Anda di halaman 1dari 42

ALARMS & INDICATION

HAUL AMRIMDSI T& Y


I N D I C AT I O N

Kele Offers Custom Assemblies and FREE Display Calibrations.

RAD-1 | p. 66

51XBR Series | p. 69

AIS | p. 65

MNST/MST1 | p. 92
Series

Pilla

Electrical
Products, Inc.

869/869STR | p. 67

ST120 Series | p. 90

Pilla Electrical
Products, Inc.

ALARMS & INDICATION


Products manufactured
in the United States

ALARMS &
I N D I C AT I O N

Products that are


new to the catalog

MODEL/SERIES PAGE
Alarm and Indication Stations
AIS Kele Alarm Indication Station. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
RAD-1 Kele Remote Alarm Indication Station . . . . . . . . . . . . . . . . . . . . . . . . 66
Emergency Operator Stations
E-Stop ESB Series Operator Stations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E-Stop ESM Series Emergency Operator Stations. . . . . . . . . . . . . . . . . . . .
E-Stop ESP Series Emergency Operator Stations . . . . . . . . . . . . . . . . . . . .
ST120 Series Operator Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WPS Series Plate Mounted Operator Stations. . . . . . . . . . . . . . . . . . . . . . . .
MNST and MST1 Series Power Control Stations . . . . . . . . . . . . . . . . . . . . .

200 Class | p. 80
ClearView

ESM Series | p. 86

84
86
88
90
91
92

Loop Powered Indicators


VPI Series 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
SGD-24, -28 PanelPilot Smart Graphical Display. . . . . . . . . . . . . . . . . . . . . . 94
BDR Series Kele Big Display Readout, 3-1/2 Digit LED, Red / Blue /
Green . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
LPI-1C 3-1/2 Digit LCD Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
LPI-1C-A, LPI-1C-G, LPI-1C-R 3-1/2 Digit LCD Amber / Green / Red
Panel Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
LPI-3C, LPI-3C-A, LPI-3C-G or LPI-3C-R 4-1/2 Digit Black / Amber /
Green / Red Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
LPI-4 Kele 3-1/2 Digit Large Black / Red / Green / Amber Panel Display. . . 100
LPI-5 Kele 3-1/2 Digit Small Black / Red Panel Display . . . . . . . . . . . . . . . . 101
Multi-Status Indicators
105XBRi Series XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . . 76
125XBRi Series XTRA-BRITE LED Multi-Status Indicator . . . . . . . . . . . . . . 78
Run Time Accumulator
ALD-1 Pulse or Run-time Accumulator Display . . . . . . . . . . . . . . . . . . . . . . 102

ESP Series | p. 88

Strobes and Horns


125STR, 89STR, 869STR, 869, 868STR, 868 Strobes & Horns . . . . . . . . . .
SC-Series Alarm Horn. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STB, STB-H Wall-Mounted Strobe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51XBR Series XTRA-BRITE LED Beacon with Horn. . . . . . . . . . . . . . . . . . .
57 Series Polaris Class LED Beacon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
94 Series Polaris Class LED Beacon. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
107XBR Series XTRA-BRITE LED Hazardous Location Beacon . . . . . . . . .
105XBRM Series XTRA-BRITE LED Adverse Location Visual Signals. . . . .
125XBR Series XTRA-BRITE LED Beacons. . . . . . . . . . . . . . . . . . . . . . . . .

67
68
68
69
70
71
72
74
75

Tower Lights
200 Class ClearView LED Stacklight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
TWS Series 75 mm Tower Lights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

kele.com

NEW!

ALARMS & INDICATION


KELE ALARM INDICATION STATION

DESCRIPTION

The Model AIS Alarm Indication Station features an


indication light, alarm horn and an alarm horn silence switch.

SEQUENCE OF OPERATION

Upon an alarm contact closure, the LED indicator will light, and the
horn will sound. The horn can be silenced through the alarm silence
switch, while the visual indication will continue to be lighted until the
alarm condition has been corrected. A power interruption or open
alarm contact will reset the AIS.

FEATURES

Long lasting, red LED indication


Distinct continuous audible tone
Horn silence switch
Compact and rugged design
Available in 24 VDC, 24 VAC, or 120 VAC
Bright yellow panel face

ALARMS & INDICATION

APPLICATION








Refrigerant leak alarm indication


Water level alarm indication
Pressure alarm indication
High/Low temperature limits
Gas leak indication
Humidity limit alarm indication
Vibration limit
Voltage/Current level limit
Any contact closure alarm application

WIRING
Four-wire connection

SPECIFICATIONS
Supply Voltage
Contact Rating
AIS-24D
AIS-24A
AIS-120A
Alarm Horn
Dimensions
Mounting
Enclosure
Approvals
Weight
Warranty

Power supply
24 VAC/VDC or 120 VAC

Remote alarm device


Alarm initiated by
contact closure

24 VAC/ VDC, 120 VAC,


100 mA max

24 VDC, 50 mA min
24 VAC, 90 mA min
120 VAC, 70 mA min
80 db
7.09"H x 4.33"W x 3.54"D
(18.0 x 11.0 x 9.0 cm)
Four screws through back
Polystyrene, impact resistant,
knock-outs
RoHS
1.1 lb (0.5 kg)
1 year

N.C.

AIS internal
terminal strip

A power interrupt or open alarm contact


will reset the AIS to normal.
N.C.=no connection

Two-wire connection

1
2

N.C.

N.C.

Power supply
24 VAC/VDC or 120 VAC

4
5

N.C.

AIS internal
terminal strip

A power interrupt or open alarm


contact will reset the AIS to normal.
Remote alarm device
Alarm initiated by
N.C.=no connection
contact closure

ORDERING INFORMATION
MODEL DESCRIPTION
AIS
Alarm indication station
12VD 12 VDC powered
24D
24 VDC powered
24A
24 VAC powered
120A 120 VAC powered
AIS

March 2014

24A

Example: AIS-24A 24 VAC powered alarm


indication station

WE MAKE IT EASY.

kele.com

888-397-5353 USA

65

NEW!

ALARMS & INDICATION

KELE REMOTE ALARM INDICATION STATION


RAD-1

DESCRIPTION

ALARMS & INDICATION

The RAD-1 is a wall mounted remote alarm indication station


mounted on a stainless steel plate. Any contact closure alarm
initiating device that can switch 24 VAC or DC can be used
with the RAD-1.

SEQUENCE OF OPERATION
When 24 VAC or VDC is applied to the RAD-1 through an
alarm-initiating device, the red alarm LED will light, the horn
will sound, and the alarm status relay will energize. If an initial
alarm delay has been set, when 24 VAC or VDC is applied, the
red alarm LED will blink until the delay period has expired. Then
it will light continuously, the horn will sound continuously, and
the relay will energize. If power is interrupted, the RAD-1 will
reset to normal state.
During an alarm (24V applied to the RAD-1), the horn may be
silenced by momentarily pressing the silence switch. The alarm
LED will remain lighted, and the alarm status relay will remain
energized when the horn is silenced until the alarm condition is
cleared (24V removed). If an alarm repeat after silence time has
been set, the horn will re-sound at the end of the repeat time.
If the relay-follows-horn jumper is installed, the alarm status
relay will de-energize when the horn is silenced and re-energize
when the horn sounds at the end of the repeat-after-silence
time.
If a pulsed (instead of continuous tone) horn is desired, the
horn-pulsed jumper may be installed. If both the horn pulsed
jumper and the relay-follow-horn jumper are installed, the alarm
status relay will energize and de-energize with the pulsed horn.

FEATURES






Red alarm LED


Alarm horn, continuous tone or pulsed
Alarm horn silence switch
Adjustable alarm delay time
Adjustable alarm repeat time
Alarm status SPDT relay
Relay operates with the alarm horn option

WIRING
No jumper

HORN PULSED
REPEAT TIME x10
DLY TIME x10
Alarm Repeat after
Silence Time*
SW6SW8 OFF = No delay
SW6 ON = 1 minute
SW7 ON = 2 minutes
SW8 ON = 4 minutes
Initial Alarm Delay Time*
SW1SW5 OFF = No delay
SW1 ON = 1 second
SW2 ON = 2 seconds
SW3 ON = 4 seconds
SW4 ON = 8 seconds
SW5 ON = 16 seconds

ON

OFF

Repeat
time in
2 minutes
1 (add)

16

8
7

Alarm initiating
device

24 +
VAC/
VDC

NO

Repeat
time in
seconds Relay COM
(add)
NC

Relay
follows
horn

Jumper installed

Continuous horn Pulsed horn


Alarm repeat
Alarm repeat
after silence
after silence
time x1
time x10
Inital alarm
Initial alarm
delay time x10
delay time x1

NO
COM

Alarm
relay

NC

RAD-1

* Times are additive; for example, with SW3 and SW5 both ON, 4 sec + 16 sec = 20 sec delay
(or 200 sec if DLY TIME x10 jumper is installed)

SPECIFICATIONS
Supply Voltage
Alarm Delay Time
Alarm Horn
Alarm Repeat Time
Alarm Status Relay

24 VAC @ 100 mA or 24 VDC @ 34


mA
None, or 1 to 31 seconds in onesecond increments, or 10 to 310
seconds in 10-second increments
Continuous or pulsed tone, 70 db
min
None, or 1 to 7 in one-minute
increments, or 10 to 70 minutes in
10-minute increments
SPDT, 0.5A @ 24 VAC, 1.0A @ 30
VDC

Connections
Dimensions
Mounting
Approvals
Weight
Warranty

Screw terminals, 22 - 14 AWG wires


4.5"H x 2.75"W x 1.0"D
(11.4 x 7.0 x 2.5 cm)
Brushed stainless steel plate mounts
to standard single junction box, two
screws provided
RoHS
0.19 lb (0.07 Kg)
18 months

ORDERING INFORMATION
MODEL
RAD-1

66

888-397-5353 USA

kele.com

DESCRIPTION
Remote alarm indication station

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


STROBES & HORNS
125STR, 89STR, 869STR, 869, 868STR, 868

DESCRIPTION

Signal strobes and horns available in wall-mount and panelmount configurations with a variety of colors and voltages.
Model 125STR is a 120 VAC panel-mount strobe in NEMA
4X enclosure. Model 89STR mounts on a single-gang box
and is a single, indoor, flush-mount strobe. Model 869STR is
an indoor, flush-mount horn and strobe combination. Model
869 is an indoor, flush-mount horn only. Model 868 STR is an
outdoor, surface-mount horn and strobe combination. Model
868 is an outdoor, surface-mount horn.

2
869

869STR

Indoor and outdoor applications


Amber, blue, clear, green, and red colors
24 VAC, 24 VDC, and 120 VAC
Surface and panel mount

ALARMS & INDICATION

FEATURES

125STRH

868STR

SPECIFICATIONS
Supply Voltage
N5 (89, 869, 868)
AQ (89, 869, 868)
120A (125STRH)
Current Rating
125STRH
Horn/Strobe


Average Candela
Amber
Blue
Clear
Green
Red
Color
Horn Loudness
Peak Candela
Strobe Tube Life

120 VAC
24 VDC, 24 VAC
120 VAC -20% to +10% of nominal
voltage
120 mA
24 VDC, 22 mA/390 mA
24 VAC, 72 mA/390 mA
120 VAC, 24 mA/87 mA
90 cd
20 cd
150 cd
70 cd
21 cd
Amber, blue, clear, green, red
90 dba @ 10'
300,000 cd
3,000 hrs, 1,000 hrs

ORDERING INFORMATION
MODEL
125STRH
89STR
869STR
868STR
869
868

868STR

March 2014

DESCRIPTION
Panel-mount strobe
Indoor flush-mount strobe
Indoor flush-mount electronic horn/strobe
Outdoor surface-mount electronic horn/strobe
Indoor flush- or panel-mount electronic horn
Outdoor surface-mount electronic horn
COLOR
A
Amber
B
Blue
C
Clear
G
Green
R
Red
SUPPLY VOLTAGE
AQ 24 VAC/VDC (89, 869, 868)
N5
120 VAC (89, 869, 868)
120A 120 VAC (125STRH only)
B

AQ

Operating Humidity
868, 868 STR
869, 89 STR, 869 STR
Operating Temperature
868, 868 STR
869, 89 STR, 869 STR
Dimensions
89 STR
869 STR, 868 STR,
869, 868
Enclosure Rating
125 STRH
Mounting
868
869
Approvals
Warranty

95% RH @ 86F (30C)


85% RH @ 86F (30C)
-31 to 150F (-35 to 66C)
32 to 120F (0 to 49C)
5"H x 3-3/8"W (12.7 x 8.6 cm)
5-1/2"H x 5-1/2"W (14 x 14 cm),
NEMA 4X
Weatherproof surface box supplied
no NEMA rating
3" sq x 1-1/2" electrical box with 1-1/2"
extension ring (need 3" depth)
UL 1638 listed, cUL
2 years

WIRING

868 STR/869 STR


Horn/Strobe

Strobe

Horn

+
+

Example: 868STR-B-AQ Outdoor surfacemount electronic horn with blue


strobe and 24 VAC/VDC

WE MAKE IT EASY.

kele.com

888-397-5353 USA

67

NEW!

ALARMS & INDICATION

ALARM HORN
SC-SERIES

DESCRIPTION

The SC Series Alarm Horns provide an audible tone when


an electric signal is applied. They can be used in applications
when an audible alarm is needed to indicate that immediate
attention is required.

ALARMS & INDICATION

SPECIFICATIONS

Supply Voltage
SC110
SC628
SC628A, AN
Current Rating
SC100
SC628
SC628AN
SC628A
Horn Loudness
Tone
Panel Cutout
Weight
Approvals
Warranty

30-120 VAC/VDC
6-28 VDC
6-28 VAC/VDC

6-21 mA
3-18 mA
4-30 mA
6-23 mA
Medium, 68-80 dB
(AN model Loud, 80-95 dB)
Continuous
Panel, cutout 1.13" (2.87 cm)
0.1 lb (0.05 Kg)
UL recognized component File# S1290
1 year

WIRING

SC Horn

ORDERING INFORMATION
MODEL
SC110
SC628
SC628A
SC628AN

DESCRIPTION
Alarm horn, 120 VAC
Alarm horn, 24 VDC
Alarm horn, 24 VAC/VDC
Alarm horn, 24 VAC/VDC

Horn

DESCRIPTION

WALL-MOUNTED STROBE
STB, STB-H

The Model STB and STB-H wall-mounted strobes provide a


bright, eye-catching warning light for any alarm application.
The STB-H features a distinct audible signal.

FEATURES
Wall mounted with 4" square or double-gang box
Integral alarm horn (91 db)
24 VDC powered
15/75 candela strobe intensity
Meets requirements of ADA4.28.3
UL listed
Xenon strobe for constant flash rate
Strobe and horn powered separately if desired
Jumper-selectable, continuous or temporal tone

WIRING
Signal
S+ S+

SPECIFICATIONS

68

888-397-5353 USA

kele.com

80 mA at 24 VDC
136 mA at 24 VAC
1 Hz
104 dB max
15 (off-center) candela 75
(on-center) candela
Operating Temperature 32 to 120F (0 to 49C)
Dimensions
4.5"H x 4.56"W x 2.25"D

(11.43 x 11.58 x 5.72 cm)
Weight
STB
1.0 lb (0.45 Kg)
STBH
1.1 lb (0.5 Kg)
Approvals
UL Listed File S3406
Warranty
3 years

20-31 VDC (24 VDC nominal)

Supply Voltage
Current Rating
STB
STB-H
Strobe Frequency
Horn Loudness
Strobe Intensity

H- H+

S-

Note: Switch 1, 2 off

ORDERING INFORMATION
MODEL
STB
STB-H

DESCRIPTION
Wall-mounted strobe
Wall-mounted strobe with horn

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


XTRA-BRITE LED BEACON WITH HORN
51XBR SERIES

DESCRIPTION

The 51XBR Series XTRA-BRITE LED beacons are


combination visual and audible signaling devices, designed
for indoor or outdoor applications. The integrated horn is
synchronized with the flashing LED. The unit features a cast
metal base that can be used as a junction box. The double
fresnel lens is made of shatter-resistant polycarbonate, and is
designed to magnify the superbright LED.

FEATURES

LED light source with integrated horn


Shatter-resistant double fresnel polycarbonate lens
Five lens color options
Immune to shock and vibration
Cast metal base
Suitable for indoor and outdoor applications

ALARMS & INDICATION

SPECIFICATIONS

51XBR

WIRING

+ NEUTRAL

GND

24 VDC
POWER

WHITE

BLACK

BLACK

120 VAC
WIRING
GREEN

24 VDC
WIRING

RED

Supply Voltage

51XBRFx120A
120 VAC, 50/60 Hz,
51XBRFx24D
24 VDC
Current
51XBRFx120A
175 mA
51XBRFx24D
275 mA
Max. Off State Leakeage
Current
10 mA
Surge (inrush / duration)
51XBRFx120A
50 A / 260 s
51XBRFx24D
10 A / 120 s
Colors
Amber, blue, green,red, white
Flash Rate
65 FPM
Projected LED Life
148,000 hours
Horn Loudness
85 dB @10'
Strobe Tube Life
148,000 hours
Operating Temperature -31F to 150F (-35C to 66C)
Dimensions
7.38"H x 6"W (18.7cm x 15.2cm)
Mounting
Direct surface mount
Mounted on 1/2 in. NPT conduit
Mounted on a 4 in. octagon box
Approvals
cULus Listed, uL
Weight
2.14lbs (0.97 kg)
Warranty
18 months

120 VAC
POWER
Wire nuts not included.

DIMENSIONS

in
(cm)

ORDERING INFORMATION

7 3/8"
(187mm)

MODEL
51XBRF

DESCRIPTION
Combination flashing LEDs with horns
COLOR
A
Amber
B
Blue
G
Green
R
Red
W
White
SUPPLY VOLTAGE
24D 24 VDC
120A 120 VAC @ 50/60 Hz

57PLEDM

3 1/2"
(89mm)

6"
(152mm)

3/4"
(19.05mm)
1/2"
(12.7mm)
conduit hole

24D

March 2014

WE MAKE IT EASY.

Example: 51XBRFG24D Combination


flashing LEDs with horns and
24V DC

kele.com

888-397-5353 USA

69

ALARMS & INDICATION


POLARIS CLASS LED BEACON
57 SERIES
DESCRIPTION

Edwards Polaris Class 57PLEDM LED beacons are NEMA


Type 4X and IP66 rated visual signals designed for indoor and
outdoor applications.The Polaris Class is designed for industrial
or commercial applications that require the longevity of an LED
combined with the brightness of a xenon strobe. These units are
very effective in high noise areas where ear protection is worn
or audible signals may not be heard.

ALARMS & INDICATION

FEATURES




Six lens colors


Seven flash patterns (includes steady-on)
Hidden in Plain Sight (HIPS) switch
High level of immunity to shock and vibration
Black or gray base option

57PLEDMB

SPECIFICATIONS

DIMENSIONS

Supply Voltage
57PLEDMx24ADx
12 VDC, 0.7A, 24 VAC/VDC, 0.55A
57PLEDMx120Ax
120 VAC, 50/60Hz, 0.25A
Leakage Current
Off State Leakage 5 mA
Surge Current
57PLEDMx24ADx
8.5A/2ms
57PLEDMx120Ax
4.5A/1ms
Color
Amber, blue, green, magenta, red, clear
Projected LED Life 148,000 hours
Flash Mode
7 selectable patterns with HIPS switch
Operating Temperature -31 to 150.8F (-35 to 66C)
Dimensions
8" x 6.5" (203 x 165 mm)
Enclosure Rating
NEMA 4X
Mounting:

On 3/4" (19mm) NPT threaded conduit
Approvals
UL 1638 and cUL Listed (E11459)
Weight
3.4 lbs (1.54 kg)
Warranty

18 months

8"
(203mm)

6.5"
(165mm)

ORDERING INFORMATION

WIRING

24 VAC
POWER

GND

MODEL
57PLEDM

DESCRIPTION
LED beacon
COLOR
A
Amber
B
Blue
G
Green
M
Magenta
R
Red
W
White
SUPPLY VOLTAGE
24AD 12-24 VDC, 24 VAC @ 50/60 Hz
120A 120 VAC @ 50/60 Hz
BASE COLOR
(Blank)
Gray
B
Black

57PLEDM

WHITE

BLACK

GREEN

+ NEUTRAL

GND

24 VDC
POWER

120 VAC
WIRING

RED

BLACK

24 VAC
WIRING
GREEN

RED

BLACK

24 VDC
WIRING

+ NEUTRAL
120 VAC
POWER

Wire nuts not included.

ACCESSORIES


CBR
Corner Mount Bracket

70

888-397-5353 USA

57PLEDMA

57PLEDMR

WBR
Wall Mount Bracket

kele.com

CBR
WBR

24AD

Example: 57PLEDG24AD LED beacon


with green lens, gray base, and
12-24 VDC, 24 VAC @ 50/60 Hz

ACCESSORIES
Corner Mount Bracket
Wall Mount Bracket

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

PAGE
70-71
70-71

March
2014
March
2014

NEW!

ALARMS & INDICATION


POLARIS CLASS LED BEACON
94 SERIES

DESCRIPTION

2
94PLEDMA

DIMENSIONS

7.75"
(200mm)

HIPS
Programming
Switch
8.25"
(210mm)

WIRING

GND

24 VDC
POWER

WHITE

+ NEUTRAL
120 VAC
POWER

Wire nuts not included.

12 VDC, 0.7A; 24 VAC/DC, 0.55A


120 VAC, 50/60Hz, 0.25A
Off State Leakage 5mA

8.5 A / 2 ms
4.5 A / 1 ms
Amber, blue, green, magenta, red,
white/clear
Projected LED Life
148,000 hours
Flash Mode
7 Selectable Patterns with HIPS
Switch
Operating Temperature -31 to 150.8F (-35 to 66C)
Dimensions
94PLEDMx Models 8.25" x 7.75" (210 x 200 mm)
Enclosure Rating
NEMA 4X and IP66 Rated
Mounting
On 3/4 inch NPT conduit
(indoor or outdoor)
Approvals
UL 1638 and cUL Listed (E11459)
Weight
6.10 lbs (2.77 kg)
Warranty
18 months
March 2014

GND

24 VAC
POWER

SPECIFICATIONS
Supply Voltage
94PLEDMx24ADx
94PLEDMx120Ax
Leakage Current
Surge Current
94PLEDMx24ADx
94PLEDMx120Ax
Color

+ NEUTRAL

120 VAC
WIRING
GREEN

BLACK

BLACK

RED

24 VAC
WIRING
GREEN

24 VDC
WIRING

RED

12-24 VDC, 24 VAC, 120 VAC


Six lens colors
Seven flash patterns (includes steady-on)
Hidden in Plain Sight (HIPS) switch
3/ " (19mm) NPT threaded conduit
4
High level of immunity to shock and vibration
Black or gray base option

BLACK

FEATURES






94PLEDMG

94PLEDMR

ALARMS & INDICATION

Edwards Polaris Class 94PLEDM LED beacons are NEMA


Type 4X and IP66 rated visual signals designed for indoor
and outdoor applications. The units are available in Edwards
94 Series housing in 12-24 VDC, 24 VAC, 120 VAC and
are field configurable with up to seven flashing patterns,
including steady-on, utilizing a Hidden In Plain Sight (HIPS)
switch. The inner, double fresnel lens is made of a high grade
polycarbonate and is designed to magnify the ultra-bright
LEDs inside. A clear, outer, impact-resistant polycarbonate
dome offers additional protection against accidental impacts
with machinery or falling objects. It also acts as a protective
and simple to clean dust and residue cover. The Polaris
Class beacons are designed to be mounted on 3/4 inch
NPT conduit (indoor or outdoor). For outdoor installation and
to maintain the NEMA and IP ratings, the beacon must be
mounted with the dome facing directly up. When installing
the beacon indoors in dry environments, it can be mounted
in any position. The 94 Series housing has a cast base that
can function as a junction box. The Polaris Class is designed
for any industrial or commercial applications that require the
longevity of an LED and the brightness of a xenon strobe.
These units are very effective in high noise areas where ear
protection is worn or audible signals may not be heard.

ORDERING INFORMATION
MODEL
94PLEDM

DESCRIPTION
LED beacon
COLOR
A
Amber
B
Blue
G
Green
M
Magenta
R
Red
W
White
SUPPLY VOLTAGE
24AD 12-24 VDC, 24 VAC @ 50/60 Hz
120A 120 VAC @ 50/60 Hz
BASE COLOR
(Blank)
Gray
B
Black

94PLEDM


CBR
WBR

WE MAKE IT EASY.

24AD

Example: 94PLEDG24AD LED beacon


with green lens, black base, and
12-24 VDC, 24 VAC @ 50/60 Hz

ACCESSORIES
Corner Mount Bracket
Wall Mount Bracket

kele.com

888-397-5353 USA

PAGE
70-71
70-71

71

ALARMS & INDICATION


XTRA-BRITE LED HAZARDOUS LOCATION BEACON
107XBR SERIES
DESCRIPTION

ALARMS & INDICATION

The 107XBR hazardous location XTRA-BRITE LED visual


signals are NEMA Type 3R and Type 4 heavy-duty visual
signals designed for indoor or outdoor applications. The units
are available in 24 VDC or 120 VAC and are field configurable
for steady-on or flashing (65 fpm). The inner, double fresnel
lens is made of a high grade polycarbonate and is designed
to magnify the super-bright LEDs inside. A clear, outer,
impact-resistant glass globe also covers the lens and an
optional dome guard fits over the glass dome to protect it
against accidental impacts with machinery or falling objects.
The 107XBR has three different mounting configurations
including the pendant mount, bracket mount and ceiling
mount and can be mounted on 3/4" NPT threaded conduit.
The 107XBR is designed for applications such as petroleum
refineries, utility gas plants, dry cleaning plants, fuel servicing
areas and other similar applications.

107XBRCMG

107XBRPMR

107XBRBMA

FEATURES






Available in 24VDC or 120VAC


Five lens colors
Steady-on or flashing in every unit
3/4" NPT threaded conduit
High level of immunity to shock and vibration
Three mounting options: pendant, bracket or ceiling
UL Listed for Class I, Division 2, Groups A, B, C, D; Class II,
Division 1, Groups E, F, G; Class II, Division 2, Groups F &
G and Class III, Division 1 locations
UL and cUL Listed for Marine environments (120VAC only)

WIRING
Connect leads to
Power Source

Wire nuts (not supplied)

Yellow,
Not Connected
(wire nut supplied)

DC units; Red positive (+)


AC units; Black Hot
DC units; Black negative (-)
AC units; White neutral

SPECIFICATIONS
Supply Voltage
107XBRxMx24D
107XBRxMx120A
Current
107XBRxMx24D
107XBRxMx120A
Color
Flash Mode

24 VDC
120 VAC, 60Hz

220 mA
115 mA
Amber,blue,green,red,clear
Steady on or flashing
(65 FPM, field configurable)
Project LED Life
148,000 hours
Operating Temperature See Table on next page
Dimensions
7" X 10.13" (178 x 260 mm)
Enclosure Rating
NEMA 3R and NEMA 4
Mounting
Bracket mount, pendant mount, ceiling mount
Approvals
UL & cUL Listed, UL Listed for Marine Use
Weight
107XBRBMx
10.87 lb (4.93 kg)
107XBRCMx
9.87 lb (4.47 kg)
107XBRPMx
8.97 lb (4.06 kg)
Warranty
18 months

Connect leads to
Power Source
Yellow

(Yellow wire connected


for Optional flash pattern)

DC units: Connect
to Positive (+)
AC units: Connect to Hot

Wire nuts (not supplied)


DC units; Red positive (+)
AC units; Black Hot
DC units; Black negative (-)
AC units; White neutral

Flash Rate
65 fpm

* Class II and Class III only apply to the pendant mount versions with clear globes.
** Marine Rating applies to UL listing only.

72

888-397-5353 USA

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION

XTRA-BRITE LED HAZARDOUS LOCATION BEACON


107XBR SERIES

OPERATING TEMPERATURE CODES


Class II, Div. 2,
Groups F, G; Class
III, Div. 2

Class I, Div. 2
Groups A, B, C, D

Class II, Div. 1,


Groups E, F, G;
Class III, Div. 1

40C

135C (T4)

85C (T6)

55C

135C (T4)

85C (T6)

65C

135C (T4)

85C (T6)

Note: Class II and Class III only apply to the pendant mount versions
with clear globes.

DIMENSIONS
10 1/2"
(267mm)

9 7/8"
(251mm)

4"
(102mm)

9 3/4"
(248mm)

11 3/8"
(289mm)

10 1/4"
(260mm)

ALARMS & INDICATION

Ambient
temperature

10 1/8"
(260mm)

10 7/8"
(276mm)

7"
(178mm)

7"
(172mm)

Pendant Mounting

Bracket Mounting

Ceiling Mounting

ORDERING INFORMATION
MODEL
107XBR

DESCRIPTION
Hazardous Location LED Beacon
MOUNTING
PM Pendant
BM Bracket
CM Ceiling
COLOR
A
Amber
B
Blue
G
Green
R
Red
W
White
SUPPLY VOLTAGE
24D 24V DC
120A 120V AC @ 60 Hz

107XBR

BM

120A

Example: 107XBRBMW120A Hazardous Location


LED Beacon with bracket mounting, white
LED, and 120V AC @ 60 Hz

ACCESSORIES
EDVPGU1
Optional Dome Gaurd

March 2014

WE MAKE IT EASY.

kele.com

888-397-5353 USA

73

ALARMS & INDICATION


XTRA-BRITE LED ADVERSE LOCATION VISUAL SIGNALS
105XBRM SERIES
DESCRIPTION

ALARMS & INDICATION

The 105XBRM Series LED visual signals are heavy duty,


reliable, UL, cUL beacons. The 105XBRM Series features a
UL listed Type 4X enclosure and is UL Listed for Marine Use.
The 105XBRM Series has three different configurations for
mounting that include the 105BX junction box, the 105BM
mounting bracket, and the 105PM pipe mount attachment.
The unit can be mounted on 3/4 NPT using the 105PM pipe
attachment. It can also be surface mounted using the 105BX
junction box, or wall mounted using the 105BX junction box
with the 105BM mounting bracket. They can only be used with
metallic wiring systems when installed at the end of the run.

FEATURES

105XBRMB

Available in 24V DC or 120V AC


Three mounting bases: 3/4" pipe mount attachment,
outlet box attachment, or wall mounting bracket
65 fpm mode field-selectable via dipswitch
Immune to shock and vibration

WIRING

SPECIFICATIONS

Supply Voltage
105XBRMx24D
105XBRMx120A
Current Rating
105XBRMx24D
105XBRMx120A
Color
Flash Mode

105-L Series
Lens

24 VDC
120 VAC 50/60Hz

OFF

OFF

ON
ON
STEADY

105XBR Base

0.215
0.108A
Amber, blue, green, red, white
Steady on or 65 FPM (dipswitch
settings)
Projected LED Life
148,000 hours
Operating Temperature -31 to 212F (-35 to 100C)
Dimensions
4.75" X 3.75" (121 x 95mm)
Enclosure Rating
NEMA 4X
Mounting
" pipe mount attachment, outlet
box attachment, or wall mounting
bracket
Approvals
UL & cUL Listed, UL Listed for
Marine Use
Weight:
1.4 lbs (0.63 kg)
Warranty:
18 months

18 Wire Leads
DC units; Red Positive (+),
AC units; Black Hot

OFF

OFF

DC units; Black Negative (-),


AC units; White Neutral
Wire nuts
(not supplied)

ON
ON
65 FPM

(Dipswitches located
inside the unit)

Power Source
Wires

HAZARDOUS LOCATION RATINGS

MODEL

Class

Division

Group

Operating Temperature

I
II
III

2
2

A, B, C, D
F, G

T4A (120C, 248F)


T4A (120C, 248F)
T4A (120C, 248F)

105XBRMx24D
105XBRMx120A

ORDERING INFORMATION
MODEL
DESCRIPTION
105XBRM XTRA-BRITE LED Adverse Locations Visual Signals
COLOR
A Amber
B Blue
G Green
R Red
W White
SUPPLY VOLTAGE
24D 24V DC
120A 120V AC
105XBRM

74

N5

Example: 105SLEDBN5 Steady-On


LED with blue lens and light source
and 120V 60 Hz supply voltage

888-397-5353 USA

kele.com


105BM
105BX
105PM

ACCESSORIES
Wall-mount bracket (requires 105BX)
Surface-mount box
Pipe-mount base

PAGE
74,77,479-480
74,77,479-480
74,77,479-480

4.5"
(114 mm)

4.5"
(114 mm)

5"
(127 mm)

2"
(51 mm)

2.25"
(57 mm)

105PM Pipe Mount Attachment

5.25"
(133 mm)
6"
(152 mm)

105BX Outlet Box Attachment

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

4.5"
(114 mm)

105BM Mounting Bracket


(use with 105BX)

March
March
20142014

NEW!

ALARMS & INDICATION


XTRA-BRITE LED BEACONS
125XBR SERIES

DESCRIPTION

The Edwards 125XBR Class XBR XTRA-BRITE LED


beacons are UL and cUL listed dual mode signaling devices,
available in two versions, Steady-On/Flashing (125XBRM)
and Steady-On/Lightburst (125XBRZ). Both versions feature
a corrosion resistant Type 4X enclosure and can be panel
or conduit mounted. The lens is made of shatter resistant
polycarbonate. Both the 125XBRM and 125XBRZ beacons
are dual mode devices, maximizing application flexibility while
reducing inventory costs. It can also be panel-mounted using
the mounting gasket provided with the unit.

Available in 24 VDC or 120 VAC


Available with amber, blue, green, red or white lens
Available with gray or black base
Option for panel or conduit mounting
Available in dual mode Steady-On/Flashing LED or
Steady-On/Lightburst LED versions

ALARMS & INDICATION

FEATURES

125XBR
DIMENSIONS

SPECIFICATIONS
Supply Voltage
125XBRxx24Dx
125BRxx120Ax
Current
125XBRxx24Dx
125BRx120Ax
Color
Flash Rate
125XBRM
125XBRZ
Projected LED Life
Operating Temperature
Dimensions
Enclosure Rating
Mounting
Approvals
Weight
Warranty

24 VDC
120 VAC,50/60Hz
0.215A
0.108A
Amber, blue, clear, green, red

STEADY-ON/FLASHING (65 FPM)
STEADY-ON/LIGHTBURST (420FPM)
148,000 hours
-31 to 150F (-35 to 66C)
3.875"H3.875"H(98.4mm) X 3.25"W
(82.6mm)(98.4mm) X 3.25"W (82.6mm)
NEMA 4x
On 1/2" or 3/4" NPT conduit using a 1/2"
internal or 3/4" external conduit hub
cULus Listed
0.5lbs
18 months

Control panel
(Enclosure)
Yellow,
Not connected
(wire nut supplied)

MODEL
125XBR

125XBR

DESCRIPTION
Dual Mode XBR LED Beacons in NEMA 4X Enclosure
OPERATION
M
Steady-On/ Flashing LED
Z
Steady-On/ Lightburst
COLOR
A
Amber
B
Blue
G
Green
R
Red
W White
SUPPLY VOLTAGE
24D 24V DC
120A 120V AC @ 60 Hz
BASE COLOR
(BLANK)
Gray
B
Black
Z

18 Wire Leads

120A

Example: 125XBRZR120A Dual Mode XBR LED


Beacons in NEMA 4X Enclosure, with
Steady-On Lightburst, red LED, 120V AC
@ 60 Hz, and gray base

DC units; Red Positive (+)


AC units; Black Hot
DC units; Black negative (-)
AC units; White neutral
Wire Nuts
(Not Supplied)
Power Source
Wires

March 2014

3.25"
(82.6mm)

ORDERING INFORMATION

125XBR Series
LED Visual Indicator
Gasket
(supplied)

Locknut - 1.3625" O.D. (provided


for use when direct panel
mounting)

Double threaded for


panel mounting or
1/2" internal or
3/4" external
conduit mounting

WIRING

Locking Nut 1.3625" OD


(supplied)

3.875"
(98.4mm)

Gasket (provided for use


when direct panel mounting)

125GRD
CBR
WBR

WE MAKE IT EASY.

ACCESSORIES
Optional Gaurd for use with 125 Class Beacons
Corner Mount Bracket
Wall Mount Bracket

kele.com

888-397-5353 USA

75

ALARMS & INDICATION


XTRA-BRITE LED MULTI-STATUS INDICATOR
105XBRI SERIES
DESCRIPTION

ALARMS & INDICATION

The Edwards 105XBRi Series XTRA-BRITE LED MultiStatus Indicator is a heavy duty, reliable UL and cUL listed,
multi-color visual signaling device. It features a corrosion
resistant Type 4X enclosure that is UL listed for Marine use, and
can be panel or conduit mounted. The base is manufactured
from glass-reinforced thermoplastic polyester resin and the
double fresnel lens is made of shatter resistant polycarbonate.
The lights are available in 24 VDC and 120 VAC 50/60 Hz, in
either Red/Blue/Amber or Red/Green/Amber.

FEATURES
Available in 24V DC or 120V AC
Available in Red/Blue/Amber or Red/Green/Amber
Three mounting bases: 3/4" pipe mount attachment, outlet
box attachment, or wall mounting bracket
PLC compatible
XTRA-SAFE Technology enables status indication for
those who are color blind
Dip switch settings for use with or without external control
Immune to shock and vibration

SPECIFICATIONS
Supply Voltage
105XBRiRxA24D
105XBRiRxA120A
Current
105XBRiRxA24D
105XBRiRxA120A
Max. Off State Leakage
Current
Surge (inrush/duration)
105XBRiRxA24D
105XBRiRxA120A
LED Colors
Flash Mode
Flash Rate
Projected LED Life
Operating Temperature
Dimensions
Enclosure Rating
Mounting
Approvals
Weight
Warranty

105XBRi-RGA

DIMENSIONS
24 VDC
120 VAC, 50/60Hz

4.625"
(92mm)

0.15A
0.1A
5mA
28A/65uSeconds
28.5A/212uSeconds
Red/Green/Amber or Red/Blue/Amber
Dipswitch settings for use with or without
external control
XTRA-SAFE Mode; Red 240 FPM,
Amber120 FPM, Green or Blue 65 FPM
148,000 hours
31 to 150F (-35 to 66C)
4.5"W x 4.625"H (114 x 117 mm)
NEMA 4X
" pipe mount attachment, outlet box
attachment, or wall mounting bracket
UL & cUL Listed
1.4 lb(0.63 kg)
18 months

4.375"
4.625"
(111mm) (117mm)

4.5"
(114mm)

HAZARDOUS LOCATION RATINGS


Cat. No
105XBRIRGA24D
105XBRIRGA120A
105XBRIRBA24D
105XBRIRBA120A

76

888-397-5353 USA

kele.com

Class
l
ll
lll
l
ll
lll

Division
2
2

Group
A,B,C,D
F,G

2
2

A,B,C,D
F,G

Operating Temperature
T5 (100C, 212F)
T5 (100C, 212F)
T5 (100C, 212F)
T6 (85C, 185F)
T6 (85C, 185F)
T6 (85C, 185F)

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


XTRA-BRITE LED MULTI-STATUS INDICATOR
105XBRI SERIES

WIRING

105-LC Lens

Black (DC -) or White (AC neutral)


Red (DC + or AC hot for
Red LED activation)

Amber (DC + or AC hot for Amber LED


activation)

Blue with Green tracer


(DC + or AC hot for Blue or Green
LED activation (depending on model))

Dipswtich Settings:

Power source wires

Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Disabled

Applications WITH
a PLC or Controller*

*It is generally recommended that both dipswitches, SW1 and SW2,


be set to OFF for applications using an external Programmable Logic
Controller (PLC) or other external controller. A PLC or controller, however, can be used with any of the shown configurations.

(2) Screws to mount


105BX to the
mounting surface
Mounting
Surface

(Dipswitch located inside the unit)

ORDERING INFORMATION

MODEL
105XBRi

DESCRIPTION
LED Multi-Status Indicator in NEMA 4X Enclosure
COLORS
RGA Red, Green, Amber
RBA Red, Blue, Amber
SUPPLY VOLTAGE
24D 24 VDC
120A 120 VAC @ 50/60 Hz

105XBRi

RGA


105BM
105BX
105PM

24D

ALARMS & INDICATION

Wire Nuts
(not supplied)

Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Enabled
(Factory Default)

Example: 105XBRiRGA24D LED Multi-Status


Indicator in NEMA 4X Enclosure with
Red, Green, and Amber lens, and 24 VDC

ACCESSORIES
Wall-mount bracket (requires 105BX)
Surface-mount box
Pipe-mount base

PAGE
74,77,479-480
74,77,479-480
74,77,479-480

5"
(127mm)
4.5"
(114mm)
4.5"
(114mm)

2"
(51mm)

2.25"
(57mm)
5.25"
(133mm)
6"
(152mm)

105BM Mounting Bracket


(use with 105BX)

March 2014

4.5"
(114mm)

(4) 3/4"
Knockouts

0.34"
(9mm)
Diameter

105BX
Outlet Box Attachment

WE MAKE IT EASY.

105PM
Pipe Mount Attachment

kele.com

888-397-5353 USA

77

ALARMS & INDICATION


XTRA-BRITE LED MULTI-STATUS INDICATOR
125XBRI SERIES
DESCRIPTION

The Edwards 125XBRi Series XTRA-BRITE LED MultiStatus Indicator is a UL and cUL listed, multi-color visual
signaling device. It features a corrosion resistant Type 4X
enclosure and can be panel or conduit mounted. The base
is manufactured from a 33% glass filled nylon, providing
high resistance to heat and high chemical resistivity. The
lens is made of shatter resistant polycarbonate. The lights
are available in 24 VDC and 120 VAC 50/60 Hz, in either
Red/Blue/Amber or Red/Green/Amber.

ALARMS & INDICATION

FEATURES





Available in 24 VDC or 120 VAC


Available with gray or black base
Available in Red/Blue/Amber or Red/Green/Amber
Option for panel or conduit mounting
PLC Compatible
XTRA-SAFE Technology enables status indication for
those who are color-blind
Dip switch settings for use with or without external control
Immune to shock and vibration
Protective wire guard available, Cat. No. 125GRD

125XBRi

SPECIFICATIONS

DIMENSIONS

3.875"
(98.4mm)

Gasket (provided for use


when direct panel mounting)

Locknut - 1.3625" O.D. (provided


for use when direct panel
mounting)

Double threaded for


panel mounting or
1/2" internal or
3/4" external
conduit mounting

78

Supply Voltage
125XBRiRxA24Dx 24 VDC
125XBRiRxA120Ax 120 VAC, 50/60Hz
Current
125XBRiRxA24Dx 0.15A
125XBRiRxA120Ax 0.1A
Max. Off State Leakage Current
5 mA
Surge (inrush/duration)
125XBRiRxA24Dx 28.5A/65uSeconds
125XBRiRxA120Ax 28.5A/212uSeconds
LED Colors
Red/Green/Amber or Red/Blue/
Amber
Flash Mode
Dipswitch enabled
Flash Rate
XTRA-SAFE Mode, Red 240
FPM, Amber120 FPM, Green or
Blue 65 FPM
Projected LED Life
148,000 hours
Operating Temperature -31 to 150F (-35 to 66C)
Dimensions
3.25"W x 3.875"H (82.6 x 98.4mm)
Enclosure Rating
NEMA 4X
Mounting
Conduit or panel mount
Approvals
UL & cUL Listed
Weight
0.5 lbs (0.22 kg)
Warranty
18 months

3.25"
(82.6mm)

888-397-5353 USA

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


XTRA-BRITE LED MULTI-STATUS INDICATOR
125XBRI SERIES
WIRING

125XBRI Series Chameleon


LED Visual Indicator

Gasket
(supplied)

Locking Nut 1.3625" OD


(supplied)

(Blue or Green LED activation)


DC Units; Blue with green stripe, Positive (+)
AC Units; Blue with green stripe, Hot

Control panel

Wire nuts
(not supplied)

(Red LED activation)


(DC Units; Red positive (+)
AC Units Red Hot

DC Units; Black DC common (-)


AC Units; White AC neutral

Wire color corresponds with each indicated color.


Red wire = Red LED's
Yellow wire = Amber LED's
Blue with Green tracer wire = Green or Blue LED's

Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Enabled
(Factory Default)

Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Disabled

*It is generally recommended that both dipswitches, SW1 and SW2,


be set to OFF for applications using an external Programmable Logic
Controller (PLC) or other external controller. A PLC or controller, however, can be used with any of the shown configurations.

(Dipswitch located inside the unit)

ORDERING INFORMATION
MODEL
125XBRi

125XBRi


125GRD
CBR
WBR

March 2014

Applications WITH
a PLC or Controller*

ALARMS & INDICATION

(Amber LED activation)


DC Units; Amber Positive (+)
AC Units; Amber Hot

Dipswtich Settings:

DESCRIPTION
LED Multi-Status Indicator in NEMA 4X Enclosure
COLOR
RGA Red, Green, Amber
RBA Red, Blue, Amber
SUPPLY VOLTAGE
24D 24 VDC
120A 120 VAC @ 60 Hz
BASE COLOR
(BLANK)
Gray
B
Black
RGA

120A

Example: 125XBRi-RGA-120A LED Multi-Status


Indicator in NEMA 4X Enclosure, with red,
green, and amber LEDs, with 120 VAC @
60 Hz, and gray base

ACCESSORIES PAGE
Optional Guard for Use with 125 Class Beacons
Corner Mount Bracket
70-71
Wall Mount Bracket
70-71

WE MAKE IT EASY.

kele.com

888-397-5353 USA

79

ALARMS & INDICATION


LED STACKLIGHT
200 CLASS CLEARVIEW
DESCRIPTION

ALARMS & INDICATION

The 200 Class 70mm ClearView LED Stacklight is a


versatile, multi-mode signaling device that may contain up
to five light modules, or four light modules and one sounder
module in a single, integrated stack. The lens modules are
clear, and are available with red, amber, blue, green, yellow
and white LEDs in 24 VAC, 24 VDC and 120 VAC. The lenses
are made from a self-extinguishing polycarbonate material
and are scratch and impact resistant. Optional piezoelectric
and magnetodynamic sounder modules complement the
visual signals of the Stacklight, offering several audible
tones depending on the model chosen. The sound module
has been designed so that it is always in the top position
of the Stacklight. The 200 Class 70mm ClearView
LED Stacklight features an interlocking system for quick
assembly without any tools. It is available in gray or black
and offers multiple voltage ranges to provide solutions for
industrial applications, while also meeting machine builder
and OEM requirements.

270CLED

WIRING

FEATURES










24 VAC, 24 VDC and 120 VAC


Stackable up to five modules including sounder
Quick and simple assembly with NO tools required
Multi-Mode (Steady, Single, Double or Triple Flash)
Two optional sounders available; Piezoelectric: Six user
selectable tones, Magnetodynamic: 32 user selectable tones
Clear lens
LED light source
Available in Gray or Black
IP65 or IP54 available
cULus Listed
CE approved

4
3
2
1

On the power supply line, use appropriate


time-lag fuses according to the voltage.

V DC
V AC

() (+)

SPECIFICATIONS
Supply Voltage
Light Modules
24 VDC, 0.065A; 24 VAC, 0.075A to 0.085A

120 VAC/DC, 0.035A
Piezoelectric
Sound Modules
12 VAC/DC, 0.003A; 24 VAC/DC, 0.006mA;
48 VAC/DC,

0.013A; 120 VAC, 0.004A; 240 VAC, 0.01A
Magnetodynamic
Sound Modules
12 VAC, 0.12-0.95A; 12 VDC, 0.03-0.335A;
24 VAC
0.17-1.06A; 24VDC, 0.045-0.45A; 120VAC,
0.04-0.105A; 240 VAC, 0.025-0.06A
Color
White, red,green,blue, amber
Flash Mode
Steady on, Single (75FPM), Double
(85FPM), Triple (85FPM)
Horn Loudness
Piezoelectric
Sound Modules
12 VAC/DC, 72-79dB; 24 VAC/DC, 77-85dB

48 VAC/DC, 79-89dB; 120 VAC, 75-81dB
240 VAC, 78-87dB
Magnetodynamic
Sound Modules
12 VAC/DC, 86.5-103.5dB; 24 VAC/DC,
91-107dB;

120 VAC, 93-103dB; 240 VAC, 93-103.5dB

80

888-397-5353 USA

kele.com

Operating Temperature
Light Modules
-22 to 122F (-30 to 50C)
Piezoelectric Sound
Modules
-22 to 140F (-30 to 60C) at 12V to 48V;
-22 to 132.8F (-30 to 56C) at 120V to
240V
Magnetodynamic Sound
Modules
-22 to 140F (-30 to 60C) at 12V to 24V;
-22to 122F (-30 to 50C) at 120V to 240V
Dimensions
Base
1.89"H x 2.678" dia (48 x 68 mm)
Light Module
2.323"H x 2.953"dia (59 x 75 mm)
Sound Module
4.095"H x 2.953"dia (104 x 75 mm)
Enclosure Rating
NEMA 3R, 4X,IP66 rated base and light
modules, IP54 rated sound modules
Mounting
Wall mount or Surface mount
Weight
Base 0.83 lb (0.38 Kg)
Light Modules 0.81 lb (0.37 Kg)
Piezoelectric
Sound Modules
1.04 lb (0.47 Kg)
Magnetodynamic
Sound Modules
1.28 lb (0.58 Kg)
Approvals
cULus Listed, CE approved
Warranty
18 months

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


LED STACKLIGHT
200 CLASS CLEARVIEW

70MM PIEZOELECTRIC (PZO) ACOUSTIC MODULE DIP SWITCH SETTINGS

Sound Type

Diagram

12 VDC/VAC
dB
A
at 1m

F (Hz)1

24 VDC/VAC
dB
A
at 1m

48 VDC/VAC
dB
A
at 1m

120 VAC
dB
A
at 1m

240 VAC
dB
A
at 1m

on

Continuous reduced output

2
on

Continuous maximum output

50/60

0.003

75

0.006

81

0.013

83

0.004

75

0.010

81

50/60

0.003

79

0.006

85

0.013

89

0.004

81

0.010

87

50/60

0.003

72

0.006

77

0.013

79

0.004

76

0.010

78

50/60

0.003

77

0.006

84

0.013

86

0.004

81

0.010

85

50/60

0.003

74

0.006

79

0.013

81

0.004

76

0.010

79

50/60

0.003

78

0.006

85

0.013

87

0.004

81

0.010

85

on

2
on

Slow intermittent maximum output


on

Fast intermittent reduced output


1

2
on

Fast intermittent maximum output


1For AC voltages only

ALARMS & INDICATION

Slow intermittent reduced output

DIMENSIONS/ORDERING INFORMATION
BASE AND COVER

LIGHT MODULE

2.953"
(75mm)

2.835"
(72mm)

.788"
(20mm)

2.323" 2.717"
(59mm) (69mm)

3.11"
(79mm)

2.953"
(75mm)

2.323"
(59mm)

1.89"
(48mm)

2.678"
(68mm)

ACOUSTIC MODULE

4.567"
(116mm)

MODEL
270CLED

4.095"
(104mm)

LED LIGHT MODULES

DESCRIPTION
LED Stacklight Module
MODULE TYPE
S
Steady
M
Multimode
COLOR
A
Amber
B
Blue
G
Green
R
Red
Y
Yellow
W
White
SUPPLY VOLTAGE
24AD 24V AC/DC
120A 120V AC
BASE COLOR
(BLANK)
Gray
B
Black

1/2" NPT

270CLED

120A

Example: 270CLEDMW120A LED Stacklight Module


with multimode module, white LED,
120 VAC, and gray base

2.953"
(75mm)

SOUND MODULES
Piezoelectric Sounder
270PZO1248AD
12-48 AC/DC, Gray
270PZO1248ADB
12-48 AC/DC, Black
270PZO120240A
120-240 VAC, Gray
270PZO120240AB
120-240 VAC, Black
Magnetodynamic Sounder
270MDA1224AD
270MDA1224ADB
270MDA120A
270MDA120AB
270MDA240A
270MDA240AB

March 2014

12-24 VAC/DV, Gray


12-24 VAC/DV, Black
120 VAC, Gray
120 VAC, Black
240 VAC, Gray
240 VAC, Black


270FLXT
270FMLADAPT
270JBX**
270KIT**
270SSXT100
270SSXT200
270SSXT400
270TEP**
270THF**
270TWM**
270TWM2**

ACCESSORIES
270 Flexible Steel Extension Stem - 370mm
270 Female Adapter Base - Gray
Junction Box - Gray
Footing with Extension - Gray
270 Stainless Steel Extension Stem - 100mm
270 Stainless Steel Extension Stem - 200mm
270 Stainless Steel Extension Stem - 400mm
Threaded Extension Pole 100mm - Gray
Threaded Footing - Gray
Threaded Wall Mount - Gray
Double Threaded Wall Mount - Gray

**NOTE: Add B to the end of the model number for black unit.

WE MAKE IT EASY.

kele.com

888-397-5353 USA

81

ALARMS & INDICATION


75 MM TOWER LIGHTS
TWS SERIES
DESCRIPTION

ALARMS & INDICATION

The TWS Series Tower Lights enable stacking of up


to five signaling devices. Each device has its own set of
contacts. Starting with a bottom module, up to five devices
can be added in any combination of continuous and flashing
incandescent lights, continuous and flashing LED lights,
and Xenon strobes. Each stack can be capped with a
horn. Each light comes in a variety of colors, and all lamps
are replaceable. Several wall- and pedestal-mounting
configurations are available.

OPERATION



Horns
IP20 upward mount
IP24 downward moun
Ratings IP66

Stack with
TWS-BS

Stack with
TWS-BP1

Stack with
TWS-KIT
Two stacks with
TWS-BP2

WIRING
5

4
3
2
1

5
4
3
2
1

C
VDC +
(VAC)

SPECIFICATIONS
Supply Voltage
Voltage Range
Power
Light module
Horn module

12-24 VAC/VDC, 24-240 VAC


24 VAC/ VDC, 110 VAC, 24 VAC , 24
VDC
5W 12-120 VAC/VDC (7W 240 VAC)
12V-2.7 mA, 24V-6 mA, 110V-4
mA,240V-8.5 mA
Blue, amber,red,green, yellow, clear

Color
Flash Rate
Incandescent LED
110 FPM 20 FPM
Strobe
65 FPM 10 FPM(24 VAC/DC)

90 FPM 20 FPM (110/240 VAC)
Horn Loudness
Medium, 76-86 dB
Operating Temperature -22 to 140F (-30 to 60C)

82

888-397-5353 USA

kele.com

Strobe
Dimensions
Base
Light
Horn
Mounting
Enclosure
Horn

Approvals
Warranty

14 to 122F (-10 to 50C)



2.68"H x 2.95" dia (6.8 x 7.5 cm)
2.72"H x 2.95" dia (6.9 x 7.5 cm)
3.11"H x 2.95" dia (7.9 x 7.5 cm)
Wall, two holes; surface, four holes;
2.13" (5.4 cm) centers
IP66
IP20 upward mount
Ip 24 downward mount
CE UL Listed File E194312
18 months

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


75 MM TOWER LIGHTS
TWS SERIES

ORDERING INFORMATION

Steps

Direction

Part Number

Description

Select
Module
and Cap
(1 required)

TWS-BC

Bottom module and cap

Select
Mounting
Base
(1 required)

TWS-BS

Base with gasket

TWS-BP1

Single wall-mount base


Double wall-mount base

TWS-KIT

Base and stem extension

Module Voltage
Range

Color

Continuous
Incandescent

Flashing
Incandescent

24 VAC

BLUE

TWS-F1G

TWS-L1G

24 VDC

BLUE

TWS-F1N

TWS-L1N

110 VAC

BLUE

TWS-F1A

Continuous
LED

Flashing
LED

Strobe

TWS-FL1G

TWS-LL1G

TWS-X1G

TWS-FL1N

TWS-LL1N

TWS-X1N

TWS-L1A

TWS-FL1A

TWS-LL1A

TWS-X1A
TWS-X2G

Part Number

Select
Lighting
Modules
(5 maximum)

Select Horn
(1 maximum)


691-K0A
DCP-1.5-W
DCPA-1.2
TWS-BA15D-A
TWS-BA15D-G
TWS-BA15D-N
TWS-LED1-A
TWS-LED1-G
TWS-LED1-N
TWS-LED2-A
TWS-LED2-G
TWS-LED2-N
TWS-LED3-A
TWS-LED3-G
TWS-LED3-N
TWS-LED4-A
TWS-LED4-G
TWS-LED4-N
TWS-LED5-A
TWS-LED5-G
TWS-LED5-N
TWS-LRX2J

March 2014

24 VAC

AMBER

TWS-F2G

TWS-L2G

TWS-FL2G

TWS-LL2G

24 VDC

AMBER

TWS-F2N

TWS-L2N

TWS-FL2N

TWS-LL2N

TWS-X2N

110 VAC

AMBER

TWS-F2A

TWS-L2A

TWS-FL2A

TWS-LL2A

TWS-X2A

24 VAC

RED

TWS-F3G

TWS-L3G

TWS-FL3G

TWS-LL3G

TWS-X3G

24 VDC

RED

TWS-F3N

TWS-L3N

TWS-FL3N

TWS-LL3N

TWS-X3N

110 VAC

RED

TWS-F3A

TWS-L3A

TWS-FL3A

TWS-LL3A

TWS-X3A

24 VAC

GREEN

TWS-F4G

TWS-L4G

TWS-FL4G

TWS-LL4G

TWS-X4G

24 VDC

GREEN

TWS-F4N

TWS-L4N

TWS-FL4N

TWS-LL4N

TWS-X4N

110 VAC

GREEN

TWS-F4A

TWS-L4A

TWS-FL4A

TWS-LL4A

TWS-X4A
TWS-X5G

24 VAC

YELLOW

TWS-F5G

TWS-L5G

TWS-FL5G

TWS-LL5G

24 VDC

YELLOW

TWS-F5N

TWS-L5N

TWS-FL5N

TWS-LL5N

TWS-X5N

110 VAC

YELLOW

TWS-F5A

TWS-L5A

TWS-FL5A

TWS-LL5A

TWS-X5A

24 VAC

CLEAR

TWS-F6G

TWS-L6G

CLEAR

TWS-F6N

TWS-L6N

TWS-X6G

24 VDC
110 VAC

CLEAR

TWS-F6A

TWS-L6A

TWS-X6A

24 VAC

TWS-AG

24 VDC

TWS-AN

110 VAC

TWS-AA

ALARMS & INDICATION

TWS-BP2

TWS-X6N

ACCESSORIES
Control transformer, 120:24 VAC, 40 VA, Class 2
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC In to 24 VAC/24 VDC Out
110VAC Replacement IC Lamp
24 VAC Replacement IC Lamp
24 VDC Replacement IC Lamp
110 VAC Blue replacement LED
24 VAC Blue replacement LED
24 VDC Blue replacement LED
110 VAC Amber replacement LED
24 VAC Amber replacement LED
24 VDC Amber replacement LED
110 VAC Red replacement LED
24 VAC Red replacement LED
24 VDC Red replacement LED
110 VAC Green replacement LED
24 VAC Green replacement LED
24 VDC Green replacement LED
110 VAC Yellow replacement LED
24 VAC Yellow replacement LED
24 VDC Yellow replacement LED
Universal Xenon replacement- requires solder connection

WE MAKE IT EASY.

kele.com

888-397-5353 USA

83

ALARMS & INDICATION


OPERATOR STATIONS
ESB SERIES
DESCRIPTION

The ESB Series Operator Stations offer a highly visible


method to shut down equipment, initiate alarms, or give a
controller input during emergency conditions. Operation
occurs with the breaking of a lens, and then pushing the red
push-button inside. Both break-lens to release button and
field replacement lens are available.

ALARMS & INDICATION

FEATURES




ESB-M1F-BLR-BS

Highly visible yellow/black background


UL listed for Category NKCR, File #E352651
Various NEMA rated enclosures
Red push-button operators
1 N.O. and 1 N.C. contact included

ESB-M3S-BLP-CS

SPECIFICATIONS
Supply Voltage
Contact Rating
A600
Q600
Contact Configuration

M4S

24 VAC, 120 VAC

10A, 600 VAC


2.5A, 600 VDC
4 Maintained or 6 Momentary
maximum
Mechanical Life
Contact 10 million operations
Contact Type
Self-cleaning silver contacts
Contact Resistance
<25 m
Operating Temperature -13 to 158F (-25 to 70C)
Storage Temperature -22 to 185F (-30 to 85C)
Dimensions
M1S, M2S, M3S

M1F
Enclosure Rating
Approvals
Weight
M1S
M2S,M1F
M3S
M4S
Warranty

5.91"H x 5.91"D x 4.72"D


(15 x 15 x 12 cm)
5.5"H x 5.5"W x 4"D
(14 x 14 x 10.2 cm)
NEMA 1, 3R, 4, 4X, 12, 13
UL Listed file # E352651, NKCR,
cUL
2.63 lb (1.19 kg)
2.55 lb (1.16 kg)
2.83 lb (1.28 kg)
3.95 lb (1.79 kg)
1 year

4"H x 4" W x 4"D


(10.2 x 10.2 x 10.2 cm)

WIRING

TOP

1NO-1NC
Note: Typical contact connection
(4 momentary or 6 maintained maximum)

84

888-397-5353 USA

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


OPERATOR STATIONS
ESB SERIES

ORDERING INFORMATION

Model

Description

ESB

Break-Lens Operator Station (UL NKCR)


Enclosure

NEMA 1 Metal enclosure, surface mount

M3S

NEMA 3R Metal enclosure, surface mount

M2S

NEMA 12,13 Metal enclosure, surface mount

M4S

NEMA 4,12 Metal Enclosure, surface mount

M1F

NEMA 1 Metal enclosure, flush mount


Button Style
BLR

Break Lens to Release Button model with red momentary push button

BLP

Break Lens - Push Button model maintained operator


Legend

ESB


ES-LENS
ES-NC
ES-NO

March 2014

M1S

BLP

BS

Boiler Shut-down

CS

Chiller Stop

FN

Exhaust Fan

HS

HVAC Shut-down

PO

Power Off

RP

Refrigerant Purge

SD

Shut Down

SO

Shut Off

ST

Stop

VP

Ventilation Stop

VT

Ventilation Start

XX*

Custom Legend

CS

*18 character max, no color changes, no font changes,


no company logos.
Example: ESB-M1S-BLP-CS Break-Lens Operator Station,
NEMA 1 metal enclosure, surface mount, maintained
Break Lens Push Button operator, labeled as Chiller Stop

ALARMS & INDICATION

M1S

ACCESSORIES PAGE
Replacment Lens for ESB series Operator Stations
Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP
Emergency Operator Stations
98
Normally Open Contact Block for Non-illuminated ESM, ESB, and
ESP Operator Stations
98

WE MAKE IT EASY.

kele.com

888-397-5353 USA

85

ALARMS & INDICATION


EMERGENCY OPERATOR STATIONS
ESM SERIES
DESCRIPTION

The E-Stop ESM Series Emergency Operator Stations offer a


highly visible method to shut down equipment, initiate alarms,
or give a controller input during emergency conditions.
Operation is with the push of a red 40mm mushroom-head
push-button. The button may be reset with a pull or twist of
the mushroom head, depending on the button style.

ALARMS & INDICATION

FEATURES

ESM-M1S-PP0-BS

Highly visible yellow/black background


UL listed for Category NISD Emergency Stop Devices,
File #E348889
Various NEMA rated enclosures
40mm Red Mushroom Operators
1 N.O. and 1 N.C. contact included

ESM-NXS-PP0-VT

SPECIFICATIONS
Supply Voltage
Contact Rating
A600
Q600
Contact Configuration

M3S

24 VAC, 120 VAC

10A, 600 VAC


2.5A, 600 VDC
4 Maintained or 6 Momentary
maximum
Mechanical Life
Contact 10 million operations
Contact Type
Self-cleaning silver contacts
Contact Resistance
<25 m
Operating Temperature -13 to 158F (-25 to 70C)
Storage Temperature -22 to 185F(-30 to 85C)
Dimensions
M1S, M2S
4"H x 4"DW x 3"D
(10.2 x 10.2 x 7.6 cm)
NXS
4.45"H x 2.87" W x 3.11"D
(10.2 x 7.6 x 7.9 cm)
SXS
3.5"H x 3.25"W x 2.75"D
(8.9 x 8.3 x 7.1 cm)

M1F
Enclosure Rating
Approvals
Weight
M1S
NXS
M2S
SXS
M3S
M1F
Warranty

4"H x 4" W x 4"D


(10.2 x 10.2 x 10.2 cm)
5.5"H x 5.5"W x 3"D
(14 x 14 x 7.6 cm)
NEMA 1, 3R, 4, 4X, 12, 13 availiable
UL Listed NISD File# E348889, CSA,
NEMA
1.84 lb (0.84 kg)
1.93 lb (0.88 kg)
2.30 lb (1.04 kg)
1.90 lb (0.86 kg)
2.95 lb (1.34 kg)
2.39 lb (1.03 kg)
1 year

WIRING
PP0, PT0, PK

PTI24

TOP

1 NO-1NC
Note: Typical contact connection

86

888-397-5353 USA

kele.com

1NO-1NC
Note: Typical contact connection
(4 momentary or 6 maintained maximum)

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


EMERGENCY OPERATOR STATIONS
ESM SERIES

ORDERING INFORMATION

Model

Description

ESM

Maintained Emergency Operator Station (UL NISD)

Enclosure

NEMA 1 Metal enclosure, surface mount

NXS

NEMA 4X,12 Non-metal enclosure, surface mount

M2S

NEMA 12,13 Metal enclosure, surface mount

SXS

NEMA 4X Stainless steel enclosure, surface mount

M3S

NEMA 3R Metal enclosure, surface mount

M1F

NEMA 1 Metal enclosure, flush mount


Button Style
PP0

Red maintained 40mm mushroom (push-pull)

PT0

Red maintained 40mm mushroom (push-twist)

PTL24*

Illuminated 24V red maintained 40mm mushroom (push-twist, lamp included)

PK0

Red maintained 40mm mushroom (push- key release)

ALARMS & INDICATION

M1S

Legend
BS

Emergency - Boiler Shut-down

CS

Emergency - Chiller Stop

FN

Emergency - Exhaust Fan

HS

Emergency- HVAC Shut-down

PO

Emergency - Power Off

RP

Emergency - Refrigerant Purge

SD

Emergency - Shut Down

SO

Emergency - Shut Off

ST

Emergency - Stop

VP

Emergency - Ventilation Stop

VT

Emergency - Ventilation Start

XX**

Custom Legend
*Can only be used with M1S or M1F enclosure
**18 character max, no color changes, no font changes,
no company logos.

ESM

ES-KEY
ES-NC
ES-NO

March 2014

M1S

PP0

CS

Example: ESM-M1S-PP0-CS Maintained


Emergency Operator Station, NEMA1
metal enclosure, surface mount, Red
maintained 40mm push-pull mushroom,
labeled as Chiller Stop


ACCESSORIES
Replacement Key for PK0 option, ESM and ESP series
Normally Closed Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations
Normally Open Contact Block for Non-illuminated ESM, ESB, and ESP Emergency Operator Stations

WE MAKE IT EASY.

kele.com

PAGE
87,89
85,87,89
85,87,89

888-397-5353 USA

87

ALARMS & INDICATION


EMERGENCY OPERATOR STATIONS
ESP SERIES
DESCRIPTION

The E-Stop ESP Series Emergency Operator Stations offer a


highly visible method to shut down equipment, initiate alarms,
or give a controller input during emergency conditions. The
ESP Series consists of a stainless steel plate with a 40mm
mushroom head push-button. The button may be reset with a
pull or twist of the mushroom head, depending on the button
style.

ALARMS & INDICATION

FEATURES
Stainless steel plate mounted
Highly visible yellow/black background
UL listed for Category NISD Emergency Stop Devices,
File #E348889
40mm Red Mushroom Operators
1 N.O. and 1 N.C. contact included

ESP-PK0-SO

ESP-PP0-HS

SPECIFICATIONS
Supply Voltage
Contact Rating
A600
Q600
Contact Configuration

Storage Temperature
Dimensions

24 VAC, 120 VAC

10A, 600 VAC


2.5A, 600 VDC
4 Maintained or 6 Momentary
maximum
Mechanical Life
Contact 10 million operations
Contact Type
Self-cleaning silver contacts
Contact Resistance
<25 milli ohms
Operating Temperature -13 to 158F (-25 to 70C)

Enclosure Rating
Approvals
Weight
Warranty

-22 to 185F (-30 to 85C)


4.5"H x 2.75"W x 0.63"D
(11.4 x 7 x 1.6 cm)
NEMA 1, 3R, 4, 4X, 12, 13
UL Listed NISD File# E348889
0.58 lb (0.26kg)
1 year

WIRING
PP0, PT0, PK

PTI24

TOP

1 NO-1NC
Note: Typical contact connection

88

888-397-5353 USA

kele.com

1NO-1NC
Note: Typical contact connection
(4 momentary or 6 maintained maximum)

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


EMERGENCY OPERATOR STATIONS
ESP SERIES

ORDERING INFORMATION

Model

Description

ESP

Plate-mounted Emergency Operator Station (UL NISD)

Button Style

Red maintained 40mm mushroom (push-pull)

PT0

Red maintained 40mm mushroom (push-twist)

PTL24

Illuminated 24V Red maintained 40mm mushroom (push-twist, lamp included)

PK0

Red maintained 40mm mushroom (push- key release)


Legend
BS

Emergency - Boiler Shut-down

CS

Emergency - Chiller Stop

FN

Emergency - Exhaust Fan

HS

Emergency- HVAC Shut-down

PO

Emergency - Power Off

RP

Emergency - Refrigerant Purge

SD

Emergency - Shut Down

SO

Emergency - Shut Off

ST

Emergency - Stop

VP

Emergency - Ventilation Stop

VT

Emergency - Ventilation Start

XX*

Custom Legend

ALARMS & INDICATION

PP0

*18 character max, no color changes, no font changes,


no company logos.
ESP


ES-KEY
ES-NC

ES-NO

March 2014

PP0

CS

Example: ESP-PP0-CS Plate mounted Emergency Operator


Station. Red Maintained Push-Pull button labeled as Chiller
Stop.

ACCESSORIES PAGE
Replacement Key for PK0 option, ESM and ESP series
98
Normally Closed Contact Block for Non-illuminated ESM, ESB, and
ESP Emergency Operator Stations
98
Normally Open Contact Block for Non-illuminated ESM, ESB, and
ESP Emergency Operator Stations
98

WE MAKE IT EASY.

kele.com

888-397-5353 USA

89

ALARMS & INDICATION


OPERATOR STATIONS
ST120 SERIES

Pilla Electrical
Products, Inc.

DESCRIPTION

ALARMS & INDICATION

ST120 Series Operator Stations offers a means of disconnect to


shut down equipment and/or initiate alarms during emergency
conditions. Contacts are rated 600V @ 10A AC and 2.5A DC. All
models carry a one-year warranty. UL file is E158147.

ST120-SN4XNM-PO

ST120-FN1-BP2-RPG

ST120SL-RP2-VS

ST120-SN3R-BP2-CS

ST120SL-N1-BS

ORDERING INFORMATION
PUSH-BUTTON OPERATION
MODEL DESCRIPTION
ST120SL Complete push-pull emergency operator station (contacts not included)
Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 4X and 12 nonmetallic surface-mount box
F
Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 4 and 12 all-metal flush-mount box
FN1 Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 1 all-metal flush-mount box
N1 Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset NEMA 1 all-metal surface-mount box
RP1 Red Raised Lid - Push Button padlockable solid lid over momentary flush round push button
RP2 Red Raised Lid - Push Button padlockable solid lid over maintained flush round push button
LEGENDS
BS
EMERGENCY - BOILER SHUT-DOWN
CS
EMERGENCY - CHILLER STOP
FAN
EMERGENCY - EXHAUST FAN
HS
EMERGENCY - HVAC SHUT-DOWN
PO
EMERGENCY - POWER OFF
RPG
EMERGENCY - REFRIGERANT PURGE
SD
EMERGENCY - SHUT DOWN
SO
EMERGENCY - SHUT OFF
ST
EMERGENCY - STOP
VS
EMERGENCY - VENTILATION STOP
VSTART EMERGENCY - VENTILATION START
BREAK-LENS OPERATION
MODEL
ST120

DESCRIPTION
Complete break-lens emergency operator station (spare lens included, contacts not included)
FN1
FN4
SN1
SN3R
SN4
SN4XNM


PILCLHCOV1
PILCLHCOV5
PILENS
PILNCCB
PILNOCB

NEMA 1 all-metal flush-mount box


NEMA 4 and 12 all-metal flush-mount box
NEMA 1 all-metal surface-mount box
NEMA 3R rainproof all-metal surface-mount box
NEMA 4 and 12 all-metal surface-mount box
NEMA 4X non-metalic surface-mount box
Red Break Lens to Release Button model (use normally closed contact to close circuit when button releases)
BP1 Red Break Lens - Push Button model, momentary operator
BP2 Red Break Lens - Push Button model, maintained operator
Break Lens - Operate Switch two-position selector switch, maintained both positions, short lever
P1
P3
Break Lens - Operate Switch three-position selector switch, maintained all positions, short lever
LEGENDS - See above

ACCESSORIES
Clear hinged cover for push-pull model and ST120SN4XNM
Clear hinged cover for break-lens model except ST120SN4XNM
Replacement lens for break-lens model
N.C. stackable contact block for MST1 stations
N.O. stackable contact block for MST1 Stations

PAGE
90,92
90-92
90-92

Notes: Six contact blocks max (2 rows of 3) may be used on each break glass operator station and the -FN1 and -N1
modesl of push-button operation stations. The - model and F model push-button stations can only take three contact
blocks (1 row of 3).
All units use normally open contacts to close circuit or normally closed to open circuit (except "Break Glass of Release
Button" model).

90

888-397-5353 USA

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


PLATE MOUNTED OPERATOR STATIONS
WPS SERIES

Pilla Electrical
Products, Inc.

DESCRIPTION

The WPS Series Plate-mounted Operator Stations mount on


a single-gang wall box or a standard handy box and come
with brushed stainless steel plate. They are rated NEMA 1 for
indoor applications. Many options are available for the WPS
Series in addition to the models shown on our catalog page.

FEATURES

Mounted on brushed stainless steel wall plate


Order contacts separately for wiring flexibility
Hinged lockout lids options
Special configurations and labeling are available
Single-gang wall or handy box mounting
Contacts rated 600V at 10A AC and 2.5A DC
One-year warranty
UL File E158147

WPS-MP-BS-CLM

WPS-KR-VS

WPS-BR-PO

ALARMS & INDICATION

WPS-MO-PO-DLM

WPS-RP2-HS

ORDERING INFORMATION
MODEL DESCRIPTION
WPS Wall plate, box mounted emergency operator station (order contacts separately)
BUTTON STYLE
MO Red momentary 40 mm mushroom
MP Red maintained 40 mm mushroom (push-pull) labeled Pull to Reset
TW Red maintained 40 mm mushroom (push-turn to reset) labeled Turn to Reset
KR
Red maintained key release 40 mm mushroom with two keys, key required to reset only
RP1 Red Raise Lid - Push Button padlockable solid lid over momentary flush round push button
RP2 Red Raise Lid - Push Button padlockable solid lid over maintained flush round push button
CP1 Red Raise Lid - Push Button padlockable clear lid over momentary flush round push button
CP2 Red Raise Lid - Push Button padlockable clear lid over maintained flush round push button
BR
Break Lens model with hammer (NC/NO contacts included)
LEGENDS
CS
EMERGENCY - CHILLER STOP
PO
EMERGENCY - POWER OFF
BS
EMERGENCY - BOILER SHUT-DOWN
HS
EMERGENCY - HVAC SHUT-DOWN
VS
EMERGENCY - VENTILATION STOP
ST
EMERGENCY - STOP
SD
EMERGENCY - SHUT-DOWN
VSTART EMERGENCY - VENTILATION START
SO
EMERGENCY - SHUT-OFF
CLM Clearhinged lockout lid for use with MO, MP, TW, KR 40mm mushroom button
DLM Hinged lockout lid for use with MO 40mm mushroom button.
Requires lid to be lifted in order to automatically release/extend mushroom
device.
Example: WPS-MP-VSTART Wall plate operator station red maintained
push-pull button labeled Ventilation Start
WPS


PILCLM
PILNCCB
PILNOCB
PILRPKEY
PILBRLENS
Note:

March 2014

MP

VSTART

RELATED PRODUCTS
Clear cover for MO, MP, TW, KR stations
N.C. stackable contact block
N.O. stackable contact block
Replacement key for WPS-KR series, specify model and key number when ordering
Replacement lenses for WPSBR models only (3/pkg)
Three contact blocks can be used for a depth of 1-5/8" (42 mm).
Three more can be added for a depth of 2-5/8" (67 mm).

WE MAKE IT EASY.

kele.com

PAGE
103
103

888-397-5353 USA

91

ALARMS & INDICATION


POWER CONTROL STATIONS
MNST AND MST1 SERIES

Pilla Electrical
Products, Inc.

DESCRIPTION

The MNST and MST1 Series Power Control Stations offer


two push-button control for a variety of HVAC and other
equipment. It comes with two round push-buttons (one green
and one red) and one set of normally open and normally
closed contacts.

FEATURES

ALARMS & INDICATION

Models with non-metallic NEMA 4X & 12 enclosures for

outdoor and wet locations


Models with metal NEMA 1 enclosures for indoor and dry
locations
Bold, reflective legends on white enamel aluminum face
plate
Two maintained/interlocked push buttons on MNST models
Two momentary/non-interlocked ormomentary/
noninterloced, push buttons on MST1 models
UL listed, File E158147

MNSTN1SS with
PILCLHCOV1 COVER

MNSTLGSS

SPECIFICATIONS
Contact Rating

600V, 10A continuous @120 VAC, 0.5A


continuous @24 VDC
1NC, 1 NO
-13 to 158F (-25 to 70C)
-40 to 158F (-40 to 70C)

Contact Configuration
Operating Temperature
Storage Temperature
Conduit Connection
MNSTxxN1x/MST1xxN1x Knockouts in top, bottom & back for 1/2"
(1.27 cm) and 3/4" conduit
Mounting
MNSTx/MST1x
Surface mount, external mounting tabs
top and bottom
MNSTxxN1x/MST1xxN1x Surface mount, two mounting holes in the
back

Approvals
Enclosure Rating
MNSTx/MST1x
MNSTxxN1x/MST1xxN1x
Dimensions
MNSTx/MST1x

UL Listed file #E158147, cUL Listed


NEMA 4X/4/12/3/1, Nonmetallic backbox
NEMA 1, Metal backbox

4"W x 4"H x 2.4"D


(10.16 x 10.16 x 6.09 cm)
MNSTxxN1x/MST1xxN1x 4"W x 4"H x 3"D
(10.16 x 10.16 x 7.62 cm)
Weight
MNSTx/MST1x
1 lb (0.45 kg)
MNSTxxN1x/MST1xxN1x 2.5 lbs (1.13 kg)
Warranty
1 year

ORDERING INFORMATION
Model Description
MNST Power control stations, two maintained/interlocked pushbuttons, one set of NO/NC specialty contact blocks included
MST1 Power control stations, two momentary/non-interlocked pushbuttons, one set of NO/NC contact blocks included
(BLANK) Default main legend "POWER CONTROL SWITCH"
LB
Main legend "BOILER"
LC
Main legend "CHILLER"
LE
Main legend "EXHAUST FAN"
LF
Main legend "FUEL"
LG
Main legend "GENERATOR"
LH
Main legend "HVAC"
LP
Main legend "POWER"
LV
Main legend "VENTILATION"
(BLANK) NEMA 4X/4/12/3 non-metallic grey surface-mount box for outdoor or indoor/wet locations
N1
NEMA 1 metal grey surface-mount box for indoor/dry locations
SS "START" and "STOP" pushbuttons
OO "ON" and "OFF" pushbuttons
CI Custom inscriptions on pushbuttons (customer to provide inscription details)
MNST

LB

N1

SS

Example: MNSTLBN1SS Boiler control station in NEMA 1 metal housing with start
and stop pushbuttons


ACCESSORIES
PILCLHCOV1
Clear
hinged
cover
for
push-pull
model and ST120SN4XNM
ACCESSORIES
closed
contact
block for MNST stations only
PILNCCB PILNCMN N.C.Additional
stackablespecialty
contactnormally
block for
MST1
stations
Additional specialty normally open contact block for MNST stations only
PILNCMN PILNOMN Additional
specialty Normally Closed contact block for MNST stations only
PILCLHCOV1 Clear hinged cover, tamperproof
PILNOCB PILNCCB N.O.N.C.
stackable
contact
block
stackable
contact
blockfor
forMST1
MST1 Stations
stations
N.O. stackable
contact
block Open
for MST1
stations
PILNOMN PILNOCB Additional
specialty
Normally
contact
block for MNST stations only

92

888-397-5353 USA

kele.com

PAGE
90,92
90-92
90-92

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


3-1/2 DIGIT LCD PANEL DISPLAY
VPI SERIES

DESCRIPTION

The VPI Series is a voltage (0-5V, 0-10V) input 24 VDC powered,


3-1/2 digit display. The VPI Series uses a voltage signal of 0-5 or
0-10 VDC that can be scaled to a span of 2000 digits within a range
of -1999 to 1999. This display also features jumper selectable, built-in
engineering units. The VPI-4 offers large, easy to read 1" (2.54 cm)
digits.
FEATURES

VPI-1-C-G
(typical panel mount)

VPI-1-C-WMB

0-5 or 0-10 VDC input signal


3-1/2 digit, easy to read LCD display (VPI-1, VPI-4)
4-1/2 digit, easy to read LCD display (VPI-3)
Available in black amber, green and red digits
Snap-in panel mounting
NEMA 4 enclosure available
Precalibrated before shipping
Positive-to-negative indication
Jumper selectable engineering unit display of F, C, PSI, %

ALARMS & INDICATION

VPI-4

SPECIFICATIONS
Supply Voltage
Black
Color
Input Signal
Input Impedance
Accuracy
Digit Count
VPI-1, VPI-4
VPI-3
Digit Size
VPI-1, VPI-3C
VPI-4
Digit Span (VPI-3)
Decimal Point (VPI-3)
Display Color
Zero Range (VPI-3)
Operating Humidity
Operating Temperature
Panel Clearance
Cutout Requirement
VPI-1C
VPI-4
Dimensions
VPI-1C, VPI-3C
VPI-4
E (NEMA4X)
WMB
Enclosure Rating
Approvals
Weight
Warranty

VPI-1-C-R-E

24 VDC @ 10 mA
24 VDC @ 35 mA
0-5 VDC or 0-10 VDC
400 k
0.1% of scale plus one digit

APPLICATION
Temperature
Humidity
Pressure

3-1/2 digits
4-1/2 digits

VPI-1-C-R-E-DBL

Gallons per minute


Voltage
Kilowatt demand

WIRING

0.5" (1.27 cm)


1.0" (2.54 cm)
2000 digits (20000 digits)
Three positions or none, Four positions or none
Black, amber, green, red
-1999 to 1999, -19999 to 19999
95% non-condensing
32 to 122F (0 to 50C)
1.0" (5.08 cm)

Power supply
24 VDC

Power connection only


required for amber, green,
or red display.

Voltage
input

1.00"H x 2.40"W (2.54 x 6.10 cm)


1.77"H x 3.62"W (4.5 x 9.2 cm)
1.10"H x 2.51"W (2.82 x 6.38 cm)
1.89"H x 3.62"W (4.8 x 9.6 cm)
6.0"H x 6.0"W x 3"D (15.2 x 15.2 x 7.6 cm)
2.12"H x 3.12"W x 1.75"D (5.4 x 7.94 x 4.45 cm)
NEMA 1, NEMA 4X
RoHS
4 oz (113g)
1 year

+
PWR

+
SIG

BL

5V
10V
OFFSET

* PWR- and SIGmust be externally


connected together

5V Span pot
10V Span pot
Offset (ZERO) pot

VPI

ORDERING INFORMATION
Displays are custom calibrated at no charge
and require specification of input scale (VDC),
range, engineering units, and decimal point
placement.

MODEL
VPI-4
VPI-1C
VPI-3C

VPI-1C


DCP-1.5-W
DCPA-1.2
GP-3420
GP-3430

March 2014

DESCRIPTION
3-1/2 digit panel display*, 1'' (2.54 cm) digits
3-1/2 digit panel display*, 0.5'' (1.27 cm) digits
4-1/2 digit panel display*, 0.5'' (1.27 cm) digits

3-1/2 digit display with black digits


A 3-1/2 digit display with amber digits
G 3-1/2 digit display with green digits
R 3-1/2 digit display with red digits

No enclosure
E
LCD panel display with NEMA 4X enclosure (VPI-1C and VPI-3C only)
WMB
LCD panel display with small enclosure (VPI-1C and VPI-3C only)
E-DBL Two LCD panel displays in one NEMA 4X enclosure (VPI-1C and VPI-3C only)
A

E-DBL

Example: VPI-1C-A-E-DBL Two amber 3-1/2 digit


displays mounted in a single enclosure

RELATED PRODUCTS
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC In to 24 VAC/24 VDC Out
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm)
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm)

WE MAKE IT EASY.

kele.com

PAGE
995
93,97-99
93,97-99

888-397-5353 USA

93

ALARMS & INDICATION


PANELPILOT SMART GRAPHICAL DISPLAY
SGD-24, -28
DESCRIPTION

ALARMS & INDICATION

The PanelPilot Smart Graphics Display is a configurable


panel-mount volt meter with selectable graph colors, input
signal scales, and meter display types. It can be used
to display any proportional control or transmitter signal
represented by a voltage span within 0 to 40 VDC. It is easily
and quickly field-configured using simple software, via a
USB cable, or is available preconfigured from Kele. It has
a customizable splash screen and comes in a 2.4" or 2.8"
screen size. A NEMA 4X enclosure is also available which
can house one or two displays, preassembled at Kele or
separately available for field installation.

SGD-28-M-C-E

FEATURES

APPLICATION

2.4" or 2.8" color TFT screen for high visibility


Free PanelPilot software saves money
Simple USB cable connection for quick setup
6 standard meter types, selectable colors, scales, and
labels for display flexibility
Splash screen accepts common picture files and
allows customization
Snap-in panel mount for fast installation
NEMA 4X enclosure option with single or double
display mounting

SGD-28-M

Temperature
Humidity
Pressure
Air quality
Valve or damper position
Air or water flow
Water level
Light level
Motor speed
Any 4-20 mA or 0-10 VDC transmitter signal

METER CHOICES

Digital

Analog

Analog & Digital

Bar Graph

Bar Graph Meter

Digital & Bar


Graph Meter

SPECIFICATIONS
Supply Voltage
Input Signal
Input Impedance
Wire Type
Accuracy
Display Type
SGD-24

4 to 30 VDC @ 35 mA
0/2-10 VDC, 4-20mA (with resistor)
0-40 VDC max
110 mA @ 5 VDC
Screw terminals, 16 to 26 AWG
0.05% typical, 0.1% maximum

2.4 inch diagonal 320 x 240 pixels,


16-bit color
SGD-28
2.8 inch diagonal 320 x 240 pixels,
16-bit color
Interface
Compatible with Windows XP, 2000,
Vista, Windows 7, mini USB cable
connection
Sample Intervals
3 samples per second
Operating Temperature 32 to 104F (0 to 40C)
Panel Cutout
SGD-24
1.81"H x 2.91"W (4.60 x 7.40 cm) 0.11"

94

888-397-5353 USA

kele.com

SGD-28

(3 mm) maximum panel thickness


2.15"H x 3.43"W (5.45 x 8.70 cm)
0.11" (3 mm) maximum panel thickness

Dimensions
SGD-24

1.9"H x 3.0"W x 0.7"D


(4.8 x 7.6 x 1.8 cm)
SGD-28
2.2"H x 3.5"W x 0.8"D
(5.7 x 8.9 x 1.9 cm)
NEMA 4X enclosure 6.0"H x 6.0"W x 3.0"D
(15.2 x 15.2 x 7.6 cm)
Enclosure Options
NEMA 1 standard NEMA 4X optional
Additional Specifications Meter choices- Bar graph, analog
needle, digital readout, combinations
Approvals
CE, RoHS
Weight
SGD-24
0.11 lb (0.05 kg)
SGD-28
0.14 lb (0.06 kg)
Warranty
1 year

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


PANELPILOT SMART GRAPHICAL DISPLAY
SGD-24, -28

WIRING

*Order Separately

BAS Input
4-20 mA

1 2 3 4

* 250

4-20 mA
Loop-powered
Transmitter

*24 VDC POWER SUPPLY MUST BE


FLOATING (NOT GROUNDED TO
BAS COMMON)

24 VDC
Power Supply

4-20 mA Wiring

++ - +

1 2 3 4

BAS Input
0-10V

+ SIG
+ PWR

0-10 VDC
Transmitter

ALARMS & INDICATION

*Meter must be configured for 1-5 V


input for 4-20 mA input signal, when
using the 250 resistor. If using a 500
resistor, configure the meter for 2-10 V.

1 = IN2 Input 2 (40 VDC max) (not used)


2 = IN1 Input 1 (40 VDC max)
3 = OV Common
4 = v+ Power (4-30 VDC)

1-5 V

++ - +

- +
24 VDC
Power Supply

0-10 VDC Wiring

ORDERING INFORMATION

Note: Custom Calibrated Panels,


require completion of the panel
configuration worksheet. Worksheet available on Kele website
www.kele.com

MODEL
SGD-24-M
SGD-24-M-C
SGD-24-M-C-E
SGD-24-M-C-XK
SGD-24-M-C-XK-E
SGD-24-M-CEDBL
SGD-24-MCXKEDBL
SGD-28-M
SGD-28-M-C
SGD-28-M-C-E
SGD-28-M-C-XK
SGD-28-M-C-XK-E
SGD-28-M-CEDBL
SGD-28-MCXKEDBL

SFP66-258E
SFP66-258F
SFP66-258C
SFP66-258D
USB-A-MF
P6063C-P258
250R-3-1


DCPA-1.2
DCP-1.5-W

March 2014

DESCRIPTION
Smart Graphics Display, 2.4 inch
Smart Graphics Display, 2.4 inch, custom calibrated
Smart Graphics Display, 2.4 inch, calibrated, enclosure
Smart Display, 2.4 inch, calibrated, custom graphic
Smart Display, 2.4 inch, calibrated, custom graphic, enclosure
Smart Display, 2.4 inch, calibrated, enclosure, double
Smart Display, 2.4 inch, calibrated, custom graphic, enclosure, double
Smart Graphics Display, 2.8 inch
Smart Graphics Display, 2.8 inch, custom calibrated
Smart Graphics Display, 2.8 inch, calibrated, enclosure
Smart Display, 2.8 inch, calibrated, custom graphic
Smart Display, 2.8 inch, calibrated, custom graphic, enclosure
Smart Display, 2.8 inch, calibrated, enclosure, double
Smart Display, 2.8 inch, calibrated, custom graphic, enclosure, double

ACCESSORIES
Panel for SGD-24, single
Panel for SGD-24, double
Panel for SGD-28, single
Panel for SGD-28, double
USB Cable Type A TO Mini B
6x6x3 NEMA4X Encl Clear Hinge Cover w/ SOPK Kit
250 OHM 3 WATT 1% Resistor Long Leads
RELATED PRODUCTS
Power supply, 120 VAC IN to 24 VAC/24 VDC OUT
Power supply, 24 VAC IN to 24 VDC OUT

WE MAKE IT EASY.

kele.com

888-397-5353 USA

95

ALARMS & INDICATION


KELE BIG DISPLAY READOUT, 3-1/2 DIGIT LED, RED/BLUE/GREEN
BDR SERIES
DESCRIPTION

The BDR Big Display Readout has large 2.3" size LED digits. It
provides 3-1/2 digits and comes in three bright LED colors: red,
green or blue. The BDR has a selectable decimal point position
and accommodates negative sign readouts. The readouts are in
linear proportion to the 4-20 mA, 0-10 VDC, 0-5VDC signal inputs
or a voltage monitor input from 0-20VDC. These displays are
easy to field calibrate with non-interactive zero and span pots as
well as free pre-calibration service from Kele at time of order.

BDR-G

Large 2.3" (5.8 cm) digital display


LED colors in red, green or blue
3-1/2 digit with negative signal as needed
Standard signal inputs: 4-20 mA, 0-10 VDC, 0-5 VDC
Wall, ceiling or panel mount
Non-interactive zero and span pots
Pre-calibration

BDR-B

BDR-R

SPECIFICATIONS

WIRING
VPI
DCV
LPI
5V
10V
SPAN ZERO SPAN ZERO SPAN SPAN

LPI
OFFSET

VPI

5V

LPI

DP1

VPI

DP2

DCV

SPAN OR ZERO ADJ.


200mV

Calibration pots
(use varies with
source; see
installation
manual)

10V

Display Color
Display Size
Display Type
Range
Calibration
Operating Humidity
Operating Temperature
Cutout Requirement

Dimensions

Enclosure Options
Mounting

Approvals
Weight
Warranty

Mounting Brackets included

2V

Accuracy
Digit Span
Decimal Point

90-240 VAC, 12 VA / 10.5 - 30 VAC/VDC 6VA


4-20 mA, 300
0-5 VDC, 0-10 VDC, 1 M
DC power (no offset, 10 M 0-200 mVDC,
0-2 VDC, 0-20 VDC
1% full scale plus 1 count
3-1/2 digit
Off, DP1, DP2, DP3
(1999, 199.9, 19.99, 1.999)
Red, green, blue
2.3" (5.8 cm)
Seven-segment LED
-1999 to 1999
Zero and span, non-interactive
5-95% RH non-condensing
14 to 122F (-10 to 50C)
4.0"H x 10.4"W x 2.0"D
(10.0 x 26.4 x 5.0 cm)
4.2"H x 10.6"W x 2.2"D
(10.6 x 27.0 x 5.5 cm)
NEMA 1, aluminum and plastic
Panel: Steel U-bracket
Wall/ceiling: Steel swivel bracket
RoHS
2.8 lb (1.3 kg)
1 year

20V

Supply Voltage
Input Current
Input Voltage DC
Input Monitor

DP3

FUNCTION

DECIMAL

DCV

DCV
IN
IN+

LPI = Current signal


VPI = Voltage signal
DCV = Voltage monitor
DP = Decimal point placement
LPI OFFSET = Negative () sign
Choice for V or I
signal
*LPI function disables RANGES
switch

RANGES
200mV

ALARMS & INDICATION

FEATURES

VPI
SIG SIG+

LPI
SIG SIG+

AC POWER
90V-250V
AC
AC

GND

BDR-999-[R/G/B]-24
10.5 to 30 VAC/VDC

INPUT

Power supply monitor


0-(0.2, 2, or 20) VDC
Voltage signal in
0-5 or 0-10 VDC
Current signal in
4-20 mA

ORDERING INFORMATION
Displays are custom calibrated at
no charge and require specification
of input scale (mA, VDC), range,
engineering units, and decimal point
placement.

96

MODEL
BDR-999-R-24
BDR-999-G-24
BDR-999-B-24
BDR-999-R-120
BDR-999-G-120
BDR-999-B-120

DESCRIPTION
Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDC
Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDC
Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 24 VAC/VDC
Red LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VAC
Green LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VAC
Blue LED 3-1/2 digit display, 2.3" (5.8 cm) high 120 VAC


RELATED PRODUCTS
DCPA-1.2
Power supply, 120 VAC IN to 24 VAC/24 VDC OUT
DCP-1.5-W
Power supply, 24 VAC IN to 24 VDC OUT

888-397-5353 USA

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


3-1/2 DIGIT LCD PANEL DISPLAY
LPI-1C

DESCRIPTION

LPI-1C (typical panel mount)

LPI-1C-WMB

ALARMS & INDICATION

Model LPI-1C is a loop-powered indicator featuring a


large 3-1/2 digit LCD display with black digits. The Model
LPI-1C displays engineering units of F, C, PSI, %, or no
engineering units if desired. It is directly powered by the
4-20 mA signal and scaled to specifications.
FEATURES
Indication of 4-20 mA signal in desired scale
3-1/2 digit LCD display
Snap-in panel mounting
Easy-to-read digits
NEMA 4X enclosure available
Precalibrated for desired range
Negative-to-positive indication
Jumper-selectable engineering unit display

APPLICATION




Temperature
Humidity
Pressure
Differential or static pressure
Kilowatt demand

LPI-1C-E



SPECIFICATIONS
Input Signal
4-20 mA loop-powered
Input Impedance
300 nominal @ 24 VDC
Accuracy
0.1% of scale
Digit Size
0.5" (1.27 cm)
Decimal Point
Three positions or none (1.0.0.0)
Display Color
Black
Range
-1999 to 1999
Operating Humidity
95% non-condensing
Operating Temperature 32 to 122F (0 to 50C)
Panel Clearance
1.97" (5.00 cm)
Cutout Requirement
1.00" H x 2.40" W (2.54 x 6.10 cm)
Dimensions
Display
1.11" H x 2.51" W (2.82 x 6.38 cm)
E (NEMA 4X)
6.0"H x 6.0"W x 3.0"D
(15.2 x 15.2 x 7.62 cm)
WMB
2.12''H x 3.12''W x 1.75''D
(5.4 x 7.94 x 4.45 cm)
Approvals
RoHS
Weight
0.14 lb (0.06 kg) (display only)
Warranty
1 year

LPI-1C-E-DBL

Gallons per minute


Voltage
Current
Many other 4-20 mA applications

WIRING
Power
supply
+

Sensor/
transmitter

Connect the LPI-1C


indicator in series with
the 4-20 mA current
loop to be measured.

+
-

4-20 mA

+
S
P
A
N

BAS input
or other
+ 4-20 mA load
-

SIG

Z
E
R
O

Factory calibrated
(no field calibration
needed)

F
C
PSI
%

Engineering unit jumpers


Unit selected displays to
the right of display reading.

Board unit
Connector pins

Back of display unit

ORDERING INFORMATION
MODEL
LPI-1C

DESCRIPTION
3-1/2 digit LCD panel display with black digits*

No enclosure
E
3-1/2 digit LCD panel display with NEMA 4X enclosure
WMB
3-1/2 digit LCD panel display with small enclosure
E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure

LPI-1C

E-DBL Example: LPI-1C-E-DBL Two LPI-1C displays mounted


in a single enclosure

Displays are custom calibrated at no charge


and require specification of input scale (mA),
range, engineering units, and decimal point
placement.


DCP-1.5-W
DCPA-1.2
GP-3420
GP-3430

March 2014

RELATED PRODUCTS
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC In to 24 VAC/24 VDC Out
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm)
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm)

WE MAKE IT EASY.

kele.com

PAGE
93,97-99
93,97-99

888-397-5353 USA

97

NEW!

ALARMS & INDICATION


3-1/2 DIGIT LCD AMBER / GREEN / RED PANEL DISPLAY
LPI-1C-A, LPI-1C-G, LPI-1C-R

ALARMS & INDICATION

DESCRIPTION
Models LPI-1CA, G, and R are 4-20 mA, 24 VDC-powered,
brightly lit 3-1/2 digit color LCD displays, available with
amber, green, or red digits. Models LPI-1CA, G, and R also
feature jumper-selectable built-in engineering units of F, C,
PSI, %, or no units. The same 24 VDC power supply can be
used to provide power to the 4-20 mA loop and the display.
FEATURES
Indication of 4-20 mA signal in desired scale
Bright 3-1/2 digit LCD display
Available in amber, green, and red
Snap-in panel mounting
Easy-to-read digits
NEMA 4X enclosure available
Precalibrated for desired range
Negative-to-positive indication
Jumper selectable engineering unit display
APPLICATION
Temperature
Humidity
Pressure

SPECIFICATIONS
Supply Voltage
24 VDC @ 35 mA
Input Signal
4-20 mA loop powered
Input Impedance
300 nominal @ 24 VDC
Accuracy
0.1% of scale
Digit Size
0.5" (1.27 cm)
Decimal Point
Three positions or none (1.0.0.0)
Display Color
Amber
Display Size
0.5" (1.27 cm)
Range
-1999 to 1999
Operating Humidity
95% non-condensing
Operating Temperature 32 to 122F (0 to 50C)
Panel Clearance
1.97" (5.00 cm)
Cutout Requirement
1.00"H x 2.40"W (2.54 x 6.10 cm)
Dimensions
Display
1.11"H x 2.51"W (2.82 x 6.38 cm)
E (NEMA 4x)
6.0"H x 6.0"W x 3.0"D

(15.2 x 15.2 x 7.62 cm)
WMB
2.12''H x 3.12''W x 1.75''D

(5.4 x 7.94 x 4.45 cm)
DBL
6.0"H x 6.0"W x 3.0"D

(15.2 x 15.2 x 7.62 cm)
Approvals
RoHS
Weight
0.14 lb (0.06 kg) (Display only)
Warranty
1 year

LPI-1C-G
(typical panel mount)

LPI-1C-G-WMB

LPI-1C-R-E
LPI-1C-R-E-DBL
Differential or static pressure
Kilowatt demand
Gallons per minute
Voltage
Current
Many other 4-20 mA applications

WIRING
Power
supply
24 VDC

+ Sensor/
transmitter

Connect the LPI-1C


indicator in series with
the 4-20 mA current
loop to be measured.

- BAS input or
4-20 mA

-+
SIG

S
P
A
N

other 4-20 mA
load

B/L

Z
E
R
O

Factory calibrated
(no field calibration needed)

Board unit
F
C
PSI
%

Connector pins

Engineering unit jumpers


Unit selected displays
to the right of display
reading.

Back of display unit

ORDERING INFORMATION

Displays are custom calibrated at no charge


and require specification of input scale (mA),
range, engineering units, and decimal point
placement.

MODEL
LPI-1C-A
LPI-1C-G
LPI-1C-R

LPI-1C-A


DCP-1.5-W
DCPA-1.2
GP-3420
GP-3430

98

888-397-5353 USA

DESCRIPTION
3-1/2 digit LCD with amber digits*
3-1/2 digit LCD with green digits*
3-1/2 digit LCD with red digits*

No enclosure
E
3-1/2 digit LCD panel display with NEMA 4X enclosure
WMB
3-1/2 digit LCD panel display with small enclosure
E-DBL Two 3-1/2 digit LCD panel displays in one NEMA 4X enclosure
E-DBL Example: LPI-1C-A-E-DBL Two amber 3-1/2 digit
LCD displays mounted in single enclosure

RELATED PRODUCTS
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC In to 24 VAC/24 VDC Out
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm)
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm)

kele.com

PAGE
93,97-99
93,97-99

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION

4-1/2 DIGIT BLACK / AMBER / GREEN / RED DISPLAY


LPI-3C, LPI-3C-A, LPI-3C-G OR LPI-3C-R

DESCRIPTION

Model LPI-3C is a 4-20 mA, brightly lit, 4-1/2 digit display.


Along with standard black digits, amber, green, and red
(powered by 24 VDC) are also available. The Model LPI-3C
also features jumper-selectable built-in engineering units of
F, C, PSI, %, or no units. For those units with colored digits,
the same 24 VDC power supply can be used to provide power
to the 4-20 mA loop and the display.

LPI-3C
(typical panel mount)

LPI-3C-A-WMB

FEATURES

Indication of 4-20 mA signal in desired scale


Optional, bright 4-1/2 digit LCD colored display
Available in black, amber, green, or red digits
Snap-in panel mounting
Easy-to-read digits
NEMA 4X enclosure available
Precalibrated for desired range
Negative-to-positive indication
Jumper-selectable engineering unit display

LPI-3C-G-E

LPI-3C-R-E-DBL

APPLICATION








SPECIFICATIONS
Supply Voltage
24 VDC @ 35 mA for colored digits
Input Signal
Loop-powered 4-20 mA signal
Input Impedance
300 nominal @ 24 VDC
Accuracy
0.1% FS
Digit Size
0.5" (1.27 cm) LCD
Decimal Point
Four positions or none (1.0.0.0.0)
Range
-19999 to +19999
Operating Humidity
95% non-condensing
Operating Temperature 32 to 122F (0 to 50C)
Panel Clearance
1.97" (5.00 cm)
Cutout Requirement
1.00"H x 2.40"W (2.54 x 6.10 cm)
Dimensions
Display
1.11"H x 2.51"W (2.82 x 6.38 cm)
E (NEMA 4X)
6.0"H x 6.0"W x 3.0"D
(15.2 x 15.2 x 7.62 cm)
WMB
2.12''H x 3.12''W x 1.75''D
(5.4 x 7.94 x 4.45 cm)
Approvals
RoHS, Except: (LPI-3CA)
Weight
0.14 lb (0.06 kg) (Display only)
Warranty
1 year

Temperature
Humidity
Pressure
Differential or static pressure
Kilowatt demand
Gallons per minute
Voltage
Current
Many other 4-20 mA applications

ALARMS & INDICATION

WIRING
Power supply
24 VDC
Sensor/
transmitter
4-20
mA

Connect the LPI-3C


indicator in series
with the 4-20 mA
current loop to be
measured.

+ - + SPAN

SIG B/L

BAS input
or other
4-20 mA load
Power connection only required
for amber, green, or red display.
ZERO

Board unit
Factory calibrated
(no field calibration
required)

Connector pins

F
C
PSI
%

Engineering unit jumpers


Unit selected displays to the
right of display reading.

Display unit

ORDERING INFORMATION
Displays are custom calibrated at no charge
and require specification of input scale (mA),
range, engineering units, and decimal point
placement.

MODEL
LPI-3C

LPI-3C


DCP-1.5-W
DCPA-1.2
GP-3420
GP-3430

March 2014

DESCRIPTION
4-1/2 digit LCD panel display*
4-1/2 digit display with black digits
A
4-1/2 digit display with amber digits, (This unit not RoHS compliant)
G
4-1/2 digit display with green digits
R
4-1/2 digit display with red digits

No enclosure
E
4-1/2 digit LCD panel display with NEMA 4X enclosure
WMB
4-1/2 digit LCD panel display with small enclosure
E-DBL Two 4-1/2 digit LCD panel displays in a single NEMA 4X enclosure
A

E-DBL Example: LPI-3C-A-E-DBL Two amber 4-1/2 digit LCD


displays mounted in a single enclosure.

RELATED PRODUCTS
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC In to 24 VAC/24 VDC Out
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 2.00" (8.6 x 5.1 cm)
LPI-1C, LPI-3C, VPI-1C mounting goof plate, 3.40" x 3.00" (8.6 x 7.6 cm)

WE MAKE IT EASY.

kele.com

PAGE
93,97-99
93,97-99

888-397-5353 USA

99

NEW!

ALARMS & INDICATION

KELE 3-1/2 DIGIT LARGE BLACK/RED/GREEN/AMBER PANEL DISPLAY


LPI-4

DESCRIPTION

The Model LPI-4 loop-powered indicator features a large


1" (2.54 cm) 3-1/2 digit display. It is designed to display any
4-20 mA signal in desired scale. The Model LPI-4 is powered
directly from the 4-20 mA signal loop, so there is no need for
a power supply for the black digit model. It is also available in
a 24 VDC powered version with red, green, or amber digits.

LPI-4

ALARMS & INDICATION

FEATURES








Indication of 4-20 mA signal in desired scale


3-1/2 digit LCD display
Large, easy-to-read digits
Available in either black, red, green, or amber digits
Precalibrated for desired range
Snap-in panel mount with retainer
Negative range indicator
Includes weather-resistant seal
Optional jumper-selectable display units F, C, %, PSI

LPI-4G

LPI-4R

APPLICATION
Temperature
Voltage/current
Humidity
Pressure
Killowatt demand
Gallons per minute

LPI-4A

SPECIFICATIONS
Supply Voltage

Black loop powered Red/Green/


Amber 24 VDC @ 35 mA
Input Signal
4-20 mA
Input Impedance
300
Accuracy
0.05% of scale plus one digit
Digit Count
3-1/2 digits
Digit Size
1" (2.54 cm)
Decimal Point
Three positions or none (1.0.0.0)
Range
-1999 to 1999
Operating Humidity
95% non-condensing
Operating Temperature 32 to 122F (0 to 50C)
Cutout Requirement
1.77" x 3.62" (4.5 X 9.2 cm)
Dimensions
1.89"H x 3.78"W x 1.8"D

(4.8 x 9.6 x 4.6 cm)
Approvals
RoHS
Weight
0.25 lb (0.11 kg)
Warranty
1 year

WIRING

Power supply
24 VDC

Power supply
24 VDC

+ Sensor/ +
transmitter

+ +

BAS input
or other
4-20 mA load

Sensor/
transmitter

+ -

BAS input
or other
4-20 mA load

+ - + SIG

SIG

B/L

SPAN

ZERO

LPI-4

SPAN

ZERO

LPI-4R, G, A

ORDERING INFORMATION
MODEL
LPI-4
LPI-4R
LPI-4G
LPI-4A

Displays are custom calibrated at no


charge and require specification of
input scale (mA), range, engineering
units, and decimal point placement.


DCP-1.5-W
DCPA-1.2
GP-5132

100

888-397-5353 USA

DESCRIPTION
3-1/2 digit black panel display
3-1/2 digit red panel display
3-1/2 digit green panel display
3-1/2 digit amber panel display


RELATED PRODUCTS
Power supply, 24 VAC IN to 24 VDC OUT
Power supply, 120 VAC IN to 24 VAC/24 VDC OUT
LPI-4 mounting goof plate, 5.13" x 3.25" (13.0 x 8.3 cm)

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION

KELE 3-1/2 DIGIT SMALL BLACK/RED PANEL DISPLAY


LPI-5

DESCRIPTION

The LPI-5 loop-powered indicator features a small 0.37" (0.94


cm), 3-1/2 digit, black LCD or red LED display. The meter
displays any 4-20 mA signal in desired scale. The Model
LPI-5 is powered directly from the 4-20 mA signal loop, so
the black LCD display and red LED display do not require a
separate power supply.
FEATURES
Indication of 4-20 mA signal in desired scale
Loop powered
3-1/2 digit display
Snap-in panel mounting
Small, easy-to-read display
Precalibrated for desired range
Selectable decimal point location
Positive-to-negative indication (black LCD display)
APPLICATION
GPM
Kilowatt demand
Voltage/Current

LPI-5R

SPECIFICATIONS
Supply Voltage
Input Signal
Input Impedance
Black
Red
Accuracy
Digit Count
Digit Size
Decimal Point
Display Color
Engineering Units
Range
Black

24 VDC @ 35 mA
4-20 mA
300
380
0.1% of scale plus one digit
3-1/2 digits max
0.37" (0.94 cm)
Three positions of none (1.0.0.0)
Black, Red
(Black only) M, k, C, m, V, F, A,
-1999 to 1999, min span 100 digit
counts

Red
0 to 1999
Operating Humidity
95% RH non-condensing
Operating Temperature 32 to 130F (0 to 54C)
Cutout Requirement
Black
0.86"H x 1.57"W (2.2 x 4.0 cm)
Red
0.8"H x 1.3"W (2.0 x 3.3 cm)
Dimensions
Black
0.95"H x 1.73"W x 1.1"D

(2.4 x 4.4 x 2.8 cm)
Red
1.28"H x 1.82"W x 1.6"D

(3.25 x 4.64 x 4.0 cm)
Approvals
RoHS
Weight
0.13 lb (0.06 Kg)
Warranty
1 year

ALARMS & INDICATION

Temperature
Humidity
Pressure

2
LPI-5

WIRING
24 VDC Power supply

+ -

+
Sensor/
transmitter -

- BAS input
or other
+ 4-20 mA load

4-20 mA

Factory calibrated
(No field calibration needed)

SIG

LPI-5
or
LPI-5R

ORDERING INFORMATION
Displays are custom calibrated at no
charge and require specification of
input scale (mA), range, engineering
units, and decimal point placement.

MODEL
LPI-5
LPI-5R

DCPA-1.2
DCP-1.5-W

March 2014

DESCRIPTION
3-1/2 digit small black LCD panel display
3-1/2 digit small red LED panel display

RELATED PRODUCTS
Power supply, 120 VAC IN to 24 VAC/24 VDC OUT
Power supply, 24 VAC IN to 24 VDC OUT

WE MAKE IT EASY.

kele.com

888-397-5353 USA

101

ALARMS & INDICATION


PULSE OR RUN-TIME ACCUMULATOR DISPLAY
ALD-1
DESCRIPTION

The ALD-1 is a 5-1/2 digit LCD resettable accumulator or runtime counter. The lithium battery provides years of troublefree service. Two wires are all that are necessary to totalize
consumption, flow data, or run-time data. No external power
supply is necessary.

GROUND
SHIPPING
ONLY

ALARMS & INDICATION

FEATURES
Resettable accumulator or run-time counter
Long life lithium battery
No external power supply

WIRING
Switch
Contact
Count

(orange) (not used)

N.O.

Run
ALD-1C/10C
Run Time
Clock

(+) (white)

ALD-1/R
Accumulator
Counter

(+) (blue)
(-) (orange/white)

Reset

(+) Cnt (white)


Rst (blue)
Switch
Contact

(-) Com (black)

ALD-1R
Reset Wiring

N.O.

Reset

SPECIFICATIONS
Battery Life
Input
Count Speed
Accumulator
Timer counts
Digit Size
Display
Range

10 years nominal
Contact or solid-state switch
100 counts per second
One-hour or 0.1-hour increments
0.2" (0.51 cm) high
5-1/2 digit
0-199999

Reset
Push button or remote contact
Operating Temperature 32 to 122F (0 to 50C)
Panel Cutout
1.0"H x 2.0"W (2.54 x 5.08 cm)
Bezel
1.1"H x 2.09"W x 1.72"D
(2.79 x 5.3 x 4.37 cm)
Weight
0.13 lb (0.06 Kg)
Warranty
2 years

ORDERING INFORMATION
MODEL
ALD-1
ALD-10C
ALD-1C
ALD-1R

102

888-397-5353 USA

DESCRIPTION
LCD push-button resettable accumulator counter
LCD run-time remote reset clock, one-hour increments
LCD run-time remote reset clock, 0.1-hour increments
LCD remote reset accumulator counter

kele.com

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March
March
20142014

NEW!

ALARMS & INDICATION


EDWARDS AUDIBLE AND VISUAL SIGNALS
SIGNALING BASICS

VISUAL SIGNALING BASICS BY EDWARDS SIGNALING


From the amber light of a rotating beacon at an airport to the double flash of a red strobe in a Division 2 area, Edwards provides
the widest array of visual signaling solutions in the industry. The following is a brief overview of some of the types of visual
signals and applications.

BEACON TYPES AND THEIR APPLICATIONS


Rotating Beacons

LIGHT SOURCES AND THEIR


APPLICATIONS
Edwards signals use a variety of light sources: halogen,
standard incandescent, LED, and strobe. The following is a
brief overview of these type of light sources and their use.

Flashing Beacons

LED

Used to signal attention and equipment condition in process


control lines, airport baggage areas, and other areas
requiring human interface.

Use in areas where vibration resistance and long life are of


utmost concern. Light output with older technology LEDs is
relatively poor; newer technology LEDs have vastly
improved light output but are still expensive.

Double Flashing Beacons


Used to signal attention and equipment condition over wide
areas. Sometimes used in lieu of Rotating Beacons.

Halogen

Used to identify a continuous source or process.

Use in areas where high light output and long life are
considerations. Halogen light sources work well in high
ambient light areas. However, halogen bulbs tend to perform
unfavorably in high vibration environments.

Strobe Lights

Incandescent

Used for equipment status and malfunction indication over


large and high noise areas.

Incandescent light sources are typically the most


inexpensive. They are often used in applications where cost
is a driving factor. Incandescent bulbs tend to have a
relatively short life span. Their light output, while usually
sufficient, is less than that of a halogen or strobe.

Steady Beacons

Diode Supervised and UL 1971 Strobe Lights


Diode polarized strobes are used in electronically
supervised alarm circuits. When the strobe has a UL 1971
listing it may also be used in compatible fire alarm systems
as a signaling device for the hearing impaired.

LENS COLORS AND THEIR APPLICATIONS


Most Edwards strobes, steady and flashing beacons come in
six lens colors: amber, blue, clear, green, magenta and red.
Edwards LED signals come in amber, blue, green, red and,
in some cases, white. The following are examples of how
various lens colors are used in industrial and commercial
signaling environments:
Amber
Denotes caution.
Blue
Used for safety and security.

Strobes
Strobes are known for their exceptional bright burst of light
energy. A strobe light passes a brief, intense pulse of electric
current through a gas, which then emits a brilliant burst of
light. The gas is usually one of two inert gases, xenon or
krypton. Strobe lights are very vibration resistant and will
function for thousands of hours before requiring
replacement.

CAT. NUMBER VOLTAGE SUFFIXES


Edwards visual signals are available in a wide variety of
voltages. Each signal has a catalog number suffix which
indicates the voltage of that specific signal. The following is a
list of the cat. number suffixes and the voltages they
represent:

Clear (or White) & Green

Suffix

Voltage

Suffix

Voltage

Used to indicate normal run operation.

-AQ

24V AC/DC

-G5

24V AC 50/60 Hz

Magenta

-E1

12V DC

-GW

24-28V DC

Used for radiation alarms.

-EK

12-48V DC

-MP

72-125V DC

Red

-FJ

20-30V DC

-N5

120V AC 50/60 Hz

Denotes emergency or warning.

-FY

36V DC

-R5

240V AV 50/60 Hz

24V DC

-S1

250V DC

-G1

March 2014

ALARMS & INDICATION

Used to signal over a large area such as in airports,


distribution centers and large process areas.

WE MAKE IT EASY.

kele.com

888-397-5353 USA

103

ALARMS & INDICATION


EDWARDS AUDIBLE AND VISUAL SIGNALS
SIGNALING BASICS
AUDIBLE SIGNALING BASICS BY EDWARDS SIGNALING
From the soft melodic sound of a chime, to the ear piercing emergency blast of an outdoor warning signal, Edwards audible
signals produce sounds that demand immediate attention.

AUDIBLE SIGNALS AND THEIR APPLICATIONS


Vibrating and Single Stroke Bells

ALARMS & INDICATION

6", 8", and 10" bells are used for alarms over large areas
such as distribution centers. 4" bells are used for smaller
applications. Single stroke bells are most useful for paging
applications.
Vibrating Horns
Used to signal attention and equipment condition in process
control lines and other areas requiring human interface.

2. Uniform Sound Distribution


Usually, better signal distribution can be achieved by carefully
positioning a number of smaller signals throughout a given
area than by centrally locating a single large unit.
3. Ambient Sound Conditions

Buzzers
Most often used for local annunciation of noncritical events
but can also be used when a distinctive paging signal is
required.
Chimes
Suitable for relatively quiet locations to page or locally
annunciate.
Sirens and Outdoor Warning Signals
For use in general services and emergency warning over
large geographic areas.
Multiple Tone Signals
Used in stand-alone and signaling systems that require
multiple tone selectability and flexibility.
Voice Signals
Used where the delivery of specific instructions are required.

SOUND PRESSURE LEVELS


Sound pressure fluctuations diminish or die out with increasing
distance from the sound source. A distance must generally be
specified along with the dB rating to fully describe a sound. The
sound pressure level changes 6 dB for each halving or doubling
of distance. For a change in distance of ten times, the sound
pressure level changes 20 dB.

TYPICAL DB LEVELS WHEN SELECTING


AUDIBLE SIGNALS
In specifying a signaling device, the above characteristics
should be considered along with as many factors concerning
the application as can be gathered. Selecting the proper device for
each signaling application need not be difficult if the
following points are observed.
1. Signal Function
Basically, the types of functions to which signals can be applied
are: general alarm or emergency, start and dismissal,
paging or coding, localized danger, and indication.
The first step in selecting a signal is to carefully define this
function. Is the signal to be a warning, a call, or an instruction?
Will it be used to protect life or property? How much
time will be available to take action?

104

Obviously, the more critical the application, the more startling


the signal generated must be. A horn is generally the most
startling signal. Its rasping tone commands immediate attention.
A single stroke bell can be used for paging applications
where danger is not at hand. A small buzzer may serve to
notify a machine operator that a particular operation is completed.

888-397-5353 USA

kele.com

The frequency of the signaling device selected should be as


different from the background noise as possible. The signal
should override this noise by a minimum of six decibels. Usually,
the noisier the area, the louder the signal required and
the greater the number required.
4. Size of Area to be Covered
The larger the area, the louder the signal required or the
greater the number of units required. Better coverage is
frequentlyobtained by the use of several signals of lower dB
rating than by the use of one very loud signal, providing the
signals can be positioned to advantage.

5. Mounting Considerations
The surface that the signal is mounted on can markedly affect
the signals performance. A horn, for example, should be rigidly
mounted to a sturdy surface so that all of its energy is directed into
the sound output and not absorbed by the wall. A
buzzer, however, can sound much louder if mounted on a
resonant surface because it will act as a sound board for the
device.

CAT. NUMBER VOLTAGE SUFFIXES


Edwards audible signals are available in a wide variety of
voltages. Each signal has a catalog number suffix which
indicates the voltage of that specific signal. The following is a
list of the cat. number suffixes and the voltages they
represent:

Suffix

Voltage

Suffix

Voltage

-AQ

24V AC/DC

-G5

24V AC 50/60 Hz

-E1

12V DC

-GW

24-28V DC

-EK

12-48V DC

-MP

72-125V DC

-FJ

20-30V DC

-N5

120V AC 50/60 Hz

-FY

36V DC

-R5

240V AV 50/60 Hz

-G1

24V DC

-S1

250V DC

WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.

March 2014