Uninterruptible (ATX)
Switching Power Supply
MODEL eUPS-350
PAGE: 1 OF 10
PAGE: 2 OF 10
TABLE OF CONTENTS
1. INTRODUCTION:................................................................................................................. 4
1.1.
1.2.
2. INPUT................................................................................................................................... 4
2.1.
2.2.
AC INPUT ................................................................................................................................. 4
DC INPUT ................................................................................................................................. 4
REGULATION .......................................................................................................................... 5
P-P NOISE (NOT TO EXCEED)............................................................................................... 5
OVER POWER PROTECTION ................................................................................................ 5
SHORT CIRCUIT PROTECTION............................................................................................. 5
OVER VOLTAGE PROTECTION FOR +5V; +12V; 3.3V......................................................... 5
PROTECTION FUNCTIONS .................................................................................................... 6
RISE TIME TURN ON DELAY NORMAL LOAD ...................................................................... 6
POWER GOOD SIGNAL .......................................................................................................... 6
TEMPERATURE RANGE......................................................................................................... 8
PAGE: 3 OF 10
HUMIDITY:................................................................................................................................ 8
ALTITUDE................................................................................................................................. 8
SAFETY .................................................................................................................................... 9
EMI............................................................................................................................................ 9
MEAN TIME BETWEEN FAILURE (MTBF) ............................................................................. 9
1.
PAGE: 4 OF 10
Introduction:
This specification defines electrical performance and characteristic of model
eUPS-350 designed base on Intel ATX 12V power supply design guide. This
model is approved by UL File Number E164858 (s)
1.1.
1.2.
236W
100W
14W
Software Overview:
The software interface is compliance with WIN 2000, XP and JAGER UPS
Monitor.
2.
INPUT
2.1.
2.1.1.
AC INPUT
FOR 120VAC LINE
Min.
Vin Range
100 115
Vin Frequency
47
Inrush Current (Max)
35
2.1.2.
Units.
140
67
Vrms
Hz
Apk
Max.
Units.
264
67
Vrms
Hz
Apk
Vin Range
180 230
Vin Frequency
47
Inrush Current (Max)
50
2.2.
Max.
DC INPUT
Min.
Vin Range
20
24
Max.
Units.
28
Vdc
3.
PAGE: 5 OF 10
+3.3V
+12V
-12V
-5V
+5VSB
20 (25)
14 (20)
8 (12)
0.5 (0.8)
0.5 (0.5)
1 (1.5)
100 (142 ) W
Watt
96(144)W
218W
monitor
+28Vchrg
0.5
(60-100w)
1.5W
9.6W
7.5W
14W
3.1.
Regulation
+5V
+3.3V
12V
-5V
-12V
+5V SB
3.2.
3.3.
Min
4.75
3.10
11.40
-4.75
-10.80
4.75
Nom
5.00
3.30
12.00
-5.00
-12.00
5.00
Max
5.25
3.46
12.60
-5.25
-13.20
5.25
Unit
V
V
V
V
V
V
+12V
-5V
-12V
50mV
120mV
100mV
120mV
+5V SB
50 mV
+3.3V
50mV
3.4.
3.5.
3.6.
3.7.
Protection Functions
3.8.
4.
4.1.
150ms - 500ms
4.2.
Charging Current
Max Charging Current: 0.5A
5.
5.1.
5.2.
On backup mode:
130Vdc ~ 230Vdc @ 0.5A
5.3.
PAGE: 6 OF 10
6.
PAGE: 7 OF 10
7.
Battery
The one set of battery kit consists of two maintenance free sealed lead acid
(12V/ 2.5 Ah) batteries connecting in series. Other types of batteries such as
Car Batteries can also be used. The backup time is proportional to the
capacity of the battery.
Note: The battery kit is NOT an internal part of the eUPS-350 and is sold
separately.
7.1.
7.2.
7.3.
7.4.
7.5.
Charging Current
0.004A 0.5A
7.6.
Leakage Current
Less then or equal to 0.1 mA
7.7.
Recharge time
8 hours at room temperature (25) to replenish 50% charge. > 16 hours at
room temperature (25) to replenish 90% charge.
7.8.
PAGE: 8 OF 10
8.
Transfer Time
Backup Transfer Time: 0 ms for Vdc out to PC Main unit.
Transfer time for AC loading (Monitor) when AC fail: Typically under 8 ~
18ms.
9.
10.
Environmental
The eUPS-350 is capable of withstanding the following:
10.1.
Temperature range
Operating: ............. 10 to 45
Storage: ................ -20 to 55
Storage Duration:
Max 6 months with battery (battery needs to be
recharged if stored over 6 months).
When the battery is operated in temperatures lower than or equal to 10,
the back up time will be shorter than when it is operating at 20.
10.2.
Humidity:
Operating: ..............85% non-condensing
Storage: .................95% non-condensing
10.3.
Altitude
Operating: ..............Up to 2000 meters (max)
Storage: .................Up to 4000 meters (max)
11.
11.1.
PAGE: 9 OF 10
11.2.
EMI
FCC part class B (DOC)
11.3.
12.
12.1.
ISOLATION
Isolation impedance
Between AC Input and DC Output: 50 Mega ohms
Between Virtual AC Output for monitor and Battery: 50 Mega ohms
12.2.
Isolation voltage:
Between AC Input and Grounding: ......................1500Vac for 1 Min.
Between AC Input and DC Outputs: ..................4250Vdc for 1 Min.
Between Monitor AC output and Battery:.............4250Vdc for 1 Min.
13.
13.1.
MECHANICAL
Dimensions and Wiring
Standard P/S II dimension and output wiring of ATX connectors.
13.2.
PAGE: 10 OF 10
AC Input / Output
At the rear of the eUPS-350: 2 CEE-22 sockets.
14.
15.
16.
TECHNICAL REVISIONS
The appearance of products, including safety agency certifications pictured
on labels, may change depending on the date manufactured. Specifications
are subject to change without notice.