Reduce the size of your


enclosures and, at the
same time, increase
machine reliability...
with these new Zelio Relays
Electromechanical relays RSL
Only 6 mm wide, thus saving considerable space
in your enclosures

6 mm wide

Solid-state relays SSR


Enhanced service life provided by electronic technology
Enhanced service life

Contents
Introduction

Save Space with Zelio Relay RSL .................................................................................................... 4-5


Choose long life and silent operation with Zelio Relay SSR ................................................. 6-7
Electromechanical and solid-state relays panorama .................................................................... 8-9

Technical characteristics

Zelio
Zelio
Zelio
Zelio

Relay RSL ................................................................................................................................. 12-17


Relay RSB, RXM, RUM, RPM ............................................................................................ 18-49
Relay ABR, ABS .................................................................................................................... 54-73
Relay SSR .............................................................................................................................. 74-81

Make the most of your energy SM


3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Save space

with Zelio Relay RSL


Only 6 mm wide
reduces the size of your enclosure

> A solution for


any application

A versatile offer
> An offer with maximum flexibility, comprising:
complete products: a single reference for a relay
mounted on a socket,
> Wide choice of sockets available covering a range
of voltages from 12 to 230 V.
select the relay and associated socket
according to your application.

An offer that meets the most


demanding standards
Conformity with the European RoHS
(Restriction of Hazardous Substances) directive.
Conformity to international standards
IEC/EN 61810-1, UL508, CSA C22.2 N14, GOST.

100% RoHS
Schneider Electric commits itself to
reducing the environmental impact
of its products
4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

> Increased reliability


in operation

Added protection in the socket


Built-in protection from transients
and reverse polarity voltages.

LED indicator
Power on and relay status indication.

Standard 1 C/O relays


For general purpose load requirements.

6A

Up to
switching

> Simple installation


and maintenance

Simple maintenance of relay in socket


Using locking/unlocking lever.

Simple wiring

Bus jumpers available as accessories.

Simple mounting on DIN rail


2 connection choices

Suitable for the majority of your applications.

Screw connector

Spring terminal
5

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Choose long life and


silent operation with

Zelio SSR Relays


> Optimized heat exchange
The new solid-state relays SSR with SCR (Semiconductor
Controlled Rectifier) outputs offer you two alternatives:

SSRD range

Integrated heat sink to provide factory tested heat exchange,


that easily mounts by clipping directly onto DIN rail. Can also
be panel mounted.

SSRP range

Panel mounted, either by itself or combined with


a heat sink for applications requiring considerable heat exchange.

SS

RA
H1

AS
SE
0812 MB
LE
D IN

ME
XIC
O

SSRP relay mounted on heat sink with


thermal transfer pad

6
4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

> Distinctive indication


A green LED on the front face of the products provides instant
indication of the presence of input voltage.

> High performance


High breaking capacities

From 10 to 125 A for relays SSRP


From 10 to 45 A for relays SSRD

Wide supply voltage range

Enhanced
service life
due to electronic relay
technology

From 3 to 32 VDC and 90 to 280 VAC

Outputs suited to applications

From 24 to 280 VAC and 48 to 530/660 VAC

Only 22.5 mm and up to 45.5 mm wide

Complete
silence when
switching

Enhanced service life

providing suitability for


building and hospital
applications

Space Saving SSRD series

Reduced preventive maintenance. SSR relays have


little to no maintenance required once applied correctly.

Silence of electronic technology


Complete silence when switching

Vibration resistant

Even in the event of excessive vibration, the relay


will not change state

High switching
frequency
particularly on packaging
and textile machines

> Conformity to

international standards

100%
RoHS

Schneider Electric commits


itself to reducing the environmental
impact of its products

7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Panorama Zelio Relays


Electromechanical relays

Contact configuration
Current

1 C/O

1 or 2 C/O

1 or 2 C/O

2, 3 or 4 C/O

6A

8-12-16 A

5-12 A

6-10-12 A

DIN rail

DIN rail or panel

DIN rail

Mounting
Catalog numbers
Pages

RSL

RSB

ABR

RXM

12 to 17

20 to 23

54 to 73

24 to 31

Electromechanical relay advantages


Wide number of contacts (up to 4)
Easy installation and maintenance
Socket compatible plug in relays
Flag indicator to show contact status
Lockable test button for checking circuit during build
Magnetically isolated
Coil voltage LED indicator

8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Electromechanical relays

Solid-state relays

2, 3 or 4 C/O

1, 2, 3 or 4 C/O

2 C/O or 2 N/O

1 N/O

1 N/O

1 N/O

10 A

15 A

30 A

3A

10 ...45 A

10 ...125 A

DIN rail or panel


RUM

RPM

32 to 41

42 to 49

RPF
50 to 53

DIN rail

DIN rail or panel

Panel

ABS

SSRD

SSRP

54 to 73

74 to 81

74 to 81

Solid-state relay (SSR) advantages


Enhanced service life
Wide supply voltage range and high breaking current
(up to 125 A), suited to packaging and textile machines
Input power indicator
Completely silent switching, suitable for building and
hospital applications
Vibration resistant

9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Technical information

Zelio Plug-In Relays

Relays

Contact types

Circuit symbol

2
3

Contact
configuration
Make contact
(Normally Open)

EU
USA
nomenclature nomenclature
N/O
SPST-NO
DPST-NO
nPST-NO (1)

Break contact
(Normally Closed)

N/C

SPST-NC
DPST-NC
nPST-NC (1)

Changeover Contact

C/O

SPDT
DPDT
nPDT (1)

Utilization categories

4
5
6

Category
AC-1

Type of current
a single-phase
a 3-phase

Applications
Resistive or slightly inductive loads.

AC-3

a 3-phase

Starting and braking of squirrel cage motors; reversing


direction of rotation only after stopping of motor.

AC-4

a 3-phase

Starting of squirrel cage motors, inching. Plugging,


reversing direction of rotation.

DC-1

Resistive or slightly inductive loads (2).

AC-14

a single-phase

Control of electromagnetic loads (<72VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

AC-15

a single-phase

Control of electromagnetic loads (>72VA), auxiliary


control relays, power contactors, electromagnetic
solenoid valves and electromagnets.

DC-13

Control of electromagnetic loads, auxiliary control relays,


power contactors, magnetic solenoid valves and
electromagnets.

Protection categories

7
8

Category
RT 0

Explanation
Condition
Unenclosed relay Relay not provided with a protective case.

RT I

Dust protected
relay

Relay provided with a case which protects its mechanism


from dust.

RT II

Flux-proof relay

RT III

Wash-tight relay

Relay capable of being automatically soldered without


allowing the migration of solder fluxes beyond the
intended areas.
Relay capable of being automatically soldered and then
washed to remove flux residues without risk of ingress of
flux or washing solvents.

RT IV

Sealed relay

Relay provided with a case which has no venting to the


outside atmosphere.

RT V

Hermetically
Sealed relay having an enhanced level of sealing.
sealed relay
(1) n = number of contacts.
(2) The switchable voltage can be doubled, for an equal current, by connecting two contacts in
series.

9
10

10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Technical information
(continued)

Protection modules

Whenever an inductive load is de-energized (coil of a relay or of a contactor), an


overvoltage appears at its terminals. This voltage peak can reach several thousand
volts and a frequency of several MHz.
It is likely to disturb the operation of automation systems which contain electronic
devices.
Protection modules are used to reduce the voltage peak on de-energization and
they therefore limit the energy of interference signals to a level that will not disturb
surrounding coils and electronic devices.
These modules are used to avoid:
v electromagnetic compatibility problems
v the deterioration of contact materials
v the destruction of insulation due to overvoltage
v the destruction of electronic components

U
Supply voltage

Energy released

b Considerations
v increase in relay drop-out time (up to 3 to 4 times the usual time)
v no polarity protection
v de-energization of the relay

Coil voltage with diode protection module (conly)

Protection module with varistor


b Advantages
v can be used with a and c supply
v voltage peak limited to about 2Un
v little effect on relay drop-out time

Break

b Considerations
v no modification of coils own oscillating frequency
v limitation of switching frequency

Limitation of voltage
peaks

Energy
released

6
7

Coil voltage with varistor protection module (aandc)

Protection module with RC circuit


b Advantages
v coil oscillating frequency reduced to about 150Hz
v voltage peak limited to 3 Un
v little effect on relay drop-out time

Break

b Considerations
v no protection for low voltages

U2

U1

S2 (with RC)

2
3

Diode protection module (with or without LED)


b Advantages
v accumulation of energy allowing current flow in the same direction
v absence of any voltage peaks at the coil terminals
v low cost

Break

S1

Coil voltage with RC circuit protection module (aonly)


S1 = S2 = Energy released

10

11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Introduction

RSL slim interface relays

Introduction

RSL slim interface relays offers compact size in a modular design: their slim width (6
mm) saves valuable space when mounting on a DIN rail at the back of an enclosure.

RSL relays are available in two versions:


bb Pre-assembled range: a single catalog number for a standard relay mounted on
a socket.
vv The socket includes a built-in protection circuit (against transients and reverse
polarity voltages) and an LED indicator as standard.
vv Wire connection options: screw connectors and spring terminals.
vv This pre-assembled solution covers a wide range of operating voltages from 12 to
230 V.
bb Individual relays and sockets:
vv The relay and the socket can be provided separately according to the
requirements of the application.
vv Simple maintenance: an RSL slim relay can be replaced without any need to
disconnect the socket wiring.

2
3
1

Description

RSL slim interface relays, pre-assembled


1 6 A standard relay with 1 C/O contact.
2 Retention lever for easy removal of the relay from its socket.
3 Sockets: wire connection by screw connector or spring terminals.
4 All sockets have a built-in protection circuit and an LED indicator.

5
6
RSL slim interface relay

1 Five flat, reinforced PCB pins.


1
1

2
3

Sockets for RSL slim interface relays


1 Five female contacts for the relay pins.
2 Retention lever which accepts optional ID tags.
3 Wire connection by screw connector or spring terminals.
4 Built-in protection circuit and LED indicator.
5 Locating slot for mounting on DIN rail.

9
10
5
Introduction:
page 12

Characteristics:
page 13

Product selector:
page 16

Dimensions, Wiring diagrams:


page 17

12
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics

Zelio Plug-In Relays


RSL slim interface relays

General characteristics

Conforming to standards

IEC 61810-1, UL508, CSA C22-2 No. 14

Product certifications

UL E173076, UL E172326, CSA 240278, CSA 247510, GOST

Ambient air temperature


around the device

Vibration resistance
conforming to
IEC/EN 60068-2-6

Storage

- 40 + 85

Operation

- 40 + 55

In operation

10 gn

Not operating

5 gn

Degree of protection

Conforming to IEC/EN 60529

IP 40 (Relays)
IP 20 (Sockets)

Shock resistance
conforming to
IEC/EN 60068-2-27

Opening

10 gn

Closing

5 gn

Protection category

RT III

Mounting position

Any

Insulation characteristics

Rated insulation voltage (Ui)

250 (IEC)

Rated impulse withstand voltage (Uimp)

kV

Dielectric strength
(rms voltage)

Between coil and contact

aV

4000

Between contacts

aV

1000

1
2
3
4
5
6
7
8
9
10

13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics (continued)

RSL slim interface relays

Contact characteristics

1
2

Relay type

1 C/O standard

Contact materials

AgSnO2

Conventional thermal
current (Ith)

For ambient
temperature y 55 C

Rated operational current


in utilization categories
AC-1 and DC-1

Conforming to IEC

Switching current
Switching voltage

N/C

N/O

Conforming to UL

Minimum

mA

100

Rated

aV

250

Maximum

a 400, c 300

Minimum

12

Nominal load (resistive)


Switching capacity

RSL1ABppp

Number and type of contacts

A / a V 6 / 250V (at 50mW)


Maximum

VA

c
Minimum

1500

18150 (depending on the voltage)

mW

120

Maximum operating rate


In operating cycles / hour

No-load

72000

Under load

360

Mechanical durability

In millions of operating cycles

u 10

Electrical durability
Resistive load
In millions of operating cycles
Inductive load

See curves below


0.05 (N/O contact: a250 V, 3 A, AC-15)
Maximum switching capacity on c load

Voltage c

300

200
100

Resistive load

50
40
30
20

10
0,1 0,2

Coil characteristics

8
9

Average consumption

Drop-out voltage threshold


Operating time
(response time)

10 20
Current c

0.17
u 0.05 Uc

ms

12 max

Between coil de-energization and


making of the NC contact

ms

5 max

12

24

48

60

JD

BD

ED

ND

848

3390

10 600

20 500

Min.

8.4

16.8

33.6

42

Max.

16.8

33.6

67.2

84

Relay control voltage codes


Average resistance at 23 C 10%
Operating voltage limits

10
Introduction:
page 12

Between coil energization and


making of the NO contact

Control circuit voltage Uc


DC supply

0,5

Characteristics:
page 13

Product selector:
page 16

Dimensions, Wiring diagrams:


page 17

14
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Zelio Plug-In Relays


RSL slim interface relays

Socket characteristics
Socket type

RSLZVpp

RSLZRpp

Relay types used

RSL1pppp

RSL1pppp

Conforming to standards

IEC 61984, UL508, CSA C22-2 No. 14

Product certifications

UL, CSA, GOST

Contact terminal arrangement

Separate

Separate

Wire connection method

Screw connector

Spring terminals

mm

6.2

6.2

Conventional thermal current (Ith)

Maximum operating voltage

aV

300

Width

1
2

Electrical characteristics

Insulation characteristics
Between adjacent output contacts

Vrms

2500

Between input and output contacts

Vrms

2500

Between contacts and DIN rail

Vrms

2500

General characteristics
Ambient air temperature
around the device

Operation

- 40+ 70 (-40 to +55 for U > 80 V)

Storage

- 40+ 85

Degree of protection

Conforming to IEC/EN 60529

Connection

Solid wire without 1 conductor


cable end

mm

0.22.5

0.21.5

AWG

2414

2416

Flexible wire
with cable end

mm

0.22.5

0.21.5

AWG

24 14

2416

1 conductor

IP 20

Screw size

mm

M 2.5

Maximum tightening torque

Nm

0.5

10 N40 N (0.2 1.5 mm)

Mounting

On 35 mm DIN rail

Mounting on DIN rail

By plastic compression spring

Terminal reference

IEC

LED indicator

Yes (built-in)

Added protection in circuit

Yes (built-in)

Wire connection method

Screw connector

6
Spring terminal

7
Sockets operating voltage

Operating voltage

Tolerance

V
Socket type

RSLZVA1, RSLZRA1

Control circuit voltage (relay)


V

c/a 12

+ 20% / - 5%

c 12

c/a 24

+ 20% / - 10%

c 24

c/a 48

+ 20% / - 10%

c 48

c/a 60

+ 20% / - 10%

c 60

RSLZVA3, RSLZRA3

c/a 110

+ 15% / - 20%

c 60

RSLZVA4, RSLZRA4

c/a 230

+ 15% / - 20%

c 60

RSLZVA2, RSLZRA2

8
9
10

15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RSL slim interface relays

Slim interface relays, pre-assembled

Standard relays mounted on socket equipped with LED and protection circuit

Sold in lots of 10

1 C/O contact - Thermal current (Ith) 6A


Operating voltage
(input voltage)

Socket type
Catalog Number

2
3

RSL1PVpp

RSL1PRpp

Replacement Relay

Screw connector

Spring terminal
Weight

Catalog Number

Weight

kg

Catalog Number

kg

c/a 12

RSL1PVJU

0.031

RSL1PRJU

0.029

RSL1AB4JD

c/a 24

RSL1PVBU

0.031

RSL1PRBU

0.029

RSL1AB4BD

c/a 48

RSL1PVEU

0.031

RSL1PREU

0.029

RSL1AB4ED

c/a 110

RSL1PVFU

0.031

RSL1PRFU

0.029

RSL1AB4ND

c/a 230

RSL1PVPU

0.031

RSL1PRPU

0.029

RSL1AB4ND

Slim interface relays for customer assembly: relay + socket


Relays with flat, reinforced pins (PCB type)
Sold in lots of 10

1 C/O contact - Thermal current (Ith) 6A

Standard
Control circuit voltage (relay coil voltage)

Catalog Number

V
RSL1pppp

Weight
kg

c 12

RSL1AB4JD

0.006

c 24

RSL1AB4BD

0.006

c 48

RSL1AB4ED

0.006

c 60

RSL1AB4ND

0.006

Sockets equipped with LED and protection circuit


Sold in lots of 10

Socket type
Operating voltage
(input voltage)

Screw connector
For use with relays

Catalog Number

7
RSLZVAp

Weight
kg

c/a 12 and c/a 24

RSL1AB4JD
RSL1AB4BD

RSLZVA1

0.025

RSLZRA1

0.023

c/a 48 and c/a 60

RSL1AB4ED
RSL1AB4ND

RSLZVA2

0.025

RSLZRA2

0.023

c/a 110

RSL1AB4ND

RSLZVA3

0.025

RSLZRA3

0.023

c/a 230

RSL1AB4ND

RSLZVA4

0.025

RSLZRA4

0.023

RSLZRAp

Description

Catalog Number

kg

Accessories for sockets


RSLZ2

10

Spring terminal
Weight

Compatibility

Catalog
Number

Weight
kg

Clip-in ID tags
(2 sheets of 64 ID tags)

With all sockets

RSLZ5

0.001

Bus jumper
(10 x 20-pole jumper)

With all sockets

RSLZ2

0.003

Butterfly isolator
(10 isolators)

With all sockets

RSLZ3

0.001

Characteristics:
page 13

Product selector:
page 16

RSLZ3

Introduction:
page 12

Dimensions, Wiring diagrams:


page 17

16
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions,
Wiring diagrams

RSL slim interface relays

Slim interface relays, pre-assembled

RSL1PRpp (spring terminals)

51,5

6,2

101

95

35,3

30,1

RSL1PVpp (screw connector)

6,2

51,5

78,6

6,2

6,2

78,6

Relays

RSL1pppp with flat, reinforced PCB pins

3,50,5

11,34 (1) (1) 1,9

5 max

1 C/O contact

14

28 max

11
12
A1

3,78

15 max

A2

(1): 5.04 mm

Sockets

RSLZRpp (spring terminals)


35,3

30,1

RSLZVpp (screw connector)

101

95

6
7

51,5

6,2

6,2

51,5

78,6

6,2

6,2

78,6

Socket connections

Example of RSLZ2 bus jumper


mounting on sockets

RSLZVpp (screw connector)

RSLZRpp (spring terminals)

12

12

11

11

14

Side view

(1)

14

(3)

(2)
A1
A2

Protection
circuit

14

A1

11

A2

12

Protection
circuit

14

(4)

11
12

A1

A1

A2

A2

10
(1) A1
(2) A2
(3) Bus jumper polarity A1
(4) Bus jumper polarity A2

17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Selection guide

Application

Plug-in relays
Interface relays

Miniature relays

2
3

Number and type of contacts / conventional thermal


current (Ith on N/O contact)

1 C/O / 16 A
1 C/O / 12 A
2 C/O / 8 A

2 C/O / 12 A
3 C/O / 10 A
4 C/O / 6 A
4 C/O / 3 A (low level)

24240 V
6110 V

24240 V
12220 V

Type of pins

Flat, PCB type

Quick-connect

Operational voltage

Up to a 400 V / c 300 V

Up to 250 V

Control circuit voltage

4
5
6

a
c

Durability
(operating cycles)

Electrical, resistive load


Mechanical, no-load

100 000
30 000 000

100 000
10 000 000

Functions

LED
Mechanical indicator
Lockable test button
Low level contacts

Yes (with protection modules)

Yes (depending on version)


Yes
Yes
Yes (depending on version)

Type reference

RSB

RXM

Pages

20

24

Conventional thermal current (Ith)

12A (1)

10 A

12 A (2)

Contact terminal arrangements

Separate

Mixed

Separate

Connection

Box lug connectors

Screw clamp terminals or


box lug connectors

Box lug connectors

Accessories Protection modules


Timer module
Retention clip
Socket ID tag

Yes

Yes
Yes

Yes

Yes
Yes (except RXZ E2M114)
Yes
Yes

Yes

RSZE1SppM

RXZE2Mppp

7
8
9

Mounting adapters for 5 rail


Mounting adapters with fixing lugs
Bus jumper, 2-pole (Ith = 5 A)

10

Associated socket types

Pages

RXZE2Sppp

20
24
24
(1) When using relay RSB1A160pp with socket RSZE1S48M, terminals must be linked.
(2) Except for sockets RXZ E2S11pM: 10 A.

18
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Universal relays

Power relays

1
2

2 C/O / 10 A
3 C/O / 10 A
3 C/O / 3 A (low level)

2 C/O / 10 A
3 C/O / 10 A

1 C/O / 15 A
2 C/O / 15 A
3 C/O / 15 A
4 C/O / 15 A

24230 V
12220 V

12110 V

24230 V
12110 V

Cylindrical

Quick-connect

Quick-connect

Up to 250 V

Up to 250 V

100 000
5 000 000

100 000 (3)


10 000 000

Yes (depending on version)


Yes
Yes
Yes (depending on version)

Yes (depending on version)


Yes
Yes

RUM

RPM

32

42

3
4
5
6
7

12 A
Mixed

16 A
Separate

Box lug connectors

Screw clamp terminals

Yes
Yes
Yes
Yes

Yes

Yes
Yes (for 3 and 4-pole)
Yes (on socket RPZ F1)
Yes
Yes
Yes

RUZCpM

RUZSCpM

32
(3) 100 000 for RPM1 and RPM2; 60 000 for RPM3 and RPM4.

Mixed

RUZSF3M

RPZFp

32

42

9
10

19
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Introduction,
characteristics

RSB interface relays

Introduction of the product range


The RSB interface relay range includes:
1 12 A relays with 1 C/O contact , 16 A relays with 1 C/O contact and 8 A relays with
2 C/O contacts.
2 Sockets with separate contact terminals.
3 Protection modules (diode, diode + LED, RC circuit or varistor + LED).
4 Plastic hold-down ejector clip for all sockets.
5 Clip-in ID tags for all sockets.

Socket description
Sockets with separate contact terminals (1)
1 Box lug connectors.
2 Five or eight female contacts for the relay pins.
3 Mounting hole for panel mounting.
4 Location for protection modules.
5 Locking components for plastic hold-down ejector clip.
6 Locating slot for mounting on DIN rail.

Inputs

Outputs

2
5
3

(1) The inputs and outputs are separated from the relay supply.

Relay supply

General characteristics

6
7
8
9

Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
Conforming to IEC/EN 60068-2-6
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

C (F)
C (F)

Rated insulation voltage (Ui) Conforming to IEC/EN 60947


Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

V
kV
aV
aV
aV

400
3.6 (1.2/50 s)
5000
2500
1000
RSB1A160pp
1 C/O

RSB2A080pp
2 C/O

RSB1A120pp
1 C/O
AgNi
12

16

A
A

12
6

16
8

8
4

mA
V
V
A
A
VA
W
mW

5
a 400, c 300
5
12 / 250a V
12 / 28c V
3000
336
300
72 000
600

16 / 250a V
16 / 28c V
4000
448

8 / 250a V
8 / 28c V
2000
224

Insulation characteristics

Contact characteristics
Relay type
Number and type of contacts
Contact materials
Conventional thermal
current (Ith)
Rated operational current
in utilization categories
AC-1 and DC-1
Switching current
Switching voltage

For ambient
temperature y 40C
Conforming to IEC

N.O.
N.C.

Minimum
Maximum
Minimum

Nominal load (resistive)

10

IEC/EN 61810-1, UL 508, CSA C22-2 n 14


cURus File E173076 CNN NRNT2,; CSA File 215736 Class 321107; CE; RoHS compliant
- 40+ 85 (-40 ... +185)
c - 40+ 85 (-40 ... +185), a - 40...+ 70 (-40 ... +158)
>10gn (10..150 Hz)
IP 40
5 gn
10 gn
RT I
Any

Switching capacity

Maximum

Maximum operating rate


In operating cycles/hour

Minimum
No-load
Under load

Introduction:
page 20

Characteristics:
page 20

a
c

Product selector:
page 22

Dimensions, Wiring diagrams:


page 23

20
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Contact characteristics (continued)

Relay type
Mechanical durability
Electrical durability
In millions of op. cycles

107

A
106

C
B

105

RSB interface relays

RSB 1A120pp
RSB1A160pp
RSB2A080pp
u 30
12 A, 250 Va (u 0.1)
16 A, 250 Va (u 0.07)
8 A, 250 Va (u 0.1)
See curves below
Reduction coefficient for inductive load a
Maximum switching capacity on resistive load
(depending on power factor cos j)
c
Reduction coefficient (A)

Durability (Number of operating cycles)

In millions of operating cycles


Resistive load (p.f.)
Inductive load
Electrical durability of contacts
Resistive load a

Zelio Plug-In Relays

1
0,8

Current c

Characteristics (continued)

0,6
0,5

50

16
12
8
5

2
1

0,4

0,5

104

0,3
0

0,4

0,8 1 1,2

1,6

0,1

0,6

0,4

0,2

10

20 30

50

100

200 300

Voltage c

Switching capacity (kVA)

A RSB2A080pp B RSB1A160pp C RSB1A120pp. Inductive load durability = resistive load durability x reduction coefficient.
Coil characteristics

Average consumption
Drop-out voltage threshold
Operating time
Between coil energization and
(response time)
making of the NO contact

a
c
Between coil de-energization and a
making of the NC contact
c
Control circuit voltage Uc
Relay control voltage codes
d.c. supply
Average resistance at 20 C 10%
Operating
Min.
voltage limits
Max.
Relay control voltage codes
a.c. supply
Average resistance at 20 C 15%
60 Hz
Operating
Min.
50 Hz
voltage limits
60 Hz
Max.
50/60Hz

Socket characteristics

ms
ms
ms
ms
V
W
V
V
W
V
V

Socket type
Relay types used
Contact terminal arrangement
Wire connection method
Product certifications
Product certifications

Electrical characteristics

c 0.45 W, a 0.75 VA
c 0.1 Uc (10% of rated voltage), a 0.15 Uc (15% of rated voltage)
12
9
10
4
6
12
24
48
60
110
120
220
230
RD
JD
BD
ED
ND
FD

90
360
1440
5700
7500
25 200

4.8
9.6
19.2
38.4
48
88

6.6
13.2
26.4
52.8
66
121

B7
E7

F7
M7
P7

400
1550

10 200 35 500 38 500

19.2
38.4

96
176
184

20.4
40.8

102
187
195.5

26.4
57.6

144
264
276

A
Va

12
300

Between adjacent output contacts


Between input and output contacts
Between contacts and DIN rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device
Degree of protection
Connection
box lug connector

C (F)
C (F)

- 25+ 85 (-13... +185)


- 40+ 85 (-40... + 185)
IP 20
0.52.5 mm2 - AWG 20AWG 14
0.51.5 mm2 - AWG 20AWG 16
0.252.5 mm2 - AWG 22AWG 14
0.251 mm2 - AWG 22AWG 17
0.8 / M3 screw
35 mm DIN rail / panel mount
By plastic compression spring
IEC
Yes, plastic
No
All RZM ppp
Available

General characteristics

Operation
Storage
Conforming to IEC/EN 60529
Solid wire without 1 conductor
cable end
2 conductors
Flexible wire with 1 conductor
cable end
2 conductors
Maximum tightening torque / Screw size
Mounting
Mounting on DIN rail
Terminal referencing
Compatibility with the metal hold-down clip
Timer module
Protection module
Clip-in ID tags
Wire connection method
Box lug connector

240

U7
42 500
192
204
288

RSZE1S35M
RSZE1S48M
RSB1A120pp
RSB2A080pp, RSB1A160pp (1)
Separate
Connector
e
cURus File E172326 CCN SWIV2; CSA File 212916 Class 3211 07; CE; RoHS compliant

Conventional thermal current (Ith)


Maximum operating voltage

Insulation characteristics

Nm

5
6
7
8
9
10

(1) When using the relay with socket RSZE1S48M, terminals must be linked. See wiring diagrams on page 23.

21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RSB interface relays

Relays for standard applications


Control
circuit
voltage

1
2
3

RSB 1A120JD + RZM 031FPD


+ RSZ E1S35M

4
5

Number and type of contacts - Thermal current (Ith)


1 C/O - 12 A
1 C/O - 16 A
2 C/O - 8 A
Catalog number (1)
Catalog number (1)
Catalog number (1) Weight

V
c6

10

RSB1A120RD

RSB1A160RD

RSB2A080RD

kg
0.014

c 12

10

RSB1A120JD

RSB1A160JD

RSB2A080JD

0.014

c 24

10

RSB1A120BD

RSB1A160BD

RSB2A080BD

0.014

c 48

10

RSB1A120ED

RSB1A160ED

RSB2A080ED

0.014

c 60

10

RSB1A120ND

RSB1A160ND

RSB2A080ND

0.014

c 110

10

RSB1A120FD

RSB1A160FD

RSB2A080FD

0.014

a 24

10

RSB1A120B7

RSB1A160B7

RSB2A080B7

0.014

a 48

10

RSB1A120E7

RSB1A160E7

RSB2A080E7

0.014

a 120

10

RSB1A120F7

RSB1A160F7

RSB2A080F7

0.014

a 220

10

RSB1A120M7

RSB1A160M7

RSB2A080M7

0.014

a 230

10

RSB1A120P7

RSB1A160P7

RSB2A080P7

0.014

a 240

10

RSB1A120U7

RSB1A160U7

RSB2A080U7

0.014

Connection

Relay type

Catalog number

Box lug
connectors

RSB1A120pp
RSB1A160pp (2)
RSB2A080pp

Sold in
lots of
10
10

RSZE1S35M
RSZE1S48M

Weight
kg
0.060
0.050

For
use with

Voltage

Sold in
lots of

Catalog number

Weight

V
c 6230

10

RZM040W

kg
0.003

Sockets 12 A, a 300 V
RSB 1A160BD + RSZ E1S48M

Contact terminal
arrangement
Separate

Protection modules

Description

7
8

Sold in
lots of

Diode

All sockets

RC circuit

All sockets

a 2460
a 110240

10
10

RZM041BN7
RZM041FU7

0.010
0.010

Diode + green LED

All sockets

c 624
c 2460
c 110230

10
10
10

RZM031RB
RZM031BN
RZM031FPD

0.004
0.004
0.004

Varistor + green LED

All sockets

c or a 624
c or a 2460
c or a 110230

10
10
10

RZM021RB
RZM021BN
RZM021FP

0.005
0.005
0.005

Sold in
lots of
10
10

Catalog number

RSB 2A080BD + RSZ E1S48M

Accessories
Description

For
use with
Plastic hold-down ejector clip All sockets
ID tag
All sockets

RSZR215
RSZL300

Weight
kg
0.002
0.001

(1) To order a relay complete with socket (sold in lots of 20): add suffix S to one of the following voltage codes JD, BD, B7, P7 or F7.
Example: RSB2A080BD +RSZE1S48M becomes RSB2A080RBS.
(2) When using the relay with socket RSZE1S48M, terminals must be linked. See wiring diagrams on page 23.
RSZ R215

10
Introduction:
page 20

Characteristics:
page 20

Product selector:
page 22

Dimensions, Wiring diagrams:


page 23

22
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions,
Wiring diagrams

RSB interface relays

Dimensions (mm):
Interface relays
RSB1A120pp

RSB2A080pp, RSB1A160pp

12,5
7,5

12,5
7,5

29

2,5

15

16,5

29

15,7
3,9

2,5

3,5

3,5

15,7
3,9

Sockets
RSZE1S35M

RSZE1S48M

67
61

67
61

(4)

(4)

11

21

11

14

24

14

12

22

12

(1)
78,5

78,5

(1)

(3)

29,4

(2)
A2

(2)
A2

A1

15,5

27,5
34,5

29,4

(3)

A1

15,5

27,5
34,5

50

50
(1) Relays
(2) Protection module
(3) Retention clip
(4) ID tag

Wiring diagrams
Interface relays

14

21

11

22

12

A2

A1

A2

A1

12

24

A2
A1

22

24

14

21

11

22

12

A1

11

21

11

14

12

A2

24

8
9

A2

14

RSB2A080pp

A1

14/24

12/22

A2
A1

RSB1A160pp

11/21

14

12

11

RSB1A120pp

When using relay RSB1A160pp with socket RSZ E1S48M


terminals 11 and 21, 14 and 24, 12 and 22 must be linked

Protection modules
RZM040W

RZM041ppp

RZM031ppp

10

RZM021ppp

A2

A2

A2

A2

+ A1

+ A1

+ A1

+ A1

23
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Introduction

RXM miniature relays

Introduction of the product range

The RXM miniature relay range includes:


1 12 A relays with 2 C/O contacts, 10 A relays with 3 C/O contacts, 6 A relays with
4C/O contacts and 3 A low level relays with 4 C/O contacts. All these relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor).
4 Metal hold-down clip for all sockets.
5 Plastic hold-down ejector clip for all sockets.
6 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify wiring when creating creating a jumper between the coil
terminals.
7 Clip-in ID tags for all the sockets except RXZE2M114.

4
or
5
6

Relay description

8
1
2
3

4
5

7 6

5
6

10

1 Spring return push-to-test button for checking contact operation (green: c,


red: a).
2 Mechanical relay status indicator.
3 Optional removable lock-down door enables continuous engagement of the
contacts for test or maintenance purposes. During operation, this lock-down door
must always be in the closed position.
4 Bipolar LED (depending on version) indicating the relay status.
5 Removable ID tag for relay identification.
6 Four notches for DIN rail mounting adapter or panel mounting adapter with fixing
lugs.
7 Eight, eleven or fourteen quick-connect pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a DIN rail.

Socket description

6
1
Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals or box lug connector.
2 Fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal hold-down clips.
5 Locating slot for mounting on DIN rail.
6 Two or four mounting holes for panel mounting.

4
3
Inputs

Relay coil
terminals

1
Inputs

Outputs

2
4

Sockets with separate contact terminals (2)


1 Connection by screw connector.
2 Eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules.
4 Locking components for plastic and metal hold-down clips.
5 Locating slot for mounting on DIN rail.
6 Two mounting holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page30).

3
(1) The inputs are mixed with the relay coil terminals, with the outputs being located on the
opposite side of the socket.
(2) The inputs and outputs are separated from the relay coil terminals.

10
5 7

Introduction:
page 24

Relay coil terminals


Characteristics :
pages 25 and 26

Product selector:
pages 27 and 28

Dimensions:
pages 29 and 30

Wiring diagrams:
page 31

24
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics

RXM miniature relays

General characteristics

Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

Insulation characteristics

Rated insulation voltage (Ui)


Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8;
CSA; CE; RoHS compliant
- 40 + 85 (-40... +185)
- 40 + 55 (-40... +131)
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
5gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
15 gn
15 gn
RT I
Any

V
kV
aV
aV
aV

250 (IEC), 300 (UL, CSA)


4 (1.2/50 ms)
1550
1550
1500

RXM2ABppp
2 C/O
AgNi
12

C (F)
C (F)

Contact characteristics

Relay type
Number and type of contacts
Contact materials
Conventional thermal
current (Ith)
Rated operational current
in utilization categories
AC-1 and DC-1

For ambient
temperature y 55 C
Conforming to IEC
NO
NC
Conforming to UL
Minimum
Maximum
Minimum

Switching capacity

Maximum

Maximum operating rate


In operating cycles

Minimum
No-load
Under load

Utilization coefficient
Mechanical durability

In millions of operating cycles

12
6
12
10
a/c 250 (IEC)
17
12 / 250a V
12 / 28c V
3000
336
170
18 000
1200
20 %
10

Electrical durability
In millions of operating cycles

Resistive load
Inductive load

0.1
See curves below

Nominal load (resistive)


a
c

107

106

D
C

105
0

10
5
10

6
3
6

10 / 250a V
10 / 28c V
2500
280

6 / 250a V
6 / 28c V
1500
168

B RXM3ABppp

1
0,8
0,6
0,5

2
1
3
3

5
3 / 250a V
3 / 28c V
750
84
15

10
6
3

0,4

0,3

C RXM4ABppp

Maximum switching capacity on resistive load


c

A
D

RXM4GBppp
4 C/O low level
AgAu - bifurcated
3

1
2
Switching capacity (kVA)

A RXM2ABppp

10

Reduction coefficient for inductive load a


(depending on power factor cos j)
Reduction coefficient (A)

Durability (Number of operating cycles)

Electrical durability of contacts


Resistive load a

mA
V
V
A
A
VA
W
mW

RXM4ABppp
4 C/O

Current c

Switching current
Switching voltage

RXM3ABppp
3 C/O

0,1

0,6

0,4

0,2

28 50

100

150

200
250
Voltage c

D RXM4GBppp

Inductive load durability = resistive load durability x reduction coefficient.

10

25
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics (continued)

Coil characteristics

RXM miniature relays

Average consumption

Drop-out voltage threshold

Operating time
(response time)

VA

1.2

0.9
u 0.15 Uc

Between coil energization


and making of the
NO contact

Between coil de-energization


and making of the
NC contact

Control circuit voltage Uc

u 0.1 Uc
ms

20

ms

20

ms

20

ms

20

12

24

48

110

120

125

220

230

240

JD

BD

ED

FD

GD

MD

Relay coil voltage codes


d.c. supply

Average resistance at 20 C 10%

160

650

2600

11 000

11 000

14 000

Operating voltage limits

Min.

9.6

19.2

38.4

88

100

176

Max.

13.2

26.4

52.8

121

B7

E7

Relay coil voltage codes


a.c. supply

7
8
9
10

P7

U7

180

770

4430

15 000

15 500

Operating voltage limits

Min.

19.2

38.4

96

184

192

Max.

26.4

52.8

132

253

264

Socket type

RXZE2S108M RXZE2S111M RXZE2S114M RXZE2M114M

RXZE2M114

Relay types used

RXM2ppppp

RXM2ppppp (1)
RXM4ppppp

RXM3ppppp

RXM4ppppp

Separate
Box lug connectors

Electrical characteristics

Mixed

Conventional thermal current (Ith)


Maximum operating voltage

A
V

12
250 (IEC)

Between adjacent output contacts


Between input and output contacts
Between contacts and DIN rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device

C (F)
C (F)

- 40+ 55 (-40... +131)


- 40+ 85 (-40... +185)
IP 20
0.52.5 mm2 - AWG 20AWG 14

General characteristics

Operation
Storage
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid wire
1 conductor
without
cable end
2 conductors
Flexible wire
1 conductor
with cable end
2 conductors
Maximum tightening torque / Screw size
Mounting
Mounting on DIN rail
Terminal referencing
Bus jumper (Ith: 5 A)
Compatibility with the plastic hold-down ejector clip
Compatibility with the metal hold-down clip
Protection module
Clip-in ID tags
Wire connection method

RXM2ppppp (1)
RXM4ppppp

Screw clamp
terminals
cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant
IEC 61984, e

Product certifications
Conforming to standards

Insulation characteristics

242

Contact terminal arrangement


Wire connection method

138

Average resistance at 20 C 15%

Socket characteristics

F7

10

0.5 1.5 mm2


AWG 20AWG 16

0.51.5 mm2 - AWG 20AWG 16


0.252.5 mm2 - AWG 22AWG 14

Nm

0.251 mm2 - AWG 22AWG 17


1 / M3 screw
35 mm DIN rail / panel mount
By red plastic clip
IEC, NEMA
Yes
Yes
Yes
All RXM040W, RXM041pp, RXM021pp
Yes
Box lug connector

0.251 mm2
AWG 22AWG 17

By metal
compression
spring

By red plastic clip

No

No
Screw clamp
terminals

(1) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.

Introduction:
page 24

Characteristics :
pages 25 and 26

Product selector:
pages 27 and 28

Dimensions:
pages 29 and 30

Wiring diagrams:
page 31

26
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RXM miniature relays

Miniature relays without LED (sold in lots of 10)


Control
circuit
voltage

Number and type of contacts - Thermal current (Ith)


2 C/O - 12 A
Catalog number

RXMpAB1F7

3 C/O - 10 A
Weight

Catalog number

kg

4 C/O - 6 A
Weight

Catalog number

kg

Weight
kg

c 12

RXM2AB1JD

0.037

RXM3AB1JD

0.037

RXM4AB1JD

0.037

c 24

RXM2AB1BD

0.037

RXM3AB1BD

0.037

RXM4AB1BD

0.037

c 48

RXM2AB1ED

0.037

RXM3AB1ED

0.037

RXM4AB1ED

0.037

c 110

RXM2AB1FD

0.037

RXM3AB1FD

0.037

RXM4AB1FD

0.037

c 220

RXM4AB1MD

0.037

a 24

RXM2AB1B7

0.037

RXM3AB1B7

0.037

RXM4AB1B7

0.037

a 48

RXM2AB1E7

0.037

RXM3AB1E7

0.037

RXM4AB1E7

0.037

a 120

RXM2AB1F7

0.037

RXM3AB1F7

0.037

RXM4AB1F7

0.037

a 230

RXM2AB1P7

0.037

RXM3AB1P7

0.037

RXM4AB1P7

0.037

a 240

RXM4AB1U7

0.037

0.037

1
2
3

Miniature relays with LED (sold in lots of 10)

RXMpAB2F7

c 12

RXM2AB2JD

0.037

RXM3AB2JD

0.037

RXM4AB2JD

c 24

RXM2AB2BD

0.037

RXM3AB2BD

0.037

RXM4AB2BD

0.037

c 48

RXM2AB2ED

0.037

RXM3AB2ED

0.037

RXM4AB2ED

0.037

c 110

RXM2AB2FD

0.037

RXM3AB2FD

0.037

RXM4AB2FD

0.037

c 125

RXM4AB2GD

0.037

a 24

RXM2AB2B7

0.037

RXM3AB2B7

0.037

RXM4AB2B7

0.037

a 48

RXM2AB2E7

0.037

RXM3AB2E7

0.037

RXM4AB2E7

0.037

a 120

RXM2AB2F7

0.037

RXM3AB2F7

0.037

RXM4AB2F7

0.037

a 230

RXM2AB2P7

0.037

RXM3AB2P7

0.037

RXM4AB2P7

0.037

Miniature relays with low level contacts, without LED (sold in lots of 10)
Control
circuit
voltage

Number and type of contacts


Thermal current (Ith)
4 C/O - 3 A
Catalog number

RXM4GB1F7

Weight
kg

c 12

RXM4GB1JD

0.037

c 24

RXM4GB1BD

0.037

c 48

RXM4GB1ED

0.037

c 110

RXM4GB1FD

0.037

a 24

RXM4GB1B7

0.037

a 48

RXM4GB1E7

0.037

a 120

RXM4GB1F7

0.037

a 230

RXM4GB1P7

0.037

c 12

RXM4GB2JD

0.037

c 24

RXM4GB2BD

0.037

c 48

RXM4GB2ED

0.037

c 110

RXM4GB2FD

0.037

a 24

RXM4GB2B7

0.037

a 48

RXM4GB2E7

0.037

a 120

RXM4GB2F7

0.037

a 230

RXM4GB2P7

0.037

a 240

RXM4GB2U7

0.037

6
7

Miniature relays with low level contacts, with LED (sold in lots of 10)

RXM4GB2F7

8
9
10

27
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector (continued)

Zelio Plug-In Relays


RXM miniature relays

Miniature relays without LED (sold in lots of 100)


Control
circuit
voltage

1
2
3

RXZE2M114M
+
Relais RXM4AB2F7

Number and type of contacts - Thermal current (Ith)


2 C/O - 12 A
Catalog number
Weight

4 C/O - 6 A
Catalog number

Weight

V
c 12
c 24
c 48
c 110
c 220

RXM2AB1BDTQ

kg

0.037

RXM4AB1JDTQ
RXM4AB1BDTQ
RXM4AB1EDTQ
RXM4AB1FDTQ
RXM4AB1MDTQ

kg
0.036
0.036
0.036
0.036
0.036

a 24
a 48
a 120
a 230

RXM2AB1B7TQ

RXM2AB1F7TQ
RXM2AB1P7TQ

0.037

0.037
0.037

RXM4AB1B7TQ
RXM4AB1E7TQ
RXM4AB1F7TQ
RXM4AB1P7TQ

0.036
0.036
0.036
0.036

0.037
0.037

RXM4AB2BDTQ
RXM4AB2B7TQ
RXM4AB2P7TQ

0.036
0.036
0.036

Catalog number

Weight
kg
0.048

Miniature relays with LED (sold in lots of 100)

c 24
a 24
a 230

RXM2AB2B7TQ
RXM2AB2P7TQ

Sockets

Contact terminal
arrangement
Mixed

Connection

Relay type

Sold in
lots of
10

Screw clamp terminals

RXM2pppp (3)
RXM4pppp
RXM2pppp (3)
RXM4pppp
RXM2pppp
RXM3pppp
RXM4pppp

RXZE2M114 (1)

10

RXZE2M114M (1)

0.056

10
10
10

RXZE2S108M (2)
RXZE2S111M (1)

0.058
0.066
0.070

For
use with

Sold in
lots of

Catalog number

V
c 6...250

All sockets

20

RXM040W

kg
0.003

RC circuit

a 24...60
a 110...240

All sockets
All sockets

20
20

RXM041BN7
RXM041FU7

0.010
0.010

Varistor

a/c 6...24
a/c 24...60
a/c 110...240

All sockets
All sockets
All sockets

20
20
20

RXM021RB
RXM021BN
RXM021FP

0.030
0.030
0.030

Box lug connector


Separate

Box lug connector

RXZE2S114M (1)

Protection modules
RXZE2S114M
+
Relais RXM4AB2F7

Diode

6
7

Description

RXM041pp7

Voltage

Weight

Timing relays
Description
2 or 4 timed C/O contacts
(function A)

For
use with
Sockets RXZEppppp

Catalog number
REXL2pp (4)
REXL4pp (4)

Weight
kg

Accessories
Description

REXL4pp

9
RXZ400

For
use with
Metal hold-down clip
All sockets
Plastic hold-down ejector clip All sockets
Bus jumper 2-pole (Ith: 5 A)
All sockets with separate contacts

Sold in
lots of
10
10
10

Catalog number

RXZS2

Mounting adapter
for DIN rails (5)
Mounting adapter
with fixing lugs for panel
Clip-in ID tags

All relays

10

RXZE2DA

0.004

All relays

10

RXZE2FA

0.002

All relays (sheet of 108 ID tags)


All sockets except RXZ E2M114

10
10

RXZL520
RXZL420

0.080
0.001

RXZ400
RXZR335

Weight
kg
0.001
0.005
0.005

(1) Thermal current Ith: 10A


(2) Thermal current Ith: 12A
(3) When mounting relay RXM2ppppp on socket RXZE2Mpppp, the thermal current must not exceed 10A.
(4) Please consult the "Zelio Time - timing relays" catalog.
(5) Test button becomes inaccessible.

10
Introduction:
page 24

Characteristics :
pages 25 and 26

Product selector:
pages 27 and 28

Dimensions:
pages 29 and 30

Wiring diagrams:
page 31

28
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions

RXM miniature relays

Dimensions (mm):
Miniature relays
RXMpppppp
Common view

RXM2
Pin side view

RXM3

21

21
40

4,4 4,4 4,4

27

6,3 6,3 4,2 4,2

6,6 6,6

RXM4

21

2,5

2,5

2,5

2,5

13,2

4,4
2,5

13,2

2,5
13,2

Sockets
RXZE2M114

RXZE2M114M

40

43
25,5

19

17

(4)
14
5

32

22

12

11

(2)

A2
14

9
23
7

30

A1
13

39,5

34

24 14
6

42

32

22 12

(2)

(3)

A2
14

A1

41

31

21

41

31

21

13
11

12

11

10

12

11

10

(4)

21

50
7

30

80

61

(1)

44

40

24
6

44
8
42

3,5

(3)

79

(1)

34
7

23,5

67

27

69

Common side view

RXZE2S108M

RXZE2S111M

RXZE2S114M

61

19

44
8

14
5

34

42
4

12
1

32

21
9

8
24

31

21 11

12
44

11
34

10 9
24 14

8
42

7
32

6
5
22 12

14
5

22
3

41

11

12
2

70

A2

A1

14

13

38

38

38

(5)
29

23
7

31

(2)

3,5

(3)

11
9

79

(1)

41
12

A2

A1
14

13

A2

A1
14

13

23,5

23,5

23,5

27

27

27

(1) Relay
(2) Protection module
(3) Metal hold-down clip
(4) 2 elongated holes 3.5 x 6.5
(5) 2 bus jumpers

10

29
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions (continued)

RXM miniature relays

Dimensions (mm):

Plastic hold-down clip and clip-in ID tags


RXZR335

RXZL420

26,5
(1)

94,5

27

12

57

Mounting on all sockets (1)

14,2

3
81

(1) Clip-in ID tags for all sockets except


RXZE2M114

Bus jumper

Metal hold-down clip

RXZS2

RXZ400

7,3

22

25

2,2

Mounting on sockets with separate contacts


(view from below)
Example of bus jumper mounting on sockets

22

(1)

(1)

2,3

42

(2)

(2)

0,8

6
(1) 2 bus jumpers (polarity A2)
(2) 2 bus jumpers (polarity A1)

RXZE2FA

38

43

38

Mounting adapter for panel

RXZE2DA

48

Mounting adapter for DIN rails (1)

8
3

3,5

3,5
49

4
24

24

23

48

51

(1) Test button becomes inaccessible

10
Introduction:
page 24

Characteristics :
pages 25 and 26

Product selector:
pages 27 and 28

Dimensions:
pages 29 and 30

Wiring diagrams:
page 31

30
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Wiring diagrams

Zelio Plug-In Relays


RXM miniature relays

Internal connections
Miniature relays

1
A2
A1

42

44
41

32

34

12
5

42
8

12

22

32

12
5

22
6

32
7

42
8

14
9

44
12

14
7

24
8

34
9

14
9

24
10

34
11

44
12

11
13

41
14

21

21

31

41
14

A2

31
14

11
13

A1

11
13
A1

A2

31

22

24
21

12

14

21

11

11

A2
A1

32

34

RXM4ppppp

31

22

24

12

14

A2
A1

42

44
41

14

RXM3ppppp

11

12

RXM2ppppp

A1

2
3

A2

Symbols shown in blue correspond to Nema marking.

Sockets
RXZE2M114

4
42

RXZE2M114M
6
7
34 24
8
5
44 14
3
2
1
32 22 12

8
44

7
34

6
24

5
14

4
42

3
32

2
22

1
12
1

5
9

14
A2
12
41

13
A1
11
31

9
11
10
21

14

13

A2
14
41 31
12 11

A1
13
21
10

11
9

Symbols shown in blue correspond to Nema marking.


RXZE2S108M

RXZE2S111M
9
11
5
14

9
31
6
34

8
21
5
24

7
11
4
14

4
42

1
12

3
32

2
22

1
12

A1

A2

14
A2

RXZE2S114M

12
41
8
44

A1

A2

13
INPUT A1

14
A2

12
41
8
44
4
42

13
INPUT A1

11
31
7
34
3
32

10
21
6
24
2
22

A1

A2

14
A2

9
11
5
14
1
12

13
INPUT A1

Symbols shown in blue correspond to Nema marking.

Protection modules
RXM040W

RXM041ppp

RXM021ppp

A2

A2

A2

+ A1

+ A1

+ A1

9
10

31
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Introduction

RUM universal relays

Introduction of the product range

The RUM universal relay range includes:


1 10 A relays with 2 and 3 C/O contacts, with cylindrical or quick-connect terminals,
and 3 A low level relays with 3 C/O contacts, with cylindrical pins. All RUM relays
have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module.
4 Metal hold-down clip for all sockets.
5 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify wiring when creating a jumper between the coil terminals.
6 Clip-in ID tags for the sockets.

4
5

Relay description

1 Spring return push-to-test button for checking contact operation (green: c,


red: a).
2 Mechanical relay status indicator.
3 Optional removable lock-down door enables continuous engagement of the
contacts for test or maintenance purposes. During operation, this lock-down door
must always be in the closed position.
4 Bipolar LED (depending on version) indicating the relay status.
5 Removable ID tag for relay identification.
6 Area by which the product can be easily gripped.
7 Eight or eleven cylindrical pins.
8 Eight or eleven quick-connect pins

1
2
3
4

4
5

5
6

Socket description

Outputs

Sockets with mixed contact terminals (1)


1 Box lug connectors.
2 Eight or eleven female contacts for the relay cylindrical pins.
3 Location for protection modules or the timer module.
4 Locking component for metal hold-down clip.
5 Locating slot for mounting on DIN rail.
6 Two mounting holes for panel mounting.

2
6
4

3
Relay supply

Inputs
Relay suppy

6
1

Inputs

Sockets with separate contact terminals (2)


1 Box lug connectors.
Outputs 2 a Eight or eleven female contacts for the relay cylindrical pins.
b Eleven female contacts for the relay flat pins.
2b 3 Location for protection modules or the timer module.
4 Locking component for metal hold-down clip.
5 Locating slot for mounting on DIN rail.
4
6 Two mounting holes for panel mounting.
7 Location for bus jumpers (see mounting on sockets on page38).
3
Inputs

Outputs

4
2a
3

10
57

Introduction:
page 32

Relay supply

57

5 Relay supply

Characteristics:
pages 33 and 34

(1) The inputs are mixed with the relay coil terminals, with the outputs being located on the
opposite side of the socket.
(2) The inputs and outputs are separated from the relay coil terminals.

Product selector:
pages 35 and 36

Dimensions:
pages 37 and 38

Wiring diagrams:
pages 39 and 40

Functions:
page 41

32
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics

RUM universal relays

General characteristics

Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

Insulation characteristics

Rated insulation voltage (Ui)

Conforming to IEC/EN 60947

C (F)
C (F)

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8;
CSA; CE; RoHS compliant
- 40 + 85 (-40... +185)
- 40 + 55 (-40... +131)
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
4gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
10 gn
10 gn
RT I
Any

250 (IEC), 300 (UL, CSA)

Rated impulse withstand voltage (Uimp)

kV

4 (1.2/50 s)

Dielectric strength
(rms voltage)

aV
aV
aV

1550
1550
1500

Between coil and contact


Between poles
Between contacts

Contact characteristics

Relay type
Number and type of contacts

RUMF2ppp
2 C/O

Contact materials
Conventional thermal
current (Ith)

For ambient
temperature y 55C

Rated operational current


in utilization categories
AC-1 and DC-1

Conforming to IEC

AgNi

AgAu

10

NO

10

16 / a277V
12 / c28V

3
3

Minimum

mA

10

Maximum

a/c 250 (IEC)

Minimum
Nominal load (resistive)
a
c
Minimum

17

10 / 250a V

3 / 250a V

10 / 28c V

3 / 28c V

VA

2500

750

280

84

mW

170

15

No-load

18 000

Under load

1200

In millions of operating cycles

Electrical durability
In millions of operating cycles

Resistive load

0.1

Inductive load

See curves below

106

1
0,8
0,6
0,5

8
10
3

0,4

105
0

Maximum switching capacity on resistive load


c
Current c

Reduction coefficient for inductive load a


(depending on power factor cos )
Reduction coefficient (A)

Durability (Number of operating cycles)

107

1
2
3
Switching capacity (kVA)

A RUMFppppp, RUMC2ppp, RUMC3Appp

6
7

20 %

Mechanical durability

Electrical durability of contacts


Resistive load a

4
5

Utilization coefficient

RUMC3Gpp
3 C/O low level

Switching current

Maximum operating rate


In operating cycles/hour

RUMC3App
3 C/O

NC
Conforming to UL

Maximum

RUMC2ppp
2 C/O

Switching voltage

Switching capacity

RUMF3ppp
3 C/O

0,3

0,6

0,4

0,2

0,1

28 50

100

150

200
250
Voltage c

10

B RUMC3Gppp

Inductive load durability = resistive load durability x reduction coefficient.

33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics (continued)

RUM universal relays

Coil characteristics

Average consumption

c
a

Drop-out voltage threshold


Operating time
(response time)

VA

2...3

1.4
u 0.15 Uc

Between coil energization


and making of the
NO contact

Between coil de-energization


and making of the
NC contact

Control circuit voltage Uc

u 0.1 Uc
ms

20

ms

20

ms

20

ms

20

12

24

48

60

110

120

125

220

230

JD

BD

ED

ND

FD

GD

MD

Relay coil voltage codes

d.c. supply

120

470

1800

2790

10 000

10 000

3700

Min.

9.6

19.2

38.4

48

88

100

176

Max.

13.2

26.4

52.8

66

121

137.5

242

B7

E7

F7

P7

Average resistance at 20 C 10%


Operating
voltage limits

Relay control voltage codes


a.c. supply

4
5

72

290

1700

7200

Min.

19.2

38.4

96

184

Max.

26.4

52.8

132

253

Average resistance at 20 C 15%


Operating
voltage limits

Socket characteristics
Socket type

RUZC2M

RUZC3M

RUZSC2M

RUZSC3M

RUZSF3M

Relay types used

RUMC2ppppp

RUMC3ppppp

RUMC2ppppp

RUMC3ppppp

RUMFppppp

Contact terminal arrangement

Mixed

Wire connection method

Connector

Product certifications

cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant

Conforming to standards

IEC 61984, e

Electrical characteristics

Conventional thermal current (Ith)

10

Maximum operating voltage

250 (IEC)

Between adjacent output contacts

Vrms

2500

Between input and output contacts

Vrms

2500

Between contacts and DIN rail

Vrms

2500

Insulation characteristics

General characteristics

Ambient air temperature


around the device

12

Operation

C (F)

- 40+ 55 (-40... +131)

Storage

C (F)

- 40+ 85 (-40.... +185)

Degree of protection

Conforming to IEC/EN 60529

IP 20

Connection

Solid wire
without
cable end

1 conductor

0.52.5 mm2 - AWG 20AWG 14

2 conductors

0.51.5 mm2 - AWG 20AWG 16

Flexible wire
with cable end

1 conductor

0.252.5 mm2 - AWG 22AWG 14


0.251 mm2 - AWG 22AWG 17

2 conductors

Maximum tightening torque / Screw size

Separate

Nm

1 / M3.3 screw

Mounting

35 mm DIN rail / panel

Mounting on DIN rail

By red plastic clip

Terminal referencing

IEC, NEMA

Bus jumper (Ith: 5 A)

No

Compatibility with the metal hold-down clip

Yes

Timer module

Yes

Protection module

All RUW24ppp

Clip-in ID tags
Wire connection method

Yes

No

Yes

Box lug connector

10
Introduction:
page 32

Characteristics:
pages 33 and 34

Product selector:
pages 35 and 36

Dimensions:
pages 37 and 38

Wiring diagrams:
pages 39 and 40

Functions:
page 41

34
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RUM universal relays

Product selection

Relays for standard applications, without LED (sold in lots of 10)


Pins

Cylindrical

RUMppAB1F7

Flat (quick-connect)

Control
circuit voltage

Number and type of contacts - Thermal current (Ith)


2 C/O - 10 A
3 C/O - 10 A
Catalog number
Weight
Catalog number

RUMppAB2F7

Flat (quick-connect)

Weight

V
c 12
c 24
c 48
c 60
c 110
c 125
c 220

RUMC2AB1JD
RUMC2AB1BD
RUMC2AB1ED

RUMC2AB1FD

kg
0.085
0.085
0.085

0.085

RUMC3AB1JD
RUMC3AB1BD
RUMC3AB1ED
RUMC3AB1ND
RUMC3AB1FD
RUMC3AB1GD
RUMC3AB1MD

kg
0.088
0.088
0.088
0.088
0.088
0.088
0.088

a 24
a 48
a 120
a 230

RUMC2AB1B7
RUMC2AB1E7
RUMC2AB1F7
RUMC2AB1P7

0.085
0.085
0.085
0.085

RUMC3AB1B7
RUMC3AB1E7
RUMC3AB1F7
RUMC3AB1P7

0.088
0.088
0.088
0.088

c 12
c 24
c 48
c 110

RUMF2AB1JD
RUMF2AB1BD
RUMF2AB1ED
RUMF2AB1FD

0.080
0.080
0.080
0.080

RUMF3AB1JD
RUMF3AB1BD
RUMF3AB1ED
RUMF3AB1FD

0.082
0.082
0.082
0.082

a 24
a 48
a 120
a 230

RUMF2AB1B7
RUMF2AB1E7
RUMF2AB1F7
RUMF2AB1P7

0.080
0.080
0.080
0.080

RUMF3AB1B7
RUMF3AB1E7
RUMF3AB1F7
RUMF3AB1P7

0.082
0.082
0.082
0.082

c 12
c 24
c 48
c 60
c 110
c 125

RUMC2AB2JD
RUMC2AB2BD
RUMC2AB2ED

RUMC2AB2FD

0.085
0.085
0.085

0.085

RUMC3AB2JD
RUMC3AB2BD
RUMC3AB2ED
RUMC3AB2ND
RUMC3AB2FD
RUMC3AB2GD

0.088
0.088
0.088
0.088
0.088
0.088

a 24
a 48
a 120
a 230

RUMC2AB2B7
RUMC2AB2E7
RUMC2AB2F7
RUMC2AB2P7

0.085
0.085
0.085
0.085

RUMC3AB2B7
RUMC3AB2E7
RUMC3AB2F7
RUMC3AB2P7

0.088
0.088
0.088
0.088

c 12
c 24
c 48
c 110

RUMF2AB2JD
RUMF2AB2BD
RUMF2AB2ED
RUMF2AB2FD

0.084
0.084
0.084
0.084

RUMF3AB2JD
RUMF3AB2BD
RUMF3AB2ED
RUMF3AB2FD

0.082
0.082
0.082
0.082

a 24
a 48
a 120
a 230

RUMF2AB2B7
RUMF2AB2E7
RUMF2AB2F7
RUMF2AB2P7

0.084
0.084
0.084
0.084

RUMF3AB2B7
RUMF3AB2E7

0.082
0.082
0.082
0.082

Relays for standard applications, with LED (sold in lots of 10)


Cylindrical

RUMF3AB2F7
RUMF3AB2P7

Relays with low level contacts, with LED (sold in lots of 10)
Pins

Cylindrical

Control
circuit voltage

2
3
4
5
6
7
8

Number and type of contacts


Thermal current (Ith)
3 C/O - 3 A
Catalog number
Weight

V
c 24
c 48

RUMC3GB2BD
RUMC3GB2ED

kg
0.086
0.086

a 24
a 48
a 120
a 230

RUMC3GB2B7
RUMC3GB2E7
RUMC3GB2F7
RUMC3GB2P7

0.086
0.086
0.086
0.086

9
10

35
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector (continued)

Zelio Plug-In Relays


RUM universal relays

Product selection (continued)

Sockets

Contact terminal
arrangement

Connection

Mixed

Box lug connector

Separate

Relay type

Box lug connector

Sold in
lots of

Catalog number

RUMC2ppppp

10

RUZC2M

0.054

RUMC3ppppp

10

RUZC3M

0.054

RUMC2ppppp

10

RUZSC2M

0.095

RUMC3ppppp

10

RUZSC3M

0.100

RUMF2pppp

10

RUZSF3M

0.095

Sold in
lots of

Catalog number

RUMF3pppp
RUZC3M + relais RUMC3ppppp

Protection modules
Description

For
use with

Voltage

Diode

All sockets

c 6250

10

RUW240BD

0.004

RC circuit

All sockets

a 110240

10

RUW241P7

0.004

Varistor

All sockets

a/c 24

10

RUW242B7

0.004

a/c 240

10

RUW242P7

0.004

3
RUW241P7

Weight
kg

Timer module
Description

For
use with

Voltage

All sockets

a/c 24 240

Catalog number

V
Multifunction

Weight
kg

RUW101MW

Weight
kg

RUW101MW

0.020

Timing relays
Description

For
use with

Catalog number

2 timed C/O contacts


On sockets RUZCpM
(single-function or multifunction)

RE48App
(1)

Weight
kg

Accessories

Description

RUZC200

7
RUZS2

For
use with

Sold in
lots of

Catalog number

Weight
kg

Metal hold-down clip

All sockets

10

RUZC200

0.001

Bus jumper 2-pole (Ith : 5 A)

All sockets with separate contacts

10

RUZS2

0.005

Clip-in ID tags

All relays
(sheet of 108 ID tags)

10

RXZL520

0.080

All sockets with separate contacts

10

RUZL420

0.001

(1) Please consult the "Zelio Time timing relays" catalog.

8
9
10
Introduction:
page 32

Characteristics:
pages 33 and 34

Product selector:
pages 35 and 36

Dimensions:
pages 37 and 38

Wiring diagrams:
pages 39 and 40

Functions:
page 41

36
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions

RUM universal relays

Dimensions (mm):
Universal relays

RUMFpp

55

35

35

RUMCpp

35

53

35

Sockets
Common side view

RUZC2M

RUZC3M

22
24

22

32

24

22

14

12

(1)

34
3

A2

A2
7

27
63

21

11

89

2
1

INPUT A2
10
A2 A2

A1

10

11

INPUT A1
2

37

37

(2)

10

8
INPUT A2
7

74

(3)

12 14

31
10

21
11

30

30

38

38

INPUT A1
2
11

A1
1

93
RUZSC2M

RUZSC3M

63

45
19

19

24
6

21
8

92

12
4
14
3

(3)

40
102
105

(2)
A1
2

34
9

24
7

14
3

32

22

12

30

29

36

75

7
8

A2
10

(4)
4

29

11
1

A2
7

75

21
6

7 6 5
8
4
3
9
10
2
11 1

2
8

(4)

(1)

(2)

31
11

40

(1)
(3)

11
1

92

22
5

A1
2

32
36

102
105

(1) Relays
(2) Protection module
(3) Retention clip
(4) 2 bus jumpers

10

37
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions (continued)

RUM universal relays

Dimensions (mm):

Sockets (continued)
RUZSF3M

63
21
9

31
8

11
7

24
6

34
5

14
4

22

32

12

(1)
92

(3)

(2)
A2
B

(4)
46

29

27

A1
A

36

104

(1) Relays
(2) Protection module
(3) Retention clip
(4) 2 bus jumpers

Metal hold-down clip and plastic ID tags


Mounting

35

RUZC200

108

0,8

RUZL420

32
12

59,6

14,2

Bus jumper
RUZS2

Mounting on sockets with separate contacts (view from below)


Example of bus jumper mounting on sockets

(1)

(1)

(2)

(2)

8,5

3,3

35,4

32
2,3

10

(1) 2 bus jumpers (polarity A2)


(2) 2 bus jumpers (polarity A1)

Introduction:
page 32

Characteristics:
pages 33 and 34

Product selector:
pages 35 and 36

Dimensions:
pages 37 and 38

Wiring diagrams:
pages 39 and 40

Functions:
page 41

38
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Wiring diagrams

RUM universal relays

Wiring diagrams
Universal relays

1
24

A2
A1

22

21

34

32

31

14

12

A2
A1

11

34

32

RUMF3ABppp

31

24

22

21

14

12

A2
A1

11

24

22

RUMC3ppppp

21

14
11

12

RUMp2ABppp

2
RUMC2ABppp

RUMF2ABppp

12
4
14

A1

22

11

24

A2

8
21

RUMC3ppppp

12
4

22
6

14
7

24
9

11
A (+)

21
B( )

A1

A2

22
12

RUMF3ABppp

21
6

24

14 3
A1

32

9 34
2

10
11
31

1
11

A2

12
4

32
5

22
6

14
7

34
8

24
9

11
A (+)

31

21
B( )

A2

A1

Symbols shown in blue correspond to Nema marking.

Sockets
RUZC2M

RUZC3M

RUZSC2M

24 22

12

14

34

32

24

22

14 12

6
7

7
A2

7
A2

8
21

6 5
7

9
10

1
11

2
A1

10 10
A2 A2

11
31

6
21

4
12
3
14

1
11
8
21

6
21
7
24
5
22

11
31
8
32
9
34

4
5

3
11 1

RUZSC3M

5
22
6
24

1
11

2
A1

7
A2

9
10

2
A1

10
A2

6 5

1
11
4
12
3
14

3
11 1

2
A1

Symbols shown in blue correspond to Nema marking.


RUZSF3M
9
21
6
24

8
31
5
34

7
11
4
14

3
22

2
32

1
12

B
A2

8
9

A
A1

Symbols shown in blue correspond to Nema marking.

10

39
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Wiring diagrams (continued)

Zelio Plug-In Relays


RUM universal relays

Wiring diagrams (continued)

Protection modules
RUW240BD

RUW241P7

RUW242pp

A2

A2

A2

+ A1

+ A1

+ A1

2
3
4
5
6
7
8
9
10
Introduction:
page 32

Characteristics:
pages 33 and 34

Product selector:
pages 35 and 36

Dimensions:
pages 37 and 38

Wiring diagrams:
pages 39 and 40

Functions:
page 41

40
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Functions

RUM universal relays

Multifunction timer module RUW101MW


Programming

Timing range selection

Function Timing range


selection selection
0.11 s

0.110 s

0.11 min

110 min

0.11 h

0.11 day

110 h

110 days

2
Function selection
Series control

Monostable with
maintained control
Wu

Series control

Flashing relay,
starting On-delay phase
Bi

Series control

Flashing relay,
starting Off-delay phase
Bp

Series control

Off-delay timer
R

R
t

t t

U
.1/.4
.1/.2

Monostable, starting
on de-energization
Wa

On-delay Timer
Es

Control by external contact


(S)

t t

U
S

A2

U
S
.1/.4
.1/.2

Control by external contact


(S)

.1/.4
.1/.2

Control by external contact


(S)

U
.1/.4
.1/.2

.1/.4
.1/.2

Monostable
with pulse control
Ws

U
.1/.4
.1/.2

Control by external contact


(S)

U
.1/.4
.1/.2

Control scheme

B1

On-delay Timer
E

Function diagram

A1

Control

A2

Function

A1

Selection

U
S
.1/.4
.1/.2

Power off

Contact open

U : voltage

S : external control

Power on

Contact closed

R : relay RUM ppp

t : adjustable time delay

10

41
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Introduction

RPM power relays

Introduction of the product range

The RPM power relay range includes:


1 15 A relays with 1, 2, 3 and 4 C/O (SPDT, DPDT, 3PDT and 4PDT) contacts.
2 Sockets with mixed contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module. Please note
that the timer module can only be used with 3-pole or 4-pole sockets.
4 Metal hold-down clip for single-contact relays (not shown).

3
8

Relay description

1 Spring return push-to-test button for checking contact operation (green: c,


red: a).
2 Mechanical relay status indicator.
3 Removable lock-down door enables continuous engagement of the contacts for
testing or maintenance purposes. During operation, this lock-down door must
always be in the closed position.
4 Bipolar LED (depending on version) indicating the relay status.
5 Removable ID tag for relay identification.
6 Four notches for DIN rail mounting adapter or panel mounting adapter with fixing
lugs.
7 Five, eight, eleven or fourteen quick-connect pins.
8 Area by which the product can be easily gripped.
9 Mounting adapter enabling direct mounting of the relay on a panel.
10 Mounting adapter enabling direct mounting of the relay on a DIN rail.

2
3
4
5

7 6

5
9

6
7
10

Socket description

5
1

Outputs

Sockets with mixed contact terminals (1)


1 Connection by screw clamp terminals.
2 Five, eight, eleven or fourteen female contacts for the relay pins.
3 Location for protection modules or the timer module.
4 Locating slot for mounting on DIN rail with mounting clip.
5 Two or four mounting holes for panel mounting.
(1) The inputs are mixed with the relay coil terminals,, with the outputs being located on the
opposite side of the socket.

Relay supply

9
4

Inputs

10
Introduction:
pages 42

Characteristics:
pages 43 and 44

Product selector:
pages 45 and 46

Dimensions:
pages 47 and 48

Wiring diagrams:
page 49

42
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics

RPM power relays

General characteristics

Conforming to standards
Product certifications
Ambient air temperature
around the device

Storage
Operation
Vibration resistance
In operation
conforming to IEC/EN 60068-2-6 Not operating
Degree of protection
Conforming to IEC/EN 60529
Shock resistance
Opening
conforming to IEC/EN 60068-2-27 Closing
Protection category
Mounting position

Insulation characteristics

Rated insulation voltage (Ui) Conforming to IEC/EN 60947


Rated impulse withstand voltage (Uimp)
Dielectric strength
Between coil and contact
(rms voltage)
Between poles
Between contacts

IEC/EN 61810-1 (iss. 2), UL 508, CSA C22-2 n 14


cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8;
CSA; CE; RoHS compliant
- 40 + 85 (-40... +185)
- 40 + 55 (-40... +131)
3gn (10...150Hz/ 1 mm / 5g/5 cycles)
5gn (10...150Hz/ 1 mm / 5g/5 cycles)
IP 40
15 gn
15 gn
RT I
Any

V
kV
aV
aV
aV

250 (IEC), 300 (UL, CSA)


4 (1.2/50 s)
1550
1550
1500

RPM1ppp
1 C/O
AgNi
15

C (F)
C (F)

Contact characteristics

Relay type
Number and type of contacts
Contact materials
Conventional thermal
For ambient
current (Ith)
temperature y 55 C
Rated operational current
Conforming to IEC
in utilization categories
AC-1 and DC-1
Conforming to UL
Switching current
Minimum
Switching voltage
Maximum
Minimum
Nominal load (resistive)

NO
NC

Switching capacity

Maximum

a
c

Maximum operating rate


In operating cycles/hour

Minimum
No-load
Under load

Electrical durability
In millions of
operating cycles

106

105

4
3,75
Switching capacity (kVA)

5
6

20 %
10
0.1
See curves below

1
0,8
0,6
0,5

0,4

0,3

0.06

Reduction coefficient for inductive load a


(depending on power factor cos )
Reduction coefficient (A)

Durability (Number of operating cycles)

107

RPM4ppp
4 C/O

15
7.5
15
10
a/c 250 (IEC)
17
15 / 250a V
15 / 28c V
3750
420
170
18 000
1200

In millions of
operating cycles
Resistive load
Inductive load

Electrical durability of contacts


Resistive load a

RPM3ppp
3 C/O

Maximum switching capacity on resistive load


c
Current c

Utilization coefficient
Mechanical durability

A
A
A
mA
V
V
A
A
VA
W
mW

RPM2ppp
2 C/O

15
10

0,1

0,6

0,4

0,2

9
0

28 50

100

150

200
250
Voltage c

Inductive load durability = resistive load durability x reduction coefficient.

10

43
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics (continued)

RPM power relays

Coil characteristics

Relay type
Average consumption

RPM2ppp
1.2
0.9

RPM3ppp
1.5
1.7

RPM4ppp
1.5
2

ms

RPM1ppp
0.9
0.7
u 0.15 Uc
u 0.1 Uc
20

25

25

20

ms

20

25

25

20

ms

20

ms

20

12

24

48

110

120

230

RPM1ppp
RPM2ppp
RPM3ppp
RPM4ppp
Min.
Max.

V
V

JD
180
160
100
96
9.6
13.2

BD
750
650
400
388
19.2
26.4

ED
2600
2600
2600
1550
38.4
52.8

FD
13 100
11 000
8600
7340
88
121

RPM1ppp
RPM2ppp
RPM3ppp
RPM4ppp
Min.
Max.

V
V

B7
160
180
103
84.3
19.2
26.4

E7
720
770
770
338
38.4
52.8

F7
4430
4430
2770
2220
96
132

P7
15 720
15 000
12 000
9120
184
253

Drop-out voltage threshold


Operating time
(response time)

Between coil
energization
and making of the
NO contact

Between coil
de-energization
and making of the
NC contact

a
c
a
c
a

Control circuit voltage Uc

Relay control voltage codes


d.c. supply
Average resistance
at 20 C 10%

Operating
voltage limits

Relay control voltage codes


a.c. supply
Average resistance
at 20 C 15%

Operating
voltage limits

5
6
7

Socket characteristics
Socket type

RPZF1

RPZF2

RPZF3

RPZF4

Relay types used

RPM1ppp

RPM2ppp

RPM3ppp

RPM4ppp

Protection module types used

RXM02ppp
RXM04ppp

RXM02ppp
RXM04ppp

RUW24ppp

RUW24ppp

Contact terminal arrangement


Wire connection method
Product certifications
Conforming to standards

Electrical characteristics

9
10

Mixed
Screw clamp terminals
cURus File E172326 CCN SWIV2, SWIV8; CSA; CE; RoHS compliant
IEC 61984, e

Conventional thermal current (Ith)


Maximum operating voltage

A
V

16
250 (IEC)

Between adjacent output contacts


Between input and output contacts
Between contacts and DIN rail

Vrms
Vrms
Vrms

2500
2500
2500

Ambient air temperature


around the device

C
C

- 40+ 55
- 40+ 85
IP 20
0.51.5 mm2 - AWG 20AWG 16 0.52.5 mm2 - AWG 20AWG 14
0.51.5 mm2 - AWG 20AWG 16 0.52.5 mm2 - AWG 20AWG 14

Insulation characteristics

General characteristics

VA
W

Operation
Storage
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid wire
1 conductor
without
2 conductors
cable end
Flexible wire
1 conductor
with cable end 2 conductors
Maximum tightening torque / Screw size
Mounting
Mounting on DIN rail
Terminal referencing
Compatibility with the metal hold-down clip
Timer module compatibility
Protection module
Clip-in ID tags
Wire connection method
Screw clamp terminals

Introduction:
pages 42

Characteristics:
pages 43 and 44

Nm

0.251 mm2 - AWG 22AWG 17 0.251.5 mm2 - AWG 22AWG 16


0.251 mm2 - AWG 22AWG 17 0.251.5 mm2 - AWG 22AWG 16
1 / M3 screw
1 / M3.5 screw
35 mm DIN rail / panel mount
By red plastic clip
IEC, NEMA
Yes
No
No
Yes
RXM040W, RXM041pp, RXM021pp
RUW24pp
No

Product selector:
pages 45 and 46

Dimensions:
pages 47 and 48

Wiring diagrams:
page 49

44
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RPM power relays

Power relays without LED (sold in lots of 10)


Control
circuit
voltge
V
c 12

Number and type of contacts - Thermal current (Ith)


1 C/O - 15 A
2 C/O - 15 A
3 C/O - 15 A
Catalog
Weight
Catalog
Weight
Catalog
Weight
number
number
number
kg
kg
kg
RPM11JD
0.026
RPM21JD
0.036
RPM31JD
0.054

4 C/O - 15 A
Catalog
Weight
number
kg
0.071
RPM41JD

c 24

RPM11BD

0.026

RPM21BD

0.036

RPM31BD

0.054

RPM41BD

0.071

c 48

RPM11ED

0.026

RPM21ED

0.036

RPM31ED

0.054

RPM41ED

0.071

c 110

RPM11FD

0.026

RPM21FD

0.036

RPM31FD

0.054

RPM41FD

0.071

a 24

RPM11B7

0.026

RPM21B7

0.036

RPM31B7

0.054

RPM41B7

0.071

a 48

RPM11E7

0.026

RPM21E7

0.036

RPM31E7

0.054

RPM41E7

0.071

a 120

RPM11F7

0.026

RPM21F7

0.036

RPM31F7

0.054

RPM41F7

0.071

a 230

RPM11P7

0.026

RPM21P7

0.036

RPM31P7

0.054

RPM41P7

0.071

1
2

RPM41BD

Power relays with LED (sold in lots of 10)

RPM42BD

c 12

RPM12JD

0.026

RPM22JD

0.036

RPM32JD

0.054

RPM42JD

0.071

c 24

RPM12BD

0.026

RPM22BD

0.036

RPM32BD

0.054

RPM42BD

0.071

c 48

RPM12ED

0.026

RPM22ED

0.036

RPM32ED

0.054

RPM42ED

0.071

c 110

RPM12FD

0.026

RPM22FD

0.036

RPM32FD

0.054

RPM42FD

0.071

a 24

RPM12B7

0.026

RPM22B7

0.036

RPM32B7

0.054

RPM42B7

0.071

a 48

RPM12E7

0.026

RPM22E7

0.036

RPM32E7

0.054

RPM42E7

0.071

a 120

RPM12F7

0.026

RPM22F7

0.036

RPM32F7

0.054

RPM42F7

0.071

a 230

RPM12P7

0.026

RPM22P7

0.036

RPM32P7

0.054

RPM42P7

0.071

5
6
7
8
9
10

45
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector (continued)

Zelio Plug-In Relays


RPM power relays

Sockets
Contact terminal
arrangement
Mixed

Connection

Relay type
RPM1ppp
RPM2ppp
RPM3ppp

Sold in
lots of
10
10
10

Screw clamp
terminals

RPZF1
RPZF2
RPZF3

Weight
kg
0.042
0.054
0.072

RPM4ppp

10

RPZF4

0.094

Voltage

Socket type

Sold in
lots of

Catalog number

V
c 6...250

RPZF1RPZF2

20

RXM040W

kg
0.003

10

RUW240BD

0.004

a 24...60

RPZF3
RPZF4
RPZF1RPZF2

20

RXM041BN7

0.010

a 110...240

RPZF1RPZF2

20

RXM041FU7

0.010

10

RUW241P7

0.004

a/c 6...24

RPZF3
RPZF4
RPZF1RPZF2

20

RXM021RB

0.030

a/c 24...60

RPZF1RPZF2

20

RXM021BN

0.030

a/c 110...240

RPZF1RPZF2

20

RXM021FP

0.030

a/c 24

RPZF3
RPZF4
RPZF3
RPZF4

10

RUW242B7

0.004

10

RUW242P7

0.004

Protection modules

Description

RPZF2 + relay RPM22F7

Diode

RC circuit

RUW24ppp
Varistor

a/c 240

Weight

Timer module (1)


Description

Multifunction

Voltage
V
a/c 24 240

Socket type

Catalog number

RPZF3
RPZF4

RUW101MW

Weight
kg
0.020

Accessories
Description

For
use with
RPZF1

Sold in
lots of
20

RPZR235

Weight
kg
0.001

RPM1ppp
RPM2ppp
RPM3ppp
RPM4ppp

20
20
20
20

RPZ1DA
RXZE2DA
RPZ3DA
RPZ4DA

0.004
0.004
0.004
0.006

Mounting adapters with fixing lugs for panel

RPM1ppp
RPM2ppp
RPM3ppp
RPM4ppp

20
20
20
20

RPZ1FA
RXZE2FA
RPZ3FA
RPZ4FA

0.002
0.002
0.003
0.004

Clip-in ID tags
(sheet of 108 ID tags)

All relays

10

RXZL520

0.080

Metal hold-down clip


(for single-pole relays)
Mounting adapters for DIN rail (2)

Catalog number

RPZ1DA

8
RPZ3FA

(1) See timer module description (selection of functions and time delays) on page41
(2) Test button becomes inaccessible.

Introduction:
pages 42

Characteristics:
pages 43 and 44

Catalog number

9
10
Product selector:
pages 45 and 46

Dimensions:
pages 47 and 48

Wiring diagrams:
page 49

46
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions

RPM power relays

Dimensions (mm):
Power relays

RPM1

27

6,5 6 5

3,5

4,7

6
7

Common side view

RPM2

RPM3

RPM4

27

27

7,1 6 4,6 4

39

4,6

4,6 4,6 4,6 4,6

4,6 4,6 4,6

4,6 4,6

21

31

10

27

40

2,6

2,6

14

10

10

41

10

10

10

14,2

Sockets

12

42
4

12
1

(1)

5
6

80

(2)

14

40

40

44

80

(2)
A1

14

13

A2
14

A1
13

11

41

11

12

17

21

71

19

31

A2

40

30

80
RPZF3

30

RPZF4

4,5 x 6

4,5 x 6
24
6

14

22

42
2

8
12

34
7

24
6

42
4

68

(1)

68

44

40

44
8

32
3

14

5
22

12
1

40

19

80

26

76

Common side view

4,5 x 6

(3)

14

(1)

4,5 x 6

19

40

RPZF2

19

68

RPZF1

14

30
76

10

21

A2
13
41

11

12

28

A1

14

13
41

12

A1

4,5 x 6

40

A2

40

(2)

11

31

21

10

36

37

46

40

50

11
9

4,5 x 6

10

(1) Relays
(2) Protection module
(3) Retention clip

47
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions (continued)

RPM power relays

Dimensions (mm):

Mounting adapters for DIN rail

24

2,5

50

44

2,5

50

24

20

34

Mounting adapters with fixing lugs for panel

3,5
16

3,5

16,5

19

24

3,5
19

16

34

3,5

38

38

43

RPZ4FA

43

RPZ3FA

38

43

RXZE2FA

38

RPZ1FA

23

43

RPZ4DA

2,5

23
23

RPZ3DA

38

49,5

RXZE2DA

48

RPZ1DA

4
44

Mounting
Mounting adapters for DIN rail (1)

Mounting adapters with fixing lugs for panel

6
7
(1) Test button becomes inaccessible

8
9
10
Introduction:
pages 42

Characteristics:
pages 43 and 44

Product selector:
pages 45 and 46

Dimensions:
pages 47 and 48

Wiring diagrams:
page 49

48
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Wiring diagrams

RPM power relays

Wiring diagrams
Power relays

1
A2
A1

42

44
41

32

31

34

22

24
21

12

14
11

A2
A1

42

44

RPM4ppp

41

22

24
21

12

14
11

A2
A1

22

24

RPM3ppp

21

12

14

RPM2ppp

11

A2
A1

12

14
11

RPM1ppp

2
1

12

12

42

12

22

42

12

22

32

42

14
9

14
9

44
12

14
9

24
10

44
12

14
9

24
10

34
11

44
12

21

41
14 ( )

11
13 (+)

21

31

41
14 ( )

A2

A1

13 (+)

14 ( )

11
13 (+)

41
14 ( )

11
13 (+)

A1

A2

A1

A2

A1

11

A2

Symbols shown in blue correspond to Nema marking.

Sockets
RPZF1

RPZF2

RPZF3

RPZF4

5
14

8
44

5
14

8
44

6
24

5
14

8
44

7
34

6
24

5
14

1
12

4
42

1
12

4
42

2
22

1
12

4
42

3
32

2
22

1
12

5
14
13
A2
A1
INPUT
9
11

14
A2
12
41

13
A1
9
11

14
A2
12
41

10
21

13
A1

9
11

14
A2
12
41

11
31

10
21

13
A1
9
11

Symbols shown in blue correspond to Nema marking.

Protection modules
RXM040W, RUW240BD

RXM041ppp, RUW241P7

RXM021ppp, RUW242pp

A2

A2

A2

+ A1

+ A1

+ A1

7
8
9
10

49
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Presentation,
characteristics

Zelio Plug-In Relays


RPF power relays

Introduction of the product range

5
2

1
2
3
4
5

30 A relays with 2 C/O or 2 N/O contacts


Four or six quick-connect terminals
Two relay coil terminals
A locating slot for DIN rail mounting
Two holes for panel mounting

2
1

3
4

General characteristics

Conforming to standards

IEC/EN 61810-1 (issue 2), UL 508, CSA C22-2 n14

Product certifications

UL, CSA

Ambient air temperature


around the device

5
6

Storage
Operation

- 40...+ 85 (-40... +185)


- 40...+ 55 (-40... + 131)

Vibration resistance
In operation
conforming to EC/EN 60068-2-6
Not operating

3gn (10...150Hz / 1 mm/5 g/5 cycles)

Degree of protection

Conforming to IEC/EN 60529

IP 40

Shock resistance
conforming to
IEC/EN 60068-2-27

Opening
Closing

10 gn
10 gn

10 gn (10...150Hz / 1 mm/5 g/5 cycles)

Protection category

RT IV

Mounting position

Any

Insulation characteristics

C (F)
C (F)

Rated insulation voltage (Ui)

250

Rated impulse withstand voltage (Uimp)

kV

4 (1,2/50 ms)

Dielectric strength
(rms voltage)

Between coil and contact


Between poles
Between contacts

aV
aV
aV

1550
1550
1500

Characteristics:
page 50

Product selector:
page 52

Conforming to IEC/EN 60947

8
9
10
Dimensions, wiring diagrams:
page 53

50
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Characteristics (continued)

RPF power relays

Contact characteristics

Relay type
Number and type of contacts
Contact materials
Conventional thermal current For ambient
(Ith)
temperature y 40C
Rated operational current
Conforming to IEC
in utilisation category AC-1

A
"C"
O

Conforming to UL
Minimum
Maximum
Minimum

Switching current
Switching voltage

RPF2App
RPF2Bpp
2 N/O
2 C/O
AgSnO2
30 (when mounted with 13 mm gap between two relays)
25 (when mounted side by side without a gap)
30
3
30
10
a/c 250 (IEC)
c 17
30A / 250a V - 30A /28c V (when mounted with 13 mm gap between two relays)
25A / 250a V - 25A /28c V (when mounted side by side without a gap)
7500a VA / 840W (when mounted with 13 mm gap between two relays)
6250a VA / 700W (when mounted side by side without a gap)
170
18 000
1200

A
A
A
mA
V
V

Nominal load (resistive)


Switching capacity

Maximum

Maximum operating rate


In operating cycles/hour

Minimum
No load
Under load

Utilization coefficient
Mechanical durability

In millions of operating cycles

10 %
5

Electrical durability
In millions of operating cycles

Resistive load
Inductive load

0.05 (N/O contact only)


See curves below

mW

Electrical durability of contacts


Resistive load a

105

104

1
0,8
0,6
0,5

0,4

0,3

Switching capacity(kVA)

Coil characteristics

Drop-out voltage threshold


Operating time
(response time)

Between coil
energization
and making of the
On-delay contact
Between coil
de-energization
and making of the
Off-delay contact

Control circuit voltage Uc


Relay control voltage codes
DC supply
Average resistance
at 20 C 10%
Operating
voltage limits
Relay control voltage codes
AC supply
Average resistance
at 20 C 15%
Operating
voltage limits

VA
W

Min.
Max.

10

0,1

0,6

0,2

0,4

28 50

100

150

A RPF 2ppp: 30 A
B RPF 2ppp: 25 A

ms

4
1.7
u 0.15 Uc
u 0.1 Uc
20

ms

20

ms

20

ms

20

12
JD
86

24
BD
350

110
FD
7255

120

230

9.6
13.2

19.2
26.4
B7
250

88
121

F7
3200

P7
13 000

V
V

19.2
26.4

96
132

184
253

V
V

200
250
Voltage c

a
c
a
c
a

W
Min.
Max.

A
B

Durability (inductive load) = durability (resistive load) x reduction coefficient.

Average consumption

Maximum switching capacity on resistive load


c
Current c

Reduction coefficient (A)

Durability (Number of operating cycles)

106

Reduction coefficient for inductive load a


(depending on power factor cos j)

107

8
9
10

51
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Plug-In Relays


RPF power relays

Power relays(sold in lots of 10)


Control
circuit voltage

1
2
RPF 2Bpp

Number and type of contacts - Thermal current (Ith)


2 N/O - 30A (1)
2 C/O - 30A (1)
Catalog number
Catalog number

Weight

V
c 12

RPF2AJD

RPF2BJD

kg
0.082

c 24

RPF2ABD

RPF2BBD

0.082

c 110

RPF2AFD

RPF2BFD

0.082

a 24

RPF2AB7

RPF2BB7

0.082

a 120

RPF2AF7

RPF2BF7

0.082

a 230

RPF2AP7

RPF2BP7

0.082

(1) 30 A when mounted with 13 mm gap between two relays and 25 A when mounted side by side
without a gap.

4
5
6
7
8
9
10

52
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Plug-In Relays

Dimensions,
wiring diagrams

RPF power relays

Dimensions
Power relays

RPF2App, RPF2Bpp

30

26
16

4,7

69

41

60

15

8
=

38

34

Schemes

Power relays
RPF2App

RPF2Bpp

14

24

14

24

4
21
3
22

11
7

11

21

12

A1

A2

A1

A2

5
6
7

Symbols shown in blue correspond to Nema marking.

8
9
10

53
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Selection guide

Interfaces

Interfaces for discrete signals

Applications

Electromechanical interface modules

Functions

Input

Width (mm)

17.5

9.5

Contact arrangement

1 N/O
2 N/O
1 C/O

1 N/O

Thermal current

Control voltages

c 110127 V
z 24 V, 48 V
a 115127 V
a 230/240 V

c 24 V, 48 V
a 115127/50 Hz
a 115127/60 Hz
a 230240/50-60 Hz

Indication

Mechanical for contacts


and/or LED for control

LED for control

Product numbers

ABR1E

ABR2E

Pages

56

62

1
2
3
4
5
6
7
8
9
10

54
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Solid state interface modules

1
2
3
4
Output

Input and output


Very low level switching

Input

Output

9.5/17.5

17.5

12

17.5

9.5

1 N/O
2 N/O
1 C/O
1 N/C + 1 N/O

1 N/O

1 C/O

12 A

5A

c 24 V
z 24 V, 48 V
a 115127 V
a 110 V

c 24 V

Mechanical for contacts


and/or LED for control

LED for control

ABR1S

ABR2S

ABR2pB312B

ABS2E

56

62

62

68

5
5A

c 5, 24, 48 V
a 115127/50 Hz
a 120127/60 Hz
a 230240/50 Hz
a 230240/60 Hz

c 24 V

7
ABS2S

8
9
10

55
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Introduction

Interfaces

For discrete signals

Electromechanical interface modules

ABR-1 electromechanical interface modules are supplied in the form of compact


modules, 17.5 mm wide.
They are designed for interfacing discrete digital control signals exchanged within an
automated system between the processing unit (PLC, numerical controller, etc) and
the other components (contactors, solenoid valves, indicator lamps, proximity
sensors, etc).
These products are based on advanced contactor technology and are easily adapted
to industrial environments. They conform to the most recent IEC 947-5-1 standards.

1
2

Composition
The ABR-1 range includes 2 families:
5

Input interfaces
Input interfaces are designed for switching input signals to the processor and are
characterized by their advanced contact reliability: less than 1 interruption per 100
million operating cycles at c 17 V, 5 mA.
The switching level is sufficiently high to help ensure that the interfaces can directly
control most contactors and indicator lamps.

2
1

4
3

Output interfaces
Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for signalling devices (indicators lamps, audible warnings, etc). They are
characterized by a high switching capacity and an average durability 5 times greater
than that of traditional interface modules, which incorporate standard relays.

1 Override contacts by pressing button (not holding it down) for a simple and quick
test during installation or maintenance operations on the installation
2 Green indicator showing the mechanical position of the contacts
3 LED indicating the control signal state
4 Channel identification : 5 individual characters for AB1-R/G or one AB1-SA2
marker tag
5 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal. The layout of the connection terminals for both families (input and output)
is designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.

4
1
2

6
7
8
9
10
Introduction:
page 56

Characteristics:
pages 57 and 58

Curves:
page 59

Product selector:
page 60

Dimensions, Wiring diagrams:


page 61

56
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics

Interfaces

For discrete signals

Electromechanical interface modules

Examples of applications with PLCs


PLC
Positive logic discrete inputs

+/

PLC
Positive logic transistor (or relay) outputs

+/

A2

A1

A2

A1

A2

+
24...125 V

A1

A2

A1

A2

A1

A2

A1

A2

A1

...240 V

(1)

(1)
Pushbuttons
Series contacts

2-wire
sensors

3-wire
sensors

Pushbuttons
Series contacts

(1) Essential on inductive loads (can be replaced with peak limiter

2-wire
sensors

).

Environment

Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance
Shock resistance
Vibration resistance
Resistance to electrostatic
charges
Resistance to rapid
transients

Conforming to IEC 529


(protection against direct contact)
Conforming to IEC 695-2-1
Conforming to IEC 68-2-27
Conforming to IEC 68-2-6
Conforming to IEC 801-2
Conforming to IEC 801-4

Resistance to shock
waves

Conforming to IEC 255-4

Cross-sections which
may be connected

Flexible wire with no cable end


Flexible wire with cable end
Rigid cable

Operating position
Ambient air temperature
around the device
Operating altitude
Installation category
Degree of pollution
Mounting

IEC 60947-1, UL 508, CSA C22.2 No. 14


UL, CSA, BV, LROS, DNV
IP 00

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
1055Hz
Level 3
On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J
1 or 2-wire
1 or 2-wire
1-wire
2-wire

U 50 V
U > 50 V

kV
kV
kV
kV
kV
mm2
mm2
mm2
mm2
C
C
C
m

Unrestricted operation
Permissible at Un
Storage
Conforming to IEC 947-1
Conforming to IEC 947-5-1

TC
850
V0
50 gn
6 gn
8

2
1
0.5
2.5
0.62.5
0.342.5
0.274
0.272.5
Any
- 5+ 40
- 20+ 60
- 40+ 70

7
8

3000
II
3
Standard DIN rails

9
10
Introduction:
page 56

Characteristics:
pages 57 and 58

Curves:
page 59

Product selector:
page 60

Dimensions, Wiring diagrams:


page 61

57
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Interfaces

For discrete signals

Electromechanical interface modules

Control circuit characteristics (40C ambient temperature)

1
2
3

Type of interface

Rated voltage (Uc)

ABR
1Sp02B
c 24

Current frequency
Energization threshold (at 5 %)
Maximum operating voltage
Maximum drop-out (at 5 %) voltage (Uo)
Maximum current (Un)
Minimum holding current
Maximum dissipated power
Disappearance of voltage
maximum time up to which contact is maintained
Display of control circuit by LED
Built-in protection reversed polarity

Hz
V
V
V
mA
mA
W
ms

15
30
3.2
62
6.6
1.5
3

50/60
16.5
30
3.8
62/55
4.9/5.2
1.5
8

50/60
34
53
8.5
36/32
4.7/5.4
1.5
10

ABR
1Ep12F
c
110...127

75
140
16
15
1.5
1.5
10

No
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Contact characteristics

Type of interface
Maximum switching voltage
Maximum rated
operating voltage Ue

4
5
6

Conforming to IEC 947-5-1

Operating current frequency


Thermal current Ith
Conforming to IEC 947-1
Rated operating
Conforming to IEC 947-5-1
current (Ie)
Ue : a 230 V
per 1 million operating
cycles
Conforming to IEC 947-5-1
Ue : c 24 V

AC12
AC13
AC14
AC15
DC12
DC13

Minimum switching capacity


Minimum switching voltage
Protection against
For Ik 2.5 kA (a) and 100 A (c)
short-circuits
Typeand value of recommended fuse
Low power switching Number of interruptions
performance of contacts per n million operating cycles
(17 V - 5 mA)

Other characteristics

Operating time
at Un and at 20 C

7
8

c/a
c/a
c/a
c/a
50 Hz/60 Hz

Duration of bounce
Contact bridging times
between contact N/C
and N/O
Maximum operating
rate

Between energization of coil and


closing of N/O contact
Between energization of coil and
opening of N/C contact
Between de-energization of coil and
opening of N/O contact
Between de-energization of coil and
closing of N/C contact
Maximum make before break or break
before make time
At no-load
At Ie
ABR-1 (1 N/O or 2 N/O)
ABR-1 (1 C/O or 1 N/C + 1 N/O)

Mechanical durability
inmillions of operating
cycles
Rated isolation voltage Conforming to IEC 947-1
Conforming to VDE 0110 group C
Insulation test voltage Between coil circuit and contact circuits
for 1 min.
Between wired interface and ground
Between independent contacts

aV
cV
aV
cV
Hz
A
A
A
A
A
A
A
mA
V
A

ABR
1ppp8B
z 24

ABR
1ppp8E
z 48

ABR
1ppp1F
a
115...127
50/60
86
140
34
8
2.4
1.5
6

ABR
1Ep11M
a
230...240
50/60
170
264
68
7
2
1.5
5

ABR
1Ep01M
a
230...240
50/60
164
264
78
5.5
1.5
1.5
6

Yes

Yes

No

ABR1Epppp
252
125
230
125
50/60
2
2
1
1
1
2
1
3
17
gG/gF : 16

ABR1Spppp
252
125
230
125
50/60
12
4
1
1
1
5
1
3
17
gG/gF : 16

10-8

10-8

ms

12

ms

12

ms

12

ms

12

ms
ms

3
1

Hz
Hz

6
0.5
20 million
10 million

V
V
kV
kV
kV

250
250
4
2.5
1.5

10
Introduction:
page 56

Characteristics:
pages 57 and 58

Curves:
page 59

Product selector:
page 60

Dimensions, Wiring diagrams:


page 61

58
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Curves

Interfaces

For discrete signals

Electromechanical interface modules

Electrical durability of contacts

Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage, operating rate : 1800 cycles/hour. (0.5 Hz).

a.c. loads
Operating cycles in millions

Operating cycles in millions

3
2

2
1

3
2

3
4

2
3
4

0
0

6
(A)

AC-12 : control of resistive loads and isolated solid


state loads via optocoupler
cos j 0.9

6
(A)

AC-13 : control of isolated solid state loads


via transformer
cos j 0.65

Operating cycles in millions


3

AC-14 : control of weak electromagnetic loads of


electromagnets 72 VA
make: cos j = 0.3
break: cos j = 0.3
AC-15 : control of electromagnetic loads of
electromagnets> 72 VA
make: cos j = 0.7
break: cos j = 0.4

2
3

5
6

1
2
3
4

0
0

0,5

1,5

2,5

24 V
48 V
127 V
230 V

3
(A)

d.c. loads
Operating cycles in millions

Operating cycles in millions

1 24 V
2 48 V
3 127 V

1
4

3
2
1

0
0

3
3

0,5

1,5

2,5

(A)

DC-12 : control of resistive loads and isolated solid


state loads via optocoupler
L/R 1 ms

DC-13 : control of electromagnets


L/R 2 x (Ue x Ie) in ms.
Ue: rated operating voltage
Ie: rated operating current

Introduction:
page 56

Curves:
page 59

Characteristics:
pages 57 and 58

3
(A)

Product selector:
page 60

10
Dimensions, Wiring diagrams:
page 61

59
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Interfaces

For discrete signals

Electromechanical interface modules


Control circuit: a.c. or d.c.

Input interface modules (1) (17.5 mm pitch)


Display

Mechanical (2)
Mechanical (2)
+LED (3)

2
ABR1E101M

Output terminals-relays (1) (17.5 mm pitch)

Display

Mechanical (2)

ABR1E318B
Mechanical (2)
+LED (3)

6
7

Contact
Control circuit
Configuration
V
1 N/O
a 230/240
1 C/O
a 230/240
1 N/O
z 24
z 48
c 110...127 (4)
a 115...127
a 230/240
2 N/O
z 24
z 48
c 110...127(4)
a 115...127
a 230/240
1 C/O
z 24
z 48
c 110...127(4)
a 115...127
a 230/240

Description

ABR1S102B
ABR1S402B
ABR1S302B
ABR1S602B
ABR1S118B
ABR1S118E
ABR1S111F
ABR1S418B
ABR1S418E
ABR1S411F
ABR1S318B
ABR1S318E
ABR1S311F
ABR1S618B
ABR1S618E
ABR1S611F

For common

Catalog number

Coil
Commoning
links in modules
2
8 x 1 mm
a

ABR1E101M
ABR1E301M
ABR1E118B
ABR1E118E
ABR1E112F
ABR1E111F
ABR1E111M
ABR1E418B
ABR1E418E
ABR1E412F
ABR1E411F
ABR1E411M
ABR1E318B
ABR1E318E
ABR1E312F
ABR1E311F
ABR1E311M

Contact
Control circuit
Configuration
V
1 N/O
c 24
2 N/O
c 24
1 C/O
c 24
1 N/C + 1 N/O c 24
1 N/O
z 24
z 48
a 115...127
2 N/O
z 24
z 48
a 110
1 C/O
z 24
z 48
a 110
1 N/C + 1 N/O z 24
z 48
a 110

Commoning links

ABR1S102B

Catalog number

Color

White
Red
Blue

Distance
between
wireends
cm
12
2
12
2
12
2

Catalog
number

ABFC08R12W
ABFC08R02W
ABFC08R12R
ABFC08R02R
ABFC08R12B
ABFC08R02B

Weight
kg
0.090
0.090
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
Weight
kg
0.090
0.090
0.090
0.090
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
Weight
kg
0.020
0.010
0.020
0.010
0.020
0.010

(1) Connection by screw-clamp.


(2) By green mechanical indicator light for contact(s) activated electrically or mechanically by
pressing the test button.
(3) By green LED illuminated when control signal is present.
(4) With polarization (+ on A1, - on A2).

ABFC08Rppp

9
10
Introduction:
page 56

Characteristics:
pages 57 and 58

Curves:
page 59

Product selector:
page 60

Dimensions, Wiring diagrams:


page 61

60
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Dimensions,
Wiring diagrams

Dimensions (mm):

For discrete signals

Electromechanical interface modules

ABR 1S

78

74

74

ABR 1E

78

17,5

70,5

17,5

70,5

75

75

63

63

Wiring diagrams

c 24 V or a 230 V interfaces with mechanical indication


A1

A2

1 N/C + 1 N/O
A1

A1

A2

2 N/O
A2

1 C/O
A1

A2

1 N/O

4
14

13

14

14

11

12

13

24

23

24

23

12

11

z 24 V or z 48 V interfaces with mechanical indication + LED

A1

A2

A2

1 N/C + 1 N/O
A1

2 N/O
A1

A2

1 C/O
A1

A2

1 N/O

7
14

14

13

11

12

14

13

24

23

24

23

12

11

c / a 110 V or a 230 V interfaces with mechanical indication + LED

A2

A1
(+)

1 N/C + 1 N/O
A1
(+)

A2

A2

2 N/O
A1
(+)

1 C/O
A1
(+)

A2

1 N/O

9
14

Introduction:
page 56

13

14

11

12

Characteristics:
pages 57 and 58

14

13

24

23

Curves:
page 59

24

23

12

11

Product selector:
page 60

10
Dimensions, Wiring diagrams:
page 61

61
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Introduction

For discrete signals

Slim electromechanical interface modules

ABR-2 electromechanical interface modules complement the ABR-1 range.


They are characterized by micro relay technology which allows reduced dimensions
and very low switching levels (TTL, HCMOS, analog signals).
The ABR-2 family is in the form of slim compact modules, 9.5 mm wide for input
interface modules, 12 mm wide for output interface modules and 17.5 mm wide for
very low level switching products.

Description

The ABR-2 includes 3 families:


Input interfaces (9.5 mm pitch)
Input interfaces are designed for switching input signals to a processor and are
characterized by their advanced contact reliability: less than 1 interruption per
100million operating cycles at c 17 V, 5 mA.
They have increased immunity to current leakages 2 mA, and a wide coil voltage
range (0.7to 1.25 Un).

1
2

5
3

Output interfaces (12 mm pitch)


Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for signalling devices (indicators lamps, audible warnings etc). They are
characterized by a high switching capacity and an advanced immunity to current
leakages 2 mA. A lower cost version without LED signalling is available.
Low level switching input and output interfaces (17.5 mm pitch)
with 1 C/O contact.
These interfaces are designed for switching logic (TTL or HCMOS) and
analog signals.
Warning: never switch inductive loads with this type of interface.
The front panel of the ABR-2 electromechanical interface module includes:
1 LED indicating the control signal state
2 Channel identification : 5 individual characters for AB1-R/G or 1 AB1-SA2
markertag
3 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal. The layout of the connection terminals for both families (input and output)
is designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.

1
2

7
ABR-2SB312B

ABR2SB312B-PRO-3-B

9
10
Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

62
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Characteristics

For discrete signals

Slim electromechanical interface modules

Examples of applications with PLCs


PLC
Positive logic discrete inputs

PLC
Positive logic transistor (or relay) outputs

Processing
power
supply
+/

PLC
Analogue inputs

Channel X

A2

2
3

11

A1
14

12

A2
14

A1
13

A2
14

A1

14
A2

13

13
A1

A2

14
A2

14

13
A1

A1

14
A2

OV

13

13
A1

+
Process
power
supply

+/

C1

(1)

(1)
Pushbuttons
Series contacts

2-wire
sensors

3-wire
sensors

ABR2Epppp

ABR2Spppp

(1) Essential on inductive loads (can be replaced with peak limiter

C2
Analog
sensors

ABR2SB12B

).

Environment

Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance
Shock resistance
Vibration resistance
Resistance to electrostatic
discharges
Resistance to
electromagnetic fields
Resistance to rapid
transients

Conforming to IEC 529


(protection against direct contact)

Conforming to IEC 68-2-27


Conforming to IEC 68-2-6
Conforming to IEC 801-2

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
10150Hz
Level 3

kV

TC
960
V0
30 gn
3 gn
8

Conforming to IEC 801-3

Level 3 ; 271000 MHz

V/m

10

Conforming to IEC 801-4


Level 3

On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J

kV
kV
kV
kV
kV
mm2
mm2
mm2
C
C

2
1
0.5
1.5
2.5
0.62.5
0.342.5
0.274
Any
- 5+ 40
- 5+ 55

- 25+ 70 (2)

C
m

- 40+ 80
3000
II
2
Standard DIN rails

Conforming to IEC 695-2-1

Resistance to shock
waves

Conforming to IEC 947-1

Cross-sections which
may be connected

Flexible wire with no cable end


Flexible wire with cable end
Rigid cable

Operating position
Ambient air temperature

IEC 60947-1, UL 508, CSA C22.2 No. 14


UL, CSA, BV, LROS, DNV
IP 20

1 or 2-wire
1 or 2-wire
1-wire

Unrestricted operation
Operation from 0.85...1.1 Us
(assigned voltage)
Operation restricted to Us
(assignedvoltage)
Storage

Operating altitude
Installation category
Conforming to IEC 947-1
Degree of pollution
Conforming to IEC 947-1
Mounting
(2) Leave space of 8 mm between ABR-2S1ppp for an ambient temperature 55 C

U < 50 V
U < 150 V
U < 300 V

6
7
8
9
10

Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

63
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Characteristics (continued)

For discrete signals

Slim electromechanical interface modules

Control circuit characteristics (40C ambient temperature)

1
2
3
4
5

Type of interface

Rated voltage (Us)

Current frequency
Energization threshold
Maximum operating voltage
Maximum drop-out voltage (Uo)
Maximum current (at Us)
Minimum holding current
Maximum dissipated power (at Us)

Hz
V
V
V
mA
mA
W
W
ms

50 Hz
60 Hz

Disappearance of voltage
maximum time up to which contact is maintained
Display of control circuit by LED
Built-in protection reversed polarity

Type of interface
Contact configuration
Maximum rated
Conforming to IEC 947-5-1
operating voltage
(Uemax)
Maximum switching voltage

ABR
2E111M
a
230...240
50/60
186
264
48
15
2.5
0.54
0.77
10

16.9
28.8
3.8
28
2

0.64
1

14.5
28.8
2
18
1.3

0.43
5

16.9
28.8
3.8
23
2

0.55
1

Yes
Yes

Yes

Yes

Yes
Yes

No
Yes

Yes
Yes

Operating current frequency


Thermal current Ith
Conforming to IEC 947-1
Rated operating
Conforming to IEC 947-5-1
current (Ie)
Ue max
for 1 million operating
cycles
Conforming to IEC 947-5-1
Ue : c 24 V

aV
cV

AC12
AC14
AC15
DC12
DC13

Low level contact


Number of interruptions
performance (17 V, 5 mA)/ per n million operating cycles
ABR-2pB (30 mV, 10 A)

Maximum operating
Between energization of coil c
time
and closing of N/O contact
a
at Us (bounce included)
Between energization of coil and
opening of N/C contact
Between de-energization of coil c
and opening of N/O contact
a

Other characteristics

ABR
2E116F
z
120...127
60
97
140
25.4
16
2.5

0.73
10

Contact characteristics (40C ambient temperature)

Minimum switching current


Minimum switching voltage
Protection against
For Ik 1 kA (a) and 100 A (c)
short-circuits
Typeand value of recommended fuse

ABR
ABR
ABR
2E112B 2E112E 2E115F
c 24
c 48
z
115127

50
16.9
37.3
93
28.8
57.6
140
3.8
8.5
25.4
19.5
11
14
2
2
2.5

0.66
0.45
0.52

1
1
10

Between de-energization of coil and


closing of N/C contact
Maximum duration of bounce
No make before break Maximum make
On energization
guaranteed between
before break or break On de-energization
N/C and N/O contacts before make time
Maximum operating
At no-load
rate
At Ie
Mechanical durability
inmillions of operating cycles
Rated insulation
Conforming to IEC 947-1
voltage
Conforming to VDE 0110 group C
Insulation test voltage Coil circuit/contact circuits
for 1 min
Wired interface/ground
Between open contacts
(1) Do not switch inductive loads.

aV
cV
Hz
A
A
A
A
A
A
mA
V
A

Yes
Yes

ABR2Epppp
1 N/O
127
100

Yes

ABR2S112B
1 N/O
230
120

ABR
ABR
ABR
2S112B 2S102B 2pB312B (1)
c 24
c 24
c 24

ABR2S102B
1 N/O
230
120

140
250
250
125
150
150
50/60
50/60
50/60
1
5
5
1
3
3
0.5
1
1
0.5
1
1
1
1.7
1.7
1
1.5
1.5
1
5
5
5
5
5
Type : quick-blow fuse with high breaking capacity
2
6.3
6.3
1 per 100 million

ABR2pB312B (1)
1 C/O
48
48
60
60
50/60
0.05

0.01
0.01
0.4

ms
ms
ms

10
30

10

10

ms
ms
ms

6
30

12

ms
ms
ms

2
5
2

Hz
Hz

10
0.5
20

10
0.5
10

10
0.5
10

10

20

V
V
kV rms
kV rms
kV rms

300
250
2
2.5
0.75

300
250
4
2.5
1

300
250
4
2.5
1

300
250
1.5
2.5
1

10
Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

64
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Curves

For discrete signals

Slim electromechanical interface modules

Electrical durability of contacts (ABR 2S)


Test conditions : in accordance with standard IEC 947-5-1 set up for rated control voltage.

a.c. loads
Operating cycles in millions

Operating cycles in millions

1
2
3
4

24 V
48 V
115 V
230 V

2
1

2
1

0
0

1
2
3
4

6
(A)

AC12 : control of resistive loads and isolated solid state


loads via optocoupler
cos j 0.9

0,5

1,5

2,5

3
(A)

AC14 : control of weak electro-magnetic loads of


electro-magnets y 72 VA
make : cos j = 0.3
break : cos j = 0.3
AC15 : control of electro-magnetic loads of
electro-magnets > 72 VA
make : cos j = 0.7
break : cos j = 0.4

d.c. loads
Operating cycles in millions

Operating cycles in millions

1 24 V
2 48 V
3 115 V

1
1

0
0

0,5

1,5

2,5

0,5

1,5

2,5

DC12 : control of resistive loads and isolated solid state


loads via optocoupler
L/R 1 ms

(A)

(A)

DC13 : control of electro-magnets


L/R 2 x (Ue x Ie) in ms.
Ue : rated operating voltage
Ie : rated operating current
(with a load protection diode)

9
10
Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

65
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Interfaces

For discrete signals

Slim electromechanical interface modules


Control circuit: a.c. or d.c.

Input modules (9.5 mm pitch)


Indication

With LED

Contact
Control circuit
Configuration
V
1 N/O
c 24

2
ABR2E112B

Indication

ABR2E112B

kg
0.032

c 48

ABR2E112E

0.032

a 115...127 (50 Hz)

ABR2E115F

0.035

a 120...127 (60 Hz)

ABR2E116F

0.035

a 230...240 (50/60 Hz) 5

ABR2E111M

0.036

Sold in Catalog number


lots of

Without

Contact
Control circuit
Configuration
V
1 N/O
c 24

ABR2S102B

kg
0.040

With LED

1 N/O

ABR2S112B

0.041

c 24

Modules for very low level switching (17.5 mm pitch)

Indication

Input
With LED
ABR2S112B

Weight

Output modules (12 mm pitch)

Weight

Contact
Control circuit
Configuration
V

Catalog number

Weight

1 C/O (1)

c 24

ABR2EB312B

0.048

1 C/O (1)

c 24

ABR2SB312B

0.048

kg

Output

With LED

Flexible comb accessories


Description For common

Flexible
comb
modularity
8 x 1 mm2

Coil

Sold in Catalog number


lots of

ABR2EB112B

Color

White

Red

Blue

Distance
between
wireends
cm
12

Catalog number

Weight

ABFC08R12W

kg
0.020

ABFC08R02W

0.010

12

ABFC08R12R

0.020

ABFC08R02R

0.010

12

ABFC08R12B

0.020

ABFC08R02B

0.010

(1) Not for use with inductive loads.

8
ABFC08Rppp

9
10
Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

66
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Dimensions,
Wiring diagrams

For discrete signals

Slim electromechanical interface modules

Dimensions (mm):

ABR2S1p2B

78

74

74

ABR2E11pp

78

9,5

70,5

75

75

ABR2SB312B

78

78

17,5

70,5

75

75

63

63

ABR2E112B (c 24 V)

17,5

70,5

Circuit diagrams

13

74

74

ABR2EB312B

12

70,5

ABR2E112E (c 48 V)

ABR2E11pF/M (a 115...240 V)

14

13

14

14

13

A2

A1

+A1

A2

A2

ABR2pB312B (c 24 V)

+A1

ABR2S112B (c 24 V)

+A1

A2

ABR2S102B (c 24 V)

A2

+A1

A2

+A1

8
14

13

14

13

11

12
14

9
10

Introduction:
page 62

Characteristics:
pages 63 and 64

Curves:
page 65

Product selector:
page 66

Dimensions, Wiring diagrams:


page 67

67
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Introduction

Interfaces

For discrete signals

Slim solid-state interface modules

The ABS-2 solid-state interface relays are supplied in the form of compact modules
which appear identical to the ABR-2 electromechanical family.
They are designed for interfacing discrete digital control signals exchanged within an
automated system between the processor (PLC, numerical controller, etc) and the
other components (contactors, solenoid valves, indicator lamps, proximity sensors).
They are suitable for use in equipment which requires the benefits of electronic
technology: a high operating rate, enhanced durability, silent operation.
These products are notable for their high performance and excellent adaptation to
industrial environments. They also conform to the most recent IEC standards.

1
2

Composition

The ABS-2 range includes 2 families:


Input interfaces
The 9.5 mm wide input interfaces are designed for switching input signals to
processors. They offer a wide choice of electrical isolation between signals due to
the wide range of input voltages from c 5 V to a 230 V.

2
1

Output interfaces
Output interfaces are designed for the control of preactuators (contactors, solenoid
valves, etc) for the signalling devices (indicator lamps, audible warnings, etc).
Two widths are available, 9.5 and 17.5 mm, depending on the switched current.
The 17.5 mm version includes a 9.5 mm interface and an integrated 8 mm spacer.
This device can, with its increased ventilation, switch high levels of currents.
The front panel of the ABS-2 slim solid-state interface modules includes:
1 LED indicating the state of the control signal.
2 Channel identification : 5 individual characters for AB1-/G or one AB1-SA2 marker
tag.
3 Connection by screw clamp terminal enabling easy attachment of 2 wires per
terminal.
The layout of the connection terminals for both families (input and output) is
designed for rational wiring and a clear separation between the incoming
(processing) and outgoing (power and process control) circuits.
4 Integrated spacer.

3
ABS2INTERSORT-PRO-3-B
1

2
4

ABS-2

ABS2-PRO-3-B

9
10
Introduction:
page 68

Characteristics:
pages 69 to 71

Product selector, curves:


page 72

Dimensions, Wiring diagrams:


page 73

68
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics

Interfaces

For discrete signals

Slim solid-state interface modules

Examples of applications with PLCs

Interfacing PLC discrete inputs

Interfacing PLC discrete outputs

PLC
Positive logic discrete inputs

Processing
powersupply

13

13

13

A2

A1

A2

A1

A1

PNP

Pushbuttons
Series contacts

2-wire
3-wire
sensors sensors

14

13

14

Process
powersupply

13

13

A1

A2

A1

A2

A1

A2

A1

ABS - 2S

A2

A1

A2

13

13

ABS - 2E

A2

14

14

14

14

14

14

PLC
Positive logic transistor (or relay) outputs

115/
230 V
Pushbuttons
Series contacts

2-wire
sensors

Environment

Conforming to standards
Product certifications
Degree of protection
Protective treatment
Flame resistance
Shock resistance
Vibration resistance
Resistance to electrostatic
discharges
Resistance to
electromagnetic fields
Resistance to rapid
transients

Conforming to IEC 529


(protection against direct contact)

Conforming to IEC 68-2-27


Conforming to IEC 68-2-6
Conforming to IEC 801-2

Incandescent wire
Conforming to UL 94
Semi-sinusoidal waves 11ms
10150Hz
Level 3

kV

TC
960
V0
30 gn
5 gn
8

Conforming to IEC 801-3

Level 3 ; 271000 MHz

V/m

10

Conforming to IEC 801-4


Level 3

On power supply
On I/O
Waveform
1.2/50 ms ; 0.5 J

kV
kV
kV
kV
kV
mm2
mm2
mm2

2
1
0.5
1.5
2.5
0.62.5
0.342.5
0.274
Any
- 5+ 55
- 25+ 70
- 40+ 80
300
II
2
Standard DIN rails

Conforming to IEC 695-2-1

Resistance to shock
waves

Conforming to IEC 947-1

Cross-sections which
may be connected

Flexible wire with no cable end


Flexible wire with cable end
Rigid cable

Operating position
Ambient air temperature
around the device
Operating altitude
Installation category
Degree of pollution
Mounting

IEC 60947-1, UL 508, CSA C22.2 No. 14


UL, CSA, BV, LROS, DNV
IP 20

U < 50 V
U < 150 V
U < 300 V

1 or 2-wire
1 or 2-wire
1-wire

C
C
C
m

Unrestricted operation
Operation at Us
Storage
Conforming to IEC 947-1
Conforming to IEC 947-1

6
7
8
9
10

Introduction:
page 68

Characteristics:
pages 69 to 71

Product selector, curves:


page 72

Dimensions, Wiring diagrams:


page 73

69
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Interfaces

For discrete signals

Slim solid-state interface modules

Control circuit characteristics (55C ambient temperature)

1
2

Type of interface
Rated voltage Us

c
a

V
V

Maximum voltage

a
c
a
c

V
mA
mA
V
mA
V
mA
V
mA
V
mA

Maximum current at Us
State 1

State 0

c
a

State 1 display
Internal protection reversed polarity

4
5

Output circuit characteristics

Rated operating voltage Ue


Min/max voltage
Min/max current switched
Maximum residual current at state 0
Maximum volt drop at state 1
Internal protection
External protection

c
c

V
V
mA
mA
V

Other characteristics
Type of interface

Time delay characteristics


Response time max Ue 30 V Ie 5 mA
Maximum switching rate
Duty cycle 50 %
Ue 30 V Ie 5 mA
Rated insulation voltage
Insulation test voltage
for 1 minute

I/O
Wired interface/ground

0V1
1V0

ABS
2EC01EA
5

ABS
2EC01EB
24

ABS
2EC01EE
48

57.6

ABS
2EA01EF

115/127
50 Hz

ABS
2EA02EF

120/127
60 Hz

ABS
2EA01EM

230/240
50 Hz

ABS
2EA02EM

230/240
60 Hz

Negative
logic
6(TTL)

13.6

3.75
4.5

2
0.09

Yes
Yes

28.8

12

16.9
7.7

5.6
2

Yes
Yes

10.5

36
7.5

10.8
2

Yes
Yes

140

14

86.3
8.4

25.4
2.5
Yes

140

17

90
9.7

25.4
2.5
Yes

264

12.5

173
7.9

48
2.5
Yes

264

15

173
9.3

48
2.5
Yes

ABS
2EA02EF
10
20
25

ABS
2EA01EM
10
20
25

ABS
2EA02EM
10
20
25

5...48
2/60
1/50
0.1
1
Reversed polarity
Against short-circuits for Ik 100 A (c)
Quick-blow fuse, ref. : HA21 0.25 A or equivalent

ms
ms
Hz

ABS
2EC01EA
0.05
0.4
1000

ABS
2EC01EB
0.05
0.4
1000

ABS
2EC01EE
0.05
0.4
1000

ABS
2EA01EF
10
20
25

kVrms
kVrms

Conforming to IEC 947-1 : 300 V


Conforming to VDE 0110 : 250 V group C
4
2.5

8
9
10
Introduction:
page 68

Characteristics:
pages 69 to 71

Product selector, curves:


page 72

Dimensions, Wiring diagrams:


page 73

70
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Interfaces

For discrete signals

Slim solid-state interface modules

Control circuit characteristics (55C ambient temperature)

Type of interface
Rated voltage Us
Maximum voltage
Maximum current at Us
State 1

State 0

ABS2SC01EB
24
28.8
12
16.9
7.7
5.6
2
Yes
Yes

ABS2SC02EB

V
V
A

c 5...48
c 57.6
2

A
A
A
A
mA
mA
V

DC12
DC13
DC14

1
1
1.5

V
V/ms

Reversed polarity
Against short-circuits for Ik 1 kA (a) and 100 A (c)
Quick-blow fuse with high breaking capacity: 3.15 A

ms
ms
Hz
Hz
Hz
Hz

0.05
0.6
DC13
DC14

700

kVrms
kVrms

Conforming to IEC 947-1 : z 300 V


Conforming to VDE 0110 : 250 V group C
4
2.5

V
V
mA
V
mA
V
mA

State 1 display
Internal protection reversed polarity

Output circuit characteristics

Rated operating voltage Ue


Maximum voltage
Maximum continuous current (Ith) (1)
at 40 C
Rated operating voltage (Ie)
Conforming to IEC 947-5-1
Single/touching product
at 55 C vertical position
Minimum current
Maximum residual current
Maximum volt drop

c/a
c/a

0 crossing voltage
Solid-state dV/dt
Internal protection
External protection

Other characteristics

Maximum response time


at Ie 10 mA
Maximum switching rate

0V1
1V0
At 55 C ; at Ie: module alone
dutycycle 40 %
On resistive load
duty cycle 50 %

Rated operating voltage


Rated Insulation voltage
for 1 minute

I/O
Wired interface/ground
(1) See temperature derating curves.

1.5/0.9
1.5/0.9
0.6/0.6

6
1

ABS2SA01MB
24
28.8
13.6
16.9
8.3
5.3
2
Yes
Yes

ABS2SA02MB

c 5...48
c 57.6
3

a 24...240
a 264
2.3

a 24...240
a 264
3

2.5/2.2
2.5/2.2
0.6/0.6

AC12
1.9/0.5
AC13
1.6/0.5
AC14
1.6/0.5
AC15
1/0.5
10
2.5
3 (Ie 10 mA)
1.5 (Ie 100 mA)
50 peak
500

2.1/1.5
1.6/1.5
1.6/1.5
1/1

1
2
3
4
5

10 (50 Hz) ; 8 (60Hz)


10 (50 Hz) ; 8 (60Hz)
AC13
0.6
0.7
AC14
0.6
0.7
AC15
0.6
0.7
50

6
3

6
7
8
9
10

Introduction:
page 68

Characteristics:
pages 69 to 71

Product selector, curves:


page 72

Dimensions, Wiring diagrams:


page 73

71
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Product selector,
Curves

Solid-state input modules

Width

mm
9.5

Input circuit
Current Nominal voltage
V
24
c

17.5

Output circuit
Current Nominal voltage
A
V
c2
2448
a 2.3
24230
c3
2448
a3
24230

Solid-state output modules


Width

Slim solid-state interface modules

Output circuit
Current Nominal voltage
V
c
548
c
548
c
548
c
548
c
548
c
548
c
548

Accessories

For discrete signals

Input circuit
Current Nominal voltage
V
5
c
24
48
115127 (50 Hz)
a
120127 (60 Hz)
230240 (50 Hz)
230240 (60 Hz)

mm
9.5

24

ABS2SC01EB d.c.

ABS2EC01EA
ABS2EC01EB
ABS2EC01EE
ABS2EA01EF
ABS2EA02EF
ABS2EA01EM
ABS2EA02EM

Sold in Catalog number


lots of
5
5
1
1

ABS2SC01EB
ABS2SA01MB
ABS2SC02EB
ABS2SA02MB

kg
0.029
0.029
0.029
0.032
0.032
0.033
0.033
Weight
kg
0.034
0.034
0.043
0.044

ABS2SC02EB d.c.
Ie (A)

1/2

3/4

10

20

30

40

50 60 70
T C ambient

ABS2SA01MB a.c.

3
4

10

20

30

40

50 60 70
T C ambient

ABS2SA02MB a.c.

Ie (A)

5
5
5
5
5
5
5

Weight

Temperature derating curve for solid-state output modules Uc = Us = c 24 V

1/2

Sold in Catalog number


lots of

For connecting commons, use ABFC08ppp flexible combs (Please consult your Regional Sales Offices).

Ie (A)

Ie (A)

1/2
3

1/2

4
1

3/4

10

20

30

40

50 60 70
T C ambient

10

20

30

40

50 60 70
T C ambient

1 Vertical module alone or adjacent to modules with


low heat dissipation.

2 Horizontal module alone or adjacent to modules with


low heat dissipation.

3 Vertical module mounted with 2 modules with


identical heat dissipation on both sides.

4 Horizontal module mounted with 2 modules with


identical heat dissipation on both sides.

Introduction:
page 68

Product selector, curves:


page 72

9
10
Characteristics:
pages 69 to 71

Dimensions, Wiring diagrams:


page 73

72
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Interfaces

Dimensions,
Wiring diagrams

Dimensions (mm):

For discrete signals

Slim solid-state interface modules

ABS2Sp02pp

74

74

ABS2E/ABS 2Sp01pp

78

78

9,5

70,5

70,5

75

75

17,5

Circuit diagrams

Solid-state input modules

548 V

4
5
6

A2

A1

A2

A1

A2

+A1

13

14

ABS2Epppp

14

+13

ABS2EApppp

14

+13

ABS2ECpppp

Solid-state output modules


5-24 V

5-24 V

5-24 V

5-24 V

A2

A1

A2

A1

A2

A1

A2

A1

7
8
14

13

14

13

14

13

14

13

14

13

14

+13

ABS2SA0pMB

ABS2SC0pEB

A2

ABS2SA0pMB

+A1

A2

+A1

ABS2SC0pEB

(1)
F

Resistive load

(1)

Inductive load

Resistive load

Inductive load

F: fuse DF1 SS133.2

10

(1) or peak limiter

Introduction:
page 68

Characteristics:
pages 69 to 71

Product selector, curves:


page 72

Dimensions, Wiring diagrams:


page 73

73
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Solid State Relays

Selection guide

SSR solid state relays

Applications

Panel mounted

Contact type

1 N/O SPST contact

1
2
3
4

Control voltage ranges

Operating voltages

Type of switching

Current

6
7

90280 V
332 V, 3.532 V

24280 V, 48530 V, 48660 V

0100 V

Zero voltage switching

DC switching

10, 25, 50, 75, 90, 125 A

12, 25, 40

Degree of protection

IP20

LED indication

Yes

Cooling

Thermal protection or with heat sink accessory

Solid state relay type

a
c

Page

SSRP
76

9
10

74
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

DIN rail mounted

1
2
3
1 N/O SPST contact
90280 V

90140 V

432 V

332 V

24280 V

Zero voltage switching

10, 20, 30 A

45 A

IP20

Yes

Built-in heat sink

SSRD

76

9
10

75
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Solid State Relays

Introduction,
description,
general characteristics

SSR solid state relays

Introduction

The SSR solid state relay range includes:


bb relays for panel mounting: SSRP.
bb relays for DIN rail mounting: SSRD.

1
1

2
3
5

Description

SSRP relays for panel mounting


1 2 x 4.9 holes for mounting.
2 Connection terminals.
3 Connection terminal screws.
4 Input voltage indicator LED, green.
5 Thermal interface which must be via the back of the product.

2
3
4
6

SSRD relays for DIN rail mounting


1 Lugs for plate mounting.
2 Built-in heat sink.
3 Connection terminals.
4 Connection terminal screws.
5 Input voltage indicator LED, green.
6 Bracket for mounting on 35 mm DIN rail.

6
General characteristics

SSRP solid state relays, panel mounting


Product certifications

UR E258297, CSA LR 40787, IEC 60950-1, IEC 62314

Product marking
Ambient air temperature
around the device

e
Storage

Operation

Encapsulation

- 40+ 125
Thermally conductive epoxy

Degree of protection

IP20 (with cover), IP00 (without cover)

Terminal screw torque

Nm

Inputs: 1.1 (screw: 3.5 / length 6 mm)


Outputs: 2.2 (screw: 4 / length 7.4 mm)

SSRD solid state relay, DIN rail mounting


Product certifications

UR E258297, CSA LR 40787, IEC 60950-1, IEC 62314

Product marking

- 40+ 80

Ambient air temperature


around the device

e
Storage

- 40+ 80

Operation

- 40+ 125

Encapsulation

Thermally conductive epoxy

Degree of protection

IP20

Terminal screw torque

1030 A relays

Nm

Inputs: 0.60.7 / Outputs: 0.60.7

45 A relays

Nm

Inputs: 0.60.7 / Outputs: 1.11.7

Max. wire size

1030 A relays

Inputs: 5.3 mm2 - AWG 10 / Outputs: 5.3 mm2 - AWG 10

45 A relays

Inputs: 3.3 mm2 - AWG 12 / Outputs: 8.4 mm2 - AWG 8

10
Introduction:
page 76

Characteristics:
pages 76 to 78

Product selector:
page 79

Dimensions:
page 80

Curves:
pages 80 and 81

76
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Zelio Solid State Relays


SSR solid state relays
Panel mounting

SSRP solid state relays, panel mounting


Relay type

Input specification

SCR output, Zero voltage switching

SSRPCDS10A1

SSRPCDS25A1

SSRPCDS50A1

Control voltage range


Maximum turn-on voltage
Maximum turn-off voltage
Maximum typical input current

cV
cV
cV
mA

332
3
1.0
10 at c 12 V

332
3
1.0
10 at c 12 V

332
3
1.0
10 at c 12 V

Operating voltage
Load current range
Transient overvoltage
Maximum surge current (16.6 ms)
Maximum On-state voltage drop at rated current
Thermal resistance junction to base plate
Maximum It for fusing (8.3 ms)
Maximum off-state leakage current at rated voltage
Minimum off-sate dv/dt at maximum rated voltage
Maximum turn-on time
Maximum turn-off time
Relay type
SCR output, Zero voltage switching

aV
A
Vpk
Apk
Vrms
C/W
Asec
mA
V/sec
Cycle
Cycle

24280
0.15 10
600
120
1.6
1.48
60
1.0
500
1/2
1/2
SSRPCDS75A2

24280
0.1525
600
250
1.6
1.02
260
1.0
500
1/2
1/2
SSRPCDS90A3

24280
0.1550
600
625
1.6
0.63
1620
1.0
500
1/2
1/2
SSRPCDS125A3

Control voltage range


Maximum turn-on voltage
Maximum turn-off voltage
Typical input current

cV
cV
cV
mA

332
3
1.0
10 at c 12 V

332
3
1.0
10 at c 12 V

332
3
1.0
10 at c 12 V

Operating voltage
Load current range
Transient overvoltage
Maximum surge current (16.6 ms)
Maximum On-state voltage drop at rated current
Thermal resistance junction to base plate
Maximum It for fusing (8.3 ms)
Maximum off-state leakage current at rated voltage
Minimum off-sate dv/dt at maximum rated voltage
Maximum turn-on time
Maximum turn-off time
Relay type
SCR output, Zero voltage switching

aV
A
Vpk
Apk
Vrms
C/W
Asec
mA
V/sec
Cycle
Cycle

48530
0.1575
1200
1110
1.6
0.31
4150
1.0
500
1/2
1/2
SSRPP8S10A1

48660
0.2590
1200
1350
1.7
0.28
6000
1.0
500
1/2
1/2
SSRPP8S25A1

48660
0.25125
1200
2000
1.7
0.22
12 700
1.0
500
1/2
1/2
SSRPP8S50A1

Operating voltage
Maximum turn-on voltage
Maximum turn-off voltage
Typical input current

aV
Vrms
Vrms
mA

90280
90
10
6 at 120 Vrms

90280
90
10
6 at 120 Vrms

90280
90
10
6 at 120 Vrms

Operating voltage
Load current range
Transient overvoltage
Maximum surge current (16.6 ms)
Maximum On-state voltage drop at rated current
Thermal resistance junction to base plate
Maximum It for fusing (8.3 ms)
Maximum off-state leakage current at rated voltage
Minimum off-sate dv/dt at maximum rated voltage
Maximum turn-on time
Maximum turn-off time
Relay type
Mosfet output

aV
A
Vpk
Apk
Vrms
C/W
Asec
mA
V/sec
ms
ms

24280
0.1510
600
400
1.6
1.48
60
10 max.
500
10 max.
40 max.
SSRPCDM12D5

24280
0.1525
600
600
1.6
1.02
260
10 max
500
10 max.
40 max.
SSRPCDM25D5

24280
0.1550
600
850
1.6
0.63
1620
10 max
500
10 max.
40 max.
SSRPCDM40D5

Control voltage range (input voltage)


Maximum turn-on voltage
Maximum turn-off voltage
Typical input current

cV
cV
cV
mA

3.532
3.5
1.0
1.6 (c 5 V), 28 (c 32 V)

3.532
3.5
1.0
1.6 (c 5 V), 28 (c 32 V)

3.532
3.5
1.0
1.6 (c 5 V), 28 (c 32 V)

Control voltage range


Load current range
Minimum load current
Maximum surge current (16.6 ms)
Maximum On-state voltage drop at rated current
Thermal resistance junction to base plate
Maximum off-state leakage current at rated voltage
On-state resistance
Maximum turn-on time
Maximum turn-off time

cV
A
mA
Apk
Vpk
C/W
mA

sec
msec

0100
12
0
28
1.6
1.34
0.2
0.13
100
1.0

0100
25
0
51
2.1
0.83
0.3
0.05
100
1.0

0100
40
0
106
2.1
0.83
0.3
0.05
100
1.0

Output specification

Input specification

Output specification

Input specification

Output specification

Input specification

Output specification

2
3
4
5
6
7
8
9
10

77
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Characteristics (continued)

Zelio Solid State Relays


SSR solid state relays

Panel mounting (continued)


DIN rail mounting

SSRP solid state relays, panel mounting (continued)

1
2
3

Relay type

SCR output, Zero voltage switching

SSRPP8S75A2

SSRPP8S90A3

SSRPP8S125A3

Input specification
Operating voltage

aV

90280

90280

90280

Maximum turn-on voltage

Vrms

90

90

90

Maximum turn-off voltage

Vrms

10

10

10

Typical input current

mA

6 at 120 Vrms

6 at 120 Vrms

6 at 120 Vrms

Output specification
Operating voltage

aV

48530

48660

48660

Load current range

0.1575

0.2590

0.25125

Transient overvoltage

Vpk

1200

1200

1200

Maximum surge current (16.6 ms)

Apk

1110

1350

2000

Maximum On-state voltage drop at rated current

Vrms

1.6

1.7

1.7

Thermal resistance junction to base plate

C/W

0.31

0.28

0.22

Maximum It for fusing (8.3 ms)

Asec

4150

6000

12 700

Maximum off-state leakage current at rated voltage

mA

10 max.

5 max.

5 max.

Minimum off-sate dv/dt at maximum rated voltage


Maximum turn-on time

V/sec 500
ms
10 max.

500
10 max.

500
10 max.

Maximum turn-off time

ms

40 max.

40 max.

40 max.

SSRD solid state relay, DIN rail mounting

4
5
6

Relay type

SCR output, Zero voltage switching

SSRDP8S20A1

SSRDP8S30A1

SSRDF8S45A1

Operating voltage

aV

90280

90280

90280

90140

Maximum turn-on voltage

Vrms

90

90

90

90

Maximum turn-off voltage

Vrms

10

10

10

10

Typical input current

mA

2 (120 Vrms),
4 (240 Vrms)

2 (120 Vrms),
4 (240 Vrms)

2 (120 Vrms),
4 (240 Vrms)

15 (120 Vrms)

Operating voltage

aV

24280

24280

24280

24280

Load current range

10

20

30

45

Transient overvoltage

Vpk

600

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

625

Maximum On-state voltage drop at rated current

Vrms

1.6

1.6

1.6

1.6

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

1620

Maximum off-state leakage current at rated voltage

mA

10

10

10

10

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500
ms
10 max.

500
10 max.

500
10 max.

500
10 max.

ms

40 max.

40 max.

40 max.

40 max.

SSRDCDS10A1

SSRDCDS20A1

SSRDCDS30A1

SSRDCDS45A1

Output specification

Maximum turn-on time


Maximum turn-off time
Relay type

SSRDP8S10A1

Input specification

SCR output, Zero voltage switching

Input specification
Control voltage range

cV

432

432

432

332

Maximum turn-on voltage

cV

4.0

4.0

4.0

4.0

Maximum turn-off voltage

cV

1.0

1.0

1.0

1.0

Typical input current

mA

812

812

812

17

Operating voltage

aV

24280

24280

24280

24280

Load current range

10

20

30

45

Transient overvoltage

Vpk

600

600

600

600

Maximum surge current (16.6 ms)

Apk

120

250

625

625

Maximum On-state voltage drop at rated current

Vrms

1.6

1.6

1.6

1.6

Maximum It for fusing (8.3 ms)

Asec

60

260

1620

1620

Maximum off-state leakage current at rated voltage

mA

10

10

10

10

Minimum off-sate dv/dt at maximum rated voltage

V/sec 500

500

500

500

Maximum turn-on time

Cycle

1/2

1/2

1/2

1/2

Maximum turn-off time

Cycle

1/2

1/2

1/2

1/2

Output specification

8
9
10

78
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Product selector

Zelio Solid State Relays


SSR solid state relays

Solid state relays, 1 N/O SPST contact

bb Panel mounting
Switching

Input

Voltage range
Output

Load
current
range

Catalog
numbers

Weight

c 332

a 24280

10

SSRPCDS10A1

0.113

25

SSRPCDS25A1

0.113

50

SSRPCDS50A1

0.113

a 48530

75

SSRPCDS75A2

0.113

a 48660

90

SSRPCDS90A3

0.113

125

SSRPCDS125A3

0.113

10

SSRPP8S10A1

0.113

25

SSRPP8S25A1

0.113

50

SSRPP8S10A1

0.113

a 48530

75

SSRPP8S75A2

0.113

a 48660

90

SSRPP8S90A3

0.113

125

SSRPP8S125A3

0.113

12

SSRPCDM12D5

0.113

25

SSRPCDM25D5

0.113

40

SSRPCDM40D5

0.113

10

SSRDP8S10A1

0.272

20

SSRDP8S20A1

0.272

30

SSRDP8S30A1

0.272

kg

SCR output
Zero voltage
switching
SSRPCDS25A1

a 90280

SSRDCDS10A1

a 24280

Mosfet output
DC switching

c 3.532

c 0100

bb DIN rail mounting


SCR output
Zero voltage
switching

SSRDCDS45A1

a 90280

a 24280

a 90140

a 24280

45

SSRDF8S45A1

0.482

c 432

a 24280

10

SSRDCDS10A1

0.272

20

SSRDCDS20A1

0.272

30

SSRDCDS30A1

0.272

45

SSRDCDS45A1

0.482

c 332

a 24280

Accessories for panel mounted relays


Description

SSRAH1

For use
with 1050A relays (1)

Catalog
numbers

Heat sink

SSRPP8Spppp,
SSRPCDSpppp,
SSRPCDMpppp

SSRAH1

0.487

Thermal interface
Sold in lots of 10

SSRPP8Spppp,
SSRPCDSpppp,
SSRPCDMpppp

SSRAT1

0.011

2
3
4
5
6
7
8

Weight
kg

(1) for load current range 75, 90 and 125 A relays, please contact your Customer Care Center.

10
SSRAT1
Introduction:
page 76

Characteristics:
pages 76 to 78

Product selector:
page 79

Dimensions:
page 80

Curves:
pages 80 and 81

79
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Solid State Relays

Dimensions,
curves

SSR solid state relays

Solid state relays, 1 N/O SPST contact


Solid state relays SSRP

Thermal interface SSRAT1


45,5

35,5

23,6

4,6

23,6

47,2

42,4

(1) 4,9 0,25 hole

Heat sink SSRAH1


Heat sink dissipation curve

114,3 0,5
4,6 0,25

Thermal resistance (C/W)

47,6 0,5

57,9

4,6 0,25

M4

57,9

120,6

M4
115,8

47,7
55,1

58,4

(1)

47,6 0,5

bb Panel mounting

1,0
0,9
0,8
0,7
0,6
0,5
0,4
0,3

20

40

60

80 100 120 140


Dissipation (W)

66

0,2

6
4,6 0,25

115,8 0,5

4,6 0,25
114,3 0,5

120,6

139,7
45 A relays

4,4

76,2

98,8

(1)

80

(1)

89,7

4,4

87,4

1030 A relays

98,8

bb DIN rail mounting

(2)

13,15

11,2

(2)
22,5

10

22,6
45,5

97,7
106,7
(1) 35 mm DIN rail. (2) 4.4 x 5.5 elongated hole
Introduction:
page 76

Characteristics:
pages 76 to 78

(1) 35 mm DIN rail. (2) 4.4 x 5.5 elongated hole


Product selector:
page 79

Dimensions:
page 80

Curves:
pages 80 and 81

80
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Zelio Solid State Relays

Curves

SSR solid state relays

Thermal derating curves

bb Panel mounting SSRP relays


vv SCR output

115

120

10

20

40

60

110

15

(1)

5
0

80

120
5

10

15

20

Load current (Arms)

Max ambient temperature


(C)

(1) No heat sink

25

20

40

60

Base plate temperature (C)

95

0,5C/W 0,3C/W
100

80

1C/W

110

40

15

30

45

60

75

20

40

60

95
0,5C/W

0,2C/W
0,4C/W

80

100

1C/W
110

120

Load current (Arms) Max ambient temperature


(C)

20

100

2C/W

110

(1)
10

20

30

40

Load current (Arms)

50

20

40

120

60

40

60

80

Load current (Arms)

20

40

60

160

80

90

0,5C/W

100
80

1C/W

110

40
120
0

Max ambient temperature


(C)

0,4C/W
0,2C/W

120

30

60

90

120

Load current (Arms)

20

40

60

16

100

4C/W

12

6C/W

110

(1)

4
0

10

12

20

40

90
0,2C/W
0,5C/W
60

1C/W

80

Load current (Arms) Max ambient temperature


(C)

(1) No heat sink

100

1,5C/W
2C/W

30

120
60

80

120

(1)
0

16

24

32

Load current (Arms)

40

20

40

60

140

Base plate temperature (C)

2C/W

20

Power dissipation

90

Base plate temperature (C)

Power dissipation

25 and 40 A relays

24

80

Max ambient temperature


(C)

vv Mosfet output
12 A relays

80

Max ambient temperature


(C)

125 A relays

120

90

(1) No heat sink

40

80

40

20

80

120
0

1C/W 0,5C/W
1,5C/W

Max ambient temperature


(C)

90 A relays

120

60

(1) No heat sink

75 A relays
Power dissipation

20

Base plate temperature (C)

Load current (Arms)

3C/W 2C/W

10

Power dissipation

100

Base plate temperature (C)

(1)

95
1C/W

25

Base plate temperature (C)

5C/W

30

Power dissipation

9C/W

110

Power dissipation

3C/W

7C/W

50 A relays
Base plate temperature (C)

12

Power dissipation

25 A relays
Base plate temperature (C)

Power dissipation

10 A relays

5
6

80

Max ambient temperature


(C)

(1) No heat sink

bb 5 Rail mounting SSRD relays

Output current (Arms)

1045 A relays
45 A

45

40
35
30

30 A

25
20

20 A

15
10

10 A

5
0

20

40

60

80

Ambient temperature (C)

10

81
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

8001 Knightdale Blvd.


Knightdale, NC 27545
Tel: 919-266-3671
19 Waterman Avenue
Toronto, Ontario M4B 1Y2
Tel: 416-752-8020

The information provided in this documentation contains general descriptions and/or technical
characteristics of the performance of the products contained herein. This documentation is not
intended as a substitute for and is not to be used for determining suitability or reliability of these
products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.
Please note: not all parts listed in this catalog are available in all countries.
Design: Schneider Electric
Photos: Schneider Electric

ART. 960361

2010 Schneider Electric. All rights reserved.

06/2010

DIA3ED2090304EN-US

http://www.schneider-electric.us/

Schneider Electric USA Inc.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2010

Electromechanical and solid-state Zelio Relays


Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Anda mungkin juga menyukai