Anda di halaman 1dari 31

Add 2G Neighbor Cell(ADD G2GNCELL)

Function
Use this command to add a 2G neighboring cell.
Note
None
Parameter
Parameter ID

Parame Parameter Description


ter
Name

IDTYPE

Index
Type

Meaning: Index type

GUI Value Range: BYNAME(By name),


BYID(By index), BYCGI(By CGI)

Actual Value Range: BYNAME, BYID, BYCGI

Unit: None

Default Value: None

Recommended Value: None


SRC2GNCELLID

Source
Cell
Index

Meaning: A cell Index must be unique in one BSC

Parameter ID

Parame Parameter Description


ter
Name
. It is used to uniquely identify a cell.

GUI Value Range: 0~2047

Actual Value Range: 0~2047

Unit: None

Default Value: None

Recommended Value: None


SRC2GNCELLNAME

Source
Cell
Name

Meaning: Name of a cell

GUI Value Range: None

Actual Value Range: 1~64 characters

Unit: None

Parameter ID

Parame Parameter Description


ter
Name
Default Value: None

Recommended Value: None


NBR2GNCELLID

Neighb
or 2G
Cell
Index

Meaning: Uniform number of a cell index within


a BSC
, which uniquely identifies a cell.

GUI Value Range: 0~5047

Actual Value Range: 0~5047

Unit: None

Default Value: None

Recommended Value: None


NBR2GNCELLNAME

Neighb
or 2G
Cell
Name

Meaning: Name of a cell

GUI Value Range: None

Parameter ID

Parame Parameter Description


ter
Name

Actual Value Range: 1~64 characters

Unit: None

Default Value: None

Recommended Value: None


SRCMCC

Source
Cell
MCC

Meaning: Mobile country code (MCC) of the


source cell

GUI Value Range: None

Actual Value Range: 1~3 characters

Unit: None

Default Value: None

Recommended Value: None

Parameter ID

Parame Parameter Description


ter
Name

SRCMNC

Source
Cell
MNC

Meaning: Mobile network code (MNC) of the


source cell

GUI Value Range: None

Actual Value Range: 1~3 characters

Unit: None

Default Value: None

Recommended Value: None


SRCLAC

Source
Cell
LAC

Meaning: Local area code (LAC) of the source


cell

GUI Value Range: 1~65533, 65535

Actual Value Range: 1~65533, 65535

Unit: None

Parameter ID

Parame Parameter Description


ter
Name
Default Value: None

Recommended Value: None


SRCCI

Source
Cell CI

Meaning: Source cell ID

GUI Value Range: 0~65535

Actual Value Range: 0~65535

Unit: None

Default Value: None

Recommended Value: None


NBRMCC

Neighb
our Cell Meaning: Mobile Country Code (MCC) of a
MCC
neighboring cell

GUI Value Range: None

Parameter ID

Parame Parameter Description


ter
Name
Actual Value Range: 1~3 characters

Unit: None

Default Value: None

Recommended Value: None


NBRMNC

Neighb
our Cell Meaning: Mobile Network Code (MNC) of a
MNC
neighboring cell

GUI Value Range: None

Actual Value Range: 1~3 characters

Unit: None

Default Value: None

Recommended Value: None

Parameter ID

Parame Parameter Description


ter
Name

NBRLAC

Neighb
our Cell Meaning: Local Area Code (LAC) of a
LAC
neighboring cell

GUI Value Range: 1~65533, 65535

Actual Value Range: 1~65533, 65535

Unit: None

Default Value: None

Recommended Value: None


NBRCI

Neighb
our Cell Meaning: Cell ID of a neighboring cell
CI
GUI Value Range: 0~65535

Actual Value Range: 0~65535

Unit: None

Parameter ID

Parame Parameter Description


ter
Name
Default Value: None

Recommended Value: None


SRCHOCTRLSWITCH

Current
HO
Meaning: Whether the currently used handover
CTRL algorithm in the source cell is HO Algorithm I or
Algorit HO Algorithm II
hm in
Source
Cell
GUI Value Range: HOALGORITHM1(Handover
algorithm I), HOALGORITHM2(Handover
algorithm II)

Actual Value Range: HOALGORITHM1,


HOALGORITHM2

Unit: None

Default Value: HOALGORITHM1

Recommended Value: HOALGORITHM1


INTERCELLHYST

Intercell HO Meaning: Hysteresis value during the handovers


Hystere between cells, This value is used to suppress pingsis
pong handovers between cells.

Parameter ID

Parame Parameter Description


ter
Name

GUI Value Range: 0~127

Actual Value Range: 0~127

Unit: dB

Default Value: 68

Recommended Value: In densely populated urban


areas, the recommended value is 68; in the
suburbs, the recommended value is 72.
MINOFFSET

Min
Access
Level
Offset

Meaning: Minimum receive level offset.


An MS can be handed over to a neighboring cell
only when the downlink level of the neighboring
cell is greater than the sum of Min DL level on
candidate Cell and the value of this parameter.

GUI Value Range: 0~63

Actual Value Range: 0~63

Parameter ID

Parame Parameter Description


ter
Name
Unit: dB

Default Value: 0

Recommended Value: 0
PBGTMARGIN

PBGT
HO
Meaning: PBGT handovers to a neighboring cell
Thresho are allowed only when the downlink level
ld
difference between the neighboring cell and the
serving cell is larger than this parameter. When
the value of this parameter is smaller than 64,
handovers to a neighboring cell with a lower level
than the current serving cell are allowed.

GUI Value Range: 0~127

Actual Value Range: 0~127

Unit: dB

Default Value: 68

Recommended Value: In densely populated urban


areas, the recommended value is 68; in the

Parameter ID

Parame Parameter Description


ter
Name
suburbs, the recommended value is 72.

BQMARGIN

BQ HO
Margin Meaning: If (downlink level of the neighbor cell
after filtering - downlink level of the serving
cell (after power control compensation)) >
(Inter-cell HO Hysteresis - BQ HO Margin +
64), the BQ handover to the neighbor cell is
triggered.

GUI Value Range: 0~127

Actual Value Range: 0~127

Unit: dB

Default Value: 69

Recommended Value: 69
ISCHAINNCELL

Chain
Neighb
or Cell

Meaning: Whether the cell is a chain neighboring


cell. The parameter is used in the quick handover
algorithm. Quick handover aims to increase the
handover success rate of an MS moving at a high
speed and to ensure the call continuity and low
call drop rate. Quick handover applies to the
scenario where an MS moves fast along an urban
backbone road, a selected route, or a high-speed

Parameter ID

Parame Parameter Description


ter
Name
railroad. The target cell must be a chain
neighboring cell.

GUI Value Range: NO(No), YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: NO

Recommended Value: NO
INTELEVHOHYST

Adjacen
t Cell
Interlayer
HO
Hystere
sis

Meaning: Hysteresis value during the handovers


between cells on different layers or of different
priorities. This value is used to suppress interlayer ping-pong handovers.

GUI Value Range: 0~127

Actual Value Range: 0~127

Parameter ID

Parame Parameter Description


ter
Name
Unit: dB

Default Value: 67

Recommended Value: 67
DRHOLEVRANGE

Directe
d Retry Meaning: Maximum signal level difference
Handov between the neighbor cell and the serving cell for
er Level triggering directed retry
Range
GUI Value Range: 0~128

Actual Value Range: 0~128

Unit: dB

Default Value: 72

Recommended Value: 72
IBCANCELLFLAG

IBCA
Neighb
or Cell
Flag

Meaning: Indicates whether this neighboring cell


is the IBCA neighboring cell of the serving cell.
That is, when a cell is configured as the

Parameter ID

Parame Parameter Description


ter
Name
neighboring cell of the serving cell, whether the
IBCA algorithm considers the interference
between the serving cell and the neighboring cell.

GUI Value Range: NO(No), YES(Yes)

Actual Value Range: NO, YES

Unit: None

Default Value: NO

Recommended Value: NO
IBCADYNCMEASURENCELL IBCA
ALLOWED
Dyn
Measur
e
Neighb
our Cell
Flag

Meaning: Whether to measure the IBCA neighbor


cells of the serving cell dynamically. If the
dynamic measurement is enabled, when a call
uses a channel, the BSC sends the SACCH
Modify message to modify the frequencies in the
BA2 table in System Information 5, 5bis, and 5ter
to the frequencies at which the IBCA neighbor
cells operate. Thus, the call measures and reports
only these frequencies to the BSC.

GUI Value Range: NO(No), YES(Yes)

Parameter ID

Parame Parameter Description


ter
Name
Actual Value Range: NO, YES

Unit: None

Default Value: NO

Recommended Value: Set this parameter to YES


for the neighboring cell with co-channel
interference and the neighboring cell that may
cause interference; set this parameter to NO for
other neighboring cells.
IBCARXLEVOFFSET

IBCA
RxLev
Offset

Meaning: Estimates the receive level of the


unmeasured IBCA neighboring cells. When a
consecutive IBCA Non Measurement Ncell
Stat. Num measurement reports cover less than
six neighboring cells (or the number of the
reported neighboring cells is smaller than that of
the actually configured neighboring cells), this
parameter is used to estimate the receive level of
the unmeasured IBCA neighboring cells. The
estimated value is IBCA Pathloss Est of Non.
MR Ncell. Otherwise, the signal strength of the
unmeasured IBCA neighboring cells is the signal
strength of the measured neighboring cells
(including non-IBCA neighboring cells)
subtracted by IBCA RxLev Offset.

GUI Value Range: 0~63

Parameter ID

Parame Parameter Description


ter
Name
Actual Value Range: 0~63

Unit: dB

Default Value: 4

Recommended Value: 4
CHAINNCELLTYPE

Chain
Neighb Meaning: This parameter indicates the
our Cell geographical relationship between the
Type
neighboring cell and the serving cell. In the BSC,
if direction A is selected, then the reverse
direction is B.

GUI Value Range:


QUICK_HO_NCELL_TYPE_A(QUICK_HO_N
CELL_TYPE_A),
QUICK_HO_NCELL_TYPE_B(QUICK_HO_N
CELL_TYPE_B)

Actual Value Range:


QUICK_HO_NCELL_TYPE_A,
QUICK_HO_NCELL_TYPE_B

Unit: None

Parameter ID

Parame Parameter Description


ter
Name
Default Value: QUICK_HO_NCELL_TYPE_A

Recommended Value:
QUICK_HO_NCELL_TYPE_A
EDGEADJSTATTIME

Edge
HO
AdjCell
Watch
Time

Meaning: According to the P/N rule, if a neighbor


cell meets the conditions for selecting the
neighbor cell for edge handover in P of N
measurement reports, the edge handover to the
neighbor cell is triggered.
This parameter specifies the number N.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 6

Recommended Value: 6
EDGEADJLASTTIME

Edge
HO
Meaning: According to the P/N rule, if a neighbor
AdjCell cell meets the conditions for selecting the

Parameter ID

Parame Parameter Description


ter
Name
Valid
Time

neighbor cell for edge handover in P of N


measurement reports, the edge handover to the
neighbor cell is triggered.
This parameter specifies the number P.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 4

Recommended Value: 4
LEVSTAT

Layer
HO
Watch
Time

Meaning: The triggering of inter-layer handovers


must meet the P/N criteria, that is, when the
condition for inter-layer handovers is met for a
consecutive P seconds during N seconds, an interlayer handover is triggered. This parameter
corresponds to the N in the P/N criteria.

GUI Value Range: 1~32

Parameter ID

Parame Parameter Description


ter
Name
Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 6

Recommended Value: 6
LEVLAST

Layer
HO
Valid
Time

Meaning: The triggering of inter-layer handovers


must meet the P/N criteria, that is, when the
condition for inter-layer handovers is met for a
consecutive P seconds during N seconds, an interlayer handover is triggered. This parameter
corresponds to the P in the P/N criteria.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 4

Parameter ID

Parame Parameter Description


ter
Name
Recommended Value: 4

PBGTSTAT

PBGT
Watch
Time

Meaning: The triggering of PBGT handovers


must meet the P/N criteria, that is, when the
condition for PBGT handovers is met for a
consecutive P seconds during N seconds, a PBGT
handover is triggered. This parameter corresponds
to the N in the P/N criteria.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 6

Recommended Value: 6
PBGTLAST

PBGT
Valid
Time

Meaning: The triggering of PBGT handovers


must meet the P/N criteria, that is, when the
condition for PBGT handovers is met for a
consecutive P seconds during N seconds, a PBGT
handover is triggered. This parameter corresponds
to the P in the P/N criteria.

Parameter ID

Parame Parameter Description


ter
Name
GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 4

Recommended Value: 4
BETTERCELLSTATTIME

Better
Cell HO Meaning: According to the P/N rule, if the
Watch conditions for the handover to a better cell due to
Time
interference are met for P seconds within N
seconds, the handover is triggered.
This parameter specifies the number N.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Parameter ID

Parame Parameter Description


ter
Name
Default Value: 6

Recommended Value: 6
BETTERCELLLASTTIME

Better
Cell HO Meaning: According to the P/N rule, if the
Valid
conditions for the handover to a better cell due to
Time
interference are met for P seconds within N
seconds, the handover is triggered.
This parameter specifies the number P.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 4

Recommended Value: 4
HOSTATICTIME

Quick
Handov Meaning: According to the P/N rule, if the
er Static conditions for fast handover are met in P of N
Time
measurement reports, the handover is triggered.

Parameter ID

Parame Parameter Description


ter
Name
This parameter specifies the number N.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Unit: s

Default Value: 4

Recommended Value: 4
HOLASTTIME

Quick
Handov Meaning: According to the P/N rule, if the
er Last conditions for fast handover are met in P of N
Time
measurement reports, the handover is triggered.
This parameter specifies the number P.

GUI Value Range: 1~32

Actual Value Range: 0.5~16, step:0.5

Parameter ID

Parame Parameter Description


ter
Name
Unit: s

Default Value: 3

Recommended Value: 3
HCSSTATTIME

HCS
HO
Watch
Time

Meaning: According to the P/N rule, if the


conditions for the handover to a different micro
cell due to fast movement are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number N.

GUI Value Range: 1~16

Actual Value Range: 0.5~8, step:0.5

Unit: s

Default Value: 3

Recommended Value: 3

Parameter ID

Parame Parameter Description


ter
Name

HCSLASTTIME

HCS
HO
Valid
Time

Meaning: According to the P/N rule, if the


conditions for the handover to a different micro
cell due to fast movement are met in P of N
measurement reports, the handover is triggered.
This parameter specifies the number P.

GUI Value Range: 1~16

Actual Value Range: 0.5~8, step:0.5

Unit: s

Default Value: 2

Recommended Value: 2
BQSTATTIME

BQ HO
Watch Meaning: According to the P/N rule, if the
Time
conditions for emergency BQ handover are met in
P of N measurement reports, the handover is
triggered.
This parameter specifies the number N.

GUI Value Range: 1~16

Parameter ID

Parame Parameter Description


ter
Name
Actual Value Range: 0.5~8, step:0.5

Unit: s

Default Value: 1

Recommended Value: 1
BQLASTTIME

BQ HO
Valid
Meaning: According to the P/N rule, if the
Time
conditions for emergency BQ handover are met in
P of N measurement reports, the handover is
triggered.
This parameter specifies the number P.

GUI Value Range: 1~16

Actual Value Range: 0.5~8, step:0.5

Unit: s

Default Value: 1

Parameter ID

Parame Parameter Description


ter
Name
Recommended Value: 1

TASTATTIME

TA HO
Watch
Time

Meaning: The P/N criterion must be met for


triggering a TA handover. That is, the TA
handover can be triggered only if P measurement
reports among N measurement reports meet the
triggering conditions. This parameter corresponds
to N in the P/N criterion.

GUI Value Range: 1~16

Actual Value Range: 0.5~0.8, step:0.5

Unit: s

Default Value: 1

Recommended Value: 1
TALASTTIME

TA HO
Valid
Time

Meaning: The P/N criterion must be met for


triggering a TA handover. That is, the TA
handover can be triggered only if P measurement
reports among N measurement reports meet the
triggering conditions. This parameter corresponds
to P in the P/N criterion.

Parameter ID

Parame Parameter Description


ter
Name
GUI Value Range: 1~16

Actual Value Range: 0.5~8, step:0.5

Unit: s

Default Value: 1

Recommended Value: 1
ULBQSTATTIME

UL BQ
HO
Static
Time

Meaning: The P/N criterion must be met for


triggering a UL BQ handover. That is, the UL BQ
handover can be triggered only if P measurement
reports among N measurement reports meet the
triggering conditions. This parameter corresponds
to N in the P/N criterion.

GUI Value Range: 1~8

Actual Value Range: 0.5~4, step:0.5

Unit: s

Parameter ID

Parame Parameter Description


ter
Name
Default Value: 1

Recommended Value: 1
ULBQLASTTIME

UL BQ
HO
Last
Time

Meaning: The P/N criterion must be met for


triggering a UL BQ handover. That is, the UL BQ
handover can be triggered only if P measurement
reports among N measurement reports meet the
triggering conditions. This parameter corresponds
to P in the P/N criterion.

GUI Value Range: 1~8

Actual Value Range: 0.5~4, step:0.5

Unit: s

Default Value: 1

Recommended Value: 1
LOADHOPBGTMARGIN

Load
HO
PBGT
Thresho
ld

Meaning: If the path loss in the serving cell minus


that in a handover candidate cell is not smaller
than the parameter value, the handover to the
candidate cell is allowed. The parameter loosens

Parameter ID

Parame Parameter Description


ter
Name
the requirement of the PBGT handover threshold
when the load of the serving cell reaches a certain
level. Some traffic that could not be handed over
to a neighboring cell through the PBGT handover
can be handed over now. The value "0" indicates
that the enhanced load handover to the
neighboring cell is not allowed.

GUI Value Range: 0~127

Actual Value Range: -64dB ~ 63dB

Unit: None

Default Value: 0

Recommended Value: 0

Example
To add a neighboring cell (IDTYPE = Index Type , Source Cell Name = Cell000,
Neighbor 2G Cell Name = cell002;
Inter-cell HO Hysteresis = 50; Min Access Level Offset = 60;
Adjacent Cell Inter-layer HO Hysteresis = 68), run the following command:
ADD G2GNCELL: IDTYPE=BYNAME, SRC2GNCELLNAME="Cell000",
NBR2GNCELLNAME="cell002", INTERCELLHYST=50, MINOFFSET=60, INTELEVHOHYST=68;

Anda mungkin juga menyukai