Inputs 1 to 8
Outputs 1 to 6
SW1
address.
Set DIP switch 8 on S101 to ON if the Aperio hub is
INPUT 1
INPUT 8
SW2
OUTPUT 7
JW4
NO NC
OUTPUT 1
OUTPUT 2
JW6
DIP
D0
RED
ON
GREEN
1 2 3 4 5 6 7 8 9 10
INT
Aperio
USB connection
Hub 1
TERM
UP
DOWN
A4
A3
A2
A1
A0
OUTPUT 6
Outputs 7 and 8
Outputs 7 and 8 are programmable and provide:
P6 - P5 +OFF
BAT-
INPUT
BAT+
JW1 OPEN
JW2 OPEN
- S +
SW2
Aperio
Hub 3
Ribbon cable
connects to P3
on main board
ON
ON/OFF
A BSwitch
SW1
SW2 sets the Card Access controller RS-485 network address and
determines how the IP module get its IP address (if installed).
Connection for
front door LEDs
Address 1
Red
12 V BATTERY
Jumpers
MD-1113 Module
Aperio
Hub 1
A B
JW1 OPEN
JW2 OPEN
S101
DIP 6 OFF
DIP 7 OFF
DIP 8 OFF
Aperio
Hub 2
Aperio
Hub 3
A B
A B
S101
DIP 6 OFF
DIP 7 OFF
DIP 8 OFF
S101
DIP 6 ON
DIP 7 ON
DIP 8 ON
A B
A B
A B
S101
DIP 6 ON
DIP 7 ON
DIP 8 ON
S101
DIP 6 OFF
DIP 7 OFF
DIP 8 OFF
S101
DIP 6 OFF
DIP 7 OFF
DIP 8 ON
JW1 OPEN
JW2 OPEN
Aperio
Hub 2
OFF
16 Guage
Wire
MD-1113 Module
RS-485
ON
software.
Address 4
Address 3
Ground
Terminal
optional
Address 2
S101
DIP 6 OFF
DIP 7 OFF 1
8
1
8
1
8
1
DIP 8 ON
Keep DIP switch 7 at the factory set value
S +
Connections
S101
DIP 6 OFF
DIP 7 OFF
DIP 8 OFF
OUTPUT
Black
J100
12 Vdc
P7
Aperio
Hub 2
P1
RS-485
Thermal Kit
8-24VDC
NO
MD-1113
S101
OUTPUT 5
ALARM
JW 1
S101
DIP 6 ON
DIP 7 ON
DIP 8 ON
EXT
30 Vdc \ 3 amp
NO NC
TROUBLE
Connection to 12V
battery
backup Module
MD-1113
A B
ANTENNA
OUTPUT 4
LEDs
JW 5
NO NC
OUTPUT 3
P4
NO NC
AC
JW2
Outputs 7 and 8
IP Module Interface
NO NC
O u ttpu
p u t s 1 to 6
JW3
GND
OUTPUT 8
Inputs 1 to 8
D1
NC
12V
12V
Ground Terminal
The Card Access system is equipped with a 16 gauge electrical
wire attached to the panel chassis Ground Terminal. Do not
disconnect this wire.
Attach the end of the supplied wire to a suitable grounding wire
16 gauge or thicker. Attach the other end to the cold water
ground.
for more information see LT-1160 Aperio Door Controller System Manual
available on CD, USB flash drive, or website WWW.MIRCOM.COM
Aperio Hub 1
Aperio Hub n
Installation Prerequisites
OUTPUTS 1 to 6
INPUTS 1 to 8
General
purpose input
1 pair
22 AWG
General
purpose input
1 pair
22 AWG
1 pair
22 AWG
Ensure there is a provision for a ground circuit. The Aperio Door Controller assembly must be grounded by a qualified
electrician. An improperly grounded unit can result in equipment malfunction and void the warranty.
Use the latest Aperio Door Controller System controller firmware. Mircom periodically updates panel firmware and
Configurator Software to add features and correct any minor inconsistencies. For information about the latest firmware
or software visit the Manuals and Downloads section of the Mircom website at www.mircom.com.
Aperio Door
Controller
Basic Wiring
3 wires
22 AWG
1 pair
18 AWG
1 pair
22 AWG
General
purpose input
General
purpose input
OUTPUTS 7 to 8
22 AWG
Programmable outputs
Combined 1 amp output
12 Vdc
500 mA
Power
transformer
16VAC/40VA
PS-4 or PS-4P
Power
transformer
AC or DC Door
strike supply
Configure the system using the Configurator software using a USB or modem connection. Verify the following:
Ensure that the controller and all connected devices and components are fully operational.
Ensure the Configurator software is set with the correct controller RS-485 network address.
120 VAC
60HZ
Wiring requirements
Install all transformers outside the Lobby Control Unit enclosure.
Unless specified otherwise, all wiring is a maximum length of 1000 ft. The RS-485 wiring maximum length is 4000 ft.
All units use the PS-4P transformer for the power supply. The door strike power supply depends on the door strike
Version 0.11
LT-1164
Ensure the controller DIP Switches are set with a unique RS-485 network address.
power requirements.
RS-485 Network
for TX3 devices
Electrical room
Ensure that your PC is set with the correct date and time.