Anda di halaman 1dari 4

EHE-N1K5TL

Date2010-8-25

1500W

Product Feature:
Highly efficient and stable components from
internationally recognized brands;
Efficient thermal system design reduces risk of
overheating, increasing lifespan;
Advanced MPPT (Maximum Power Point Tracking)
algorithms - MPPT efficiency >99.9%;
High performance index with wide power range;
Anti-islanding technology;
Advanced, highly reliable system protection;
LCD display with wide range of features and language options;
Easy to install,operate and maintain;
Passed multiple stringent performance test,
Suitable for indoor and outdoor installations.

Technical Parameter:
PV side
Max. PV power
Max. Permitted DC Voltage
Input Short-circuit Current
Max. Permitted DC Current
MPPT Points
String Number
MPPT range
PV Start Voltage
MPPT Voltage Range
Max. Inverter Feedback Current to the Array
Grid side
Rated Output Power
Max. Output Current
THD of Grid Current
Power Factor
Max. efficiency

1.65kWp
520V
12.5A
10A
1
1
125~420Vdc
150Vdc
99.9%
0A
1.5kW
6.9A
<3%
>0.99
96.5%

European efficiency
Output Voltage
Permitted Grid Frequency Range
Standby Power Consumption
Nighttime Power Consumption
Grid Monitoring

95.5%
180~260Vac
47.5~51.5Hz
5W
0W
According to VDE0126-11guidelines
RS485/Ethernet
(optional)/GPRS(optional)
LCD

Communication Interface
Man-machine Interface
Environmental Conditions and safety
Protective Level
Cooling
Operating Temperature Range
Relative Humidity Range
Mounting Altitude
Noise Emissions

Meet the Standards

IP65
Natural Cooling
-25~+60
0~98% (non condensing)
2000m; above 2000m need
derate operating
<45dB@1m
IEC 62103; EN 50178;
IEC/EN 62109-2; IEC/EN
61000-6-1:2007;IEC/EN
61000-6-3:2007;IEC/EN
61000-3-3:2007; AS/NZS
3100:2009; AS4777.2:2005;
AS4777.3:2005

Mechanical
Dimensions W/H/D
Weight

325/475/170 mm
14kg

EHE-N2KTL
Date2010-8-25

2000W

Product Features:
Highly efficient and stable components from
internationally recognised brands;
Efficient thermal system design reduces risk
of overheating, increasing lifespan;
Advanced MPPT(Maximum Power Point Tracking)
algorithms-MPPT efficiency >99.9%;
High performance index with wide power range;
Anti-islanding technology;
Advanced, highly reliable system protection;
LCD display with wide range of features and
language options;
Easy to install, operate and maintain;
Passed multiple stringent performance tests;

Suitable for indoor and outdoor installations.

Technical parameters:
PV side
Max. PV power
2.2kWp
Max. Permitted DC Voltage
520V
Input Short-circuit Current
16.25A
Max. Permitted DC Current
13A
MPPT Points
1
String Number
1
MPPT range
125~420Vdc
PV Start Voltage
150Vdc
MPPT
voltage
range
Hybrid Off-Grid Inverter system is a set of battery charging and99.9%
discharging control , PV mains
Max. Inverter
Feedback
Current
0A system, mainly including PV
switch
control and
inverter
controltointhe
oneArray
multi-functional integrated
Grid side
array,
grid, battery, hybrid off-grid inverter and the AC load, PV array absorption of solar
radiation and Rated
translate
Output
into Power
electrical energy to provide power for
2.0kW
the entire system, utility power
switchover and
Inverting
control
function,
also
could
converting
DC
Max. Output Current
10Apower from battery to supply
power for AC THD
loads.
Priority mode is PV mode. PV controller
of System
Grid Current
<3%and Grid charger achieves
the intelligent battery-charging
control.
The
inverter
inverts
the
DC to AC for the load power
Power Factor
>0.99
supplying ;and automatic
control
the
start-stop
of
Grid
charger
if needed.Try the best to use the
Max. efficiency
96.5%
solar energy and
the
continuous
demand
of
electricity.
It's
the
preferred
European efficiency
95.5% solution to solve the
public grid or less developed areas residents daily electricity.
Output Voltage
180~260Vac
Permitted Grid Frequency Range
47.5~51.5Hz
Standby Power Consumption
5W
Nighttime Power Consumption
0W
Grid Monitoring
According to VDE0126-1-1 guidelines
RS485/Ethernet
Communication Interface
(optional)/GPRS(optional)
Man-machine Interface
LCD
Environmental conditions and safety
Protective Level
IP65
Cooling
Natural Cooling
Operating Temperature Range
-25~+60
Relative humidity range
0~98% (non condensing)
Mounting Altitude
2000m; above 2000m need derate
operating
Noise Emissions
<45dB@1m
IEC62103; EN50178; IEC/EN 621092;IEC/EN 61000-6-1:2007;
Meet the Standards
IEC/EN61000-6-3:2007;IEC/EN
61000-3-3:2007;AS/NZS
3100:2009;AS4777.2:2005;
AS4777.3:2005
Mechanical
325/475/170 mm
2.Internal Dimensions
structure W/H/D
Weight
14kg

Hybrid Inverter including PV Charger,Grid Charger, Inverter and Controller, using a common DC
Bus mode, as the output of Battery, PV Charger, Grid Charger and Inverter merge into DC Bus.
Meanwhile, DC Bus is battery's charging current path, and PV charging is priority than Grid
charging.

Anda mungkin juga menyukai