Contents

1 SUMMARY .......................................................................................................................................... 2
2 TECHNOLOGY SPECIFICATIONS ................................................................................................ 2
3 ATTENTIONS...................................................................................................................................... 2
4 INSTALLATION MANUAL ................................................................................................................ 3
5 OPERATING DESCRIPTION ........................................................................................................... 6

5.1 Keys and parts function ............................................................................................... 6


5.2 System configuration ................................................................................................... 7
5.3 Menu operation .............................................................................................................. 9
5.4 LASER DUST operating ............................................................................................. 17
6 REGULATIONS ON CONNECTING EXTERNAL GAS CIRCUIT ............................................ 20

6.1 Environmental monitoring ........................................................................................ 20


6.2 Range calibrating position ........................................................................................ 20
6.3 Zero calibrating position ........................................................................................... 20
7 INTRODUCTION TO WORKING PRINCIPLE OF MONITOR .................................................. 21

7.1 Sampling ........................................................................................................................ 21


7.2 Filter ................................................................................................................................ 21
7.3 Sample gas density analysis .................................................................................... 21
7.4 Data acquisition/digital filtering ............................................................................... 21
7.5 Dynamic data graphic display .................................................................................. 21
7.6 Data storage/inquiry/communication ..................................................................... 21
8 OPERATING POINTS ..................................................................................................................... 22

8.1 Sensor polarization ..................................................................................................... 22


8.2 Charging built-in lithium battery.............................................................................. 22
8.3 Calibrating and monitoring zero and range.......................................................... 22
9 ATTENTION ...................................................................................................................................... 23
10 GPRS IP MODE ............................................................................................................................. 23

10.1 Brief introduction of product.................................................................................. 23


10.2 Installation introduction .......................................................................................... 27
10.3 Configuration.............................................................................................................. 29
10.4 Data transfer test environment testing ................................................................ 45
10.5 Appendix...................................................................................................................... 46
11 SYSTEM SOFTWARE ................................................................................................................... 48

11.1 Introduction................................................................................................................. 48
11.2 Software Installation ................................................................................................. 49
11.3 Software Operating Instructions ........................................................................... 57
11.4 Frequently Asked Questions .................................................................................. 60

1 Summary
ZTD-AQA is one kind of new type air detecting apparatus produced by our company,
is capable of continuously detecting density of SO2, NO2, PM10 with imported
Ampere-type high-sensitivity electrochemical sensor and is characterized with wide
measuring range, long service life, easy operation and portability etc. It can be applied
to continuous monitoring on the ambient air quality of urban atmospheric environment,
forest area, factory region, roads, tunnels, and airport etc.

2 Technology specifications
Monitored
Parameter

Sulfur Dioxide
(SO2)

Nitrogen Dioxide
(NO2)

Laser Dust
(PM10)

Measuring Range

0-200010-9

0200010-9

010.00mg/m3

Resolution

110-9

110-9

0.001mg/m3

Sensor lifetime: 2 years


Sampling flow: 300ml/min (max)
Power supply mode: built-in lithium battery (DC15V)
External AC power supply (AC240V)
Type: ZTD-AQA
Error of indication: 5%
Operating temperature: 045

3 Attentions
3.1 If the portable monitor would not work normally when it turned on, please aging
the sensors at least 2 hours. Press TEST key, portable monitor enter into measure
status. Check the time and monitoring parameters are whether normally, if not please
restart the portable monitor again.
3.2 In the main monitoring interface, press Enter key would turn off and turn on
sample pump. The pump keeps 300ml/min during the monitoring.
3.3 The portable should be always in power supplying state (lithium battery or external
power supplying are both available). In full battery state, the portable monitor can
stand by for a week, shall be charge the battery every week (charging in monitor turn
on or turn off are both available, once plugging the external power then the portable
monitor begins to charge automatically), otherwise the portable monitor will not work.

If the lithium battery is consume all the power, need charge it at least 1 hour and then
turn on the monitor.
3.4 Away from fire and humidity.

4 Installation manual
The portable monitor takes one box package for used, frame easy to installed, and to
save space.
Packing listfigure 1
4.1 Installation frame (figure 2)
4.2 Monitor in box (figure 3)
4.3 Attention: sample pipe shall turn to plug in and pull out, avoid damaging O-ring.

Figure 1

Figure 2

Figure 3

5 Operating Description
5.1 Keys and parts function
1

11

12

13 14

20

19

7 3 8 9

15
18

16
17

Figure 5.1

Deeply color buttons are control laser dust, lightly color buttons are control gas
1 Main monitor screen
2 Laser dust monitor screen
3 DTU switch
4 Data
5 Test
6 Reset
7 Amendment
8 SELECT
9 CANCEL
10
ENTER
11
Setup
12
OK
13
DOWN
14
Delete/Clock
15
UP
16
Respectively
17
Print
18
Auto

10

19
20

Figure 5.2

APower
CSD card

BMain engine switch


Dflow meter

5.2 System configuration


5.2.1 Open the end cover, plug the SIM card in DTU, and disconnect the series
interface and the series interface of motherboard, then connect DTU series interface
with series interface of computer, turn on DTU switch, according to operation
description to configure DTU, turn off DTU after correct configured, disconnect the
series interface of computer, and connect DTU interface with motherboard, shown as
figure:

Figure 5.3

Figure 5.4

Figure 5.5

2 Turn on DTU, turn on main engine power, 10 seconds later the system complete
self-monitoring, enter into monitoring interface.

Welcome interface:

Welcome to use air quality monitoring!

1. Self-monitoring for 10 seconds enter into monitor main interface:

SO2

0.000

mg/m3

NO2

0.000

mg/m3

PM10

0.000

mg/m3

NOKEY

2012.01.01

00:00:00

2. Check the clock and parameters are whether work well, if abnormally, restart the
main engine.
3. If normally, press TEST to enter into laser dust work mode.
4. According to installation and operation description of upper machine software to
set software.
5. Complete these operations, system enter into monitoring mode.

5.3 Menu operation


Press SELECT above 3 seconds enter into main menu:

Zeroing
Calibrate
Display Curve
Memory Data
System Para

DOWN

UP

CANCEL

ENTER

Press the key of DOWN UP to move the cursor; press ENTER enter into the menu
chosen by user.
1.0Zeroing
As shown in figure 1.0

Select Zero-air Type


1SO2
2NO2

DOWN

UP

CANCEL

ENTER

Figure 1.0

Press DOWN UP to choose SO2, press ENTER key to enter interface of SO2 Zero
Adjustment.

1.1 SO2 Zero Adjustment


As shown in figure (Figure 1.1)

Press

Sad
Nad

OK for Start calibrate to Zero

1709
2034

CANCEL

ENTER

Figure 1.1

Attention: In figure 1.1 the data 1709 indicates SO2 acquisition signal.
Adjust zero by connecting zero air or nitrogen. During process of gas connection, you
can adjust SO2 zero by pressing ENTER key after stabilization of acquisition signal.
Upon completion of zero adjustment, return to previous page by pressing CANCEL
key.

10

1.2NO2 Zero Adjustment


Press DOWN UP to choose NO2, press ENTER key to enter interface of NO2 Zero
adjustment.
Operating process as same as that of SO2, Perform NO2 zero adjustment by pressing
ENTER key. Return by pressing CANCEL key after zero adjustment.
2.0Calibrating
As shown in figure (Figure 2.0)

Select Std.-air Type


1 SO2
2 NO2

DOWN

UP

CANCEL

ENTER

Figure 2.0

Press DOWN UP to choose SO2, press ENTER key to enter interface of SO2 Calibrate
adjustment.
2.1 Calibrating SO2

Standard Gas Concentration:

2000.00
(Please put into Standard Gas,
Then press OK)

SELECT

DOWN

UP

CANCEL

ENTER

Figure 2.1

According to the calibrating gas density to set the parameter, pressing DOWN UP
key to increase or decrease the volume.

11

Can librate Span Now


Sad 2013
Nad 1456

CANCEL

ENTER

Figure 2.2

Input calibration gas and waiting for the gas density is reach to 2013 (see Figure2.2),
Press ENTER key to finish calibration. Repeat the same operation to calibrate again.
At last press CANCEL key to return main menu.
2.2Calibrating NO2
The operation is the same to calibrate SO2.
3.0Display monitoring curve
As shown in figure (Figure 3.0)

Display Curve
SO2
NO2
PM10

DOWN

UP

CANCEL

ENTER

Figure 3.0

Press DOWN UP to select SO2, press ENTER to enter next screen.

12

3.1 Curve of SO2

500PPB

SO2

t/s

Figure 3.1

As shown in figure, SO2 density measured every two seconds is within 90ppb
indicated in curve, which also shows data oscillation and stabilization.
NO2curve is display as the same way as SO2.
3.2 Curve of PM10/PM2.5

1mg/m3
PM10

t/s

Figure 3.2

After checking the data curve, return to main menu by pressing CANCEL key.
4Memory Data

13

NO.01
HISTORICAL Data Query Module
Hours data report
Day data report

DOWN

UP

CANCEL

ENTER

Figure 4.0

Press DOWN UP to select ENTER to enter next screen.

NO.01
05,12,17,01:20:00 CO 001.5;SO2 0.023;NO2 0.025;P 0.020;PPP 0.020;
05,12,17,01:20:00 CO 001.5;SO2 0.023;NO2 0.025;P 0.020;PPP 0.020;
05,12,17,01:20:00 CO 001.5;SO2 0.023;NO2 0.025;P 0.020;PPP 0.020;

DOWN

UP

CANCEL

ENTER

Figure 4.1

5System management
As shown in figure (Figure 5.0)

System Paramter
SETUP Para
VIEW Para

DOWN

UP

CANCEL

Figure 5.0

Press DOWN UP to select ENTER to enter next screen.


5.1 Parameter Setting
As shown in figure (Figure 5.1)

14

ENTER

Setup Para
Set Address
Memory Date
Set Time
Toggle Units
Internal para. Adjustment

DOWN

UP

CANCEL

ENTER

Figure 5.1

Press DOWN UP to select ENTER to enter next screen.

A Setting address
As shown in figure (Figure 5.1.1) enter into setting address interface

Set Address : 01

DOWN

UP

CANCEL

ENTER

Figure 5.1.1

Press DOWN UP to set station; press ENTER to save setting and return to upper
menu; press CANCEL to return to upper menu without save.

B Data Saving
As shown in figure (Figure 5.1.2) enter into data saving interface

15

Memory Data

DOWN

ON/OFF

UP

CANCEL

ENTER

Figure 5.1.2

Press DOWN UP to select ON/OFF, open or close memory data function; press
ENTER to save setting and return upper menu, press CANCEL to return upper
menu without save.

C Setting Time and Date


As shown in figure (Figure 5.1.3)

2012, 01, 22, Sunday 11:00:00


2012, 01, 22, Sunday 11:00:00
SELECT

DOWN

UP

CANCEL

ENTER

Figure 5.1.3

Press the SELECT to move cursor. Press DOWN UP to modify the selected
number. Press ENTER to save setting. Press CENCEL to enter to system
parameter management main interface after setting success. (Figure 5.0)

D Setting Unit
As shown in figure (Figure 5.1.4)

16

NO.01

Select Units :mg/m3

DOWN

UP

/ppb/ppm

CANCEL

ENTER

Figure 5.1.4

5.2 View Parameter


As shown in figure (Figure 5.2)

CO

SO2

NO2

Zero:

1003

1565

2989

Span:

2215

3343

0560

bq:

1510

2220

2220

gas:

0038

0097

0076

1579

2920

ad:

0042

A 0.768

B 0.750

C 0.153

D 1.189

CANCEL

Figure 5.2

Figure 5.2 is display Zeroing and calibration data. Press CANCEL to return back to
Figure 5.0.

5.4 LASER DUST operating


(1) Start-up:
Connect powerand turn on the instrument, and then the screen displays:
Laser dust monitor
Please wait
The information above disappears about 2 seconds later and the screen displays the
main interface: please operate. This represents that the instrument has started up
successfully.
If the time on screen is correct, users press the TEST button to approach monitoring
status.
If the monitor would work normally then do not do the operations as below.

17

(2) Correct the clock


Press clock key once and appears around the year. Press to revise the year.
After year is corrected, press to move cursor to the month. Correct the date,
hour and minute in the same way.
Press Confirm to confirm this operation. The correct time is saved in the chip of
micro-processor. It is necessary to modify the clock after many times of measuring.
(3) Calibrate automatically
This function is used for micro-processor to judge working status of internal circuit.
Steps: when the screen displays: please operate, users press calibrate automatically
key to start to calibrate.
At that time, the screen displays: calibrating
If calibration is done successfully, the screen will display calibration is over after one
minute. Or the screen displays: Since the school wrong, check.
If since the school fails, micro-processor cannot correct the measuring error of the
instrument and the measuring accuracy cannot be ensured.
Press reset key to return to the main interface of please operate.
(4) Measure
A Prepare:
Choose test item
a, Press Select and the screen displays Measurement period set XX, this value is
the times of the sampling times in a periodpress to modify the value. For
example, this value is 03, and then the instrument will display average value,
environmental temperature, and environmental humidity after 3 sampling. The data is
saved in memory.
b, After sampling period is set, users press Confirm and the screen displays:
Sampling time setting 01 minutes. This is the default sampling time. Users can press
to alter the value.
c, After sampling time is set, press Confirm, then the screen displays: metric/English
size setting. The default is metric sizeEnglish size is used in measuring
particulates quantity only.
dPress Confirm and the screen display Print Settings. The default is Manual.
ePress Confirm and the screen display Test mode. The default isPM10PM2.5.
Press to select other options.
fPress Confirm to return to the main interface.
BStart to measure
When there is no operation in a minute after start-up, the instrument enters measuring
status automatically, and the screen displaysPM10 measurements which is the
concentration of the PM10 at present. When sampling time is over, the instrument
stops counting and resample after 10 seconds.
If the preset sampling times is 3, the screen will display the average value,
temperature, and humidity of the 3 sampling. Then the next sampling period begins.
5 Data enquiry

18

When the screen displays please operate,press reset key to return to the main
interface, press data key, the screen displays the newest data:
xx-xx store data
PM10 test value 0.xxx mgM3
PM2.5 test value 0.xxx mgM3
Temperature XX
Humidity XXBH
ln xx Year xx month xx day xx : xx ..
xx-xx is Area xx, Group xx. Press to search the groups in current Area.
Press to search area. Press reset key to return to main interface.
If the measuring item is particulate quantity, then the data displayed is:
xx-xx store data
xxxxxx tablets/liter
ln xx Year xx month xx day xx : xx ..
Particulate quantity is the measuring value of 0.5um of particles.
(6) Delete
When memory is full 800 groups data, the main interface displays memory is full
and data cannot be saved. Then users must delete obsolete data to save memory
space.
Steps:
When the screen is displays the saved data, press to select the data number.
And then press delete, the screen displays:
Press delete to delete the data
Press confirm to cancel operation
Press delete and the data numbers before the selected data number will be all
deleted. The remaining data numbers will be arrayed from 1.
Press confirm to cancel operation and return to the interface displaying data.
For example: the instrument has saved 80 groups data (4 areas):00-01,03-20, the
screen displays:
0320 store data
PM10 test value 0.xxx mgM3
PM2.5 test value 0.xxx mgM3
Temperature XX
Humidity XXBH
ln xx Year xx month xx day xx : xx ..
If users want to delete the data in former 2 areas(40 groups data), you can press
key to move the cursor to 0120, and then press delete key. The screen displays:
Press delete to delete the data
Press confirm to cancel operation
Press the delete again, the screen displays:
0120 store data
PM10 test value 0.xxx mgM3
PM2.5 test value 0.xxx mgM3
Temperature XX

19

Humidity XXBH
ln xx Year xx month xx day xx : xx ..
The information above means the former 2 areas have been deleted and 0320
groups become 0120.
(7) Reset
Users can press reset key to return the main interface: please operate.
(8) Communication link
Connect the print output port in the back panel of the instrument and upper computer
with 9 core cable, connect the print output of the back panel with upper computer
input is work well .
Then the instrument becomes a lower machine which can communicate with upper
computer. During communication, measuring data is saved and transmitted to upper
computer automatically.
(9) Turn off
When the batteries are full charged, it can supply electricity to the instrument for 5
hours. When battery voltage is low, the low-voltage protection circuit will cut down the
power automatically and users should charge the instrument in time.
Charging method: insert the charger plug into charging place for 8 hours.
When the instrument uses AC, the batteries are charged at the same time.

6 Regulations on connecting external


gas circuit
6.1 Environmental monitoring
The monitor collects sample air from CO\SO2\NO2 inlet for analysis.

6.2 Range calibrating position


When calibrating range of CO\SO2\NO2 sensor, standard range gas is required to
be input from CO\SO2\NO2 inlet and is to be exhausted from CO\SO2\NO2 air
outlet after being analyzed with apparatus.
When calibrating the monitor range, it is required to introduce the gas exhausted
from air outlet to safe place so to guarantee personnel security.

6.3 Zero calibrating position


When calibrating zero of CO\SO2\NO2 sensor, zero air is required to be input from
CO\SO2\NO2 inlet and is to be exhausted from CO\SO2\NO2 air outlet after being
analyzed with apparatus.

20

7 Introduction to working principle of


monitor
The monitor consists of parts involving sampling, filter, sample gas decrease
humidity/constant temperature control, sample gas density analysis, data
acquisition/digital filtering, dynamic data graphic display, data
storage/inquiry/communication and automatic power supply mode selection etc.

7.1 Sampling
The sampling part consists of air line, filter, suction pump and flow regulator etc. In
this part, the ambient air is introduced by suction pump through the filter and delivered
to sensor air chamber before being exhausted via monitor discharge hole as per flow
of 300mL/min separately.

7.2 Filter
Zero air filters: filter the sample gas when calibrating the zero.
Dust removal filter: remove dust particles in sampling gas.

7.3 Sample gas density analysis


It is made up of such electrochemical sensors as SO2 sensor etc. These sensors
detect the density of sample gas flowing through air chamber and output the current
signal corresponding to density of measured gas.

7.4 Data acquisition/digital filtering


The CPU-controlled data acquisition circuit collects multiplexed signals output by the
sensors instantly and processes the abnormal data with digital filtering so to ensure
correct and reliable acquired data against eliminating influences of various
interferences.

7.5 Dynamic data graphic display


The monitor applies 640480 dpi graphic LCD, which can visually display various
monitoring data and figure as well as monitor working status and provide Chinese or
English menu in man-machine dialogue with friendly interface.

7.6 Data storage/inquiry/communication


Adopt large-capacity data storage, capable of storing one months historical
monitoring data. Provide easy data inquiry. Equipped with CPRS communication

21

interface, through which you can achieve communication with computer, data
collection and printing.

8 Operating points
If lower-position computer needed save data manually, make sure SD card is connect
well before setting, turn off monitor first then take SD card in or out; SD card memory
is 512M, if memory is not enough, please delete trashy data, avoid to error when save
data.

8.1 Sensor polarization


To satisfy requirements for normal operation, the monitor shall always keep the
sensor in polarized state. When the sensor has been replaced or the polarization
process has been interrupted, you can calibrate or measure the monitor only after
24-hours continuous sensor polarization.
The monitor is equipped with built-in lithium battery (15V). When the external power
supply fails to provide power for the monitor, it will automatically switch to battery to
provide polarizing voltage for sensor. Under conditions of normal operation, the
lithium battery shall be ensured with sufficient electricity so to keep the sensor always
in polarized state.

8.2 Charging built-in lithium battery


The monitor is supplied with built-in lithium battery or external AC mains. When being
connected to external mains, it will automatically shut off the built-in battery.
When the lithium battery needs to be charged, it can be in charging state through
inserting the power plug into the socket without opening the power supply switch.

8.3 Calibrating and monitoring zero and range


The monitor can only be calibrated and monitored after at least 24 hours continuous
polarization.
8.3.1 Calibrating zero
The sample gas for calibrating zero can adopt zero calibrating standard gas or clean
ambient air. Connect the monitor to the zero calibrating filters and perform calibration
as per instructions displayed in screen. See attached Figure II.
Fill the high-purity nitrogen into gas bag. Note that the gas bag shall not contain other
residual gases otherwise it will influence the accuracy of calibration.
8.3.2 Calibrating range

22

When calibrating range, adjust the standard gas flow at 300ml/min and operate as per
instructions displayed in screen.
See attached Figure III.
(1) First, fill high-purity nitrogen and standard gas into gas bag separately.
(2) Prepare standard-proportion gas with high-accuracy gas mixer (See Operational
Instructions for Gas Mixer).
(3) Inlet the prepared standard-proportion gas into air-inlet opening and perform
calibration.
Attention: please dont calibration sensor if monitor is available, or inlet high density
calibration gas due to sensor goes back normal monitoring status need long time.
8.3.3 Environmental monitoring
When perform environmental monitoring, locate the monitor in the monitored
environment or connect the air-inlet opening to sampling pipe and operate as per
instructions displayed in screen. Properly connect AC220V power supply.

9 Attention
1. The monitor shall be protected from rain or moisture.
2. Never operate or calibrate the monitor at places close to EMI source.
3. The sensor contains acid solution and do not damage it when replacing. In case of
acid solution in the sensor leaking to your skin due to improper operation, you should
flush your skin with running water for ten minutes promptly and then get for medical
assistance in time.
4. Never repair or disassemble the monitor without permission. If the monitor fails or
the sensor expires, we will provide you with high-quality after-sales technical service.

10 GPRS IP MODE
10.1 Brief introduction of product
10.1.1 General
F2X03 series GPRS IP MODEM is a kind of cellular terminal device that provides data
transfer function by public GPRS network.

23

It adopts high-powered industrial 16/32 bits CPU and embedded real time operating
system. It supports RS232 and RS485 (or RS422) port that can conveniently and
transparently connect one device to a cellular network, allowing you to connect to
your existing serial devices with only basic configuration.
It has been widely used on M2M fields, such as intelligent transportation, smart grid,
industrial automation, telemetry, finance, POS, water supply, environment protection,
post, weather, and so on.

10.1.2 Features and benefits


Design for Industrial Application
High-powered

industrial cellular module


High-powered

industrial 16/32 bits CPU


Support

low-consumption mode, including sleep mode, scheduled online/offline


mode, scheduled power-on/power-off mode (optional)
Housing:

iron, providing IP30 protection.


Power

range: DC 5~35V
Stability and Reliability
Support

hardware and software WDT


Support

auto recovery mechanism, including online detect, auto redial when offline
to make it always online
RS232/RS485/RS422

port: 15KV ESD protection


SIM/UIM

port: 15KV ESD protection


Power

port: reverse-voltage and overvoltage protection


Antenna

port: lightning protection (optional)


Standard and Convenience
Support

standard RS232 and RS485 (or RS422) port that can connect to serial
devices directly
Support

intellectual mode, enter into communication state automatically when


powered
Provide

management software for remote management

24

Support

several work modes


Convenient

configuration and maintenance interface


High-performance
Support

TCP server and support multi TCP client connection (optional)


Support

double data centers, one main and another backup


Support

multi data centers and it can support 5 data centers at the same time
Support multi online trigger ways, including SMS, ring and data. Support link
disconnection when timeout
Support

dynamic domain name (DDNS) and IP access to data center


Design

with standard TCP/IP protocol stack


Support

APN/VPDN
10.1.3 Working principle
The principle chart of the IP MODEM is as following:

10.1.4 Specifications
F2x03 series wireless parameters
Item
Cellular
Module
Standard and
Band

Bandwidth
TX power
RX sensitivity

Content
Industrial cellular module
EGSM900/GSM1800MHz,
GSM850/900/1800/1900MHz(optional)
Compliant to GSM phase 2/2+
GPRS class 10, class 12(optional)
85.6Kbps
GSM850/900: <33dBm
GSM1800/1900: <30dBm
<-107dBm

25

Hardware System
Item
Content
CPU
Industrial 16/32 bits CPU
FLASH
1MB(Extendable)
SRAM
512KB(Extendable)
Interface Type
Item
Serial

Indicator
Antenna
SIM/UIM
Power

Power Input
Item
Standard
Power
Power Range
Consumption

Content
1 RS232 port and 1 RS485(orRS422) port, 15KV ESD
protection
Data bits: 5, 6 ,7, 8
Stop bits: 1, 1.5, 2
Parity: none, even, odd, space, mark
Baud rate: 110~230400 bps
"Power", "ACT", "Online"
Standard SMA female interface, 50 ohm, lighting
protection(optional)
Standard 3V/1.8V user card interface, 15KV ESD
protection
Standard 3-PIN power jack, reverse-voltage and
overvoltage protection

Content
DC 12V/1.5A
DC 5~35V
<250mA (12V)

Physical Characteristics
Item
Content
Housing
Iron, providing IP30 protection
Dimensions
91x58.5x22 mm

26

Weight

205g

Environmental Limits
Item
Content
Operating
-25~+65C-13~+149
Temperature
Extended
-30~+75C-22~+167
Operating
Temperature
Storage
-40~+85C-40~+185
Temperature
Operating
95% ( Non-condensing)
Humidity

10.2 Installation introduction


10.2.1 General
The IP MODEM must be installed correctly to make it work properly.
Warning: Forbid to install the IP MODEM when powered!
10.2.2 Encasement list
For safe transportation, IP MODEM usually is needed reasonable package, when you
open the package please keep the package material, for reuse.
Name
IP MODEM host
Mobiles Vehicle Antenna
SMA male
Power adapter
RS232 data cable
Manual CD

Quant
Remark
ity
1
Package depends on order
1
1
1
1

optional

10.2.3 Installation and cable connection


IP MODEM is encapsulated in metal box, would use indecently, two sides have fixed
holes, easily to installed, detail dimension (unit: mm)

27

Installation of antenna:
Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM
tightly. Warning: The antenna must be screwed tightly, or the signal quality of antenna
will be influenced!
Installation of cable:
Insert DB9F end of the RS232/RS485 data cable into the DB9M interface of IP
MODEM, and connect the other end with users device.
The signal connection of the RS232 data cable is as follows:

IP MODEM

User terminal

IP MODEM

DB9 famale

(DB9 famale

DB9 famale

1
RXD 2
TXD 3
4
GND 5
6
7
8
9

1
2 RXD
3 TXD
4
5GND
6
7
8
9

Interface:RS23
2

1
2
3
4
5
A 6
7
8
B 9

User terminal

ARed

BBlack
Interface:RS48
5

28

10.2.4 Power
The power range of the IP MODEM is DC 5~35V
Warning: When we use other power, we should make sure that the power can supply
power above 4W.
We recommend user to use the standard DC 12V/0.5A power adaptor.
10.2.5 Indicator lights introduction
The IP MODEM provides three indicator lights: Power, ACT, Online.
Indicator Light

State

Introduction

Power

ON

IP MODEM is powered on

OFF

IP MODEM is powered off

BLINK

Data is communicating

OFF

No data

ON

IP MODEM has logged on network

OFF

IP MODEM hasnt logged on network

ACT
Online

10.3 Configuration
10.3.1 Configuration connection
Before configuration, its necessary to connect the IP MODEM with the configure PC
by the shipped RS232 or RS232-485 conversion cable as following.

10.3.2 Configuration introduction


There are two ways to configure the IP MODEM:
Configuration

software tool: All the settings are configured through the shipped
software tool. Its necessary to have one PC to run this tool.
Extended

AT command: All the settings are configured through AT command, so


any device with serial port can configure it. Before configuration with extended AT
command, you should make IP MODEM enter configure state.

29

The steps how to make IP MODEM enters configure state, please refer to appendix.
The following describes how to configure IP MODEM with the configure software tool.
At the same time, it gives out the corresponding AT command of each configuration
item.
10.3.3

Run the configure tool: IP Modem Configure.exe

The Serial Parameters column shows the current serial port settings. To configure IP
MODEM, please choose the correct serial port which connects to IP MODEM, and the
baud rate is 115200 with no parity, then open the serial port. If the button text is
Close, it shows the serial port now has been opened. If the text is Open, you
should open the port first. When the port opened, the Output Info column will display
Port (COM1) Has OpenedPlease Re-Power the IP MODEM, Waiting IP MODEM
Enter Configure State...
10.3.4 Re-power IP MODEM

30

After Re-power IP MODEM, The configure tool will make it enter configure state. At
the same time, the software will load current settings from IP MODEM and displays on
the right configure columns. Its now ready to configure.
10.3.5 Configuration
10.3.5.1 Data service center settings
Settings on this page are the parameters related to Data Service Center (DSC).
Data

Center Number
IP MODEM supports two Data Service Center methods to transmit data.
Main and Backup: IP MODEM always tries to connect with the Main DSC. If fails to
connect with Main DSC, it will connect with Backup DSC at once
NoteIf no Backup DSC exists, please configure the Backup DSC same as Main
DSC.
Multi Data Service Center: IP MODEM can connect with at most five DSC at the same
time. All the multi DSC can receive the same application data.

If the Data Center Number is 1, IP MODEM work in Main and Backup DSC method.
When Data Center Number is greater than 1, IP MODEM works in Multi Data
Service Center method

31

AT command:
AT+SVRCNT=x
x: Data Service Center number
Note: every AT command is terminated with a enter character.
Main

Center Addr + Port:


IP Address and Port of the Main DSC, Its better to set the port greater than 1024.
AT command of the Main DSC IP address or domain name:
AT+IPAD=xxx
xxx: The IP address or domain name.
AT command of the Main DSC port:
AT+PORT=xxx
xxx: The port value
Backup

Center Addr+Port:
IP address and port of the Backup DSC

AT command of the Backup DSC IP address or domain


AT+IPSEC=xxx
xxx: The IP address or domain name
AT command of the Backup DSC port
AT+PTSEC=xxx
xxx: The port value
Multi

DSC Configuration

32

When Data Center Number is greater than 1, this setting is valid. For example
setting the Data Center Number as 3, Main Center, 2nd Center, 3rd Center work as
these three DSC
AT Command of the 2~5 DSC IP address or domain name
AT+IPADn=xxx
n is 1~4 correspond to center 2~5
xxx: The IP address or domain name
AT Command of the 2~5 DSC port
AT+PORTn=xxx
n is 1~4 correspond to port of center 2~5
xxx: The port value
Example:
Set IP address of center 3 as 166.111.8.238, and port

5001, the AT command is as

following:
AT+IPAD2=166.111.8.238
AT+PORT2=5001
Main

and Backup Center DNS Server

When the DSC Internet access uses domain name, Its necessary to set DNS server
resolving the DSC domain name. When the Data Center Number is 1, Main and
Backup Center DNS Server is used to resolve the Main center and Backup center
correspondingly.
AT command of Main Center DNS server:
AT+DNSSVR=aaa.bbb.ccc.ddd
aaa.bbb.ccc.ddd: The DNS server IP address(must be IP address.
AT command of Backup Center DNS server:

33

AT+DNSSV2=aaa.bbb.ccc.ddd
aaa.bbb.ccc.ddd: the DNS server IP address
Center

2~5 DNS Server

When the IP MODEM work in Multi Data Service Center method and the centers use
domain name, 2~5 DNS server is used to resolve center 2~5 correspondingly.
AT command of 2~5 DNS Server
AT+DNSSVRn=aaa.bbb.ccc.ddd
n is 1~4 correspond to center 2~5 DNS server.
aaa.bbb.ccc.ddd is the DNS server IP address
aaa.bbb.ccc.ddd is DNS service IP address (Must be IP address).
10.3.5.2 IP MODEM Parameter setting
IP
MODEM Work Mode

According to different application requirements, there are several protocol workmode


to choose.
PROTHeartbeat packet with TCP protocol, Data transmission with TCP protocol,
heartbeat packet and application data transmission are in the same TCP connection.
TRNSIP MODEM work as a common GPRS MODEM, It can be used in SMS, CSD,
dial-up applications.
TTRNHeartbeat packet with UDP protocol, Data transmission with TCP protocol
TLNTIP MODEM work as a telnet client

34

LONGHeartbeat packet with UDP protocol, Data transmission with TCP protocol, It
can transmit at most 8192 bytes data one time through extra application protocol.
LNGTHeartbeat with UDP protocol, Data transmission with TCP protocol, It can
transmit at most 8192 bytes data one time through extra application protocol.
TUDPHeartbeat with UDP protocol, Data transmission with UDP protocol, Heartbeat
packet and application data are in the same UDP connection.
TCSTUser can set custom register and heartbeat string, Data transmission with TCP
protocol.
AT command:
AT+MODE=xxxx
xxxx:

one of the above workmode

Trigger

Type

Normally, IP MODEM always keeps online and always be ready for data transmission.
But in some circumstances, its important to reduce wireless data flow. To realize this
function, the software can makes IP MODEM into sleep state in idle time. When there
is application data to transmit, IP MODEM can be triggered online ready for data
transmission. There are total five methods to make IP MODEM online:
AUTO: IP MODEM always keeps online
SMSD: send a special short message to make IP MODEM online
CTRL: make IP MODEM online through a phone call to IP MODEM
DATA: send special serial data to make IP MODEM online
MIXD: the combination of SMSD, CTRL, DATA. IP MODEM will be online when meet
one of these three trigger methods.
AT Command:
AT+ACTI=xxxx
xxxx:

one of the above trigger methods

Debug

Level

35

Debug information is used to debug software when there is software problem.


0 --- no debug information output
1 --- simple prompt information output
2 --- detail debug information output
AT Command:
AT+DEBUG=x
x : the debug level value
Note: Only there is some problem to the IP MODEM, Its necessary to set this value
as 2, in normal applications, this value should set to 0 or 1, the default value is 1.

Data

bit, Parity, Stop bit

8N1 --- 8 Databit, No parity, 1 Stopbit


8E1 --- 8 Databit, Even parity, 1 Stopbit
8O1 --- 8 Databit, Odd parity, 1 Stopbit
AT Command:
AT+SERMODE=xxx
xxx: one of the above serial mode
Communication

Baud rate
110

--- 110 bps

300

--- 300 bps

600

--- 600 bps

1200

--- 1200 bps

2400

--- 2400 bps

4800

--- 4800 bps

9600

--- 9600 bps

36

14400

--- 14400 bps

19200

--- 19200 bps

38400

--- 38400 bps

56000

--- 56000 bps

57600

--- 57600 bps

115200

--- 115200 bps

AT Command:
AT+IPR=xxx
xxx : one of the above baud rate

Device

ID

The identity number of IP MODEM, the value should be 8 bytes hex-decimal


characters.
AT Command:
AT+IDNT=aabbccdd
aabbccdd: the identity number of IP MODEM
SIM

Card No

The phone number of the SIM card .


AT Command:
AT+PHON=xxxxxxxxxx
xxxxxxxxxxx: the SIM card phone number
Bytes

Interval

37

The time interval used to determine whether the serial data frame transmission has
completed, IP MODEM will send the serial data to the center when two bytes transmit
time interval larger than this item value.
AT Command:
AT+BYTEINT=xxx
xxx: bytes interval time valuemillisecond
Custom

Register String

This item is only valid when the Work Mode is TCST. Its the self defined register
string. It can be empty, the maximum length is 70 bytes.
AT Command:
AT+CONNRGST=xxx
xxxself defined register string

Custom Heartbeat String

This item is only valid when the WorkMode is TCST. Its the self defined heartbeat
string, It can be empty, the maximum length is 70 bytes.
AT Command:
AT+LINKRGST=xxx
xxxself defined heartbeat string
Connect

Retry Times, Reconnect Time Interval

38

In normal applications, IP MODEM will always try to connect with the center even if
the center has problems or closed. To reduce these unnecessary wireless data flow,
you can configure the Connect Retry Times and Reconnect Time Interval items.
When IP MODEM fail to connect to the center with the configured Retry Time, It will
sleep Reconnect Time Interval time, then start next retry.
Connect Retry Times AT Command:
AT+RETRY=xxx
xxxtimes try to connect to the center
Reconnect Time Interval AT Command:
AT+RDLWT=xxx
xxx:

the sleep time until next retry.

Transfer

meaning

0 --- Yes, enable transfer meaning


1 --- No, disable transfer meaning
This item is only valid when the Work Mode is PROT. If this item is set to 0, IP
MODEM will transfer meaning to 0xfd and 0xfe. To know detail transfer meaning
method, please refer <<IP MODEM Transfer Meaning Explanation In the PROT work
mode>>. If this item is set to 1, all the transmission is transparent.
AT Command:
AT+STRAIGHT=x
X: 0 or 1

10.3.5.3 Other settings

39

Network

Attention:GPRS is wireless network : APN is (China mobile); cmnetChina Unicom


uninetuser name and password is empty; dial center number: *99***1#
CDMA is wireless network: APN is empty; user name and password both are
card; dial center number: #777
TD-SCDMA is wireless network: APN is cmnet ; user name and password is
empty; dial center number: *99***1#
WCDMA is wireless network: APN is 3gnet; user name and password is
spaced; dial center number: *99#
CDMA2000 1X EVDO is wireless network: APN is empty; user name and
password is spaced; dial center number: card; dial center number: #777
APN:
access point name.
Username: username to login the ISP network.
Password:
password to login the ISP network
Call Center: the call center phone number
AT Command of APN:
AT+APN=xxxx
xxxx: access point name
AT Command of Username:
AT+USERNAME=xxx
xxx username
AT Command of Password:
AT+PASSWORD=xxx
xxx password
AT Command of Call Center:
AT+CENT=xxx
xxx: call center phone number of

ISP

SMS Center

40

Your local SMS center number


AT Command:
AT+SMSC=xxx
xxx: your local SMS center number
Heartbeat Interval

Time interval sent heartbeat packet. (unit is second)


AT Command:
AT+POLLTIME=xxx
xxx: heartbeat packet time interval
Call Trigger Phone No

This item is only valid when the Trigger Type is CTRL or MIXD. In this trigger type,
IP MODEM will keeps in idle state until it receives the trigger phone call, then it will
connect to the center.
AT Command:
AT+CTRLNO=xxx
xxx: trigger phone number
Attention: trigger phone number is empty, triggered is success with any dial in. Device
must with caller ID display service.
SMS Trigger Password

This item is valid only when the Trigger Type is SMSD or MIXD, IP MODEM will
keeps in idle state until it receives the trigger short message, and then it will connect
to the center.

41

AT Command:
AT+SMSDPSWD=xxx
xxx : SMS content to trigger IP MODEM online
Attention: with SMSD, password shall set 4 letters by user. Send message: dial +
password; when password is empty, send message is dial.

Data Trigger Password

This item is valid only when the Trigger Type is DATA or MIXD, IP MODEM will
keeps in idle state until it receives the trigger on data, then it will connect to the center,
It will return to the idle state when receives trigger off data.
AT Command of Data Trigger On Password:
AT+DONPSWD=xxx
xxx : data trigger on password
AT Command of data trigger off password:
AT+DOFFPSWD=xxx
xxx :data trigger off password
TCP MTU

The maximum transmission unit of TCP packet


AT Command:
AT+TCPMTU=xxx
xxx : the MTU value
Multi Center Reconnect Interval

42

This item is valid only when the Data Center Number is greater than 1.
When one of the configured data center lost connection, IP MODEM will try to
reconnect after the configured reconnect interval
AT Command:
AT+MCONTIME=xxx
xxx: reconnect time interval (unit is second)
10.3.6 Functions
Clear Output

Clear the output information


Version Display

Show the software and hardware version


Signal

Value

Display current wireless signal value


Factory setting

Restore to factory settings


Show Config

Show current IP MODEM settings


Show Baud rate

Display the communication baud rate


Auto Detect

Simple way to determine whether IP MODEM work fine


Save Output

Save the output info to a file


Save Config

43

Save the current settings to a file, you can restore it from this file later
Restore Config

Restore settings from a previous saved configure file


10.3.7 Work state switch

This tool can work in two states, Config and Communication


Config:
This state is used to configure parameters of IP MODEM.
Communication:
This state is used as a common serial communication tool
Reboot Device, Enter Communication State:
This function button is used to reboot IP MODEM and make the software switch to
Communication state.

44

10.4 Data transfer test environment testing


10.4.1 Test environment net structure

Server: simulate real data center, run Server Demo on the Server, suppose Servers
IP address is 222.76.128.204, and DEMO monitor terminal 5001.
PC: simulate serial port for collect data, run testing serial port tool.
The PC send data to Server follow process as below:
PC serial port data IP MODEM serial port IP MODEM TCP/IP protocol to
encapsulation for TCP/IP send to wireless network wireless network send data
to INTERNET INTERNET send data to Server.
10.4.2 Testing step
10.4.2.1 Run DEMO in the Server, select at the tools, the data service center is
monitoring terminal 5001 (define other terminal as user needed)
10.4.2.2 Configure IP MODEM parameter
Data service center IP is 222.76.128.204port is 5001, configure as below:
10.4.2.3 Close IP MODEM configure tool, run serial port testing program.
10.4.2.4 Confirm SIM card is connected well, and restart IP MODEM.
10.4.2.5 Serial port tool remind IP MODEM connect with data center well.
10.4.2.6 Via serial port tool send data to Server, data center DEMO is display
received data, it prove serial port tool send data to data center is correct.
10.4.2.7 Data center send data to serial port tool.
Above tests have shown that, data center DEMO and serial port tool have able to
bidirectional data transmission.

45

10.5 Appendix
The following steps describe how to make IP MODEM enter configure state with the
Windows XP Hyper Terminal.
1. Press Start Programs Accessories Communications Hyper
Terminal

2. Input connection name, choose OK


3. Choose the correct COM port which connect to IP MODEM, choose OK

4. Configure the serial port parameters as following, choose OK


Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None

46

5. Complete Hyper Terminal operation, it runs as following

6. Re-power IP MODEM, put mouse focus on the Hyper Terminal and press s key
continuously until IP MODEM enter configure state as following

47

7. IP MODEM has entered configure state, you can configure the parameters through
AT command.

11 System software
11.1 Introduction
Automatic

environmental

air

quality

monitoring

system

is

automatic

measuring-control system centering on automatic monitoring instruments. The


system is the latest technical products that bases on the technology of dry instruments,
makes use of the principle of constant potential electrolytic sensor, and combines
internationally mature electronic technology and network communication technology.
The system conforms to state requirements for technical indexes of automatic urban
environmental air monitoring system. It has high degree of domestic as well as strong
practicality and ideal price-performance ratio, may substitute the same kind of
imported products, and is the ideal apparatus for automatic monitoring of urban
environmental air in cities. Automatic environmental air monitoring system consists of
one central station and several substations (number of substations based on local
circumstances). Substation system transmits data to central station system through
INTERNET. Substation software is used for data acquisition and data storage. Central

48

station software is designed to coordinate the operation of the whole monitoring


system, complete monitoring instruments data collection, data processing, remote
communication control, and air quality monitoring report.

Characteristics
1. Remote data communication via GPRS wireless
2. Automatic data transmission
3. Automatic generation of hour average data and daily average data
4. The data can be easily queried and exported to EXCEL files and text files.

11.2 Software Installation


11.2.1 Installation of SQL Server 2005 Express

49

Figure SQL2005 Installation program

11.2.1.1 Put a check in the I accept the licensing terms and conditions, then click
Next, start to install.

Figure 8 SQL Server installation support program

11.2.1.2 Click Install, start to install.

50

Figure 9 SQL2005 Installation system check

11.2.1.3 Click Install, start to install.


11.2.1.4 Choose the configuration; click Next, start to install.

Figure 10SQL Instance name choose

51

11.2.1.5 Select Default instance, click Next, start to SQL Server account choose.

Figure 11 SQL2005 Service Account choose

11.2.1.6 Select Use the built-in System account and choose Local system.
Under Start services at the end of setup, ensure that the SQL Server check box is
checked.

Figure 12SQL 2005 Authentication Mode

52

11.2.1.7 Select Mixed Mode, and put password :sa, click Next, start to setting.

Figure 13 SQL2005 Collection settings

11.2.1.8 Select Default, click Next, start to error and usage report settings.

Figure 14 SQL2005 Error and Usage Report Settings

53

11.2.1.9 Select Default, Click Next, start to install SQL Server.

Figure 15SQL 2005 Ready to Install

11.2.1.10 Click Install to start to setup.

Figure 16 SQL2005 Setup Progress

54

11.2.1.11 Setup progress

Figure 17 SQL2005 Setup finished

11.2.1.12 SQL Server 2005 Setup finished, click Next button.

Figure 18Setup finished

55

11.2.1.13 SQL Server 2005 Setup finishedClick Finish button.


11.2.2 Monitoring Software Installation
11.2.2.1 To begin the installation process, double-click setup.exe.

Figure 19 Installation wizard

11.2.2.2 Select the install path for installation. Usually use the default path.

Figure 20 Installation Directory interface

11.2.2.3 Finished the installation, click Close. Double-click the icon on desktop or
click the icon from start menu to launch the software.

56

Figure 21 Installation Finished

11.3 Software Operating Instructions


11.3.1 Software Setting

Figure 22System Setting

11.3.1.1 Select the data communication mode:


1. Serial port
2. DTU equipment (wireless communication module).
This system mainly uses GPRS remote wireless communication.

57

11.3.1.2 Network port number: User can set the port number which must be
consistent with the DTU port, in order to ensure the normal communication.
11.3.1.3 Set the serial port to receive data (defaultCOM1).

Figure 23 Software Main Interfaces

11.3.2 Data Inquiry and Export

Figure 24 Data Inquiry interface

The interface above shows the Inquiry/Export interface. Select a date and click View
to query data. The query result could be saved as an Excel file or text file. User can

58

save query result into Excel file by clicking button Save As Excel. For further analysis,
the query result can be saved as a text file by clicking button Save As Text.

Figure 25Data Export interface

11.3.3 Data Report Print


Print the enquire result based on the enquire time.

Figure 26Data Report Print interface

59

11.3.4 System Log


The system log records software startup and some important software running
information. When software problem occurs, system log could be used as reference
information to solve software problems by user.

Figure 27 Data Print Interface

11.3.5 Data Inquiry and Export, save

Software would open the data which export from device, and translate to usually data
mode, at here be Excel mode.

11.4 Frequently Asked Questions


11.4.1 The software is installed correctly, System prompts following information

60

The above prompt indicates the software authentication U disk is not inserted into the
current computer.
SolutionInsert the software authentication U disk
11.4.2 The software is opened properlybut there is no substation connected to the
software.
SolutionCheck below settings:
1 The network works properly.
2 The network port is opened.
3 The DTU settings are correct.
4 The GSM card cost is enough.

61