Distance protection relays

Line differential protection relays

30

series
model
Case size
CT Inputs
VT Inputs
Opto Inputs (max)
Output Contacts (max)
RTDs (option)
Analogue Input/Output (max)
Function keys/hotkeys
Bay control & monitoring
with Mimic
Interlocking logic

P442

P443

Distance

21/21N

P542

P543

P544

P545

P546

P547

80TE

60TE

60TE

60TE

80TE

80TE

80TE

CT Inputs

VT Inputs

4 or 5

16

24

Opto Inputs (max)

46

16

16

16

32

24

24

Output Contacts (max)

30

14

14

14

32

32

32

Compact

84TE

40TE

60TE

4 or 5

4 or 5

4 or 5

4 or 5

4 or 5

70

82

36

70

16

32

24

32

48

48

28

14

21

32

46

16

32

1/2

1/2

1/2

1/2

25

P444

P445

80TE

80TE

40 or
60TE

P446

Function Keys/Hotkeys

Interlocking logic
PROTECTION FUNCTION

32

46

46/67

46BC

49

P521 P530C P532

40TE

40 or
84TE

model

P541

P439

40

40 or
84TE

P437

40 or
84TE

30
Compact

P435

40 or
84TE

20
30TE

P433

ANSI

20

P441

series
Case size

P430C

PROTECTION FUNCTION

Check synchronising
Directional power
Negative sequence
overcurrent
Directional negative sequence
Broken conductor
Thermal overload
Switch on-to fault
Earth fault
Phase overcurrent
Stub bus protection
Over/Undervoltage
Residual overvoltage
Circuit breaker failure
Earth fault directional
Transient earth fault
directional
Phase directional
Wattmetric earth fault
Out of step tripping
Power swing blocking
Autoreclose
Over/Under frequency
Rate of change of frequency
Channel aided scheme logic
Capacitive voltage
transformer supervision
Trip Circuit Supervision
Voltage/Current transformer
supervision
Delta directional comparison
Neutral admittance
InterMiCOM
Mutual compensation

40

ANSI

Distance

21

Check synchronising

25

Loss of load/Undercurrent

37

Negative sequence
overcurrent

46

Thermal overload

49

Earth fault
Phase overcurrent

50/51N

50/51P

Circuit breaker failure

50BF

50/27

Over/Under voltage

59/27

50/51N

Wattmetric earth fault

64W

50/51P

50ST

Earth fault directional

67N

59/27

67N

59N

Sensitive directional earth


fault

62/50BF

Phase directional

67P

67N

67N

67P

67W

68

78

79

3 pole

3 pole

81

81R

85

3 pole

3 pole

1/3 pole 1/3 pole

CVTS

1/3 pole 1/3 pole 1/3 pole

3 pole

Autoreclose

79

3 pole

3 pole

3 pole

81

Line differential (terminal)

87L

Phase comparison

87L

CT supervision

CTS

Trip Circuit Supervision

TCS

2nd harmonic restraint

Copper wire signalling

1/3 pole

78

Under/Over frequency

Power swing blocking

2/3

2/3

1/3 pole 1/3 pole 1/3 pole 1/3 pole 1/3 pole

2/3

2/3

2/3

2/3

2 breaker configuration

TCS

Direct/Permissive inter
tripping

VTS/CTS

FO signalling

In Zone transformer

l/V
YN

PLC signalling

SDH/Sonet networks
Vector Compensation