Anda di halaman 1dari 1

SPEC 1050

March, 2012

CHTC

XLPE/XL-CPE, Instrumentation, Shielded


300 V, UL Type PLTC, Overall Shielded Pairs/Triads
Product Construction:
Conductor:

20 AWG thru 16 AWG tinned, annealed copper per


ASTM B33
Class B stranding per ASTM B8

Insulation:

CATALOG
NUMBER

COPPER
MINIMUM AVG. MINIMUM AVG.
WEIGHT
NET WEIGHT
INSULATION
JACKET
NOMINAL
NO. OF COND.
THICKNESS
THICKNESS
CABLE
O.D.
PAIRS/ SIZE COND.
LBS/
LBS/
TRIADS (AWG) STRAND INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km

1
1 TRI
2
4
8
12
16
20
24
36
50

20
20
20
20
20
20
20
20
20
20
20

7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121
7/.0121

0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012
0.012

0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.30

0.035
0.035
0.040
0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070

0.89
0.89
1.02
1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78

0.230
0.240
0.320
0.370
0.500
0.575
0.665
0.740
0.795
1.005
1.175

5.84
6.10
8.13
9.40
12.70
14.61
16.89
18.80
20.19
25.53
29.85

9
13
17
31
60
89
118
148
177
264
365

14
19
25
47
90
133
176
220
263
392
544

27
33
48
73
138
186
248
300
350
525
697

40
49
71
109
205
277
369
446
521
781
1037

OVERALL SHIELDED PAIRS/TRIADS


18 AWG CONDUCTORS
337820*
337830*
337840*
337850*
337860*
337870*
337880*
337890*
337900*
337910*
337920*

1
1 TRI
2
4
8
12
16
20
24
36
50

18
18
18
18
18
18
18
18
18
18
18

7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152
7/.0152

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.035
0.040
0.050
0.050
0.060
0.060
0.060
0.070
0.070
0.070

0.89
0.89
1.02
1.27
1.27
1.52
1.52
1.52
1.78
1.78
1.78

0.245
0.255
0.350
0.425
0.545
0.640
0.730
0.810
0.895
1.095
1.255

6.22
6.48
8.89
10.80
13.84
16.26
18.54
20.57
22.73
27.81
31.88

16
16
16
16
16
16
16
16
16
16
16

7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192
7/.0192

0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015
0.015

0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38
0.38

0.035
0.035
0.050
0.050
0.060
0.060
0.060
0.060
0.070
0.070
0.080

0.89
0.89
1.27
1.27
1.52
1.52
1.52
1.52
1.78
1.78
2.03

0.270
0.285
0.430
0.490
0.650
0.755
0.845
0.900
1.020
1.225
1.415

6.86
7.24
10.92
12.45
16.51
19.18
21.46
22.86
25.91
31.12
35.94

Overall shielded pairs/triads


Overall shield is Flexfoil aluminum/polymer in
contact with stranded tinned copper drain wire
Lead-free Cross-linked Chlorinated Polyethylene
(XL-CPE)

Print:

GENERAL CABLE (PLANT OF MFG) CHTC XX/


PS/TS XXAWG CU/XLP/XL-CPE SHIELDED (UL)
TYPE PLTC 90C SUN RES OIL RES I & II PLUS
DAY/MONTH/YEAR OF MFG SEQUENTIAL
FOOTAGE MARK

Options:

Bare copper conductor


Class C stranding
Individual and overall shielded pairs/triads
Thermoplastic Low-Smoke, Zero-Halogen (LSZH)
jacket
In accordance with UL Subject 2250 as
Instrumentation Tray Cable (ITC)
Other constructions available upon request

Applications:
13
18
23
44
86
127
169
210
252
377
523

19
26
34
65
127
189
251
313
375
561
778

32
40
58
99
173
245
318
392
450
672
904

48
60
86
147
257
365
473
583
670
1000
1345

18
27
36
69
135
202
268
335
401
601
834

28
41
61
40
54
80
53
85
126
102 135 201
201 246 366
300 346 515
399 444 661
498 552 821
597 655 975
894 649 966
1241 1308 1947

OVERALL SHIELDED PAIRS/TRIADS


16 AWG CONDUCTORS
1
309520*
337930* 1 TRI
2
337940*
4
337950*
8
337960*
12
337970*
16
337980*
20
337990*
24
338000*
36
338010*
338020* 50

Shield:

Jacket:

OVERALL SHIELDED PAIRS/TRIADS


20 AWG CONDUCTORS
337770*
337780*
337790*
309660*
309670*
309680*
337800*
337810*
309690*
311640*
309700*

Flame-retardant Cross-linked Polyethylene (XLPE)


Color-coded per ICEA Method 1: Pairs - black
and white; Triads - black, white and red. One
conductor in each pair or triad is printed alphanumerically for easy identification

Dimensions and weights are nominal; subject to industry tolerances.


* Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.

Typical applications include audio, intercom,


control, energy management and alarm circuits
In free air or raceways in accordance with NEC
Permitted for use in Class I, Division 2 industrial
hazardous locations per NEC
In ducts, cable trays or conduit
In accordance with UL Subject 13 as PowerLimited Circuit Cable
In class 3 circuits in accordance with NEC

Features:

Rated at 90C
Ripcord applied to all cables with jacket thickness
of 60 mils or less
Oil-resistant jacket
Sunlight- and weather-resistant
Excellent electrical, thermal and physical
properties
Excellent moisture resistance
Excellent flame resistance
Heavy duty rating per ICEA standards
Excellent low temperature cold bend
characteristics
Meets cold bend test at -35C

Compliances:

Industry Compliances:
UL 13 Type PLTC, UL File # E36118
UL 1581
Flame Test Compliances:
UL 1581/UL 2556 VW-1
IEEE 383
IEEE 1202
CSA FT4
Other Compliances:
EPA 40 CFR, Part 261 for leachable lead
content per TCLP
OSHA Acceptable

Packaging:

Material cut to length and shipped on


non-returnable wood reels

Phone: 888-593-3355