Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

EAOM - 36
Hz./
RPM

FAILED TO START

RPM

SPEED
FAILURE

Features
Designed For Generator, Pump & Fire Pump Applications
Remote start / stop capability with zero power consumption
Engine start and stop
Automatic shutdown on fault condition
Provides alarm and status information
Alarm and shutdown inputs
Provides charge alternator excitation current
Lamp test function

CHARGING FAIL

~
~
~
~~
~ HIGH TEMPERATURE

Fail Monitoring
LOW OIL PRESSURE

0
STOP

Oil pressure
Engine temperature
Over speed & Under speed (generator application)
Charging alternator
Conf. Input-1 & 2

I
START

Controls
Engine fuel or stop solenoid
Starter motor
Preheat, simulate fuel solenoid, external alarm
horn, alarm or load contactor out

EAOM-36 Manual Start Unit use microprocessor based technology to provide integrated manual start and
fault protection in a wide range of engine applications. The module is housed in 72x72 DIN size.The module is
used to start and stop the engine, indicating the operational status and fault conditions. Automatically shutting
down the engine and indicating the engine failure by a flashing LED. User can control the engine via a two position
key switch and pushbuttons mounted on the front panel or with remote input.
The module has three application feature; 'Generator', 'Pump' or 'Fire Pump'. (can be selected from
parameter P00).
The module can connect directly with engine, thanks to high current relay outputs.
The module has two feature for fuel. One of energize to run the other energize to stop. User can select the
feature from program parameters.
The module protect the engine against fault conditions. If a fault condition occurred, the module indicate the fault
condition and shut-down the engine.
If the key switch is OFF position the module has zero power consumption to save energy. The module energizes
when the key switch position is getting ON position. If Satart button is pressed, the Conf. Out relay output (if selected
preheat output) will activate until the preheat delay is expired.
Press Start button for starting the engine. When engine is running, module will stop the cranking.
Press Stop button for stoping the engine. After pressing the stop button, the engine will keep running until cooling
time(P21) is expired.
Also the module has remote start facility. Please select suitable type of remote start for your application from
program parameters. If remote start input is active the module will start the engine. If remote start is passive the unit will
stop the engine after cooling time is expired.
The module will check the alarms after safety on timer is expired.
Under one of this fault conditions the module will stop the engine;
- Over speed (generator application),
- Under speed(generator application),
- High Temperature,
- Low Oil Pressure,
- Shutdown (if one of conf. input selected shutdown and activated).
To reset the fault, turn the key switch to the OFF position for a few seconds.
The Charge Failure is a warning alarm so the engine continue to work under this failure condition. Also this input
supplying charge alternator excitation current.
Shutdown the engine;
If the engine fuel type is energize to stop, press Stop button until the engine comes to rest. After that select OFF
position of the key switch.
If the engine fuel type is energize to run, select OFF position of the key switch.
Important note: On the Fire Pump application; If a fault condition occurred, the module will not stop the engine.
The engine will be stopped only when the stop button was pressed or the remote stop signal was detected.

Introduction Brochure. ENG EAOM-36R 01 V05 07/13

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Program Parameters for Generator Application
Prog No
P 00
P 01
P 02
P 03
P 04
P 05
P 06
P 07
P 08
P 09
P 10
P 11
P 12
P 13
P 14
P 15
P 16

P 17

P 18

P 19

P 20
P 21
P 22

Parameter Name
Application Selection (Generator, Pump, Fire Pump)
Frequency Lower Limit
Frequency Upper Limit
Nominal Alternator Frequency
Nominal Speed
Stop/Fuel Solenoid Selection
Stop Solenoid Energising Time
Crank Disconnect on Gen. Frequency
Crank Disconnect on Charge Alternator Voltage
Crank Disconnect on Oil Pressure
Number of Starting Attempts
Starting Attempt Duration
Oil Pressure Bypass Time
Safety On Delay
Frequency Fault Control Delay
Engine Running Time Value & New Engine Running Time
Remote Start Selection:
0 - Disable. The start / stop buton is used. (leave key switch 1 position)
1 - When the -BATTERY applied to Rem. start input (terminal-11),
the engine start cranking. (leave key switch 1 position)
2 - When the +BATTERY applied to +BAT input (terminal-3),
the engine start cranking. (leave key switch 1 position)
Conf. Out Type: 0- Alarm Out, 1- Horn Out,
2- Preheat Out, 3- Simulate Fuel Solenoid Out,
4- Load Contactor Out
Conf. Input 1
0 - Only horn temporary, observation continuously
1 - Only horn permanent, observation continuously
2 - Engine stop, observation continuously
3 - Only horn temporary, observation while engine running
4 - Only horn permanent, observation while engine running
5 - Engine stop, observation while engine running
Conf. Input 2
0 - Only horn temporary, observation continuously
1 - Only horn permanent, observation continuously
2 - Engine stop, observation continuously
3 - Only horn temporary, observation while engine running
4 - Only horn permanent, observation while engine running
5 - Engine stop, observation while engine running
Horn Duration
Cooling Time
Password

Unit
Hz.
Hz.
Hz.
Rpm
Sec.
Hz.
Number
Sec.
Sec.
Sec.
Sec.
Hour
-

Limits
GEn, PUP, FPU
30.0 - 75.0
30.0 - 75.0
30.0 - 75.0
500 - 5000
StoP - FUEL
1 - 99
25.0 - 75.0
diS - EnAb
diS - EnAb
1 - 10
5 - 99
0 - 99
0 - 99
0.0 - 10.0
0 - 9999
0= diS 1 - 2

Default
GEn
47.0
53.0
50.0
1500
FUEL
20
30.0
diS
EnAb
3
5
30
10
3.0
0
diS

0-4

0-5

0-5

Sec.
Sec.
-

0= Cont. 1 - 999
0(dis) - 3600
0 - 9999

30
0
0

Warning: P16 Remote Start Selection parameter option 2 can not be used with stop solenoid type generators.

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Program Parameters for Pump (Fire Pump) Applications
Prog No
P 00
P 05
P 06
P 08
P 09
P 10
P 11
P 12
P 13
P 15
P 16

P 17

P 18

P 19

P 20
P 21
P 22

Parameter Name
Application Selection (Generator, Pump, Fire Pump)
Stop/Fuel Solenoid Selection
Stop Solenoid Energising Time
Crank Disconnect on Charge Alternator Voltage
Crank Disconnect on Oil Pressure
Number of Starting Attempts
Starting Attempt Duration
Oil Pressure Bypass Time
Safety On Delay
Engine Running Time Value & New Engine Running Time
Remote Start Selection:
0 - Disable. The start / stop buton is used. (leave key switch 1 position)
1 - When the -BATTERY applied to Rem. start input (terminal-11),
the engine start cranking. (leave key switch 1 position)
2 - When the +BATTERY applied to +BAT input (terminal-3),
the engine start cranking. (leave key switch 1 position)
Conf. Out Type 0- Alarm Out, 1- Horn Out,
2- Preheat Out, 3- Simulate Fuel Solenoid Out,
4- Load Contactor Out
Conf. Input 1
0 - Only horn temporary, observation continuously
1 - Only horn permanent, observation continuously
2 - Engine stop, observation continuously
3 - Only horn temporary, observation while engine running
4 - Only horn permanent, observation while engine running
5 - Engine stop, observation while engine running
Conf. Input 2
0 - Only horn temporary, observation continuously
1 - Only horn permanent, observation continuously
2 - Engine stop, observation continuously
3 - Only horn temporary, observation while engine running
4 - Only horn permanent, observation while engine running
5 - Engine stop, observation while engine running
Horn Duration
Cooling Time
Password

Unit
Sec.
Number
Sec.
Sec.
Sec.
Hour
-

Limits
GEn, PUP, FPU
StoP - FUEL
1 - 99
diS - EnAb
diS - EnAb
1 - 10
5 - 99
0 - 99
0 - 99
0 - 9999
0= diS 1 - 2

Default
PUP
FUEL
20
diS
EnAb
3
5
30
10
0
diS

0-4

0-5

0-5

Sec.
Sec.
-

0= Cont. 1 - 999
0(dis) - 3600
0 - 9999

30
0
0

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Specifications
Equipment Use
Housing & Mounting
Panel Cut-out
Protection
Weight
Environmental Rating
Operating / Storage Temperature
Operating / Storage Humidity
Installation Over Voltage Cat.
Pollution Degree
Mode of Operation
EMC
Electrical Safety
Supply Voltage(Z)
Generator Speed Measurement
Alternator Frequency Range
Frequency Meas. Accuracy
Cranking Dropouts

Electrical control equipment for generating sets


72 mm x 72 mm x 52 mm
68 mm x 68 mm
NEMA4X (IP30 at front panel, IP20 at rear side)
Approximately 190 gr
Standard, indoor at an altitude of less then 2000 meters with non-condensing humidity
-25C to +70C / -40C to +85C
90% max. (Non-condensing)
II appliances, portable equipment
II, Normal office or workplace, non-conductive pollution
Continuous
EN-61000-6-4, EMC generic emission standard for industrial equipment
EN-61000-6-2, EMC generic immunity standard for industrial equipment
EN-61010-1, safety requirements for electrical equipment for measurement, control and
laboratory use
8 - 32 VZ
From generator voltage
15,6 to 99,9 Hz (15 to 300 VL-NV RMS)
0.5%
Battery voltage can be 0VZ for max. 100msn during cranking (battery voltage should be
at least nominal voltage before cranking)

Relay Outputs

Start relay (10A@28VZ)


Fuel relay (10A@28VZ)
Conf. Out relay (10A@28VZ)

Failure Indicators

Failed to engine start


High engine temperature
Low oil pressure
Speed failure
Battery charge failure
General failure

Status Indicators

Hz./RPM
Engine running time
Engine start
Engine stop

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Dimensions & Front View
EAOM - 36
Hz./
RPM

RPM

SPEED
FAILURE

72 mm

FAILED TO START

CHARGING FAIL

~
~
~
~~
~ HIGH TEMPERATURE

LOW OIL PRESSURE

0
STOP

START

72 mm

5 mm

47 mm

68 mm

Panel Cut-Out

TEN A

68 mm

EAOM-36.RF Terminal Connections (Fail Safe)

+BAT

FUEL
CONF.O

5
6
7

HIGH TEMP.

CONF. INPUT-2
OR REMOTE START
(P16=1 => REM. INPUT)

LOW OIL PRES.

+BAT

START

10A@28VDC

FUEL
10A@28VDC

CONF.O
10A@28VDC

+BAT

12

-BAT

13

L1
N

10

11

(+)CHARGE GEN.
D+(W.L.)

GND
TX
RX

CONF. INPUT-2
OR REMOTE START
(P16=1 => REM. INPUT)

10A@28VDC

10A@28VDC

10A@28VDC

CONF. INPUT-1
-BAT

11

CONF. INPUT-1
-BAT

2
3

(+)CHARGE GEN.
D+(W.L.)

START

10

-BAT

LOW OIL PRES.

RS 232

-BAT

HIGH TEMP.

RS 232

EAOM-36.R Terminal Connections

+BAT

12

-BAT

13

GND
TX
RX

L1
N

GENERATOR
VOLTAGE
300VAC (Ph-N) Max.

GENERATOR
VOLTAGE
300VAC (Ph-N) Max.

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Connection Schematic (Without Remote Start P16 = 0 (dis))

c2

12

10

11

CONF.OUT

STARTER

HORN

CONF. INPUT-2

CHARGE
GEN. D+(W.L.)

CONF. INPUT-1

HIGH TEMPERATURE

BATTERY

LOW OIL PRESSURE

CHARGE
GENERATOR

40 A

START
RELAY

40 A

SOLENOID
RELAY
B+

OR LOAD CONTACTOR

+BAT

FUSE-1

-BAT

+BAT

PREHEAT, ALARM

10A@28VDC

10A@28VDC

13

10A@28VDC

N
L1

FUSE-2

ALTERNATOR

BATTERY NEGATIVE MUST BE GROUNDED

The fuses should be as follows:


FUSE-1
According to current required by solenoids (Max. 16A. T)
FUSE-2
Max. 1A. T

1- Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and
battery negative should be grounded.
2- Use Alternator connection only generator application (P00 = Gen)

Connection Schematic (With Remote Signal P16 = 1)

c2

12

10

11

PREHEAT, ALARM

CONF.OUT
HORN

REMOTE START SIGNAL

STARTER

CONF. INPUT-1

CHARGE
GEN. D+(W.L.)

HIGH TEMPERATURE

40 A

40 A

START
RELAY

+
BATTERY

LOW OIL PRESSURE

FUSE-1

SOLENOID
RELAY
B+

OR LOAD CONTACTOR

CHARGE
GENERATOR

+BAT

-BAT

8
+BAT

10A@28VDC

10A@28VDC

13

10A@28VDC

N
L1

FUSE-2

ALTERNATOR

BATTERY NEGATIVE MUST BE GROUNDED

The fuses should be as follows:


FUSE-1
According to current required by solenoids (Max. 16A. T)
FUSE-2
Max. 1A. T

1- Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and
battery negative should be grounded.
2- Use Alternator connection only generator application (P00 = Gen)

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Connection Schematic (With Remote Start, No Power Consumption P16 = 2)

c2

12

10

11

CONF.OUT

STARTER

HORN

CONF. INPUT-2

CHARGE
GEN. D+(W.L.)

CONF. INPUT-1

HIGH TEMPERATURE

40 A

START
RELAY

40 A

SOLENOID
RELAY
B+

BATTERY

LOW OIL PRESSURE

CHARGE
GENERATOR

REMOTE
SWITCH

OR LOAD CONTACTOR

+BAT

FUSE-1

-BAT

+BAT

PREHEAT, ALARM

10A@28VDC

10A@28VDC

13

10A@28VDC

N
L1

FUSE-2

ALTERNATOR

BATTERY NEGATIVE MUST BE GROUNDED

The fuses should be as follows:


FUSE-1
According to current required by solenoids (Max. 16A. T)
FUSE-2
Max. 1A. T

1- Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and
battery negative should be grounded.
2- Use Alternator connection only generator application (P00 = Gen)

Connection Schematic (For Fail Safe)

c2

12

10

11

PREHEAT, ALARM

CONF.OUT
HORN

CONF. INPUT-2

STARTER

CONF. INPUT-1

CHARGE
GEN. D+(W.L.)

HIGH TEMPERATURE

40 A

40 A

START
RELAY

+
BATTERY

LOW OIL PRESSURE

FUSE-1

SOLENOID
RELAY
B+

OR LOAD CONTACTOR

CHARGE
GENERATOR

+BAT

-BAT

8
+BAT

10A@28VDC

10A@28VDC

13

10A@28VDC

N
L1

FUSE-2

ALTERNATOR

BATTERY NEGATIVE MUST BE GROUNDED

The fuses should be as follows:


FUSE-1
According to current required by solenoids (Max. 16A. T)
FUSE-2
Max. 1A. T

1- Connect the unit as shown in the appropriate diagram above. Be sure to connect the battery supply the right way round and
battery negative should be grounded.
2- Use Alternator connection only generator application (P00 = Gen)

Product Codes
Manual and Remote Start Unit with Key Switch, 72x72 DIN Size, with relay outputs
EAOM-36.R
EAOM-36.RF Manual and Remote Start Unit with Key Switch, 72x72 DIN Size, with relay outputs & fail safe inputs

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Other Informations
Manufacturer Information:
Emko Elektronik Sanayi ve Ticaret A..
Demirta Organize Sanayi Blgesi Karanfil Sk. No:6 16369
BURSA/TURKEY
Phone : +90 224 261 1900
Fax : +90 224 261 1912
Repair and Maintenance Service Information:
Emko Elektronik Sanayi ve Ticaret A..
Demirta Organize Sanayi Blgesi Karanfil Sk. No:6 16369
BURSA/TURKEY
Phone : +90 224 261 1900
Fax : +90 224 261 1912

Thank you very much for your preference to use Emko Elektronik
Your Technology Partner

Products.

www.emkoelektronik.com.tr

Anda mungkin juga menyukai