Anda di halaman 1dari 9

PROJECT :

LOCATION :
SUBJECT :
DATE
:
ITEM NO.
1

Page

OSSAIMI APPARTMENTS AND BEACH RESORT


JUMEIRAH, DUBAI, UAE
GRC COLUMN FIXING CALCULATION - rev 11
27-07-2015
GRC COLUMN - ELEVATION - SECTION

SS 10 mm threaded rod
Tributary area

Tributary area

Page

Design for the bolt fixing support for the grc crown
detail

SS 10 mm rod

steel bracket 50x50x6mm

Compute for the Weight of GRC


Given :
GRC Unit Wt. =
For Steel :
E=
Steel Unit Wt. =

2000 Kg/M

200000 MPa
7850 Kg/M

Compute for the section area of the crown:


As =
Vol =

Page

73880 mm
diam =
0.07388 M
As ( )
0.07388(3.141592654 x 2.4)
0.557 M

2400 mm

For threaded rod:


Wt .2 = 1/2 Wt.1
Vol =
wt.2 =
2732.5 N
Check for Shear on bolt
Compute for GRC Wt.
fv =
Wt.2
As
Wt.1 = Unit Wt. x Vol
2732.5
Wt.1 = 2000 ( 0.557 )
78.54
1114.084 Kg x 9.81
fv =
34.79 N/mm
10929.17 N ( divided by 2) as per tributary area
Wt.1 = 5464.583
say Wt.1 =
5465 N
Allow. Fv = 0.4Fy = 0.4(250)
Allow. Fv =
100 N/mm
OK
3

5465 N
Check for the strength of the
Steel Bracket
724 mm
630 mm

section of
50 x 50 x 6mm angle

Section Area (50 x 50 x 6)


Atot =
564
mm
A1 =
300
mm
A2 =
264
mm
A1

178
555

84

y1 = 3
y2 = 28

y2
Compute for the Moment
M = GRC Wt. ( 84 )
M = 5465 (84)
M=
459060 N-mm

A2
by area moment method, s =
Atot (s) = A1 y1 + A2 y2
564 s = 300( 3 ) + 264( 28 )
s=
8292
564
s=
14.70

Check for the Bending


fb = M c
I
fb =
fb =

but c = 50 - s
c = 35.30

I = bh + A a
12
but a1 =

459060 x 35.3
137624
117.74 N/mm

s - y1
11.70
a2 = y2 - s
13.30
I1 = (50)(6) + 300(11.7)
12
4
41981.94 mm
I2 = (6)(44) + 264(13.3)
12

Allow. Fb = 0.66 Fy since Fy < 65 Ksi


allow. Fb = 0.66(250) =

165 N/mm

Check for Deflection

95642.02 mm
def =

Pa(3 L - a)

a = 84

6EI
a = 7056
def =
(5465)(7056)(3(178)-84)
6(200000) 137624

def =

1.74E+10
1.65E+11
0.105 mm

Allow. Def = L/240 = 178(240) =

I = I1 + I2=

4
137624 mm

OK
0.742 mm
trib. Area = 563884 mm

Page

5465 N

X
at joint b

5465 N
fba
b

fdb
Sum of forces along Y-axis = 0 = fdb(250/555) - 5465
fdb = 5465(555)
250
12132.3 N (compression)
Sum of forces along X axis = 0 = 12132.3(546/555) - fba
fba = 11935.56 N ( tension)
For compression, check for the slenderness of member fdb
KL/r =
Compute for r:
r=
r=
r=
KL/r =
Check for Cc
Cc =

where K = 1
L=
I
A
137624
564
15.62
35.53

2(E)
Fy
Cc = 2(200000)
250
Cc =
125.66

Note :
Page

see Mungo Fixing Design Calc


for the anchor bolts
5

555

mm

since KL/r < Cc use the allow. Fa


1 - 0.5(KL/r) x Fy
Fa =
Cc
5 + 3(KL/r) - 1(KL/r)
3 8(Cc)
8(Cc)
Fa =

Fa =
fa =
fa =

240.01
1.770

(KL/r)/Cc= 0.282732

(KL/r)/Cc= 0.079938
135.61 N/mm (allowable)
(KL/r)/Cc= 0.022601
P
A
5465
fa =
9.69 N/mm
564
OK, less than allow.

At the Crown

SS threaded rod 10mm diam.

Check for the Wind Load


Wp =

1.3 Kpa

Fw = Wp ( Ta )
Ta =

563884 mm
0.563884 M

Fw = 1.3(0.563884)
0.73305 KN
Fw =
733.05 N
Say Fw =

735 N

For Shear
fv =

A area of sect. =
78.54 mm
P
sum of forces along x-axis
A
Fx = 0 = Fw - 3r
245
r=
Fw
78.54
3
fv =
3.12 N/mm
735
OK, less than allowable
3
r=
245 N
the reaction is
small
Allow. Fv = 0.4 Fy = 0.4(250) = 100 N/mm
At the column
Wp =

2.09 Kpa

Fw = Wp ( Ta )
Ta =

1124680 mm
1.12468 M

Fw = 2.09(1.12468)
2.35058 KN
Fw = 2350.58 N
Say Fw =
2350 N
1100
Solve for r:
Sum of forces along y = 2r - Fw = 0
2r =
2350 N
r=
1175 N
less than 10KN, it is safe
1.175 KN
Page

For the GRC Column

Tributary Area

2995

1515

Tributary height =
Diameter =
Average thickness=
Area =

2995 mm
1100 mm
30 mm

Arch length x height


851 x 2995
2548745 mm

Compute for the Volume


Vol = Area x ave thick
Vol = (2548745 x 30 )
Vol = 76462350 mm
0.076462 M
Compute for the Wt.
Wt. = Unit wt x Volume
Wt. = 2000 x 0.076462
152.92 Kg x 9.81
1500.191 N
say Wt. =
1500 N
r = Wt./2
r = 1500 /2 =
750 N
Page

Check for Shear on the bolt SS 10mm :


fv = r/A =
750
78.54
fv =
9.55 N/mm OK, less than allow.
Allow. Fv = 0.4Fy = 0.4(250) = 100 N/mm

Tributary height =
Diameter =
Average thickness=
Area =

2950
1100
30

Arch length x height


743 x 2950
2191850 mm

Compute for the Volume


Vol = Area x ave thick
Vol = (2191850 x 30 )
Vol = 65755500 mm
0.065756 M
Compute for the Wt.
Wt. = Unit wt x Volume
Wt. = 2000 x 0.065756
131.51 Kg x 9.81
1290.123 N
say Wt. =
r = Wt./2
r = 1290 /2 =

1290 N

645 N

The design of 10 mm rod is OK

Page

Check for Shear on the bolt SS 10mm :


fv = r/A =
645
78.54
fv =
8.21 N/mm OK, less than allow.
Allow. Fv = 0.4Fy = 0.4(250) = 100 N/mm

30 mm
average thickness

compute for the centroid of the section


A1 =
A2 =
A3 =
A4 =
A5 =
A6 =
A7 =

839(30)
100(30)
350(30)
70(30)
396(30)
432(30)
545(30)

25170
3000
10500
2100
11880
12960
16350
81960

x1 =
x2 =
x3 =
x4 =
x5 =
x6 =
x7 =

419.5
824
1014
1174
1031
678
272.5

Solve for the centroid of the section or dist x


by Area moment method:
81960 x =

25170(419.5) + 3000(824) + 10500(1014) + 2100(1174) + 11880(1031)+


12960(678) + 16350(272.5)
x=
629.99

Page

Anda mungkin juga menyukai