Anda di halaman 1dari 7

COMPREHENSIVE RESUME

HASTO PUTRO

Senior Electrical & Instrument Inspector


Presented: January 2012

PERSONAL DETAILS:
Name
Date of Birth
Nationality
Status
Religion
Languages
Computer Literacy
Telephone Number/Office

Fax Number Office


Office Email

: Hasto Putro
: January 27, 1967
: Indonesia
: Married
: Muslim
: Bahasa Indonesia, English.
: MS Office, AutoCAD, SAP, VB, etc
: +6221 70913650
: +6221 7364130
+6221 7364033
+6221 73883323
: hasto.putro@dbesglobal08.co.id

Electrical & Instrument Inspector

EDUCATION:
Oct 1986 Oct 1989, Graduated/ D3 degree from Polytechnic University of Diponegoro
Semarang, Majoring in Electrical Engineering. GPA 3.40
Oct 2001 Dec 2004, Graduated/ S1 degree from University Of Indonesia Jakarta, Majoring
in Management GPA 3.20
Inspection Experiences
As Inspector for Low Voltage Switch Gear
o Low & MediumVoltage Electrical Switchgear:
Mechanical assembly Frame and component
Bus bar connection and main power
Insulation resistance test
Dielectric withstand test
Grounding masses continuity test
Electrical check
Sequence test
Motor mechanism test (contactor, relay, switching, circuit breaker)
Electrical Locking
Metering circuit
Checking the test function
Protective circuit
Main circuit
Interlock system
Interconnection system
o References International Standard
IEC - International Electrotechnical Commission
ISO - International Standard for Organization
VDE German Industrial Electrical Standard
CENELEC European Committee for Electrotehnical Standardization
Relevant HD & EN European Union (EU) Standard & Specifications
Standard References for Low Voltage Switch Gear
IEC 60439 - low voltage switchgear and controlgear assemblies
switchboard general standard
IEC/TR61647 Enclosed low voltage switchgear and controlgear
assemblies Guide for testing under condition of arcing due to an
internal fault
IEC 60529 Degrees of protection provided by enclosure

IEC 60068-2-6 - Environmental testing Vibration


IEC 60947-1 - Low voltage switchgear and controlgear - general
rule
IEC 60947-2 - Low voltage switchgear and controlgear circuit
breaker
IEC 60947-3 - Low voltage switchgear and controlgear switches,
disconnectors, switch-disconnectors and fuse combination unit.
IEC 60947-4 - Low voltage switchgear and controlgear contactor
and motor stater.
IEC 60038 Standard Voltage
ISO 9000 Series Quality System Standard
Amendments Amendments to any of the above by local
regulatory body.

As Inspector for Distribution and Power Transformer


o Fabrication & Process Inspection
Core and assembly and winding connection
Turn ratio and vector group test
Transformer assembly
Final leakage test
Tank Painting
Testing
Finishing
o Routine Test
Transformation Ratio
Winding Resistance
Load/copper test
No load/core lost-LV Side
No load/core lost-HV Side
Harmonic measurement
Measurement of winding insulation resistance/Megger test
Measurement of Polarisation index
Dielectric test of core to earth
Measurement of capacitance and tan of the windings
Measurement of capacitance and tan of the bushings
Verification current transformer ratio and polarity
Impedance voltage
Measurement of zero sequence impedance(s) 3 phase transformer
Separate sources voltage withstand test
Test on On-Load tap changer
Functional test of control equipment and accessories
Breakdown voltage of the insulating oil
Dissipation factor of the insulating oil
Dielectric test of auxiliary wiring to earth
Sweep frequency response analysis
o Type Test
Induce overvoltage test
Lightning Impulse
Temperature rise test
Partial Discharge
Pressure test
Oil leakage test
Vacuum test
o Quality Record
Certificate/test report of main raw material and accessories
Certificate/test report for measuring and protection
MDR (Manufacturing Document Records)

o
o
o

Final Inspection
Packing and Transportation
References International Standard
IEC International Electrotechnical Commission
ISO International Organization for Standardization
CENELEC European Committee for Electrotechnical Standardization
Relevant HD & EN European Union (EU) Standard & Specifications
FM Factory Mutual Insurance
Standard References for transformer
IEC 60076, parts 1 to 5 Power Transformer
IEC 60551 Determination of transformer and reactor sound level
IEC 60289 Reactor
IEC 60214, parts 1 and 2 Tap Changer
IEC 60296 Fluids for electrotechnical applications-Unused
mineral insulating oils for transformer and switchgear
ISO 9000 Series Quality Management System Standard
RAL Coating/Varnish
Amendments Amendments to any of above by local regulatory
bodies

As inspector for Medium Voltage Cable


o Construction Test
Material every layer
Number of wire and shape of conductor
Construction of core
Color or code of insulation
Printing or marking or embossing
o Dimension Test
Diameter
Thicknes
Insulation
Sheath
Flat
o Flame Retardant Test
o Insulation Resistance
o Conductor Resistance Test
o High Voltage Test
o Partial Discharge Test
o High Voltage Test
o Hot Set Test
o Standard Reference for Medium Voltage Cable
IEC 60502-2 Construction test for medium voltage cable
IEC 60540 - Dimension test for medium voltage cable
IEC 60332-3/C Flame retardant test
IEC 60502-2 Insulation test for medium voltage cable
IEC 60502-2 Conductor resistance test
IEC 60502-2 High voltage test
IEC 60502-2 ; IEC 60885-2 ; IEC 60885-2 Partial discharge test
IEC 60502-2 Electrical test
IEC 60811-2-1 Hot set testy

Inspection Assignment
As inspector for medium voltage cable at Prysmian Cable- Bechtel Project
As inspector for control panel of HVAC system at Uni Makmur Elektrika-Sumitomo Project
As inspector for low voltage switchgear at Siemens Indonesia-SNC Lavalin Project
As inspector for power transformer at Pauwels Trafo Asia-Bahrain & TNB Malaysia Project
As inspector for the medium voltage cable at Sucaco-Sumitomo Project
As inspector for the medium voltage cable at Sumi Indo Cable-Sumitomo Project
As inspector for distribution transformer at Unindo Areva-Bechtel Project
As inspector for the medium voltage cable at Kabel metal-Sumitomo Project
As inspector for medium voltage switchgear at Schneider-SDE Malaysia Project
As inspector for low voltage switchgear at Schneider-SDE Malaysia Project
As inspector for the medium voltage cable at Sucaco-Sumitomo Project
As inspector for low voltage switchgear at Uni Makmur Elektrika-Sumitomo Project
TRAINING:
Profibus operation, installation and configuration
Programming, Operating & Maintenance Siemens S7 DCS
PLC Omron C1000H
PLC Mitsubhisi
Instrumentation & Transmitter
Motor Drive: Stepper, Servo, Inverter
PLC Siemens S5 by Siemens Indonesia
PLC Siemens S7 by Siemens Indonesia
Instrumentation & PID Controller
Caterpillar Diesel Engine Repair & Maintenance
Cummins Diesel Engine Repair & Maintenance
Medium Voltage Power Transformer 20 kV
Medium Voltage Switch Gear 20 kV
Low Voltage Switch Gear
Motor Control Center
Capacitor Bank
HVAC System (Heating Ventilation Air Conditioner)
AHU System (Air Handling Unit)
Rotary Drive System & Maintenance
Vibration Analysis
Lubrication Function & Property
RCM (Reliability Center Maintenance)
TPM (Total Productive Maintenance)
5 S Fundamental for Manufacturing

PERSONAL STRENGTHS:
Strong leadership and managerial skill with the experience at the senior manager level, a good
understanding manufacturing process, scientific and technological development
Experiences in the strategic planning, business development and working effectively with
diversified task
Ability to achieve a good balance between working within the parameter of a statutory body
and operating prudent commercial principle
Vision, dynamism and sense of commitment and mission to support the technological
advancement
Skill full of management & development its staff and enhances its facility, capital and
technology project.

WORK EXPERIENCES:
1989 - 1990
PT. Fibertek Abadi Indonesia Honkong MNC.
Specialization: Engineering,
Industry: Textile
As Electrical Engineer
Responsibilities:
Maintenance Task:
Manufacturing process textile equipment:
Diesel engine generator.
Power distribution 20 KV to 380 V
HVAC system +AHU for special room with accurate temperature & humidity
Chiller, Boiler, Air Compressor, Process Water.
Waste Water Treatment
Building of Manufacturing, Office, Warehouse, Social Facility
PLC, Touch Screen Panel, SCADA, Electrical control
DCS, MIS, PLC, Touch Screen Panel, SCADA, Electrical control
Field bus communication, Device net communication, Control net communication & Ethernet
communication
Project Completed:
1. Relocation Textile Factory from Hong Kong to Indonesia
2. Extension Factory Capacity

1990 - 2010
PT. United Can Company
Specialization: Instrumentation, Electrical, Mechanical, Automation, Utility.
Industry: Can Manufacture
As Assistance Manager
Responsibilities:

Operating, Maintenance, & Trouble Shooting:


1. Production Machinery
2. Power distribution 20 KV to 380 V, including design of powerhouse completed with interlock
power back up from diesel engine 1500 KVA
3. Chiller, Boiler, Air Compressor, Process Water.
4. Waste Water Treatment
5. Building of Manufacturing, Office, Warehouse, Social Facility
6. PLC, Touch Screen Panel, Small SCADA, Electrical control
7. DCS, MIS, PLC, Touch Screen Panel, SCADA, Electrical control

Project Completed:
1. Factory Extension
2. Power House Up-grading
3. Utility Up-Grading

Anda mungkin juga menyukai