,Ltd
2 F, 37#, Wanghai Road, Software Park 2, Xiamen,China (361009)
Contact person: Michelle E-mail: sales06@caimore.com
Skype: caimoremichelle
Mobile phone: +86-15080025764
Caimore,
Abstract: This article provides a video surveillance system design principles and
implementation of a CDMA2000 EV-DO 3G network is based, introduced the
basic knowledge of CDMA2000 technology, describes the implementation EVDO
3G wireless transmission used in image monitoring system. The practical
Web: www.caimore.com/emain.asp
Preface
In recent years, video surveillance for its intuitive, easy to use, rich content
and are widely used in many important occasions, it has become the primary
means of security surveillance. With the rapid development of communication
technology and computer network technology, wireless network technology
has become a computer network in a vital part, but also the rapid expansion of
its applications. Due to the remote video monitoring system to achieve the
goal of remote monitoring, remote control and other functions, providing new
tools for unattended applications. CDMA technology enables cost appears
reasonable, relatively low technical threshold of wireless data transmission
technology site in the monitoring system to the real-time data transmission
remote monitoring center possible.
Web: www.caimore.com/emain.asp
Web: www.caimore.com/emain.asp
-----------------------------------------------------------------------------------------------------------
Web: www.caimore.com/emain.asp
-----------------------------------------------------------------------------------------------------------
terminal
and
the
monitoring
center
is
based
Socket
Communications.
Web: www.caimore.com/emain.asp
----------------------------------------------------------------------------------------------------------DTU Camera data interface is RJ45 interface, using a + 5V supply input. Pin
function as follows: |
CAPEN: used to enable or disable the Camera DTU output image. CAPEN
= 1, allows the output image, CAPEN = 0, then disable the output image.
JPEGD7..JPEGD0: parallel data output. 8 output image data in this group
of pins.
JPEGINT: DTU from the camera to an external microcontroller interrupt
signal is a positive pulse width of about 10us, the microcontroller can trigger
an interrupt on the falling edge of this signal. This interrupt signal indicates
that the output has a new image data on the JPEGD7..JPEGD0 pins.
DTU Camera has an internal reset and initialization process after power
enters the standby mode after initialization is complete. In the standby mode,
the camera DTU loop checks CAPEN pin, if CAPEN = 1, in the
JPEGD7..JPEGD0 pin continuous output data, each output data, to generate
an interrupt signal on JPEGINT pin to notify the micro The controller reads the
data. DTU Camera output is a complete JPG file, JPG file is always "0XFF",
"0XD8" start and "0XFF", "0XD9" end. The microcontroller checks the
received data, when receiving "0XFF", when "0XD9", indicates that the file end,
this acquisition is complete. Then Camera DTU will return to the standby
mode.
Microcontrollers TMS320LF2407A, clocked at 40M, IOPC mouth used to read
data DTU Camera, camera DTU interrupt output (CAPINT) connected to
TMS320LF2407 of XINT1, falling edge; output enable (CAPEN) connected
IOPE0. TMS320LF2407 expanded 64K bytes of SRAM as an image cache.
Because Camera is used DTU +5 power supply, TM320LF2407 uses a + 3.3V
power supply, so the interface must solve level conversion.
Web: www.caimore.com/emain.asp
-----------------------------------------------------------------------------------------------------------
Web: www.caimore.com/emain.asp
---------------------------------------------------------------------------------------------------------- After power automatic dial-up, has been online, disconnected automatically
connect;
transparent data transmission mode, the parameters can be set freely;
MSCBSC Mobile Communications Forum;
support dynamic data center domain names and IP addresses;
support for audio interface for easy maintenance operations;
System configuration and maintenance interface;
Power interference and heat dissipation, harsh working environment;
Before using CDMA RUTER must set parameters to decide to enter
transparent data transfer mode works. Parameters need to be set are: the
monitoring center IP address (or dynamic domain name server can resolve the
domain name) and port number; Socket communication type (TCP or UDP);
communication interface parameters; trigger mode settings.
CDMA RUTER after each boot automatically dial the access CDMA and
dynamically obtain an IP address, this IP address is CDMA backbone network
addresses, without entering the connected state, the server (monitoring center)
is not directly communicate with the CDMA RUTER a. CDMA RUTER initiative
to connect to the server to send the data. When the connection route is
established, the server and the terminal can double the site for data
transmission. The route has a time limit, generally only tens of seconds, in
order to ensure that the link has been smooth, CDMA RUTER has a link
keep-alive function, by regularly sent: "Heartbeat" packets, maintain routing
(dynamic IP by the terminal and the server ISP service providers to
dynamically allocate server, if a long time do not communicate, ISP server will
reclaim IP, in order to facilitate the effective use of IP resources) to ensure
timely mutual communication between the server and the terminal, so the
monitoring center can actively sends data to the image capture terminal
acquisition command and other parameters. In addition, the "heartbeat"
Tel:+86 592 5901215
Web: www.caimore.com/emain.asp
----------------------------------------------------------------------------------------------------------packet contains the ID information of the terminal, so the server can easily
determine industry source routing and data packets.
Web: www.caimore.com/emain.asp
-----------------------------------------------------------------------------------------------------------
10
Web: www.caimore.com/emain.asp
----------------------------------------------------------------------------------------------------------IV. Conclusion
With increasing levels of production management, remote video remote
monitoring has been widely used, more and more mature, and is moving
network, intelligent direction. CDMA wireless transmission of data using the
communication method to solve the communication problem of remote
monitoring system, compared to other wired communication has incomparable
superiority. Since the transmission of the image data, the amount of data and
more frequent, may choose not to limit the use of business packages more
economical. Our laboratory constructed in the wireless video remote
monitoring, to obtain the desired results. Moreover, with the gradual
improvement of mature CDMA network and application technology, CDMA
applications will be more broad. CDMA wireless transmission system
presented here can be extended to a variety of needs testing, monitoring and
security of the environment.
11
Web: www.caimore.com/emain.asp