Thisvaluecanonlybe
enteredasasinglenumberrepresentingoneoftheeightprioritylevels.
Usetheinheritoptiontoconfigurethemenctagtoinheritprioritylevelsfromthepriority
levelsoftheincomingCEVLANframesthatmatchthecriteriaoftheassociatedmap.
Bydefault,theMENCTagpriorityissettoinherit.TheMENCTagpriorityhasnoeffectifa
MENCTagisnotspecified.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
100892

2-1522

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

men-pri [<0-7>|inherit]
Usethemenpri[<07>|inherit]commandtoconfiguretheprioritylevelofthecriteriaforthe
associatedmapintheEVCtowhichthemapisconnected.Whenmapsareconfiguredfor
explicitCoS,thePbitvalueoftheEVCtagforassociatedframescanalwaysbesettothatCoS
value.

Syntax Description
<07>

Pbitvalue

inherit

Usethepriorityoftheingresstraffic

Usage Examples
Thefollowingisanexampleofhowtousethemenpri[<07>|inherit]command.
(config-evc-map MAP1)#men-pri 5
(config-evc-map MAP1)#

Functional Notes
Usethe<07>inputtospecifytheprioritylevelofthecriteriafortheassociatedmapinthe
EVCtowhichthemapisconnected.Thisvaluecanonlybeenteredasasinglenumberrepre
sentingoneoftheeightprioritylevels.
UsetheinheritoptiontoconfiguretheEVCtoinheritprioritylevelsfromtheprioritylevelsof
theincomingCEVLANframesthatmatchthecriteriaoftheassociatedmap.
Bydefault,theMENpriorityissettoinherit.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1523

Total Access/NetVanta Carrier CLI Dictionary

Command ID
40894

2-1524

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

men-queue [<0-7>|inherit]
Usethemenqueue[<07>|inherit]commandtoconfigurethequeuetowhichthematched
datashouldbemapped.Usethenoformofthiscommandtosetthequeuetodefault.

Syntax Description
<07>

Queuenumber

inherit

InheritqueuefromMENpriorityandtranslationofQoSmap

Usage Examples
Thefollowingisanexampleofhowtousethemenqueue[<07>|inherit]command.
(config-evc-map MAP1)#men-queue 3
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

Command ID
40897

6TANV57CLI-35A

2-1525

Total Access/NetVanta Carrier CLI Dictionary

shutdown
UsetheshutdowncommandtoadministrativelydisabletheEVCmap.Usethenoformofthis
commandtoenabletheEVCmap.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the EVC map:
(config-evc-map MAP1)#shutdown
(config-evc-map MAP1)#
! To enable the EVC map:
(config-evc-map MAP1)#no shutdown
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),NV814(1200637G4),
NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40882

2-1526

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access dhcp mode [authenticate|block|transparent]


Syntax Description
authenticate

UseDHCPforsubscriberauthentication

block

DiscardDHCP

transparent

IgnoreDHCP

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100366

6TANV57CLI-35A

2-1527

Total Access/NetVanta Carrier CLI Dictionary

subscriber access dhcp option-82 [loopcharacteristics|remote-id]


Usetherelayagentdhcplayer2option82commandtoenableDHCPoption82.

Syntax Description
option82

EnableDHCPOption82

loopcharacteristics

Enabletheloopcharacteristicsreporting

remoteid

EnableTR101RemoteIdentifier

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberaccessdhcpoption82[loopcharac
teristics|remoteid]command.
(config-evc-map MAP110)#relay-agent dhcp-layer2 option-82
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101353

2-1528

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access dhcp option-82 circuit-id WORD


UsetherelayagentcircuitidformatWORDcommandtoenterthecircuitidentifierforthe
EVCmap.

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberaccessdhcpoption82circuitid
WORDcommand.
(config-evc-map MAP110)#relay-agent circuit-id-format "test id"
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101357

6TANV57CLI-35A

2-1529

Total Access/NetVanta Carrier CLI Dictionary

subscriber access mac-filter destination upstream [allowall|gateway-only]


Syntax Description
allowall

DonotfilterondestinationMACupstream

gatewayonly

AllowonlyframesmatchingtheauthenticatedgatewayMAC
addressupstream

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1)

Command ID
147590

2-1530

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access pppoe intermediate-agent [loopcharacteristics|remote-id]


Usetherelayagentpppoeintermediateagentcommandtoenabletheintermediateagentfor
PPPoE.

Syntax Description
intermediateagent

EnablePPPoEintermediateagent

loopcharacteristics

Enabletheloopcharacteristicsreporting

remoteid

EnableTR101RemoteIdentifier

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberaccesspppoeintermediateagent
[loopcharacteristics|remoteid]command.
(config-evc-map MAP110)#relay-agent pppoe intermediate-agent
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101359

6TANV57CLI-35A

2-1531

Total Access/NetVanta Carrier CLI Dictionary

subscriber access pppoe intermediate-agent circuit-id WORD


UsetherelayagentcircuitidformatWORDcommandtoenterthecircuitidentifierforthe
EVCmap.

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberaccesspppoeintermediateagent
circuitidWORDcommand.
(config-evc-map MAP110)#relay-agent circuit-id-format "test id"
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101363

2-1532

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access pppoe mode


[authenticate|block|transparent]
SettheprocessingmodeforPPPoEdiscoverytraffic.

Syntax Description
authenticate

UsePPPoEforsubscriberauthentication

block

DiscardPPPoEDiscoveryTraffic

transparent

IgnorePPPoEdiscoverytraffic

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberaccesspppoemode[authen
ticate|block|transparent]command.
(config-evc-map MAP110)#relay-agent pppoe intermediate-agent
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100881

6TANV57CLI-35A

2-1533

Total Access/NetVanta Carrier CLI Dictionary

subscriber access static-ip A.B.C.D


Usethematchmacaddressxx:xx:xx:xx:xx:xxA.B.C.DcommandtoconfigureastaticIP
addressfortheEVCmap.

Usage Examples
ThefollowingisanexampleofhowtousethesubscriberaccessstaticipA.B.C.Dcommand.
(config-evc-map MAP110)#match mac-address 12:34:56:78:9a:bc 100.200.3.4
(config-evc-map MAP110)#

Functional Notes
AgatewayMACorIPaddressisnotrequired.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100912

2-1534

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx


Syntax Description
A.B.C.D

SubscriberIPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100911

6TANV57CLI-35A

2-1535

Total Access/NetVanta Carrier CLI Dictionary

subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx A.B.C.D


Usethematchmacaddressxx:xx:xx:xx:xx:xxA.B.C.Dxx:xx:xx:xx:xx:xxA.B.C.Dcommandto
configureagatewayIPaddressassociatedwithastaticMAC/IPaddressfortheEVCmap.

Syntax Description
A.B.C.D

SubscriberIPaddress

xx:xx:xx:xx:xx:xx

SubscriberMACaddressuse00:00:00:00:00:00toreleasea
lockedMAC

Usage Examples
ThefollowingisanexampleofhowtousethesubscriberaccessstaticipA.B.C.D
xx:xx:xx:xx:xx:xxA.B.C.Dcommand.
(config-evc-map MAP110)#match mac-address 12:34:56:78:9a:bc 100.200.3.4
ae:3d:42:ff:23:12 192.168.1.1
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100914

2-1536

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber access static-ip A.B.C.D xx:xx:xx:xx:xx:xx A.B.C.D


xx:xx:xx:xx:xx:xx
Usethematchmacaddressxx:xx:xx:xx:xx:xxA.B.C.Dxx:xx:xx:xx:xx:xxcommandto
configureagatewayMACaddressassociatedwithastaticMAC/IPaddressfortheEVCmap.

Syntax Description
A.B.C.D

SubscriberIPaddress

xx:xx:xx:xx:xx:xx

SubscriberMACaddressuse00:00:00:00:00:00toreleasea
lockedMAC

A.B.C.D

GatewayIPaddress

Usage Examples
ThefollowingisanexampleofhowtousethesubscriberaccessstaticipA.B.C.D
xx:xx:xx:xx:xx:xxA.B.C.Dxx:xx:xx:xx:xx:xxcommand.
(config-evc-map MAP110)#match mac-address 12:34:56:78:9a:bc 100.200.3.4
ae:3d:42:ff:23:12
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
100913

6TANV57CLI-35A

2-1537

Total Access/NetVanta Carrier CLI Dictionary

subscriber arp mode [block|proxy|transparent]


Syntax Description
block

DiscardARP

proxy

ProxyforsubscriberARP

transparent

IgnoreARP

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101378

2-1538

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber igmp immediate-leave


Useipigmpimmediateleavecommandtoenablesmartimmediateleave.Whenenabled,
transmissionofamulticaststreamisstoppedassoonasthelasthostleavesthemulticast
group.Whendisabled,transmissionofamulticaststreamisstoppedafteratimeoutofaquery
thatchecksifanyhostisstillinterestedinthemulticastgroup.

Usage Examples
Thefollowingisanexampleofhowtousethesubscriberigmpimmediateleavecommand.
(config-evc-map MAP1)#ip igmp immediate-leave
(config-evc-map MAP1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101633

6TANV57CLI-35A

2-1539

Total Access/NetVanta Carrier CLI Dictionary

subscriber igmp max-multicast bandwidth <0-n>


Usetheipigmpmaxmulticastbandwidth<0n>commandtospecifythemaximumallowed
multicastbandwidth.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101610

2-1540

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber igmp max-multicast groups <0-n>


Usetheipigmpmaxmulticastgroupscommandtospecifythemaximumallowedmulticast
groups.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101612

6TANV57CLI-35A

2-1541

Total Access/NetVanta Carrier CLI Dictionary

subscriber igmp mode [block|processing-enabled|transparent]


Syntax Description
block

DiscardallIGMPmessages

processingenabled

ProcessIGMPmessagesbasedonproxysettings

transparent

PassIGMPmessagestransparently

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101602

2-1542

6TANV57CLI-35A

Section 2, Commands - EVC Map Configuration Command Set

subscriber igmp proxy router ip address A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1)

Command ID
101625

6TANV57CLI-35A

2-1543

Total Access/NetVanta Carrier CLI Dictionary

Event Log Configuration Command Set


UsetheEventLogConfigurationcommandsettoconfiguresystemeventlogparameters.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#event-log-export
ChassisId(config-event-log)#

ThefollowingisalistofcommandsavailableintheEventLogConfigurationCommandSet.
alarmenablesystemlog[failure|full]
exit
mode[capacity|scheduled]
prefix
prefixWORD
retries<02>
schedule<HH:MM>
schedule<HH:MM>every<190>
suffixWORD
updateonly

2-1544

6TANV57CLI-35A

Section 2, Commands - Event Log Configuration Command Set

alarm enable system-log [failure|full]


UsethealarmenablesystemlogcommandstoenableSystemEventLogalarms.

Syntax Description
failure

Systemlogfailure

full

Systemlogfull

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablesystemlog[failure|full]
command.
(config-event-log)#alarm enable system-log failure
(config-event-log)#
(config-event-log)#alarm enable system-log full
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86800

6TANV57CLI-35A

2-1545

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80687

2-1546

6TANV57CLI-35A

Section 2, Commands - Event Log Configuration Command Set

mode [capacity|scheduled]
UsethemodecommandconfigurewhentheSystemEventLogisexported.

Syntax Description
capacity

Autoexportwhenthesystemlogisatthespecfiedcapacity

scheduled

Autoexportperthescheduledtime

Usage Examples
Thefollowingisanexampleofhowtousethemode[capacity|scheduled]command.
(config-event-log)#mode scheduled
(config-event-log)#
(config-event-log)#mode capacity
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63445

6TANV57CLI-35A

2-1547

Total Access/NetVanta Carrier CLI Dictionary

prefix
Usetheprefixcommandtoselectthefileprefixofthesystemeventlogautosavefilename.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63458

2-1548

6TANV57CLI-35A

Section 2, Commands - Event Log Configuration Command Set

prefix WORD
UsetheprefixWORDcommandtoselectthefileprefixofthesystemeventlogautosavefile
name.Usethenoformtosetthefileprefixtothedefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousetheprefixWORDcommand.
(config-event-log)#prefix myeventlog
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66257

6TANV57CLI-35A

2-1549

Total Access/NetVanta Carrier CLI Dictionary

retries <0-2>
Usetheretries<02>commandtosetthenumbertimeasystemeventlogsavewillbe
attempted.Usethenoformtosetthenumberofretriestothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheretries<02>command.
(config-event-log)#retries 2
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63464

2-1550

6TANV57CLI-35A

Section 2, Commands - Event Log Configuration Command Set

schedule <HH:MM>
Usetheschedule<HH:MM>commandtosetthetimeofdaythatthesystemeventlogwillbe
exported.Usethenoformtosetthetimeofdaytothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheschedule<HH:MM>command.
(config-event-log)#schedule 12:00
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63443

6TANV57CLI-35A

2-1551

Total Access/NetVanta Carrier CLI Dictionary

schedule <HH:MM> every <1-90>


Usetheschedule<HH:MM>every<190>commandtosetthetimeofdaythatthesystem
eventlogwillbeexportedandthenumberofdaysbetweenexports.Usethenoformtosetthe
timeofdayandtheintervalbetweenexportstothedefaultsettings.

Syntax Description
<HH:MM>

Timeofday

Usage Examples
Thefollowingisanexampleofhowtousetheschedule<HH:MM>every<190>command.
(config-event-log)#schedule 12:00 every 90
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63455

2-1552

6TANV57CLI-35A

Section 2, Commands - Event Log Configuration Command Set

suffix WORD
UsethesuffixWORDcommandtoselectthefileextensionofthesystemeventlogautosave
filename.Usethenoformtosetthefileextensiontothedefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousethesuffixWORDcommand.
(config-event-log)#suffix evl
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66258

6TANV57CLI-35A

2-1553

Total Access/NetVanta Carrier CLI Dictionary

update-only
Usetheupdateonlycommandtopreventfileoverlapbetweensystemeventlogexports.Use
thenoformtodisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheupdateonlycommand.
(config-event-log)#update-only
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63451

2-1554

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

EZ-EFM Application Command Set


UsetheEZEFMApplicationCommandSettodynamicallycreateormodifyanEFMgroup.
ChassisId>enable
ChassisId#application
ChassisId(app)#ez-efm <shelf>
ChassisId(app-ez-efm shelf x)#

ThefollowingisalistofcommandsavailableintheEZEFMApplicationCommandSet.
createWORDlink[<slot/port>|<slot/port:chan>]
createWORDlink[<slot/port>|<slot/port:chan>]upstream<1250000>downstream<1
250000>activelinksminimum<1n>
deleteWORD
exit
modifyWORDlink[<slot/port>|<slot/port:chan>]
modifyWORDlink[<slot/port>|<slot/port:chan>]upstream<1250000>downstream<1
250000>activelinksminimum<1n>
modifyWORDnolink[<slot/port>|<slot/port:chan>]
modifyWORDnolink[<slot/port>|<slot/port:chan>]upstream<0250000>downstream
<0250000>activelinksminimum<1n>
modifyWORDupstream<1250000>downstream<1250000>activelinksminimum<1n>

6TANV57CLI-35A

2-1555

Total Access/NetVanta Carrier CLI Dictionary

create WORD link [<slot/port>|<slot/port:chan>]


Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
61879

2-1556

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

create WORD link [<slot/port>|<slot/port:chan>] upstream <1250000> downstream <1-250000> active-links-minimum <1n>
UsethecreateWORDlink<slot/port>upstream<0250000>downstream<0250000>active
linksminimum<1n>commandtocreateanEFMgroupontheselectedshelfusingtheEZ
Bridgeapplication.TheEZBridgeapplicationhelpsensurethatEFMgroupsareassignedto
bondingenginesinthemostefficientmanner.

Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

<slot/port>

Addphysicalports.Useadashforconsecutiveports.Eachentry
mustbeseparatedbyacomma.Ex:1/14,2/5,3/532

<slot/port:chan>

Addlogicalchannels.Useadashforconsecutivechannels.Each
entrymustbeseparatedbyacomma.Ex:1/1:14,2/2:3,3/3:428

<1250000>

Rateinkbps

<1250000>

Rateinkbps

Usage Examples
ThefollowingisanexampleofhowtousethecreateWORDlink[<slot/port>|<slot/
port:chan>]upstream<1250000>downstream<1250000>activelinksminimum<1n>
command.
(app-ez-efm 1)#create testGroup link 1/1-4,2/1-4 upstream 16000
downstream 16000 active-links-minimum 8
(app-ez-efm 1)#

Functional Notes
UsetheWORDinputtoenterthenameofthenewEFMgroup.
Usethe<slot/port>inputtocreatelinksonthespecifiedslotandport.
Usethe<0250000>inputstoassignthemaximumupstreamanddownstreamrates.Thevalid
rangefortherateis0to250000.
Usethe<1n>inputtodesignatetheminimumnumberofactivelinks.
TheusageexamplecreatesanEFMgroupwith8links,links1to4onbothslot1andslot2.
Theratecontroldefaultisenabledsoeachlinkissettoamaximumrateof2000kbps(16000/8)
andminimumof500kbps(2000/4).Therateiscalculatedbasedontheup/downstreamrate
forthegroupdividedbytheactivelinksminimum.ForaSHDSLcard,theactualrateper
SHDSLportis2048kbps,sinceitisroundeduptothenearest64kbps.Iftheratemodeforthe
SHDSLportisadaptive,thentheminimumrateissetto512kbps,whichisalsoroundedupto
thenearest64kbps.

Local Security Permissions


Admin,TechSupport

6TANV57CLI-35A

2-1557

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
61886

2-1558

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

delete WORD
UsethedeleteWORDcommandtodeletethespecifiedEFMgroupontheselectedshelf.

Usage Examples
ThefollowingisanexampleofhowtousethedeleteWORDcommand.
(app-ez-efm shelf x)#delete group1
(app-ez-efm shelf x)#

Functional Notes
UsetheWORDinputtoenterthenameoftheEFMgrouptodelete.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
61908

6TANV57CLI-35A

2-1559

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
61916

2-1560

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

modify WORD link [<slot/port>|<slot/port:chan>]


Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
64239

6TANV57CLI-35A

2-1561

Total Access/NetVanta Carrier CLI Dictionary

modify WORD link [<slot/port>|<slot/port:chan>] upstream <1250000> downstream <1-250000> active-links-minimum <1n>
UsethemodifyWORDlink<slot/port>upstream<0250000>downstream<0250000>active
linksminimum<1n>commandtoaddlinkstoanexistingEFMgroupontheselectedshelf.

Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

<slot/port>

Addphysicalports.Useadashforconsecutiveports.Eachentry
mustbeseparatedbyacomma.Ex:1/14,2/5,3/532

<slot/port:chan>

Addlogicalchannels.Useadashforconsecutivechannels.Each
entrymustbeseparatedbyacomma.Ex:1/1:14,2/2:3,3/3:428

<1250000>

Rateinkbps

<1250000>

Rateinkbps

Usage Examples
ThefollowingisanexampleofhowtousethemodifyWORDlink[<slot/port>|<slot/
port:chan>]upstream<1250000>downstream<1250000>activelinksminimum<1n>
command.
(app-ez-efm 1)#modify testGroup link 2/1-4 upstream 16000 downstream
16000 active-links-minimum 8
(app-ez-efm 1)#

Functional Notes
UsetheWORDinputtoenterthenameoftheexistingEFMgroup.
Usethe<slot/port>inputtoaddlinksonthespecifiedslotandport.
Usethe<0250000>inputstoassignthemaximumupstreamanddownstreamrates.Thevalid
rangefortherateis0to250000.
Usethe<1n>inputtodesignatetheminimumnumberofactivelinks.
TheusageexampleisanexampleofhowtomodifyanEFMgroup.Eachinputinthis
commandmustbeentered.Ifaninputisnotchanging,enterthecurrentvalueforthatinput.
AmessageisreturnediftheEZBridgeapplicationdeterminesthatthechangesrequire
movingtheEFMgrouptoanotherslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

2-1562

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64245

6TANV57CLI-35A

2-1563

Total Access/NetVanta Carrier CLI Dictionary

modify WORD no-link [<slot/port>|<slot/port:chan>]


Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
64247

2-1564

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

modify WORD no-link [<slot/port>|<slot/port:chan>] upstream


<0-250000> downstream <0-250000> active-links-minimum
<1-n>
UsethemodifyWORDnolink<slot/port>upstream<0250000>downstream<0250000>
activelinksminimum<1n>commandtoremovelinksfromanexistingEFMgrouponthe
selectedshelf.

Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

<slot/port>

Removephysicalports.Useadashforconsecutiveports.Each
entrymustbeseparatedbyacomma.Ex:1/14,2/5,3/532

<slot/port:chan>

Removelogicalchannels.Useadashforconsecutivechannels.
Eachentrymustbeseparatedbyacomma.Ex:1/1:14,2/2:3,3/3:4
28

<0250000>

Rateinkbps

<0250000>

Rateinkbps

Usage Examples
ThefollowingisanexampleofhowtousethemodifyWORDnolink[<slot/port>|<slot/
port:chan>]upstream<0250000>downstream<0250000>activelinksminimum<1n>
command.
(app-ez-efm 1)#modify testGroup no-link 2/1-4 upstream 16000 downstream
16000 active-links-minimum 8
(app-ez-efm 1)#

Functional Notes
UsetheWORDinputtoenterthenameoftheexistingEFMgroup.
Usethe<slot/port>inputtoaddlinksonthespecifiedslotandport.
Usethe<0250000>inputstoassignthemaximumupstreamanddownstreamrates.Thevalid
rangefortherateis0to250000.
Usethe<1n>inputtodesignatetheminimumnumberofactivelinks.
TheusageexampleisanexampleofhowtomodifyanEFMgroup.Inthisexample,EFMlinks
1to4onslot2areremovedfromthegroup.Eachinputinthiscommandmustbeentered.If
aninputisnotchanging,enterthecurrentvalueforthatinput.Amessageisreturnedifthe
EZBridgeapplicationdeterminesthatthechangesrequiremovingtheEFMgrouptoanother
slot.

Local Security Permissions


Admin,TechSupport

6TANV57CLI-35A

2-1565

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64253

2-1566

6TANV57CLI-35A

Section 2, Commands - EZ-EFM Application Command Set

modify WORD upstream <1-250000> downstream <1250000> active-links-minimum <1-n>


UsethemodifyWORDlink<slot/port>upstream<0250000>downstream<0250000>active
linksminimum<1n>commandtoaddlinkstoanexistingEFMgroupontheselectedshelf.

Syntax Description
WORD

AtextstringusedtoreferencethisEFMgroup

<1250000>

Rateinkbps

<1250000>

Rateinkbps

Usage Examples
ThefollowingisanexampleofhowtousethemodifyWORDupstream<1250000>
downstream<1250000>activelinksminimum<1n>command.
(app-ez-efm 1)#modify testGroup link 2/1-4 upstream 16000 downstream
16000 active-links-minimum 8
(app-ez-efm 1)#

Functional Notes
UsetheWORDinputtoenterthenameoftheexistingEFMgroup.
Usethe<slot/port>inputtoaddlinksonthespecifiedslotandport.
Usethe<0250000>inputstoassignthemaximumupstreamanddownstreamrates.Thevalid
rangefortherateis0to250000.
Usethe<1n>inputtodesignatetheminimumnumberofactivelinks.
TheusageexampleisanexampleofhowtomodifyanEFMgroup.Eachinputinthis
commandmustbeentered.Ifaninputisnotchanging,enterthecurrentvalueforthatinput.
AmessageisreturnediftheEZBridgeapplicationdeterminesthatthechangesrequire
movingtheEFMgrouptoanotherslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

6TANV57CLI-35A

2-1567

Total Access/NetVanta Carrier CLI Dictionary

Command ID
103373

2-1568

6TANV57CLI-35A

Section 2, Commands - Fan Configuration Command Set

Fan Configuration Command Set


Usethefanconfigurationcommandsettoconfigureparametersassociatedwithaparticular
faninthesystem.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#fan <shelf/slot>
ChassisId(config-fan x/x)#

ThefollowingisalistofcommandsavailableintheFanConfigurationCommandSet.
alarmenable[multiplefan|singlefan]
exit
speed[auto|max]

6TANV57CLI-35A

2-1569

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [multiple-fan|single-fan]


Usethealarmenablecommandtoenablethealarmsassociatedwiththefanmodule.Usethe
noformofthiscommandtodisablethespecifiedalarm.

Syntax Description
multiplefan

Multiplefanfailure

singlefan

Singlefanfailure

Usage Examples
Thefollowingisanexampleofhowtousethealarmenable[multiplefan|singlefan]
command.
(config)#fan 1/F
(config-fan 1/F)#alarm enable single-fan

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1)

Command ID
87684

2-1570

6TANV57CLI-35A

Section 2, Commands - Fan Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
TA500023inchFan(1187080L1),NV824(1200634G4),NV828(1200634G2),NV844
(1200635G2)

Command ID
87703

6TANV57CLI-35A

2-1571

Total Access/NetVanta Carrier CLI Dictionary

speed [auto|max]
Usethespeedcommandtospecifythespeedofthefan.IfAutoisspecifiedthefanspeedis
automaticallycontrolledbasedonthesystemsneed.IfMaxisspecifiedthefanspeedissetto
themaximumsetting.Usethenoformofthiscommandtorestorethedefaultsetting.

Syntax Description
auto

Fanspeedisautomatic

max

Fanspeedismaximum

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1)

Command ID
87688

2-1572

6TANV57CLI-35A

Section 2, Commands - Frame Relay Group Interface Configuration Command Set

Frame Relay Group Interface Configuration Command Set


UsetheFrameRelayGroupInterfaceConfigurationCommandSettoconfiguretheselected
ATMlinks.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface frame-relay <shelf/slot/group>
ChassisId(config-frame-relay x/x/x)#

ThefollowingisalistofcommandsavailableintheFrameRelayGroupInterfaceConfigu
rationCommandSet.
connectt1[<shelf/slot/port>|<shelf/slot/port:chan>]
connectt1[<shelf/slot/port>|<shelf/slot/port:chan>]timeslots<124>
exit
lmitype[ansi|none]
shutdown[maintenance|unassigned]

6TANV57CLI-35A

2-1573

Total Access/NetVanta Carrier CLI Dictionary

connect t1 [<shelf/slot/port>|<shelf/slot/port:chan>]
Functional Notes
Usetheconnect<shelf/slot/port>commandtoaddT1linkstoaframerelaygroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133671

2-1574

6TANV57CLI-35A

Section 2, Commands - Frame Relay Group Interface Configuration Command Set

connect t1 [<shelf/slot/port>|<shelf/slot/port:chan>] timeslots


<1-24>
Syntax Description
<shelf/slot/port>

Specifiedinterface

<shelf/slot/port:chan>

Specifiedinterface

Functional Notes
SpecifiestheDS0timeslots.InitiallyonlyasingleseriesofconsecutiveDS0smaybespecified.
Inputpatterncouldbesomethingsuchas:114

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133673

6TANV57CLI-35A

2-1575

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133677

2-1576

6TANV57CLI-35A

Section 2, Commands - Frame Relay Group Interface Configuration Command Set

lmi-type [ansi|none]
Syntax Description
ansi

ANSIT1.617aAnnexD1994

none

DisableLMIsignaling

Functional Notes
SelectstheLMIoperationfortheFrameRelaygrup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133674

6TANV57CLI-35A

2-1577

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Disableallalarmsforinterface(OutofServiceMaintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Functional Notes
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supportedusetheshutdownmaintenancecommandtoenabletheinterfacebutinhibitalarms.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133666

2-1578

6TANV57CLI-35A

Section 2, Commands - Frame Relay PVC Interface Configuration Command Set

Frame Relay PVC Interface Configuration Command Set


UsetheFrameRelayPVCInterfaceConfigurationCommandSettoconfiguretheselected
ATMlinks.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface frame-relay * dlci <16-991>
ChassisId(config-command)#

ThefollowingisalistofcommandsavailableintheFrameRelayPVCInterfaceConfiguration
CommandSet.
descriptionLINE
exit
inversearp
mtu<2621600>
peerdefaultipaddressA.B.C.D
peerdefaultipaddressA.B.C.DA.B.C.D
peerdefaultipdefaultgateway
peerdefaultipdefaultgatewayA.B.C.D
shutdown[maintenance|unassigned]

6TANV57CLI-35A

2-1579

Total Access/NetVanta Carrier CLI Dictionary

description LINE
Functional Notes
UsethedescriptionLINE?commandtoidentifythespecified?PVC.Usethenoformofthis
commandtoremoveadescription.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133690

2-1580

6TANV57CLI-35A

Section 2, Commands - Frame Relay PVC Interface Configuration Command Set

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133694

6TANV57CLI-35A

2-1581

Total Access/NetVanta Carrier CLI Dictionary

inverse-arp
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133695

2-1582

6TANV57CLI-35A

Section 2, Commands - Frame Relay PVC Interface Configuration Command Set

mtu <262-1600>
Functional Notes
2621600isthestandardrangebutsomeproductsmaysupportadifferentsubset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133697

6TANV57CLI-35A

2-1583

Total Access/NetVanta Carrier CLI Dictionary

peer default ip address A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133702

2-1584

6TANV57CLI-35A

Section 2, Commands - Frame Relay PVC Interface Configuration Command Set

peer default ip address A.B.C.D A.B.C.D


Syntax Description
A.B.C.D

PrimaryIPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133703

6TANV57CLI-35A

2-1585

Total Access/NetVanta Carrier CLI Dictionary

peer default ip default-gateway


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133704

2-1586

6TANV57CLI-35A

Section 2, Commands - Frame Relay PVC Interface Configuration Command Set

peer default ip default-gateway A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133705

6TANV57CLI-35A

2-1587

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Syntax Description
shutdown

DisablethisPVC(OutofServiceUnassigned)

maintenance

DisablethisPVC(OutofServiceMaintenance)

unassigned

DisablethisPVC(OutofServiceUnassigned)

Functional Notes
UsetheshutdowncommandtoadministrativelydisablethePVC(nodataispassedthrough).
UsethenoshutdowncommandtoenablethePVCandallowittopassdata.Ifsupporteduse
theshutdownmaintenancecommandtoenablethePVCbutinhibitalarms.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133691

2-1588

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

FXS Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface fxs <shelf/slot/port>
ChassisId(config-fxs x/x/x)#

ThefollowingisalistofcommandsavailableintheFXSInterfaceConfigurationCommand
Set.
alarmenable[lineshowering|trunkconditioning]
descriptionLINE
exit
impedance[600r|900c|auto|z1|z2|z3|z4|z5|z6|z7|z8]
ringvoltage<50,60,70,80>
shutdown[maintenance|unassigned]
signaling[groundstart|loopstart|tr08sp|tr08uvg]
test[battery|line|reversebattery|ringing|tipopen]
testtone[far|near]

6TANV57CLI-35A

2-1589

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [line-showering|trunk-conditioning]


Syntax Description
enable

Enableallinterfacealarms

lineshowering

Enablethelineshoweringalarm

trunkconditioning

Enablethetrunkconditioningalarm

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95666

2-1590

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedFXSinterface.Theidentification
iscustomercontrolledandmaintainedasaconfigurationitemfortheselectedFXSinterface.
Usethenoformofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-fxs 1/0/4)#description FXS Ring 4
(config-fxs 1/0/4)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95624

6TANV57CLI-35A

2-1591

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
97292

2-1592

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

impedance [600r|900c|auto|z1|z2|z3|z4|z5|z6|z7|z8]
Syntax Description
600r

600Ohms

900c

900+2.16uF

auto

Automaticallyselecttheimpedence

z1

220+(820||115nF)

z2

270+(750||150nF)

z3

270+(750||150nF),Zin=600

z4

320+(1050||230nF)

z5

350+(1000||210nF),Zin=600

z6

370+(620||310nF)

z7

800||(100+50nF),Zin=900+2.16uF

z8

1650||(100+5nF),Zin=900+2.16uF

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95639

6TANV57CLI-35A

2-1593

Total Access/NetVanta Carrier CLI Dictionary

ring-voltage <50,60,70,80>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1)

Command ID
95692

2-1594

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.Use
theshutdownmaintenancecommandtoenabletheinterfacebutinhibitalarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-fxs 1/1/1)#shutdown
(config-fxs 1/1/1)#
! To disable the interface:
(config-fxs 1/1/1)#shutdown unassigned
(config-fxs 1/1/1)#
! To enable the interface:
(config-fxs 1/1/1)#no shutdown
(config-fxs 1/1/1)#
! To enable the interface but inhibit alarms:
(config-fxs 1/1/1)#shutdown maintenance
(config-fxs 1/1/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE

6TANV57CLI-35A

2-1595

Total Access/NetVanta Carrier CLI Dictionary

(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95626

2-1596

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

signaling [ground-start|loop-start|tr08-sp|tr08-uvg]
Syntax Description
groundstart

Groundstartsignaling

loopstart

Loopstartsignaling

tr08sp

TR08SinglePartysignaling

tr08uvg

TR08UniversalVoiceGradesignaling

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95694

6TANV57CLI-35A

2-1597

Total Access/NetVanta Carrier CLI Dictionary

test [battery|line|reverse-battery|ringing|tip-open]
Syntax Description
battery

ProvideBattery

line

Measureimpedanceandforeignvoltagesontheline

reversebattery

ProvideReverseBattery

ringing

ProvideRinging(2son,4soffcadence)

tipopen

ProvideTipOpen

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95673

2-1598

6TANV57CLI-35A

Section 2, Commands - FXS Interface Configuration Command Set

test tone [far|near]


Syntax Description
far

Farside

near

Nearside

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95678

6TANV57CLI-35A

2-1599

Total Access/NetVanta Carrier CLI Dictionary

Gigabit-Ethernet Interface Configuration Command Set


UsetheGigabitEthernetInterfaceConfigurationCommandSettoconfigureGigabitEthernet
interfacesasdefinedbyIEEE802.3
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface muxponder-midspeed * gigabit-ethernet
ChassisId(config-muxpon-mid-giga-eth x/x/x)#

ThefollowingisalistofcommandsavailableintheGigabitEthernetInterfaceConfiguration
CommandSet.
alarmenable[downstreamfault|heartbeatloss|lacptimeout|linkdownenterprise|link
downrfc2863|portmode|upstreamnode]
alarmenablepluggable[fault|missing|speedmismatch|temperaturehigh|unknown]
alarmenableshutdownmaintenance
descriptionLINE
downlink
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORD[down|up]
ethernetoamenable
exit
fullduplex
halfduplex
lacpgrammarstandbyaggregation
lacpmode[active|passive]
linkstateawareness
macagingtime<03600>
maclimit[<1n>|disabled]
mtu<150010000>
shutdown[maintenance|unassigned]
speed[10|100|1000|2500|auto]
stagdei
subtendedhostezprovisioning
subtendedhostipaddressA.B.C.DA.B.C.D
subtendedhostipaddressdhcp
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|listener|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD
subtendedhostsnmpservercommunityreadwriteWORD

2-1600

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtendedhostsnmpserverezprovisioninghostA.B.C.Dtrapsversion[1|2c]
subtendedhostsnmpserverlocationWORD
subtendedhoststag[<14094>|inherit]
subtendedhoststagpriority<07>
thresholdsbroadcasts15minute<04294967295>
thresholdsbroadcasts24hour<04294967295>
thresholdsdiscards15minute<04294967295>
thresholdsdiscards24hour<04294967295>
thresholdserrors15minute<04294967295>
thresholdserrors24hour<04294967295>
thresholdsgiants15minute<04294967295>
thresholdsgiants24hour<04294967295>
thresholdsinvalidvlan15minute<04294967295>
thresholdsinvalidvlan24hour<04294967295>
thresholdslinkstateawarenessbandwidthminimum<02147483647>
thresholdslinkstateawarenesslinksminimum<0n>
thresholdsmulticasts15minute<04294967295>
thresholdsmulticasts24hour<04294967295>
thresholdspeakmacentries15minute<0n>
thresholdspeakmacentries24hour<0n>
thresholdsrunts15minute<04294967295>
thresholdsrunts24hour<04294967295>

6TANV57CLI-35A

2-1601

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [downstream-fault|heartbeat-loss|lacptimeout|link-down-enterprise|link-down-rfc2863|portmode|upstream-node]


Usethealarmenablecommandtoallowthelistedgigabitethernetinterfacealarmstobe
generatedwhentheerrorconditionsarepresent.

Syntax Description
downstreamfault

Downstreamnodeisinthenotreadystate

heartbeatloss

Treenetworkingheartbeatloss

lacptimeout

LACPtimeouthasoccured

linkdownenterprise

Enterpriselinkdownalarm

linkdownrfc2863

RFC2863linkdownalarm

portmode

Portmodedoesnotmatchconnecteddevice

upstreamnode

Upstreamnodecannotprocessprotectionmessages

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),QuadGigELM(1187551E1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1)

Command ID
78019

2-1602

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

alarm enable pluggable [fault|missing|speedmismatch|temperature-high|unknown]


Syntax Description
fault

Devicefault

missing

Missingdevice

speedmismatch

Speedcapabilitymismatch

temperaturehigh

Overtemperature

unknown

Unknowndevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
101980

6TANV57CLI-35A

2-1603

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
111846

2-1604

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedbackplaneinterface.Usetheno
formofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-gig-eth 1/0/2)#description Gig Eth Port #2
(config-gig-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78719

6TANV57CLI-35A

2-1605

Total Access/NetVanta Carrier CLI Dictionary

downlink
UsethedownlinkcommandtosetthisinterfaceasadownlinktoanotherTotalAccess5000or
OSPDSLAM.ThisisusedinmultinodeorHDXapplicationsforredundancyandtiming
purposes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
87730

2-1606

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64552

6TANV57CLI-35A

2-1607

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm enable


UsetheethernetcfmenablecommandtoenabletheethernetOAMconnectivityfault
managementsubsystemandallocateresources.Usethenoformofthiscommandtodisable
thesubsystem,causingallCFMfunctionstoceaseanddeallocateresources.Anyexisting
CFMconfigurationisretained,butnoframesaresentorreceivedandnoresourcesare
consumedotherthanspaceintheconfiguration.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmenablecommand.
! To enable the ethernet OAM connectivity fault management subsystem:
(config-gig-eth 1/0/1)#ethernet cfm
(config-gig-eth 1/0/1)#
! To disable the ethernet OAM connectivity fault management subsystem:
(config-gig-eth 1/0/1)#no ethernet cfm
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
120312

2-1608

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

ethernet cfm mep <1-8191> WORD WORD [down|up]


Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

down

Facingthephysicalport

up

Facingtheswitchingelement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
64557

6TANV57CLI-35A

2-1609

Total Access/NetVanta Carrier CLI Dictionary

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
120330

2-1610

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78800

6TANV57CLI-35A

2-1611

Total Access/NetVanta Carrier CLI Dictionary

full-duplex
UsethefullduplexcommandtoconfiguretheEthernetportforfullduplexoperation.
Thisallowstheporttosendandreceivesimultaneously.

Functional Notes
Thefullduplexcommandhasnosubcommands.Thedefaultvalueisautowhichissetusing
thespeedcommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV8044(1172804G1)

Command ID
66282

2-1612

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

half-duplex
UsethehalfduplexcommandtoconfiguretheEthernetportforhalfduplexoperation.
Thisallowstheporttoeithersendorreceiveatanygivenmoment,butnotsimultaneously.

Functional Notes
Thehalfduplexcommandhasnosubcommands.Thedefaultvalueisautowhichissetusing
thespeedcommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV8044(1172804G1)

Command ID
66281

6TANV57CLI-35A

2-1613

Total Access/NetVanta Carrier CLI Dictionary

lacp grammar standby-aggregation


Usethelacpgrammarstandbyaggregationcommandtospecifyhowastandbymodule
buildsLACPDUframes.Whenenabled,theaggregationbitisalwayssetonthestandby
moduleLACPDUs.Thesyncbitisusedtoindicatethattheactivemoduleisreadytoreceive
traffic.Whendisabled,theaggregationbitisusedtoindicatethatthestandbymoduleisready
toreceivetraffic.

Usage Examples
Thefollowingisanexampleofhowtousethelacpgrammarstandbyaggregationcommand.
(config-gig-eth 1/A/1)#lacp grammar standby-aggregation
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87692

2-1614

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

lacp mode [active|passive]


Usethelacpmode[active|passive]commandtosettheLinkAggregationControlProtocol
(LACP)participationfortheselectedinterface.

Syntax Description
active

Activenegotiatingstate

passive

Passivenegotiatingstate

Usage Examples
Thefollowingisanexampleofhowtousethelacpmode[active|passive]command.
(config-gig-eth 1/A/1)# lacp mode active
(config-gig-eth 1/A/1)#

Functional Notes
LACPallowsanetworkdevicetonegotiateanautomaticbundlingoflinksbysendingLACP
packetstothepeer(directlyconnecteddevicethatalsoimplementsLACP).LACPworksby
sendingframes(LACPDUs)downalllinksthathavetheprotocolenabled.Ifadeviceis
presentontheotherendofthelinkthatalsohasLACPenabled,itwillalsoindependently
sendframesalongthesamelinksenablingthetwounitstodetectmultiplelinksbetween
themselvesandthencombinethemintoasinglelogicallink.LACPcanbeconfiguredinone
oftwomodes:ActiveorPassive.InActivemodeitwillalwayssendframesalongthe
configuredlinks.InPassivemodehowever,itactsasspeakwhenspokento,andtherefore
canbeusedasawayofcontrollingaccidentalloops(aslongastheotherdeviceisinactive
mode).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
87332

6TANV57CLI-35A

2-1615

Total Access/NetVanta Carrier CLI Dictionary

link-state-awareness
UsethelinkstateawarenesscommandtoenablelinkstateawarenessfortheselectedGigabit
Ethernetport.ForEFMgroupbasedMENports,thelinkstateawarenessfeature,when
enabled,shutsdowntheGigabitEthernetportifalloftheMENportstowhichtrafficis
mappedbecomeunavailable.Usethenoformofthiscommandtodisablelinkstate
awareness.

Usage Examples
Thefollowingisanexampleofhowtousethelinkstateawarenesscommand.
(config-gig-eth 1/0/1)#link-state-awareness
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44773

2-1616

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

mac aging-time <0-3600>


Usethemacagingtime<03600>commandtoconfiguretheMACagingtimeinseconds.
Value0forceslearnandlock.Minvalueis5secondsandmax3600seconds.

Usage Examples
Thefollowingisanexampleofhowtousethemacagingtime<03600>command.
838_112(config-gig-eth 1/0/1)#mac aging-time 1000
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89690

6TANV57CLI-35A

2-1617

Total Access/NetVanta Carrier CLI Dictionary

mac limit [<1-n>|disabled]


Syntax Description
<1n>

NumberofMACaddresses

disabled

DisableMAClimitingonthisinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44759

2-1618

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

mtu <1500-10000>
Functional Notes
150010000isthestandardrange,butsomeproductsmaysupportasmallersubset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV8044(1172804G1)

Command ID
104778

6TANV57CLI-35A

2-1619

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.Ifsupported,usetheshutdownunassignedcommandtodisabletheinterface.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-gig-eth 1/0/1)#shutdown
(config-gig-eth 1/0/1)#
! To disable the interface:
(config-gig-eth 1/0/1)#shutdown unassigned
(config-gig-eth 1/0/1)#
! To enable the interface:
(config-gig-eth 1/0/1)#no shutdown
(config-gig-eth 1/0/1)#
! To enable the interface but inhibit alarms:
(config-gig-eth 1/0/1)#shutdown maintenance
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),TA3002POTS2GE(1187602G2),TA3242POTS4

2-1620

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78691

6TANV57CLI-35A

2-1621

Total Access/NetVanta Carrier CLI Dictionary

speed [10|100|1000|2500|auto]
UsethespeedcommandtoconfigurethespeedofanGigabitEthernetinterface.Usetheno
formofthiscommandtoreturntothedefaultvalue.

Syntax Description
10

Configurethegigabitethernetfor10Mbpsoperation

100

Configurethegigabitethernetfor100Mbpsoperation

1000

Configurethegigabitethernetfor1000Mbpsoperation

2500

Configurethegigabitethernetfor2500Mbpsoperation

auto

Enableautonegotiationofspeed

Usage Examples
Thefollowingisanexampleofhowtousethespeed[10|100|1000|2500|auto]command.
(config-gig-eth 1/0/1)#speed 100
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),FIBERAM(1187552G1),QuadGigELM
(1187550G2),QuadGigELM(1187551E1),ActiveEth24PortAM(1187560F1),SM2GE
(1187020G1),SM2GE(1187020G2),QuadGigELM(1187550E1),SM(1187020E1),SM
(1187020L1),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1622

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

Command ID
44751

6TANV57CLI-35A

2-1623

Total Access/NetVanta Carrier CLI Dictionary

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
95501

2-1624

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host ez-provisioning
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138293

6TANV57CLI-35A

2-1625

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip address A.B.C.D A.B.C.D


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipaddressA.B.C.DA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip address 192.168.0.2
255.255.255.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
104997

2-1626

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host ip address dhcp


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ActiveEth24PortAM(1187560F1)

Command ID
142855

6TANV57CLI-35A

2-1627

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipdefaultgatewayA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip default-gateway 192.168.0.254

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
104999

2-1628

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Usage Examples
Thefollowingisanexampleofhowtousethesubtendedhostipfileserverdefaulthost
A.B.C.Dcommand.
(config-efm-group 1/18/1)#subtended-host ip file-server default host
192.168.0.1

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105003

6TANV57CLI-35A

2-1629

Total Access/NetVanta Carrier CLI Dictionary

subtended-host mode [disabled|listener|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

listener

Acceptssubtendedhostparametersfromconnecteddevice

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105017

2-1630

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105016

6TANV57CLI-35A

2-1631

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105014

2-1632

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105012

6TANV57CLI-35A

2-1633

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server ez-provisioning host A.B.C.D


traps version [1|2c]
Syntax Description
A.B.C.D

IPaddress

Version1

2c

Version2c

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138283

2-1634

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host snmp-server location WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138292

6TANV57CLI-35A

2-1635

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag [<1-4094>|inherit]


Syntax Description
<14094>

VIDoftheinbandmanagmentVlan

inherit

InheritVIDfromtheSystemManagementEVC

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
105004

2-1636

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
105008

6TANV57CLI-35A

2-1637

Total Access/NetVanta Carrier CLI Dictionary

thresholds broadcasts 15-minute <0-4294967295>


Usethethresholdsbroadcasts15minute<04294967295>commandtoconfigurethealarm
thresholdforbroadcastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds broadcasts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44831

2-1638

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds broadcasts 24-hour <0-4294967295>


Usethethresholdsbroadcasts24hour<04294967295>commandtoconfigurethealarm
thresholdforbroadcastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds broadcasts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44833

6TANV57CLI-35A

2-1639

Total Access/NetVanta Carrier CLI Dictionary

thresholds discards 15-minute <0-4294967295>


Usethethresholdsdiscards15minute<04294967295>commandtoconfigurethealarm
thresholdforframesdiscardedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds discards 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44811

2-1640

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds discards 24-hour <0-4294967295>


Usethethresholdsdiscards24hour<04294967295>commandtoconfigurethealarm
thresholdforframesdiscardedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds discards 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44813

6TANV57CLI-35A

2-1641

Total Access/NetVanta Carrier CLI Dictionary

thresholds errors 15-minute <0-4294967295>


Usethethresholdserrors15minute<04294967295>commandtoconfigurethealarm
thresholdforCRCerrorsthatoccurina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds errors 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44781

2-1642

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds errors 24-hour <0-4294967295>


Usethethresholdserrors24hour<04294967295>commandtoconfigurethealarmthreshold
forCRCerrorsthatoccurina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds errors 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44783

6TANV57CLI-35A

2-1643

Total Access/NetVanta Carrier CLI Dictionary

thresholds giants 15-minute <0-4294967295>


Usethethresholdsgiants15minute<04294967295>commandtoconfigurethealarm
thresholdforoversizeframesthatoccurina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds giants 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44801

2-1644

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds giants 24-hour <0-4294967295>


Usethethresholdsgiants24hour<04294967295>commandtoconfigurethealarmthreshold
foroversizeframesthatoccurina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds giants 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44803

6TANV57CLI-35A

2-1645

Total Access/NetVanta Carrier CLI Dictionary

thresholds invalid-vlan 15-minute <0-4294967295>


Usethethresholdsinvalidvlan15minute<04294967295>commandtoconfigurethealarm
thresholdforframeswithinvalidVLANreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds invalid-vlan 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82033

2-1646

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds invalid-vlan 24-hour <0-4294967295>


Usethethresholdsinvalidvlan24hour<04294967295>commandtoconfigurethealarm
thresholdforframeswithinvalidVLANreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds invalid-vlan 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82035

6TANV57CLI-35A

2-1647

Total Access/NetVanta Carrier CLI Dictionary

thresholds link-state-awareness bandwidth-minimum <02147483647>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142689

2-1648

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds link-state-awareness links-minimum <0-n>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142691

6TANV57CLI-35A

2-1649

Total Access/NetVanta Carrier CLI Dictionary

thresholds multicasts 15-minute <0-4294967295>


Usethethresholdsmulticasts15minute<04294967295>commandtoconfigurethealarm
thresholdformulticastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds multicasts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44821

2-1650

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds multicasts 24-hour <0-4294967295>


Usethethresholdsmulticasts24hour<04294967295>commandtoconfigurethealarm
thresholdformulticastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds multicasts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44823

6TANV57CLI-35A

2-1651

Total Access/NetVanta Carrier CLI Dictionary

thresholds peak-mac-entries 15-minute <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries15minute<0n>
command.
838_112(config-gig-eth 1/0/1)#thresholds peak-mac-entries 15-minute 40
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89706

2-1652

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds peak-mac-entries 24-hour <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries24hour<0n>
command.
838_112(config-gig-eth 1/0/1)#thresholds peak-mac-entries 24-hour 70
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89708

6TANV57CLI-35A

2-1653

Total Access/NetVanta Carrier CLI Dictionary

thresholds runts 15-minute <0-4294967295>


Usethethresholdsrunts15minute<04294967295>commandtoconfigurethealarm
thresholdforundersizedframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds runts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44791

2-1654

6TANV57CLI-35A

Section 2, Commands - Gigabit-Ethernet Interface Configuration Command Set

thresholds runts 24-hour <0-4294967295>


Usethethresholdsrunts24hour<04294967295>commandtoconfigurethealarmthreshold
forundersizedframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds runts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44793

6TANV57CLI-35A

2-1655

Total Access/NetVanta Carrier CLI Dictionary

Global Configuration Command Set


UsetheGlobalConfigurationCommandSettoconfiguretheglobalsystemparametersandto
enterintoanyoftheotherconfigurationmodes.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#

Functional Notes
Thiscommandsetisonlyaccessableviatheconfigureterminalorconfigurenetwork
commands.Thesecommandsarelimitedtotheenablerealm,andthusareonlyaccessibleby
writeprivledgedusers.Anythingthatisprovisionable,configurable,andlivesinnonvol
shouldhaveaplaceinthiscommandset.
ThefollowingisalistofcommandsavailableintheGlobalConfigurationCommandSet.
aaaaccountingcommands<1,15>defaultnone
aaaaccountingcommands<1,15>defaultstoponlygrouptacacs+
aaaaccountingexecdefaultnone
aaaaccountingexecdefaultstartstopgrouptacacs+
aaaaccountingexecdefaultstoponlygrouptacacs+
aaaaccountingupdatenewinfo
aaaaccountingupdateperiodic<11440>
aaaauthenticationeep
aaaauthenticationlogindefaultgroup[radius|tacacs+]
aaaauthenticationlogindefaultgroupradiuslocal
aaaauthenticationlogindefaultgrouptacacs+groupradius
aaaauthenticationlogindefaultgrouptacacs+groupradiuslocal
aaaauthenticationlogindefaultgrouptacacs+local
aaaauthenticationlogindefaultlocal
aaaauthorizationcommands<1,15>defaultgrouptacacs+
aaaauthorizationcommands<1,15>defaultnone
aaaauthorizationconfigcommand
aaaauthorizationexecdefaultgrouptacacs+
aaaauthorizationexecdefaultnone
arptimeout<shelf/slot>
arptimeout<shelf/slot><02147460>
autoprovisioning[controller|module]
autoupgrade
bannerlogin<character>
bootsystemflashWORD
bootsystemflashWORDWORD
clockdstautoadjust

2-1656

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

clockdstautoadjustpre2007
clockset<HH:MM:SS>
clockset<HH:MM:SS><131>MONTH<20002036>
clocktimezoneWORD<2323>
clocktimezoneWORD<2323><059>
counterprofile<shelf/slot/index>
dynamiccounter<shelf/slot/index>
end
ethernetcfm[defaultdomain|enable]
ethernetcfmdomaincharstringWORDlevel<07>
ethernetcfmdomaincharstringWORDlevel<07>index<1n>
ethernetcfmtraceroutecacheholdtime<165535>
ethernetcfmtraceroutecacheholdtime<165535>size<14095>
ethernetcfmtraceroutecachesize<14095>
ethernetdefaultinterfaceefmgroup[<shelf/slot/group>|WORD]
ethernetdefaultinterfaceerps<shelf/slot/ring>
ethernetdefaultinterfacegigabitethernet<shelf/slot/port>
ethernetdefaultinterfacelaggroup[<shelf/slot/group>|WORD]
ethernetdefaultinterfacerpr<shelf/slot/ring>
ethernetdefaultinterfacetengigabitethernet<shelf/slot/port>
ethernetinternalsystemstag<24094>
ethernetstagtpidHHHH
evcWORD
evcmapWORD
evcmapWORD<shelf/slot>
eventlogexport
exit
ezprovisioning
fan<shelf/slot>
fxsbatteryremove
fxsbatteryremove<shelf/slot>
interfaceadsl<shelf/slot/port>
interfaceatm[<shelf/slot/port>|<shelf/slot/port.sub>]
interfaceatmgroup<shelf/slot/group>legacyatm
interfacee1<shelf/slot/port>
interfaceefmgroup[<shelf/slot/group>|WORD]
interfaceefmlink[<shelf/slot/port>|<shelf/slot/port:chan>]
interfaceefmport<shelf/slot/port>
interfaceerps<shelf/slot/ring>

6TANV57CLI-35A

2-1657

Total Access/NetVanta Carrier CLI Dictionary

interfaceethernet<shelf/slot/port>
interfaceframerelay<shelf/slot/group>
interfaceframerelay<shelf/slot/group>dlci<16991>
interfacefxs[<shelf/slot/port>|<remoteindex>]
interfacegigabitethernet[<shelf/slot/port>|<remoteindex>]
interfacegpon<shelf/slot/port>
interfacehdsl2<shelf/slot/port>
interfacehdsl4<shelf/slot/port>
interfaceiphostWORD[<shelf/slot>|<remoteindex>]
interfacelaggroup[<shelf/slot/group>|WORD]
interfacemuxponderhighspeed<shelf/slot/interface>tengigabitethernet
interfacemuxpondermidspeed<shelf/slot/interface>gigabitethernet
interfacepackettiming<shelf/slot>
interfacepppgroup[<shelf/slot/group>|WORD]
interfacepseudowire[<shelf/slot/pwe>|<remoteindex>]cem
interfacerfvideo<remoteindex>
interfaceshdsl<shelf/slot/port>
interfacet1[<shelf/slot/port>|<shelf/slot/port:chan>]
interfacet3<shelf/slot/port>
interfacetengigabitethernet<shelf/slot/port>
interfacevdsl<shelf/slot/port>
ip[domainlookup|forwarding|syslog]
ipaccessliststandardWORD
ipdefaultgatewayA.B.C.D
ipdomainnamelistLINE
ipfileserverautoupgradefilenameWORD
ipfileserverautoupgradepathWORD
ipfileserverdefaultfilenameWORD
ipfileserverdefaulthostA.B.C.D
ipfileserverdefaultpathWORD
ipfileserverdefaultprotocol[filetransferovertl1|ftp|sftp|tftp]
ipfileserverdefaultusernameWORD
ipfileserverdefaultusernameWORDpassword
ipfileserverdownloadcacheexpire<601440>
ipfileservereventlogexporthostA.B.C.D
ipfileservereventlogexportpathWORD
ipfileservergeneralexporthostA.B.C.D
ipfileservergeneralexportpathWORD
ipfileservergeneralexportretries<02>

2-1658

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ipfileserverscafilenameWORD
ipfileserverscahostA.B.C.D
ipfileserversyslogexporthostA.B.C.D
ipigmpevcWORD<shelf/slot>mode[proxy|snooping|transparent]
ipigmpevcWORD<shelf/slot>proxyhostipaddressA.B.C.D
ipigmpevcWORD<shelf/slot>proxylastmemberquerycount<1255>
ipigmpevcWORD<shelf/slot>proxylastmemberqueryinterval<10065535>
ipnameserverprimaryA.B.C.D
ipnameserversecondaryA.B.C.D
ipntpserverA.B.C.Dprefer
ipntpserverA.B.C.Dpreferversion<34>
ipntpserverA.B.C.Dversion<34>
ipntpserverA.B.C.Dversion<34>prefer
ippowersheddingremoteserverA.B.C.D
iprawtl1[server|tcpdeadclient]
iprawtl1server<102465535>
iprawtl1server<102465535>ssh
iprouteA.B.C.DA.B.C.DA.B.C.D
iprtpudp<102660000>
ipsnmpagent
ipsntprefreshperiod<160>
ipsntpserverA.B.C.D
ipssh[server|tunnels]
ipsshkeysize<5122048>
ipsshserver<102465535>
ipsshtl1server
ipsshtl1server<102465535>
ipsshtl1secondaryserver
ipsshtl1secondaryserver<102465535>
iptelnet[deadclient|server]
iptelnetmode[cli|menus]
iptelnetserver<102465535>
iptelnetserver<102465535>ssh
iptelnetsecondarymode[cli|menus]
iptelnetsecondaryserver
iptelnetsecondaryserver<102465535>
iptelnetsecondaryserver<102465535>ssh
iptelnettl1server
iptelnettl1server<102465535>

6TANV57CLI-35A

2-1659

Total Access/NetVanta Carrier CLI Dictionary

iptelnettl1server<102465535>ssh
ipterminalservertelnetadmin[security|server]
ipterminalservertelnetadminserver<102465535>
ipterminalservertelnetadminserver<102465535>sshtunnel
ipterminalservertelnetnetwork[security|server]
ipterminalservertelnetnetworkserver<102465535>
ipterminalservertelnetnetworkserver<102465535>sshtunnel
lineadmin<0>
lineconsole<0>
linenetwork<0>
linetimeout<0n>
mevcWORD<shelf/slot>
mode[<shelf/slot>|<remoteindex>]voicefxssignaling
mode[<shelf/slot>|<remoteindex>]voicemgcp
mode[<shelf/slot>|<remoteindex>]voicesip
muxponderethernet<shelf/slot>qoscosmap<0n><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07><07><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07><07><07><07>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07><07><07><07><0
7>
muxponderethernet<shelf/slot>qoscosmap<0n><07><07><07><07><07><07><0
7><07>
muxponderethernet<shelf/slot>qosuntagged<07>
muxponderethernet<shelf/slot>queuetimeconstantwred
[125|16|2|250|32|4|500|62|8]
networknameWORD
nodenumber<1n>
policerWORD
policerWORD<shelf/slot>
powershedding
proberespondertwamp
protectiongroup[<shelf/group>|WORD]
qoscosmap<0n><07>
qoscosmap<0n><07><07>
qoscosmap<0n><07><07><07>
qoscosmap<0n><07><07><07><07>

2-1660

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qoscosmap<0n><07><07><07><07><07>
qoscosmap<0n><07><07><07><07><07><07>
qoscosmap<0n><07><07><07><07><07><07><07>
qoscosmap<0n><07><07><07><07><07><07><07><07>
qosuntagged<07>
queueinterfaceefmgroup[<shelf/slot/group>|WORD]<0n>
queueinterfaceethernet<shelf/slot/port><0n>
queueinterfacegigabitethernet<shelf/slot/port><0n>
queueinterfacemuxponderhighspeed<shelf/slot/port><0n>
queueinterfacemuxpondermidspeed<shelf/slot/port><0n>
queueinterfacetengigabitethernet<shelf/slot/port><0n>
queuetimeconstantwred[125|16|2|250|32|4|500|62|8]
radiusserverauthport<102465535>
radiusserverdefaultprivilege[admin|config|readonly|readwrite|test]
radiusserverhostA.B.C.Dauthport<102465535>keyWORD
radiusserverhostA.B.C.Dauthport<102465535>keyWORDtimeout<130>
radiusserverhostA.B.C.Dauthport<102465535>timeout<130>
radiusserverhostA.B.C.Dauthport<102465535>timeout<130>keyWORD
radiusserverhostA.B.C.DkeyWORDauthport<102465535>
radiusserverhostA.B.C.DkeyWORDauthport<102465535>timeout<130>
radiusserverhostA.B.C.DkeyWORDtimeout<130>
radiusserverhostA.B.C.DkeyWORDtimeout<130>authport<102465535>
radiusserverhostA.B.C.DnameWORD
radiusserverhostA.B.C.Dretransmit<1255>
radiusserverhostA.B.C.Dsequencenumber<04>
radiusserverhostA.B.C.Dtimeout<130>authport<102465535>
radiusserverhostA.B.C.Dtimeout<130>authport<102465535>keyWORD
radiusserverhostA.B.C.Dtimeout<130>keyWORD
radiusserverhostA.B.C.Dtimeout<130>keyWORDauthport<102465535>
radiusserverkeyWORD
radiusserverretransmit<1255>
radiusservertimeout<130>
radiusservertl1login
redundancy<shelf/slot>
remotedeviceont<remoteindex>
sca
scrmode[auto|manual|scheduled]
scrschedule<HH:MM><131>MONTH<20002099>
security

6TANV57CLI-35A

2-1661

Total Access/NetVanta Carrier CLI Dictionary

shaperWORD[<shelf/slot>|<remoteindex>]
shdslmode[ltu|ntu]
shdsltimeouttraining<60240>
slotalarmenableshutdownmaintenance<shelf/slot>
slotshutdown<shelf/slot>
slotshutdownmaintenance<shelf/slot>
slotshutdownunassigned<shelf/slot>
slotalarm<shelf/slot>
snmpserver[chassisidtidsync|configchange|nonvolcardstatus]
snmpserveralarmenableauthenticatefailure
snmpserverchassisidWORD
snmpservercommunityreadonlyWORD
snmpservercommunityreadwriteWORD
snmpserverconfigchangeignoresourceA.B.C.D
snmpserverconfigchangeignoretypecontroller
snmpservercontactWORD
snmpserverenabletraps
snmpserverezprovisioninghostA.B.C.Dtrapsversion[1|2c]
snmpserverhostA.B.C.D
snmpserverhostA.B.C.Dtraps[configchange|confirmation]
snmpserverhostA.B.C.Dtrapsconfigchangeenable
snmpserverhostA.B.C.Dtrapsmode[invalid|undercreation|valid]
snmpserverhostA.B.C.Dtrapsretrylimit<010>
snmpserverhostA.B.C.Dtrapstimeout<110>
snmpserverhostA.B.C.Dtrapsversion[1|2c]
snmpserverifindexmode[fixed|sequential]
snmpserverlocationWORD
srm
systemalarm
systemalarm<shelf>
systemmanagementevc
systemtiming<shelf>
t1e1mode[e1|t1]
tacacsserverhostA.B.C.DkeyWORDport<165535>
tacacsserverhostA.B.C.DkeyWORDport<165535>timeout<130>
tacacsserverhostA.B.C.DkeyWORDtimeout<130>
tacacsserverhostA.B.C.DkeyWORDtimeout<130>port<165535>
tacacsserverhostA.B.C.DnameWORD
tacacsserverhostA.B.C.Dport<165535>keyWORD

2-1662

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacsserverhostA.B.C.Dport<165535>keyWORDtimeout<130>
tacacsserverhostA.B.C.Dport<165535>timeout<130>
tacacsserverhostA.B.C.Dport<165535>timeout<130>keyWORD
tacacsserverhostA.B.C.Dsequencenumber<04>
tacacsserverhostA.B.C.Dtimeout<130>keyWORD
tacacsserverhostA.B.C.Dtimeout<130>keyWORDport<165535>
tacacsserverhostA.B.C.Dtimeout<130>port<165535>
tacacsserverhostA.B.C.Dtimeout<130>port<165535>keyWORD
tacacsserverkeyWORD
tacacsserverport<165535>
tacacsservertimeout<130>
temperaturesensor<shelf/slot/sensor>
tl1
voiceclassofserviceWORD
voiceconferencelocaloriginatorflashhook[drop|ignore|split]
voiceconferencemode[local|network]
voicedialplan900number<PATTERN>
voicedialplanalwayspermitted<PATTERN>
voicedialplaninternal<PATTERN>
voicedialplaninternational<PATTERN>
voicedialplanlocal<PATTERN>
voicedialplannational<PATTERN>
voicedialplanoperatorassisted<PATTERN>
voicedialplanspecifycarrier<PATTERN>
voicedialplantollfree<PATTERN>
voicedialplanuser1<PATTERN>
voicedialplanuser2<PATTERN>
voicedialplanuser3<PATTERN>
voiceflashhookmode[interpreted|transparent]
voicesiptrunk<Txx>
voicespre<PATTERN>
voiceuserNUMBER:20

6TANV57CLI-35A

2-1663

Total Access/NetVanta Carrier CLI Dictionary

aaa accounting commands <1,15> default none


Usetheaaaaccountingcommands<1,15>defaultnonecommandtodisableremotecommand
accountingforthespecifiedlevel.

Syntax Description
<1,15>

Unprivileged,privilegedcommands

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingcommands<1,15>defaultnone
command.
(config)#aaa accounting commands 1 default none
(config)#

Functional Notes
CommandaccountingistheprocessofnotifyingaTACACS+serverwhenaCLIcommandis
executed.ThisallowsaTACACS+servertomaintainlogsofCLIcommandactivityforeach
user.
Commandaccountingisenabledbasedonacommandslevel(1,15).Onapercommand
basis,thenetworkelementwilltransmitacommandaccountingrequesttotheremoteserver,
effectivelynotifyingtheserverthatthegivenuserhasexecutedthecommand.Theresponse
fromtheserverdoesnothaveanyconsequenceotherthantheupdateofaccountingstatistics.
CommandshavingTACACS+level0arenotsubjecttoremotecommandaccounting.
CommandaccountingissupportedviaTACACS+only,andonlyifTACACS+isamongthe
methodsintheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1664

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Command ID
44056

6TANV57CLI-35A

2-1665

Total Access/NetVanta Carrier CLI Dictionary

aaa accounting commands <1,15> default stop-only group


tacacs+
Usetheaaaaccountingcommands<1,15>defaultstoponlygrouptacacs+commandtoenable
remotecommandaccountingbasedonthecommandsprivilegelevel.Usethenoformofthis
commandtodisableremotecommandaccountingforthespecifiedlevel.

Syntax Description
<1,15>

Unprivileged,privilegedcommands

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingcommands<1,15>defaultstop
onlygrouptacacs+command.
(config)#aaa accounting commands 1 default stop-only group tacacs+
(config)#

Functional Notes
CommandaccountingistheprocessofnotifyingaTACACS+serverwhenaCLIcommandis
executed.ThisallowsaTACACS+servertomaintainlogsofCLIcommandactivityforeach
user.
Commandaccountingisenabledbasedonacommandslevel(1,15).Onapercommand
basis,thenetworkelementwilltransmitacommandaccountingrequesttotheremoteserver,
effectivelynotifyingtheserverthatthegivenuserhasexecutedthecommand.Theresponse
fromtheserverdoesnothaveanyconsequenceotherthantheupdateofaccountingstatistics.
CommandshavingTACACS+level0arenotsubjecttoremotecommandaccounting.
CommandaccountingissupportedviaTACACS+only,andonlyifTACACS+isamongthe
methodsintheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1666

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Command ID
44062

6TANV57CLI-35A

2-1667

Total Access/NetVanta Carrier CLI Dictionary

aaa accounting exec default none


Usetheaaaaccountingexecdefaultnonecommandtodisableexecaccounting.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingexecdefaultnonecommand.
(config)#aaa accounting exec default none
(config)#

Functional Notes
Whereascommandaccountingisusedtologexecutedcommands,execaccountinglogsthe
openingand/orclosingofCLIsessionsandfailedauthenticationattempts.
WhenexecaccountingisenabledandauserauthenticatessuccessfullyatloginorclosesaCLI
session,thenanaccountingrecordisthentransmittedtotheservertoindicatetheuserhas
openedorclosedtheCLIsession.
ExecaccountingissupportedviaTACACS+only,andonlyifTACACS+isamongthemethods
intheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44068

2-1668

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa accounting exec default start-stop group tacacs+


Usetheaaaaccountingexecdefaultstartstopgrouptacacs+commandtoenableTACACS+
execaccountingforboththeopeningandclosingofCLIsessions.Usethenoformofthis
commandtodisableexecaccounting.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingexecdefaultstartstopgroup
tacacs+command.
(config)#aaa accounting exec default start-stop group tacacs+
(config)#

Functional Notes
Whereascommandaccountingisusedtologexecutedcommands,execaccountinglogsthe
openingand/orclosingofCLIsessionsandfailedauthenticationattempts.
WhenexecaccountingisenabledandauserauthenticatessuccessfullyatloginorclosesaCLI
session,thenanaccountingrecordisthentransmittedtotheservertoindicatetheuserhas
openedorclosedtheCLIsession.
ExecaccountingissupportedviaTACACS+only,andonlyifTACACS+isamongthemethods
intheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44074

6TANV57CLI-35A

2-1669

Total Access/NetVanta Carrier CLI Dictionary

aaa accounting exec default stop-only group tacacs+


Usetheaaaaccountingexecdefaultstoponlygrouptacacs+commandtoenableTACACS+
execaccountingfortheclosingofCLIsessionsonly.Usethenoformofthiscommandto
disableexecaccounting.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingexecdefaultstoponlygroup
tacacs+command.
(config)#aaa accounting exec default stop-only group tacacs+
(config)#

Functional Notes
Whereascommandaccountingisusedtologexecutedcommands,execaccountinglogsthe
openingand/orclosingofCLIsessionsandfailedauthenticationattempts.
WhenexecaccountingisenabledandauserauthenticatessuccessfullyatloginorclosesaCLI
session,thenanaccountingrecordisthentransmittedtotheservertoindicatetheuserhas
openedorclosedtheCLIsession.
ExecaccountingissupportedviaTACACS+only,andonlyifTACACS+isamongthemethods
intheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44080

2-1670

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa accounting update newinfo


Usetheaaaaccountingupdatenewinfocommandtosendeachaccountingrecordtothe
serverimmediatelyaftertheCLIcommandisexecuted.Usethenoformofthiscommandto
setthetimeintervaltothedefaultperiodicinterval(fiveminutes).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingupdatenewinfocommand.
(config)#aaa accounting update newinfo
(config)#

Functional Notes
Commandandexecaccountingrecordscanbeconfiguredtobetransmittedalmostimmedi
atelyafterthetheyarecreated,oraccumulatedandtransmittedoveraperiodicintervalof
time.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44040

6TANV57CLI-35A

2-1671

Total Access/NetVanta Carrier CLI Dictionary

aaa accounting update periodic <1-1440>


Usetheaaaaccountingupdateperiodic<11440>commandtospecifythetimeinterval(in
minutes)betweenaccountingrecordssenttotheserver.Usethenoformofthiscommandto
setthetimeintervaltothedefaultinterval(fiveminutes).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaaccountingupdateperiodic<11440>
command.
(config)#aaa accounting update periodic 600
(config)#

Functional Notes
Commandandexecaccountingrecordscanbeconfiguredtobetransmittedalmostimmedi
atelyafterthetheyarecreated,oraccumulatedandtransmittedoveraperiodicintervalof
time.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44044

2-1672

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authentication eep


UsetheaaaauthenticationeepcommandtoenableEmergencyEntryPort(EEP)authenti
cation.EEPisabackdoorlocalauthenticationmethodtobeusedifallotherauthentication
methodsarenotsuccessful.WhenEEPisenabled,enterapredeterminedusername
(CHALLENGE)attheloginprompttogainaccesstothesystem.Thenetworkelement
presentsachallengekeyimmediatelyaftergainingaccessanddoesnotrequestapassword.
UsethenoformofthiscommandtodisableEEPauthentication.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationeepcommand.
(config)#aaa authentication eep
(config)#

Functional Notes
UsecautionwhendisablingEEP.IfEEPisdisabled,theabilitytoauthenticateatloginviathe
TechSupportChallengeKeyisnotavailable,andtotaluserlockoutwilloccurifotherauthen
ticationmethodsdonotgrantaccess.
EEPwithcommandauthorization:
Undertypicalconditions,aTACACS+servergrouptimeoutonacommandauthorization
requestwillresultinadenialofthecommand.Thiscanresultinalockoutscenarioifthe
networkelementisconfiguredforremotecommandauthorizationwhileothercriticalaspects
ofthenetworkelementprovisioningarenotcorrect(suchasiftheTACACS+serverIPaddress
orkeyismisconfigured).Toovercomesuchalockoutscenario,ifEEPisenabled,theuser
mayloginviaEEPchallenge.ForaCLIsessionthatissuccessfullyauthenticatedatloginvia
EEP,thenetworkelementwillcontinuetosendcommandauthorizationrequeststotheserver.
Buttheuserwillbepermittedtoexecuteacommandintheeventthatacommandauthori
zationresponseisnotsuccessfullyreceivedanddecoded.Commandauthorizationresponses
thataresuccessfullyreceivedanddecodedwillbeprocessednormally,thuspermittingor
denyingcommands.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1673

Total Access/NetVanta Carrier CLI Dictionary

Command ID
61454

2-1674

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authentication login default group [radius|tacacs+]


Usetheaaaauthenticationlogindefaultgroup[radius|tacacs+]commandtospecifywhich
groupofremoteservers(RADIUSorTACACS+)touseforauthentication.Usethenoformof
thiscommandtorestoretheauthenticationloginmethodlisttoitsdefaultmethods(local
databaseonly).

Syntax Description
radius

UseallRADIUSservers

tacacs+

UseallTACACS+servers

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultgroup
[radius|tacacs+]command.
(config)#aaa authentication login default group tacacs+
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1675

Total Access/NetVanta Carrier CLI Dictionary

Command ID
43988

2-1676

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authentication login default group radius local


Usetheaaaauthenticationlogindefaultgroupradiuslocalcommandtodesignatetheuseof
thefollowingmethods(inorder)duringauthenticationatlogin:RADIUSservers,local
database.Usethenoformofthiscommandtorestoretheauthenticationloginmethodlistto
itsdefaultmethods(localdatabaseonly).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultgroupradius
localcommand.
(config)#aaa authentication login default group radius local
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44002

6TANV57CLI-35A

2-1677

Total Access/NetVanta Carrier CLI Dictionary

aaa authentication login default group tacacs+ group radius


Usetheaaaauthenticationlogindefaultgrouptacacs+groupradiuscommandtodesignate
theuseofthefollowingmethods(inorder)duringauthenticationatlogin:TACACS+servers,
RADIUSservers.Usethenoformofthiscommandtorestoretheauthenticationloginmethod
listtoitsdefaultmethods(localdatabaseonly).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultgrouptacacs+
groupradiuscommand.
(config)#aaa authentication login default group tacacs+ group radius
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43994

2-1678

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authentication login default group tacacs+ group radius


local
Usetheaaaauthenticationlogindefaultgrouptacacs+groupradiuslocalcommandto
designatetheuseofthefollowingmethods(inorder)duringauthenticationatlogin:
TACACS+servers,RADIUSservers,localdatabase.Usethenoformofthiscommandto
restoretheauthenticationloginmethodlisttoitsdefaultmethods(localdatabaseonly).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultgrouptacacs+
groupradiuslocalcommand.
(config)#aaa authentication login default group tacacs+ group radius
local
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43996

6TANV57CLI-35A

2-1679

Total Access/NetVanta Carrier CLI Dictionary

aaa authentication login default group tacacs+ local


Usetheaaaauthenticationlogindefaultgrouptacacs+localcommandtodesignatetheuseof
thefollowingmethods(inorder)duringauthenticationatlogin:TACACS+servers,local
database.Usethenoformofthiscommandtorestoretheauthenticationloginmethodlistto
itsdefaultmethods(localdatabaseonly).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultgrouptacacs+
localcommand.
(config)#aaa authentication login default group tacacs+ local
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44004

2-1680

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authentication login default local


Usetheaaaauthenticationlogindefaultlocalcommandtodesignatetheuseofthefollowing
methods(inorder)duringauthenticationatlogin:localdatabase.Usethenoformofthis
commandtorestoretheauthenticationloginmethodlisttoitsdefaultmethods(localdatabase
only).

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthenticationlogindefaultlocal
command.
(config)#aaa authentication login default local
(config)#

Functional Notes
Theauthenticationloginmethodlistdefinesthemethodsandprotocolsusedforauthenti
cationatlogin.Italsodefinestheorderinwhichtheprotocolsareused.
Duringauthenticationatlogin,thenetworkelementwillquerytheprotocol(s)intheorderin
whichtheyappearintheauthenticationloginmethodlist.Ifatimeoutoccursonaprotocol,
thenafallbackwilloccurtothenextmethodintheauthenticationloginmethodlist.Ifa
remoteserveristobequeried,theneachenabledserverofthatrespectiveprotocol(TACACS+
orRADIUS)willbequeriedsequentiallybeforeafallbackoccurstothenextmethod.A
timeoutonamethodwillresultinafallbacktothenextmethod.Theauthenticationprocess
stopswiththefirstmethodthatproducesaresult(pass,fail,challenge).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44000

6TANV57CLI-35A

2-1681

Total Access/NetVanta Carrier CLI Dictionary

aaa authorization commands <1,15> default group tacacs+


Usetheaaaauthorizationcommands<1,15>defaultgrouptacacs+commandtoenable
commandauthorizationforallcommandsofthegivenlevel(1or15).Usethenoformofthis
commandtodisablecommandauthorizationforallcommandsofthatlevel.

Syntax Description
<1,15>

Unprivileged,privilegedcommands

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthorizationcommands<1,15>default
grouptacacs+command.
(config)#aaa authorization commands 1 default group tacacs+
(config)#

Functional Notes
Commandauthorizationcontrolswhetheranauthenticateduserisallowedtoexecute
individualcommands.Onapercommandbasis,thenetworkelementwilltransmita
commandauthorizationrequesttotheremoteserver,effectivelyaskingtheserverwhetherthe
givenusermayexecutethecommand.Iftheserverrespondspositively,thenthecommand
willbeexecuted.Iftheserverresponseisnegative,anAccessDeniedmessagewillbe
displayedtotheCLIsession,andthecommandwillnotbeexecuted.
Commandauthorizationisgenerallyenabledbasedonacommandslevel(1,15).Inaddition,
commandauthorizationcanbeseparatelyenabledordisabledforthelevel15commandsat
andbeyondtheconfigprompt(aaaauthorizationconfigcommand).Commandshaving
TACACS+level0arenotsubjecttoremotecommandauthorization.
CommandauthorizationissupportedviaTACACS+only,andonlyifTACACS+isamongthe
methodsintheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1682

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Command ID
44022

6TANV57CLI-35A

2-1683

Total Access/NetVanta Carrier CLI Dictionary

aaa authorization commands <1,15> default none


Usetheaaaauthorizationcommands<1,15>defaultnonecommandtodisablecommand
authorizationforallcommandsofthegivenlevel(1or15).

Syntax Description
<1,15>

Unprivileged,privilegedcommands

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthorizationcommands<1,15>default
nonecommand.
(config)#aaa authorization commands 15 default none
(config)#

Functional Notes
Commandauthorizationcontrolswhetheranauthenticateduserisallowedtoexecute
individualcommands.Onapercommandbasis,thenetworkelementwilltransmita
commandauthorizationrequesttotheremoteserver,effectivelyaskingtheserverwhetherthe
givenusermayexecutethecommand.Iftheserverrespondspositively,thenthecommand
willbeexecuted.Iftheserverresponseisnegative,anAccessDeniedmessagewillbe
displayedtotheCLIsession,andthecommandwillnotbeexecuted.
Commandauthorizationisgenerallyenabledbasedonacommandslevel(1,15).Inaddition,
commandauthorizationcanbeseparatelyenabledordisabledforthelevel15commandsat
andbeyondtheconfigprompt(aaaauthorizationconfigcommand).Commandshaving
TACACS+level0arenotsubjecttoremotecommandauthorization.
CommandauthorizationissupportedviaTACACS+only,andonlyifTACACS+isamongthe
methodsintheauthenticationloginmethodlist.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1684

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Command ID
44018

6TANV57CLI-35A

2-1685

Total Access/NetVanta Carrier CLI Dictionary

aaa authorization config-command


Usetheaaaauthorizationconfigcommandcommandtoenablecommandauthorizationfor
commandsatandbeyondtheconfigprompt.Usethenoformofthiscommandtodisable
commandauthorizationforthesecommands.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthorizationconfigcommandcommand.
(config)#aaa authorization config-command
(config)#

Functional Notes
Commandauthorizationcontrolswhetheranauthenticateduserisallowedtoexecute
individualcommands.Onapercommandbasis,thenetworkelementwilltransmita
commandauthorizationrequesttotheremoteserver,effectivelyaskingtheserverwhetherthe
givenusermayexecutethecommand.Iftheserverrespondspositively,thenthecommand
willbeexecuted.Iftheserverresponseisnegative,anAccessDeniedmessagewillbe
displayedtotheCLIsession,andthecommandwillnotbeexecuted.
CommandauthorizationissupportedviaTACACS+only,andonlyifTACACS+isamongthe
methodsintheauthenticationloginmethodlist.
Commandauthorizationisgenerallyenabledbasedonacommandslevel(1,15).Inaddition,
commandauthorizationcanbeseparatelyenabledordisabledforthelevel15commandsat
andbeyondtheconfigprompt(aaaauthorizationconfigcommand).Commandshaving
TACACS+level0arenotsubjecttoremotecommandauthorization.
Afteracommandisissuedtoenableordisablecommandauthorizationofalllevel15
commands,commandauthorizationforcommandsatandbeyondtheconfigterminalprompt
canbeseparatelyenabledordisabled.
Thefollowingcommandsequenceenablescommandauthorizationforalllevel15commands
exceptforthoseatorbeyondtheconfigterminalprompt:
aaaauthorizationcommand15defaultgrouptacacs+
noaaaauthorizationconfigcommand
Thefollowingcommandsequenceenablescommandauthorizationforalllevel15commands
exceptforthosepriortotheconfigterminalprompt:
aaaauthorizationcommand15defaultnone
aaaauthorizationconfigcommand

2-1686

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44008

6TANV57CLI-35A

2-1687

Total Access/NetVanta Carrier CLI Dictionary

aaa authorization exec default group tacacs+


Usetheaaaauthorizationexecdefaultgrouptacacs+commandtoenableexecauthorization
viaTACACS+.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthorizationexecdefaultgrouptacacs+
command.
(config)#aaa authorization exec default group tacacs+
(config)#

Functional Notes
Whereascommandauthorizationisperformedonapercommandbasis,execauthorizationis
performedonlyaftersuccessfulTACACS+authenticationatlogin.Whenexecauthorization
isenabledandauserauthenticatessuccessfullyatloginviaTACACS+,anexecauthorization
requestisthentransmittedtotheservertoeffectivelydeterminewhethertheuserhasshell
access.
Iftheserverreturnsaresponsewithapassingresult,thentheCLIsessionproceedsdirectlyto
theEnableprompt.
Iftheserverreturnsaresponsewithanegativeresult(orifnoresponseisreceived),thenthe
CLIsessionproceedstotheRootprompt,andtheuserissubjecttoTACACSreauthentication
priortoenteringtheEnableprompt.
ExecauthorizationissupportedviaTACACS+only,andonlyforCLIsessionswhere
TACACS+isthefinalauthenticationmethodatlogin.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44030

2-1688

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

aaa authorization exec default none


Usetheaaaauthorizationexecdefaultnonecommandtodisableexecauthorization.

Usage Examples
Thefollowingisanexampleofhowtousetheaaaauthorizationexecdefaultnonecommand.
(config)#aaa authorization exec default none
(config)#

Functional Notes
Whereascommandauthorizationisperformedonapercommandbasis,execauthorizationis
performedonlyaftersuccessfulTACACS+authenticationatlogin.Whenexecauthorization
isenabledandauserauthenticatessuccessfullyatloginviaTACACS+,anexecauthorization
requestisthentransmittedtotheservertoeffectivelydeterminewhethertheuserhasshell
access.
Iftheserverreturnsaresponsewithapassingresult,thentheCLIsessionproceedsdirectlyto
theEnableprompt.
Iftheserverreturnsaresponsewithanegativeresult(orifnoresponseisreceived),thenthe
CLIsessionproceedstotheRootprompt,andtheuserissubjecttoTACACSreauthentication
priortoenteringtheEnableprompt.
ExecauthorizationissupportedviaTACACS+only,andonlyforCLIsessionswhere
TACACS+isthefinalauthenticationmethodatlogin.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44034

6TANV57CLI-35A

2-1689

Total Access/NetVanta Carrier CLI Dictionary

arp timeout <shelf/slot>


Usethearptimeout<shelf/slot>commandtosetthearptimeoutforthespecifiedslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
89373

2-1690

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

arp timeout <shelf/slot> <0-2147460>


Usethearptimeout<shelf/slot><042147460>commandtosetthearptimeoutforthe
specifiedslot.

Syntax Description
<shelf/slot>

Specifiedshelf/slot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
89538

6TANV57CLI-35A

2-1691

Total Access/NetVanta Carrier CLI Dictionary

auto-provisioning [controller|module]
Useautoprovisioning[controller|module]commandtoenableautoprovisioningonthe
moduleortoenableMNPSonthecontroller.Usethenoformofthiscommandtodisable
autoprovisioningorMNPS.

Syntax Description
controller

Automaticprovisioningofthecontroller

module

Automaticprovisioningofthemodules

Usage Examples
Thefollowingisanexampleofhowtousetheautoprovisioning[controller|module]
command.
(config)#auto-provisioning module
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
79435

2-1692

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

auto-upgrade
UsetheautoupgradecommandtoactivatetheAutoUpgradeConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousetheautoupgradecommand.
(config)#auto-upgrade
(config-auto-upgrade)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77124

6TANV57CLI-35A

2-1693

Total Access/NetVanta Carrier CLI Dictionary

banner login <character>


Usethebannerlogin<character>commandtosetthesecurityadvisorywarningmessagethat
isdisplayedatlogin.Usethenoformofthiscommandtosetthesecurityadvisorywarning
messagetothedefault.

Usage Examples
Thefollowingisanexampleofhowtousethebannerlogin<character>command.
(config)#banner login @
Enter TEXT message.
Notice:

End with the character '@'

This is a private network.

Unauthorized access or use may lead to prosecution.@


(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
89410

2-1694

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

boot system flash WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV8044(1172804G1)

Command ID
100125

6TANV57CLI-35A

2-1695

Total Access/NetVanta Carrier CLI Dictionary

boot system flash WORD WORD


Syntax Description
WORD

Primaryimagefilename

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV8044(1172804G1)

Command ID
100127

2-1696

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

clock dst-auto-adjust
UsetheclockdstautoadjustcommandtoenableDaylightSavingsTimeadjustmentstothe
clock.UsethenoformofthiscommandtodisableDaylightSavingsTimeadjustments.

Usage Examples
Thefollowingisanexampleofhowtousetheclockdstautoadjustcommand.
(config)#clock dst-auto-adjust
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87124

6TANV57CLI-35A

2-1697

Total Access/NetVanta Carrier CLI Dictionary

clock dst-auto-adjust pre-2007


Usetheclockdstautoadjustpre2007commandtoenablepre2007DaylightSavingsTime
adjustmentstotheclock.UsethenoformofthiscommandtodisableDaylightSavingsTime
adjustments.

Usage Examples
Thefollowingisanexampleofhowtousetheclockdstautoadjustpre2007command.
(config)#clock dst-auto-adjust pre-2007
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87129

2-1698

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

clock set <HH:MM:SS>


Usetheclockset<HH:MM:SS>commandtosetthecurrenttimein24hourformat.

Usage Examples
Thefollowingisanexampleofhowtousetheclockset<HH:MM:SS>command.
(config)#clock set 10:30:05
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43736

6TANV57CLI-35A

2-1699

Total Access/NetVanta Carrier CLI Dictionary

clock set <HH:MM:SS> <1-31> MONTH <2000-2036>


Usetheclockset<HH:MM:SS><131>WORD<20002036>commandtosetthecurrenttimein
24hourformatanddate.

Syntax Description
<HH:MM:SS>

Currenttimein24hourformat

<131>

Thedayofthemonth

MONTH

Monthoftheyear

Usage Examples
Thefollowingisanexampleofhowtousetheclockset<HH:MM:SS><131>MONTH<2000
2036>command.
(config)#clock set 11:30:00 8 November 2008
(config)#

Functional Notes
Usethe<HH:MM:SS>inputthesetthecurrenttimein24hourformat.
Usethe<131>inputtosetthecurrentdate(validrange:1to31).
UsetheWORDinputtosetthecurrentmonth.
Thevalidrangefortheyearis2000to2036.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64890

2-1700

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

clock timezone WORD <-23-23>


UsetheclocktimezoneWORD<2323>commandtosetthenameofthetimezoneandthe
hoursoffsetfromUTC.

Syntax Description
WORD

Nameoftimezone

Usage Examples
ThefollowingisanexampleofhowtousetheclocktimezoneWORD<2323>command.
(config)#clock timezone CST -6
(config)#

Functional Notes
UsetheWORDinputtodesignatethetimezone.
Thevalidrangeforthehoursoffsetis23to23.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64900

6TANV57CLI-35A

2-1701

Total Access/NetVanta Carrier CLI Dictionary

clock timezone WORD <-23-23> <0-59>


UsetheclocktimezoneWORD<2323><059>commandtosetthenameofthetimezone,the
hoursoffset,andtheminutesoffsetfromUTC.

Syntax Description
WORD

Nameoftimezone

<2323>

HoursoffsetfromUTC

Usage Examples
ThefollowingisanexampleofhowtousetheclocktimezoneWORD<2323><059>
command.
(config)#clock timezone CST -6 0
(config)#

Functional Notes
UsetheWORDinputtodesignatethetimezone.
Usethe<2323>inputtosetthehoursoffsetfromUTC(validrange:23to23).
Thevalidrangefortheminutesoffsetis0to59.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64901

2-1702

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

counter-profile <shelf/slot/index>
Usethecounterprofile<shelf/slot/index>commandtoactivatetheCounterProfileConfigu
rationCommandSetforthespecifiedprofile.

Usage Examples
Thefollowingisanexampleofhowtousethecounterprofile<shelf/slot/index>command.
(config)#counter profile 1/0/2
(config-count-prof 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46051

6TANV57CLI-35A

2-1703

Total Access/NetVanta Carrier CLI Dictionary

dynamic-counter <shelf/slot/index>
Usethedynamiccounter<shelf/slot/index>commandtoactivatetheDynamicCounter
ConfigurationCommandSetforthespecifiedcounter.

Usage Examples
Thefollowingisanexampleofhowtousethedynamiccounter<shelf/slot/index>command.
(config)#dynamic-counter 1/0/3
(config-dyn-count 1/0/3)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),QuadGigELM
(1187550G2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),10GEthernet
Muxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),
SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46049

2-1704

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

end
Usetheendcommandtoexitthecurrentconfigurationmodeandentertheenablesecurity
mode.

Usage Examples
Thefollowingisanexampleofhowtousetheendcommand.
(config)#end
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),SM
10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwith
Bridging(1187011G1),TA3002POTS2GE(1187602G2),TA3242POTS4GE
(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1705

Total Access/NetVanta Carrier CLI Dictionary

Command ID
65655

2-1706

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet cfm [default-domain|enable]


Syntax Description
cfm

EnableConnectivityFaultManagement(CFM)subsystem

defaultdomain

Modifythedefaultmaintenancedomainsettings

enable

EnableConnectivityFaultManagement(CFM)subsystem

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45166

6TANV57CLI-35A

2-1707

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm domain char-string WORD level <0-7>


UsetheethernetcfmdomaincharstringWORDlevel<07>commandtocreateaCFM
maintenancedomainandactivatetheMaintenanceDomainConfigurationCommandSet.Use
thenoformofthiscommandtodeletethespecifiedmaintenancedomainandremoveany
maintenanceassociationsandMEPsdefinedwithinthedomain.

Syntax Description
WORD

Entername

Usage Examples
ThefollowingisanexampleofhowtousetheethernetcfmdomaincharstringWORDlevel
<07>command.
(config)#ethernet cfm domain char-string ecfm level 1
(config-ecfm-domain ecfm)#

Functional Notes
ThepromptchangesasverificationthattheMaintenanceDomainConfigurationcommands
areavailable.
UsetheWORDinputtonamethenewCFMmaintenancedomain.
Thevalidrangeforthelevelis0to7.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45189

2-1708

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet cfm domain char-string WORD level <0-7> index <1n>


UsetheethernetcfmdomaincharstringWORDlevel<07>index<1n>commandtocreate/
accessaCFMmaintenancedomaininaspecificMIBindexandactivatetheMaintenance
DomainConfigurationCommandSet.Usethenoformofthiscommandtodeletethe
specifiedmaintenancedomainandremoveanymaintenanceassociationsandMEPsdefined
withinthedomain.

Syntax Description
WORD

Entername

<07>

Enterlevel

Usage Examples
ThefollowingisanexampleofhowtousetheethernetcfmdomaincharstringWORDlevel
<07>index<1n>command.
(config)#ethernet cfm domain char-string MD_1 level 1 index 1
(config-ecfm-domain ecfm)#

Functional Notes
ThepromptchangesasverificationthattheMaintenanceDomainConfigurationcommands
areavailable.
UsetheWORDinputtonamethenewCFMmaintenancedomain.
Thevalidrangeforthelevelis0to7.
ThevalidrangefortheMIBindexis1to65536.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1709

Total Access/NetVanta Carrier CLI Dictionary

Command ID
45191

2-1710

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet cfm traceroute cache hold-time <1-65535>


Usetheethernetcfmtraceroutecacheholdtime<165535>commandtoadjustthetraceroute
cachetimeout.WhenanMEPperformsatraceroute,theresultsareaddedtothetraceroute
cachewheretheresultsarestoreduntiltimedout(holdtime),shiftedout(size),orcleared.
Thetraceroute(linktrace)isimplementedasanondemandutilitythatismanuallyinvoked
whennecessaryfortestingortroubleshootingthenetwork.Thetraceroutefunctioncanbe
invokedthroughtheCLIorSNMP.WheninvokedthroughCLI,theresultsaredisplayed
directlyonthescreenandstoredinthetraceroutecache.WheninvokedthroughSNMP,the
resultsarestoredinthetraceroutecachesotheSNMPmanagercancollecttheresults.Usethe
noformofthiscommandtoreturnholdtimetothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmtraceroutecacheholdtime<1
65535>command.
(config)#ethernet cfm traceroute cache hold-time 200
(config)#

Functional Notes
Thevalidrangefortheholdtimeis1to65535.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45172

6TANV57CLI-35A

2-1711

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm traceroute cache hold-time <1-65535> size <14095>


Usetheethernetcfmtraceroutecacheholdtime<165535>size<14095>commandtoadjust
thetraceroutecachetimeoutandsize.WhenaMEPperformsatraceroute,theresultsare
addedtothetraceroutecachewheretheresultsarestoreduntiltimedout(holdtime),shifted
out(size),orcleared.Thetraceroute(linktrace)isimplementedasanondemandutilitythatis
manuallyinvokedwhennecessaryfortestingortroubleshootingthenetwork.Thetraceroute
functioncanbeinvokedthroughtheCLIorSNMP.WheninvokedthroughCLI,theresultsare
displayeddirectlyonthescreenandstoredinthetraceroutecache.Wheninvokedthrough
SNMP,theresultsarestoredinthetraceroutecachesotheSNMPmanagercancollectthe
results.Usethenoformofthiscommandtoreturnholdtimeandsizetothedefaultvalues.

Syntax Description
<165535>

Enterholdtimeinminutes

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmtraceroutecacheholdtime<1
65535>size<14095>command.
(config)#ethernet cfm traceroute cache hold-time 200 size 100
(config)#

Functional Notes
Usethe<165535>inputtodesignatetheholdtime.Thevalidrangefortheholdtimeis1
65535.
Thevalidrangeforthenumberofentriesis14095.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45174

2-1712

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet cfm traceroute cache size <1-4095>


Usetheethernetcfmtraceroutecachesize<14095>commandtoadjustthetraceroutecache
size.WhenaMEPperformsatraceroute,theresultsareaddedtothetraceroutecachewhere
theresultsarestoreduntiltimedout(holdtime),shiftedout(size),orcleared.Thetraceroute
(linktrace)isimplementedasanondemandutilitythatismanuallyinvokedwhennecessary
fortestingortroubleshootingthenetwork.Thetraceroutefunctioncanbeinvokedthrough
theCLIorSNMP.WheninvokedthroughCLI,theresultsaredisplayeddirectlyonthescreen
andstoredinthetraceroutecache.WheninvokedthroughSNMP,theresultsarestoredinthe
traceroutecachesotheSNMPmanagercancollecttheresults.Usethenoformofthis
commandtoreturnsizetothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmtraceroutecachesize<14095>
command.
(config)#ethernet cfm traceroute cache size 200
(config)#

Functional Notes
Thevalidrangeforthenumberofentriesis1to4095.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
45176

6TANV57CLI-35A

2-1713

Total Access/NetVanta Carrier CLI Dictionary

ethernet default interface efm-group [<shelf/slot/


group>|WORD]
Usethiscommandtoconfigurethedefualtnetworkinterfaceforsubscribetraffictobethe
specifedefmgroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
61941

2-1714

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet default interface erps <shelf/slot/ring>


Usethiscommandtoconfigurethedefualtnetworkinterfaceforsubscribetraffictobethe
specifedERPSinterface.

Functional Notes
entrypointintoethernetcommandset.Needindexasargtochance
<index>

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
64955

6TANV57CLI-35A

2-1715

Total Access/NetVanta Carrier CLI Dictionary

ethernet default interface gigabit-ethernet <shelf/slot/port>


Usetheethernetdefaultinterfacegigabitethernet<shelf/slot/port>commandtoconfigure
specifiedGigabitEthernetinterfacetobethedefaultnetworkinterfaceforsubscribertraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetdefaultinterfacegigabitethernet
<shelf/slot/port>command.
(config)#ethernet default interface gigabit-ethernet 1/0/3
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
61923

2-1716

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet default interface lag-group [<shelf/slot/


group>|WORD]
Usetheethernetdefaultinterfacelaggroup<shelf/slot/group>commandtoconfigurethe
specifiedlaggrouptobethedefaultnetworkinterfaceforsubscribertraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetdefaultinterfacelaggroup[<shelf/slot/
group>|WORD]command.
(config)#ethernet default interface lag-group 1/0/3
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83129

6TANV57CLI-35A

2-1717

Total Access/NetVanta Carrier CLI Dictionary

ethernet default interface rpr <shelf/slot/ring>


Usethiscommandtoconfigurethedefualtnetworkinterfaceforsubscribetraffictobethe
specifedERPSinterface.

Functional Notes
entrypointintoethernetcommandset.Needindexasargtochance
<index>

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187025G2),SM10GE(1187030G1)

Command ID
93624

2-1718

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet default interface ten-gigabit-ethernet <shelf/slot/port>


Usethiscommandtoconfigurethedefualtnetworkinterfaceforsubscribetraffictobethe
specifedtengigabitethernetinterface.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
61950

6TANV57CLI-35A

2-1719

Total Access/NetVanta Carrier CLI Dictionary

ethernet internal-system-s-tag <2-4094>


UsetheethernetinternalsystemstagcommandtosettheInternalManagement/DataVLAN.
TheInternalManagement/DataVLANisthecommonVLANVIDthatisusedforallsystem
intercommunicationwhichincludesmanagementprotocolsandintercarddatasuchasVoice
Gateway/POTS,AnyportEFMBondingandATMtransportbetweencards.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetinternalsystemstag<24094>
command.
(config)#ethernet internal-system-s-tag 1
(config)#

Functional Notes
ThevalidrangefortheStagis2to4094.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
67120

2-1720

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ethernet s-tag-tpid HHHH


UsetheethernetstagtpidHHHHcommandtospecifytheTagProtocolIdentifier(TPID)
usedonallappliedstags.

Usage Examples
ThefollowingisanexampleofhowtousetheethernetstagtpidHHHHcommand.
(config)#ethernet s-tag-tpid 8100
(config)#

Functional Notes
ThevalidrangefortheTPIDis0x08000xFFFF.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
46614

6TANV57CLI-35A

2-1721

Total Access/NetVanta Carrier CLI Dictionary

evc WORD
UsetheevcWORDcommandtoactivatetheEVCInterfaceConfigurationCommandSet.If
theEVCdoesnotexist,anewoneiscreatedwithdefaultparameters.

Usage Examples
ThefollowingisanexampleofhowtousetheevcWORDcommand.
(config)#evc myEVC
(config-evc myEVC)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
64488

2-1722

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

evc-map WORD
UsetheevcmapWORDcommandtoactivatetheEVCMapInterfaceConfiguration
CommandSet.IftheEVCmapdoesnotexist,anewoneiscreatedwithdefaultparameters.

Usage Examples
ThefollowingisanexampleofhowtousetheevcmapWORDcommand.
(config)#evc-map myEVCMap
(config-evc-map myEVCMap)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),TA3002POTS2GE
(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA334
2POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GE
HPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64490

6TANV57CLI-35A

2-1723

Total Access/NetVanta Carrier CLI Dictionary

evc-map WORD <shelf/slot>


UsetheevcmapWORD<shefl/slot>commandtoactivatetheEVCMapInterfaceConfigu
rationCommandSet.IftheEVCmapdoesnotexist,anewoneiscreatedwithdefaultparam
eters.

Syntax Description
WORD

Nameoftrafficclassifier

Usage Examples
ThefollowingisanexampleofhowtousetheevcmapWORD<shelf/slot>command.
(config)#evc-map map110 1/9
(config-evc-map MAP110)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3
PPPAM(1187220G1),ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM
(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitter
Comp(1187102G1),E1CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),
QuadGPONAM(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3Frame
Relay3PortAM(1187220G3),10GEthernetMuxponder(1174101F1),TA3002POTS2GE
(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA334
2POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GE
HPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89444

2-1724

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

event-log-export
UsetheeventlogexportcommandtoactivatetheEventLogConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousetheeventlogexportcommand.
(config)#event-log-export
(config-event-log)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77706

6TANV57CLI-35A

2-1725

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.UsageExamplesThefollowingexampleshowstheexitcommandbeing
executedintheGlobalConfigurationmode:(config)#exit##EnableSecuritymodecommand
prompt

Functional Notes
Theexitcommandhasnosubcommands.Theexitcommandhasnodefaultvalues.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),SCM
(1188010E1),SCM(1187010L1),SCMG2(1187010G2),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-1726

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

Command ID
64387

6TANV57CLI-35A

2-1727

Total Access/NetVanta Carrier CLI Dictionary

ez-provisioning
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
139870

2-1728

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

fan <shelf/slot>
Usethefan<shelf/slot>commandtoactivatetheFanConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethefan<shelf/slot>command.
(config)#fan 1/F
(config-fan 1/F)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV824(1200634G4),NV828(1200634G2),NV844
(1200635G2)

Command ID
87680

6TANV57CLI-35A

2-1729

Total Access/NetVanta Carrier CLI Dictionary

fxs battery-remove
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),VDSL2Combo24PAM(1187120L1)

Command ID
102013

2-1730

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

fxs battery-remove <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),VDSL2Combo24PAM(1187120L1)

Command ID
102014

6TANV57CLI-35A

2-1731

Total Access/NetVanta Carrier CLI Dictionary

interface adsl <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),ADSLAMwithVDSLSplitterComp(1187102G1)

Command ID
91683

2-1732

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface atm [<shelf/slot/port>|<shelf/slot/port.sub>]


UsetheinterfaceATM<shelf/slot/port>commandtoactivatetheATMInterfaceConfiguration
CommandSetforthespecifiedshelf,slot,andport.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceatm[<shelf/slot/port>|<shelf/slot/
port.sub>]command.
(config)#interface atm 1/3/1.1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
87835

6TANV57CLI-35A

2-1733

Total Access/NetVanta Carrier CLI Dictionary

interface atm-group <shelf/slot/group> legacy-atm


Syntax Description
<shelf/slot/group>

Specifiedgroup

Functional Notes
Usetheinterfaceatmgroup<shelf/slot/group>commandtocreateanATMGrouponthe
specifiedslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L2),VDSL2
Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp
(1187102G1)

Command ID
150693

2-1734

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface e1 <shelf/slot/port>
Usetheinterfacee1<shelf/slot/port>commandtoactivatetheE1InterfaceConfiguration
CommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacee1<shelf/slot/port>command.
(config)#interface e1 1/0/1
(config-e1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFME1AM(1188802G1),E1INTLPPPAM(1188803G2),E1CEM32PortAM(1188801G1),
NV814(1200637G4),NV818(1200637G2)

Command ID
45673

6TANV57CLI-35A

2-1735

Total Access/NetVanta Carrier CLI Dictionary

interface efm-group [<shelf/slot/group>|WORD]


Usetheinterfaceefmgroup<shelf/slot/group>commandtoactivatetheEFMGroupInterface
ConfigurationCommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceefmgroup[<shelf/slot/
group>|WORD]command.
(config)#interface efm-group 1/0/1
(config-efm-group 1/0/1)#

Functional Notes
TocreateanEFMgroup,the<shelf/slot/group>inputmustbespecified.Oncecreated,analias
canbeusedtoconfigurethegroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
58294

2-1736

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface efm-link [<shelf/slot/port>|<shelf/slot/port:chan>]


Usetheinterfaceefmlink<shelf/slot/port>commandtoactivatetheEFMLinkInterface
ConfigurationCommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceefmlink[<shelf/slot/port>|<shelf/slot/
port:chan>]command.
(config)#interface efm-link 1/0/1
(config-efm-link 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
58296

6TANV57CLI-35A

2-1737

Total Access/NetVanta Carrier CLI Dictionary

interface efm-port <shelf/slot/port>


Usetheinterfaceefmport<shelf/slot/port>commandtoactivatetheEFMPortInterface
ConfigurationCommandSetforthespecifiedshelf,slot,andport.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceefmport<shelf/slot/port>command.
(config)#interface efm-port 1/9/1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
64506

2-1738

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface erps <shelf/slot/ring>


Usetheinterfaceerps<shelf/slot/ring>commandtoactivatetheERPSInterfaceConfiguration
CommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceerps<shelf/slot/ring>command.
(config)#interface erps 1/0/4
(config-erps 1/0/4)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67056

6TANV57CLI-35A

2-1739

Total Access/NetVanta Carrier CLI Dictionary

interface ethernet <shelf/slot/port>


Usetheinterfaceethernet<shelf/slot/port>commandtoactivatetheEthernetInterfaceConfig
urationCommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceethernet<shelf/slot/port>command.
(config)#interface ethernet 1/0/2
(config-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
16032

2-1740

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface frame-relay <shelf/slot/group>


Functional Notes
Usetheinterfaceframerelay<shelf/slot/group>commandtocreate?aFrameRelayGroupon
thespecifiedslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133665

6TANV57CLI-35A

2-1741

Total Access/NetVanta Carrier CLI Dictionary

interface frame-relay <shelf/slot/group> dlci <16-991>


Syntax Description
<shelf/slot/group>

Specifiedgroupnumber

Functional Notes
Usetheinterfaceframerelay<shelf/slot/group>commandtoactivatethe?Frame
Relay?PVC?InterfaceConfigurationCommandSetforthespecifiedinterface.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
133688

2-1742

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface fxs [<shelf/slot/port>|<remote-index>]


Usetheinterfacefxs<shelf/slot/port>commandtoactivatetheFXSInterfaceConfiguration
CommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacefxs[<shelf/slot/port>|<remoteindex>]
command.
(config)#interface fxs 1/0/1
(config-fxs 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
96559

6TANV57CLI-35A

2-1743

Total Access/NetVanta Carrier CLI Dictionary

interface gigabit-ethernet [<shelf/slot/port>|<remote-index>]


Usetheinterfacegigabitethernet<shelf/slot/port>commandtoactivatetheGigabitEthernet
InterfaceConfigurationCommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacegigabitethernet[<shelf/slot/
port>|<remoteindex>]command.
(config)#interface gigabit-ethernet 1/0/1
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),TA300
2POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE
(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44627

2-1744

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface gpon <shelf/slot/port>


Usetheinterfacegpon<shelf/slot/port>commandtoactivatetheGPONInterfaceConfigu
rationCommandSetforthespecifiedinterface.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136538

6TANV57CLI-35A

2-1745

Total Access/NetVanta Carrier CLI Dictionary

interface hdsl2 <shelf/slot/port>


Usetheinterfacehdsl2commandtoactivatetheHDSL2InterfaceCommandSetforthe
specifiedphysicalinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacehdsl2<shelf/slot/port>command.
(config)#interface hdsl2 1/0/1
(config-hdsl2 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43906

2-1746

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface hdsl4 <shelf/slot/port>


Usetheinterfacehdsl4commandtoactivatetheHDSL4InterfaceCommandSetforthe
specifiedphysicalinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacehdsl4<shelf/slot/port>command.
(config)#interface hdsl4 1/0/1
(config-hdsl4 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
43908

6TANV57CLI-35A

2-1747

Total Access/NetVanta Carrier CLI Dictionary

interface ip-host WORD [<shelf/slot>|<remote-index>]


Syntax Description
WORD

SpecifiedIPHost

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
95792

2-1748

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface lag-group [<shelf/slot/group>|WORD]


Usetheinterfacelaggroup<shelf/slot/group>commandtocreatealinkaggregationgroup
forthespecifiedslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83123

6TANV57CLI-35A

2-1749

Total Access/NetVanta Carrier CLI Dictionary

interface muxponder-highspeed <shelf/slot/interface> tengigabit-ethernet


Syntax Description
<shelf/slot/interface>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135960

2-1750

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface muxponder-midspeed <shelf/slot/interface> gigabitethernet


Syntax Description
<shelf/slot/interface>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135957

6TANV57CLI-35A

2-1751

Total Access/NetVanta Carrier CLI Dictionary

interface packet-timing <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144149

2-1752

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface ppp-group [<shelf/slot/group>|WORD]


Usetheinterfacepppgroup<shelf/slot/group>commandtocreateaPPPGrouponthe
specifiedslot..

Functional Notes
thiscommandputstheuserintothepppgroupcommandset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89281

6TANV57CLI-35A

2-1753

Total Access/NetVanta Carrier CLI Dictionary

interface pseudowire [<shelf/slot/pwe>|<remote-index>] cem


Syntax Description
<shelf/slot/pwe>

Specifiedinterface

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
133172

2-1754

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface rf-video <remote-index>


Functional Notes
SwitchtointerfaceRFVideocommandSet

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3612POTS1GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2
POTS1GE1FESWRDRF(1187712G2),TA3652POTS1GERFRFoG,TA3612
POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2POTS2
GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
144610

6TANV57CLI-35A

2-1755

Total Access/NetVanta Carrier CLI Dictionary

interface shdsl <shelf/slot/port>


Usetheinterfaceshdsl<shelf/slot/port>commandtoactivatetheSHDSLInterfaceConfigu
rationCommandSetforthespecifiedinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfaceshdsl<shelf/slot/port>command.
(config)#interface shdsl 1/0/1
(config-shdsl 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
16360

2-1756

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface t1 [<shelf/slot/port>|<shelf/slot/port:chan>]
Usetheinterfacet1commandtoactivatetheT1InterfaceCommandSetforthespecified
physicalinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacet1[<shelf/slot/port>|<shelf/slot/
port:chan>]command.
(config)#interface t1 1/0/1
(config-t1 1/0/1)#

Functional Notes
The<shelf/slot/port>inputisusedforDS1cards.
The<shelf/slot/port:chan>inputisusedforchannelizedDS3cards.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45702

6TANV57CLI-35A

2-1757

Total Access/NetVanta Carrier CLI Dictionary

interface t3 <shelf/slot/port>
Usetheinterfacet3commandtoactivatetheT3InterfaceCommandSetforthespecified
physicalinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacet3<shelf/slot/port>command.
(config)#interface t3 1/0/1
(config-t3 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42695

2-1758

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

interface ten-gigabit-ethernet <shelf/slot/port>


Usetheinterfacetengigabitethernet*commandtoentertheTenGigabitEthernetport
number.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65078

6TANV57CLI-35A

2-1759

Total Access/NetVanta Carrier CLI Dictionary

interface vdsl <shelf/slot/port>


Usetheinterfacevdsl<shelf/slot/port>commandtoactivatetheVDSLInterfaceConfiguration
CommandSetforthespecifiedphysicalinterface.Thiscommandsetmodifiesprovisioning
andperformancecharacteristicoftheVDSLinterface.

Usage Examples
Thefollowingisanexampleofhowtousetheinterfacevdsl<shelf/slot/port>command.
(config)#interface vdsl 1/19/1
(config-vdsl 1/19/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
19200

2-1760

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip [domain-lookup|forwarding|syslog]
Usetheip[domainlookup|forwarding|syslog]commandtospecifyalternateTransmission
ControlProtocol(TCP)portsforsecureshell(SSH)andTelnetservers.SSHisanewerversion
ofTelnetthatallowscommandlineandgraphicalapplications(aswellas,filetransfers)over
anencryptedconnection.Usethenoformofthiscommandtoreturntodefaultsettings.

Syntax Description
domainlookup

EnableIPDomainNameSystemhostnametranslation

forwarding

EnableIPforwarding

syslog

Enablesyslog

Usage Examples
Thefollowingisanexampleofhowtousetheip[domainlookup|forwarding|syslog]
command.
(config)#ip domain-lookup
(config)#

Functional Notes
Usethedomainlookupoptiontoenabledomainnametranslation.
UsetheforwardingoptiontoenableIPforwarding.
Usethesyslogoptiontoenablethesystemlog.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
44911

6TANV57CLI-35A

2-1761

Total Access/NetVanta Carrier CLI Dictionary

ip access-list standard WORD


UsetheipaccessliststandardWORDcommandtocreateanemptyaccesscontrollist(ACL)
andtoactivatetheIPACLConfigurationCommandSet.Usethenoformofthiscommandto
deleteanACLentry.

Usage Examples
ThefollowingisanexampleofhowtousetheipaccessliststandardWORDcommand.
(config)#ip access-list standard listname
(config-mgmt-acl listname)#

Functional Notes
Bydefault,noACLsareconfigured.Onlyonelistattimeispermitted.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64129

2-1762

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip default-gateway A.B.C.D
UsetheipdefaultgatewayA.B.C.DcommandtosettheIPaddressofthedefaultgateway.

Usage Examples
ThefollowingisanexampleofhowtousetheipdefaultgatewayA.B.C.Dcommand.
(config)#ip default-gateway 192.168.1.254
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44920

6TANV57CLI-35A

2-1763

Total Access/NetVanta Carrier CLI Dictionary

ip domain-name-list LINE
UsetheipdomainnamelistLINEcommandtodefinealistofdefaultdomainnames.

Usage Examples
ThefollowingisanexampleofhowtousetheipdomainnamelistLINEcommand.
(config)#ip domain-name-list www.adtran.com
(config)#

Functional Notes
UsetheLINEinputtodefinealistofdefaultdomainnamesusingaspacetoseparateeach
name.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64029

2-1764

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server auto-upgrade filename WORD


UsetheipfileserverautoupgradefilenameWORDcommandtoconfiguretheautoupgrade
filename.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverautoupgradefilenameWORD
command.
(config)#ip file-server auto-upgrade filename autoupgrade.auc
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
84586

6TANV57CLI-35A

2-1765

Total Access/NetVanta Carrier CLI Dictionary

ip file-server auto-upgrade path WORD


UsetheipfileserverautoupgradepathWORDcommandtoconfiguretheremoteauto
upgradepath.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverautoupgradepathWORD
command.
(config)#ip file-server auto-upgrade path pathname
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
84584

2-1766

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server default filename WORD


UsetheipfileserverdefaultfilenameWORDcommandtoenterthedefaultfilenameforfile
transfers.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverdefaultfilenameWORD
command.
(config)#ip file-server default filename flash.bin
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
66026

6TANV57CLI-35A

2-1767

Total Access/NetVanta Carrier CLI Dictionary

ip file-server default host A.B.C.D


UsetheipfileserverdefaulthostA.B.C.DcommandtoenteranIPhostforfiletransfers.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverdefaulthostA.B.C.Dcommand.
(config)#ip file-server default host 192.168.1.1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
66021

2-1768

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server default path WORD


UsetheipfileserverdefaultpathWORDcommandtoenteradefaultpathforfiletransfers.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverdefaultpathWORDcommand.
(config)#ip file-server default path pathname
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66024

6TANV57CLI-35A

2-1769

Total Access/NetVanta Carrier CLI Dictionary

ip file-server default protocol [file-transfer-over-tl1|ftp|sftp|tftp]


Usetheipfileserverdefaultprotocol[filetransferovertl1|ftp|sftp|tftp]commandtoassign
adefaultprotocoltouseforfiletransfers.

Syntax Description
filetransferovertl1

FiletransferoverTL1

ftp

FTP

sftp

SecureFTP

tftp

TFTP

Usage Examples
Thefollowingisanexampleofhowtousetheipfileserverdefaultprotocol[filetransfer
overtl1|ftp|sftp|tftp]command.
(config)#ip file-server protocol tftp
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66056

2-1770

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server default username WORD


UsetheipfileserverdefaultusernameWORDcommandtoenteradefaultusernameforfile
transfers.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverdefaultusernameWORD
command.
(config)#ip file-server default username myname
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66090

6TANV57CLI-35A

2-1771

Total Access/NetVanta Carrier CLI Dictionary

ip file-server default username WORD password


UsetheipfileserverdefaultusernameWORDpasswordcommandtoenterapasswordfor
filetransfers.

Syntax Description
WORD

Enterusername

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverdefaultusernameWORD
passwordcommand.
(config)#ip file-server default username myname password
Password: ****
(config)#

Functional Notes
UsetheWORDinputtoenterastringwithoutspaces.Thisinputisnotcasesensitive.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66091

2-1772

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server download-cache expire <60-1440>


Usetheipfileserverdownloadcacheexpire<601440>commandtosetanexpirationtimeout
forfiletransfers.

Usage Examples
Thefollowingisanexampleofhowtousetheipfileserverdownloadcacheexpire<601440>
command.
(config)#ip file-server download-cache expire 1440
(config)#

Functional Notes
Thevalidrangeforthetimeoutis60to1440seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66089

6TANV57CLI-35A

2-1773

Total Access/NetVanta Carrier CLI Dictionary

ip file-server event-log-export host A.B.C.D


UsetheipfileservereventlogexporthostA.B.C.DcommandtoentertheIPaddressforthe
eventlogexports.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileservereventlogexporthostA.B.C.D
command.
(config)#ip file-server event-log-export host 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66105

2-1774

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server event-log-export path WORD


UsetheipfileservereventlogexportpathWORDcommandtoenterthethepathforevent
logexports.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileservereventlogexportpathWORD
command.
(config)#ip file-server event-log-export path mypath
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66107

6TANV57CLI-35A

2-1775

Total Access/NetVanta Carrier CLI Dictionary

ip file-server general-export host A.B.C.D


UsetheipfileservergeneralexporthostA.B.C.DcommandtoentertheIPaddressforthefile
serverforgeneralexports.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileservergeneralexporthostA.B.C.D
command.
(config)#ip file-server general-export host 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66110

2-1776

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server general-export path WORD


UsetheipfileservergeneralexportpathWORDcommandtoenterthepathforthefileserver
forgeneralexports.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileservergeneralexportpathWORD
command.
(config)#ip file-server general-export path mypath
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
84588

6TANV57CLI-35A

2-1777

Total Access/NetVanta Carrier CLI Dictionary

ip file-server general-export retries <0-2>


Usetheipfileservergeneralexportretries<02>commandtosetthenumberofexportretries
tothefileserverforgeneralexports.

Usage Examples
Thefollowingisanexampleofhowtousetheipfileservergeneralexportretries<02>
command.
(config)#ip file-server general-export retries 2
(config)#

Functional Notes
Thevalidrangeforthenumberofretriesis0to2.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
84591

2-1778

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server sca filename WORD


UsetheipfileserverscafilenameWORDcommandtoconfiguretheremoteSCAfilename.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverscafilenameWORDcommand.
(config)#ip file-server sca filename scafile.sca
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66115

6TANV57CLI-35A

2-1779

Total Access/NetVanta Carrier CLI Dictionary

ip file-server sca host A.B.C.D


UsetheipfileserverscahostA.B.C.DcommandtoconfiguretheremoteSCAhost.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserverscahostA.B.C.Dcommand.
(config)#ip file-server sca host 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66117

2-1780

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip file-server sys-log-export host A.B.C.D


UsetheipfileserversyslogexporthostA.B.C.DcommandtoentertheIPaddressforthe
systemlogexporthost.

Usage Examples
ThefollowingisanexampleofhowtousetheipfileserversyslogexporthostA.B.C.D
command.
(config)#ip file-server sys-log-export host 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66113

6TANV57CLI-35A

2-1781

Total Access/NetVanta Carrier CLI Dictionary

ip igmp evc WORD <shelf/slot> mode


[proxy|snooping|transparent]
Syntax Description
WORD

NameofEVC

<shelf/slot>

Specifiedslot

proxy

ProxyIGMPmessages

snooping

SnoopIGMPmessages

transparent

PassIGMPmessagestransparently

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
93949

2-1782

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip igmp evc WORD <shelf/slot> proxy host ip address A.B.C.D


Syntax Description
WORD

NameofEVC

<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
93635

6TANV57CLI-35A

2-1783

Total Access/NetVanta Carrier CLI Dictionary

ip igmp evc WORD <shelf/slot> proxy last-member-query


count <1-255>
Syntax Description
WORD

NameofEVC

<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
93638

2-1784

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip igmp evc WORD <shelf/slot> proxy last-member-query


interval <100-65535>
Syntax Description
WORD

NameofEVC

<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
93640

6TANV57CLI-35A

2-1785

Total Access/NetVanta Carrier CLI Dictionary

ip name-server primary A.B.C.D


UsetheipnameserverprimaryA.B.C.DcommandtoentertheIPaddressfortheprimary
server.

Usage Examples
ThefollowingisanexampleofhowtousetheipnameserverprimaryA.B.C.Dcommand.
(config)#ip name-server primary 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64039

2-1786

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip name-server secondary A.B.C.D


UsetheipnameserversecondaryA.B.C.DcommandtoentertheIPaddressforthesecondary
server.

Usage Examples
ThefollowingisanexampleofhowtousetheipnameserversecondaryA.B.C.Dcommand.
(config)#ip name-server secondary 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64042

6TANV57CLI-35A

2-1787

Total Access/NetVanta Carrier CLI Dictionary

ip ntp server A.B.C.D prefer


UsetheipntpserverA.B.C.DprefercommandtospecifytheNTPserverthatispreferred
aboveallotherservers.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousetheipntpserverA.B.C.Dprefercommand.
(config)#ip ntp server 192.168.1.1 prefer
(config)#

Functional Notes
UsetheA.B.C.DinputtosettheIPaddressforthepreferredNTPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46400

2-1788

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ntp server A.B.C.D prefer version <3-4>


UsetheipntpserverA.B.C.Dpreferversion<34>commandtospecifytheNTPserverthatis
preferredaboveallotherserversandtheNTPversiontouse.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousetheipntpserverA.B.C.Dpreferversion<34>
command.
(config)#ip ntp server 192.168.1.1 prefer version 3
(config)#

Functional Notes
UsetheA.B.C.DinputtospecifytheIPaddressforthepreferredNTPserver.
Thevalidrangefortheversionis3to4.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46402

6TANV57CLI-35A

2-1789

Total Access/NetVanta Carrier CLI Dictionary

ip ntp server A.B.C.D version <3-4>


UsetheipntpserverA.B.C.Dversion<34>commandtospecifytheNTPserverandtheNTP
versiontouse.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousetheipntpserverA.B.C.Dversion<34>command.
(config)#ip ntp server 192.168.1.1 version 3
(config)#

Functional Notes
UsetheA.B.C.DinputtodesignatetheIPaddressfortheselectedNTPserver.
Thevalidrangefortheversionis3to4.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46398

2-1790

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ntp server A.B.C.D version <3-4> prefer


UsetheipntpserverA.B.C.Dversion<34>prefercommandtodesignatewhichserveris
preferredaboveallotherserversandtheNTPversiontouse.

Syntax Description
A.B.C.D

IPaddress

<34>

Versionnumber

Usage Examples
ThefollowingisanexampleofhowtousetheipntpserverA.B.C.Dversion<34>prefer
command.
(config)#ip ntp server 192.168.1.1 version 3 prefer
(config)#

Functional Notes
UsetheA.B.C.DinputtosettheIPaddressforthepreferredserver.
Thevalidrangefortheversionis3to4.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46399

6TANV57CLI-35A

2-1791

Total Access/NetVanta Carrier CLI Dictionary

ip power-shedding remote-server A.B.C.D


Usetheipfileservercommandtoconfigurethefiletransferserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
140448

2-1792

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip raw-tl1 [server|tcp-dead-client]
Usetheiprawtl1[server|tcpdeadclient]commandtoenabletherawTL1serverandsetthe
TCPportortoenableRFC1122deadclientdetection.

Syntax Description
server

EnabletherawTL1serverwiththedefaultTCPport

tcpdeadclient

EnableRFC1122TCPdeadclientdetection

Usage Examples
Thefollowingisanexampleofhowtousetheiprawtl1[server|tcpdeadclient]command.
(config)#ip raw-tl1 server
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65494

6TANV57CLI-35A

2-1793

Total Access/NetVanta Carrier CLI Dictionary

ip raw-tl1 server <1024-65535>


Usetheiprawtl1server<102465535>commandtoenabletherawTL1serverwiththe
specifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheiprawtl1server<102465535>command.
(config)#ip raw-tl1 server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65496

2-1794

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip raw-tl1 server <1024-65535> ssh


Usetheiprawtl1server<102465535>sshcommandtoenablethesecondarytelnetserver
withthespecifiedTCPport.

Syntax Description
<102465535>

EnabletherawTL1serverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheiprawtl1server<102465535>sshcommand.
(config)#ip raw-tl1 server 1024 ssh
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87811

6TANV57CLI-35A

2-1795

Total Access/NetVanta Carrier CLI Dictionary

ip route A.B.C.D A.B.C.D A.B.C.D


UsetheiprouteA.B.C.DA.B.C.DA.B.C.Dcommandtocreatearouteintheroutetable.Use
thenoformofthiscommandtoremovetheroutefromtheroutetable.

Syntax Description
A.B.C.D

IPnetworkaddress

A.B.C.D

IPsubnetmask

Usage Examples
ThefollowingisanexampleofhowtousetheiprouteA.B.C.DA.B.C.DA.B.C.Dcommand.
(config)#ip route 10.100.38.95 255.255.255.0 10.100.38.254
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
88408

2-1796

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip rtp udp <1026-60000>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
127946

6TANV57CLI-35A

2-1797

Total Access/NetVanta Carrier CLI Dictionary

ip snmp agent
UsetheipsnmpagentcommandtoenabletheSNMPagent.Usethenoformofthiscommand
todisabletheagent.

Usage Examples
Thefollowingisanexampleofhowtousetheipsnmpagentcommand.
(config)#ip snmp agent
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
87666

2-1798

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip sntp refresh-period <1-60>


Usetheipsntprefreshperiod<160>commandtoconfiguretheamountoftimebetween
clockupdates.Usethenoformofthiscommandtosettherefreshperiodtothedefault.

Usage Examples
Thefollowingisanexampleofhowtousetheipsntprefreshperiod<160>command.
(config)#ip sntp refresh-period 60
(config)#

Functional Notes
Therefreshperiodisupdatedtothenearestfiveminuteinterval.Aninputoflessthan3
changesto1.Forexample,aninputof0fortherefreshintervalissetto1,andaninputof3is
setto5.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87217

6TANV57CLI-35A

2-1799

Total Access/NetVanta Carrier CLI Dictionary

ip sntp server A.B.C.D


UsetheipsntpserverA.B.C.DcommandtosettheIPaddresstotheSNTPhostserverandto
enableSNTPmode.UsethenoformofthiscommandtosettheIPaddresstothedefaultand
disableSNTP.

Usage Examples
ThefollowingisanexampleofhowtousetheipsntpserverA.B.C.Dcommand.
(config)#ip sntp server 1.2.3.4
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
82755

2-1800

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ssh [server|tunnels]
Usetheipssh[server|tunnels]commandtoenabletheSSHserverandsettheTCPportorto
enabletheuseofSSHtunnels.

Syntax Description
server

EnabletheSSHserverwiththedefaultTCPport

tunnels

EnableSSHtunnels

Usage Examples
Thefollowingisanexampleofhowtousetheipssh[server|tunnels]command.
(config)#ip ssh tunnels
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65506

6TANV57CLI-35A

2-1801

Total Access/NetVanta Carrier CLI Dictionary

ip ssh key size <512-2048>


Usetheipsshkeysize<5122048>commandtomodifytheSSHkeysize.

Usage Examples
Thefollowingisanexampleofhowtousetheipsshkeysize<5122048>command.
(config)#ip ssh key size 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63553

2-1802

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ssh server <1024-65535>


Usetheipsshserver*commandtoenabletheSSHserverwiththespecifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheipsshserver<102465535>command.
(config)#ip ssh server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65508

6TANV57CLI-35A

2-1803

Total Access/NetVanta Carrier CLI Dictionary

ip ssh-tl1 server
Usetheipsshtl1servercommandtoenabletheTL1SSHserveranddefaulttheTCPport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65501

2-1804

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ssh-tl1 server <1024-65535>


Usetheipsshtl1server*commandtoenabletheTL1SSHserverwiththespecifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheipsshtl1server<102465535>command.
(config)#ip ssh-tl1 server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65502

6TANV57CLI-35A

2-1805

Total Access/NetVanta Carrier CLI Dictionary

ip ssh-tl1-secondary server
Usetheipsshtl1secondaryservercommandtoenablethesecondaryTL1SSHserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65504

2-1806

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip ssh-tl1-secondary server <1024-65535>


Usetheipsshtl1secondaryserver*commandtoenablethesecondaryTL1SSHserverwith
thespecifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheipsshtl1secondaryserver<102465535>
command.
(config)#ip ssh-tl1-secondary server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65505

6TANV57CLI-35A

2-1807

Total Access/NetVanta Carrier CLI Dictionary

ip telnet [dead-client|server]
UsetheiptelnetcommandtospecifytheTCPportnumbertobeusedwhenconnectingtoa
hostthroughTelnetortoenabledeadclientdetection.

Syntax Description
deadclient

Enabletelnetdeadclientdetection

server

EnablethetelnetserverwiththedefaultTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnet[deadclient|server]command.
(config)#ip telnet dead-client
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65497

2-1808

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip telnet mode [cli|menus]


UsetheiptelnetservercommandtoenabletheTelnetserverwiththedefaultTCPport.

Syntax Description
cli

SetthetelnetmodetoCLI

menus

Setthetelnetmodetomenus

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
117429

6TANV57CLI-35A

2-1809

Total Access/NetVanta Carrier CLI Dictionary

ip telnet server <1024-65535>


Usetheiptelnetserver*commandtoenabletheTelnetserverwithaspecifieddefaultTCP
port.

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnetserver<102465535>command.
(config)#ip telnet server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65499

2-1810

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip telnet server <1024-65535> ssh


Usetheiptelnetsecondaryserver*commandtoenablethesecondarytelnetserverwiththe
specifiedTCPport.

Syntax Description
<102465535>

EnablethetelnetserverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnetserver<102465535>sshcommand.
(config)#ip telnet server 1024 ssh
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87812

6TANV57CLI-35A

2-1811

Total Access/NetVanta Carrier CLI Dictionary

ip telnet-secondary mode [cli|menus]


UsetheiptelnetservercommandtoenabletheTelnetserverwiththedefaultTCPport.

Syntax Description
cli

SetthesecondarytelnetmodetoCLI

menus

Setthesecondarytelnetmodetomenus

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
117432

2-1812

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip telnet-secondary server
Usetheiptelnetsecondaryservercommandtoenablethesecondarytelnetserveranddefault
theTCPport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65489

6TANV57CLI-35A

2-1813

Total Access/NetVanta Carrier CLI Dictionary

ip telnet-secondary server <1024-65535>


Usetheiptelnetsecondaryserver<102465535>commandtoenablethesecondarytelnet
serverwiththespecifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnetsecondaryserver<102465535>
command.
(config)#ip telnet-secondary server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65490

2-1814

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip telnet-secondary server <1024-65535> ssh


Usetheiptelnetsecondaryserver<102465535>sshcommandtoenablethesecondarytelnet
serverwiththespecifiedTCPport.

Syntax Description
<102465535>

EnablethesecondarytelnetserverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnetsecondaryserver<102465535>ssh
command.
(config)#ip telnet-secondary server 1024 ssh
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87809

6TANV57CLI-35A

2-1815

Total Access/NetVanta Carrier CLI Dictionary

ip telnet-tl1 server
Usetheiptelnettl1servercommandtoenabletheTL1telnetserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65492

2-1816

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip telnet-tl1 server <1024-65535>


Usetheiptelnettl1server<102465535>commandtoenabletheTL1telnetserverwiththe
specifiedTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnettl1server<102465535>command.
(config)#ip telnet-tl1 server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65493

6TANV57CLI-35A

2-1817

Total Access/NetVanta Carrier CLI Dictionary

ip telnet-tl1 server <1024-65535> ssh


Usetheiptelnetsecondaryserver<102465535>sshcommandtoenablethesecondarytelnet
serverwiththespecifiedTCPport.

Syntax Description
<102465535>

EnabletheTL1telnetserverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheiptelnettl1server<102465535>sshcommand.
(config)#ip telnet-tl1 server 1024 ssh
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87810

2-1818

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip terminal-server telnet admin [security|server]


UsetheiptelnetadminterminalcommandtoenabletheAdminterminalserverandtosetthe
TCPport.

Syntax Description
security

Enableadminterminalserversecurity

server

EnabletheadminterminalserverwiththedefaultTCPport

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65482

6TANV57CLI-35A

2-1819

Total Access/NetVanta Carrier CLI Dictionary

ip terminal-server telnet admin server <1024-65535>


Usetheipterminalservertelnetadminserver<102465535>commandtoenabletheadmin
terminalserverandtosettheTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheipterminalservertelnetadminserver<1024
65535>command.
(config)#ip terminal-server telnet admin server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65484

2-1820

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip terminal-server telnet admin server <1024-65535> sshtunnel


Usetheterminalservertelnetadminserver<102465535>sshterminalcommandtoenablethe
adminterminalserverandtosettheTCPport.

Syntax Description
<102465535>

EnabletheadminterminalserverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheipterminalservertelnetadminserver<1024
65535>sshtunnelcommand.
(config)#ip terminal-server telnet admin server 1024 ssh-tunnel
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87807

6TANV57CLI-35A

2-1821

Total Access/NetVanta Carrier CLI Dictionary

ip terminal-server telnet network [security|server]


Usetheiptelnetnetworkterminalcommandtoenablethenetworkterminalserverandset
theTCPport.

Syntax Description
security

Enablenetworkportterminalserversecurity

server

EnablethenetworkterminalserverwiththedefaultTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheipterminalservertelnetnetwork
[security|server]command.
(config)#ip terminal-server telnet network server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65485

2-1822

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

ip terminal-server telnet network server <1024-65535>


Usetheipterminalservertelnetnetworkserver<102465535>commandtoenablethe
networkterminalserverandsettheTCPport.

Usage Examples
Thefollowingisanexampleofhowtousetheipterminalservertelnetnetworkserver<1024
65535>command.
(config)#ip terminal-server telnet admin server 1024
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65487

6TANV57CLI-35A

2-1823

Total Access/NetVanta Carrier CLI Dictionary

ip terminal-server telnet network server <1024-65535> sshtunnel


Usetheipterminalservertelnetnetworkserver<102465535>sshtunnelcommandtoenable
thenetworkterminalserverandsettheTCPport.

Syntax Description
<102465535>

EnablethenetworkterminalserverwiththespecifiedTCPport

Usage Examples
Thefollowingisanexampleofhowtousetheipterminalservertelnetnetworkserver<1024
65535>sshtunnelcommand.
(config)#ip terminal-server telnet admin server 1024 ssh-tunnel
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87808

2-1824

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

line admin <0>


Usethelineadmin<0>commandtoactivatetheLineAdminConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethelineadmin<0>command.
(config)#line admin 0
(config-admin0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65370

6TANV57CLI-35A

2-1825

Total Access/NetVanta Carrier CLI Dictionary

line console <0>


Usethelineconsole<0>commandtoactivatetheLineConsoleConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethelineconsole<0>command.
(config)#line console 0
(config-con0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65364

2-1826

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

line network <0>


Usethelinenetwork<0>commandtoactivatetheLineNetworkConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethelinenetwork<0>command.
(config)#line network 0
(config-net0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65368

6TANV57CLI-35A

2-1827

Total Access/NetVanta Carrier CLI Dictionary

line-timeout <0-n>
Usethelinetimeout<0n>commandtospecifythenumberofminutesalinesessioncan
remaininactivebeforethesessionisterminated.

Usage Examples
Thefollowingisanexampleofhowtousethelinetimeout<0n>command.
(config)#line-timeout 15
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64073

2-1828

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

mevc WORD <shelf/slot>


Syntax Description
WORD

Name

Functional Notes
Usethemevc?WORDs/scommandtoactivatethe?MEVCInterfaceConfigurationCommand
Set.IftheMEVCdoesnotexistanewoneiscreatedwithdefaultparameters.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135751

6TANV57CLI-35A

2-1829

Total Access/NetVanta Carrier CLI Dictionary

mode [<shelf/slot>|<remote-index>] voice fxs-signaling


Syntax Description
<shelf/slot>

Specifiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95594

2-1830

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

mode [<shelf/slot>|<remote-index>] voice mgcp


Syntax Description
<shelf/slot>

Specifiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133171

6TANV57CLI-35A

2-1831

Total Access/NetVanta Carrier CLI Dictionary

mode [<shelf/slot>|<remote-index>] voice sip


Syntax Description
<shelf/slot>

Specifiedslot

<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),
TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4GE
(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
95595

2-1832

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146738

6TANV57CLI-35A

2-1833

Total Access/NetVanta Carrier CLI Dictionary

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146739

2-1834

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146740

6TANV57CLI-35A

2-1835

Total Access/NetVanta Carrier CLI Dictionary

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146741

2-1836

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7> <0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146742

6TANV57CLI-35A

2-1837

Total Access/NetVanta Carrier CLI Dictionary

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7> <0-7> <0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146743

2-1838

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7> <0-7> <0-7> <0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe6thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146744

6TANV57CLI-35A

2-1839

Total Access/NetVanta Carrier CLI Dictionary

muxponder-ethernet <shelf/slot> qos cos-map <0-n> <0-7>


<0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7>
Syntax Description
<shelf/slot>

Specifiedslot

<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe6thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe7thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146745

2-1840

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

muxponder-ethernet <shelf/slot> qos untagged <0-7>


Syntax Description
<shelf/slot>

Specifiedslot

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146747

6TANV57CLI-35A

2-1841

Total Access/NetVanta Carrier CLI Dictionary

muxponder-ethernet <shelf/slot> queue time-constant wred


[125|16|2|250|32|4|500|62|8]
Syntax Description
<shelf/slot>

Specifiedslot

125

Approximately125msroundtripdelay

16

Approximately16msroundtripdelay

Approximately2msroundtripdelay

250

Approximately250msroundtripdelay

32

Approximately32msroundtripdelay

Approximately4msroundtripdelay

500

Approximately500msroundtripdelay

62

Approximately62msroundtripdelay

Approximately8msroundtripdelay

Functional Notes
Usethemuxponderethernet*queuestimeconstantwred?[2|4|8|16|32|62|125|250|500]
commandtoconfiguretheWREDtimeconstantforallqueues.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
146750

2-1842

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

network-name WORD
Usethiscommandtospecifythenetworknameforthisgroupofshelves.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46358

6TANV57CLI-35A

2-1843

Total Access/NetVanta Carrier CLI Dictionary

node-number <1-n>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46246

2-1844

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

policer WORD
UsethepolicerWORDcommandtoactivatethePolicerConfigurationCommandSet.Ifthe
policerdoesnotexist,anewoneiscreatedwithdefaultparameters.

Usage Examples
ThefollowingisanexampleofhowtousethepolicerWORDcommand.
(config)#policer myPolicer
(config-policer myPolicer)#

Functional Notes
UsetheWORDinputtodesignatethenameofthepolicerwhetheritbeforonealready
createdorforanewone.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
64492

6TANV57CLI-35A

2-1845

Total Access/NetVanta Carrier CLI Dictionary

policer WORD <shelf/slot>


UsethepolicerWORD<shelf/slot>commandtoactivatethePolicerConfigurationCommand
Setforthespecifiedshelfandslot.Ifthepolicerdoesnotexist,anewoneiscreatedwith
defaultparametersandthenamespecified.

Syntax Description
WORD

Nameofpolicer

Usage Examples
ThefollowingisanexampleofhowtousethepolicerWORD<shelf/slot>command.
(config)#policer myPolicer 1/0
(config-policer myPolicer 1/0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
89445

2-1846

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

power-shedding
UsethepowersheddingcommandtoactivatethePowerSheddingConfigurationCommand
Set.

Usage Examples
Thefollowingisanexampleofhowtousethepowersheddingcommand.
(config)#power-shedding
(config-pwr-shed)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77705

6TANV57CLI-35A

2-1847

Total Access/NetVanta Carrier CLI Dictionary

probe responder twamp


UsetheproberespondertwampcommandtoactivatetheTWAMPResponderConfiguration
CommandSetandconfiguretheunittorespondtoTWAMPactivemeasurementpackets.Use
thenoformofthiscommandtostoptheunitfromrespondingtoanyTWAMPactive
measurementpacketsandtodeleteallresponderperformancemonitoringhistoryandconfig
urationsettings.

Usage Examples
Thefollowingisanexampleofhowtousetheproberespondertwampcommand.
(config)#probe responder twamp
(config-twamp-responder)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45972

2-1848

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

protection-group [<shelf/group>|WORD]
Usetheprotectiongroup<shelf/group>commandsettoconfigureaprotectiongroup.A
protectiongrouphas1protectionmoduleandxnumberofaccessmodules.

Usage Examples
Thefollowingisanexampleofhowtousetheprotectiongroup[<shelf/group>|WORD]
command.
(config)#protection-group 1/1
(config-prot-group 1/1)#

Functional Notes
Ifthenamespecifieddoesnotexist,thenflagtheuserthatanewprotectiongrouphasbeen
created.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
58379

6TANV57CLI-35A

2-1849

Total Access/NetVanta Carrier CLI Dictionary

qos cos-map <0-n> <0-7>


Usetheqoscosmap<0n><07>commandtoenterthefirstLayer2CoSvalueassociatedwith
theselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07>command.
(config)#qos cos-map 7 0
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46295

2-1850

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7>


Usetheqoscosmap<0n><07><07>commandtoenterthesecondLayer2CoSvalue
associatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07>command.
(config)#qos cos-map 7 0 1
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59439

6TANV57CLI-35A

2-1851

Total Access/NetVanta Carrier CLI Dictionary

qos cos-map <0-n> <0-7> <0-7> <0-7>


Usetheqoscosmap<0n><07><07><07>commandtoenterthethirdLayer2CoSvalue
associatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07>command.
(config)#qos cos-map 7 0 1 2
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59472

2-1852

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7>


Usetheqoscosmap<0n><07><07><07><07>commandtoenterthefourthLayer2CoS
valueassociatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07><07>
command.
(config)#qos cos-map 7 0 1 2 3
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1853

Total Access/NetVanta Carrier CLI Dictionary

Command ID
59473

2-1854

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7>


Usetheqoscosmap<0n><07><07><07><07><07>commandtoenterthefifthLayer2
CoSvalueassociatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07><07><07>
command.
(config)#qos cos-map 7 0 1 2 3 4
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

6TANV57CLI-35A

2-1855

Total Access/NetVanta Carrier CLI Dictionary

Command ID
59474

2-1856

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7>


Usetheqoscosmap<0n><07><07><07><07><07><07>commandtoenterthesixth
Layer2CoSvalueassociatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07><07><07>
<07>command.
(config)#qos cos-map 7 0 1 2 3 4 5
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838

6TANV57CLI-35A

2-1857

Total Access/NetVanta Carrier CLI Dictionary

(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59475

2-1858

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <07>
Usetheqoscosmap<0n><07><07><07><07><07><07><07>commandtoenterthe
seventhLayer2CoSvalueassociatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe6thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07><07><07>
<07><07>command.
(config)#qos cos-map 7 0 1 2 3 4 5 6
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL

6TANV57CLI-35A

2-1859

Total Access/NetVanta Carrier CLI Dictionary

AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59476

2-1860

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos cos-map <0-n> <0-7> <0-7> <0-7> <0-7> <0-7> <0-7> <07> <0-7>
Usetheqoscosmap<0n><07><07><07><07><07><07><07><07>commandtoenter
theeighthLayer2CoSvalueassociatedwiththeselectedqueue.

Syntax Description
<0n>

Entertheclassqueuenumber,n=numberofqueues1

<07>

Enterthe1stassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe2ndassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe3rdassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe4thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe5thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe6thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

<07>

Enterthe7thassociatedLayer2ClassofService(Cos)valuewith
thisqueue

Usage Examples
Thefollowingisanexampleofhowtousetheqoscosmap<0n><07><07><07><07><07>
<07><07><07>command.
(config)#qos cos-map 7 0 1 2 3 4 5 6 7
(config)#

Functional Notes
Usethe<0n>inputtodesignatethequeue.Usethe<07>inputstoentertheLayer2CoS
valuesassociatedwiththeselectedqueue.ThevalidrangefortheCoSvalueis07.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-1861

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),SM(1187020E1),SM(1187020L1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59477

2-1862

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

qos untagged <0-7>


Usetheqosuntagged<07>commandtoentertheassociatedLayer2CoSusedforingress
untaggedtrafficwhentheMENpriorityissettoinherit.

Usage Examples
Thefollowingisanexampleofhowtousetheqosuntagged<07>command.
(config)#qos untagged 6
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65186

6TANV57CLI-35A

2-1863

Total Access/NetVanta Carrier CLI Dictionary

queue interface efm-group [<shelf/slot/group>|WORD] <0-n>


Usethequeueinterfaceefmgroup<shelf/slot/group><0n>commandtoactivatetheQueue
ConfigurationCommandSetfortheselectedinterfaceandqueuenumber.

Syntax Description
<shelf/slot/group>

Specifiedgroup

WORD

Specifiedinterfacebyalias

Usage Examples
Thefollowingisanexampleofhowtousethequeueinterfaceefmgroup[<shelf/slot/
group>|WORD]<0n>command.
(config)#queue interface efm-group 1 7
(config-queue 7 efm-group 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65778

2-1864

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

queue interface ethernet <shelf/slot/port> <0-n>


Usethequeueinterfaceethernet<shelf/slot/port><0n>commandtoactivatetheQueue
ConfigurationCommandSetfortheselectedinterfaceandqueuenumber.

Syntax Description
<shelf/slot/port>

EnterEthernetportnumber

Usage Examples
Thefollowingisanexampleofhowtousethequeueinterfaceethernet<shelf/slot/port><0n>
command.
(config)#queue interface ethernet 1/0/1 7
(config-queue 7 eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65776

6TANV57CLI-35A

2-1865

Total Access/NetVanta Carrier CLI Dictionary

queue interface gigabit-ethernet <shelf/slot/port> <0-n>


Usethequeueinterfacegigabitethernet<shelf/slot/port><0n>commandtoactivatethe
QueueConfigurationCommandSetfortheselectedinterfaceandqueuenumber.

Syntax Description
<shelf/slot/port>

EnterGigabitEthernetportnumber

Usage Examples
Thefollowingisanexampleofhowtousethequeueinterfacegigabitethernet<shelf/slot/
port><0n>command.
(config)#queue interface gigabit-ethernet 1/0/1 7
(config-queue 7 gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV
814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
65777

2-1866

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

queue interface muxponder-highspeed <shelf/slot/port> <0-n>


Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145688

6TANV57CLI-35A

2-1867

Total Access/NetVanta Carrier CLI Dictionary

queue interface muxponder-midspeed <shelf/slot/port> <0-n>


Usethequeueinterfacemuxpondermidspeed<shelf/slot/port><0n>commandtoactivate
theQueueConfigurationCommandSetfortheselectedinterfaceandqueuenumber.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Usage Examples
Thefollowingisanexampleofhowtousethequeueinterfacemuxpondermidspeed<shelf/
slot/port><0n>command.
(config)#queue interface muxponder-midspeed 1/0/1 7
(config-queue 7 muxponder-midspeed 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
145685

2-1868

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

queue interface ten-gigabit-ethernet <shelf/slot/port> <0-n>


Syntax Description
<shelf/slot/port>

EnterTenGigabitEthernetportnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67180

6TANV57CLI-35A

2-1869

Total Access/NetVanta Carrier CLI Dictionary

queue time-constant wred [125|16|2|250|32|4|500|62|8]


Usethequeuestimeconstantwred[2|4|8|16|32|62|125|250|500]commandtoconfigurethe
WREDtimeconstantforallqueues.

Syntax Description
125

Approximately125msroundtripdelay

16

Approximately16msroundtripdelay

Approximately2msroundtripdelay

250

Approximately250msroundtripdelay

32

Approximately32msroundtripdelay

Approximately4msroundtripdelay

500

Approximately500msroundtripdelay

62

Approximately62msroundtripdelay

Approximately8msroundtripdelay

Usage Examples
Thefollowingisanexampleofhowtousethequeuetimeconstantwred
[125|16|2|250|32|4|500|62|8]command.
(config)#queue time-constant wred 250
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65952

2-1870

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server auth-port <1024-65535>


Usetheradiusserverauthport<102465535>commandtospecifytheUDPportforRADIUS
authenticationqueries.ThisparametercanbeconfiguredseparatelyforeachRADIUSserver.
Incaseswhereitisnotprovisionedonaperserverbasis,thenetworkelementwilldeferto
thisglobaldefaultvalue.Usethenoformofthiscommandtorestorethisglobaldefaultvalue
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheradiusserverauthport<102465535>
command.
(config)#radius-server auth-port 1814
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23239

6TANV57CLI-35A

2-1871

Total Access/NetVanta Carrier CLI Dictionary

radius-server default-privilege
[admin|config|readonly|readwrite|test]
Usetheradiusserverdefaultprivilege[admin|config|readonly|readwrite|test]commandto
setthelocalprivilegelevelthatapplieswhenaRADIUSservergrantsauthenticationatlogin,
buttheserverresponsedoesnotcontaintheattributewiththelocalprivilegeleveltobe
assigned.Note:ForCLIsessions,thelocalreadwriteprivilegelevelisequivalenttothe
localtestprivilegelevel.

Syntax Description
admin

Adminprivileges

config

Configprivileges

readonly

Readonlyprivileges

readwrite

Readwriteprivileges

test

Testprivileges

Usage Examples
Thefollowingisanexampleofhowtousetheradiusserverdefaultprivilege
[admin|config|readonly|readwrite|test]command.
(config)#radius-server default-privilege readonly
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
59284

2-1872

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D auth-port <1024-65535> key


WORD
UsetheradiusserverhostA.B.C.Dauthport<102465535>keyWORDcommandtocreatethe
server(ifnotalreadycreated)andtosettheauthenticationportandkeyforthisserver.Use
thenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<102465535>

UDPporttousewhenconnectingtoradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dauthport<1024
65535>keyWORDcommand.
(config)#radius-server host 1.2.3.4 auth-port 1814 key adtran
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45365

6TANV57CLI-35A

2-1873

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D auth-port <1024-65535> key


WORD timeout <1-30>
UsetheradiusserverhostA.B.C.Dauthport<102465535>keyWORDtimeout<130>
commandtocreatetheserver(ifnotalreadycreated)andtosettheauthenticationport,key,
andtimeoutforthisserver.Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<102465535>

UDPporttousewhenconnectingtoradiusserver

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dauthport<1024
65535>keyWORDtimeout<130>command.
(config)#radius-server host 1.2.3.4 auth-port 1814 key adtran timeout 30
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45373

2-1874

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D auth-port <1024-65535> timeout


<1-30>
UsetheradiusserverhostA.B.C.Dauthport<102465535>timeout<130>commandtocreate
theserver(ifnotalreadycreated)andtosettheauthenticationportandtimeoutforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<102465535>

UDPporttousewhenconnectingtoradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dauthport<1024
65535>timeout<130>command.
(config)#radius-server host 1.2.3.4 auth-port 1814 timeout 30
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45369

6TANV57CLI-35A

2-1875

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D auth-port <1024-65535> timeout


<1-30> key WORD
UsetheradiusserverhostA.B.C.Dauthport<102465535>timeout<130>keyWORD
commandtocreatetheserver(ifnotalreadycreated)andtosettheauthenticationport,key,
andtimeoutforthisserver.Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<102465535>

UDPporttousewhenconnectingtoradiusserver

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dauthport<1024
65535>timeout<130>keyWORDcommand.
(config)#radius-server host 1.2.3.4 auth-port 1814 timeout 30 key adtran
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45377

2-1876

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D key WORD auth-port <102465535>


UsetheradiusserverhostA.B.C.DkeyWORDauthport<102465535>commandtocreatethe
server(ifnotalreadycreated)andtosetthekeyandauthenticationportforthisserver.Use
thenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.DkeyWORDauth
port<102465535>command.
(config)#radius-server host 1.2.3.4 key adtran auth-port 1814
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45337

6TANV57CLI-35A

2-1877

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D key WORD auth-port <102465535> timeout <1-30>


UsetheradiusserverhostA.B.C.DkeyWORDauthport<102465535>timeout<130>
commandtocreatetheserver(ifnotalreadycreated)andtosetthekey,authenticationport,
andtimeoutforthisserver.Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

WORD

Perserverencryptionkey(overridesdefault)

<102465535>

UDPporttousewhenconnectingtoradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.DkeyWORDauth
port<102465535>timeout<130>command.
(config)#radius-server host 1.2.3.4 key adtran auth-port 1814 timeout
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45345

2-1878

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D key WORD timeout <1-30>


Usetheradiusserverhost*key*timeoutcommandtocreatetheserver(ifnotalready
created)andtosetthekeyandtimeoutforthisserver.Usethenoformofthiscommandto
deletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.DkeyWORDtimeout
<130>command.
(config)#radius-server host 1.2.3.4 key adtran timeout 30
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45333

6TANV57CLI-35A

2-1879

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D key WORD timeout <1-30> authport <1024-65535>


Usetheradiusserverhost*key*timeout*authport*commandtocreatetheserver(ifnot
alreadycreated)andtosetthekey,timeout,andauthenticationportforthisserver.Usetheno
formofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

WORD

Perserverencryptionkey(overridesdefault)

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.DkeyWORDtimeout
<130>authport<102465535>command.
(config)#radius-server host 1.2.3.4 key adtran timeout 30 auth-port 1814
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45341

2-1880

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D name WORD


Usetheradiusserverhost*name*commandtocreatetheserver(ifnotalreadycreated)and
tosetthenameforthisserver.Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.DnameWORD
command.
(config)#radius-server host 1.2.3.4 name serverOne
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23226

6TANV57CLI-35A

2-1881

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D retransmit <1-255>


Usetheradiusserverhost*retransmit*commandtocreatetheserver(ifnotalreadycreated)
andtosetthenumberofretransmissionsforthisserver.Usethenoformofthiscommandto
deletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dretransmit<1255>
command.
(config)# radius-server host 1.2.3.4 retransmit 10
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23218

2-1882

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D sequence-number <0-4>


Usetheradiusserverhost*sequencenumber*commandtocreatetheserver(ifnotalready
created)andtosetthesequencenumberforthisserver.Usethenoformofthiscommandto
deletetheserver..TheserversequencenumbercontrolstheorderinwhichRADIUSservers
arequeried.Thesequencenumberneednotbeexplicitlyconfigured.Ifunspecified,the
sequencenumberfortheserverwillbesettoanonzerovalueintheorderinwhichthe
serversarecreated.Aserverhavingasequencenumberofzeroiseffectivelydisabled(never
queried).

Syntax Description
A.B.C.D

IPaddressofradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dsequencenumber
<04>command.
(config)#radius-server host 1.2.3.4 sequence-number 1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45317

6TANV57CLI-35A

2-1883

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D timeout <1-30> auth-port <102465535>


Usetheradiusserverhost*timeout*authportcommandtocreatetheserver(ifnotalready
created)andtosetthetimeoutandauthenticationportforthisserver.Usethenoformofthis
commandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dtimeout<130>
authport<102465535>command.
(config)#radius-server host 1.2.3.4 timeout 30 auth-port 1814
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45353

2-1884

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D timeout <1-30> auth-port <102465535> key WORD


Usetheradiusserverhost*timeout*authport*key*commandtocreatetheserver(ifnot
alreadycreated)andtosetthetimeout,authenticationport,andkeyforthisserver.Usetheno
formofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<130>

Timeoutvalueinsecondstowaitforservertoreply

<102465535>

UDPporttousewhenconnectingtoradiusserver

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dtimeout<130>
authport<102465535>keyWORDcommand.
(config)#radius-server host 1.2.3.4 timeout 30 auth-port 1814 key adtran
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45361

6TANV57CLI-35A

2-1885

Total Access/NetVanta Carrier CLI Dictionary

radius-server host A.B.C.D timeout <1-30> key WORD


Usetheradiusserverhost*timeout*keycommandtocreatetheserver(ifnotalready
created)andtosetthetimeoutandkeyforthisserver.Usethenoformofthiscommandto
deletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dtimeout<130>key
WORDcommand.
(config)#radius-server host 1.2.3.4 timeout 30 key adtran
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45349

2-1886

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server host A.B.C.D timeout <1-30> key WORD authport <1024-65535>


Usetheradiusserverhost*timeout*key*authportcommandtocreatetheserver(ifnot
alreadycreated)andtosetthetimeout,key,andauthenticationportforthisserver.Usetheno
formofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofradiusserver

<130>

Timeoutvalueinsecondstowaitforservertoreply

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverhostA.B.C.Dtimeout<130>key
WORDauthport<102465535>command.
(config)#radius-server host 1.2.3.4 timeout 30 key adtran auth-port 1814
(config)#

Functional Notes
TheRADIUSserverkey,authenticationport,timeout,andnumberofretransmissionscanbe
configuredonaperserverbasis.Iftheseparametersarenotconfiguredforagivenserver,the
networkelementwilldefertotheglobaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45357

6TANV57CLI-35A

2-1887

Total Access/NetVanta Carrier CLI Dictionary

radius-server key WORD


Usetheradiusserverkey*commandtospecifythesharedsecret(upto64ASCIIcharacters)
forRADIUSqueries.ThisparametercanbeconfiguredseparatelyforeachRADIUSserver.In
caseswhereitisnotprovisionedonaperserverbasis,thenetworkelementwilldefertothis
globaldefaultvalue.Usethenoformofthiscommandtorestorethisglobaldefaultvalueto
itsdefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousetheradiusserverkeyWORDcommand.
(config)#radius-server key adtran
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45305

2-1888

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server retransmit <1-255>


UsetheradiusserverretransmitcommandtospecifythenumberofUDPretransmissionsfor
RADIUSqueries.ThisparametercanbeconfiguredseparatelyforeachRADIUSserver.In
caseswhereitisnotprovisionedonaperserverbasis,thenetworkelementwilldefertothis
globaldefaultvalue.Usethenoformofthiscommandtorestorethisglobaldefaultvalueto
itsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheradiusserverretransmit<1255>command.
(config)#radius-server retransmit 10

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23233

6TANV57CLI-35A

2-1889

Total Access/NetVanta Carrier CLI Dictionary

radius-server timeout <1-30>


Usetheradiusservertimeout*commandtospecifythetimeout(inseconds)forRADIUS
queries.ThisparametercanbeconfiguredseparatelyforeachRADIUSserver.Incaseswhere
itisnotprovisionedonaperserverbasis,thenetworkelementwilldefertothisglobaldefault
value.Usethenoformofthiscommandtorestorethisglobaldefaultvaluetoitsdefault
setting.

Usage Examples
Thefollowingisanexampleofhowtousetheradiusservertimeout<130>command.
(config)#radius-server timeout 10
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45309

2-1890

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

radius-server tl1-login
Usetheradiusservertl1logintoenabletheuseofradiusauthenticationwithTL1.Usetheno
formtodisabletheuseofradiusauthenticationwithTL1.

Usage Examples
Thefollowingisanexampleofhowtousetheradiusservertl1logincommand.
(config)#radius-server tl1-login
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87727

6TANV57CLI-35A

2-1891

Total Access/NetVanta Carrier CLI Dictionary

redundancy <shelf/slot>
Functional Notes
Choosetheactivecardintheredundancypairtoconfigure.Thehelpwilldisplayalistof
activecardsinthesystem

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46242

2-1892

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

remote-device ont <remote-index>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133170

6TANV57CLI-35A

2-1893

Total Access/NetVanta Carrier CLI Dictionary

sca
UsethescacommandtoactivatetheSystemConfigurationArchiveConfigurationCommand
Set.

Usage Examples
Thefollowingisanexampleofhowtousethescacommand.
(config)#sca
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77704

2-1894

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

scr mode [auto|manual|scheduled]


Usethescrmode[auto|manual|scheduled]toconfigurethemodeofoperationforSystem
Controlledreboot.Usethenoformtosetthescrmodetothedefault.

Syntax Description
auto

Automaticallyrebootafteranupgrade

manual

Manualreboot

scheduled

Scheduledrebootatspecifieddateandtime

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83053

6TANV57CLI-35A

2-1895

Total Access/NetVanta Carrier CLI Dictionary

scr schedule <HH:MM> <1-31> MONTH <2000-2099>


Usethescrschedule<HH:MM><131>MONTH<20002099>tosetthedateandtimefor
whichaSystemControlledRebootwilloccur.Thescheduleddateandtimemustbewithin90
daysofthecurrentdateandtime.

Syntax Description
<HH:MM>

Timein24hourformat

<131>

Thedayofthemonth

MONTH

Monthoftheyear

Usage Examples
Thefollowingisanexampleofhowtousethescrschedule<HH:MM><131>MONTH<2000
2099>command.
(config)#scr schedule 12:00 31 January 2009
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83140

2-1896

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

security
UsethesecuritycommandtoactivatetheSecurityConfigurationCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethesecuritycommand.
(config)#security
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77807

6TANV57CLI-35A

2-1897

Total Access/NetVanta Carrier CLI Dictionary

shaper WORD [<shelf/slot>|<remote-index>]


UsetheshaperWORD<shelf/slot>commandtoactivatetheShaperConfigurationCommand
Setforthespecifiedshelfandslot.Iftheshaperdoesnotexist,anewoneiscreatedwith
defaultparametersandthenamespecified.

Syntax Description
WORD

Nameofshaper

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),QuadGPONAM(1187502F1),10GEthernetMuxponder(1174101F1),SM2GE
(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002
POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF
(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89443

2-1898

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

shdsl mode [ltu|ntu]


Usetheshdslmode[ltu|ntu]commandtoconfigureallSHDSLportsonthedevicetoeither
LTUorNTUmode.

Syntax Description
ltu

LineTerminationUnit

ntu

NetworkTerminationUnit

Usage Examples
Thefollowingisanexampleofhowtousetheshdslmode[ltu|ntu]command.
(config)#shdsl mode ltu
(config)#

Functional Notes
Thissettingrequiresareboot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV
838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1)

Command ID
42510

6TANV57CLI-35A

2-1899

Total Access/NetVanta Carrier CLI Dictionary

shdsl timeout training <60-240>


Usetheshdsltimeouttraining<60240>commandtoconfigurethetimeeachSHDSLport
waitsfortrainingtocompletebeforerestarting.

Usage Examples
Thefollowingisanexampleofhowtousetheshdsltimeouttraining<60240>command.
(config)#shdsl timeout training 120
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV
838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA
838(1200633G7)

Command ID
42515

2-1900

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

slot alarm enable shutdown maintenance <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),GPONAM
(1187501G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM
(1187551E1),ActiveEth24PortAM(1187560F1),QuadGPONAM(1187502F1),DS1Frame
Relay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
110647

6TANV57CLI-35A

2-1901

Total Access/NetVanta Carrier CLI Dictionary

slot shutdown <shelf/slot>


Usetheslotshutdown<shelf/slot>commandtoadministrativelydisablethecardlocatedin
thespecifiedslot.Usethenoslotshutdown<shelf/slot>commandtoenablethecard.If
supported,usetheslotshutdownmaintenance<shelf/slot>commandtoenablethecardbut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheslotshutdown<shelf/slot>command.
! To disable the card:
(config)#slot shutdown 1/9
(config)#
! To enable the card:
(config)#no slot shutdown 1/9
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
67273

2-1902

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

slot shutdown maintenance <shelf/slot>


Usetheslotshutdownmaintenance<shelf/slot>commandtoenabletheslotandallowitto
passdatabutinhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheslotshutdownmaintenance<shelf/slot>
command.
(config)#slot shutdown maintenance 1/9
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94356

6TANV57CLI-35A

2-1903

Total Access/NetVanta Carrier CLI Dictionary

slot shutdown unassigned <shelf/slot>


Usetheslotshutdownunassigned<shelf/slot>commandtoadministrativelydisablethecard
locatedinthespecifiedslot.Usethenoslotshutdown<shelf/slot>commandtoenablethe
card.Ifsupported,usetheslotshutdownmaintenance<shelf/slot>commandtoenablethe
cardbutinhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheslotshutdownunassigned<shelf/slot>
command.
(config)#slot shutdown unassigned 1/1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS3CCAM(1187260G1),EFMDS3CHAM
(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTL
AM(1188180E1),EFME1AM(1188802G1),FIBERAM(1187552G1),DS1PPPAM
(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),ADSL2AM
(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),RPOTSAM(1187150L1),GPONAM(1187501G1),QuadGigELM(1187550E1),
QuadGigELM(1187550G2),QuadGigELM(1187551E1),VDSL2Combo24PAM
(1187120L1),VDSL2AM(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),E1
CEM32PortAM(1188801G1),ActiveEth24PortAM(1187560F1),QuadGPONAM
(1187502F1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM
(1187220G3),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM(1187020L1),SM
2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
94358

2-1904

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

slot-alarm <shelf/slot>
Functional Notes
Usetheinterfaceslotalarm<shelf/slot>commandtoactivatethe?SlotAlarm?Configuration
CommandSetforthespecifiedslot.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
130330

6TANV57CLI-35A

2-1905

Total Access/NetVanta Carrier CLI Dictionary

snmp-server [chassis-id-tid-sync|config-change|non-vol-cardstatus]
CommandsforconfiguringtheSNMPserver

Syntax Description
chassisidtidsync

AutomaticallysynchronizethechassisIDwiththeTID

configchange

Setconfigurationchangetrapparameters

nonvolcardstatus

Enablenonvolstorageofthemodulestatus

Functional Notes
CommandsforconfiguringtheSNMPserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
44089

2-1906

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server alarm enable authenticate-failure


Usethesnmpserveralarmenableauthenticatefailuretoenableanalarmtobedeclarewhen
anauthenticationfailurehasoccurred.Usethenoformtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethesnmpserveralarmenableauthenticatefailure
command.
(config)#snmp-server alarm enable authenticate-failure
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86815

6TANV57CLI-35A

2-1907

Total Access/NetVanta Carrier CLI Dictionary

snmp-server chassis-id WORD


UsethesnmpserverchassisidWORDcommandtospecifyanidentifierfortheSNMPserver.
Usethenoformofthiscommandtoreturntothedefaultvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverchassisidWORDcommand.
(config)#snmp-server chassis-id A432692
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44871

2-1908

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server community read-only WORD


UsethesnmpservercommunityreadonlyWORDcommandtospecifythecommunityhas
readonlyaccessrights.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpservercommunityreadonlyWORD
command.
(config)#snmp-server community read-write public
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44883

6TANV57CLI-35A

2-1909

Total Access/NetVanta Carrier CLI Dictionary

snmp-server community read-write WORD


UsethesnmpservercommunityreadwriteWORDcommandtospecifythecommunityhas
readonlyaccessrights.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpservercommunityreadwriteWORD
command.
(config)#snmp-server community read-write private
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44886

2-1910

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server config-change ignore source A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
123832

6TANV57CLI-35A

2-1911

Total Access/NetVanta Carrier CLI Dictionary

snmp-server config-change ignore type controller


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
123834

2-1912

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server contact WORD


UsethesnmpservercontactWORDcommandtospecifySNMPservercontactinformation.
Usethenoformofthiscommandtoremoveaconfiguredcontact.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpservercontactWORDcommand.
(config)#snmp-server contact 6536999
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44880

6TANV57CLI-35A

2-1913

Total Access/NetVanta Carrier CLI Dictionary

snmp-server enable traps


UsethesnmpserverenabletrapscommandtoenableallSNMPtrapsavailableonthesystem.
UsethenoformofthiscommandtodisableSNMPtraps.

Usage Examples
Thefollowingisanexampleofhowtousethesnmpserverenabletrapscommand.
(config)#snmp-server enable traps snmp
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44868

2-1914

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server ez-provisioning host A.B.C.D traps version [1|2c]


Syntax Description
A.B.C.D

IPaddress

Trapversion1

2c

Trapversion2

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
139876

6TANV57CLI-35A

2-1915

Total Access/NetVanta Carrier CLI Dictionary

snmp-server host A.B.C.D


UsethesnmpserverhostA.B.C.Dcommandtospecifyatraphost.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverhostA.B.C.Dcommand.
(config)#snmp-server host 192.168.1.1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43947

2-1916

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server host A.B.C.D traps [config-change|confirmation]


Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

configchange

Configurationchangetraps

confirmation

Enabletrapconfirmationforthishost

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
43948

6TANV57CLI-35A

2-1917

Total Access/NetVanta Carrier CLI Dictionary

snmp-server host A.B.C.D traps config-change enable


Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
123835

2-1918

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server host A.B.C.D traps mode [invalid|undercreation|valid]


UsesnmpserverhostA.B.C.Dmode[createrequest|invalid|undercreation|valid]tosetthe
stateoftheSNMPtraphost.Thiscanensurethatnoerroneoustrapsaresentduringthe
configurationofthetraphost.

Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

invalid

SNMPhostmodetoinvalid

undercreation

SNMPhostmodetoundercreation

valid

SNMPhostmodetovalid

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87600

6TANV57CLI-35A

2-1919

Total Access/NetVanta Carrier CLI Dictionary

snmp-server host A.B.C.D traps retry-limit <0-10>


UsethesnmpserverhostA.B.C.Dtrapsretrylimit<110>tosetthemaximumnumberoftrap
retriesfortheprovisionedhost.

Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverhostA.B.C.Dtrapsretrylimit<0
10>command.
(config)#snmp-server host 192.168.1.1 traps retry limit 10
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
43956

2-1920

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server host A.B.C.D traps timeout <1-10>


UsethesnmpserverhostA.B.C.Dtrapstimeout<110>tosetthemaximumtraptimeout.

Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverhostA.B.C.Dtrapstimeout<110>
command.
(config)#snmp-server host 192.168.1.1 traps timeout 10
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
43958

6TANV57CLI-35A

2-1921

Total Access/NetVanta Carrier CLI Dictionary

snmp-server host A.B.C.D traps version [1|2c]


UsethesnmpserverhostA.B.C.Dtrapsversion[1|2c]commandtosettheSNMPversion
usedforsendingtraps.

Syntax Description
A.B.C.D

DestinationIPaddressforSNMPtraps

SNMPv1

2c

SNMPv2c

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverhostA.B.C.Dtrapsversion[1|2c]
command.
(config)#snmp-server host 192.168.1.1 traps version 2c
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
43959

2-1922

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

snmp-server ifindex-mode [fixed|sequential]


Syntax Description
fixed

Fixedindexingbasedoninterfacetype

sequential

Sequentialindexingofallinterfaces

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
105106

6TANV57CLI-35A

2-1923

Total Access/NetVanta Carrier CLI Dictionary

snmp-server location WORD


UsethesnmpserverlocationWORDcommandtospecifytheSimpleNetworkManagement
Protocol(SNMP)systemlocationstring.Usethenoformofthiscommandtoreturntothe
defaultvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesnmpserverlocationWORDcommand.
(config)#snmp-server location ?5th Floor Network Room?
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44876

2-1924

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

srm
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86936

6TANV57CLI-35A

2-1925

Total Access/NetVanta Carrier CLI Dictionary

system-alarm
UsethesystemalarmcommandtoactivatetheSystemAlarmCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethesystemalarmcommand.
(config)#system-alarm
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
61368

2-1926

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

system-alarm <shelf>
Usethesystemalarm<shelf>commandtoactivatetheSystemAlarmCommandSetforthe
specifiedshelf.

Usage Examples
Thefollowingisanexampleofhowtousethesystemalarm<shelf>command.
(config)#system-alarm 1
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
61369

6TANV57CLI-35A

2-1927

Total Access/NetVanta Carrier CLI Dictionary

system-management-evc
UsethesystemmanagementevccommandtoactivatetheSystemManagementEVC
CommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethesystemmanagementevccommand.
(config)#system-management-evc
(config-sys-mgmt-evc)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),SCM(1188010E1),SCM(1187010L1),SCMG2
(1187010G2),SCMwithBridging(1187011G1),NV814(1200637G4),NV818(1200637G2),NV
824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
65585

2-1928

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

system-timing <shelf>
Usethesystemtiming<shelf>commandtoactivatetheSystemTimingCommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethesystemtiming<shelf>command.
(config)#system-timing 1
(config-sys-timing shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1)

Command ID
46125

6TANV57CLI-35A

2-1929

Total Access/NetVanta Carrier CLI Dictionary

t1e1 mode [e1|t1]


Usethet1e1modecommandtoconfigureT1orE1mode.

Syntax Description
e1

SelectE1mode

t1

SelectT1mode

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1INTLPPPAM(1188803G2),NV814(1200637G4),NV818(1200637G2)

Command ID
45661

2-1930

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D key WORD port <1-65535>


UsethetacacsserverhostA.B.C.DkeyWORDport<165535>commandtocreatetheserver
(ifnotalreadycreated)andtosetthekeyandportforthisserver.Usethenoformofthis
commandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.DkeyWORDport<1
65535>command.
(config)#tacacs-server host 1.2.3.4 key adtran port 49
(config)#

Functional Notes
Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45414

6TANV57CLI-35A

2-1931

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D key WORD port <1-65535>


timeout <1-30>
UsethetacacsserverhostA.B.C.DkeyWORDport<165535>timeout<130>commandto
createtheserver(ifnotalreadycreated)andtosetthekey,port,andtimeoutforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

WORD

Perserverencryptionkey(overridesdefault)

<165535>

TCPporttousewhenconnectingtoTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.DkeyWORDport<1
65535>timeout<130>command.
(config)#tacacs-server host 1.2.3.4 key adtran port 49 timeout 30
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45422

2-1932

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D key WORD timeout <1-30>


UsethetacacsserverhostA.B.C.DkeyWORDtimeout<130>commandtocreatetheserver
(ifnotalreadycreated)andtosetthekeyandtimeoutforthisserver.Usethenoformofthis
commandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.DkeyWORDtimeout
<130>command.
(config)#tacacs-server host 1.2.3.4 key adtran timeout 30
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45410

6TANV57CLI-35A

2-1933

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D key WORD timeout <1-30> port


<1-65535>
UsethetacacsserverhostA.B.C.DkeyWORDtimeout<130>port<165535>commandto
createtheserver(ifnotalreadycreated)andtosetthekey,timeout,andportforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

WORD

Perserverencryptionkey(overridesdefault)

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.DkeyWORDtimeout
<130>port<165535>command.
(config)#tacacs-server host 1.2.3.4 key adtran timeout 30 port 49
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45418

2-1934

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D name WORD


UsethetacacsserverhostA.B.C.DnameWORDcommandtospecifythenameforaremote
TACACS+server.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.DnameWORD
command.
(config)#tacacs-server host 1.2.3.4 name serverOne
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23253

6TANV57CLI-35A

2-1935

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D port <1-65535> key WORD


UsethetacacsserverhostA.B.C.Dport<165535>keyWORDcommandtocreatetheserver
(ifnotalreadycreated)andtosettheportandkeyforthisserver.Usethenoformofthis
commandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<165535>

TCPporttousewhenconnectingtoTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dport<165535>key
WORDcommand.
(config)#tacacs-server host 1.2.3.4 port 49 key adtran
(config)#

Functional Notes
Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45442

2-1936

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D port <1-65535> key WORD


timeout <1-30>
UsethetacacsserverhostA.B.C.Dport<165535>keyWORDtimeout<130>commandto
createtheserver(ifnotalreadycreated)andtosettheport,key,andtimeoutforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<165535>

TCPporttousewhenconnectingtoTACACS+server

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dport<165535>key
WORDtimeout<130>command.
(config)#tacacs-server host 1.2.3.4 port 49 key adtran timeout 30
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45450

6TANV57CLI-35A

2-1937

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D port <1-65535> timeout <1-30>


UsethetacacsserverhostA.B.C.Dport<165535>timeout<130>commandtocreatethe
server(ifnotalreadycreated)andtosettheportandtimeoutforthisserver.Usethenoform
ofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<165535>

TCPporttousewhenconnectingtoTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dport<165535>
timeout<130>command.
(config)#tacacs-server host 1.2.3.4 port 49 timeout 30
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45446

2-1938

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D port <1-65535> timeout <1-30>


key WORD
UsethetacacsserverhostA.B.C.Dport<165535>timeout<130>keyWORDcommandto
createtheserver(ifnotalreadycreated)andtosettheport,timeout,andkeyforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<165535>

TCPporttousewhenconnectingtoTACACS+server

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dport<165535>
timeout<130>keyWORDcommand.
(config)#tacacs-server host 1.2.3.4 port 49 timeout 30 key adtran
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45454

6TANV57CLI-35A

2-1939

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D sequence-number <0-4>


Usethetacacsserverhost*sequencenumber*commandtocreatetheserver(ifnotalready
created)andtosetthesequencenumberforthisserver.Usethenoformofthiscommandto
deletetheserver..TheserversequencenumbercontrolstheorderinwhichTACACS+servers
arequeried.Thesequencenumberneednotbeexplicitlyconfigured.Ifunspecified,the
sequencenumberfortheserverwillbesettoanonzerovalueintheorderinwhichthe
serversarecreated.Aserverhavingasequencenumberofzeroiseffectivelydisabled(never
queried).

Syntax Description
A.B.C.D

IPaddressofTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dsequencenumber
<04>command.
(config)#tacacs-server host 1.2.3.4 sequence-number 1
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45394

2-1940

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D timeout <1-30> key WORD


UsethetacacsserverhostA.B.C.Dtimeout<130>keyWORDcommandtocreatetheserver
(ifnotalreadycreated)andtosetthetimeoutandkeyforthisserver.Usethenoformofthis
commandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dtimeout<130>key
WORDcommand.
(config)#tacacs-server host 1.2.3.4 timeout 30 key adtran
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45426

6TANV57CLI-35A

2-1941

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D timeout <1-30> key WORD port


<1-65535>
UsethetacacsserverhostA.B.C.Dtimeout<130>keyWORDport<165535>commandto
createtheserver(ifnotalreadycreated)andtosetthetimeout,key,andportforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<130>

Timeoutvalueinsecondstowaitforservertoreply

WORD

Perserverencryptionkey(overridesdefault)

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dtimeout<130>key
WORDport<165535>command.
(config)#tacacs-server host 1.2.3.4 timeout 30 key adtran port 49
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45434

2-1942

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server host A.B.C.D timeout <1-30> port <1-65535>


UsethetacacsserverhostA.B.C.Dtimeout<130>port<165535>commandtocreatethe
server(ifnotalreadycreated)andtosetthetimeoutandportforthisserver.Usethenoform
ofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<130>

Timeoutvalueinsecondstowaitforservertoreply

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dtimeout<130>port
<165535>command.
(config)#tacacs-server host 1.2.3.4 timeout 30 port 49
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45430

6TANV57CLI-35A

2-1943

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server host A.B.C.D timeout <1-30> port <1-65535>


key WORD
UsethetacacsserverhostA.B.C.Dtimeout<130>port<165535>keyWORDcommandto
createtheserver(ifnotalreadycreated)andtosetthetimeout,port,andkeyforthisserver.
Usethenoformofthiscommandtodeletetheserver.

Syntax Description
A.B.C.D

IPaddressofTACACS+server

<130>

Timeoutvalueinsecondstowaitforservertoreply

<165535>

TCPporttousewhenconnectingtoTACACS+server

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverhostA.B.C.Dtimeout<130>port
<165535>keyWORDcommand.
(config)#tacacs-server host 1.2.3.4 timeout 30 port 49 key adtran
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.Thevalidrangefortheportis165535.
TheTACACS+serverkey,TCPport,andtimeoutcanbeconfiguredonaperserverbasis.If
theseparametersarenotconfiguredforagivenserver,thenetworkelementwilldefertothe
globaldefaultvaluewhenqueryingthatserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45438

2-1944

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server key WORD


Usethetacacsserverkey*commandtospecifythesharedsecret(upto64ASCIIcharacters)
forTACACS+queries.ThisparametercanbeconfiguredseparatelyforeachTACACS+server.
Incaseswhereitisnotprovisionedonaperserverbasis,thenetworkelementwilldeferto
thisglobaldefaultvalue.Usethenoformofthiscommandtorestorethisglobaldefaultvalue
toitsdefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousethetacacsserverkeyWORDcommand.
(config)#tacas-server key adtran
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45382

6TANV57CLI-35A

2-1945

Total Access/NetVanta Carrier CLI Dictionary

tacacs-server port <1-65535>


Usethetacacsserverport<165535>commandtospecifytheTCPportforTACACS+queries.
ThisparametercanbeconfiguredseparatelyforeachTACACS+server.Incaseswhereitis
notprovisionedonaperserverbasis,thenetworkelementwilldefertothisglobaldefault
value.Usethenoformofthiscommandtorestorethisglobaldefaultvaluetoitsdefault
setting.

Usage Examples
Thefollowingisanexampleofhowtousethetacacsserverport<165535>command.
(config)#tacacs-server port 49
(config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
23216

2-1946

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tacacs-server timeout <1-30>


Usethetacacsservertimeout*commandtospecifythetimeout(inseconds)forTACACS+
queries.ThisparametercanbeconfiguredseparatelyforeachTACACS+server.Incases
whereitisnotprovisionedonaperserverbasis,thenetworkelementwilldefertothisglobal
defaultvalue.Usethenoformofthiscommandtorestorethisglobaldefaultvaluetoits
defaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethetacacsservertimeout<130>command.
(config)#tacacs-server timeout 10
(config)#

Functional Notes
Thevalidrangeforthetimeoutis130seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45386

6TANV57CLI-35A

2-1947

Total Access/NetVanta Carrier CLI Dictionary

temperature-sensor <shelf/slot/sensor>
Usethetemperaturesensor<shelf/slot/sensor>commandtoactivatetheTemperatureSensor
ConfigurationCommandSet.Usethiscommandsettoconfiguretemperaturethresholdsin
CelsiusorFahrenheit.Usethenoformofthiscommandtosetthetemperaturethresholdsto
thedefaultsof65degreesforCelsiusand149degreesforFahrenheit.

Usage Examples
Thefollowingisanexampleofhowtousethetemperaturesensor<shelf/slot/sensor>
command.
(config)#temperature-sensor 1/0/1
(config-temp-sensor 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA500023inchFan(1187080L1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77232

2-1948

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

tl1
Usethetl1commandtoactivatetheTL1CommandSet.

Usage Examples
Thefollowingisanexampleofhowtousethetl1command.
(config)#tl1
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77707

6TANV57CLI-35A

2-1949

Total Access/NetVanta Carrier CLI Dictionary

voice class-of-service WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95802

2-1950

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice conference local originator flashhook [drop|ignore|split]


Syntax Description
drop

Dropthelastpartyadded

ignore

Ignoreflashhook

split

Splittheconference

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
127952

6TANV57CLI-35A

2-1951

Total Access/NetVanta Carrier CLI Dictionary

voice conference mode [local|network]


Syntax Description
local

Conferenceshandledinternally

network

Conferenceshandledbyremoteconferenceserver

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
127962

2-1952

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan 900-number <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95824

6TANV57CLI-35A

2-1953

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan always-permitted <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95808

2-1954

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan internal <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95810

6TANV57CLI-35A

2-1955

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan international <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95816

2-1956

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan local <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95812

6TANV57CLI-35A

2-1957

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan national <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95814

2-1958

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan operator-assisted <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95820

6TANV57CLI-35A

2-1959

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan specify-carrier <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95818

2-1960

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan toll-free <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95822

6TANV57CLI-35A

2-1961

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan user1 <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95826

2-1962

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice dial-plan user2 <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95828

6TANV57CLI-35A

2-1963

Total Access/NetVanta Carrier CLI Dictionary

voice dial-plan user3 <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95830

2-1964

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice flashhook mode [interpreted|transparent]


Syntax Description
interpreted

Internallyinterpretflashhookevents

transparent

Providertransparentlyhandlesflashhookevents

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
127966

6TANV57CLI-35A

2-1965

Total Access/NetVanta Carrier CLI Dictionary

voice sip-trunk <Txx>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111566

2-1966

6TANV57CLI-35A

Section 2, Commands - Global Configuration Command Set

voice spre <PATTERN>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111784

6TANV57CLI-35A

2-1967

Total Access/NetVanta Carrier CLI Dictionary

voice user NUMBER:20


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111570

2-1968

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

GPON Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface gpon <shelf/slot/port>
ChassisId(config-gpon x/x/x)#

ThefollowingisalistofcommandsavailableintheGPONInterfaceConfigurationCommand
Set.
activationmode[autoactivate|autodiscover|manual|registration]
exit
fec
range[extended|maximum|standard]
shutdown[maintenance|unassigned]
subtendedhost<164>ipaddressA.B.C.DA.B.C.D
subtendedhost<164>ipaddressdhcp
subtendedhost<164>ipdefaultgatewayA.B.C.D
subtendedhost<164>stag<14094>
subtendedhost<164>stagpriority<07>

6TANV57CLI-35A

2-1969

Total Access/NetVanta Carrier CLI Dictionary

activation-mode [auto-activate|autodiscover|manual|registration]
UseactivationmodetosettheONTactivatingprocess.Thatincludesmanual,autodiscover,
autoactivate,registration.

Syntax Description
autoactivate

PeriodicallysearchfornewONTsandautomaticallyactivate
newlydiscoveredONTswiththenextavailableONUID

autodiscover

PeriodicallysearchfornewONTsanddisableautomatical
activatingfeature

manual

OnlyrequiresaprovisionedSNinordertoactivateanONT

registration

PeriodicallysearchfornewONTs,learnaSNifaregistrationID
isprovisionedforaspecificONT,andactivatetheONTifreg

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
144364

2-1970

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

exit
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136561

6TANV57CLI-35A

2-1971

Total Access/NetVanta Carrier CLI Dictionary

fec
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136552

2-1972

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

range [extended|maximum|standard]
Usetherangestandard,rangeextended,rangemaximumtochoosearangeindicationforthe
aPON.Userangeornorange*$tosetthevaluetothedefaultone(standard).

Syntax Description
extended

Extendedrange37.5KM

maximum

Maximumrange60KM

standard

Standardrange20KM

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139090

6TANV57CLI-35A

2-1973

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
136546

2-1974

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

subtended-host <1-64> ip address A.B.C.D A.B.C.D


UsethesubtendedhostcommandtofinishtheconfigurationsuchasONTmanagement
provisioning.

Syntax Description
<164>

ONTID

A.B.C.D

IPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139105

6TANV57CLI-35A

2-1975

Total Access/NetVanta Carrier CLI Dictionary

subtended-host <1-64> ip address dhcp


UsethesubtendedhostcommandtofinishtheconfigurationsuchasONTmanagement
provisioning.

Syntax Description
<164>

ONTID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139545

2-1976

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

subtended-host <1-64> ip default-gateway A.B.C.D


UsethesubtendedhostcommandtofinishtheconfigurationsuchasONTmanagement
provisioning.

Syntax Description
<164>

ONTID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139107

6TANV57CLI-35A

2-1977

Total Access/NetVanta Carrier CLI Dictionary

subtended-host <1-64> s-tag <1-4094>


UsethesubtendedhostcommandtofinishtheconfigurationsuchasONTmanagement
provisioning.

Syntax Description
<164>

ONTID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139099

2-1978

6TANV57CLI-35A

Section 2, Commands - GPON Interface Configuration Command Set

subtended-host <1-64> s-tag-priority <0-7>


UsethesubtendedhostcommandtofinishtheconfigurationsuchasONTmanagement
provisioning.

Syntax Description
<164>

ONTID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
GPONAM(1187501G1),QuadGPONAM(1187502F1)

Command ID
139101

6TANV57CLI-35A

2-1979

Total Access/NetVanta Carrier CLI Dictionary

HDSL2 Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface hdsl2 <shelf/slot/port>
ChassisId(config-hdsl2 x/x/x)#

ThefollowingisalistofcommandsavailableintheHDSL2InterfaceConfiguration
CommandSet.
descriptionLINE
exit
loopbacklocalline
remoteloopbackniu
shutdown
thresholdses15minute<0900>
thresholdses24hour<086400>
thresholdsloopattenuation<0127>
thresholdsses15minute<0900>
thresholdsses24hour<086400>
thresholdssnrmargin<015>
thresholdsuas15minute<0900>
thresholdsuas24hour<086400>
timeoutloopback[2hour|none]

2-1980

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedHDSL2interface.Usethenoform
ofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-hdsl2 1/0/1)#description HDSL2 Port 1
(config-hdsl2 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78942

6TANV57CLI-35A

2-1981

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43771

2-1982

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

loopback local line


UsetheloopbacklocalcommandtoinitiatealoopbackonthelocalHDSL2interface.Usethe
noformofthiscommandtoterminatetheloopback.

Usage Examples
Thefollowingisanexampleofhowtousetheloopbacklocallinecommand.
(config-hdsl2 1/0/1)#loopback local line
(config-hdsl2 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
43824

6TANV57CLI-35A

2-1983

Total Access/NetVanta Carrier CLI Dictionary

remote-loopback niu
UsetheremoteloopbackcommandtoconfiguretheHDSL2interfacetorespondtoaremotely
initiatedloopback.Usethenoformofthiscommandtodisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheremoteloopbackniucommand.
(config-hdsl2 1/0/1)#remote-loopback niu

Functional Notes
Bydefault,theNIUloopbackoptionisenabled.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78845

2-1984

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-hdsl2 1/0/1)#shutdown
(config-hdsl2 1/0/1)#
! To enable the interface:
(config-hdsl2 1/0/1)#no shutdown
(config-hdsl2 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78953

6TANV57CLI-35A

2-1985

Total Access/NetVanta Carrier CLI Dictionary

thresholds es 15-minute <0-900>


Usethethresholdses15minutecommandtoconfigure15minuteErroredSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses15minute<0900>command.
(config-hdsl2 1/0/1)#thresholds es 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78854

2-1986

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

thresholds es 24-hour <0-86400>


Usethresholdses24hourcommandtoconfigure24hourErroredSecondsperformance
monitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses24hour<086400>command.
(config-hdsl2 1/0/1)#thresholds es 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78856

6TANV57CLI-35A

2-1987

Total Access/NetVanta Carrier CLI Dictionary

thresholds loop-attenuation <0-127>


Usethethresholdsloopattenuationcommandtoconfiguretheloopattenuationthresholds.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsloopattenuation<0127>command.
(config-hdsl2 1/0/1)#thresholds loop-attenuation 35

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78851

2-1988

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

thresholds ses 15-minute <0-900>


Usethresholdsses15minutecommandtoconfigure15minuteSeverelyErroredSeconds
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses15minute<0900>command.
(config-hdsl2 1/0/1)#thresholds ses 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78859

6TANV57CLI-35A

2-1989

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses 24-hour <0-86400>


Usethresholdsses24hourcommandtoconfigure24hourSeverelyErroredSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses24hour<086400>command.
(config-hdsl2 1/0/1)#thresholds ses 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78861

2-1990

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

thresholds snr-margin <0-15>


UsethethresholdssnrmargincommandtoconfiguretheSNRmarginthresholds

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssnrmargin<015>command.
(config-hdsl2 1/0/1)#thresholds snr-margin 10

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78849

6TANV57CLI-35A

2-1991

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas 15-minute <0-900>


Usethresholdsuas15minutecommandtoconfigure15minuteUnavailableSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas15minute<0900>command.
(config-hdsl2 1/0/1)#thresholds uas 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78866

2-1992

6TANV57CLI-35A

Section 2, Commands - HDSL2 Interface Configuration Command Set

thresholds uas 24-hour <0-86400>


Usethresholdsuas24hourcommandtoconfigure24hourUnavailableSecondsperformance
monitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas24hour<086400>command.
(config-hdsl2 1/0/1)#thresholds uas 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78864

6TANV57CLI-35A

2-1993

Total Access/NetVanta Carrier CLI Dictionary

timeout loopback [2-hour|none]


Usethetimeoutcommandtoconfigureatimeoutusedtoautomaticallyremoveanyactive
loopbackortestpatternontheHDSL2interface.Usethenoformofthiscommandtoreturn
thetimeouttoitsdefaultsetting.

Syntax Description
2hour

2HourTimeout

none

NoTimeout

Usage Examples
Thefollowingisanexampleofhowtousethetimeoutloopback[2hour|none]command.
(config-hdsl2 1/0/1)#timeout loopback 2-hour
(config-hdsl2 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV824(1200634G4),NV828(1200634G2)

Command ID
78947

2-1994

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

HDSL4 Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface hdsl4 <shelf/slot/port>
ChassisId(config-hdsl4 x/x/x)#

ThefollowingisalistofcommandsavailableintheHDSL4InterfaceConfiguration
CommandSet.
descriptionLINE
exit
loopbacklocalline
remoteloopbackniu
shutdown
thresholdses15minute<0900>
thresholdses24hour<086400>
thresholdsloopattenuation<0127>
thresholdsses15minute<0900>
thresholdsses24hour<086400>
thresholdssnrmargin<015>
thresholdsuas15minute<0900>
thresholdsuas24hour<086400>
timeoutloopback[2hour|none]

6TANV57CLI-35A

2-1995

Total Access/NetVanta Carrier CLI Dictionary

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedHDSL4interface.Usethenoform
ofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-hdsl4 1/0/1)#description HDSL4 Port 1
(config-hdsl4 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78944

2-1996

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
NV844(1200635G2)

Command ID
43840

6TANV57CLI-35A

2-1997

Total Access/NetVanta Carrier CLI Dictionary

loopback local line


UsetheloopbacklocalcommandtoinitiatealoopbackonthelocalHDSL4interface.Usethe
noformofthiscommandtoterminatetheloopback.

Usage Examples
Thefollowingisanexampleofhowtousetheloopbacklocallinecommand.
(config-hdsl4 1/0/1)#loopback local line
(config-hdsl4 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
43893

2-1998

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

remote-loopback niu
UsetheremoteloopbackcommandtoconfiguretheHDSL4interfacetorespondtoaremotely
initiatedloopback.Usethenoformofthiscommandtodisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheremoteloopbackniucommand.
(config-hdsl4 1/0/1)#remote-loopback niu

Functional Notes
Bydefault,theNIUloopbackoptionisenabled.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78920

6TANV57CLI-35A

2-1999

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To diable the interface:
(config-hdsl4 1/0/1)#shutdown
(config-hdsl4 1/0/1)#
! To enable the interface:
(config-hdsl4 1/0/1)#no shutdown
(config-hdsl4 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78954

2-2000

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

thresholds es 15-minute <0-900>


Usethethresholdses15minutecommandtoconfigure15minuteErroredSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses15minute<0900>command.
(config-hdsl4 1/0/1)#thresholds es 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78928

6TANV57CLI-35A

2-2001

Total Access/NetVanta Carrier CLI Dictionary

thresholds es 24-hour <0-86400>


Usethresholdses24hourcommandtoconfigure24hourErroredSecondsperformance
monitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses24hour<086400>command.
(config-hdsl4 1/0/1)#thresholds es 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78930

2-2002

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

thresholds loop-attenuation <0-127>


Usethethresholdsloopattenuationcommandtoconfiguretheloopattenuationthresholds.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsloopattenuation<0127>command.
(config-hdsl4 1/0/1)#thresholds loop-attenuation 35

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78925

6TANV57CLI-35A

2-2003

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses 15-minute <0-900>


Usethresholdsses15minutecommandtoconfigure15minuteSeverelyErroredSeconds
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses15minute<0900>command.
(config-hdsl4 1/0/1)#thresholds ses 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78933

2-2004

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

thresholds ses 24-hour <0-86400>


Usethresholdsses24hourcommandtoconfigure24hourSeverelyErroredSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses24hour<086400>command.
(config-hdsl4 1/0/1)#thresholds ses 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78935

6TANV57CLI-35A

2-2005

Total Access/NetVanta Carrier CLI Dictionary

thresholds snr-margin <0-15>


UsethethresholdssnrmargincommandtoconfiguretheSNRmarginthresholds

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssnrmargin<015>command.
(config-hdsl4 1/0/1)#thresholds snr-margin 10

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78923

2-2006

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

thresholds uas 15-minute <0-900>


Usethresholdsuas15minutecommandtoconfigure15minuteUnavailableSecondsperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas15minute<0900>command.
(config-hdsl4 1/0/1)#thresholds uas 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78940

6TANV57CLI-35A

2-2007

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas 24-hour <0-86400>


Usethresholdsuas24hourcommandtoconfigure24hourUnavailableSecondsperformance
monitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas24hour<086400>command.
(config-hdsl4 1/0/1)#thresholds uas 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
78938

2-2008

6TANV57CLI-35A

Section 2, Commands - HDSL4 Interface Configuration Command Set

timeout loopback [2-hour|none]


Usethetimeoutcommandtoconfigureatimeoutusedtoautomaticallyremoveanyactive
loopbackortestpatternontheHDSL4interface.Usethenoformofthiscommandtoreturn
thetimeouttoitsdefaultsetting.

Syntax Description
2hour

2HourTimeout

none

NoTimeout

Usage Examples
Thefollowingisanexampleofhowtousethetimeoutloopback[2hour|none]command.
(config-hdsl4 1/0/1)#timeout loopback 2-hour
(config-hdsl4 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV844(1200635G2)

Command ID
79217

6TANV57CLI-35A

2-2009

Total Access/NetVanta Carrier CLI Dictionary

IP Host Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface ip-host * <shelf/slot>
ChassisId(config-ip-host name x/x)#

ThefollowingisalistofcommandsavailableintheIPHostInterfaceConfiguration
CommandSet.
connectinterfacepackettiming<shelf/slot>
connectinterfacepseudowire[<shelf/slot/pwe>|<remoteindex>]
connectservice[mgcp|sip]
defaultgatewayA.B.C.D
domainlookup
domainnameWORD
exit
ipaddressA.B.C.DA.B.C.D
ipaddressdhcp
nameserverA.B.C.D
nameserverA.B.C.DA.B.C.D
shutdown

2-2010

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

connect interface packet-timing <shelf/slot>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144241

6TANV57CLI-35A

2-2011

Total Access/NetVanta Carrier CLI Dictionary

connect interface pseudowire [<shelf/slot/pwe>|<remoteindex>]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
141115

2-2012

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

connect service [mgcp|sip]


Syntax Description
mgcp

MGCPvoiceservice

sip

SIPvoiceservice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
141126

6TANV57CLI-35A

2-2013

Total Access/NetVanta Carrier CLI Dictionary

default-gateway A.B.C.D
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
95926

2-2014

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

domain-lookup
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95929

6TANV57CLI-35A

2-2015

Total Access/NetVanta Carrier CLI Dictionary

domain-name WORD
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95932

2-2016

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
103029

6TANV57CLI-35A

2-2017

Total Access/NetVanta Carrier CLI Dictionary

ip address A.B.C.D A.B.C.D


Syntax Description
A.B.C.D

IPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
95905

2-2018

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

ip address dhcp
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133188

6TANV57CLI-35A

2-2019

Total Access/NetVanta Carrier CLI Dictionary

name-server A.B.C.D
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95935

2-2020

6TANV57CLI-35A

Section 2, Commands - IP Host Interface Configuration Command Set

name-server A.B.C.D A.B.C.D


Syntax Description
A.B.C.D

IPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
120297

6TANV57CLI-35A

2-2021

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1),E1CEM32PortAM(1188801G1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS
4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
95907

2-2022

6TANV57CLI-35A

Section 2, Commands - IPACL Configuration Command Set

IPACL Configuration Command Set


UsetheIPACLConfigurationcommandsettoconfiguretheIPAccessControlList.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#ip access-list standard WORD
ChassisId(config-mgmt-acl name)#

ThefollowingisalistofcommandsavailableintheIPACLConfigurationCommandSet.
exit
permitA.B.C.D
permitA.B.C.DA.B.C.D
permithostA.B.C.D

6TANV57CLI-35A

2-2023

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
78118

2-2024

6TANV57CLI-35A

Section 2, Commands - IPACL Configuration Command Set

permit A.B.C.D
UsethepermitA.B.C.Dcommandtopermitentrytotheroutingsystemforspecifiedpackets.

Usage Examples
ThefollowingisanexampleofhowtousethepermitA.B.C.Dcommand.
(config-mgmt-acl listname)#permit XX.XX.XX.XX
(config-mgmt-acl listname)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64147

6TANV57CLI-35A

2-2025

Total Access/NetVanta Carrier CLI Dictionary

permit A.B.C.D A.B.C.D


UsethepermitA.B.C.DA.B.C.Dtoaddthegivenipaddressandnetmasktothespecified
accesscontrollist.Usethenofromtoremovetheipaddressfromtheaccesscontrollist.

Syntax Description
A.B.C.D

Addresstomatch

Usage Examples
ThefollowingisanexampleofhowtousethepermitA.B.C.DA.B.C.Dcommand.
(config-mgmt-acl List1)#permit 1.2.3.4 255.255.255.0
(config-mgmt-acl List1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64149

2-2026

6TANV57CLI-35A

Section 2, Commands - IPACL Configuration Command Set

permit host A.B.C.D


UsethepermithostA.B.C.Dcommandtopermitaspecifiedhost.

Usage Examples
ThefollowingisanexampleofhowtousethepermithostA.B.C.Dcommand.
(config-mgmt-acl listname)#permit host XX.XX.XX.XX
(config-mgmt-acl listname)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64155

6TANV57CLI-35A

2-2027

Total Access/NetVanta Carrier CLI Dictionary

Line Admin Configuration Command Set


UsetheLineAdmincommandsettoconfigureAdminportsettings.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#line admin <0>
ChassisId(config-adminx)#

ThefollowingisalistofcommandsavailableintheLineAdminConfigurationCommandSet.
dcd
dtr
exit
flowcontrol[hardware|none]
mode[cli|menus|terminalserver|tl1|tl1test]
speed[115200|19200|38400|57600|9600]

2-2028

6TANV57CLI-35A

Section 2, Commands - Line Admin Configuration Command Set

dcd
UsethedcdcommandtoenableportlogoffwhenDCDislost.Usethenoformtodisableport
logoffwhenDCDislost.

Usage Examples
Thefollowingisanexampleofhowtousethedcdcommand.
(config-admin0)#dcd
(config-admin0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64056

6TANV57CLI-35A

2-2029

Total Access/NetVanta Carrier CLI Dictionary

dtr
UsethedtrcommandtodeassertDTRwhentheuserhasloggedoutoftheport.Usetheno
formtodisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousethedtrcommand.
(config-admin0)#dtr
(config-admin0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64058

2-2030

6TANV57CLI-35A

Section 2, Commands - Line Admin Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
78114

6TANV57CLI-35A

2-2031

Total Access/NetVanta Carrier CLI Dictionary

flow-control [hardware|none]
Usetheflowcontrolcommandtosetflowcontrolforthelineadminport.Usethenoformof
thiscommandtoreturntothedefaultsetting.

Syntax Description
hardware

EnableRTS/CTShardwarehandshaking

none

Disableallflowcontrol

Usage Examples
Thefollowingisanexampleofhowtousetheflowcontrol[hardware|none]command.
(config)#line admin 0
(config-config-admin0)#flow-control none

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64060

2-2032

6TANV57CLI-35A

Section 2, Commands - Line Admin Configuration Command Set

mode [cli|menus|terminal-server|tl1|tl1-test]
Usethemode[cli|menus|terminalserver|tl1|tl1test]tosettheoperatingmodeoftheport.
Usethenocommandtosetthemodetothedefaultvalue.

Syntax Description
cli

PresentaCommandLineInterface

menus

Presentamenusession

terminalserver

Actasterminalserver

tl1

PresentaTL1session

tl1test

UnauthenticatedTL1access

Usage Examples
Thefollowingisanexampleofhowtousethemode[cli|menus|terminalserver|tl1|tl1test]
command.
(config-admin0)#mode cli
(config-admin0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64046

6TANV57CLI-35A

2-2033

Total Access/NetVanta Carrier CLI Dictionary

speed [115200|19200|38400|57600|9600]
UsethespeedcommandtospecifythedataratefortheCONSOLEport.Thissettingmust
matchyourVT100terminalemulatororemulatorsoftware.Usethenoformofthiscommand
torestorethedefaultvalue.UsageExamplesThefollowingexampleconfigurestheCONSOLE
portfor19,200bps:(config)#lineconsole0(configcon0)#speed19200

Syntax Description
115200

Configurethelineadminportfor115200bpsoperation

19200

Configurethelineadminportfor19200bpsoperation

38400

Configurethelineadminportfor38400bpsoperation

57600

Configurethelineadminportfor57600bpsoperation

9600

Configurethelineadimportfor9600bpsoperation

Usage Examples
Thefollowingisanexampleofhowtousethespeed[115200|19200|38400|57600|9600]
command.
(config-admin0)#speed 9600
(config-admin0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65382

2-2034

6TANV57CLI-35A

Section 2, Commands - Line Console Configuration Command Set

Line Console Configuration Command Set


UsetheLineConsolecommandsettoconfigureconsoleportsettings.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#line console <0>
ChassisId(config-conx)#

ThefollowingisalistofcommandsavailableintheLineConsoleConfigurationCommand
Set.
descriptionLINE
dtr
exit
speed[115200|19200|38400|57600|9600|auto]

6TANV57CLI-35A

2-2035

Total Access/NetVanta Carrier CLI Dictionary

description LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105118

2-2036

6TANV57CLI-35A

Section 2, Commands - Line Console Configuration Command Set

dtr
UsethedtrcommandtologofftheuserwhenDTRislost/deasserted.Usethenoformto
disableloggoffwhenDTRislost/deasserted.

Usage Examples
Thefollowingisanexampleofhowtousethedtrcommand.
(config-con0)#dtr
(config-con0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64070

6TANV57CLI-35A

2-2037

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
78111

2-2038

6TANV57CLI-35A

Section 2, Commands - Line Console Configuration Command Set

speed [115200|19200|38400|57600|9600|auto]
Usethespeedcommandtospecifythedataratefortheconsoleport.Ifthespeedrateisnot
settoauto,thissettingmustmatchtheVT100terminalemulatororemulatorsoftware.When
settoauto,theconsoleportautobaudstomatchtherateoftheconnectedterminalprogram.

Syntax Description
115200

Configurethelineconsoleportfor115200bpsoperation

19200

Configurethelineconsoleportfor19200bpsoperation

38400

Configurethelineconsoleportfor38400bpsoperation

57600

Configurethelineconsoleportfor57600bpsoperation

9600

Configurethelineconsoleportfor9600bpsoperation

auto

Configurethelineconsoleportforautomaticspeeddetection

Usage Examples
Thefollowingisanexampleofhowtousethespeed[115200|19200|38400|57600|9600|auto]
command.
(config-con 0)#speed 9600

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64066

6TANV57CLI-35A

2-2039

Total Access/NetVanta Carrier CLI Dictionary

Line Network Configuration Command Set


UsetheLineNetworkcommandsettoconfigureNetworkManagementportsettings.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#line network <0>
ChassisId(config-netx)#

ThefollowingisalistofcommandsavailableintheLineNetworkConfigurationCommand
Set.
exit
mode[accessoryoption|cli|menus|terminalserver|tl1]
speed[115200|19200|38400|57600|9600]

2-2040

6TANV57CLI-35A

Section 2, Commands - Line Network Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
78113

6TANV57CLI-35A

2-2041

Total Access/NetVanta Carrier CLI Dictionary

mode [accessory-option|cli|menus|terminal-server|tl1]
Usethemode[accessoryoption|cli|menus|terminalserver|tl1]tosettheoperatingmodeof
theport.Usethenocommandtosetthemodetothedefaultvalue.

Syntax Description
accessoryoption

Accessorydevicemanagement

cli

PresentaCommandLineInterface

menus

Presentamenusession

terminalserver

Actasterminalserver

tl1

PresentaTL1session

Usage Examples
Thefollowingisanexampleofhowtousethemode[accessoryoption|cli|menus|terminal
server|tl1]command.
(config-net0)#mode cli
(config-net0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63992

2-2042

6TANV57CLI-35A

Section 2, Commands - Line Network Configuration Command Set

speed [115200|19200|38400|57600|9600]
UsethespeedcommandtospecifythedataratefortheNetworkport.Thissettingmustmatch
yourVT100terminalemulatororemulatorsoftware.Usethenoformofthiscommandto
restorethedefaultvalue.

Syntax Description
115200

Configurethelinenetworkportfor115200bpsoperation

19200

Configurethelinenetworkportfor19200bpsoperation

38400

Configurethelinenetworkportfor38400bpsoperation

57600

Configurethelinenetworkportfor57600bpsoperation

9600

Configurethelinenetworkportfor9600bpsoperation

Usage Examples
Thefollowingisanexampleofhowtousethespeed[115200|19200|38400|57600|9600]
command.
(config-net0)#speed 9600
(config-net0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
65375

6TANV57CLI-35A

2-2043

Total Access/NetVanta Carrier CLI Dictionary

Link Aggregation Group Interface Configuration Command


Set
UsetheLinkAggregationGroupInterfaceConfigurationCommandSettoconfigureavirtual
linkaggregationinterfaceasdefinedbyIEEE802.3ad
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface lag-group <shelf/slot/group>
ChassisId(config-lag-group name)#

ThefollowingisalistofcommandsavailableintheLinkAggregationGroupInterfaceConfig
urationCommandSet.
activelinksminimum<1n>
alarmenableactivelinksminimum
aliasWORD
exit
linkgigabitethernet<shelf/slot/port>
linktengigabitethernet<shelf/slot/port>
shutdown
shutdownunassigned

2-2044

6TANV57CLI-35A

Section 2, Commands - Link Aggregation Group Interface Configuration Command Set

active-links-minimum <1-n>
Usetheactivelinksminimumcommandtospecifytheminimumnumberoflinksrequiredto
beupforalinkaggregationgroup.Ifthenumberoflinkactiveislessthanthevaluefor
activelinksminimum,aredundancyfailovershouldoccur.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83098

6TANV57CLI-35A

2-2045

Total Access/NetVanta Carrier CLI Dictionary

alarm enable active-links-minimum


Usethealarmenablecommandtoallowtheactivelinksminimumalarmtobegenerated
whenthenumberofactivelinksislessthantheactivelinksminimumvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87767

2-2046

6TANV57CLI-35A

Section 2, Commands - Link Aggregation Group Interface Configuration Command Set

alias WORD
UsethealiasWORDcommandtospecifyacharacternameforalinkaggregationgroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83094

6TANV57CLI-35A

2-2047

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83092

2-2048

6TANV57CLI-35A

Section 2, Commands - Link Aggregation Group Interface Configuration Command Set

link gigabit-ethernet <shelf/slot/port>


Usethelinkgigabitethernetcommandtoaddthespecifiedgigabitethernetinterface(ie1/A/
1)tothelinkaggregationgroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83134

6TANV57CLI-35A

2-2049

Total Access/NetVanta Carrier CLI Dictionary

link ten-gigabit-ethernet <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
83135

2-2050

6TANV57CLI-35A

Section 2, Commands - Link Aggregation Group Interface Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisablethegroup(nodataispassed
through).Usethenoshutdowncommandtoenablethegroupandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the group:
(config-lag-group1)#shutdown
(config-lag-group1)#
! To enable the group:
(config-lag-group1)#no shutdown
(config-lag-group1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
83089

6TANV57CLI-35A

2-2051

Total Access/NetVanta Carrier CLI Dictionary

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisablethegroup(nodatais
passedthrough).Usethenoshutdowncommandtoenablethegroupandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
! To disable the group:
(config-lag-group1)#shutdown unassigned
(config-lag-group1)#
! To enable the group:
(config-lag-group1)#no shutdown
(config-lag-group1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
94325

2-2052

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

Muxponder Highspeed Interface Configuration Command


Set
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface ten-gigabit-ethernet <shelf/slot/port>
ChassisId(config-ten-giga-eth x/x/x)#

ThefollowingisalistofcommandsavailableintheMuxponderHighspeedInterfaceConfigu
rationCommandSet.
alarmenable[downstreamfault|heartbeatloss|lacptimeout|linkdownenterprise|link
downrfc2863|portmode|upstreamnode]
alarmenablepluggable[fault|missing|speedmismatch|temperaturehigh|unknown]
alarmenableshutdownmaintenance
descriptionLINE
downlink
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORDdown
ethernetoamenable
exit
lacpgrammarstandbyaggregation
lacpmode[active|passive]
mtu<150010000>
shutdown[maintenance|unassigned]
stagdei
subtendedhostipaddressA.B.C.DA.B.C.D
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD
subtendedhostsnmpservercommunityreadwriteWORD
subtendedhoststag[<14094>|systemmanagementevc]
subtendedhoststagpriority<07>
thresholdsbroadcasts15minute<04294967295>
thresholdsbroadcasts24hour<04294967295>
thresholdsdiscards15minute<04294967295>
thresholdsdiscards24hour<04294967295>
thresholdserrors15minute<04294967295>

6TANV57CLI-35A

2-2053

Total Access/NetVanta Carrier CLI Dictionary

thresholdserrors24hour<04294967295>
thresholdsgiants15minute<04294967295>
thresholdsgiants24hour<04294967295>
thresholdsmulticasts15minute<04294967295>
thresholdsmulticasts24hour<04294967295>
thresholdsrunts15minute<04294967295>
thresholdsrunts24hour<04294967295>

2-2054

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

alarm enable [downstream-fault|heartbeat-loss|lacptimeout|link-down-enterprise|link-down-rfc2863|portmode|upstream-node]


Syntax Description
downstreamfault

Downstreamnodeisinthenotreadystate

heartbeatloss

Treenetworkingheartbeatloss

lacptimeout

LACPtimeouthasoccured

linkdownenterprise

Enterpriselinkdownalarm

linkdownrfc2863

RFC2863linkdownalarm

portmode

Portmodedoesnotmatchconnecteddevice

upstreamnode

Upstreamnodecannotprocessprotectionmessages

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1)

Command ID
83041

6TANV57CLI-35A

2-2055

Total Access/NetVanta Carrier CLI Dictionary

alarm enable pluggable [fault|missing|speedmismatch|temperature-high|unknown]


Syntax Description
fault

Devicefault

missing

Missingdevice

speedmismatch

Speedcapabilitymismatch

temperaturehigh

Overtemperature

unknown

Unknowndevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
102018

2-2056

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
117287

6TANV57CLI-35A

2-2057

Total Access/NetVanta Carrier CLI Dictionary

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedtengigabitethernetinterface.Use
thenoformofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-ten-giga-eth 1/0/1)#description 10GE Port 1
(config-ten-giga-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78715

2-2058

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

downlink
UsethedownlinkcommandtosetthisinterfaceasadownlinktoanotherTotalAccess5000or
OSPDSLAM.ThisisusedinmultinodeorHDXapplicationsforredundancyandtiming
purposes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97309

6TANV57CLI-35A

2-2059

Total Access/NetVanta Carrier CLI Dictionary

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1)

Command ID
65068

2-2060

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

ethernet cfm enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
120315

6TANV57CLI-35A

2-2061

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm mep <1-8191> WORD WORD down


Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

WORD

NameofthemaintenanceassociationcontainingthisMEP

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65074

2-2062

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148042

6TANV57CLI-35A

2-2063

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78798

2-2064

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

lacp grammar standby-aggregation


Usethelacpgrammarstandbyaggregationcommandtospecifyhowastandbymodule
buildsLACPDUframes.Whenenabled,theaggregationbitisalwayssetonthestandby
moduleLACPDUs.Thesyncbitisusedtoindicatethattheactivemoduleisreadytoreceive
traffic.Whendisabled,theaggregationbitisusedtoindicatethatthestandbymoduleisready
toreceivetraffic.

Usage Examples
Thefollowingisanexampleofhowtousethelacpgrammarstandbyaggregationcommand.
(config-gig-eth 1/A/1)#lacp grammar standby-aggregation
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97303

6TANV57CLI-35A

2-2065

Total Access/NetVanta Carrier CLI Dictionary

lacp mode [active|passive]


Usethelacpmode[active|passive]commandtosettheLinkAggregationControlProtocol
(LACP)participationfortheselectedinterface.

Syntax Description
active

Activenegotiatingstate

passive

Passivenegotiatingstate

Usage Examples
Thefollowingisanexampleofhowtousethelacpmode[active|passive]command.
(config-gig-eth 1/A/1)# lacp mode active
(config-gig-eth 1/A/1)#

Functional Notes
LACPallowsanetworkdevicetonegotiateanautomaticbundlingoflinksbysendingLACP
packetstothepeer(directlyconnecteddevicethatalsoimplementsLACP).LACPworksby
sendingframes(LACPDUs)downalllinksthathavetheprotocolenabled.Ifadeviceis
presentontheotherendofthelinkthatalsohasLACPenabled,itwillalsoindependently
sendframesalongthesamelinksenablingthetwounitstodetectmultiplelinksbetween
themselvesandthencombinethemintoasinglelogicallink.LACPcanbeconfiguredinone
oftwomodes:ActiveorPassive.InActivemodeitwillalwayssendframesalongthe
configuredlinks.InPassivemodehowever,itactsasspeakwhenspokento,andtherefore
canbeusedasawayofcontrollingaccidentalloops(aslongastheotherdeviceisinactive
mode).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97299

2-2066

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

mtu <1500-10000>
Functional Notes
150010000isthestandardrange,butsomeproductsmaysupportasmallersubset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153980

6TANV57CLI-35A

2-2067

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-gig-eth 1/A/1)#shutdown
(config-gig-eth 1/A/1)#
! To disable the interface:
(config-gig-eth 1/A/1)#shutdown unassigned
(config-gig-eth 1/A/1)#
! To enable the interface:
(config-gig-eth 1/A/1)#no shutdown
(config-gig-eth 1/A/1)#
! To enable the interface but inhibit alarms:
(config-gig-eth 1/A/1)#shutdown maintenance
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

2-2068

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

Command ID
78693

6TANV57CLI-35A

2-2069

Total Access/NetVanta Carrier CLI Dictionary

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV8044
(1172804G1)

Command ID
98129

2-2070

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

subtended-host ip address A.B.C.D A.B.C.D


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148051

6TANV57CLI-35A

2-2071

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148054

2-2072

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148058

6TANV57CLI-35A

2-2073

Total Access/NetVanta Carrier CLI Dictionary

subtended-host mode [disabled|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148081

2-2074

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148071

6TANV57CLI-35A

2-2075

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148069

2-2076

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148067

6TANV57CLI-35A

2-2077

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag [<1-4094>|system-management-evc]


Syntax Description
<14094>

VIDoftheinbandmanagmentVlan

systemmanagementevc

InheritVIDfromtheSystemManagementEVC

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148059

2-2078

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148063

6TANV57CLI-35A

2-2079

Total Access/NetVanta Carrier CLI Dictionary

thresholds broadcasts 15-minute <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65059

2-2080

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds broadcasts 24-hour <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65061

6TANV57CLI-35A

2-2081

Total Access/NetVanta Carrier CLI Dictionary

thresholds discards 15-minute <0-4294967295>


Usethethresholdsdiscards15minute*commandtoconfigurethediscardedframecount
alarmthresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65049

2-2082

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds discards 24-hour <0-4294967295>


Usethethresholdsdiscards24hour*commandtoconfigurethediscardedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65051

6TANV57CLI-35A

2-2083

Total Access/NetVanta Carrier CLI Dictionary

thresholds errors 15-minute <0-4294967295>


Usethethresholdserrors15minute*commandtoconfiguretheCRCerrorcountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65034

2-2084

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds errors 24-hour <0-4294967295>


Usethethresholdserrors24hour*commandtoconfiguretheCRCerrorcountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65036

6TANV57CLI-35A

2-2085

Total Access/NetVanta Carrier CLI Dictionary

thresholds giants 15-minute <0-4294967295>


Usethethresholdsgiants15minute*commandtoconfiguretheoversizedframecountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65044

2-2086

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds giants 24-hour <0-4294967295>


Usethethresholdsgiants24hour*commandtoconfiguretheoversizedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65046

6TANV57CLI-35A

2-2087

Total Access/NetVanta Carrier CLI Dictionary

thresholds multicasts 15-minute <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65054

2-2088

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds multicasts 24-hour <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65056

6TANV57CLI-35A

2-2089

Total Access/NetVanta Carrier CLI Dictionary

thresholds runts 15-minute <0-4294967295>


Usethethresholdsrunts15minute*syntaxtoconfiguretheundersizedframecountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65039

2-2090

6TANV57CLI-35A

Section 2, Commands - Muxponder Highspeed Interface Configuration Command Set

thresholds runts 24-hour <0-4294967295>


Usethethresholdsrunts24hour*syntaxtoconfiguretheundersizedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65041

6TANV57CLI-35A

2-2091

Total Access/NetVanta Carrier CLI Dictionary

Muxponder Midspeed Interface Configuration Command


Set
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface muxponder-midspeed * gigabit-ethernet
ChassisId(config-muxpon-mid-giga-eth x/x/x)#

ThefollowingisalistofcommandsavailableintheMuxponderMidspeedInterfaceConfigu
rationCommandSet.
alarmenable[downstreamfault|heartbeatloss|lacptimeout|linkdownenterprise|link
downrfc2863|portmode|upstreamnode]
alarmenablepluggable[fault|missing|speedmismatch|temperaturehigh|unknown]
alarmenableshutdownmaintenance
descriptionLINE
downlink
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORD[down|up]
ethernetoamenable
exit
fullduplex
halfduplex
lacpgrammarstandbyaggregation
lacpmode[active|passive]
linkstateawareness
macagingtime<03600>
maclimit[<1n>|disabled]
mtu<150010000>
shutdown[maintenance|unassigned]
speed[10|100|1000|2500|auto]
stagdei
subtendedhostezprovisioning
subtendedhostipaddressA.B.C.DA.B.C.D
subtendedhostipaddressdhcp
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|listener|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD

2-2092

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtendedhostsnmpservercommunityreadwriteWORD
subtendedhostsnmpserverezprovisioninghostA.B.C.Dtrapsversion[1|2c]
subtendedhostsnmpserverlocationWORD
subtendedhoststag[<14094>|inherit]
subtendedhoststagpriority<07>
thresholdsbroadcasts15minute<04294967295>
thresholdsbroadcasts24hour<04294967295>
thresholdsdiscards15minute<04294967295>
thresholdsdiscards24hour<04294967295>
thresholdserrors15minute<04294967295>
thresholdserrors24hour<04294967295>
thresholdsgiants15minute<04294967295>
thresholdsgiants24hour<04294967295>
thresholdsinvalidvlan15minute<04294967295>
thresholdsinvalidvlan24hour<04294967295>
thresholdslinkstateawarenessbandwidthminimum<02147483647>
thresholdslinkstateawarenesslinksminimum<0n>
thresholdsmulticasts15minute<04294967295>
thresholdsmulticasts24hour<04294967295>
thresholdspeakmacentries15minute<0n>
thresholdspeakmacentries24hour<0n>
thresholdsrunts15minute<04294967295>
thresholdsrunts24hour<04294967295>

6TANV57CLI-35A

2-2093

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [downstream-fault|heartbeat-loss|lacptimeout|link-down-enterprise|link-down-rfc2863|portmode|upstream-node]


Usethealarmenablecommandtoallowthelistedgigabitethernetinterfacealarmstobe
generatedwhentheerrorconditionsarepresent.

Syntax Description
downstreamfault

Downstreamnodeisinthenotreadystate

heartbeatloss

Treenetworkingheartbeatloss

lacptimeout

LACPtimeouthasoccured

linkdownenterprise

Enterpriselinkdownalarm

linkdownrfc2863

RFC2863linkdownalarm

portmode

Portmodedoesnotmatchconnecteddevice

upstreamnode

Upstreamnodecannotprocessprotectionmessages

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),QuadGigELM(1187551E1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1)

Command ID
78019

2-2094

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

alarm enable pluggable [fault|missing|speedmismatch|temperature-high|unknown]


Syntax Description
fault

Devicefault

missing

Missingdevice

speedmismatch

Speedcapabilitymismatch

temperaturehigh

Overtemperature

unknown

Unknowndevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
101980

6TANV57CLI-35A

2-2095

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
111846

2-2096

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedbackplaneinterface.Usetheno
formofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-gig-eth 1/0/2)#description Gig Eth Port #2
(config-gig-eth 1/0/2)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78719

6TANV57CLI-35A

2-2097

Total Access/NetVanta Carrier CLI Dictionary

downlink
UsethedownlinkcommandtosetthisinterfaceasadownlinktoanotherTotalAccess5000or
OSPDSLAM.ThisisusedinmultinodeorHDXapplicationsforredundancyandtiming
purposes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
87730

2-2098

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64552

6TANV57CLI-35A

2-2099

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm enable


UsetheethernetcfmenablecommandtoenabletheethernetOAMconnectivityfault
managementsubsystemandallocateresources.Usethenoformofthiscommandtodisable
thesubsystem,causingallCFMfunctionstoceaseanddeallocateresources.Anyexisting
CFMconfigurationisretained,butnoframesaresentorreceivedandnoresourcesare
consumedotherthanspaceintheconfiguration.

Usage Examples
Thefollowingisanexampleofhowtousetheethernetcfmenablecommand.
! To enable the ethernet OAM connectivity fault management subsystem:
(config-gig-eth 1/0/1)#ethernet cfm
(config-gig-eth 1/0/1)#
! To disable the ethernet OAM connectivity fault management subsystem:
(config-gig-eth 1/0/1)#no ethernet cfm
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
120312

2-2100

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

ethernet cfm mep <1-8191> WORD WORD [down|up]


Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

down

Facingthephysicalport

up

Facingtheswitchingelement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
64557

6TANV57CLI-35A

2-2101

Total Access/NetVanta Carrier CLI Dictionary

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
120330

2-2102

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78800

6TANV57CLI-35A

2-2103

Total Access/NetVanta Carrier CLI Dictionary

full-duplex
UsethefullduplexcommandtoconfiguretheEthernetportforfullduplexoperation.
Thisallowstheporttosendandreceivesimultaneously.

Functional Notes
Thefullduplexcommandhasnosubcommands.Thedefaultvalueisautowhichissetusing
thespeedcommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV8044(1172804G1)

Command ID
66282

2-2104

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

half-duplex
UsethehalfduplexcommandtoconfiguretheEthernetportforhalfduplexoperation.
Thisallowstheporttoeithersendorreceiveatanygivenmoment,butnotsimultaneously.

Functional Notes
Thehalfduplexcommandhasnosubcommands.Thedefaultvalueisautowhichissetusing
thespeedcommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV8044(1172804G1)

Command ID
66281

6TANV57CLI-35A

2-2105

Total Access/NetVanta Carrier CLI Dictionary

lacp grammar standby-aggregation


Usethelacpgrammarstandbyaggregationcommandtospecifyhowastandbymodule
buildsLACPDUframes.Whenenabled,theaggregationbitisalwayssetonthestandby
moduleLACPDUs.Thesyncbitisusedtoindicatethattheactivemoduleisreadytoreceive
traffic.Whendisabled,theaggregationbitisusedtoindicatethatthestandbymoduleisready
toreceivetraffic.

Usage Examples
Thefollowingisanexampleofhowtousethelacpgrammarstandbyaggregationcommand.
(config-gig-eth 1/A/1)#lacp grammar standby-aggregation
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87692

2-2106

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

lacp mode [active|passive]


Usethelacpmode[active|passive]commandtosettheLinkAggregationControlProtocol
(LACP)participationfortheselectedinterface.

Syntax Description
active

Activenegotiatingstate

passive

Passivenegotiatingstate

Usage Examples
Thefollowingisanexampleofhowtousethelacpmode[active|passive]command.
(config-gig-eth 1/A/1)# lacp mode active
(config-gig-eth 1/A/1)#

Functional Notes
LACPallowsanetworkdevicetonegotiateanautomaticbundlingoflinksbysendingLACP
packetstothepeer(directlyconnecteddevicethatalsoimplementsLACP).LACPworksby
sendingframes(LACPDUs)downalllinksthathavetheprotocolenabled.Ifadeviceis
presentontheotherendofthelinkthatalsohasLACPenabled,itwillalsoindependently
sendframesalongthesamelinksenablingthetwounitstodetectmultiplelinksbetween
themselvesandthencombinethemintoasinglelogicallink.LACPcanbeconfiguredinone
oftwomodes:ActiveorPassive.InActivemodeitwillalwayssendframesalongthe
configuredlinks.InPassivemodehowever,itactsasspeakwhenspokento,andtherefore
canbeusedasawayofcontrollingaccidentalloops(aslongastheotherdeviceisinactive
mode).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV8044(1172804G1)

Command ID
87332

6TANV57CLI-35A

2-2107

Total Access/NetVanta Carrier CLI Dictionary

link-state-awareness
UsethelinkstateawarenesscommandtoenablelinkstateawarenessfortheselectedGigabit
Ethernetport.ForEFMgroupbasedMENports,thelinkstateawarenessfeature,when
enabled,shutsdowntheGigabitEthernetportifalloftheMENportstowhichtrafficis
mappedbecomeunavailable.Usethenoformofthiscommandtodisablelinkstate
awareness.

Usage Examples
Thefollowingisanexampleofhowtousethelinkstateawarenesscommand.
(config-gig-eth 1/0/1)#link-state-awareness
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
44773

2-2108

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

mac aging-time <0-3600>


Usethemacagingtime<03600>commandtoconfiguretheMACagingtimeinseconds.
Value0forceslearnandlock.Minvalueis5secondsandmax3600seconds.

Usage Examples
Thefollowingisanexampleofhowtousethemacagingtime<03600>command.
838_112(config-gig-eth 1/0/1)#mac aging-time 1000
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89690

6TANV57CLI-35A

2-2109

Total Access/NetVanta Carrier CLI Dictionary

mac limit [<1-n>|disabled]


Syntax Description
<1n>

NumberofMACaddresses

disabled

DisableMAClimitingonthisinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44759

2-2110

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

mtu <1500-10000>
Functional Notes
150010000isthestandardrange,butsomeproductsmaysupportasmallersubset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV8044(1172804G1)

Command ID
104778

6TANV57CLI-35A

2-2111

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.Ifsupported,usetheshutdownunassignedcommandtodisabletheinterface.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-gig-eth 1/0/1)#shutdown
(config-gig-eth 1/0/1)#
! To disable the interface:
(config-gig-eth 1/0/1)#shutdown unassigned
(config-gig-eth 1/0/1)#
! To enable the interface:
(config-gig-eth 1/0/1)#no shutdown
(config-gig-eth 1/0/1)#
! To enable the interface but inhibit alarms:
(config-gig-eth 1/0/1)#shutdown maintenance
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigE
LM(1187551E1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),TA3002POTS2GE(1187602G2),TA3242POTS4

2-2112

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
78691

6TANV57CLI-35A

2-2113

Total Access/NetVanta Carrier CLI Dictionary

speed [10|100|1000|2500|auto]
UsethespeedcommandtoconfigurethespeedofanGigabitEthernetinterface.Usetheno
formofthiscommandtoreturntothedefaultvalue.

Syntax Description
10

Configurethegigabitethernetfor10Mbpsoperation

100

Configurethegigabitethernetfor100Mbpsoperation

1000

Configurethegigabitethernetfor1000Mbpsoperation

2500

Configurethegigabitethernetfor2500Mbpsoperation

auto

Enableautonegotiationofspeed

Usage Examples
Thefollowingisanexampleofhowtousethespeed[10|100|1000|2500|auto]command.
(config-gig-eth 1/0/1)#speed 100
(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA324E2POTS4GE(1287737G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA354E2POTS4
GE(1287704G1),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA372E8POTS4DS1PWE2GESBU(1287723G1),TA3512POTS1
GE(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),FIBERAM(1187552G1),QuadGigELM
(1187550G2),QuadGigELM(1187551E1),ActiveEth24PortAM(1187560F1),SM2GE
(1187020G1),SM2GE(1187020G2),QuadGigELM(1187550E1),SM(1187020E1),SM
(1187020L1),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

2-2114

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

Command ID
44751

6TANV57CLI-35A

2-2115

Total Access/NetVanta Carrier CLI Dictionary

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
95501

2-2116

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host ez-provisioning
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138293

6TANV57CLI-35A

2-2117

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip address A.B.C.D A.B.C.D


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipaddressA.B.C.DA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip address 192.168.0.2
255.255.255.0

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
104997

2-2118

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host ip address dhcp


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ActiveEth24PortAM(1187560F1)

Command ID
142855

6TANV57CLI-35A

2-2119

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Usage Examples
ThefollowingisanexampleofhowtousethesubtendedhostipdefaultgatewayA.B.C.D
command.
(config-efm-group 1/18/1)#subtended-host ip default-gateway 192.168.0.254

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
104999

2-2120

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Usage Examples
Thefollowingisanexampleofhowtousethesubtendedhostipfileserverdefaulthost
A.B.C.Dcommand.
(config-efm-group 1/18/1)#subtended-host ip file-server default host
192.168.0.1

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105003

6TANV57CLI-35A

2-2121

Total Access/NetVanta Carrier CLI Dictionary

subtended-host mode [disabled|listener|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

listener

Acceptssubtendedhostparametersfromconnecteddevice

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105017

2-2122

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105016

6TANV57CLI-35A

2-2123

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105014

2-2124

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
105012

6TANV57CLI-35A

2-2125

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server ez-provisioning host A.B.C.D


traps version [1|2c]
Syntax Description
A.B.C.D

IPaddress

Version1

2c

Version2c

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138283

2-2126

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host snmp-server location WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
138292

6TANV57CLI-35A

2-2127

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag [<1-4094>|inherit]


Syntax Description
<14094>

VIDoftheinbandmanagmentVlan

inherit

InheritVIDfromtheSystemManagementEVC

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
105004

2-2128

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),ActiveEth24PortAM(1187560F1),10GEthernetMuxponder
(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
105008

6TANV57CLI-35A

2-2129

Total Access/NetVanta Carrier CLI Dictionary

thresholds broadcasts 15-minute <0-4294967295>


Usethethresholdsbroadcasts15minute<04294967295>commandtoconfigurethealarm
thresholdforbroadcastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds broadcasts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44831

2-2130

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds broadcasts 24-hour <0-4294967295>


Usethethresholdsbroadcasts24hour<04294967295>commandtoconfigurethealarm
thresholdforbroadcastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsbroadcasts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds broadcasts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44833

6TANV57CLI-35A

2-2131

Total Access/NetVanta Carrier CLI Dictionary

thresholds discards 15-minute <0-4294967295>


Usethethresholdsdiscards15minute<04294967295>commandtoconfigurethealarm
thresholdforframesdiscardedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds discards 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44811

2-2132

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds discards 24-hour <0-4294967295>


Usethethresholdsdiscards24hour<04294967295>commandtoconfigurethealarm
thresholdforframesdiscardedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsdiscards24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds discards 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44813

6TANV57CLI-35A

2-2133

Total Access/NetVanta Carrier CLI Dictionary

thresholds errors 15-minute <0-4294967295>


Usethethresholdserrors15minute<04294967295>commandtoconfigurethealarm
thresholdforCRCerrorsthatoccurina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds errors 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44781

2-2134

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds errors 24-hour <0-4294967295>


Usethethresholdserrors24hour<04294967295>commandtoconfigurethealarmthreshold
forCRCerrorsthatoccurina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdserrors24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds errors 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44783

6TANV57CLI-35A

2-2135

Total Access/NetVanta Carrier CLI Dictionary

thresholds giants 15-minute <0-4294967295>


Usethethresholdsgiants15minute<04294967295>commandtoconfigurethealarm
thresholdforoversizeframesthatoccurina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds giants 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44801

2-2136

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds giants 24-hour <0-4294967295>


Usethethresholdsgiants24hour<04294967295>commandtoconfigurethealarmthreshold
foroversizeframesthatoccurina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgiants24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds giants 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44803

6TANV57CLI-35A

2-2137

Total Access/NetVanta Carrier CLI Dictionary

thresholds invalid-vlan 15-minute <0-4294967295>


Usethethresholdsinvalidvlan15minute<04294967295>commandtoconfigurethealarm
thresholdforframeswithinvalidVLANreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds invalid-vlan 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82033

2-2138

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds invalid-vlan 24-hour <0-4294967295>


Usethethresholdsinvalidvlan24hour<04294967295>commandtoconfigurethealarm
thresholdforframeswithinvalidVLANreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsinvalidvlan24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds invalid-vlan 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82035

6TANV57CLI-35A

2-2139

Total Access/NetVanta Carrier CLI Dictionary

thresholds link-state-awareness bandwidth-minimum <02147483647>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142689

2-2140

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds link-state-awareness links-minimum <0-n>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
142691

6TANV57CLI-35A

2-2141

Total Access/NetVanta Carrier CLI Dictionary

thresholds multicasts 15-minute <0-4294967295>


Usethethresholdsmulticasts15minute<04294967295>commandtoconfigurethealarm
thresholdformulticastframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts15minute<0
4294967295>command.
(config-gig-eth 1/0/1)#thresholds multicasts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44821

2-2142

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds multicasts 24-hour <0-4294967295>


Usethethresholdsmulticasts24hour<04294967295>commandtoconfigurethealarm
thresholdformulticastframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsmulticasts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds multicasts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44823

6TANV57CLI-35A

2-2143

Total Access/NetVanta Carrier CLI Dictionary

thresholds peak-mac-entries 15-minute <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries15minute<0n>
command.
838_112(config-gig-eth 1/0/1)#thresholds peak-mac-entries 15-minute 40
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89706

2-2144

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds peak-mac-entries 24-hour <0-n>


UsethiscommandtosetthemaximumMACentriesthreshold.Oncethisthresholdexceedsa
TCAwillbereported.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdspeakmacentries24hour<0n>
command.
838_112(config-gig-eth 1/0/1)#thresholds peak-mac-entries 24-hour 70
838_112(config-gig-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89708

6TANV57CLI-35A

2-2145

Total Access/NetVanta Carrier CLI Dictionary

thresholds runts 15-minute <0-4294967295>


Usethethresholdsrunts15minute<04294967295>commandtoconfigurethealarm
thresholdforundersizedframesreceivedina15minuteinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts15minute<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds runts 15-minute 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44791

2-2146

6TANV57CLI-35A

Section 2, Commands - Muxponder Midspeed Interface Configuration Command Set

thresholds runts 24-hour <0-4294967295>


Usethethresholdsrunts24hour<04294967295>commandtoconfigurethealarmthreshold
forundersizedframesreceivedina24hourinterval.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsrunts24hour<04294967295>
command.
(config-gig-eth 1/0/1)#thresholds runts 24-hour 1000
(config-gig-eth 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
FIBERAM(1187552G1),QuadGigELM(1187550E1),QuadGigELM(1187550G2),ActiveEth
24PortAM(1187560F1),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP
(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
44793

6TANV57CLI-35A

2-2147

Total Access/NetVanta Carrier CLI Dictionary

ONT Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#remote-device ont {}
ChassisId(config-ont x/x/x)#

ThefollowingisalistofcommandsavailableintheONTConfigurationCommandSet.
aes
batterymonitoring
descriptionLINE
exit
registrationidLINE
serialnumberLINE
shutdown[maintenance|unassigned]

2-2148

6TANV57CLI-35A

Section 2, Commands - ONT Configuration Command Set

aes
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GE
RF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
139108

6TANV57CLI-35A

2-2149

Total Access/NetVanta Carrier CLI Dictionary

battery-monitoring
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133202

2-2150

6TANV57CLI-35A

Section 2, Commands - ONT Configuration Command Set

description LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133197

6TANV57CLI-35A

2-2151

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
134658

2-2152

6TANV57CLI-35A

Section 2, Commands - ONT Configuration Command Set

registration-id LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GE
RF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
133199

6TANV57CLI-35A

2-2153

Total Access/NetVanta Carrier CLI Dictionary

serial-number LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GE
RF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
133201

2-2154

6TANV57CLI-35A

Section 2, Commands - ONT Configuration Command Set

shutdown [maintenance|unassigned]
Syntax Description
shutdown

DisablethisONT(OutofServiceUnassigned)

maintenance

EnablethisONTwithalarmsuppression(OutofService
Maintenance)

unassigned

DisablethisONT(OutofServiceUnassigned)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4
GE(1287737G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1
PWE2GESBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
133191

6TANV57CLI-35A

2-2155

Total Access/NetVanta Carrier CLI Dictionary

Packet Timing Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface packet-timing <shelf/slot>
ChassisId(config-packet-timing x/x)#

ThefollowingisalistofcommandsavailableinthePacketTimingInterfaceConfiguration
CommandSet.
dscp<063>
exit
mode[client|server]
serveripaddressA.B.C.D
servermacaddressarp
shutdown
shutdownunassigned
type[inband|sntp|sntpinband]
uncorrelate

2-2156

6TANV57CLI-35A

Section 2, Commands - Packet Timing Interface Configuration Command Set

dscp <0-63>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144158

6TANV57CLI-35A

2-2157

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144169

2-2158

6TANV57CLI-35A

Section 2, Commands - Packet Timing Interface Configuration Command Set

mode [client|server]
Syntax Description
client

Clientmode

server

Servermode

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144150

6TANV57CLI-35A

2-2159

Total Access/NetVanta Carrier CLI Dictionary

server ip address A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144165

2-2160

6TANV57CLI-35A

Section 2, Commands - Packet Timing Interface Configuration Command Set

server mac-address arp


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144167

6TANV57CLI-35A

2-2161

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144160

2-2162

6TANV57CLI-35A

Section 2, Commands - Packet Timing Interface Configuration Command Set

shutdown unassigned
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144161

6TANV57CLI-35A

2-2163

Total Access/NetVanta Carrier CLI Dictionary

type [inband|sntp|sntp-inband]
Syntax Description
inband

Inband

sntp

SimpleNetworkTimeProtocol

sntpinband

BothSimpleNetworkTimeProtocolandInband

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144153

2-2164

6TANV57CLI-35A

Section 2, Commands - Packet Timing Interface Configuration Command Set

uncorrelate
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
144159

6TANV57CLI-35A

2-2165

Total Access/NetVanta Carrier CLI Dictionary

Policer Configuration Command Set


UsethePolicerConfigurationCommandSettocreateormodifyapolicerusedtolimit
bandwidthinspecifiedtrafficflows.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#policer * <shelf/slot>
ChassisId(config-policer name x/x)#

ThefollowingisalistofcommandsavailableinthePolicerConfigurationCommandSet.
cbs<0n>
cir<0n>
ebs<0n>
eir[<0n>|maxbandwidth]
exit
percustomevcmapWORD[egress|ingress]
perevcWORD
permevcWORD
permevcWORDcevlanpri<07>
peruniefmgroup<shelf/slot/group>
peruniethernet<shelf/slot/port>
perunigigabitethernet<shelf/slot/port>
perunimuxponderhighspeed<shelf/slot/port>
perunimuxpondermidspeed<shelf/slot/port>
shutdown
thresholdsgreendiscards15minute<04294967295>
thresholdsgreendiscards24hour<04294967295>
thresholdsgreentotal15minute<04294967295>
thresholdsgreentotal24hour<04294967295>
thresholdsredtotal15minute<04294967295>
thresholdsredtotal24hour<04294967295>
thresholdsyellowdiscards15minute<04294967295>
thresholdsyellowdiscards24hour<04294967295>
thresholdsyellowtotal15minute<04294967295>
thresholdsyellowtotal24hour<04294967295>

2-2166

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

cbs <0-n>
Usethecbs<0n>commandtoconfigurethecommittedburstsize(CBS)forthepolicer.The
CBSisthemaximumavailablebytesforaburstofingresstrafficsentattheUNIspeedwhile
stillconformingtotheCIR.UsethenoformofthiscommandtoreturntothedefaultCBS.

Usage Examples
Thefollowingisanexampleofhowtousethecbs<0n>command.
! Set the cbs to 2048 bytes.
(config-policer POL1)#cbs 2048
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40925

6TANV57CLI-35A

2-2167

Total Access/NetVanta Carrier CLI Dictionary

cir <0-n>
Usethecir<0n>commandtoconfigurethecommittedinformationrate(CIR)forthepolicer.
TheCIRistherateinkbpsuptowhichserviceframesaredeliveredaccordingtotheservice
performanceobjectives.UsethenoformofthiscommandtoreturntothedefaultCIR.

Usage Examples
Thefollowingisanexampleofhowtousethecir<0n>command.
! Set the CIR to 100 kbps.
(config-policer POL1)#cir 100
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40921

2-2168

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

ebs <0-n>
Usetheebs<0n>commandtoconfiguretheexcessburstsize(EBS)ofthepolicer.TheEBSis
themaximumavailablebytesforaburstofingresstrafficsentattheUNIspeedwhilestill
conformingtotheEIR.UsethenoformofthiscommandtousethedefaultEBS.

Usage Examples
Thefollowingisanexampleofhowtousetheebs<0n>command.
(config-policer POL1)#ebs 1024
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40927

6TANV57CLI-35A

2-2169

Total Access/NetVanta Carrier CLI Dictionary

eir [<0-n>|max-bandwidth]
Usetheeir[<0n>|maxbandwidth]commandtoconfiguretheexcessinformationrate(EIR)
forthepolicer.TheEIRistherateinkbpsuptowhichserviceframesaredeliveredwithout
anyperformanceobjectives.UsethenoformofthiscommandtousethedefaultEIR.

Syntax Description
<0n>

Rateinkbps

maxbandwidth

Allowalltrafficnotmarkedgreentobemarkedyellow

Usage Examples
Thefollowingisanexampleofhowtousetheeir[<0n>|maxbandwidth]command.
(config-policer POL1)#eir 500
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40922

2-2170

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Functional Notes
Theexitcommandhasnosubcommands.
Theexitcommandhasnodefaultvalues.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40928

6TANV57CLI-35A

2-2171

Total Access/NetVanta Carrier CLI Dictionary

per custom evc-map WORD [egress|ingress]


UsethepercustomevcmapWORD[egress|ingress]commandtoapplythepolicertoall
trafficonaparticularmap.Multiplemapscanbeaddedtoasinglepolicer.Usethenoformof
thiscommandtoremovethepolicerfromthemap.

Syntax Description
WORD

NameofEVCmap

egress

EVCegress

ingress

EVCingress

Usage Examples
ThefollowingisanexampleofhowtousethepercustomevcmapWORD[egress|ingress]
command.
(config-policer POL1)#per custom evc-map MAP1
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40903

2-2172

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

per evc WORD


UsetheperevcWORDcommandtoapplythepolicertoalltrafficonaparticularEVC.Use
thenoformofthiscommandtoremovethepolicerfromthetrafficontheEVC.

Usage Examples
ThefollowingisanexampleofhowtousetheperevcWORDcommand.
(config-policer POL1)#per evc EVC1
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40915

6TANV57CLI-35A

2-2173

Total Access/NetVanta Carrier CLI Dictionary

per mevc WORD


Functional Notes
UsethepermevcWORD?commandtoapplythepolicertoalltrafficonaparticularMEVC.
UsethenoformofthiscommandtoremovethepolicerfromthetrafficontheMEVC.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135983

2-2174

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

per mevc WORD ce-vlan-pri <0-7>


Syntax Description
WORD

Name

Functional Notes
UsethepermevcWORDcevlanpri<07>commandtoapplythepolicertoaparticularrange
ofCEVLANprioritytrafficwithinanMEVC.Usethenoformofthiscommandtoremovethe
policerfromtheCEVLANpriorityleveltraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135985

6TANV57CLI-35A

2-2175

Total Access/NetVanta Carrier CLI Dictionary

per uni efm-group <shelf/slot/group>


Usetheperuniefmgroup<shelf/slot/group>commandtoapplythepolicertoalltrafficona
particularUNIinterface.Usethenoformofthiscommandtoremovethepolicerfromthe
specifiedUNIinterfacetraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheperuniefmgroup<shelf/slot/group>
command.
(config-policer POL1)#per uni efm-group 1/0/1
(config-policer POL1)#

Functional Notes
ThisfunctioniscalledperIngressUNIinMEF10.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
40909

2-2176

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

per uni ethernet <shelf/slot/port>


Usetheperuniethernet<shelf/slot/port>commandtoapplythepolicertoalltrafficona
particularUNIinterface.UsethenoformofthiscommandtoremovethepolicerfromtheUNI
interfacetraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheperuniethernet<shelf/slot/port>command.
(config-policer POL1)#per uni ethernet 1/0/1
(config-policer POL1)#

Functional Notes
ThisfunctioniscalledperIngressUNIinMEF10.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
40911

6TANV57CLI-35A

2-2177

Total Access/NetVanta Carrier CLI Dictionary

per uni gigabit-ethernet <shelf/slot/port>


Usetheperunigigabitethernet<shelf/slot/port>commandtoapplythepolicertoalltraffic
onaparticularUNIinterface.Usethenoformofthiscommandtoremovethepolicerfromthe
UNIinterfacetraffic.

Usage Examples
Thefollowingisanexampleofhowtousetheperunigigabitethernet<shelf/slot/port>
command.
(config-policer POL1)#per uni gigabit-ethernet 1/0/1
(config-policer POL1)#

Functional Notes
ThisfunctioniscalledperIngressUNIinMEF10.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
40913

2-2178

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

per uni muxponder-highspeed <shelf/slot/port>


Functional Notes
Usetheperunimuxponderhighspeed<shelf/slot/port>commandtoapplythepolicertoall
trafficonaparticularUNIinterface.?Usethenoformofthiscommandtoremovethepolicer
fromtheUNIinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135981

6TANV57CLI-35A

2-2179

Total Access/NetVanta Carrier CLI Dictionary

per uni muxponder-midspeed <shelf/slot/port>


Functional Notes
Usetheperunimuxpondermidspeed<shelf/slot/port>commandtoapplythepolicertoall
trafficonaparticularUNIinterface.?Usethenoformofthiscommandtoremovethepolicer
fromtheUNIinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135979

2-2180

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisablethepolicer.Usethenoformofthis
commandtoenablethepolicer.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the policer:
(config-policer POL1)#shutdown
(config-policer POL1)#
! To enable the policer:
(config-policer POL1)#no shutdown
(config-policer POL1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1),ActiveEth24PortAM(1187560F1),10GEthernet
Muxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV
828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
40929

6TANV57CLI-35A

2-2181

Total Access/NetVanta Carrier CLI Dictionary

thresholds green-discards 15-minute <0-4294967295>


Usethethresholdsgreendiscards15minute<04294967295>commandtoconfigurethe15
minuteperformancemonitoringthresholdforgreenframesdroppedduetocongestion.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgreendiscards15minute<0
4294967295>command.
(config-policer POL1)#thresholds green-discards 15-minute 20
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82068

2-2182

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

thresholds green-discards 24-hour <0-4294967295>


Usethethresholdsgreendiscards24hour<04294967295>commandtoconfigurethe24hour
performancemonitoringthresholdforgreenframesdroppedduetocongestion.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgreendiscards24hour<0
4294967295>command.
(config-policer POL1)#thresholds green-discards 24-hour 100
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82070

6TANV57CLI-35A

2-2183

Total Access/NetVanta Carrier CLI Dictionary

thresholds green-total 15-minute <0-4294967295>


Usethethresholdsgreentotal15minute<04294967295>commandtoconfigurethe15
minuteperformancemonitoringthresholdforallingressframescoloredgreen.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgreentotal15minute<0
4294967295>command.
(config-policer POL1)#thresholds green-total 15-minute 20
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82073

2-2184

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

thresholds green-total 24-hour <0-4294967295>


Usethethresholdsgreentotal24hour<04294967295>commandtoconfigurethe24hour
performancemonitoringthresholdforallingressframescoloredgreen.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsgreentotal24hour<04294967295>
command.
(config-policer POL1)#thresholds green-total 24-hour 100
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82075

6TANV57CLI-35A

2-2185

Total Access/NetVanta Carrier CLI Dictionary

thresholds red-total 15-minute <0-4294967295>


Usethethresholdsredtotal15minute<04294967295>commandtoconfigurethe15minute
performancemonitoringthresholdforallingressframescoloredred.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsredtotal15minute<04294967295>
command.
(config-policer POL1)#thresholds red-total 15-minute 20
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82088

2-2186

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

thresholds red-total 24-hour <0-4294967295>


Usethethresholdsredtotal24hour<04294967295>commandtoconfigurethe24hour
performancemonitoringthresholdforallingressframescoloredred.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsredtotal24hour<04294967295>
command.
(config-policer POL1)#thresholds red-total 24-hour 100
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82090

6TANV57CLI-35A

2-2187

Total Access/NetVanta Carrier CLI Dictionary

thresholds yellow-discards 15-minute <0-4294967295>


Usethethresholdsyellowdiscards15minute<04294967295>commandtoconfigurethe15
minuteperformancemonitoringthresholdforyellowframesdroppedduetocongestion.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsyellowdiscards15minute<0
4294967295>command.
(config-policer POL1)#thresholds yellow-discards 15-minute 20
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82078

2-2188

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

thresholds yellow-discards 24-hour <0-4294967295>


Usethethresholdsyellowdiscards24hour<04294967295>commandtoconfigurethe24
hourperformancemonitoringthresholdforyellowframesdroppedduetocongestion.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsyellowdiscards24hour<0
4294967295>command.
(config-policer POL1)#thresholds yellow-discards 24-hour 100
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82080

6TANV57CLI-35A

2-2189

Total Access/NetVanta Carrier CLI Dictionary

thresholds yellow-total 15-minute <0-4294967295>


Usethethresholdsyellowtotal15minute<04294967295>commandtoconfigurethe15
minuteperformancemonitoringthresholdforallingressframescoloredyellow.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsyellowtotal15minute<0
4294967295>command.
(config-policer POL1)#thresholds yellow-total 15-minute 20
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82083

2-2190

6TANV57CLI-35A

Section 2, Commands - Policer Configuration Command Set

thresholds yellow-total 24-hour <0-4294967295>


Usethethresholdsyellowtotal24hour<04294967295>commandtoconfigurethe24hour
performancemonitoringthresholdforallingressframescoloredyellow.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsyellowtotal24hour<04294967295>
command.
(config-policer POL1)#thresholds yellow-total 24-hour 100
(config-policer POL1)#

Functional Notes
Thevalidrangeforthethresholdis04294967295.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82085

6TANV57CLI-35A

2-2191

Total Access/NetVanta Carrier CLI Dictionary

Power Shedding Configuration Command Set


UsethePowerSheddingcommandsettoconfigureparametersassociatedwithpower
shedding.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#power-shedding
ChassisId(config-pwr-shed)#

ThefollowingisalistofcommandsavailableinthePowerSheddingConfigurationCommand
Set.
activationdelay<11440>
alarmlevelpowershedstate[alert|critical|information|major|minor]
deactivationdelay<11440>
exit
shutdown
triggerexternalinput[<1n>|aco]
triggerremoteserver

2-2192

6TANV57CLI-35A

Section 2, Commands - Power Shedding Configuration Command Set

activation-delay <1-1440>
Usetheactivationdelay<11440>commandtosettheamountoftimebeforethepower
sheddingalarmisdeclared.Usethenoformtosetthedelaytothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousetheactivationdelay<11440>command.
(config-pwr-shed)#activation-delay 1440
(config-pwr-shed)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64103

6TANV57CLI-35A

2-2193

Total Access/NetVanta Carrier CLI Dictionary

alarm level power-shed-state


[alert|critical|information|major|minor]
Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
101591

2-2194

6TANV57CLI-35A

Section 2, Commands - Power Shedding Configuration Command Set

deactivation-delay <1-1440>
Usethedeactivationdelay<11440>commandtosettheamountoftimebeforethepower
sheddingalarmisdeactivateoncethealarmconditionhasclearedUsethenoformtosetthe
delaytothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethedeactivationdelay<11440>command.
(config-pwr-shed)#deactivation-delay 1440
(config-pwr-shed)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64112

6TANV57CLI-35A

2-2195

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80690

2-2196

6TANV57CLI-35A

Section 2, Commands - Power Shedding Configuration Command Set

shutdown
Usetheshutdowncommandtoadministrativelydisablethepowershedding.Usethenoform
ofthiscommandtoenablepowershedding.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable power shedding:
(config-pwr-shed)#shutdown
(config-pwr-shed)#
! To enable power shedding:
(config-pwr-shed)#no shutdown
(config-pwr-shed)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64116

6TANV57CLI-35A

2-2197

Total Access/NetVanta Carrier CLI Dictionary

trigger external-input [<1-n>|aco]


Syntax Description
<1n>

Inputnumber

aco

AlarmCutOff

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
101651

2-2198

6TANV57CLI-35A

Section 2, Commands - Power Shedding Configuration Command Set

trigger remote-server
UsethealarmacoinputcommandtosetthePowerSheddingAlarminputtotheacoinput.
UsethenofromtosetthePowerSheddingAlarminputtothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethetriggerremoteservercommand.
(config-pwr-shed)#alarm aco-input
(config-pwr-shed)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1)

Command ID
140392

6TANV57CLI-35A

2-2199

Total Access/NetVanta Carrier CLI Dictionary

PPP Group Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface ppp-group <shelf/slot/group>
ChassisId(config-ppp-group name)#

ThefollowingisalistofcommandsavailableinthePPPGroupInterfaceConfiguration
CommandSet.
acfc
activelinksminimum<1n>
aliasWORD
ethernetcfmenable
ethernetcfmmep<18191>WORDWORDup
exit
link[<slot/port>|<slot/port:chan>]
lqm
magicnumber
maxconfigure<230>
maxfailure<230>
maxterminate<230>
peerdefaultipaddressA.B.C.D
peerdefaultipdefaultgatewayA.B.C.D
peerdefaultipdhcpclientclientidWORD
peerdefaultipdhcpclientclientidWORDhostnameWORD
peerdefaultipdhcpclienthostnameWORD
peerdefaultipdnsA.B.C.D
peerdefaultipdnsA.B.C.DA.B.C.D
pfc
pppauthentication[chap|none]
pppchaphostnameWORD
pppchappasswordWORD
pppmultilink
restarttimer<130>
shutdown
shutdownunassigned
usernameWORD
usernameWORDpasswordWORD

2-2200

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

acfc
Usetheacfccommandtoenableaddresscontrolfieldcompression.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89319

6TANV57CLI-35A

2-2201

Total Access/NetVanta Carrier CLI Dictionary

active-links-minimum <1-n>
ThiscommandsetstheminimumnumberofactivelinksforanPPPGroup.Usethenoform
ofthiscommandtosettothedefaultvalue.

Functional Notes
Thedefaultis1

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104667

2-2202

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

alias WORD
UsethealiasWORDcommandtospecifyatextstringthatcanbeusedtoreferencethisPPP
group.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89284

6TANV57CLI-35A

2-2203

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm enable


UsetheethernetcfmcommandtoconfigureConnectivityFaultManagement.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
120317

2-2204

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

ethernet cfm mep <1-8191> WORD WORD up


Usetheethernetcfmmep<18191>WORDWORDupcommandtoconfigureConnectivity
FaultManagementbycreatingormodifyingaMaintenanceEndPoint(MEP)facingthe
switchingelement.

Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

WORD

NameofthemaintenanceassociationcontainingthisMEP

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89515

6TANV57CLI-35A

2-2205

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89285

2-2206

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

link [<slot/port>|<slot/port:chan>]
Usethelink<shelf/slot/port>commandtoaddppplinkstoaPPPGroup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89287

6TANV57CLI-35A

2-2207

Total Access/NetVanta Carrier CLI Dictionary

lqm
Usethelqmcommandtoenablelinkqualitymonitoringresponses

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89315

2-2208

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

magic-number
UsethemagicnumbercommandtoenabletheLinkControlProtocol(LCP)magicnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89313

6TANV57CLI-35A

2-2209

Total Access/NetVanta Carrier CLI Dictionary

max-configure <2-30>
Usethemaxconfigurecommandtospecifythemaximumnumberofconfigurerequest
packetssentwithoutreceivingaresponse.Validrangeis230.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89328

2-2210

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

max-failure <2-30>
Usethemaxfailurecommandtospecifythemaximumnumberofconfigurenakssent
withoutreceivingaconfigureack.Validrangeis230.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89331

6TANV57CLI-35A

2-2211

Total Access/NetVanta Carrier CLI Dictionary

max-terminate <2-30>
Usethemaxterminatecommandtospecifythemaximumnumberofterminaterequest
packetssentwithoutreceivingterminateack.Validrangeis230.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89325

2-2212

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

peer default ip address A.B.C.D


UsethepeerdefaultipaddressA.B.C.DcommandtoconfigurethedefaultIPAddress.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89307

6TANV57CLI-35A

2-2213

Total Access/NetVanta Carrier CLI Dictionary

peer default ip default-gateway A.B.C.D


UsethepeerdefaultipdefaultgatewayA.B.C.Dcommandtoconfigurethedefaultgateway.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89309

2-2214

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

peer default ip dhcp-client client-id WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104318

6TANV57CLI-35A

2-2215

Total Access/NetVanta Carrier CLI Dictionary

peer default ip dhcp-client client-id WORD hostname WORD


Syntax Description
WORD

ClientID

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104320

2-2216

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

peer default ip dhcp-client hostname WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
104322

6TANV57CLI-35A

2-2217

Total Access/NetVanta Carrier CLI Dictionary

peer default ip dns A.B.C.D


UsethepeerdefaultipdnsA.B.C.DcommandtoconfigureprimaryDNS.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89311

2-2218

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

peer default ip dns A.B.C.D A.B.C.D


UsethepeerdefaultipdnsA.B.C.DA.B.C.Dcommandtoconfigureprimaryandsecondary
DNS.

Syntax Description
A.B.C.D

PrimaryDNS

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89312

6TANV57CLI-35A

2-2219

Total Access/NetVanta Carrier CLI Dictionary

pfc
Usethepfccommandtoenableprotocolfieldcompression

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89317

2-2220

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

ppp authentication [chap|none]


Syntax Description
chap

ChallengeHandshakeAuthenticationProtocol

none

noauthentication

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103036

6TANV57CLI-35A

2-2221

Total Access/NetVanta Carrier CLI Dictionary

ppp chap hostname WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103050

2-2222

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

ppp chap password WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103043

6TANV57CLI-35A

2-2223

Total Access/NetVanta Carrier CLI Dictionary

ppp multilink
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103053

2-2224

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

restart-timer <1-30>
UsetherestarttimercommandtospecifythetimebeforerestartofLinkControlProtocol
(LCP)negotiation.Validrangeis130seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89322

6TANV57CLI-35A

2-2225

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the interface:
(config-ppp-group1)#shutdown
(config-ppp-group1)#
To enable the interface:
(config-ppp-group1)#no shutdown
(config-ppp-group1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
89303

2-2226

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

shutdown unassigned
Usetheshutdownunassignedcommandtoadministrativelydisabletheinterface(nodatais
passedthrough).Usethenoshutdowncommandtoenabletheinterfaceandallowittopass
data.Ifsupported,usetheshutdownmaintenancecommandtoenabletheinterfacebut
inhibitalarms.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdownunassignedcommand.
! To disable the interface:
(config-ppp-group1)#shutdown unassigned
(config-ppp-group1)#
! To enable the interface:
(config-ppp-group1)#no shutdown
(config-ppp-group1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
94335

6TANV57CLI-35A

2-2227

Total Access/NetVanta Carrier CLI Dictionary

username WORD
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103056

2-2228

6TANV57CLI-35A

Section 2, Commands - PPP Group Interface Configuration Command Set

username WORD password WORD


Syntax Description
WORD

Username

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1)

Command ID
103060

6TANV57CLI-35A

2-2229

Total Access/NetVanta Carrier CLI Dictionary

Protection Group Configuration Command Set


UsetheProtectionGroupConfigurationCommandSettocreateormodifyapairingofoneor
moreworkingmodulestooneormoreprotectmodules.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#protection-group <shelf/group>
ChassisId(config-prot-group name)#

Functional Notes
CommandsetforprotectionmodulessuchastheEFMProtectionModule
ThefollowingisalistofcommandsavailableintheProtectionGroupConfiguration
CommandSet.
addprotectmodule<slot>
addworkingmodule<slot>
aliasWORD
exit
inhibitswitch<slot>
priority<slot><1n>
revertive<slot>
waittorestoreautoswitch<120>
waittorestoremanualswitch<slot><110>

2-2230

6TANV57CLI-35A

Section 2, Commands - Protection Group Configuration Command Set

add protect-module <slot>


Thiscommandisusedtospecifythelocationoftheprotectionmodule.

Usage Examples
Thefollowingisanexampleofhowtousetheaddprotectmodule<slot>command.
(config-prot-group name)#add protect-module 11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1)

Command ID
46210

6TANV57CLI-35A

2-2231

Total Access/NetVanta Carrier CLI Dictionary

add working-module <slot>


Usethiscommandtoaddslotstoaprotectiongroup.Usethenoformofthiscommandto
removeslotsfromtheprotectiongroup.

Usage Examples
Thefollowingisanexampleofhowtousetheaddworkingmodule<slot>command.
(config-prot-group name)#add working-module 1-2

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM
(1188180E1),EFME1AM(1188802G1)

Command ID
46182

2-2232

6TANV57CLI-35A

Section 2, Commands - Protection Group Configuration Command Set

alias WORD
ThiscommandisusedtoassignanaliastoanEFMprotectiongroup.Usethenoformofthis
commandtosetthedefaultvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
88256

6TANV57CLI-35A

2-2233

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
80683

2-2234

6TANV57CLI-35A

Section 2, Commands - Protection Group Configuration Command Set

inhibit-switch <slot>
Usethiscommandtokeepaslotinsideofaprotectiongroupfrombeingprotectedbythe
ProtectionModule.Toenableprotectionusethenoformofthiscommand.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
46196

6TANV57CLI-35A

2-2235

Total Access/NetVanta Carrier CLI Dictionary

priority <slot> <1-n>


Usethepriority<slot><1n>commandtosetthepriorityofagivenslot.Thehighervaluehas
thehighpriority.Iftwoslotsneedprotectionatagiventime,thentheslotwiththehigher
priorityisprotected.Iftwoslotswiththesamepriorityneedprotection,thentheslotthatfails
firstisprotected.

Syntax Description
<slot>

Slottoapplyrankingwithinprotectiongroup

Usage Examples
Thefollowingisanexampleofhowtousethepriority<slot><1n>command.
(config-prot-group name)#priority 5 7
(config-prot-group name)#

Functional Notes
Thevalidrangeforthepriorityis1to32.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM
(1188180E1),EFME1AM(1188802G1)

Command ID
46187

2-2236

6TANV57CLI-35A

Section 2, Commands - Protection Group Configuration Command Set

revertive <slot>
Usetherevertive<slot>commandtostopanaccessmoduleinthespecifiedslotfromautomat
icallyrevertingbackonceithasswitchedtoaprotectmodule.Usethenoformofthis
commandtoreturntothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetherevertive<slot>command.
(config-prot-group name)#revertive 3
(config-prot-group name)#

Functional Notes
Usetheslotinputtoentertheslotnumberfortheworkingmodulethatisapartofthe
protectiongroup.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM
(1188180E1),EFME1AM(1188802G1)

Command ID
46191

6TANV57CLI-35A

2-2237

Total Access/NetVanta Carrier CLI Dictionary

wait-to-restore auto-switch <1-20>


Usethewaittorestoreautoswitch<120>commandtosettheamountoftimethesystem
waitstorevertbacktoaprotectedaccessmoduleonceitisavailable.Thiscommandisused
formodulesthatareautomaticallyprotected.Usethenoformofthiscommandtosetthe
defaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethewaittorestoreautoswitch<120>command.
(config-prot-group name)#wait-to-restore auto-switch 7
(config-prot-group name)#

Functional Notes
Thevalidrangeforthetimeis120minutes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMBondingProtectAM(1187250G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1)

Command ID
46180

2-2238

6TANV57CLI-35A

Section 2, Commands - Protection Group Configuration Command Set

wait-to-restore manual-switch <slot> <1-10>


Usethewaittorestoremanualswitch<slot><110>commandtosettheamountoftimethe
systemwaitstorevertbacktoaprotectedaccessmoduleonceitisavailable.Thiscommandis
usedformodulesthataremanuallyprotected.Usethenoformofthiscommandtosetthe
defaultsetting.

Syntax Description
<slot>

Enterworkingmoduleslot

Usage Examples
Thefollowingisanexampleofhowtousethewaittorestoremanualswitch<slot><110>
command.
(config-prot-group name)#wait-to-restore manual-switch 3 7
(config-prot-group name)#

Functional Notes
Thevalidrangeforthetimeis120minutes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM
(1188180E1),EFME1AM(1188802G1)

Command ID
46202

6TANV57CLI-35A

2-2239

Total Access/NetVanta Carrier CLI Dictionary

Pseudowire Circuit Emulation Interface Configuration


Command Set
UsetheVCLInterfaceConfigurationCommandSettoconfiguretheselectedATMlinks.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface pseudowire * cem
ChassisId(config-cem x/x/x)#

ThefollowingisalistofcommandsavailableinthePseudowireCircuitEmulationInterface
ConfigurationCommandSet.
connecte1<shelf/slot/port>
connectt1[<shelf/slot/port>|<remoteindex>]
descriptionLINE
destination[<shelf/slot/port>|<remoteindex>]
destinationipaddressA.B.C.D
destinationipudpport<n65535>
destinationmacaddressarp
dscp<063>
exit
jitterbufferdepth<1100>
mode[advanced|basic]
payloadsize<25958>
rtpfrequency<813200>
rtppayloadtype<96127>
shutdown[maintenance|unassigned]
sourceipudpport<n65535>
typesatop

2-2240

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

connect e1 <shelf/slot/port>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
133176

6TANV57CLI-35A

2-2241

Total Access/NetVanta Carrier CLI Dictionary

connect t1 [<shelf/slot/port>|<remote-index>]
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1)

Command ID
131141

2-2242

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

description LINE
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
133207

6TANV57CLI-35A

2-2243

Total Access/NetVanta Carrier CLI Dictionary

destination [<shelf/slot/port>|<remote-index>]
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131154

2-2244

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

destination ip address A.B.C.D


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131152

6TANV57CLI-35A

2-2245

Total Access/NetVanta Carrier CLI Dictionary

destination ip udp-port <n-65535>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
133289

2-2246

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

destination mac-address arp


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131153

6TANV57CLI-35A

2-2247

Total Access/NetVanta Carrier CLI Dictionary

dscp <0-63>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131156

2-2248

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

exit
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131177

6TANV57CLI-35A

2-2249

Total Access/NetVanta Carrier CLI Dictionary

jitter-buffer-depth <1-100>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131158

2-2250

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

mode [advanced|basic]
Syntax Description
advanced

UseIP/UDPparameters

basic

Usedeviceindexing

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131159

6TANV57CLI-35A

2-2251

Total Access/NetVanta Carrier CLI Dictionary

payload-size <25-958>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131163

2-2252

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

rtp frequency <8-13200>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131168

6TANV57CLI-35A

2-2253

Total Access/NetVanta Carrier CLI Dictionary

rtp payload-type <96-127>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1)

Command ID
131167

2-2254

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

shutdown [maintenance|unassigned]
Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131066

6TANV57CLI-35A

2-2255

Total Access/NetVanta Carrier CLI Dictionary

source ip udp-port <n-65535>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131172

2-2256

6TANV57CLI-35A

Section 2, Commands - Pseudowire Circuit Emulation Interface Configuration Command Set

type satop
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
E1CEM32PortAM(1188801G1),TA3728POTS4DS1PWE2GESBU(1287722G1),
TA372E8POTS4DS1PWE2GESBU(1287723G1)

Command ID
131174

6TANV57CLI-35A

2-2257

Total Access/NetVanta Carrier CLI Dictionary

Queue Configuration Command Set


Usethequeuecommandsettoconfigureaspecificqueuesparameters.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#queue interface efm-group * <0-n>
ChassisId(config-queue x iftype x/x/x)#

ThefollowingisalistofcommandsavailableintheQueueConfigurationCommandSet.
algorithm[sred|wred]
cos<07>
dropprobabilitygreen<0100>
dropprobabilityyellow<0100>
exit
maxdepth<1n>
thresholdssredgreenminimum<1255>
thresholdssredyellowminimum<1255>
thresholdswredgreenmaximum<1255>
thresholdswredgreenminimum<1255>
thresholdswredyellowmaximum<1255>
thresholdswredyellowminimum<1255>
weight[<1100>|dynamic]

2-2258

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

algorithm [sred|wred]

Syntax Description
sred

EnableSimpleRandomEarlyDiscard

wred

EnableWeightedRandomEarlyDetection

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550G2),SM2GE(1187020G1),SM2GE(1187020G2),EFMDS3CCAM
(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),EFMSHDSLAM
(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),10GEthernet
Muxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV8044(1172804G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65798

6TANV57CLI-35A

2-2259

Total Access/NetVanta Carrier CLI Dictionary

cos <0-7>
Usethecos<07>commandtosetthecosvaluetoaparticularqueue.Thisispartofthe
scheduler.Queueswiththesamecosvalueswillenabletheschedulertoschedulethepackets
betweenthesamecosqueuesusingWeightedDeficitRoundRobinalgorithm.

Usage Examples
Thefollowingisanexampleofhowtousethecos<07>command.
838_112(config-queue 0 ethernet 1/0/1)#cos 7
838_112(config-queue 0 ethernet 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

Command ID
90227

2-2260

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

drop-probability green <0-100>


Usethedropprobabilitygreen<0100>commandtosetthedropprobabilityofgreentraffic.
Usethenoformofthecommandtosetthedropprobabilitytoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethedropprobabilitygreen<0100>command.
(config-queue 1 ethernet 1/0/1)#drop-probability green 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthedropprobabilityis0100.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
QuadGigELM(1187550G2),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65803

6TANV57CLI-35A

2-2261

Total Access/NetVanta Carrier CLI Dictionary

drop-probability yellow <0-100>


Usethedropprobabilityyellow<0100>commandtosetthedropprobabilityofyellowtraffic.
Usethenoformofthecommandtosetthedropprobabilitytoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethedropprobabilityyellow<0100>command.
(config-queue 1 ethernet 1/0/1)#drop-probability yellow 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthedropprobabilityis0100.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
QuadGigELM(1187550G2),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65804

2-2262

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Functional Notes
Theexitcommandhasnosubcommands.
Theexitcommandhasnodefaultvalues.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
QuadGigELM(1187550G2),10GEthernetMuxponder(1174101F1),SM(1187020E1),SM
(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE
(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828
(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T
(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV
838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044
(1172804G1)

Command ID
65797

6TANV57CLI-35A

2-2263

Total Access/NetVanta Carrier CLI Dictionary

max-depth <1-n>
Usethiscommandtosetthemaximumnumberofframesthatcanbeinsertedintothisqueue.
Usethenoformofthiscommandtorestorethemaximumdepthtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethemaxdepth<1n>command.
838_112(config-queue 1 ethernet 1/0/1)#max-depth 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
QuadGigELM(1187550G2),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM
2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65834

2-2264

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

thresholds sred green minimum <1-255>


Usethethresholdswredgreenminimum<1255>commandtosetthecongestion
managementminimumthresholdsforgreentraffic.Usethenoformofthecommandtoset
thethresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssredgreenminimum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred green minimum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550G2),SM2GE(1187020G1),SM2GE(1187020G2),NV8044
(1172804G1)

Command ID
94189

6TANV57CLI-35A

2-2265

Total Access/NetVanta Carrier CLI Dictionary

thresholds sred yellow minimum <1-255>


Usethethresholdswredyellowminimum<1255>commandtosetthecongestion
managementminimumthresholdsforgreentraffic.Usethenoformofthecommandtoset
thethresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssredyellowminimum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred yellow minimum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550G2),SM2GE(1187020G1),SM2GE(1187020G2),NV8044
(1172804G1)

Command ID
94194

2-2266

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

thresholds wred green maximum <1-255>


Usethethresholdswredgreenmaximum<1255>commandtosetthecongestion
managementmaximumthresholdforgreentraffic.Usethenoformofthecommandtosetthe
thresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdswredgreenmaximum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred green maximum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65817

6TANV57CLI-35A

2-2267

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred green minimum <1-255>


Usethethresholdswredgreenminimum<1255>commandtosetthecongestion
managementminimumthresholdsforgreentraffic.Usethenoformofthecommandtoset
thethresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdswredgreenminimum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred green minimum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65812

2-2268

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

thresholds wred yellow maximum <1-255>


Usethethresholdswredgreenminimum<1255>commandtosetthecongestion
managementmaximumthresholdsforgreentraffic.Usethenoformofthecommandtoset
thethresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdswredyellowmaximum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred yellow maximum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65821

6TANV57CLI-35A

2-2269

Total Access/NetVanta Carrier CLI Dictionary

thresholds wred yellow minimum <1-255>


Usethethresholdswredyellowminimum<1255>commandtosetthecongestion
managementminimumthresholdsforgreentraffic.Usethenoformofthecommandtoset
thethresholdtoitsdefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdswredyellowminimum<1255>
command.
(config-queue 1 ethernet 1/0/1)#thresholds wred yellow minimum 20
(config-queue 1 ethernet 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis1255.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65819

2-2270

6TANV57CLI-35A

Section 2, Commands - Queue Configuration Command Set

weight [<1-100>|dynamic]
Syntax Description
<1100>

Weightasapercentage

dynamic

Dynamicweighting

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),EFME1AM(1188802G1),
10GEthernetMuxponder(1174101F1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

Command ID
65837

6TANV57CLI-35A

2-2271

Total Access/NetVanta Carrier CLI Dictionary

Redundancy Configuration Command Set


UsetheRedundancyConfigurationCommandSettoconfigureoptionsassociatedwith
redundantmodules
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#redundancy <shelf/slot>
ChassisId(config-redun x/x)#

ThefollowingisalistofcommandsavailableintheRedundancyConfigurationCommand
Set.
alarmenable[autoswitch|cardactive|databasesync|manualswitch|protection
unavailable|switchtoprotect]
alarmenablepeer[mirror|version]
exit
revertive
shutdown
waittorestore<1565535>

2-2272

6TANV57CLI-35A

Section 2, Commands - Redundancy Configuration Command Set

alarm enable [auto-switch|card-active|database-sync|manualswitch|protection-unavailable|switch-to-protect]


Usethealarmenablecommandtoallowthelistedredundancyalarmstobegeneratedwhen
thespecificerrorconditionsexist.

Syntax Description
autoswitch

Anautomaticprotectionswitchhastakenplace

cardactive

Aredundancyswitchhastakenplace

databasesync

DatabasesyncwithSwitchModuleislost

manualswitch

Arequestformanualswitchhastakenplace

protectionunavailable

Protectionisnotavailable

switchtoprotect

Aswitchtoprotecthasoccured

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1),
ComboAM(1187100L1)

Command ID
82830

6TANV57CLI-35A

2-2273

Total Access/NetVanta Carrier CLI Dictionary

alarm enable peer [mirror|version]


Usethiscommandtoenablealarmsduetoredundantpeerfaults.Theversionoptionalarms
whenthepeersoftwareversiondoesntmatchandthemirroroptionalarmswhenthestate/
provisoinginformationonthepeerisnotuptodate.Usethenoformofthiscommandto
disablealarms.

Syntax Description
mirror

Provisioningmirrorwithpeerisoutofsync

version

Peersoftwareorhardwareversionisincompatible

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),E1INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),DS1
FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87760

2-2274

6TANV57CLI-35A

Section 2, Commands - Redundancy Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),DS1PPPAM(1187803G2),E1
INTLPPPAM(1188803G2),CHDS3PPPAM(1187220G1),QuadGigELM(1187550E1),Quad
GigELM(1187550G2),QuadGigELM(1187551E1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),SM(1187020E1),SM(1187020L1),
SM2GE(1187020G1),SM2GE(1187020G2),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
80684

6TANV57CLI-35A

2-2275

Total Access/NetVanta Carrier CLI Dictionary

revertive
Therevertivecommandisusedtoprovisionrevertivebehaviorforredundancyoperation.If
revertivemodeisenabledSMAwillalwaysbeActiveunlessithasafault.IfSMAhada
faultandSMBiscurrentlyActive,oncethefailureiscorrectedinSMA,SMBrevertsto
StandbymodeandSMAreturnstotheActivestate.Usethenoformofthiscommandto
disablerevertivemode(nonrevertivemode).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46227

2-2276

6TANV57CLI-35A

Section 2, Commands - Redundancy Configuration Command Set

shutdown
Usetheshutdowncommandtodisabletheredundancymodefortheselectedcard.Usetheno
formofthiscommandtoenableredundancyfortheselectedcard.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable redundancy:
(config-redun 1/1)#shutdown
(config-redun 1/1)#
! To enable redundancy:
(config-redun 1/1)#no shutdown
(config-redun 1/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550E1),QuadGigELM(1187550G2)

Command ID
96609

6TANV57CLI-35A

2-2277

Total Access/NetVanta Carrier CLI Dictionary

wait-to-restore <15-65535>
Thewaittorestorecommandisusedtospecifytherevertivetimeoutinseconds.When
revertivemodeisenabled,SMBisactive,andSMAhasreturnedtoahealthystate,the
systemwillfailovertoSMAafterthespecifiedtimeouthaselapsed.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
QuadGigELM(1187550E1),QuadGigELM(1187550G2),QuadGigELM(1187551E1),SM
(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
58375

2-2278

6TANV57CLI-35A

Section 2, Commands - Relay Test Application Command Set

Relay Test Application Command Set


UsetheRelayTestApplicationcommandsettotestalarmrelaysforagivenshelf.
ChassisId>enable
ChassisId#application
ChassisId(app)#test alarm-relays <1-n>
ChassisId(app-tst-relay shelf x)#

ThefollowingisalistofcommandsavailableintheRelayTestApplicationCommandSet.
activateaudiblerelay[critical|major|minor]
activatevisualrelay[critical|major|minor]
exit

6TANV57CLI-35A

2-2279

Total Access/NetVanta Carrier CLI Dictionary

activate audible-relay [critical|major|minor]


Usetheactivateaudiblerelay[critical|major|minor]commandtoactivatetheaudiblerelay
alarmoutput.Usethenoformofthiscommandtodeactivatetheaudiblerelayalarmoutput.

Syntax Description
critical

Criticalaudible

major

Majoraudible

minor

Minoraudible

Usage Examples
Thefollowingisanexampleofhowtousetheactivateaudiblerelay[critical|major|minor]
command.
(app-tst-relay shelf 1)#activate audible-relay critical
(app-tst-relay shelf 1)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87784

2-2280

6TANV57CLI-35A

Section 2, Commands - Relay Test Application Command Set

activate visual-relay [critical|major|minor]


Usetheactivatevisualrelay[critical|major|minor]commandtoactivatethevisualrelay
alarmoutput.Usethenoformofthiscommandtodeactivatethevisualrelayalarmoutput.

Syntax Description
critical

Criticalvisual

major

Majorvisual

minor

Minorvisual

Usage Examples
Thefollowingisanexampleofhowtousetheactivatevisualrelay[critical|major|minor]
command.
(app-tst-relay shelf 1)#activate visual-relay critical
(app-tst-relay shelf 1)#

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87785

6TANV57CLI-35A

2-2281

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87704

2-2282

6TANV57CLI-35A

Section 2, Commands - RFVideo Interface Configuration Command Set

RFVideo Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface rf-video {}
ChassisId(config-rf-video x/x/x)#

ThefollowingisalistofcommandsavailableintheRFVideoInterfaceConfiguration
CommandSet.
exit
shutdown[maintenance|unassigned]
videoreturn

6TANV57CLI-35A

2-2283

Total Access/NetVanta Carrier CLI Dictionary

exit
Local Security Permissions
ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA361
2POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2POTS
2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
146403

2-2284

6TANV57CLI-35A

Section 2, Commands - RFVideo Interface Configuration Command Set

shutdown [maintenance|unassigned]
Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA361
2POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2POTS
2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
146357

6TANV57CLI-35A

2-2285

Total Access/NetVanta Carrier CLI Dictionary

video-return
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3342POTS4GERF(1287735G1),TA3612POTS1GERF(1187711G1),TA3622
POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA361
2POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2POTS
2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
144621

2-2286

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

SCA Configuration Command Set


UsetheSCAcommandsettoconfigureparametersassociatedwithSystemConfiguration
Archive.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#sca
ChassisId(config-sca)#

ThefollowingisalistofcommandsavailableintheSCAConfigurationCommandSet.
autosave
exit
maxinstances<17>
permitrestore[controller|modules]
permitrestorecontroller[sca|security|snmp]
permitrestorecontrollernetwork[general|interface]
permitrestoremodules[<shelf/slot>|emptyslots|inservice]
prefixWORD
retries<099>
schedule<HH:MM>
suffixWORD
updateonly

6TANV57CLI-35A

2-2287

Total Access/NetVanta Carrier CLI Dictionary

autosave
UsetheautosavecommandtoenabletheSCAautosavefeature.Usethenoformtodisable
SCAautosave.

Usage Examples
Thefollowingisanexampleofhowtousetheautosavecommand.
(config-sca)#autosave
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86905

2-2288

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80686

6TANV57CLI-35A

2-2289

Total Access/NetVanta Carrier CLI Dictionary

max-instances <1-7>
Usethemaxinstances<17>tosetthemaximumnumberofautosavefileinstances.Usethe
noformtosetthemaximumnumberofautosavefileinstancestothedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethemaxinstances<17>command.
(config-sca)#max-instances 7
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
45915

2-2290

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

permit-restore [controller|modules]
Usethepermitrestore[controller|modules]toenableSCArestores.Usethenoformtodiable
SCArestores.

Syntax Description
controller

Enablerestorationofcontrollerconfiguration

modules

Enablerestorationofmoduleconfiguration

Usage Examples
Thefollowingisanexampleofhowtousethepermitrestore[controller|modules]command.
(config-sca)#permit-restore modules empty-slots
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
45895

6TANV57CLI-35A

2-2291

Total Access/NetVanta Carrier CLI Dictionary

permit-restore controller [sca|security|snmp]


Usethepermitrestorecontroller[sca|security|snmp]toenablethetypeofprovisioning
itemstorestoretothecontrollerusingSCA.Usethenoformtodiablethetypeofprovi
sioningitemstoberestoredviaSCA.

Syntax Description
controller

Enablerestorationofcontrollerconfiguration

sca

EnablerestorecontrollerSCAprovisions

security

Enablerestorecontrollersecuritysystemprovisions

snmp

EnablerestorecontrollerSNMPprovisions

Usage Examples
Thefollowingisanexampleofhowtousethepermitrestorecontroller[sca|security|snmp]
command.
(config-sca)#permit-restore controller sca
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
45896

2-2292

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

permit-restore controller network [general|interface]


Usethepermitrestorecontrollernetwork[general|interface]toenabletherestorationof
networkprovisioningsettingstothecontrollerusingSCA.Usethenoformtodiablethetype
ofnetworkprovisioningitemstoberestoredviaSCA.

Syntax Description
general

Enablerestorecontrollernetworkgeneralprovisions

interface

Enablerestorecontrollernetworkinterfaceprovisions

Usage Examples
Thefollowingisanexampleofhowtousethepermitrestorecontrollernetwork
[general|interface]command.
config-sca)#permit-restore controller network general
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
45897

6TANV57CLI-35A

2-2293

Total Access/NetVanta Carrier CLI Dictionary

permit-restore modules [<shelf/slot>|empty-slots|in-service]


Usethepermitrestoremodules[<shelf/slot>|emptyslots|inservice]toselectthemodulesto
restoreusingSCA.UsethenoformtodiablethemodulestoberestoredviaSCA.

Syntax Description
modules

Enablerestorationofmoduleconfiguration

<shelf/slot>

Specifiedslot

emptyslots

Allemptyslots

inservice

Allinserviceslots

Usage Examples
Thefollowingisanexampleofhowtousethepermitrestoremodules[<shelf/slot>|empty
slots|inservice]command.
(config-sca)#permit-restore modules empty-slots
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
45903

2-2294

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

prefix WORD
UsetheprefixWORDcommandtoselectthefileprefixoftheSCAautosavefilename.Use
thenoformtosetthefileprefixtothedefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousetheprefixWORDcommand.
(config-sca)#prefix scafile
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66294

6TANV57CLI-35A

2-2295

Total Access/NetVanta Carrier CLI Dictionary

retries <0-99>
Usetheretries<099>commandtoselectthenumberofautosaveretries.Usethenoformto
setthenumberofretriestothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheretries<099>command.
(config-sca)#retries 99
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66286

2-2296

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

schedule <HH:MM>
Usetheschedule<HH:MM>tosetthehourandminuteofthescheduledSCAautosave.Use
thenoformtosetthehourandminutetothedefaultsettings.

Usage Examples
Thefollowingisanexampleofhowtousetheschedule<HH:MM>command.
(config-sca)#schedule 12:00
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66298

6TANV57CLI-35A

2-2297

Total Access/NetVanta Carrier CLI Dictionary

suffix WORD
UsethesuffixWORDcommandtoselectthefileextensionoftheSCAautosavefilename.
Usethenoformtosetthefileextensiontothedefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousethesuffixWORDcommand.
(config-sca)#suffix sca
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66296

2-2298

6TANV57CLI-35A

Section 2, Commands - SCA Configuration Command Set

update-only
UsetheupdateonlycommandtoenableautosaveupdatestotheSCAautosavefileonlyif
thereareprovisioningchanges.Usethenoformtodisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheupdateonlycommand.
(config-sca)#update-only
(config-sca)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66292

6TANV57CLI-35A

2-2299

Total Access/NetVanta Carrier CLI Dictionary

Security Configuration Command Set


UsetheSecurityConfigurationcommandsettoconfiguresystemsecurityparameters.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#security
ChassisId(config-sec)#

ThefollowingisalistofcommandsavailableintheSecurityConfigurationCommandSet.
accountexpiration
advisorywarning[message|tl1]
alarmenable[accountexpiration|lockout]
alarmenablelogin[console|failure|success]
alarmlevelloginconsole[alert|critical|information|major|minor]
alarmlevelloginfailure[alert|critical|information|major|minor]
alarmlevelloginsuccess[alert|critical|information|major|minor]
casesensitive
exit
lockoutduration<160>
lockoutfailures<215>
lockoutindefinite
multiplelogins
notification<015>
password[complexity|digit|expiration|lowercase|nodigitstartend|not
last|special|uppercase]
passwordlength<615>
snmpaccess
systemprivilege[admin|config|readonly|readwrite|test]
userlockout
usernameWORD

2-2300

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

account-expiration
Usetheaccountexpirationcommandtoenableaccountexpirationforallindividuallyenabled
accounts.Usethenoformofthiscommandtodisableaccountexpirationglobally.

Usage Examples
Thefollowingisanexampleofhowtousetheaccountexpirationcommand.
(config-sec)#account-expiration
(config-sec)#
(config-sec)#no account-expiration
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64584

6TANV57CLI-35A

2-2301

Total Access/NetVanta Carrier CLI Dictionary

advisory-warning [message|tl1]
Usetheadvisorywarning[message|tl1]toenablethesecurityadvisorybanner.Usetheno
formtodisablethesecurityadvisorybanner.

Syntax Description
message

Entertheadvisorywarningmessageformenu/CLI/TL1

tl1

EnableadvisorywarningmessageforTL1

Usage Examples
Thefollowingisanexampleofhowtousetheadvisorywarning[message|tl1]command.
(config-sec)#advisory-warning tl1
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83709

2-2302

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

alarm enable [account-expiration|lock-out]


Usethealarmenable[accountexpiration|lockout]commandtosendalarmswhenthe
accounthasexpiredortheuserhasbeenlockedout.Usethenofromtodisablethesealarms.

Syntax Description
accountexpiration

Useraccounthasexpired

lockout

Userhasbeenlockedoutduetofailedloginattempts

Usage Examples
Thefollowingisanexampleofhowtousethealarmenable[accountexpiration|lockout]
command.
(config-sec)#alarm enable account-expiration
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86788

6TANV57CLI-35A

2-2303

Total Access/NetVanta Carrier CLI Dictionary

alarm enable login [console|failure|success]


Usethealarmenableloginsuccesscommandtoenableanotificationwhenauserhassuccess
fullyloggedin.Usethealarmenableloginfailurecommandtoenableanotificationwhena
userhasfailedaloginattempt.Usethealarmenableloginconsolecommandtoenablea
notificationwhenauserhasloggedintothesystemconsoleport.Thenoformofeach
commanddisablesthealarm.

Syntax Description
console

Auserhasloggedintothesystemsconsoleport

failure

UserhasfailedinanattempttologintoaCLIsession

success

UserhassuccessfullyloggedintoaCLIsession

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablelogin[console|failure|success]
command.
(config-sec)#alarm enable login success
(config-sec)#no alarm enable login failure

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77424

2-2304

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

alarm level login console


[alert|critical|information|major|minor]
Usethealarmlevelloginconsolecommandtosettheseverityofthenotificationthatauser
hassuccessfullyloggedin.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelloginconsole[alert|critical|infor
mation|major|minor]command.
(config-sec)#alarm level login console critical
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46540

6TANV57CLI-35A

2-2305

Total Access/NetVanta Carrier CLI Dictionary

alarm level login failure [alert|critical|information|major|minor]


Usethealarmlevelloginfailurecommandtosettheseverityofthenotificationthatauserhas
failedaloginattempt.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelloginfailure[alert|critical|infor
mation|major|minor]command.
(config-sec)#alarm level login success minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77450

2-2306

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

alarm level login success


[alert|critical|information|major|minor]
Usethealarmlevelloginsuccesscommandtosettheseverityofthenotificationthatauser
hassuccessfullyloggedin.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelloginsuccess[alert|critical|infor
mation|major|minor]command.
(config-sec)#alarm level login success major

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77444

6TANV57CLI-35A

2-2307

Total Access/NetVanta Carrier CLI Dictionary

case-sensitive
Usethecasesensitivecommandtoenablecasesensitivepasswords.Usethenoformto
disablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousethecasesensitivecommand.
(config-sec)#case-sensitive
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83193

2-2308

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
80691

6TANV57CLI-35A

2-2309

Total Access/NetVanta Carrier CLI Dictionary

lock-out duration <1-60>


Usethelockoutduration<160>commandtosetthelengthoftimethatauserislockedoutof
theiraccount.Usethenoformtosetthedurationtothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethelockoutduration<160>command.
(config-sec)#lock-out duration 60
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64678

2-2310

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

lock-out failures <2-15>


Usethelockoutfailures<215>commandtosetthenumberofloginfailuresbeforeauseris
lockedoutoftheiraccount.Usethenoformtosetthenumberoffailurestothedefault
setting.

Usage Examples
Thefollowingisanexampleofhowtousethelockoutfailures<215>command.
(config-sec)#lock-out failures 15
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64680

6TANV57CLI-35A

2-2311

Total Access/NetVanta Carrier CLI Dictionary

lock-out indefinite
Usethelockoutindefinitecommandtolockouttheuseruntiltheadministratorunlocksthe
useraccount.Usethenoformdisablethissetting.

Usage Examples
Thefollowingisanexampleofhowtousethelockoutindefinitecommand.
(config-sec)#lock-out indefinite
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64681

2-2312

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

multiple-logins
Usethemultipleloginscommandtoallowmultipleloginsperusername.Usethenoformto
disablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousethemultipleloginscommand.
(config-sec)#multiple-logins
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83715

6TANV57CLI-35A

2-2313

Total Access/NetVanta Carrier CLI Dictionary

notification <0-15>
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64666

2-2314

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

password [complexity|digit|expiration|lowercase|no-digit-startend|not-last|special|uppercase]
Usethepasswordcommandstoconfigurepasswordcomplexitysettingsofthesystem.

Syntax Description
complexity

Enablepasswordcomplexity

digit

Enablepassworddigitcharacterrequired

expiration

Enablepasswordexpiration

lowercase

Enablepasswordlowercaserequired

nodigitstartend

Enablepasswordcannotstart/endwithdigit

notlast

Passwordcannotbethesameasthelast6passwords

special

Enablepasswordspecialcharacterrequired

uppercase

Enablepassworduppercaserequired

Usage Examples
Thefollowingisanexampleofhowtousethepassword
[complexity|digit|expiration|lowercase|nodigitstartend|notlast|special|uppercase]
command.
(config-sec)#password expiration
(config-sec)#
(config-sec)#password complexity
(config-sec)#
(config-sec)#password length 8
(config-sec)#
(config-sec)#password no-digit-start-end
(config-sec)#
(config-sec)#password special
(config-sec)#
(config-sec)#password lowercase
(config-sec)#
(config-sec)#password uppercase
(config-sec)#
(config-sec)#password not-last

6TANV57CLI-35A

2-2315

Total Access/NetVanta Carrier CLI Dictionary

(config-sec)#
(config-sec)#password digit
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
84613

2-2316

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

password length <6-15>


Usethepasswordlength<615>commandtosettheminimumpasswordlength.Usetheno
formtosetthelengthtothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethepasswordlength<615>command.
(config-sec)#password length 8
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83188

6TANV57CLI-35A

2-2317

Total Access/NetVanta Carrier CLI Dictionary

snmp-access
UsethesnmpaccesscommandtoallowSNMPsecurityaccountaccess.Usethenoformto
disablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousethesnmpaccesscommand.
(config-sec)#snmp-access
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
83314

2-2318

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

system-privilege [admin|config|read-only|read-write|test]
Usethesystemprivilegecommandtoactivatethecommandsforathegivenprivilegelevel.

Syntax Description
admin

Administratorprivileges

config

Configurationaccess

readonly

Readonlyaccess

readwrite

Readwriteaccess

test

Testprivileges

Usage Examples
Thefollowingisanexampleofhowtousethesystemprivilege[admin|config|read
only|readwrite|test]command.
(config-sec)#system-privilege admin
(config-sec-priv admin)#
(config-sec)#system-privilege read-only
(config-sec-priv read-only)#
(config-sec)#system-privilege read-write
(config-sec-priv read-write)#
(config-sec)#system-privilege test
(config-sec-priv test)#
(config-sec)#system-privilege config
(config-sec-priv config)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77737

6TANV57CLI-35A

2-2319

Total Access/NetVanta Carrier CLI Dictionary

user-lock-out
Usetheuserlockoutcommandtoenableuserlockoutonloginfailure.Usethenoformto
disablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheuserlockoutcommand.
(config-sec)#user-lock-out
(config-sec)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64682

2-2320

6TANV57CLI-35A

Section 2, Commands - Security Configuration Command Set

username WORD
UsetheusernameWORDcommandtoconfigurethesecurityusernamesforthesystem.

Usage Examples
ThefollowingisanexampleofhowtousetheusernameWORDcommand.
(config-sec)#username user
(config-sec-user user)#

Functional Notes
Thereisamaximunof16usernamesandeachusernamehasamaximunof16characters.
Unitshavethefollowingusersbydefault:
(usernamepasswordprivilegelevelstate)
ADMINPASSWORDadminenabled
READWRITEPASSWORDreadwritedisabled
READONLYPASSWORDreadonlydisabled
TESTPASSWORDtestdisabled

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77736

6TANV57CLI-35A

2-2321

Total Access/NetVanta Carrier CLI Dictionary

Shaper Configuration Command Set


UsetheShaperConfigurationCommandSettoconfiguretheshaper.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#shaper * <shelf/slot>
ChassisId(config-shaper name x/x)#

ThefollowingisalistofcommandsavailableintheShaperConfigurationCommandSet.
burst<0n>
exit
perinterfaceatm[<shelf/slot/port>|<shelf/slot/port.sub>]
perinterfaceefmgroup<shelf/slot/group>
perinterfaceefmport<shelf/slot/port>
perinterfaceethernet<shelf/slot/port>
perinterfacegigabitethernet<shelf/slot/port>
perinterfacegpon<remoteindex>channel<1>
perinterfacemuxponderhighspeed<shelf/slot/port>
perinterfacemuxpondermidspeed<shelf/slot/port>
perremotedevice<remoteindex>
queues<07>|LIST
rate<0n>
shutdown

2-2322

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

burst <0-n>
Usetheburst<0n>commandtoconfigurethenumberofconsecutivebytesallowedtoegress
attheinterfaceratewhennopacketshavebeensentforsometime.Usethenoformofthis
commandtoreturntothedefaultburst.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),NV8044(1172804G1)

Command ID
89253

6TANV57CLI-35A

2-2323

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Functional Notes
Theexitcommandhasnosubcommands.
Theexitcommandhasnodefaultvalues.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002POTS2GE
(1187602G2),TA3242POTS4GE(1287734G1),TA324E2POTS4GE(1287737G1),TA334
2POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GE
HPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA354E2POTS4GE(1287704G1),TA3612POTS1GERF(1187711G1),
TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF
(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,
TA3728POTS4DS1PWE2GESBU(1287722G1),TA372E8POTS4DS1PWE2GE
SBU(1287723G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3),NV814
(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
89269

2-2324

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

per interface atm [<shelf/slot/port>|<shelf/slot/port.sub>]


Usetheperinterfaceatm<shelf/slot/port>commandtoapplytheshapertoalltrafficona
particularsetofqueuesonaparticularATMinterface.Usethenoformofthiscommandto
removetheshaperfromthespecifiedinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),ADSLAMwith
VDSLSplitterComp(1187102G1)

Command ID
89259

6TANV57CLI-35A

2-2325

Total Access/NetVanta Carrier CLI Dictionary

per interface efm-group <shelf/slot/group>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
137433

2-2326

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

per interface efm-port <shelf/slot/port>


Usetheperinterfaceefmport<shelf/slot/port>commandtoapplytheshapertoalltrafficona
particularsetofqueuesonaparticularefmportinterface.Usethenoformofthiscommandto
removetheshaperfromthespecifiedinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1)

Command ID
89256

6TANV57CLI-35A

2-2327

Total Access/NetVanta Carrier CLI Dictionary

per interface ethernet <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
137436

2-2328

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

per interface gigabit-ethernet <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ActiveEth24PortAM(1187560F1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187025G2),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
116905

6TANV57CLI-35A

2-2329

Total Access/NetVanta Carrier CLI Dictionary

per interface gpon <remote-index> channel <1>


Examples:Shaperbob2ont@shelf/slot/ponRate*Burst*Perinterfacegponont/slot/
pon@shelf/slot/ponchannelallNoshut

Syntax Description
dynamic
<remoteindex>

Indexforaremotedevice(RD)orinterface.Theprimary
formsare:&lt;RDID/RDslot/RD
port&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;RD
ID&gt;@&lt;shelf/slot/intf&gt;.&lt;intftype&gt;&lt;shelf/
slot/port&gt;@node&lt;nodenum&gt;Examplesare
1@1/5/12.gigabitethernetand4/0/1@1/3/2.gpon
and1/5/17@node4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
TA3002POTS2GE(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GE
RF(1287735G1),TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA
(1187701G3),TA3522POTS2GE(1187702G1),TA352H2POTS2GEHPNA
(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS2GERF
(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2POTS2GE
RFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1PWE2GE
SBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE(1287702G1),
TA3612POTS1GERF(1287711G1),TA3622POTS2GERF(1287712G1),TA362R2
POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNARF(1287712G3)

Command ID
144963

2-2330

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

per interface muxponder-highspeed <shelf/slot/port>


Functional Notes
Usetheperinterfacemuxponderhighspeed<shelf/slot/port>commandtoapplytheshaperto
alltrafficonaparticularinterface.?Usethenoformofthiscommandtoremovetheshaper
fromtheinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135993

6TANV57CLI-35A

2-2331

Total Access/NetVanta Carrier CLI Dictionary

per interface muxponder-midspeed <shelf/slot/port>


Functional Notes
Usetheperinterfacemuxpondermidspeed<shelf/slot/port>commandtoapplytheshaperto
alltrafficonaparticularinterface.?Usethenoformofthiscommandtoremovetheshaper
fromtheinterfacetraffic.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
135991

2-2332

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

per remote-device <remote-index>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ActiveEth24PortAM(1187560F1),TA3002POTS2GE(1187602G2),TA3242POTS4
GE(1287734G1),TA3342POTS4GERF(1287735G1),TA3512POTS1GE(1187701G1),
TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE(1187702G1),TA352H2
POTS2GEHPNA(1287702G3),TA3612POTS1GERF(1187711G1),TA3622POTS
2GERF(1187712G1),TA362S2POTS1GE1FESWRDRF(1187712G2),TA362R2
POTS2GERFoG(1187715G1),TA3652POTS1GERFRFoG,TA3728POTS4DS1
PWE2GESBU(1287722G1),TA3512POTS1GE(1287701G1),TA3522POTS2GE
(1287702G1),TA3612POTS1GERF(1287711G1),TA3622POTS2GERF
(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H2POTS2GEHPNA
RF(1287712G3)

Command ID
134306

6TANV57CLI-35A

2-2333

Total Access/NetVanta Carrier CLI Dictionary

queues <0-7>|LIST
UsethequeueLISTcommandtoconfigurethesetofqueuesontheinterfacetoshape.Usethe
noformofthiscommandtoreturntothedefaultqueueset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),TA3002POTS2GE(1187602G2),
TA3242POTS4GE(1287734G1),TA3342POTS4GERF(1287735G1),TA3512POTS
1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522POTS2GE
(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA3612POTS1GERF
(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FESWRD
RF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GERF
RFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA3512POTS1GE
(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3)

Command ID
89271

2-2334

6TANV57CLI-35A

Section 2, Commands - Shaper Configuration Command Set

rate <0-n>
Usetherate<0n>commandtoconfiguretheshapedrate.Trafficegressesatarateuptothe
valuespecified.Usethenoformofthiscommandtoreturntothedefaultrate.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002POTS2GE
(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA3512POTS1GE
(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
89252

6TANV57CLI-35A

2-2335

Total Access/NetVanta Carrier CLI Dictionary

shutdown
Usetheshutdowncommandtoadministrativelydisabletheshaper.Usethenoformofthis
commandtoenabletheshaper.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the shaper:
(config-shaper name 1/1)#shutdown
(config-shaper name 1/1)#
! To enable the shaper:
(config-shaper name 1/1)#no shutdown
(config-shaper name 1/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ADSL2AM(1187101E1),ADSL2INTLAM(1188101E1),ComboAM(1187100L1),ComboAM
(1187100L2),GPONAM(1187501G1),VDSL2Combo24PAM(1187120L1),VDSL2AM
(1187121L1),ADSLAMwithVDSLSplitterComp(1187102G1),ActiveEth24PortAM
(1187560F1),10GEthernetMuxponder(1174101F1),SM2GE(1187020G1),SM2GE
(1187020G2),SM10GE(1187025G1),SM10GE(1187025G2),TA3002POTS2GE
(1187602G2),TA3242POTS4GE(1287734G1),TA3342POTS4GERF(1287735G1),
TA3512POTS1GE(1187701G1),TA351H2POTS1GEHPNA(1187701G3),TA3522
POTS2GE(1187702G1),TA352H2POTS2GEHPNA(1287702G3),TA3612POTS1
GERF(1187711G1),TA3622POTS2GERF(1187712G1),TA362S2POTS1GE1FE
SWRDRF(1187712G2),TA362R2POTS2GERFoG(1187715G1),TA3652POTS1GE
RFRFoG,TA3728POTS4DS1PWE2GESBU(1287722G1),TA3512POTS1GE
(1287701G1),TA3522POTS2GE(1287702G1),TA3612POTS1GERF(1287711G1),
TA3622POTS2GERF(1287712G1),TA362R2POTS2GERFoG(1287715G1),TA362H
2POTS2GEHPNARF(1287712G3),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
89261

2-2336

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

SHDSL Interface Configuration Command Set


UsetheSHDSLInterfaceConfigurationCommandSettoconfigureaSHDSLinterfaceas
definedbyITUG.991.2.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface shdsl <shelf/slot/port>
ChassisId(config-shdsl x/x/x)#

ThefollowingisalistofcommandsavailableintheSHDSLInterfaceConfiguration
CommandSet.
alarmenableshutdownmaintenance
annex[a|aefm|aorb|aorbefm|b|befm|efm]
constellationcrossoverrate<1260>
descriptionLINE
diagnosticslooplocator
diagnosticssplicedetectdistancetype[feet|meters]
exit
linerateadaptive[g9912|maxrate|t1417]
linerateadaptive<389><1020>[currentcondition|worstcasecondition]
linerateadaptiveg9912[nl|us]
lineratefixed<389>
powerbackoff[<031>|auto]
shutdown[maintenance|unassigned]
thresholdscvc15minute<02147483647>
thresholdscvc24hour<02147483647>
thresholdses15minute<0900>
thresholdses24hour<086400>
thresholdsloopattenuation<0127>
thresholdslosws15minute<0900>
thresholdslosws24hour<086400>
thresholdsses15minute<0900>
thresholdsses24hour<086400>
thresholdssnrmargin<015>
thresholdsuas15minute<0900>
thresholdsuas24hour<086400>

6TANV57CLI-35A

2-2337

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
111842

2-2338

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

annex [a|a-efm|a-or-b|a-or-b-efm|b|b-efm|efm]
Usetheannex[a|aefm|aorb|aorbefm|b|befm|efm]commandtospecifytheG.991.2
annexfortheSHDSLport.

Syntax Description
a

UseannexA(NorthAmerica)

aefm

UseannexAandIEEE802.3ahhandshakeparameters

aorb

UseeitherannexAorBdependingonconnectedterminating
unit

aorbefm

UseeitherannexAorBandIEEE802.3ahhandshakeparameters

UseannexB(outsideofNorthAmerica)

befm

UseannexBandIEEE802.3ahhandshakeparameters

efm

EFMhandshake

Usage Examples
Thefollowingisanexampleofhowtousetheannex[a|aefm|aorb|aorbefm|b|b
efm|efm]command.
(config-shdsl 1/0/1)#annex a
(config-shdsl 1/0/0)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42410

6TANV57CLI-35A

2-2339

Total Access/NetVanta Carrier CLI Dictionary

constellation crossover-rate <12-60>


Usetheconstellationcrossoverratecommandtosettheratetotheparameter.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
42433

2-2340

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedSHDSLinterface.Usetheno
formofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-shdsl 1/0/1)#description SHDSL Port 1
(config-shdsl 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
78731

6TANV57CLI-35A

2-2341

Total Access/NetVanta Carrier CLI Dictionary

diagnostics loop-locator
Functional Notes
Thiscommandhasnohelpforareason.Itshouldbeavailabe,buthiddenfromanormaluser.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1)

Command ID
146704

2-2342

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

diagnostics splice-detect distance-type [feet|meters]


Usethediagnosticssplicedetectdistancetype[feet|meters]commandtospecifytheunitof
measureusedinthedisplayofsplicedetectionstatistics.

Syntax Description
feet

Changedistancetypetofeet

meters

Changedistancetypetometers

Usage Examples
Thefollowingisanexampleofhowtousethediagnosticssplicedetectdistancetype
[feet|meters]command.
(config-shdsl 1/0/1)#diagnostics splice-detect distance-type feet
(config-shdsl 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42435

6TANV57CLI-35A

2-2343

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
78806

2-2344

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

linerate adaptive [g991-2|max-rate|t1-417]


Usethelinerateadaptive[g9912|maxrate|t1417]commandtospecifythelinerateinDS0s
andtrainingprocedurefortheSHDSLport.Bestefforttrainingmeasuresthelinelength,then
trainswithinarangeofratesbasedoncurrentlineconditions.Usethenoformofthis
commandtosetthelinerateparameterstofactorydefaults.

Syntax Description
g9912

PerITUG991.2deploymentguidelines

maxrate

NotrecommendedperADTRANdeploymentguidelines

t1417

PerT1.417deploymentguidelines

Usage Examples
Thefollowingisanexampleofhowtousethelinerateadaptive[g9912|maxrate|t1417]
command.
(config-shdsl 1/0/1)#linerate adaptive g991-2
(config-shdsl 1/0/1)#

Functional Notes
Usetheg9912optiontosettheupperratetonotexceedthe49selfNEXTdisturberratefrom
G991.2.
Usethemaxrateoptiontosetnoupperratelimit.Notethatthemaxratecanexceedtherates
recommendedbyAdtranandtheG991.2specification.Maxrateisrecommendedforline
simulator,lab,orverylownoiseenvironments.
Usethet1417optiontosettheupperratetonotexceedT1.417.NotethatT1.417canexceed
theratesrecommendedbyAdtranandtheG991.2specification.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42422

6TANV57CLI-35A

2-2345

Total Access/NetVanta Carrier CLI Dictionary

linerate adaptive <3-89> <-10-20> [currentcondition|worstcase-condition]


Usethelinerateadaptive<389><1020>[currentcondition|worstcasecondition]commandto
specifythelinerateinDS0sandtrainingprocedurefortheSHDSLport.Thetwomethodsof
trainingarefixedandadaptive.Fixedmodeisconstrainedbythemin/maxlineratesspecified.
Adaptivemode(lineprobing)isconstrainedbythemin/maxratesspecified,thecondition
selectedforprobing,andthetargetmargin.Usethenoformofthiscommandtosettheline
rateparameterstothefactorydefaults.

Syntax Description
<389>

Rangeofallowedtrainingrates(nx64k)

currentcondition

NotrecommendedperITUT_G991.2Section6.3.6

worstcasecondition

Useworstcasenoisemodels

Usage Examples
Thefollowingisanexampleofhowtousethelinerateadaptive<389><1020>[current
condition|worstcasecondition]command.
(config-shdsl 1/0/1)#linerate adaptive 24-44 -10 worstcase
(config-shdsl 1/0/1)#

Functional Notes
Usethe<389>inputtosetthelinerate.Thevalidrangeforthelinerateis389DS0s.Usethe
<1020>inputtosetthetargetmargin.Thevalidrangeforthetargetmarginis1020.
Lineprobingisdisabledifthetrainingmodeissettofixed.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42425

2-2346

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

linerate adaptive g991-2 [nl|us]


Usethelinerateadaptiveg9912commandtosettheupperratetonotexceedthe49selfNEXT
disturberratefromG991.2.

Syntax Description
g9912

PerITUG991.2deploymentguidelines

nl

PerNetherlandsAmendmenttoITUG991.2deploymentguide
lines

us

PerITUG991.2AnnexA(US)deploymentguidelines

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
118958

6TANV57CLI-35A

2-2347

Total Access/NetVanta Carrier CLI Dictionary

linerate fixed <3-89>


Usethelineratefixed<389>commandtospecifythelinerateinDS0sandtrainingprocedure
fortheSHDSLport.Thetwomethodsoftrainingarefixedandadaptive.Fixedmodeis
constrainedbythemin/maxlineratesspecified.Adaptivemode(lineprobing)isconstrained
bythemin/maxratesspecified,theconditionselectedforprobing,andthetargetmargin.Use
thenoformofthiscommandtosetthelinerateparameterstothefactorydefaults.

Usage Examples
Thefollowingisanexampleofhowtousethelineratefixed<389>command.
(config-shdsl 1)#linerate fixed 88
(config-shdsl 1)#

Functional Notes
Usethe<389>inputtosetthelinerate.Thevalidrangeforthelinerateis389DS0s.
Lineprobingisdisabledifthetrainingmodeissettofixed.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42420

2-2348

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

power-back-off [<0-31>|auto]
Usethepowerbackoff[<031>|auto]commandtospecifythepowerbackoff(PBO)setting
fortheselectedSHDSLport.TheSHDSLportthenrequeststhefarendtransmittertoreduce
thetransmitpowerbytheamountspecified.UsethenoformofthiscommandtodisablePBO
fortheselectedSHDSLport.Also,inputadBvalueofzerotodisablePBO.

Syntax Description
<031>

ReducetransmitpowerbyspecifieddBvalue

auto

Automaticallyreducetransmitpowerbasedonlineconditions

Usage Examples
Thefollowingisanexampleofhowtousethepowerbackoff[<031>|auto]command.
(config-shdsl 1/0/1)#power-back-off auto
(config-shdsl 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42404

6TANV57CLI-35A

2-2349

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-shdsl 1/0/1)#shutdown
(config-shdsl 1/0/1)#
! To disable the interface:
(config-shdsl 1/0/1)#shutdown unassigned
(config-shdsl 1/0/1)#
! To enable the interface:
(config-shdsl 1/0/1)#no shutdown
(config-shdsl 1/0/1)#
! To enable the interface but inhibit alarms:
(config-shdsl 1/0/1)#shutdown maintenance
(config-shdsl 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

2-2350

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

Command ID
78687

6TANV57CLI-35A

2-2351

Total Access/NetVanta Carrier CLI Dictionary

thresholds cvc 15-minute <0-2147483647>


Usethresholdscvc15minute<02147483647>commandtoconfigurethe15minuteCode
ViolationCountperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvc15minute<02147483647>
command.
(config-shdsl 1/0/1)#thresholds cvc 15-minute 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis02147483647.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42480

2-2352

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds cvc 24-hour <0-2147483647>


Usethresholdscvc24hour<02147483647>commandtoconfigurethe24hourCodeViolation
Countperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvc24hour<02147483647>
command.
(config-shdsl 1/0/1)#thresholds cvc 24-hour 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis02147483647.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42482

6TANV57CLI-35A

2-2353

Total Access/NetVanta Carrier CLI Dictionary

thresholds es 15-minute <0-900>


Usethethresholdses15minute<0900>commandtoconfigurethe15minuteErrored
Secondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses15minute<0900>command.
(config-shdsl 1/0/1)#thresholds es 15-minute 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis0900seconds.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42450

2-2354

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds es 24-hour <0-86400>


Usethethresholdses24hour<086400>commandtoconfigurethe24hourErroredSeconds
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdses24hour<086400>command.
(config-shdsl 1/0/1)#thresholds es 24-hour 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis086400seconds.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42452

6TANV57CLI-35A

2-2355

Total Access/NetVanta Carrier CLI Dictionary

thresholds loop-attenuation <0-127>


Usethethresholdsloopattenuation<0127>commandtoconfiguretheloopattenuation
threshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsloopattenuation<0127>command.
(config-shdsl 1/0/1)#thresholds loop-attenuation 125
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis0127dB.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42445

2-2356

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds losws 15-minute <0-900>


Usethresholdslosws15minute<0900>commandtoconfigurethe15minuteLossofSync
WordSecondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslosws15minute<0900>command.
(config-shdsl 1/0/1)#thresholds losws 15-minute 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis0900seconds.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42490

6TANV57CLI-35A

2-2357

Total Access/NetVanta Carrier CLI Dictionary

thresholds losws 24-hour <0-86400>


Usethresholdslosws24hour<086400>commandtoconfigurethe24hourLossofSyncWord
Secondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslosws24hour<086400>command.
(config-shdsl 1/0/1)#thresholds losws 24-hour 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis086400seconds.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42492

2-2358

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds ses 15-minute <0-900>


Usethresholdsses15minute<0900>commandtoconfigurethe15minuteSeverelyErrored
Secondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses15minute<0900>command.
(config-shdsl 1/0/1)#thresholds ses 15-minute 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis0900seconds.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42460

6TANV57CLI-35A

2-2359

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses 24-hour <0-86400>


Usethresholdsses24hour<086400>commandtoconfigurethe24hourSeverelyErrored
Secondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsses24hour<086400>command.
(config-shdsl 1/0/1)#thresholds ses 24-hour 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis086400seconds.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42462

2-2360

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds snr-margin <0-15>


Usethethresholdssnrmargin<015>commandtoconfiguretheSNRmarginthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssnrmargin<015>command.
(config-shdsl 1/0/1)#thresholds snr-margin 10
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis015dB.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42441

6TANV57CLI-35A

2-2361

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas 15-minute <0-900>


Usethresholdsuas15minute<0900>commandtoconfigurethe15minuteUnavailable
Secondsperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas15minute<0900>command.
(config-shdsl 1/0/1)#thresholds uas 15-minute 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis0900seconds.Setthethresholdto0todisablethealarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42470

2-2362

6TANV57CLI-35A

Section 2, Commands - SHDSL Interface Configuration Command Set

thresholds uas 24-hour <0-86400>


Usethresholdsuas24hour<086400>commandtoconfigurethe24hourUnavailableSeconds
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuas24hour<086400>command.
(config-shdsl 1/0/1)#thresholds uas 24 hour 20
(config-shdsl 1/0/1)#

Functional Notes
Thevalidrangeforthethresholdis086400seconds.Setthethresholdto0todisablethe
alarm.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMSHDSLAM(1187180L1),EFMSHDSLINTLAM(1188180E1),NV832(1200718E1),NV
832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838
EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7)

Command ID
42472

6TANV57CLI-35A

2-2363

Total Access/NetVanta Carrier CLI Dictionary

SIP Trunk Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#voice sip-trunk <Txx>
ChassisId(config-sip-trunk name)#

ThefollowingisalistofcommandsavailableintheSIPTrunkConfigurationCommandSet.
dialstringsource[requesturi|to]
domainWORD
exit
sipauthenticate
sipgrammaralertinfourlWORD
sipgrammarfromhost[domain|local|sipproxy]
sipgrammarrequesturihost[domain|sipoutboundproxy|sipproxy]
sipgrammarrequesturihostresolve
sipgrammarrequire100rel
sipgrammarsupported100rel
sipgrammartohost[domain|sipproxy]
sipgrammaruseragent[LINE|default|none]
sipkeepaliveinterval<303600>
sipkeepalivemethod[info|none|options]
sipoutboundproxyprimary[A.B.C.D|WORD]
sipoutboundproxyprimary[A.B.C.D|WORD]udp
sipoutboundproxyprimary[A.B.C.D|WORD]udp<065535>
sipoutboundproxysecondary[A.B.C.D|WORD]
sipoutboundproxysecondary[A.B.C.D|WORD]udp
sipoutboundproxysecondary[A.B.C.D|WORD]udp<065535>
sipproxyprimary[A.B.C.D|WORD]
sipproxyprimary[A.B.C.D|WORD]udp<065535>
sipproxysecondary[A.B.C.D|WORD]
sipproxysecondary[A.B.C.D|WORD]udp<065535>
sipregistrarexpiretime<302147483647>
sipregistrarmaxconcurrentreg<132>
sipregistrarprimary[A.B.C.D|WORD]
sipregistrarprimary[A.B.C.D|WORD]udp<065535>
sipregistrarrequireexpires
sipregistrarsecondary[A.B.C.D|WORD]
sipregistrarsecondary[A.B.C.D|WORD]udp
sipregistrarsecondary[A.B.C.D|WORD]udp<065535>

2-2364

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

siptimerinvitefailurerollover<132>
siptimerregistrationfailureretry<10604800>

6TANV57CLI-35A

2-2365

Total Access/NetVanta Carrier CLI Dictionary

dial-string source [request-uri|to]


Syntax Description
requesturi

UsetheRequestURIuserfieldasthedialstring

to

UsetheToheaderuserfieldasthedialstring

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96256

2-2366

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

domain WORD
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96234

6TANV57CLI-35A

2-2367

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
103113

2-2368

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip authenticate
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
95972

6TANV57CLI-35A

2-2369

Total Access/NetVanta Carrier CLI Dictionary

sip grammar alert-info url WORD


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96056

2-2370

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip grammar from host [domain|local|sip-proxy]


Syntax Description
domain

UsetrunkdomainsettingforformattingFromheader

local

UsealocalIPforformattingFromheader

sipproxy

UsetrunksipproxysettingforformattingFromheader

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96013

6TANV57CLI-35A

2-2371

Total Access/NetVanta Carrier CLI Dictionary

sip grammar request-uri host [domain|sip-outbound-proxy|sipproxy]


Syntax Description
domain

UsethetrunkdomainsettingforformattingtheRequestURI

sipoutboundproxy

Usethetrunkoutboundproxysettingforformattingthe
RequestURI

sipproxy

UsethetrunkSIPproxysettingforformattingtheRequestURI

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96004

2-2372

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip grammar request-uri host-resolve


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96001

6TANV57CLI-35A

2-2373

Total Access/NetVanta Carrier CLI Dictionary

sip grammar require 100rel


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96093

2-2374

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip grammar supported 100rel


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96061

6TANV57CLI-35A

2-2375

Total Access/NetVanta Carrier CLI Dictionary

sip grammar to host [domain|sip-proxy]


Syntax Description
domain

UsetrunkdomainsettingforformattingToheader

sipproxy

UsetrunksipproxysettingforformattingToheader

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96047

2-2376

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip grammar user-agent [LINE|default|none]


Syntax Description
LINE

ReplaceUserAgentvalue(max128characters)

default

SetUserAgentvaluetothedefaultvalueforthisproduct

none

DisableUserAgentheaderfield

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96096

6TANV57CLI-35A

2-2377

Total Access/NetVanta Carrier CLI Dictionary

sip keep-alive interval <30-3600>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96603

2-2378

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip keep-alive method [info|none|options]


Syntax Description
info

UsetheINFOmethod

none

NoKeepAlive

options

UsetheOPTIONSmethod

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96599

6TANV57CLI-35A

2-2379

Total Access/NetVanta Carrier CLI Dictionary

sip outbound-proxy primary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96205

2-2380

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip outbound-proxy primary [A.B.C.D|WORD] udp


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96206

6TANV57CLI-35A

2-2381

Total Access/NetVanta Carrier CLI Dictionary

sip outbound-proxy primary [A.B.C.D|WORD] udp <0-65535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96207

2-2382

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip outbound-proxy secondary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96209

6TANV57CLI-35A

2-2383

Total Access/NetVanta Carrier CLI Dictionary

sip outbound-proxy secondary [A.B.C.D|WORD] udp


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96210

2-2384

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip outbound-proxy secondary [A.B.C.D|WORD] udp <065535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96211

6TANV57CLI-35A

2-2385

Total Access/NetVanta Carrier CLI Dictionary

sip proxy primary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96190

2-2386

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip proxy primary [A.B.C.D|WORD] udp <0-65535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96192

6TANV57CLI-35A

2-2387

Total Access/NetVanta Carrier CLI Dictionary

sip proxy secondary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96194

2-2388

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip proxy secondary [A.B.C.D|WORD] udp <0-65535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96196

6TANV57CLI-35A

2-2389

Total Access/NetVanta Carrier CLI Dictionary

sip registrar expire-time <30-2147483647>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96169

2-2390

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip registrar max-concurrent-reg <1-32>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96183

6TANV57CLI-35A

2-2391

Total Access/NetVanta Carrier CLI Dictionary

sip registrar primary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96220

2-2392

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip registrar primary [A.B.C.D|WORD] udp <0-65535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96222

6TANV57CLI-35A

2-2393

Total Access/NetVanta Carrier CLI Dictionary

sip registrar require-expires


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96186

2-2394

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip registrar secondary [A.B.C.D|WORD]


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96224

6TANV57CLI-35A

2-2395

Total Access/NetVanta Carrier CLI Dictionary

sip registrar secondary [A.B.C.D|WORD] udp


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96225

2-2396

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip registrar secondary [A.B.C.D|WORD] udp <0-65535>


Syntax Description
A.B.C.D

IPaddress

WORD

HostName

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96226

6TANV57CLI-35A

2-2397

Total Access/NetVanta Carrier CLI Dictionary

sip timer invite-failure rollover <1-32>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
131484

2-2398

6TANV57CLI-35A

Section 2, Commands - SIP Trunk Configuration Command Set

sip timer registration-failure retry <10-604800>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
131486

6TANV57CLI-35A

2-2399

Total Access/NetVanta Carrier CLI Dictionary

System Alarm Configuration Command Set


UsetheSystemAlarmConfigurationcommandsettoconfiguresystemalarms.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#system-alarm <shelf>
ChassisId(config-sys-alarm shelf x)#

ThefollowingisalistofcommandsavailableintheSystemAlarmConfigurationCommand
Set.
alarmaidexternalinput<1n><1n>
alarmaidpowerfailac<1n>
alarmaidpowerfaildca<1n>
alarmaidpowerfaildcb<1n>
alarmconditioncodeexternalinput<1n>WORD
alarmconditioncodepowerfailacWORD
alarmconditioncodepowerfaildcaWORD
alarmconditioncodepowerfaildcbWORD
alarmdescriptionexternalinput<1n>WORD
alarmdescriptionpowerfailacWORD
alarmenable[bandwidthunavailable|downstreamnode|duplicatenode
number|duplicatescmip|internalsystemstag|nodenumber|powerlimit|ring
generator]
alarmenableexternalinput<1n>
alarmenablemodule[commfailure|removed|restart]
alarmenablepowerfailac
alarmenablepowerfaildc[a|b]
alarmenableshelf<24>[linkdown|linkremoved]
alarmenabletestaudiblerelay[critical|major|minor]
alarmenabletestvisualrelay[critical|major|minor]
alarmlevelexternalinput<1n>[alert|critical|information|major|minor]
alarmlevelmoduleremoved[critical|major|minor]
alarmlevelpowerfailac[alert|critical|information|major|minor]
alarmlevelpowerfaildca[alert|critical|information|major|minor]
alarmlevelpowerfaildcb[alert|critical|information|major|minor]
alarmlevelswitchremoved[critical|major|minor]
chronology[ascending|descending]
exit

2-2400

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm aid external-input <1-n> <1-n>


Usethealarmaidexternalinput<1n><1n>tosettheAIDforthespecifiedexternalalarm.
UsethenoformtosettheAIDoftheselectedalarmtoitsdefaultsetting.

Syntax Description
<1n>

Indexofexternalalarminput

Usage Examples
Thefollowingisanexampleofhowtousethealarmaidexternalinput<1n><1n>command.
(config-sys-alarm shelf 1)#alarm aid external-input 1 49
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87273

6TANV57CLI-35A

2-2401

Total Access/NetVanta Carrier CLI Dictionary

alarm aid power-fail ac <1-n>


Usethealarmaidpowerfailac<1n>tosettheAIDfortheacpowerfailalarm.Usetheno
formtosettheAIDoftheselectedinputtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethealarmaidpowerfailac<1n>command.
(config-sys-alarm shelf 1)#alarm aid power-fail ac 30
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87265

2-2402

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm aid power-fail dc a <1-n>


Usethealarmaidpowerfaildca<1n>tosettheAIDfortheDCApowerfailalarm.Usethe
noformtosettheAIDoftheselectedinputtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethealarmaidpowerfaildca<1n>command.
(config-sys-alarm shelf 1)#alarm aid power-fail dc a 31
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87268

6TANV57CLI-35A

2-2403

Total Access/NetVanta Carrier CLI Dictionary

alarm aid power-fail dc b <1-n>


Usethealarmaidpowerfaildcb<1n>tosettheAIDfortheDCApowerfailalarm.Usethe
noformtosettheAIDoftheselectedinputtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethealarmaidpowerfaildcb<1n>command.
(config-sys-alarm shelf 1)#alarm aid power-fail dc b 32
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87270

2-2404

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm condition-code external-input <1-n> WORD


Usethealarmconditioncodeexternalinput<1n>WORDtosettheconditioncodeforthe
specifiedexternalalarminput.Usethenoformtosettheconditioncodeoftheselectedinput
toitsdefaultsetting.

Syntax Description
<1n>

Indexofexternalalarminput

Usage Examples
Thefollowingisanexampleofhowtousethealarmconditioncodeexternalinput<1n>
WORDcommand.
(config-sys-alarm shelf 1)#alarm condition-code external-input 1 EXT1
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87262

6TANV57CLI-35A

2-2405

Total Access/NetVanta Carrier CLI Dictionary

alarm condition-code power-fail ac WORD


UsethealarmconditioncodepowerfailacWORDtosettheconditioncodeforthespecified
acpowerfailalarm.Usethenoformtosettheconditioncodeoftheselectedalarmtoits
defaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousethealarmconditioncodepowerfailacWORD
command.
(config-sys-alarm shelf 1)#alarm condition-code power-fail ac ACPFAIL
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87250

2-2406

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm condition-code power-fail dc a WORD


UsethealarmconditioncodepowerfaildcaWORDtosettheconditioncodefortheDCA
powerfailalarm.Usethenoformtosettheconditioncodeoftheselectedalarmtoitsdefault
setting.

Usage Examples
ThefollowingisanexampleofhowtousethealarmconditioncodepowerfaildcaWORD
command.
(config-sys-alarm shelf 1)#alarm condition-code power-fail dc a DCAPFAIL
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87258

6TANV57CLI-35A

2-2407

Total Access/NetVanta Carrier CLI Dictionary

alarm condition-code power-fail dc b WORD


UsethealarmconditioncodepowerfaildcbWORDtosettheconditioncodefortheDCB
powerfailalarm.Usethenoformtosettheconditioncodeoftheselectedalarmtoitsdefault
setting.

Usage Examples
ThefollowingisanexampleofhowtousethealarmconditioncodepowerfaildcbWORD
command.
(config-sys-alarm shelf 1)#alarm condition-code power-fail dc a DCBPFAIL
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87259

2-2408

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm description external-input <1-n> WORD


Usethealarmdescriptionexternalinput<1n>WORDtosetthedescriptionforthespecified
externalalarm.Usethenoformtosetthealarmdescriptionoftheselectedalarmtoits
defaultsetting.

Syntax Description
<1n>

Indexofexternalalarminput

Usage Examples
Thefollowingisanexampleofhowtousethealarmdescriptionexternalinput<1n>WORD
command.
(config-sys-alarm shelf 1)#alarm description external-input 1 "External
Input 1"
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87276

6TANV57CLI-35A

2-2409

Total Access/NetVanta Carrier CLI Dictionary

alarm description power-fail ac WORD


UsethealarmdescriptionpowerfailacWORDtosetthedescriptionfortheACpowerfail
alarm.UsethenoformtosetthealarmdescriptionoftheACpowerfailalarmtoitsdefault
setting.

Usage Examples
ThefollowingisanexampleofhowtousethealarmdescriptionpowerfailacWORD
command.
(config-sys-alarm shelf 1)#alarm description power-fail ac "Power Fail
Alarm"
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
87278

2-2410

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm enable [bandwidth-unavailable|downstreamnode|duplicate-node-number|duplicate-scm-ip|internalsystem-s-tag|node-number|power-limit|ring-generator]


UsethealarmenablecommandtoallowthelistedSystemAlarmstobegeneratedwhenthe
conditionsaremet.Mostofthesealarmsaregeneratedonlyinamultinodeconfiguration.

Syntax Description
bandwidthunavailable

Insufficentbandwidthresourcestoallowconnection

downstreamnode

Downstreamnodeinalarm

duplicatenodenumber

Duplicatenodenumberintree

duplicatescmip

DuplicateSCMIPaddress

internalsystemstag

Faultonstagusedforinternalsystemcommunication

nodenumber

Nodenumberisnotconfigured

powerlimit

Shelfpowerlimit

ringgenerator

Ringgenerator

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
66199

6TANV57CLI-35A

2-2411

Total Access/NetVanta Carrier CLI Dictionary

alarm enable external-input <1-n>


Usethealarmenableexternalinput<1n>toenablethespecifiedexternalalarm.Usetheno
formtodisabletheselectedalarm.

Usage Examples
Thefollowingisanexampleofhowtousethealarmenableexternalinput<1n>command.
(config-sys-alarm shelf 1)#alarm enable external-input 1
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86678

2-2412

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm enable module [comm-failure|removed|restart]


Usethealarmenablemodulecommandstoenablethedifferentmodulerelatedalarms.

Syntax Description
commfailure

Amodulehasacommunicationsfailure

removed

Amodulehasbeenremovedorinserted

restart

Amodulehasbeenrestarted

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablemodule[comm
failure|removed|restart]command.
(config-sys-alarm shelf 1)#alarm enable module removed
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable module comm-failure
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable module restart
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66202

6TANV57CLI-35A

2-2413

Total Access/NetVanta Carrier CLI Dictionary

alarm enable power-fail ac


UsethealarmenablepowerfailaccommandtoenableanddisabletheACpowerfailalarm.

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablepowerfailaccommand.
(config-sys-alarm)#alarm enable power-fail ac
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
77421

2-2414

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm enable power-fail dc [a|b]


UsethealarmenablepowerfaildccommandtoenableanddisabletheDCpowerfailalarms.

Syntax Description
a

PowerinputA

PowerinputB

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablepowerfaildc[a|b]command.
(config-sys-alarm)#alarm enable power-fail dc a
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
86647

6TANV57CLI-35A

2-2415

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shelf <2-4> [link-down|link-removed]


Usethealarmenableshelf<24>commandtoenabletheshelfalarms.

Syntax Description
linkdown

Communicationlinkdown

linkremoved

Communicationlinkremoved

Usage Examples
Thefollowingisanexampleofhowtousethealarmenableshelf<24>[linkdown|link
removed]command.
Use following command to enable the shelf link down alarm for shelf 2.
(config-sys-alarm shelf 1)#alarm enable shelf 2 link-down
(config-sys-alarm shelf 1)#
Use following command to enable an alarm to be declared when shelf 2 has
been removed from the HDX configuration.
(config-sys-alarm shelf 1)#alarm enable shelf 2 link-removed
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86758

2-2416

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm enable test audible-relay [critical|major|minor]


Usethealarmenableaudiblerelaycommandstoenabletheaudiblerelayalarmswhenthe
userhasinitiatedatestontheaudiblerelays.

Syntax Description
critical

Criticalrelayisintest

major

Majorrelayisintest

minor

Minorrelayisintest

Usage Examples
Thefollowingisanexampleofhowtousethealarmenabletestaudiblerelay
[critical|major|minor]command.
(config-sys-alarm shelf 1)#alarm enable test audible-relay critical
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable test audible-relay major
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable test audible-relay minor
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86770

6TANV57CLI-35A

2-2417

Total Access/NetVanta Carrier CLI Dictionary

alarm enable test visual-relay [critical|major|minor]


Usethealarmenableaudiblerelaycommandstoenablethevisualrelayalarmswhentheuser
hasinitiatedatestonthevisualrelays.

Syntax Description
critical

Criticalrelayisintest

major

Majorrelayisintest

minor

Minorrelayisintest

Usage Examples
Thefollowingisanexampleofhowtousethealarmenabletestvisualrelay
[critical|major|minor]command.
(config-sys-alarm shelf 1)#alarm enable test visual -relay critical
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable test visual -relay major
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm enable test visual -relay minor
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
86775

2-2418

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm level external-input <1-n>


[alert|critical|information|major|minor]
Usethealarmlevelexternalinput<1n>commandtosettheselectedexternalalarmseverity
level

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelexternalinput<1n>
[alert|critical|information|major|minor]command.
(config-sys-alarm shelf 1)#alarm level external-input 1 information
(config-sys-alarm shelf 1)
(config-sys-alarm shelf 1)#alarm level external-input 1 alert
(config-sys-alarm shelf 1)
config-sys-alarm shelf 1)#alarm level external-input 1 minor
(config-sys-alarm shelf 1)
(config-sys-alarm shelf 1)#alarm level external-input 1 major
(config-sys-alarm shelf 1)
(config-sys-alarm shelf 1)#alarm level external-input 1 critical
(config-sys-alarm shelf 1)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

6TANV57CLI-35A

2-2419

Total Access/NetVanta Carrier CLI Dictionary

Command ID
87280

2-2420

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm level module removed [critical|major|minor]


Usethealarmlevelmoduleremovedcommandstosetthemoduleremovedalarmseverity
level

Syntax Description
critical

Critical

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelmoduleremoved
[critical|major|minor]command.
(config-sys-alarm shelf 1)#alarm level module removed minor
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm level module removed major
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm level module removed critical
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46524

6TANV57CLI-35A

2-2421

Total Access/NetVanta Carrier CLI Dictionary

alarm level power-fail ac [alert|critical|information|major|minor]


Usethealarmlevelpowerfailac[alert|critical|information|major|minor]commandto
configurethealarmseveritylevelfortheACpowerfailalarm.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelpowerfailac[alert|critical|infor
mation|major|minor]command.
(config-sys-alarm)#alarm level power-fail ac major
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
77426

2-2422

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm level power-fail dc a


[alert|critical|information|major|minor]
Usethealarmlevelpowerfaildca[alert|critical|information|major|minor]commandto
configurethealarmseveritylevelfortheDCinputApowerfailalarm.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelpowerfaildca[alert|critical|infor
mation|major|minor]command.
(config-sys-alarm)#alarm level power-fail dc a major
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
77432

6TANV57CLI-35A

2-2423

Total Access/NetVanta Carrier CLI Dictionary

alarm level power-fail dc b


[alert|critical|information|major|minor]
Usethealarmlevelpowerfaildcb[alert|critical|information|major|minor]commandto
configurethealarmseveritylevelfortheDCinputBpowerfailalarm.

Syntax Description
alert

Alert

critical

Critical

information

Informational

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelpowerfaildcb[alert|critical|infor
mation|major|minor]command.
(config-sys-alarm)#alarm level power-fail dc b major
(config-sys-alarm)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1)

Command ID
77438

2-2424

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

alarm level switch removed [critical|major|minor]


Usethealarmlevelswitchremovedcommandtosettheseveritylevelforaswitchmodule
removedalarm.

Syntax Description
critical

Critical

major

Major

minor

Minor

Usage Examples
Thefollowingisanexampleofhowtousethealarmlevelswitchremoved
[critical|major|minor]command.
(config-sys-alarm shelf 1)#alarm level switch removed minor
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm level switch removed major
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#alarm level switch removed critical
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46554

6TANV57CLI-35A

2-2425

Total Access/NetVanta Carrier CLI Dictionary

chronology [ascending|descending]
Usethechronologycommandtosettheorderinwhichalarmsaredisplayedusingtheshow
alarmcommand.

Syntax Description
chronology

Settheorderthatthealarmlogisdisplayed

ascending

Ascendingchronologicalorder(mostrecentlast)

descending

Descendingchronologicalorder(mostrecentfirst)

Usage Examples
Thefollowingisanexampleofhowtousethechronology[ascending|descending]command.
(config-sys-alarm shelf 1)#chronology descending
(config-sys-alarm shelf 1)#
(config-sys-alarm shelf 1)#chronology ascending
(config-sys-alarm shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66170

2-2426

6TANV57CLI-35A

Section 2, Commands - System Alarm Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
77963

6TANV57CLI-35A

2-2427

Total Access/NetVanta Carrier CLI Dictionary

System Management EVC Configuration Command Set


UsethesystemManagementEvccommandsettoconfiguremanagementconnectivitytothe
system.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#system-management-evc
ChassisId(config-sys-mgmt-evc)#

ThefollowingisalistofcommandsavailableintheSystemManagementEVCConfiguration
CommandSet.
connectmenportefmgroup[<shelf/slot/group>|WORD]
connectmenportethernet<shelf/slot/port>
connectmenportgigabitethernet<shelf/slot/port>
connectmenportlaggroup<shelf/slot/group>
connectuniethernet<shelf/slot/port>
connectunigigabitethernet<shelf/slot/port>
exit
ipaddress[A.B.C.D|dhcp]
ipaddressA.B.C.DA.B.C.D
menpri<07>
shutdown
stag<14094>

2-2428

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

connect men-port efm-group [<shelf/slot/group>|WORD]


Usetheconnectmenportefmgroup<shelf/slot/group>commandtoaddanEFMgroupto
thesystemmanagementEVC.Usethenoformofthiscommandtodisconnectaportfromthe
systemmanagementEVC.ThesystemmanagementEVCallowsformorethanoneporttobe
connected.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportefmgroup[<shelf/slot/
group>|WORD]command.
(config-sys-mgmt-evc)#connect men-port efm-group 1/0/1
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwithTotalAccess3000or5000systems,oneportcanbeautocon
figuredtoallowmanagementaccess.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65599

6TANV57CLI-35A

2-2429

Total Access/NetVanta Carrier CLI Dictionary

connect men-port ethernet <shelf/slot/port>


Usetheconnectmenportethernet<shelf/slot/port>commandtoaddanEthernetporttothe
systemmanagementEVC.Usethenoformofthiscommandtodisconnectaportfromthe
systemmanagementEVC.ThesystemmanagementEVCallowsformorethanoneporttobe
connected.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportethernet<shelf/slot/port>
command.
(config-sys-mgmt-evc)#connect men-port ethernet 1/0/3
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwiththeTotalAccess3000or5000systems,oneportcanbe
autoconfiguredtoallowmanagementaccess.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1)

Command ID
65591

2-2430

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

connect men-port gigabit-ethernet <shelf/slot/port>


Usetheconnectmenportgigabitethernet<shelf/slot/port>commandtoaddagigabit
ethernetporttothesystemmanagementEVC.Usethenoformofthiscommandtodisconnect
aportfromthesystemmanagementEVC.ThesystemmanagementEVCallowsformorethan
oneporttobeconnected.

Usage Examples
Thefollowingisanexampleofhowtousetheconnectmenportgigabitethernet<shelf/slot/
port>command.
(config-sys-mgmt-evc)#connect men-port gigabit-ethernet 1/0/1
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwithTotalAccess3000or5000systems,oneportcanbeautocon
figuredtoallowmanagementaccess.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV834(1200633G6),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
65595

6TANV57CLI-35A

2-2431

Total Access/NetVanta Carrier CLI Dictionary

connect men-port lag-group <shelf/slot/group>


Usetheconnectmenportlaggroup<shelf/slot/group>commandtoconfigurewhichlag
grouptheselectedEVCisappliedto.Usethenoformofthiscommandtoremovealaggroup
astheMENport.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV8044(1172804G1)

Command ID
120344

2-2432

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

connect uni ethernet <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1187010L1),SCMwithBridging(1187011G1),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1)

Command ID
104357

6TANV57CLI-35A

2-2433

Total Access/NetVanta Carrier CLI Dictionary

connect uni gigabit-ethernet <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV834
(1200633G6),NV838(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
117347

2-2434

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
71276

6TANV57CLI-35A

2-2435

Total Access/NetVanta Carrier CLI Dictionary

ip address [A.B.C.D|dhcp]
Syntax Description
A.B.C.D

IPAddress

dhcp

EnableDHCPclient

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),SCMwithBridging(1187011G1),
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82217

2-2436

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

ip address A.B.C.D A.B.C.D


UsetheipaddressA.B.C.DA.B.C.DcommandtodefinethemanagementIPaddressforthe
unit.UsethenoformofthiscommandtoremovetheconfiguredmanagementIPaddress.

Syntax Description
A.B.C.D

IPAddress

Usage Examples
ThefollowingisanexampleofhowtousetheipaddressA.B.C.DA.B.C.Dcommand.
(config-sys-mgmt-evc)#ip address 10.44.4.73 255.255.0.0
(config-sys-mgmt-evc)#

Functional Notes
UsethefirstA.B.C.DinputtodesignatethemanagementIPaddress.UsethesecondA.B.C.D
inputtodesignatetheIPsubnetmask.
WhenusedinconjunctionwithTotalAccess3000or5000systems,theIPaddressis
configureduponconnection.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
82219

6TANV57CLI-35A

2-2437

Total Access/NetVanta Carrier CLI Dictionary

men-pri <0-7>
Usethemenpri<07>commandtosettheprioritygiventoframessourcedbythesystem.The
priorityvalueappearsasthePbitintheVLANtagoftheframe.Usethenoformofthis
commandtorestorethedefaultvalue.

Usage Examples
Thefollowingisanexampleofhowtousethemenpri<07>command.
(config-sys-mgmt-evc)#men-pri 5
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwithTotalAccess3000or5000systems,theMENpriorityis
configureduponconnection.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
82234

2-2438

6TANV57CLI-35A

Section 2, Commands - System Management EVC Configuration Command Set

shutdown
UsetheshutdowncommandtodisablethesystemmanagementEVC.Usethenoformofthis
commandtoenablethesystemmanagementEVC.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the system management EVC:
(config-sys-mgmt-evc)#shutdown
(config-sys-mgmt-evc)#
! To enable the system management EVC:
(config-sys-mgmt-evc)#no shutdown
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwiththeTotalAccess3000or5000systems,thisvalueisset
automaticallytoenabled.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
65541

6TANV57CLI-35A

2-2439

Total Access/NetVanta Carrier CLI Dictionary

s-tag <1-4094>
UsethiscommandtospecifytheVLANIDofthesystemmanagementEVC.Usethenoform
ofthiscommandtodefaultthissetting.

Usage Examples
Thefollowingisanexampleofhowtousethestag<14094>command.
Set the management EVC's VLAN ID to 99.
(config-sys-mgmt-evc)#s-tag 99
(config-sys-mgmt-evc)#
Restore the management EVC's VLAN ID to the default value.
(config-sys-mgmt-evc)#no s-tag
(config-sys-mgmt-evc)#

Functional Notes
WhenusedinconjunctionwiththeTotalAccess3000or5000systems,thisvaluewillbeset
automaticallyuponconnection.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
65568

2-2440

6TANV57CLI-35A

Section 2, Commands - System Privilege Security Configuration Command Set

System Privilege Security Configuration Command Set


UsetheSystemPrivilegeSecurityConfigurationcommandsettoconfigureparameters
associatedwiththeselectedprivilegelevel.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#security
ChassisId(config-sec)#system-privilege admin
ChassisId(config-sec-priv name)#

ThefollowingisalistofcommandsavailableintheSystemPrivilegeSecurityConfiguration
CommandSet.
accountexpiration<20365>
exit
passwordexpiration<20365>

6TANV57CLI-35A

2-2441

Total Access/NetVanta Carrier CLI Dictionary

account-expiration <20-365>
Usetheaccountexpiration<20365>commandtosettheaccountexpirationtimeforthe
specifiedsystemprivilegelevel.Theaccountexpirationtimeisthenumberofdaysof
inactivityuntiltheaccountexpires.TheaccountexpirationmustbeenabledattheSystem
PrivilegeSecurityConfigurationlevel.Changingtheaccountexpirationtimeforaspecified
systemprivilegelevelchangestheexpirationtimeforallcurrentandfutureaccountsassigned
tothatprivilegelevel,includingthoseaccountsadjustedattheUsernameSecurityConfigu
rationlevel.TheexpirationtimeforindividualaccountscanbeadjustedattheUsername
SecurityConfigurationlevel.Usethenoformofthiscommandtosettheexpirationtimefor
thespecifiedsecurityprivilegeleveltothedefaultsettingof90days.

Usage Examples
Thefollowingisanexampleofhowtousetheaccountexpiration<20365>command.
! To specify the expiration time for the system privilege level
(config-sec-priv test)#account-expiration 33
(config-sec-priv test)#
! To set the account expiration for the system privilege level to the
default
(config-sec-priv test)#no account-expiration
(config-sec-priv test)#

Functional Notes
Thevalidrangefortheexpirationtimeis20to365days.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64587

2-2442

6TANV57CLI-35A

Section 2, Commands - System Privilege Security Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80693

6TANV57CLI-35A

2-2443

Total Access/NetVanta Carrier CLI Dictionary

password-expiration <20-365>
Usethepasswordexpiration<20365>commandtosetthepasswordexpirationtimeofthe
systemprivilegelevel.Usethenoformtosettheexpirationtimetothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethepasswordexpiration<20365>command.
(config-sec-priv test)#password-expiration 33
(config-sec-priv test)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
77748

2-2444

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

System Timing Configuration Command Set


UsetheSystemTimingConfigurationCommandSettoconfiguretimingoptionsforeach
shelf
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#system-timing <shelf>
ChassisId(config-sys-timing shelf x)#

ThefollowingisalistofcommandsavailableintheSystemTimingConfigurationCommand
Set.
alarmenablesource[primaryfailed|secondaryfailed|switch]
exit
externalprimaryhopcount<0255>
externalprimarypriority<0255>
externalprimaryquality[donotuse|sonet|synchronized|transit]
externalprimaryqualitystratum[1|2|3|3e|4]
externalprimarytype[bitsd4|bitsg704|bitsonesdensity|composite|compositenpbo]
externalsecondaryhopcount<0255>
externalsecondarypriority<0255>
externalsecondaryquality[donotuse|sonet|synchronized|transit]
externalsecondaryqualitystratum[1|2|3|3e|4]
externalsecondarytype[bitsd4|bitsg704|bitsonesdensity|composite|compositenpbo]
revertive
revertivehopcount
sourcefallbackexternal[primary|secondary]
sourcefallbackinterfacegigabitethernet<shelf/slot/port>
sourcefallbackinterfacegigabitethernet<shelf/slot/port>fixed
sourcefallbackinterfacetengigabitethernet<shelf/slot/port>
sourcefallbackinterfacetengigabitethernet<shelf/slot/port>fixed
sourcefallbackinternal
sourcefallbackloopainterfacet3<shelf/slot/port>
sourcefallbackloopbinterfacet3<shelf/slot/port>
sourceprimaryexternal[primary|secondary]
sourceprimaryinterfacegigabitethernet<shelf/slot/port>
sourceprimaryinterfacegigabitethernet<shelf/slot/port>fixed
sourceprimaryinterfacetengigabitethernet<shelf/slot/port>
sourceprimaryinterfacetengigabitethernet<shelf/slot/port>fixed
sourceprimaryinternal
sourceprimaryloopainterfacet3<shelf/slot/port>
sourceprimaryloopbinterfacet3<shelf/slot/port>

6TANV57CLI-35A

2-2445

Total Access/NetVanta Carrier CLI Dictionary

sourcesecondaryexternal[primary|secondary]
sourcesecondaryinterfacegigabitethernet<shelf/slot/port>
sourcesecondaryinterfacegigabitethernet<shelf/slot/port>fixed
sourcesecondaryinterfacetengigabitethernet<shelf/slot/port>
sourcesecondaryinterfacetengigabitethernet<shelf/slot/port>fixed
sourcesecondaryinternal
sourcesecondaryloopainterfacet3<shelf/slot/port>
sourcesecondaryloopbinterfacet3<shelf/slot/port>

2-2446

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

alarm enable source [primary-failed|secondary-failed|switch]


Thealarmenablesource[primaryfailed|secondaryfailed]commandenablesthealarmfor
thespecifiedtimingsource.Iftheprimaryfailedalarmhasbeenenabledandtheprimary
timingsourcefails,analarmwillbeactivated.Usethenoformofthiscommandtodisablethe
specifiedalarm.

Syntax Description
primaryfailed

Primarytimingsourcefailed

secondaryfailed

Secondarytimingsourcefailed

switch

Timingsourceswitchhasoccured

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablesource[primary
failed|secondaryfailed|switch]command.
(config)#system-timing 1
(config-sys-timing shelf 1)#alarm enable source primary-failed
(config-sys-timing shelf 1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
87637

6TANV57CLI-35A

2-2447

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
80685

2-2448

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

external primary hop-count <0-255>


Theexternalprimaryhopcount<0255>commandconfiguresthehopcountfortheexternal
primarytimingsource.Thehopcountisthenumberofnodesbetweenasourceandadesti
nation.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46716

6TANV57CLI-35A

2-2449

Total Access/NetVanta Carrier CLI Dictionary

external primary priority <0-255>


Theexternalprimarypriority<0255>commandsetsthepriorityoftheexternalprimary
timingsource.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46715

2-2450

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

external primary quality [do-notuse|sonet|synchronized|transit]


Theexternalprimaryquality[donotuse|sonet|synchronized|transit]commandisusedto
selectthequalityoftheexternalprimarytimingsource.Alsorefertotheexternalprimary
qualitystratum[1|2|3|3e|4]command.Usingthenoformofthiscommandsetsthequality
tothedefault.

Syntax Description
donotuse

Sourceisnotusable

sonet

SourceisSONET

synchronized

Sourceissynchronized

transit

Sourceistransit

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46136

6TANV57CLI-35A

2-2451

Total Access/NetVanta Carrier CLI Dictionary

external primary quality stratum [1|2|3|3e|4]


Theexternalprimaryqualitystratum[1|2|3|3e|4]commandisusedtoselectthequalityof
theexternalprimarytimingsource.Alsorefertotheexternalprimaryquality[donot
use|sonet|synchronized|transit]command.Usingthenoformofthiscommandsetsthe
qualitytothedefault.

Syntax Description
1

SourceisStratum1

SourceisStratum2

SourceisStratum3

3e

SourceisStratum3e

SourceisStratum4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46707

2-2452

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

external primary type [bits-d4|bits-g704|bits-onesdensity|composite|composite-npbo]


Theexternalprimarytype[bitsd4|bitsonedensity|composite|compositenpbo]commandis
usedtospecifythetypeofexternalprimarytimingsource.Usingthenoformofthis
commandsetsthetypetothedefault.

Syntax Description
bitsd4

BITSD4framing

bitsg704

E1BITSclockframedperG.704table4a

bitsonesdensity

BITSonesdensity/unframedallones

composite

Composite64kHzclock

compositenpbo

Composite64kHzclockwithnophasebuildout

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46135

6TANV57CLI-35A

2-2453

Total Access/NetVanta Carrier CLI Dictionary

external secondary hop-count <0-255>


Theexternalsecondaryhopcount<0255>commandconfiguresthehopcountforthe
externalsecondarytimingsource.Thehopcountisthenumberofnodesbetweenasource
andadestination.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46730

2-2454

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

external secondary priority <0-255>


Theexternalsecondarypriority<0255>commandsetsthepriorityoftheexternalsecondary
timingsource.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46729

6TANV57CLI-35A

2-2455

Total Access/NetVanta Carrier CLI Dictionary

external secondary quality [do-notuse|sonet|synchronized|transit]


Theexternalsecondaryquality[donotuse|sonet|synchronized|transit]commandisusedto
selectthequalityoftheexternalsecondarytimingsource.Alsorefertotheexternalsecondary
qualitystratum[1|2|3|3e|4]command.Usingthenoformofthiscommandsetsthequality
tothedefault.

Syntax Description
donotuse

Sourceisnotusable

sonet

SourceisSONET

synchronized

Sourceissynchronized

transit

Sourceistransit

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46140

2-2456

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

external secondary quality stratum [1|2|3|3e|4]


Theexternalsecondaryqualitystratum[1|2|3|3e|4]commandisusedtoselectthequalityof
theexternalsecondarytimingsource.Alsorefertotheexternalsecondaryquality[donot
use|sonet|synchronized|transit]command.Usingthenoformofthiscommandsetsthe
qualitytothedefault.

Syntax Description
1

SourceisStratum1

SourceisStratum2

SourceisStratum3

3e

SourceisStratum3e

SourceisStratum4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
64863

6TANV57CLI-35A

2-2457

Total Access/NetVanta Carrier CLI Dictionary

external secondary type [bits-d4|bits-g704|bits-onesdensity|composite|composite-npbo]


Theexternalsecondarytype[bitsd4|bitsonedensity|composite|compositenpbo]command
isusedtospecifythetypeofexternalsecondarytimingsource.Usingthenoformofthis
commandsetsthetypetothedefault.

Syntax Description
bitsd4

BITSd4framming

bitsg704

E1BITSclockframedperG.704table4a

bitsonesdensity

BITSonesdensity/unframedallones

composite

Composite64kHzclock

compositenpbo

Composite64kHzclockwithnophasebuildout

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46139

2-2458

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

revertive
Therevertivecommand(inthesystemtimingcommandset)enablesrevertivetimingmode.
Ifprovisionedasrevertive,thentheactivetimingreferencerevertstotheprimaryreferenceif
thestatusisokay.Usethenoformofthiscommandtoenablenonrevertivetimingmode.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46173

6TANV57CLI-35A

2-2459

Total Access/NetVanta Carrier CLI Dictionary

revertive hop-count
Therevertivehopcountcommandenablesrevertivehopcounttimingmode.Ifprovisioned
asrevertivehopcount,thentheactivetimingreferencerevertstothetimingreferencewith
thesmallesthopcount(ifthestatusofthattimingreferenceisokay).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46144

2-2460

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source fallback external [primary|secondary]


Thesourcefallbackexternal[primary|secondary]commandconfigurestimingforthefallback
sourcetobederivedfromthespecifiedexternaltimingsource.Therearetwoexternal
sources,theprimaryandsecondaryexternalinputs.

Syntax Description
primary

Timingderivedfromprimaryexternalclocksource

secondary

Timingderivedfromsecondaryexternalclocksource

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
64855

6TANV57CLI-35A

2-2461

Total Access/NetVanta Carrier CLI Dictionary

source fallback interface gigabit-ethernet <shelf/slot/port>


Thesourcefallbackinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedasthefallbacktimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46702

2-2462

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source fallback interface gigabit-ethernet <shelf/slot/port>


fixed
Thesourcefallbackinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedasthefallbacktimingreference.

Syntax Description
<shelf/slot/port>

EnterGigabitEthernetportnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100180

6TANV57CLI-35A

2-2463

Total Access/NetVanta Carrier CLI Dictionary

source fallback interface ten-gigabit-ethernet <shelf/slot/port>


Thesourcefallbackinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedasthefallbacktimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46704

2-2464

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source fallback interface ten-gigabit-ethernet <shelf/slot/port>


fixed
Thesourcefallbackinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedasthefallbacktimingreference.

Syntax Description
<shelf/slot/port>

EnterTenGigabitEthernetportnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100181

6TANV57CLI-35A

2-2465

Total Access/NetVanta Carrier CLI Dictionary

source fallback internal


Thesourcefallbackinternalcommandspecifiestheinternalclockasthefallbacktiming
reference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46694

2-2466

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source fallback loop-a interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
96319

6TANV57CLI-35A

2-2467

Total Access/NetVanta Carrier CLI Dictionary

source fallback loop-b interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
95575

2-2468

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source primary external [primary|secondary]


Thesourceprimaryexternal[primary|secondary]commandconfigurestimingforthe
primarysourcetobederivedfromthespecifiedexternaltimingsource.Therearetwo
externalsources,theprimaryandsecondaryexternalinputs.

Syntax Description
primary

Timingderivedfromprimaryexternalclocksource

secondary

Timingderivedfromsecondaryexternalclocksource

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
64851

6TANV57CLI-35A

2-2469

Total Access/NetVanta Carrier CLI Dictionary

source primary interface gigabit-ethernet <shelf/slot/port>


Thesourceprimaryinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedastheprimarytimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46674

2-2470

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source primary interface gigabit-ethernet <shelf/slot/port>


fixed
Thesourceprimaryinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedastheprimarytimingreference.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100176

6TANV57CLI-35A

2-2471

Total Access/NetVanta Carrier CLI Dictionary

source primary interface ten-gigabit-ethernet <shelf/slot/port>


Thesourceprimaryinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedastheprimarytimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46675

2-2472

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source primary interface ten-gigabit-ethernet <shelf/slot/port>


fixed
Thesourceprimaryinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedastheprimarytimingreference.

Syntax Description
<shelf/slot/port>

Specifiedinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100177

6TANV57CLI-35A

2-2473

Total Access/NetVanta Carrier CLI Dictionary

source primary internal


Thesourceprimaryinternalcommandspecifiestheinternalclockastheprimarytiming
reference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46628

2-2474

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source primary loop-a interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
95454

6TANV57CLI-35A

2-2475

Total Access/NetVanta Carrier CLI Dictionary

source primary loop-b interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
95458

2-2476

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source secondary external [primary|secondary]


Thesourcesecondaryexternal[primary|secondary]commandconfigurestimingforthe
secondarysourcetobederivedfromthespecifiedexternaltimingsource.Therearetwo
externalsources,theprimaryandsecondaryexternalinputs.

Syntax Description
primary

Timingderivedfromprimaryexternalclocksource

secondary

Timingderivedfromsecondaryexternalclocksource

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46677

6TANV57CLI-35A

2-2477

Total Access/NetVanta Carrier CLI Dictionary

source secondary interface gigabit-ethernet <shelf/slot/port>


Thesourcesecondaryinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedasthesecondarytimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46683

2-2478

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source secondary interface gigabit-ethernet <shelf/slot/port>


fixed
Thesourcesecondaryinterfacegigabitethernet<shelf/slot/port>specifiesthegigabitethernet
porttobeusedasthesecondarytimingreference.

Syntax Description
<shelf/slot/port>

EnterGigabitEthernetportnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100178

6TANV57CLI-35A

2-2479

Total Access/NetVanta Carrier CLI Dictionary

source secondary interface ten-gigabit-ethernet <shelf/slot/


port>
Thesourcesecondaryinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedasthesecondarytimingreference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
46684

2-2480

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source secondary interface ten-gigabit-ethernet <shelf/slot/


port> fixed
Thesourcesecondaryinterfacetengigabitethernet<shelf/slot/port>specifiesthetengigabit
ethernetporttobeusedasthesecondarytimingreference.

Syntax Description
<shelf/slot/port>

EnterTenGigabitEthernetportnumber

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1)

Command ID
100179

6TANV57CLI-35A

2-2481

Total Access/NetVanta Carrier CLI Dictionary

source secondary internal


Thesourcesecondaryinternalcommandspecifiestheinternalclockasthesecondarytiming
reference.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM(1187020E1),SM(1187020L1),SM2GE(1187020G1),SM2GE(1187020G2),SM10GE
(1187025G1),SM10GE(1187030G1)

Command ID
46676

2-2482

6TANV57CLI-35A

Section 2, Commands - System Timing Configuration Command Set

source secondary loop-a interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
95462

6TANV57CLI-35A

2-2483

Total Access/NetVanta Carrier CLI Dictionary

source secondary loop-b interface t3 <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1)

Command ID
95466

2-2484

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

T1 Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface t1 <shelf/slot/port>
ChassisId(config-t1 x/x/x[:chan])#

Functional Notes
T1commandset
ThefollowingisalistofcommandsavailableintheT1InterfaceConfigurationCommandSet.
alarmenable[ais|lof|los|rai]
alarmenableshutdownmaintenance
alarmlevelais[alert|critical|information|major|minor]
alarmlevellof[alert|critical|information|major|minor]
alarmlevellos[alert|critical|information|major|minor]
alarmlevelrai[alert|critical|information|major|minor]
alarmtrap[ais|lof|los|rai]
autoinserviceenable
autoinservicetimeout<19999>
clocksource[internal|line]
coding[ami|b8zs]
descriptionLINE
exit
framing[d4|esf]
lbolong[0|15|7]
lboshort<0655>
remoteloopback[csu|fdl|feac|niu]
shutdown[maintenance|unassigned]
thresholdscvl15minute<02147483647>
thresholdscvl24hour<02147483647>
thresholdscvp15minute<02147483647>
thresholdscvp24hour<02147483647>
thresholdsesl15minute<0900>
thresholdsesl24hour<086400>
thresholdsesp15minute<0900>
thresholdsesp24hour<086400>
thresholdssesp15minute<0900>
thresholdssesp24hour<086400>
thresholdsuasp15minute<0900>

6TANV57CLI-35A

2-2485

Total Access/NetVanta Carrier CLI Dictionary

thresholdsuasp24hour<086400>
timeoutloopback<09999>

2-2486

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

alarm enable [ais|lof|los|rai]


Usecommandalarmenabletoenableais,lof,los,andraialarms

Syntax Description
ais

AlarmIndicationSignal

lof

LossofFrame

los

LossofSignal

rai

RemoteAlarmIndication

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90070

6TANV57CLI-35A

2-2487

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
111832

2-2488

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

alarm level ais [alert|critical|information|major|minor]


UsethealarmlevelaiscommandtospecifytheAISalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90160

6TANV57CLI-35A

2-2489

Total Access/NetVanta Carrier CLI Dictionary

alarm level lof [alert|critical|information|major|minor]


UsethealarmlevellofcommandtospecifytheLOFalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90148

2-2490

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

alarm level los [alert|critical|information|major|minor]


UsethealarmlevelloscommandtospecifytheLOSalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),DS1FrameRelay32PortAM(1187803G3)

Command ID
90142

6TANV57CLI-35A

2-2491

Total Access/NetVanta Carrier CLI Dictionary

alarm level rai [alert|critical|information|major|minor]


UsethealarmlevelraicommandtospecifytheRAIalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90154

2-2492

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

alarm trap [ais|lof|los|rai]


UsethealarmtrapcommandstoenabletheenterpriseSNMPtrapfortheselectedalarm(AIS,
LOF,LOS,RAI)

Syntax Description
ais

AlarmIndicationSignal

lof

LossofFrame

los

LossofSignal

rai

RemoteAlarmIndication

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90091

6TANV57CLI-35A

2-2493

Total Access/NetVanta Carrier CLI Dictionary

auto-in-service enable
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
104382

2-2494

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

auto-in-service timeout <1-9999>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3)

Command ID
104384

6TANV57CLI-35A

2-2495

Total Access/NetVanta Carrier CLI Dictionary

clock source [internal|line]


Syntax Description
internal

Timingderivedfromlocalclock

line

Timingderivedfromreceiveinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
64840

2-2496

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

coding [ami|b8zs]
Syntax Description
ami

AlternateMarkInversion

b8zs

Binary8ZeroSuppression

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),DS1FrameRelay32PortAM(1187803G3),EFMDS1AM
(1187802L1),NV814(1200637G4),NV818(1200637G2)

Command ID
45467

6TANV57CLI-35A

2-2497

Total Access/NetVanta Carrier CLI Dictionary

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedT1interface.Usethenoformof
thiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-t1 1/0/1)#description T1 Port 1
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
78727

2-2498

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
78804

6TANV57CLI-35A

2-2499

Total Access/NetVanta Carrier CLI Dictionary

framing [d4|esf]
Syntax Description
d4

D4Superframe(SF)

esf

ExtendedSuperframe

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
DS1PPPAM(1187803G2),CHDS3PPPAM(1187220G1),DS1FrameRelay32PortAM
(1187803G3),CHDS3FrameRelay3PortAM(1187220G3),EFMDS3CHAM(1187810G1),
EFMDS1AM(1187802L1),NV814(1200637G4),NV818(1200637G2)

Command ID
45485

2-2500

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

lbo long [0|15|7]


UsethelbolongcommandtoconfigurethelinebuildoutfortheT1interface.Usethenoform
ofthiscommandtoreturntothedefaultsetting.

Syntax Description
0

0dBlineattenuation

15

15dBlineattenuation

7.5dBlineattenuation

Usage Examples
Thefollowingisanexampleofhowtousethelbolong[0|15|7]command.
(config-t1 1/0/1)#lbo long 0
(config-t1 1/0/1)#
(config-t1 1/0/1)#lbo long 7
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2)

Command ID
45476

6TANV57CLI-35A

2-2501

Total Access/NetVanta Carrier CLI Dictionary

lbo short <0-655>


UsethelboshortcommandtoconfigurethelinebuildoutfortheT1interface.Usetheno
formofthiscommandtoreturntothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethelboshort<0655>command.
(config-t1 1/0/1)#lbo short 200
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),DS1FrameRelay32PortAM
(1187803G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45475

2-2502

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

remote-loopback [csu|fdl|feac|niu]
UsetheremoteloopbackcommandtoconfiguretheT1interfacetorespondtoaremotely
initiatedloopback.Usethenoformofthiscommandtodisablethisfeature.

Syntax Description
csu

EnableacceptanceofCSUloopbackrequests

fdl

EnableacceptanceofFDLloopbackrequests

feac

EnableacceptanceofFEACloopbackrequests

niu

EnableacceptanceofNIUloopbackrequests

Usage Examples
Thefollowingisanexampleofhowtousetheremoteloopback[csu|fdl|feac|niu]command.
(config-t1 1/0/1)#remote-loopback csu
(config-t1 1/0/1)#
(config-t1 1/0/1)#remote-loopback fdl

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45517

6TANV57CLI-35A

2-2503

Total Access/NetVanta Carrier CLI Dictionary

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-t1 1/0/1)#shutdown
(config-t1 1/0/1)#
! To disable the interface:
(config-t1 1/0/1)#shutdown unassigned
(config-t1 1/0/1)#
! To enable the interface:
(config-t1 1/0/1)#no shutdown
(config-t1 1/0/1)#
! To enable the interface but inhibit alarms:
(config-t1 1/0/1)#shutdown maintenance
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

2-2504

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

Command ID
78688

6TANV57CLI-35A

2-2505

Total Access/NetVanta Carrier CLI Dictionary

thresholds cv-l 15-minute <0-2147483647>


Usethethresholdscvl15minutecommandtoconfigurethe15minuteCodeViolationsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl15minute<02147483647>
command.
(config-t1 1/0/1)#thresholds cv-l 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),DS1FrameRelay32PortAM
(1187803G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45600

2-2506

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds cv-l 24-hour <0-2147483647>


Usethethresholdscvl24hourcommandtoconfigurethe24hourCodeViolationsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl24hour<02147483647>
command.
(config-t1 1/0/1)#thresholds cv-l 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),DS1FrameRelay32PortAM
(1187803G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45602

6TANV57CLI-35A

2-2507

Total Access/NetVanta Carrier CLI Dictionary

thresholds cv-p 15-minute <0-2147483647>


Usethethresholdscvp15minutecommandtoconfigurethe15minuteCodeViolationsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvp15minute<02147483647>
command.
(config-t1 1/0/1)#thresholds cv-p 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45560

2-2508

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds cv-p 24-hour <0-2147483647>


Usethethresholdscvp24hourcommandtoconfigurethe24hourCodeViolationsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvp24hour<02147483647>
command.
(config-t1 1/0/1)#thresholds cv-p 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45562

6TANV57CLI-35A

2-2509

Total Access/NetVanta Carrier CLI Dictionary

thresholds es-l 15-minute <0-900>


Usethethresholdsesl15minutecommandtoconfigurethe15minuteErroredSecondsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl15minute<0900>command.
(config-t1 1/0/1)#thresholds es-l 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),DS1FrameRelay32PortAM
(1187803G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45590

2-2510

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds es-l 24-hour <0-86400>


Usethethresholdsesl24hourcommandtoconfigurethe24hourErroredSecondsLine
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl24hour<086400>command.
(config-t1 1/0/1)#thresholds es-l 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),DS1FrameRelay32PortAM
(1187803G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45592

6TANV57CLI-35A

2-2511

Total Access/NetVanta Carrier CLI Dictionary

thresholds es-p 15-minute <0-900>


Usethethresholdsesp15minutecommandtoconfigurethe15minuteErroredSecondsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesp15minute<0900>command.
(config-t1 1/0/1)#thresholds es-p 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45550

2-2512

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds es-p 24-hour <0-86400>


Usethethresholdsesp24hourcommandtoconfigurethe24hourErroredSecondsPath
performancemonitoringthreshold.Usethenoformofthiscommandtoreturnthethreshold
toitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesp24hour<086400>command.
(config-t1 1/0/1)#thresholds es-p 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45552

6TANV57CLI-35A

2-2513

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses-p 15-minute <0-900>


Usethethresholdssesp15minutecommandtoconfigurethe15minuteSeverelyErrored
SecondsPathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturn
thethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesp15minute<0900>command.
(config-t1 1/0/1)#thresholds ses-p 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45570

2-2514

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds ses-p 24-hour <0-86400>


Usethethresholdssesp24hourcommandtoconfigurethe24hourSeverelyErroredSeconds
Pathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturnthe
thresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesp24hour<086400>command.
(config-t1 1/0/1)#thresholds ses-p 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45572

6TANV57CLI-35A

2-2515

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas-p 15-minute <0-900>


Usethethresholdsuasp15minutecommandtoconfigurethe15minuteUnavailable
SecondsPathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturn
thethresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp15minute<0900>command.
(config-t1 1/0/1)#thresholds uas-p 15-minute 20
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45580

2-2516

6TANV57CLI-35A

Section 2, Commands - T1 Interface Configuration Command Set

thresholds uas-p 24-hour <0-86400>


Usethethresholdsuasp24hourcommandtoconfigurethe24hourUnavailableSeconds
Pathperformancemonitoringthreshold.Usethenoformofthiscommandtoreturnthe
thresholdtoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp24hour<086400>command.
(config-t1 1/0/1)#thresholds uas-p 24-hour 100
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45582

6TANV57CLI-35A

2-2517

Total Access/NetVanta Carrier CLI Dictionary

timeout loopback <0-9999>


Usethetimeoutcommandtoconfigureatimeoutusedtoautomaticallyremoveanyactive
loopbackortestpatternontheT1interface.Usethenoformofthiscommandtoreturnthe
timeouttoitsdefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethetimeoutloopback<09999>command.
(config-t1 1/0/1)#timeout loopback 10
(config-t1 1/0/1)#
(config-t1 1/0/1)#timeout test-pattern 10
(config-t1 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CHAM(1187810G1),EFMDS1AM(1187802L1),DS1PPPAM(1187803G2),CH
DS3PPPAM(1187220G1),DS1FrameRelay32PortAM(1187803G3),CHDS3FrameRelay3
PortAM(1187220G3),NV814(1200637G4),NV818(1200637G2)

Command ID
45535

2-2518

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

T3 Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface t3 <shelf/slot/port>
ChassisId(config-t3 x/x/x)#

ThefollowingisalistofcommandsavailableintheT3InterfaceConfigurationCommandSet.
alarmenable[ais|lof|los|rai]
alarmenableshutdownmaintenance
alarmlevelais[alert|critical|information|major|minor]
alarmlevellof[alert|critical|information|major|minor]
alarmlevellos[alert|critical|information|major|minor]
alarmlevelrai[alert|critical|information|major|minor]
alarmtrap[ais|lof|los|rai]
autoinserviceenable
autoinservicetimeout<19999>
clocksource[internal|line]
descriptionLINE
exit
framing[cbit|m23]
remoteloopback
shutdown[maintenance|unassigned]
thresholdscvcpp15minute<02147483647>
thresholdscvcpp24hour<02147483647>
thresholdscvl15minute<02147483647>
thresholdscvl24hour<02147483647>
thresholdscvpp15minute<02147483647>
thresholdscvpp24hour<02147483647>
thresholdsescpp15minute<0900>
thresholdsescpp24hour<086400>
thresholdsesl15minute<0900>
thresholdsesl24hour<086400>
thresholdsespp15minute<0900>
thresholdsespp24hour<086400>
thresholdssefsp15minute<0900>
thresholdssefsp24hour<086400>
thresholdssescpp15minute<0900>
thresholdssescpp24hour<086400>
thresholdssespp15minute<0900>

6TANV57CLI-35A

2-2519

Total Access/NetVanta Carrier CLI Dictionary

thresholdssespp24hour<086400>
thresholdsuasp15minute<0900>
thresholdsuasp24hour<086400>
timeoutloopback<09999>

2-2520

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

alarm enable [ais|lof|los|rai]


UsecommandalarmenabletoenableAIS,LOF,LOSandRAIalarms

Syntax Description
ais

AlarmIndicationSignal

lof

LossofFrame

los

LossofSignal

rai

RemoteAlarmIndication

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90058

6TANV57CLI-35A

2-2521

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3)

Command ID
110648

2-2522

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

alarm level ais [alert|critical|information|major|minor]


UsethealarmlevelaiscommandtospecifytheAISalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90120

6TANV57CLI-35A

2-2523

Total Access/NetVanta Carrier CLI Dictionary

alarm level lof [alert|critical|information|major|minor]


UsethealarmlevellofcommandtospecifytheLOFalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90108

2-2524

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

alarm level los [alert|critical|information|major|minor]


UsethealarmlevelloscommandtospecifytheLOSalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90102

6TANV57CLI-35A

2-2525

Total Access/NetVanta Carrier CLI Dictionary

alarm level rai [alert|critical|information|major|minor]


UsethealarmlevelraicommandtospecifytheRAIalarmlevel(critical,major,minor,alertor
information).

Syntax Description
alert

Alert

critical

Critical

information

Information

major

Major

minor

Minor

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90114

2-2526

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

alarm trap [ais|lof|los|rai]


UsethealarmtrapcommandstoenabletheenterpriseSNMPtrapfortheselectedalarm(AIS,
LOF,LOS,RAI)

Syntax Description
ais

AlarmIndicationSignal

lof

LossofFrame

los

LossofSignal

rai

RemoteAlarmIndication

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
CHDS3PPPAM(1187220G1),CHDS3FrameRelay3PortAM(1187220G3)

Command ID
90081

6TANV57CLI-35A

2-2527

Total Access/NetVanta Carrier CLI Dictionary

auto-in-service enable
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3)

Command ID
104386

2-2528

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

auto-in-service timeout <1-9999>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3)

Command ID
104388

6TANV57CLI-35A

2-2529

Total Access/NetVanta Carrier CLI Dictionary

clock source [internal|line]


Usetheclocksourcecommandtoconfigurethesourcetimingusedfortheinterface.Theclock
specifiedusingtheclocksourcecommandisalsothesystemmasterclock.Usethenoformof
thiscommandtoreturntothedefaultvalue.UsageExamplesThefollowingexample
configurestheunittorecoverclockingfromthecircuit:(config)#interfacet31/1(configt31/
1)#clocksourceloop

Syntax Description
internal

Timingderivedfromlocalclock

line

Timingderivedfromreceiveinterface

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV873(1200639G1)

Command ID
64880

2-2530

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedT3interface.Usethenoformof
thiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-t3 1/0/1)#description T3 Port 1
(config-t3 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
78723

6TANV57CLI-35A

2-2531

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
78802

2-2532

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

framing [cbit|m23]
Syntax Description
cbit

CbitFraming

m23

M23Framing

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42525

6TANV57CLI-35A

2-2533

Total Access/NetVanta Carrier CLI Dictionary

remote-loopback
Usetheremoteloopbackcommandtoenablethedetectionofloopbackrequestsorginated
fromtheremotedevice.Thenoformofthecommanddisablesdetection.

Usage Examples
Thefollowingisanexampleofhowtousetheremoteloopbackcommand.
(config-t3 1/0/1)#no remote-loopback

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42544

2-2534

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-t3 1/0/1)#shutdown
(config-t3 1/0/1)#
! To disable the interface:
(config-t3 1/0/1)#shutdown unassigned
(config-t3 1/0/1)#
! To enable the interface:
(config-t3 1/0/1)#no shutdown
(config-t3 1/0/1)#
! To enable the interface but inhibit alarms:
(config-t3 1/0/1)#shutdown maintenance
(config-t3 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

6TANV57CLI-35A

2-2535

Total Access/NetVanta Carrier CLI Dictionary

Command ID
78689

2-2536

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds cvcp-p 15-minute <0-2147483647>


Usethethresholdscvcpp15minutecommandtoconfigure15minuteCodeViolationsCPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvcpp15minute<02147483647>
command.
(config-t3 1/0/1)#thresholds cvcp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42632

6TANV57CLI-35A

2-2537

Total Access/NetVanta Carrier CLI Dictionary

thresholds cvcp-p 24-hour <0-2147483647>


Usethethresholdscvcpp24hourcommandtoconfigure24hourCodeViolationsCPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvcpp24hour<02147483647>
command.
(config-t3 1/0/1)#thresholds cvcp-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42634

2-2538

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds cv-l 15-minute <0-2147483647>


Usethethresholdscvl15minutecommandtoconfigure15minuteCodeViolationsLine
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl15minute<02147483647>
command.
(config-t3 1/0/1)#thresholds cv-l 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42572

6TANV57CLI-35A

2-2539

Total Access/NetVanta Carrier CLI Dictionary

thresholds cv-l 24-hour <0-2147483647>


Usethethresholdscvl24hourcommandtoconfigure24hourCodeViolationsLineperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvl24hour<02147483647>
command.
(config-t3 1/0/1)#thresholds cv-l 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42574

2-2540

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds cvp-p 15-minute <0-2147483647>


Usethethresholdscvpp15minutecommandtoconfigure15minuteCodeViolationsPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdscvpp15minute<02147483647>
command.
(config-t3 1/0/1)#thresholds cvp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42592

6TANV57CLI-35A

2-2541

Total Access/NetVanta Carrier CLI Dictionary

thresholds cvp-p 24-hour <0-2147483647>


Usethethresholdscvpp24hourcommandtoconfigure24hourCodeViolationsPbitPath
performancemonitoringthreshold.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42594

2-2542

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds escp-p 15-minute <0-900>


Usethethresholdsescpp15minutecommandtoconfigure15minuteErroredSecondsCPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsescpp15minute<0900>command.
(config-t3 1/0/1)#thresholds escp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42612

6TANV57CLI-35A

2-2543

Total Access/NetVanta Carrier CLI Dictionary

thresholds escp-p 24-hour <0-86400>


Usethethresholdsescpp24hourcommandtoconfigure24hourErroredSecondsCPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsescpp24hour<086400>command.
(config-t3 1/0/1)#thresholds escp-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42614

2-2544

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds es-l 15-minute <0-900>


Usethethresholdsesl15minutecommandtoconfigure15minuteErroredSecondsLine
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl15minute<0900>command.
(config-t3 1/0/1)#thresholds es-l 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42562

6TANV57CLI-35A

2-2545

Total Access/NetVanta Carrier CLI Dictionary

thresholds es-l 24-hour <0-86400>


Usethethresholdsesl24hourcommandtoconfigure24hourErroredSecondsLineperfor
mancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesl24hour<086400>command.
(config-t3 1/0/1)#thresholds es 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42564

2-2546

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds esp-p 15-minute <0-900>


Usethethresholdsespp15minutecommandtoconfigure15minuteErroredSecondsPbit
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsespp15minute<0900>command.
(config-t3 1/0/1)#thresholds esp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42582

6TANV57CLI-35A

2-2547

Total Access/NetVanta Carrier CLI Dictionary

thresholds esp-p 24-hour <0-86400>


Usethethresholdsespp24hourcommandtoconfigure24hourErroredSecondsPbitPath
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsespp24hour<086400>command.
(config-t3 1/0/1)#thresholds esp-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42584

2-2548

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds sefs-p 15-minute <0-900>


Usethethresholdssefsp15minutecommandtoconfigure15minuteSeverelyErroredFrame
SecondsPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssefsp15minute<0900>command.
(config-t3 1/0/1)#thresholds sefs-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42642

6TANV57CLI-35A

2-2549

Total Access/NetVanta Carrier CLI Dictionary

thresholds sefs-p 24-hour <0-86400>


Usethethresholdssefsp24hourcommandtoconfigure24hourSeverelyErroredFrame
SecondsPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssefsp24hour<086400>command.
(config-t3 1/0/1)#thresholds sefs-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42644

2-2550

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds sescp-p 15-minute <0-900>


Usethethresholdssescpp15minutecommandtoconfigure15minuteSeverelyErrored
SecondsCPbitPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssescpp15minute<0900>
command.
(config-t3 1/0/1)#thresholds sescp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42622

6TANV57CLI-35A

2-2551

Total Access/NetVanta Carrier CLI Dictionary

thresholds sescp-p 24-hour <0-86400>


Usethethresholdssescpp24hourcommandtoconfigure24hourSeverelyErroredSeconds
CPbitPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssescpp24hour<086400>
command.
(config-t3 1/0/1)#thresholds sescp-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42624

2-2552

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds sesp-p 15-minute <0-900>


Usethethresholdssespp15minutecommandtoconfigure15minuteSeverelyErrored
SecondsPbitPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssespp15minute<0900>command.
(config-t3 1/0/1)#thresholds sesp-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42602

6TANV57CLI-35A

2-2553

Total Access/NetVanta Carrier CLI Dictionary

thresholds sesp-p 24-hour <0-86400>


Usethethresholdssespp24hourcommandtoconfigure24hourSeverelyErroredSeconds
PbitPathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssespp24hour<086400>command.
(config-t3 1/0/1)#thresholds cvp-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42604

2-2554

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

thresholds uas-p 15-minute <0-900>


Usethethresholdsuasp15minutecommandtoconfigure15minuteUnavailableSeconds
Pathperformancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp15minute<0900>command.
(config-t3 1/0/1)#thresholds uas-p 15-minute 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42652

6TANV57CLI-35A

2-2555

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas-p 24-hour <0-86400>


Usethethresholdsuasp24hourcommandtoconfigure24hourUnavailableSecondsPath
performancemonitoringthreshold.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasp24hour<086400>command.
(config-t3 1/0/1)#thresholds uas-p 24-hour 20

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
42654

2-2556

6TANV57CLI-35A

Section 2, Commands - T3 Interface Configuration Command Set

timeout loopback <0-9999>


Usethetimeoutloopback*commandtoconfigurethetimeoutusedtoautomaticallyremove
anyactiveloopbackonthisinterface

Usage Examples
Thefollowingisanexampleofhowtousethetimeoutloopback<09999>command.
(config-t3 1/0/1)#timeout loopback 100

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
EFMDS3CCAM(1187260G1),EFMDS3CHAM(1187810G1),CHDS3PPPAM(1187220G1),
CHDS3FrameRelay3PortAM(1187220G3),NV873(1200639G1)

Command ID
64698

6TANV57CLI-35A

2-2557

Total Access/NetVanta Carrier CLI Dictionary

Temperature Sensor Configuration Command Set


Usethetemperaturesensorconfigurationcommandsettoconfigureparametersassociated
withaparticulartemperaturesensorinthesystem.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#temperature-sensor <shelf/slot/sensor>
ChassisId(config-temp-sensor x/x/x)#

ThefollowingisalistofcommandsavailableintheTemperatureSensorConfiguration
CommandSet.
exit

2-2558

6TANV57CLI-35A

Section 2, Commands - Temperature Sensor Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
TA500023inchFan(1187080L1),NV814(1200637G4),NV818(1200637G2),NV824
(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T(1172832G1),NV834
(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP(1172839G1),NV838
OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844(1200635G2),NV873
(1200639G1),NV8044(1172804G1)

Command ID
80694

6TANV57CLI-35A

2-2559

Total Access/NetVanta Carrier CLI Dictionary

Ten Gigabit-Ethernet Interface Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface ten-gigabit-ethernet <shelf/slot/port>
ChassisId(config-ten-giga-eth x/x/x)#

ThefollowingisalistofcommandsavailableintheTenGigabitEthernetInterfaceConfigu
rationCommandSet.
alarmenable[downstreamfault|heartbeatloss|lacptimeout|linkdownenterprise|link
downrfc2863|portmode|upstreamnode]
alarmenablepluggable[fault|missing|speedmismatch|temperaturehigh|unknown]
alarmenableshutdownmaintenance
descriptionLINE
downlink
ethernet[cfm|evcadvertisement]
ethernetcfmenable
ethernetcfmmep<18191>WORDWORDdown
ethernetoamenable
exit
lacpgrammarstandbyaggregation
lacpmode[active|passive]
mtu<150010000>
shutdown[maintenance|unassigned]
stagdei
subtendedhostipaddressA.B.C.DA.B.C.D
subtendedhostipdefaultgatewayA.B.C.D
subtendedhostipfileserverdefaulthostA.B.C.D
subtendedhostmode[disabled|sender]
subtendedhostsnmpserverchassisidWORD
subtendedhostsnmpservercommunityreadonlyWORD
subtendedhostsnmpservercommunityreadwriteWORD
subtendedhoststag[<14094>|systemmanagementevc]
subtendedhoststagpriority<07>
thresholdsbroadcasts15minute<04294967295>
thresholdsbroadcasts24hour<04294967295>
thresholdsdiscards15minute<04294967295>
thresholdsdiscards24hour<04294967295>
thresholdserrors15minute<04294967295>
thresholdserrors24hour<04294967295>

2-2560

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholdsgiants15minute<04294967295>
thresholdsgiants24hour<04294967295>
thresholdsmulticasts15minute<04294967295>
thresholdsmulticasts24hour<04294967295>
thresholdsrunts15minute<04294967295>
thresholdsrunts24hour<04294967295>

6TANV57CLI-35A

2-2561

Total Access/NetVanta Carrier CLI Dictionary

alarm enable [downstream-fault|heartbeat-loss|lacptimeout|link-down-enterprise|link-down-rfc2863|portmode|upstream-node]


Syntax Description
downstreamfault

Downstreamnodeisinthenotreadystate

heartbeatloss

Treenetworkingheartbeatloss

lacptimeout

LACPtimeouthasoccured

linkdownenterprise

Enterpriselinkdownalarm

linkdownrfc2863

RFC2863linkdownalarm

portmode

Portmodedoesnotmatchconnecteddevice

upstreamnode

Upstreamnodecannotprocessprotectionmessages

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1)

Command ID
83041

2-2562

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

alarm enable pluggable [fault|missing|speedmismatch|temperature-high|unknown]


Syntax Description
fault

Devicefault

missing

Missingdevice

speedmismatch

Speedcapabilitymismatch

temperaturehigh

Overtemperature

unknown

Unknowndevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
102018

6TANV57CLI-35A

2-2563

Total Access/NetVanta Carrier CLI Dictionary

alarm enable shutdown maintenance


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
117287

2-2564

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedtengigabitethernetinterface.Use
thenoformofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-ten-giga-eth 1/0/1)#description 10GE Port 1
(config-ten-giga-eth 1/0/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78715

6TANV57CLI-35A

2-2565

Total Access/NetVanta Carrier CLI Dictionary

downlink
UsethedownlinkcommandtosetthisinterfaceasadownlinktoanotherTotalAccess5000or
OSPDSLAM.ThisisusedinmultinodeorHDXapplicationsforredundancyandtiming
purposes.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97309

2-2566

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

ethernet [cfm|evc-advertisement]
Syntax Description
cfm

ConnectivityFaultManagement,enableonthisinterface

evcadvertisement

EnableEVCAdvertisement

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1),10GEthernetMuxponder(1174101F1)

Command ID
65068

6TANV57CLI-35A

2-2567

Total Access/NetVanta Carrier CLI Dictionary

ethernet cfm enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
120315

2-2568

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

ethernet cfm mep <1-8191> WORD WORD down


Syntax Description
<18191>

MEPidentifier

WORD

NameofthemaintenancedomaincontainingthisMEP

WORD

NameofthemaintenanceassociationcontainingthisMEP

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65074

6TANV57CLI-35A

2-2569

Total Access/NetVanta Carrier CLI Dictionary

ethernet oam enable


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148042

2-2570

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
78798

6TANV57CLI-35A

2-2571

Total Access/NetVanta Carrier CLI Dictionary

lacp grammar standby-aggregation


Usethelacpgrammarstandbyaggregationcommandtospecifyhowastandbymodule
buildsLACPDUframes.Whenenabled,theaggregationbitisalwayssetonthestandby
moduleLACPDUs.Thesyncbitisusedtoindicatethattheactivemoduleisreadytoreceive
traffic.Whendisabled,theaggregationbitisusedtoindicatethatthestandbymoduleisready
toreceivetraffic.

Usage Examples
Thefollowingisanexampleofhowtousethelacpgrammarstandbyaggregationcommand.
(config-gig-eth 1/A/1)#lacp grammar standby-aggregation
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97303

2-2572

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

lacp mode [active|passive]


Usethelacpmode[active|passive]commandtosettheLinkAggregationControlProtocol
(LACP)participationfortheselectedinterface.

Syntax Description
active

Activenegotiatingstate

passive

Passivenegotiatingstate

Usage Examples
Thefollowingisanexampleofhowtousethelacpmode[active|passive]command.
(config-gig-eth 1/A/1)# lacp mode active
(config-gig-eth 1/A/1)#

Functional Notes
LACPallowsanetworkdevicetonegotiateanautomaticbundlingoflinksbysendingLACP
packetstothepeer(directlyconnecteddevicethatalsoimplementsLACP).LACPworksby
sendingframes(LACPDUs)downalllinksthathavetheprotocolenabled.Ifadeviceis
presentontheotherendofthelinkthatalsohasLACPenabled,itwillalsoindependently
sendframesalongthesamelinksenablingthetwounitstodetectmultiplelinksbetween
themselvesandthencombinethemintoasinglelogicallink.LACPcanbeconfiguredinone
oftwomodes:ActiveorPassive.InActivemodeitwillalwayssendframesalongthe
configuredlinks.InPassivemodehowever,itactsasspeakwhenspokento,andtherefore
canbeusedasawayofcontrollingaccidentalloops(aslongastheotherdeviceisinactive
mode).

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
97299

6TANV57CLI-35A

2-2573

Total Access/NetVanta Carrier CLI Dictionary

mtu <1500-10000>
Functional Notes
150010000isthestandardrange,butsomeproductsmaysupportasmallersubset.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
153980

2-2574

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

shutdown [maintenance|unassigned]
Usetheshutdowncommandtoadministrativelydisabletheinterface(nodataispassed
through).Usethenoshutdowncommandtoenabletheinterfaceandallowittopassdata.If
supported,usetheshutdownmaintenancecommandtoenabletheinterfacebutinhibit
alarms.

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-gig-eth 1/A/1)#shutdown
(config-gig-eth 1/A/1)#
! To disable the interface:
(config-gig-eth 1/A/1)#shutdown unassigned
(config-gig-eth 1/A/1)#
! To enable the interface:
(config-gig-eth 1/A/1)#no shutdown
(config-gig-eth 1/A/1)#
! To enable the interface but inhibit alarms:
(config-gig-eth 1/A/1)#shutdown maintenance
(config-gig-eth 1/A/1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

6TANV57CLI-35A

2-2575

Total Access/NetVanta Carrier CLI Dictionary

Command ID
78693

2-2576

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

s-tag-dei
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1),NV8044
(1172804G1)

Command ID
98129

6TANV57CLI-35A

2-2577

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip address A.B.C.D A.B.C.D


ThiscommandisusedtosettheIPaddressandthesubnetmaskforthesubtendedhost.Use
thenoformofthiscommandtodefaultthesevalues.

Syntax Description
A.B.C.D

IPaddress

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148051

2-2578

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

subtended-host ip default-gateway A.B.C.D


Thiscommandisusedtosetthedefaultgatewayforthesubtendedhost.Usethenoformof
thiscommandtodefaultthisvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148054

6TANV57CLI-35A

2-2579

Total Access/NetVanta Carrier CLI Dictionary

subtended-host ip file-server default host A.B.C.D


ThiscommandisusedtosettheIPaddressforIPhostfiletransfers.Usethenoformofthis
commandtodefaultthisvalue.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148058

2-2580

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

subtended-host mode [disabled|sender]


Syntax Description
disabled

Doesnotsendoracceptsubtendedhostparameters

sender

Sendssubtendedhostparameterstoconnecteddevice

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148081

6TANV57CLI-35A

2-2581

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server chassis-id WORD


ThiscommandisusedtosetthechassisidforthesubtendedhostsSNMPserver.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148071

2-2582

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

subtended-host snmp-server community read-only WORD


Optional.Grantsreadonlyaccess,allowingretrievalofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148069

6TANV57CLI-35A

2-2583

Total Access/NetVanta Carrier CLI Dictionary

subtended-host snmp-server community read-write WORD


Optional.Grantsreadwriteaccess,allowingretrievalandmodificationofMIBobjects.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148067

2-2584

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

subtended-host s-tag [<1-4094>|system-management-evc]


Syntax Description
<14094>

VIDoftheinbandmanagmentVlan

systemmanagementevc

InheritVIDfromtheSystemManagementEVC

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148059

6TANV57CLI-35A

2-2585

Total Access/NetVanta Carrier CLI Dictionary

subtended-host s-tag-priority <0-7>


ThiscommandsetsthepriorityfortheinbandmanagementVLAN.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1)

Command ID
148063

2-2586

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds broadcasts 15-minute <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65059

6TANV57CLI-35A

2-2587

Total Access/NetVanta Carrier CLI Dictionary

thresholds broadcasts 24-hour <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65061

2-2588

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds discards 15-minute <0-4294967295>


Usethethresholdsdiscards15minute*commandtoconfigurethediscardedframecount
alarmthresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65049

6TANV57CLI-35A

2-2589

Total Access/NetVanta Carrier CLI Dictionary

thresholds discards 24-hour <0-4294967295>


Usethethresholdsdiscards24hour*commandtoconfigurethediscardedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65051

2-2590

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds errors 15-minute <0-4294967295>


Usethethresholdserrors15minute*commandtoconfiguretheCRCerrorcountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65034

6TANV57CLI-35A

2-2591

Total Access/NetVanta Carrier CLI Dictionary

thresholds errors 24-hour <0-4294967295>


Usethethresholdserrors24hour*commandtoconfiguretheCRCerrorcountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65036

2-2592

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds giants 15-minute <0-4294967295>


Usethethresholdsgiants15minute*commandtoconfiguretheoversizedframecountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65044

6TANV57CLI-35A

2-2593

Total Access/NetVanta Carrier CLI Dictionary

thresholds giants 24-hour <0-4294967295>


Usethethresholdsgiants24hour*commandtoconfiguretheoversizedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65046

2-2594

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds multicasts 15-minute <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65054

6TANV57CLI-35A

2-2595

Total Access/NetVanta Carrier CLI Dictionary

thresholds multicasts 24-hour <0-4294967295>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65056

2-2596

6TANV57CLI-35A

Section 2, Commands - Ten Gigabit-Ethernet Interface Configuration Command Set

thresholds runts 15-minute <0-4294967295>


Usethethresholdsrunts15minute*syntaxtoconfiguretheundersizedframecountalarm
thresholdsin15minuteintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65039

6TANV57CLI-35A

2-2597

Total Access/NetVanta Carrier CLI Dictionary

thresholds runts 24-hour <0-4294967295>


Usethethresholdsrunts24hour*syntaxtoconfiguretheundersizedframecountalarm
thresholdsin24hourintervals.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
10GEthernetMuxponder(1174101F1),SM10GE(1187025G1),SM10GE(1187030G1)

Command ID
65041

2-2598

6TANV57CLI-35A

Section 2, Commands - TL1 Configuration Command Set

TL1 Configuration Command Set


UsetheTL1ConfigurationcommandsettoconfigureTL1parametersthatcanbeusedfor
flowthroughprovisioning.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#tl1
ChassisId(config-tl1)#

ThefollowingisalistofcommandsavailableintheTL1ConfigurationCommandSet.
chassisidtidsync
echo
equipmentid<09>
exit
logmax<25200>
tidWORD

6TANV57CLI-35A

2-2599

Total Access/NetVanta Carrier CLI Dictionary

chassis-id-tid-sync
UsethechassisidtidsynccommandtoforcetheTIDequaltothesystemname.Usetheno
formtodisablethisfeatureandallowtheTIDandsystemnametobeseparate.

Usage Examples
Thefollowingisanexampleofhowtousethechassisidtidsynccommand.
(config-tl1)#chassis-id-tid-sync
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
66278

2-2600

6TANV57CLI-35A

Section 2, Commands - TL1 Configuration Command Set

echo
UsetheechocommandinordertoechoTL1inputbacktotheuserinterface.Usethenoform
todisablethisfeature.

Usage Examples
Thefollowingisanexampleofhowtousetheechocommand.
(config-tl1)#echo
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63470

6TANV57CLI-35A

2-2601

Total Access/NetVanta Carrier CLI Dictionary

equipment-id <0-9>
Usetheequipmentid<09>commandtosettheequipmentid.Usethenoformtosetthe
equipmentidtothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousetheequipmentid<09>command.
(config-tl1)#equipment-id 9
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
46536

2-2602

6TANV57CLI-35A

Section 2, Commands - TL1 Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
80688

6TANV57CLI-35A

2-2603

Total Access/NetVanta Carrier CLI Dictionary

log-max <25-200>
Usethelogmax<25200>commandtosetthemaximumnumberofTL1logentries.Usethe
noformtothethemaximumnumberofTL1logentriestothedefaultsetting.

Usage Examples
Thefollowingisanexampleofhowtousethelogmax<25200>command.
(config-tl1)#log-max 200
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63479

2-2604

6TANV57CLI-35A

Section 2, Commands - TL1 Configuration Command Set

tid WORD
UsethetidWORDcommandtosettheTIDofthesystem.UsethenoformtosettheTIDto
thedefaultsetting.

Usage Examples
ThefollowingisanexampleofhowtousethetidWORDcommand.
(config-tl1)#tid TA5000
(config-tl1)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
63475

6TANV57CLI-35A

2-2605

Total Access/NetVanta Carrier CLI Dictionary

TWAMP Responder Configuration Command Set


UsetheTWAMPResponderConfigurationCommandSettoconfiguretheTwoWayActive
MeasurementProtocol(TWAMP)responderfunctionthatcanbeusedtomeasureService
LevelAgreementparameters.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#probe responder twamp
ChassisId(config-twamp-responder)#

ThefollowingisalistofcommandsavailableintheTWAMPResponderConfiguration
CommandSet.
controlsourceport[<165535>|twampcontrol]
controltimeout<165535>
exit
maxsessions<1n>
shutdown
testtimeout<165535>

2-2606

6TANV57CLI-35A

Section 2, Commands - TWAMP Responder Configuration Command Set

control source-port [<1-65535>|twamp-control]


UsethecontrolsourceportcommandtospecifytheTwoWayActiveMeasurementProtocol
(TWAMP)sourcecontrolport.Usethenoformofthiscommandtoreturntothedefault
setting.Variationsofthiscommandinclude:controlsourceportowampcontrolcontrolsource
portUsageExamplesThefollowingexamplespecifiestheOWAMPcontrolportasthesource
controlportfortheTWAMPresponder:(config)#proberespondertwamp(configresponder
twamp)#controlsourceportowampcontrol<port>

Syntax Description
<165535>

TCPControlPort

twampcontrol

TWAMPcontrolport(862)

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45797

6TANV57CLI-35A

2-2607

Total Access/NetVanta Carrier CLI Dictionary

control timeout <1-65535>


Usethecontroltimeout*commandtoautomaticallyshutdownanyTWAMPcontrolservers
thathavenoactivereflectortestsessionsrunningandhavenotreceivedacontrolsession
packetfromtheTWAMPclientoverthecontroltimeoutperiod.

Usage Examples
Thefollowingisanexampleofhowtousethecontroltimeout<165535>command.
(config-twamp-responder)#control timeout 300

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45962

2-2608

6TANV57CLI-35A

Section 2, Commands - TWAMP Responder Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentconfigurationmodeandenterthepreviousone.For
example,usingtheexitcommandinaninterfaceconfigurationmodewillactivatetheGlobal
Configurationmode.WhenusingtheexitcommandintheBasicmode,thecurrentsession
willbeterminated.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
46097

6TANV57CLI-35A

2-2609

Total Access/NetVanta Carrier CLI Dictionary

max-sessions <1-n>
Usethemaxsessions*commandtospecifythemaximumnumberofactivereflector
sessions.Usethenoformofthiscommandtorestorethedefaults.

Usage Examples
Thefollowingisanexampleofhowtousethemaxsessions<1n>command.
(config-twamp-responder)#max-sessions 5

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45801

2-2610

6TANV57CLI-35A

Section 2, Commands - TWAMP Responder Configuration Command Set

shutdown
UsetheshutdowncommandtodisabletheTWAMPresponder.Usethenoformofthe
commandtoenabletheresponder.

Usage Examples
Thefollowingisanexampleofhowtousetheshutdowncommand.
! To disable the TWAMP responder:
(config-twamp-responder)#shutdown
(config-twamp-responder)#
! To enable the TWAMP responder:
(config-twamp-responder)#no shutdown
(config-twamp-responder)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45794

6TANV57CLI-35A

2-2611

Total Access/NetVanta Carrier CLI Dictionary

test timeout <1-65535>


Usethetesttimeout<165535>commandtosettheTWAMPtestsessioncontroltimeout
period.ATWAMPtestsessionreflectorthatdoesnotreceiveatestsessionpacketfromthe
TWAMPclientforthespecifiedtime,automaticallyshutsdown.

Usage Examples
Thefollowingisanexampleofhowtousethetesttimeout<165535>command.
(config-twamp-responder)#test timeout 300
(config-twamp-responder)#

Functional Notes
Thevalidrangeforthetimeoutis165535seconds.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
NV814(1200637G4),NV818(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832
(1200718E1),NV832T(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838
(1200633G4),NV838EP(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838
(1200633G7),NV844(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
45809

2-2612

6TANV57CLI-35A

Section 2, Commands - Username Security Configuration Command Set

Username Security Configuration Command Set


UsetheUsernameSecurityConfigurationcommandsettocreatenewuseraccountsorto
modifysecurityparametersfortheselectedusername.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#security
ChassisId(config-sec)#username WORD
ChassisId(config-sec-user name)#

ThefollowingisalistofcommandsavailableintheUsernameSecurityConfiguration
CommandSet.
accountexpiration[<20365>|enable]
disable
exit
lockout
password
passwordexpiration[<20365>|enable]
privilege[admin|config|readonly|readwrite|test]

6TANV57CLI-35A

2-2613

Total Access/NetVanta Carrier CLI Dictionary

account-expiration [<20-365>|enable]
Usetheaccountexpiration[<20365>|enable]commandtosettheexpirationtimeforthe
specifiedaccount.Theaccountexpirationtimeisthenumberofdaysofinactivityuntilthe
accountexpires.TheaccountexpirationmustbeenabledattheUsernameSecurityConfigu
rationlevelandtheSecurityConfigurationlevelfortheaccountexpirationtotakeeffect.If
accountexpirationisdisabledattheSecurityConfigurationlevel,theexpirationtimeforthe
specifiedaccountisignored.

Syntax Description
<20365>

Numberofdaysuntiltheaccountexpires

enable

Enableaccountexpirationforthisaccount

Usage Examples
Thefollowingisanexampleofhowtousetheaccountexpiration[<20365>|enable]
command.
! To specify the expiration time
(config-sec-user newuser)#account-expiration 33
(config-sec-user newuser)#
! To set the expiration time to the default setting
(config-sec-user newuser)#no account-expiration
(config-sec-user newuser)#
! To enable account expiration on the specified account
(config-sec-user newuser)#account-expiration enable
(config-sec-user newuser)#
! To disable account expiration on the specified account
(config-sec-user newuser)#no account-expiration enable
(config-sec-user newuser)#

Functional Notes
Thevalidrangefortheexpirationtimeis20to365days.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

2-2614

6TANV57CLI-35A

Section 2, Commands - Username Security Configuration Command Set

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64632

6TANV57CLI-35A

2-2615

Total Access/NetVanta Carrier CLI Dictionary

disable
Usethedisablecommandtodisabletheselecteduseraccount,sothatitcannotbeusedtolog
intothesystem.Thiscommandcannotdisabletheuseraccountissuingthedisablecommand.

Usage Examples
Thefollowingisanexampleofhowtousethedisablecommand.
(config-sec-user user)#disable
(config-sec-user user)#

Functional Notes
Bydefault,allsecurityuseraccountsareenabled.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64594

2-2616

6TANV57CLI-35A

Section 2, Commands - Username Security Configuration Command Set

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
80692

6TANV57CLI-35A

2-2617

Total Access/NetVanta Carrier CLI Dictionary

lock-out
Usethelockoutcommandtolockouttheusernamespecifiedinthecommandset.Usetheno
formtounlocktheuserandallowfuturelogins.

Usage Examples
Thefollowingisanexampleofhowtousethelockoutcommand.
(config-sec-user newuser)#lock-out
(config-sec-user newuser)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64598

2-2618

6TANV57CLI-35A

Section 2, Commands - Username Security Configuration Command Set

password
Usethepasswordcommandtochangethepasswordfortheselecteduseraccount.

Usage Examples
Thefollowingisanexampleofhowtousethepasswordcommand.
(config-sec-user user)#password
Enter New Password:
Re-enter New Password:
Password Changed
(config-sec-user user)#

Functional Notes
Bydefault,thepasswordissetto?PASSWORD?inallcaps.Thepasswordcanhavea
maximumof16charactersandiscasesensitive.

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64647

6TANV57CLI-35A

2-2619

Total Access/NetVanta Carrier CLI Dictionary

password-expiration [<20-365>|enable]
Usethepasswordexpirationcommandstosetpasswordexpirationoptionsforthegivenuser.

Syntax Description
<20365>

Numberofdaysuntilthepasswordexpires

enable

Enablepasswordexpirationforthisaccount

Usage Examples
Thefollowingisanexampleofhowtousethepasswordexpiration[<20365>|enable]
command.
(config-sec-user newuser)#passwordt-expiration 33
(config-sec-user newuser)#
(config-sec-user newuser)#password-expiration enable
(config-sec-user newuser)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2)

Command ID
64635

2-2620

6TANV57CLI-35A

Section 2, Commands - Username Security Configuration Command Set

privilege [admin|config|read-only|read-write|test]
Usetheprivilege[admin|config|readonly|readwrite|test]commandtosettheprivilege
levelfortheselectedlocaluseraccount.Note:ForCLIsessions,thelocalreadwrite
privilegelevelisequivalenttothelocaltestprivilegelevel.

Syntax Description
admin

Administratorprivileges

config

Configurationaccess

readonly

Readonlyaccess

readwrite

Readwriteaccess

test

Testprivileges

Usage Examples
Thefollowingisanexampleofhowtousetheprivilege[admin|config|readonly|read
write|test]command.
(config-sec-user user)#privilege admin
(config-sec-user user)#

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
SCM(1188010E1),SCM(1187010L1),SCMG2(1187010G2),NV814(1200637G4),NV818
(1200637G2),NV824(1200634G4),NV828(1200634G2),NV832(1200718E1),NV832T
(1172832G1),NV834(1200633G6),NV834T(1172834G1),NV838(1200633G4),NV838EP
(1172839G1),NV838OSP(1172830G1),NV838T(1172838G1),TA838(1200633G7),NV844
(1200635G2),NV873(1200639G1),NV8044(1172804G1)

Command ID
64644

6TANV57CLI-35A

2-2621

Total Access/NetVanta Carrier CLI Dictionary

VDSL Interface Configuration Command Set


UsetheVDSLInterfaceConfigurationCommandSettocreateandmodifytheVDSLinter
faces.
ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#interface vdsl <shelf/slot/port>
ChassisId(config-vdsl x/x/x)#

ThefollowingisalistofcommandsavailableintheVDSLInterfaceConfigurationCommand
Set.
alarmenablelinkdown
deploymentregion<12>scenario<12>otherservice<04>applicationstandard<13>
bandplan<1>bandprofile<17>psdu0<12>psdmask
descriptionLINE
dmtoptionshambandnotch[1.8|10.1|14.0|18.06|21.00|24.89|28.00|3.5|7.0]
dmtoptionssnrmargindownstreammaximum<031>
dmtoptionssnrmargindownstreamminimum<031>
dmtoptionssnrmargindownstreamtarget<031>
dmtoptionssnrmarginupstreammaximum<031>
dmtoptionssnrmarginupstreamminimum<031>
dmtoptionssnrmarginupstreamtarget<031>
exit
latencypathdelaydownstream<01><163>
latencypathdelayupstream<01><163>
latencypathinitpolicydownstream<01>[datarate|inp]
latencypathinitpolicyupstream<01>[datarate|inp]
latencypathinpdownstream<01><016>
latencypathinpupstream<01><016>
latencypathpayloadratedownstreammaximum<01><32150000>
latencypathpayloadratedownstreamminimum<01><32150000>
latencypathpayloadrateupstreammaximum<01><3296000>
latencypathpayloadrateupstreamminimum<01><3296000>
latencypathtypedownstream<01>[fast|interleave|nochannel]
latencypathtypeupstream<01>[fast|interleave|nochannel]
powerbackoffupstream[a|auto|b|c|custom|d|disable|e|f]
rateadaptiondownstream[fixed|startup]
rateadaptionupstream[fixed|startup]
servicemode[adsl2|adsl2+|adsl2+m|adsl2multimode|gdmt|vdsl2]
shutdown[maintenance|unassigned]
thresholdsesdownstream15minute<0900>
thresholdsesupstream15minute<0900>

2-2622

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholdslofdownstream15minute<0900>
thresholdslofupstream15minute<0900>
thresholdslolupstream15minute<0900>
thresholdslosdownstream15minute<0900>
thresholdslosupstream15minute<0900>
thresholdslprsdownstream15minute<0900>
thresholdslprsupstream15minute<0900>
thresholdssesdownstream15minute<0900>
thresholdssesupstream15minute<0900>
thresholdssnrdownstream<099>
thresholdssnrupstream<099>
thresholdsuasdownstream15minute<0900>
thresholdsuasupstream15minute<0900>

6TANV57CLI-35A

2-2623

Total Access/NetVanta Carrier CLI Dictionary

alarm enable link-down


Usethealarmenablelinkdowncommandtoenablethereportingofthelinkdownalarm
trap.Thealarmisofmajorseverityandindicatestheactiveorinactivestatusoftheselected
VDSLphysicalinterface.

Usage Examples
Thefollowingisanexampleofhowtousethealarmenablelinkdowncommand.
(config-vdsl 1/19/1)#alarm enable link-down
VDSL [1/19/1] Link down alarm = Enabled
(config-vdsl 1/19/1)#

Functional Notes
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.
SNMPcrossreference:
IFMIB(rfc2863.mib)ifXTableifLinkUpDownTrapEnable
OID:1.3.6.1.2.1.31.1.1.1.14

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
77974

2-2624

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

deployment region <1-2> scenario <1-2> other-service <0-4>


application-standard <1-3> band-plan <1> band-profile <1-7>
psd-u0 <1-2> psd-mask
ThedeploymentcommandconfigureparametersthatcontrolthebehavioroftheVDSL
interfacebasedonthelocation,expectedenvironment,anddesiredfunctionality.Theseselec
tionscanhaveorderdependenceandthereforerolledupintoasingleverbosecommand.The
deploymentcommandisintendedtominimizeandsimplifythePSDselectionprocessby
limitingoptionsbasedonselections.

Syntax Description
<12>

(1)ANorthAmerica,(2)BEurope

<12>

(1)Cabinet,(2)Exchange

<04>

(0)None,(1)POTS,(2)ISDN,(3)TCM_ISDN,(4)ADSL

<13>

(1)ANSI,(2)ETSI,(3)ITU

<1>

A998

<17>

(1)8A,(2)8B,(3)8C,(4)8D,(5)12A,(6)12B,(7)17A

<12>

(1)Enable,(2)Disable

Usage Examples
Thefollowingisanexampleofhowtousethedeploymentregion<12>scenario<12>other
service<04>applicationstandard<13>bandplan<1>bandprofile<17>psdu0<12>psd
maskcommand.
VDSL-AM(config-vdsl 1/19/1)>deployment region 1 scenario 2 other-service
1 applicatation-standard 3 band-plan 1 band-profile 1 psd-u0 1 psd-mask 1
VDSL config applied

Functional Notes
NotethereisnotdirectSNMPcrossreferenceforthesedeploymentselectionssincethis
wouldcauseorderdependence.ThiscommanddoesresultinafinalspecificPSDselection
thatispresentintheSNMPentries.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfBandProfiles
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.12

6TANV57CLI-35A

2-2625

Total Access/NetVanta Carrier CLI Dictionary

adGenVdsl2LineConfProfileTableadGenVdsl2ConfSpecificPsdSelect
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.13

adGenVdsl2LineConfProfileTableadGenVdsl2ConfUsPsdMaskU0Select
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.14

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
44910

2-2626

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

description LINE
UsethedescriptionLINEcommandtoidentifythespecifiedVDSLinterface.Theidentifi
cationiscustomercontrolledandmaintainedasaconfigurationitemfortheselectedVDSL
interface.Usethenoformofthiscommandtoremoveadescription.

Usage Examples
ThefollowingisanexampleofhowtousethedescriptionLINEcommand.
(config-vdsl 1/19/1)#description 1-800-555-1212
(config-vdsl 1/19/1)#

Functional Notes
TheLINEinputhasamaximumstringlengthof32characters.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2ConfProfileExtTable
adGenVdsl2LineCircuitID
OID:1.3.6.1.4.1.664.5.65.1.5.1.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
78729

6TANV57CLI-35A

2-2627

Total Access/NetVanta Carrier CLI Dictionary

dmt-options hamband-notch
[1.8|10.1|14.0|18.06|21.00|24.89|28.00|3.5|7.0]
Usethedmtoptionshambandnotch[1.8|3.5|7.0|10.1|14.0|18.06|21.00|24.89|28.00]
commandtoenableindividuallynotchingstandardhambandRFIfrequenciesonabandby
bandbasis.Theexactwidthandbandedgesofthesenotchesdependsontheregionselected
bythecurrentselecteddeploymentoptionsregion.Usethenoformofthiscommandto
disableanotchandallowittobeutilizedagain.

Syntax Description
hambandnotch

Enablehambandnotches

1.8

Enablethe1.8Mhzhambandnotch

10.1

Enablethe10.1Mhzhambandnotch

14.0

Enablethe14.0Mhzhambandnotch

18.06

Enablethe18.06Mhzhambandnotch

21.00

Enablethe21.00Mhzhambandnotch

24.89

Enablethe24.89Mhzhambandnotch

28.00

Enablethe28.00Mhzhambandnotch

3.5

Enablethe3.5Mhzhambandnotch

7.0

Enablethe7.0Mhzhambandnotch

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionshambandnotch
[1.8|10.1|14.0|18.06|21.00|24.89|28.00|3.5|7.0]command.
(config-vdsl 1/19/1)#dmt-options hamband-notch 1.8
VDSL [1/19/1] Hamband Notches = 1.8M
(config-vdsl 1/19/1)#

Functional Notes
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfHamBandNotches
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.23

Local Security Permissions


Admin,TechSupport

2-2628

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20109

6TANV57CLI-35A

2-2629

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin downstream maximum <0-31>


Thedmtoptionssnrmargindownstreammaximum[031]commandconfiguresthe
maximumnoisemargintheVTURreceivershalltrytosustain.Ifthenoisemarginisabove
thislevel,thereceivershallattempttoreducethetransmitpowerofthefarendtocomply
withtheselectedvalue.Therangeisfrom0to31dBmargin.Thenoformofthiscommand
returnsthisparametertothedefaultvalueof16dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmargindownstream
maximum<031>command.
VDSL-AM(config-vdsl 1/19/1)>dmt-options snr-margin downstream maximum 16
VDSL [1/19/1] Downstream max SNR = 16 dB

Functional Notes
Themaximummarginmustbegreaterorequalthanthetargetandminimummargins.
Thesevaluesarenotallwaysachievablebutconsideredthedesiredbehaviorifpossibleor
supportedbythecurrentmodulationstandard.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsMaxSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95425

2-2630

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

dmt-options snr-margin downstream minimum <0-31>


Thedmtoptionssnrmargindownstreamminimum[031]commandconfiguresthe
minimumnoisemargintheVTURreceivershalltolerate.Ifthenoisemarginisbelowthis
level,thereceivershallattempttorincreasethetransmitpowerofthefarendtocomplywith
theselectedvalue.Iftheminimummarginvaluecannotbeachieved,alossofmargin(LOM)
failureoccurs.Therangeisfrom0to31dBmargin.Thenoformofthiscommandreturnsthis
parametertothedefaultvalueof0dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmargindownstreamminimum
<031>command.
VDSL-AM(config-vdsl 1/19/1)>dmt-options snr-margin downstream minimum 0
VDSL [1/19/1] Downstream min SNR = 0 dB

Functional Notes
Theminimummarginmustbelessthanorequalthanthetargetandmaximummargins.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsMinSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.5

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95427

6TANV57CLI-35A

2-2631

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin downstream target <0-31>


Thedmtoptionssnrmargindownstreamtarget[031]commandconfiguresthetargetnoise
margintheVTURreceivershalltrytoachieve.Therangeisfrom0to31dBmargin.Theno
formofthiscommandreturnsthisparametertothedefaultvalueof6dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmargindownstreamtarget<0
31>command.
VDSL-AM(config-vdsl 1/19/1)>dmt-options snr-margin downstream target 6
VDSL [1/19/1] Downstream target SNR = 6 dB

Functional Notes
Thetargetmarginmustbelessorequalthanthemaximummarginandgreaterthanorequal
totheminimummargin.
Thesevaluesarenotallwaysachievablebutconsideredatargetfordesiredperformance.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsTargetSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95429

2-2632

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

dmt-options snr-margin upstream maximum <0-31>


Thedmtoptionssnrmarginupstreammaximum[031]commandconfiguresthemaximum
noisemargintheVTUCreceivershalltrytosustain.Ifthenoisemarginisabovethislevel,
thereceivershallattempttoreducethetransmitpowerofthefarendtocomplywiththe
selectedvalue.Therangeisfrom0to31dBmargin.Thenoformofthiscommandreturns
thisparametertothedefaultvalueof16dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmarginupstreammaximum
<031>command.
VDSL-AM(config-vdsl 1/19/1)>dmt-options snr-margin upstream maximum 16
VDSL [1/19/1] Upstream max SNR = 16 dB

Functional Notes
Themaximummarginmustbegreaterorequalthanthetargetandminimummargins.
Thesevaluesarenotallwaysachievablebutconsideredthedesiredbehaviorifpossibleor
supportedbythecurrentmodulationstandard.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsMaxSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.7

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95432

6TANV57CLI-35A

2-2633

Total Access/NetVanta Carrier CLI Dictionary

dmt-options snr-margin upstream minimum <0-31>


Thedmtoptionssnrmarginupstreamminimum[031]commandconfigurestheminimum
noisemargintheVTUCreceivershalltolerate.Ifthenoisemarginisbelowthislevel,the
receivershallattempttorincreasethetransmitpowerofthefarendtocomplywiththe
selectedvalue.Iftheminimummarginvaluecannotbeachieved,alossofmargin(LOM)
failureoccurs.Therangeisfrom0to31dBmargin.Thenoformofthiscommandreturnsthis
parametertothedefaultvalueof0dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmarginupstreamminimum
<031>command.
VDSL-AM(config-vdsl 1/19/1)>dmt-options snr-margin upstream minimum 0
VDSL [1/19/1] Upstream min SNR = 0 dB

Functional Notes
Theminimummarginmustbelessthanorequalthanthetargetandmaximummargins.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsMinSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.8

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95434

2-2634

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

dmt-options snr-margin upstream target <0-31>


Thedmtoptionssnrmarginupstreamtarget[031]commandconfiguresthetargetnoise
margintheVTUCreceivershalltrytoachieve.Therangeisfrom0to31dBmargin.Theno
formofthiscommandreturnsthisparametertothedefaultvalueof6dB.

Usage Examples
Thefollowingisanexampleofhowtousethedmtoptionssnrmarginupstreamtarget<031>
command.
VDSL-AM(config-vdsl 1/19/1)#dmt-options snr-margin upstream target 6
VDSL [1/19/1] Upstream target SNR = 6 dB

Functional Notes
Thetargetmarginmustbelessorequalthanthemaximummarginandgreaterthanorequal
totheminimummargin.
Thesevaluesarenotallwaysachievablebutconsideredatargetfordesiredperformance.

SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsTargetSnrMgn
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.6

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
95436

6TANV57CLI-35A

2-2635

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
78805

2-2636

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path delay downstream <0-1> <1-63>


Usethelatencypathdelaydownstream<03><163>commandtoconfigurethemaximum
delayfromtheVTUCtotheVTURallowedforthespecifiedpath.TheVDSL2standardand
legacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportof
multiplechannels/pathswithdifferentdelaycharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathdelaydownstream<01><163>
command.
(config-vdsl 1/19/1)#latency-path delay downstream 0 8
VDSL [1/19/1] Latency Path 0 Max Downstream Delay = 8 ms
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedelayis0to63milliseconds.Thedefaultdelayis8milliseconds.
Ifamaximumdelayvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedtoavalidmaximumlessthantheselectedvalueinoperationonly.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(forexample,R=0,
S<=1,D=1,delaybound<1msec).
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MaxDelay
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.38

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2637

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20523

2-2638

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path delay upstream <0-1> <1-63>


Usethelatencypathdelayupstream<03><163>commandtoconfigurethemaximumdelay
fromtheVTURtotheVTUCallowedforthespecifiedpath.TheVDSL2standardandlegacy
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithdifferentdelaycharacteristics.

Syntax Description
<01>

Latencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathdelayupstream<01><163>
command.
(config-vdsl 1/19/1)#latency-path delay upstream 0 8
VDSL [1/19/1] Latency Path 0 Max Upstream Delay = 8 ms
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedelayis0to63milliseconds.Thedefaultdelayis8milliseconds.
Ifamaximumdelayvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedtoavalidmaximumlessthantheselectedvalueinoperationonly.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(ieR=0,S<=1,D=1,
delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MaxDelay
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.32

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2639

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20527

2-2640

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path init-policy downstream <0-1> [data-rate|inp]


Usethelatencypathinitpolicydownstream<03>[datarate|inp]commandtoconfigurethe
initializationpolicyusedwhenselectingcoding/framingparametersduringinitialization
fromtheVTUCtotheVTURforthespecifiedpath.TheVDSL2standardandlegacy
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithdifferentcodingparametercharacteristics.Duringinitialization,these
parameterselectionscanbebiasedtomaximizeimpulsenoiseprotectionwithlowerpayload
ratesortheconverse.

Syntax Description
datarate

Maximizedatarate

inp

MaximizeINP

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinitpolicydownstream<01>
[datarate|inp]command.
(config-vdsl 1/19/1)#latency-path init-policy downstream 0 data-rate
VDSL [1/19/1] Latency Path 0 Downstream Init Policy = Data-Rate
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thedefaultpolicyisdatarate.
Currently,path0istheonlysupportedlatencypath.
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0InitPolicy
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.41

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2641

Total Access/NetVanta Carrier CLI Dictionary

Command ID
46995

2-2642

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path init-policy upstream <0-1> [data-rate|inp]


Usethelatencypathinitpolicyupstream<03>[datarate|inp]commandtoconfigurethe
initializationpolicyusedwhenselectingcoding/framingparametersduringinitialization
fromtheVTURtotheVTUCforthespecifiedpath.TheVDSL2standardandlegacy
ADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneoustransportofmultiple
channels/pathswithdifferentcodingparametercharacteristics.Duringinitialization,these
parameterselectionscanbebiasedtomaximizeimpulsenoiseprotectionwithlowerpayload
ratesortheconverse.

Syntax Description
datarate

Maximizedatarate

inp

MaximizeINP

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinitpolicyupstream<01>[data
rate|inp]command.
(config-vdsl 1/19/1)#latency-path init-policy upstream 0 data-rate
VDSL [1/19/1] Latency Path 0 Upstream Init Policy = Data-Rate
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thedefaultpolicyisdatarate.
Currently,path0istheonlysupportedlatencypath.
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0InitPolicy
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.35

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2643

Total Access/NetVanta Carrier CLI Dictionary

Command ID
63278

2-2644

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path inp downstream <0-1> <0-16>


Usethelatencypathinpdownstream<03><016>commandtoconfiguretheminimum
impulsenoiseprotectiondesiredfromtheVTUCtotheVTURforthespecifiedpath.The
VDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimulta
neoustransportofmultiplechannels/pathswithprotectioncharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinpdownstream<01><016>
command.
(config-vdsl 1/19/1)#latency-path inp downstream 0 0.5
VDSL [1/19/1] Latency Path 0 Downstream INP = 0.5
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
ThevalidrangefortheINPis0to16symbols.ThedefaultINPis0.5symbols.
IfamimimumINPvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedinoperationtothelargestvaluesupportedbythatmode.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(forexample,R=0,
S<=1,D=1,delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MinProtection
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.39

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2645

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20580

2-2646

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path inp upstream <0-1> <0-16>


Usethelatencypathinpupstream<03><016>commandtoconfiguretheminimumimpulse
noiseprotectiondesiredfromtheVTURtotheVTUCforthespecifiedpath.TheVDSL2
standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimultaneous
transportofmultiplechannels/pathswithprotectioncharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathinpupstream<01><016>
command.
(config-vdsl 1/19/1)#latency-path inp upstream 0 0.5
VDSL [1/19/1] Latency Path 0 Upstream INP = 0.5
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
ThevalidrangefortheINPis0to16symbols.ThedefaultINPis0.5symbols.
IfamimimumINPvalueexceedsthatallowedbyaselectedoperationalmode,thevalueis
simplylimitedinoperationtothelargestvaluesupportedbythatmode.
Currently,path0istheonlysupportedlatencypath.
Usethelatencypathtypefastcommandtoselectlegacyfasttypeoperation(ieR=0,S<=1,D=1,
delaybound<1msec).
Thisparameterisignoredforlatencypathtypefast.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MinProtection
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.33

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2647

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20583

2-2648

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path payload-rate downstream maximum <0-1> <32150000>


Usethelatencypathpayloadratedownstreammaximum<03><32150000>commandto
configurethemaximumpayloadratefromtheVTUCtotheVTURallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadratedownstream
maximum<01><32150000>command.
(config-vdsl 1/19/1)#latency-path payload-rate downstream maximum 0
100000
VDSL [1/19/1] Latency Path 0 Min Payload Rate Downstream = 100000 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechannel
operation.
Thevalidrangeforthedownstreampayloadrateis32to150,000Kbps.Thedefaultrateis
100,000Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MaxPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.36

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2649

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20552

2-2650

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path payload-rate downstream minimum <0-1> <32150000>


Usethelatencypathpayloadratedownstreamminimum<03><32150000>commandto
configuretheminimumpayloadratefromtheVTUCtotheVTURallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadratedownstream
minimum<01><32150000>command.
(config-vdsl 1/19/1)#latency-path payload-rate downstream minimum 0 32
VDSL [1/19/1] Latency Path 0 Min Payload Rate Downstream = 32 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangeforthedownstreampayloadrateis32to150,000Kbps.Thedefaultrateis32
Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0MinPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.37

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2651

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20558

2-2652

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path payload-rate upstream maximum <0-1> <3296000>


Usethelatencypathpayloadrateupstreammaximum<03><3296000>commandto
configurethemaximumpayloadratefromtheVTURtotheVTUCallowedforthespecified
path.TheVDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovidefor
simultaneoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadrateupstreammaximum
<01><3296000>command.
(config-vdsl 1/19/1)#latency-path payload-rate upstream maximum 0 50000
VDSL [1/19/1] Latency Path 0 Max Payload Rate Upstream = 50000 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhenusingsinglechanneloperation.
Thevalidrangefortheupstreampayloadis32to96,000Kbps.Thedefaultpayloadis50,000
Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MaxPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.30

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2653

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20551

2-2654

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path payload-rate upstream minimum <0-1> <3296000>


Thelatencypathpayloadrateupstreamminimum<03><3296000>commandconfiguresthe
minimumpayloadratefromtheVTURtotheVTUCallowedforthespecifiedpath.The
VDSL2standardandlegacyADSL2+/ADSL2/G.DMT/T1.413standardsprovideforsimulta
neoustransportofmultiplechannels/pathswithdifferentratecharacteristics.

Syntax Description
<01>

Enterlatencypath

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathpayloadrateupstreamminimum
<01><3296000>command.
(config-vdsl 1/19/1)#latency-path payload-rate upstream minimum 0 32
VDSL [1/19/1] Latency Path 0 Min Payload Rate Upstream = 32 Kbps
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwheresinglechanneloperationisto
beused.
Thevalidrangefortheupstreampayloadrateis32to96,000Kbps.Thedefaultrateis32Kbps.
Currently,path0istheonlysupportedlatencypath.
Theminimumpayloadratemustbelessthanorequaltothemaximumpayloadratefora
givenpathanddirection.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0MinPayloadRate
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.31

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

6TANV57CLI-35A

2-2655

Total Access/NetVanta Carrier CLI Dictionary

Command ID
20561

2-2656

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path type downstream <0-1> [fast|interleave|nochannel]


Usethelatencypathtypedownstream<03>[fast|interleave|nochannel]commandto
configurethepathtypefromtheVTUCtotheVTURforthespecifiedpath.

Syntax Description
fast

Settofast

interleave

Settointerleave

nochannel

Disablechannel

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathtypedownstream<01>
[fast|interleave|nochannel]command.
(config-vdsl 1/19/1)#latency-path type downstream 0 interleave
VDSL [1/19/1] Latency Path 0 Downstream Type = Interleave
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhensinglechanneloperationis
used.
Currently,path0istheonlysupportedlatencypath.
Usethefastoptiontoconfigurethechannelforframingparameters:R=0,S<=1,D=1,delay
bound<1millisecond.
Usetheinterleaveoptiontoconfigurethechannelforframingparametersthatsatisfythe
otherlatencypathrestrictionsselected.
Usethenochanneloptiontodisabletheuseofalatencypath.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfDsLp0Type
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.55

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-2657

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
78138

2-2658

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

latency-path type upstream <0-1> [fast|interleave|no-channel]


Usethelatencypathtypeupstream<03>[fast|interleave|nochannel]commandtoconfigure
thepathtypefromtheVTURtotheVTUCforthespecifiedpath.

Syntax Description
fast

Settofast

interleave

Settointerleave

nochannel

Disablechannel

Usage Examples
Thefollowingisanexampleofhowtousethelatencypathtypeupstream<01>[fast|inter
leave|nochannel]command.
(config-vdsl 1/19/1)#latency-path type upstream 0 interleave
VDSL [1/19/1] Latency Path 0 Upstream Type = Interleave
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthepathis0to3.Input0forthepathwhensinglechanneloperationis
used.
Currently,path0istheonlysupportedlatencypath.
Usethefastoptiontoconfigurethechannelforframingparameters:R=0,S<=1,D=1,delay
bound<1millisecond.
Usetheinterleaveoptiontoconfigurethechannelforframingparametersthatsatisfythe
otherlatencypathrestrictionsselected.
Usethenochanneloptiontodisabletheuseofalatencypath.
Thedefaultpathtypeisinterleave.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsLp0Type
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.54

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-2659

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
78142

2-2660

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

power-back-off upstream [a|auto|b|c|custom|d|disable|e|f]


Usethepowerbackoffupstream[a|auto|b|c|custom|d|e|f]commandtoconfigurethe
VDSLtransmitpowercontrolinthedirectionfromtheVTURtotheVTUC.Transmitpower
controlisintendedtoreducepotentialcrosstalkgeneratedbyaVDSLphysicalinterfacein
specificdeploymentsituations.Inparticular,shortloopconditionsnexttolongloopcondi
tionscanseverelyimpactperformanceandstability.ThepredefinedparametersforAandF
NoiseenvironmentlevelsarespecifiedfordeploymentregionA(NorthAmerica)inANSI
T1.4242004.ThepredefinedparametersforAFNoiseenvironmentlevelsarespecifiedfor
otherdeploymentregionsinETSITS1012701.Theoffselectiondisablesallupstreampower
powercontrols.Usethenoformofthiscommandtoapplythedefaultcondition.

Syntax Description
a

SetpowerbackofftomodeA

auto

Setpowerbackofftomodeauto

SetpowerbackofftomodeB

SetpowerbackofftomodeC

custom

Setpowerbackofftomodecustom

SetpowerbackofftomodeD

disable

Disablepowerbackoff

SetpowerbackofftomodeE

SetpowerbackofftomodeF

Usage Examples
Thefollowingisanexampleofhowtousethepowerbackoffupstream
[a|auto|b|c|custom|d|disable|e|f]command.
(config-vdsl 1/19/1)#power-back-off upstream f
VDSL [1/19/1] Upstream Power Back Off = F
(config-vdsl 1/19/1)#

Functional Notes
UsetheautooptiontoenabletheVDSLinterfacetoautomaticallydeterminethebestnoise
environmentselectionbasedonpastperformanceandcurrentdeploymentselections.
UsethecustomoptiontoconfiguretheinterfacetousethecustomVDSL2UPBOparameters
preprovisioned.
ThedefaultisnoiseenvironmentF.
Automticandcustomoptionsarenotcurrentlyallowed.
FordeploymentregionA,BEnoiseenvironmentsarethesameasFsincethesearenot
currentlydefined.
SNMPcrossreference:

6TANV57CLI-35A

2-2661

Total Access/NetVanta Carrier CLI Dictionary

ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfUsPboSetting
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.17

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
19769

2-2662

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

rate-adaption downstream [fixed|startup]


Syntax Description
fixed

Setratemodetofixed

startup

Setratemodetoadaptatstartup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
93447

6TANV57CLI-35A

2-2663

Total Access/NetVanta Carrier CLI Dictionary

rate-adaption upstream [fixed|startup]


Syntax Description
fixed

Setratemodetofixed

startup

Setratemodetoadaptatstartup

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
93451

2-2664

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

service-mode [adsl2|adsl2+|adsl2+m|adsl2-multimode|gdmt|vdsl2]
UsetheservicemodecommandtoselectasinglespecificDMTmodeofoperationthatis
allowed.ThesemodesarethemoretypicalDMTstandardsutilized.

Syntax Description
adsl2

SetservicemodetoADSL2

adsl2+

SetservicemodetoADSL2+

adsl2+m

SetservicemodetoADSL2+M

adsl2multimode

SetservicemodetoADSL2MULTIMODE

gdmt

SetservicemodetoG.DMT

vdsl2

SetservicemodetoVDSL2

Usage Examples
Thefollowingisanexampleofhowtousetheservicemode[adsl2|adsl2+|adsl2+m|adsl2
multimode|gdmt|vdsl2]command.
(config-vdsl 1/19/1)#service-mode vdsl2
VDSL [1/19/1] Service Mode = VDSL2
(config-vdsl 1/19/1)#

Functional Notes
Servicemodesnotcurrentlysupportedbythesystemwillerrorwithaninvalidselection
response.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfServiceMode
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.10
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):adGenVdsl2LineConfProfileTable
adGenVdsl2ConfMultiModeDmtTse
OID:1.3.6.1.4.1.664.5.65.1.1.1.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

6TANV57CLI-35A

2-2665

Total Access/NetVanta Carrier CLI Dictionary

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20448

2-2666

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

shutdown [maintenance|unassigned]
UsetheshutdowncommandtoadministrativelydisabletheselectedVDSLinterface(nodata
ispassedthrough)andplaceitinalowpowerdisabledstate.Usethenoshutdowncommand
toenabletheinterfaceandallowittopassdataandactivelyprovidealarms.Usethe
shutdownmaintenancecommandtoenabletheinterfacebutinhibitalarmreporting(local
statusonlyofalarmconditionsarestillmaintained).

Syntax Description
shutdown

Disablethisinterface(OutofServiceUnassigned)

maintenance

Enablethisinterfacewithalarmsuppression(OutofService
Maintenance)

unassigned

Disablethisinterface(OutofServiceUnassigned)

Usage Examples
Thefollowingisanexampleofhowtousetheshutdown[maintenance|unassigned]
command.
! To disable the interface:
(config-vdsl 1/19/1)#shutdown
(config-vdsl 1/19/1)#
! To disable the interface:
(config-vdsl 1/19/1)#shutdown unassigned
(config-vdsl 1/19/1)#
! To enable the interface:
(config-vdsl 1/19/1)#no shutdown
(config-vdsl 1/19/1)#
! To enable the interface but inhibit alarms:
(config-vdsl 1/19/1)#shutdown maintenance
(config-vdsl 1/19/1)#

Functional Notes
SNMPcrossreference:
IFMIB(rfc2863.mib)ifXTableifAdminStatus
OID:1.3.6.1.2.1.2.2.1.7

Local Security Permissions


Admin,TechSupport

6TANV57CLI-35A

2-2667

Total Access/NetVanta Carrier CLI Dictionary

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
78695

2-2668

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds es downstream 15-minute <0-900>


Usethethresholdsesdownstream15minute<0900>commandtoconfiguretheerrored
seconds(ES)thresholdinthecurrent15minuteintervaltotriggeradownstream(VTUR)
alarm.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold es downstream 15-minute 0
VDSL [1/19/1] Downstream ES seconds threshold = 0 sec

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinEs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.14

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20598

6TANV57CLI-35A

2-2669

Total Access/NetVanta Carrier CLI Dictionary

thresholds es upstream 15-minute <0-900>


Usethethresholdsesupstream15minute<0900>commandtoconfiguretheerroredseconds
(ES)thresholdinthecurrent15minuteintervaltotriggeraupstream(VTUC)alarm.Setthe
thresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsesupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold es upstream 15-minute 0
VDSL [1/19/1] Upstream ES seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinEs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.7

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20600

2-2670

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds lof downstream 15-minute <0-900>


Usethethresholdslofdownstream15minute<0900>commandtoconfigurethelossofframe
(LOF)secondsthresholdinthecurrent15minuteintervaltotriggeradownstream(VTUR)
alarm.ALOFfailureisdeclaredafter2.5+/0.5secondsofcontinuouserroredframing
condition.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslofdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof downstream 15-minute 0
VDSL [1/19/1] Downstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevaildrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceandunassignedadministration
modes.Thresholdalarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinLofs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20587

6TANV57CLI-35A

2-2671

Total Access/NetVanta Carrier CLI Dictionary

thresholds lof upstream 15-minute <0-900>


Usethethresholdslofupstream15minute<0900>commandtoconfigurethelossofframe
(LOF)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream(VTUC)
alarm.ALOFfailureisdeclaredafter2.5+/0.5secondsofcontinuouserroredframing
condition.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslofupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof upstream 15-minute 0
VDSL [1/19/1] Upstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinLofs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20589

2-2672

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds lol upstream 15-minute <0-900>


Usethethresholdslolupstream15minute<0900>commandtoconfigurethelossoflink
(LOL)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream(VTUC)
alarm.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslolupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lol upstream 15-minute 0
VDSL [1/19/1] Upstream LOL seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinLols
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.5

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20604

6TANV57CLI-35A

2-2673

Total Access/NetVanta Carrier CLI Dictionary

thresholds los downstream 15-minute <0-900>


Usethethresholdslosdownstream15minute<0900>commandtoconfigurethelossof
signal(LOS)secondsthresholdinthecurrent15minuteintervaltotriggeradownstream
(VTUR)alarm.ALOSfailureisdeclaredafter2.5secondsofcontinuouspresenceofthe
correspondingdefectandclearedafter10secondsofabsenceofthedefect.Setthethresholdto
0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslosdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold los downstream 15-minute 0
VDSL [1/19/1] Downstream LOSS seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinLoss
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.12

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20593

2-2674

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds los upstream 15-minute <0-900>


Usethethresholdslosupstream15minute<0900>commandtoconfigurethelossofsignal
(LOS)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream(VTUC)
alarm.ALOSfailureisdeclaredafter2.5secondsofcontinuouspresenceofthecorresponding
defectandclearedafter10secondsofabsenceofthedefect.Setthethresholdto0orusetheno
formofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslosupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold los upstream 15-minute 0
VDSL [1/19/1] Upstream LOSS seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinLoss
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.4

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
20595

6TANV57CLI-35A

2-2675

Total Access/NetVanta Carrier CLI Dictionary

thresholds lprs downstream 15-minute <0-900>


Usethethresholdslprsdownstream15minute<0900>commandtoconfiguretheLossof
PowerSeconds(LPRS)secondsthresholdinthecurrent15minuteintervaltotriggera
downstream(VTUR)alarm.ALPRSfailureisdeclaredafter2.5+/0.5secondsofcontinuous
erroredframingcondition.Setthethresholdto0orusethenoformofthiscommandto
disablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslprsdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof downstream 15-minute 0
VDSL [1/19/1] Downstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevaildrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceandunassignedadministration
modes.Thresholdalarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinLprs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104684

2-2676

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds lprs upstream 15-minute <0-900>


Usethethresholdslprsupstream15minute<0900>commandtoconfiguretheLossofPower
Seconds(LPRS)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream
(VTUC)alarm.ALPRSfailureisdeclaredafter2.5+/0.5secondsofcontinuouserrored
framingcondition.Setthethresholdto0orusethenoformofthiscommandtodisablethe
alarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdslprsupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof upstream 15-minute 0
VDSL [1/19/1] Upstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinLprs
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104687

6TANV57CLI-35A

2-2677

Total Access/NetVanta Carrier CLI Dictionary

thresholds ses downstream 15-minute <0-900>


Usethethresholdssesdownstream15minute<0900>commandtoconfiguretheSeverely
ErroredSeconds(SES)secondsthresholdinthecurrent15minuteintervaltotriggera
downstream(VTUR)alarm.ASESfailureisdeclaredafter2.5+/0.5secondsofcontinuous
erroredframingcondition.Setthethresholdto0orusethenoformofthiscommandto
disablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof downstream 15-minute 0
VDSL [1/19/1] Downstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevaildrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceandunassignedadministration
modes.Thresholdalarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinSes
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104691

2-2678

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds ses upstream 15-minute <0-900>


Usethethresholdssesupstream15minute<0900>commandtoconfiguretheSeverely
ErroredSeconds(SES)secondsthresholdinthecurrent15minuteintervaltotriggera
upstream(VTUC)alarm.ASESfailureisdeclaredafter2.5+/0.5secondsofcontinuous
erroredframingcondition.Setthethresholdto0orusethenoformofthiscommandto
disablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssesupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof upstream 15-minute 0
VDSL [1/19/1] Upstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinSes
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104694

6TANV57CLI-35A

2-2679

Total Access/NetVanta Carrier CLI Dictionary

thresholds snr downstream <0-99>


Usethethresholdssnrdownstream15minute<0900>commandtoconfiguretheSignalto
NoiseRatio(SNR)secondsthresholdinthecurrent15minuteintervaltotriggera
downstream(VTUR)alarm.ASNRfailureisdeclaredafter2.5+/0.5secondsofcontinuous
erroredframingcondition.Setthethresholdto0orusethenoformofthiscommandto
disablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssnrdownstream<099>command.
(config-vdsl 1/19/1)#threshold lof downstream 15-minute 0
VDSL [1/19/1] Downstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevaildrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceandunassignedadministration
modes.Thresholdalarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinSnr
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104705

2-2680

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds snr upstream <0-99>


Usethethresholdssnrupstream15minute<0900>commandtoconfiguretheSignaltoNoise
Ratio(SNR)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream(VTU
C)alarm.ASNRfailureisdeclaredafter2.5+/0.5secondsofcontinuouserroredframing
condition.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdssnrupstream<099>command.
(config-vdsl 1/19/1)#threshold lof upstream 15-minute 0
VDSL [1/19/1] Upstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinSnr
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104708

6TANV57CLI-35A

2-2681

Total Access/NetVanta Carrier CLI Dictionary

thresholds uas downstream 15-minute <0-900>


Usethethresholdsuasdownstream15minute<0900>commandtoconfiguretheUnavailable
Second(UAS)secondsthresholdinthecurrent15minuteintervaltotriggeradownstream
(VTUR)alarm.AUASfailureisdeclaredafter2.5+/0.5secondsofcontinuouserrored
framingcondition.Setthethresholdto0orusethenoformofthiscommandtodisablethe
alarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasdownstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof downstream 15-minute 0
VDSL [1/19/1] Downstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevaildrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceandunassignedadministration
modes.Thresholdalarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VturThresh15MinUas
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.11

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104698

2-2682

6TANV57CLI-35A

Section 2, Commands - VDSL Interface Configuration Command Set

thresholds uas upstream 15-minute <0-900>


Usethethresholdsuasupstream15minute<0900>commandtoconfiguretheUnavailable
Second(UAS)secondsthresholdinthecurrent15minuteintervaltotriggeraupstream(VTU
C)alarm.AUASfailureisdeclaredafter2.5+/0.5secondsofcontinuouserroredframing
condition.Setthethresholdto0orusethenoformofthiscommandtodisablethealarm.

Usage Examples
Thefollowingisanexampleofhowtousethethresholdsuasupstream15minute<0900>
command.
(config-vdsl 1/19/1)#threshold lof upstream 15-minute 0
VDSL [1/19/1] Upstream LOF seconds threshold = 0 sec
(config-vdsl 1/19/1)#

Functional Notes
Thevalidrangeforthethresholdis0to900seconds.
Reportingofalarmconditionsissuppressedinmaintenanceadministrationmodes.Threshold
alarmsareofminor/informationalseverity.
SNMPcrossreference:
ADTRANGENVDSL2LINEMIB(adGenVdsl2.mi2):
adGenVdsl2LineAlarmConfProfileTableadGenVdsl2VtucThresh15MinUas
OID:1.3.6.1.4.1.664.5.65.1.1.2.1.3

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
VDSL2Combo24PAM(1187120L1),VDSL2AM(1187121L1),VDSL2SplitterAM
(1187125L1)

Command ID
104701

6TANV57CLI-35A

2-2683

Total Access/NetVanta Carrier CLI Dictionary

Voice Class of Service Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#voice class-of-service WORD
ChassisId(config-cos name)#

ThefollowingisalistofcommandsavailableintheVoiceClassofServiceConfiguration
CommandSet.
callprivilege[900number|all|internal|international|local|national|operator
assisted|specifycarrier|tollfree|user1|user2|user3]
exit

2-2684

6TANV57CLI-35A

Section 2, Commands - Voice Class of Service Configuration Command Set

call-privilege [900number|all|internal|international|local|national|operatorassisted|specify-carrier|toll-free|user1|user2|user3]
Syntax Description
900number

Permit900calls

all

Permitallcalls

internal

Permitinternalcalls

international

Permitinternationalcalls

local

Permitlocalcalls

national

Permitlongdistancecalls

operatorassisted

Permitoperatorassistedcalls

specifycarrier

Permitcallsthatspecifycarrier

tollfree

Permittollfreecalls

user1

Permitcallsthatmatchthe1stuserdefinedtemplate

user2

Permitcallsthatmatchthe2nduserdefinedtemplate

user3

Permitcallsthatmatchthe3rduserdefinedtemplate

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96118

6TANV57CLI-35A

2-2685

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
103112

2-2686

6TANV57CLI-35A

Section 2, Commands - Voice User Configuration Command Set

Voice User Configuration Command Set


ChassisId>enable
ChassisId#configure terminal
ChassisId(config)#voice user NUMBER:20
ChassisId(config-user name)#

ThefollowingisalistofcommandsavailableintheVoiceUserConfigurationCommandSet.
connectfxs<shelf/slot/port>
cosWORD
exit
sipidentityWORD<Txx>
sipidentityWORD<Txx>register
sipidentityWORD<Txx>registerauthnameWORDpasswordWORD

6TANV57CLI-35A

2-2687

Total Access/NetVanta Carrier CLI Dictionary

connect fxs <shelf/slot/port>


Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96279

2-2688

6TANV57CLI-35A

Section 2, Commands - Voice User Configuration Command Set

cos WORD
Local Security Permissions
Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
111773

6TANV57CLI-35A

2-2689

Total Access/NetVanta Carrier CLI Dictionary

exit
Usetheexitcommandtoexitthecurrentmode.InBasicmodeandEnablemode,usethe
exitcommandtocloseoutthecurrentsession.

Local Security Permissions


ReadOnly,Test,ReadWrite,Admin,TechSupport

TACACS+ Levels
Level0

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
103114

2-2690

6TANV57CLI-35A

Section 2, Commands - Voice User Configuration Command Set

sip-identity WORD <Txx>


Syntax Description
WORD

EntertheidentityofthisstationforSIPtrunkuse

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96286

6TANV57CLI-35A

2-2691

Total Access/NetVanta Carrier CLI Dictionary

sip-identity WORD <Txx> register


Syntax Description
WORD

EntertheidentityofthisstationforSIPtrunkuse

<Txx>

Trunkidentifier

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96287

2-2692

6TANV57CLI-35A

Section 2, Commands - Voice User Configuration Command Set

sip-identity WORD <Txx> register auth-name WORD


password WORD
Syntax Description
WORD

EntertheidentityofthisstationforSIPtrunkuse

<Txx>

Trunkidentifier

WORD

Name

Local Security Permissions


Admin,TechSupport

TACACS+ Levels
Level15

Supported Products
ComboAM(1187100L1),ComboAM(1187100L2),RPOTSAM(1187150L1),VDSL2Combo
24PAM(1187120L1)

Command ID
96291

6TANV57CLI-35A

2-2693

ADTRAN CUSTOMER CARE


From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY
1.800.827.0807

reference guide

Carrier Networks Division


901 Explorer Blvd.
Huntsville, AL 35806
U.S.A.
http://www.adtran.com

Anda mungkin juga menyukai