Employers Requirements

Part5-1

SECTION VI
PART 5
TECHNICAL SCHEDULES

Section VI. Employers Requirements

Part5-2

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(A) 33 KV OUTDOOR CIRCUIT BREAKER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
The VCB and CT shall be on one structure
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl
No
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

23
24
25

Bidders
Deviation
Description
Unit
Guaranteed
(Yes/No)
Values
33 KV CIRCUIT BREAKER (INCOMING/ TRANSFORMER) FEEDER
The VCB and CT shall be on one structure
Manufacturers Name & Country
Required
Manufacturers Address
Required
Type Number
Required
-------------------Maximum Rated voltage
kv
36
Frequency
Hz
50
Rated Normal Current
A
630
No of Phases
3
No. of breaks per phase
Required
Interrupting medium
Vacuum
Impulse Withstand,
kV
90
Short time withstand, 3 sec rms
kA
25
Breaking Capacity :
Symmetrical, RMS
kA
31.5
Asymmetrical, RMS
kA
Short circuit. Making Current, Peak
kA
62.5
First phase to clear factor
1.5
Rated transient recovery voltage at
kVP
Required
100% rated short cct breaking current
Line charging breaking currents
A
Required
Cable charging breaking current
A
Required
Is circuit breaking re-strike free?
Y/N
Yes
Trip coil current
A
Trip coil Voltage
V
DC 110
Is the circuit breaker trip free?
Y/N
Yes
Type of Main Contact
Required
--------------------Materials of Contact surfaces
Contact Resistance
Required
Weight of circuit Breaker unit
Kg.
Required
complete, without operating
mechanism and structure
Wt. of circuit Breaker complete with
Kg.
Required
all fittings as in service.
Maximum shock load imposed on
N
Required
floor or foundation when
opening under fault conditions
(State compression or tension)
REB
Requirement

Section VI. Employers Requirements

26

27
28

Part5-3

Operating Particulars :
Rated Breaking Time
ms
Required
Cycle
ms
--------------------Rated Closing time
mS
--------------------Maximum Arc duration of any duty
ms
Required
cycle of IEC 56-2
0Rated Operating Sequence
Required
0.3secCO3minCO

29

38
39

Rated voltage of spring winding motor


for closing.
Spring winding motor current
Closing release coil current
Closing release coil voltage
Minimum clearance in air :
Between phases
Phases to earth
Across circuit breaker poles
Live conductor to ground level
Live insulator to ground level
Material of Tank or Chamber
Material of Moving Contact tension
rod.
Period of time, equipment has been in
service
Period of time, equipment has been
under manufacture
No. of tripping coil
Creepage distance (minimum)

40

Life of Interrupter

41

Pressure in vacuum tube for VCB,


Guaranteed Number of Operation
For CB without maintenance:
At rated current switching
At short circuit current switching
All current carrying parts of CB shall
be made of
Number of spare auxiliary contacts
( NO + NC)

30
31
32
33

34
35
36
37

42
43

240 AC

A
A
V

Required
Required
110 DC

mm
mm
mm
mm
mm

370
325

Required
Required
Year
s
Year
s
Nos.
kv/
mm
Year
s
Bar
Nos.
Nos.
Nos.

2
5
2
25
Required

100
Copper
4+4

Section VI. Employers Requirements

Part5-4

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(B) 11 KV AIR INSULATED FEEDER AND ACR
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
The VCB and CT shall be on one structure
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl
No

Description

Unit

REB
Requirement

INCOMING FEEDER EQUIPMENT UNITS


1
2
3
4
5
6
7
8

9
10
11

12

Bus bar :
Material
Copper
Cross Section
mm2
Required
Applied standard
Required
Rated nominal voltage
kV
11
Rated maximum voltage
kV
12
Rated current for main bus
A
1250
Rated short time current
kA
25
Short time current rated duration
Sec.
3
LINE FEEDER EQUIPMENT UNITS
Automatic Circuit Recloser (ACR)
Applied Standerd
Required
Rated voltage(max)
kV
15
Rated current
A
630
Rated short circuit breaking current
kA/sec
16/3
Rated short circuit making current
kA
31
Number of phases
3
Rated breaking time
cycle
5
Opening time
msec.
Required
Closing time
msec.
Required
Operating curves
Required
Control voltage
V
240 V AC
Interrupting chamber
Vacuum
Rated frequency Hz
50
Withstand Voltage
AC withstand voltage 1 min. dry
kV
28
Basic Impulse level
kV
110
ACR disconnect Switch
Standard :
Required
Type
Required
15
Rated Voltage(max)
kV
630
Rated current
A
Number of Pole
1
ACR bypass Switch :
Standard :
Required
Type
Required
Rated Voltage(max)
15

Bidders
Guaranteed
Values

Deviation
(Yes/No)

Section VI. Employers Requirements

Part5-5

kV
630

Rated current

13

14

15

16

17

18
19

20
21

A
Number of Pole
1
Dimension and weight(ACR) :
Height
mm
Required
Width
mm
Required
Depth
mm
Required
Weight including circuit breaker
Kg.
Required
11 k VOLTAGE TRANSFORMER UNITS
Voltage Transformer :
Number of phase
1
Rated primary voltage
Rated secondary voltage
Rated burden, Secondary
Accuracy class
Power Fuse :
Rated voltage
Rated current
Rated short Ckt. breaking current
Dimension and Weight :
Height
Width
Depth
Wt. including voltage transformer
Degree of Protection
Enclosure
HV Compartment
LV Compartment

kV
V
VA

11/3
110/3
50
0.2

kV
A
kA

12
100
25

mm
mm
mm
Kg.

Required
Required
Required
Required
IP3X
IP65
IP40
Required
Required

Insulation Level
a. Multifunction Meter
Manufacturer
b. Current Transformer
Ratio

kV

Period of time, equipment has been in


service
Period of time, equipment has been
under manufacture

Years

Years

Required

Section VI. Employers Requirements

Part5-6

TECHNICAL EQUIREMENT AND GUARANTEE SCHEDULE


(C) 11 kV SWITCHGEAR PANELS AND CONTROL EQUIPMENT
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl
No

Description

Unit

REB
Requirement

Line Feeder Switchgear unit


1. Metalclad Switchgear
Required
2. Arc fault Containment
Required
3. Manufacturers Name & Address
Required
4. Applied standard
Required
Type of insulation
Air
5. Rated nominal voltage
kV
11
6. Rated Voltage
kV
12
7. Rated current for main bus
A
630
8. Rated short time current
kA
25
9. Short time current rated duration
sec
3
10. Circuit Breaker :
Type
Vacuum CB
Rated Voltage
kV
12
Rated Current
A
630
Rated short Ckt. breaking current
kA
25
Rated short Ckt. making current
kA
62.5
Rated breaking time
Cycle
5
Opening time
Sec
Required
Closing time
Sec.
Required
0-0.3sec-CORequired
Rated operating sequence
3min-CO
Minimum number of operations at
rated short circuit current without
maintenance
Arc fault withstand capabilty

No.

100
IAC(IEC
62271-200)
Yes

Motor Spring charged operating


Mechanism:
Manufacturer type designation
Required
Rated voltage closing coil/tripping
V
DC 110
coils
Rated voltage of motor
V
DC 110
Number of tripping coils/power
No./W
1/W
consumptiuon
Number of closing coils/power
No./W
1/W
consumptiuon
Number of spare auxiliary contacts
No.
4+4
NO+NC)
11.
Current Transformer :
Rated Voltage
kV
12
Accuracy class, Metering
0.2

Bidders
Guaranteed
Values

Deviation
(Yes/No)

Section VI. Employers Requirements

Accuracy class, Protection


Rated current ratio
Burden
12.
Hz
13.
14.

15.
16.
17.

18.
19.
20.
21.
22.
23.
24.
25.

26.

27.
28.

29.

Part5-7

A
VA
Rated frequency

5P10
200-100/5,5
30
50

Insulation level
AC withstand voltage 1 min. dry
kV
28
Impulse withstand, full wave
kV
75
Degree of Protection
Enclosure
IP4X
Required
HV Compartment
IP65
Required
LV Compartment
IP40
Required
Earthing Switch :
Type
Short Time Current, 3 Secs.
kA
25
Bus bar :
Material
Copper
Required
2
Cross Section
mm
Required
Dimension and Weight
Height
mm
Required
Width
mm
Required
Depth
mm
Required
Weight including Circuit Breaker
Kg.
Required
Voltage Transformer Switchgear units
Manufacturers Name & Address
Required
Busbar:
Material
Copper
Cross Section
mm2
Required
Rated nominal voltage
kV
11
Rated voltage
kV
12
Rated current for main bus
A
1250
Rated short time current
kA
25
Short time current rated duration
sec
3
Voltage Transformer:
V
Rated primary voltage
11/3
V
Rated secondary voltage
110/3
Rated burden, Secondary
VA
50
Accuracy class
0.2
Power Fuse:
Rated voltage
kV
12
Rated current
A
10
Rated short circuit breaking current
kA
25
Insulation level
AC withstand voltage 1 min. dry
kV
28
Impulse withstand, full wave
kV
75
Degree of Protection
Enclosure
IP4X
Required
HV Compartment
IP65
Required
LV Compartment
IP40
Required
Dimension and Weight
Height
mm
Required

Section VI. Employers Requirements

30

30
31

Width
Depth
Weight including Circuit Breaker
11kV Isolator
Rated Voltage & Frequency
Maximum Contineous voltage
Rated Current
Rated Short time current (1 sec)
Impulse withstand voltage
Power Frequency withstand
voltage(1 min)
Period of time, equipment has been
in service
Period of time, equipment has been
under manufacture

Part5-8

mm
mm
Kg.

Required
Required
Required

kV/Hz
kV
A
kA
kV
kV

11, 50
12
1250
25
75
28

Years

Years

Section VI. Employers Requirements

Part5-9

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(D) 33 kV POTENTIAL TRANSFORMER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
SI
No
1
2
3
4

Description

Unit

Name of the Manufacturer


Type & Model No
Nominal System Voltage
Heights System Voltage

kV
kV

REB
Requirement
Required
Required
33
36

5
6

Rated Primary Voltage


Rated secondary Voltage
and Tertiary voltage

kV
V

33/3
110/3

Impulse withstand voltage


(1.2/50 micro sec.)
Power frequency
withstand voltage
Period of time, equipment
has been in service
Period of time, equipment
has been under
manufacture
Burden/Class

kV

110/3
170

kV

70

Years

Years

VA

50VA /Class
0.2

8
9
10
11

a) Metering winding

Bidders
Guaranteed Values

Deviation
(Yes/No)

Section VI. Employers Requirements

Part5-10

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(E) 33 kV CURRENT TRANSFORMERS
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
SI
No

Description

1
2
3

Name of the Manufacturer


Type & Model No
Voltage-Maximum (Cont.)

4
5
6
7

Continuous
Frequency
Impulse withstand voltage
Power frequency
withstand voltage (1 min.)
C.T. Ratio

Unit

kV/Hz

Required
Required
36

kV
Hz
kV
kV

33
50
170
70

a) Incoming
8
9

Number of core
Rated output & accuracy

300/150/5-5A
--

Incoming
a) core-1 (meas)

14
15
16

Width
Length
Total creep age distance
Short Circuit Current
rating (3 sec)
Total weight of one single
phase unit.
Period of time, equipment
has been in service
Period of time, equipment
has been under
manufacture

30VA, 0.2
FS5
30VA, class,
5P10

b) core-2 (prot)
10
11
12
13

REB
Requirement

mm
mm
mm
kA

Required
Required
Required
25

Kg
Years

Years

Bidders
Guaranteed Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-11

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(F) 33 kV SURGE ARRESTER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl
No

Description

Unit

REB
Requirement

2.

33 KV SURGE ARRESTER
Manufacturers Name &
Address
Class of diverter to IEC 99-4

3.

Rated voltage (RMS)

kV

4.
5.

Rated current
Neutral connection

kA

10
Effectively
earthed

6.

Power frequency withstand


voltage of housing:
Dry :
Impulse:
Lighting impulse residual
voltage
Steep current impulse
residual voltage at 10 kA or 1
S front time
Pressure relief device
fitted?
Leakage current at rated
voltage
Minimum reset voltage
Total creepage distance
Surge monitor
Period of time, equipment
has been in service
Period of time, equipment
has been under manufacture
Connecting Lead from LA
terminal to surge monitor:

kV
kV
kV

70 (RMS)
170
100 peak

kV

110

Y/N

Required

Required

V
mm

Required
Required
Required
2

1.

7.
8.
9.
10.
11.
12.
13.
14
15
16

17

Overall dimension and


Weight :
Height
Diameter
Total weight of arrester
Height

Bidders
Guaranteed Values

Required

Year
s
Year
s

Heavy duty,
ZnO
30

5
Shall be
Insulated 16
mm2 copper
cable

mm
mm
Kg.
mm

Required
Required
Required
Required

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE

Deviation
Yes/No

Section VI. Employers Requirements

Part5-12

(G) 11 kV SURGE ARRESTER


( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
SI
No
1.
2.
3.
4.
5.
6.

7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.

Description

Unit

11 KV SURGE ARRESTER
Manufacturers Name &
Address
Class of diverter to IEC 994
Rated voltage (RMS)
kV
Rated current
Neutral connection
Power frequency withstand
voltage of housing:
Dry :
Impulse:
Lighting impulse residual
voltage
Steep current impulse
residual voltage at 10 kA or
1 S front time
Pressure relief
device fitted?
Leakage current at rated
voltage
Minimum reset voltage
Total creepage distance
Surge monitor
Connecting Lead from LA
terminal to surge monitor:
Period of time, equipment
has been in service
Period of time, equipment
has been under manufacture
Overall dimension and
Weight :
Height
Diameter
Total weight of arrester
Height

kA

REB
Requirement
Required
Heavy duty, ZnO
10
10
Effectively earthed
Required

kV
kV
kV

28(RMS)
70
Required

kV

Required

Y/N

Required

Required

V
mm

Years

Required
Required
To be provided
Shall be Insulated 16
mm2 copper cable
2

Years

mm
mm
Kg.
mm

Required
Required
Required
Required

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-13

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(H) 11kV CABLES AND CABLE ACCESSORIES
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
SI
No
1.
2.
3.
4.
5.

Description
11 KV Cables
Manufacturers name &
address
Type
Applied Standard

7.

Rated frequency
Rated voltage
System voltage
Maximum system voltage
Number of cores x Core
area
Type of phase conductor

8.
9.

Material of phase conductor


Conductor screen material

10.
11.
12.

Screen nominal thickness


Type of curing
Rated current (As per IEC
Std.)
Ambient temperature (30oC)
Max. conductor
temperature (90oC)
Insulation resistance, +25oC
Capacitance
Type of insulating material
Dimensions:
Diameter of each strand
Diameter of conductor
Thickness of insulation
Thickness of inner sheath
Thickness of outer sheath
Overall diameter
Approximate weight

6.

13.
14.
15.
16.

17.
18.

Unit

Max. conductor resistance,


+25oC

REB
Requirement
Required
XLPE
Required

Hz
kV
kV
kV

mm

50
10
11
12
1C, 185 mm2
Compact,
Round
Copper
Semi conducting
PE
0.6
Dry Curing
Required

A
A

Required
Required

/Km
F/Km

Required
Required
XLPE

mm
mm
mm
mm
mm
mm
Kg./K
m
/Km

Required
Required
Required
Required
Required
Required
Required

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

19.
20.
21
22
23.

24.

25.

Power frequency withstand


voltage
Impulse withstand voltage
Period of time, equipment
has been in service
Period of time, equipment
has been under manufacture
Drum:
Type
Diameter
Cable length/Drum
KIT CONTENT (OUT
DOOR)
Termination jointing kit for
11kV XLPE cables 1C, 185
mm2
Copper conductor (Outdoor)
Heat shrinkable high
voltage insulation and nontracking tubing.
Heat shrinkable stress
control tubing.
Stress relieving mastic strip.
Track resistant sealant tape.
Heat shrinkable track
resistant rain skirt
Support Insulator.
Cable preparation Kit.
Solderless earth connection
Kit
Compression lugs
Support Insulators Tee
brackets
Installation Instructions.
KIT CONTENT
(INDOOR):
Termination jointing kit for
11kV XLPE cables 1C, 185
mm2
Copper conductor (Indoor)
Totally Insulated panel
termination type, complete
in all respect as suitable for
switchgear, plug-in Type.

Part5-14

kV

15

kV
Years

75
2

Years

mm
M

Steel
Required
Required
Required

Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required
Required

Required
Required
Required

Section VI. Employers Requirements

Part5-15

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(I) 33 kV ISOLATOR /EARTH SWITCH
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description
1. Name of the manufacturer
2. Switch Type & Model
3. Rated Voltage & Frequency
4. Maximum Continuous voltage
5. Rated Current
6. Rated Short time current (1 sec)
7. Impulse withstand voltage
8. Power Frequency withstand
voltage(1 min)
9.Creepage Distance
10. Dimension of the supporting
steel
structure
Height
Width
Length
11. Weight of the phase units
12. Phase center distance
13. Period of time, equipment has
been in service
14. Period of time, equipment has
been under manufacture
15. Earth Switch
Manufacturer
Country of Manufacture
Manufacturer type designation
Reference Standard
Number of years disconnector
type in service
Nominal system Voltage
Highest system voltage
Frequency
Rated current
Type of operating mechanism

Unit

kV/Hz
kV
A
kA
kV
kV

REB
Requirement
Required
Required
33, 50
36
630
25
170
70

mm

Required
Required

mm
mm
mm
kg
mm
Years

Required
Required
Required
Required
Required
2

Years

5
Required
Required
Required
Required
Required
Required

kV
kV
Hz
A

33
36
50
1250
Hand

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-16

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(J) 11 kV ISOLATOR
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description

Unit

1. Name of the manufacturer


2. Switch Type & Model
3. Rated Voltage & Frequency
kV/Hzs
4. Maximum Continuous voltage
kV
5. Rated Current
A
6. Rated Short time current (1
kA
sec)
7. Impulse withstand voltage
kV
8. Power Frequency withstand
kV
voltage(1 min)
9.Creepage Distance
mm
10. Dimension of the supporting
steel
structure
Height
mm
Width
mm
Length
mm
11. Weight of the phase units
kg
12. Phase center distance
mm
13.Period of time, equipment has Years
been in service
14.Period of time, equipment has Years
been under manufacture

REB
Requirement
Required
Required
11, 50
12
1250
25
75
28
Required
Required
Required
Required
Required
Required
Required
2
5

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-17

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(K) 33 kV, DOUBLE BREAK SWITCHED FUSE
(If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description
1. Name of the manufacturer
2. Switch Type & Model
3. Rated Voltage & Frequency
4. Maximum Continuous voltage
5. Rated Current
6. Rated Short time current (1 sec)
7. Impulse withstand voltage
8. Power Frequency withstand
voltage(1 min)
9. Fuse Type
10. Fuse Rating
11.Creepage Distance
12. Dimension of the supporting
steel structure
Height
Width
Length
13. Weight of the phase units
14. Phase center distance
15.Period of time, equipment has
been in service
16.Period of time, equipment has
been under manufacture

Unit
Dual
Break
kV/Hzs
kV
A
kA
kV
kV

REB
Requirement
Required
Required
33, 50
36
630
25
170
70

A
mm

Required
630
Required
Required

mm
mm
mm
kg
mm
Years

Required
Required
Required
Required
Required
2

Years

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-18

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(L) 33/11.55 kV 5/6.25MVA POWER TRANSFORMERS
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description
1.
2.
3.
4.

Manufacturers Name
Manufacturers Address
Applied Standard
Type

5.

(a)Rated Power

Unit

MVA

(b) Overload Capability


Number of Phase
Rated Voltage, Phase to
Phase
High Voltage winding
Low Voltage winding
8.Rated frequency
Hz
50
--------------------

In accordance
with IEC
603564
Three

6.
7.

9. Rated insulation level


a) Impulse withstand, full wave
High voltage winding
Low voltage winding
Neutral side
(b) AC withstand voltage
High voltage winding
Low voltage winding
10. Vector Diagram (IEC 76-4)
11. Type of Cooling, 10/12.5
MVA
12. On load Tap changer (MR
Germany or ABB ) with Vacuum
Switches
Type
Rated tap
Tap range
Numbers of tap
Tap step
Location of tap
Rated short time current
Oil volume

REB
Requirement
Required
Required
Required
Outdoor
Oil immersed
ONAN/ONAF
5/6.25 MVA

kV
kV
Hz

33
11.55
50

kV
kV

170
75
Full insulation

kV
kV
Dyn11

70
28
Required

ONAN
/ONAF

Required
Required

kV
%
Taps
%
kA
Litre

Required
33
- 6 to +15
15
1.5
Primary side
Required
Required

Bidders
Guaranteed Values

Deviation
Yes/No

Section VI. Employers Requirements

Duration of one step change


Motor rating
13. Impedance voltage at 75o C
and at nominal ratio and 100%
rated power at principal tap
14.Temperature rise at rated
power (Max. ambient
temperature: 40o C)
Oil by thermometer
Winding by resistance
measurement.
16.Transformer core: Type of
core, Max. flux density At
nominal voltage
-------------------17. Transformer bushings
(a) H.V. Bushing
Voltage class
Cantilever strength
Transformer bushing HV CT
- Currrent Ratio
- Rated burden
- Accuracy
18. Conservator
19. Auxiliary circuit voltage for
fan, etc, 3phase 4wire
20. Control Voltage
21. Sound level (IEC 60551)
ONAN(0.3m)
ONAF (2m)
22. Transformer Bushing LV CT
On phase a (OLTC)
- Current Ratio
- Rated burden
- Accuracy
- Short time current
On phase b (WTI)
- Current Ratio
- Rated burden
- Accuracy
- Short time current
Neutral Bushing CT for REF :
- Current Ratio
- Rated burden
- Accuracy
Neutral Bushing CT for stand by
earth fault
- Current Ratio
- Rated burden
- Accuracy

Part5-19

sec
kW
7%

Required
Required
Required

deg.
C.
deg.
C.

60

Tesla

1.9

65

Required
Required
Required
100/5
30
Class 5P10
Required
415/240 AC

110 DC

dB
dB

Required
<80

A
VA

300/5
30
Class 5P10

A
VA

kA
A
VA

300/5
30
Class 5P10

kA
A
VA

300/5
30
Class 5P10

A
VA

300/5
30
Class 5P10

Section VI. Employers Requirements

- Short time current


23. Number of Cooling fan
24. Rating of Fan motors
25. Cooling fan losses at full
ONAF capacity operation
26. Core Loss at rated frequency
and rated voltage at nominal tap.
27. Copper Loss at full load, at
rated
frequency and at 75 oC
(a) At Maximum Tap
(b) At Nominal Tap
(c) At Minimum Tap
28. Exciting Current at nominal
tap and rated voltage.
29. Dimensions and Weight
Maximum size for transport L x
WxH
Heaviest weight for transport
Overall height
Oil volume
Weight of oil
Weight of core
Total weight
Dimensions and Weight
30.Period of time, equipment has
been in service
31.Period of time, equipment has
been under manufacture

Part5-20

kA
Nos.
kW.
kW

25
Required
Required

kW

Required
Required

kW
kW
kW
A

Required
Required
Required
Required
Required

mm

Required
Required

Kg
mm
Litre
Kg
Kg
Kg

Required
Required
Required
Required
Required
Required

Years

Years

Section VI. Employers Requirements

Part5-21

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(M) 33/11.55 kV 10/12.5MVA POWER TRANSFORMERS
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description

Unit

1. Manufacturers Name
2. Manufacturers Address
3 Applied Standard
4 Type
5 (a)Rated Power

MVA

(b) Overload Capability


6 Number of Phase
7 Rated Voltage, Phase to
Phase
High Voltage winding
Low Voltage winding
8.Rated frequency
Hz
50
-------------------9. Rated insulation level
a) Impulse withstand, full wave
High voltage winding
Low voltage winding
Neutral side
(b) AC withstand voltage
High voltage winding
Low voltage winding
10. Vector Diagram (IEC 76-4)
11. Type of Cooling, 10/12.5 MVA

12. On load Tap changer (MR


Germany or ABB ) with Vacuum
Switches
Type

kV
kV
Hz

REB
Requirement
Required
Required
Required
Outdoor
Oil immersed
ONAN/ONAF
10/12.5 MVA
Three Phase
In accordance
with IEC
603564
Three
Required
33
11.55
50

Required
kV
kV
kV
kV
Dyn11
ONA
N /
ONA
F

170
75
Full insulation
70
28
Required
Required

Required
Required

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Rated tap
Tap range
Numbers of tap
Tap step
Location of tap
Rated short time current
Oil volume
Duration of one step change
Motor rating
13. Impedance voltage at 75o C
and at nominal ratio and 100%
rated powerat principal tap
14.Temperature rise at rated power
(Max. ambient temperature: 40o C)
Oil by thermometer
Winding by resistance
measurement.
16.Transformer core: Type of core,
max. flux density At nominal
voltage
-------------------17. Transformer bushings
(a) H.V. Bushing
Voltage class
Cantilever strength
Transformer bushing HV CT
- Currrent Ratio
- Rated burden
- Accuracy
18. Conservator
19. Auxiliary circuit voltage for
fan, etc, 3phase 4 wire
20. Control Voltage
21. Sound level (IEC 60551)
ONAN (0.3m)
ONAF (2 m)
22. Transformer Bushing LV CT
On phase a (OLTC)
- Current Ratio
- Rated burden
- Accuracy
- Short time current
On phase b (WTI)
- Current Ratio
- Rated burden
- Accuracy
- Short time current
Neutral Bushing CT for REF :
- Current Ratio
- Rated burden

Part5-22

kV
%
Taps
%
kA
Litre
sec
kW
8%

33
- 6 to +15
15
1.5
Primary side
Required
Required
Required
Required
Required
Required

deg.
C.
deg.
C.

60

Tesla

1.9

65

Required
Required
Required
200/5
30
Class 5P10
Required
415/240 AC

110 DC

dB
dB

Required
<80

A
VA

600/5
30
Class 5P10

A
VA

kA
A
VA

600/5
30
Class 5P10

kA
A
VA

600/5
30

Section VI. Employers Requirements

- Accuracy
Neutral Bushing CT for stand by
earth fault
- Current Ratio
- Rated burden
- Accuracy
- Short time current
23. Number of Cooling fan
24. Rating of Fan motors
25. Cooling fan losses at full
ONAF capacity operation
26. Core Loss at rated frequency
and rated voltage at nominal tap.
27. Copper Loss at full load, at
rated
frequency and at 75 oC
(a) At Maximum Tap
(b) At Nominal Tap
(c) At Minimum Tap
28. Exciting Current at nominal tap
and rated voltage.
29. Dimensions and Weight
Maximum size for transport L x
WxH
Heaviest weight for transport
Overall height
Oil volume
Weight of oil
Weight of core
Total weight
Dimensions and Weight
30.Period of time, equipment has
been in service
31.Period of time, equipment has
been under manufacture

Part5-23

Class 5P10
A
VA
kA
Nos.
kW.
kW
kW

600/5
30
Class 5P10
25
Required
Required
Required
Required

kW
kW
kW
A

Required
Required
Required
Required
Required

mm

Required
Required

Kg
mm
Litre
Kg
Kg
Kg
Years

Required
Required
Required
Required
Required
Required
Required
2

Years

Section VI. Employers Requirements

Part5-24

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(N) 33/0.433 kV STATION TRANSFORMER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Description

Unit

REB
Requirement

STATION SERVICE TRANSFORMERS


1. Manufacturers Name
Required
2. Manufacturers Address
Required
3. Type
Required
4. Applied Standard
5. Rated power
kVA
100
6. Rated voltage :
High voltage winding
kV
33
Low voltage winding
V
433 / 250
7. Vector diagram
Dyn 11
8. Rated Frequency
Hz
50
9. Type of cooling
ONAN
10. Type of bushing :
High voltage
Required
Low voltage
Required
11. Off load tap-changer :
Rated tap
kV
33
Tap range
%
+ 5 to 5
Number of taps
Taps
5
12. Impedance voltage at
%
Less than 4%
75deg C., at nominal ratio
and rated power
Temperature rise at rated
Required
power
(Max. ambient temp.: 40
Required
C)
13. - Oil by thermometer
deg.
60
C
14. Winding by resistance
deg.
65
measurement
C
15. Dimensions and Total
Required
Weight
16. Height x width x depth
mm
Required
17. Total weight
Kg
Required
18. Dimensions and Total
Required

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Weight
19. Period of time, equipment
has been in service
20. Period of time, equipment
has been under
manufacture

Part5-25

Years

Years

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(O) BATTERY AND BATTERY CHARGER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.N
o

Description

Unit

REB
Requirement

A. Battery
Required

Manufacturer name &


country

Installation

Indoor (self supporting


unit).

Type/Model

Nickel Cadmium Alkaline

Operating Voltage

Continuous discharge

Capacity (at the 5 hr rate)

No. of cell

Discharging voltage

Charging voltage (normal)

10

Charging voltage (max)

1.75 volts per cell

11

Type of container

Transparent plastic

12

Mounting

13

Construction

14

Standard

110 V, DC
20 A during 5 hour
100 A hour
90
1.3 - 1.5 volt per cell
1.55 - 1.65 volt per cell

Cabinet
Closed top
All equipment and
materials shall be
designed, manufactured
and tested in accordance
with the latest editions of
applicable IEC standard
unless other wise
specified in the
specification. Other
internationally acceptable
standards will also be
considered provided that
relevant values are at least
similar to those under IEC

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-26

standards.
15
16

Period of time,
equipment has been in
service
Period of time,
equipment has been
under manufacture

Manufacturer
country

Rectifier type

Nominal output voltage

name

Years

Years

B. Battery charger
Required
&
Silicon or Selenium
110 D.C

Input voltage

433 V (50 Hz) three


phases.

Charging operating control

Boost and floating charge,


automatic with manual
operation

Maximum charging current

As required

Provision constant current


15A - 40A

Required

Provision of constant
voltage charge 90V - 130V
Period of time, equipment
has been in service
Period of time, equipment
has been under
manufacture

Required

8
9
10

Year
s
Year
s

2
5

Section VI. Employers Requirements

Part5-27

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(P) MULTIFUNCTION POWER METER
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.N
o

Description

Unit

REB
Requirement

Reference standard

Required

Manufacturer
Manufacturer type
designation
Country of manufacturer

Required

3
4
5

CT secondary current
VT secondary
voltage
Configuration

Supply voltage

11

Analog output
Pulse output (Import,
Export)
Serial interface

12

Measured Parameters

10

13
14

Period of time,
equipment has been in
service
Period of time,
equipment has been
under manufacture

Required
Required
A

mm

3x1103V
4-wire unbalanced

Required
2
2

Years

Required
kV, A, p.f, kW,
kWh, kVA, kVARh,
2

Years

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-28

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(Q) TRANSFORMER DIFFERENTIAL PROTECTION RELAY
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.No

Description

Unit

REB
Requirement

Reference standard

Required

Required

Manufacturer
Manufacturer type
designation:
Two-winding
transformer
Country of manufacturer

Rated voltage

Auxiliary DC voltage

V DC

Dielectric test

kV

Serial interface

3
4

10

11
12

Required
Required
Required

Communication module:
Operating interface
(connection to PC)
Period of time,
Years
equipment has been in
service
Period of time,
Years
equipment has been
under manufacture

110 / 3
110
2
Required
Required
Required
2
5

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-29

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(R) RESTRICTED EARTH FAULT PROTECTION RELAY
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.N
o

Description

Unit

REB
Requirement

Reference standard

Required

Required

Manufacturer
Manufacturer type
designation
Country of manufacturer

Rated current

Rated voltage

110 / 3

Auxiliary DC voltage

V DC

110

Dielectric test

kV

2
Required

9
10
11

Communication module:
Operating interface
(connection to PC)
Period of time, equipment
has been in service
Period of time, equipment
has been under
manufacture

Required
Required

Required
Years

Years

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-30

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(S) OVERCURRENT AND EARTH FAULT PROTECTION RELAY
(If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.N
o

Description

Unit

REB
Requirement

Reference standard

Required

Required

Manufacturer
Manufacturer type
designation
Country of manufacturer

Rated current

Auxiliary DC voltage

Dielectric test

9
10

Communication module:
Operating interface
(connection to PC)
Period of time,
equipment has been in
service
Period of time,
equipment has been
under manufacture

Required
Required
A

V DC

110

kV

2
Required
Required

Years

Years

Bidders
Guaranteed
Values

Deviation
Yes/No

Section VI. Employers Requirements

Part5-31

TECHNICAL REQUIREMENT AND GUARANTEE SCHEDULE


(T) AUTOMATIC VOLTAGE REGULATION RELAY
( If the Answer to the Deviation Column is YES.Then an explanation shall be provided in
the schedule of deviations)
Failure to provide all of the information requested may lead to the rejection of the bid.
Sl.
No

Description

Unit

REB
Requirement

Reference standard

Required

Required

Manufacturer
Manufacturer type
designation
Country of manufacturer

Rated voltage

Auxiliary DC voltage

Dielectric test

9
10

Required
Required
V

110 / 3

V DC

110

kV

2
Required

Communication module:
Operating interface
(connection to PC)
Period of time,
Years
equipment has been in
service
Period of time,
Years
equipment has been
under manufacture

Required
2
5

Bidders
Guaranteed
Values

Deviation
Yes/No

Anda mungkin juga menyukai