Heating/Cooling
(1) Warm air enters and refrigerant takes the heat from the air via evaporator . Cooler air exists.
(2) Refrigerant become gas with high temperature and high pressure when compressed by compressor,
(3)Cool water enters from the water tank. Refrigerant transfers the heat into water via condenser . Warmer water exists back to the tank.
(4)Refrigerant pressure and temperature decreases via the expansion valve, ready to re start the whole cycle.
Models
DE-13W/CY
DE-18W/CY
DE-27W/CY
DE-36W/CY
DE-46W/CY
DE-27W/DY
DE-46W/DY
DE-52W/DY
DE-75W/DY
DE-92W/DY
DE-105W/DY
DE-150W/DY
DE-180W/DY
Product Description
21.0
30.0
39.0
46.5
55.0
76.0
Performance Data:
Model
Tw(
28
DE-18W/CY
DE-27W/CY
DE-46W/DY
DE-92W/DY
Ta( )
Pi(W)
Hc(W)
COP
Pi(W)
Hc(W)
COP
Pi(W)
Hc(W)
COP
Pi(W)
Hc(W)
COP
1337.17
6151
4.6
2193.78
9872.00
4.5
3544.22
15949.00
4.5
8450.30
38784.50
4.6
10
1358.54
6521
4.8
2177.92
10454.00
4.8
3574.47
16800.00
4.7
8518.10
39787.10
4.7
15
1330.58
6919
5.2
2151.37
10972.00
5.1
3431.37
17500.00
5.1
8169.60
40378.30
20
1325.93
7160
5.4
2134.15
11311.00
5.3
3435.85
18210.00
5.3
8277.96
40638.73
5.1
25
1424.64
7978
5.6
2203.27
12118.00
5.5
3678.57
20600.00
5.6
8558.30
47763.60
5.5
Items
Case
DERON DE-13W/CY
High temperature coated steel or 304#
stainless steel case.
Other Suppers
Compressor
Panasonic
like
Panasonic-2P20C225CUA/2P21S225AUS;
Hitachi-SL211SV
shape
resistance
shape
exchanger rate
Evaporator
Heat exchanger
Expansion valve
Emerson
Four-way valve
Saginomiya
Pressure switch
Controller
Galvanized iron
Inspection before
delivery
10
Random inspection
Installation note:
1. At all times only let swimming pool water through the heat pump which has the correct chemical balance.
Chlorine not to exceed 3 ppm
pH between 7.2 and 7.7
Total Alkalinity 90 150 ppm
Calcium Hardness 100 400 ppm
2. When it is decided to close down the swimming pool for the winter it is important that the heat pump be immediately emptied of water.
3. Ensure that pool water can not freely flow out of the pool and then loosen both coupling nuts to the pipe work and withdraw the pipes from the heat pump.
4. Drain all the water from the heat pump.
5. Also empty the pipes.
6. The heat pump warranty does not cover frost damage.
7. The heat pump may be left outside all the year round but if you do have some room for the heat pump in a shed or garage, this will be a perfect place to
keep it for the winter
period.
8. You may wish to cover the heat pump to protect it from the worst weather conditions but do not wrap up the unit too tightly, let air circulate around it.
9. Do not lay the heat pump on its side, always store upright.
CE Certificate
Show room
National-state labs
Monitoring equipments
CNC center