Anda di halaman 1dari 33

Filters

Quality and Service


Worldwide

PRESSURE FILTERS
SF SERIES

TECHNICAL DATA
STAUFF high pressure filters are designed for in-line hydraulic applications,
with a maximum operating pressure of
6000 psi (420 bar). Used together with
STAUFF filter elements, a high efficiency
of contaminant removal is assured. The
high dirt holding capacity of the
elements ensures long service life and, as
a result, reduced maintenance.

Contamination Indicator
Filter Head

Valve

Filter Bowl

TECHNICAL SPECIFICATIONS/OPTIONS
Construction

In-line assembly, with threaded


mounting holes on top of head

Filter head

Spheroidal graphite cast iron

Filter bowl

Cold drawn steel

Seals

O-Rings NBR (Buna-N),


FPM (Viton), EPDM (Ethylenepropylene), Support ring PTFE

Port connection

NPT, SAE O-Ring thread,


SAE Code 61 & 62 flange

Operating press. max.

6000 psi (420 bar)

Proof pressure

9000 psi (630 bar)

Burst pressure

>18000 psi (1260 bar)

Temperature range

-10C up to +100C
14F to 212F

Bypass valve

Allows unfiltered oil to bypass


the contaminated element
once the opening pressure of
87 psi +7 psi (6 bar + 0.5 bar)
has been reached

Reverse flow
valve

Allows reverse flow through the


filter head without back flushing
the element

Non-return
valve

Prevents draining of the delivery


line during element change
Note: System Pressure must be
relieved before element change out

Multi-function
valve

Forward bypass, reverse flow


capability, and non return valve
(opening pressure 87 psi +
- 7 psi
(6+
- 0.5 bar) p all in one valve

Contamination
indicators

Visual, 72 psi+
- 7 psi (5+
- 0.5 bar)
p actuating pressure
Electrical, 72 psi+
- 7 psi (5+
- 0.5 bar)
p Visual/electric, 72 psi+
- 7 psi (5+
- 0.5
bar) p (12 V, 24 V, 110 V,
220 V versions)

Filter elements

Filter material specification,


B, D, E, G, N, S. low collapse;
rating 430 psi (30 bar) p
Filter material specification,
A, C, F, H, T, W. high collapse;
rating 3000 psi (210 bar) p

Media

Mineral oils; other fluids on request

3/00

FILTRATION

Filter Element

86

PRESSURE FILTERS
SF SERIES

VALVE OPTIONS
The optional valves are fitted as an insert in the filter head and incorporate the spigot on which the element seals.
The valve is selected to suit the filter application.
HV - O

Non-bypass standard insert with no valve


function. High collapse elements 3000 psi (210
bar p) are normally used with this valve.

HV - B

Bypass valve which allows oil to bypass the


element when the differential pressure across the
element reaches 87 psi +7 psi (6+0.5 bar). (Other
pressure settings available on request). The
opening pressure should be higher than the p
setting of an optional contamination indicator.
Low collapse 430 psi (30 bar p) elements are
normally used with this valve.

HV - R

HV - N

Non-return valve This valve prevents the oil


in the delivery line from draining out while
the filter is being serviced. High collapse
elements 3000 psi (210 bar p) are normally
used with this valve.

HV - M

Multi-function valve This valve combines


the by-pass, the reverse flow, and the nonreturn functions in one unit. The by-pass
opening pressure is 87 psi +7psi (6+0.5 bar)
p with other opening pressures available on
request. The opening pressure should be
higher than the p setting of an optional
contamination indicator.

Reverse flow valve is used in systems where there


is flow in reverse through the filter. It allows
reverse flow without back-flushing the element
but does not filter in the reverse direction. High
collapse elements 3000 psi (210 bar p) are
normally used with this valve.

ORDERING INFORMATION

PRODUCT TYPE

O
B
R
N
M

3/00

045/070

CODE VALVE TYPE

HVValve

HV-O

HV-B

FILTER GROUP
014/030

Non-bypass standard
insert without any valve
Bypass Valve
Reverse Flow Valve
Non Return Valve
Multi-Function Valve

HV-R

FILTRATION

HV

045/070
090/160

HV-N

HV-M

A
A

A
A

A
A

A
A

A
A

Flow characteristics of the valves see page 91.

87

PRESSURE FILTERS
SF SERIES

CONTAMINATION INDICATORS
STAUFF pressure filters have a range of contamination indicators available as an option. If no indicator is specified, the port is sealed
by a plug (HI - O). The contamination indicators are actuated by the differential pressure (p) across the element and the special
piston design minimizes the effects of peak pressures in the system. An optional thermostatic lockout (thermo-stop) is available to
prevent false indication under cold start conditions. Fluid temperature must be at least 68F (20C) for the indicator to function.

TECHNICAL SPECIFICATION
Body

Stainless steel

Seals

NBR, FPM, EPDM


18.5 x 23.9 x 2mm
15.5 x 1.5mm

Visual contamination indicators are available in the


following configurations:
Manual reset

The indicator continues to display contamination even through the p may


have fallen. Pressing the plastic cover
down will reset the indicator.

Automatic reset

The contamination signal will disappear


when the p drops below the setting for
the indicator.

/2 BSP

Thread

Differential
pressure setting
Electrical

72 psi+
- 7 psi (5+
- 0.5 bar)
(other settings on request)

Note: Electrical and Visual-Electrical contamination


indicators are only available with automatic reset.

Standard DIN appliance plug


Screwed cable gland PG 11
Protection rating (DIN 40050) IP65
Both NO and NC contacts are
available in the switch
Rated capacity: see chart below

HI -

T - 220

PRODUCT TYPE
HI

SEALING MATERIAL

Contamination Indicator

B
V
E

CODE EXECUTION
O
A
V
E
P

PLUG
VISUAL, AUTOMATIC RESET
VISUAL, MANUAL RESET
ELECTRICAL
VISUAL ELECTRICAL

HI-O

HI-A HI-V

NBR - Buna -N
FPM - Viton
EPDM

VOLTAGE
12

THERMOSTOP
T

HI-E

(ONLY FOR CODE P)

12V

24
110
220

WITHOUT THERMOSTOP
WITH THERMOSTOP

24V
110V
220V

HI-P...
SL
SL

1 (+)

MP

Rated Capacity HI-E and HI-P

Alternating Current 250V AC 5 Amps

80
3.14"

27
1.06"
G 1/2

25.4
1.00"

25.4
1.00"
G 1/2

G 1/2

88

Voltage
V

Resistive
Load
Amps

Inductive
Load
Amps

12

15.00

15.00

24

8.00

7.00

110

0.50

0.20

220

0.25

0.10

Note: High voltage peaks occur


when inductive loads are switched
off. Protective circuitry should be
employed to reduce contact burnout.

3/00

G 1/2

25.4
1.00"

25.4

10.5

75
2.95"

Direct Current: see table below

1.00" .41"

FILTRATION

ORDERING INFORMATION

PRESSURE FILTERS
SF SERIES

DIMENSIONS
b1

h2

h1

h3

h4

d2

SW

FILTRATION

d1

Code 62
Flange connection

Threaded connection

Mounting Hole Dimensions


CODE 61 FLANGE CONNECTION

b2
7

G3

G3

/8

22.2

17/8

46.6

SF045/70

13/16

30.2

2 5/16

58.7 7/16-14

SF090/100

113/32 35.6

2 3/4

69.8

b3

SF014/30

G3

b3

b3

/8-16

b2

b2

/2-13

Note: Mounting holes match Code 62 connection for that size

DIMENSIONS PRESSURE FILTERS


FILTER
SIZE
SF014
SF030
SF045
SF070
SF090

3/00

SF160

STANDARD
THREADED
CONNECTION

SAE
b1
FLANGE
NPT SAE O-RING CODE 62 inch mm
3/ "
4

1 1/4"

1 1/2"

1 1/16"- 12

1 5/8"- 12

1 7/8"- 12

3/ "
4

1 1/4"

1 1/2"

4.09 104

5.51 140

7.01 178

b2

b3

d1

d2

inch mm

inch mm

inch mm

inch mm

0.94 23.8

1.24 31.6

1.44 36.7

2.0

2.63

3.13

50.8

66.7

79.4

2.68

3.74

5.12

68

95

3.27

4.57

130 6.26

h1

h2

inch

mm

inch

7.4

188

3.07

h3

mm

10.0

254

5.67 144

9.4

240

4.06 103

11.7

298

6.34 161

mm

1.89

48

12.7

323

5.83 148

19.5

495 12.56 319

1.95 49.5

116

159

89

inch

inch

g3
mm

78

83

CONNECTION G

h4

2.83

72

inches
3 " 8

16
UNC

0.49 12.5

1 " 2

13

UNC
5
8" -

11

UNC

SW
inch

mm

1.06

27

WEIGHT
INCLUDING
ELEMENT
lbs
kgs
11

1.06

1.42

13

26

12

27
28

13

65

29.5

81

37

36

PRESSURE FILTERS
SF SERIES

ORDERING CODE FILTER HOUSINGS


SF 014 G10 V T B / B P T 220
Filter type

VOLTAGE (ONLY FOR CODE P)


12
12 V
24
24 V
110
110 V
220
220 V

SF
GROUP

SIZE
014
030
045
070
090
160

NOMINAL FLOW*
L/MIN
60
110
160
240
330
660

GPM
14
30
45
70
90
160

0
T

CONTAMINATION INDICATOR
O without contamination indic.
A visual, with autom. reset
V visual, with manual reset
E electrical
P visual/electrical

*Note: Exact flow will depend on filter


element selected. Consult Technical
Data on pages 91, 92 & 93.

FOR COMPLETE FILTERS:


identification filter material
+ micron rating code

O
B
R
N
M

SEAL MATERIAL
NBR - Buna-N
FPM - Viton
EPDM

PORT STYLE

other seal materials on request

CODE
N
U

MOUNTING STYLE
T
In Line (straight)

VALVE
without valve
Bypass valve
Reverse flow valve
Non return valve
Multi-function valve

GROUP

CONNECTION STYLE

014

030

045

070

090

160

3
NPT
4
114
112
SAE-O-Ring thread 1116 12 UNF 158 12 UNF 178 12 UNF
3
SAE-flange
4
112
114

(6000 psi)

SAE-flange

BSP

(3000 psi)

114

112

G 34

G 114

G 112

other port connections on request

ORDERING CODE FILTER ELEMENTS

SE 014 G 10 V
SERIES

SE

B
V
E

other seal materials on request

GROUP
according to filter housing

MICRON RATING

FILTER MATERIAL
Code
A
C
N, D
G, E
H, F
B, S
T, W

SEAL MATERIAL
NBR - Buna-N
FPM - Viton
EPDM

Material
Stainless fiber
Polyester fiber
Paper
Inorganic glass fiber
Inorganic glass fiber
Stainless mesh
Stainless mesh

p max
3000 psi (210 bar)
3000 psi (210 bar)
430 psi (30 bar)
430 psi (30 bar)
3000 psi (210 bar)
430 psi (30 bar)
3000 psi (210 bar)

03
05
10
20
25
40
60
100

MICRON RATINGS
AVAILABLE

03, 05,
10, 20
25, 40,
60, 100

3
5
10
20
25
40
60
100

m
m
m
m
m
m
m
m

other micron ratings on request


3/00

FILTRATION

(see ordering code filter elements below)

B
V
E

THERMOSTOP
without Thermostop
with Thermostop

Bold type identifies preferred material

90

PRESSURE DROP/ FLOW CURVES

FLOW CHARACTERISTICS OF PRESSURE FILTERS


The following flow characteristics are valid for mineral oils with a specific gravity of 0.85 and the kinematic
viscosity of 141 SSU (30 cSt). The characteristics have been determined in accordance to ISO 3968.

Bypass Valve Flow Characteristics

Housing Characteristics SF
Filter Size

(incl. housing resistance, without element)

Filter Housing Size SF 014/030

Psi
23.5

Bar
1.6

20.5

1.4

17.5

1.2

14.5

1.0

12.0

0.8

9.0

0.6

6.0

0.4

3.0

0.2

0.0

0.0

Bar
16.0

203.0

14.0

174.0

12.0

145.0

10.0

116.0

8.0

87.0

6.0

58.0

4.0

29.0

2.0

0.00

0.0

Bypass Valve
F

E
B
D
A, C

0%
0%

5.5
20%

10.5
40%

16.0
60%

21.0
80%

26.0
100%

31.5 GPM
120%

Q in gpm as a percentage of the filter size

0
0

5.5
20

10.5
40

16.0
60
Q

21.0
80

26.0
100

Psi
12.0

Filter Housing Size SF 045/070


Bar Filtergehuse Baugre SF 045/070
0.8

10.5

0.7

10.0

0.6

7.5

0.5

6.0

0.4

4.5

0.3

3.0

0.2

1.5

0.1

0.0

0.0

Filter
Filter
Filter
Filter
Filter
Filter

31.5 GPM
120 LPM

Size SF
Size SF
Size SF
Size SF
Size SF
Size SF

014:
030:
045:
070:
090:
160:

Characteristics of the
multi-function valve
are approximately 5%
higher than those of
the bypass valve

A
B
C
D
E
F

Reverse Flow Valve


Psi Bar
58.0 4.0

Flow Direction A
>B

43.5 3.0
A

p 29.0 2.0
B
14.5 1.0

0
0

11.0
40

21.0
80

32.0
120

42.0
160

52.0
200

0.0 0.0

63.0 GPM
240 LPM

0%

20%

40%

60%

80%

100% 120%

Q in gpm as a percentage of the filter size

Filter Housing Size SF 090/160


Psi Bar Filtergehuse Baugre SF 090/160
30.0 2.0

Psi
58.0

Bar
4.0

26.5 1.8

43.5

3.0

29.0

2.0

14.5

1.0

0.0

0.0

Flow Direction B
>A
A

23.5 1.6

20.5 1.4
17.5 1.2

14.5 1.0
12.0 0.8
9.0

0.6

6.0

0.4

3.0

0.2

0.0

0.0

0%

20%

40%

60%

80%

100% 120%

Q in gpm as a percentage of the filter size

26.0
100

52.0
200

78.0
300
Q

104.0
400

130.0
500

A: Filter Size SF 030 / SF 070 / SF 160


B: Filter Size SF 014 / SF 045 / SF 090

156.0 GPM
600 LPM

Characteristics of the multi-function valve are


approximately 15% higher than those of the
bypass valve.

3/00

0
0

91

FILTRATION

Psi
235.0

PRESSURE DROP/ FLOW CURVES

ELEMENT FLOW CHARACTERISTICS


Psi Bar
14.5 1.0

SE 014 A
03 m

12.0 0.8
9.0

0.6

6.0

0.4

3.0

0.2

05 m

Psi
14.5

Bar
1.0

12.0

0.8

9.0

0.6

6.0

0.4

3.0

0.2

SE 030 A

Psi Bar
14.5 1.0
03 m
05 m

SE 045 A

12.0 0.8
03 m
9.0

0.6

6.0

0.4

3.0

0.2

0.0

0.0

05 m

10 m
20 m

10 m

10 m

20 m
0.0

0.0

0.0
0

3.0

5.5

8.0

10.5

13.0

16.0

GPM

10

20

30

40

50

60

LPM

0.0
0
0

5.5
20

10.5
40

SE 014 C

Psi
58.0

Bar
4.0

51.0

3.5

43.5

3.0

36.5

2.5

29.0

2.0

22.0

1.5

10 m

22.0 1.5

14.5

1.0

20 m

14.5 1.0

7.5

0.5

0.0

0.0

3.5
3.0

36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

Bar
4.0

51.0

3.5

43.5

3.0

36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

03 m
05 m

10 m
20 m

3.0
10

5.5
20

8.0
30
Q

10.5
40

SE 014 H

13.0
50

03 m

10 m
20 m

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

0.0

0.0

Psi Bar
58.0 4.0

03 m
05 m

16.0 GPM
60 LPM

10 m

10.5
40

16.0
60
Q

21.0
80

26.0
100

SE 030 G
03 m

43.5

3.0

05 m

36.5

2.5

1.5
1.0

7.5

0.5

0.0

0.0

03 m
05 m

36.5 2.5

22.0 1.5
10 m

7.5 0.5

31.5 GPM
120 LPM

3.5

14.5

43.5 3.0

20 m

0.0 0.0
5.5
20

Bar
4.0

2.0

SE 045 C

14.5 1.0
20 m

51.0

22.0

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPM


40
60
80 100 120 140 160 LPM
Q

29.0 2.0

Psi
58.0

29.0

5.5
20

51.0 3.5

0
0

0
0

Psi Bar
58.0 4.0

5.5
20

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPM


40
60
80 100 120 140 160 LPM
Q

SE 045 G

51.0 3.5

03 m

43.5 3.0
36.5 2.5

10 m
20 m

0
0

16.0 GPM
60 LPM

05 m

0.5

16.0 GPM
60 LPM

SE 014 G

0
0

Psi
58.0

SE 030 C

36.5 2.5

7.5

20 m
0
0

31.5 GPM
120 LPM

51.0 3.5

29.0 2.0

Psi Bar
58.0 4.0

43.5

26.0
100

43.5 3.0
05 m

0
0

51.0

Psi Bar
58.0 4.0
03 m

21.0
80

5.5
20

10.5
40

16.0
60

21.0
80

26.0
100

31.5 GPM
120 LPM

29.0 2.0

14.5 1.0

10 m

7.5 0.5

20 m

0.0 0.0
0
0

SE 030 H

03 m

05 m

22.0 1.5

Psi
58.0

Bar
4.0

51.0

3.5

43.5

3.0

36.5

2.5

36.5 2.5

29.0

2.0

29.0 2.0

22.0

1.5

10 m

22.0 1.5

14.5

1.0

20 m

14.5 1.0

7.5

0.5

0.0

0.0

Psi Bar
58.0 4.0

5.5
20

SE 045 H
03 m

51.0 3.5
05 m

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPM


40
60
80 100 120 140 160 LPM
Q

43.5 3.0
05 m

10 m
20 m

7.5 0.5
0.0 0.0
0
0

5.5
20

10.5
40

16.5
60
Q

21.0
80

26.0
100

31.5 GPM
120 LPM

0
0

5.5
20

10.5 16.0 21.0 26.0 31.5 36.5 42.0 GPM


40
60
80 100 120 140 160 LPM
Q

3/00

FILTRATION

16.0
60
Q

92

PRESSURE DROP/ FLOW CURVES

ELEMENT FLOW CHARACTERISTICS


SE 070 A

Psi Bar
14.5 1.0
12.0 0.8
9.0

0.6

6.0

0.4

3.0

0.2

Psi
14.5

Bar
1.0

03 m

12.0

0.8

05 m

9.0

0.6

6.0

0.4

3.0

0.2

SE 090 A

Psi

Psi Bar
58.0 4.0

10.5

21.0

31.5

42.0

52.0

62.5

GPM

40

80

120
Q

160

200

240

LPM

10 m

Bar
4.0

51.0

3.5

43.5 3.0

43.5

3.0

36.5 2.5

36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

03 m
05 m

29.0 2.0
22.0 1.5

10 m
20 m

14.5 1.0
7.5 0.5
0.0 0.0
42.0
160

31.5
120
Q

52.0
200

62.5
240

GPM
LPM

51.0 3.5
03 m

43.5 3.0
36.5 2.5

05 m

29.0 2.0
22.0 1.5

10 m

14.5 1.0

20 m

7.5 0.5
0.0 0.0
0

10.5
40

21.0

31.5
120
Q

80

42.0
160

52.0
200

Psi
58.0

Bar
4.0

51.0

3.5

43.5

3.0

36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

240

LPM

Bar
4.0

3.5

51.0

3.5

3.0

43.5

3.0

36.5

2.5

29.0

2.0

22.0

1.5

4.0

51.0
43.5
36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

SE 070 H
03 m

05 m

10 m
20 m

10.5

21.0

31.5

42.0

52.0

62.5

GPM

40

80

120

160

200

240

LPM

Bar
0.10

1.2

0.08

.9

0.06

.6

0.04

10 m
20 m

29.0

57.5

86.0

GPM

110

220

330

LPM

14.5

1.0

7.5

0.5

0.0

0.0

0.02

.0

0.00

0%
3/00

57.5
220

Psi

Bar
4.0

51.0

3.5

43.5

3.0

36.5

2.5

03 m

29.0

2.0

22.0

1.5

05 m
10 m

14.5

1.0

7.5

0.5

0.0

0.0

SE 160 C

20 m
55.0
210

86.0
330

SE 160 G

43.5

3.0

36.5

2.5

29.0

2.0

03 m

22.0

1.5

05 m

10 m

14.5

1.0

20 m

7.5

0.5

0.0

0.0

GPM
LPM

10 m
20 m
0
0

55.0
210

20 m

57.5
220

86.0
330

Psi

Bar

58.0

4.0

51.0

3.5

43.5

3.0

36.5

2.5

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

05 m
10 m
20 m

0
0

GPM
LPM

55.0
210

Pressure Filter Elements


with Filter Material D
SE ... D

7.5 0.5

10 m

4.5 0.3
3.0 0.2
20 m

1.5 0.1
0.0 0.0

60%

80%

0%

100% 120%

20%

40%

60%

80%

100% 120%

Q in gpm as a percentage of the nominal flow

93

109.5
420
Q

Psi Bar

40%

GPM
LPM

03 m

6.0 0.4

20%

164.0
630

SE 160 H

Q in gpm as a percentage of the nominal flow

109.5
420
Q

10 m

60 m

GPM
LPM

3.5

05 m

40 m

164.0
630

Bar
4.0

03 m

25 m

109.5
420

51.0

SE 090 H

29.0
110

GPM
LPM

Psi
58.0

05 m

0
0

164.0
630

03 m

29.0
110

109.5
420

58.0

0
0

SE 090 G

SE ... B

.3

55.0
210
Q

05 m

Pressure Filter Elements


with Filter Material B
Psi

0
0

03 m

1.5

GPM
LPM

Psi

Bar

86.0
330

SE 090 C

0
0

62.5 GPM

58.0

Psi
58.0

57.5
220

SE 070 G

29.0
110

164.0
630

GPM
LPM

FILTRATION

Psi Bar
58.0 4.0

20 m

0.0 0.0
0
0

Psi
58.0

21.0
80

10 m

3.0 0.2

0.0

51.0 3.5

10.5
40

05 m

6.0 0.4

SE 070 C

0
0

9.0 0.6

20 m
0.0

03 m

05 m

20 m
0.0

SE 160 A

12.0 0.8

03 m

10 m

0.0

Bar

14.5 1.0

RETURN LINE FILTERS


RF SERIES

TECHNICAL DATA
STAUFF RF return line filters are designed as tank top filters. They are mounted directly on the tank top and
if 100 % of the system oil is filtered, they provide the optimum removal of contaminant from the system.
This provides the pump with clean oil thus reducing contaminant generated wear. The filter bowl is designed
to return oil beneath the tank oil surface thus preventing the entrainment of air by the returning oil.

Contamination Indicator
(optional)

Housing Cover

Flange Seal
Filter Element with
integrated Bypass Valve
Filter Bowl
Outlet

TECHNICAL SPECIFICATIONS/OPTIONS
Construction

Tank Top flange mounting

Filter head

Aluminum

Filter bowl

Steel

Seals

NBR Buna-N, FPM (Viton) or


EPDM (Ethylene-Propylene)

Threaded
connection

NPT- and
SAE-O-Ring thread
SAE-flange (3000 psi)

Max. Operating press.

230 psi (16 bar)

Proof pressure

350 psi (24 bar)

Temperature Range

-10C up to +100C
14F to 212

Bypass valve
(integrated in the
filter element)

Opening pressure
43 psi 4 psi (3 bar 0.3 bar)
Other pressures available on request

Contamination
indicator

Gauge indicator 0-58 psi


(0-4 bar) with colored segments
Electrical switch, setting 36 psi
(2.5 bar)

Filter elements

Filter material specification A, B, G, S:


Collapse rating per ISO 2941
430 psi (30 bar) p
Filter material specification D, N:
Collapse rating per ISO 2941
230 psi (16 bar) p

Media

Mineral oils
Other fluids on request
3/00

FILTRATION

Filter Head

94

RETURN LINE FILTERS


RF SERIES

OPTIONS

Visual contamination indicator

1. Visual contamination indicator


The gauge displays the degree of contamination of the element. The colored
segments allow quick visual checking.
green
0 -36 psi (0.0-2.5 bar)
Element has service life left
yellow
36-43 psi (2.5-3.0 bar)
Element is contaminated and
should be changed
red
> 43 psi (> 3.0 bar)
Bypass valve open, unfiltered oil
passing to tank
The contamination indicator can be mounted on the top or on the side of
the filter head (see drawing on page 96).
2. Electrical contamination switch

Electrical contamination switch

The switch is used where an electrical signal is needed to indicate


when the element needs changing. The switch can turn on a light,
or shut the machine down, or any other function controlled by an
electric signal. The switching pressure is 36 psi (2.5 bar) and this
allows the element to be changed before the bypass setting of 43 psi
(3.0 bar) is reached.
Switch Type
G 24V
G 110
G 220

3. Leakage oil connection

Leakage oil connection

Seal or case drain lines can be connected to the filter through


either of the contamination indicator ports providing that the
leakage oil can accept a pressure of 43 psi (3.0 bar.) It ensures
that no un-filtered oil returns to the reservoir.

4. Filter bowl with threaded connection

Threaded outlet

3/00

Under some circumstances such as a tall reservoir or one with


oil levels which vary greatly during operation, it is necessary to
extend the filter bowl so that the returning oil returns beneath the
surface and no air enters during the process. The optional bowl
with a female thread allows an extension to be fitted quite simply.

95

FILTRATION

Maximum Voltage
24 V
110 V
220 V

RETURN LINE FILTERS


RF SERIES

DIMENSIONS
h6

b4

b5

b3

G3
CODE 61 SAE FLANGE CONNECTION
(NOTE: CHECK CLEARANCE FROM TANK)

h5

h5

h3

h4

h1

h2

Ausbauma
fr
ELEMENT REMOVAL
CLEARANCE
f

b6

d3

G2

d2
THREADED OUTLET

FILTRATION

d1
POSITION 1

b 2 square

b 1 square

G4

d4
d5
Standard position for
contamination indicator
1.8 NPT

l1

MOUNTING DETAIL
POSITION 2

DIMENSIONS RETURN LINE FILTERS

RF 014

Dimensions
NPT

SAEflange

SAE-O
Ring
Port

/4

11/16-12 UNF

b1 b2
mm. 89

80

b3 b4

b5

b6 d1

d2

d3 d4

60

22 100 78

73

d5

h1 h2
33

RF 030

15/16-12 UNF

in. 3.50 3.15

2.87 2.36 0.87 3.94 3.07 1.3

RF 045

11/4

15/8-12 UNF

mm. 120 110

100 87

RF 070

11/2

17/8-12 UNF

in. 4.72 4.33

RF 090

17/8-12 UNF

mm. 150 135

RF 130

17/8-12 UNF

34 135 105

41

3.94 3.43 1.34 5.31 4.13 1.61

88 102 42.9 77.8 126 113 48.3 170 131

47

in. 5.91 5.31 3.46 4.02 1.69 3.06 4.96 4.45 1.90 6.69 5.16 1.85

96

h3

94
66 3.70
161.5
2.6 6.36
121
86 4.76
179
3.39 7.05
173
98 6.81
255
3.86 10.04

h4 h5 h6
155
6.10
222.5
8.76
207
8.15
265
10.43
271
10.67
353
13.90

l1

140
30 5.51 48
1.2 210 1.89
8.27
180
25 7.09 66
1.0 240 2.6
9.45
235
34 9.25 85
1.3 315 3.35
12.40

Wt.
G2 G3 G4 lbs. kg.
1
NPT

UNC

1 1/2
NPT

UNC

2
NPT

UNC UNC

/4

/16

/2

/8

2.0

.9

2.40 1.09
4.55 2.06
5.10 2.30
8.45 3.80
9.50 4.30

3/00

Filter
Size

RETURN LINE FILTERS


RF SERIES

ORDERING CODE FILTER HOUSINGS

RF 090 G10 B / N M2 L1
Filter type

RF
Group

SIZE
014
030
045
070
090
130

ADDITIONAL FEATURES

NOMINAL FLOW*
L/MIN
60
110
160
240
330
500

GPM
14
30
45
70
90
130

Pos.*

Drain line connection

Threaded outlet

* position of leakage oil connection see page 96


without any code: assembly in the middle of the filter cover

CONTAMINATION INDICATOR

Note: Exact flow will depend on filter


element selected. Consult Technical
Data on page 98 and 99.

Pressure gauge
Electrical switch 24 V
Electrical switch 110 V
Electrical switch 220 V

Pos.*

FOR COMPLETE FILTERS:

M
G 24
G 110
G 220

identification filter material


+ micron rating code

* position of contamination indicator see page 96


without any code: assembly in the middle of the filter cover

(see ordering code filter elements below)

SEAL MATERIAL
NBR - Buna-N
FPM - Viton
EPDM

CONNECTION STYLE

other seal material on request

GROUP

Code

Connection style

014

045

070

090

130

N
N1
U
U1

NPT
NPT
SAE-O-Ring thread
SAE-O-Ring thread
SAE-flange
(3000 psi)

/4
1
1 /4
3/
1
11/2
4
1
5
1 /16 1 /16 15/8
15/16 11/16 17/8

1 /2
11/4
17/8
15/8

2
11/2
17/8
15/8

2
11/2
17/8
15/8

030

ORDERING CODE FILTER ELEMENTS

RE 090 G 10 B

Seal material
B
NBR - Buna-N
V
FPM - Viton
E
EPDM
other seal materials on request

SERIES

RE
Micron rating

GROUP

03
05
10
20
25
40
60
100

according to filter housing

3/00

Filter material
Code
A
N, D
G, E
S, B

Material
Stainless fiber
Paper
Inorganic glass fiber
Stainless mesh

Micron ratings
available

p max
430 psi (30 bar)
03, 05,
230 psi (16 bar)
10, 20
430 psi (30 bar)
430 psi (30 bar) 25, 40, 60, 100

3 m
5 m
10 m
20 m
25 m
40 m
60 m
100 m

other micron ratings on request

Bold type identifies preferred material.

97

FILTRATION

B
V
E

PRESSURE DROP/ FLOW CURVES

FLOW CHARACTERISTICS OF RETURN LINE FILTERS


The following flow characteristics are valid for mineral oils with a specific gravity of 0.85 and the kinematic
viscosity of 141 SSU (30 cSt). The characteristics have been determined in accordance to
ISO 3968.
Housing
Filter
Size RFRF
014/030
Filtergehuse
Baugre
014/030

Housing
Filter Size RF 045/070
Filtergehuse Baugre RF 045/070

Psi

Bar

6.0 0.40

6.0 0.40

6.0

0.40

4.5 0.30

4.5 0.30

4.5

0.30

3.0 0.20

3.0 0.20

3.0

0.20

1.5 0.10

1.5 0.10

1.5

0.10

0.0

0.00

Psi

Bar

Psi

0.0 0.00

Bar

0.0 0.00
0
0

5.5
20

10.5
40

16.0
60
Q

21.0
80

26.0
100

32.0
120

GPM
LPM

0
0

10.5

21.0
80

40

32.0
120

42.0
160

52.0
200

62.5 GPM
240 LPM

Housing
Filter
Size RFRF
090/130
Filtergehuse
Baugre
090/130

26.0

52.0

78.0

104.0

130

GPM

100

200

300

400

500

LPM

ELEMENT FLOW CHARACTERISTICS


Psi Bar

Psi Bar

Psi

Bar

7.5 0.5

7.5

0.5

6.0 0.4

6.0 0.4

6.0

0.4

4.5 0.3

4.5 0.3

10 m

4.5

0.3

3.0 0.2

20 m

3.0

0.2

1.5

0.1

0.0

0.0

RE 014 A

10 m

3.0 0.2

20 m

1.5 0.1

1.5 0.1

0.0 0.0

0.0 0.0
0
0

Psi

Bar

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

16.0
60

0
0

GPM
LPM

RE 014 G

51.0 3.5
03 m

43.5 3.0
36.5 2.5

05 m

29.0 2.0
22.0 1.5

10.5
40

16.0
60
Q

21.0
80

26.0
100

32.0
120

GPM
LPM

Psi

Bar
4.0

51.0 3.5

51.0

3.5

43.5

3.0

36.5

2.5

RE 030 G

43.5 3.0
36.5 2.5

03 m

29.0 2.0

05 m

14.5 1.0

10 m

14.5 1.0

10 m

7.5 0.5

20 m

7.5 0.5

20 m

0.0 0.0
0
0

Psi

Bar

1.5

0.10

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

16.0
60

GPM

0
0

LPM

RE 014 N

Psi

Bar

1.5

0.10

1.2

0.08

.9

0.06

.6

0.04

5.5
20

10.5
40

16.0
60
Q

21.0
80

26.0
100

29.0

2.0

22.0

1.5

14.5

1.0

7.5

0.5

0.0

0.0

10 m

Psi

Bar

1.5

0.10

1.2

0.08

.9

0.06

.6

0.04

5.5
20

10.5 16.0 21.0 26.0 32.0 37.0 42.0


40 60
80 100 120 140 160
Q

03 m

05 m

10 m
20 m
5.5
20

10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM


40
60
80 100 120 140 160 L P M
Q

RE 045 N
10 m

10 m
1.2

0.08

.9

0.06

20 m

GPM
LPM

RE 045 G

0
0

32.0 GPM
120 LPM

RE 030 N

20 m

0
0

58.0

Bar

22.0 1.5

0.0 0.0

10 m

58.0 4.0

Psi

58.0 4.0

5.5
20

RE 045 A

20 m

20 m
.6

0.04

.3

0.02

.3

0.02

.3

0.02

0.0

0.00

0.0

0.00

0.0

0.00

0
0

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

16.0
60

0
0

GPM
LPM

Psi

RE 014 S

Bar

Psi

Bar

1.5

0.10

1.5 0.10

1.2

0.08

1.2 0.08

.9

25 m

0.06

5.5
20

10.5
40

16.0
60
Q

21.0
80

26.0
100

32.0
120

RE 030 S

25 m

.9 0.06

40 m

40 m
.6

0.04

.3

0.02

0.0

0.00

60 m

GPM
LPM

60 m

.6 0.04

100 m

100 m
.3 0.02
0.0 0.00
0
0

3.0
10

5.5
20

8.0
30
Q

10.5
40

13.0
50

16.0
60

GPM
LPM

0
0

5.5
20

10.5
40

16.0
60
Q

98

21.0
80

26.0
100

32.0
120

GPM
LPM

0
0

Psi

Bar

1.5

0.10

1.2

0.08

.9

0.06

5.5
20

10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM


40 60 80 100 120 140 160 LPM
Q

RE 045 S

25 m
40 m

.6

0.04

.3

0.02

0.0

0.00

60 m
100 m

0
0

5.5
20

10.5 16.0 21.0 26.0 32.0 37.0 42.0 GPM


40 60 80 100 120 140 160 LPM
Q

3/00

FILTRATION

RE 030 A

7.5 0.5

PRESSURE DROP/ FLOW CURVES

ELEMENT FLOW CHARACTERISTICS

Psi

Bar

Psi

Bar

7.5 0.5

7.5

0.5

7.5

0.5

6.0 0.4

6.0

0.4

6.0

0.4

4.5

0.3

4.5

0.3

3.0

0.2

1.5

0.1

0.0

0.0

Psi Bar

RE 070 A

4.5 0.3

10 m

3.0 0.2

20 m

1.5 0.1
0.0 0.0
0
0

Psi

Bar

10.5
40

21.0
80

32.0
120
Q

42.0
160

52.0
200

3.0

0.2

1.5

0.1

0.0

0.0

62.5 GPM
240 LPM

RE 090 A

10 m
20 m

0
0

29.0
110

58.0
220

86.0
330

Psi

RE 070 G

51.0 3.5

20 m

0
0

GPM
LPM

Bar

RE 090 G

58.0 4.0

Psi Bar
58.0 4.0

51.0 3.5

51.0 3.5

03 m

43.5 3.0

36.5 2.5

05 m

36.5 2.5

03 m

36.5 2.5

29.0 2.0

29.0 2.0

05 m

29.0 2.0

22.0 1.5

22.0 1.5

7.5 0.5
32.0
120
Q

42.0
160

52.0
200

05 m

7.5 0.5

20 m

10 m

7.5 0.5

Bar

1.2

0.08

.9

0.06

0.04

.6

.3

0.02

.3

.0

0.00

0.08

.9

0.06

.6

20 m

.0
0
0

Psi

Bar

1.5

0.10

1.2

0.08

.9

0.06

10.5
40

21.0
80

32.0
120
Q

42.0
160

52.0
200

29.0

110

58.0

86.0

GPM

220

330

LPM

.0

0.00

25 m
60 m

10.5
40

21.0
80

32.0
120
Q

52.0
200

Psi

Bar
0.10

1.2

0.08

.9

0.06

0.04

.6

0.04

0.02

.3

0.02

0.00

.0

0.00

RE 090 N
10 m

20 m

0
0

29.0
110

Psi

Bar

1.5

0.10

1.2

0.08

.9

42.0
160

52.0
200

62.5
240

GPM
LPM

78.0
300

104.0
400

58.0
220

86.0
330

10 m

20 m

0
0

GPM
LPM

26.0
100

52.0
200

78.0
300

104.0
400

RE 090 S

25 m

0.06

60 m

0.04

Psi

Bar

1.5

0.10

0.02

.0

0.00
0
0

29.0
110

58.0
220
Q

99

GPM
LPM

1.2

0.08

.9

0.06

RE 130 S

25 m
40 m

.6

60 m

0.04

100 m

100 m
.3

130.0
500

40 m
.6

130.0 GPM
500 LPM

RE 130 N

RE 070 S

0
0

26.0
100

100 m
0.02

0
0

1.5

62.5 GPM
240 LPM

0.04

.3

20 m

0.0 0.0
0

40 m
.6

03 m

14.5 1.0

0.10

1.2

RE 130 G

10 m

GPM
LPM

22.0 1.5

62.5 GPM
240 LPM

RE 070 N

130.0
500

10 m

Psi

Bar
0.10

104.0
400

14.5 1.0

1.5

Psi
1.5

78.0
300

43.5 3.0

0.0 0.0

0.0 0.0
21.0
80

52.0
200

86.0
330

GPM
LPM

.3

0.02

.0

0.00
0
0

26.0
100

52.0
200

78.0
300
Q

104.0
400

130.0 GPM
500 LPM

FILTRATION

10 m
20 m
10.5
40

26.0
100

43.5 3.0

14.5 1.0

3/00

10 m

58.0 4.0

0
0

RE 130 A

RETURN LINE FILTERS


RTF 10/25 SERIES

SPECIFICATIONS

OPTIONS

Flows to 25 gpm

For RTF25 series

Working Pressure

10 or 25 micron paper elements

RTF1050 psi (3.4 bar)

10 micron inorganic fiber 10>


_75

RTF 25100 psi (6.9 bar)

For RTF10 series, 20m paper

For use with mineral and

element available only

petroleum based fluids only

Visual and Electrical indicators

By-Pass in element 25 psi (1.6 bar)

Two bowl lengths for RTF25

Operating temperature

Special threads/special bowl

-13oF to 212oF

lengths/special elements

-25oC to 100oC

available on request

Aluminum die casting

DIMENSIONS

TYPE

RTF 10
RTF 25

INLET PORT

BOWL
LENGTH

1/2 NPT

S1

in
mm

1 NPT or
1 5/16 SAE

S1
S2

in
mm
in
mm

3.2
82

5.08
129

2.6
66

0.3
8

1.02
26

3.6
5.4

92 6.1
137 7.9

0.94
24
155 3.4
86 0.4
10 1.34
34 1.1
86
10
34
28
200

100

0.83
21
1.14
29

1.97
50
2.63
67

0.28
7
0.35
9

3.54
90
4.52
115

Weight
lbs.

kgs.

1.0

0.45

2.0
2.2

0.9
1.0

3/00

FILTRATION

Buna-N seals

RETURN LINE FILTERS


RTF 10/25 SERIES

PRESSURE DROP RTF 10/25

FILTER ELEMENTSRTF 10 SERIES


0.5
6.0

1/2"

0.3

4.5

1"

0.2

3.0

0.1

1.5

gpm 0
lpm 0

20
75

40
150

60
225

80
300

ON

0.4

0.3

4.5

0.2

3.0

0.1

1.5

gpm 0
lpm 0

100
375

6.0

ICR
m
0M

5
20

10
40

15
60

20
80

PSI

PRESSURE DROP BAR

0.4

PSI

PRESSURE DROP (BAR)

FILTER HEAD RTF 10/25 SERIES


0.5

25
100

FLOW

FLOW

FILTER ELEMENTSRTF 25 SERIES


0.4
0.3

6.0
4.5

10

0.2

3.0

0.1

1.5

gpm 0
lpm 0

5
40

10
80

15
120

20
160

FILTRATION

All curves on
141 SSU (30 cts)
viscosity oil @ 100F

r
r
pre
ppae
be
icfi
opna
r
c
r
n
c
i
i
erpe
gna
mm
appa
ogra
1100
rpon
ionr
m
c
i
n

i
5m
10
225
m

PSI

PRESSURE DROP BAR

0.5

25
200

FLOW

ORDERING INFORMATION

RTF

25N

xxx

S2

FILTER TYPE

INDICATOR

RTF

N
V
E

PORT SIZE
10N
25N
25S

2" NPT
1" NPT
1516"-12 SAE

None
CI-20 Visual Indicator
EPS-1 Electrical Indicator

BOWL LENGTH
S1
S2

Bowl length 1
Bowl length 2

Buna-N

SEAL MATERIAL

ORDERING CODE - FILTER ELEMENTS

3/00

RTE10
RTE25
RTE25
RTE25
RTE25

D
D
D
D
G

20
10
10
25
10

B
B
B
B
B

/
/
/
/
/

S1
S1
S2
S2
S2

20
10
10
25
10

Micron
Micron
Micron
Micron
Micron

nominal paper
nominal paper / S1 bowl length
nominal paper / S2 bowl length
nominal paper / S2 bowl length
(10 ,75) Inorganic fiber / S2 bowl length

See page 136 for more details on the Indicator options.

101

RETURN LINE FILTERS


RTF 47 SERIES

SPECIFICATIONS
Flows to 55 gpm
Working Pressure 100 psi (6.9 bar)
For use with mineral and petroleum
based fluids only
By-Pass in element 25 psi (1.6 bar)
Operating temperature
-13oF to 212oF
-25oC to 100oC
Aluminum die casting
Buna-N seals
1 14 NPT / 1 12 SAE 4 bolt flange part

OPTIONS
Elements
-10 micron paper 10 >
_2
_ 75
-10 micron inorganic fiber 10 >

DIMENSIONS

WEIGHT

IN

9.3

11.9

4.4

0.45

1.9

1.6

1.9

6.7

5.9 Lbs

MM

236

302

112

11.4

48

41

48

170

2.6 kg

102

3/00

FILTRATION

Special threads and bowl length available on request.

RETURN LINE FILTERS


RTF 47 SERIES

PRESSURE DROP/FLOW RTF 47 SERIES

RTF 47 FILTER HEAD

0.5

psi

0.4

PRESSURE DROP BAR

PRESSURE DROP BAR

0.5

6.0

1 1/4" NPT / 1 1/2" FLANGE

0.3

4.5

0.2

3.0

0.1

1.5

Flow gpm 0
lpmlpm 0

40
150

80
300

RTF 47 FILTER ELEMENTS


cer
nfiib

on
igna
or
0
n
i
1
m
10

0.4
0.3

rpoa

ic
m

m
1100

ar
nppe

psi
6.0
4.5

0.2

3.0

0.1

1.5

Flow gpm 0
lpmlpm 0

120
450

pe

a
rigc

20
75

40
150

60
225

80
300

FILTRATION

ORDERING INFORMATION

RTF

47N

xxx

S1

FILTER TYPE

INDICATOR

RTF

N
V
E

PORT SIZE
47N

None
CI-20 Visual Indicator
EPS-1 Electrical Indicator

BOWL LENGTH

1 1/4" NPT / 1 1/2SAE FLANGE

S1

Bowl length 1

Buna-N

SEAL MATERIAL

ORDERING CODE - FILTER ELEMENTS

3/00

RTE47 D 10 B / S1
RTE47 G 10 B / S1

10 Micron nominal paper, (10 2) S1 bowl length


10 Micron Inorganic fiber, (10 75) S1 bowl length

See page 136 for more details on the Indicator options.

103

RETURN LINE FILTERS


RTF 20 SERIES

SPECIFICATIONS
Flows up to 30 gpm (110 lpm)
Die-cast aluminum head with a
polyamid screw-on cap and bowl
Combination filter, breather and filler
Maximum working pressure 145 psi (10 bar)
For use with mineral and petroleum
based fluids only
By-pass in element 25 psi (1.6 bar)
Operating Temperature -13F to 212F
-25C to 100C
10 filler breather
Buna - N Seals
Filter Element Collapse rating 75psi (5 bar)

OPTIONS
12 NPT, 34 NPT, -8 SAE, -12 SAE Ports
Elements

10 Paper
6 inorganic glass fiber
10 inorganic glass fiber

Electrical or Visual indicators available


Dipstick Available
40 paper breather element
Special elements available on request

DIMENSIONAL INFORMATION
L

R
M

H
J

RF20

in

7.95

1.61

2.95

7.01

0.94

mm

202

41

75

178

24

4 NPT

or SAE

min 2.36
max 2.48
min 60mm
max 63mm

104

0.63

1.1

1.97

2.76

0.43

3.46

3.23

3.03

16

28

50

70

11

88

82

77

3/00

FILTRATION

20 inorganic glass fiber

PRESSURE DROP / FLOW CURVES


RTF 20 SERIES

RTF 20 FILTER ELEMENTS

RTF 20 FILTER HEAD


0.5

0.5

7.5

1/
2

3.0

3/
4

1.5

10
38

20
76

PSI

10
m

m
10

0.4

0.3

r
pe
pa

0.2

3.0

0.2

0.1

1.5

0.1

40 gpm
152 lpm

30
114

4.5

m
20

ic
an
rg
o
in

er
fib

10
38

5
19

FLOW

15
76

BAR

0.3

4.5

6m
ino
rga
nic
fibe
r

6.0

0.4

BAR

PSI

6.0

in
or
ga
ni
c

fib
er

7.5

20 gpm
114 lpm

FLOW

VISCOSITY - 141 SSU (30 CS). TEMPERATURE - 100F (38C)


FILTRATION AREA (cm2)

FLOW RATES FOR FILLER BREATHER CARTRIDGE

10m

40m

RTF20

BETA
RATIO

gpm

30.0

42

10m paper

870

B10 2

0.05 bar

lpm

114

160

6m glass fiber

710

B6 75

1.4 psi

gpm

50

66

10m glass fiber

710

B10 75

0.10 psi

lpm

190

250

20m glass fiber

710

B20 75

DIRT HOLDING CAPACITY

ACFTD DHC (gms) p = 1.3 BAR (19 psi)


5

10m glass fiber

20m glass fiber

3/00

6m glass fiber

105

FILTRATION

0.7 psi

ORDERING INFORMATION
RTF 20 SERIES

ORDERING INFORMATION-COMPLETE FILTER

RTF20

N1

G 10 B

B 40

FILTER TYPE

DIPSTICK

RTF 20

No Dipstick
Dipstick

BREATHER
B10 10 micron
B40 40 micron

THREAD TYPE

INDICATOR

2" NPT
3
4" NPT
3
4"- 16 SAE
1116"-12 SAE
1

N
N1
V
E

No Indicator
No Indicator - Hole Drilled
Visual Indicator
EPS-1 Electrical Indicator

ORDERING CODE-FILTER ELEMENT

RTE20

10

FILTER TYPE
RTE 20

SEAL
B
V

MICRON RATING

FILTER MEDIA
D
G

Buna-N
Viton

6
10
20

Paper
Inorganic glass fiber

See page 136 for more details on the Indicator options.

106

6 micron
10 micron
20 micron

3/00

FILTRATION

N1
N2
S1
S2

RETURN LINE FILTERS


RTF 30 SERIES

SPECIFICATIONS
Flows up to 40 gpm (152 lpm)
Die-cast aluminum head with a
polyamid screw-on cap and bowl
Combination filter, breather and filler
Maximum working pressure 145 psi (10 bar)
For use with mineral and petroleum
based fluids only
By-pass in element 25 psi (1.6 bar)
Operating Temperature -13F to 212F
-25C to 100C
10 filler breather
Buna - N Seals
Filter Element Collapse rating 75psi (5 bar)

OPTIONS

3/
4

NPT, 1 NPT, -12 SAE, -16 SAE Ports

3 Bowl lengths 4.33 in (110mm)


6.9 in (175mm)
10.8 in (275mm)
4 Elements

10m paper

FILTRATION

6m inorganic fiber
10m inorganic fiber
20m inorganic fiber
Electrical or Visual Indicators available
Dipstick available
40 paper filler breather element
Special elements available on request.

DIMENSIONAL INFORMATION
K

1.5

90

J
3/00

107

PRESSURE DROP/ FLOW CURVES


RTF 30 SERIES

RTF31
RTF32

in

5.51

2.36

4.09

4.33

1.18

3/
4

0.87

1.42

2.76

3.27

0.43

4.53

4.33

4.06

mm

140

60

104

110

30

or 1

min. 3.43

22

36

70

83

11

115

110

103

in

8.07

2.36

4.09

6.89

1.18

3/
4

max. 3.58

0.87

1.42

2.76

3.27

0.43

4.53

4.33

4.06

mm

205

60

104

175

30

or 1

min. 87mm

22

36

70

83

11

115

110

103

in

12.01

2.36

4.09

10.83

1.18

3/
4

max. 91mm

0.87

1.42

2.76

3.27

0.43

4.53

4.33

4.06

mm

305

60

104

275

30

or 1

22

36

70

83

11

115

110

103

0.4

6.0

0.2

3.0
3/
4

0.1

20
76

10
38

4.5

3.0

F
RT

0.3

31

0.2

1.5

40 gpm
152 lpm

30
114

0.4
2
F3
RT
30

PSI

0.3

4.5

PRESSURE DROP

6.0

0.5

BAR

PSI

7.5

1.5

FILTRATION

RTF 30/31/32 FILTER ELEMENTS - 10 MICRON PAPER

0.5

BAR

PRESSURE DROP

RTF 30/31/32 FILTER HEAD


7.5

R
TF

RTF30

0.1

20
76

10
38

FLOW

30
114

40 gpm
152 lpm

FLOW

VISCOSITY - 141 SSU (30 CS). TEMPERATURE - 100F (38C).

1.5

0.1

20
76

31
TF
R

RT
F

4.5

3.0

0.3

0.2

1.5

40 gpm
152 lpm

30
114

0.4

0.1

20
76

10
38

FLOW

30
114

40 gpm
152 lpm

FLOW

RTF 30/31/32 FILTER ELEMENTS - 20 MICRON GLASS FIBER


7.5

0.5

6.0

0.4

F
RT

31

3.0
TF
R

1.5

0.2

2
F3
RT

30

BAR

0.3

4.5

0.1

10
38

20
76

FLOW

108

30
114

40 gpm
152 lpm

3/00

10
38

PSI

0.5

32

RT
F3
0

31
RT
F
32

RT
F

0.2

PRESSURE DROP

PSI

6.0

0.3

RT
F3
0

3.0

0.4

RTF 30/31/32 FILTER ELEMENTS - 10 MICRON GLASS FIBER

BAR

4.5

7.5

BAR

PRESSURE DROP

6.0

0.5

PSI

RTF 30/31/32 FILTER ELEMENTS - 6 MICRON GLASS FIBER

PRESSURE DROP

7.5

ORDERING INFORMATION
RTF 30 SERIES

FLOW RATES FOR FILLER BREATHER CARTRIDGE

10

40

FILTRATION AREA (CM2)

RTF 30

DIRT HOLDING CAPACITY

RTF31

RTF32

Beta Ratio

0.7psi

gpm

30.0

42.1

10m
paper

940

1500

1850

B10 2

0.05bar

lpm

114

160

6m fiber

670

1020

1670

B6 75

1.4psi

gpm

50.0

66

10m fiber

670

1020

1670

B10 75

0.10bar

lpm

190

250

20m fiber

670

1020

1670

B20 75

ACFTD DHC (gms) at p = 1.3 BAR (19 psi)


RTF30

RTF31

RTF32

6m glass fiber

11

10m glass fiber

15

20m glass fiber

11

17

ORDERING INFORMATION-COMPLETE FILTER

RTF31

N2

G 10 B

B 40

FILTER TYPE
RTF 30

DIPSTICK
D

Bowl length
4.33
Bowl length
6.89
Bowl length
10.83

RTF 31
RTF 32

No Dipstick
Dipstick

BREATHER

THREAD TYPE
N1
N2
S1
S2

INDICATOR

4 NPT
1" NPT
1116-12 SAE
1516-12 SAE
3

N
N1
V
E

No Indicator
No Indicator - Hole Drilled
Visual Indicator
EPS - 1Electrical Indicator

ORDERING CODE-FILTER ELEMENT

RTE

31

10

SERIES
RTE

SEAL
B
V

Buna-N
Viton

FILTER GROUP
30
31
32

Bowl Lengths 4.33


Bowl Lengths 6.9
Bowl Lengths 10.8

MICRON RATING
6 6 micron
10 10 micron
20 20 micron

FILTER MATERIAL
D

3/00

Paper
Inorganic
Glass fiber

See page 136 for more details on the Indicator options.

109

FILTRATION

B10 10 micron
B40 40 micron

RETURN LINE FILTERS


TEF 625 SERIES

SPECIFICATIONS

OPTIONS

Flows to 165 gpm (625 lpm)

3, 10, 25 Micron glass fiber elements

2 SAE Flange (3000 psi)

Stainless steel mesh available on

Port Connection

special request

Working Pressure 145 psi (10 bar)

Buna-N or Viton Seals

All elements are 200 rated

Visual and Electrical Indicators available

By-Pass in filter element 29 psi (2 bar)


Glass fiber reinforced polyamid bowl
Normal operating temperature
-14oF to 176oF (-25oC to 80oC)

FILTRATION

DIMENSIONS

ORDERING INFORMATION

TEF

625

10VG16 S

FILTER TYPE

CLOGGING INDICATOR

TEF - IN TANK RETURN

V
E1

VISUAL
ELECTRICAL

NOMINAL FLOW
SEAL MATERIAL

625 LPM-165 GPM


P
V

Buna-N
Viton

ORDERING CODE - FILTER ELEMENTS


01.E 631.3VG.16 S P
01.E 631.10VG.16 S P
01.E 631.25VG.16 S P

3 Micron inorganic fiber


10 Micron inorganic fiber
25 Micron inorganic fiber
3/00

625

110

RETURN LINE FILTERS


TEF 950 SERIES

SPECIFICATIONS

OPTIONS

Flows to 250 gpm (950 lpm)

3, 10, 25 Micron glass fiber elements

3 SAE Flange (3000 psi)

Stainless steel mesh available on

Port Connection

special request

Working Pressure 145 psi (10 bar)

Buna-N or Viton Seals

All elements are 200 rated

Visual and Electrical Indicators available

Steel bowl
By-Pass in filter element 29 psi (2 bar)
Normal operating temperature
-14oF to 176oF (-25oC to 80oC)

DIMENSIONS

FILTRATION

ORDERING INFORMATION

TEF

951

10VG10 S

FILTER TYPE

CLOGGING INDICATOR

TEF - IN TANK RETURN

V
E1

VISUAL
ELECTRICAL

NOMINAL FLOW
950

SEAL MATERIAL

950 LPM-250 GPM


P
V

Buna-N
Viton

ORDERING CODE - FILTER ELEMENTS


3 Micron inorganic fiber
10 Micron inorganic fiber
25 Micron inorganic fiber

3/00

01.E 950.3VG.10 S P
01.E 950.10VG.10 S P
01.E 950.25VG.10 S P

111

FILTER ELEMENTS

REPLACEMENT FILTER ELEMENTS FOR SF AND RF SERIES

FILTRATION

STAUFF replacement filter elements for SF and RF series filters are manufactured in the common filter
materials such as stainless fiber, stainless mesh, polyester fiber, paper, and inorganic glass fiber.
All replacement elements made by STAUFF comply with quality specifications in accordance with
international standards.

ORDERING CODE FILTER ELEMENTS

SE 014 G 10 V
Series
SE

for pressure filters SF

RE

for return line filters RF

Seal material
B
NBR - Buna-N
V
FPM - Viton
E
EPDM
other seal materials on request

Group
according to filter housing

Code
A
C
N, D
G, E
H, F
B, S
T, W

Material
Stainless fiber
Polyester fiber
Paper
Inorganic glass fiber
Inorganic glass fiber
Stainless mesh
Stainless mesh

SE
p max
3000 psi (210 bar)
3000 psi (210 bar)
430 psi (30 bar)
430 psi (30 bar)
3000 psi (210 bar)
430 psi (30 bar)
3000 psi (210 bar)

RE

Micron ratings
available

p max
430 psi (30 bar)

03, 05,
230 psi (16 bar)
10, 20
430 psi (30 bar)

430 psi (30 bar)


25, 40, 60, 100

03
05
10
20
25
40
60
100

3 m
5 m
10 m
20 m
25 m
40 m
60 m
100 m

other micron rating on request


3/00

Filter material

Micron rating

Bold type identifies preferred material

112

FILTER ELEMENTS

INTERCHANGE FILTER ELEMENTS


STAUFF manufactures interchange filter elements for a wide range of filter manufacturers. They meet the
technical requirements with regard to quality and dimensions and consequently can be used with
confidence in the installations.

FILTRATION

Continuing research and development of filter


materials used by STAUFF, and observance of strict
Quality Assurance procedures together with the
relevant international standards, ensures consistently
high performance of our filter elements.

3/00

STAUFF manufacturing and stocking policies are


designed to give our customers ready access to a
wide range of filter elements from one source.

Interchange filter elements are available to suit


housings of the following manufacturers:
Argo
Eppensteiner
Internormen
Hydac/Hycon
Mahle
Pall
Fairey
MP Filtri
Special elements are available on request.
Please consult factory.

Consult www.stauffusa.com for a complete


interchange guide.

113

FILTER ELEMENTS

FILTER MATERIAL SPECIFICATIONS


Stainless Metal fiber
Material specification A
collapse/burst resistance as per ISO 2941: 3000 psi (210 bar) (Pressure filters)
collapse/burst resistance as per ISO 2941: 430 psi (30 bar) (Return line filters)
Sintered stainless metal fiber with a three dimensional labyrinth structure
for depth filtration.
Low flow resistance with a high dirt holding capacity.
Excellent chemical and thermal resistance.

Metal fiber

Stainless wire mesh


Material specification B, S

collapse/burst resistance as per ISO 2941:


430 psi (30 bar)
Material specification W, T collapse/burst resistance as per ISO 2941:
3000 psi (210 bar)

Stainless wire mesh

Polyester fiber
Material specification C collapse/burst resistance as per ISO 2941:
3000 psi (210 bar)
100% polyester fiber with fibers thermally bonded creating
a tearproof material with no electrostatic charging.
Exceptional shear strength.
Depth filtration gives large dirt holding capacity with low flow
resistance.
Good chemical resistance.
High filtration efficiency even on small particle sizes.

Polyester fiber

Paper
Material specification D, N
collapse/burst resistance as per ISO 2941: 430 psi (30 bar) (Pressure filters)
collapse/burst resistance as per ISO 2941: 230 psi (16 bar) (Return line filters)
Filter material made from impregnated cellulose paper.
Low cost design with good dirt holding capacity.
Not suitable for use with any water based fluids.

Paper

Inorganic glass fiber


Material specification G, E collapse/burst resistance as per ISO 2941:
430 psi (30 bar)
Material specification H, F collapse/burst resistance as per ISO 2941:
3000 psi (210 bar)
Non-woven glass fiber material with acrylic resin bond.
High dirt holding capacity.
High filtration efficiency, even on small particle sizes,
achieved by the depth filtration produced by the three
dimensional labyrinth structure of the material.
Excellent cost effectiveness.
Material specifications G and H are the updated high performance elements
and should be selected for new applications.

114

Inorganic glass fiber

3/00

FILTRATION

Woven stainless steel wire in 1.4301/1.4404 grade with a square


mesh or double milled twill lace weave.
Low flow resistance.
Surface filtration. Excellent chemical and thermal resistance.

FILTER ELEMENTS

STAUFF FILTER ELEMENTS


are tested according to
ISO 2943
Compatibility with hydraulic fluids

ISO 2942
Proof of integrity and quality (Bubble point test)

ISO 3968
Flow characteristics

ISO 3723
Verification of the end cap stress

ISO/DIN 3724
Flow fatigue characteristics

ISO 2941
Collapse / burst pressure verification

ISO/DIN 4572
Filter performance test (Multi-pass test)

FILTRATION

Multi-pass-test stand

Multi Pass Testing (Beta Ratio)


The Beta Ratio (x) is considered one of the most important criteria in assessing the capability of a filter to remove
contaminant particles. This value is determined by means of the multi-pass test, according to ISO/DIN 4572.

Definition :

The Beta Ratio is the ratio of the number of particles, greater than a given size, upstream of the
filter to the number of particles, greater than the same size, downstream of the filter in the same size
fluid sample.
x = Number of particles > xm upstream
(x = particle size)
Number of particles > xm downstream

The Beta Ratio can be used to calculate the Filter Efficiency Rating by the following formula.
Ex = x - 1 x 100
x

Ratio vs Efficiency

Ex = % efficiency

Example for a given particle size of 10 m

3/00

10 = 9360 = 208
45

E10 = 208 - 1 x 100 = 99.52 %


208

NOTE: All STAUFF inorganic glass fiber filter elements have a Beta Ratio > 200
at their rated micron rating.

115

Ratio

Efficiency

1
2
20
50
75
100
200
1.000
10.000

0
50%
95%
98.00%
98.67
99.00%
99.50
99.90%
99.99%

TECHNICAL APPENDIX

CHOICE OF FILTERS
Choice of a suitable micron rating
Generally, the type of components incorporated in
the hydraulic system will determine the micron
rating required. It has been clearly demonstrated
that system components will operate reliably for
years if a specific minimum oil cleanliness
grade is maintained. Frequently the choice will be
determined by the most sensitive component
in the system.

Choice of the optimum filter


In selecting the filter, the following information
must be considered:
maximum flow volume (Qmax) through the filter
including surge flows
kinematic viscosity () of the fluid in SSU
at cold start temperature and operating
temperature
micron rating (m): see table

a) Operating filter

filter material
The aim is to choose a filter whose total
differential pressure (p) is no greater than
pmax = 14.5 psi (1.0 bar) for pressure filters or
pmax = 7.5 psi (0.5 bar) for return line filters, in a
clean state at the normal operating temperature.
These values have been proven in practice to give
the optimum service life for the element.
The nominal flow volume of the filter is the
obvious reference value for pre-selection and this
should be larger than the flow to be filtered.
Qnom > Qmax

Oil cleanliness Micron


grade as per
rating
ISO 4406

Area of Application

13/10
16/13
18/15
19/16

servo valve hydraulics


proportional hydraulics
standard hydraulics >100 bar
standard hydraulics <100 bar

3
5
10
20

m
m
m
m

Calculations based on the filter data will verify


whether the pre-selected filter meets the
requirements, at operating temperatures:
pmax < 14.5 psi (1.0 bar) (for pressure filter)
pmax < 7 psi (0.5 bar) (for return line filter)
The total differential pressure is the sum of the
differential pressure values of the empty housing
and the filter element. They are calculated from
the flow characteristics tables.
ptotal = phous + pelem

b) Protective filter
Occasionally, protective filters are fitted
downstream of major components, eg., the pump,
to collect the debris in case of a catastrophic
failure. This avoids total stripping and flushing of
the system. For economic reasons, protective filters
are normally one grade coarser than the operating
filters since they do not significantly contribute to
the cleaning of the system and this extends filter
service intervals.

The flow characteristic tables are based on a


kinematic viscosity of 30 centistokes (141 SSU).
For different viscosities, a correction factor (K)
based on the following formula must be applied
to the figure calculated at 30 centistokes (141 SSU).

K=

141

141

The operating differential pressure is then


calculated by the following formula:
poperating = pnom + K x pelem
The filter size is suitable if the poperating < pmax.
If the calculated poperating is greater than pmax,
select the next larger filter size and re-calculate
until a satisfactory solution is found.
The following two examples explain the procedure.

116

3/00

FILTRATION

The following chart is a general guide but the final


result should be checked by oil analysis. Apart from
the specific flow rate (gpm/in2 of filter area), other
factors such as operating environment and
condition of seals and breathers can have an effect
on the cleanliness grade which can actually be
achieved.

TECHNICAL APPENDIX

EXAMPLES OF CALCULATION

or

= 2.1 psi

+ 1.39 x 8.1 psi = 13.4 psi pmax = 14.5 psi

In a clean state, this filter fulfills the requirements and is suitable for the application.
The correct filter designation is: SF090G10BTB/BV

3/00

Example 2: Selection of a return line filter


System Information. A return line filter with a paper element is required to clean the oil.
No contamination indicator is required.
N. B.
If the system incorporates either accumulators or cylinders, the return flow can
dramatically exceed pump flow and the maximum surge flow should be the flow
used to calculate the pressure drop through the filter.
Data given:
Qmax = 24 gpm (90 lpm)
operating = 150 SSU (32 cSt)
Micron rating 20 m (see table page 14)
First Step
Pre-selection:
Size RF 030, Qnominal = 30 gpm > Qmax (29 gpm)
Pressure drop values at viscosity of 141 SSU (30 cSt) from the flow characteristics:
phous
= 4 psi (0.27 bar)
(RF 030 , page 14)
pelem
= 0.6 psi (0.04 bar)
(RE 030 N 20 B, page 14)
Determination of the correction factor (see page 14)
SSU 150
centistokes 32
+
32
+
150
K = 30
30 = 1.05
K = 141
141 = 1.05
2
2
Determination of the actual pressure drop:
pactual = phous + K pelem = 0.27 bar + 1.05 x 0.04 bar = 0.31 bar < pmax = 0.5 bar
or = 4 psi
+ 1.05 x 0.6 psi = 4.6 psi pmax = 7.5 psi
In a clean state, this filter fulfills the requirements and is suitable for the application. No further
calculation is necessary.
The correct filter designation is: RF030N20B/B
Consult factory for the Stauff Filter Specification and Sizing Diskette for both SF and RF filters.

117

FILTRATION

Example 1: Selection of a pressure filter


System Information. A pressure filter with an inorganic glass fiber element is required immediately after
the pump. The system has standard components and is operating at pressures up to 3000 PSI (200 bar).
The filter shall be fitted with a bypass valve and a visual contamination indicator.
Data given:
Qmax = 45 gpm (170 lpm)
operating = 213 SSU (46 cSt)
Micron rating 10 m (see table on page 8&9)
First Step
Pre-selection:
Size SF 070, Qnominal = 70 gpm > Qmax
Pressure drop values at viscosity of 141 SSU (30 cSt) from the flow characteristics:
phous
= 3.6 psi (0.25 bar)
(SF 070 , see page 7)
pelem
= 12 psi (0.8 bar)
(SE 070 G 10 B, see page 9)
Determination of the correction factor (see page 9)
SSU 213
centistokes 46
+
46
+
213
30
30 = 1.39
141
141
K=
K=
= 1.39
2
2
Determination of the actual pressure drop:
pactual = phous + K pelem = 0.25 bar + 1.39 x 0.80 bar = 1.36 bar > pmax = 1.0 bar
3.62 psi + 1.39 x 11.6 psi = 19.7 psi > pmax = 14.5 psi
Since the actual pressure drop is larger than the allowed pressure drop, a larger filter has to be chosen.
Second Step
Selection of the next larger filter size; SF 090, Qnominal = 90 gpm > Qmax
phous
= 2.1 psi (0.15 bar)
(SF 090 , see page 7)
pelem
= 8.7 psi (0.6 bar)
(SE 090 G 10 B, see page 9)
Actual pressure drop pact = phous + K pelem = 0.15 bar + 1.39 x 0.6 bar = 0.99 bar pmax = 1.0 bar