Anda di halaman 1dari 55

Service Manual

Split System Air


Conditioner
Model: DSB-F074LH

Caution
: In this Manual, some parts can be changed for improving,
their performance without notice in the parts list. So, if you
need the latest parts information,please refer to PPL(Parts
Price List) in Service Information Center (http://svc.dwe.co.kr).

DAEWOO ELECTRONICS CO., LTD.

1. SPECIFICATIONS
MODEL

DSB-F074LH

ITEM
Function

Cooling & Heating

Class

T1

Power

AC 220~240V/ 50Hz

Capacity

2,050

Btu/h

7,000

l/h

1.0

Running Current

3.1/3.3

Power Input

680/720

Dehumidification
Electrical
Data

Compressor

Type

Rotary

Model

G4C072JU1ER (Samsung)

Capacitor

30F / 450VAC

Division
Fan
Motor

Indoor Unit

Outdoor Unit

Type

Cross flow fan

Propeller fan

Capacitor

1.0F 400VAC

1.8F 400VAC

YDK-8-4B

YDK-30-68

Motor Model Number


Sound Level (Hi)

dB(A)

39

48

Fan Speed (Hi)

RPM

1,350

850

Refrigerant
(R-410A)

Control
Charge Q'ty

Capillary
g

730

Type

Flare

Connection
OD (Liquid/Gas)
Dimensions (W x H x D)
Net Weight

in(mm)

1/4 (6.35)

3/8 (9.52)

mm

750 x 245 x 179

654 x 549 x 256

kg

7.0

34

2. OUTLINE AND DIMENSIONS


1 INDOOR UNIT
DSB-F074LH

750

Connecting Pipe

Plate Mounting

REMOTE CONTROLLER

REMOCON

Grille Insert

245

Frame Grille

Body

179

Plate Mounting

INSTALLING THE INSTALLATION PLATE


DSB-F184, 244 LH/PH/AH
DSB-183LH/183LH-R/240LH-R, DSA-183LH-R/240LH-R
90

Indoor Unit

Installation Plate

50

Wall Hole (65)

80

460

400

140

40

40

Indoor Unit

17

DSB-F154LH/PH/AH
DSB-182LH

Installation Plate

40

Wall Hole (65)

121

385

385

121

DSB-F094, 124 LH/PH/AH


DSB-123LH/093LH
97

Indoor Unit
Installation Plate

40

Wall Hole (65)

53

355

285

122

INSTALLING THE
PLATE. DSB-F074LH
INSTALLATION
DSB-070LH/071LH/091LH/092LH
184

Indoor Unit

35

Installation Plate

Wall Hole (65)


50

325

235

12

140

Unit : mm

2 OUTDOOR UNIT
DSB-F074LH

Inlet

Outlet

Foot Cushion

Inlet

Outlet

Cabinet Front

SVC Cover

Servise Valve

Cabinet Side Panel Top Guide Support

3. OPERATION
1 NAME AND FUNCTION OF PARTS
Indoor Unit
DSB-F074LH

Deodorizing Filter

Electrostatic Filter

Removes bad smells


from the air.

Removes dust
particles from the air.

Electric Dust Collector


(Air clean Plasma)
Removes small dust and
generates (-) ions.
(PH/AH Model Only)

Air In
Indoor Cover

02 Hose Cover
(AH Model Only)

Nano Silver Filters


Removes dust and
prohibits germs.

Sensor Wire
Connection Cover

Fan Direction
(Up/Down)

Cold Air

Remote
Sensor

Remove cover to access


the AC connection from
this unit to the outdoor unit.

Indicators
Indicate the setting

Power Plug
LCD Remote Controller

Outdoor Unit
DSB-F074LH

Connection Cover
AIR IN

Remove cover to access the


AC connection
to the indoor unit.

Connection Wire
O2 Hose Wire
(AH Models Only)

AIR OUT

Connection Pipes

Drain Hose

Service Valves
The indoor and outdoor units
are connected by copper tubes
which are connected here.

2 REMOTE CONTROLLER
Name of Each Button
DSB-F074LH

Display
Display information

AUTO

ON/OFF Button
Press to turn the unit
on or off.
FAN SPEED Button
Press to select the fan speed
(High " ", Middle " ", Low " ",
Natural).
MODE Button
Press to cycle through the modes
(Auto/Quick/Cool/Fan/Dehumidifier/
Heat)
SLEEP Button
Press to set the unit for the sleep
mode.

MODE

FAN SPEED

FAN DIR.

SLEEP

TEMPERATURE Buttons
Press to raise or lower
the desired temperature.
FAN DIR.
Button
Press to select up/down
direction for fan.

TIMER

ON/OFF

ENTER/
CANCEL

TURBO/MILD

TURBO/MILD
Press to select super power
operation (Turbo) mode.

TIMER ON/OFF Button


Press to set the unit off or on time.
(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8,
10, 12, 16, 20, 24hr)
TIMER ENTER/CANCEL Button
Press to enter a timer setting or
to cancel timer setting

COVER
Slide down to access most
of the remote buttons.
Slide down further to
access the battery
compartment.

MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)


Light to indicate the mode selected.

AUTO
FAN Indicators
Light to indicate
the fan speed.

FAN DIRECTION Indicators


Light to indicate the
fan direction.

NATURAL Indicator
Light to indicate the
speeds simulating a breeze.

TIMER Indicators (Include sleep)


Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicators
Light to indicate the temperature or time.

3 DESCRIPTION OF FUNCTIONS
OFF-Timer
If you set time in OFF-Timer Mode, the unit will stop at the set time.

ON

Unit ON
Unit OFF

OFF

SET Time

HOUR

ON-Timer
If you set time in ON-Timer Mode, the unit will run at the set time.

Unit ON

ON
OFF

Unit OFF

SET Time

HOUR

Control of Room Temperature


(1) Range of setting temperature: 18~32C
(2) Setting temperature: Operating temperature of compressor
COMP (ON)

COMP (OFF)
COMP (ON)

COMP (OFF)

-1C

+1C
0C

-1C

(RT-DT)

+1C
0C

(RT-DT)

HEATING

(COOLING)

*RT: ROOM TEMPERATURE


DT: DESIRED TEMPERATURE

(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of room
temperature.

Buzzer
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,
beep".
(1) In the case of receiving ON/OFF signal-"beep" "beep"
(2) And so on-"beep"
9

Fan Speed (Indoor Unit)


(1) Motor speed (high speed, middle speed, low speed).
(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)
(3) Relation of operating mode between fan speed.
FAN ONLY

DEHUMI-

COOL

AUTO

QUICK

HEAT

DIFICATION
H

Auto

Auto

Auto

Auto

Natural

Natural

Natural

Natural

Natural

(4) Automatic Operation


If the unit is set in 'AUTO' mode, the unit operates automatically according to the room temperature to keep the
room temperature comfortable.

(COOLING)
H
M
L
0C

1C

2C

(R.T-D.T)

(HEATING)
H
M
L
0C

1C

10

2C

(DT-RT)

Indoor Fan Motor RPM for each Models


MODEL
F074
F094
F124
F154
F184
F244

MODE

Turbo

High

Mid

Low

Ultra low

Monitoring

COOL

1360

1350

1290

1060

910

HEAT

1230

1120

1060

820

500

COOL

1280

1250

1150

990

840

HEAT

1120

1020

970

800

500

COOL

1290

1260

1150

970

840

HEAT

1300

1220

1070

910

500

COOL

1390

1380

1320

1020

940

HEAT

1350

1260

1090

910

500

COOL

1280

1260

1170

1020

900

HEAT

1150

1050

1000

870

500

COOL

1280

1260

1170

1020

900

HEAT

1260

1170

1020

900

500

Sleep Mode
(1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature.
(The unit will not operate after 4 hour)
(2) For changing the temperature.
DT

DT

+0.5C
+0.5C

0.5C

+0.5C

0.5C
0.5C

0.5

1.0

HOUR

(COOLING CYCLE)

0.5

1.0

HOUR

(HEATING CYCLE)

(3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP
indicator will disappear in the display.

Emergency Operation
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can be
used to run the unit.
(2) The setting conditions of Emergency operation are as follows.
Operation mode: Quick
Preset temperature:18C: Cooling, 32C: Heating)
Fan speed: High
* You cannot operate with remote controller.
11

Frost Prevention of Indoor Unit


When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil
temperature is lower than 0C at the end of 10 minutes of continuous compressor operation from the start, the
microcomputer of the unit stops the compressor to protect the unit from the frost. The control procedure for
indoor coil freeze protection.
1) The compressor and outdoor fan turn off.
2) Indoor fan operates according to user set speed.
3) The normal operation returns when the indoor coil
temperature is higher than 7C or equal to 7C.

Compressor and
Outdoor Fan

ON

ON
OFF
Set speed

Indoor Fan
-1C

+7C

(Indoor coil temperature)

3 min. Time Delay of Compressor


In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
power up.

Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selecting
operating Mode according to the room temperature
(RT: Room temperature)
ROOM TEMPERATURE

OPERATING MODE

FLAP POSITION

> RT
DT-2C RT DT+3C
DT+3C < RT

Heating

Heating Position

Dehumidifier

Cooling Position

Cooling

Cooling Position

DT-2C

(2) Selecting Operating Mode Again


Room temperature meets desired temperature and the compressor stops running over 30 minutes, then the unit
selects operating Mode again.

12

Dehumidification Mode
1 Desired temperature < Room temperature

Outdoor Fan, Compressor : ON


Indoor Fan : Low speed
2 Desired temperature Room temperature
Compressor : 3 min/ON, 5 min/OFF
Fan Speed : low speed
3 Room temperature 18C
Compressor : OFF
Fan speed : Low speed

Air Discharge Direction(only remocon operation)


The air discharge direction procedure is below.
Fixed

Up/Down

Fixed

Up/Down
COOLING POSITION

Quick Mode(Powerful Cooling & Heating)


1) Cooling Mode
* When the room temperature is higher than 22C
1 Fan Speed: Super high speed
2 Air discharge direction: Fixed
3 Set temperature: 18C (Fixed)
4 Compressor and Outdoor Fan
The air discharge direction procedure is below
Fixed
Up/Down

HEATING POSITION

1) Heating Mode
* When the room temperature is higher than 22C
1 Fan Speed: Super high speed
2 Air discharge direction: Fixed
3 Set temperature: 18C (Fixed)
4 Compressor and Outdoor Fan
The air discharge direction procedure is below

Up/Down

Fixed

Fixed

Up/Down

* The option is LEFT/RIGHT direction.

Up/Down
Fixed

* The option is LEFT/RIGHT direction.

13

Defrost Function Chart for Outdoor Condenser


Start

Return

Comp

4 Way

OD Fan

ID Fan
40sec
*Note1

6sec

15min
*Note2

40sec

6sec

Note1 : 120sec for 24kBtu Model


Note2 : The Temperature is over 120C or 15 minute later.

Max Load Heating Operation Diagram


Temperature (Indoor Evaporator)

60C
57C
49C
38C

ID FAN

* Note1
Monitoring
"Ultra Low"

Set Value
"Hi, Mid, Low"

OD FAN

"Hi"

"Hi"

OFF *Note2

COMP

OFF *Note3

Note1 : 30s ON. 120s OFF when the Compressor is OFF.


Note2 : The Fan is ON when the temperature is below 49C.
Note3 : The Temperature is over 60C and 1 minute later.
14

Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
(1)Error Code Display Pattern
1 ON LAMP: Blink
LED BLINK PATTERN

CASE

NOTE

Room Sensor open or Short

Continuously woorking to fix room


temperature 32C in heating mode

0.5s
8s

I/D coil sensor open or short


1 times blink

Do not woorking

O/D coil sensor open or short


Compressor or electrical parts
of compressor error.

2 times blink

Continuously woorking to fix room


temperature 18C in cooling mode.

Continuously workiug

Gas leak

Self Diagnostic Function Description


1. Sensor Error
Open or Short circuit of Sensors, Room, Indoor Coil Sensor and Outdoor Coil Sensor
Open : Micom, Input Voltage 0~0.3V, Short: Micom, Input Voltage 4.7~5.0V
2. Compressor Error
At the start operation, the Compressor is ON and 5 Minutes later, the Temperature change value of Indoor
Coil is below +/-2C.
Emergency Mode Operation detect only
3. 4 Way Valve Error
At the start operation, the Compressor is ON and then.
Indoor Coil Temperature goes up to 2C in Cooling Operation Mode
Indoor Coil Temperature goes down to 2C in Heation Operation Mode

15

4. WIRING DIAGRAM
Indoor Unit

Indoor Unit

DSB-F094, 124LH

DSB-F094, 124PH

40

Outdoor Unit

Outdoor Unit DSB-F074LH

DSB-F094, 124AH

DSB-F154, 184 LH/PH

DSB-F154, 184AH

DSB-F244LH/PH

43

5. REFRIGERANT CYCLE
[Heat Pump Mode]

Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.

18

2 Table of Suction Pressures according to the


change of Outdoor Room Temp.

MODEL

DSB-F074

REFRIGERANT

730g

INDOOR ROOM

OUTDOOR ROOM

TEMP.(DB/WB, C) TEMP.(DB/WB, C)

27.0/19.0

LH/AH

DSB-F094

900g

27.0/19.0

LH/PH/AH

DSB-F124

1,000g

27.0/19.0

LH/PH/AH

DSB-F154

1,150g

27.0/19.0

LH/PH/AH

DSB-F184

1,200g

27.0/19.0

LH/PH/AH

DSB-F244

1,750g

27.0/19.0

LH/PH/AH

SUCTION PRESSURE
Bar (gage)

kPa, (gage)

25.0 /

8.3

830

30.0 /

8.7

870

35.0 /

9.1

912

40.0 /

9.2

925

45.0 /

9.7

970

25.0 /

8.5

850

30.0 /

8.9

890

35.0 /

9.3

932

40.0 /

9.4

945

45.0 /

9.9

990

25.0 /

7.6

760

30.0 /

8.0

800

35.0 /

8.4

843

40.0 /

8.6

860

45.0 /

9.0

900

25.0 /

8.0

800

30.0 /

8.4

840

35.0 /

8.8

883

40.0 /

9.0

900

45.0 /

9.4

940

25.0 /

7.6

760

30.0 /

8.0

800

35.0 /

8.4

840

40.0 /

8.6

860

45.0 /

9.0

900

25.0 /

7.6

760

30.0 /

8.0

800

35.0 /

8.4

840

40.0 /

8.6

860

45.0 /

9.0

900

NOTE)
1) These experiments are processed on the condition of the fixed indoor room TEMP.( DB: 27.0C, WB: 19.0C)
2) It takes at least ten minutes for the change of suction pressure to be steady-state, after Air conditioner operates
3) To analyze accurately whether refrigerant of Air conditioner leaks or not, you have to check not only suction
pressure but also discharge and suction temperature of compressor
4) These data can be changed slightly according to the temperature of environment or each set(Air conditioner)

19

3 R410A & R22 SATURATION PRESSURE TABLE


R410A
Temp (C)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

PRESSURE(LIQUID): bar
7.991
8.248
8.511
8.781
9.057
9.339
9.628
9.924
10.23
10.54
10.85
11.18
11.51
11.85
12.19
12.54
12.9
13.27
13.65
14.03
14.43
14.83
15.24
15.65
16.08
16.52
16.96
17.41
17.87
18.34
18.83
19.31
19.81
20.32
20.84
21.37
21.91
22.46
23.02
23.59
24.17
24.76
25.37
25.98
26.61
27.24
27.89
28.55
29.23
29.91
30.61
31.32
32.04
32.78
33.53
34.29
35.07
35.86
36.67
37.49
38.33

PRESSURE(VAPOR): bar
7.967
8.223
8.486
8.754
9.029
9.311
9.599
9.894
10.2
10.5
10.82
11.14
11.47
11.81
12.15
12.51
12.87
13.23
13.61
13.99
14.38
14.78
15.19
15.61
16.03
16.47
16.91
17.36
17.82
18.29
18.77
19.26
19.76
20.26
20.78
21.31
21.85
22.4
22.95
23.52
24.1
24.69
25.3
25.91
26.53
27.17
27.82
28.48
29.15
29.84
30.53
31.24
31.97
32.7
33.45
34.22
35
35.79
36.59
37.42
38.25

20

R22
PRESSURE: bar
4.98
5.144
5.312
5.484
5.661
5.841
6.026
6.215
6.409
6.607
6.809
7.017
7.229
7.445
7.667
7.893
8.124
8.361
8.602
8.848
9.1
9.357
9.619
9.887
10.16
10.44
10.72
11.01
11.31
11.61
11.92
12.23
12.55
12.88
13.21
13.55
13.89
14.24
14.6
14.97
15.34
15.71
16.1
16.49
16.89
17.29
17.7
18.12
18.55
18.99
19.43
19.88
20.33
20.8
21.27
21.75
22.24
22.74
23.24
23.75
24.27

6. CONTROL BLOCK DIAGRAM


DSB-F074LH

Unit on lamp

Remote

Air clean lamp

Emergency

Operating Mode

Signal
receiver

Fan Speed
Timer Selection

Quick lamp

Flap Position

Operation

Timer lamp

Temp. Setting
ON/OFF
Room air temp.

SLEEP

Indoor coil temp.

REMOCON

* Outdoor coil
temp

Circuit for signal receiver


A/D converter
Beeper

Stepping
motor

lnitialization
MICRO
CONTROLLER

Clock generation
DC5V
DC power supply

circuit for
motor driving

SMPS

AC220V
50Hz

DC12V
STEPPING MOTOR
ON/OFF

COMPRESSOR
ON/OFF

Circuit for
relay driving

Circuit for
TRIAC control

Relay RL3

Relay RL2

Relay RL1

TRIAC

* 4 way
valve

* Outdoor
fan motor

Compressor

Indoor fan
motor

* : Heat Pump Model Only

21

7. TROUBLE SHOOTING
Is the unit
display
mormal?

YES

NO

NO

check the failure


code according to
the self-diagonostic
(note 2)

Is the
unit display
normal?
YES

Outdoor unit does


not run?(note. 1)
YES

Does
the compressor run
normally?
YES
Indoor unit does
not run(note 1)
YES
Check the failure
code according to
the self diagnostic
(note 2)

NO

NO

Normal

check the
connecting
point of
magnetic
contactor

NO

Trouble

Is the power
applied to the
unit
YES

Is the
power normal?
check the voltage between
L & N of terminal
block
YES

press the power ON/OFF


button on remote controller
YES

Does the
beeper beep two
times?
YES

Is the display
all off?
YES

Check the connector on display


PCB connected to control PCB
Check the display PCB itself

NO

NO

NO

NO

Check power supply mains


or interconnection wires

Check the wiring of indoor

Is the
switch position
on switch pannel at
"Remote"
YES

YES

Does
control PCB
status LED repeat one
second "on and
off"?
control PCB fault
Micom or reset
IC fault

NO

Check the remote signal receiver


Check the connection between signal
receiver and control PCB

Place the switch


position to the
"Remote" and then
Check it once
more

22

Note 1)
1 Neither indoor unit nor outdoor unit runs.
Check the following points first. (There are following case in normal operation)
a. Is the timer mode set the "timer ON".
b. Is the timer mode set the "timer-OFF" and the time had passed?
2 Neither outdoor fan nor compressor runs while indoor fan runs.
Check following points first. (There are following cases in normal operation)
a. Is the temperature set point suitable?
b. Has the 3 minutes time guard for compressor operated?

Self-Diagnostic Function
Error Code
1 When the compressor do not run.
i) Check the voltage between L and Y of terminal block.
(Indoor Unit, Outdoor Unit)
ii) Check connecting wire of indoor unit and outdoor unit.
iii) Check relay RL1 on power P.C.B
2 Check fixing of indoor coil thermistor.
3 Check the GAS LEAKAGE of the pipe.

23

Neither Indoor Unit nor Outdoor Unit Runs


Confirm following statement.
When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.
1 Check the function select switch. Is it timer mode?
2 The function select switch locate the sleep mode and is the setting time over?
3 Is the setting mode DEHUMIDIFIER mode?
4 When the unit is DEHUMIDIFIER mode while in the auto mode, the outdoor unit and indoor unit does
not run.

The power is applied to the unit

Rating voltage
Check the voltge between L and
Y of terminal block

under 90%

Check the
Breaker or Fuse

Rating voltage more than 90%


No

Check the indoor unit display


is the display all off?

Yes
Press the ON/OFF switch of
Remote Control

No
Self Diagnostic
function is ON
Yes

No

Check according to
self Diagnostic function

Is the indoor unit display all off?

Control P.C.B defect

Pull out the power plug


and then insert the power plug
after 5 second

Control P.C.B is normal


Recheck from the beginning

24

Outdoor Unit Runs but Indoor Fan does Not Run


Check rotation of indoor fan

NO

Check the Fan Motor


bearing and fan

Rating voltage

Check the power P.C.B.

Rotate indoor fan by hand


YES
Check input Voltage of Fan
Motor connector at power P.C.B

under 90%

The circuit for triac control

Rating Voltage more than 90%


Open or short
Check the winding resistance of
Indoor unit fan motor

Change of fan motor

Normal
Check the fan motor capacitor

Check the connecting wire of


indoor fan motor

Run again

No

Check the starting of indoor fan motor

Run again

25

Normal

Outdoor Fan and Compressor Do Not Run


Confirm following statement.
When the unit operate normally, Sometimes the outdoor unit and indoor unit cannot operate.
1 Is the setting temperature proper?
2 Is the unit during 3min. Time delay of compressor.
3 During frost prevention of lndoor unit.
4 During dehumidifier mode.

Rating voltage

Check the voltge between L and


Y of indoor unit terminal

under 90%

Rating voltage
Check the voltge between L and
Y of outdoor unit terminal

under 90%

Check compressor,
outdoor fan motor individually

26

Check the wiring


and voltage
within doors

Check the
connecting wire

Only Compressor does not Run


- Check the following at cooling mode
Rating voltage

Check the voltge between L and


Y of indoor unit terminal

less than 90%

Check the control P.C.B


the circuit for relay
driving.

Rating voltage more than 90%


Rating voltage
Check the voltge between L and
Y of outdoor unit terminal

less than 90%

Check the connecting


wire between indoor
and outdoor.

Rating voltage more than 90%


Check the wiring of outdoor unit

Check the compressor


(Check the winding resistance)

NG

Change the control


P.C.B

Open or Short

Change the
compressor.

OK
Check the compressor capacitor

O2 Generator/Plasma Clean System Trouble Shooting


1. Both of the two system is switched by RL4 (on the POWER PCB) only.
2. If some trouble occurs, check the RL4 and around its wiring.
3. No problems in the PCB and Witing, check the Generator system or Plasma system.
Remote
Operation

RL4
Turn ON

O2 Generator
Motor
High Volt
Generator

27

O2 (AH Model Only)

High Volt (PH Model Only)

8. PCB DRIVING DESCRIPTION


1 PCB CIRCUIT DIAGRAM
DSB-F074LH

28

DSB-F074LH PART LIST (INDOOR UNIT)


Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
PART NAME

SPEC

QTY

LOCATION

USE

250V 50T 3.15A

FUSE

FUSE CLIP

AFC-520

FUSE

VARISTOR

15G561K

VAR

WAFER

YW396-05AVD

CN2

WAFER

YW396-03AVD

CN1

C-CERA

104Z,50VDC

CC1,2,5,6,7

C-CERA

103Z,50VDC

CC3,4,9,10,11,12

C-MULTI

104Z,CR0561B-Z5U

CC8

C-ELEC

470uF 35V SD

CE1

C-ELEC

10uF 450V SD

CE3,CE4

C-ELEC

100uF 16V SD

CE2

C-ELEC

10uF 16V SS

CE5

C-ELEC

4.7uF 50V SS

CE6

C-ARRAY

F3 104Z

CA3

C-ARRAY

F4 104Z

CA2

C-ARRAY

F5 104Z

CA1

RESISTOR

1/4W-12.7KF

R27,28,29

RESISTOR

1/4W-1KJ

21

R5,12,13,14,15,16,17,18,19,20,
R21,23,30,31,32,33,34,35,36,37,43

RESISTOR

1/4W-10KJ

R11

RESISTOR

1/4W-5.6KJ

R22

RESISTOR

1/4W-330J

R24,25,26

RESISTOR

1/4W-100J

R1,R4

RESISTOR

1/4W-68KJ

R8,R9

RESISTOR

1/4W-51KJ

R6

RESISTOR

1/4W-2KJ

R7

RESISTOR

1/2W-1KJ

R2

RESISTOR

1W-47J

R3

RESISTOR

1/4W-3.24KF

R41

RESISTOR

1/4W-49.9KF

R40

RESISTOR

1/4W-32.4KF

R38

RESISTOR

1/4W-24.9KF

R39,42

RESISTOR ARRAY

4A 103J

RA3

RESISTOR ARRAY

5A 103J

RA2

RESISTOR ARRAY

6A 103J

RA1

PIN

GP881205-2(187)

CN4

C-LINE ACROSS

275V 104K

CL1,CL2

WAFER

YFW800-01D

CN3

WAFER

SMAW250-06(WHITE)

CN6

WAFER

SMAW250-08

CN5

WAFER

YMAW250-04

CN7

WAFER

YMAW250-02

CN8

DIODE

1N4007 TAPE

D3

29

PART NAME

SPEC

QTY

LOCATION

DIODE

UF203

D2

DIODE ZENOR

1N5241B

ZD1

DIODE

ST01D-200

D1

C-CERA

2200pF, 250V

CY1

CHOKE COIL

1mH, 0.5A

L1

FILTER EMI

0.6*10*3TURN

L2

BUZZER

BM-20K

BZ1

COIL

130uH, 3A

L3

IC REGULATOR

KIA7805P

IC3

TR

KRC102M

TR1

IC RESET

KIA7042P

IC5

RELAY

US11-12S

RL3

RELAY

UKH-12S

RL1

SW TRANS

264P,1916

TRS1

CAPACITOR

1uF,400VAC

CAP1

PCB CONTROL

162.5X140X1.6T

PCB

IC SWITCHING

TNY264P

IC2

DIODE BRIDGE

S1NB80

BD1

TRIAC

SM3JZ47

T1

PHOTO COUPLER

TLP560J

PT1

IC DRIVE

TD62004AP

IC4,IC6

RESONATOR

CST8.00MGW

OSC

IC MICOM

TMP87C846AN

IC1

PHOTO COUPLER

TLP421

PC1,PC2

30

R-OPT. DETAIL LIST


COOL HIGH

COOL LOW

HEAT HIGH

HEAT LOW

MONITORING

R41

R39

R40

R38

R42

3.24

24.9

49.9

32.4

24.9

COOL HIGH

COOL LOW

HEAT HIGH

HEAT LOW

MONITORING

R28

R30

R29

R31

R27

3.65

22.6

32.4

36.5

22.1

COOL HIGH

COOL LOW

HEAT HIGH

HEAT LOW

MONITORING

R33

R35

R34

R36

R37

DSB-F184LH/PH/AH

5.76

12.4

32.4

22.1

22.1

DSB-F244LH/PH/AH

5.76

12.4

5.76

12.4

22.1

MODEL

DSB-F074LH

MODEL

DSB-F154LH/PH

MODEL

85

LED PCB ASS`Y


No

PART CODE

PART NAME

CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV
SW1

CDXE1H104M
3108804800
3103002700
DDLS05031D
DDLG05031D
DDLS05031D
DDLY05031D
3104398201
1TSP1838YA
5S40202000

C-MULTI
WAFER
HOLDER LED
LED
LED
LED
LED
PCB LED
RECEIVER MODULE
S/W PUSH

SPEC
CR501B-Z5U,104Z,50V
SMAW250-08
ABS
DLSO-5031D(RED)
DLG-5031D(GRN)
DLSO-5031D(RED)
DLY-5031D(YLW)
110*31*1.6T.10(288)
TSOP-1838YA1(HOLDER)
JPS2281

Q'TY UNIT
1
1
1
1
1
1
1
1
1
1

REMARK

EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

LED PCB ASS`Y (MODEL : F094/F124/F184/F244)


No

PART CODE

PART NAME

CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV
SW1

CDXE1H104M
3108804800
3103004100
DDLS05031D
DDLG05031D
DDLS05031D
DDLY05031D
3104398202
1TSP1838YA
5S40202000

C-MULTI
WAFER
HOLDER LED
LED
LED
LED
LED
PCB LED
RECEIVER MODULE
S/W PUSH

SPEC
CR501B-Z5U,104Z,50V
SMAW250-08
DLSO-5031D(RED)
DLG-5031D(GRN)
DLSO-5031D(RED)
DLY-5031D(YLW)
150*24.5*1.6T(240)
TSOP-1838YA1(HOLDER)
JPS2281

Q'TY UNIT
1
1
1
1
1
1
1
1
1
1

REMARK

EA
EA
EA
EA
EA
EA
EA
EA
EA
EA

LED PCB ASS`Y (MODEL : F154)


No

PART CODE

CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV

CXCH1H103M
3108804600
3103001100
DDSR302D-DDLG302D-DDSR302D-DDLY302D-3104395412
1TSP1838YA

PART NAME
C CERA
WAFER
LED HOLDER
LED
LED
LED
LED
LED PCB
RECEIVER MODULE

SPEC
103J/50 20%
SMAW250-07
ABS (BLK)
DLSR-302D(RED)
DLG-302D
DLSR-302D(RED)
DLY-302D
67.5*40*1.6T(350)
TSOP-1838YA1(HOLDER)

Q'TY UNIT
1
1
1
1
1
1
1
1
1

REMARK

EA
EA
EA
EA
EA
EA
EA
EA
EA

SWITCH PCB ASS`Y (MODEL : F154)


No

PART CODE

CN1
PCB
SW1

3108804700
3104395311
5S30101330

PART NAME
WAFER
S/W PCB
SWITCH SLIDE

SPEC
SMAW250-02
36*29.5*1.6T(891)
KSA-2340B

86

Q'TY UNIT
1
1
1

EA
EA
EA

REMARK

Power Supply(1)

AC 220V
FUSE1

12V

VAR
D2

D1

275V
104K

CC1

CE1

IC2
7812

CC2

5V

CE2

3.15A

D4

D3

VI VO
+
104

35V
1000F

104

25V
470F

IC3
7805
VI VO

CC3

CL1

CE3
+

104

16V
100F

POWER TRANS

DESCRIPTION
DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving
Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by
Bridge Diode, and it is filtering by Main Condensor CE1.
Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.
And it is regulated +5V DC by Regulator IC7805.
VAR is serge filter and CC1, CC2, CC3 is Noise filter.

Oscillator(2)

5V
19
OSC
20

8M

33

CC13
104

DESCRIPTION
Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.
Ocillatory wave is as following Fig 2-1.

VDD-10%

VSS+10%

Fig 2-1

Sensor(3)
Room temperature and Evaporator temperature Sensor Input

070LH,091LH
182LH, 240LH
330

R8
23

O/C SENSOR

CN10

R9
12.7kF

CC7
103

MICOM
103
CC6

CN9

24

I/C SENSOR

R10
12.7KF

R7 330

ROOM SENSOR

R11
12.7KF

R6 330

25
CC5
103

DESCRIPTION
Number 24, 25 of Micom is Terminal of A/D convertor Input.
Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is put
in 5V by ratio between R10 (12.7K) and R11 (12.7K).
Relation between temperature and voltage is following Table 3-1.
CC5, 6 is Noise filter.
Voltage (V)

Temperature
(C)

No. 1

No. 3

-5

1.127

1.127

1.378

1.378

1.650

1.650

10

1.936

1.936

15

2.228

2.228

Table 3-1

34

Triac Driving(4)
12V
N

L1

TLP561
PT1

AC 220V

130H
3A
MICOM
T1
SM3JZ47

IC4
KID 65004
38

15 R5

SN1
0.1F
120Ohm
TO MOTOR

1K
1/2W

DESCRIPTION
Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied
Trigger Signal.
Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time
delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.

AC220V

TRIGGER
LOWSPEED
SPEED
LOW

MEDIUM SPEED
MEDIUM
SPEED

MOTOR
INPUT

Fig 4-1

35

HIGHSPEED
SPEED
HIGH

Remote Controller(5)
DESCRIPTION
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten
fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.
But in Secondary Wave Custom Code is Reversed Face.

9ms

4.5ms

16bit

24bit

8bit

16bit

0.56ms

LEADER CODE

CUSTOM
CODE

DATA
CODE

CHECK
SUM

1.69ms

1.12ms
bit 0

TAILER

2.25ms
bit 1

Fig 5-2
BIT STRUCTURE

Fig 5-1

Selecting Mode(6)
(SELECT S/W INPUT, OUTPUT)

5V

RA1
R14
1K

MICOM

MODE
SELECT
PUSH S/W

13
P2

CA1
F4104Z

DESCRIPTION
POSITION

There are Mode according to SW position as


following Table 6-1.
According as port of fixed Micom is Low, the unit is
operating as following Table 6-1.

MODE

OPEN

REMOCON

GND

EMERGENCY
Table 6-1

36

0.56ms

Micom Power Supply(7)

5V

VDD 42

CE5
10F
16V

CC11
104

41
MICOM

OSC
8MHz

40
39

19
20
21
VSS

22

CC13
104

DESCRIPTION
MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.

37

Reset(8)

MICOM
R13

5.6K
1K

R12
18

7042P
CC9
10.3

IC5
CE4
4.7uF/50V

DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.

Vcc (+5V)
4.25V

t
DELAY TIME
FOR POWER ON
H

RESET

t
POWER
ON

38

Function Selecting(9)
CA3
F3 104Z
41
40
39

RA3
4A 103J

RA3

R32 1K

JS5

R31 1K

JS4

R30 1K

MICOM

30
JS3

1K R17

JS2

1K R16

F5 104Z
CA1

29
14

RA2

27

16
CA2

R36 heat/low

1K

R28

1K

R25

1K

R24

R33 cool/high

1K

R23

R37 monitoring

1K

R29

28
15

1K R15

JS1

6A 103J
RA1

26

R35 cool/low
R34 heat/high

DESCRIPTION
Selecting function is as following table 9-1.
* When power source is put at fist, Funtion selection input is recognized.
And when the unit is running the microcomputer ignore variation of funtion selection input.
MODEL
DSB-F074LH
DSB-F094LH
DSB-F094PH/AH
DSB-F124LH
DSB-F124PH/AH
MODEL
DSB-F154LH
DSB-F154PH
MODEL
DSB-F184LH
DSB-F184PH/AH
DSB-F244LH
DSB-F244PH/AH

Swing direction
JS1
X
X
X
X
X

Turbo(heating)
JS2
X
X
X
X
X

Flap angle
JS3
X
X
X
X
X

Heating/Cooling Ultra low TEST


JS4
JS5
JS6
O
O
X
O
O
X
O
O
X
O
O
X
O
O
X

Oxygen/Plasma
JS7
O
O
X
O
X

Swing direction
JS1
O
O

Turbo(heating)
JS2
X
X

Flap angle
JS3

Heating/Cooling Ultra low TEST


JS4
JS5
JS6
O
O

O
O

Oxygen/Plasma
J21
O
X

Swing direction
JS1
X
X
X
X

Turbo(heating)
JS2
X
X
X
X

Flap angle
JS3
X
X
X
X

Heating/Cooling Ultra low TEST


JS4
JS5
JS6
O
O

O
O

O
O

O
O

Oxygen/Plasma
J17
O
X
O
X

Buzzer Driving(10)
VCC
12V

DESCRIPTION
MICOM

R4
1K

BZ1

KID 65004
34

11

39

Micom 34 Terminal put out Buzzer Driving Pulse,


its output is driving Buzzer through Buffer.
Ocillatory Frequency of buzzer is selected by
internal Micom.
This unit is setting at 4KHz.

Zero Crossing Detect(11)


VCC

R3
10K
2

TR1
KRC120M
D5

R27
1K

MICOM
31

3
R2
5.6K

D6

TRANS
OUTPUT

CC4
103

DESCRIPTION
It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom.
Detail Driving is as following Fig 11-1.
R19 is Resistance to limit current.

AC18V

The
Number
31 of H
Micom
terminal
L

DETECT POINT
Fig 11-1

40

Stepping Motor Driving(12)

12V
CN13
1
IC6

MICOM

B+

M1
FOR SWING

3
4

KID65004

DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)

(Normal Rotating)

(Reversed Rotating)
Fig 12-1

41

2 KEY COMPONENTS OF ELECTRONIC CIRCUIT


(1) U1 (MICOM)

1 P77(HSO)
Steppping Motor
Driving

VDD 42

2 P76(HSCK) (XTOUT)P22 41
3 P75(SO)

(XTIN)P21 40

4 P74(SI) (INT5/STOP)P20 39
5 P73(SCK)

P17 38

6 P72(PDO/PWM)

P16 37

7 P71(INT4)

Indoor Unit Motor Driving

(TC2)P15 36

8 P70(INT3/TC3) (PPG)P14 35
9 P07

(DVO)P13 34

10 P06

(INT2/TC1)P12 33

11 P05

(INT1)P11 32

12 P04

(INTO)P10 31

Emergency
Mode

13 P03

(AIN7)P67 30

14 P02

(AIN6)P66 29

Function
S/W

15 P01

(AIN5)P65 28

16 P00

(AIN4)P64 27

17 TEST

(AIN3)P63 26

18 RESET

(AIN2)P62 25

19 XIN

(AIN1)P61 24

20 XOUT

(AIN0)P60 23

LED Driving

Reset Curcuit
Oscillation

21 (VASS)VSS

VAREF 22

42

Buzzer Driving
Remocon Input
Comp Relay Driving
Zero Crosing Detect

Function S/W

Temperature
Sensor Input

(2) U2, 4 (KID65004) DARLINGTON ARRAYS


16 OUT 1
15 OUT 2
14 OUT 3
13 OUT 4
12 OUT 5
11 OUT 6
10 OUT 7
9 COMMON FREE
WHEELING DIODES

KID65004AP
COMMON
INPUT

OUTPUT
10.5K
7.2K

3K

IN1 1
IN2 2
IN 3 3
IN 4 4
IN5 5
IN6 6
IN7 7
GND 8

(Equivalent Circuit)

(Top View)

(3) U8 (KIA7805P) : VOLTAGE REGULATOR (5VDC)


SCHEMATIC DIAGRAM
INPUT
100K

100

100

500

10K

240
200

3.3
K

1
2
3

Pin 1. INPUT
2. GROUND
3. OUTPUT

OUTPUT

2K

6K

0.19K

1.4
K

2.7
K

0.3

30pF

28K

5K

500
6K 1K

5K

Fin 2 is ground
for Cose 221A.
Case is ground
for Case 1.

GND

(4) U7 (KIA7812P) : VOLTAGE REGULATOR (12VDC)


10K

INPUT

10K
210
16K
100

300

200

36K
64K

300
50K

520
60K

012

40
pF

50

200

OUTPUT

26K

Pin 1. INPUT
2. GROUND
3. OUTPUT

20K

29K

20K

GND

(Equivalent Ciircuit)

43

GND

(5) U9 (KIA7042P) : RESET IC


1 VCC
KIA70
42P

3 OUT

2 GND

INPUT
GROUND
OUTPUT

OUTLINE

44

3 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD


TEST START

No

Power supply again

Power Supply
Is Display at the
beginning ON?

Select ON/OFF button

Yes
Is Display at the
beginning ON?

No

Select Mode button

Is it normal?

No

ERROR

Select FAN SPEED button

Is it normal?

Select FAN DIR. button

Is it normal?

Is display at the
begining ON?
Select TEMP. Button (,)

Is it normal?

No

ERROR

()
No

ERROR

No

ERROR

(Whenever you selectted Temp.


Button, it is changed by 1C (18~32C)
No

ERROR

Select ON/OFF button

45

No
Check the Following
BATTERY SPRING
MICOM
PCB
LCD

Is LCD display OFF?

No

ERROR

Select TIMER ON Button

Is it normal

No

ERROR

Select Timer Enter Button

TIMER display?

No

ERROR

Select CANCEL Button

Is all display OFF?

No

ERROR

Select ON/OFF Button


Select OFF (Timer) Button

Is it normal?

(0.5~24 HOUR)

No

ERROR

Select SLEEP Button

SLEEP MODE
Display ON?

No

ERROR

Select SLEEP Button

Is display at the
beginning ON?

No

ERROR

TEST OK!
46

9. DISASSEMBLY INSTRUCTIONS
1 INDOOR UNIT
DSB-F074LH
PROCEDURES

PHOTOS

1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
Fig 1
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
1 Draw up the Insert Grille and remove it.
2 Loosen the screw fixed at the Cover Ter-Block.
3 Loosen two screws fixed at the Frame Grille.
4 Remove the Frame Grille.

3. Removing the Control Box. (Fig 3)


1 Remove room and coil thermistors.
2 Disconnect the fan motor lead wire from connection at the
Control PCB.
3 Disconnect the stepping motor lead wire from connection at the
Control PCB.
4 Remove the select switch from connection at the Control PCB.
5 Loosen the screw fixed at the ground wire.
6 Remove the Control Box

4. Removing the Drain Pan. (Fig 4)


1 Disconnect the Body drain hole. (left and right Body)
2 Disconnect three hooks and remove the Drain Pan.

5. Removing the Indoor Evaporator. (Fig 5~6)


1 Remove the screw fixed at the indoor Evaporator of the Body.
2 Remove the hook fixed at the Bracket Pipe of the back of Body.
3 Remove Indoor Evaporator.

6. Removing the Cross Flow Fan. (Fig 7)


1 Remove set screw fixed at the Motor shaft.
2 Remove Cross Flow Fan.

Fig 2

Fig 3

Fig 4

Fig 5

Fig 6

7. Remove Motor IDU and Bearing Plastic.


Fig 7

47

2 OUTDOOR UNIT
DSB-F074LH
PROCEDURES

PHOTOS

1.Stop the operation of the air conditioner and disconnect the wire from
Indoor Unit to Outdoor Unit.

2. Disassemble the case. (Fig 1~2)


1 Remove the Top Panel. (Loosen thirteen screws)
2 Remove the Front Cabinet. (Loosen six screws)
3 Remove the Side Cabinet. (Loosen seven screws)
4 Remove the Guide Support. (Loosen two screws)

3. Removing the Propeller Fan. (Fig 3)


1 Loosen the Nut fixed at the the Propeller Fan.
2 Remove the Plain Washer.
3 Remove the Propeller Fan.

4. Removing the Motor ODU. (Fig 4)


1 Loosen four screws fixed at the Bracket Motor.
2 Disconnect the wire at the Control Panel and remove the Motor ODU.

5. Removing the Dual Capacitor. (Fig 5)


1 Disconnect the wire at the Control Panel.
2 Loosen the screw fixed at the Clamp Capacitor.
3 Remove the Dual Capacitor.

6. Removing the Over load Protector. (Fig 6~7)


1 Loosen the Hex Nut at Terminal Cover.
2 Remove the Terminal Cover.
3 Remove the wire at the Over load Protector.
4 Remove the Over load Protector.

Fig 1

Fig 2

Fig 3

Fig 4

Fig 5

Fig 6

Fig 7

48

3 EXPLODED DIAGRAM (Indoor Unit)


DSB-F074LH

49

DSB-F074LH PART LIST (INDOOR UNIT)


Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
No

PART CODE

PART NAME

Q'TY

3100400301

BODY

HIPS T2.0

3108008700

MOTOR IDU

YDK-8-4B

3101500400

CUSHION MOTOR

CR 30

3106400400

BEARING PLASTIC Ass`y

3100053700

FAN CROSS FLOW Ass`y

90.0 x L540

7485401012

SET SCREW

6S-4x10-E MFZN

3103002601

HOLDER MOTOR

HIPS T2.0

3110050820

EVAPORATOR Ass`y

3102501220

GUIDE EVA.

PVC L536xT0.7

10

3100603800

BRACKET PIPE

HIPS T2.0

11

3108100801

PAN DRAIN

HIPS T2.0

12

3106001600

BLADE VERTICAL

P.P. T1.5

13

3108003900

MOTOR STEPPING

MP24GA , GSP-24SW-061

14

3107600400

FLAP

HIPS T2.5

15

3101404800

COVER WIRE L

HIPS

16

3101404900

COVER WIRE R

HIPS

17

3100054202

LED PCB Ass`y

18

3100901600

CAP RUBBER

19

3110051130

CONTROL BOX Ass`y

19-1

3100508400

CONTROL BOX

19-2

3114302030

CONTROL PCB Ass`y

19-3

3108912310

TERMINAL BLOCK

SN-DBW-05P

19-4

3104896300

SENSOR ID Ass`y

PTM-KD-43C-D2

19-5

3101300100

POWER CORD Ass`y

16A 250V

19-6

3101203000

CLAMP WIRE

P.P. + G.F. 20%

19-7

3102797910

HARNESS

EARTH I/D

19-8

3112704470

HARNESS AC SIGNAL 2

UL1015 WHITE(L6000)

20

3100400410

BODY-TOP

HIPS T2.0

21

3102200800

FRAME GRILLE

HIPS T2.5

22

3104508700

PLATE LED

P.C. Sheet T2.0

23

3104510200

PLATE SWITCH

P.C. Sheet T2.0

24

3101404600

COVER TERMINAL BLOCK

HIPS T2.0

25

3101100400

CASE FILTER

P.P. T2.0

26

3101902510

FILTER CARBON Ass`y

Black

27

3101902610

FILTER ELECTRO Ass`y

White

28

3102200900

FILTER FRAME

P.P. T2.0

29

3112400820

INSERT GRILLE

HIPS T2.5

30

3115500500

COVER LED

ABS() T2.0

31

3104507200

PLATE MOUNTING

SBHG 1 T0.7

50

SPEC

SILICON
P.P. + G.F. 20%

REMARK

4 EXPLODED DIAGRAM (Outdoor Unit)


DSB-F074LH

51

DSB-F074LH PART LIST(OUTDOOR UNIT)


Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
No

PART CODE

PART NAME

3100014730

PAN BASE ASSY

3116005510

BOLT COMP

3102100800

FOOT

SECC T1.2

COMP. GROMMET

EPDM

G4C072JU1ER

M8.4 x 22 xT1.6

4
3117143600
5
6

Q'TY

SPEC

M8 x L45.5

7400208411

COMP. WASHER

7392801211

COMP. NUT

M8 x P1.25 MFZN

311009JB00

CONDENSER ASSY

L465xW208.5xH508

311009JC00

PIPE COND. IN

10

311009JD00

PIPE COND. OUT

11

3100602210

BRACKET SERVICE

SECC T1.2

12

3110051700

SERVICE VALVE

3/8"

13

3110051810

SERVICE VALVE

1/4"

14

7347602011

BOLT HEX

M6 x L20 MFZN

311009JM00
15

DSB-F074LH

PIPE REVERSING ASSY


3115404800

CHECK VALVE

1
1

O.D3.2xI.D1.4xL500

PIPE CAPILLARY COOL

O.D3.2xI.D1.4xL700

3114476600

O.D3.2xI.D1.6xL1000

3114476400

O.D3.2xI.D1.4xL700

O.D3.2xI.D1.4xL700

O.D3.2xI.D1.6xL700

SECC T1.2

3114476300
3114474400
17

3114474500

PIPE CAPILLARY HEAT

3114476700

12.7

18

3102501100

GUIDE SUPPORT

19

3102402600

GRILLE COND.

PE 660x525.5xT3.5

20

3100601903

BRACKET MOTOR

SBHG1 T1.2

YDK-30-6B

ABS+G/F20% (BLACK)

3108008900
21

DSB-F074LH

MOTOR ODU

22

3101801000

FAN PROPELLER

23

7400208411

WASHER PLAIN

PW-2-8 MFZN

24

7392800011

NUT LOCK

M8xP1.25 MFZN

25

3114504110

PLATE PARTITION

SGCC T1.0

26

314201900

PANEL CONTROL

SBHG1 T0.8

27

3108912310

TERMINAL BLOCK

SN-DBW-05P

1.8+30F / 450VAC

3109505720
28

DSB-F074LH

COMPRESSOR ASSY

16

REMARK

CAPACITOR DUAL

52

DSB-F074LH

No

PART CODE

PART NAME

Q'TY

29

3101201100

CLAMP CAPACITOR

SBHG1 T1.0

30

3101202000

CLAMP CORD

NYLON

31

3110801500

CABINET FRONT

SECC T0.8

32

3112402500

GRILLE DISCHARGE

RECTANGULAR

33

3103510700

LABEL BRAND

P.CFILM 346x90xT0.4

34

3100801300

CABINET SIDE

SECC T0.8

35

3104201800

PANEL TOP

SECC T0.8

36

3102600300

HANDLE

A.E.S T2.5 (WH104A)

37

3102101000

FOOT CUSHION

NBR

53

SPEC

REMARK

5 CONTROL BOX ASSEMBLY


DSB-F074LH

54

DSB-F074LH
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).

No
1

PART CODE
3114302030

PART NAME

Q'TY

CONTROL PCB ASS'Y

SPEC

DSB-F074LH

3108003900

MOTOR STEPPING

MP24GA , GSP-24SW-061

3108914300

TERMINAL BLOCK

JXO-CH-05P 600V 30A

3104896300

SENSOR ID ASS'Y

PTM-KD43C-D2

3101300100

POWER CORD ASS'Y

250V 16A H05VV-F 3 x 1.0mm2

3102797610

HARNESS I/D COMP

UL1015 #18 BLU

3102797150

HARNESS 4WAY VALVE

UL1015 #20 BLK

3102704400

HARNESS O/D MOTOR

UL1015 #20 WHT

10

3102797910

HARNESS I/D EARTH

UL1015 #16 GRN/YEL

11

3102704000

HARNESS POWER

UL105 2 x #16 BRN,BLU

12

3102702200

HARNESS TH3

UL2464 2x #24 x 6000

13

3102704500

HARNESS LED PCB

UL1007 8x #24 WHT

14

3101204600

CLAMP CORD

DA-4N

15

3106900300

CAPACITOR IDU

1.0 F 400VAC

55

REMARK