Anda di halaman 1dari 93

Operation Guide

Designer Software

Part Number 2-450202-010


manual revision v2.0 2nd March 2009
Vision Net Designer

Page 2 © Philips 2009


Vision Net Designer

Table of Contents
Welcome 6
Vision.Net 7
Vision.Net Overview 8
Communications 9
Vision.Net Designer Software 10
Vision.Net Designer 11
Menus 12
File 12
Tools 14
Setup 15
Interface 16
Operating Style 18
Mode Maps 19
Real Time Clock 21
Maps: Display/Unlock All 22
Help 22
Tool Bars 23
Main Tool Bar 24
Status Bar 26
Status Bar 27
My Network Tree 28
Group/Rooms 29
Control Stations 30
Buttons 31
Slider Faders 33
Station ID 34
Saving and Loading Station Configurations 35
Saving to a Station 36
Loading from a Station 37
Custom Panels 38
Touch Screens 39
Touch Screen Tool Bar 41
Screen Design 43
Touch Screen Tabbed Views 44
Touch Screen Buttons 47
Touch Screen Slider 48
Touch Screen Slider Panels 50
Touch Screen Raise and Lower 51
Touch Screen Text 52
Touch Screen Clock 53
Loading Touchscreen 55
Output Devices 57
Adding Devices 58
Simulations 62
Palette OS 63
Real Time Clock 66
Timed Events 67
Vision.Net Component Connections 71
Page 3 © Philips 2009
Vision Net Designer

Button Stations 72
DMX Interface 73
Fader Stations 75
RS232 Station 76
Palette 78
Portable Stations and Screens 79
Appendix 80
Button and Event Actions 81
Smart Buttons 86
Touch Screen Maintenance 87
Trouble Shooting 88
Offices and Service Centres 89

Page 4 © Philips 2009


Vision Net Designer

Page 5 © Philips 2009


Vision Net Designer

Welcome to Vision.net Designer

Date: March 2009

Software v2.0.0 or later

Congratulations on the purchase of your Strand Lighting Vision.net System software.

For general help, use the Contents, Index or Search tab on the left.

Getting Technical Support

For technical support, please refer to the Strand Lighting Offices and Service Centres

Part Number 2-450202-010


manual revision v2.0.1b 2nd March 2009

Page 6 © Philips 2009


Vision Net Designer

Page 7 © Philips 2009


Vision Net Designer

Vision.net

Overview.
The Vision.net System is designed to control architectural lighting by distributing both power and intelligence.
The system provides processing power and control at each respective Master or Remote Station, eliminating
the need for a central processor.

Master Stations provide individual control for up to 15 channels, 8 scenes plus “Off”, all with adjustable fade
times. Multiple Stations may be linked together for control of up to 127 Channels and 32 preset scenes.

By combining Vision.net Master Stations with Vision.net Preset Stations, the system provides remote access to
scenes, Master Raise/Lower control, Multi-room partition control, or Master Station Lockout.

In the basic configuration mode the room number can be set on Vision.net Master Stations using the front panel
buttons, without removing the Master Station from the wall, and without the need for a computer.

Vision.net Touch Screens allow fully customised displays that are easy to configure and may be programmed
over an ethernet link. Portable and Fixed screen options are available.

Vision.net Master Stations are compatible with Strand Lighting A21, R21, C21 and EC21 Dimming Cabinets and
the Vision.net DMX512 Output board.

Vision.net products are controlled by the Vision.net System protocol. All Vision.net control devices must be
connected to the Vision.net system and given a unique ID (or address) in order to interact properly. The ID
identifies the device on the network and allows the device to avoid network collisions when transmitting data

Vision.net Components
Components that make up a Vision.net work include, but are not limited to the following:
 C21 and EC21 Dimmer Racks
 A21 and R21 Dimmer Racks
 Contact Relay Panel
 Vision.net DMX512 Output Board
 N21 Network Nodes
 8 Push Button Control Panels
 3 Slider Stations and Slider Master Stations
 6 Slider Stations and Slider Master Stations
 9 Slider Stations and Slider Master Stations
 12 Slider Stations and Slider Master Stations
 15 Slider Stations and Slider Master Stations
 Vision.net Connection Stations
 Palette and Light Palette Control Consoles
 Rack Palette Architectural Control System
 7", 10" and 15" Touch Screen Panels

Page 8 © Philips 2009


Vision Net Designer

Vision Net Communications

Overview
A Vision.net system uses an RS485 multi drop cabling system for communications between the various devices
on the Vision.net network. This includes Buttons Stations, Fader Stations and Various other devices such as
touch screens and other output devices.

In addition to using RS485, certain devices can also use an Ethernet connection for communications. This for
example includes the latest Touch Screens and the Vision.net Designer software. Using Ethernet as the
communications medium for Touch Screens, allows you further enhanced control of the screens, allowing new
software and configurations to be uploaded directly from Vision.net Designer.

A gateway will be required to convert the Ethernet signals to the Vision.net RS485 data. Suitable gateways can
be provided and you should consult Strand Lighting for more details.

Vision.net uses distributive processing techniques, whereby reliabilty is significantly increased over those of
centralised processing systems. Intelligence is distributed across the network with output devices storing only
the data that they need, reducing cost. As result of in the case of a failure, the fault is locally contained, rather
that compromising the entire system, as would be the case in a centralised system.

Page 9 © Philips 2009


Vision Net Designer

Page 10 © Philips 2009


Vision Net Designer

Vision.net Designer Software

Overview
Vision.Net Designer is a software program allowing the configuration of a Vision.net system to be designed,
monitored and modified.

The configuration tool is a powerful Graphical application, allowing devices to be added, monitored or changed
in an easy to use "Point and Click" environment. Common features, such as Copy & Paste and other Windows
environmental tools make designing your system a fast and pleasurable experience.

Most items are selected from Tool bars, which are context sensitive to the area that you are working in.
Properties of these items are then set, either using the Properties Icon on the device or toolbar, or by using the
mouse and right clicking to expose a drop down list of actions for the device.

The main screen is divided into areas, Device Tree, Devices Window and Status Bar. In addition to these there
is the menu bar with options of File, Tools and Help.

Note: When you first open Vision.Net Designer, it will open in one of three Operating Styles. You
can change the current operating style from the Style Selection button on the toolbar. A
password may be required to change the style (see Tools - Setup in the Menu Bar).

Page 11 © Philips 2009


Vision Net Designer

File

File Menu

The File menu gives access to File actions, for example building a New configuration, Opening existing
configuration files, Saving Configuration files and setting the system to work off line.

Tip: When not connected to a Vision.net system, you should ensure that the “Work Off Line”
option is selected in the File menu

New Displays a New Vision.net Project

Open Open an existing Vision.net Project

Recent Files Produces a list of recently used Vision.net Projects

Save Save your current Vision.net Project

Save As Save a copy of your Vision.net Project as a new name or in a new folder.

Page Setup This opens up the Printer properties, which is used when printing Output
Device information. See Output Devices for more information

Page 12 © Philips 2009


Vision Net Designer

Work Off Line Selects Off Line working

Exit Closes Vision.net Designer

Page 13 © Philips 2009


Vision Net Designer

Tools

Tools Menu

The tools menu gives access to the system Setup screens and allows the configuration of the communication
settings for connection to the Vision.net network.

Setup Displays the Setup Screen

Maps: Clears any display modes and unlocks statons.


Display/Unlock
All

Page 14 © Philips 2009


Vision Net Designer

Setup

Setup
The Setup tool displays the setup dialog where you can select a different Operating Style, setup Mode Maps
and select settings for a Real Time Clock.

Setup dialog box

Page 15 © Philips 2009


Vision Net Designer

Interface

Serial Port

This allows the choice of the serial port that Vision.net Designer will use to communicate with components of
the system.

Ethernet Port

Selecting the Ethernet option, allows Vision.net Designer to connect to the Vision.net network over an Ethernet
link.

Note: When connecting to an Ethernet network, Vision.net Designer must be connected to the
same subnet as the Vision.net Gateway.

Page 16 © Philips 2009


Vision Net Designer

Page 17 © Philips 2009


Vision Net Designer

Operating Style

Operating Style
The Vision.net designer software runs in one of three different modes. You can configure the system to
automatically start in one of these modes. The default mode of operation will be Designer Style.

Monitor Style
In Monitor Style, Vision.net Designer allows the software to mimic the state of the Vision.net network, but not to
change the state of devices.

Mimic Style
In Mimic Style, Vision.net Designer allows the software to mimic the state of the Vision.net network, and to
change the state of devices.

Designer Style
In Designer Style, Vision.net Designer allows the software to change all aspects of the system.

Tip: You can force Vision.net designer to start up in Mimic or Monitor Style. You can also set
a password to protect the Designer Mode by selecting the “Password Required to Change
Style” and entering a numeric password.

Page 18 © Philips 2009


Vision Net Designer

Mode Maps

Mode Maps

Mode Map Configuration Screen

Different Modes are used to mask features and facilities of a system to reflect the current state of operation.
You can define up to 8 different modes, each mode can be password protected if desired.

The different modes and their passwords are set in the setup in the Mode Maps section of the Setup.

Mode Name This is an area for text entry, allowing you to enter a name to easily identify
the mode.

Password This is a six number password required to change the system to the
requested mode.

Note: Password Entry is only possible from a touch screen


on the system.

Passwords
When a user selects a different mode from a touch screen, a numeric keypad will appear allowing a password
to be entered.

Page 19 © Philips 2009


Vision Net Designer

Example Keypad

For example you might configure two modes of operation, one for Daytime operation and one for Night Time
operation or one for Show Mode and one for Rehearsal Mode.

Note: A default "Admin Mode" with a password of 1234 is always set whenever you create a
new Vision.netDesigner file.

Page 20 © Philips 2009


Vision Net Designer

Real Time Clock

Real Time Clock


Real Time and Astronomical events can be set to run on Vision.net For this purpose, a PC running Vision.net
Designer can be connected to the network and can be set to trigger such events.

To enable this mode of operation, simply enable the Real Time Clock on the PC in the Setup. The default for
this setting is for the real time clock function to be Disabled. When disabled, a Real Time clock can be set to
run on a Touch Screen if required. See Real time Clock.

Real Time Clock Enable Screen

For more information on setting Real Time Clock Events, please refer to the Real Time Clock section.

Note: Modification of the Real Time clock is only possible when the system is running in the
Admin Map or All Map mode.

Page 21 © Philips 2009


Vision Net Designer

Maps: Display/Unlock All

Maps: Display/Unlock All


Show All Maps, allows the Vision.net Designer to be defaulted back to a mode where all components can be
seen, even if that have been hidden in certain modes. This can be useful where elements have been hidden;
as a result of selecting a mode, when testing.

When show modes are shown, Enable All Modes will briefly display in the Status Section of the screen.

Vision.net Designer Status Bar

Help

Help Menu

The Help menu gives access to

Contents Displays this Help file

Index Displays the Index tab of this help file where you can search by a keyword

Reset Warnings

About Displays the splash screen showing the Product name and current version

Page 22 © Philips 2009


Vision Net Designer

Page 23 © Philips 2009


Vision Net Designer

Main Tool Bar

The Main Tool Bar gives you access to the following

The Main Tool Bar

Save Save the configuration for archive purposes. Vision.net Designer files are xml
based, making them future proof.

Tip: By using Vision.net Designer in a design team, you can


exchange Vision.net Designer files between team members
to convey ideas and operation of the system. Due to the
compact nature of the Vision.net Data files, these are small
enough to be emailed easily.

Add to
Network

Add to Network drop down list

Use this to add Main items to your Network Tree, these for example are
Rooms/Groups, Custom Panels, Touch Screens, Output Devices or Real Time
Clocks.

Simulate Use the Simulations buttons to create simulations of Dimmer Racks, or DMX
Control Devices.

This will help you get an idea of how your system will work when you install it. The
simulation tools make understanding your system very easy and it is a very quick
way to communicate ideas.

Design Style

Operational Style drop down list

Use the Operation Style button, to choose the mode that Vision.net Designer runs
in.

Page 24 © Philips 2009


Vision Net Designer

Page 25 © Philips 2009


Vision Net Designer

Page 26 © Philips 2009


Vision Net Designer

Status Bar

A status bar is shown at the bottom of the screen. The status section also shows a progress bar, when
uploading or downloading to the Vision.net network.

Vision.net Designer Status Bar On Line

The small icon on the status bar, allows you to display upto the last 20 commands that were seen on the
Vision.net network. This is useful for testing and fault finding purposes.

Note: The communications port is enabled or disabled through the File menu and the Work Off
Line setting. When working Off Line, the status bar will show as being OFFLINE flashing
Red.

Vision.net Designer Status Bar OffLine

Page 27 © Philips 2009


Vision Net Designer

Page 28 © Philips 2009


Vision Net Designer

Concepts
A Group or Room is a collection of circuits and Control Panels, all dedicated to adjusting the lighting in a
particular zone of the building.

Adding a Group to the Network


Using the Main Tool Bar, click on Add to Network and select Room/Group. A dialog box will appear, prompting
you for the Group’s Name and ID number. The ID number will be used as a short cut to refer to this room later.

When the room is added it will appear in the directory tree under Group (Room) with the ID number and Name
that you gave it.

Room Example with Panels added to it

Tip: You can simulate the output of a dimmer rack or input of a DMX device by using the Rack
or DMX simulation buttons. See the Simulations section for more details.

Page 29 © Philips 2009


Vision Net Designer

Control Stations

Concepts
To control the lighting in a Zone or Room, Control Station are used. These stations can be either push button
stations, slider fader stations or slider and button stations. Touch Screens may also added to the system, but
they are added separately.

Panels are added to the room by using the Control Station Toolbar and then configured by changing the various
properties of Buttons and Slider Faders on the panel.

Control Station Toolbar

You can then set a physical station to this configuration, first by setting the Physical Station ID. Configurations
may then be either transferred to and from Vision.net Designer and the designated Station (see Saving and
Loading Station Configurations)

Page 30 © Philips 2009


Vision Net Designer

Buttons

For each Push Button on a push button station you can configure what action the button performs.

For each button on the station you can then set the following properties:

Button Label A descriptive name for the button or what its purpose is.

Note: When you change the Button Type the Label will
automatically be set to reflect the button type.

Button Type The Button type gives a drop down list of all the button actions you can set.
The list contains various button types for example:
 Console Button
 Genlyte Scene (for use with other Genlyte products)
 Lower
 Preset
 Preset On/Off
 Raise
 Room Link
 Select Mode
 Share Button
 Smart
 Smart Mimic
 Toggle Channel
Depending on the button type, other options will appear see Button Actions
for more details

Tip: Use the “all buttons on this station have the same
style” option to quickly change all the buttons to the
same type.

Press and Hold Vision.net provides a very easy feature for recording Presets in the
Learn system. By default, preset selection buttons also allow the current scene
to be recorded by pressing and holding the required preset button for 3
seconds.

Tip: You may want to disable this feature on certain


buttons to ensure that the lighting levels do not
accidentally become overwritten. Do this by
selecting the "Disable Press-Hold Learn" check box
for the button concerned.

Note: Press and Hold Learn is only available on Preset


and Preset On/Off buttons.

Mode Map Using the Mode Map button, you can define if that button is operational
when the system is set in different modes. By default the button will be
available in all modes.

Page 31 © Philips 2009


Vision Net Designer

Page 32 © Philips 2009


Vision Net Designer

Slider Faders

Different fader types can be set depending on the panel type chosen the faders can be either:
 Channel Faders.
 Extensions to another Channel Fader board
 Submaster faders

Slider Room Here you set the Room that the faders reside in and the number of faders
that are on the panel.

Number of Select the number of faders from the drop down list.
Sliders

Mode Map Using the Mode Map button, you can define if the faders are operational
when the system is set in different modes. By default the button will be
available in all modes

Page 33 © Philips 2009


Vision Net Designer

Station ID

Setting a Station’s Vision.net Network ID


Step 1. Connect the PC running the Vision.net Designer software to the Vision.net Network via
the Vision.netRS232 station, using an RS232 lead. Please contact your local Strand
Lighting Office for more details on this interface.
Step 2: Set Vision.net Designer to work “On Line”.
Step 3: Select or add the required station from the Network Tree and press the Station Id button.
Step 4: Select Set Station ID and the LED indicators of all unassigned stations will flash.
Step 5: Press and Hold any button on the required station for 3 seconds and the station’s ID will
be set.

Setting a Stations ID Address

Changing the Vision.net Network ID


Step 1: Connect the PC running the Vision.net Designer software to the Vision.net Network via
the Vision.netRS232 station, using an RS232 lead. Please contact your local Strand
Lighting Office for more details on this interface.
Step 2: Set Vision.net Designer to work “On Line”.
Step 3: Select or add the required station from the Network Tree and press the Station Id button.
Step 4: Select Change Station ID and the LED Indicators of all stations will flash.
Step 5: Press and Hold any button on the required panel for 3 seconds and that Station will be set
to the current station ID. Any other station that is currently set to that Id will have its ID
cleared.

Changing a Stations ID Address

Page 34 © Philips 2009


Vision Net Designer

Saving and Loading Station Configurations

Configurations
Once you have designed your configuration for a particular control station, you can upload the configuration to
the station(see Saving to a Station for more details).

If you have already uploaded a configuration to a Station and want to see what it is, you can also download the
configuration from the Station into Vision.net Designer (see Loading from a Station for more details).

Page 35 © Philips 2009


Vision Net Designer

Saving to a Station

Saving the Configuration to the Station


Step 1. Connect the PC running the Vision.net Designer software to the Vision.net Network via
the Vision.netRS232 station, using an RS232 lead. Please contact your local Strand
Lighting Office for more details on this interface.
Step 2: Set Vision.net Designer to work “On Line”.
Step 3: Select or add the required station from the Network Tree and set the required mode for
each button as desired.
Step 4: Select Upload & OK and the configuration set in the Vision.net Designers software will be
saved to the station.

Example of a Stations Configuration before uploading it to the panel

Note: If the upload process fails, a warning will appear advising that the communications to the
panel are unreliable. If this occurs, check that you have a good connection to the Vision.
net network and that there is a panel with the ID that you are trying to download the
information to. See Trouble Shooting..

Page 36 © Philips 2009


Vision Net Designer

Loading from a Station

Downloading the Current Configuration from the Station


Step 1. Connect the PC running the Vision.net Designer software to the Vision.net Network via
the Vision.netRS232 station, using an RS232 lead. Please contact your local Strand
Lighting Office for more details on this interface.
Step 2: Set Vision.net Designer to work “On Line”.
Step 3: Select or add the required panel from the Network Tree and press the Get Configuration
from Station button. The current configuration loaded in that panel will be downloaded to
Vision.net Designer.

Once the information has been downloaded the current configuration of the station will be displayed

Example of a Stations configuration after download

Note: If the upload process fails, a warning will appear advising that the communications to the
panel are unreliable. If this occurs, check that you have a good connection to the Vision.
net network and that there is a panel with the ID that you are trying to download the
information to. See Trouble Shooting

Page 37 © Philips 2009


Vision Net Designer

Custom Panels

Concepts
A Custom Panel selection is a collection of Control Stations that are generally grouped together in a location
and which may control one or more Groups or Zones. An example of this, could be a central Control Room
controlling several Rooms or Zones, or a Stage Managers Panel, where control is available for House Lighting,
Working Lights and other show state lighting.

Once a Custom Panel is added to the network, individual Panels are then added to this location in the same
was as adding Panels to a Group or Room using this Custom Panel Add Toolbar. See Control Stations for
more details.

Adding Custom Panels to the Network


Using the Main Tool Bar, click on Add to Network and select Custom Panel. A dialog box will appear, prompting
your for the Custom Station's Name and ID number.

Page 38 © Philips 2009


Vision Net Designer

Touch Screens

Concepts
Touch screens are top level control components that provide a highly customisable interface to the Vision.net
network. They are very flexible and provide a highly intuitive and easy to use way of working with the Vision.net
system.

Adding Touch Screens to the Network


Using the Main Tool Bar, click on Add to Network and select Touch Screen. As with adding other devices, a
dialog box will appear.

The Screen Dialog Box

Naming the Screen


You start by giving the screen a name to identify it form others that might also be part of your system. Do this
by entering the name in the Name filed of the screen dialog box.

Choosing the Screen Size


Next you will define the size of the screen to be used. Your choice will depend on the size and type of Vision.
net touch screen that you are using and are as follows

 QVGA - Quarter VGA Screen (320 x 240)

 WVGA - Wide VGA Screen (800 x 480)

 VGA - Standard VGA Screen (640 x 480)

 SVGA - Super VGA Screen (800 x 600)

 XVGA - Extended VGA Screen (1024 x 768)

Screen Styles
Once you have chosen the screen size, you need to define the overall layout template that will be used for the
screen. The four templates that are available are as follows:

 Full Screen

 Split Screen

 Split Screen Horizontal

 Split Screen Vertical

 Split Screen Horizontal and Vertical

ID Number
As well as a system name, which you entered into the dialog box, you will also need to give the screen an
address for the system to work with. This you enter into the ID Number box. This number auto increment's

Page 39 © Philips 2009


Vision Net Designer

each time you add a new screen to the system for your convenience.

Tip: If you wish to use Vision.net Designer running in Monitor or Mimic mode, you can design
a screen specifically for this purpose. If you do so, set the Virtual Screen option in the
dialogue box.

Note: Smart button commands are only sent from the Vision.net Designer PC if the software is
running in the Design style or it is a virtual Touch Screen when running in the Mimic
Style.

Once the screen settings have been decided, pressing OK will add the new screen to the system.

Page 40 © Philips 2009


Vision Net Designer

Touch Screen Tool Bar

The Touch Screen Tool Bar gives you access to the following

Touch Screen Toolbar

Properties This brings up the touch screen properties dialogue box

Export Exports the screen definition so that it can be loaded into the
touchscreen (see Loading Touchscreen)

Duplicate Creates another screen on your system with an identical layout.

Grid Displays or Hides the touch screen alignment grid

Touch Screen Properties Dialogue Box

Using this dialogue, you can configure Screen


Savers, Connections settings and a connection to a
Philips Color Kinetics Show Controller.

Page 41 © Philips 2009


Vision Net Designer

Page 42 © Philips 2009


Vision Net Designer

Screen Design

Designing Screens
With the screen added, it will appear in the Network Tree on the left hand side of the Vision.net Designer
software and a blank version of the screen will appear in the Station pane on the right, together with a set of tool
icons. You use these components and drag them onto the screen area.

Component Toolbar

Items are placed on the screen by dragging them into place. Right clicking on any item allows you to set it's
properties, copy, paste or delete it

Tip: Buttons, Sliders and Text automatically align to a grid on the screen.

You can enable/disable this alignment grid using the Grid Button on the Touch Screen
Tool Bar

Page 43 © Philips 2009


Vision Net Designer

Touch Screen Tabbed Views

Tabbed Views

Tabbed views give you a display, where you may have a different Vision.net configuration behind each table.
Adding a tabbed view to the screen automatically provides you with two tabs.

These tab buttons can be customised see bellow fro more details.

Note: Placing a Tabbed View onto an area of the screen where there is already information will
remove them and replace them with the tab view.

Right Clicking in the main body of the tabbed window then gives you options to change
the properties of that particular tab or to delete it or add an additional tab.

Tab Page Properties


Choosing the properties of the tab then brings up a dialog box so that you can set the name of the Tab, the style
of the screen, the Access Level of that Screen, together with a Background colour and image for that screen.

Touch Screen Tab Properties Dialog.

For each Tab Page you can choose one of three different overall styles. These are:
 Buttons and Sliders (the default format)
 Palette Monitor
 Web Page

Tip: The properties of the screen or items placed on the screen may be set by Right Clicking

Page 44 © Philips 2009


Vision Net Designer

with a mouse.

Background Images
By adding Backround images to a touch screen, you can either add logos or generate a geographic look to your
screen design.

Bitmap, Jpeg or GIF images can be used as background image, however keep the image file size as small as
possible. Images that are oversized will be scaled to fit the display, but trying to use the native screen
resolution is more efficient.

Tip: If you are adding graphics to the screen, try to make sure the image is the same
resolution as the touch screen that you are working with. The native resolutions are as
follows:

QVGA (320 x 240), WVGA (800 x 480), VGA (640 x 480), SVGA (800 x 600) & XVGA
(1024 x 768)

Tab Buttons Properties


Right clicking on a tab button allows you to add, move or delete the tab or select the properties of the button.

Using the Tab properties dialogue, you can


configure the appearance of the button,
including the location of tab bar, which can
either be at the Top, Bottom or completely
hidden.

The Sharing Option, allows the tab to be


actived by a Share Button on either a touch
screen or control station. Shared Buttons
can also be actived as part of a Smart
button action and allows for automated
actions.

See Button and Event Actions

Page 45 © Philips 2009


Vision Net Designer

Page 46 © Philips 2009


Vision Net Designer

Buttons

Buttons can be added to the touch screen and their properties set. From the properties you can set parameters
such as the text to display, the font, colour, style etc, as well as the buttons action.

Touch Screen Button Properties Dialog.

As well as saying what the button does, it is also possible to control when it is displayed, locked or in the case of
preset buttons, when it is able to used to record or learn presets.

Copying Buttons
Having set the properties of a button, by right clicking and selecting copy and then pasting, copies of that same
button will be added to the screen. If it is a preset or Toggle action button, each time that you paste it, it will
automatically increase the number the button refers to.

Alternatively, by holding down Control and Left Clicking the icon, a button can be also be quickly copied.

Page 47 © Philips 2009


Vision Net Designer

Touch Screen Slider Fader

Fader

Touch Screen Fader Properties Dialog.

Individual Faders can also be added to the touch screen. In the properties of the slider fader you can select it's
room channel number etc.

Faders can either be set as a Channel Fader controlling the level of a dedicated circuit or as a Rate Fader,
controlling the time of a Preset Fade for the selected room.

Rate Fader

Touch Screen Fader Properties Dialog.

Rate faders are asigned to a Room Number and any preset button, that has the rate setting set as "Slider" will

Page 48 © Philips 2009


Vision Net Designer

use the time set on the rate fader for the fade time.

When you are using the fader to control the rate of the fade of a preset on the touch screen, the Preset button's
Rate setting needs to be set to Slider.

Preset Button's Rate Properties Dialog.

If you set the button's rate setting to "Rec Slider" each time the preset is recorded, it will use the time set on the
rate fader, recording it as the fade time for that preset.

Note: In order to use this feature, both the Rate Slider and the Preset Button needs to be on the
same tab and portion of the touch screen.

Page 49 © Philips 2009


Vision Net Designer

Touch Screen Slider Fader Panels

Fader Panels

Groups of Faders can also be added.

Touch Screen Fader Panel Properties Dialog.

Page 50 © Philips 2009


Vision Net Designer

Touch Screen Raise and Lower Buttons

Raise and Lower Buttons

Raise and Lower Buttons can also be added to the touch screen, allowing individual channels to be raised or
lowered using button presses rather than faders. They have the advantage over faders since it allows you a
larger number of circuits that can be paged up or down.

Touch Screen Raise and Lower Properties Dialog.

Raise and Lower Styles


Raise and lower buttons can be used either, in proportional or absolute mode.

Proportional Raise and Lower buttons, ramp the circuit up and down and is ideal for use where you are using
portable touch screens.

Absolute Raise and Lower buttons, have the added advantage of providing a level display, however are not a
good choice for portable displays, since the it may loose synchronisation with the system and may not display
the level correctly.

Page 51 © Philips 2009


Vision Net Designer

Touch Screen Text

Text

As well as adding interactive components to the touch screen, text labels may be added as well. In common
with the main components, the text labels can be set to be hidden or shown depending on the currently selected
Mode Map.

Touch Screen Text Properties Dialog.

Page 52 © Philips 2009


Vision Net Designer

Touch Screen Clock

Clocks

You can display an analogue clock on the touch screen.

Touch Screen Clock Properties Dialog.

Options available for the clock are to show the Second Hand and any Pending Real Time clock events.

Note: The use of the secondhand on the screen demands more processor time and as such it is
really only recommended for testing purposes.

Touch Screen Standard Clock Touch Screen Clock with Second Hand and Pending Events

By clicking on "List Events" the events are displayed on the screen, colours are used to denote the status of the
events.

Page 53 © Philips 2009


Vision Net Designer

 White: Scheduled for today but has not yet executed

 Black: Scheduled for today and has executed today

 Red: Disabled

 Yellow: Not scheduled for today (Day-of-week or exception list)

Note: You can add a Suspend Clock button to a touch screen to enable or disable any events
that are pending on that screen. By using an RTC Group button, you can just disable
certain groups of events, rather than disabling the entire clock.

Page 54 © Philips 2009


Vision Net Designer

Saving the Configuration to the Touch Screen


Once designed the touchscreen configuration can be exported from Vision.net designer. This is done using the
Export button on the touchscreen toolbar.

Touch Screen Toolbar Export Dialogue

Manual Update
Step 1. Select Export from the Touch Screen Toolbar
Step 2. Select "File for touch screen" and select OK
Step 3. Save the “ActiveScreen” into a Folder called "UPDATE" in the root of a USB Memory Stick
Step 4. Place the USB stick with the file into the Touch Screens USB interface and power cycle
the Touch Screen, following the on screen instructions

Note: If you do not create the UPDATE folder and place the ActiveScreen file in this folder it will
NOT be loaded into the screen

Ethernet Export (Old touch Screens running code prior to v2.0.0 code)
Step 1. Connect Vision.net designer to the same ethernet network as the touchscreen
Step 2. Select Export from the Touch Screen Toolbar
Step 3. Select "Ethernet (Legacy)" and select OK

Page 55 © Philips 2009


Vision Net Designer

Ethernet Export (Touch Screens running v2.0.0 code or later)


Step 1. Connect Vision.net designer to the same ethernet network as the touchscreen
Step 2. Select Export from the Touch Screen Toolbar
Step 3. Select "Ethernet"
Step 4. Enter the IP address of the touch screen and select OK

Page 56 © Philips 2009


Vision Net Designer

Output Devices

Concepts
Output devices are devices that connect to the Vision.net Network and drive lights or other controllable
elements.

These are typically the Strand Lighting C21, EC21, R21, S21 and A21 dimmer racks. DMX only devices, such
as LED fittings, Moving Lights etc. may also be controlled using the Vision.net DMX interface card.

Page 57 © Philips 2009


Vision Net Designer

Adding Devices

Adding Output Devices to the Network


Using the Main Tool Bar, click on Add to Network and select Output Device.

As with adding other devices, a dialog box will appear, prompting your for the Devices' ID number, Name, Type
and number of devices.

Device Details Screen


Once the device is entered, a spreadsheet style form for will appear for the output device, allowing details of
each of the circuits to be entered.

Dimmer Output Device Relay Output Device

Page 58 © Philips 2009


Vision Net Designer

DMX Output Device

In the Output Device form, you can select several rows or outputs at once, by clicking and dragging to select
multiple items. Using the Enter Key will duplicate the current value to the selected range and will move down to
the next cell. Pressing Tab will duplicate and move to the next column if more than one column is selected.

When you select a Range of Channels or zones, entering a value and pressing Enter, will result in a Quick Tool
option, allowing you to automatically increment the channel/zone number for that selected range.

Dimmer/Relay/DMX The output address or Logical dimmer number in a C21, EC21,


R21, S21 or A21 rackm or the DMX address of a Vision.net
DMX512 Ouput board.

Description Optional Text entry to identify that circuit.

Group/Room The Group/Room that the channel belongs to.

Channel/Zone The Channel in the Room that that dimmer or DMX address will
respond to.

Non Dim/Dimmer Selects if this is a switching circuit, or one that dims from 0 to
100%.

Priority This is a priority setting, allowing that output channel to be


controlled on one of the following basis:
 Highest Takes Precedence.
 DMX if present, otherwise Architectural
 DMX Only
 Architectural Only

Warn This option determines if this circuit will give a warning flash
when the room it belongs to is swept. See the Sweep Room
Button Action

Tip: You can use Vision.net designer in Design mode, working off line to prepare some

Page 59 © Philips 2009


Vision Net Designer

presets. You can do this by using the Rack and DMX simulation tools (see Simulations).

Once you have recorded your desired states, you can connect your computer to the
Vision.net system using a Vision.net RS232 interface (Part Number 63025). By selecting
the Synchronise tool from the Output Decice toolbar, the settings can be downloaded or
uploaded to/from the real output device.

Synchronising the Data to the Device


If you are synchronising data to C21 or EC21 dimmer racks, the ID of the output device needs to be set to the
System UID of the Dimmer rack.

Note:

DMX B Mode is set to SVN to enable


Vision.net communications to the
dimmer rack.

Enabling SVN Sharing allows the data


to be sent over an ethernet connection
between multiple racks.

System UID. This value needs to be


that same as the Output ID setup in
Vision.net designer

Printing the Data


By selecting the print option, a print preview window will open, allowing you print out the Output Device
configuration.

Page 60 © Philips 2009


Vision Net Designer

Page 61 © Philips 2009


Vision Net Designer

Simulations

Concepts
When designing a Vision.net system, there are times when you would like to visualise what the outputs might
look like. To this end there are two simulation tools provided within Vision.net Designer.

Rack
By selecting the Rack simulation tool, a window mimicking the output levels of the selected output device will be
shown. The Rack simulation can be switched on and off at any time

Note: You must setup an Output device if you wish to use the Rack Simulation tool.

DMX
As well as simulating the output of the system, you can also simulate a DMX control signal coming form a DMX
console. This DMX signal is one that will be used to set the levels on one of your output devices, depending on
the Priority setting of the Output device the simulated DMX level will show on the Rack simulation.

Page 62 © Philips 2009


Vision Net Designer

Palette OS

Overview
A control console running the Strand Lighting Palette OS may be controlled from a Strand Lighting Vision.net
System, allowing sophisticated integration between an Architectural Lighting system and the control console.

To enable this function, the Vision.net interface on Palette OS needs to be enabled. This is done in the
Hardware Setup for the console and by assigning a Variable page to receive information from Vision.net.

Enabling the Vision.net Interface:


The port used for Vision.net is selected in Console Section of the {Hardware Setup} followed by
{Console}

Change the Vision.net port to COM1 as above.

Note: This is a global setting and only needs to be set once, since it is stored
separate from the show file

Linking Vision.net actions to the console:


Events from Vision.net panels appear as Variables inside the console. To make use of these variables, they
need to be patched in and connected to actions inside the console.

Open the Variables Display (Display - Vaiables) and Right Click to add a new Variable Page, by selecting "Add
Variable Page"

Having added the variable page, you can give it an easy to remember name by double clicking on it.

The finalk stage is the Patch Column entry. This is in the form of Bx, where "x" refers to the Vision.net Room
for the Panel. So for example, if the button that we needed to interface to was in Room 5, we would enter B5 in
the patch.

Page 63 © Philips 2009


Vision Net Designer

In the above example, the Variable Page has been assigned the to Room 1. Having created that link, we need
to add a separate variable for each button.

Adding a new Variable is done using the {Add Variable} softkey displayed at the bottom of the screen.

By adding a variable to the page, it is automatically assigned an "Order" and a "Name". In the case of
Vision.net, the Order number is the button number that you want to link to. The name is a name that you can
use within Macros Scripts, to find out the the current value.

When you add variables to a page, they will automatically start at One and increment. You can modify the
"Order" value, just by double clicking. In the above example the Order has been changed to 8 to correspond to
button Number 8 in the patched Room (Room 1 (B1) from this example). It has also been give the name of "VN
Button8" so that we can use this variable inside macros.

The following script example would allow you to findout the current value:

HC.VariableGet('Vision Net','VN Button8')

Assigning a Action to the Variable


Macros are set using the Macro cell for the variable. Double clicking on the Macro cell opens the macro
dialogue box.

Page 64 © Philips 2009


Vision Net Designer

Use OK to close the Macro defination screen.

Testing
Press the Vision.net button and notice the "value" for the corresponding variable goes from zero to one

Page 65 © Philips 2009


Vision Net Designer

Real Time Clock

Concepts
The Real Time Clock section of the software allows events to be cued based on the time of day. Event
scheduling may be done on a daily basis, either at an absolute time, or relative to Sunset and Sunrise.

In order for events to be scheduled, a real time clock has to be present on the Vision.net Network. Vision.net
designer itself can serve as a real time clock, or alternatively a Touch Screen or Contact Relay panel may be
used.

Note: Modification of the Real Time clock is only possible when the system is running in the
Admin Map or All Map mode.

Adding Real Time Clocks to the Network


Using the Main Tool Bar, click on Add to Network and select Real Time Clock. As with adding other devices, a
dialog box will appear.

The Real Time Dialog Box

ID Number
You start by giving the Real Time Clock an ID number to identify it form others that might also be part of your
system. Vision.net Designer will automatically prompt you with the next free ID number.

Choosing the Real Time Running Location


From the list, choose where the real time clock events for this ID will be triggered from. You have three
choices:
 PC - A Vision.net Designer PC
 Touch Screen
 Output Device - for example Contact Relay Panel.

Note: If you are going to run an Real Time clock on an Output Device or Touch Screen, set the
ID number of the Real Time Clock to the same ID of the Device you wish to use to run it
on.

Page 66 © Philips 2009


Vision Net Designer

Timed Events

Timed Events
You Add, Delete or Edit timed events using the Timed Events Toolbar.

Time Events Toolbar

Add
The add button opens up the event dialogue box for configuring and scheduling events. Events can be
scheduled on a daily basis at an absolute time or a time relative to Sunrise and Sunset.

Event Modification Dialogue Box

Each event can be assigned a group number. Groups on the real time clock can then be Enabled or Disabled
by Smart buttons or Clock Actions.

Events are added and tested using the Edit Action List and Test Action List Buttons

Page 67 © Philips 2009


Vision Net Designer

Event Action Setting

Edit
This button allows you to edit the selected event.

Delete
Deletes the selected event.

Location
The location dialogue box, set the Latitude and Longitude of the site, thereby calculating Sunrise and Sunset
timing. A location can be looked up using the Lookup button.

Location Dialogue Box

Icon View
Switches the display between an Event Schedule list or an Icon display of Events.

Page 68 © Philips 2009


Vision Net Designer

Export
Available on Touch Screens and Output Devices. This button downloads the event settings to the Touch
Screen or Output Device with the same ID as the Real Time Clock setting.

The export operation can take place over Vision.net Network in the case of an Output Devices or an Ethernet
Network Connection or Configuration File in the case of a Touch Screen.

Event Export Dialogue Box for a Output Event Export Dialogue Box for a Touch
Device Screen

Set Remote Clock


Available only for Output Devices, this button allows you to set the time on the Output Device.

Remote Clock Dialogue Box

Page 69 © Philips 2009


Vision Net Designer

Page 70 © Philips 2009


Vision Net Designer

Page 71 © Philips 2009


Vision Net Designer

Push Button Stations


PCB 70-1693 Rev A

J1 – Vision.net

1 Data + White/Orange

2 Data - Orange

3 SCREEN

4 +24v White/Green

5 GND Green

6 +24v White/Blue

7 GND Blue

8 +24v White/Brown

9 GND Brown

Page 72 © Philips 2009


Vision Net Designer

DMX Interface Stations


PCB 70-1678 Rev B

J5 + J6 Vision.net

1 Data + White/Orange

2 Data - Orange

3 SCREEN

4 +24v White/Green

5 GND Green

6 +24v White/Blue

7 GND Blue

8 +24v White/Brown

9 GND Brown

J1 – DMX In

1 Screen

2 Data -

3 Data +

4 NC

5 NC

J2 – DMX Out

1 Screen

2 Data -

3 Data +

Page 73 © Philips 2009


Vision Net Designer

4 NC

5 NC

J4 – Power (12v -24v)

Pin +V
Hole

Barrel GND

Page 74 © Philips 2009


Vision Net Designer

Fader Stations
PCB 70-1700 Rev B

J3 - Vision.net

1 Data + White/Orange

2 Data - Orange

3 SCREEN

4 +24v White/Green

5 GND Green

6 +24v White/Blue

7 GND Blue

8 +24v White/Brown

9 GND Brown

Page 75 © Philips 2009


Vision Net Designer

RS232 Station

Vision.net

1 Data + White/Orange

2 Data - Orange

3 SCREEN

4 +24v White/Green

5 GND Green

6 +24v White/Blue

7 GND Blue

8 +24v White/Brown

9 GND Brown

Serial Port
Serial Ports Female 9 pin D-type

Pin Description

Pin 1 Data carrier detect

Pin 2 Receive data

Pin 3 Transmit data

Pin 4 Data terminal ready

Pin 5 Ground

Pin 6 Data set ready

Pin 7 Request to send

Pin 8 Clear to send

Page 76 © Philips 2009


Vision Net Designer

Pin 9 Ring indicator

General purpose RS232, baud rates 9600

Page 77 © Philips 2009


Vision Net Designer

Palette

Serial Port Male 9 pin D-type

1 Data carrier detect

2 Receive data

3 Transmit data

4 Data terminal ready

5 Ground

6 Data set ready

7 Request to send

8 Clear to send

9 Ring indicator

General purpose RS232, baud rates 1200 to 38400

Page 78 © Philips 2009


Vision Net Designer

Portable Stations and Screens


Receptacle Station

Female 6 pin XLR

1 Ground Green, Blue, Brown

2 +24V White/Green, White/Blue,


White/Brown

3 Data - Orange

4 Data + White/Orange

5 TS VCommon

6 TS V+

Portable Station

Male 6 pin XLR

1 Ground

2 +24V

3 Data -

4 Data +

5 TS VCommon

6 TS V+

Page 79 © Philips 2009


Vision Net Designer

Page 80 © Philips 2009


Vision Net Designer

Button and Event Actions

Table of Button/Event Settings

Preset If the action is set as a Preset it will allow you to set which room and which
preset the button selects. It will also allow you to set a fade time for the
preset. A preset selection button also has the option to disable the Press
and Hold Learn feature for the button

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

Preset On/Off If the action is set as a Preset On/Off the Button becomes a latching
button, switching the selected preset on and off.

Applies to Touch Screens, Smart Buttons and Button Stations

Toggle The toggle action will allow you to switch a channel belonging to a group
on and off with each press. You specify the ID of the Group the channel
belongs to and the number of the channel.

Tip: To toggle more than one circuit at the same time,


you can either use the Preset On/Off button or a
Smart Button as a latching button with a Toggle On
action on the Button Down action and Toggle Off
action on the Button Up action.

Using Smart buttons like this, you can add a wait


time between each circuit switching On/Off thereby
obtaining a sequenced switch on/off of the circuits.

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

Smart As a Smart Button, you can fully customise the action of the button and the
Edit button allows you to set the button action. Smart buttons can be
either latching momentary action switches, with actions assigned to either
the “Button Down” action (when the button is pressed) or the “Button Up”
action (when the button is released).

The default action is placed on the Button Up Action.

Tip: Set the button to be a Latching button rather then


the default Momentary action, when you are using
different actions for the Button Down and Button Up

Note: So as to avoid conflicts, a Smart Button’s


commands are only sent by Panels or Touch
screens, or on a virtual Touch Screen on a Vision.
net Designer PC.

Page 81 © Philips 2009


Vision Net Designer

When using the Mimic style on Vision.net Designer,


selecting a smart button on a mimicked touch
screen will still send the button Up/Down action,
thereby triggering the real device to send the smart
button commands.

Applies to Touch Screens, Smart Buttons and Button Stations

Lock Button The Lock button action allows you select the a button on a particular panel
to be lock thereby preventing it from being pressed by a user. This can be
handy for buttons in public areas, allowing them to only to be available at
certain times of day.

With the Button selection, you can select either all buttons or a just a
single button. Under Panel ID you enter the Number of the Panel you want
the button(s) to be locked.

Note: To lock multiple buttons use multiple lock actions on


a Smart button

Applies to Smart Buttons and Timed Events

Unlock Button Unlocking buttons allows you to select the button and the panel that you
wish to allow to unlock.

With the Button selection, you can select either all buttons or a just a
single button.

Under Panel ID you enter the Number of the Panel you want the button(s)
to be unlocked.

Note: To lock multiple buttons use multiple lock actions on


a Smart button

Applies to Smart Buttons and Timed Events

Wait This function is a program flow control and allows you considerable control
over what the button does.

A wait allows you to put a pause in the actions of the smart button. Handy
for example if you want a button to Switch On a circuit and then a few
moments later to switch on another.

Applies to Smart Buttons

Loop This function is a program flow control and allows you considerable control
over what the button does.

Page 82 © Philips 2009


Vision Net Designer

The Loop action allows you to loop to a specific action. A count allows you
to specify the number of time that it will go through that loop.

Applies to Smart Buttons

Smart On This function allows you control other smart buttons on panels and switch
them on remotely.

Applies to Smart Buttons and Timed Events

Smart Off This function allows you control other smart buttons on panels and switch
them off remotely.

Applies to Smart Buttons and Timed Events

Raise A button configured as a Raise Button allows you to either Raise


Channels, a defined Preset or the currently selected Preset

Applies to Touch Screens and Button Stations

Lower A button configured as a Lower Button allows you to either lower


Channels, a defined Preset or the currently selected Preset.

Applies to Touch Screens and Button Stations

Genlyte Scene This function allows you control a Genlyte Controls ILS station connected
on the same network and select one of its presets.

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

Console Button This function allows you to trigger events on a Strand Lighting Palette,
Light Palette or Rack Palette lighting control console.

For more detail on the setup for this see: Palette OS

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

Smart Mimic This allows this button to mimic the state of a button on a Touch Screen in
the network.

Applies to Touch Screens and Button Stations

Room Link This allows the button to act a Room Combine function, joining two Groups
or Rooms together.

Applies to Touch Screens and Button Stations

No Button On a button station, this option removes the button for configuration
purposes.

Page 83 © Philips 2009


Vision Net Designer

Applies to Button Stations

Select Mode This allows the button to select one of the 9 differnt modes of system
operation.

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

Share Button This allows a shared Shared Button on a Touch screen to be remotely
pressed.

Buttons that can be shared are PSSLS, Room Link, Smart Buttons, Tabs
and Toggle Master buttons on a Touch Screen. Buttons on a Touch
Screen as shared and given a name to identify it.

Applies to Touch Screens, Smart Buttons, Timed Events and Button


Stations

RTC Group Used in Smart buttons to enable or disable Real Time Clock Group Events

Applies to Smart Buttons and Timed Events

Toggle Master Toggle Masters allow Toggle Buttons Groups to be learned. This can be
very useful when using Toggle Buttons for Non-Dims on a Stage Lighting
system.

Toggle Masters may be set to Perform in one of three ways:

1) Alternate Action where the Button alternately turns On and Off the
selected Toggle Buttons

2) Toggle On where the Button turns On the selected Toggle Buttons

3) Toggle Off where the Button turns Off the selected Toggle Buttons

Applies to Touch Screens

Suspend Clock Having a Toggle Action, when active, this button suspends any pending
Real Time Clock events on the designated clock controller.

Applies to Touch Screens,

Set Clock This button opens up the Clock dialog option of a touch screen.

Applies to Touch Screens,

CK Show This button type will trigger a Philips ColorKinetics Show state. The
connection for the Philips ColorKinetics Show is configured in the Touch
Screen Properties Dialogue

Applies to Touch Screens,

Sweep Room This Action will "Sweep Up" the lights in a room, placing the room in

Page 84 © Philips 2009


Vision Net Designer

darkness. The sweep action has two parameters, Warn and Shutoff
times.

When the Sweep action takes place, the lights in the designated room will
briefly flash to warn you that they will change, provided the "warn" option is
selected for that circuit on the Ouput Device.

After the warn time, Preset 0 for that room will be selected.

If a new preset is selected after the warning, that preset will remain active
for the Shutoff time.

Example:

Sweep is set for 11:00PM

Warn is 5
Shutoff is 60

11:00 pm Warning
11:05 PM Off

A preset is pressed at 11:30

12:30 AM Warning
12:35 AM Off

The sweep will remain active until an End Sweep Room event is activated.

Note: A Sweep Action will not clear any toggle buttons that
are currently on but will switch off those circuits.
Consequentially you should not have any toggle
controllers in a room that will be swept.

Applies to Timed Events

End Sweep Room The End Sweep Room event cancels the Sweep Room Action.

Applies to Timed Events

Page 85 © Philips 2009


Vision Net Designer

Smart Buttons

Smart Buttons
Smart buttons are one of the most powerful features of VisionNet, allowing a number of actions to be combined
on the press of a single button.

These buttons have two actions, one while the button is held down and the other when the button is released.
Additionally, smart buttons can be configured t have either a momentary or toggle action.

Note: Since Button Down actions only take place when the button is held down, it is often best
practice; when using a momentary action on a smart button, to put all the actions in the
Button Up list. By doing this, it removes the need for the user to hold the button down
until all the events have processed.

Conversely, this can also be used to your advantage. If by introducing a Wait action on a
key, you can ensure that an action on it takes place, only if a user "Holds" the button
down for the duration of the Wait time.

Example

Smart Button Properties Dialog.

Using the Smart Button Dialog boxes, you can create sophisticated events. The above example shows a
example of a button which will perform as follows:

1. When the button is held down, it will trigger Preset 1 in Room/Group 2.

2. When the button is released, it will run Preset 1 in Room/Group 1, wait for an hour and then Run
Preset 2 in Room/Group 1 continually cycling round 5 presets. This for example could be used to
change colours on a set of LED devices cycling round a sequence of colours.

Page 86 © Philips 2009


Vision Net Designer

Touch Screen Maintenance

Maintenance Mode
A special Maintenance Mode is provided for Touch Screens. In this mode, you can bring up settings on the
touchscreen, allowing them to be changed.

To enable the Maintenance Mode, hold down the Control key and select the desired touch screen from the My
Network Tree. If you are currently viwing the touchscreen you wish to maintain, then first select another item
from the Network Tree. A password prompt will appear. Enter the Password and a new toolbar option will be
available.

Select Maintenance and the following dialogue box will appear

Select the required Option and follow the on screen instructions.

Page 87 © Philips 2009


Vision Net Designer

Trouble Shooting

In order to determine if a Vision.net Network device is communicating, a network test signal can be sent to
devices on the network, using the Vision.net Designer software . To do this, the Flash Station signal is sent to
the station in order to verify communications.

Station Identification:
Step 1. Connect the PC running the Vision.net Designer software to the Vision.net Network via
the Vision.netRS232 station, using an RS232 lead. Alternatively you can connect to the
Vision.net network using a Bluetooth interface. Please contact your local Strand Lighting
Office for more details on this interface.
Step 2: Set Vision.net Designer to work “On Line”.
Step 3: Select the required panel from the Network Tree and press the Station ID button.
Step 4: Select Flash Station and the LED Indicators of the selected station will flash.

Using the Flash Station tool to troubleshoot.

Page 88 © Philips 2009


Vision Net Designer

Offices and Service Centres

Strand Lighting Asia,


20/F Delta House, 3 On Yiu Street, Shatin, N.T. Hong Kong
Tel: + 852 2757 3033 Fax: + 852 2757 1767

Strand Lighting Europe Ltd,


Unit 2 Royce Road, Fleming Way, Crawley, West Sussex. United Kingdom
Tel: + 44 1293 554010 Fax: + 44 1293 554019

Strand Lighting Inc,


6603 Darin Way, Cypress, CA 90630, USA
Tel: +1 714 230 8200 Fax: +1 714 230 8173

The material in this manual is for information purposes only and is subject to change without notice. Strand
Lighting assumes no responsibility for any errors or omissions which may appear in this manual. For comments
and suggestions regarding corrections and/or updates to this manual, please contact your nearest Strand
Lighting office.

El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso. Strand
Lighting no asume responsabilidad por errores o omisiones que puedan aparecer. Cualquier comentario,
sugerencia o corrección con respecto a este manual, favor de dirijirlo a la oficina de Strand Lighting más
cercana.

Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht, Aenderungen sind vorbehalten. Strand
Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer, die in diesem Handbuch auftreten. Für
Bemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und/oder
Aktualisierungen in diesem Handbuch, moechten wir Sie bitten, Kontakt mit der naechsten Strand Lighting-
Niederlassung aufzunehmen.

Le matériel décrit dans ce manuel est pour information seulement et est sujet à changements sans préavis. La
compagnie Strand Lighting n'assume aucune responsabilité sur toute erreur ou omission inscrite dans ce
manuel. Pour tous commentaires ou suggestions concernant des corrections et/ou les mises à jour de ce
manuel, veuillez s'll vous plait contacter le bureau de Strand Lighting le plus proche.

Information contained in this document may not be duplicated in full or in part by any person without prior written
approval of Strand Lighting Inc. Its sole purpose is to provide the user with conceptual information on the
equipment mentioned. The use of this document for all other purposes is specifically prohibited. Certain
features of the equipment described in this document may form the subject of patents or patent applications.

Page 89 © Philips 2009


Vision Net Designer

Index
-A-
Adding Devices 58

-B-
Button and Event Actions 81
Button Stations 72
Buttons 31

-C-
Communications 9
Control Stations 30
Custom Panels 38

-D-
DMX Interface 73

-F-
Fader Stations 75
File 12

-G-
Group/Rooms 29

-H-
Help 22

-L-
Loading from a Station 37
Loading Touchscreen 55

-M-
Main Tool Bar 24
Maps: Display/Unlock All 22
Mode Maps 19

-O-
Offices and Service Centres 89
Operating Style 18
Output Devices 57

-P-
Palette 78
Portable Stations and Screens 79

Page 90 © Philips 2009


Vision Net Designer

-R-
Real Time Clock 66, 21
RS232 Station 76

-S-
Saving and Loading Station Configurations 35
Saving to a Station 36
Screen Design 43
Setup 15
Simulations 62
Slider Faders 33
Smart Buttons 86
Station ID 34
Status Bar 27

-T-
Timed Events 67
Tools 14
Touch Screen Buttons 47
Touch Screen Maintenance 87
Touch Screen Raise and Lower 51
Touch Screen Slider 48
Touch Screen Slider Panels 50
Touch Screen Tabbed Views 44
Touch Screen Text 52
Touch Screen Tool Bar 41
Touch Screens 39
Trouble Shooting 88

-V-
Vision.Net Designer Software
Vision.Net Overview 8

-W-
Welcome , 6
Welcome , 6

Page 91 © Philips 2009


Vision Net Designer

Page 92 © Philips 2009


Strand Lighting Europe Limited,
Unit 2 Royce Road,
Fleming Way,
Crawley,
West Sussex.
United Kingdom.
RH10 9JY
Tel: + 44 1293 554 010
Fax: + 44 1293 554 019

Strand Lighting Asia,


20/F Delta House,
3 On Yiu Street,
Shatin,
N.T. Hong Kong
Tel: + 852 2757 3033
Fax: + 852 2757 1767

Strand Lighting Inc,


6603 Darin Way,
Cypress,
CA 90630,
USA
Tel: +1 714 230 8200
Fax: +1 714 230 8173

© 2009 Philips Group.


All Rights Reserved.

Anda mungkin juga menyukai