ndice
ABB
Baja Tensin
2/1
1TXA0CC001D0703
Las corrientes a continuacin indicadas corresponden a motores trifsicos estndar con rotor en jaula de ardilla de 1 500 r.p.m., 50 Hz.
Estos valores se indican slo a ttulo informativo, pudiendo variar en funcin del fabricante del motor y de su nmero de polos.
Potencia motor
kW
380 V
380-400 V
A
CV
415 V
440 V
500 V
600 V
660-690 V
0.06
0.09
0.12
0.18
0.25
1/12
1/8
1/6
1/4
1/3
0.22
0.33
0.42
0.64
0.88
0.20
0.30
0.40
0.60
0.85
0.19
0.28
0.37
0.55
0.76
0.16
0.24
0.33
0.46
0.59
0.12
0.21
0.27
0.40
0.56
0.37
0.55
0.75
1.1
1.5
1/2
3/4
1
1.5
2
1.22
1.50
2.00
2.60
3.50
1.15
1.40
2.00
2.50
3.50
1.06
1.25
1.67
2.26
3.03
0.85
1.20
1.48
2.10
2.60
0.77
1.02
1.22
1.66
2.22
0.7
0.9
1.1
1.5
2.0
4.31
4.90
5.80
7.10
7.60
3.8
4.3
5.1
6.2
6.5
3.16
3.59
4.25
5.20
5.60
2.9
3.3
3.5
4.4
4.9
2.2
2.5
3
3.7
4
3
3.4
4
5
5.5
5.0
5.7
6.6
8.2
8.5
5.0
5.5
6.5
7.5
8.4
5
5.5
6.5
7.5
8
6.8
7.5
8.8
10
11
10.5
11.5
13.8
15.5
16.7
10.0
11.0
12.5
14.0
15.4
9.4
10.3
12.0
13.5
14.4
8.1
8.9
10.4
11.9
12.7
6.9
7.5
8.7
9.9
10.6
6.0
6.7
8.1
9.0
9.7
9
11
12.5
15
18.5
12.5
15
17
20
25
18.3
22.0
25.0
30.0
37.0
17
21
23
28
35
15.8
19.3
21.9
26.3
32.0
13.9
16.7
19.0
22.5
28.5
11.6
14.1
16.1
19.3
23.5
10.6
13.0
15.0
17.5
21.0
20
22
25
30
37
27
30
34
40
50
40
44
50
60
72
37
40
47
55
66
34.6
37.1
42.1
50.1
61.9
30.6
33.0
38.0
44.0
54.0
25.4
27.2
30.9
37.1
45.4
23
25
28
33
42
40
45
51
55
59
54
60
70
75
80
79
85
97
105
112
72
80
90
96
105
67.0
73.9
83.8
90.3
96.9
60.0
64.5
73.7
79.0
85.3
49.1
54.2
61.4
66.2
71.1
44
49
56
60
66
75
80
90
100
110
100
110
125
136
150
140
147
170
188
205
135
138
165
182
200
123
131
146
162
178
106
112
128
143
156
90.3
96.3
107.0
119.0
131.0
82
86
98
107
118
129
132
140
147
160
175
180
190
200
220
242
245
260
273
295
230
242
250
260
280
209
214
227
236
256
184
186
200
207
220
153
157
167
173
188
135
140
145
152
170
2/2
1TXA0CC001D0703
ABB
Baja Tensin
Arrancadores en caja
Panorama
Proteccin
mediante rel
trmico de
sobrecarga
DYA
YRA
Motor trifsico
WRA
1 sentido de marcha
Arranque
2 sentidos de marcha
Directo
Estrella-tringulo
Directo
Corriente asignada
de empleo (400 V)
37 A AC-3
30 A AC-3
37 A AC-3
Potencia asignada
de empleo
18.5 kW
15 kW
18.5 kW
YRA
WRA
Tipo arrancador
Rel trmico
Proteccin
mediante
guardamotor
asociado
YRA DB
DRA D
Motor trifsico
Arranque
WRA DB+BU
1 sentido de marcha
Directo
2 sentidos de marcha
Estrella-tringulo
Corriente asignada de
empleo (400 V)
25 A AC-3
Potencia asignada de
empleo
11 kW
Tipo de arrancador
Tipo de arranque
ABB
Baja Tensin
Directo
2/3
1TXA0CC001D0703
2/4
1TXA0CC001D0703
ABB
Baja Tensin
Arranque estrella-tringulo de
motores asncronos trifsicos
Generalidades
En el arranque, el motor debe vencer el par resistente y la inercia de la mquina accionada. Durante esta fase, la corriente debe
mantenerse dentro de los lmites aceptables para la red.
La inercia, el par resistente y las caractersticas de la red son datos habitualmente constantes.
Aunque el tipo de arranque reduce la corriente de pico, tambin reduce el par entregado por el motor. El resultado es que el tiempo de aceleracin
vara en funcin del tipo de arranque empleado.
Arranque estrella-tringulo
Datos tcnicos
En el arranque:
la corriente de arranque se reduce a un tercio de la corriente de arranque
directo.
el par motor se reduce a un tercio del par de arranque directo.
Durante la conmutacin estrella-tringulo se suelen registrar puntas de
intensidad elevadas.
Aplicacin
Durante la fase inicial de arranque (conexin en "estrella"), el par resistente
de la mquina accionada debe permanecer constante, independientemente
de su velocidad, inferior al par motor de la conexin "estrella" hasta que se
produzca la conmutacin "estrella-tringulo".
Por tanto, este modo de arranque resulta ideal para mquinas con
arranque en vaco y baja inercia:
mquinas-herramienta,
compresores centrfugos,
mquinas de trabajo de la madera, etc.
Para impedir un pico de corriente excesivamente alto, al efectuar la
conmutacin "estrella-tringulo" debe haberse alcanzado al menos
el 80% de la velocidad nominal.
Precauciones
La tensin nominal del motor en la conexin tringulo debe ser igual a la
de la red.
Ejemplo:
En la conexin "tringulo" debe especificarse un motor para arranque en
estrella-tringulo a 380 V. Su denominacin habitual es "motor 380 V/660
V". El motor debe estar construido con devanados de 6 bornes.
Funcionamiento
El arranque se desarrolla en un proceso de tres etapas:
1 Etapa - Conexin "Estrella"
Accione el pulsador "On" del circuito de mando para cerrar el contactor "estrella" KM2 . A continuacin se cierra el contactor de "red" KM1 y el motor
arranca. Acto seguido, comienza la cuenta atrs del tiempo de arranque programado (normalmente 6 hasta 10 s).
2 Etapa - Conmutacin de "Estrella" a "Tringulo"
Una vez transcurrido el tiempo de arranque programado, se abre el contactor "estrella" KM2.
3 Etapa - Conexin en "Tringulo"
Despus de haber transcurrido 50 ms, se cierra el contactor "triangulo" KM3 , y el motor acelera hasta que alcanza la velocidad nominal.
Nota: el perodo de 50 ms que transcurre entre la apertura del contactor "estrella" y el cierre del contactor "tringulo" impide la formacin de cortocircuitos con arcos.
ABB
Baja Tensin
2/5
1TXA0CC001D0703
SB7454C0
Indicar tensin
cdigo
mando:
tensin mando:
Peso
kg
Embal.
1 ud
DWA 9-30
0.810
12
17
12
17
1
1
DWA 12-30
DWA 16-30
0.810
0.810
Envolvente 9
IP 65
12
17
9
12
17
1
1
1
DYA 9-30
DYA 12-30
DYA 16-30
0.810
0.810
0.810
Envolvente 9
IP 43
DWA 9-30
Tipo
(1) Pedir por separado el rel trmico de sobrecarga, vase detalles para pedido en pgina 2/7.
Cdigo
Circuito de mando
E0710D
Tensin
(V) 50 Hz
2/6
1TXA0CC001D0703
ABB
Baja Tensin
Envolvente
SB7454C0
IP 43
Envolvente
IP 65
DYA 9-30
Corriente
asignada
empleo AC-3
380 V
400 V 415 V
A
A
Contactos
aux.
montados
9
12
17
9
12
17
1
1
1
9
12
17
9
12
17
1
1
1
Tipo
Embal. Peso
Indicar tensin
Cdigo
mando:
tensin mando:
uds.
kg
DWA 9-30
DWA 12-30
DWA 16-30
1
1
1
0.850
0.850
0.850
DYA 9-30
DYA 12-30
DYA 16-30
1
1
1
0.855
0.855
0.855
(1) Pedir por separado el rel trmico de sobrecarga, vase tabla inferior. (2) Ver tabla de tensiones abajo.
Regulacin
Tipo
Cdigo de pedido
0.1
0.16
0.25
0.4
0.63
1.0
1.3
1.7
2.2
2.8
3.5
4.5
6.0
7.5
10.0
13.0
SB7376C1
TA 25 DU
CA 5-10
0.16
0.25
0.4
0.63
1.0
1.4
1.8
2.4
3.1
4.0
5.0
6.5
8.5
11.0
14.0
19.0
TA 25 DU 0.16
TA 25 DU 0.25
TA 25 DU 0.4
TA 25 DU 0.63
TA 25 DU 1.0
TA 25 DU 1.4
TA 25 DU 1.8
TA 25 DU 2.4
TA 25 DU 3.1
TA 25 DU 4.0
TA 25 DU 5.0
TA 25 DU 6.5
TA 25 DU 8.5
TA 25 DU 11
TA 25 DU 14
TA 25 DU 19
Embal. Peso
uds.
kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
0.150
SB7454C0
CB 5-10
SB7585C2
SB7571C3
FW 16-12 VARS
LP 16
Descripcin
Tipo
CA 5-10
CA 5-01
FPCM 14 P
FI 01-A
BD 7
FN 7-02
Cdigo de pedido
Embal. Peso
uds.
kg
10
10
3
3
10
1
0.014
0.014
0.015
0.002
0.003
0.005
Tipo
Cdigo de pedido
Embal. Peso
uds.
kg
Caja vaca, IP 43
0.495
0.500
CB 5-10
LP 16
1
10
0.012
0.002
24
48
110
Cdigo tensin
bobina :
1
Caja vaca, IP 65
con pulsadores arranque y parada/reset
Contacto "Arranque"
Puente de conexin
ABB
Baja Tensin
2/7
1TXA0CC001D0703
SB8002C3
Indicar tensin
aM
A
gG
A
de mando
de mando
26
32
37
25
32
40
50
63
80
DRA 26-30
DRA 30-30
DRA 40-30
11
15
18.5
15
18.5
22
Fusibles *
Tipo
Cdigo de pedido
Peso
en
kg
Embal.
1 ud.
00
00
00
2.450
2.560
2.560
* Para otros dispositivos de proteccin contra cortocircuitos, por favor consulte nuestras tablas de coordinacin.
Tensin
(V) 50 Hz
(V) 60 Hz
Cdigo
Circuito mando
E1365D
Caja plstico, UL 94 V2
Doble aislamiento, Proteccin IP 64
2/8
1TXA0CC001D0703
ABB
Baja Tensin
SB7386C2
Tipo
arrancador
TA 25 DU
Rango regulacin
Tipo
Cdigo de pedido
Emb. Peso
en
... A
DRA 26-30
y
DRA 30-30
13
18
24
... 19
... 25
... 32
TA 25 DU 19
TA 25 DU 25
TA 25 DU 32
uds.
1
1
1
0.150
0.150
0.170
DRA 40-30
18
22
29
... 25
... 32
... 42
TA 42 DU 25
TA 42 DU 32
TA 42 DU 42
1
1
1
0.330
0.330
0.330
kg
Accesorios
Tipo
BA5-50
caja
0.017
CA5-10
10
0.014
CA5-01
10
0.014
0.050
CB5-10
0.012
CB5-01
0.012
LP 25
10
0.004
SB7361S3
Cdigo de pedido
SB7587C4
TA 42 DU
BA5-50
Emb. Peso
en
uds. kg
Descripcin
SB7603C2
SB7375C4
CB5-10
Tipo
Prensaestopas Pg 16 / CM14P
FPCM 14P
0.013
Prensaestopas Pg 21 / CM18P
FPCM 18P
0.015
CAL 5-11
SB7584C2
SB7571C3
CA5-10
LP25
ABB
Baja Tensin
Cdigo de pedido
Emb. Peso
en
uds. kg
Descripcin
2/9
1TXA0CC001D0703
Coordinacin
Iq = 50 kA
SB8001C3
380-400-415 V
kW ... kW
2.2
3.0
5.0
6.5
...
...
...
...
Emb.
Tipo
Indicar tensin
mando
Aadir cdigo
tensin mando
DRA 9-30-D6.3
DRA 9-30-D9.0
DRA 12-30-D12.5
DRA 16-30-D16
44
45
46
47
1
1
1
1
2.620
2.620
2.620
2.620
DRA 26-30-D20
DRA 26-30-D25
48
49
1
1
2.880
2.880
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
11.0
2
2
Cdigo de pedido
Peso
en
Regulacin
uds.
kg
DRA 9-30 D
(V) 60 Hz
Cdigo
Circuito mando
debe conectarse al circuito
de potencia bien entre fase y fase
o entre fase y neutro (1).
(1) Proporcionar un bloque de contacto auxiliar HK20 para interrupcin del neutro (vase pgina 2/11)
E1368D
2/10
1TXA0CC001D0703
ABB
Baja Tensin
Coordi- Regulacin
nacin
Iq=50kA
SB8001C3
380-400-415 V
kW ... kW
DRA 16-30 DB
2.2
3.0
5.0
6.5
...
...
...
...
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
11.0
2
2
Tipo
Cdigo de pedido
Emb. Peso
en
Indicar tensin
de mando
Aadir cdigo
tensin mando
DRA 9-30-DB6.3
DRA 9-30-DB9.0
DRA 12-30-DB12.5
DRA 16-30-DB16
44
45
46
47
1
1
1
1
2.620
2.620
2.620
2.620
DRA 26-30-DB20
DRA 26-30-DB25
48
49
1
1
2.880
2.880
uds. kg
(V) 60 Hz
Cdigo
Circuito mando
SB8005C3
motor 4 polos
50/60 Hz
DRA 26-30 DB + BU
Coordi- Regulacin
nacin
Iq=50kA
380-400-415 V
kW ... kW
2.2
3.0
5.0
6.5
...
...
...
...
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
11.0
2
2
Tipo
Emb. Peso
en
Cdigo de pedido
Indicar tensin
de mando
Aadir cdigo
tensin mando
DRA 9-30-DB6.3+BU
DRA 9-30-DB9.0+BU
DRA 12-30-DB12.5+BU
DRA 16-30-D16+BU
44
45
46
47
1
1
1
1
2.760
2.760
2.760
2.760
DRA 26-30-DB20+BU
DRA 26-30-DB25+BU
48
49
1
1
3.020
3.020
Emb.
Peso
en
uds.
kg
(V) 60 Hz
Cdigo
Circuito mando
SB7470C2
HK-20
ABB
Baja Tensin
Descripcin
Contactos
Tipo
Simutneos
HK-20
Cdigo de pedido
uds.
kg
10
0.031
Emb.
Tipo
uds.
Peso
en
kg
Prensaestopas Pg 16 / CM14P
FPCM 14P
0.013
Prensaestopas Pg 21 / CM18P
FPCM 18P
0.015
Cdigo de pedido
2/11
1TXA0CC001D0703
YRA ...
Arrancadores estrella-tringulo en caja
Proteccin mediante rel trmico de sobrecarga
Detalles para pedido
SB8002C3
Indicar tensin
aM
A
gG
A
mando
de mando
15.5
22
30
16
25
32
25
35
50
YRA 9-30
YRA 12-30
YRA 16-30
7.5
11
15
5.5
7.5
11
Proteccin
contra cortocircuitos *
Coordinacin tipo 1 segn
EN 60947-4-1 / IEC 947-4-1
380-400 V
Tipo
Emb.
Cdigo de pedido
00
00
00
uds.
1
1
1
Peso
kg
3.020
3.020
3.020
* Para otros dispositivos de proteccin contra cortocircuitos, consultar nuestras tablas de coordinacin.
YRA 9-30
(V) 60 Hz
Cdigo
Circuito mando
debe conectarse
a una alimentacin independiente
o entre fase y fase
o entre fase y neutro
E1376D
Caja de plstico - UL 94 V2
Doble aislamiento - Proteccin IP 64
2/12
1TXA0CC001D0703
ABB
Baja Tensin
YRA ... D
Arrancadores estrella-tringulo en caja
Proteccin mediante guardamotor
Detalles para pedido
Coordinacin Iq = 50 kA y tensin de empleo < 415 V
Potencias
motor 4 polos
50/60 Hz
Coordina- Regulacin
cin
Iq = 50 kA
SB8005C3
380-400-415 V
kW ... kW
YRA 9-30 DB + BU
Tipo
Peso
en
kg
Embal.
1 ud.
Cdigo de pedido
Indicar tensin
de mando
Aadir cdigo
tensin mando
YRA 9-30-D9.0
YRA 9-30-D12.5
YRA 9-30-D16
YRA 12-30-D25
45
46
47
49
3.450
3.450
3.450
3.450
YRA ... DB - Con bobina de mnima tensin (circuito de potencia 380 ... 415 V - 50 Hz)
3.0 ... 4.0
1
6.3 ... 9.0
YRA 9-30-DB9.0
1SBK 142 922 R8
1SBK 142 922 R8
5.0 ... 5.5
1
9.0 ... 12.5 YRA 9-30-DB12.5
6.5 ... 7.5
1
12.5 ... 16
YRA 9-30-DB16
1SBK 142 922 R8
... 11.0
1
20.0 ... 25.0 YRA 12-30-DB25
1SBK 162 922 R8
45
46
47
49
3.450
3.450
3.450
3.450
YRA ... D
3.0 ... 4.0
5.0 ... 5.5
6.5 ... 7.5
... 11.0
1
1
1
1
... A
6.3 ...
9.0 ...
12.5 ...
20.0 ...
9.0
12.5
16
25.0
YRA ... DB+BU - Con bobina de mnima tensin (circuito de potencia 380 ... 415 V - 50H) y pulsador seta parada emergencia
3.0 ... 4.0
1
6.3 ... 9.0
YRA 9-30-DB9.0+BU
1SBK 142 924 R8 45
3.580
1SBK 142 924 R8 46
3.580
5.0 ... 5.5
1
9.0 ... 12.5 YRA 9-30-DB12.5+BU
6.5 ... 7.5
1
12.5 ... 16
YRA 9-30-DB16+BU
1SBK 142 924 R8 47
3.580
... 11.0
1
20.0 ... 25.0 YRA 12-30-DB25+BU
1SBK 162 924 R8 49
3.580
Cdigo tensin mando Tensin (V) 50 Hz
(V) 60 Hz
Cdigo
0
5
E1378D
ABB
Baja Tensin
2/13
1TXA0CC001D0703
WRA ...
Arrancadores inversores en caja
Proteccin mediante rel trmico de sobrecarga
SB8004C3
WRA 9-30
Corriente Potencia
asig.
AC-3
empleo motor 4polos
AC-3
50/60 Hz
380 V
400 V
400 V 690 V
A
kW
kW
aM
A
gG
A
9
12
17
26
32
37
10
16
20
25
32
40
25
32
32
50
63
80
4
5.5
7.5
11
15
18.5
5.5
7.5
9
15
18,5
22
Fusibles
Tipo
Emb.
Cdigo de pedido
Indicar tensin
de mando
Aadir cdigo
tensin mando
WRA 9-30
WRA 12-30
WRA 16-30
WRA 26-30
WRA 30-30
WRA 40-30
00
00
00
00
00
00
Peso
en
uds.
kg
1
1
1
1
1
1
2.620
2.620
2.620
3.170
3.520
3.520
* Para otros dispositivos de proteccin contra cortocircuitos, consultar nuestras tablas de coordinacin.
(V) 60 Hz
Cdigo
Circuito mando
E1371D
Caja de plstico - UL 94 V2
Doble aislamiento - Proteccin IP 64
2/14
1TXA0CC001D0703
ABB
Baja Tensin
WRA ...
Arrancadores inversores en caja
Proteccin mediante rel trmico de sobrecarga
Rel trmico de sobrecarga
Tipo
arrancador
Regulacin
WRA 9-30
hasta
WRA 30-30
TA 25 DU 0.16
TA 25 DU 0.25
TA 25 DU 0.4
1
1
1
0.150
0.150
0.150
TA 25 DU 0.63
TA 25 DU 1.0
TA 25 DU 1.4
1
1
1
0.150
0.150
0.150
1.3
1.7
2.2
... 1.8
... 2.4
... 3.1
TA 25 DU 1.8
TA 25 DU 2.4
TA 25 DU 3.1
1
1
1
0.150
0.150
0.150
2.8
3.5
4.5
... 4.0
... 5.0
... 6.5
TA 25 DU 4.0
TA 25 DU 5.0
TA 25 DU 6.5
1
1
1
0.150
0.150
0.150
6.0
7.5
10
... 8.5
... 11
... 14
TA 25 DU 8.5
TA 25 DU 11
TA 25 DU 14
1
1
1
0.150
0.150
0.150
13
18
24
... 19
... 25
... 32
TA 25 DU 19
TA 25 DU 25
TA 25 DU 32
1
1
1
0.150
0.150
0.170
18
22
29
... 25
... 32
... 42
TA 42 DU 25
TA 42 DU 32
TA 42 DU 42
1
1
1
0.330
0.330
0.330
SB7386C2
SB7361S3
TA 25 DU
TA 42 DU
SB7587C4
WRA 40-30
BA5-50
Tipo
Cdigo de pedido
... A
Emb.
Peso
en
uds.
kg
SB7603C2
SB7375C4
CAL 5-11
CB5-10
SB7585C2
SB7571C3
CA5-10
LP25
Cdigo de pedido
Emb.
BA5-50
caja
0.017
CA5-10
10
0.014
CA5-01
10
0.014
0.050
CB5-10
0.012
CB5-01
0.012
LP 16
10
0.002
LP 25
10
0.004
Descripcin
Tipo
Cdigo de pedido
Emb. Peso
en
uds. kg
FPCM 14P
0.013
Prensaestopas Pg 21 / CM18P
FPCM 18P
0.015
Baja Tensin
Tipo
Prensaestopas Pg 16 / CM14P
ABB
Peso
en
kg
2/15
1TXA0CC001D0703
Coordina- Regulacin
cin
Iq = 50 kA
SB8000C3
380-400-415 V
kW ... kW
2.2
3.0
5.0
6.5
...
...
...
...
Tipo
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
11.0
2
2
Emb.
Cdigo de pedido
Peso
en
Indicar tensin
de mando
Aadir cdigo
tensin
mando
uds.
kg
WRA 9-30-D6.3
WRA 9-30-D9.0
WRA 12-30-D12.5
WRA 16-30-D16
44
45
46
47
1
1
1
1
3.060
3.060
3.060
3.060
WRA 26-30-D20
WRA 26-30-D25
48
49
1
1
3.600
3.600
WRA 9-30 D
(V) 60 Hz
Cdigo
Circuito mando
debe conectarse al circuito
de potencia bien entre fase y fase
o entre fase y neutro (1).
(1) Proporcionar un bloque de contacto auxiliar HK20 para interrupcin del neutro (vase pgina 2/17)
E1374D
2/16
1TXA0CC001D0703
ABB
Baja Tensin
Coordina- Regulacin
cin
Iq=50kA
SB8000C3
380-400-415 V
kW ... kW
WRA 16-30 DB
2.2
3.0
5.0
6.5
...
...
...
...
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
11.0
2
2
Tipo
Cdigo de pedido
Emb. Peso
en
Indicar tensin
de mando
Aadir cdigo
tensin
mando
WRA 9-30-DB6.3
WRA 9-30-DB9.0
WRA 12-30-DB12.5
WRA 16-30-DB16
44
45
46
47
WRA 26-30-DB20
WRA 26-30-DB25
uds.
kg
1
1
1
1
3.060
3.060
3.060
3.060
48 1
49 1
3.600
3.600
(V) 60 Hz
Cdigo
Circuito mando
Coordina- Regulacin
cin
Iq=50kA
SB8003C3
380-400-415 V
kW ... kW
WRA 26-30 DB + BU
2.2
3.0
5.0
6.5
...
...
...
...
8.0 ...
... A
2.5
4.0
5.5
7.5
1
1
1
1
4.0 ...
6.3 ...
9.0 ...
12.5 ...
6.3
9.0
12
16
9.0
11.0
2
2
Peso
en
kg
Embal.
1 ud.
Tipo
Cdigo de pedido
Indicar tensin
de mando
Aadir cdigo
tensin
mando
WRA 9-30-DB6.3+BU
WRA 9-30-DB9.0+BU
WRA 12-30-DB12.5+BU
WRA 16-30-D16+BU
44
45
46
47
3.200
3.200
3.200
3.200
WRA 26-30-DB20+BU
WRA 26-30-DB25+BU
48
49
3.740
3.740
(V) 60 Hz
Cdigo
Circuito mando
SB7470C2
HK-20
ABB
Baja Tensin
Descripcin
Contactos
Tipo
Simultneos
HK-20
Cdigo de pedido
Emb. Peso
en
uds. kg
10
0.031
Emb. Peso
en
uds. kg
Descripcin
Tipo
Prensaestopas Pg 16 / CM14P
FPCM 14P
0.013
Prensaestopas Pg 21 / CM18P
FPCM 18P
0.015
2/17
1TXA0CC001D0703
135
Entradas cables
Arriba
Salidas cables
Abajo
2 x 23/28.5
2 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
E 0459D1
128
E 0458D1
100
E 0457D1
180
198
2x
5,5
407769X3
407769X2
407769X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
407771X3
407771X2
407771X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
407773X3
407773X2
407773X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
DRA ... DB + BU
2/18
1TXA0CC001D0703
ABB
Baja Tensin
407769X3
407769X2
407769X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
YRA ...
407771X3
407771X2
407771X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
407773X3
407773X2
407773X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
YRA ... DB + BU
ABB
Baja Tensin
2/19
1TXA0CC001D0703
407770X3
407770X2
407770X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
407772X3
407772X2
407772X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
407774X3
407774X2
407774X1
Entradas cables
Arriba
Salidas cables
Abajo
3 x 23/28.5
3 x 23/28.5
23 para Pg 16 / CM 14P
28.5 para Pg 21 / CM 18P
WRA ... DB + BU
2/20
1TXA0CC001D0703
ABB
Baja Tensin
Notas
ABB
Baja Tensin
2/21