WZP and WZC series thermal resistance components


Application
WZP and WZPM platinum thermal resistances made by our factory use
imported state-or-art production technology and components. For temperature sensor, its inner quality, structure principle, and appearance are kept in
class A level.
Platinum thermal resistance is a kind of temperature sensor with the feature
of accurate, sensitive, and stable performance. Platinum thermal resistance
components are inner coil structure made of micro ceramic tube for protection
tube, the temperature transducers can be very small (minimum outer
diameter can be 1.6mm), so you can produce different types of micro
temperature sensor probe.

Resistance value at 100 for thermal resistance


temperature transducers (R100) and resistance at 0 (R0)

Working Principle

Diaphragm platinum resistance components

Working principle of platinum thermal resistance: resistance of platinum


resistance wire can be varied under the action of temperature. It can be
directly used to measure the temperature within the range of -200~800.
Its advantages: stable electrical performance, relationship between
temperature and resistance close to linear, with high accuracy.

Main Technical specification


Range specification
Type

Code Graduating Measurement


number
range

Allowed deviation
t

Platinum WZP
Resistance

PT100

-200800

(levelA) -200650allowed
deviation (0.15+0.002|t|)

Platinum
WZP
Resistance

PT100

-200800

(levelB)-200800allowed
deviation (0.30+0.005|t|)

Note: ITI is the absolute value of measured temperature


Allowed difference at level A doesnt adapt to temperature range t>650.
For level A, platinum resistance is allowed for restricted situation.

Heat response time

When temperature changes with stages, output of thermocouple will be


changed to 50% of this stage variation, required time is called heat
response time, represented in t0.5.

Self thermal impact

Max measured current allowed for platinum resistance is 5mA,


temperature rise due to this shall be lower than 0.3.

Ratio: R100/ R0.


Graduating number Pt100: Level A R0 1000.06
Level B R0 1000.12
W100R100/ R01.385

Diaphragm platinum resistance components are imported products with


state-in-art technology in Germany. It have the advantages as accurate,
sensitive, short heat response time, stable quality, long use life, etc. Its
accuracy can reach level 1/3B.

075

076

Jingpu

JINGPU

WZP and WZC series thermo resistance components


Mica platinum resistance components, cooper resistance components
Type of thermal Product
Model
resistance
d

Single platinum
thermal resistance WZP-010
temperature
transducers

l0

Dual platinum
thermal resistance WZP2-010
temperature
transducers

l1

WZP-010
WZP-011

Spec.
Measurement Graduating Material of
range number
protection Diamete Total length l0
tube
d(mm) L(mm)
(mm)
300
External
350
protective layer
-200420 Pt100 1Cr18Ni9Ti 12
450
85
stainless
550
steel sheet
650
900
External
1150
protective layer
-200420 Pt100 1Cr18Ni9Ti 12
85
1400
stainless
1650
steel sheet
2150
External
protective layer
300
8
-200420 Pt100 1Cr18Ni9Ti
stainless
steel sheet
350
65
External
protective layer
450
1Cr18Ni9Ti
8
-200420 Pt100
stainless
steel sheet
550
300
350
450
550
copper
-50100
Cu50
8
tube
650
900
1150
1400
1650
2150

105

60

105

60

80

30

platinum thermal
resistance temperature
transducers

WZP-011

Dual platinum
thermal resistance
temperature transducers

WZP2-011

Cooper thermal
resistance temperature
transducers

WZC-010

Platinum thermal
resistance temperature
transducers

WZP-035

-50150

Pt100

stainless
steel
sleeves

535

35

Cooper thermal
resistance temperature
transducers

WZC-001

-50100

Cu50

stainless
steel
sleeves

300

25

30

Note: WZP-0.35 accuracy level is B.

l0

105
L

WZC-010

Heat
response
l1
time 0.5(S)
(mm)

WZP-035
WZC-001

90

077

Jingpu

JINGPU

WZP and WZC series thermo resistance components


Ceramic platinum resistance components
Model

1.6

15

WZP-012
WZP-013
WZP-014
WZP2-014
WZP-015
WZP-016
WZP2-016
WZP-017
WZP2-017
WZP-018
WZP-019
WZP-020
WZP2-020
WZP-203
WZP-205

20

WZP-012

3
200

32

WZP-013

Graduating
number
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100
Pt100

3.2

15

Measurement
range
-200800
-50150
-200800
-200800
-50150
-200600
-200600
-200600
-200600
-200600
-200800
-200800
-200800
-50150
-50150

Accuracy Heat response Material of sleeve


level
time t0.5(s)
Level A/B
0.2
Ceramic
1Cr18Ni9Ti
Level B
2
Ceramic
Level A/B
0.5
Level A/B
Ceramic
0.5
Level B
5
1Cr18Ni9Ti
Ceramic
Level A/B
0.8
Ceramic
Level A/B
0.8
Level A/B
0.5
Ceramic
Level A/B
Ceramic
0.5
Ceramic
Level A/B
0.2
Ceramic
Level A/B
0.5
Level A/B
0.5
Ceramic
0.5
Level A/B
Ceramic
5
1Cr18Ni9Ti
Level B
Level B
1Cr18Ni9Ti
5

22

15

WZP-014

4.6

15

22

30

WZP-016
WZP2-016

WZP-019

2.8

5
200

32

15

32

WZP-020
WZP2-020

WZP-015

M6

200

WZP-203

15

35

30

WZP-017
WZP2-017

1.6

M8

25

3
200

WZP-205

35

25

15

12

WZP-018

078

Jingpu

JINGPU

WZP and WZC series thermo resistance components


End platinum resistance components
Model

Graduating
number
WZPM-0110
Pt100
Pt100
WZPM-2012

Measurement
range
-50150
-50150

Accuracy Heat response Material of sleeve


time t0.5(s)
level
levelB
1Cr18Ni9Ti
5
1Cr18Ni9Ti
levelB
10

M121.5

10
200

8
200

10

WZPM-2012

WZPM-0110

Platinum resistance components with ceramic connection board


Graduating Measurement Accuracy eat response Length L
number
range level
time t0.5(s) (mm)
225
250
WZP-106
Pt100 -200500 A/B
15
300
350
400
450
550
WZP2-106 Pt100 -200500 A/B
15
650
900
1150
Model

WZP-106

Structure

Temperature measurement
portion:sheathed temperature
sensitive bodyCold end:
ceramic connection board
riveted and with vibration
damper flexible unit

Note: can be used as changeable components of assembly platinum resistance.

R1

6
L0=L+20

Single wiring diagram

R2
3

WZP2-106

Safety Warning

6
L0=L+20

For safety reason, please select the products with proper model, if the
type-chosing or usage of the products is improper, property loss or body
damage may be caused. Designers and users of the system shall take
the responsibility to select proper products and use the products
according to correct methods.

Dual wiring diagram

Shanghai Jingpu Instrument Factory


Shanghai Jingpu Mechanical & Electrical Technology Co., Ltd.
Tel:021-56618282
Fax:021-56618080
Http://www.jingpu.com
E-mail:info@jingpu.com

Anda mungkin juga menyukai