A circuit for mains synchronization has two separate outputs for each half-period

Circuito de sincronizao com alimentao e duas sadas separadas para cada meio perodo
Dusan Ponikvar -March 22, 2013

1 Comments

Often a measurement of weak signals has to be performed in the presence of strong interference from the ac power mains. If the interfering signal cannot be
filtered out, then you can still obtain a clean result by making two consecutive measurements separated in time by an odd number of half-periods of the mains and
calculating the average of the two measurements. The interfering signals have opposite polarities in consecutive measurements, and averaging cancels them out. If
you average several consecutive pairs of measurements, the results will improve still further. Instead of counting the half-periods of the mains, you may find that a
circuit having two outputs for synchronization with odd or even half-periods of the mains can come in handy.

Muitas vezes a medio de sinais fracos tem que ser realizada na presena de uma forte interferncia da rede
de alimentao AC. Se o sinal de interferncia no pode ser filtrado, voc ainda pode obter um resultado
limpo fazendo duas medies consecutivas separados no tempo por um nmero mpar de meios perodos de
corrente eltrica e calculando a mdia das duas medies. Os sinais de interferncia tm polaridades opostas
em medies consecutivas, e a mdia cancela-os . Se voc mdir vrios pares consecutivos de medio, os
resultados iro melhorar ainda mais. Em vez de contar os meios perodos de corrente elctrica, voc pode ter
um circuito com duas sadas para a sincronizao com mpares ou pares de meios perodos (half-periods) de
alimentao corrente eltrica (fonte-mains ) que pode vir a calhar.
A Figura 2 mostra os resultados de simulao (utilizando a verso livre do programa TINA-TI). O circuito
de alimentao aceita entrada de 80V a 240V ac , e consome menos de um miliamperes de corrente.

Figure 2 Simulation results demonstrate the circuit action.

Figure 1 Mains zero crossings are marked by the optically isolated outputs.
Cruzamentos de zero da fonte so marcadas pelas sadas isoladas opticamente.
The circuit shown in Figure 1 provides two separate and optically isolated outputs, ISO 1 and ISO2, for synchronization with the desired half-period of the mains.
Figure 2 shows the results of simulation (using the free version of TINA-TI). The circuit accepts mains input from 80V ac to 240V ac, and consumes less than a
milliamp of current.

Figura 1 apresenta duas sadas separadas e opticamente isoladas, ISO 1 e ISO 2, para a sincronizao com a
semi-perodo da corrente eltrica desejado.
The duration of the pulses at outputs ISO 1 and ISO 2 is less than a millisecond, and capacitor C 1 can be adjusted to achieve the exact alignment of the falling edges of outputs ISO1 and ISO2 with the zero crossing of the mains. All diodes, D1 to D5, are small-signal type 1N4148 or similar.
The circuit works as follows: During the positive half-period of the mains, C3 is charged through R1A, R 1B, D1 and D5, D3, R2B, and R2A. The effective time constant, , for charging is about 43 msec, and C 3 barely picks up some charge in the half-period. Once the mains drops below the voltage stored on C 3 (this happens just before the end of the half-period), the charging stops and current begins to flow from C 3 through R3 into the base of Q5, turning it on. This discharges C3 through the LED in optocoupler OC 1, and produces a pulse at the output ISO1 of the circuit. During the negative half-period, the action repeats, only this time D 4 and D2 are used
to charge C2, and R 4 is used to activate Q5 when the negative half-period is nearly finished.

A durao dos impulsos de sadas em ISO 1 e ISO 2 menor que um milsimo de segundo, e o condensador
C 1 pode ser ajustado para atingir o alinhamento exato das arestas descendentes de sadas ISO 1 e ISO 2
com a passagem por zero da fonte . Todos os dodos D, D 1 a 5, so do tipo pequeno-sinal 1N4148 ou
similar.
O circuito funciona como segue: Durante o perodo de meia-positivo de corrente, C 3 carregado atravs de
R1a, R1b, D 1 e D 5, D 3, R 2B e R 2A. O tempo efetivo constante, , para o carregamento de cerca de 43
ms, e C 3 mal pega alguma carga nesse meio-perodo. Quando a corrente eltrica cair abaixo da tenso
armazenada em C 3 (isto ocorre, pouco antes do final do semi-perodo), o carregamento para e a corrente de
carga comece a fluir a partir de C 3 a R3 para a base de Q 5, ligando-o. Isto descarrega C 3 atravs do diodo
emissor de luz em um optoacoplador OC, e produz um impulso de sada na ISO 1 . Durante o perodo de
meia-negativo, a repetio da ao, s que desta vez D 4 D e 2 so utilizados para carregar C 2, e R4
utilizado para ativar Q 5, quando o perodo de meia-negativo est quase concludo.
The duration of the output pulse can be shortened to about 600 sec by increasing the time constanttherefore by increasing the value of resistors R1 and R 2 or capacitors C2 and C 3but this also reduces the range of acceptable input voltages.
The detailed simulation reveals that the maximum voltage on C2 and C 3 is less than 5V, with 250V ac connected to the input; a voltage rating of 10V for the capacitors is sufficient. Additionally, the maximum voltage on C 1 is less than 10V ac, and the reverse voltage on the diodes is less than 6V. The peak current through the optocoupler LEDs is below 8 mA. The only components that are exposed to the mains are input resistors R 1A, R1B, R2A, and R 2B. They have equal values, so each one needs to withstand 25% of the mains voltage.
The measurements obtained from the constructed circuit show good correlation with the simulation results. Figure 3 shows output signals; Figure 4 shows the timing detail of the zero crossing and corresponding output pulse for three different values of C 1.
A durao do impulso de sada pode ser reduzido para cerca de 600 sec, aumentando o tempo constante, portanto, pelo aumento do valor das resistncias R1 e R2 ou condensadores C 2 e C 3 - mas isso tambm reduz a gama de tenses de entrada aceitveis.

A simulao detalhada revela que a tenso mxima em C 2 e C 3 inferior a 5 V, com o AC 250V ligado
entrada; uma tenso nominal de 10V para os capacitores suficiente. Alm disso, a tenso mxima em C 1
for inferior a 10 V de corrente alternada, e a tenso reversa sobre os diodos inferior a 6V. A corrente de
pico atravs dos LEDs acoplador ptico est abaixo de 8 mA. Os nicos componentes que so expostas
corrente de entrada so resistncias de R1A, R1B, 2A, 2B e R. Eles tm valores iguais, de modo que cada
um precisa de suportar 25% da tenso da rede.
. As medidas obtidas a partir do show circuito construdo boa correlao com os resultados da simulao A
Figura 3 mostra sinais de sada; A Figura 4 mostra o detalhe calendrio do cruzamento de zero e
correspondente impulso de sada para trs valores diferentes de C 1.

Figure 3 Measured output signals ISO1 and ISO2 and the mains voltage verify the circuit operation.

Figure 4 C1 determines the position of the pulse leading edge in this detail from the center portion of Figure 3. The
horizontal scale is 200 sec/div. Pulses are vertically shifted for better visibility: C1=0 (upper), 12 nF (middle), and 22 nF
(lower).

References
1.
DIY: Isolated high-quality mains voltagezero-crossing detector.
2.
Matteini, Luca, Mains-driven zero-crossingdetector uses only a few high-voltage parts, EDN, Dec
1, 2011.
1 Comments
WKetel
This is a potentially quite useful circuit, and the concept described for recovering data from below line noise with it is certainly an excellent idea.
Thanks for a useful design idea.

Mar 29, 2013 10:09 AM EDT


Este um circuito potencialmente muito til, eo conceito descrito para recuperar dados a partir de baixo
rudo na linha com ele , certamente, uma excelente ideia.
Graas a uma idia de design til.

http://www.dextrel.net/diyzerocrosser.htm
o mesmo circuito mais completo em
http://d1.amobbs.com/bbs_upload782111/files_40/ourdev_643643NSY57M.pdf
DIY - Isolated High Quality Mains Voltage Zero Crossing Detector

FEATURES
highly accurate mains zero crossing detection
fully isolated and low voltage safe output
ultra-low power consumption; worst case power dissipation < 120mW
produces symmetrical pulses around zero crossings
output pulse stays constant, independent of the mains voltage
very low parts count, no precision components required
all components can be low voltage SMD
works over all voltage ranges (100VAC/240VAC), without modification
50Hz/60Hz compatible
50Hz produces a 1ms ZC pulse, 60Hz produces 0.83ms ZC pulse
highly stable with varying temperature and aging

CARACTERSTICAS
altamente precisa de deteco de cruzamento zero das fontes
totalmente isolado da sada de baixa tenso
ultra-baixo consumo de energia; no pior caso a dissipao de energia <120mW
produz pulsos simtricos em torno dos cruzamentos de zero
pulso de sada permanece constante, independente da tenso de rede
poucas peas, no h componentes de preciso exigidos
Todos os componentes podem ser de baixa tenso SMD
funciona atravs de todas as gamas de tenso (100VAC / 240 VCA), sem modificao
50Hz / 60Hz compatvel
50Hz produz um pulso ZC 1ms, 60Hz produz 0.83ms ZC pulso
altamente estvel com a variao de temperatura e envelhecimento do led do opto-acoplador
Modern electronic equipment are nowadays typically powered by switch-mode power supplies. Due to their high frequency operation, these PSUs have no means of providing mains frequency (and/or phase infor mation) for the low voltage electronics circuitry on the se safe low voltage secondary side. Devices such as lighting controllers, thermostats, motor drives and similar AC-load controlling or monitorin applications, often needs mains phase and/or frequency information. Adding an old type iron core mains transformer for this purpose would be both expensive and clumsy. A suitable zero crossing circuit is often needed.
This DIY project presents one very clever variety of such a zero crossing detector, invented by the autho odern electronic equipment are nowadays typically powered by switch-mode power supplies.

Equipamentos eletrnicos modernos hoje em dia so normalmente alimentados por fontes de alimentao
chaveadas. Devido sua operao de alta frequncia, estes PSU no tm meios de fornecer a frequncia da
rede (e / ou informao de fase) para o lado da baixa tenso dos circuitos eletrnicos. Dispositivos como
controladores de iluminao, termostatos, unidades de automveis e controladores AC ou monitores de
aplicaes semelhantes, muitas vezes precisam da fase e / ou informaes da frequncia da rede. Adicionar
um velho transformador de rede de ncleo de ferro para este fim seria caro e desajeitado. Um circuito de
cruzamento de zero adequado muitas vezes necessrio.
Este projeto apresenta uma variedade DIY muito inteligente de um detector de cruzamento zero, inventado
pela autho odern electronic equipment que hoje em dia so normalmente incrementados nas fontes de
alimentao chaveadas.
OTHER KNOWN ZC-DETECTORS
The Design Idea Isolated circuit monitors ac-line published in EDN the 5th of July 2007, is primarily intended for mains line ac-voltage measurement, and is not optimal for efficient zero-crossing detection. The Design Idea Improved opto coupler circuits reduce current draw, resist LED aging, published 14th of December 2007, also suffers from unnecessary complexity and cannot produce the often required symme trical zero crossing pulses for proper thyristor or triac firing.

Outros conhecidos ZC-DETECTORS


O Projeto Idia "Monitor Isolado de circuito de linha AC", Isolated circuit monitors ac-line publicado em
EDN o dia 5 de julho de 2007, destina-se principalmente para a medio da tenso AC da linha de
alimentao, e no o ideal para uma eficiente deteco do cruzamento zero. O projeto Idea "Circuito optoacoplador melhorado reduz consumo de corrente e resiste ao envelhecimento LED", Improved optocoupler
circuits reduce current draw, resist LED agingpublicado 14 de dezembro de 2007, tambm sofre de uma

complexidade desnecessria e no pode produzir os pulsos simtricos adequados da passagem por zero
muitas vezes necessria para que um thyristor ou triac dispare corretamente.
THIS CIRUIT
The circuit presented here produces constant and well defined zero crossing pulses, centered symmertically around the zero crossings, using very little power and just a few plain vanilla components. The pulse length is virtually independent of the mains voltage, is stable with temperature, and immune against component and optocoupler tolerances and aging. A perfboard prototype is presented in Fig.2.

O CIRCUITO
O circuito aqui apresentado produz pulsos de passagem por zero constantes e bem definidos, centrados
simtricamente em torno dos cruzamentos de zero, usando muito pouco consumo e apenas alguns
componentes . O comprimento do impulso praticamente independente da tenso da rede, estvel com a
temperatura, e imune a tolerncias dos componente e envelhecimento do led do acoplador ptico. Um
prottipo apresentado na Fig.2.

DETAILED DESCRIPTION
The zero crossing circuit consists of the voltage to current converting resistors R1-R2, full-wave rectifier diodes D1-D4, a voltage averaging and storing capacitor C1, the opto-coupler U1, and transistor Q1 that functions as a voltage compa rator. R3 provides base current for Q1, and doubles as an input voltage divider together with resistors R1-R2. R4 limits and sets the current into the opto-coupler LED. D5 provides a proper charge current path for C1, preventing the reverse-biasing of the Q1 b-e junction.

DESCRIO DETALHADA
O circuito consiste da converso da tenso de passagem por zero para corrente nas resistncias R1-R2, mais
um retificador de onda completa nos dodos D1-D4, uma tenso mdia armazenada no condensador C1, um
optoacoplador U1, e um transstor Q1, que funciona como um comparador de tenso. R3 fornece corrente de
base para Q1, e funciona como um divisor de tenso de entrada, juntamente com resistncias R1-R2. R4 a
limitadora de corrente do LED do opto-acoplador . D5 proporciona um caminho da corrente de carga
adequada para C1, impedindo-o de polarizao inversa da juno Q1 b-e de Q1.
Transistor Q1 stays off during the majority of the mains cycle, during which C1 is charged via R1-R2 and D5. Q1 turns on and feeds current from C1 to the opto via R4, whenever the mains voltage (divided by (R1+R2)/R3) is lower than the voltage across C1. The voltage across C1 will reach within about 400ms an equilibrium that defines the final
The output pulse width is fairly constant, independent of the designated AC-line voltage (90 240VAC). This makes this simple zero crossing detector quite unique, since the mains voltage does not affect the pulse width nor its position.

operating point. The voltage across C1 never exceeds 10 volts with the given resistor ratios. The voltage stabilizes at a point when the average current charged equals the average current consumed. The typical pulse width is 1ms at 50Hz, and 0.83ms at 60Hz,when using the component values shown.

Transstor Q1 permanece desligado durante a maior parte do ciclo de alimentao, durante o qual C1
carregado atravs de R1-R2 e D5. Q1 liga e alimenta a corrente de C1 para o opto atravs de R4, sempre que
a tenso da rede (divisor (R1 + R2) / R3) for menor do que a tenso sobre C1. A tenso sobre C1 vai chegar
num equilbrio em cerca de 400ms que define o ponto de operao final. A voltagem atravs C1 nunca
excede 10 volts com as propores dadas pelos resistores. A tenso se estabiliza no momento em que a
mdia atual carregada igual corrente mdia consumida. A largura de pulso tpico de 1 ms a 50Hz, e
0.83ms a 60Hz, quando usado os valores dos componentes mostrados. A largura do impulso de sada
relativamente constante, independente da tenso AC da linha (90 ... 240 VCA). Isto torna este simples

detector de cruzamento de zero bastante singular, uma vez que a tenso de alimentao no afeta a largura
dos impulsos, nem a sua posio.
The circuits total power consumption is a mere 32mW at 120VAC, and barely 120mW at 240VAC. The majority of this power is dissipated in the input resistors R1-R2. The peak current flowing into the optocoupler LED varies almost linearly with the mains voltage. This does not cause any inaccuracies to the zero crossing function, as long as the opto-coupler output is always allowed to saturate - even at the lowest mains voltage. This factor determines the minimum allowed value of the pullup resistor R5. The 4N35 optocoupler has a guaranteed CTR (Current Transfer Ratio) of 100%. If you use another optocoupler, please consider this when
calculating the minimum value for R5. You cannot increase the current fed into the optocoupler led by decreasing R4, if you do not at the same time decrease the total resistance of R1 and R2 with the same ratio. The component values given here are optimized for the best signal quality at the lowest possible power dissipation.

Consumo total de energia do circuito um pequeno 32mW em 120VAC, e apenas 120mW em 240 VCA. A
maior parte desta energia dissipada na entrada pelas resistncias R1-R2. O pico de corrente que flui para o
LED optoacoplador varia quase linearmente com a tenso da rede. Isto no causa quaisquer imprecises para
a funo do cruzamento de zero, enquanto a sada do opto-acoplador sempre permitida para se saturar mesmo na menor tenso de rede. Este fator determina o valor mnimo permitido para o resistor R5 pullup. O
optoacoplador 4N35 tem uma CTR ((Current Transfer Ratio - Taxa de transferncia de corrente) garantida
de 100%. Se voc usar outro optocoupler, por favor considere isso quando fizer o clculo do valor mnimo
para R5. Voc no pode aumentar a corrente introduzida no optocoupler simplesmente diminuindo R4, para
isso, tem que ao mesmo tempo diminuir a resistncia total de R1 e R2 com a mesma relao. Os valores dos
componentes dadas aqui so otimizados para a melhor qualidade do sinal e menor dissipao de energia
possvel.
C2 forms a first-order low pass filter to deal with the real world noisy power lines. By decreasing the 1/f frequency of this filter you can deliberately delay the ZC-pulse. The voltage rating of this capacitor does not to be high since it sees only the same voltage as C1 plus three diode forwards drops. A 16VDC rating would do (or anything higher).

C2 forma um filtro passa-baixa de primeira ordem para lidar com as linhas de energia ruidosas do mundo
real. Ao diminuir a frequncia de 1 / f deste filtro pode deliberadamente atrasar o pulso do Zero Cross (ZC).
A tenso nominal deste condensador no deve ser elevada, uma vez que ele s v a mesma tenso que C1
mais trs diodos em gotas. A classificao 16VDC j suficiente (ou pouco mais).
All components are low cost and low voltage types (<10V), with the exception that R1 and R2 must sustain each half of the maximum peak mains voltage (200 volts). R2 can be omitted if R1 alone can sustain the maximum peak input voltage. In this case use a 390kohm standard resistor. Splitting the input resistor into two (halving the voltage handling requirement) makes it possible to use only SMD-components.

Todos os componentes so de baixo custo e tipos para baixa tenso (<10 V), com a exceo de que R1 e R2
tem de sustentar cada metade da tenso de alimentao mxima de pico (200 volts). R2 pode ser omitido se
R1 sozinho puder manter a tenso de entrada mxima de pico. Neste caso, use um resistor padro 390kohm.
Dividindo a resistncia de entrada em duas (reduz-se para metade a exigncia de manuseio da tenso) faz
com que seja possvel usar apenas componentes SMD.
The oscilloscope screenshot shows the quality and symmetry of the output pulse. The "downhill" trace is the mains voltage at 20V/div vertical scale, zero volts is at the sceen centerline. The other trace is the output with a 5V/div scale factor. The timebase is 500s per division. The output pulse is beautifully symmertic around the mains zero crossing.
Even huge temperature variations have a minuscule effect on the zero crossing pulse, due to the self-biasing nature of the circuit. The tolerance of C1's capacitance has no effect either. The circuits resistor ratios set mainly the operation point, and that is the reason is why the output pulse is almost temperature independent.
The picture on the right is a simulated responce for two extreme mains voltages (100VAC...240VAC). You can see that the pulse width variation is minuscule, being less than 100us over the whole mains voltage range. Real behaviour of the actual circuit is equal.

A captura de tela do osciloscpio mostra a qualidade e a simetria do impulso de sada. O trao "downhill" a
tenso de rede na escala vertical de 20V / div, zero volts na linha central sceen. O outro trao a sada
com na escala de 5V / div. A base de tempo 500s por diviso. O pulso de sada perfeitamente symmertic
em torno da rede cruzamento zero.
Mesmo enormes variaes de temperatura tm um efeito minsculo no pulso de cruzamento de zero, devido
natureza de "auto-polarizao" do circuito. A tolerncia de capacitncia de C1 no tem qualquer efeito. A
proporo entre as resistncia do circuito , principalmente no ponto de operao, a razo por que o pulso
de sada quase independente da temperatura.
A imagem direita uma resposta simulada por duas voltagens extremas (100VAC ... 240 VCA). Voc pode
ver que a variao de largura de pulso minscula, sendo menos de 100us sobre toda a faixa de tenso de
alimentao. Comportamento real no circuito real igual.

OTHER USES - LOAD MONITORING


Sometimes you don't need to monitor the mains itself, but you need to monitor a controlled mains load. Also here the ZC circuit come in handy. An example is shown in Fig 5. Here a triac controls an incadescent bulb either on or off. With the help of the ZC you can monitor a shorted load, an open load, missing live voltage, and also if the triac is working properly.
When the power to the load is switched off:
There is always a small leakage current via the triac snubber, even if the triac is off. This current is effectively shorted by the load, thus the ZCD sees no voltage and does not produce output pulses when the load is connected. If the load becomes disconnected or the bulb filament has failed, then the snubber leakage current is high enough to produce ZC-pulses even if the triac is off. This way you can check the contidion of the bulb without adding cumbersome current measurement circuits, and get a warning if the load has failed.
When the power to the load is switched on:
During this time the ZCD must produce pulses - if not - then the triac has failed or the live voltage is missing (possibly a blown fuse earlier in the circuit).
By combining ZCD information with the triac drive status, you will be able to detect failures in driving a load. Any mission critical loads (such as alarm lights, traffic lights) can benefit from load monitoring.

OUTROS USOS - MONITORAMENTO DA CARGA

s vezes voc no precisa monitorar a alimentao em si, mas preciso monitorar uma carga de
alimentao controlada. Tambm aqui o circuito de ZC vem a calhar. Um exemplo mostrado na Figura 5.
Aqui, um triac controla uma lmpada incandescente ou on ou off. Com a ajuda do ZC voc pode monitorar
uma carga em curto-circuito, uma carga aberta, faltando tenso viva, e tambm se o triac est funcionando
corretamente.
Quando a energia para a carga desligado:
Existe sempre uma pequena corrente de fuga atravs do amortecedor triac (snubber), mesmo se o triac
estiver desligado. Esta corrente efetivamente em curto-circuito para a carga, assim, a ZCD no v nenhuma
tenso e no produz impulsos de sada quando a carga ligada. Se a carga for desligada ou o filamento da
lmpada falhar, em seguida, a corrente de fuga do snubber suficientemente elevada para produzir ZCpulsos mesmo que o triac esteja desligado. Desta forma, voc pode verificar a condio do bulbo sem a
adio de pesados circuitos de medio de corrente, e receber um aviso que a carga falhou.
Quando a energia para a carga ligada:
Durante este tempo o ZCD deve produzir pulsos - se no - o triac falhou ou a tenso viva est ausente
(possivelmente um fusvel fundido no incio do circuito).
Ao combinar informaes ZCD com o status da unidade triac, voc ser capaz de detectar falhas na
conduo de uma carga. Quaisquer cargas de misso crtica (como luzes de alarme, semforos) podem se
beneficiar de monitoramento da carga.
NOTEWORTHY OBSERATIONS
This zero crossing detector takes a while to start because C1 must first be charged to its equilibrium voltage. This takes about 200 to 400ms, depending on the mains voltage. However, after this period the circuit works normally and reacts immediately to missing mains voltage cycles.
This ZCD can be used for other specific purposes, for example as a missing mains cycle detector, as a pulse-length discriminator, as a AC-load monitor, as a mains fuse condition detector, as an AC-motor function monitor, to mention a few.
Connecting the phase detector between the phases of a 1-phase motor will produce somewhat higher voltages than the mains, and you have to make sure that the combined voltage and power rating of R1 and R2 is high enough.

OBSERATIONS SIGNIFICATIVAS
Este detector de cruzamento de zero leva um tempo para iniciar porque C1 deve primeiro ser levado a sua
tenso de equilbrio. Isto leva cerca de 200 a 400 ms, dependendo da tenso de rede. No entanto, aps este
perodo, o circuito funciona normalmente e reage imediatamente ao zero dos ciclos de tenso.
Este ZCD pode ser utilizado para outros fins especficos, por exemplo, como um detector de falta de ciclos
na alimentao (cycle detector), como um discriminador de largura de impulsos (pulse-length
discriminator) , como um monitor de carga AC (AC-load monitor), como um detector da condio do fusvel
de rede (fuse condition detector), como um monitor de funo AC-motor (AC-motor function monitor) para
mencionar poucos.

Ligar o detector de fase entre as fases de um motor de 1-fase ir produzir tenses pouco maior do que a
corrente elctrica, e voc tem que se certificar de que a proporo da tenso nominal combinada com o
valores e potencias de R1 e R2 alta o suficiente.

Fig. 6 - AC-motor monitoring ciruit. The first ZC-detector determines the existence of the mains voltage and gives the microprocessor a reference zero crossing signal. The other ZC-circuit measures the phase difference (or it's zero crossing occurence). If the delay between the two ZC-circuits is within predetermined limits you can be sue of that the motor rotates.

Figo. 3 - monitoramento ciruit AC-motor. O primeiro ZC-detector determina a existncia da tenso da rede e
d ao microprocessador um sinal de cruzamento de zero de referncia. O outro ZC-circuito mede a diferena
de fase (ou seja cruzamento zero ocorrncia). Se houver atraso (delay ) entre os dois circuitos ZC dentro dos
limites predeterminados pode ser indicao de que o motor gira.
OTHER USES - AC MOTOR MONITORING
Running an 1-phase AC motor and knowing that the motor actually rotates can also easily be monitored by using two ZC detectors. This quite unique but simple idea using only two simple ZC detectors can actually monitor many types of failures, including; open or short circuits in any widning or wires to the motor, open or short circuits in the motor capacitor or its wires, relay, triac and fuse failures. Even a stalled rotor can be detected. Any of these failures will cause the motor not to rotate, and this condition can be sensed as explained.
You need a microprocessor to perform the logic, but the circuitry is othervice simple. To power the motor on or off, you can use the circuitry in Fig 2, and use Fig 3 as the load. It is recommended to use a triac to control the motor power, and a relay (preferably two) to control the direction of the motor (if needed). To prevent relay contact damage the relay(s) should change state only when the triac is off and the motor standing still.
The first ZC detector that is connected straight across the input (between L and N) monitors the incoming voltage (and thus also checks the proper triac operation and the availability of the mains voltage or blown fuses). The second ZC detector detects the zero crossing BETWEEN the motor phases. This ZC pulse is time delayed from the mains zero crossing by a certain amount of time and depends on the motor inductance and motor capacitance tolerance. On a 50Hz mains frequency the phase shift of typically 90 degrees would produce a delay of about 5ms. Both ZC signals should be connected to a microprocessor's input capture pins. By
teaching the microprocessor the time delay and it's allowed time variance, you can check with 100% certainty that the motor is rotating, even without any tachomerty feedback from its axle. Any failure mentioned above would either cause the pulses from the ZC detector (between the motor phases) to be missing completely, or the phase relationship referenced to the mains zero crossings to differ considerably. With the help of the microprocessor logic, you can thus build a rotation failure warning system for any mains operated 1-phase motor.

O primeiro detector ZC que est conectado diretamente na entrada (entre L e N) e monitora a tenso de
entrada (e, portanto, tambm verifica a operao adequada do triac e a disponibilidade da tenso da rede ou
fusveis fundidos). O segundo detector ZC detecta a passagem por zero entre as fases do motor. Este pulso
ZC hora atrasado da rede elctrica no cruzamento zero por um determinado perodo de tempo e depende da
tolerncia indutncia e capacitncia do motor . Em uma frequncia de 50Hz a mudana de fase de
tipicamente 90 graus produziria um atraso de cerca de 5ms. Ambos os sinais ZC devem ser conectados
entrada de captura dos pinos de um microprocessador. Ao ensinar ao microprocessador o tempo de atraso
que permitido na variao de tempo, voc poder verificar com 100% de certeza de que o motor est
girando, mesmo sem qualquer feedback tachomerty no seu eixo. Qualquer falha acima mencionada vai fazer
com que os impulsos do detector de ZC (entre as fases do motor) estar completamente ausente, ou a relao
de fase referenciada corrente nos cruzamentos de zero diferirem consideravelmente. Com a ajuda da
lgica de microprocessador, voc pode, portanto, construir um sistema de aviso de falha de rotao para
qualquer motor operando em 1-fase.
OUTROS USOS - monitorizao do motor AC
Num motor de corrente alternada de fase 1 saber se o motor gira, na verdade, pode tambm ser facilmente
monitorizado utilizando dois detectores ZC. Essa idia bastante original, mas simples, usando apenas dois
detectores ZC simples pode realmente monitorar muitos tipos de falhas, incluindo; circuitos abertos ou
curtos em qualquer widning ou fios do motor, circuitos abertos ou curtos no capacitor do motor ou de suas
falhas de fios, rel, triac e fusveis. Mesmo um rotor bloqueado pode ser detectado. Qualquer destas falhas
far com que o motor no gire, e esta condio pode ser detectada, tal como explicado.
Voc precisa de um microprocessador para executar o lgica, mas o circuito muito simples. Para alimentar
o motor ligado ou desligado, voc pode usar o circuito na figura 2, e utilizar figura 3 na carga.
recomendado usar um triac para controlar a potncia do motor, e um rel (de preferncia dois) para controlar
o sentido do motor (se necessrio). Para evitar danificar o contato do rel (s) deve-se mudar de estado
somente quando o triac est desligado e o motor parado.