Novec 1230
Fire Protection Fluid
3M and Novec are trademarks of 3M Company.
The information in this document contains general descriptions of technical options available,
which do not always have to be present in individual cases. The required features should therefore
be specified in each individual case at the time of closing the contract.
13
12
13
Ex zone devices
To guarantee continuity in case of power failure,
a data center is always connected to an uninterruptible power supply (UPS). In some of these
explosion-hazard areas, such as battery rooms
or gas generators, Ex devices have to be used.
12
Desigo
MM8000 Client
Customer network
Ethernet
Security
module
(rewall)
FN2009-A1
Security module
(firewall)
FN2009-A1
Remote access
E100
BACnet/IP
Ethernet switch
FN2008-A1
TCP/IP
AC
Water
Power
Intrusion
Access
Ethernet switch
FN2008-A1
Backbone (FCnet/LAN)
Ethernet switch
FN2008-A1
CAB-1 housing
Art. no.:
S24235-C20-A1
Ethernet switch
FN2008-A1
Manual call
point
FDM223
Video
FDnet
Alarm
sounder
FDS221
Fire control panel
FC2020
Art. no.: A5Q00016827
Data centers are critical as the heart of many companies information infrastructures. No company can accept
the failure of its networks and servers because no business can afford downtimes or the loss of irreplaceable
data and market presence. For some industries, even one or two hours of downtimes can be devastating. Thats
why its important to provide your data center with the highest level of safety.
Sounder base
FDSB291
Floor repeater
terminal FT2010
Fire terminal
FT2040
Art. no.: A5Q00016720
Cluster (FCnet/SAFEDLINK)
Our fire safety solutions are tailored exactly to your data centers requirements. They offer you maximum safety
against all risks of fire and ensure uptime and availability of service. Based on the concept of a single, innovative
partner, we provide everything from fire detection to extinguishing, and from system design to installation and
after-sales service.
Air sampling
chamber ASD Duct FDBZ292
Basic set FDBZ292
Art. no.: A5Q00021362
Electronic FDME221
Art. no.: A5Q00002451
Integrated and
innovative safety
Input/output module
FDCIO222
Art. no.: A5Q00002369
Highlights
Alarm sounder FDS221-R
Art. no.: A5Q00004117
FDnet
+DC 24 V
DA heat detector
FDT221
Art. no.: A5Q00001567
n
yg
e
Sinorix CDT
Combustible
at
Sinorix 1230
He
Combustible
(optional)
n
yg
e
Ox
Sinorix HO Gas
at
Cylinder battery
He
l
s
tr y
tr y
cts
ma
a re
t ai
rg y c o m u r i n g v i c e
ion
R e P h a r l t h c ro d u r t a t n d u s n d u s
r
le
t
e
c
e
s
a
o
i
i
T
fa ial
rp
sp
ia
el
He
nu
c
me Tran Med Trav
Ma inan
su
n
F
Co
e
En
Ex zone
FDnet
Gas
3.0
2.5
2.0
1.5
1.0
0.5
0.0
Input/output module
transponder FDCIO223
Art. no.: S24218-B102-A1
Cost of downtime per hour in mio. US $ (Source: Data Center Journal, July 2007)
Ox
DA wide-spectrum smoke
detector FDO221
Art. no.: A5Q00001565
yg
e
DA neural re detector
FDOOT221
Art. no.: A5Q00001566
Ox
at
Plus, we take care of your system throughout its life cycle, including risk analysis,
project management, and choosing the
right systems and the best service concept.
For an overall secure and energy-efficient
data center, our integral concept also
VLF-500
Art. no.: VLF-500
He
VLF-250
Art. no.: VLF-250
Sinorix HO Gas
LaserFOCUS
Combustible
Detector base
DB1101A
Art. no.:
BPZ:4863650001