18TRES
Residential Gas
Multi-Fuel LP Vapor/Natural Gas
Standard Features
D ADC-RES Advanced Digital Control
d Designed for todays most sophisticated electronics
d Electronic speed control responds quickly to varying
household demand
d Digital voltage regulation protects your sensitive
electronics from harmonic distortion and unstable power
quality
d LED display shows system status and setup information
D Engine Features
d Kohler Command PROr OHV engine with hydraulic
valve lifters for reliable performance without routine
valve adjustment or lengthy break-in requirements
d Digital Spark Advance Ignition (DSAI) optimizes engine
performance for natural gas and LP vapor fuels
d Simple field conversion between natural gas and LP
vapor fuels while maintaining emission certification
d Engine-mounted battery charging alternator
D Faster Response
Kohlerr generators restore power in as little as 10 seconds
D Quiet
Quiet operation: 68 dB(A) at 7 m (23 ft.) maintains
neighborhood solitude
D Premium Five-Year Limited Warranty
Generator Ratings
Standby Ratings,
Natural Gas
LP Gas
Voltage
Phase
Hz
Alternator Model
kW/kVA
Amps
kW/kVA
Amps
230/400
50
2G5
12.9/16.1
23.3
12.9/16.1
23.3
RATINGS: Standby ratings apply to installations served by a reliable utility source. All three-phase units are rated at 0.8 power factor. The standby rating is applicable to variable loads with an average
load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL
GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 1.5% per 5.5_C (10_F) temperature increase above 16_C
(60_F). Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your
local Kohler Co. generator distributor for availability.
*
Due to the cycling operation of many electrical appliances, the generator set may not run all appliances simultaneously. Check the appliance manufacturers specifications for actual power
requirements. Consult a Kohlerr Power Systems professional for your exact residential power system requirements.
G4-158 (18TRES)
6/09
Application Data
Engine
Engine Specifications
Manufacturer
Engine: model, type
Cylinder arrangement
Displacement, cc (cu. in.)
Bore and stroke, mm (in.)
Compression ratio
Main bearings: quantity, type
Rated rpm
Max. engine power at rated rpm,
kW (HP)
LP vapor
Natural gas
Cylinder head material
Valve material
Piston type and material
Crankshaft material
Governor: type
Frequency regulation, no load to full load
Frequency regulation, steady state
Air cleaner type
Operation Requirements
Kohler
CH980 4 Cycle
V-2
999 (61)
90 x 78.5 (3.54 x 3.1)
8.8:1
2, Parent Material
3000
20.0 (26.8)
16.8 (22.5)
Aluminum
Steel/Stelliter
Aluminum Alloy
Heat Treated, Ductile Iron
Electronic
Isochronous
0.5%
Dry
Fuel System
Fuel types
1.7--2.7 (7-11)
Natural Gas
(242,000 Btu/hr.)
LP Vapor
(280,000 Btu/hr.)
8 (25)
3/4
15 (50)
30(100)
1 1/4
46(150)
1 1/4
1 1/4
61(200)
1 1/4
1 1/4
Electronic, DSAI
12
15
100%
5.7
(203)
75%
4.7
(167)
50%
3.8
(133)
25%
2.9
(103)
LP Vapor,
Negative
12
1
525
m3/hr.
(cfh)
100%
2.7
(94)
75%
2.2
(79)
50%
1.7
(62)
25%
1.4
(50)
100%
5.0
(11.0)
75%
4.2
(9.3)
50%
3.3
(7.2)
25%
2.6
(5.8)
4.4 (155)
216 (420)
Lubrication
Lubricating System
Type
Oil capacity (with filter), L (qt.)
Oil filter: quantity, type
Oil cooler
Fuel Requirements
% Load
Exhaust
Exhaust System
Exhaust flow at rated kW,
m3/min. (cfm)*
24 (848)
23 (798)
1.4 (50)
Engine Electrical
Engine Electrical System
Ignition system
Starter motor rated voltage (DC)
Battery charger, ampere rating
Battery (purchased separately):
Ground
Volts (DC)
Battery quantity
Recommended cold cranking amps
(CCA) rating for --18_C (0_F)
Cooling Air
Total inlet air,
m3/min. (cfm)
Full Pressure
2.8 (3.0)
1, Cartridge
Integral
Alternator
ADC-RES Controller
Alternator Features
D Compliance with NEMA, IEEE, and ANSI standards for
temperature rise
D Self-ventilated and dripproof construction
D Vacuum-impregnated windings with fungus-resistant epoxy
varnish for dependability and long life
D Superior voltage waveform and minimum harmonic distortion
from skewed alternator construction
D Digital voltage regulator with 1.5% no-load to full-load RMS
regulation
D Rotating-field alternator with static exciter for excellent load
response
D Skewed generator construction produces a smooth
AC waveform
Alternator Specifications
Specifications
Manufacturer
Output voltage
Type
PowerBoostt Generator
3-Phase
Kohler
230/400
2-Pole, Rotating Field
Leads, quantity
Voltage regulator
Insulation:
12
Digital
NEMA MG1-1.66
Material
Class H
Temperature rise
Class H
1, Sealed Ball
Direct
Full
1.5%
100% of Rating
38
Controller Features
D Membrane keypad:
d Arrow keys step through generator set status displays
d Password-protected access to system configuration and
adjustment menus
d System voltage/frequency selection and engine
configuration
d Voltage, gain, and engine speed adjustment
D LED display:
d Engine runtime, hours
d Output voltage, VAC
d Output frequency, Hz
d Battery voltage, VDC
d Crank cycle status
d Setup information
d Software version
d Faults
D Faults displayed:
d High battery voltage
d High engine temperature
d Low battery voltage
d Low oil pressure
d Overcrank
d Overfrequency
d Overspeed
d Overvoltage
d Underfrequency
d Undervoltage
D Compact controller integrally mounted to the generator set
D Remote two-wire start/stop capability
D Digital isochronous governor to maintain steady-state speed
at all loads
D Digital voltage regulation: 1.5% RMS no-load to full-load
D Automatic start with programmed cranking cycle
D Field-upgradeable application software
D Front-access DB9 connector for software upgrade
on the junction box
D Generator set master switch (Run/Off-Reset/Auto)
on the junction box
G4-158 (18TRES)
6/09
Standard Features
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
D
Weight:
Shipping weight:
NOTE: This drawing is provided for reference only and should not be used for planning
installation. Contact your local distributor for more detailed information.