ASSESSMENT SCHEME
FOR THE ENVIRONNEMENTAL
PERFORMANCE OF BUILDINGS
Assessment scheme for the environmental
performance of buildings
Certification AQUA-HQETM
NON-RESIDENTIAL BUILDINGS
www.aqua-hqe.com.br
WARNING
This document forms part of the construction project certification scheme for non-residential buildings,
applicable to Brasil.
This Assessment Scheme for the Environmental Performance of Buildings Non-residential buildings
version March 2014, developed by Cerway, and adapted to Brazil by Fundao Vanzolini, is protected by
copyright.
The following copyright symbol features on all pages of this scheme:
2 /139
ACKNOWLEDGEMENTS
The following people contributed to writing this scheme:
Contributors
ARQUI
AURIAULT
BARBIER
BARGE
BART
BEAUR
BELHOMME
BOIREAU
BONNET
BONNIFET
BUGNON
CALVEZ
CARDONA
CHARLES
CHARVET
CLAIR
CLERAUX
COUZENS
CREPIN
CUNHA
DANIEL
DELAMARE
DESBARRIERES
DEVELEY
DIEULESAINT
DUBROCA
DUMAS
FAHY
FLORIO
GALINAT
GAROT
GEORGES
HAVARD
HOVORKA
JARRY
KARSENTY
KAUFMAN
KERTEZS
LAIR
LANDRY
LANQUETUIT
LEBAUT
LECONTE
LEFEVRE
LESOMMER
LESTOURNELLE
MATHIEU
MELAY
MESUREUR
MOUILLOT
NGUYEN
OUDOT
PARANT
PARTOS
PERINO
PERISSIN
Olivier
Jean-Pierre
Christelle
Olivier
Maris
Christian
Gaulthier
Lucie
Claire
Fabrice
Matthieu
Gal
Kevin
Nathalie
Thomas
Chlo
Aurlie
Rebecca
Laurent
Ana
Xavier
Thierry
Antoine
Catherine
Yves
Maria
Elodie
Pierre
Flix
Vivianne
Christophe
Latitia
Michel
Frank
Olivier
Jean Pierre
Daniel
Christine
Ingrid
Olivier
Maxime
Benjamin
Frdric
Thomas
Michel
Carole
Christophe
Blandine
Bruno
Jean-Pierre
Liem
Anne-Claire
Catherine
Jrme
Matto
Anne Sophie
ALTO INGENIERIE
BNP PARIBAS
ELAN
GENERAL ELECTRIC
ALDES
CBRE
OGER INTERNATIONAL
ELAN
ELAN
BOUYGUES
IOSIS GROUP
BNP PARIS REAL ESTATE
UNIBAIL
EDF
BNP REAL ESTATE
BOUYGUES CONSTRUCTION
ELAN
ELAN
GENERALI IMMOBILIER
QUALITEL
CERQUAL
EDF
QUALITEL
ARCH SARL
GECINA
NOBATEK
ALTO INGENIERIE
DECATHLON
FELIX FLORIO CONSULTANTS
ACCOR
UNIBAIL
CBRE
ASSOCIATION HQE
CAISSE DES DEPOTS
GREEN AFFAIR
BOUYGUES IMMOBILIER
2DKS
AFNOR
ELAN
GENERAL ELECTRIC
ALTAREA COGEDIM
CBRE
ADA
HOARE LEA
LESOMMER ENVIRONNEMENT
AIMCC
GREEN AFFAIR
IOSIS GROUP
CSTB
ALTO INGENIERIE
BUREAU VERITAS
BGL BNP PARIBAS
SPACE ENVIRONMENT
EET
COGEDIM
ASSOCIATION HQE
3 /139
PETITPAS
PONTHIER
POTIER
QUIRKE
RABUT
RAOUST
RAYNAUD
SAINT-DONAT
SANSON
SAUBIAT
SCHMIDT
SIGDA
STECKELOROM
SUTTER
TROADEC
TURCAS
VAISSIERE
WILDGRUBER
Pierre
Patrick
Alexandre
Anne-Marie
Philippe
Michel
Pierre
Magali
Benoit
Cdric
Alexander
Mickal
Patrick
Yannick
Pierre
Guillaume
Jean Marie
Christoph
BOUYGUES
AIMCC
ALIAXIS
TERAO
AFNOR
TERAO
ALTO INGENIERIE
EDF OPTIMAL SOLUTION
WILMOTTE UK
VINCI CONSTRUCTION
PIERRE & VACANCES
BUREAU VERITAS
ALLIANZ
LESOMMER ENVIRONNEMENT
AIMCC
CBRE
AIMCC
ALLIANZ
4 /139
SUMMARY
TARGET ASSESSMENT
10
1.
1.1.
1.2.
1.3.
2.
2.1.
2.2.
2.3.
2.4.
Construction choices for the sustainability and adaptability of the building ..............................23
Construction choices to facilitate maintenance of the building ..................................................26
Choosing construction products in order to limit the socio-environmental impact of the building 27
Choosing construction products in order to limit the health-related impact .............................30
3.
3.1.
3.2.
3.3.
3.4.
4.
4.1.
4.2.
4.3.
5.
5.1.
5.2.
5.3.
6.
6.1.
6.2.
7.
7.1.
7.2.
7.3.
Optimising the design of the building for simplified maintenance and servicing of the construction's systems
63
Design of the building for the monitoring and control of energy consumption .........................65
Designing the building for the monitoring and control of system performance and comfort conditions
67
8.
8.1.
8.2.
8.3.
8.4.
5 /139
73
9.
9.1.
Creating an acoustic environment quality appropriate for the various rooms ...........................78
10.
14.1.
14.2.
14.3.
14.4.
135
6 /139
Target Assessment
For each technical criterion evaluated in each of the 14 targets, four performance levels are determined:
- HP: High performing;
- P: Performing;
- PR: Prerequisite
The Applicant must assess, or have assessed, each of the technical criteria specified in the 14 HQE targets
in order to manage the environmental performance profile of the building at the earliest possible stage.
TP
3 targets
4 targets
7 targets
7 /139
8 /139
9 /139
Part I:
Targets of environmental
performance of buildings
10 /139
1. THE BUILDING'S
RELATIONSHIP WITH ITS
IMMEDIATE ENVIRONMENT
FOREWORD
The assessment of target 1: "Relationship of the Building with its Immediate Environment" is conducted in
close relation to the details arising from the site analysis as required in the Project Environmental
Management Requirements Reference System (MEP).
Please note the following points:
The options for treating concerns depend on the site analysis, the project's restrictions, and the
applicant's major goals.
Sub-target 1.2: this sub-target does not apply to projects with no outside spaces.
Sub-target 1.3: the term "neighbourhood" designates all existing buildings including those on
the site in question. Sub-target 1.3 does not apply to projects with no nearby neighbourhood. Finally,
sub-target 1.3 also applies to the buildings of a single site if that site has a large footprint, which
requires consideration for internal urban development.
STRUCTURE OF TARGET 1
1.1 PLANNING THE PLOT FOR SUSTAINABLE URBAN DEVELOPMENT
1.2 QUALITY OF OUTDOOR SPACES ACCESSIBLE FOR USERS
1.3 IMPACTS OF THE BUILDING ON THE NEIGHBOURHOOD
11 /139
ASSESSMENT OF TARGET 1
ASSESSMENT
TARGET 1
PR
PERFORMING
HIGH
PERFORMING
Number of points to
obtain (if all points
are applicable) to
achieve level :
Spaces / Sub-targets
1.1
1.2
1.3
Totals
HP
NON RESIDENTIAL
BUILDING
52
20
19
91
46
69
LOGISTIC PLATFORM
48
20
26
94
47
71
SHIPPING DOCK
48
20
26
94
47
71
REFRIGERATED
WAREHOUSE
48
22
26
96
48
72
RETAIL / STATION /
AIRPORT TERMINAL
54
20
19
93
47
70
EXHIBITION HALL
45
20
26
91
46
69
12 /139
Points
achieved
1.1.1. Ensure consistency between the layout of the plot and the community's policy
Consistency with the local land use policy and the area's sustainable development policy:
Proof according to the project that sustainable urban development issues have been taken into
account, in particular the limited use of locally available resources or utilities (energy, renewable
energy, water and sewerage), in order to minimize new constraints (waste, infrastructure
maintenance and services).
PR
Measures are taken to ensure the physical separation of pedestrian and bicycle access from other
flows.
13 /139
Assessment criterion
Points
achieved
2 lines
3 lines or more
Additional points:
Number of lines accessible within 200 m:
1 line
2 lines
3 lines or more
Of 3 to 4 lines
5 lines or more
For logistics hubs / loading bay / refrigerated warehouse / exhibition hall operations:
Project located within 600 m of a public transport stop.
14 /139
Assessment criterion
Points
achieved
1.1.4. Control travel methods and encourage those which are the least polluting for
optimal functionality
All modes of transport
A special study is conducted with the aim of optimising the number of parking spaces with
regard to the project background.
Comprehensive urban mobility study ahead of the project.
Encourage the use of clean vehicles
A parking area is reserved for clean vehicles (including electric vehicles) equipped with
devices to encourage their use, representing at least 10% of all parking spaces (light vehicles)
Encourage the use of walking and cycling
Establishment of a space reserved for the secure parking of bicycles for personnel.
The bike parking spaces are designed with respect for flow estimates (for all users) (personnel
at a minimum).
AND presence of appropriate communal facilities (changing rooms, showers) for personnel
using bicycles.
PR
5
1
2
4
Additional point:
The bike parking spaces, correctly designed as indicated above, are sheltered (rooms, roofs).
PR
Additional points:
Design of a rail-connected multimodal hub,
Design of a quayside multimodal hub.
1
1
15 /139
Assessment criterion
Points
achieved
Facades: There is a planted vertical surface representing at least 10% of the total area of the
facades.
Design of at least 50% of the parking lot surface area for light vehicles to be planted.
Based on the report written up: Realization of a specific study to justify the species planted with a
view to improving biodiversity and reconstructing the habitat and living conditions of the fauna on the
plot.
16 /139
1.2.
Points
achieved
Proven and satisfactory architectural and/or technical measures are taken to limit sound nuisance on
the plot's outdoor spaces.
17 /139
Assessment criterion
Points
achieved
1.2.4. Ensure the right to sanitary quality of the spaces for users on the plot
Layout of the plot taking into account the risks of olfactory pollution or nuisances on outdoor
spaces.
Choice of plant species with the aim of minimizing the health impact on the plot by minimizing
allergenic and toxic species.
Realization of a specific study on the landscaping of the project and the impact of the allergenic
potential of the species planted.
18 /139
1.3.
Points
achieved
1.3.1. Ensure the local residents' right to sun and natural light
Realization of a specific study with the aim of identifying the local residents right to sun and natural
light with regard to the status quo.
AND
Measures are taken to optimise this right, particularly by working on the sunshine duration and on the
masking effects that the construction of the project has on neighbouring buildings.
1
3
1.3.4. Ensure the right to sanitary quality of the spaces for local residents
Layout of the plot taking into account the risks of pollution or olfactory nuisances for the local
residents.
Choice of plant species with the aim of minimizing the health impact for the locals by minimizing
allergenic and toxic species.
Realization of a specific study on the landscaping of the project and the impact of the allergenic
potential of the species planted for the local residents.
19 /139
Assessment criterion
Points
achieved
Measures are taken so that the lighting for the site's sign-posting does not cause visual nuisance to
the local residents at night.
Providing services to the site may not cause heavy vehicles to travel near residences located less
than:
Near residences located less than 100m from the road
20 /139
2. ADAPTABILITY OF THE
BUILDING AND
INTEGRATED CHOICES OF
CONSTRUCTION
PRODUCTS, SYSTEMS
AND PROCESSES
STRUCTURE OF TARGET 2
2.1 CONSTRUCTION CHOICES FOR THE SUSTAINABILITY AND ADAPTABILITY OF THE BUILDING
2.2 CONSTRUCTION CHOICES TO FACILITATE MAINTENANCE OF THE BUILDING
2.3 CHOOSING CONSTRUCTION PRODUCTS IN ORDER TO LIMIT THE SOCIO-ENVIRONMENTAL IMPACT OF THE
BUILDING
2.4 CHOOSING CONSTRUCTION PRODUCTS IN ORDER TO LIMIT THE HEALTH-RELATED IMPACT OF THE BUILDING
21 /139
ASSESSMENT OF TARGET 2
TARGET 2
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Spaces / Sub-targets
2.1
2.2
2.3
2.4
Totals
HP
NON-RESIDENTIAL
BUILDING(OTHER THAN THOSE
LISTED BELOW)
19
18
14
58
20
35
LOGISTIC PLATFORM,
SHIPPING DOCK,
REFRIGERATED WAREHOUSE,
AND EXHIBITION HALL
19
18
42
15
26
22 /139
2.1.1. Choose products, systems or processes whose characteristics are verified and
compatible with the usage
The applicant uses products, systems or processes whose usability characteristics have been
assessed and verified, in any fields in which they exist and under conditions enabling objective
competition.
The products chosen must be compatible with the use of the building and of each area or room.
Choice of building products, systems and process from companies that participate and comply with
thePSQ - Programa Setorial da Qualidade (PSQ - Sectorial Quality Programme) corresponding to their
scope of practice in the SiMaC (Sistema de Qualificao de Empresas de Materiais, Componentes e
Sistemas Construtivos Qualification System of Materials, Components and Construction Systems
Companies) programme of PBQP-H(Programa Brasileiro de Qualidade e Produtividade do Habitat
Brazilian Programme of Habitat Quality and Productivity) or
a) technical assessment by SINAT (Sistema Nacional de Avaliao Tcnica National System of
Technical Assessment) of the PBQP-H
b) certification in accordance with one of the modalities of products certification defined by Inmetro Instituto Nacional of Metrologia, Normalizao and Qualidade Industrial (Inmetro - National Institute
of Metrology, Normalization and Industrial Quality) (Model 1 to model 8 (except the model 6) in
accordance with NBR ISO/IEC Guide 65:1997)
c) To perform tests in accredited laboratory
When there is no corresponding PSQ and it is no possible meeting of at least one of the above
requirements (a, b and c):
d) product inspection-warranty on receipt by means of a management system of the construction
company that will use it, in order to refuse non-complying products, in accordance with pre-set
requirements.
Compliance of the products of each one of the following construction products, systems and processes
families:
foundations
rooftops
floor coverings
23 /139
Points
achieved
Assessment criterion
Points
achieved
building installations
ABCP (Associao Brasileira de Cimento Portland Portland Brazilian Association of Cement) quality
seals can be considered as compliance indicators for cements and concrete blocks.
PR
2.1.2. Adaptability of the building over time based on its forecast lifespan and usages
Consideration given to the adaptability of the building.
Definition
of
the
building's
forecast
lifespan.
Booklet containing classification of zones according to expected adaptation: frequently adapted,
occasionally adapted or not intended for adaptation.
PR
For frequently and occasionally adapted zones, technical measures taken to facilitate their adaptation
(systems, light work, structure).
Considerations and measures are taken to envisage a change or development in the use of the building
(structure, networks).
24 /139
Assessment criterion
Points
achieved
Building envelope
More than 50% (in surface area)
Building structure
Construction processes enable maximum separation of the products with a view to optimal
environmental management of their end of life
25 /139
2.2.
Construction choices to facilitate maintenance of the
building
Assessment criterion
Points
achieved
2.2.1. Choosing construction products, systems and processes which are easy to
maintain and limit the environmental impact of maintenance
Establishment of the list of products necessary to maintaining the internal floor coverings products.
Choice of construction products which are easy to maintain and limit the environmental impacts of
maintenance (energy (kWh/sqm) or CO2 (keqCO2/sqm)or water (m3/sqm) or waste (kg/sqm)):
For indoor coverings (floors, walls and ceilings), based on the expected frequency of
maintenance.
For indoor coverings (floors, walls and ceilings) AND for at least 50% of the surface area of
two of the four categories below:
26 /139
2.3.
Choosing construction products in order to limit the
socio-environmental impact of the building
Assessment criterion
Points
achieved
For at least 50% of the components in at least four categories of finishing products AND two
categories of structural and/or road products
For at least 80% of the components in at least four categories of finishing products AND two
categories of structural and/or road products
For at least 50% of the components in at least four categories of finishing products AND two
categories of structural and/or road products
2.3.2. Choose construction products to limit the environmental impact of the building
Known traceability of the origin of natural resources employed (sand, crushed stone, stones, etc.).
Use of cement CP III or CP IV in the project, even in cast-in-place concrete, according to locally
available cement types and to the analysis of technical and economic feasibility
PR
Choices must be based in studies conducted in 2.3.1, in accordance with the Product Information
Sheets and EPDs
For the structure OR for the finishing:
27 /139
Assessment criterion
Use of cement CP III or CP IV in the project, even in machined concrete and in premolded composed
by these cements, according to locally available cement types.
Points
achieved
2.3.3. Use materials and products enabling the least polluting site procurement in
terms of CO2
At least for the products studied in 2.3.1:
Definition of a transport strategy for the materials and products from the production, processing or
extraction site to the worksite, giving priority to the least polluting supply lines, enabling CO2 emissions
to be limited.
28 /139
Assessment criterion
Points
achieved
2.3.5. Choose product manufacturers and service providers that do not practice
informality in the production chain
Choice, for the following families, of product manufacturers that do not practice tax informality, and of
service providers that do not practice tax and labour informality:
foundations
subfloor
building systems
painting
PR
29 /139
2.4.
Choosing construction products in order to limit the
health-related impact
*IMPORTANT: The storage rooms of logistics platforms, shipping docks and refrigerated warehouses as
well as the halls of exhibition buildings are not concerned by sub-target 2.4.
Assessment criterion
Points
achieved
AND
For 100% of the surface coverings, compliance with the conditions of Appendix II Table A Phase II of
directive
2010/79/EU
AND
Determination of the emissions of TVOC and formaldehyde for at least:
50%
80%
100%
of the products in direct contact with indoor air (in surface area).
30 /139
1
2
4
Assessment criterion
Points
achieved
2
4
Formaldehyde:
< 60 g/m3
< 10 g/m3
2
4
31 /139
PR
3. LOW ENVIRONMENTAL
IMPACT WORKSITE
3
STRUCTURE OF TARGET 3
3.1. OPTIMISING THE WORKSITE'S WASTE MANAGEMENT
3.2 LIMITING NUISANCES AND POLLUTION ON THE WORKSITE
3.3 LIMITING THE CONSUMPTION OF RESOURCES ON THE WORKSITE
32 /139
ASSESSMENT OF TARGET 3
ASSESSMENT
TARGET 3
PR
PERFORMING
HIGH
PERFORMING
Number of
points to obtain
(if all points are
applicable) to
achieve level :
Sub-targets
3.1
3.2
3.3
3.4
Totals
HP
NON-RESIDENTIAL
BUILDINGS
21
13
44
15
26
33 /139
Points
achieved
Class A waste: concrete, concrete blocks, ceramic blocks, mortars, other ceramic components,
bricks and the like, etc.
Class D waste: asbestos, tools and packaging contaminated by hazardous waste, paints,
solvents, etc.
AND
Estimate of the quantities produced for each type of waste.
AND
Throughout the construction, measures taken during construction and any pre-dismantling to
determine and monitor the quantities produced (in kg or in L) for each type of waste.
PR
Measures taken with regard to construction techniques to limit the production of waste at source.
Proven, satisfactory measures.
34 /139
Assessment criterion
Points
achieved
3.1.3. Recycle the worksite's waste as well as possible , as appropriate for the
existing local recycling channels, and ascertain the appropriate destination of
the waste
Measures taken to know the total mass of worksites waste and, therefore, estimate the percentage of
recycling.
Controlled waste
Compliance with regulatory requirements to controlled waste disposal, which means:
For each type of hazardous waste, chose a disposal company compliant with applicable
regulation;
For packaging waste whose production is greater than 1100 liters/week, benefit 100% of the
waste under the form of re-use, recycling or other forms of recycling that turn it into reusable
materials or energy sources.
AND
Recuperation of 100% of the tracking slips of waste transportation, for controlled waste.
Formal records of the processes of selection and assessment of 100% of the carriers and of the final
destinations.
PR
1
Non-controlled waste
Selection, for each waste category, of the more appropriate carrier and destination, from the technical,
environmental and economic points of view, prioritizing, as much as possible, the waste beneficiation
or recycling.
AND
Recuperation of 100% of the tracking slips of waste transportation, for non-controlled waste, in both
construction and deconstruction.
PR
Formal records of the processes of selection and assessment of 100% of the carriers and of the final
destinations.
PR
35 /139
Assessment criterion
Points
achieved
20%
50%
70%
3.1.4. Optimise the collection, sorting and grouping of the worksite's waste
Adoption of management and worksite organization measures to minimise the mass of generated
waste.
PR
Contractual arrangements made with respect to suppliers to minimise the mass of worksites waste.
Justified and satisfactory measures.
1
Based on the site analysis, realization of a worksite waste management plan specifying:
How each type of waste is collected and sorted,
The level of detail practiced in sorting types of waste, based on the space available and
downstream collection channels.
AND
Ensuring the worksites waste management plan is followed and respected during construction
36 /139
3.2.
Points
achieved
Additional points
Monitoring the noise levels and/or vibrations using a specific device, in accordance with the monitoring
protocol most appropriate to the background and in relation to the established schedule
AND
Corrective measures taken where necessary.
3.2.2. Limit visual nuisances and optimise the cleanliness of the worksite
Realization of weekly cleaning of the worksite and its peripheries
AND
Compliance with municipal health recommendations, if any
PR
Measures are taken to limit visual nuisances owing to the worksite and to guarantee its cleanliness.
Proven, satisfactory measures.
PR
2
37 /139
Assessment criterion
Points
achieved
3.2.4. Avoid air pollution and control the health-related impact on the air
Compliance with regulatory requirements to limit air pollution, especially related to ban on burning and
to safety requirements for some products.
PR
Measures are taken regarding construction techniques and/or of an organizational nature to limit air
pollution and the release of dust. Proven, satisfactory measures.
38 /139
3.3.
Points
achieved
39 /139
3.4.
Points
achieved
PR
PR
Ensure the fiscal and labour formality of 100% of construction company (ies) subcontractors.
Ensure the fiscal and labour formality of 100% of the other service providers involved in activities on
the worksite.
40 /139
4. ENERGY MANAGEMENT
4
STRUCTURE OF TARGET 4
4.1. REDUCING ENERGY USE THROUGH ARCHITECTURAL DESIGN
4.2. REDUCING PRIMARY ENERGY CONSUMPTION
4.3. REDUCING THE EMISSION OF POLLUTANTS INTO THE ATMOSPHERE
41 /139
ASSESSMENT OF TARGET 4
TARGET 4
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Number of points to
obtain (if all points
are applicable) to
achieve level :
Spaces / Sub-targets
4.1
4.2
4.3
Totals
HP
NON-RESIDENTIAL
BUILDINGS OTHER
THANREFRIGERATED
WAREHOUSES
38
52
16
26
REFRIGERATED
WAREHOUSES
10
38
11
58
16
30
42 /139
Assesment criterion
4.1.1. Improve the ability of the building to reduce its energy demand
Justify the buildings bioclimatic design by means of:
An explanatory leaflet on the design of the project (volumetrics, ground plan, orientation of the
glazed surfaces and bioclimatic components) according to the background and activity in the
rooms, or achievement of C level in numeric equivalents of the envelope, in accordance with
RTQ-C (Quality Technical Requirements for the Energy Efficiency Level of Commercial,
Services and Public Buildings) regulation published by Inmetro/Procel (Programa Nacional de
Conservao de Energia Eltrica National Programme for Electric Energy Conservation)
A reduction in energy demand (Dheating, Dcold, Dlighting) calculated using a Dynamic
Simulation Model.
PR
1
An expression of the air permeability index target value by means of a measurement made in
accordance with standard ISO 9972 [A]
Realization of an air permeability measurement of the building in accordance with standard ISO 9972
AND
The result of the measurement, Q4Pa_surf, is less than or equal to the values below:
Sector
1.7
Other uses
3.0
43 /139
Assesment criterion
Points
achieved
4.1.3. Improve the ability of refrigerated warehouse envelopes to limit heat loss
For refrigerated warehouses with a positive controlled temperature
Expression of the Uaverage coefficient for the roof and vertical walls (average value weighted by the
surfaces of the basic Uwall coefficients , calculated in accordance with the Thermal Regulation in force
(W/m.K))
Uaverage< 0.24 W/mK
With a possible variation in absolute value of the basic Uwall by 10% in relation to Uaverage.
For refrigerated warehouses with a negative controlled temperature
Expression of the Uaverage coefficient for the roof and vertical walls (average value weighted by the
surfaces of the basic Uwall coefficients, calculated in accordance with the Thermal Regulatory Rules
in force (W/m.K))
Uaverage< 0.13 W/mK
With a possible variation in absolute value of the basic Uwall by 10% in relation to Uaverage.
Sectional doors opening onto a non-cooled space must respect standards in force and prove to have
the following heat transmission values:
Udoor<0.6W/mK
Udoor<0.35W/mK
44 /139
4.2.
Points
achieved
4.2.1. Reduce primary energy consumption due to heating, cooling, lighting, Service
Water Heating, ventilation and ancillary systems linked to user comfort
Provision of an energy booklet justifying the construction principles and equipment implemented
AND
Proof of a 10% saving compared with a reference level of consumption (1) using a Dynamic Simulation
Model on the building services below only:
PR
Heating
Cooling
Service Water Heating
Ventilation for heating, cooling and ventilation
Distribution and generation ancillary systems for heating, cooling and service water
heating
Artificial lighting (2)
Assessment of the building's energy performance:
20% savings
30% savings
40% savings
50% savings
60% savings
70% savings
80% savings
Positive energy building
5
6
7
8
6
10
15
20
45 /139
1
1
2
2
2
Assessment criterion
Points
achieved
The measures taken concern the power and/or management of artificial lighting
Limits for spaces lighting. Absolute lighting power densities (DPIA) limits must comply with RTQ-C of
Inmetro (Tables 4.1 or 4.2 of RTQ-C):
Level C
Level B
Level A
PR
1
2
(1) The calculation methodology and the definition of the reference values must comply with the
practical guide.
(2) This building service must take into account all types of artificial lighting with the exclusion of those
cited in 4.2.2.
46 /139
Assesment criterion
Points
achieved
PR
20%
30%
40%
PR
Level B
Level A
(1) The items to include in this study are specified in the guide.
47 /139
4.3.
Points
achieved
PR
Proof that the choice of energy (calculation of the quantities of CO 2 (eq-CO2) produced for different
energy alternatives) corresponds to the best possible compromise with respect to these CO 2 emissions
and the project owner's environmental goals.
Reduction in the quantity of CO2 emissions compared with reference (1) CO2 equivalent emissions
produced due to energy use by fixed building services, proving a saving of:
10%
20%
30%
Proof that the choice of energy (study of several energy alternatives) corresponds to the best possible
compromise with respect to these SO2 emissions and the project owner's environmental goals.
4.3.4. Choose the refrigerant for the refrigerated warehouse facilities to limit its
contribution to the environmental impacts
Expression of the global warming potential IGWP (kg eq CO2/kW) value of the facility
Performance achieved:
Warehouses with a positive or negative controlled temperature:
IGWP< 750
IGWP< 10
(1) Reference CO2 equivalent emissions are calculated in accordance with the reference Dynamic
Simulation Model (DSM) used in 4.2.1.
48 /139
5. WATER MANAGEMENT
5
STRUCTURE OF TARGET 5
5.1 REDUCING DISTRIBUTED DRINKING WATER CONSUMPTION
5.2 RAINWATER MANAGEMENT
5.3 WASTEWATER MANAGEMENT
49 /139
ASSESSMENT OF TARGET 5
TARGET 5
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Number of points to
obtain (if all points
are applicable) to
achieve level :
Sub-targets
5.1
5.2
5.3
Totals
HP
NON-RESIDENTIAL
BUILDINGS
12
16
12
40
12
50 /139
Points
achieved
PR
Other activities
D sanitary D ref., sanitary**
PR
51 /139
PR
Assesment criterion
Points
achieved
With regard to water demands that do not require the use of distributed drinking water (cisterns, urinals,
cleaning, watering and others), determination of the percentage of coverage of all of these demands
by from another source on-drinking water
AND performance achieved:
10%
25%
50%
Proof of this performance level by means of a gain and demand in terms of water report for nondrinking water on a daily step basis, modelling the daily behaviour of the water storage system and the
demand coverage.
5.1.4. Determine the overall consumption of total and distributed drinking and nondrinking water
Determination (or estimation) of the forecast consumption:
Total water consumed by the building in m 3/year and m3/FU/year*
Distributed Drinking water consumed by the building in m 3/year and m3/FU/year*
* The Functional Unit (FU) is m by default (see definition)
52 /139
PR
5.2.
Points
achieved
PR
Cimp 65%
PR
Realization of a feasibility study considering the infiltration on the plot and if the study concludes
that infiltration is relevant, implementation of infiltration techniques to infiltrate part of the stored
rainwater.
The rainwater storage volume on the plot is realized using alternative techniques for:
40%
60%
Pre-treatment of rains occurring strictly greater more often than the standard occurrence.
AND
Transmission to the operator of a half-yearly maintenance booklet.
53 /139
5.3.
Wastewater management
Assesment criterion
Points
achieved
PR
In the study, investigate various wastewater treatment scenarios, covering feasibility from a
technical, economic, environmental and health-related perspective.
Technical measures are taken to treat wastewater in order to satisfy the wastewater discharge
threshold values below:
Biological Oxygen Demand, BOD5: 35mg/L
Suspended Matter, SM: 30mg/L
Collective sanitation
Realization of a feasibility study on the installation of an innovative treatment system to treat
wastewater
on-site.
AND
If the study has shown an environmental advantage over being connected to the public network, ensure
on-site wastewater treatment by means of an innovative alternative sanitation system designed in
compliance with the country regulations, satisfying regulatory discharge standards, if any, and
minimizing potential nuisances (olfactory, visual or auditory) caused to users and local residents.
54 /139
Assesment criterion
Points
achieved
5.3.3. If the project is in a combined sewer network, limit rainwater discharges into
the network
Collective sanitation - combined sewer network
According to the plots imperviousness (calculation conducted in 5.2.1) and the rainwater recycling
possibilities, determine the annual percentage of rainwater not discharged into the network
AND performance achieved:
20%
40%
60%
Proof of this performance level by means of a gain and demand report for non-drinking water rainwater
on a daily step basis, taking into account any possible water recycling and modelling the daily
behaviour of rainwater discharges.
55 /139
6. OPERATIONAL WASTE
MANAGEMENT
6
STRUCTURE OF TARGET 6
6.1. Optimising the recycling of operational waste
6.2. Quality of the activity operational waste management system
56 /139
ASSESSMENT OF TARGET 6
TARGET 6
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
IMPORTANT: In the absence of local waste recycling channels, the target cannot be assessed as
PERFORMING or HIGH PERFORMING.
Sub-targets
NON-RESIDENTIAL
BUILDINGS
Number of points to
obtain (if all points
are applicable) to
achieve level :
6.1
6.2
Totals
HP
15
57 /139
Points
achieved
PR
Identification, for each class of waste:
Estimate of the disposal costs for each class of waste non-recovered in the buildings itself;
AND
Choice of the most satisfactory alternative for collection and destination of each class of waste, from
an environmental, technical and economic point of view, prioritizing as much as possible its recycling.
1
Recommend or choose* the most satisfactory disposal channel from a technical, economic and
environmental viewpoint, opting for a recycling channel (in terms of mass or volume):
For at least 50% of waste
58 /139
Assesment criterion
Points
achieved
* If it is too early to choose disposal channels (to be proven), draft prescriptions in the maintenance
notebook (see MEP appendix A.5) and/or the "user" specifications (see MEP appendix A.7)
59 /139
6.2.
Quality of the activity operational waste management
system
Assesment criterion
Points
achieved
PR
Optimise the design of the waste rooms and/or areas design by over-sizing and/or improving the
ergonomics of the area.
In case of recurring construction sites on the project, justified and satisfactory architectural
measures are taken to facilitate the shared sorting of operational waste and waste from recurring
construction
sites
on
the
project.
AND
Ensure that this shared sorting does not disrupt operational waste flows.
PR
* If the future users are not known, justify the estimate and the assumptions made.
60 /139
7. MAINTENANCE AND
DURABILITY OF
ENVIRONMENTAL
PERFORMANCES
STRUCTURE OF TARGET 7
7.1. OPTIMISING THE DESIGN OF THE BUILDING FOR THE SIMPLIFIED MAINTENANCE AND SERVICING OF THE
CONSTRUCTION FRAME AND SYSTEMS
7.2. DESIGNING THE BUILDING FOR THE MONITORING AND CONTROL OF ENERGY CONSUMPTION
7.3. DESIGNING THE BUILDING FOR THE MONITORING AND CONTROL OF SYSTEM PERFORMANCE AND COMFORT
CONDITIONS
61 /139
ASSESSMENT OF TARGET 7
TARGET 7
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Number of points to
obtain (if all points
are applicable) to
achieve level :
Spaces / Sub-targets
7.1
7.2
7.3
Totals
HP
NON-RESIDENTIAL
BUILDINGS
21
18
16
45
14
27
62 /139
Points
achieved
PR
Terminals
Access to all technical systems is possible and the means of access is adequately sized for all
equipment terminals in rooms of extended occupancy
PR
Ductwork
HVAC ductwork is sector-based and designed according to the technical structure of the building.
AND
Technical and architectural measures are taken to allow access to the distribution boxes.
63 /139
Assesment criterion
Points
achieved
7.1.3. Ensure easy access for maintenance and servicing of the building frame
Provide an accessibility study of the different components of the following categories:
Internal finishes (floor, walls and ceiling) and acoustic elements,
Internal partitions,
Windows, joinery and glazing,
Building faades,
Solar shading devices,
Rooftops.
AND
Proof that the architectural aspect chosen takes into account:
7.1.4. Guarantee the buildings performance levels and the user comfort conditions
Setting up a commissioning process for the programme, design and construction stage, relating to the
theme below:
Energy consumption
64 /139
7.2.
Design of the building for the monitoring and control of
energy consumption
Assesment criterion
Points
achieved
Metering devices are available for the equipment or systems that go beyond the five categories cited
in the PR above for fixed building services, and at least for the following services, where applicable:
Electromechanical equipment,
Cold production (process),
Parking lot lighting,
Outdoor lighting.
Metering devices are available for the equipment or systems that go beyond the five categories cited
in the PR above for fixed AND non-fixed building services and at least for the following categories,
where applicable:
Office equipment,
Swimming pool/spa,
Kitchen equipment and catering,
Laundry,
Lighting to emphasize objects and goods
Other energy equipment not dedicated to the comfort of occupants.
65 /139
Assesment criterion
Points
achieved
PR
Using the metering tree structure required above, for uses that lend themselves to sub-metering,
implementation of a sub-metering tree structure enabling the specific monitoring of water consumption
by area and/or water management system and/or water type via:
An initial sub-metering level,
If non-drinking water is being used, implementation of metering devices enabling the consumption of
the following water types to be monitored:
Rainwater,
AND/OR ground water,
AND/OR grey water.
66 /139
7.3.
Designing the building for the monitoring and control of
system performance and comfort conditions
Assesment criterion
Points
achieved
Room by room.
Installation of centralized means of inspection and management of artificial lighting area by area based
on natural lighting.
7.3.2. Make means available to optimise systems operation and fault detection
There are inspection means enabling:
Fault detection and alert generation (operating errors, deviations in consumption) for:
67 /139
8. HYGROTHERMAL
COMFORT
8
STRUCTURE OF TARGET 8
8.1.
8.2.
8.3.
CREATING HYGROTHERMAL COMFORT CONDITIONS IN ROOMS WHICH DO NOT HAVE ACCESS TO A COOLING
SYSTEM
8.4.
68 /139
ASSESSMENT OF TARGET 8
TARGET 8
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Spaces / Sub-targets
8.1
8.2
8.3
8.4
HP
NON-RESIDENTIAL
BUILDINGS OTHER THAN
REFRIGERATED
WAREHOUSES
10
10
10
10
20
REFRIGERATED
WAREHOUSES
10
10
10
10
19
69 /139
Points
achieved
PR
5
Justified, satisfactory measures are taken to control the effects of stratification and/or cold walls for
spaces where this is necessary. Justified, satisfactory measures
(1)
These measures are taken to address heating, cooling and/or hygrometry issues of throughout the
year.
(2)
This concern applies to periods where, in the same day, the building must address both heating and
cooling issues.
70 /139
8.2.
Assesment criterion
PR
1
8.2.3. Ensure air velocity that does not adversely affect comfort
Maximum air velocity within zones of occupation for spaces with extended occupancy:
Office spaces,
Teaching spaces,
Spaces devoted to sales,
Spaces associated with
retail buildings,
Shared spaces in hotel
buildings (excluding
bathing areas)
0.20m/s
0.15m/s
0.40m/s
0.15m/s
0.10m/s
0.30m/s
71 /139
Points
achieved
Assesment criterion
Functional devices are made available enabling users to change the heating level in these spaces,
within a given temperature range (to avoid deviations from the set point).
PR
Other spaces
Definition/achievement of a humidity ratio
AND
Measures are taken to provide humidity control.
appropriate
to
the
occupancy
conditions.
2
72 /139
8.3.
Creating hygrothermal comfort conditions in rooms which
do not have access to a cooling system (1)
REMINDER: IF THERE ARE ONLY COOLED SPACES THAT ENSURE A TEMPERATURE
SETPOINT, THIS SUB-TARGET DOES NOTAPPLY.
Assesment criterion
Points
achieved
Level B
Level A
8.3.2. Ensure sufficient ventilation and control the air flow if hygrothermal comfort is
achieved by opening windows or doors
Identification of the extended occupancy spaces where hygrothermal comfort is achieved by opening
windows
AND
justified window opening ratio for these spaces enabling natural ventilation to be provided
Justification that the equipment planned/installed makes it possible to keep the windows open in a
given position via a control, in order to naturally ventilate these spaces and modulate the incoming
airflow.
(1)
The purpose of this sub-target is to limit hygrothermal discomfort related to any overheating that
may occur in rooms without a cooling system.
(2)
According to the comfort ranges of the psychrometric diagram given in the practical guide.
73 /139
8.4.
Assesment criterion
PR
8.4.2. Ensure air speed that does not adversely affect comfort
Maximum air velocity in the zone of occupation of extended occupancy spaces , when the cooling
system is on, for a set point close to 26C(1):
Private guest
spaces in hotel
buildings
Common spaces
devoted to the
movement of
customers in retail
buildings
Spaces devoted to
sales in retail
buildings
V 0.25m/s
V 0.2m/s
V 0.8m/s
V 0.5m/s
V 0.22m/s
V 0.15m/s
V 0.5m/s
V 0.4m/s
8.4.3. Control solar gains and in particular localized discomfort due to heat radiation
Identification of the different types of spaces affected by localized discomfort due to solar gains (mainly
near
glass
walls
and
in
upper
parts)
AND
Technical and architectural measures are taken to limit localized solar discomfort
(1)
74 /139
Assesment criterion
Points
achieved
75 /139
9. ACOUSTIC COMFORT
9
STRUCTURE OF TARGET 9
9.1 CREATING AN ACOUSTIC ENVIRONMENT QUALITY APPROPRIATE FOR THE VARIOUS ROOMS
76 /139
ASSESSMENT OF TARGET 9
TARGET 9
ASSESSMENT
Compliance with PREREQUISITES
PR
PREREQUISITES
PERFORMING
HIGH
PERFORMING
AND
50% of the APPLICABLES points per space category
PREREQUISITES
AND
75% of the APPLICABLES points per space category
Number of points
available
Spaces
9.1
Totals
HP
0*
* Exception: Table does not apply if the target is assessed at PERFORMING level
77 /139
Assesment criterion
PR
PR
Standardized sound level difference between spaces and outdoor noise: D2m, nT, w 30 dB
Weighted standardized
LnT, w 60 dB
impact
sound
pressure
level
78 /139
LnT,
transmitted
into
spaces:
Assesment criterion
Points
achieved
Equivalent absorption area (EAA) of coverings (with proof of uniformity in each area):
EAAtotal 0.6 S(floor surface) in individual and shared offices
EAAfloor+ceiling 0.6 S(floor surface) for open office spaces,
OR
Reverberation time 0.6 < Tr < 0.8 s for a volume < 250m
Reverberation time Tr 1 s for a volume > 250m
Weighted standardized sound level difference DnT, w between office spaces (receiving) and any type
of "office" activity space (emitting):
DnT,w 38 dB between individual offices (receiving) and any type of "office" activity space
(emitting)
DnT,w 35 dB between shared offices (receiving) and other shared offices and open spaces
(emitting)
DnT,w 32 dB between open spaces (receiving) and other open spaces and shared offices
(emitting)
Same as level above
AND
Performing an acoustic study on office space with fixed partitioning, under the 6 acoustic environment
criteria below:
Weighted standardized acoustic insulation from outdoor space
Equipment noise level
Impact noise level
Indoor acoustics (based on specific indoor acoustic indicators)
Airborne noise insulation (receiving) from adjacent spaces
Walking noise
AND implementation of solutions identified as the most suitable by this study *
* If the study concludes that one or more 2-point level thresholds above have no usefulness in the
project background, and recommends a lower threshold or thresholds, the 4 points are achieved if the
study recommendations are adhered to.
79 /139
Assesment criterion
PR
PR
difference
Weighted standardized
LnT, w 60 dB
Standardised
Lra 43 dB (A)
sound
impact
between
sound
pressure
pressure
level
spaces
level
and
LnT,
Lra
2
outdoor
transmitted
caused
by
noise:
into
spaces:
equipment:
Equivalent absorption area (EAA) of coverings (with proof of uniformity in each area):
EAAfloor+ceiling 0.6 S(floor surface) for open office spaces,
OR
Reverberation time Tr 0.9 s for a volume < 250m3
Reverberation time Tr 1 s for a volume > 250m3
Weighted standardized sound level difference DnT, w between modular office spaces achievable once
the platforms are partitioned** (between technical floors and extended ceilings): DnT, w 32 dB
80 /139
Assesment criterion
Points
achieved
81 /139
Points
achieved
PR
PR
82 /139
Assesment criterion
Same
as
level
above
AND
Performing an acoustic study on training and practical workrooms, under the 6 acoustic environment
criteria below:
Weighted standardized acoustic insulation from outdoor space
Equipment noise level
Impact noise level
Indoor acoustics (based on specific indoor acoustic indicators)
Airborne noise insulation (receiving) from adjacent spaces
Walking noise
AND implementation of solutions identified as the most suitable by this study*.
* If the study concludes that one or more 2-point level thresholds above have no usefulness in the
project background, and recommends a lower threshold or thresholds, the 4 points are achieved if the
study recommendations are adhered to.
83 /139
Points
achieved
PR
PR
84 /139
Assesment criterion
Points
achieved
AND realization of an acoustic study on common spaces devoted to the movement of customers
* If the study concludes that one or more 2-point level thresholds above have no usefulness in the
project background, and recommends a lower threshold or thresholds, the 4 points are achieved if the
study recommendations are adhered to.
85 /139
3
4
Assesment criterion
PR
PR
sound
pressure
level
Lra
caused
by
equipment:
Weighted standardized sound level difference DnT, w between the common spaces (receiving) and a
delivery
space
or
waste
area
(emitting):
DnT, w 45 dB or lower value set by a special acoustic study.
86 /139
Internal acoustics (based on specific internal acoustic indicators that guarantee that messages
broadcast by a public address system are intelligible)
Assessment criterion
Points
achieved
Insulation from airborne noise (receiving) from spaces other than delivery spaces and waste
areas
AND implementation of the solutions identified by this study* as the most suitable:
For three criteria (at least).
For all five criteria.
* If the study concludes that one or more 2-point level thresholds above have no usefulness in the
project background, and recommends a lower threshold or thresholds, the 4 points are achieved if the
study recommendations are adhered to.
87 /139
3
4
Assesment criterion
PR
PR
Sound level difference of private spaces from outdoor noise: D2m, nT, w 30 dB
Weighted standardized impact sound pressure level transmitted into rooms devoted to sleeping: LnT,
w 60 dB
Standardised sound pressure level Lra caused by equipment in rooms devoted to sleeping:
Lra 35 dB(A) when the equipment is located in the room
Lra 30 dB(A) otherwise
Equivalent absorption area (EAA) of coverings in corridors leading to the rooms in buildings or parts
of buildings used as hotels: EAAtotal 0.25 S (floor surface)
Weighted
standardized
sound
level
Lra compliant with the table in the practical guide
difference
88 /139
Lra
of
private
spaces:
Assesment criterion
Points
achieved
89 /139
Points
achieved
PR
Standardised sound pressure level LnAT caused by equipment in spaces in the "warehouse" area: Lra
62 dB (A)
Operations office
Particular care taken with the acoustics of the operations office located near the warehouse. The indoor
airborne sound insulation between the operations office and the warehouse must be DnT, w> 35 dB
Warehouse Spaces
Realization of a special acoustic study and compliance with the study's requirements with respect to
insulating against airborne noise from adjacent spaces.
* Exception: Table does not apply if the target is assessed at PERFORMING level
90 /139
Points
achieved
91 /139
Points
achieved
PR
Compliance with the defined PERFORMING level for all six criteria.
3
4
92 /139
10.
VISUAL COMFORT
10
STRUCTURE OF TARGET 10
10.1 OPTIMISING NATURAL LIGHTING
10.2 COMFORTABLE ARTIFICIAL LIGHTING
93 /139
ASSESSMENT OF TARGET 10
ASSESSMENT
TARGET 10
PR
PERFORMING
HIGH
PERFORMING
94 /139
Number of points
to obtain (if all
points are
applicable) to
achieve the
Performing level:
Number of points
to obtain (if all
points are
applicable) to
achieve the High
Performing level:
10.1
10.2
Totals
10.1
10.2
10.1
10.2
OFFICE SPACES
10
13
23
10
10
13
23
10
10
13
23
10
13
20
10
EXHIBITION HALL
10
13
23
10
20
13
33
10
15
10
10
13
23
10
"CONTROLLED-TEMPERATURE
WAREHOUSE" (REFRIGERATED
WAREHOUSE) SPACE
13
18
10
11
13
24
10
OTHER CHARACTERISTIC
SPACES OF ACTIVITY
(Relating to an activity not
covered by a previous table)
13
18
10
95 /139
OFFICE SPACES
Assesment criterion
Points
achieved
PR
96 /139
PR
Assesment criterion
Points
achieved
DF 2% for 80% of the first-level area's surface, in 80% of the rooms in question (by surface
area)
DF 1.5% for 80% of the first-level area's surface, in 20% of the remaining rooms in question
(by surface area)
DF 2.5% for 80% of the first-level area's surface, in 80% of the rooms in question (by surface
area)
DF 1.5% for 80% of the first-level area's surface, in 20% of the remaining rooms in question
(by surface area)
AND
DF 0.7% for 90% of the second-level area's surface in all rooms in question
Second day lighted rooms (rooms above that are not directly exposed to faades looking
outdoors)
DF 0.7% over 70% of the surface area of 70% of second-day lighted rooms (by surface area)
The thresholds may be decreased by 0.5% under certain special conditions (see practical
guide) (except for levels at 0.7%)
The percentages apply to the surface areas on a weighted basis (see calculation method in the
practical guide)
The sensitive spaces in question are mentioned in the practical guide
Identify glare-sensitive spaces requiring the incoming natural light to be controlled and study the glare
and
control
conditions
of
natural
light
in
these
spaces.
AND
Proven and satisfactory measures to guide, filter and/or diffuse daylight in these spaces in order to
control the incoming natural light and limit direct or indirect glare in these spaces.
97 /139
Points
achieved
PR
PR
DF 2% for 80% of the first-level area's surface, in 80% of the rooms in question (by surface
area)
DF 1.5% for 80% of the first-level area's surface, in 20% of the remaining rooms in question
(by surface area)
DF 2.5% for 80% of the first-level area's surface, in 80% of the rooms in question (by surface
area)
DF 1.5% for 80% of the first-level area's surface, in 20% of the remaining rooms in question
(by surface area)
AND
DF 0.7% for 90% of the second-level area's surface in all rooms in question
Second day lighted rooms (rooms above that are not directly exposed to faades looking
outdoors)
DF 0.7% over 70% of the surface area of 70% of second-level rooms (by surface area)
The thresholds may be decreased by 0.5% under certain special conditions (see practical
guide) (except for levels at 0.7%)
The percentages apply to the surface areas on a weighted basis (see calculation method in the
practical guide)
The sensitive spaces in question are mentioned in the practical guide
98 /139
Assesment criterion
Points
achieved
Identify glare-sensitive spaces requiring the incoming natural light to be controlled and study the glare
and
control
conditions
of
natural
light
in
these
spaces.
AND
Proven and satisfactory measures to guide, filter and/or diffuse daylight in these spaces in order to
control the incoming natural light and limit direct or indirect glare in these spaces.
99 /139
Points
achieved
PR
PR
Identify glare-sensitive areas in large common spaces requiring the incoming natural light to be
controlled and study the glare and natural lighting control conditions in these areas.
AND
Proven and satisfactory measures to guide, filter and/or diffuse daylight in these areas in order to
control the incoming natural light and limit direct or indirect glare in these areas.
100 /139
Points
achieved
PR
101 /139
Assesment criterion
Points
achieved
102 /139
EXHIBITION HALL
Points
achieved
Assesment criterion
definition)
PR
PR
Provide natural lighting in the hall by integrating openings into the building faades (the ratio of
translucent area to total building faade area must be greater than or equal to 30% with minimum light
transmission of 50%)
103 /139
Points
achieved
PR
PR
Lounge areas
Access to daylight in:
60% of lounge areas
Walkways are those frequented by guests and are not covered by the 'large common spaces devoted
to movement' table
104 /139
Assesment criterion
Points
achieved
PR
PR
Lounge areas
Access to views in:
60% of lounge areas
Walkways are those frequented by guests and are not covered by the 'large common spaces devoted
to movement' table
105 /139
Points
achieved
1
2
1
2
106 /139
Points
achieved
Access to outside views from the dock area for 15% of the dock's length.
107 /139
Points
achieved
PR
Walkways
Have daylight visible in:
30% of the surface area of walkways
Other spaces sensitive to natural lighting (food-service areas, meeting rooms, infirmaries,
open rest areas, auditoriums, training rooms, documentation centers, reading rooms, childcare
centers)
Access to daylight, but no surface area percentage requirements
Access to daylight in:
40% of the surface area of sensitive spaces
60% of the surface area of sensitive spaces
PR
1
2
PR
Walkways:
Access to views (horizontal to line of sight) in at least 50% of the surface areas of walkways.
Other spaces sensitive to natural lighting (food-service areas, meeting rooms, infirmaries,
open rest areas, auditoriums, training rooms, documentation centers, reading rooms, childcare
centers)
Access to views, but no surface area percentage requirements
Access to views in:
40% of the surface area of sensitive spaces
60% of the surface area of sensitive spaces
108 /139
PR
1
2
Assesment criterion
Points
achieved
The thresholds may be decreased by 0.5% under certain special conditions (see practical
guide) (except for levels at 0.7%)
The percentages apply to the surface areas on a weighted basis (see calculation method in the
practical guide)
The sensitive spaces in question are mentioned in the practical guide
Identify glare-sensitive spaces requiring the incoming natural light to be controlled and study the glare
and
control
conditions
of
natural
light
in
these
spaces.
AND
Proven and satisfactory measures to guide, filter and/or diffuse daylight in these spaces in order to
control the incoming natural light and limit direct or indirect glare in these spaces.
109 /139
Points
achieved
PR
PR
10.1.3. Creation of spaces with a minimum level of natural lighting and optimum
treatment of the quality of natural light
Natural light visual comfort indicators:
Lighting level
Quality of light treatment
Two solutions can be used to prove the achievement of the prerequisite:
1- Complying with the programme's target figures or the applicants contractual requirements for
each indicator above
2- Defining three performance levels for each indicator:
CURRENT LOCAL STANDARD PRACTICE level;
PERFORMING level;
HIGH-PERFORMING level;
and complying with the CURRENT LOCAL STANDARD PRACTICE level, proven by a natural lighting
study performed on the spaces characteristic of the activity with respect to the two visual comfort
indicators above visual environment criteria above
PR
110 /139
10.2.
Points
achieved
PR
At least 0.1 greater than the uniformity factors of the previous level over the total surface area
of the room, less a maximum strip of 0.5 around the perimeter.
10.2.3. Avoid glare due to artificial lighting and seek a balance between light sources
from the surrounding light environment
Identify the risks of artificial lighting glare and measures taken to install light fixtures according to the
furnishing layout so as to avoid artificial lighting glare. Comply with the recommendations of standard
NBR ISO/CIE 8995-1
PR
Comply with the Unified Glare Rate (UGR) stipulated by standard NBR ISO/CIE 8995-1
OR
Study the conditions for balancing light sources in the indoor environment. Proven, satisfactory
measures.
Carry out a study on the conditions for balancing light sources in the indoor environment with respect
to the combined artificial AND natural lighting. Proven, satisfactory measures.
111 /139
Assesment criterion
Points
achieved
For each type of sensitive space, carry out a lighting study taking into account at least three of the
criteria below:
112 /139
11. OLFACTORY
COMFORT
11
STRUCTURE OF TARGET 11
11.1 CONTROLLING THE SOURCES OF UNPLEASANT ODOURS
ASSESSMENT OF TARGET 11
TARGET 11
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
113 /139
Spaces / Sub-targets
NON-RESIDENTIAL
BUILDINGS
Number of points to
obtain (if all points are
applicable) to achieve
level :
11.1
HP
Spaces / Sub-targets
NON-RESIDENTIAL
BUILDINGS
Number of points to
obtain (if all points are
applicable) to achieve
level :
13.1
HP
13
114 /139
Points
achieved
PR
2
11.1.2. Treat foul-smelling waste emissions in order to prevent odours from spreading
Identify waste emissions, which are a source of unpleasant odours and take measures to treat these
odours in order to prevent them from being spread.
115 /139
STRUCTURE OF TARGET 12
12.1 LIMITING ELECTROMAGNETIC EXPOSURE
12.2 CREATING SPECIAL HEALTH CONDITIONS
116 /139
12
ASSESSMENT OF TARGET 12
TARGET 12
ASSESSMENT
PR
PERFORMING
HIGH
PERFORMING
Sub-targets
NON-RESIDENTIAL
BUILDINGS
Number of points to
obtain (if all points
are applicable) to
achieve level :
12.1
12.2
Totals
HP
13
20
10
15
117 /139
Points
achieved
PR
"Telecom" sources
Identify sources of radio waves from the immediate environment.
Identify sources of radio waves from the immediate environment
AND estimate the surrounding electromagnetic field and that of the project
AND express the project's contribution to overall exposure
PR
"Telecom" sources
Take proven and satisfactory measures to optimise the electromagnetic field of the project.
118 /139
12.2.
Points
achieved
PR
Identify
areas
and
rooms,
which
are
sensitive
to
special
health
conditions
AND
Measures taken to create optimal health conditions in areas and rooms that are sensitive to special
health conditions with respect to particular activities.
PR
2
12.2.3. Choose materials that limit the growth of fungi and bacteria (*)
For rooms that are sensitive to special health conditions
For these rooms, whose surfaces are regularly wet down and cleaned, known health characteristics
for all members of the internal coverings category (floors, walls, ceilings), including finishing products.
AND take into account the health criteria when choosing a product, at least for the member of that
category with the greatest impact.
2
4
AND take into account the health criteria when choosing a product, at least for the member of that
category with the greatest impact.
All paints and varnishes are treated with fungicides and bactericides.
(*) Does not apply to warehouses of logistics platforms and shipping docks or exhibition halls.
119 /139
13
STRUCTURE OF TARGET 13
13.1. GUARANTEEING EFFECTIVE VENTILATION
13.2 CONTROLLING SOURCES OF INDOOR AIR POLLUTION
120 /139
ASSESSMENT OF TARGET 13
ASSESSMENT
TARGET 13
PR
PERFORMING
HIGH
PERFORMING
Spaces / Sub-targets
NON-RESIDENTIAL
BUILDINGS
Number of points to
obtain (if all points
are applicable) to
achieve level :
13.1
13.2
Totals
HP
13
10
23
14
Number of points to
obtain (if all points
are applicable) to
achieve level :
Spaces / Sub-targets
2.4
Totals
HP
NON-RESIDENTIAL
BUILDINGS
14
14
121 /139
Assesment criterion
13.1.1. Provide air flows suitable for the activity of the rooms
Implement one or more special ventilation system(s) (mechanical or natural). Simply manually
opening
the
windows
is
not
sufficient.
AND
If natural ventilation is planned in some spaces and it is not controlled, additional mechanical ventilation
must
be
provided.
AND
With mechanical ventilation present:
PR
Evidence of attainment of fresh air flows at least compliant with level 1 of outdoor air in
accordance with NBR 16401-3.
Balancing of main ventilation branches
Adherence to design recommendations da NBR 16401-3
Study and measures taken to ensure that the airflows supplied and the indoor air quality conditions
are:
At least compliant with level 2 of outdoor air in accordance with NBR 16401-3
AND
compliant with appendix B4 of standard EN 15251:2007 for unoccupied premises,
for
all
spaces
(method
defined
AND
Evidence of fresh airflows by means of measurement.
122 /139
in
the
practical
3
guide).
Points
achieved
Assesment criterion
Study and measures taken to ensure that the airflows supplied and the indoor air quality conditions
are:
At least compliant with level 3 of outdoor air in accordance with NBR 16401-3,
AND
compliant with appendix B4 of standard EN 15251:2007 for unoccupied premises,
for
all
spaces
(method
defined
AND
Evidence of fresh airflows by means of measurement.
in
the
practical
4
guide).
Modulate the flows according to the CO2 level at least in spaces occupied intermittently.
123 /139
PR
Assesment criterion
Points
achieved
124 /139
13.2.
Points
achieved
13.2.1. Identify and reduce the effects of internal and external sources of pollution
Drawing up a descriptive booklet identifying the internal non-building pollution sources and external
sources
AND
Justified and satisfactory measures taken with respect to the project to reduce their effects.
125 /139
PR
Assesment criterion
Points
achieved
1
2
3
4
As above AND: Comply with the following health reference values for the following pollutants:
Nitrogen dioxide (NO2):40 g.m-3
Carbon monoxide (CO) (if source):
10 g.m-3 for an exposure of 8 hours
30 g.m-3 for an exposure of one hour
Benzene:< 5 g.m-3
Formaldehyde:< 30 g.m-3
TVOC:level 1: < 300 g.m-3
Particles (PM2.5 and PM10):long term: PM 10: < 20 g.m-3 and PM 2.5: < 10 g.m-3
As above AND:
Benzene:< 2 g.m-3
Formaldehyde:< 10 g.m-3
126 /139
14
STRUCTURE OF TARGET 14
14.1. DESIGN QUALITY OF THE BUILDINGS INTERNAL WATER NETWORK
14.2. CONTROLLING THE TEMPERATURE INSIDE THE BUILDINGS INTERNAL WATER NETWORK
14.3. CONTROLLING WATER TREATMENTS
14.4. WATER QUALITY IN BATHING AREAS
127 /139
ASSESSMENT OF TARGET 14
TARGET 14
ASSESSMENT
PR
PERFORMING
HIGH
AND
75% of the APPLICABLES points
PERFORMING
Number of points to
obtain (if all points
are applicable) to
achieve level :
Sub-targets
NON-RESIDENTIAL
BUILDINGS
14.1
14.2
14.3
BATHING AREAS
14.4
128 /139
Totals
HP
17
13
23
12
17
Points
achieved
14.1.1. Choose materials compatible with the nature of the water being distributed
Specification of materials in contact with water intended for human consumption in accordance with
regulations, and supplier compliant with correspondent PSQ or SINAT of PBQP-H
For all the chosen materials, respect to the compositions and impurity content defined by regulation.
For any contact with water intended for human consumption, choose materials that allow the curative
thermal or chemical treatment of the cold water network in the event of contamination
PR
14.1.3. Provide structure and signs to the indoor network based on water usage
If reclaimed water is used
PR
Identify the water usages in the project and the locations of consumption points and arrange the
internal water network into standard networks, in accordance with the practical guide.
129 /139
Assesment criterion
Points
achieved
130 /139
Points
achieved
PR
14.2.2. Optimise the design the DHW network(s) so as to limit the risk of legionellosis
Where a looped network(s) is/are present
Design of looped networks based on balance calculations and taking in account the
adjustability limits of the regulating devices.
A balanced system guaranteeing a speed greater than 0.20 m/s is implemented in all loop
returns
A temperature of 55C is guaranteed at all points of the DHW distribution systems (except for
antennas that serve high-risk consumption points whose volume is less than 3 liters).
131 /139
Points
achieved
Assesment criterion
14.2.3. Maintain and control the temperature of the DHW and DCW networks
Separately insulate the DHW and DCW networks AND measures taken to prevent the DCW pipelines
from heating
Where
a
looped
Measures taken on the DCW network to:
network(s)
is/are
present
control the temperature of each loop return and at the identified high-risk points;
automatically control (via an automatic monitoring and management system) the temperatures
of the looped network, controlling the temperatures at least on the start points and returns of
each main loop.
132 /139
14.3.
Points
achieved
14.3.2. Manage the health risk related to the recovery and reuse of non- water
recovered on-site (and treat reused water)
If non-drinking water is reused on-site for internal use(s)
Measures taken to guarantee the quality of non-drinking water at the usage points by means of an
appropriate additional treatment process (if required).
133 /139
14.4.
BATHING AREAS
Points
achieved
Assesment criterion
implemented
PR
0.1 mg/L
134 /139
Part II:
Terminology
135 /139
Activity
Building or part of a building comprising one dominant functionality, associated with a cluster of spaces
intended to be used for the activity in question, which may be carried out entirely independently of the
building's other activities where they exist.
Example:
Theatre activity: Spaces for performance halls, wings, dressing rooms, offices, meeting rooms, etc.
Secondary education activity: Spaces for classrooms and practical activities, administration and staff
rooms, etc.
Hotel activity: Private guests areas, lounge areas, receptions, etc.
Applicability
Occasionally, some requirements may prove not to apply; the reason should be obvious. Where this is not
the case, it must be justified by the specific characteristics of the project. In this case, the requirement is
ignored and the assessment carried out as if it did not exist. Please note that the prerequisites remain
applicable.
Management
Target 4: Energy management
Target 5: Water management
Target 6: Activity waste management
Target 7: Maintenance Sustainability of environmental performance
Comfort
Target 8: Hygrothermal comfort
Target 9: Acoustic comfort
Target 10: Visual comfort
Target 11: Olfactory comfort
Health
Target 12: Sanitary quality of spaces
Target 13: Sanitary quality of air
Target 14: Sanitary quality of water
136 /139
Requestor
Natural person or legal entity for whom the building is constructed and who asks for the structure to be
certified.
Programme entity
Brings all spaces relating to a single activity under the responsibility of a single requestor for a single building,
which may be assessed by one building environmental performance certification technical scheme.
An EPB assessment is associated with each programme entity
Environment
Surroundings in which an organization operates, including air, water, earth, natural resources, flora, fauna,
human beings and their interrelationships. [ISO 14001]
137 /139
Parties involved
Participants in the act of building, usually bound to the requestor under a contract.
For this certification, the parties involved are, for example, the assistant to the certification requestor, the
programme manager, the architect, the engineering and design departments, the technical inspection
department, the quantity surveyor, businesses, craftspeople, etc.
Project
Building, associated services and all processes leading to the completion of the building.
Stakeholder
Individual or group concerned with or affected by the environmental performance of an organization.[ISO
14001]
For this certification, the stakeholders are, for example, users of the building, elected officials, policy makers,
future users, future managers, local communities, residents, local associations concerned with the
environment, various organizations concerned by the project's environmental aspects, etc.
Environmental concern
Concrete, operational topic relating to the environmental and sanitary impacts of buildings for which means
of action may be implemented.
Programming
Phase during which the programme, a document for the attention of the architect for the architectural and
technical design of the building, is drawn up. For the needs of this certification, programming consists of
defining the expected or desired performance levels of the building.
Prerequisite
Minimum level a building must attain on a target in order to be HQE certified.
138 /139
Principle of equivalence
Given the variety of technical and architectural solutions that contribute to the EPB and that are not generally
possible to predict, and in order to encourage innovation, the project participants may apply a 'principle of
equivalence' for the Performing and High Performing levels.
This consists of proposing, with appropriate justification, an alternative assessment method based on
assessment criteria other than those in the Assessment Scheme for the Environmental Performance of
Buildings but addressing the same concern. This principle makes verifying the assessment more
complicated (where necessary calling in an expert to validate the approach), but gives some flexibility to the
scheme.
Sector
General term referring to a cluster of spaces covering similar activities.
For example, for the 'office' sector, the following activities may be cited: 'office building', 'police station', 'call
center', 'non-medical healthcare center', 'business center', etc. All of these activities share the 'office'
characteristic space, whether individual, collective or open-plan.