241
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
Alarmas GFP
1. Select the
Transmission
domain and then a
GFP remote port
3. Select Alarms
2. Choose Configure
Ethernet Port
242
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
78
NE B
SDH
1002
1001
SDH
Eth
77
NE A
Eth
TSF
TSF
Posible simulacin
1. Desconectar las conexiones fsicas SDH.
2. Borrar las DXC SDH entre los puertos remotos
VC y el punto de Terminacin SDH.
243
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
port #1002
66
NE B
SDH
1002
1001
SDH
Eth
65
NE A
Eth
Posible simulacin:
Configure port #1001 como ETH on Laps y
port #1002 como ETH on GFP
244
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
port #1001
1 Alarms
Configuracin GFP
Select GFP
245
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
Configuracin GFP
Send Control: asignar el cdigo de Signal Label (SL insertado dentro de la
trama GFP).
Opciones posibles de pulldown:
automatic/forced:
Automtica significa que tx SL ser automaticamente calculada
Forced signfica que tx SL ser siempre forzado a un cdigo no
especificado).
246
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
La alarma CSF (Client Signal Fail) se inserta por los puertos remotos
en dos casos:
Falla en el Puerto Local: CSF se inserta, thacia la red SDH, dentro de la
trama GFP, en el caso de deteccin de LOS sobre el puerto Ethernet Local.
NE B
78
1001
SDH
Eth
77
LOS
CSF
detection
SDH
1002
CSF
NE A insertion
Eth
Falla sobre el puerto Remoto: CSF se inserta, hacia la red SDH, dentro de la
trama GFP, en caso de una o mas de las siguientes alarmas: LOF, TSF, PLM.
TSF
247
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
NE B
78
CSF
detection
SDH
1002
1001
SDH
Eth
77
NE A
CSF
insertion
Eth
1 Alarms
248
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
Seleccione Mau
para un puerto
local
249
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
NE B
78
SDH
1002
CSF
detection
1001
SDH
Eth
77
CSF
NE A insertion
Interface
shutdown
Eth
Link
down
Port#78 shutdown
es disparado por la
alarma CSF sobre el
port #1002.
As el link entre
port #78 y el
dispositivo Ethernet
adjuntado est
down.
1 Alarms
Hub-Spoke configuration
Downstream
Upstream
2 4 10
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
NE C:
It requires Hub-Spoke configuration
79
1002
SDH
SDH
SDH
SDH
1003
1004
NE A and NE B:
in this example they need no Hub-Spoke
configuration
NE A
80
NE B
81
Port-To-Port
Host 1
Host 2
2 4 11
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
2. Configure
Hub-Spoke
1 Alarms
TSF
NE B
78
77
Eth
1001
SDH
NE A
SDH
1002
Desconecte
el cable
LOS
Eth
POM
Before
Matrix
2 4 13
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
VC-AIS
1 Alarms
2 4 14
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
LOPC
DEG
VC3
#1
VC3
#2
Outer
Tail
Tunnel
ETS XC
TU3
#1
TU3
#1
PPP port
MPLS port
SDH XC
SDH port
C
SDH port
D
Outer
Head
Tunnel
TU3
#1
TU3
#1
SDH port
A
Inner
Head
Tunnel
VC3
#1
VC3
#2
SDH port
B
OUT
FLOW
MPLS port
PPP port
ETS XC
CLASSI
FIER
IN
FLOW
SDH XC
Disconnect
the cable
IN
FLOW
Inner
Tail
Tunnel
OUT
FLOW
1 Alarms
2 4 15
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
1 Alarms
Alarm surveillance
2 4 16
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation
End of Module
Alarm Management
2 4 17
NE Operation Alarm Management
ALU ISA ES16 ALU ISA ES16 Ethernet + MPLS features rel. 2.5 Operation