Anda di halaman 1dari 10

Vickers

SystemStak Valves, D08

DGMFN-H8, 10 Design Throttle Valve


DGMPC-H8, 10 Design Pilot Operated Check Valve

315 bar
Size ISO 08

Table of Contents

DGMPC-H8, SystemStak Valve, Pilot Operated Check


General Information......................................................................................................................................................................... 2
Functional Symbols.......................................................................................................................................................................... 2
Model Codes................................................................................................................................................................................... 3
Flow Curves..................................................................................................................................................................................... 3
Technical Data.................................................................................................................................................................................. 3
Dimensions...................................................................................................................................................................................... 4
Released Part Numbers................................................................................................................................................................... 8
DGMFN-H8, SystemStak Valve, Throttle Valve with Check
General Information......................................................................................................................................................................... 5
Functional Symbols.......................................................................................................................................................................... 5
Model Codes................................................................................................................................................................................... 6
Technical Data.................................................................................................................................................................................. 6
Flow Curves..................................................................................................................................................................................... 6
Dimensions...................................................................................................................................................................................... 7
Released Part Numbers................................................................................................................................................................... 8

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Series DGMPC-H8
General
Description

3
A1

Features:
Industry Standard Mount-
ing, ISO 4001-8, NFPA
T 3.51 M R1 and ANSI B
93.7 D08
For use in vertical stacking
assemblies
For the leak free closure of
one or both service ports

B1

General
opposite direction is blocked.
The fluid flows from A1 to
The DGMPC hydraulic
A2, the piston (1) is presoperated check valve is of a
surized and is pushed to the
sandwich plate design. They
are used for leak-free closure right, thereby opening the
ball poppet (2) which then
of one or both service ports,
even for long periods of time. opens the main poppet (3). In
order to ensure correct closFree flow occurs from A1 to
B2
ing of the valve, the service
A2 or B1 to B2. Flow A2
in the

ports of the directional valve


must be connected to tank
in the neutral position (see
typical circuit).

Z2S6

1 Piston
2 Ball Poppet
3 Main Poppet
4 Area A1
5 Area A2
6 Area A3

5
A1

A2

Typical Circuit

A2

B2

Symbols

B1

A2

B2

A1

B1

B2 A

A2

B2

A2

B2

A2

B2

A1

B1

A1

B1

A1

B1

AB*- BA*
A1

AB*

BA*

B1

T
EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Series DGMPC-H8
Model Code

(F3)

DGMPC H8 AB * (BA) (*) 10

Blank Nitrile, for Mineral



oil Anti-wear

hydraulic oil (class

L - HM), Invert emul-

sion (class L - HFB)

Water glycol

(class L - HFC)

 tack module, piloted


S
operated check valve

4 Check Valve Line


AB - A piloted from B
BA - B piloted from A
(Single line only)

Technical Data

5 Cracking Pressure
K
 3 Bar
L
 5 Bar
M
 7.5 Bar
N
 10 Bar

3 Size

D08

Check Valve Line


BA - B piloted from A
(Dual line only)

3.0

Solid Line
A1 - A2; B1 - B2
Dotted Line
A2 - A1; B2 - B1

Pressure Drop (bar)

Maximum Flow (L/min)


2.5
Maximum Operating Pressure (bar)
Cracking Pressure
2.0
Area Ratio
1.5
Fluid
1.0
Fluid Temperature Range (0C)
2

Fluid Viscosity Range (mm /S) 0.5
Fluid Cleanliness Level (ISO)
Weight (Kg)
0 20 40 60 80 100 120 140

Characteristic Curves
(measured at v = 41
mm2/s and t = 50OC)

Design Number

10

4
450
3
315
2 3
See Characteristic Curves graph page
1
A1/A2 = 1/13.6;A3/A2 = 1/2.8
Mineral oils or phosphate ester
-20 to 80
2.8 to 500
19/17/14
12 180 200 220 240 260 280 300
160

Flow in L/min
30

25

M
L

20

15
10
5
0

50

100

150 200 250 300


Flow in L/min

Cracking Pressure:
K = 3 bar
L = 5 bar
M = 7.5 bar
N = 10 bar

7 Cracking Pressure (Dual


line only)
K
 3 Bar
L
 5 Bar
M
 7.5 Bar
N
 10 Bar

Pressure Differential in MPa

1 Seal Options
F3 Fluorocarbon seals,

for Phosphate

Ester (class L - HFD)

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

350

400

450

Series DGMPC-H8
Unit Dimensions
(Dimensions in mm)
2.2

2.1

270
270
240

59

100

300
2
2 x 6.5/deep 8
94.3

Y
92

117

L
A

46

96.8

29.2
53
41.4
71.4

77
130
Required surface finish of mating face

0.01/100mm
0.8

1
2
2.1
2.2
3
4
5
6

Cracking pressure 3 bar or 5 bar, check valve on both ports A and B


Cracking pressure 7.5 bar or 10 bar, check valve on both ports A and B
Cracking pressure 7.5 bar or 10 bar, check valve on port A
Cracking pressure 7.5 bar or 10 bar, check valve on port B
Name plate
Valve mounting holes, 6 x 15mm
Locating pins
Locating pin hole

Mounting bolts: -UNC, SAE, Grade 8; M14, DIN912-10.9; ISO 898, Class 12.9
Torque 150 lb-ft (250 Nm)
O-rings: 27mm x 3mm for ports A,B,P and T.
O-rings: 19mm x 3mm for ports X,Y, and L.

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Series DGMFN-H8
General Description

Features:
Industry standard mount-
ing, ISO 4401-8, NFPNA-T-3
.5.1-M-R-I, ANSI B 93.7
D08
Sandwich plate design
Limiting of main flow of
two actuator ports
Meter-in or meter-out
control

General
DGMFN valves have double
throttle/check valves in a
sandwich plate design. They
are used to limit main flow
at one or two actuator ports.
Two symmetrically arranged
throttle/check valves limit
flow (by means of adjustable
throttle spools) in one direction and permit free return
flow in the other direction.

Main flow limiting


The double throttle/check
valve is fitted between the
directional valve and the
subplate to change the speed
of an actuator (main flow
limiting)

3
2
1

1
2
3
4
5

Throttle Adjustment Screw


Spring
Spool
Valve Body
O-Ring

Symbols

Meter-in control...X

Meter-out control...Y

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

A Meter-out control
B Meter-in control: YX

A Meter-in control
B Meter-out control: XY

Series DGMFN-H8
Model Code

F3 DGMFN
1

H8 * A2W-B2W 10

6
Throttle flow pressure drop

Blank Nitrile, for Mineral



oil Anti-wear

hydraulic oil (class

L - HM), Invert emul-

sion (class L - HFB)

Water glycol

(class L - HFC)

S
 tack module, throttle
valve with check

Control line (Wrench


250
adjustment)
Both port A and B

Size

D08

Design number

4 Direction of flow
control
Y Meter out
X Meter in
YX Meter out A, meter
in B
XY Meter in A, meter
out B

10

80
60
40

11
12

20

13
15
17

10
5
1
0

Throttle flow pressure drop

Pressure Drop in bar

350
31550 100 150 200 250 300
Mineral oils or phosphate ester
-20 to + 80
2.8 to 500
19/17/14
8

350

Check free flow pressure drop

DGMFN-H8

4 5

100

Maximum Flow (L/min)


Maximum Working Pressure (bar)
Fluid
Fluid Temperature Range (0 C)
Fluid Viscosity Range (mm2/S)
Fluid Cleanliness Level (ISO)
Weight (Kg)

200

100
10

80
60
40

11

DGMFN-H8
40
30
20
10
0

60

120

180

240

300

360

Flow in L/min

Throttle setting in turns

150
Pressure Drop in bar

150

Technical Data

250

200

Characteristic Curves
(measured at
v = 41 mm2/s and
t = 50OC)

DGMFN-H8

4 5

Throttle setting in turns

Seal Options
F3 Fluorocarbon seals,

for Phosphate

Ester (class L - HFD)

Pressure Drop in bar

12

20

13
15
17

10
5
1
0

50

100

150

200

250

300

350

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Series DGMFN-H8
Unit Dimensions
(Dimensions in mm)

324.7

117

55

268
188

112.5
76.8
53
29.2

2 x 6.5/deep 8

5.6

P
A

Y
B

17.2

17.5
19

46

73
74.5
92
96.8

17.3
77
100.6
130

6 x 15

40.8
Required surface finish of mating face

0.01/100mm
0.8

1
2
3
4
5
6
7
8

Name plate
Screw for flow adjustment
Turn anti-clockwise = increases flow, turn clockwise = decreases flow
Two locating pins
Two locating pin holes
Valve mounting holes
O-ring ports A,B,P,T
O-ring ports X,Y,L

Mounting bolts: -UNC, SAE, Grade 8; M14, DIN912-10.9; ISO 898, Class 12.9
Torque 150 lb-ft (250 Nm)
O-Ring: 27mm x 3mm for port A,B,P and T
O-Ring: 19mm x 3mm for port X,Y, and L

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Released Part
Numbers

Model Code

Part Number

DGMFN-H8-X-A2W-B2W-10
DGMFN-H8-Y-A2W-B2W-10
F3-DGMFN-H8-X-A2W-B2W-10
F3-DGMFN-H8-Y-A2W-B2W-10
DGMPC-H8-ABK-10
DGMPC-H8-ABK-BAK-10
DGMPC-H8-ABL-10
DGMPC-H8-ABL-BAL-10
DGMPC-H8-BAK-10
DGMPC-H8-BAL-10
F3-DGMPC-H8-ABK-10
F3-DGMPC-H8-ABK-BAK-10
F3-DGMPC-H8-ABL-10
F3-DGMPC-H8-BAK-10
F3-DGMPC-H8-BAL-10
Seal Kit
Seal Kit (F3)

02-413087
02-413088
02-413089
02-413090
02-413112
02-413055
02-413054
02-413056
02-413114
02-413059
02-413113
02-413058
02-413057
02-413115
02-413060
02-413807
02-413828

Note: Items in bold have better lead-times.

EATON Vickers SystemStak Throttle Check Valve V-VLST-MC002-E1 September 2009

Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 952-937-9800
Fax: 952-294-7722
www.eaton.com/hydraulics

2009 Eaton Corporation


All Rights Reserved
Printed in USA
Document No. V-VLST-MC002-E1
September 2009

Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +41 (0) 21 811 4600
Fax: +41 (0) 21 811 4601

Eaton
Hydraulics Group Asia Pacific
Eaton Building
4th Floor, No.3 Lane 280 Linhong Rd.
Changning District
Shanghai 200335
China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 5200 0400

Anda mungkin juga menyukai