VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 2 of 31

OBJECTIVE AND SCOPE:


It is the objective of this protocol to describe in detail the methodology to be adopted to validate the
Homo Colloid Mill Machine, Plain, GMP Model with all contact parts SS 316, for use in the
manufacturing process. It is to establish confidence that the Homo Colloid Mill Machine is capable
of consistently operating within established limits and tolerance.
The protocol comprises of the following.
A) Installation Qualification :
It should describe the following
1. Equipment specification as against contained in purchase order.
2. Utilities and services are properly connected.
3. Critical instruments / necessary devices are calibrated and are attached to the equipment.
4. Standard operating procedure are identified and written.
5. Manufacturer's certificate is taken whenever necessary.
B) Operational Qualification :
It should cover the operating parameters set for the equipment operation. Validation of equipment
against these parameters should also be described.
It should also describe.
1. Evaluation of process operation with simulating the product.
2. Qualitative / Quantitative analysis of the simulated product.
3. Reproducibility of performance.
C) Performance Qualification:
It should cover the performance parameters set for the equipment performance. Validation of
equipment against these parameters should also be described.
It should also describe.
01. Equipment validation.
02. Performance qualification evaluation.
03. Final report.
E) Conclusion:
The Homo Colloid Mill Machine meets the acceptance criteria in reference to above parameters are
declared validated and released for use.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 3 of 31

INSTALLATION QUALIFICATION
EQUIPMENT NAME
EQUIPMENT MANUFACTURER
EQUIPMENT LOCATION

: HOMO COLLOID MILL MACHINE


: CIP MACHIERIES PVT. LTD.
:

TABLE OF CONTENTS
01.0 Equipment Features
02.0 Pre Qualification
03.0 Statement of Purpose
04.0 Standard Operating Procedures
05.0 Installation Checklist
06.0 Drawings
07.0 Supporting Utilities
08.0 Deficiency and Corrective Action Report
09.0 Final Report
10.0 Appendix - Reference Documents.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

INSTALLATION QUALIFICATION
01.0 EQUIPMENT FEATURES
EQUIPMENT NAME

: Homo Colloid Mill Machine.

MODEL NO.

: CICM 3 Horizontal Model - Plain

DEPARTMENT

VALIDATION TEAM

NAME

DESIGNATION

SIGNATURE

DATE:

PAGE 4 of 31

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 5 of 31

INSTALLATION QUALIFICATION
02.0 PRE QUALIFICATION
DESIGN PARAMETERS AND CAPACITY: Homo Colloid Mill Machine Horizontal
Plain - GMP Model all contact parts SS 316
STANDARD EQUIPMENT OR MADE
AS PER CUSTOMER DESIGNATION

: Standard Equipment

VENDOR SELECTED

: M/s Cip Machineries Pvt. Ltd.


Ahmedabad.

VENDER'S ADDRESS

: Plot No.1903, G.I.D.C,


Phase IV, Opp. Maradia Steeel Unit No. 3,
Vatva, Ahmedabad.
Gujarat - 382 445

MANUFACTURE'S NAME

: M/s Cip Machineries Pvt. Ltd.


Ahmedabad.

TEAM INVOLVED IN SELECTION OF :


EQUIPMENT AND DESIGN
NAME

DESIGNATION

SIGNATURES

DATE

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 6 of 31

INSTALLATION QUALIFICATION
02.1 PRE QUALIFICATION
EQUIPMENT QUALIFICATION AS PER
PURCHASE ORDER

: Colloid Mill Machine Horizontal


Plain GMP Model all contact
Parts SS 316

EQUIPMENT RECEIVED AS PER P.O.

ANY DEVIATION

CERTIFICATION FROM VENDOR FOR

(A)

MATERIAL OF CONSTRUCTION

ACCEPTED FOR INSTALLATION


INSTALLATION TEAM

INSTALLATION COMPLETED ON

THE EQUIPMENT INSTALLATION IS CARRIED OUT AS PER GUIDELINES FRAMED BY


THE MANUFACTURER.

Confidential
CIP MACHINERIES
PVT. LTD.

02.2

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 7 of 31

INSTALLATION QUALIFICATION

MATERIAL / COMPONENT

SPECIFIED

ACTUAL

(As specified by manufacturer)


Base

FIG : 1

Motor Housing

FIG : 1

3 way cock

FIG : 5

Circulating Pipe

FIG : 5

Main Housing Assembly

FIG : 4

Hopper

FIG : 1

Reviewed & Inspected by :

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

02.3

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 8 of 31

INSTALLATION QUALIFICATION

CRITICAL COMPONENT
NAME

IDENTIFICATION
NO.

Hand-wheel
for
gap
adjustment between stator
and rotor.

N. A.

PURPOSE
For machine micro fine
Adjustment.

RANGE
5 to 10 microns

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 9 of 31

INSTALLATION QUALIFICATION
03.0 STATMENTS OF PURPOSE
The purpose of this protocol is to provide an outline for the inspection of equipment for
static attributes to verify that :

Each installed sub-component complies with the engineering design and equipment data
sheets / specifications.

The system is installed according to the design specifications and manufacturers


Recommendations.

No unauthorized or unrecorded modifications have taken place.

Standard Operating Procedures have been identified and listed.

All supporting utilities are properly connected.

All safety features are accounted for.

All installation-testing reports are available and maintained on file.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 10 of 31

INSTALLATION QUALIFICATION
4.0

STANDARD OPERATING PROCEDURE


NUMBER

REVISION

DATE

Operating
Cleaning
Preventive Maintenance

Comments :
History card is prepared for each equipment, which includes preventive maintenance.

Reviewed & Inspected by: ________________________ Date:

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 11 of 31

INSTALLATION QUALIFICATION
05.0

INSTALLATION CHECKLIST
Consideration

No.

Statement

01.

03.

Verify that the "As Built" drawings are complete and represent the design
concept.
Verify that major components are securely anchored and protected from
shock.
Verify that there is no observable physical damage

04.

Verify that there is sufficient room for servicing provided

05.
06.

Verify that all piping and electrical connections have been done according
to the drawings.
All access ports are examined and cleared of any debris.

07.

Walking access to roof mounted equipment provided.

08.
09.

Required electric connections are tight weather proof and grounded.


Equipment identification name plate is visible.

10.

Proper earthing is made

02.

Yes/No

Comments: All the above mentioned consideration are being checked and found satisfactory.

Reviewed & Inspected by:____________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 12 of 31

INSTALLATION QUALIFICATION
06.0

DRAWINGS

Drawings are provided by the manufacturer and are complete.


1. Machine GA Drawing
2. Extension Housing Assembly
3. Main Housing Assembly
4. Cock Body Assembly
5. Wiring Diagram
Reviewed & Inspected by : ______________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 13 of 31

INSTALLATION QUALIFICATION
07.0

SUPPORTING UTILITIES

List the supporting utilities and record whether or not they are properly connected and identified.
Utility

Properly Connected and


Identified (Yes/No)

Electrical connection 3 phase

Comments : Utilities are properly attached.

Reviewed & Inspected by : ______________________

Date :

Checked by

Date

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 14 of 31

INSTALLATION QUALIFICATION
08.0

DEFICIENCY AND CORRECTIVE ACTION REPORT

Description of deficiency and date observed:


No deficiency found during installation.
_______________________________________________________________________________
_______________________________________________________________________________
Person responsible for corrective action and date assigned:
_____________________________________N.A.______________________________________
_______________________________________________________________________________
_______________________________________________________________________________
Corrective actions taken and date conducted :
_____________________________________N.A.______________________________________
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
SIGNATURES
Conducted by: _____________________
Approved by: _____________________

Date :
Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 15 of 31

INSTALLATION QUALIFICATION
09.0

FINAL REPORT

09.1

Summary :
The equipment is procured as per specification of M/s Alembic Limited
Installation is carried out as per manufacturers recommendations. Supporting utilities
are connected.

09.2 Analysis / Evaluation :


The machine is installed at the location. Supporting utilities are well connected and
functioning properly. Standard operating procedure are identified and listed. History card
is prepared for the equipment. All relevant critical document and drawing are
supplied by the manufacturer.
09.3

Certification :
Installation of Colloid Mill Machine is done and found satisfactory.

Reviewed & Inspected by : ___________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 16 of 31

INSTALLATION QUALIFICATION
10.0

APPENDIX
Abbreviations and Definition
Reference Documents

A) Instruction Manual of M/s. Cip Machineries Pvt. Ltd.


B) Following Drawings of Homo Colloid Mill Machine are available in instruction manual.
Base

FIG : 1

Motor Housing

FIG : 1

3 way cock

FIG : 5

Circulating Pipe

FIG : 5

Main Housing Assembly

FIG : 4

Hopper

FIG : 1

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 17 of 31

INSTALLATION QUALIFICATION
10.1

APPENDIX (Continued)

Reference Documents
01.

Manufacturers Brochure (s) / Manual (s) (Title and Location).

_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
02.
Purchase Order. Attached (Yes / No.) If no, state Location.
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________
_______________________________________________________________________________

Reviewed & Inspected by : _________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

OPERATIONAL QUALIFICATION
EQUIPMENT NAME
: HOMO COLLOID MILL MACHINE
EQUIPMENT MAKE
: CIP MACHINERIES PVT. LTD.
EQUIPMENT LOCATION :
TAB LE O F C O N T E N T S
1.0

System Description

2.0

Statement of Purpose

3.0

SOP Verification

4.0

Safety Features Test

5.0

Simulation of process

6.0

Maintenance Schedule

7.0

Final Report

PAGE 18 of 31

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 19 of 31

OPERATIONAL QUALIFICATION
01.0 SYSTEM DESCRIPTION
CIP, Homo Colloid Mill Machine is a machine for milling of viscous liquid and paste. The hopper
capacity is 15 liters and electrical motor 3 Hp, 2850 RPM, 3 Phase. The unit consists of:

Motor Housing Assembly


Extension Housing Assembly
Main Housing Assembly
Hopper
Cock Body Assembly

The speed of the rotor is very high. To increase the gap between stator and rotor, de-lock the
handles by unscrewing the turn adjusting ring by rotating the handles anticlockwise and to increase
the milling rotate the handles clockwise and also lock the handles.
Due to the slightly deviating tapering of the milling surfaces of stator and rotor, the gap becomes
narrower towards the discharge section. The special design type facilitates adjustment of the
grinding gap by an exterior screw ever during operation.
By three-way cock assembly we can re-circulate liquid type product till you get your required
result.
The system has utilities like electrical connection and vacuum connection connected to it.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 20 of 31

OPERATIONAL QUALIFICATION
NAME OF EQUIPMENT: HOMO COLLOID MILL MACHINE
02.0

STATEMENT OF PURPOSE

The purpose of this protocol is to validate the above equipment for the operational qualification to
1. Demonstrate that the equipment / system will perform reproductivity and consistently within its
full dynamic range of operation according to manufacturers specifications.
2. Documents initial performance of the equipment / system.
3. Assure that the equipment / system performance is adequate to support the process for which the
system is designed.
4. Demonstrate the suitability of the SOP is established for the equipment / system.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 21 of 31

OPERATIONAL QUALIFICATION
03.0 SOP VERIFICATION :
Subject

: Standard Operating procedure for the operation of


Homo Colloid Mill Machine.

Testing Date

Operating Personnel :

Observing Personnel :
Observation

Observation - Yes / No
(If no state why in comments)

Most current revision in use


Operating Personnel understand and follow SOP
description and requirements.
SOP provides adequate direction and control to
ensure uniform equipment operation.
Comments : Machine is operated as per Standard Operating Procedure.

Reviewed & Inspected by : _____________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 22 of 31

OPERATIONAL QUALIFICATION
04.0

SAFETY FEATURE :

1. Safety Provision against leakage of the liquid:


Oil seals and O rings are provided to avoid the leakage of the liquid and prevent the main motor.
If any seal will damage you can see the liquid at the particular portion, so by replacing that seal we
can avoid further damage.

Checked by ____________________________________Date:

Inspected by: _____________________________________Date:

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 23 of 31

OPERATIONAL QUALIFICATION
05.0

EQUIPMENT VALIDATION THROUGH SIMULATION OF THE PROCESS.

The simulation of the process was carried out by milling of the liquid or suspension.
Simulation of the process consist of the following:
A)

Milling of liquid or suspension has been done at desired particle size and to check it.

B)

Particle size has been checked for its effectiveness in decreasing and increasing
of the gap between the stator and rotor by handles.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 24 of 31

OPERATIONAL QUALIFICATION
05.1
Stage / Parameter
1. At Maximum Milling
Condition
2. At Optimum Milling
Condition
3. At Minimum Milling
Condition

Location / Sample
Liquid from the coke

Tests
Particle size reduction

Liquid from the coke

Particle size reduction

Liquid from the coke

Particle size reduction

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

05.2 QUALITY CONTROL RESULT


PHYSICAL APPEARANCE
A.

Sample from the Hopper before milling

B.

Sample from the container after milling

PAGE 25 of 31

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 26 of 31

OPERATIONAL QUALIFICATION
05.3

DATA EVALUATION AND CONCLUSION :


Based on the quality control results generated by simulating the process and its review, it
can be said that machine performs satisfactory and producing tablets conforming to the
acceptance criteria.

Reviewed by : _____________________

Date :

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 27 of 31

OPERATIONAL QUALIFICATION
06.0

MAINTENANCE SCHEDULE
Check list

SR.NO.
1
Check for cleanliness of hopper, stator, rotor, circulating pipe, 3 way cock.
2
Check visually any leakage of liquid from extension housing due to oil seal
or O ring damage
3
Check the all rubber packing
4
Lubrication of grease nipples of Housing.
5
Check motor mounting bolts.
6
Check / Clean electrical connection and contact points

D = Daily

W = Weekly

M = Monthly

Inspected by : ___________________________

Date :

D
D
D
W
M
M

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 28 of 31

OPERATIONAL QUALIFICATION
07.0

FINAL REPORT
Summary
Analysis / Evaluation
Certification
The operation of the equipment HOMO COLLOID MILL MACHINE was carried
out as per standard operating procedure. The equipment performs within the assigned limits
when operated as per approved standard operating procedure.
Operating parameters that have a significant impact on the equipment ability to operate and
achieve the process are satisfactory and conforms to the acceptance criteria.
The equipment HOMO COLLOID MILL MACHINE
MODEL NO.

: CICM 3 HORIZONTAL

DEPARTMENT

Purpose

: Milling of viscous liquids and pastes.

Frequency of Validation : Validation due on Date_________or the event of any change in


critical component of the machine.
"THE EQUIPMENT "HOMO COLLOID MILL MACHINE" IS VALIDATED
AND RELEASED FOR USE.
DATE

WORKS MANAGER

MAINTENANCE
MANAGER

Q.C. MANAGER

Q.A. MANAGER

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PERFORMANCE QUALIFICATION
EQUIPMENT NAME
: HOMO COLLOID MILL MACHINE
EQUIPMENT MAKE
: CIP MACHINERIES PVT. LTD.
EQUIPMENT LOCATION :
TAB LE O F C O N T E N T S
1.0

Statement of Purpose

2.0

Final Report

PAGE 29 of 31

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 30 of 31

PERFORMANCE QUALIFICATION
NAME OF EQUIPMENT: HOMO COLLOID MILL MACHINE
01.0

STATEMENT OF PURPOSE

The purpose of this protocol is to validate the above equipment for the performance qualification to
1. The equipment / system will perform reproductively and consistently within its full dynamic
range of performance according to manufacturers specifications.
2. Documents initial performance of the equipment / system.
3. Assure that the equipment / system performance is adequate to support the process for which the
system is designed.
4. Demonstrate the suitability of the SOP is established for the equipment / system.

Confidential
CIP MACHINERIES
PVT. LTD.

VALIDATION PROTOCOL FOR


HOMO COLLOID MILL MACHINE

PAGE 31 of 31

PERFORMANCE QUALIFICATION
02.0

FINAL REPORT
Summary
Analysis / Evaluation
Certification
The performance of the equipment HOMO COLLOID MILL MACHINE was
carried out as per Standard Operating Procedure. The equipment performs within the
assigned limits when operated as per approved standard operating procedure.
Operating parameters that have a significant impact on the equipment ability to perform and
achieve the process are satisfactory and conforms to the acceptance criteria.
The equipment HOMO COLLOID MILL MACHINE
MODEL NO.

: CICM - 3 HORIZONTAL

DEPARTMENT

Purpose

: Milling of viscous liquids and pastes.

Frequency of Validation : Validation due on Date_________or the event of any change in


critical component of the machine.
"THE EQUIPMENT "HOMO COLLOID MILL MACHINE" IS VALIDATED
AND RELEASED FOR USE.
DATE

WORKS MANAGER

MAINTENANCE
MANAGER

Q.C. MANAGER

Q.A. MANAGER