Oil Sample - Information Lab No:A14H270112, Unit:DT-101, Serial No:0DLS00983 : Hydraulic System

Message: Oil Sample - Information Lab No:A14H270112


Attn: Trakindo Jakarta / Stevanus Parulian (A)
More Information
-----------------------------------------------------------------SAMPLE DETAILS 28-Aug-2014
-----------------------------------------------------------------CURRENT SAMPLE
Customer
INDOCEMENT TUNGGAL PRAKARSA PT. Jobsite
Serial No
Unit No
0DLS00983
Model
Make
775F
Oil Type
Oil Grade
UNKNOWN
Compartment Hydraulic System
Compart Serial
Job No
Meter
Lab No
Sample Date
A14H270112
Eval
Sample Site
A

109233 - CITEUREUP
DT-101
Caterpillar

8744
25-Aug-2014
QUARRY D PT ITP

DETAILS
Lab No
Eval Date Sampled Date Received Label Actioned Meter Read Comp. Hours
A14H270112 A 25-Aug-2014 26-Aug-2014
10
N
8744
8744
A14G240831 B 22-Jul-2014
24-Jul-2014
10
N
8493
8493
A14F250418 B 23-Jun-2014 25-Jun-2014
10
N
8063
8063
A13I280106
B 26-Sep-2013 27-Sep-2013
10
N
5996
5996
Lab No
Eval Si Al
A14H270112 A 25 3
A14G240831 B 25 2
A14F250418 B 26 2
A13I280106
B 8 1

ELEMENT TESTS
Cr Fe Pb Cu Sn Ni Na
1 22 0 3 0 1 6
0 17 0 3 0 1 3
0 13 0 3 0 1 3
0 7 0 7 0 1 0

K
4
0
0
0

Mo
0
0
0
0

Zn
889
786
750
843

Mg Ca
95 3190
91 3033
63 3147
56 2917

P
818
795
768
829

B
0
0
0
0
1

Fluid Hours
0
1013
630
999

Fluid Added
0.00
0.00
0.00
0.00

Fluid Changed Filter Changed


N
N
N
N

LUBRICANT TESTS
Lab No
Eval W V100 PQ PC06 PC14
A14H270112 A N 10.32 5 425 48
A14G240831 B N 10.23 1 3425 53
A14F250418 B N 10.92 2 3479 49
A13I280106
B N 8.36 0 6943 202
Lab No
A14H270112
A14G240831
A14F250418
A13I280106

ISO.6
16
19
19
20

ISO.14
13
13
13
15

COMMENTS
Eval Comment
WEAR METALS ARE ACCEPTABLE. ADVISE CHANGING OIL AND FILTER, RESAMPLE AFTER 250 HOURS. BRAND NAME/TYPE OF OIL AND
A
HOURS ON OIL OF SAMPLE ARE NOT STATED ON THE LABEL. SUPPLY COMPLETE DATA TO GET ACCURATE RESULT.
THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE (NEW CLEAN LINES TARGET = 18/15). ELEVATED SI INDICATED DIRT
B HAS ENTERED THE SAMPLE. OTHER READINGS ARE ACCEPTABLE. ADVISE TO CHANGE FILTER, CONTINUE TO SAMPLE AT THE NORMAL
INTERVAL. GRADE OF OIL NOT STATED ON THE LABEL. SUPPLY COMPLETE DATA TO GET ACCURATE RESULT.
THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE. OTHER READINGS ARE ACCEPTABLE. TAKE OIL SAMPLES AT 250
B
HOUR INTERVALS TO MONITOR CONDITION.
THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE (NEW CLEAN LINES TARGET = 18/15). WEAR METALS ARE
B
ACCEPTABLE. CHANGE FILTER, RESAMPLE AT 1250 HOURS ON OIL. CUT OPEN FILTER AND INSPECT FOR LARGE PARTICLES.