Caution
: In this Manual, some parts can be changed for improving,
their performance without notice in the parts list. So, if you
need the latest parts information,please refer to PPL(Parts
Price List) in Service Information Center (http://svc.dwe.co.kr).
1. SPECIFICATIONS
MODEL
DSB-F074LH
ITEM
Function
Class
T1
Power
AC 220~240V/ 50Hz
Capacity
2,050
Btu/h
7,000
l/h
1.0
Running Current
3.1/3.3
Power Input
680/720
Dehumidification
Electrical
Data
Compressor
Type
Rotary
Model
G4C072JU1ER (Samsung)
Capacitor
30F / 450VAC
Division
Fan
Motor
Indoor Unit
Outdoor Unit
Type
Propeller fan
Capacitor
1.0F 400VAC
1.8F 400VAC
YDK-8-4B
YDK-30-68
dB(A)
39
48
RPM
1,350
850
Refrigerant
(R-410A)
Control
Charge Q'ty
Capillary
g
730
Type
Flare
Connection
OD (Liquid/Gas)
Dimensions (W x H x D)
Net Weight
in(mm)
1/4 (6.35)
3/8 (9.52)
mm
kg
7.0
34
750
Connecting Pipe
Plate Mounting
REMOTE CONTROLLER
REMOCON
Grille Insert
245
Frame Grille
Body
179
Plate Mounting
Indoor Unit
Installation Plate
50
80
460
400
140
40
40
Indoor Unit
17
DSB-F154LH/PH/AH
DSB-182LH
Installation Plate
40
121
385
385
121
Indoor Unit
Installation Plate
40
53
355
285
122
INSTALLING THE
PLATE. DSB-F074LH
INSTALLATION
DSB-070LH/071LH/091LH/092LH
184
Indoor Unit
35
Installation Plate
325
235
12
140
Unit : mm
2 OUTDOOR UNIT
DSB-F074LH
Inlet
Outlet
Foot Cushion
Inlet
Outlet
Cabinet Front
SVC Cover
Servise Valve
3. OPERATION
1 NAME AND FUNCTION OF PARTS
Indoor Unit
DSB-F074LH
Deodorizing Filter
Electrostatic Filter
Removes dust
particles from the air.
Air In
Indoor Cover
02 Hose Cover
(AH Model Only)
Sensor Wire
Connection Cover
Fan Direction
(Up/Down)
Cold Air
Remote
Sensor
Indicators
Indicate the setting
Power Plug
LCD Remote Controller
Outdoor Unit
DSB-F074LH
Connection Cover
AIR IN
Connection Wire
O2 Hose Wire
(AH Models Only)
AIR OUT
Connection Pipes
Drain Hose
Service Valves
The indoor and outdoor units
are connected by copper tubes
which are connected here.
2 REMOTE CONTROLLER
Name of Each Button
DSB-F074LH
Display
Display information
AUTO
ON/OFF Button
Press to turn the unit
on or off.
FAN SPEED Button
Press to select the fan speed
(High " ", Middle " ", Low " ",
Natural).
MODE Button
Press to cycle through the modes
(Auto/Quick/Cool/Fan/Dehumidifier/
Heat)
SLEEP Button
Press to set the unit for the sleep
mode.
MODE
FAN SPEED
FAN DIR.
SLEEP
TEMPERATURE Buttons
Press to raise or lower
the desired temperature.
FAN DIR.
Button
Press to select up/down
direction for fan.
TIMER
ON/OFF
ENTER/
CANCEL
TURBO/MILD
TURBO/MILD
Press to select super power
operation (Turbo) mode.
COVER
Slide down to access most
of the remote buttons.
Slide down further to
access the battery
compartment.
AUTO
FAN Indicators
Light to indicate
the fan speed.
NATURAL Indicator
Light to indicate the
speeds simulating a breeze.
3 DESCRIPTION OF FUNCTIONS
OFF-Timer
If you set time in OFF-Timer Mode, the unit will stop at the set time.
ON
Unit ON
Unit OFF
OFF
SET Time
HOUR
ON-Timer
If you set time in ON-Timer Mode, the unit will run at the set time.
Unit ON
ON
OFF
Unit OFF
SET Time
HOUR
COMP (OFF)
COMP (ON)
COMP (OFF)
-1C
+1C
0C
-1C
(RT-DT)
+1C
0C
(RT-DT)
HEATING
(COOLING)
(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of room
temperature.
Buzzer
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,
beep".
(1) In the case of receiving ON/OFF signal-"beep" "beep"
(2) And so on-"beep"
9
DEHUMI-
COOL
AUTO
QUICK
HEAT
DIFICATION
H
Auto
Auto
Auto
Auto
Natural
Natural
Natural
Natural
Natural
(COOLING)
H
M
L
0C
1C
2C
(R.T-D.T)
(HEATING)
H
M
L
0C
1C
10
2C
(DT-RT)
MODE
Turbo
High
Mid
Low
Ultra low
Monitoring
COOL
1360
1350
1290
1060
910
HEAT
1230
1120
1060
820
500
COOL
1280
1250
1150
990
840
HEAT
1120
1020
970
800
500
COOL
1290
1260
1150
970
840
HEAT
1300
1220
1070
910
500
COOL
1390
1380
1320
1020
940
HEAT
1350
1260
1090
910
500
COOL
1280
1260
1170
1020
900
HEAT
1150
1050
1000
870
500
COOL
1280
1260
1170
1020
900
HEAT
1260
1170
1020
900
500
Sleep Mode
(1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature.
(The unit will not operate after 4 hour)
(2) For changing the temperature.
DT
DT
+0.5C
+0.5C
0.5C
+0.5C
0.5C
0.5C
0.5
1.0
HOUR
(COOLING CYCLE)
0.5
1.0
HOUR
(HEATING CYCLE)
(3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP
indicator will disappear in the display.
Emergency Operation
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can be
used to run the unit.
(2) The setting conditions of Emergency operation are as follows.
Operation mode: Quick
Preset temperature:18C: Cooling, 32C: Heating)
Fan speed: High
* You cannot operate with remote controller.
11
Compressor and
Outdoor Fan
ON
ON
OFF
Set speed
Indoor Fan
-1C
+7C
Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selecting
operating Mode according to the room temperature
(RT: Room temperature)
ROOM TEMPERATURE
OPERATING MODE
FLAP POSITION
> RT
DT-2C RT DT+3C
DT+3C < RT
Heating
Heating Position
Dehumidifier
Cooling Position
Cooling
Cooling Position
DT-2C
12
Dehumidification Mode
1 Desired temperature < Room temperature
Up/Down
Fixed
Up/Down
COOLING POSITION
HEATING POSITION
1) Heating Mode
* When the room temperature is higher than 22C
1 Fan Speed: Super high speed
2 Air discharge direction: Fixed
3 Set temperature: 18C (Fixed)
4 Compressor and Outdoor Fan
The air discharge direction procedure is below
Up/Down
Fixed
Fixed
Up/Down
Up/Down
Fixed
13
Return
Comp
4 Way
OD Fan
ID Fan
40sec
*Note1
6sec
15min
*Note2
40sec
6sec
60C
57C
49C
38C
ID FAN
* Note1
Monitoring
"Ultra Low"
Set Value
"Hi, Mid, Low"
OD FAN
"Hi"
"Hi"
OFF *Note2
COMP
OFF *Note3
Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
(1)Error Code Display Pattern
1 ON LAMP: Blink
LED BLINK PATTERN
CASE
NOTE
0.5s
8s
Do not woorking
2 times blink
Continuously workiug
Gas leak
15
4. WIRING DIAGRAM
Indoor Unit
Indoor Unit
DSB-F094, 124LH
DSB-F094, 124PH
40
Outdoor Unit
DSB-F094, 124AH
DSB-F154, 184AH
DSB-F244LH/PH
43
5. REFRIGERANT CYCLE
[Heat Pump Mode]
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.
18
MODEL
DSB-F074
REFRIGERANT
730g
INDOOR ROOM
OUTDOOR ROOM
TEMP.(DB/WB, C) TEMP.(DB/WB, C)
27.0/19.0
LH/AH
DSB-F094
900g
27.0/19.0
LH/PH/AH
DSB-F124
1,000g
27.0/19.0
LH/PH/AH
DSB-F154
1,150g
27.0/19.0
LH/PH/AH
DSB-F184
1,200g
27.0/19.0
LH/PH/AH
DSB-F244
1,750g
27.0/19.0
LH/PH/AH
SUCTION PRESSURE
Bar (gage)
kPa, (gage)
25.0 /
8.3
830
30.0 /
8.7
870
35.0 /
9.1
912
40.0 /
9.2
925
45.0 /
9.7
970
25.0 /
8.5
850
30.0 /
8.9
890
35.0 /
9.3
932
40.0 /
9.4
945
45.0 /
9.9
990
25.0 /
7.6
760
30.0 /
8.0
800
35.0 /
8.4
843
40.0 /
8.6
860
45.0 /
9.0
900
25.0 /
8.0
800
30.0 /
8.4
840
35.0 /
8.8
883
40.0 /
9.0
900
45.0 /
9.4
940
25.0 /
7.6
760
30.0 /
8.0
800
35.0 /
8.4
840
40.0 /
8.6
860
45.0 /
9.0
900
25.0 /
7.6
760
30.0 /
8.0
800
35.0 /
8.4
840
40.0 /
8.6
860
45.0 /
9.0
900
NOTE)
1) These experiments are processed on the condition of the fixed indoor room TEMP.( DB: 27.0C, WB: 19.0C)
2) It takes at least ten minutes for the change of suction pressure to be steady-state, after Air conditioner operates
3) To analyze accurately whether refrigerant of Air conditioner leaks or not, you have to check not only suction
pressure but also discharge and suction temperature of compressor
4) These data can be changed slightly according to the temperature of environment or each set(Air conditioner)
19
PRESSURE(LIQUID): bar
7.991
8.248
8.511
8.781
9.057
9.339
9.628
9.924
10.23
10.54
10.85
11.18
11.51
11.85
12.19
12.54
12.9
13.27
13.65
14.03
14.43
14.83
15.24
15.65
16.08
16.52
16.96
17.41
17.87
18.34
18.83
19.31
19.81
20.32
20.84
21.37
21.91
22.46
23.02
23.59
24.17
24.76
25.37
25.98
26.61
27.24
27.89
28.55
29.23
29.91
30.61
31.32
32.04
32.78
33.53
34.29
35.07
35.86
36.67
37.49
38.33
PRESSURE(VAPOR): bar
7.967
8.223
8.486
8.754
9.029
9.311
9.599
9.894
10.2
10.5
10.82
11.14
11.47
11.81
12.15
12.51
12.87
13.23
13.61
13.99
14.38
14.78
15.19
15.61
16.03
16.47
16.91
17.36
17.82
18.29
18.77
19.26
19.76
20.26
20.78
21.31
21.85
22.4
22.95
23.52
24.1
24.69
25.3
25.91
26.53
27.17
27.82
28.48
29.15
29.84
30.53
31.24
31.97
32.7
33.45
34.22
35
35.79
36.59
37.42
38.25
20
R22
PRESSURE: bar
4.98
5.144
5.312
5.484
5.661
5.841
6.026
6.215
6.409
6.607
6.809
7.017
7.229
7.445
7.667
7.893
8.124
8.361
8.602
8.848
9.1
9.357
9.619
9.887
10.16
10.44
10.72
11.01
11.31
11.61
11.92
12.23
12.55
12.88
13.21
13.55
13.89
14.24
14.6
14.97
15.34
15.71
16.1
16.49
16.89
17.29
17.7
18.12
18.55
18.99
19.43
19.88
20.33
20.8
21.27
21.75
22.24
22.74
23.24
23.75
24.27
Unit on lamp
Remote
Emergency
Operating Mode
Signal
receiver
Fan Speed
Timer Selection
Quick lamp
Flap Position
Operation
Timer lamp
Temp. Setting
ON/OFF
Room air temp.
SLEEP
REMOCON
* Outdoor coil
temp
Stepping
motor
lnitialization
MICRO
CONTROLLER
Clock generation
DC5V
DC power supply
circuit for
motor driving
SMPS
AC220V
50Hz
DC12V
STEPPING MOTOR
ON/OFF
COMPRESSOR
ON/OFF
Circuit for
relay driving
Circuit for
TRIAC control
Relay RL3
Relay RL2
Relay RL1
TRIAC
* 4 way
valve
* Outdoor
fan motor
Compressor
Indoor fan
motor
21
7. TROUBLE SHOOTING
Is the unit
display
mormal?
YES
NO
NO
Is the
unit display
normal?
YES
Does
the compressor run
normally?
YES
Indoor unit does
not run(note 1)
YES
Check the failure
code according to
the self diagnostic
(note 2)
NO
NO
Normal
check the
connecting
point of
magnetic
contactor
NO
Trouble
Is the power
applied to the
unit
YES
Is the
power normal?
check the voltage between
L & N of terminal
block
YES
Does the
beeper beep two
times?
YES
Is the display
all off?
YES
NO
NO
NO
NO
Is the
switch position
on switch pannel at
"Remote"
YES
YES
Does
control PCB
status LED repeat one
second "on and
off"?
control PCB fault
Micom or reset
IC fault
NO
22
Note 1)
1 Neither indoor unit nor outdoor unit runs.
Check the following points first. (There are following case in normal operation)
a. Is the timer mode set the "timer ON".
b. Is the timer mode set the "timer-OFF" and the time had passed?
2 Neither outdoor fan nor compressor runs while indoor fan runs.
Check following points first. (There are following cases in normal operation)
a. Is the temperature set point suitable?
b. Has the 3 minutes time guard for compressor operated?
Self-Diagnostic Function
Error Code
1 When the compressor do not run.
i) Check the voltage between L and Y of terminal block.
(Indoor Unit, Outdoor Unit)
ii) Check connecting wire of indoor unit and outdoor unit.
iii) Check relay RL1 on power P.C.B
2 Check fixing of indoor coil thermistor.
3 Check the GAS LEAKAGE of the pipe.
23
Rating voltage
Check the voltge between L and
Y of terminal block
under 90%
Check the
Breaker or Fuse
Yes
Press the ON/OFF switch of
Remote Control
No
Self Diagnostic
function is ON
Yes
No
Check according to
self Diagnostic function
24
NO
Rating voltage
under 90%
Normal
Check the fan motor capacitor
Run again
No
Run again
25
Normal
Rating voltage
under 90%
Rating voltage
Check the voltge between L and
Y of outdoor unit terminal
under 90%
Check compressor,
outdoor fan motor individually
26
Check the
connecting wire
NG
Open or Short
Change the
compressor.
OK
Check the compressor capacitor
RL4
Turn ON
O2 Generator
Motor
High Volt
Generator
27
28
SPEC
QTY
LOCATION
USE
FUSE
FUSE CLIP
AFC-520
FUSE
VARISTOR
15G561K
VAR
WAFER
YW396-05AVD
CN2
WAFER
YW396-03AVD
CN1
C-CERA
104Z,50VDC
CC1,2,5,6,7
C-CERA
103Z,50VDC
CC3,4,9,10,11,12
C-MULTI
104Z,CR0561B-Z5U
CC8
C-ELEC
470uF 35V SD
CE1
C-ELEC
10uF 450V SD
CE3,CE4
C-ELEC
100uF 16V SD
CE2
C-ELEC
10uF 16V SS
CE5
C-ELEC
4.7uF 50V SS
CE6
C-ARRAY
F3 104Z
CA3
C-ARRAY
F4 104Z
CA2
C-ARRAY
F5 104Z
CA1
RESISTOR
1/4W-12.7KF
R27,28,29
RESISTOR
1/4W-1KJ
21
R5,12,13,14,15,16,17,18,19,20,
R21,23,30,31,32,33,34,35,36,37,43
RESISTOR
1/4W-10KJ
R11
RESISTOR
1/4W-5.6KJ
R22
RESISTOR
1/4W-330J
R24,25,26
RESISTOR
1/4W-100J
R1,R4
RESISTOR
1/4W-68KJ
R8,R9
RESISTOR
1/4W-51KJ
R6
RESISTOR
1/4W-2KJ
R7
RESISTOR
1/2W-1KJ
R2
RESISTOR
1W-47J
R3
RESISTOR
1/4W-3.24KF
R41
RESISTOR
1/4W-49.9KF
R40
RESISTOR
1/4W-32.4KF
R38
RESISTOR
1/4W-24.9KF
R39,42
RESISTOR ARRAY
4A 103J
RA3
RESISTOR ARRAY
5A 103J
RA2
RESISTOR ARRAY
6A 103J
RA1
PIN
GP881205-2(187)
CN4
C-LINE ACROSS
275V 104K
CL1,CL2
WAFER
YFW800-01D
CN3
WAFER
SMAW250-06(WHITE)
CN6
WAFER
SMAW250-08
CN5
WAFER
YMAW250-04
CN7
WAFER
YMAW250-02
CN8
DIODE
1N4007 TAPE
D3
29
PART NAME
SPEC
QTY
LOCATION
DIODE
UF203
D2
DIODE ZENOR
1N5241B
ZD1
DIODE
ST01D-200
D1
C-CERA
2200pF, 250V
CY1
CHOKE COIL
1mH, 0.5A
L1
FILTER EMI
0.6*10*3TURN
L2
BUZZER
BM-20K
BZ1
COIL
130uH, 3A
L3
IC REGULATOR
KIA7805P
IC3
TR
KRC102M
TR1
IC RESET
KIA7042P
IC5
RELAY
US11-12S
RL3
RELAY
UKH-12S
RL1
SW TRANS
264P,1916
TRS1
CAPACITOR
1uF,400VAC
CAP1
PCB CONTROL
162.5X140X1.6T
PCB
IC SWITCHING
TNY264P
IC2
DIODE BRIDGE
S1NB80
BD1
TRIAC
SM3JZ47
T1
PHOTO COUPLER
TLP560J
PT1
IC DRIVE
TD62004AP
IC4,IC6
RESONATOR
CST8.00MGW
OSC
IC MICOM
TMP87C846AN
IC1
PHOTO COUPLER
TLP421
PC1,PC2
30
COOL LOW
HEAT HIGH
HEAT LOW
MONITORING
R41
R39
R40
R38
R42
3.24
24.9
49.9
32.4
24.9
COOL HIGH
COOL LOW
HEAT HIGH
HEAT LOW
MONITORING
R28
R30
R29
R31
R27
3.65
22.6
32.4
36.5
22.1
COOL HIGH
COOL LOW
HEAT HIGH
HEAT LOW
MONITORING
R33
R35
R34
R36
R37
DSB-F184LH/PH/AH
5.76
12.4
32.4
22.1
22.1
DSB-F244LH/PH/AH
5.76
12.4
5.76
12.4
22.1
MODEL
DSB-F074LH
MODEL
DSB-F154LH/PH
MODEL
85
PART CODE
PART NAME
CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV
SW1
CDXE1H104M
3108804800
3103002700
DDLS05031D
DDLG05031D
DDLS05031D
DDLY05031D
3104398201
1TSP1838YA
5S40202000
C-MULTI
WAFER
HOLDER LED
LED
LED
LED
LED
PCB LED
RECEIVER MODULE
S/W PUSH
SPEC
CR501B-Z5U,104Z,50V
SMAW250-08
ABS
DLSO-5031D(RED)
DLG-5031D(GRN)
DLSO-5031D(RED)
DLY-5031D(YLW)
110*31*1.6T.10(288)
TSOP-1838YA1(HOLDER)
JPS2281
Q'TY UNIT
1
1
1
1
1
1
1
1
1
1
REMARK
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
PART CODE
PART NAME
CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV
SW1
CDXE1H104M
3108804800
3103004100
DDLS05031D
DDLG05031D
DDLS05031D
DDLY05031D
3104398202
1TSP1838YA
5S40202000
C-MULTI
WAFER
HOLDER LED
LED
LED
LED
LED
PCB LED
RECEIVER MODULE
S/W PUSH
SPEC
CR501B-Z5U,104Z,50V
SMAW250-08
DLSO-5031D(RED)
DLG-5031D(GRN)
DLSO-5031D(RED)
DLY-5031D(YLW)
150*24.5*1.6T(240)
TSOP-1838YA1(HOLDER)
JPS2281
Q'TY UNIT
1
1
1
1
1
1
1
1
1
1
REMARK
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
PART CODE
CC1
CN1
HOLD
L1
L2
L3
L4
PCB
RCV
CXCH1H103M
3108804600
3103001100
DDSR302D-DDLG302D-DDSR302D-DDLY302D-3104395412
1TSP1838YA
PART NAME
C CERA
WAFER
LED HOLDER
LED
LED
LED
LED
LED PCB
RECEIVER MODULE
SPEC
103J/50 20%
SMAW250-07
ABS (BLK)
DLSR-302D(RED)
DLG-302D
DLSR-302D(RED)
DLY-302D
67.5*40*1.6T(350)
TSOP-1838YA1(HOLDER)
Q'TY UNIT
1
1
1
1
1
1
1
1
1
REMARK
EA
EA
EA
EA
EA
EA
EA
EA
EA
PART CODE
CN1
PCB
SW1
3108804700
3104395311
5S30101330
PART NAME
WAFER
S/W PCB
SWITCH SLIDE
SPEC
SMAW250-02
36*29.5*1.6T(891)
KSA-2340B
86
Q'TY UNIT
1
1
1
EA
EA
EA
REMARK
Power Supply(1)
AC 220V
FUSE1
12V
VAR
D2
D1
275V
104K
CC1
CE1
IC2
7812
CC2
5V
CE2
3.15A
D4
D3
VI VO
+
104
35V
1000F
104
25V
470F
IC3
7805
VI VO
CC3
CL1
CE3
+
104
16V
100F
POWER TRANS
DESCRIPTION
DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving
Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by
Bridge Diode, and it is filtering by Main Condensor CE1.
Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.
And it is regulated +5V DC by Regulator IC7805.
VAR is serge filter and CC1, CC2, CC3 is Noise filter.
Oscillator(2)
5V
19
OSC
20
8M
33
CC13
104
DESCRIPTION
Oscillatory Frequency drive Micom, it is made up 8MHz resonator oscillatory Freqency.
Ocillatory wave is as following Fig 2-1.
VDD-10%
VSS+10%
Fig 2-1
Sensor(3)
Room temperature and Evaporator temperature Sensor Input
070LH,091LH
182LH, 240LH
330
R8
23
O/C SENSOR
CN10
R9
12.7kF
CC7
103
MICOM
103
CC6
CN9
24
I/C SENSOR
R10
12.7KF
R7 330
ROOM SENSOR
R11
12.7KF
R6 330
25
CC5
103
DESCRIPTION
Number 24, 25 of Micom is Terminal of A/D convertor Input.
Room temperature and Evaporator temperature is sensing by change of Thermister Resistance, Micom is put
in 5V by ratio between R10 (12.7K) and R11 (12.7K).
Relation between temperature and voltage is following Table 3-1.
CC5, 6 is Noise filter.
Voltage (V)
Temperature
(C)
No. 1
No. 3
-5
1.127
1.127
1.378
1.378
1.650
1.650
10
1.936
1.936
15
2.228
2.228
Table 3-1
34
Triac Driving(4)
12V
N
L1
TLP561
PT1
AC 220V
130H
3A
MICOM
T1
SM3JZ47
IC4
KID 65004
38
15 R5
SN1
0.1F
120Ohm
TO MOTOR
1K
1/2W
DESCRIPTION
Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied
Trigger Signal.
Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time
delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.
AC220V
TRIGGER
LOWSPEED
SPEED
LOW
MEDIUM SPEED
MEDIUM
SPEED
MOTOR
INPUT
Fig 4-1
35
HIGHSPEED
SPEED
HIGH
Remote Controller(5)
DESCRIPTION
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten
fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.
But in Secondary Wave Custom Code is Reversed Face.
9ms
4.5ms
16bit
24bit
8bit
16bit
0.56ms
LEADER CODE
CUSTOM
CODE
DATA
CODE
CHECK
SUM
1.69ms
1.12ms
bit 0
TAILER
2.25ms
bit 1
Fig 5-2
BIT STRUCTURE
Fig 5-1
Selecting Mode(6)
(SELECT S/W INPUT, OUTPUT)
5V
RA1
R14
1K
MICOM
MODE
SELECT
PUSH S/W
13
P2
CA1
F4104Z
DESCRIPTION
POSITION
MODE
OPEN
REMOCON
GND
EMERGENCY
Table 6-1
36
0.56ms
5V
VDD 42
CE5
10F
16V
CC11
104
41
MICOM
OSC
8MHz
40
39
19
20
21
VSS
22
CC13
104
DESCRIPTION
MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
37
Reset(8)
MICOM
R13
5.6K
1K
R12
18
7042P
CC9
10.3
IC5
CE4
4.7uF/50V
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.
Vcc (+5V)
4.25V
t
DELAY TIME
FOR POWER ON
H
RESET
t
POWER
ON
38
Function Selecting(9)
CA3
F3 104Z
41
40
39
RA3
4A 103J
RA3
R32 1K
JS5
R31 1K
JS4
R30 1K
MICOM
30
JS3
1K R17
JS2
1K R16
F5 104Z
CA1
29
14
RA2
27
16
CA2
R36 heat/low
1K
R28
1K
R25
1K
R24
R33 cool/high
1K
R23
R37 monitoring
1K
R29
28
15
1K R15
JS1
6A 103J
RA1
26
R35 cool/low
R34 heat/high
DESCRIPTION
Selecting function is as following table 9-1.
* When power source is put at fist, Funtion selection input is recognized.
And when the unit is running the microcomputer ignore variation of funtion selection input.
MODEL
DSB-F074LH
DSB-F094LH
DSB-F094PH/AH
DSB-F124LH
DSB-F124PH/AH
MODEL
DSB-F154LH
DSB-F154PH
MODEL
DSB-F184LH
DSB-F184PH/AH
DSB-F244LH
DSB-F244PH/AH
Swing direction
JS1
X
X
X
X
X
Turbo(heating)
JS2
X
X
X
X
X
Flap angle
JS3
X
X
X
X
X
Oxygen/Plasma
JS7
O
O
X
O
X
Swing direction
JS1
O
O
Turbo(heating)
JS2
X
X
Flap angle
JS3
O
O
Oxygen/Plasma
J21
O
X
Swing direction
JS1
X
X
X
X
Turbo(heating)
JS2
X
X
X
X
Flap angle
JS3
X
X
X
X
O
O
O
O
O
O
Oxygen/Plasma
J17
O
X
O
X
Buzzer Driving(10)
VCC
12V
DESCRIPTION
MICOM
R4
1K
BZ1
KID 65004
34
11
39
R3
10K
2
TR1
KRC120M
D5
R27
1K
MICOM
31
3
R2
5.6K
D6
TRANS
OUTPUT
CC4
103
DESCRIPTION
It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom.
Detail Driving is as following Fig 11-1.
R19 is Resistance to limit current.
AC18V
The
Number
31 of H
Micom
terminal
L
DETECT POINT
Fig 11-1
40
12V
CN13
1
IC6
MICOM
B+
M1
FOR SWING
3
4
KID65004
DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)
(Normal Rotating)
(Reversed Rotating)
Fig 12-1
41
1 P77(HSO)
Steppping Motor
Driving
VDD 42
2 P76(HSCK) (XTOUT)P22 41
3 P75(SO)
(XTIN)P21 40
4 P74(SI) (INT5/STOP)P20 39
5 P73(SCK)
P17 38
6 P72(PDO/PWM)
P16 37
7 P71(INT4)
(TC2)P15 36
8 P70(INT3/TC3) (PPG)P14 35
9 P07
(DVO)P13 34
10 P06
(INT2/TC1)P12 33
11 P05
(INT1)P11 32
12 P04
(INTO)P10 31
Emergency
Mode
13 P03
(AIN7)P67 30
14 P02
(AIN6)P66 29
Function
S/W
15 P01
(AIN5)P65 28
16 P00
(AIN4)P64 27
17 TEST
(AIN3)P63 26
18 RESET
(AIN2)P62 25
19 XIN
(AIN1)P61 24
20 XOUT
(AIN0)P60 23
LED Driving
Reset Curcuit
Oscillation
21 (VASS)VSS
VAREF 22
42
Buzzer Driving
Remocon Input
Comp Relay Driving
Zero Crosing Detect
Function S/W
Temperature
Sensor Input
KID65004AP
COMMON
INPUT
OUTPUT
10.5K
7.2K
3K
IN1 1
IN2 2
IN 3 3
IN 4 4
IN5 5
IN6 6
IN7 7
GND 8
(Equivalent Circuit)
(Top View)
100
100
500
10K
240
200
3.3
K
1
2
3
Pin 1. INPUT
2. GROUND
3. OUTPUT
OUTPUT
2K
6K
0.19K
1.4
K
2.7
K
0.3
30pF
28K
5K
500
6K 1K
5K
Fin 2 is ground
for Cose 221A.
Case is ground
for Case 1.
GND
INPUT
10K
210
16K
100
300
200
36K
64K
300
50K
520
60K
012
40
pF
50
200
OUTPUT
26K
Pin 1. INPUT
2. GROUND
3. OUTPUT
20K
29K
20K
GND
(Equivalent Ciircuit)
43
GND
3 OUT
2 GND
INPUT
GROUND
OUTPUT
OUTLINE
44
No
Power Supply
Is Display at the
beginning ON?
Yes
Is Display at the
beginning ON?
No
Is it normal?
No
ERROR
Is it normal?
Is it normal?
Is display at the
begining ON?
Select TEMP. Button (,)
Is it normal?
No
ERROR
()
No
ERROR
No
ERROR
ERROR
45
No
Check the Following
BATTERY SPRING
MICOM
PCB
LCD
No
ERROR
Is it normal
No
ERROR
TIMER display?
No
ERROR
No
ERROR
Is it normal?
(0.5~24 HOUR)
No
ERROR
SLEEP MODE
Display ON?
No
ERROR
Is display at the
beginning ON?
No
ERROR
TEST OK!
46
9. DISASSEMBLY INSTRUCTIONS
1 INDOOR UNIT
DSB-F074LH
PROCEDURES
PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
Fig 1
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
1 Draw up the Insert Grille and remove it.
2 Loosen the screw fixed at the Cover Ter-Block.
3 Loosen two screws fixed at the Frame Grille.
4 Remove the Frame Grille.
Fig 2
Fig 3
Fig 4
Fig 5
Fig 6
47
2 OUTDOOR UNIT
DSB-F074LH
PROCEDURES
PHOTOS
1.Stop the operation of the air conditioner and disconnect the wire from
Indoor Unit to Outdoor Unit.
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Fig 6
Fig 7
48
49
PART CODE
PART NAME
Q'TY
3100400301
BODY
HIPS T2.0
3108008700
MOTOR IDU
YDK-8-4B
3101500400
CUSHION MOTOR
CR 30
3106400400
3100053700
90.0 x L540
7485401012
SET SCREW
6S-4x10-E MFZN
3103002601
HOLDER MOTOR
HIPS T2.0
3110050820
EVAPORATOR Ass`y
3102501220
GUIDE EVA.
PVC L536xT0.7
10
3100603800
BRACKET PIPE
HIPS T2.0
11
3108100801
PAN DRAIN
HIPS T2.0
12
3106001600
BLADE VERTICAL
P.P. T1.5
13
3108003900
MOTOR STEPPING
MP24GA , GSP-24SW-061
14
3107600400
FLAP
HIPS T2.5
15
3101404800
COVER WIRE L
HIPS
16
3101404900
COVER WIRE R
HIPS
17
3100054202
18
3100901600
CAP RUBBER
19
3110051130
19-1
3100508400
CONTROL BOX
19-2
3114302030
19-3
3108912310
TERMINAL BLOCK
SN-DBW-05P
19-4
3104896300
SENSOR ID Ass`y
PTM-KD-43C-D2
19-5
3101300100
16A 250V
19-6
3101203000
CLAMP WIRE
19-7
3102797910
HARNESS
EARTH I/D
19-8
3112704470
HARNESS AC SIGNAL 2
UL1015 WHITE(L6000)
20
3100400410
BODY-TOP
HIPS T2.0
21
3102200800
FRAME GRILLE
HIPS T2.5
22
3104508700
PLATE LED
23
3104510200
PLATE SWITCH
24
3101404600
HIPS T2.0
25
3101100400
CASE FILTER
P.P. T2.0
26
3101902510
Black
27
3101902610
White
28
3102200900
FILTER FRAME
P.P. T2.0
29
3112400820
INSERT GRILLE
HIPS T2.5
30
3115500500
COVER LED
ABS() T2.0
31
3104507200
PLATE MOUNTING
SBHG 1 T0.7
50
SPEC
SILICON
P.P. + G.F. 20%
REMARK
51
PART CODE
PART NAME
3100014730
3116005510
BOLT COMP
3102100800
FOOT
SECC T1.2
COMP. GROMMET
EPDM
G4C072JU1ER
M8.4 x 22 xT1.6
4
3117143600
5
6
Q'TY
SPEC
M8 x L45.5
7400208411
COMP. WASHER
7392801211
COMP. NUT
M8 x P1.25 MFZN
311009JB00
CONDENSER ASSY
L465xW208.5xH508
311009JC00
PIPE COND. IN
10
311009JD00
11
3100602210
BRACKET SERVICE
SECC T1.2
12
3110051700
SERVICE VALVE
3/8"
13
3110051810
SERVICE VALVE
1/4"
14
7347602011
BOLT HEX
M6 x L20 MFZN
311009JM00
15
DSB-F074LH
CHECK VALVE
1
1
O.D3.2xI.D1.4xL500
O.D3.2xI.D1.4xL700
3114476600
O.D3.2xI.D1.6xL1000
3114476400
O.D3.2xI.D1.4xL700
O.D3.2xI.D1.4xL700
O.D3.2xI.D1.6xL700
SECC T1.2
3114476300
3114474400
17
3114474500
3114476700
12.7
18
3102501100
GUIDE SUPPORT
19
3102402600
GRILLE COND.
PE 660x525.5xT3.5
20
3100601903
BRACKET MOTOR
SBHG1 T1.2
YDK-30-6B
ABS+G/F20% (BLACK)
3108008900
21
DSB-F074LH
MOTOR ODU
22
3101801000
FAN PROPELLER
23
7400208411
WASHER PLAIN
PW-2-8 MFZN
24
7392800011
NUT LOCK
M8xP1.25 MFZN
25
3114504110
PLATE PARTITION
SGCC T1.0
26
314201900
PANEL CONTROL
SBHG1 T0.8
27
3108912310
TERMINAL BLOCK
SN-DBW-05P
1.8+30F / 450VAC
3109505720
28
DSB-F074LH
COMPRESSOR ASSY
16
REMARK
CAPACITOR DUAL
52
DSB-F074LH
No
PART CODE
PART NAME
Q'TY
29
3101201100
CLAMP CAPACITOR
SBHG1 T1.0
30
3101202000
CLAMP CORD
NYLON
31
3110801500
CABINET FRONT
SECC T0.8
32
3112402500
GRILLE DISCHARGE
RECTANGULAR
33
3103510700
LABEL BRAND
P.CFILM 346x90xT0.4
34
3100801300
CABINET SIDE
SECC T0.8
35
3104201800
PANEL TOP
SECC T0.8
36
3102600300
HANDLE
37
3102101000
FOOT CUSHION
NBR
53
SPEC
REMARK
54
DSB-F074LH
Caution : In this Manual, some parts can be changed for improving, their performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in Service Information Center (http://svc.dwe.co.kr).
No
1
PART CODE
3114302030
PART NAME
Q'TY
SPEC
DSB-F074LH
3108003900
MOTOR STEPPING
MP24GA , GSP-24SW-061
3108914300
TERMINAL BLOCK
3104896300
SENSOR ID ASS'Y
PTM-KD43C-D2
3101300100
3102797610
3102797150
3102704400
10
3102797910
11
3102704000
HARNESS POWER
12
3102702200
HARNESS TH3
13
3102704500
14
3101204600
CLAMP CORD
DA-4N
15
3106900300
CAPACITOR IDU
1.0 F 400VAC
55
REMARK