Anda di halaman 1dari 4

How to Improve Swap DCR Background:

in swap project,after swap there were some cells with worse dcr,in order to improve
this kpi,We summarized these aspects and gave some suggestions:
1. Hardware Problem.
1.1 check the alarm and history alarm,normally it can lead to call drops due to
Equipment Failure.
1.2 reset the site,If there are some call drops due to Equipment Failure without
alarm,maybe there are something wrong with our BTS software.reset the site with
level 4 during night.if also not ok,get the help from BSC guy.
1.3 check the WSWR of the site through MML,if the value of VSWR is bigger than
1.5,maybe there are something wrong with feeder,TMA,or antenna and so on.let site
enginner go to this site with site master for testing the VSWR. 2014-6-18
1 , 6
2. CELL CONFIGURATION
2.1 Power configuration,For our swap project,we should keep the same power with
before.Our trx default power as below,we can adjust the power type,power level and
power finetune of trx to keep the same with alcatels TOC. TRX TYPE Static TOC
GRFU 1TRX 80w/49dBm GRFU 2TRX 40w/46dBm GRFU 3TRX 27w/44.3dBm GRFU
4TRX 20w/43dBm GRFU 5TRX 12w/40.8dBm GRFU 6TRX 10w/40dBm DRFU 900
45W/46.5dBm DRFU(PBT) 1800 63w/48dBm 2014-6-18
2 , 6
3. DRFU 1800 40W/46dBm 2.2 Send Receive Mode checking,for different trx
configuration,there are different values of send receive mode.according to the
configuration as below,pls correct it. TRX CONFIGURATION Send Receive Mode 1
GRFU Double Feeder(1TX+2RX) 2 GRFU Single Feeder(1TX+2RX) 1 DRFU Double
Feeder(2TX+2RX) 2 DRFU (PBT) Single Feeder(1TX+2RX) 2.3 Neighbors
Relationship,we can use Nastar to check the neighbors,especially missing
neighbors. 2014-6-18 3 , 6
4. 2.4 Frequency HSN MAIO and so on.
5. 3 DATA CONFIGURATION 3.1 Coverage Parameters About this kind problem,firstly
we can collect the Measurement from M2000: Number of MRs based on TA per TRX
Radio Link Failure Measurement per TRX Radio Link Failure Measurement based on
TA per TRX Receive Quality Measurement per TRX TCHF Receive Level Measurement
per TRX TCHH Receive Level Measurement per TRX Uplink-and-Downlink Balance
Measurement per TRX After we anlyzed the report,we can know about the Receive
Quality,Level,TA and so on.if the TA is big for coverage plan,we should control the

coverage.parameters we can adjust as below: a. RACH Min.Access


Level(dbm),default value is -115,recommended value -109. b. Random Access Error
Threshold, default value is 180, recommended value 220 c. RXLEV_ACCESS_MIN,
default value is 8, recommended value 10. d. otherwise,we can adjust downtilt and
power to control the coverage. 3.2 Interference Parameters About this kind of
problem,we can collect the Measurement from M2000: Radio Link Failure
Measurement per TRX Receive Quality Measurement per TRX TCHF Receive Level
Measurement per TRX TCHH Receive Level Measurement per TRX GSM Cell to GSM
Cell Outgoing Handover Measurement Interference Band Measurement per TRX
After anlysis,if there are high receive level with bad quality,a lot of quality
handovers and interference band are bigger than 3,there maybe interference,we
can adjusted the parameters as below: a. Radio Link Timeout(SACCH period
(480ms)) this parameter is about downlink, default value is 16, recommended value
52 b. SACCH Multi-Frames(SACCH period (480ms)) this parameter is about uplink,
default value is 18, recommended value 36. c. T200 FACCH/F(5ms) default value is
50,recommended value 80. d. T200 FACCH/H(5ms) default value is
50,recommended value 80. e. N200 of FACCH/Half rate, default value is
29,recommended value 50. f. N200 of FACCH/Full rate, default value is
34,recommended value 50. g. if there is strong interference through monitoring
channel interference band,we need 2014-6-18 5 ,
6
6. eliminate it. 3.3 Handover Parameters About this kind of
problem,we can collect the Measurement from M2000: Incoming Internal Inter-Cell
Handover Measurement per Cell Outgoing Internal Inter-Cell Handover Measurement
per Cell Incoming External Inter-Cell Handover Measurement per Cell Outgoing
External Inter-Cell Handover Measurement per Cell GSM Cell to GSM Cell Outgoing
Handover Measurement After anlysis,if there is bad hsr between 2 neighbors,and
also Cell Outgoing Handover Fail Reconn Fail happens,we need adjust some
handover parameters as below: a. Edge HO UL RX_LEV Threshold,default value is
10,recommended value 15. b. Edge HO DL RX_LEV Threshold,default value is
19,recommended value 25. c. Min DL Power on HO Candidate Cell,default value is
10,recommended value 0. d. Min UP Power on HO Candidate Cell,default value is
10,recommended value 0. e. Min Interval for Consecutive HOs,default value is
4,recommended value 2. f. Min Interval for Emerg.HOs,default value is
4,recommended value 2. g. Filter Length for TCH Level,default value is
6,recommended value 3. h. Filter Length for TCH Qual,default value is
6,recommended value 3. i. DL Qual. Threshold,default value is 55,recommended
value 40. j. UL Qual. Threshold,default value is 55,recommended value 40. k.
MR.Preprocessing, default value is YES,recommended value NO. About the values of
parameters,just recommended,you can decide to choose according to actual
situation, detailed meaning of these parameters,you can get it from LMT help
document,thanks, 2014-6-18 6 , 6

7. eliminate it. 3.3 Handover Parameters About this kind of


problem,we can collect the Measurement from M2000: Incoming Internal Inter-Cell
Handover Measurement per Cell Outgoing Internal Inter-Cell Handover Measurement
per Cell Incoming External Inter-Cell Handover Measurement per Cell Outgoing
External Inter-Cell Handover Measurement per Cell GSM Cell to GSM Cell Outgoing
Handover Measurement After anlysis,if there is bad hsr between 2 neighbors,and
also Cell Outgoing Handover Fail Reconn Fail happens,we need adjust some
handover parameters as below: a. Edge HO UL RX_LEV Threshold,default value is
10,recommended value 15. b. Edge HO DL RX_LEV Threshold,default value is
19,recommended value 25. c. Min DL Power on HO Candidate Cell,default value is
10,recommended value 0. d. Min UP Power on HO Candidate Cell,default value is
10,recommended value 0. e. Min Interval for Consecutive HOs,default value is
4,recommended value 2. f. Min Interval for Emerg.HOs,default value is
4,recommended value 2. g. Filter Length for TCH Level,default value is
6,recommended value 3. h. Filter Length for TCH Qual,default value is
6,recommended value 3. i. DL Qual. Threshold,default value is 55,recommended
value 40. j. UL Qual. Threshold,default value is 55,recommended value 40. k.
MR.Preprocessing, default value is YES,recommended value NO. About the values of
parameters,just recommended,you can decide to choose according to actual
situation, detailed meaning of these parameters,you can get it from LMT help
document,thanks, 2014-6-18 6 , 6

Brief for CV:


Issue
Hardware

Cell Configuration

Handover Parameters:

Solution
Check Alarms if Call Drops due to equipment failure then, reset the site.
If no alarm on site, there are still call drops, then reset the site with Level 4,
might be something wrong with BTS software.
Check for VSWR if value is greater than 1.5,there might be something
wrong with feeder,TMA,or antenna and so on, BSS team with site master
will check the site.
Power Configuration: Huawei Default Configuration is as: GRFU 1TRX
80w/49dBm,GRFU 2TRX 40w/46dBm,GRFU 3TRX 27w/44.3dBm,GRFU 4TRX
20w/43dBm,GRFU 5TRX 12w/40.8dBm,GRFU 6TRX 10w/40dBm,DRFU 900
45W/46.5dBm DRFU(PBT) 1800 63w/48dBm.
DRFU 1800 40W/46dBm.
Send Receive Mode checking, for different TRX configuration, there are
different values of send receive mode. According to the configuration as
below, please correct it. TRX CONFIGURATION Send Receive Mode:
1 GRFU Double Feeder(1TX+2RX)
2 GRFU Single Feeder(1TX+2RX)
1 DRFU Double Feeder(2TX+2RX)
2 DRFU (PBT) Single Feeder(1TX+2RX)
NBR Relations: We can use Nastar to check the Neighbors, especially
missing neighbors.
Incoming Internal Inter-Cell Handover Measurement per Cell
Outgoing Internal Inter-Cell Handover Measurement per Cell
Incoming External Inter-Cell Handover Measurement per Cell
Outgoing External Inter-Cell Handover Measurement per Cell
GSM Cell to GSM Cell Outgoing Handover Measurement.
After analysis, if there is LOW HSR between
2 neighbors, and also Cell Outgoing Handover Fail Reconn Fail happens, we

need adjust some handover parameters as below:


Edge HO UL RX_LEV Threshold, default value is 10, recommended value 15.
Edge HO DL RX_LEV Threshold, default value is 19, recommended value
25.
Min DL Power on HO Candidate Cell, default value is 10, recommended
value 0.
Min UP Power on HO Candidate Cell, default value is 10, recommended
value 0.
Min Interval for Consecutive HOs, default value is 4, recommended value 2.
Min Interval for Emerg.HOs, default value is 4, recommended value 2.
Filter Length for TCH Level, default value is 6 , recommended value 3.
Filter Length for TCH Qual, default value is 6, recommended value 3.
DL Qual. Threshold, default value is 55, recommended value 40.
UL Qual. Threshold, default value is 55, recommended value 40.
MR. Preprocessing, default value is YES, recommended value NO.
About the values of parameters, just recommended, you can decide to
choose according to actual situation.
Frequency HSN AND MAIO: Remove any Frequency, HSN, and MAIO clashes.
Data Configuration:

Coverage Parameters:
First Analyze Receive Quality, Level, TA and so on by: Number of MRs based
on TA per TRX
Radio Link Failure Measurement per TRX
Radio Link Failure Measurement based on TA per TRX
Receive Quality Measurement per TRX TCHF Receive Level Measurement
per TRX TCHH
Receive Level Measurement per TRX
Uplink-and-Downlink Balance Measurement per TRX,
Cells with larger TA samples:
Control Coverage parameters for example:
RACH Min.Access Level (dbm), default value is -115, recommended value
-109.
Random Access Error Threshold, default value is 180, recommended value
220. RXLEV_ACCESS_MIN, default value is 8, recommended value 10.
Otherwise, we can adjust down tilt and power to control the coverage.
Interference Parameters: First analyze
High receive level with bad quality
A lot of quality handovers
interference band are bigger than 3,there may be interference by
following :
Radio Link Failure Measurement per TRX
Receive Quality Measurement per TRX TCHF Receive Level Measurement
per TRX TCHH
Receive Level Measurement per TRX
GSM Cell to GSM Cell Outgoing Handover Measurement.
Interference Band Measurement per TRX.
We can adjust the parameters as below:
Radio Link Timeout (SACCH period (480ms)) this parameter is about
downlink, default value is 16, recommended value 52.
SACCH Multi-Frames (SACCH period (480ms)) this parameter is about
uplink, default value is 18, recommended value 36.
T200 FACCH/F(5ms) default value is 50,recommended value 80.
T200 FACCH/H(5ms) default value is 50,recommended value 80.
N200 of FACCH/Half rate, default value is 29, recommended value 50.
N200 of FACCH/Full rate, default value is 34, recommended value 50.if
there is strong interference through monitoring channel interference band,
we need eliminate it.