Anda di halaman 1dari 2

Order form configurator

MiCOM P145
Ready-to-use configuration
1-4

Feeder management with autoreclose and check synchronising

P145

Design Suffix: Options based on preferred solutions selection here


J: Grey/Grey case, dual characteristic opto inputs, IEC61850, InterMiCOM

Software
46:
44:
43:
42:
41:
36
35:
31:

Options Design Suffix dependent

=S= rebrand release, load encroachment, cyber-security, programmable curves etc.


Addition dv/dt prot, 128 Virtual Inputs, 6 O/C Stages
Adv.Freq.prot, Power prot
IEC 61850 Enhancement
Second Harmonic Blocking/DNP3 aliased Control Inputs

44

IEC 61850 Protocol, IEC60870-5-103 with generic measurements


Initial Release

Vx Aux Rating
24 - 48Vdc
48 - 110Vdc
110 - 250Vdc (100 - 240Vac)

In/Vn Rating
In = 1/5A, Vn = 100-120Vac
In = 1/5A, Vn = 380-480Vac (Min 196Vac Max 560Vac)

Hardware Options
Standard - None
IRIG-B (Modulated) Only
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3)
Fibre Optic Port (ST) for SCADA Protocols (Courier,Modbus,IEC60870-5-103 or DNP3) + IRIG-B (Modulated)
Ethernet (100Mbit/s)
Courier Rear Port
IRIG-B (Modulated) & Courier Rear Port
Ethernet (100Mbit/s) plus IRIG-B (Modulated)
Ethernet (100Mbit/s) plus IRIG-B (De-modulated)
InterMiCOM + Courier Rear Port
InterMiCOM + Courier Rear Port + IRIG-B modulated
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet Self-Healing Ring, 2 multi-mode fibre ports + Un-modulated IRIG-B
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet RSTP, 2 multi-mode fibre ports + Un-modulated IRIG-B
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Modulated IRIG-B
Redundant Ethernet Dual-Homing Star, 2 multi-mode fibre ports + Un-modulated IRIG-B

Product Specific Options


16
12
24
16
24
32
16
16
24
16
16

logic
logic
logic
logic
logic
logic
logic
logic
logic
logic
logic

inputs
inputs
inputs
inputs
inputs
inputs
inputs
inputs
inputs
inputs
inputs

&
&
&
&
&
&
&
&
&
&
&

16
12
16
24
24
16
32
20
20
28
24

relay
relay
relay
relay
relay
relay
relay
relay
relay
relay
relay

outputs
outputs
outputs
outputs
outputs
outputs
outputs
outputs
outputs
outputs
outputs

with ANSI Symbol Terminal labelling

J
(including
(including
(including
(including

4
4
4
8

High
High
High
High

Break)
Break)
Break)
Break)

Protocol/Communications Options
IEC 61850 and Courier via rear K-Bus/RS485
IEC61850 over ethernet with CS103 rear port RS485 protocol
DNP3 over Ethernet with Courier rear port K-Bus/RS485 protocol

Mounting Option

Flush Panel Mounting

Language
Multilingual - English, French, German, Spanish
Multilingual - English, French, German, Russian
Chinese, English or French via HMI, with English or French only via Communications port

Customisation
Default

Default
Customer

16/10/2012

10

11

12-13

14

15

3 1 G J 7 M 0 44 8