Rexroth ServoDyn D
Connectivity Manual
Mounting guidelines
1070066030
Edition 06
II
Title
Rexroth ServoDyn D
Connectivity Manual
Type of Documentation
Mounting guidelines
Document Typecode
Purpose of Documentation
Record of Revisions
ServoDyn D
1070066030 / 06
DOK-SERV*D-IF*MANUAL**-MA06-EN-P
The present manual provides information on the installation of the
ServoDyn D drive modules.
Description
Release
Date
DOK-SERV*D-IF*MANUAL**-MA06-EN-P
08.2004
Notes
Copyright
Validity
Published by
Bosch Rexroth AG
Postfach 11 62
D-64701 Erbach
Berliner Strae 25
D-64711 Erbach
Tel.: +49 (0) 60 62/78-0
Fax: +49 (0) 60 62/78-4 28
Abt.: BRC/ESM11 (WE)
1070066030 / 06
ServoDyn D
Contents
Contents
Page
Safety instructions . . . . . . . . . . . . . . . . . . . . .
11
21
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting of VMW..F / DMW..F with water cooling . . . . . . .
Cooling water connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cold module installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Link connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMA..K und DM..K . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VMA..B,C,D and DMA..A,B,D with backplane modules . .
VMW..F and DMW..F with water cooling . . . . . . . . . . . . . . .
DC link connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Protective earth connection between the modules . . . . . .
Connection cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
31
34
35
37
38
38
39
310
311
315
316
Connection overview . . . . . . . . . . . . . . . . . . .
41
1.1
1.2
1.3
1.4
1.5
1.6
2.1
2.2
2.3
2.3.1
3.1
3.2
3.2.1
3.3
3.4
3.4.1
3.4.2
3.4.3
3.4.4
3.5
3.6
4.1
4.2
4.3
4.4
4.5
4.6
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Qualified personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety markings on products . . . . . . . . . . . . . . . . . . . . . . . . .
Safety instructions in this manual . . . . . . . . . . . . . . . . . . . . .
Safety instructions concerning the described product . . . .
Documentation, software release and trademarks . . . . . .
Drive components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation compartment . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Layout of the drive components . . . . . . . . . . . . . . . . . . . . . .
Installation in compliance with UL/CSA . . . . . . . . . . . . . . . .
11
12
13
14
15
17
21
24
25
27
41
42
43
44
45
46
VI
ServoDyn D
1070066030 / 06
Contents
5.1
5.2
5.3
5.4
5.4.1
5.4.2
Power connection . . . . . . . . . . . . . . . . . . . . . .
51
5.5
5.6
5.7
5.7.1
5.7.2
Earthing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . .
Earth-leakage circuit-breaker . . . . . . . . . . . . . . . . . . . . . . . .
Mains supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of VMA..KB, VMA..KE (with ballast switch) . .
Connection of VMA..KR, VMA..B,C,D and VMW..F
(with current regeneration) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ballast resistor connection . . . . . . . . . . . . . . . . . . . . . . . . . . .
24 V supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF, SR servo motors power and brake connection . . . . . .
DU asynchronous motor power connection . . . . . . . . . . . .
58
516
517
519
520
529
61
6.1
6.1.1
6.1.2
6.2
6.2.1
6.2.2
7.1
7.1.1
7.1.2
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.9.1
7.10
7.11
7.12
51
53
54
55
56
617
DM control connections . . . . . . . . . . . . . . . .
71
61
62
65
68
69
71
72
76
77
710
716
720
728
732
733
734
735
739
741
750
1070066030 / 06
ServoDyn D
Contents
Application instructions . . . . . . . . . . . . . . . .
81
81
84
86
87
89
812
812
813
814
Personality module . . . . . . . . . . . . . . . . . . . .
91
10
Dimensioned drawings . . . . . . . . . . . . . . . . .
101
8.1
8.1.1
8.1.2
8.2
8.3
8.4
8.5
8.5.1
8.5.2
8.5.3
10.1
10.1.1
81
10.3
10.4
10.5
10.5.1
10.5.2
10.5.3
10.5.4
10.6
10.7
10.8
10.9
11
Part numbers . . . . . . . . . . . . . . . . . . . . . . . . . .
111
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A1
10.2
11.1
11.2
11.3
11.4
A.1
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories for built-in motors . . . . . . . . . . . . . . . . . . . . . . .
Spare fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
101
102
103
104
105
106
106
107
108
109
1010
1011
1014
1014
111
113
113
113
A1
VII
VIII
Contents
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
11
Safety instructions
Safety instructions
Please read this manual before commissioning the ServoDyn D inverters. Store this manual in a place to which all users have access at any
time.
1.1
Intended use
This manual contains information required for the intended use of this
product.
The drive inverters described
D have been developed, manufactured, tested and documented in
compliance with the safety standards. These products pose no
danger to persons or property if they are used in accordance with the
handling stipulations and safety notes prescribed for their configuration, mounting, and proper operation.
D comply with the requirements of
D the EMC Directives (89/336/EEC, 93/68/EEC and 93/44/EEC)
D the EMC product standard EN 61800-3 + A11
D the Low-Voltage Directive (73/23/EEC)
D the harmonized standards EN 50178 (VDE 0160) and EN
60146-1-1 (VDE 0558-11)
D are designed for operation in industrial environments, i.e.
D no direct connection to public low-voltage power supply,
D connection to the medium- or high-voltage system via a transformer.
In residential environments, in trade and commerce as well as small
enterprises class A equipment may only be used if the following warning is attached:
12
ServoDyn D
1070066030 / 06
Safety instructions
1.2
Qualified personnel
The requirements as to qualified personnel depend on the qualification
profiles described by ZVEI (central association of the electrical industry)
and VDMA (association of German machine and plant builders) in:
Weiterbildung in der Automatisierungstechnik
edited by: ZVEI and VDMA
MaschinenbauVerlag
Postfach 71 08 64
D-60498 Frankfurt.
The present manual is designed for drive technicians.
Programming, start and operation as well as the modification of program
parameters is reserved to properly trained personnel! This personnel
must be able to judge potential hazards arising from programming, program changes and in general from the mechanical, electrical, or electronic equipment.
Interventions in the hardware and software of our products, unless described otherwise in this manual, are reserved to our specialized personnel.
Tampering with the hardware or software, ignoring warning signs attached to the components, or non-compliance with the warning notes
given in this manual may result in serious bodily injury or material damage.
Only electrotechnicians as recognized under IEV 826-09-01 (modified)
who are familiar with the contents of this manual may install and service
the products described.
Such personnel are
D those who, being well trained and experienced in their field and familiar with the relevant norms, are able to analyze the jobs being carried
out and recognize any hazards which may have arisen.
D those who have acquired the same amount of expert knowledge
through years of experience that would normally be acquired through
formal technical training.
With regard to the foregoing, please note our comprehensive range of
training courses. Please visit our website at http://www.boschrexroth.com for the latest information concerning training courses, teachware and training systems. Personal information is available from our
Didactic Center Erbach,
Telephone: (+49) (0) 60 62 78-600.
1070066030 / 06
ServoDyn D
Safety instructions
1.3
13
14
ServoDyn D
1070066030 / 06
Safety instructions
1.4
DANGER
This symbol is used wherever insufficient or lacking compliance with
instructions may result in personal injury.
CAUTION
This symbol is used wherever insufficient or lacking compliance with
instructions may result in damage to equipment or data files.
1070066030 / 06
ServoDyn D
15
Safety instructions
1.5
DANGER
Danger for persons and equipment!
Test every new program before starting up a system!
DANGER
Retrofits or modifications may adversely affect the safety of the
products described!
The consequences may include severe injury, damage to equipment, or environmental hazards. Possible retrofits or modifications to the system using third-party equipment therefore have to
be approved by Rexroth.
DANGER
Health hazards through destroyed electrical components!
Do not destroy any built-in components. Dispose of destroyed
components in a proper manner.
DANGER
Do not look directly into the LEDs in the optical fiber connection.
Due to their high output, this may result in eye injuries.
When the inverter is switched on, do not look into the LED or the
open end of a short connected lead.
DANGER
Please note your local, system-specific regulations and requirements as well as the proper use of tools, hoisting and transport
equipment as well as the applicable standards, regulations, and
accident prevention regulations.
16
ServoDyn D
1070066030 / 06
Safety instructions
CAUTION
Use only spare parts approved by Rexroth!
CAUTION
Danger to the module!
All ESD protection measures must be observed when using the
module! Prevent electrostatic discharges!
The following protective measures must be observed for modules and
components sensitive to electrostatic discharge (ESD)!
D Personnel responsible for storage, transport, and handling must have
training in ESD protection.
D ESD-sensitive components must be stored and transported in the
prescribed protective packaging.
D ESD-sensitive components may only be handled at special ESDworkplaces.
D Personnel, working surfaces, as well as all equipment and tools
which may come into contact with ESD-sensitive components must
have the same potential (e.g. by grounding).
D Wear an approved grounding bracelet. The grounding bracelet must
be connected with the working surface through a cable with an integrated 1 MW resistor.
D ESD-sensitive components may by no means come into contact with
chargeable objects, including most plastic materials.
D When ESD-sensitive components are installed in or removed from
equipment, the equipment must be de-energized.
1070066030 / 06
ServoDyn D
17
Safety instructions
1.6
Documentation
The present manual provides information on the installation of the
ServoDyn D drive modules.
Part no.
German
English
French
Italian
1070066 004
1070066 024
1070066 048
1070066 046
Asynchronous motors DU
1070066 007
1070066 027
ServoDyn D, Configuration
- Manual for overview and rating
1070066 009
1070066 029
1070066 059
1070066 049
1070066 010
1070066 030
1070066 060
1070066 050
ServoDyn D,
- Parameter manual (without CANopen)
1070066 018
1070066 038
1070066 068
1070066 058
ServoDyn D, Servodyn-M
- Parameter manual CANopen
1070066 094
1070066 095
1070066 011
1070066 031
1070066 051
1070066 014
1070066 034
1070066 017
1070066 037
1070066 015
1070066 035
1070066 090
1070066 091
ServoDyn D
Frequency inverters DM/DS..8001 (ASM)
Parameter and commissioning manual
1070066 008
1070066 028
1070066 053
Diagnostics, maintenance
1070066 012
1070066 032
1070066 062
1070066 052
1070066 006
1070066 026
1070066 081
1070066 082
EMC manual
1070066 072
1070066 074
1070066 075
1070066 076
1070066 077
1070066 080
Manuals
Release
D The current software release number can be viewed by selecting
parameter S-0-0030 with the DSS-D Commissioning and Service
System, or in the Software field of the module configuration display
(DIAGNOSTICS " MODULE CONFIGURATION).
D For information concerning the current DSS software release, refer to
HELP " ABOUT...
18
ServoDyn D
1070066030 / 06
Safety instructions
D The current VM..B,C,D,F software release can only be read from the
7-segment display during test operation. For this purpose, turn dip
switch T on the VMs personality module on:
The following appears in a running, flashing display:
Cxx.ZZ.ddmmyyyy
Where:
xx
ZZ
dd
mm
yyyy
Trademarks
All trademarks of software installed on Rexroth products upon delivery
are the property of the respective manufacturer.
Upon delivery, all installed software is copyright-protected. The software
may only be reproduced with the approval of Rexroth or in accordance
with the license agreement of the respective manufacturer.
MS-DOSr and Windowst are registered trademarks of Microsoft
Corporation.
PROFIBUSr is a registered trademark of the PROFIBUS Nutzerorganisation e.V. (user organization).
SERCOS interfacet is a registered trademark of Interessengemeinschaft SERCOS interface e.V. (Joint VDW/ZVEI Working Committee).
1070066030 / 06
ServoDyn D
21
2.1
Drive components
22
ServoDyn D
1070066030 / 06
The backplane modules also bear the fan units for heat sink ventilation
of the inverter modules.
The supply modules and three-phase modules are slotted into the
backplane modules, plugged into the terminal blocks and locked.
Supply module Type VMA..K
The VMA..K supply module is directly connected to 3 x 400...460 VAC
using the line wiring module. It generates a d.c. link voltage of 670 V
from the mains voltage.
The link connection to the DM..K three-phase modules is established
via covered conductor bars.
Supply module Type VMA..KR
The VMA..KR supply module is connected to the 3 x 400...460 VAC via
the mains connection module and the line reactor. It generates a d.c.
link voltage of 670 V from the mains voltage.
The link connection to the DM..K three-phase modules is established
via covered conductor bars.
Supply modules Type VMA...B,C,D
The supply modules VMA..B,C,D are connected to the 3 x 400...460 V
AC via the mains connection module and the line reactor. They generate a d.c. link voltage of 670 V from the mains voltage.
The link connection to the three-phase modules DMA..A,B,D is established via conductor bars integrated in the backplane modules. When
combined with DM..K in compact mechanics, the d.c. link connection is
achieved with the d.c. link connection accessory.
Supply module Type VMW..F
The VMW 180F supply module is designed for a maximum output of
120 kW and equipped with an integrated water cooling. It is directly connected to the 3 x 400...460 VAC mains network via the mains connection module and the line reactor.
The DC link connection to the three-phase current modules is made by
covered current bars. If combined with modules without water cooling,
the DC link connection must be made using the DC link accessory including a fuse.
1070066030 / 06
ServoDyn D
23
24
ServoDyn D
1070066030 / 06
2.2
Installation compartment
The ServoDyn D inverter modules are installed in a switch cabinet.
Their component depth is fairly low, i.e. 270 mm or 290 mm, depending
on the mechanics.
The switch cabinets must at least conform to the IP 54 protection standard (dust filter in front of the air inlet and air outlet).
The inverters are mounted in a vertical position with the terminals to the
bottom.
The cooling air flow passes through the modules from the bottom to the
top and must not be obstructed by other switch cabinet components or
parts. In addition, a minimum clearance of 100 mm should be provided
both above and below the inverter.
No minimum lateral clearance need be provided.
The air temperature inside the cabinets may be between 0...+55 _C (derating above 45 _C).
+55 _C is the maximum permitted supply air temperature for the uppermost inverter if several inverters are stacked one above the other.
Constructive measures have to be taken to ensure the appropriate air
flow direction in the switching cabinet in this case.
CAUTION
Danger for product!
The ambient air must be free from high concentrations of dust,
acids, alkalis, corrosives, salts, metal vapors etc.
Condensation on the modules is not permitted!
1070066030 / 06
ServoDyn D
25
2.3
Control lines
Switch cabinet
Power cables
D The mains supply cable is connected to the top side of the NAA or the
NV module.
D The motors power cables are connected to the bottom side of the
module. They should enter the switch cabinet from the bottom.
D Control lines to the modules front connectors are led upward into a
cable duct on the top side of the inverter module.
26
ServoDyn D
1070066030 / 06
NC
PLC
Mains supply
cable
3 x 400 V
Space
for the
mains
filter
Interface
EMC barrier
Signal cables
motor encoder
and
direct measuring
system
NA
VM..D
DM..D
Power cables
motors
Line reactor
(base
mounting)
1070066030 / 06
ServoDyn D
27
2.3.1
For available components with UL/CSA approval, refer to ServoDyn D, Configuration manual, part number on page 17.
28
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
31
Installation
Installation
3.1
Standard installation
All inverter modules are installed in a vertical position with the terminals
to the bottom. They should be connected on a level metal surface using
two or four screws or bolts depending on size. The recommended size is
M5. A conductive connection to the mounting surface must be established via the screws or bolts.
VMA..K / DM..K
The modules in compact mechanics and the NV line wiring module are
directly mounted, all electrical connections can be plugged in.
Combination with DMA..A,B,D modules is possible.
Dimensions in mm:
R 3.25
10.5
R2
NV
VMA..KB(E)
115
99
50
75
DM 45K
2 x DM..K
49
49
DMA..A
74
50
50
50
50
25
50
50
50
50
25
50
25
50
75
534
486
430
445
48
R 7.5
56
The distance between the line wiring module NV and the supply
module must be 25 mm when installing the units.
Otherwise, the mains filter in the line wiring module will heat up too
much if the supply module is continuously operated at nominal
load, resulting in reduced performance data.
32
ServoDyn D
1070066030 / 06
Installation
VMA..KR / DM..K
The modules in compact mechanics, the NAA mains connection module and the NE line reactor are directly mounted, the electrical connections at the inverters can be plugged in.
Combination with DMA..A,B,D modules is possible.
Dimensions in mm:
10.5
R 3.25
R2
NE 21/B
NAA 21
115
115
50
100
VMA 21KR
99
2 x DM..K
49
50
50
50
50
50
50
50
50
49
50
74
50
25
50
25
25
50
100
50
445
430
R 7.5
The distance between line reactor NE 21/B and the mains connection module NAA must be 25 mm when installing the units.
Otherwise, the mains filter in the mains connection module will
heat up too much if the line reactor is continuously operated at
nominal load, resulting in reduced performance data.
1070066030 / 06
ServoDyn D
33
Installation
VMA..B,C,D / DMA..A,B,D
You only need the backplane modules and the NAA module for installation. Combination with DM...K modules is possible.
R3.25
R7.5
115
50
49 49
DM...K
445
RM../DM
RM../VM
486
7.5
NAA: 521.5
RM: 522.5
NAA
430
48
Top mounting
50
A
50
A
50
Module
type
A
50
50
Bottom mounting
50 50
10.5
R2
Dimens.[mm]
A
B
50
RM B/VM
RM C/VM 100
RM D/VM 150
100
150
200
RM A/DM
RM B/DM 50
RM D/DM 150
50
100
200
34
ServoDyn D
1070066030 / 06
Installation
3.2
R 7.5
299
250
299
250
150
199
50
21.6
24.5
R 3.25
Supply module
VMW 180F
50
Three-phase module
DMW 290F
VMW and DMW are equipped with water cooling. They are installed together with a standard NAA module.
489
550
566
51
7.5
1070066030 / 06
ServoDyn D
35
Installation
3.2.1
18.5
Connecting sleeve
M16 x 1.5,
external thread
87.6
Material No.:
Steel 1.4571
The cooling water is connected to the stainless steel fitting M16 x 1.5
(material no. 1.4571) on the back side of the inverters:
D In order to avoid contact corrosion, please do not use any screwed
joints containing nickel, copper, brass or steel. We recommend stainless steel or chromium-plated designs.
D In order to avoid the formation of algae, do not use any transparent
tubing.
D Regularly remove any type of deposits inside the water lines.
Any air remaining in the heat sink will be washed out, venting is not
necessary.
36
ServoDyn D
1070066030 / 06
Installation
Operating conditions
D
D
D
D
D
10...40_C
min. 5 l/min
max. 5 bar
max. 0.6 bar
fs = 8 kHz 6 K/100 A
fs = 4 kHz 4 K/100 A
4.5 K/100 A
Water quality
In order to guarantee safe operation, the cooling water must satisfy the
following conditions regarding soluble chemicals and insoluble substances:
D Concentration of hydrogen ions: pH 7...9
D Total hardness Dmax:
10_ (German)
(1_ German = 1.25 Engl. deg. = 1.05 US degrees = 1.8 French degrees)
D Chlorides:
max. 20 mg/l
D Nitrates:
max. 10 mg/l
D Sulfates:
max. 100 mg/l
D Insoluble substances:
max. 250 mg/l
D Specific resistance:
min. 2000 W/cm
Tap water will in most cases satisfy these requirements.
If your tap water has inadmissible properties, a closed cooling water circuit must be used in which the cooling water can be permanently
checked.
The water inlet temperature should not be below 20 _C. Condensation on the water-conducting components, particularly the power
semiconductors, should be avoided.
Failures that are due to the bad cooling water quality, or damages
caused by condensation, are not covered by the guaranty.
1070066030 / 06
ServoDyn D
37
Installation
3.3
Design IP 20
The special design without sealing against the inside of the switch cabinet (protection standard IP 20) must be cooled with an enclosed ventilation system in order to guarantee the switch cabinets protection
standard IP 54.
Height 406.25
Width = VM + n x DMA + 3
Backplane cut-out
38
ServoDyn D
1070066030 / 06
Installation
3.4
Link connection
The d.c. link voltage generated by the supply module is transmitted to
the three-phase module via conductor bars.
3.4.1
C
D
CAUTION
Tighten the d.c. link joints with 3 Nm to protect the power unit.
1070066030 / 06
ServoDyn D
39
Installation
3.4.2
CAUTION
Tighten the d.c. link joints with 5 Nm to protect the power unit.
310
ServoDyn D
1070066030 / 06
Installation
3.4.3
The DC link connection is made on the bottom side of the modules using
the current bars provided:
1. Insert current bars into terminals C and D and tighten them firmly.
2. Put the plastic cover from the accessories over the current bars and
screw it down to the metal brackets provided.
Fastening
screws
DMW 290F
DC link cover
Fastening
screws
Current bars
DC link
CAUTION
Tighten the d.c. link joints with 18 Nm to protect the power unit.
1070066030 / 06
ServoDyn D
311
Installation
3.4.4
DC link connection
The DC link connection (DC link) is an externally accessible DC link terminal, via which the DC link can be flexibly extended. Possible options:
D CD link on the right, left (for backplane modules)
D DC link for compact mechanics, on the right, left
D DC link connection with integrated fuse (for water-cooled modules).
Module combination
DC link option for combining modules with compact mechanics and
modules with a backplane module.
The DC link connection is available for compact mechanics and for
backplane modules, for both left-sided and right-sided installation.
VM 21K
DMA..A DM..K
NAA
DM..K
DM..A
VM 35
312
ServoDyn D
1070066030 / 06
Installation
1070066030 / 06
ServoDyn D
313
Installation
DC link with integrated fuse option for combining water-cooled modules and other modules.
NAA 180
VMW ..F
DC link
with integrated fuse
The fuse of the DC link connection with integrated fuse must match
the service conditions of the module combination. A 100 A fuse is
delivered together with the unit.
1.
3.
2.
314
ServoDyn D
1070066030 / 06
Installation
1070066030 / 06
ServoDyn D
315
Installation
3.5
VMA..B,C,D / DMA..A,B,D
L
VMA..K / DM..K
L
The protective earth connection between modules in compact mechanics is made using an earth bar at each DM...K and a link at the NV:
1. Release screws of pre-assembled protective earth bar at the module front side, push bar below the fastening screw of the adjoining
module to the left.
2. Reinstall the protective earth conductor bar.
3. Swing link at the mounting side of NV towards VMA...K and screw it
down at both sides.
NV
M6
VMA..K
DM..K
Tightening torque
3 Nm.
316
ServoDyn D
1070066030 / 06
Installation
VMW..F / DMW..F
L
DMW 290F
3.6
Connection cables
The power cables leading to the terminal block should be combined with
strain relief.
Logic cables to the front connectors and power cables must not be laid
together. They may be installed above the inverter module in a cable
duct.
CAUTION
To protect the power unit from destruction, the tightening torque
for the power connections U, V, W must not exceed 12 Nm.
PE
1070066030 / 06
ServoDyn D
41
Connection overview
4.1
Out 1,
relay contact
Option
OM4
X14
X13
X99
Holding
brake
0 V (VM, X332)
+24 V brake*
Point-to-point
terminal
Encoder
simuation
X11
A_Out1+
A_Out1
not used
A_Out2+
A_Out2
0 V brake
X81
Protective circuit
X22
W2
U2
K03
FG FGI
H1
V2
Out5:
n=0
Out6: n = nset
M3
IN5
IN6
IN7
IN8
IN9
IN10
0 V (VM, X332)
X12
Out8
Out9
Plug braking
module option
PE
Out 10,
relay contact
X820
H1
X312
X30
BTB relay
MT
NO
NH
ZT
Mains filter
K1
K1
K1
K1
2 4 6
W1
V1
U1
0 VPWR
24 VPWR
1 3 5
PE L1 L2 L3
Load power
supply unit
NAF relay
X810
12
X331
1
12
X332
1
0 VOut
...
NV
...
10
...
24 VOut
Synchronous motor
X05
X21
A_IN2+
A_IN2
A_IN3+
A_IN3
Out 3
Out 2
X34
RS232
Out 4
Motor
encoder
10
SW+
SW
Setpoint
= LED
From the VM
X331/X332
X06
FG
FG 0V
IN 1
IN 2
IN 3
IN 4
24 VIn
0 VIn
1
1
STA relay
Connection overview
17
42
ServoDyn D
1070066030 / 06
Connection overview
Out 3
Temperature warning
X34
X06
RS232
Out 4
X14
8
Holding
brake
0 V (VM, X332)
Point-to-point
terminal
Encoder
simuation
1
X11
not used
+24 V brake*
0 V brake
X81
Protective circuit
W2
X22
Start/Stop
20
Mode
21
Reference cam
Home position
U2
K03
FG FGI
H1
V2
M3
Block select 24
X12
0 V (VM, X332)
Plug braking
module option
PE
Relay contact
MC status
X820
H1
X312
MT
NO
NH
ZT
X30
BTB relay
Mains filter
K1
K1
K1
K1
2 4 6
W1
V1
U1
0 VPWR
24 VPWR
1 3 5
PE L1 L2 L3
Load power
supply unit
NAF relay
X810
12
X331
1
12
X332
1
0 VOut
...
NV
...
10
...
24 VOut
Synchronous motor
X05
Option
OM4
1
X21
8
X13
Motor
encoder
10
X99
not used
not used
= LED
FG
FG 0V
20
21
Block select
22
23
24 VIn
From the VM
X331/X332
0 VIn
X8
STA relay
17
4.2
1070066030 / 06
ServoDyn D
43
Connection overview
C
1
X34
X14
8
Option
OM4
Holding
brake
0 V (VM, X332)
+24 V brake*
Point-to-point
terminal
0 V brake
X51
Protective circuit
M3
W2
K03
S4
S3
0 V (VM, X332)
FG FGI
H1
S2
V2
U2
C
C
Plug braking
module option
D
D
PE
X810
X820
X312
MT
NO
NH
ZT
X30
BTB relay
Mains filter
K1
K1
K1
K1
2 4 6
W1
V1
U1
0 VPWR
24 VPWR
1 3 5
PE L1 L2 L3
Load power
supply unit
NAF relay
H1
12
X331
1
12
X332
1
0 VOut
...
NV
...
10
...
24 VOut
Synchronous motor
NH
Out 1,
relay contact
8
X13
PROFIBUS
MT
Out 3
Out 2
6
1
X05
10
Motor
encoder
X99
X06
RS232
Out 4
1
X312
STA relay
= LED
DM with PROFIBUS-DP
From the VM
X331/X332
FG
FG 0V
IN 1
IN 2
IN 3
IN 4
24 VIn
0 VIn
X8
STA relay
17
4.3
44
ServoDyn D
1070066030 / 06
Connection overview
X8
17
4.4
T1MOT
T2MOT
X34
6
RS232
n=0/f=0
FGI
relay contact
STA relay
V2
FG FGI
C
C
H3
D
D
H2
TEMP
H1
IGR
IRED
STA
U2
X13
Temp. relay
M3
W2
X820
H1
X312
1
2
X30
Mains filter
K1
K1
K1
K1
2 4 6
W1
V1
U1
0 VPWR
24 VPWR
1 3 5
PE L1 L2 L3
Load power
supply unit
NAF relay
X810
12
X331
1
12
X332
1
0 VOut
...
NV
24 VOut
...
10
...
BTB relay
MT
NO
NH
ZT
Asynchronous standard
motor or high-frequency
spindle
X06
PE
10
From the VM
X331/X332
FG
FG 0V
PLA
PLB
PLC
DCB
24 VIn
0 VIn
= LED
Frequency inverter
X99
Analog
outputs
I 20MA
OUT1
OUT2
OUT0V
X23
SW+
SW
fi < fx
fi = fs
10
Setpoint
I1
I3
1070066030 / 06
ServoDyn D
45
Connection overview
X8
17
1
6
FG FGI
Holding
brake
Synchronous motor
K03
Plug braking
module option
C
X06
10
d.c. link
X99
Out 4
Out 3
Out 2
X34
AE FGI
H1
Out 1,
relay contact
6
X32
W2
V2
U2
W1
V1
U1
L01
16
PE
STA relay
X820
10
X810
RS232
1
X312
8
1
X331
12
1
X332
12
1
K2
K2
2 4 6
1 3 5
Mains filter
option
PE L1 L2 L3
...
NAA
0 V (VM, X332)
NH
NH 0V
ZT
NO
AE
1W1
1V1
1U1
X30
24 VPWR
0 VPWR
Load power
supply unit
M3
V2
U2
...
...
0 VOut
X55
X27
W2
X71
ZT 0V
NH1
SO
SO 0V
ST-S
ST-R
MT
24 VOut
0 V brake
X69
In
...
Option
OM1...4
Motor
encoder
X05
H1
Memory
Card
X72
+24 V brake*
X68
Optical fibre
from NC / PC
Out
Out 1,
relay contact
0 V (VM, X332)
Loop
Out 3
Out 2
X34
RS232
X99
24 VIn
0 VIn
10
From the VM
X331/X332
X06
FG
FG 0V
IN 1
IN 2
IN 3
= LED
STA relay
Out 4
Line reactor
*)
4.5
46
ServoDyn D
1070066030 / 06
Connection overview
C
1
Out 3
Out 2
X34
Out 1,
relay contact
8
X13
X14
8
Option
OM4
0 V brake
Protective circuit
S5
S4
S3
S2
K03
U2
Plug braking
module option
M3
V2
FG FGI
H1
X76
W2
Feedback
Safety relay
X820
X06
C
X99
10
d.c. link
D
X34
AE FGI
H1
Out 4
Out 3
Out 2
Out 1,
relay contact
X32
W1
V1
U1
L01
16
W2
V2
U2
Line reactor
*)
X810
RS232
1
X312
8
PE
STA relay
1
12
X331
X332
K2
K2
2 4 6
1 3 5
Mains filter
option
PE L1 L2 L3
...
NAA
0 V (VM, X332)
NH
NH 0V
ZT
NO
AE
1W1
1V1
1U1
X30
24 VPWR
0 VPWR
Load power
supply unit
...
0 VOut
12
24 VOut
...
10
...
ZT 0V
NH1
SO
SO 0V
ST-S
ST-R
MT
Holding
brake
Point-to-point
terminal
+24 V brake*
Synchronous motor
CAN bus
0 V (VM, X332)
P (24 V PWR)
FG P
FG N
N (0 V PWR)
X05
10
Motor
encoder
X99
X06
RS232
Out 4
X51
= LED
From the VM
X331/X332
FG
FG 0V
IN 1
IN 2
IN 3
IN 4
24 VIn
0 VIn
X8
STA relay
17
NAA, VMW with current regeneration and DMW with CAN bus
1
4.6
1070066030 / 06
ServoDyn D
51
Power connection
Power connection
5.1
Earthing
CAUTION
Inverter modules may only be operated with an earthed neutral
system.
Systems not directly earthed (IT protective system) must not be
used for operation, as air clearances and leakage paths in the module may be overloaded.
Operation at asymmetrical mains systems (TT protective system,
one mains phase is earthed) is not permissible!
DIN VDE 0100-300 defines mains systems subject to their type of earth
connection.
Accordingly, in an IT protective system, all active parts are separated
from earth, or one point is connected to earth via a resistor.
The exposed conductive parts of an electrical system are either
D earthed separately, or
D earthed jointly, or
D jointly connected to the system earth.
52
ServoDyn D
1070066030 / 06
Power connection
DANGER
Dangerous shock currents through inappropriate protective
earth connections!
Do not impair protective earth connections by mechanical,
chemical or electro-chemical influences. The connection must be
firm and lasting.
Earthing scheme
0V bar, insulated
installation
4
Power
supply unit
0V
+24V
4
Separable
for testing
purposes
cf.
page
53
PE
Mains filter
NA
(NV)
at least
identical to
mains feeder
RM
(VM)
RM
(DM)
RM
(DM)
Line
reactor
PE bar
16
= Conductive connection
through housing and
fastening screws
Motor
Motor
For DM...K modules, the earth conductor of the motors is fitted with
a cable lug and squeezed under the fastening screw of the earth
bar.
1070066030 / 06
ServoDyn D
53
Power connection
PE bar
The cross-section of the PE bar and mounting plate earth conductor
must be selected one size bigger than the line feeder of the supply module.
24 V power supply unit
The PE connection and the secondary circuit earthing (non-isolated)
must be designed in accordance with the secondary current, but must
have a cross-section of at least 1.5 mm2.
0 V bar
The 0V bar must have an insulated structure and may be earthed in a
single point only.
This measure is designed to avoid 24V operating currents in the earth
and shield connections.
5.2
Language
Part no.
German
English
French
Italian
54
ServoDyn D
1070066030 / 06
Power connection
5.3
Earth-leakage circuit-breaker
Inverters incorporate switched power units which are always associated with capacitive leakage currents against earth. The leakage currents may depend on the number of inverters, the earthing conditions
as well as the design and length of motor power cables.
Mains filters and shielded cables used to improve the electromagnetic
compatibility (EMC) increase the leakage currents further. For this reason, no earth-leakage circuit-breakers with nominal leakage currents of
less than 300 mA may be used.
DANGEROUS ELECTRICAL VOLTAGE
Personnel protection is only guaranteed if earth-leakage circuitbreakers with nominal leakage currents of less than 30 mA are
used.
The protection of all electrical components connected together with inverters with a 3-phase mains connection to a pulse power current sensitive e.l.c.b. may be adversely affected.
Therefore, you should either install an isolating transformer with a protective device and earthing in the mains feeder, or use a universal current sensitive e.l.c.b. type B which also provides safety disconnection in
the event of DC leakage currents.
1070066030 / 06
ServoDyn D
55
Power connection
5.4
Mains supply
DANGEROUS ELECTRICAL VOLTAGE
The only permissible protective measure in accordance with
EN 50 178 is a protective earth connection.
The protective conductor must at least have the same area as the
mains feeder.
Earthing only one end of the DC link when operating by means of
an isolating transformer is prohibited!
CAUTION
Inverter modules may only be operated with an earthed neutral
system.
Systems not directly earthed (IT protective system) must not be
used for operation, as air clearances and leakage paths in the module may be overloaded.
Operation at asymmetrical mains systems (TT protective system,
one mains phase is earthed) is not permissible!
56
ServoDyn D
1070066030 / 06
Power connection
Autotransformer
If the actual mains voltage is not identical with the specified supply voltage, an isolating transformer or an autotransformer with the following
specifications may be used:
3-phase autotransformer to UL standard
for inverter input
VM
21KR / VM 35B VM 70C VM 90D
21KB,E
8 kHz
8 kHz
8 kHz
8/25 A
10 A
17 A
25 A
Output
16 kW
25 kW
42 kW
60 kW
Primary voltage
8 kHz
125 kW
Secondary voltage
5.4.1
VM W
180F
3 x 400 V
Secondary current
24 A
35 A
70 A
90 A
180 A
Short-circuit voltage uk
1.5 %
1.5 %
1.0 %
0.8 %
0.8 %
Protection standard
IP 00
Insulation class
H/40
CAUTION
In order to protect the VMA..K from damage, a mains filter may
only be installed between the mains contactor and the inverter.
1070066030 / 06
ServoDyn D
57
Power connection
NV 21/1FD
24 VDC
13
21
31
43
A1
F1 F3,
(For spare fuses, refer
to page 113)
K1
22
32
44
Mains filter
K1
14
A2
0V
X73
(only for 24 V circuits)
U1
V1
W1
VM
* According to EN 60204 Part 1/1993, Tab. 5 for installation in the cable duct at an ambient temperature of 45_C
58
ServoDyn D
1070066030 / 06
Power connection
5.4.2
PE L1 L2 L3
L1 L2 L3
Line
Load
L1 L2 L3
U1 V1 W1
NAA..
U2 V2 W2
Mains filter
option
1070066030 / 06
ServoDyn D
59
Power connection
Mains filters are rated for permanent operation at full rated current up to
40_C. In the event of other ambient temperatures, the admissible operating current can be derived from the following diagram.
Wrong !
Right
510
ServoDyn D
1070066030 / 06
Power connection
21
31
U1
1
43
V1
3
W1
5
NAA 21:
NAA 35:
NAA 70:
4 mm2 *
10 mm2
25 mm2
F1 F3,
For type, refer to information given below
5
K1
K2
2
6
R1 R3
Mains filter
option
(standard in
NAA 21)
K2
22
32
X 74
44
U2
Control line to
VM, X32
V2
W2
NAA 21:
NAA 35:
NAA 70:
4 mm2 *
10 mm2
25 mm2
* According to EN 60204 Part 1/1993, Tab. 5 for installation in the cable duct at an ambient temperature of 45_C
Fuses:
NAA 21,
NAA 35,
1070066030 / 06
ServoDyn D
511
Power connection
PE
L1 L2 L3
Mains filter
option
NAA..
U2 V2 W2
Line
reactor
NE
VMA..KR
VMA..B,C
(with current
regeneration)
DM..A,
B,D
DM..K
Motor
Motor
1U1
1V1
1W1
U1 V1 W1
U1 V1 W1
U2 V2 W2
Between the NAA mains connection module and the supply module
with current regeneration a line reactor NE is installed.
The supply module must be considered when choosing the size of the
line reactor (refer to manual Configuration).
The line reactor is equipped with cable ends which can be shortened to
the required length. We recommend using plug connectors for terminal
connection.
CAUTION
A reversed phase sequence or winding direction of a line reactor
will destroy the mains connection module.
Please ensure proper wiring.
512
ServoDyn D
1070066030 / 06
Power connection
NAA 90..-D
21
31
43
F1 F3,
For type, refer to information given below
5
K1
K2
2
6
R1 R3
Additional filter
(only in NAA 90/2.. -D)
Contactor control
and
synchronization
K2
22
32
X 74
44
1U2 2U2
1V2
Control line to
VM X32
via line reactor NE to
VMA 90D
* According to EN 60204 Part 1/1993, Tab. 5 for installation in the cable duct at an ambient temperature of 45_C
Fuses:
NAA 90: 3 x Jean Mller M00f1, very quick acting, 125 A/660 V
(For part numbers, refer to page 113)
1070066030 / 06
ServoDyn D
513
Power connection
L1 L2 L3
Mains filter
option
U1 V1 W1
VMA..90D
2X
line reactor
NE 70A
U1 V1 W1
U1 V1 W1
U2 V2 W2
U2 V2 W2
DM..A,
B,D
DM..K
Motor
Motor
2U1
2V1
2W1
1U1
1V1
1W1
(with current
regeneration)
1W2
2W2
1V2
2V2
1U2
2U2
NAA 90
514
ServoDyn D
1070066030 / 06
Power connection
230 V (110 V)
50/60 Hz
13
21
U1
V1
W1
F1 F3,
For type, refer to information given below
K1
K1
5
K1
K2
2
6
R1 R3
K2
14
Contactor
control
and
synchronization
22
X 73
N
Control line to
VM, X32
1U2 2U2
1V2
0 VAC
35 mm2 *
X 20
via line reactor NE 180 with filter capacitor to
VMW 180F
* According to EN 60204 Part 1/1993, Tab. 5 for installation in the cable duct at an ambient temperature of 45_C
Fuses:
NAA 180: 3 x Jean Mller M00f1, very quick acting, 250 A/660 V
(For part numbers, refer to page 113)
1070066030 / 06
ServoDyn D
515
Power connection
L1 L2 L3
Mains filter
option
U1 V1 W1
1W2
2W2
1V2
2V2
1W2
2W2
W11
W12
W21
W22
W3
DMW
290F
1U2
2U2
1V2
2V2
V11
V12
V3
V21
V22
U21
U22
U3
VMW 180F
(with current
regeneration)
1U1
2U1
1V1
2V1
1W1
2W1
1U2
2U2
4 mm2
U11
U12
NAA 180
Motor
Filter
capacitor
Line reactor
NE 180
The NE 180 line reactor is installed between the mains connection module and the supply module with current regeneration.
A filter capacitor is additionally required. Due to the high surface temperature of the line reactor, the distance between the filter capacitor and
the line reactor must be 1 m min. Cable length 2 m max.
CAUTION
A reversed phase sequence or winding direction of a line reactor
will destroy the mains connection module.
Please ensure proper wiring.
516
ServoDyn D
1070066030 / 06
Power connection
5.5
VMA..KE
U1
V1
W1
R+
2.5 mm2
max. 10 m
1070066030 / 06
ServoDyn D
517
Power connection
5.6
24 V supply
The supply modules require a 24 V supply from an external 24 VDC load
power supply module in accordance with EN 61 131 (20.4 28.8 V). A
stabilized power supply unit is not required.
The input terminals are protected by miniature fuse F1 20 A/32 V.
Spare fuse, part no. 1070 917 667
The 0 VPWR connection is internally floating against ground. If the 0 V
are to be grounded, the ground connection has to be made, e.g., at the
external 24 V power supply unit.
DANGEROUS ELECTRICAL VOLTAGE
The 24 VDC must satisfy the safety separation requirements.
The requirements in accordance with the overvoltage category III
should be noted on the primary side!
DANGER
The drives coast to a standstill if the 24 V supply is interrupted!
This can be avoided by taking one of the following measures:
D use a buffered 24 V power supply unit (no 100% safety)
D plug braking of the motors with KSB (plug braking) module
D use motors with a holding brake.
518
ServoDyn D
1070066030 / 06
Power connection
Due to the cross-connection to the axis modules, the number of inverters that can be connected is limited:
D maximally 9 axes per VM
D maximally 14 A power input (24 VDC) per VM
Module type
Backplane module
VMA 21K
1.0 A
VMA 21KR
2.1 A
VMA 35B
RMB/VM
2.3 A
VMA 70C
RMC/VM
2.7 A
VMA 90D
RMD/VM
3.1 A
VMW 180F
2.5 A
DMA 4K
0.89 A
DMA 8K
0.89 A
DMA 15K
0.89 A
DMA 30K
1.03 A
DMA 45 K
1.4 A
DMA 4A
RMA/DM8
1.0 A
DMA 8A
RMA/DM8
1.14 A
DMA 15A
RMA/DM30
1.14 A
DMA 30A
RMA/DM30
1.23 A
DMA 45A
RMA/DM45
1.32 A
DMA 85B
RMB/DM
1.35 A
DMA 140D
RMD/DM
1.58 A
DMW 290F
2.5 A
max. 14 A
1070066030 / 06
ServoDyn D
519
Power connection
5.7
Motor connection
DANGEROUS ELECTRICAL VOLTAGE
Due to the permanent magnet excitation, the power connector
carries a hazardous high voltage if the rotor is rotating and the
motor is not electrically connected!
The unit must be completely de-energized and halted before commencing any connection or installation work.
Motor cables
Gasket
40
Sealing ring
Clamp
Flange
Housing/Cabinet
520
ServoDyn D
1070066030 / 06
Power connection
5.7.1
Please note that unshielded motor cables may inject voltages into
other cables laid in parallel due to capacitive injection mechanisms.
Noticeable voltages are particularly injected in unused brake
cores. In accordance with IEC 1201, the line capacitance is not
sufficient to generate lethal voltages (at a cable length of 100 m approx. 15 nF between cores, a dangerous value would be 28 nF at
400 V). Insulate the open ends of the brake cores.
If cables are laid in parallel, injection is approx. 10 times lower.
Shielded motor cables do not produce injections.
DM..K
Power connection using plugs at the bottom side of the housing.
U2
V2
W2
1070066030 / 06
ServoDyn D
521
Power connection
DM 45K
Motor connection using terminals at the bottom side of the housing.
U 2 V 2 W2
Front side
DMA..A,B,D
Power connection to terminal block of the RM backplane module using
plug connectors.
Screw tightening torque:
3.0 Nm
U2
X68
V2
W2
X69
(Holding brake)
522
ServoDyn D
1070066030 / 06
Power connection
DMW 290F
Power connection to terminal block at the bottom side using plug connectors.
Screw tightening torque:
12.0 Nm
PE
1070066030 / 06
ServoDyn D
523
Power connection
Motor
M3
Connector
size
Motor connector SF(R)L0, L1, A2, A3,
1
SF(R)A4...015/030
SF(R)B4.0091/0125...
SF(R)B5.0250...
SF(R)A4..060
U
SF(R)B4.0172/0230...
SF(R)A5
SF(R)B5.0460.20
Pin
1 (6-pin)
Pin
1,25 / 1,5
(8-pin)
0V
(X332)
K03
PE bar
Out4
U2
V2
W2
X68
Inverter
X69
DM..K:
Point-to-point terminal from
brake supply filter
Alternatively: Complete
brake connection with relay
and protective circuitryg
524
ServoDyn D
1070066030 / 06
Power connection
1070066030 / 06
ServoDyn D
525
Power connection
0.6Nm 3Nm
X68
X68
526
ServoDyn D
1070066030 / 06
Power connection
DM...K
1070066030 / 06
ServoDyn D
527
Power connection
DM..K
MBC
Control of holding brake
Auxiliary contact
Motor holding brake
24 V relay supply
24 V loop-through
X78
A1, A2
Control
528
ServoDyn D
1070066030 / 06
Power connection
X40
24 V, 0 V
Voltage supply
LED, green
The LED is on if the holding brake of the motor has been vented, i.e.
when control is active.
Key
The brake can be vented using the S key if no external control signal is
present.
1070066030 / 06
ServoDyn D
529
Power connection
5.7.2
Motor end
DMA..A,B,D:
Power connection with plug connectors at the RM backplane module
terminal block. Screw tightening torque
3.0 Nm
External
fan
W2
U2
V2
U1
V1
W1
Holding
brake
option
1
2
DU asynchronous
motor
2U22V22W2
DM..K:
Power connection using plugs at the bottom side of the housing.
2U1
2V1
2W1
Module end
24 V DC
10 %
U2
V2
W2
3 x 400...415 V
10 %,
5060 Hz
PE
RM / DM...K
Star connection,
to be used for motors size 90
D connection,
to be used for motors size 100 ... 160
CAUTION
The contacts of the motor contactor may weld together if opened
under excessive load!
The motor contactor may only be opened when n = 0 and enabling
has been cancelled.
530
Power connection
Notes:
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
61
6.1
..
..
..
..
X
3
1
2
X
3
0
F
1
20A
32V
Fuse F1
20A/32V
(1 x 1070 917 667)
12
..
..
..
..
..
..
X
3
3
2
..
..
..
..
..
..
.. ..
.. ..
X312
8
NAF relay
7
6
BTB relay
5
4 MT
3 NO
2 NH
1 ZT
2 0 VPWR
1 24 VPWR
X332: 1...12 0 Vout
X
3
3
1
H
1
X
8
1
0
X
8
2
0
62
ServoDyn D
1070066030 / 06
6.1.1
Terminal strips
X30.1/2
24VPWR, 0VPWR
0 VPWR
24 VPWR
NA
F
7
6
BTB
X312
X312.1
ZT
+24 V
NAF
relay
+24 V
BTB
relay
MT
NO
NH
ZT
Dead-mans key
NH
1070066030 / 06
ServoDyn D
63
D setpoint-controlled by master
D drive-controlled via ramp P-0-0260 (for SERCOS interface only).
When halted, the torque is removed from all motors.
For connection, cf. page 65.
X312.3
NO
MT
Optocoupler input for the measuring probe of the machine, active with
+24V.
Can be used as a setpoint interface in connection with SERCOS interface only.
The signal is transmitted to the DMs through the X810 module crossconnection. The signal propagation delay between the measuring probe
and the axis in question is < 5 ms.
X312.5/6
BTB
Ready
64
ServoDyn D
1070066030 / 06
X312.7/8
NAF
Mains failure
X331
1
2
3
4
5
6
7
VM..K
24 VOut
8
9
10
11
12
X331
24 VOut
Module supply
X332
0 VOut
Module supply
X332
1
2
3
4
5
6
7
0 VOut
8
9
10
11
12
X331, X332 are the reference potential of the X312 terminal block and
serve for the supply of the interface inputs and outputs at the drive modules.
X331, X332 must be wired to:
all three-phase modules X06.9: 24 VIn
X06.10: 0 VIn
X331 can be loaded with 3 A max. If higher loads are applied, the
current limitation becomes active, and voltage breaks down.
1070066030 / 06
ServoDyn D
65
6.1.2
66
ServoDyn D
1070066030 / 06
Start logically linked for inverters with analog interface, Motion Control, CAN bus,
PROFIBUS-DP
24VDC
43 (NV..D)
STA relay
(axis 1...n)
K1
44 (NV..D)
Ready
EMERGENCYSTOP
Control/PLC
FG
Drive
OFF
FG, X06.3
(Drive enable)
Emergency-Stop switchgear
X312.5 (VM)
BTB
X312.6 (VM)
Drive ON
13 (NV..D)
K1
14 (NV..D)
A1 (NV..D)
Mains contactor K1
V1
A2 (NV..D)
0V
In case of EMERGENCY-STOP, inverters enabled with FG/FGI signal VM switched off with active control (F98).
This message can be acknowledged by setting FG again.
1070066030 / 06
ServoDyn D
67
24VDC
STA relay
(axis 1...n)
Ready
EMERGENCYSTOP
Control/PLC
Drive
OFF
Emergency-Stop switchgear
(Safety contact
delayed opening)
X312.5 (VM)
BTB
X312.6 (VM)
Drive ON
13 (NV..D)
K1
14 (NV..D)
A1 (NV..D)
Mains contactor K1
V1
A2 (NV..D)
0V
In case of EMERGENCY-STOP, inverters enabled with FG/FGI signal VM switched off with active control (F98).
This message can be acknowledged with Reset diagnostics class
1.
68
ServoDyn D
1070066030 / 06
6.2
Supply
inputs/outputs
1
STA relay
2
3 NH
4 NH 0V
5 ZT
6 NO
7 AE
8
9 24 VIn
10 0 VIn
X6
1 Out 4
X34
2 Out 3
3 Out 2
4
5
Out1 relay
6
X32
logic interface
to the NAA module
1 only in the case X312
of RSU*
2 NH1
3
4
only in the
5
case of RSU*
6
7 MT
8
1...12 24 VOut
1...12 0 VOut
24 V module
supply
1 24 VPWR
2 0 VPWR
S1:Power-off delay
of internal enable signal
S
1
Hex switch
Time [sec]
X
0
6
X
3
2
X
3
4
.. ..
.. ..
RS 232 interface
X
9
9
Reset
X
3
1
2
..
..
..
..
X
3
3
1
..
..
..
..
..
..
X
3
3
2
..
..
..
..
..
..
X
3
0
20A
32V
Personality module
X
8
1
0
X
8
2
0
X27:
X
2
7
F
1
H1
X
.. .. 18
.. .. 0
X
8
2
0
d.c.link
D
AE FGI
Fuse F1 20A/32V
(1 x 1070 917 667)
..
..
..
..
..
..
..
..
1,2,3, ... F
1,2,3, ... 15
RSU = redundant
safety control
U2 V2 W2
1070066030 / 06
ServoDyn D
69
6.2.1
Terminal strips
For wiring, see section 6.2.2 .
VM
1
STA
2
X06
STA
relay
+24 V
NH
4
6
NH 0V
ZT
RSU functionality
(refer to RSU manual)
NO
AE
24 VI
n 0 VI
9
10
Supply
inputs/outputs
X06.1/2
STA
Status message
610
ServoDyn D
1070066030 / 06
X06.3/4
NH / NH 0V
Emergency-Stop, channel 2
NO
AE
Drive on / RESET
Display by means of the AE and FGI LEDs
Optocoupler input to switch the drive on and to clear errors on the VM.
Active with +24 V DC (16...30 V), both LEDs illuminate when the drive is
on.
For connection refer to page 617.
AE must be operated for at least 0.1s.
An active error message is cleared if the error has been corrected. If several errors have occurred the error with the higher next priority is then
displayed.
The VM will be automatically activated if no more errors exist and the
Emergency-Stop channels have not been interrupted:
D The mains contactors in the NAA module are switched on
D The d.c. link voltage controller is activated
D VM initiates central enable FGZ
D STA contact is closed.
The On key is controlled against manipulation. The On key is only
switched on by a positive edge if the Emergency-Stop channels remain
uninterrupted.
1070066030 / 06
ServoDyn D
611
X06.9/10
24VIn, 0VIn
Input and output supply voltage at X06 and X34, to be connected to one
of the supply voltage outputs at the VM (X331, X332).
Terminal strip X30
VM
X30
X30.1/2
24VPWR, 0VPWR
24 VPWR
0 VPWR
612
ServoDyn D
1070066030 / 06
X34
Out 4
Overload
Out 3
Mains failure
Out 2
Excess temperature
4
5
6
X34.1
Out 4
Overload
7-segment display:
Out 3
Mains failure
7-segment display:
1070066030 / 06
ServoDyn D
613
CAUTION
If mains failure occurs the VM could switch off the drives without
delay due to overcurrent (supply) or overvoltage (regeneration).
The d.c. link must be immediately boosted (supply operation) or
unloaded (regeneration operation).
X34.3
Out 2
Excess temperature
7-segment display:
or
Cut-off limit
>75C
>80C
Ambient temperature
>45C
>55C
614
ServoDyn D
1070066030 / 06
VM
X312
ZT 0V
NH1
SO
SO 0V
ST-S
ST-R
MT
X312.2
For a description of those terminals which are only needed for the
RSU option, please refer to the RSU, Redundant safety monitoring manual.
NH1
Emergency-stop 1, channel 1
MT
1070066030 / 06
ServoDyn D
615
VM
X331
4
5
6
7
1
2
3
VM
24 VOut
8
9
10
11
12
X332
4
5
6
7
0 VOut
8
9
10
11
12
X331
24 VOut
Module supply
X332
0 VOut
Module supply
X331, X332 provide the reference potential for the X06, X34, X312 terminal strips and supply only the drive modules interface inputs and outputs. X331, X332 should be connected to:
D X06 on the VM:
X06.9: 24 VIn
X06.10: 0 VIn
D X06 on the DMs: X06.9: 24 VIn
X06.10: 0 VIn
X331 can be loaded with 3 A max. If higher loads are applied, the
current limitation becomes active, and voltage breaks down.
616
ServoDyn D
1070066030 / 06
d.c. link
D
1070066030 / 06
ServoDyn D
6.2.2
X331
X332
1
12
0 VPWR
0 Vout
12
3
4
5
6
7
8
9
10
1
2
STA
NH
NH
0V
NO
AE
X06
STA
10
Onbutton
Offbutton
NH1
Positively driven contact of the EmergencyStop switchgear
1
2
3
to PLC
24 VI
n 0 VI
DM
24 V load
power supply
unit
24 Vout
X312
X06
24 VPWR
FG
FG 0V
other enable
conditions (FG)
if necessary
CNC
Ready
617
618
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
DM control connections
7.1
Encoder switch /
Encoder simulation
Digital inputs
Digital outputs
1
2
3
4
5
6
SW+
SW
A_IN2+
not
A_IN2
used
A_IN3+
A_IN3
1
2
3
4
A_Out1+
not
A_Out1
used
A_Out2+
A_Out2
1
2
3
4
5
6
IN5
IN6
IN7
IN8
IN9
IN10
1
2
3
4
5
6
7
8
Out5
Out6
Out7
Out8
Out9
X
0
5
RS 232 interface
X
8
1
X
9
9
X21
X
2
1
X11
X22
X
1
1
X
2
2
X
1
2
X12
Out10
relay
X
0
6
X
3
4
.
.
.
..
.
.
..
.
RESET
.
.
.
..
.
.
.
.
.
.
..
.
1
2
3
4
5
X06 6
7
8
9
10
.
.
.
.
.
.
.
..
.
.
.
.
..
.
X34
H1
FG FGI
..
..
..
..
X
8
1
0
X
8
2
0
STA relay
FG
FG 0V
IN 1
IN 2
IN 3
IN 4
24 VIn
0 VIn
1 Out 4
2 Out 3
3 Out 2
4
Out1
5
relay
6
Digital inputs
Supply
inputs/outputs
Digital outputs
71
72
ServoDyn D
1070066030 / 06
7.1.1
Inputs
D
M
1
STA
2
X06
FG
FG 0V
IN 1
IN 2
6
7
8
9
10
X06.1/2
STA
+24 V
STA
relay
IN 3
IN 4
24 VIn
0 VIn
Supply
inputs/outputs
Status message
FG
External enable
Display via LED FG
1070066030 / 06
ServoDyn D
73
X06.5/6/7
IN 1, IN 2, IN 3
24 V inputs
Optocoupler inputs.
Active with +24 V DC (15...30 V) with regard to X6.10.
Input current typically 17 mA.
Assignment
g
Functionality
Servo function
Positioning function
X06.5
(IN 1)
Block select:
Coded position number
20 (bit 1)
X06.6
(IN 2)
X06.7
(IN 3)
Default setting:
X06.8
IN 4
Block select:
Coded position number
22 (bit 3)
24 V input
Optocoupler input.
Active with +24VDC (15...30V) with respect to X6.9.
Input current typically 13 mA.
IN4 is a high-speed input that may be used:
D as normal input
D for synchronizing the module to the external signal that can be applied to this input.
Assignment
g
Functionality
Servo function
Positioning function
High-speed input
Block select:
Coded position number
23 (bit 4)
Default setting:
X06.8
(IN 4)
X06.10/9
24 VIn, 0 VIn
74
ServoDyn D
1070066030 / 06
X21
SW+
SW
3
4
5
6
X21.1/2
SW+/SW
Setpoint input
Functionality
Servo function
Positioning function
Analog setpoint:
D 12-bit resolution for
DM.....33xx D
D 16-bit resolution for
DM.....4xxx D
not used
(setpoints are stored in the
positioning table)
1070066030 / 06
ServoDyn D
75
X22
X22.16
IN 5 IN 10
IN 5
IN 6
IN 7
IN 8
IN 9
IN10
24 V inputs
24 V inputs
Optocoupler inputs.
Active with +24 VDC (15...30V) with respect to X6.10.
Input current typically 13 mA.
Assignment
g
Functionality
Servo function
Positioning function
X22.1
(IN 5)
Block select:
Coded position number
24 (bit 5)
X22.2
(IN 6)
X22.3
(IN 7)
Mode selection:
20 (bit 1), cf. page 812
X22.4
(IN 8)
Mode selection:
21 (bit 2), cf. page 812
X22.5
(IN 9)
Reference cam
Default setting:
X22.6
(IN 10)
Home position
(cancels the traversing
movement, clears the distance to go and sets the
output signal X12.3, position
reached)
76
ServoDyn D
1070066030 / 06
7.1.2
Outputs
X12
Out 5
Out 6
Out 7
Out 8
Out 9
24 V outputs
7
8
X12.15
Out 5 Out 9
24 V outputs
Servo function
Positioning function
Standstill monitoring
n=0
X12.2
(Out 6)
Speed monitoring
n = nset
Axis active
X12.3
(Out 7)
In position
X12.4
(Out 8)
End of program/block
X12.5
(Out 9)
X12.1
(Out 5)
X12.6/7/8
Functionality
Out10
Functionality
Servo function
Positioning function
MC status message
For more information on the MC functions, please refer to the Application instructions on page 812.
1070066030 / 06
ServoDyn D
7.2
Programmable
inputs
Supply
inputs/outputs
Programmable
outputs
1
STA relay
2
3 FG
4 FG 0V
5 IN 1
6 IN 2
7 IN 3
8
9 24 VIn
10 0 VIn
1 Out 4
2 Out 3
3 Out 2
4
5
Out1 relay
6
X
0
5
X06
X34
X
0
6
X
3
4
X
5
5
.
.
.
.
.
.
.
..
.
.
.
.
..
.
RS 232 interface
X
9
9
Loop
RESET
X
7
1
In
X
7
2
Out
H1
FG
FGI
X71
X72
Personality module
X
2
7
H1
FG FGI
..
..
..
..
X
8
1
0
X
8
2
0
77
78
ServoDyn D
1070066030 / 06
DM
1
STA
2
X06
FG
FG 0V
IN 1
IN
2
IN 3
6
7
STA
relay
+24 V
24 V inputs,
programmable
8
9
10
X06.1/2
STA
24 VI
n 0 VIn
Supply
inputs/outputs
Status message
FG
External enable
Display via LED FG
1070066030 / 06
ServoDyn D
79
X06.5/6/7
IN 1, IN 2, IN 3
Programmable 24 V inputs
Optocoupler inputs.
Active with +24 V DC (16...30 V) with regard to X6.10.
Input current typically 17 mA.
Assignment:
D X6.5: Reference point switch
D X6.6: Limit switch, positive traverse direction
D X6.7: Limit switch, negative traverse direction
X06.9/10
24 VIn, 0 VIn
DM
X71
In
X72
Out
Optical
fibre
710
ServoDyn D
1070066030 / 06
7.3
X
0
5
CAN
CAN bus
Axis address
(hexadecimal)
Baudrate:
0 = 1000 kBaud
1 = 800 kBaud
2 = 500 kBaud
3 = 250 kBaud
4 = 125 kBaud
5 = 100 kBaud
6 = 50 kBaud
7 = 20 kBaud
8 = 10 kBaud
9 to F = 1000 kBaud
RS 232 interface
X
5
1
Mode:
2
S
3
S
4
S
5
Adr
X
9
9
Baud
Mode
RESET
0 = CAN open
1 = CAN rho
X06
X
0
6
H1
FG
FGI
X
3
4
.
.
.
.
.
.
.
..
.
.
.
.
..
.
X34
H1
FG FGI
..
..
..
..
X
8
1
0
X
8
2
0
1
2
3
4
5
6
7
8
9
10
STA relay
FG
FG 0V
IN 1
IN 2
IN 3
IN 4
24 VIn
0 VIn
1 Out 4
2 Out 3
3 Out 2
4
Out1
5
relay
6
Digital inputs
Supply
inputs/outputs
Digital outputs
1070066030 / 06
ServoDyn D
711
D
M
1
STA
2
X06
FG
FG 0V
IN 1
IN 2
6
7
8
9
10
X06.1/2
STA
STA
relay
+24 V
IN 3
IN 4
24 VIn
0 VIn
Supply
inputs/outputs
Status message
FG
External enable
Display via LED FG
712
ServoDyn D
1070066030 / 06
X06.5/6/7
IN 1, IN 2, IN 3
24 V inputs
Optocoupler inputs.
Active with +24 VDC (15...30 V) with regard to X6.10.
Input current typically 17 mA.
Assignment
Default setting:
X06.8
X06.5
(IN 1)
X06.6
(IN 2)
X06.7
(IN 3)
IN 4
24 V input
Optocoupler input.
Active with +24VDC (15...30V) with respect to X6.10.
Input current typically 13 mA.
IN4 is a high-speed input that may be used:
D as normal input
D for synchronizing the module to the external signal that can be applied to this input.
Assignment
Default setting:
X06.8
(IN 4)
X06.10/9
24 VIn, 0 VIn
High-speed input
1070066030 / 06
ServoDyn D
713
X51
1
Connection to be
made via external T
adapter, cf. CAN cable
CAN_L
CAN_GND
4
5
6
CAN_H
8
9
CAN cable
Both physical ends of the CAN cable must be equipped with a terminating resistor with typ. 120 W. The ready-made CAN cables from Bosch are
therefore different on the drive side:
D Through-way plug, black
(T adapter between the cable ends) and
D Terminating plug, green
(T adapter with terminating resistor)
The admissible length of the cable connecting the control unit and the
drives depends on the baudrate setting, part no. on request:
Baudrate
1000 kbits/s
25 m
800 kbits/s
50 m
100 m
T adapter black,
through-way plug
T adapter green,
terminating plug
rho3
rho4
or
CANopen
Cable length
depends on baudrate
Cable length
300 mm 5 mm
714
ServoDyn D
1070066030 / 06
Inverter
X51
X51
Inverter
X51
CAN bus1
CAN_Low
15
15
CAN_High
CAN_Low
CAN_GND
CAN bus2
CAN_Low
14
CAN_High
12
12
13
13
CAN_High
CAN cable for rho4 control or any other control unit with CANopen
rho4
X51, X52
rho4 or
CANopen
Inverter
X51
X51, X52
CAN_Low
CAN_GND
CAN_High
Inverter
X51
1
CAN_Low
CAN_GND
4
5
CAN_High
1070066030 / 06
ServoDyn D
715
Rexroth CAN connectors have been prepared for use with jumpers or
terminating resistors, so that the cables can be connected as shown
below.
CAN connectors at the drives
Terminating connector, green,
part no. 1070 919 030
9
4
CAN_GND
CAN_GND
CAN_Low
CAN_High
CAN_GND
CAN_High
CAN_Low
CAN_GND
CAN_GND
CAN_High
CAN_Low
CAN_GND
1
2
120R
ServoDyn D with CAN bus can be operated with the CANrho protocol or
the CANopen protocol. All CAN-specific settings are adjusted with rotary
switches S2...S5 on the front panel:
S2
S3
9...F
250
125
100
50
20
10
1000
Baudrate [kbits/s]
S4
1000
800
500
Mode
S5
CANopen CANrho
not used
CAN display
Green LED
Meaning
off
flashing
on
F = test
716
ServoDyn D
1070066030 / 06
7.4
X
0
5
PROFIBUS
PROFIBUS-DP
Axis address
(hexadecimal)
Mode:
0 = Normal operation
F = Test mode
S
2
FG
FGI
S
3
S
4
X
9
9
RESET
X
0
6
H1
RS-232 interface
X
5
1
X
3
4
.
.
.
.
.
.
.
..
.
.
.
.
..
.
X06
X34
H1
FG FGI
..
..
..
..
X
8
1
0
X
8
2
0
1
2
3
4
5
6
7
8
9
10
STA relay
FG
FG 0V
IN1
IN2
IN3
IN4
24VIn
0VIn
1 Out4
2 Out3
3 Out2
4
Out1
5
relay
6
Digital inputs
Supply
inputs/outputs
Digital outputs
1070066030 / 06
ServoDyn D
717
DM
1
STA
2
X06
FG
FG 0V
IN 1
IN 2
6
7
8
9
10
X06.1/2
STA
STA
relay
+24 V
IN 3
IN 4
24 VIn
0 VIn
Supply
inputs/outputs
Status message
FG
External enable
Display via LED FG
718
ServoDyn D
1070066030 / 06
X06.5/6/7
IN 1, IN 2, IN 3
24 V inputs
Optocoupler inputs.
Active with +24 VDC (15...30 V) with regard to X6.10.
Input current typically 17 mA.
Assignment
Default setting:
X06.8
X06.5
(IN 1)
X06.6
(IN 2)
X06.7
(IN 3)
IN 4
24 V input
Optocoupler input.
Active with +24VDC (15...30V) with respect to X6.10.
Input current typically 13 mA.
IN4 is a high-speed input that may be used:
D as normal input
D for synchronizing the module to the external signal that can be applied to this input.
Assignment
Default setting:
X06.8
(IN 4)
X06.10/9
24 VIn, 0 VIn
High-speed input
1070066030 / 06
ServoDyn D
719
X51
1
2
CNTR_P
DGND (C/C)
VP
Receive-Transmit-Data-P
Repeater control signal
Data reference potential 5 V
Supply voltage +5 V
DGND (C/C)
Receive-Transmit-Data-N
1...E
S2
S3
Mode
S4
Normal operation
Green LED
Meaning
off
PROFIBUS-DP is interrupted
on
not used
PROFIBUS-DP display
Test
720
ServoDyn D
1070066030 / 06
7.5
For measuring
purposes only
Analog
outputs
Power supply
Digital outputs
Dig. output
Dig. input
H1 H3
1
2
3
4
5
6
7
8
9
10
T1MOT
T2MOT
I1
I3
SW+
SW
I20mA
OUT1
OUT2
OUT0V
1
2
3
4
5
6
7
8
9
10
STA
relay
FG
FG 0V
PLA
PLB
PLC
DCB
24VIn
0VIn
1 fi < fx
2 fi = fs
3 n=0
4
FGI
5
relay
6
RS 232 interface
X23
X
2
3
X06
X34
X
0
6
X
3
4
X
1
3
X13
1
TEMP
relay
2
3 IGR
4 IRED
FG
FGI
.
.
.
.
.
.
.
..
.
.
.
.
.
.
.
.
..
.
.
.
.
..
.
.
.
.
.
X
9
9
RESET
Keyboard for
parameterization
R
H
1
H
2
TEMP
STA
H
3
FG FGI
..
..
..
..
X
8
1
0
X
8
2
0
1070066030 / 06
ServoDyn D
721
(Frequency inverter)
DM
1
STA
2
X06
FG
FG 0V
PLA
PLB
6
7
8
9
10
X06.1/2
STA
+24 V
STA
relay
PLC
DCB
24 VIn
0 VIn
Supply
inputs/outputs
Status message
FG
External enable
722
ServoDyn D
1070066030 / 06
CAUTION
A contactor in the motor lead must not be opened before the internal enable signal FGI has been switched off. Please use the FGI
contact for triggering this function (cf. page 727)
X6.5/6/7
X06.8
X6.6 (PLB)
X6.7 (PLC)
Active
parameter list
PL 1
PL 2
PL 3
PL4
PL5
PL 6
PL 7
PL8
1 = HIGH level,
= LOW level
DCB
X06.10/9
24 VIn, 0 VIn
1070066030 / 06
ServoDyn D
723
1
TEMP
X13
X13.1/2
TEMP
TEMP
+24 V
IGR
IRED
Temperature warning
IGR
IRED
Current reduction
724
ServoDyn D
1070066030 / 06
X23
T1MOT
T2MOT
I1
4
5
I3
SW+
SW
I 20mA
Out1
Out2
9
10
X23.1/2
T1MOT, T2MOT
Out 0V
Thermostatic
switch
not used
1
2
CAUTION
Malfunctions and destroyed inputs through unshielded connection leads!
Only use shielded cables and connect shield at both ends.
1070066030 / 06
ServoDyn D
725
X23.3/4
I1, I3
5
6
7
SW
+
SW
Input resistance 20 kW
0...20 mA setpoints
5
6
I 20 mA
+
I 20 mA
726
ServoDyn D
1070066030 / 06
X23.8/9/10
Output
(reference potential
X23.10)
via parameters
Setting ex works
X23.8 (Out1)
P40
X23.9 (Out2)
P39
Both outputs can be assigned the data AA0 ... AA9 listed in the following
table.
Level 0... +10 V, current and power signals can be adjusted (P41, P42).
Assignment
10 V ...
[ ] = Setting ex works
DM..4K
DM..8K
DM..15K
DM..30K
DM..30A
DM..45K
DM..45A
DM..140D
[A]
[ ]
[A]
[A]
[V]
[V]
[kVA]
[kW]
[%]
200 %
[_C]
100 _C
DM..85B
0.9...15
[9.5]
1.5...25
[15.9]
3.1...50
[31.8]
4.7...75
[47.7]
9.5...150
[95.4]
12.7...200
[127]
4.6...75
[75]
6.2...100
[100]
1000 V
Scaling with P42:
0.4...7.5
[7.5]
0.7...12.5
[12.5]
1.5...25
[25]
2.3...37.5
[37.5]
The following applies in general to the programming of the frequency inverter via the DSS-D:
Press Boot key prior to any parameter change (refer to page 720).
All values displayed at the drive in alpha-numerical format are
stored as purely numerical values in the DSS-D. When making
entries, you should therefore omit the letters, e.g. enter 7 in the
DSS instead of AA7 for the shaft output.
1070066030 / 06
ServoDyn D
727
X34
fi fx
fi = fs
n=0
24 V outputs
4
5
X34.1
fi t fx
fi = fs
n=0
Standstill monitoring
FGI
Internal enable
728
ServoDyn D
1070066030 / 06
DM control connections
7.6
X34
5
6
X34.1
Out 4
Holding brake
(option)
PE bar
0V
(X332)
K03
Direct control of
contactors up to 0.3 A
Out 4
U2
V2
W2
Inverter
In the case of contactors with a power input > 0.3 A an amplifier, e.g.
a relay, must be inserted to control the contactor.
1070066030 / 06
ServoDyn D
729
DM control connections
X34.2
Out 3
730
ServoDyn D
1070066030 / 06
DM control connections
Motor
M3
Connector
size
Motor connector SF(R)L0, L1, A2, A3
1
SF(R)A4...015/030
SF(R)B4.0091/0125...
SF(R)B5.0250...
SF(R)A4..060
U
SF(R)B4.0172/0230...
SF(R)A5
SF(R)B5.0460.20
Pin
1 (6-pin)
Pin
1.25 / 1.5
(8-pin)
0 V brake
24 V brake
(24 V 10%)
max. 0.3 A
0V
(X332)
Out3
U2
V2
W2
X68
Inverter
X69
DM..K:
Point-to-point terminal
from brake supply filter
In the case of contactors with a power input > 0.3 A an amplifier, e.g.
a relay, must be inserted to control the contactor.
1070066030 / 06
ServoDyn D
731
DM control connections
Connection with MBC (brake connection with relay and protective circuitry)
Motor
M3
A1 A2 13 14
X78
0 V brake
0V
24 V brake
(24 V 10%)
24 V
Out3
U2
V2
W2
X40
X40
0V
24 V
MBC
DM..K
X34.3
Out 2
Temperature warning
Out 1
Relay contact
Interface
Analog interface
SERCOS
interface
Other types
Default setting:
X34.4/5
(n.o.c.)
732
ServoDyn D
1070066030 / 06
DM control connections
7.7
DMW
8
7
6
5
X76
P (24 VPWR)
FGP
FGN
N (0 VPWR)
4
3
2
Feedback
Safety relay
of the output stage
X76.1/2
Normally-closed contact
Normally-open contact
0 VPWR
FGN/FGP
1070066030 / 06
ServoDyn D
733
DM control connections
X76.8
24 VPWR
7.8
Module cross-connections
734
ServoDyn D
1070066030 / 06
DM control connections
7.9
Transmission rate:
9600 bits/s
Parameters:
even parity, 8 data bits, 2 stop bits
Handshake:
Software handshake (XON, XOFF)
Inverter
PC
X99
max. length:
15 m
RX
TX
COM1 or COM2
RX
TX
GND
GND
6
7
8
9
Shield continuity
through metal housing
of the plug connection
RX
Receive Data
TX Transmit data, data transmission to DSS
GND signal ground
1070066030 / 06
ServoDyn D
735
DM control connections
7.9.1
Encoder cables
We recommend using prefabricated Bosch encoder cables for the SF
and SR servo motors. Depending on the individual case, these cables
are available as
D Standard cable
D Highly flexible cable
D UL-conformant cable
UL encoder cables have to be used for UL/CSA-certified drive inverters in order to ensure that the entire system meets the UL/CSA
requirements.
CAUTION
Damage to cables due to inadmissible movements.
Please note the technical data of the cables specified in the Configuration manual, part no. on page 17.
736
ServoDyn D
1070066030 / 06
DM control connections
Prefabricated encoder cables, shielded
No of
cores
Cable
17 cores
SF, DU
Encoder system
ECN (single-turn)
EQN (multi-turn)
SR,
Resolver,
other types gear encoder
Standard
Highly flexible
Part no.
(5 m length)*
Part no.
(5 m length)*
0.14
SF
ECN (single-turn)
EQN (multi-turn)
UL-conformant 17 cores
cable
0.16
SF, DU
ECN (single-turn)
EQN (multi-turn)
on request
on request
SR,
Resolver,
other types gear encoder
* Part no. of cable lengths 7, 10, 12, 15, 20, 25, 35, 50, 100 m on request
5.5
Mounting hole
Gasket
40
Sealing ring
26.5
Clamp
Flange
Housing/Cabinet
1070066030 / 06
ServoDyn D
737
DM control connections
Socket X5,
26-pin
Flange socket
17-pin
BN
0.14
or
GN
0.14
blu
RD
0.14
whi
Inner shield T
Inner shield A
11
UA+
GN
0.14
15
gn/blk
YE
0.14
UA+
16
yel/blk
UA
UA
GND
22
UB+
23
BU
0.14
12
UB
24
RD
0.14
13
GY
0.14
WH
0.14
Inner shield B
+5V
red/blk
10
BU
18
BNBU 0.5
0.14
19
GY
26
BNRD 0.5
0.14
13
UB+
UB
Inner shield R
0V
blu/blk
4
10
whi
whi/gn
blu
brn/gn
0V-sensor
0V
5V-sensor
+5V
14
Inner shields A, B, R to
be connected with insulation to outer shield.
15
16
17
11
GY
0.14
14
grey
PK
0.14
Data
12
17
pink
VT
0.14
Data_N
20
vio
YE
0.14
Timing
21
yel
Timing_N
25
Outer shield
The outlined pin assignment only applies to cables and motor encoders supplied by Rexroth.
738
ServoDyn D
1070066030 / 06
DM control connections
Pin assignment for encoder cable for gear encoder and resolver
Socket X5,
26-pin
DM
Motor types SR
BN
0.14
or
GN
0.14
blu
whi
RD
0.14
Inner shield T
X1
Inner shield A
X2
S1
GN
0.14
15
S3
YE
0.14
A+ S1
16
Inner shield B
22
S3
23
BU
0.14
12
RD
0.14
B+ S2
S4
24
13
R1
GY
0.14
11
WH
0.14
R+ R1
R3
R R3
GND
BU
18
BNBU 0.5
19
GY
26
BNRD 0.5
14
0.14
0.14
4
10
1
7
0V-sensor
0V
5V-sensor
+5V
Inner shields A, B, R to
be connected with insulation to outer shield.
15
16
17
PK
0.14
17
11
GY
0.14
14
12
13
20
VT
0.14
21
YE
0.14
Resolver
+5V
10
S4
0V
Inner shield R
Gear encoder
S2
25
Outer shield
The outlined pin assignment only applies to cables and motor encoders supplied by Rexroth
1070066030 / 06
ServoDyn D
739
DM control connections
7.10
Encoder switch
Encoder simulation
Signal level
Driver to RS 422
UHigh 2.5 V where IHigh = 20 mA
ULow 0.5 V where ILow = 20 mA
Maximum load
IHigh 20 mA
ILow 20 mA
Operating times
Rise time
Fall time
Voltage supply
5 V 5%
Power input
50 mA without load
100 ns
(programmable with DSS-D, depends on output
frequency)
Output frequency
1 MHz
(programmable with DSS-D, depends on line
number and max. motor speed)
Line number
16 383
(programmable with DSS-D, depends on max.
motor speed)
t+ 100 ns
t 100 ns
360_ el.
UA1
a
UA2
90_ el.
UA0
740
ServoDyn D
1070066030 / 06
DM control connections
Control
Cable, 14-wire
Socket X81
UA1
UA1
UA2
UA2
+5V-sensor
UA0
UA0
UAS
UAS
+5V
+5V
0V-sensor
10
10
0V-sensor
UA1
UA1
UA2
UA2
+5V-sensor
UA0
UA0
11
0V
12
12
0V
13
14
15
max. 50 m
1070066030 / 06
ServoDyn D
741
DM control connections
7.11
CAUTION
Damages at the inverter or measuring system by inserting or removing plug-in connections on live systems!
Switch the drive off beforehand!
742
ServoDyn D
1070066030 / 06
DM control connections
OM 01
+5 V +1%/5%
300 mA
5-times interpolation
D Pulse multiplication:
50 kHz
D Pin assignment:
Signal diagram
360el.
Ie1
90el
.
Ie2
Ie0
1070066030 / 06
ServoDyn D
743
DM control connections
The cable shield must have a continuous connection from the front panel
of the option module to the measuring system.
Pin assignment OM 01 for measuring systems with sinusoidal current signals
Inverter
Socket X55,
15-pin
green
yellow
blue
red
0.14
0.14
0.14
0.14
grey
pink
0.14
0.14
brown 1.0
10
10
12
12
Ie1+
Ie1
Ie2+
Ie2
Ie0+
Ie0
+5V
Shield
0V
Cable, 8-wire
(3 x (2 x 0.14 mm2)
+ 2 x 1.0 mm2)
Coupling,
9-pin
Measuring
system
1
2
5
6
7
8
+5V
white 1.0
0V
Shield continuity
through metal housing
of the plug connection
max. 20 m
Metal connector covers must be used for the 9-pin coupling (Heidenhain-ID-No. 228 562 01 or 237 525 04) on the measuring system
side and the 15-pin sub-D connector on the option module! Cable
shielding must have large-surface contact with the strain-relief
clamp!
For prefabricated cables, refer to page 111.
744
ServoDyn D
1070066030 / 06
DM control connections
OM 02
D Power supply:
+5 V 3 %,
regulated via sensor leads
300 mA
D Pulse multiplication:
1 MHz
150 ns
100 ns
b) Evaluation of UAS
D Pin assignment
Signal diagram
Measuring direction:
a
positive
negative
A/Ua1
A/Ua1
B/Ua2
B/Ua2
R/Ua0
R/Ua0
c
b a
positive
b
1070066030 / 06
ServoDyn D
745
DM control connections
Cable, 14-wire
(10 x 0.14 mm2
+ 4 x 0.5 mm2)
Coupling,
15-pin
1
white/yellow 0.14
green 0.14
grey 0.14
pink 0.14
+5V-sensor
brown 0.5
UA0
white 0.14
UA0
white/grey 0.14
UAS
violet 0.14
+5V
red
0.5
0V-sensor
10
10
black 0.5
10
12
12
blue
12
UA1
UA2
UA2
UA1
0V
0.5
Shield continuity
through metal housing
of the plug connection
max. 50 m
2
3
4
Measuring
system
UA1
UA1
UA2
UA2
+5V-sensor
UA0
UA0
UAS
+5V
0V-sensor
0V
746
ServoDyn D
1070066030 / 06
DM control connections
white/yellow 0.14
green 0.14
grey 0.14
UA1
UA2
UA2
+5V-sensor
UA0
UA0
UAS
violet 0.14
+5V
red
0.5
0V-sensor
10
10
black 0.5
10
12
12
blue
12
UA1
0V
1
2
3
pink 0.14
brown 0.5
white 0.14
white/grey 0.14
Measuring
system
EXE
Cable, 14-wire
(10 x 0.14 mm2
+ 4 x 0.5 mm2)
6
7
UA1
UA1
UA2
Ie1+
Ie1
Ie2+
Ie2
UA2
+5V-sensor
Ie0+
UA0
Ie0
UA0
0.5
Shield continuity
through metal housing
of the plug connection
max. 50 m
UAS
+5V
+5V
0V-sensor
Shield
0V
0V
+5V
0V
1070066030 / 06
ServoDyn D
747
DM control connections
OM 03
UA
90el.
UB
UR
The external cable shield must have a continuous connection from the
front panel of the option module to the measuring system.
The inner cable shields A, B and R must be connected with insulation to
the outer shield.
748
ServoDyn D
1070066030 / 06
DM control connections
Socket X55
26-pin
Plug connection
17-pin
BN
0.14
GN
0.14
RD
0.14
Inner shield T
4
Inner shield A
11
UA+
GN
0.14
15
gn/blk
UA
YE
0.14
16
yel/blk
GND
22
UB+
23
BU
0.14
12
blu/blk
UB
24
RD
0.14
13
red/blk
GY
0.14
WH
0.14
whi
0V-sensor
whi/gn
0V
blu
5V-sensor
brn/gn
9
7
0V
+5V
Inner shield B
BU
18
BNBU 0.5
19
GY
26
BNRD 0.5
0.14
0.14
13
15
16
UA
UB+
UB
Inner shield R
10
14
UA+
10
+5V
Inner shields A, B, R to
be connected with insulation to outer shield.
17
11
GY
0.14
14
grey
PK
0.14
Data
12
17
pink
Data
20
VT
0.14
vio
YE
0.14
Timing
21
yel
Timing
25
Outer shield
typ. 1 m
1070066030 / 06
ServoDyn D
DM control connections
Pin assignment OM 03 for measuring systems without interface or with I2C interface
Socket X55
26-pin
Plug connection
17-pin
BN
0.14
GN
0.14
RD
0.14
Inner shield T
Inner shield A
S1
GN
0.14
15
S3
YE
0.14
16
22
23
BU
0.14
12
S4
24
RD
0.14
13
R1
GY
0.14
11
R3
WH
0.14
GND
+5V
BU
18
BNBU 0.5
19
GY
26
BNRD 0.5
15
16
UA
UB+
UB
UR+
UR
Inner shield R
10
14
UA+
Inner shield B
S2
0V
0.14
0.14
5V-sensor
+5V
17
PK
0.14
17
11
GY
0.14
14
20
VT
0.14
21
YE
0.14
12
13
Outer shield
0V
Inner shields A, B, R to
be connected with insulation to outer shield.
25
0V-sensor
10
I2 C
Data
Timing
Timing
typ. 1m
OM 03
optionally for
I2C interface
749
750
ServoDyn D
1070066030 / 06
DM control connections
7.12
X13
X13.14
Out1
Out2
Out3
3
5
Out4
GND
GND
Digital
testing outputs
OM 04
1
A_Out1
GND
3
4
A_Out2
GND
A_Out3
GND
A_Out4
GND
X14
Analog outputs,
programmable
1070066030 / 06
ServoDyn D
751
DM control connections
X14.14
Analog interface,
SERCOS interface
CAN bus
PROFIBUS-DP
Positioning
function (MC)
VMA..KR,
VMA..B,C,D
VMW..F
X14.1/2
(A_Out1)
Speed setpoint
S-0-0036
X14.3/4
(A_Out2)
Actual speed
S-0-0040
X14.5/6
(A_Out3)
Torque setpoint
S-0-0080
X12.7/8
(A_Out4)
752
DM control connections
Notes:
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
81
Application instructions
Application instructions
8.1
8.1.1
24 V hardware signals:
D Drive On AE (X06.7 on the VM...B,C,D,F supply module only)
switches on the drive assembly power on the supply module.
D Enable external FG (X06.3 on the DM)
Hardware enable for each axis:
D Without the FG signal the motor torque is zero and the motor
comes to a stop without setpoint control.
D Braking is effected by means of a plug braking module or
by using a holding brake integrated into the motor.
82
ServoDyn D
1070066030 / 06
Application instructions
FG (DM,
X06.3)
0V
1
Drive on
(software enable)
0
1
KSB (DM,
X34.1)
FGI
0
24 V
0V
(inhibited)
Torque
yes
no
Holding brake
(DM, X34.2)
Speed
24 V
0V
nset
n=0
n=0
24 V
0V
P-0-0505
S-0-0206
S-0-0207
D FG
D Drive on
off:
off:
D Drive enable
off:
S-0-0138
or
S-0-0260
or
P-0-0260
1070066030 / 06
ServoDyn D
83
Application instructions
Sequence diagram with SERCOS interface: Cycle off / on upon entering a protective zone
DANGER
Do not use for suspended axes!
24 V
NH / NH1
0V
nset
Speed
n=
0
Mains voltage
400 V
0V
Enable signal FG
24 V
0V
yes
FGI/Torque
no
Holding brake
Holding brake
response time
24 V
0V
(inhibited)
Braking time
P-0-0505
S-0-0206
Delay
Drive On
Cycle off
The FG enable signal must remain active during the braking time via a
time relay before the mains voltage and FG are switched off, otherwise,
the holding brake will engage immediately.
Cycle on:
The mains voltage and FG are connected simultaneously. In order to
avoid a VM error which may occur because the DC link is no longer fully
charged, there must be a delay before activating the internal enable signal. This is done with the help of parameter P-0-0505 (KSB (plug braking) enable delay).
The internal enable signal (FGI) applies a torque to the motor and releases the holding brake. The response time of the holding brake is typically 80 ms with the relay connected in series. No traversing command
may be carried out during this time. For this purpose, parameter
S-0-0206 (Waiting time drive on) is set (typically 100 ms).
84
ServoDyn D
1070066030 / 06
Application instructions
8.1.2
EMERGENCY-STOP
Time
[sec]
10 11 12 13 14 15
(0 = not permissible)
= Default Setting
The control remains active during the tripping delay. The supply
module then cuts the power off and the drives come to a stop without setpoint control.
The chosen time setting must be as short as possible.
DANGER
In the event of a supply module failure, the motors have no torque
and come to a stop without setpoint control!
Activate plug braking or an integrated holding brake in this case.
1070066030 / 06
ServoDyn D
85
Application instructions
24 V
NH / NH1
0V
1
Status word,
bit 14
0
1
Status word,
bit 15
Holding brake
24 V
0V
(inhibited)
Plug braking
module
FGI/Torque
24 V
0V
yes
no
Speed
nset
n=0
VM supply
module power
on
off
S-0-0138
or
S-0-0260
or
P-0-0260
All drives to n = 0,
max. time is that set by S1
86
ServoDyn D
1070066030 / 06
Application instructions
8.2
24 V hardware signals:
D Drive On AE (X06.7 on the VM...B,C,D supply module only)
switches on the drive assembly power on the supply module.
D Enable external FG (X06.3 on the DM)
Hardware/software enable for each axis:
When FG is switched off, the motor is braked as specified in
P-0-0125.
Sequence diagram
FG (DM, X06.3)
24 V
0V
1
0
yes
no
Holding brake
(DM, X34.2)
Speed
24 V
(Holding brake
response
time)
0V
nset
n=0
n=0
24 V
0V
P-0-0505
S-0-0206
(Holding brake
response time)
P-0-0004
S-0-0207
P-0-0590
1070066030 / 06
ServoDyn D
87
Application instructions
8.3
Complete failure
DANGER
In the event of a power failure on a supply module with current regeneration, the motors have no torque and come to a stop without
setpoint control!
Dangers can be avoided by taking one of the following measures:
In the event of a power failure or Main switch off, the supply module detects undervoltage, output Out3 on the X34.2 terminal strip changes to
0 V.
L
88
ServoDyn D
1070066030 / 06
Application instructions
Sequence diagram with SERCOS interface: Voltage failure with UPS and EBX
Mains voltage
400 V
0 V
24 V
24 Vpower supply
0 V
1
NH / NH1
0
Speed
nset
n=0
Holding brake
24 V
0V
(inhibited)
FGI/Torque
ja
nein
Enable signal FG
24 V
0 V
Braking time
Response
time of VM
(10 ms)
Short-time failure
In the event of a 1-phase mains failure, the VM continues to operate,
however, at a reduced power of 66%. Frequent 1-phase short-time failures can thus be bridged by the VM.
A long 1-phase failure my result in a VM overload. If Drive halt is to be
performed in this case, output Out4 on terminal strip X34.1 must be
looped into the EMERGENCY-STOP circuit or evaluated by the PLC.
Once the Drive halt function has been initiated, it will be completed
even though the mains voltage should return in the meantime.
When the mains power returns and Drive on is active, the DC link control will be resumed.
1070066030 / 06
ServoDyn D
89
Application instructions
8.4
Function chart
MTG
DM
Motor
encoder
(X05)
Encoder
simulation
(X81)
24 V
24 V
MT
G
DM
Motor
encoder
(X05)
Encoder
simulation
(X81)
STA
(X06.1/2)
STA
(X06.1/2)
Out1
(X34.4/5)
Out1
(X34.4/5)
IN 2 (X06.6)
Control
Encoder
interface
Ready
Complete
Start
IN 2 (X06.6)
810
ServoDyn D
1070066030 / 06
Application instructions
STA
Status
24 V
0V
IN 2
Start
24 V
0V
Out1
Complete 24 V
0V
FG
External
enable
24 V
0V
Counter start-up to
absolute position
Operation with
setpoint
If the status relay is switched off due to an error when the counter
has started up, transmission of the absolute value is no longer affected. Out1 remains high, transmission does not have to be restarted.
1070066030 / 06
ServoDyn D
Application instructions
STA contact
closed ?
No
Yes
Out 1 = 0 ?
No
Yes
Starting edge IN2
Transmission
completed?
Yes
Activate position
controller
Activate software limit
switches
No
811
812
ServoDyn D
1070066030 / 06
Application instructions
8.5
IN 8
IN 7
Automatic
Referencing
Jog
Jog +
Jogging
gg g
8.5.1
Jogging mode
In jogging mode, the drive can be traversed manually without referencing and without processing certain blocks.
1070066030 / 06
ServoDyn D
813
Application instructions
8.5.2
Referencing
For automatic operation, the axis must have been referenced.
The output signal Axis has been referenced is cleared when referencing is started, and set when referencing has been properly completed.
D Referencing direction according to S-0-0147, bit 0
D Referencing speed according to S-0-0041
D Referencing acceleration according to S-0-0042
defined internal zero pulse
Referencing movement
in referencing direction
referencing direction
reference cam
Referencing movement
when axis has reached the cam
opposite referencing
direction
reference cam
Signal behavior
(IN 7)
Referencing
mode
on
off
(IN 8) on
off
Start/Stop
(IN 6)
24V
0V
24V
Axis has been
referenced (Out 5)
0V
814
ServoDyn D
1070066030 / 06
Application instructions
8.5.3
Automatic mode
In automatic mode, the user program is processed in the form of a position table. The position table can be created with the help of the MC user
interface. It is automatically stored in the drive (example):
Block
no.
Position
Speed
absolute / incremental
[mm]
[mm/sec]
Acceleration
[mm/sec2]
Deceleration
[mm/sec2]
145a
1000
2000
2000
20i
500
20
2000
.... etc.,
max. 32 blocks (= positions)
With absolute position data, the target position is indicated, with incremental position data, the axis performs a relative movement by the
specified value.
Examples of the syntax of position 100:
absolute:
100
100a
100abs
incremental: 100i
100 ... i
100incremental
Signal behavior
In automatic mode, the Start/Stop command initiates processing of the
table set selected at inputs IN 1 IN 5. Each block is released again, so
that any block order can be selected.
1070066030 / 06
ServoDyn D
Application instructions
24V
Axis has been
referenced (Out 5)
0V
(IN 7)
on
off
Mode
=Automatic
(IN 8) on
off
Start/Stop
(IN 6)
24V
End of program/block
(Out 8)
24V
Axis active
(Out 6)
24V
In position
(Out 7)
24V
Speed
nset
0V
0V
0V
0V
n=0
Process
block 1
Block
end/
transition
815
816
Application instructions
Notes:
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
91
Personality module
Personality module
The personality module is used in:
D supply modules VM with current regeneration
D three-phase modules DM with SERCOS interface.
CAUTION
Damages possible by improper handling!
The Personality Module must not be inserted or removed unless
the drive is switched off.
FEPROM
This plug-in board for the computer motherboard contains the FEPROM
memory for the operating software and parameters and the dip switches
for the basic setting for the SERCOS interface.
The personality module determines the drive inverters behavior and
can take control of the drive characteristics following a module exchange
when simply plugged into the new module.
No function in VM
DIP switch on PM..A
on
on
off
off
ML T B D
7 6 5 4 3 2 1 0 Address
92
ServoDyn D
1070066030 / 06
Personality module
Function
Select master function:
SERCOS interface is master
DSS-D is master
M
on
off
(default)
L
on
off
T
on
off
B
(default)
on
off
D
(default)
on
off
on
0
1
off
Significance
27
26
25
24
23
22
21
20
Example address:
1070066030 / 06
ServoDyn D
Personality module
Function
M
on
Not used.
off
L
on
Not used.
off
T
on
off
B
on
off
7-segment display:
Display VM software release
Display VM operating status
D
on
off
(default)
Not used.
93
94
Personality module
Notes:
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
101
Dimensioned drawings
10
Dimensioned drawings
10.1
10.5
R 3.25
NV
VMA..KB(E)
115
99
50
R2
75
DM 45K
2 x DM..K
49
49
74
50
50
50
50
25
50
50
50
50
25
25
50
75
445
430
R 7.5
The distance between the line wiring module NV and the supply
module must be 25 mm when installing the units.
Otherwise, the mains filter in the line wiring module will heat up too
much if the supply module is continuously operated at nominal
load, resulting in reduced performance data.
102
ServoDyn D
1070066030 / 06
Dimensioned drawings
10.1.1
NE 21/B
NAA 21
115
10.5
R 3.25
R2
50
VMA 21KR
115
100
2 x DM..K
99
49
50
50
50
50
50
50
50
50
49
50
74
50
25
50
25
25
50
100
50
445
430
R 7.5
The distance between line reactor NE 21/B and the mains connection module NAA must be 25 mm when installing the units.
Otherwise, the mains filter in the mains connection module will
heat up too much if the line reactor is continuously operated at
nominal load, resulting in reduced performance data.
1070066030 / 06
ServoDyn D
Dimensioned drawings
10.2
R 3.25
R 7.5
50
NA
RM../VM
50
49 49
445
430
RM../DM
486
7.5
NAA: 521.5
RM: 522.5
48
Top mounting
115
50
A
50
Bottom mounting
10.5
R2
A
50
50
50 50
Module
type
Dimensions [mm]
RM B/VM
RM C/VM
RM D/VM
50
100
150
100
150
200
RM A/DM
RM B/DM
RM D/DM
50
150
50
100
200
103
104
ServoDyn D
1070066030 / 06
Dimensioned drawings
10.3
VMA..B,C,D
DMA..B
DMA..A
1 mm in assembled state
0.5
B
199
99
49
100
504
521.5
115
DMA..D
63
Pivot
point
Module
type
Dim. B
[mm]
VMA 35B
VMA 70C
VMA 90D
99
149
199
min. clearance
min.
dismounting height
Hanging on the
inverter module
min.
dismounting depth
288
100
100
min. clearance
250
18.5
R 7.5
24.5
199
150
50
R2
299
250
Supply module
VMW 180F
50
299
250
Three-phase module
DMW 290F
10.4
287
10.5
R 3.25
1070066030 / 06
ServoDyn D
Electric Drives Bosch Rexroth AG
and Controls
Dimensioned drawings
21.6
489
550
566
51
7.5
87.6
105
106
ServoDyn D
430
451.8
15
24.5
50
34.5
135
115
445
NE 21/B
400.9
10.5.1
(17.7)
Line reactors NE
7.5
10.5
(26.4)
Dimensioned drawings
1070066030 / 06
1070066030 / 06
ServoDyn D
Dimensioned drawings
NE 21/C
50
20
24.5
445
400
430
450.9
34.65
102
(26.4)
100
7.5
20.5
66.2
60.6
195
(18.6)
10.5.2
92.5
125
107
108
ServoDyn D
1070066030 / 06
Dimensioned drawings
10.5.3
n1
n2
4 x oblong hole C
Type
a
[mm]
b
[mm]
h
[mm]
n2
[mm]
n1
[mm]
C
[mm]
Mass
[kg]
NE 35/A
215
115
220
180
80
9 x 11
15
NE 70/A(A1)
242
135
250
190
115
10 x 17
23
NE 100/A
310
165
280
240
134
10 x 18
47
1070066030 / 06
ServoDyn D
Dimensioned drawings
10.5.4
NE 180/A
200020
U12
(V12)
(W12)
U21
(V21)
(W21)
U22
(V22)
(W22)
280
U11
(V11)
(W11)
Terminal UK16
with end supportU3
(W3)
ing(V3)
plate
47
50
PE connection M12
2250.5
1870.5
2600.5
2300.5
20
175
112.5
Rating plate
(SMP/7701.52/SS/JJ
400uH/180A/8KHz/38kg
1070921520)
25
15
20
40
140
Weight: approx. 39 kg
109
ServoDyn D
1070066030 / 06
Dimensioned drawings
Filter capacitor
250
30.5
60
22
10.6
123.3
121
PE connection M6
1070066030 / 06
ServoDyn D
1011
Dimensioned drawings
10.7
Mains filter
a
h
d
a1
c1
c2
e2
n2
PE L3 L2 L1
Load
Line
PE L3 L2 L1
b1
n
n1
e1
16
25
36
50
80
120
150
180
918 475
918 476
918 477
918 478
918 479
919 011
920 600
920 599
Dimensions
a [mm]
163 max.
216 max.
300 max.
348 max.
404 max.
a1 [mm]
141 max.
166 max.
221 max.
261 max.
301 max.
b [mm]
113 max.
156 max.
171 max.
b1 [mm]
86 max.
126 max.
141 max.
h [mm]
81 max.
91 max.
141 max.
n [mm]
82.5 0.2
n1 [mm]
70 0.2
80 0.2
115 0.2
n2 [mm]
100 0.3
140 0.3
155 0.3
s [mm]
5.5 0.1
6.6 0.2
6,6 0.2
c1 [mm]
20.5 0.5
31 0.5
c2 [mm]
41 max.
48 0.5
54 0.5
74 0.5
d [mm]
36 1
46 1
90 1
97 1
105 1
e1 [mm]
25 1
30 1
62 0.8
65 0.8
62 0.8
e2 [mm]
12.5 1
22.5 1
4 mm2
10 mm2
Terminal connector
l
[mm] (ground)
22.5 1, M6
18 0,5
25 mm2
50 mm2
32 1, M10
16 0.5
95 mm2
ServoDyn D
1070066030 / 06
Dimensioned drawings
a1
c1
c2
e3
n2
n3
n2
Load
Line
b1
n
n1
l
e1
Limit class A,
UL recognized
36
1070 920 963
Dimensions
a [mm]
215 max.
a1 [mm]
166 max.
b [mm]
115 1
b1 [mm]
122 max.
h [mm]
86 max.
n [mm]
80 0.2
n1 [mm]
115 0.2
n2 [mm]
140 0.3
n3 [mm]
135 0.3
s [mm]
6.6 0.2
c2 [mm]
41 max.
d [mm]
40 1
e1 [mm]
18 1
e3 [mm]
39 0.3
Terminal connector
10 mm2
[mm] (ground)
M6
Connection bolt M8
ServoDyn D
Inscription
1070066030 / 06
Electric Drives Bosch Rexroth AG
and Controls
Dimensioned drawings
LINE
LOAD
1013
ServoDyn D
1070066030 / 06
Dimensioned drawings
10.8
Part no.
1070
1070
1070
1070
1070
913 544 913 545 913 546 913 547 914 767
1070
913 862
Rx (10%)
8R2
57 Ws
1R
4085 Ws
3R3
293 Ws
Dimension A
Dimension B
5R6
261 Ws
3R3
785 Ws
1R
785 Ws
110 mm
126 mm
95 mm
163 mm
Circuit diagram
42
35
Rx
58
tie-bar
Rx
PE
515
92
10 OHM
MADE IN GERMANY
123
10.9
Rx
2.5mm
100
542
600
5.5
64
1070066030 / 06
ServoDyn D
111
Part numbers
11
Part numbers
11.1
Accessories
Designation
Line reactor NE
Part no.
NE 21/B (module-type
construction)
UL-recognized
NE 35/A
NE 35/A, UL-recognized
NE 70/A
NE 70/A, UL-recognized
NE 70/A1
NE 180/A
Filter capacitor
for NE 180
16 A, UL-recognized
25 A, UL-recognized
36 A, UL-recognized
50 A, UL-recognized
80 A, UL-recognized
120 A, UL-recognized
150 A, UL-recognized
180 A, UL-recognized
36 A reinforced,
UL-recognized
80 A, reinforced
36 A special filter
65 A special filter
on request
EBX 460 D
Cables, made-tomeasure
Encoder cable
Power cable
Encoder simulation, 14-wire
112
ServoDyn D
1070066030 / 06
Part numbers
Designation
Part no.
DM..K
DM..A,B,D,F (1.5 6 mm2)
DM..A,B,D,F (10 16 mm2)
Cable bushing
(metal flange)
Encoder cable
Power cable
DC link connection:
(compact mechanics)
right-side connection
left-side connection
(backplane modules)
right-side connection
left-side connection
1070066030 / 06
ServoDyn D
113
Part numbers
11.2
Options
Designation
Option modules
direct measuring
system:
Option module
analog outputs:
Cable, made-tomeasure
Mating connector
11.3
Part no.
OM 01 D
OM 02 D
OM 03 D
OM 03 D (125 kHz, preferred option)
OM 04 D
OM 01 and OM 02
OM 03
11.4
Part no.
Spare fuses
Designation
Part no.
Fuse for
24 V power supply
VM (20 A/32 V)
114
Part numbers
Notes:
ServoDyn D
1070066030 / 06
1070066030 / 06
ServoDyn D
Appendix
Appendix
A.1
Index
Numbers
24 V load power supply unit, 23
Current input of the modules, 518
24 V supply, 517
7segment display DM. See Manual Diagnostics
ServodynD
7segment display VM
d.c. link voltage, 616
Excess temperature, 613
Mains failure, 612
Normal operating mode, 610
Overload, 612
A
Absolute encoder position, Transmission via X81, 89
Ambient air, 24
Autotransformer, 56
B
Backplane modules
Dimensions, 103
Function, 21
Brake connection
Brake supply filter with/without pointtopoint terminal, 526
with relay and protective circuitry, 527
C
Cable bushing
Encoder cable, 736
Power connection to the motor, 519
Cables, Direct measuring system, 113
CAN bus
Baudrate, 715
Connection, 713
LED display, 715
CAN connectors, 715
Cold module installation, 37
Combination of both mechanics, Dimensions, 103
Connection overview, 41
Connection X05, 735
Connection X51, 713, 719
Connections overview
Analog interface, 71
CAN bus, 710
DM..8001 (ASM), 720
Positioning function (MC), 71
PROFIBUSDP, 716
SERCOS interface, 77
VMA..B,C,D supply modules, 68
VMA..K supply modules, 61
VMA..KR supply modules, 68
VMW..F supply modules, 68
Cooling water, Technical data, 36
Current reduction, 723
Cycle off / on upon entering a protective zone, Sequence diagram with SERCOS interface, 83
Cycle on / off, Sequence diagram with SERCOS interface, 82
D
DSub connector
CAN bus, 713
Direct measuring system, 741
Encoder switch/encoder simulation, 740
Motor encoder, 735
OM 01, 743
OM 02, 745
OM 02 for pulseshape electronics (EXE), 746
OM 03 for measuring systems with EnDat interface, 748
OM 03 for measuring systems with I2C interface,
749
PROFIBUSDP, 719
RS 232, 734
DC link, 616
DC link connection, 311
Combining different mechanics, 311
Compact mechanics without backplane modules,
38
Tworow module arrangement, 314
VMW..F and DMW..F, 310
with backplane modules, 39
DC link test sockets, 616
Dead mans key, VMA..K, 62
A1
A2
ServoDyn D
1070066030 / 06
Appendix
Dimensions
Backplane modules, 33
Combination of both mechanics, 103
DM..K, 101, 102
DMA..A,B,D, 104
DMW..F, 105
DMW..F (water cooling), 34
Filter capacitor, 1010
Line reactor NE, 106
Mains connection module NAA 21, 102
Mains filter, 1011
Mains filter, reinforced, 1012
NAA 35...90, 103
NV21, 101
Plug braking modules, 1014
RM, 103
Special filters, 1013
VMA 21KR, 102
VMA..B,C,D, 104
VMA..K, 31, 32
VMA..KB, VMA..KE, 101
VMW..F, 105
Direct current brake, 722
Direct measuring system, 741
absolute, with EnDat interface, 747
with sinusoidal current signals , 742
with sinusoidal voltage signals, 747
with squarewave signals, 744
Documentation, 17
Drive components, 21
Layout, 25
Drive On, 610, 81, 86
Drive operation signals
Drive enable (software), 81
Drive hold (software), 81
Drive On (hardware), 81, 86
Drive on (software), 81
Enable FG (hardware), 81, 86
E
Earthleakage circuitbreaker, 54
Earthing, 51
24 V power supply unit, 53
Connection between the modules, 315
Protective earthing of inverters, 51
Protective earthing of motors, 52
Electrical connection, Block diagram, 41
EMC, 53
EMC Directive, 11
EMC product standard, 11
EMERGENCYSTOP
Behavior with SERCOS interface, 84
Sequence diagram with SERCOS interface, 85
Tripping delay, 84
VM..B,C,D,F, channel 1, 614
VM..B,C,D,F, channel 2, 610
VMA..K, 62
EMERGENCYSTOP devices, 15
EMERGENCYSTOP switchgear
Connection to VMA..KB, VMA..KE with other interfaces, 66
Connection to VMA..KB, VMA..KE with SERCOS
interface, 67
Connection to VMA..KR, VM..B,C,D,F, 617
Encoder cable
Pin assignment gear encoder, 738
Pin assignment resolver, 738
Pin assignment STG/MTG, 737
Encoder simulation
Pin assignment, 740
Technical data, 739
Transmission of the absolute encoder position,
89
Encoder switch, 739
Pin assignment, 740
ESD
Electrostatic discharge, 16
grounding, 16
workplace, 16
ESDsensitive components, 16
Excess temperature, 613
External enable, 72, 78, 711, 717, 721, 81,
86
F
Filter capacitor, 515
Dimensions, 1010
Frequency warning, 727
Fuses, 113
G
Gear encoders, Permitted types, 735
Grounding bracelet, 16
H
Highspeed analog outputs, 750
Holding brake, Control, 729
I
Installation
Backplane modules, 33
Cold module, 37
DMA..K, 31, 32
VMW..F (water cooling), 34
Intended use, 11
1070066030 / 06
ServoDyn D
Appendix
IT protective system, 51
L
Limit current, 723
Limit switches, 79
Line cross section
Supply VMA 21KR, VMA 35B, VMA 70C, 510
Supply VMA 90D, 512
Supply VMA..K, 57
Supply VMW 180F, 514
Line reactor
Connection for VMA 90D, 513
Connection for VMA..KR and VMA..B,C, 511
Connection for VMW 180F, 515
Dimensions NE 180/A, 109
Dimensions NE 21/B, 106
Dimensions NE 21/C, 107
Dimensions NE 35/A...NE 100/A, 108
Function, 21
Line wiring module, 21
Block diagram, 57
LowVoltage Directive, 11
M
Machinery directive, 11
Mains connection
Autotransformer, 56
Line cross section VMA 21KR, VMA 35B, VMA
70C, 510
Line cross section VMA 90D, 512
Line cross section VMA..K, 57
Line cross section VMW 180F, 514
Mains connection module NAA 180, 514
Mains connection module NAA 25, NAA 35, 510
Mains connection module NAA 90, 512
NV line wiring module, 57
Mains connection module
Block diagram NAA 180, 514
Block diagram NAA 25, NAA 35, 510
Block diagram NAA 90, 512
Dimensions NAA 21, 102
Dimensions NAA 35...90, 103
Function, 21
Mains failure, 612
Mains filter, 56
Connection, 58
Dimensions, 1011
Function, 21
Mains supply, 55
Measuring probe input
VM..B,C,D,F, 614
VMA..K, 63
Message
Mains failure, 64
Ready, 63
Status, 69
A3
A4
ServoDyn D
1070066030 / 06
Appendix
Standstill monitoring, 727
Start logically linked
VMA..KB, VMA..KE with other interfaces, 66
VMA..KB, VMA..KE with SERCOS interface, 67
Status message, 72, 78, 711, 717, 721
Supply modules
Dimensions VMA 21 KR, 102
Dimensions VMA..B,C,D, 104
Dimensions VMW..F, 105
Function VMA..K, 22
Function VMA..KR, 22
Supply modules VM..B,C,D,F, Plugin connection
X99, 734
Supply modules VMA..B,C,D
Connections overview, 68
Terminal strip X32, 611
X810 plugin connection, 615
X820 plugin connection, 616
Supply modules VMA..K
Connections overview, 61
Terminal strip X312, 62
X810 plugin connection, 64
X820 plugin connection, 65
Supply modules VMA..KB, VMA..KE, Start logic and
EMERGENCYSTOP, 65
Supply modules VMA..KR, Connections overview,
68
Supply modules VMW..F, Connections overview, 68
Switch cabinet structure, 21
Example of a possible layout, 26
T
Temperature warning
all inverters without ASM, 731
ASM, 723
Terminal box, 529
Terminal strip X06, 69
Analog interface, 72
CAN bus, 711
DM..8001 (ASM), 721
Frequency inverter, 721
Motion Control, 72
PROFIBUSDP, 717
SERCOS interface, 78
Terminal strip X12, 76
Terminal strip X13, 723
Terminal strip X14, OM 04, 750
Terminal strip X21, 74
Terminal strip X22, 75
Terminal strip X23, 724
Terminal strip X30, 62, 611
Terminal strip X312, 62, 614
Supply module VMA..K, 62
Terminal strip X34, 612, 728
Terminal strip X34 (ASM), 727
Terminal strip X76, 732
Bosch Rexroth AG
Electric Drives and Controls
P.O. Box 13 57
97803 Lohr, Germany
Bgm.-Dr.-Nebel-Str. 2
97816 Lohr, Germany
Phone +49 (0)93 52-40-50 60
Fax
+49 (0)93 52-40-49 41
service.svc@boschrexroth.de
www.boschrexroth.com
1070066030
Printed in Germany
DOK-SERV*D-IF*MANUAL**-MA06-EN-P