(1)
Where q is heat transfer rate (w)
K is thermal conductivity of the wall (w/m.K)
A is perpendicular area to the direction of heat flow (m2)
x is wall thickness (m)
T2 is temperature on the cold surface of the wall (K)
T1 is temperature on the hot surface of the wall (K)
In heat transfer we may consider thermal resistance to be:
(2)
where (T1-T2) is the difference of temperatures and q is the heat transfer rate.
From eq. (1), conduction thermal resistance may be determined:
(3)
Convection: the heat transfer mode between a surface and a fluid in motion which are at
different temperatue. Convection heat transfer may be classified as either forced or natural
convection.
The convection heat transfer rate a surface and a fluid is given by Newton's law of colling,
which is expressed as:
N.T.Linh
Quarter 3, 2015
Page 1
ECH 155B
(4)
where q is convection heat transfer rate (w)
h is convection heat transfer coefficient (w/m2.K)
A is heat transfer area (m2)
Ts is surface temperature (K)
T Fluid temperature (K)
Heat transfer in heat exchangers
A heat exchanger is a device developed to allow heat transfer to happen between two fluids at
different temperatures separated by a solid wall. They have multiple applications in chemical
engineering. The most simple is built with two concentric tubes, where fluids may either move
in the same or in opposite direction. In parallet flow, hot and cold fluids may enter and leave at
the same end while flowing in the same direction. In countercurrent flow fluids may enter and
leave at opposite ends, flowing in opposite directions.
Parallet flow
Shell and Tube heat exchanger
The other common configuration is the internal and external tube exchanger constituted by a group of
tubes inside and external tube. These exchangers usually feature baffles to increase heat transfer.
Global heat transfer coefficient
To represent the global phenomenon of heat transfer among fluids in a exchanger, we may refer to the
thermal resistances which appear in each medium.
Heat flow on its way between hot and cold fluid must overcome the resistances created by the hot
fluid limit layer, the separation wall and the cold fluid limit layer.
These three resistances arranged in series constitute the total resistance (Rt), which is the sum of each
individual resistance.
N.T.Linh
Quarter 3, 2015
Page 2
ECH 155B
Tube wall
Temperature
distribution
Cold fluid
Hot fluid
1/hhAh
T,h
Ts,h
x/K.A
Ts,c
1/hcAc
T,c
N.T.Linh
Quarter 3, 2015
Page 3
ECH 155B
(5)
The global heat transfer coefficient U is defined as a factor that, for a given geometric and
hydrodynamic configuration, provides the total amount of heat transferred when multiplying it by the
exchange area and by the total temperature differences.
(6)
Where by comparision with the eq. (5), we obtain:
(7)
For a Shell and Tube exchanger of length L, in which the hot fluid flows through th internal
tube and cold fluid flows through the space between the internal and external tubes. The
exchange surfaces will be Ah = .Dint.L and Ac = .Dext.L, with Dint and Dext being the internal
and external diameters of the exchanger. Due to the fact that the wall has a cylindrical shape,
the conduction resistance will have to be expressed:
(8)
The most influential terms concerning the toatal thermal resistance value are the convection
terms. Due to the fact that diameters are specified, it will be key to determine the convection
heat transfer coefficient (h) in order to predict heat exchange.
Convection heat transfer coefficient (h)
The heat exchanger operates with two fluids moving at known velocities. therefore,
convection will be forced.
To achieve the calculation of the h coefficient, we will need to base our calculations upon
dimensional analysis of Navier- Stokes equations of fluid mechanics. These results indicate
that the dimensionless temperature difference is a function of Reynolds Number (Re), Prandtl
Number(Pr), and of the dimensionless geometry. If Nusselt Number (Nu) is defined as the
dimensionless temperature gradient on the surface we may be able to designate Nu as a
function of Re, Pr, and the dimensionless geometry.
Nu = f(Re, Pr, dimensionless geometry)
(9)
Where
being = fluid density (kg/m3)
u = average velocity of the fluid at the tran sversal section of the tube (m/s)
D = internal diameter of the fluid (kg/m.s)
N.T.Linh
Quarter 3, 2015
Page 4
ECH 155B
ST 16 (oC)
Test 1
Test 2
Test 3
Test 4
45
50
55
60
ST1 ( C)
ST 2 (oC)
ST 3 (oC)
ST 4 (oC)
ST 5 (oC)
ST 6 (oC)
ST 7 (oC)
SC 1 (l/min)
SC 2 (l/min)
N.T.Linh
Quarter 3, 2015
Page 5
ECH 155B
Data analysis
Considering the measurement above, you may calculate the following thermodynamic variables:
- Heat transfer by the hot water (qh)
- Heat absorbed by tha cold water (qc)
- Heat losses (ql)
- Logarithmic average temperature difference between hot and cold (Tlm).
- Global heat transfer coefficient (U)
- Hot and cold water viscosity in the exchanger (h, c)
- Reynolds number for hot and cold water (Reh, Rec).
- Calculate convection heat transfer cofficient (h): h=Nu.Kf/D (Nu=Nusselt number)
Conclusions and comments
Analyze flow influence on heat transfer.
N.T.Linh
Quarter 3, 2015
Page 6