Dear Sir,

With reference to the subject, please be advised you as follows.


First of all, the oil temperature has to control within 2 from setting temperature.
Otherwise, the circulation line back pressure for water detection (about 1.0 ~ 1.6
kg/) fluctuate very widely, if that happens, the purifier carry out the sludge discharge
very frequently by abnormal water detection.
Besides, in case the fuel oil contains too much water & sludge, it is very difficult that
the purifier in Clarifier Mode (Hidens Mode) operate in normal continuously because
very frequent hidens discharge by separated water & sludge from the dirty oil.
In Case the heavy liquid outlet pressure is over 0.5 MPa like as a subject vessel, the
Multi-Monitor display Error 2 and the Auto Control Panel occur the leakage Alarm.
So, please check the following points.
1) Check the check valve (Symbol-341, Dwg No.S206353) on circulation line for
clogging or sticking
2) Check the Gravity Disc size (GH 109mm with a small hole 3.5mm) and for a crack.

Check Valve (341)

Circulation Line

3) Check the O-ring (Symbol-311, 315, Dwg No.S206353) for a damage or losso
elasticity.
4) Check the Nut (Symbol-320, Dwg No.S206353) & Socket Set screw (Symbol-313,
Dwg No.S206353).
-

the Nut (Symbol-320, Dwg No.S206353) have to tight with 1000 kg.cm (100
Nm)

Dont tight the Socket set screw (Symbol-313, Dwg No.S206353) before the
Nut (Symbol-320, Dwg No.S206353) tight as above.

If there is not solved the problem by above instruction ,we recommend that the
Purifier operation Mode should be temporarily changed from Hidens Mode (Clarifier
Mode) to Purifier Mode as following instruction.
Hidens Mode (Clarifier Mode) is designed for HFO over sp gravity 0.991 at 15, but
Purifier Mode can be treated by maximum specific gravity 0.991 at 15 of Heavy Fuel
oil. (For safe operation without overflow, we recommend maximum specific gravity
0.985 at 15)
1. Change the gravity disc by selection nomogram.
Model SJ120GH: 116 mm (in case of sp. gravity 0.98 at 15 )
2. Fully Close the Needle valve (Sumbol-340, Dwg No.S206353) attached to purifier
and fully open the shut off valve (Symbol-337, Dwg No.S206353).
3. Set the Water Detector selector dial of Multi-Monitor to No Water / heavy liquid
detector function position and the Water Detection output switch to OFF.

4. Change the set value of below timer for Auto Control Panel.
Model SJ120GH
Timer No. 02 : 29 sec
Timer No. 03 : 32 sec
5. Flow rate : 4000 ~ 6000 L/H
6. Treating Temperature : 95 ~ 98
7. Outlet Press : 0.18 MPa

9. Circulation line back pressure for Hidens : No use


Caution!
During feeding operation, if you want to perform the manual sludge discharge, you
have to only perform the total discharge by press the "DIS-T" button twice in 5 seconds.
If the purifiers carry out the partial discharge by press the "DIS-T" button once, the oil
will be overflowed to water outlet pipe (Heavy Liquid outlet).
Best regards,