CIRCUIT DRAWN WITH POWER SUPPLY OFF

4
U

3
PHASE
SUPPLY

3
6
5

T ap

FS1

C1

W
X
Y
Z

C2
W

RWS100
TR AN S F OR ME R TAP P IN G OP TION S

FOR TYPICAL REMOTE CONTROL


DETAILS, SEE DOCUMENT

Nominal 50/60Hz
TYP E 1
220/230
380/400
400,415/420
440/460

F US E F S 1= 250mA A NTI-S UR G E

PS1

120VAC 4

0VDC
3
24VDC 6

TRANSISTOR SWITCHING FOR


24VDC CONTACTORS (IQ10-35)
RELAYS ONLY FITTED WHEN
120VAC CONTACTOR IS FITTED
FOR IQ40,70,90,91 & 95

SK2
0VAC 1

SK14
0VDC 1
24VDC

24VDC
NOMINAL SUPPLY
(OUTPUT)

INTERNAL SUPPLY
FOR CPT PCB

W
X
Y
Z

TYP E 2
346/380
480/500
240/240
550/575

F US E F S 1= 250mA A NTI-S UR G E

X
Y

TYP E 3
660/660-690
690/-

F US E F S 1= 150mA A NTI-S UR G E

SK13

REFER TO SHEET 2 FOR NOTES


& OPTION PCB'S IF FITTED

26 WAY

SK13

SK3
6

TORQUE
SENSOR

MONITOR RELAY

4
3
2
1

SK8

POSITION
SENSOR

10 WAY

FS2 (IF FITTED) 100mA

MAKE AT FULLY SHUT

MAKE AT FULLY OPEN

BATTERY

SK14
1

SK9 BREAK AT FULLY SHUT


4
1

BREAK AT FULLY OPEN

S1
S2
S3
S4

18 WAY
STOP

CLOSE

LOCAL
OPEN

REMOTE

Iss Date Chkd


Revision Details
1 150115 JC1 FIRST ISSUE.

7
8
9
10
11

6
4

12
13

OPEN
COMMON -VE

ESD

12

OPEN INTERLOCK

13

CLOSE INTERLOCK

14

COMMON -VE

www.

SK1
SLOT A
SK1
SLOT C

44

33
34

10

STOP/ MAINTAIN
SK6

43

SK4
9

CLOSE

50%

SK7
1

42

35
36
25
37
38
31

SK2
SLOT B
SK2
SLOT D

.com

IQ + HART + CPT + INDICATION RELAYS S5 - S12

ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: PJW


Date
: 150115
BATH, BA1 3JQ
ROCHESTER
Base WD: 101H2020
ENGLAND
NY 14624, USA

Tel:01225-733200

Tel:585-247-2304

Job No : - MI No : - -

Circuit Diagram Number

101H2020
B1 C1 B2 C2 B1 C1M1V1 B1 C1M1V1

Issue
No

Sheet

1
of 2
IQ3

HART
(REFER TO
MANUAL
PUB092-003)

SLOT A

CIRCUIT DRAWN WITH POWER SUPPLY OFF


SK1
SLOT A

SK3
1

26 DEMAND +

27 DEMAND

29 SCREEN
32

SLOT B

SK2
SLOT B

E
SK3

+VE

22

CPT

-VE

23

FOR DETAILS OF CPT FUNCTIONS


REFER TO ROTORK PUBLICATION PUB002-041

SK6

0V
24V

1
2

SUPPLY FROM SK14 ON POWER PCB

SK8

1
2

DEFAULT SETTINGS SHOWN


FOR OTHER SETTINGS SEE PUB002-038

EXTRA CHANGE OVER CONTACTS

SLOT C

SK1
SLOT C

2
MAKE AT FULLY SHUT

DEFAULT SETTINGS SHOWN


FOR OTHER SETTINGS SEE PUB002-038

S5

14

16

1
5
MAKE AT FULLY OPEN S6

17
19

4
MAKE ON TORQUE
TRIP S7

20

24

7
MAKE WHEN REMOTE
SELECTED

30

11
S8

12

47

10

SLOT D
EXTRA RELAY CONTACTS

SK3

SK2
SLOT D

SK3

1
MAKE AT FULLY SHUT

S9

MAKE AT FULLY OPEN S10

MAKE ON TORQUE
TRIP S11

MAKE WHEN REMOTE


SELECTED S12

15

18

21

39

40

41

10

45

11

46

NOTES
1.FUSES:
-PS1 is a self-resetting fuse.
-Refer to publication PUB002-039 for approved fuses FS1 and FS2.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%,
applies for rated torque performance; duty cycle is not guaranteed.
2.REMOTE CONTROL:
-For typical remote control circuits refer to:
-RWS indicated or PUB002-041.
-For DC and AC control, connect ve/0V to terminal 36.
-(For negative switch / positive common, refer to RWS indicated).
-Control signal threshold voltages:
-DC: on 16Vdc / off 8Vdc, max 60Vdc.
-AC: on 60Vac / off 40Vac, max 120Vac.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is:
-8mA at 24Vdc or 12mA at 120Vac.
-Supply provided on terminals 4 & 5:
-Intended for remote control.
-Max external load 5W at 24Vdc / 5VA at 120Vac

3.INDICATION:
-For typical position, status and alarm indication see PUB002-041.
-S contacts are user configurable and are shown in their default
setting.
-Refer to PUB002-040 for functions and configuration instructions.
-Monitor Relay indicates actuator availability for remote control (shown
unavailable). It can be configured to exclude local/remote selection.
-Refer to PUB002-040 for monitored functions and configuration
instructions.
-Voltage applied to indication contacts must not exceed 150Vac
-Individual Switch current must not exceed 3.5A inductive, 5A resistive
and no more than 8A in total for all 4 contacts.
4.BATTERY:
-Battery maintains local and remote S contact indication only.
-Refer to installation manual for approved replacement battery types.

See Sheet 1 for all Revision details/information

Circuit Diagram Number

Issue
No

101H2020 1

Sheet

2
of 2