Physical Description
The Port Status LEDs and Power Inputs
Users Manual
DC Jack
Terminal Block
Earth Ground
DIP Switch Assignment
Loc
The device operates in local mode
Rmt
The device operates in remote mode
LEDs
State
Indication
Power1
Power2
Power3
Steady
Power on
Off
Power off
Steady
Ethernet
Link/ACT
FDX
Users Manual
Steady
Off
Error
Error occurred
Link
DC Terminal Block Power Inputs: There are two pairs of power inputs can
be used to power up this Ethernet Extender. Redundant power supplies
function is supported. You only need to have one power input connected to
run the Ethernet Extender.
DC JACK Power input: 12VDC.
Functional Description
Users Manual
Console Configuration
Users Manual
Web Configuration
Users Manual
Users Manual
Preface
This manual describes how to install and use the Hardened Managed
Ethernet Extender. The Hardened Managed Ethernet Extender introduced
here provides one channel for Ethernet over existing voice grade copper
wire.
The Hardened Managed Ethernet Extender fully complies with IEEE802.3
10Base-T and IEEE802.3u 100Base-TX/FX standards.
In this manual, you will find:
Product overview
Features on the Hardened Managed Ethernet Extender
Illustrative LED functions
Installation instructions
Management Configuration
Specifications
Users Manual
Table of Contents
Quick Start Guide ......................................................................... 1
Physical Description .................................................................... 1
The Port Status LEDs and Power Inputs.................................... 1
Functional Description................................................................. 3
Assembly, Startup, and Dismantling............................................. 4
Console Configuration ................................................................. 4
Web Configuration ....................................................................... 5
Preface............................................................................................ 7
Table of Contents .......................................................................... 8
Introduction ................................................................................. 10
Product Overview....................................................................... 10
Product Features ........................................................................ 10
Packing List................................................................................ 11
One-Channel Hardened Managed Ethernet Extender ............ 12
Ports ........................................................................................... 12
Ethernet Extender Mode Settings ............................................... 12
DIP switch .................................................................................. 12
Front Panel & LEDs .................................................................. 13
Installation ................................................................................... 16
Selecting a Site for the Equipment.............................................. 16
Wiring Diagram ......................................................................... 16
DIN Rail Mounting ..................................................................... 17
Connecting to Power .................................................................. 18
12VDC DC Jack ...................................................................... 18
Redundant DC Terminal Block Power Inputs ......................... 18
Web-Based Browser Management............................................. 19
Logging on to The Hardened Managed Ethernet Extender........ 19
IP Address................................................................................ 19
Password.................................................................................. 19
Understanding the Browser Interface ........................................ 19
Basic Settings ............................................................................. 21
Network Settings ..................................................................... 21
Server Name Settings .............................................................. 22
NTP Server Settings ................................................................ 23
Advanced Settings....................................................................... 24
Lan Settings ............................................................................. 24
VDSL Settings......................................................................... 24
Users Manual
Users Manual
Introduction
The Hardened Managed Ethernet Extender provides one channel for
Ethernet over existing voice grade copper wire. This Hardened Managed
Ethernet Extender solution is perfectly fitted in the industrial applications or
rugged environment.
Product Overview
Product Features
Users Manual
10
Packing List
When you unpack this product package, you will find the items listed below.
Please inspect the contents, and report any apparent damage or missing
items immediately to our authorized reseller.
Users Manual
11
One-Channel
Extender
Hardened
Managed
Ethernet
Ports
The Hardened Managed Ethernet Extender provides one TX port and one
Ethernet Extender port.
For the TX port, it uses RJ-45 connector and auto senses the speed of
10/100Mbps.
For the Ethernet Extender port, it uses RJ-11 and Terminal Block
connectors and auto senses the speed of 1/3/5/10/15/20/25/30/40/50Mbps.
DIP switch
There is one pin on the DIP switch for Ethernet Extender mode settings.
Refer to the table below for more details.
Loc
Rmt
The device operates in local mode The device operates in remote mode
Users Manual
12
Users Manual
13
State
Power1 Steady
Power2
Off
Power3
Ethernet
Link/ACT
FDX
Indication
Power on
Power off
Steady
Flashing
Off
Steady
Off
Ethernet Extender
Green
Amber
Green
Amber
Green
Amber
Green
Amber
Green
Amber
Remote Steady
Local
Steady
Error
Steady
Error occurred
Link
Steady
Users Manual
14
Pin
1
2
3
4
5
6
7
8
Regular Ports
Output Transmit Data +
Output Transmit Data Input Receive Data +
NC
NC
Input Receive Data NC
NC
of
Uplink ports
Input Receive Data +
Input Receive Data Output Transmit Data +
NC
NC
Output Transmit Data NC
NC
Tip
Ring
Users Manual
15
Installation
This chapter gives step-by-step installation instructions for the Hardened
Managed Ethernet Extender.
Wiring Diagram
Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75, wire
range 12-24 AWG, torque value 7 lb-in.
Users Manual
16
Fix the DIN rail attachment plate to the back panel of the Hardened
Managed Ethernet Extender.
Removal: Pull out the lower edge and then remove the Hardened
Managed Ethernet Extender from the DIN rail.
Users Manual
17
Connecting to Power
Redundant DC Terminal Block Power Inputs or 12VDC DC Jack:
12VDC DC Jack
Step 1: Connect the supplied AC to DC power adapter to the receptacle on
the topside of the Hardened Managed Ethernet Extender.
Step 2: Connect the power cord to the AC to DC power adapter and attach
the plug into a standard AC outlet with the appropriate AC voltage.
Redundant DC Terminal Block Power Inputs
There are two pairs of power inputs can be used to power up this device.
You only need to have one power input connected to run the Hardened
Managed Ethernet Extender.
Step 1: Connect the DC power cord to the plug-able terminal block on the
Hardened Managed Ethernet Extender, and then plug it into a standard DC
outlet.
Step 2: Disconnect the power cord if you want to shut down the Hardened
Managed Ethernet Extender.
DC Jack
Terminal Block
Earth Ground
DIP Switch Assignment
Loc
The device operates in local mode
Rmt
The device operates in remote mode
Users Manual
18
IP Address
In your web browser, specify the IP address of the Hardened Managed
Ethernet Extender. Default IP address is 192.168.1.10.
Password
Enter the factory default password (no password).
Or enter a user-defined password if you followed the instructions later and
changed the factory default password.
Then click on the Submit button to log on to the Hardened Managed
Ethernet Extender.
19
Basic Settings
Network Settings, Server Name Settings, NTP Server Settings
Advanced Settings
Lan Settings, VDSL Settings, SNMP Settings, Link-Fault-Pass-Through
Settings, Log Settings
System Management
Save Configuration, Change Password, Accessible List, Restore Factory
Default, Firmware Upgrade, Reset VDSL, Retrain VDSL
System Monitoring
System Log, VDSL Status
Restart
Restart System
Users Manual
20
Basic Settings
Network Settings
1.
2.
3.
4.
5.
6.
7.
Users Manual
21
Server name: Click in Server Name text box. Type a server name if it
is blank, or replace the current server name with a new one.
2. Reload: Click Reload button to reload previous settings.
3. Submit: Click Submit button to apply new settings.
Users Manual
22
Users Manual
23
Advanced Settings
Lan Settings
1.
2.
3.
4.
5.
VDSL Settings
The Ethernet Extender port of this Hardened Managed Ethernet Extender
can support asymmetric mode (default setting) or symmetric mode for
upstream and downstream transmission.
Downstream
Local mode
Upstream
Remote mode
You only need to set Fixed Rate for Local mode Hardened Managed Ethernet
Extender. You dont need to set Fixed Rate for Remote mode Hardened
Managed Ethernet Extender. Local mode Hardened Managed Ethernet
Extender will dominate Fixed Rate for this pair. When Hardened Managed
Ethernet Extender is set to Local mode, the speed LEDs will follow
downstream speed. And when Hardened Managed Ethernet Extender is set
to Remote mode, the speed LEDs will follow upstream speed.
Users Manual
24
Users Manual
25
Fixed Rate: Click Fixed Rate drop-down menu to disable fixed speed
rate or select a fixed speed rate for Ethernet Extender port from the
Fixed Rate drop-down list.
Fixed Rate: bps
Disable
50M
40M
30M
25M
20M
15M
10M
5M
Users Manual
26
SNMP Settings
1.
2.
3.
4.
5.
6.
7.
8.
Get community: Click in the Get community textbox and specify a get
community name.
Set community: Click in the Set Community textbox and specify a set
community name.
sysContact: Click in the sysContact textbox and specify a new contact
for SNMP.
sysLocation: Click in the sysLocation textbox and specify a new
location for SNMP.
sysDescr: Click in the sysDescr textbox and specify a new description
for SNMP.
IP of remote SNMP trap receiver: For each IP of remote SNMP trap
receiver, Click in the IP of remote SNMP trap receiver textbox and
specify an IP address of remote SNMP trap receiver.
Reload: Click Reload button to reload previous settings.
Submit: Click Submit button to apply new settings.
Users Manual
27
Link-Fault-Pass-Through Settings
1.
Log Settings
Users Manual
28
Users Manual
29
System Management
Save Configuration
1.
Change Password
1.
Old password: Click in Old password text box and type in the old
password.
2. New password: Click in New password text box and type in the new
password.
Users Manual
30
Accessible List
1.
2.
3.
4.
5.
Users Manual
31
Restore Password Only: Check this option to restore the factory default
password.
2. Restore factory defaults (all): Check this option to restore the Hardened
Managed Ethernet Extender to the factory default values.
3. Restore factory defaults except networking settings: Check this option
to restore the Hardened Managed Ethernet Extender to the factory
default values but keep networking settings of the Hardened Managed
Ethernet Extender.
4. Submit: Click Submit button to apply new settings.
Users Manual
32
Firmware Upgrade
1.
Filename: Click in Filename text box and type the name of the file that
you intend to upgrade it to the Hardened Managed Ethernet Extender.
2. TFTP server IP: Click in the TFTP server IP textbox and specify the IP
address of TFTP server.
3. Submit: Click Submit button to apply new settings.
Reset VDSL
1.
Users Manual
33
Retrain VDSL
1.
Submit: Click Submit button to try to get a higher link speed for
Ethernet Extender port. For example, the current link speed of Ethernet
Extender port is at 25Mbps. The user can click Submit button to let
Ethernet Extender port to try to link at 30Mbps.
System Monitoring
Users Manual
34
Reload: Click the Reload button to reload the system log of the
Hardened Managed Ethernet Extender.
2. Reset / Clear: Click Reset / Clear button to reset and clean the system
log of the Hardened Managed Ethernet Extender.
VDSL Status
1.
Reload: Click the Reload button to reload the VDSL status of the
Hardened Managed Ethernet Extender.
2. Reset / Clear: Click Reset / Clear button to reset and clean the VDSL
status of the Hardened Managed Ethernet Extender.
Restart
Users Manual
35
Restart System
1.
Users Manual
36
Users Manual
37
The basic commands in the Command Line Interface (CLI) are listed in the
following table.
Users Manual
38
System Management
Command
sys uptime
sys date
sys date s MMDDhhmmYYYY.ss
MM: Month
DD: Day
hh: Hour
mm: Minute
YYYY: Year
ss: Second
sys hostname
sys hostname hostname
sys snmp
sys snmp disp
sys snmp getcommunity
Command Description
Display system uptime.
Display system date and time.
Set system date and time.
Users Manual
39
Users Manual
accessible list.
Remove all MAC addresses from
accessible list.
Remove all IP addresses from
accessible list.
Enable index_th MAC address
from accessible list.
Enable index_th IP address from
accessible list.
Disable index_th MAC address
from accessible list.
Disable index_th IP address from
accessible list.
Reboot system.
Restore default password.
Restore factory default.
Restore factory default except
network settings.
Display NTP settings.
Set NTP ON.
Set NTP OFF.
Set IP address of NTP time server
to the device.
Set NTP time zone to the device.
Set summer-time OFF.
Set summer-time ON
weekday mode.
in
the
40
Users Manual
Command Description
Display link performance of
Ethernet Extender port.
Display
statistic
counter
of
Ethernet Extender port.
Display settings of Ethernet
Extender port.
Reset chip of Ethernet Extender
port.
Reset
counter
of
Ethernet
Extender port.
Display auto upgrade settings of
Ethernet Extender port.
Display auto upgrade settings of
Ethernet Extender port.
Set auto upgrade level for
Ethernet Extender port.
Set fixed rate level (-1 ~ 9) for
Ethernet Extender port, -1 to
represent disable.
Upgrade speed of Ethernet
Extender port.
Asymmetric mode is enabled.
Asymmetric mode is disabled.
41
Network Management
Command
net ifconfig
net ifconfig disp
net ifconfig ip IP
IP: IP address of the device
net ifconfig netmask IP
IP: netmask address for the device
net ifconfig up
net ifconfig down
net ping IP
IP: IP address
net arp
net gateway
net gateway disp
net gateway add IP
IP: gateway address
net gateway del IP
IP: gateway address
net dns
net dns disp
net dns add IP
IP: DNS address
net dns del IP
IP: DNS address
net dhcp
net dhcp disp
net dhcp on
net dhcp off
net dhcp renew
net an
net an disp
net an on
net an off
net an speed speed
speed: 10 or 100
net an duplex duplex
duplex: half or full
net disp
Users Manual
Command Description
Display network configuration.
Display network configuration.
Set IP address to the device.
Set netmask address to the
device.
Activate network interface.
Shutdown network interface.
Send ICMP ECHO_REQUEST to
network hosts.
Display ARP table.
Display gateway settings.
Display gateway settings.
Add gateway address to the
device.
Remove gateway address from
the device.
Display DNS settings.
Display DNS settings.
Add DNS address to the device.
Remove DNS address from the
device.
Display DHCP settings.
Display DHCP settings.
Set the device to get IP address
from DHCP server.
Set IP address to the device
manually.
Set the device to get new IP
address from DHCP server.
Display auto negotiation settings.
Display auto negotiation settings.
Set auto negotiation ON.
Set auto negotiation OFF.
Set LAN speed.
Set LAN duplex mode.
Display all settings.
42
NET-SNMP
Object
Name
Type
Value
Setting
modeName
serialNumber
versionHW
versionSW
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String
String
String
String
sysContact
sysDescr
sysLocation
machineName
Dhcp
Ntp
ntpServer
timezone
gmtOffset
ntpPollingInterval
ac(Access Control)
Checked
acIP0~acIP7
Checked
IP
acMAC0~acMAC7
Checked
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String
String
String
String
1 or 0
1 or 0
IP or String
String
Time Zone
-12.0~+12.0 GMT Offset
1~10080
String(R/W)
1 or 0
String(R/W)
IP format
1 or 0
IP address
String(R/W)
MAC
format(R/W)
String(R/W)
String(R/W)
1 or 0
MAC
address
String
String
String(R/W)
String(R/W)
String(R/W)
String(R/W)
String(R/W)
IP address
IP address
IP address
IP address
1 or 0
MAC
format(R/W)
IP
format(R/W)
IP
format(R/W)
IP
format(R/W)
MAC
address
Description
Model
mconf
MAC
communityGet
communitySet
serverTrap
serverTrap0
serverTrap1
serverTrap2
serverTrap3
Log
EthernetConf
MAC
IP
Netmask
Gateway
IP address
IP address
IP address
DNS
DNS0
DNS1
DNS2
Users Manual
IP
IP address
format(R/W)
IP
IP address
format(R/W)
IP
IP address
format(R/W)
43
IP
IP address
format(R/W)
AN
String(R/W)
Setspeed
String(R/W)
Setduplex
String(R/W)
Speed
String(R)
ModeStatus
String(R)
FlowControl
String(R)
Opmode
String(R)
UpgradeLevel
Integer(R/W) 0 or 1
ResetVDSL
Integer(R/W) 0 or 1
Auto
Negotiation
10
or 10 = 10M
100
100 = 100M
H = Half
H or F
F = Full
1 or 0
EthernetStatus
LAN speed
D = Duplex
H
=
Half-Duplex
Flow Control
status
VDSLConf
ResetVDSLCounter Integer(R/W) 0 or 1
C = CO
P = CPE
R = RO
Max. upgrade
level
Reset VDSL
chip
Reset VDSL
counter
VDSLStatus
Users Manual
LinkPerformance
TimeConnect
Integer(R)
SnrBand1
Integer(R)
SnrBand2
Integer(R)
ERRS
Integer(R)
FailCnt
Integer(R)
LFrLosCnt
Integer(R)
SOTO
Integer(R)
SORO
Integer(R)
BCAST
Integer(R)
RXPAUS
Integer(R)
SNR of 1st
Upstream
Band
SNR of 2st
Upstream
Band
Uncorrectable
code words
Disconnection
Counter
Loss
of
Frame
Counter
Bytes
transmitted
OK counter
Bytes
received OK
counter
Broadcast
frames
received
counter
Reception
pause
packets
counter
44
TXPAUS
Integer(R)
TXBCNT
Integer(R)
RXBCNT
Integer(R)
LFPT
String(R/W)
Transmission
pause
packets
counter
Number
of
transmitted
frames
Number
of
received
frames
LinkFaultPassThrough
Users Manual
1 or 0
45
Specifications
Applicable Standards
Fixed Ports
IEEE802.3
10Base-T,
IEEE802.3u
100Base-TX,
Ethernet over VDSL
1 x 10/100Mbps Ethernet port with RJ-45
connector
1 x Ethernet Extender port with RJ-11 and
Terminal Block connectors
Speed
10Base-T
100Base-TX
Ethernet Extender
Switching Method
Store-and-Forward
Forwarding rate
Cable
10Base-T
100Base-TX
Ethernet Extender
LED Indicators
Dimensions
Weight
Power
Operating Voltage &
Max.
Current Consumption
Power Consumption
Operating
Temperature
6W Max.
-40C ~ 75C (-40 ~ 167)
Tested for functional operation @
-40C ~ 85C (-40 ~ 185)
UL508 Industrial Control Equipment certified
Maximum Surrounding Air Temperature @ 75
(167)
Storage Temperature
Users Manual
46
5 ~ 95%, non-condensing
Safety
EMI
EMS
Environmental Test
Compliance
Users Manual
47