1) Define Proportional Band

2) What do you mean by PID? (PROJECT INSPECTION DEPARTMENT )


3) What is use of Integral (reset) expressed in repeat/ minute or minute / repeat
in control system? Explain the effect of integral action when integral time is
gradually decreased?
4) Which is more sensitive?
a) 60%PB
B) 20%PB
C) 100%PB
5) Which is more sensitive?
a) Kbar a gain of 3
b) Kbar a gain of 0.5
c) Kbar a gain of 1.0
6) What is Intrinsic Safety?
7) Draw a simple Whetstone Bridge Circuit?
8) Explain the effect of derivative action when only the derivative time is
gradually increased in PID Control/
9) Explain Flashing in control valves?
10)
Name 3 types of Level Measurement:
11)
Name 3 types of Control valves:
12)
Name 5 Instrument Makers you have been working with?
13)
What is the purpose of positioner in the control valve?
14)
Give the appropriate output in milli Amps if the instrument has the
input range of 3 to 15 PSI.
a) 3PSI-____4____ b)
9PSI-___12_______
c) 12PSI-____16______
15)
If the pressure input range is 0-80 PSI. Give the corresponding output
pressure in the 3-15 PSI range.
a)_______ 3 PSI
b)_________ 12 PSI
c)_________ 14 PSI
16) Give 3 types of Thermocouples:
17) What does 85 PSIG mean in Absolute Pressure?
18) Fill in the blanks:
a) The standard signal of electronic instruments in our plant varies from 420 mA DC, where 4 mA DC stands for _0____% and 20 mA DC stands for ___100__%
of the signal range.
b) Then, the standard signal for;
10% is __________ mA DC
25% is ______8____ mA DC
50% is _____12_____ mA DC
d) The measuring range of PIC-WE3POOI is 0 to 3 bar. Then the transmission
signal of the electronic transmitter is:
4 mA DC for _____0_____bar

20 mA DC for ____3______bar
Then the signal is:
__________ mA DC for 1.0 bar
__________ mA DC for 1.5 bar
__________ mA DC for 2.4 bar
e) The standard signal of pneumatic instrument in our plant varies from 0.2
to 1.0 bar, where 0.2 bar stands for _______% and 1.0 bar stands for
_______%
Then the signal for;
10% is __________ bar
20% is __________ bar
50% is ____0.6______ bar
f) For the failure close type control valves, the control signal is usually 0.2
bar for ___________ opening (fully closed) and 1.0 bar for __________
opening (fully open).
___________ bar for 10% opening.
___0.4________ bar for 25% opening.
____0.6_______ bar for 50% opening.
g) For the failure open type control valves, the control signal usually 0.2 bar
for ___________ opening (fully open) and 1.0 bar for __________ opening
(fully close).
Then the signal for;
___________ bar for 10% opening.
___________ bar for 25% opening.
___________ bar for 50% opening.
19) What do you meant if you get signal from 4-20 mA DC is only 0 mA DC.
20) What is the difference between hysteresis and linearity?
21) What is the feedback system?
22) What is the resistance of industrial RTD at 0 deg. C?
23) What is cascade control?
24) What is decibel?
25) What is linear amplifier?
26) What is the difference between gauge pressure and absolute pressure?
27) What is the relationship between gain and proportional?

28) What is the relationship of a direct acting controller, between measured


variable and output?
29) Draw the diagram of a zener barrier.
30) Draw three wire RTD using whetstone bridge.
31) Explain the cavitation of control valves.
32) What are the two properties of H2S?