Manual Call Points

www.boschsecurity.com

7
LSN Manual Call Points

226

Conventional Manual Call Points

237

Accessories - Manual Call Points LSN and


Conventional

246

Conventional Manual Call Points for Ex


Areas

249

Accessories - Manual Call Points for Ex


Areas

251

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

226 | Manual Call Points | LSN Manual Call Points

FMC420RW Single Action


Call Points LSN improved

Pressing the black marking (1) breaks the glass pane (3),
which triggers the alarm and causes the LED display (2) to
flash.
Single action call points can be reset with the test key and
by replacing the glass pane (3). The LED display (2) goes
out.
Resettable single action call points:

4
1

7
Features

Pressing the black marking (1) triggers the alarm. The alarm
status is displayed by the red window (4) and the flashing
LED display (2).

Alarm triggering by pressing the black marking or


breaking the glass pane

Single action call points can be reset using the test key. The
LED display (2) goes out.

Protection against injury through foil-labeled glass


pane

Individual call point identification

LED display for triggered alarm or inspection


evaluation
Individual call point identification
Call point query routines with evaluation and multiple
transmission
Maintains LSN loop functions in the event of wire
interruption or short-circuit thanks to two integrated
isolators

FMC420RW Single Action Call Points are used for manual


alarm triggering and can be employed in both the Local
SecurityNetwork (LSN) and the LSN improved version.

Neither single action call points with glass pane nor


resettable single action call points are reset on the fire
panel.
Individual call point identification with display of the call
point address on the fire panel ensures the quick location
of the triggered call point.

Certifications and Approvals


Region

Certification

Europe

CPD

0786-CPD-20333 FMC-420RW

Germany

VdS

G 207087 FMC-420RW

Installation/Configuration Notes

Functions

Single action call points with glass pane:

Bosch Security Systems B.V.

Manual call points must be mounted visibly along


escape and rescue routes (e.g. exits, passageways,
stairwells) and be easily accessible.
An installation height of 1400 mm 200 mm (55 in. 8
in.), measured from the middle of the manual call point
to the floor, must be maintained.
Manual call points must be sufficiently lit with daylight
or another light source (including emergency lighting if
present).
The maximum number of LSN elements that can be
connected depends on their current consumption from
the LSN data line. The limit values should be taken from
the product information supplied with the fire panel
used.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | LSN Manual Call Points | 227

Standards, guidelines and planning recommendations


regarding the installation location etc. should also be
taken into consideration.
The regulations of the local fire services must be
observed.

Ordering Information
FMC420RWGSGRD Manual Call Point with
Glass Pane, Red
Surface-mounted

FMC-420RWGSGRD
FMC-420RWGSRRD

Parts Included

FMC420RWGSRRD Manual Call Point


Resettable, Red
Surface-mounted

Quanti- Components
ty

FMC420RWGFGRD Manual Call Point with


Glass Pane, Flush-mounted, Red
Flush-mounted

FMC-420RWGFGRD

FMC420RWGFRRD Manual Call Point


Resettable, Flush-mounted, Red
Flush-mounted

FMC-420RWGFRRD

FMC420RWGSGYE Manual Call Point with


Glass Pane, Yellow
Surface-mounted

FMC-420RWGSGYE

FMC420RWGSRYE Manual Call Point


Resettable, Yellow
Surface-mounted

FMC-420RWGSRYE

FMC420RWGSGBU Manual Call Point with


Glass Pane, Blue
Surface-mounted

FMC-420RWGSGBU

FMC420RWGSRBU Manual Call Point


Resettable, Blue
Surface-mounted

FMC-420RWGSRBU

FMC-420RW-GSGRD Manual Call Point with Glass Pane, Surfacemounted, Red

FMC-420RW-GSRRD Manual Call Point Resettable, Surfacemounted, Red

FMC-420RW-GFGRD Manual Call Point with Glass Pane, Flushmounted, Red

FMC-420RW-GFRRD Manual Call Point Resettable, Flush-mounted, Red

FMC-420RW-GSGYE Manual Call Point with Glass Pane, Surfacemounted, Yellow

FMC-420RW-GSRYE Manual Call Point Resettable, Surfacemounted, Yellow

FMC-420RW-GSGBU Manual Call Point with Glass Pane, Surfacemounted, Blue

FMC-420RW-GSRBU Manual Call Point Resettable, Surfacemounted, Blue

Note

The FMCKEYRW Test Key is not included in


the scope of delivery and must be ordered
separately.

Technical Specifications
Electrical
Operating voltage

15 VDC to 33 VDC

Current consumption

0.4 mA

Mechanical components
Dimensions (H x W x D)

FMC420RWGFGRD,
FMC420RWGFRRD

107 mm x 107 mm x 38.5 mm (4.2


in. x 4.2 in. x 1.5 in.)

FMC420RWGSGRD,
FMC420RWGSGBU,
FMC420RWGSGYE

87 mm x 87 mm x 56 mm (3.4 in. x
3.4 in. x 2.2 in.)

FMC420RWGSRRD,
FMC420RWGSRBU,
FMC420RWGSRYE

87 mm x 87 mm x 56 mm (3.4 in. x
3.4 in. x 2.2 in.)

Housing material

Accessories
FMCSPACERRWRD Spacer, Red
For the flush-mounted variant of the RW call
points. Its use increases the storage room for
the cables.
1 unit = 5 spacers

FMC-SPACERRWRD

FMCSPGLRW Spare Glasses


Spare glasses for all RW call points.
1 unit = 5 spare glasses

FMC-SPGL-RW

FMCSIGNRW Out of Order Sign


Used instead of the glass pane when a call point
is not ready for use.
1 unit = 5 signs

FMC-SIGN-RW

FMCKEYRW Test Key


The key can open, check, and reset manual call
points.
1 unit = 1 key

FMC-KEY-RW

FMCFLAPRW Clear Hinged Flap


To protect against accidental triggering; with
seal.
1 unit = 5 flaps

FMC-FLAP-RW

Plastic, ASA

Colors

Red

RAL 3001

Blue

RAL 5005

Yellow

RAL 1003

Environmental conditions
Protection category according to
EN 60529

IP 52

Permissible operating temperature -25 C to +70 C

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

228 | Manual Call Points | LSN Manual Call Points

FMC-420RW Single Action Call Points LSN improved version

Design

FMC-420RW-GSGRD

FMC-420RW-GSRRD

FMC-420RW-GFGRD

FMC-420RW-GFRRD

with glass pane

resettable

with glass pane

resettable

indoor

indoor

indoor

indoor

surface-mounted

surface-mounted

flush-mounted

flush-mounted

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

0.4 mA

0.4 mA

0.4 mA

0.4 mA

Range of use
Mounting
Operating voltage
Current consumption

IP 52

IP 52

IP 52

IP 52

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

red, RAL 3001

red, RAL 3001

red, RAL 3001

red, RAL 3001

Protection category

Permissible operating temperature


Color

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | LSN Manual Call Points | 229

FMC-420RW Single Action Call Points LSN improved version

Design
Range of use
Mounting
Operating voltage
Current consumption

FMC-420RW-GSGYE

FMC-420RW-GSRYE

FMC-420RW-GSGBU

FMC-420RW-GSRBU

with glass pane

resettable

with glass pane

resettable

indoor

indoor

indoor

indoor

surface-mounted

surface-mounted

surface-mounted

surface-mounted

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

0.4 mA

0.4 mA

0.4 mA

0.4 mA

IP 52

IP 52

IP 52

IP 52

Permissible operating temperature

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

Color

yellow, RAL 1003

yellow, RAL 1003

blue, RAL 5005

blue, RAL 5005

Protection category

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

230 | Manual Call Points | LSN Manual Call Points

FMC210DM Manual Call


Points

In the event of an alarm, the glass pane (2) is broken first,


then the manual call point (3) is pressed hard. This activates
the microswitch for alarm triggering and the indicator LED
(4) blinks. A mechanism holds the pressed call point down.
The manual call point can be reset with the reset lever (5)
or by closing the door of the manual call point (1). The
indicator LED (4) goes out.
This does not reset the alarm on the fire panel.
Individual call point identification with display of the call
point address on the fire panel ensures the quick location
of the triggered call point.
Variants
The designs of the manual call points for outdoor and indoor
use are identical. The manual call points for indoor use
(form G) are available in red, blue, and yellow; the manual
call points for outdoor use (form H) are available in red and
blue.

Form H manual call points are equipped with an especially


resistant PC board layered with parylene.
Improved LSN features
The manual call points offer all the features of the improved
LSN technology:

Features
Adjustment of the Manual Call Point after alarm
triggering

Automatic or manual detector addressing via rotary


switch possible

Indicator LED for alarm or for inspection evaluation


Call point query routines with evaluation and multiple
transmission
Individual call point identification
Maintains LSN loop functions in the event of wire
interruption or short-circuit thanks to two integrated
isolators

Flexible network structures, including "T-tapping"


without additional elements
Up to 254 LSN improved elements per loop or stub line
Automatic or manual detector addressing selectable via
rotary switch, in each case with or without autodetection
Power supply for connected elements via LSN bus up to
300 mA
Shielded and unshielded cables can be used
Cable length up to 1000 m
Downwards compatibility to existing LSN systems and
control panels.

Certifications and Approvals


The FMC210DM Manual Call Points are used to trigger the
alarm manually, and are deployed in the Local
SecurityNetwork LSN and LSN improved. Form H Manual
Call Points are designed for outdoor deployment, form G
Manual Call Points are designed for indoor deployment.

Region

Certification

Europe

CE

FMC-210-DM-G-B / -H-B / -SM-G-B


FMC-210-DM-G-R / -H-R / -SM-G-R
FMC-210-DM-G-Y / EST-G-B

CPD

0786-CPD-20293 FMC-210-DM-G/H-R
0786-CPD-20244 FMC-210-DM-G-Y

Functions

0786-CPD-20245 FMC-210-EST-G-B

5
1

Germany

VdS

G 206100 FMC-210-EST-G-B
G 206098 FMC-210-DM-G-R /-G-R-A/ -HR

G 206099 FMC-210-DM-G-Y
3

Bosch Security Systems B.V.

Poland

CNBOP

0082/2008 FMC-210 DM-G-R, FMC-210


DM-H-R

Czech
Republic

TZS

080_12987 FMC-210

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | LSN Manual Call Points | 231

Region

Certification

Russia

GOST

POCC DE.C313.B06297

Slovakia

EVP

SK08-ZSV-0071 FMC-210-DM,
FMC-210-EST

Type Number

Complies with

FMC210DMGR

EN 54-11:2001/A1:2005, EN 54-17:2005

FMC210DMHR

EN 54-11:2001/A1:2005, EN 54-17:2005

FMC210DMGY

EN 12094-3:2003, EN 54-17:2005

FMC210ESTGB

EN 12094-3:2003, EN 54-17:2005

135 mm
2,5 mm

140 mm
2 mm

12,5 mm

Installation/Configuration Notes

Manual call points must be mounted visibly along


escape and rescue routes (e.g. exits, passageways,
stairwells) and be easily accessible.
An installation height of 1400 mm 200 mm, measured
from the middle of the manual call point to the floor,
must be maintained.
Manual call points must be adequately illuminated by
sunlight or another light source (including emergency
lighting if present).
The maximum number of LSN elements that may be
connected depends on their current consumption from
the LSN data line. The limit values should be taken from
the product information supplied with the fire panel
used.
Additional norms, guidelines, and planning
recommendations with respect to installation location,
etc. must be taken into account (see fire detector
manual).
The regulations of the local fire services must be
observed.

Installation
The cable duct can be surface-mounted or flushmounted.

149,5 mm

7
139 mm

Pos.

Description

Installation depth version 1: ca. 40 mm

Installation depth version 2: 14 mm

Installation depth version 3: min. 30 mm

Parts Included

Installation in fire hose cabinets is possible in three


ways:

Type Number

Component

FMC210DMGR
Form G, Red

Manual Call Point for indoor use, indirect triggering


(type B), housing color red

FMC210DMHR
Form H, Red

Manual Call Point for outdoor use, indirect triggering


(type B) , housing color red

FMC210DMGB
Form G, Blue

Manual Call Point for indoor use, indirect triggering


(type B), housing color blue

FMC210DMHB
Form H, Blue

Manual Call Point for outdoor use, indirect triggering


(type B), housing color blue

FMC210DMGY
Form G, Yellow

Manual Call Point for indoor use, indirect triggering


(type B), housing color yellow

FMC210ESTGB
Form G, Blue

Electronic Stop Device for indoor use, indirect triggering (type B), housing color blue

Note

www.boschsecurity.com

The key must be ordered separately.

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

232 | Manual Call Points | LSN Manual Call Points

Technical Specifications

Ordering Information

Electrical

Accessories

Operating voltage

24 V DC (15 V DC . . . 33 V DC)

Current consumption

0.4 mA

Mechanics
Dimensions (W x H x D)

135 x 135 x 40 mm /
5.31 x 5.31 x 1.5 in.

Housing material

Plastic, ASA

Colors

Red, RAL 3001


Blue, RAL 5005
Yellow, RAL 1003

Weight

Approx. 235 g

Environmental Considerations
Protection class as per EN 60529

Form H (outdoor use)

IP 54

Form G (indoor use)

IP 52

FMC210DMGR,
FMC210DMHR

EN 54-11

FMC210DMGY,
FMC210ESTGB

EN 12094-3

FMXFSOLSN Punched, Self-adhesive Foil


Sets (Blank)
For the labeling field of manual call points of
the Series FMC210.
1 unit = 10 sheets

FMX-FSO-LSN

FMCFSTDE Printed Labeling Foils for the


Upper Label Field
For yellow and blue manual call points of Series
FMC120 and FMC210, 1 unit = 5 sheets

FMC-FST-DE

FMCSPGLDEIL Spare Glasses


For manual call points of Series DM, DKM, SKM,
FMC120 and FMC210.
1 unit = 5 spare glasses

FMC-SPGL-DEIL

Sign with label "Nicht in Betrieb"


Metal sign for fire detectors form G or H

FMM-SIGN

Key for Fire Detectors Types G and H


made of red plastic (ASA)

FMM-KEY-Form G/H

Norm

Permissible operating temperature

Form H (outdoor use)

-25 C . . . +70 C /
-13 F 158 F

Form G (indoor use)

-10 C . . . +55 C /
14 F 131 F

Ordering Information
FMC210DMGR Form G, Red
Manual call point for indoor use, indirect triggering (type B)

FMC-210-DM-G-R

FMC210DMHR Form H, Red


Manual call point for outdoor use, indirect triggering (type B)

FMC-210-DM-H-R

FMC210DMGB Form G, Blue


Manual call point for indoor use, indirect triggering (type B)

FMC-210-DM-G-B

FMC210DMHB Form H, Blue


Manual call point for outdoor use, indirect triggering (type B)

FMC-210-DM-H-B

FMC210DMGY Form G, Yellow


Manual call point for indoor use, indirect triggering (type B)

FMC-210-DM-G-Y

FMC210ESTGB Form G, Blue


Electronic stop device for indoor use, indirect
triggering (type B)

FMC-210-EST-G-B

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | LSN Manual Call Points | 233

FMC-210-DM Single Action Call Points

FMC-210-DM-G-R

FMC-210-DM-H-R

FMC-210-DM-G-B

indoor

outdoor

indoor

surface-mounted/flushmounted

surface-mounted/flushmounted

surface-mounted/flushmounted

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

Current consumption

0.4 mA

0.4 mA

0.4 mA

Protection category

IP 52

IP 54

IP 52

-10C . . . +55C

-25C . . . +70C

-10C . . . +55C

red, RAL 3001

red, RAL 3001

blue, RAL 5005

Range of use
Mounting
Operating voltage

Permissible operating temperature


Color

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

234 | Manual Call Points | LSN Manual Call Points

FMC-210-DM Single Action Call Points

FMC-210-DM-H-B

FMC-210-DM-G-Y

FMC-210-EST-G-B

outdoor

indoor

indoor

surface-mounted/flushmounted

surface-mounted/flushmounted

surface-mounted/flushmounted

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

15 V DC . . . 33 V DC

Current consumption

0.4 mA

0.4 mA

0.4 mA

Protection category

IP 54

IP 52

IP 52

Permissible operating temperature

-25C . . . +70C

-10C . . . +55C

-10C . . . +55C

Color

blue, RAL 5005

yellow, RAL 1003

blue, RAL 5005

Range of use
Mounting
Operating voltage

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | LSN Manual Call Points | 235

FMC210SM Single Action


Call Points

The call point (3) can be reset after inserting a new glass
pane (2) and closing the door of the single action call point
(1). The indicator LED (4) goes out.
This does not reset the alarm on the fire panel.
Individual call point identification with display of the call
point address on the fire panel ensures the quick location
of the triggered call point.

Certifications and Approvals


FMC210SMGR applies to

EN 5411:2001/A1:2005
EN 5417:2005

Region

Certification

Europe

CPD

0786-CPD-20316 FMC-210-SM-G-R

Germany

VdS

G 207008 FMC-210-SM-G-R

Installation/Configuration Notes

Features
Alarm triggering by breaking of the glass pane
Automatic or manual detector addressing via rotary
switch possible
Indicator LED for alarm or for inspection evaluation
Call point query routines with evaluation and multiple
transmission

Individual call point identification


Maintains LSN loop functions in the event of wire
interruption or short-circuit thanks to two integrated
isolators

The FMC210SM Single Action Call Points are used to


trigger the alarm manually, and can be used in the Local
SecurityNetwork LSN and LSN improved. The FMC210SM
Single Action Call Points are designed for indoor
deployment.

Functions
5
1

Manual call points must be mounted visibly along


escape and rescue routes (e. g. exits, passageways,
stairwells) and be easily accessible.
An installation height of 1400 mm 200 mm, measured
from the middle of the manual call point to the floor,
must be maintained.
Manual call points must be adequately illuminated by
sunlight or another light source (including emergency
lighting if present).
The maximum number of LSN elements that may be
connected depends on their current consumption from
the LSN data line. The limit values should be taken from
the product information supplied with the fire panel
used.
Further standards, guidelines and planning
recommendations regarding the installation location
etc., should also be taken into consideration (see Fire
Detection manual).
The regulations of the local fire services must be
observed.

Installation notes in accordance with VdS/VDE


The distance between manual call points should not be
more than 100 m according to DIN 14675 or 80 m
according to VdS.
In high risk areas, manual call points should be installed
at a distance of max. 40 m (VDE 0833 Part 2,
Point 7.2.6).
Installation
The cable duct can be surface-mounted or flushmounted.

With single action call points, the alarm is triggered when


the glass plate (2) is broken and the button (3) springs up.
This activates the microswitch for alarm triggering and the
indicator LED (4) blinks.

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

236 | Manual Call Points | LSN Manual Call Points

Technical Specifications
Electrical
Operating voltage

15 V DC . . . 33 V DC

Current consumption

0.4 mA

Mechanics

Installation in fire hose cabinets is possible in three


ways:

Dimensions (H x W x D)

135 x 135 x 40 mm

Housing material

Plastic, ASA

Colors

FMC-210-SM-G-R

Red, RAL 3001

FMC-210-SM-G-B

Blue, RAL 5005

Weight

Approx. 235 g

Environmental Considerations

135 mm
2,5 mm

Protection class as per EN 60529

IP 52

Permissible operating temperature -10 C. . . +55

Ordering Information

140 mm
2 mm

12,5 mm

149,5 mm

FMC210SMGR Form G, Red


Single Action Call Point for indoor use, direct
triggering (type A)

FMC-210-SM-G-R

FMC210SMGB Form G, Blue


Single Action Call Point for indoor use, direct
triggering (type A)

FMC-210-SM-G-B

139 mm

Accessories

Pos.

Description

Installation depth version 1: ca. 40 mm

Installation depth version 2: 14 mm

Installation depth version 3: min. 30 mm

Parts Included
TypeNumber.

Component

FMC210SMGB
Form G, Blue

Single Action Call Point for indoor use, direct triggering (type A)

FMC210SMGR
Form G, Red

Single Action Call Point for indoor use, direct triggering (type A

Note

FMXFSOLSN Punched, Self-adhesive Foil


Sets (Blank)
For the labeling field of manual call points of
the Series FMC210.
1 unit = 10 sheets

FMX-FSO-LSN

FMCFSTDE Printed Labeling Foils for the


Upper Label Field
For yellow and blue manual call points of Series
FMC120 and FMC210, 1 unit = 5 sheets

FMC-FST-DE

FMCSPGLDEIL Spare Glasses


For manual call points of Series DM, DKM, SKM,
FMC120 and FMC210.
1 unit = 5 spare glasses

FMC-SPGL-DEIL

Key for Fire Detectors Types G and H


made of red plastic (ASA)

FMM-KEY-Form G/H

Sign with label "Nicht in Betrieb"


Metal sign for fire detectors form G or H

FMM-SIGN

The key must be ordered separately.

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points | 237

FMC300RW Single Action


Call Points

Resettable single action call points:

4
1

Pressing the black marking (1) triggers the alarm. The alarm
status is displayed by the red window (4) and the flashing
LED display (2).
Single action call points can be reset using the test key. The
LED display (2) goes out.

Certifications and Approvals


Features

Applies to EN 5411:2001/A1:2005

Alarm triggering by pressing the black marking or


breaking the glass pane

Region

Certification

Europe

CPD

0786-CPD-20332 FMC-300RW

Germany

VdS

G 207086 FMC-300 RW

Protection against injury through foil-labeled glass


pane
LED display for triggered alarm or inspection
evaluation

Installation/Configuration Notes
FMC300RW Single Action Call Points are used for manual
alarm triggering and are employed in conventional
technology.

Functions

Single action call points with glass pane:

Manual call points must be mounted visibly along


escape and rescue routes (e.g. exits, passageways,
stairwells) and be easily accessible.
An installation height of 1400 mm 200 mm (55 in. 8
in.), measured from the middle of the manual call point
to the floor, must be maintained.
Manual call points must be sufficiently lit with daylight
or another light source (including emergency lighting if
present).
The maximum number of LSN elements that can be
connected depends on their current consumption from
the LSN data line. The limit values should be taken from
the product information supplied with the fire panel
used.
Standards, guidelines and planning recommendations
regarding the installation location etc. should also be
taken into consideration.
The regulations of the local fire services must be
observed.

Pressing the black marking (1) breaks the glass pane (3),
which triggers the alarm and causes the LED display (2) to
flash.
Single action call points can be reset with the test key and
by replacing the glass pane (3). The LED display (2) goes
out.

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

238 | Manual Call Points | Conventional Manual Call Points

Ordering Information

Parts Included

Accessories

Quanti- Components
ty
1

FMC-300RW-GSGBU Manual Call Point with Glass Pane, Blue

FMC-300RW-GSRBU Manual Call Point Resettable, Blue

FMC-300RW-GSGRD Manual Call Point with Glass Pane, Red

FMC-300RW-GSRRD Manual Call Point Resettable, Red

FMC-300RW-GSGYE Manual Call Point with Glass Pane, Yellow

FMC-300RW-GSRYE Manual Call Point Resettable, Yellow

Note

The FMCKEYRW Test Key is not included in


the scope of delivery and must be ordered
separately.

Technical Specifications

Electrical
Operating voltage

20 VDC
(8.5 VDC to 30 VDC)

Current consumption

specified by the respective security


system

Alarm resistor

820 +/- 10%


(8.5 VDC to 30 VDC)

FMCSPACERRWRD Spacer, Red


For the flush-mounted variant of the RW call
points. Its use increases the storage room for
the cables.
1 unit = 5 spacers

FMC-SPACERRWRD

FMCSPGLRW Spare Glasses


Spare glasses for all RW call points.
1 unit = 5 spare glasses

FMC-SPGL-RW

FMCSIGNRW Out of Order Sign


Used instead of the glass pane when a call point
is not ready for use.
1 unit = 5 signs

FMC-SIGN-RW

FMCKEYRW Test Key


The key can open, check, and reset manual call
points.
1 unit = 1 key

FMC-KEY-RW

FMCFLAPRW Clear Hinged Flap


To protect against accidental triggering; with
seal.
1 unit = 5 flaps

FMC-FLAP-RW

Mechanical components
Dimensions (H x W x D)

87 mm x 87 mm x 56 mm (3.4 in. x
3.4 in. x 2.2 in.)

Housing material

Plastic, ASA

Colors

Red

RAL 3001

Blue

RAL 5005

Yellow

RAL 1003

Environmental conditions
Protection category according to EN IP 52
60529
Permissible operating temperature -25 C to +70 C

Ordering Information
FMC300RWGSGBU Manual Call Point with
Glass Pane, Blue

FMC-300RWGSGBU

FMC300RWGSRBU Manual Call Point


Resettable, Blue

FMC-300RWGSRBU

FMC300RWGSGRD Manual Call Point with


Glass Pane, Red

FMC-300RWGSGRD

FMC300RWGSRRD Manual Call Point


Resettable, Red

FMC-300RWGSRRD

FMC300RWGSGYE Manual Call Point with


Glass Pane, Yellow

FMC-300RWGSGYE

FMC300RWGSRYE Manual Call Point


Resettable, Yellow

FMC-300RWGSRYE

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points | 239

FMC-300RW Single Action Call Points

Design
Range of use
Mounting
Operating voltage
Current consumption

FMC-300RW-GSGBU

FMC-300RW-GSRBU

FMC-300RW-GSGRD

with glass pane

resettable

with glass pane

indoor

indoor

indoor

surface-mounted

surface-mounted

surface-mounted

8.5 V DC . . . 30 V DC

8.5 V DC . . . 30 V DC

8.5 V DC . . . 30 V DC

specified by the respective se- specified by the respective se- specified by the respective security system
curity system
curity system
IP 52

IP 52

IP 52

Permissible operating temperature

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

Color

blue, RAL 5005

blue, RAL 5005

red, RAL 3001

Protection category

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

240 | Manual Call Points | Conventional Manual Call Points

FMC-300RW Single Action Call Points

Design
Range of use
Mounting
Operating voltage
Current consumption
Protection category

Permissible operating temperature


Color

Bosch Security Systems B.V.

FMC-300RW-GSRRD

FMC-300RW-GSGYE

FMC-300RW-GSRYE

resettable

with glass pane

resettable

indoor

indoor

indoor

surface-mounted

surface-mounted

surface-mounted

8.5 V DC . . . 30 V DC

8.5 V DC . . . 30 V DC

8.5 V DC . . . 30 V DC

specified by the respective se- specified by the respective se- specified by the respective security system
curity system
curity system
IP 52

IP 52

IP 52

-25C . . . +70C

-25C . . . +70C

-25C . . . +70C

red, RAL 3001

yellow, RAL 1003

yellow, RAL 1003

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points | 241

FMC120DKM Manual Call


Points

Variants
The design of the manual call points for indoor (form G) and
outdoor use (form H) are identical. Three color variants,
red, blue, and yellow are available.
Detectors for outdoor use (form H) have a cover equipped
with a seal.

Certifications and Approvals


Region

Certification

Europe

CE

FMC-120-EST-G-B / -DKM-G-Y
FMC-120-DKM-G-R / -H-R
FMC-120-DKM-G-B

CPD

0786-CPD-20294 FMC-120-DKM-G/H-R
0786-CPD-20231 FMC-120-DKM-G-Y
0786-CPD-20232 FMC-120-EST-G-B/H-HE

Germany

VdS

G 298061 FMC-120-DKM-G-R / -H-R


G 206079 FMC-120-DKM-G-Y

Features

G 206080 FMC-120-EST-G-B

Adjustment of the manual call point after alarm


triggering

PTB

Indicator LED for alarm or for inspection evaluation


Second contact with connections for panel control

01 ATEX 2163 X OTC/OC 310/410, OT/


O/T 300/400, DKM/SKM 120, DM/SM
210, MPA
01 ATEX 2163 X FMC-120-DKM

Variants for indoor and outdoor use

Russia

The FMC-120-DKM Manual Call Points handle manual alarm


triggering and are used with conventional technology.

GOST

POCC DE.C313.B06297

Type Number

Complies with

FMC120DKMGR

EN54-11:2001/A1:2005

FMC120DKMHR

EN54-11:2001/A1:2005

FMC120DKMGY

EN12094-3:2003

FMC120ESTGB

EN12094-3:2003

Functions
5
1

Installation/Configuration Notes

In the event of an alarm, the glass pane (2) is broken first,


then the manual call point (3) is pressed hard.

This activates the micro switch for alarm triggering and the
indicator LED (4) blinks.

A locking mechanism holds the pressed manual call point.


The manual call point can be reset with the reset lever (5).
The indicator LED (4) goes out.
This does not reset the alarm on the fire panel.

www.boschsecurity.com

Manual call points have to be mounted visibly along


escape and rescue routes (e.g. exits, passageways,
stairwells) and be easily accessible.
An installation height of 1400 mm 200 mm, measured
from the middle of the manual call point to the floor,
must be maintained.
Manual call points must be illuminated sufficiently with
daylight or another light source (including emergency
lighting, if present).
Max. one test detector may be used for primary lines
together with automatic detectors. The test detector is
connected at the end of the primary line.
Further standards, guidelines and planning
recommendations regarding the installation location
etc., should also be taken into consideration (see Fire
Detection manual).
Regulations of local fire departments must be observed.

Installation
Cables can be inserted surface-mounted or flushmounted.

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

242 | Manual Call Points | Conventional Manual Call Points

Mechanics

3,4

Dimensions (W x H x D)

135 x 135 x 37 mm /
5.31 x 5.31 x 1.4 in.

Housing material

Plastic (ASA)

Colors

Red, RAL 3001


Blue, RAL 5005
Yellow, RAL 1003

Weight

Approx. 224 g

Environmental conditions

Installation in fire hose cabinets is possible in three


ways:

Form G (indoor area)

IP 52

Form H (outdoor area)

IP 54

Norm
135
2,5

Protection class as per EN 60529

FMC-120-DKM-G-R,
FMC120DKMHR

EN 54-11

FMC-120-DKM-G-Y,
FMC120ESTGB

EN 12094-3

Permissible operating temperature

140

Form G (indoor area)

-10 C . . . +55 C /
14 F 131 F

Form H (outdoor area)

-25 C . . . +70 C /
-13 F 158 F

10

Ordering Information

139

147

Pos.

Description

Installation depth version 1: 36 mm

Installation depth version 2: 14 mm

Installation depth version 3: approx. 30 mm

Technical Specifications
Electrical
Operating voltage

24 V DC (16.2 V DC . . . 30 V DC)

Current consumption

Specified by the respective security


system

Bosch Security Systems B.V.

FMC120DKMGR Form G, Red


Conventional Manual Call Point for indoor use,
indirect triggering (type B)

FMC-120-DKM-G-R

FMC120DKMHR Form H, Red


Conventional Manual Call Point for outdoor
use, indirect triggering (type B)

FMC-120-DKM-H-R

FMC120DKMGB Form G, Blue


Conventional Manual Call Point for indoor use,
indirect triggering (type B)

FMC-120-DKM-G-B

FMC120DKMHB Form H, Blue


Conventional Manual Call Point for outdoor
use, indirect triggering (type B)

FMC-120-DKM-H-B

FMC120DKMGY Form G, Yellow


Conventional Manual Call Point for indoor use,
indirect triggering (type B)

FMC-120-DKM-G-Y

FMC120ESTGB Form G, Blue


Conventional Electronic Stop Device for indoor
use, indirect triggering (type B)

FMC-120-EST-G-B

Accessories
FMXFSOGLT Punched, Self-adhesive Foil
Sets (Blank)
For the labeling field of conventional manual
call points of the Series FMC120,
1 unit = 10 sheets

FMX-FSO-GLT

FMCFSTDE Printed Labeling Foils for the


Upper Label Field
For yellow and blue manual call points of Series
FMC120 and FMC210, 1 unit = 5 sheets

FMC-FST-DE

FMCSPGLDEIL Spare Glasses


For manual call points of Series DM, DKM, SKM,
FMC120 and FMC210.
1 unit = 5 spare glasses

FMC-SPGL-DEIL

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points | 243

Ordering Information
Sign with label "Nicht in Betrieb"
Metal sign for fire detectors form G or H

FMM-SIGN

Key for Fire Detectors Types G and H


made of red plastic (ASA)

FMM-KEY-Form G/H

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

244 | Manual Call Points | Conventional Manual Call Points

FMC-120-DKM Single Action Call Points

FMC-120-DKM-G-R

FMC-120-DKM-H-R

FMC-120-DKM-G-B

indoor

outdoor

indoor

Mounting

surface-mounted/flushmounted

surface-mounted/flushmounted

surface-mounted/flushmounted

Operating voltage

16.2 V DC . . . 30 V DC

16.2 V DC . . . 30 V DC

16.2 V DC . . . 30 V DC

Range of use

Current consumption
Protection category

Permissible operating temperature


Color

Bosch Security Systems B.V.

specified by the respective se- specified by the respective se- specified by the respective security system
curity system
curity system
IP 52

IP 54

IP 52

-10C . . . +55C

-25C . . . +70C

-10C . . . +55C

red, RAL 3001

red, RAL 3001

blue, RAL 5005

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points | 245

FMC-120-DKM Single Action Call Points

FMC-120-DKM-H-B

FMC-120-DKM-G-Y

FMC-120-EST-G-B

outdoor

indoor

indoor

Mounting

surface-mounted/flushmounted

surface-mounted/flushmounted

surface-mounted/flushmounted

Operating voltage

16.2 V DC . . . 30 V DC

16.2 V DC . . . 30 V DC

16.2 V DC . . . 30 V DC

Range of use

Current consumption

specified by the respective se- specified by the respective se- specified by the respective security system
curity system
curity system
IP 54

IP 52

IP 52

Permissible operating temperature

-25C . . . +70C

-10C . . . +55C

-10C . . . +55C

Color

blue, RAL 5005

yellow, RAL 1003

blue, RAL 5005

Protection category

www.boschsecurity.com

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

246 | Manual Call Points | Accessories - Manual Call Points LSN and Conventional

Punched, Self-adhesive
Foil Sets (Blank), for Operating Panel and Labeling
Field

FMXFSOLSN Punched,
Self-adhesive Foil Sets
(Blank)

7
For the labeling field of manual call points of the Series
FMC210.
10 punched foil sets, appropriate for DM/DKM/SM/SKM, for
individual printing with a customary laser printer

1 unit = 10 sheets

The required print file is available on the WinPara diskette.

Appropriate for printing at standard laser printers. The


required print file is available on the WinPara disk.

Ordering Information

Ordering Information

Punched, Self-adhesive Foil Sets (Blank),


for Operating Panel and Labeling Field
10 units, for DM/DKM/SM/SKM, for individual
printing

Bosch Security Systems B.V.

DKM120-LABEL

FMXFSOLSN Punched, Self-adhesive Foil


Sets (Blank)
For the labeling field of manual call points of
the Series FMC210.
1 unit = 10 sheets

FMX-FSO-LSN

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Accessories - Manual Call Points LSN and Conventional | 247

FMXFSOGLT Punched,
Self-adhesive Foil Sets
(Blank)

FMCFSTDE Printed
Labeling Foils for the
Upper Label Field

7
For the labeling field of conventional manual call points of
the Series FMC120.
1 unit = 10 sheets
Appropriate for printing at standard laser printers. The
required print file is available on the WinPara disk.

Ordering Information
FMXFSOGLT Punched, Self-adhesive Foil
Sets (Blank)
For the labeling field of conventional manual
call points of the Series FMC120,
1 unit = 10 sheets

www.boschsecurity.com

FMX-FSO-GLT

For yellow and blue manual call points of Series FMC120


and FMC210.
1 unit = 5 sheets
All labeling foils meet the requirements of the EN 120943
(use in gas extinguishing system).

Ordering Information
FMCFSTDE Printed Labeling Foils for the
Upper Label Field
For yellow and blue manual call points of Series
FMC120 and FMC210, 1 unit = 5 sheets

FMC-FST-DE

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

248 | Manual Call Points | Accessories - Manual Call Points LSN and Conventional

FMCSPGLDEIL Spare
Glasses
For manual call points of Series DM, DKM, SKM, FMC120
and FMC210.
1 unit = 5 spare glasses

Ordering Information
FMCSPGLDEIL Spare Glasses
For manual call points of Series DM, DKM, SKM,
FMC120 and FMC210.
1 unit = 5 spare glasses

FMC-SPGL-DEIL

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Conventional Manual Call Points for Ex Areas | 249

Conventional Manual Call


Points for Ex Areas

Functions
In the event of an alarm, the glass pane (2) is broken first,
then the pushbutton (3) is pressed hard. Thus the switch
triggers the alarm.
A locking mechanism holds the pressed manual call point.
The pushbutton can be reset with the reset lever.
This does not reset the alarm on the fire panel.

Certifications and Approvals


Region

Certification

Europe

CE

DM 1103

BASEEFA

Ex 98E2304 DM 1103 B-Ex

VdS

G 297060 DKM 2014/2-ex/-GLU

Germany

G 295036 DM 1103 B-Ex

The Conventional Manual Call Points for Ex Areas are used


to manually activate the alarm in zones 1 and 2 at risk of
explosion.
The K type call points are encapsulated, intrinsically safe
call points and do not require any safety barriers.

PTB

97 ATEX 3197 DKM 2014/2 / DKM


2014/2-GLU

Hungary

TMT

TMT-50-05/2004 DM 200, DM 210, DKM


120, DM 1103B-Ex

Russia

GOST

POCC DE.C313.B06297

Installation/Configuration Notes

The DM 1103 BEx Manual Call Points for ex zones must be


connected via a Safety Barrier SB 3 incl. Input/Output
Module DCA1192 (see system overview).

System Overview

2
EOL22(Ex)

DFA1101A-Ex

FLM-420/4-CON
DO1101A-Ex

DCA1192

SB3

DCA1192

SB3

For DM 1103 BEx:


Pos.

Description

Non-ex area

Ex area zone 1 or 2

www.boschsecurity.com

DO1101A-Ex

DM 1103 B-Ex

DM 1103 B-Ex

Manual call points must be illuminated sufficiently with


daylight or another light source (including emergency
lighting, if present).
An installation height of 1400 mm 200 mm, measured
from the middle of the manual call point to the floor,
must be maintained.
Manual call points must be installed along escape and
rescue routes (e.g. exits, passageways, stairwells).
Further standards, guidelines and planning
recommendations regarding the installation location
etc., should also be taken into consideration (see Fire
Detection manual).
Regulations of local fire departments must be observed.

Installation/configuration notes in accordance with VdS/


VDE
The distance between manual call points should not
exceed 100 m according to DIN 14675 or 80 m
according to VdS.
In high risk areas, manual call points should be installed
at a distance of max. 40 m (VDE 0833 Part 2,
Point 7.2.6).
According to VdS, up to 10 manual call points can be
connected to a primary line.
DKM 2014/2ex Manual Call Point Type K
For connection to the LSN, an NBK 100 LSN Fire
Interface is required.
Can be connected directly to the following conventional
control panels:
- BZ 1012
- BZ 1060
- UEZ 1000 GLT.
With an NBK 100 LSN Fire Interface, can be connected
to the following control panels:
- BZ 500 LSN
- UEZ 1000 LSN

Bosch Security Systems B.V.

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

250 | Manual Call Points | Conventional Manual Call Points for Ex Areas

UEZ 2000 LSN


UGM 2020 LSN

DKM 2014/2exUGM Manual Call Point Type K, for


Connection to UGM Conventional
Can be connected directly to the UGMGLT Universal
Danger Detection System
DM 1103 B-Ex manual call point for ex area
For connection to the LSN, an NBK 100 LSN interface is
required.
For use in explosive areas of zones 1 and 2, a safety
barrier and an input/output module are required, which
must be mounted in front of the ex area.
Cables can be inserted surface-mounted or flushmounted

Parts Included

Type

Qty. Components

DKM 2014/2ex

Manual Call Point Type K, for ex areas, for


surface mounting

DKM 2014/2exUGM

Manual Call Point Type K, for Connection to


UGM Conventional, for ex areas, for surface
mounting

DM 1103 B-Ex

1
1
2

DM 1103 B-Ex manual call point, color red


Key for DM1103B-Ex manual call point
PG11 cable screws

Dimensions (W x H x D)

134.4 x 134.4 x 43.5 mm

Weight

Approx. 200 g

Protection class as per EN 60529

IP 54

Permissible operating temperature -25 C to +60 C


Permissible storage temperature

-30 C to +75 C

Permissible relative humidity

100% at T34 C

Ex classification

EEx ib IIC T4

Ordering Information
DKM 2014/2ex Manual Call Point Type K
for Ex area

DKM 2014/2-ex

Key for Fire Detector Type K

FMX-7743.0.0500

DKM 2014/2exUGM Manual Call Point


Type K, for Connection to UGM
Conventional
for ex area, exclusively for use in conjunction
with the Universal Danger Detection System
UGMGLT

DKM 2014/2-exUGM

Key for Fire Detector Type K

FMX-7743.0.0500

DM 1103 BEx Manual Call Point


for zone 1 and 2 areas at risk of explosion

DM1103B-Ex

SB3 Safety Barrier incl. DCA1192 Input/


Output Module

SB3

Accessories

Technical Specifications
DKM 2014/2ex Manual Call Point Type K
DKM 2014/2exUGM Manual Call Point Type K, for Connection to UGM
Conventional
Operating voltage

24 V DC

Switch contact

Type 366 (encapsulated), II 2 G EEx


d II C

Maximum contact load

5 A / 250 V AC
0,25 A / 250 V DC

Cable entry

FMCSPGLDEIL Spare Glasses


For manual call points of Series DM, DKM, SKM,
FMC120 and FMC210.
1 unit = 5 spare glasses

FMC-SPGL-DEIL

1x M16 x 1.5 tightening diameter 48 mm, EEx e II


Blind plug: 1x M16 x1.5 EEx e II

Housing material

Polyester, glass fiber reinforced

Colors

Red, RAL 3001

Dimensions (W x H x D)

136 x 138 x 88 mm

Weight

Approx. 1800 g

Protection class as per EN 60529

IP 66

Permissible operating temperature -25 C to +40 C


Ex classification

Eex emd IIC T6

Test certificate / PTB No.

97-37001

ATEX approval no.

PTB 97 ATEX 3197

DM 1103 BEx Manual Call Point


Operating voltage

16V DC to 28V DC

Cable duct

PG11 screws (2x)

Connection terminals

0.2 mm to 1.5 mm

Housing material

Plastic, PC

Color

Red, RAL 3000

Bosch Security Systems B.V.

www.boschsecurity.com

Fire_T2365506827_20090818T1526_EMEA_en-US_print_RC8.08f_cza5ot_DatabookPDF

Manual Call Points | Accessories - Manual Call Points for Ex Areas | 251

SB3 Safety Barrier incl.


DCA1192 Input/Output
Module

Technical Specifications
SB3 Safety Barrier, with Housing
Max. voltage

28 V DC

Max. permissible current

100 mA

Max. output

0.7 W

Wire gauge

0.2 mm2. . . 2.5 mm2

Cable bushings

PG16 (6x)

Dimensions (W x H x D)

135 x 135 x 65 mm

Housing material

Plastic, PC

Housing color

White, RAL 9010

Weight

Approx. 450 g

Protection class as per EN 60529

IP 56

Permissible operating temperature -25 C . . . +70 C

Functions
The SB3 Safety Barrier limits the electrical energy between
non-inherently safe and inherently safe circuits and thus
prevents the ignition of gas mixtures by electrical sparks.
The Safety Barrier must always be installed outside the
explosive area.
The DCA1192 Input/Output Module is the galvanical
isolation between the fire panel and SB3 Safety Barrier.

Permissible storage temperature

-30 C . . . +75 C

Ignition protection according to


EN 50014/20

Inherent safety EEx ia IIC / IIB

DCA1192 Input/Output Module, with Housing


External supply

Operating voltage

18 V DC . . . 32 V DC

Current consumption

Max. 5 mA

Line resistance

50 . . . 250

Line termination

EOL22(Ex)

Line termination

Certifications and Approvals


Region

Certification

Europe

CE

Germany

DC 1192

Operating voltage

18 V DC . . . 22 V DC

Standby current

45 mA

Operating current

150 mA

Line resistance

50 . . . 250

Line termination

EOL22(Ex)

SB 3

Wire gauge

0.2 mm2. . . 2.5 mm2

CPD

0786-CPD-20512 DC 1192

Cable bushings

PG16 (6x)

VdS

G 298021 DC 1192

Housing material

Plastic, PC

PTB

01 ATEX 2088 SB 3

Housing color

White, RAL 9010

Dimensions (W x H x D)

135 x 135 x 65 mm

Weight

Approx. 425 g

Protection class as per EN 60529

IP 56

Parts Included
Qty.

Components

SB3 Safety Barrier

Installation set for SB3

DCA1192 Input/Output Module

Terminal carrier for DCA1192

EOL22(Ex) line termination, included with the DCA1192

Housing with cover

www.boschsecurity.com

Permissible operating temperature -25 C . . . +70 C


Permissible storage temperature

-30 C . . . +75 C

Permissible relative humidity

100% at T34 C

Ordering Information
SB3 Safety Barrier incl. DCA1192 Input/
Output Module

SB3

Bosch Security Systems B.V.