Anda di halaman 1dari 32

Submersible Motor Pump

Amarex KRT
60 Hz

Type Series Booklet

Legal information/Copyright
Type Series Booklet Amarex KRT

All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
edited or processed for any other purpose, nor otherwise transmitted, published or made available to
a third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft, Frankenthal 03.11.2014

Contents

Contents
Waste Water ...................................................................................................................................................... 4
Submersible Motor Pump ............................................................................................................................................... 4
Amarex KRT ............................................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data .................................................................................................................................................... 4
Designation .......................................................................................................................................................... 4
Design details ....................................................................................................................................................... 5
Materials .............................................................................................................................................................. 6
Product benefits .................................................................................................................................................. 7
Acceptance tests / guarantees ............................................................................................................................ 7
Selection information .......................................................................................................................................... 7
Overview of product features / selection tables ................................................................................................ 8
Table of fluids handled ................................................................................................................................. 8
Overview of product features ..................................................................................................................... 10
Shaft seal ...................................................................................................................................................... 13
Technical data .................................................................................................................................................... 14
Mass moments of inertia as a function of motor size ............................................................................... 19
Selection charts .................................................................................................................................................. 21
Amarex KRT 40-.../80-.../100-..., n = 3500/1750/1160 rpm, K impeller ....................................................... 21
Amarex KRT 150-.../151-.../200-..., n = 1750/1160/875 rpm, K impeller .................................................... 21
Amarex KRT 250-.../300-..., n = 1750/1160/875 rpm, K impeller ............................................................... 22
Amarex KRT 350-.../400-.../500-.../600-.../700-.../900-..., n = 1160/875/700/585 rpm, K impeller ............. 22
Amarex KRT, n = 1750/1160/875 rpm, D impeller ..................................................................................... 23
Amarex KRT, n = 1750/1160 rpm, E impeller .............................................................................................. 23
Amarex KRT, n = 3500/1750/1160 rpm, F impeller ..................................................................................... 24
Amarex KRT, n = 3500 rpm, S impeller ....................................................................................................... 24
Installation types ............................................................................................................................................... 25
General assembly drawings with list of components ...................................................................................... 26
Amarex KRT, 5.5 hp to 40.0 hp ................................................................................................................... 26
Amarex KRT, 36.0 hp to 80.0 hp ................................................................................................................. 27
Amarex KRT, 6.5 hp to 50.0 hp ................................................................................................................... 28
Amarex KRT, 47.0 hp to 640.0 hp, without cooling jacket ........................................................................ 29
Amarex KRT, 47.0 hp to 640.0 hp, with cooling jacket ............................................................................. 30

Waste Water
Submersible Motor Pump

Waste Water

Designation
Example: Amarex KRT K 150-401/80 4 UN G-S IE3

Submersible Motor Pump

Amarex KRT

Key to the designation


Code
Amarex
KRT
K

150
401
80
4
UN

Main applications
Waste water management
Service water supply systems
Disposal
Sewage treatment plants
Sludge disposal

Fluids handled
Sewage containing feces
Activated sludge
Digested sludge

Raw sludge
Fluids containing gas
Industrial waste water

Operating data
Operating properties
Characteristic
Flow rate
Head
Fluid temperature
Motor rating

1)

Q
H
t
P2

Blank

Amarex KRT

Value
Up to 45,000 US.gpm [2,800 l/s]
Up to 330 ft [100 m]
Up to 140 F [60 C]
Up to 1,140 hp [850 kW]

IE3

Description
Type series
Impeller type ( Page 5)
D
Open, diagonal single-channel impeller
E
Closed single-channel impeller
F
Free-flow impeller
K
Closed multi-channel impeller
S
Impeller with cutter
Nominal discharge nozzle diameter [mm]
Maximum nominal impeller diameter [mm]
Motor size
Number of poles
Motor version
U/UN Explosion-proof, for fluid temperatures of
up to 104 F [40 C]
W/WN Explosion-proof, for fluid temperatures of
up to 140 F [60 C]
X/XN Explosion-proof, for fluid temperatures of
up to 104 F [40 C]
Z/ZN Explosion-proof, for fluid temperatures of
up to 140 F [60 C]
Material variant
G
Standard design, gray cast iron
G1
Like G with impeller made of duplex
stainless steel
G2
Like G with impeller made of white cast
iron
GH
Like G with impeller and intermediate
casing made of white cast iron
H
Hydraulic components made of white cast
iron
C1
Wetted components made of duplex
stainless steel, mechanical seal with
elastomer bellows, screws made of A4/
A 276 type 316 Ti
C2
Wetted components made of duplex
stainless steel, mechanical seal with
covered spring, screws made of 1.4462/
A 182 F51
Type of installation ( Page 25)
S
Stationary wet installation with guide
cable or guide rail installation (without
cooling jacket)
D
Stationary dry installation, vertical
P
Transportable model in wet installation
K
Stationary wet installation with guide
cable or guide rail installation (with
cooling jacket)
H
Stationary dry installation, horizontal
Motor efficiency classification
1)
No efficiency classification
IE2,
Optional efficiency classification to
IE3
IEC 60034-30

Waste Water
Submersible Motor Pump
Mixed water

Design details
Design

Raw waste water

Fully floodable submersible motor pump

Raw sludge
Recirculated sludge

Not self-priming
Close-coupled design

K impeller

Drive

Closed multichannel impeller


(impeller type K)

Three-phase asynchronous squirrel-cage motor


Version with explosion protection to NEC 500: Explosionproof for Class I, Division 1, Groups C and D, T3, hazardous
(classified) locations.

Shaft seal

For use with the following


fluids:
Contaminated, solids-laden,
non-gaseous fluids without
stringy material

K impellers are suitable for handling the following fluids:

Two bi-directional mechanical seals in tandem


arrangement, with liquid reservoir
Pumps with reinforced bearings: with leakage chamber

Activated sludge
Landfill waste water
Industrial waste water
Industrial effluent

Impeller type
Various, application-oriented impeller types
D impeller

Mechanically treated waste water


Pre-screened waste water
Stormwater

Open, diagonal
single-vane
impeller
(D impeller)

For use with the following


fluids:
Fluids containing solid
substances and long fibers

S impeller

Closed singlechannel impeller


(impeller type E)

For use with the following


fluids:
Fluids containing solid
substances and stringy
material

S impellers are suitable for handling the following fluids:

Impeller with
cutter
(impeller type S)

E impeller

For use with the following


fluids:
Fluids containing coarse
substances and/or long fibers

Domestic waste water


Waste water
Sewage containing feces

Bearings

F impeller
Free-flow
impeller
(impeller type F)

Suitable for the following


fluids
Fluids containing solids and
stringy material as well as
fluids with entrapped air or
gas

D, E and F impellers are suitable for handling the following


fluids:
Activated sludge
Digested sludge
Heating sludge

Grease-packed bearings sealed for life


Maintenance-free

Reinforced bearings
Drive-end bearing:
Grease-packed bearings sealed for life
Maintenance-free
Pump-end bearings:
Grease-packed bearings sealed for life
Can be re-lubricated

Amarex KRT

Waste Water
Submersible Motor Pump
Materials
Overview of available materials
Part
No.

Description

Material variant
G

Pump set
101
Pump casing
135
Wear plate2)
230
Impeller3)
113/16 Intermediate housing/
3
discharge cover
433.01 Mechanical seal
(drive end)
433.02 Mechanical seal
(pump end)
210
Shaft
330
Bearing bracket
410
Elastomer seals
502
Casing wear ring4)
66-2
Cooling jacket
811
Motor housing
824
Power cable
900
Screws/bolts
Installation parts
72-1
Flanged elbow
732
Claw
894
Bracket
572
Guide cable suspension
bracket
59-24 Guide cable
892

Foot plate / feet

885

Lifting chain/rope

G1

G2

EN-GJL-250
EN-GJL-250
EN-GJL-250
1.4517
EN-GJL-250

4)
5)

EN-GJN-HB555
EN-GJN-HB555
EN-GJN-HB555

1.4517
1.4517

1.4021/1.4462/C45+N
( Page 10)
1.4517
Viton (FKM)

EN-GJL-250
Nitrile butadiene rubber NBR
EN-GJL-250
1.4571/1.0038
EN-GJL-250/1.0038

VG 434
1.4517
( Page 13)
1.4462

A45)
EN-GJL-250
EN-GJN-HB555
EN-GJL-250 or EN-GJS-400-15/EN-GJS-500-7
1.4571 to DN 200; 1.0038 + Z from size 200-500
1.4571 to DN 200; EN-GJL-250 from size 200-500
1.4401
1.0038 + Z
Lifting chain: 1.4404
Lifting rope: polyamide/polypropylene

ASTM
A 48 Class 35 B
A 536 Class 60-40-18
A 532 Class II Type B (15 % Cr-Mo)
A 890 CD4MCuN
A 276 Type 410 T
A 276 Type 316 L
A 182 F51
A 276 Type 316 Ti
A 576 Gr. 1045
NBR
FKM

For D impeller
D impeller: EN-GJL-250, with hardened edges
For E and K impellers
Equivalent to 1.4571

Amarex KRT

C2
1.4517

1.4021/C45+N ( Page 10)

Gray cast iron EN-GJL-250 (lamellar graphite cast iron):


Lamellar graphite cast iron to DIN EN 1561 is the most widely
used cast material for handling municipal sewage, waste water
and sludges as well as stormwater and surface water. It is
suitable for neutral fluids which are only slightly aggressive
and cause little wear. The pH value should be 6.5, the sand
content 0.5 g/l.

3)

C1

SiC/SiC

Description of materials

2)

Carbon/SiC

Comparison of materials
EN
EN-GJL-250
EN-GJS-400-15
EN-GJN-HB555
1.4517
1.4021
1.4401
1.4462
VG 434
1.4571
C45+N
NBR
FKM

GH

1.4517
1.4517
1.4571
1.4571
1.4401/
TEFZEL
1.4571
1.4517/
1.4462
Lifting rope: polypropylene

Duplex stainless steel (1.4517 or technically equivalent


material)
Cast steel is resistant to cavitation, has excellent strength
values and is used for high circumferential speeds. An excellent
resistance to pitting corrosion makes ferritic-austenitic stainless
steel a popular choice for pumping acidic waste water
containing large amounts of chlorine, as well as seawater and
brackish water. Thanks to its good chemical resistance, e.g. also
against waste water containing phosphorous and sulphuric
acid, this material is used in a wide range of applications in the
chemical industry and process engineering. Pumps made of
duplex stainless steel have a very long service life, even when
handling brines, chemical waste water (pH value 1 - 12), gray
water and landfill leachate.
Wear-resistant white cast iron ((EN-GJN-HB555 (XCR14) or
technically equivalent material)
This is a wear-resistant white cast iron for highly abrasive fluids
containing sand, ash or iron ore sinter. It has a Rockwell
hardness of 61.5 to 68, which is higher than that of hardened
chrome steel. The chromium-molybdenum alloy cast iron
features a notably higher wear resistance than EN-GJL-250 gray
cast iron and other cast materials.

Waste Water
Submersible Motor Pump
Product benefits
Absolutely water-tight resin-sealed cable entries prevent
any water from entering the motor even in the event of
a damaged connection cable.
Reliable operation ensured by moisture sensors signaling
any ingress of moisture into the motor
Reliable operation ensured by sensors monitoring the
motor temperature and preventing overheating
Non-clogging low-maintenance design with large free
passages reduces clogging risk and, consequently,
maintenance work.
Optimum hydraulic and energy efficiency by highefficiency motors and variable hydraulic systems
For material variants C1 and C2:
Long service life due to corrosion-resistant hydraulic
components made of stainless steel

Acceptance tests / guarantees


Functional test
Every pump undergoes functional testing to KSB standard
ZN 56535.
Operating data is guaranteed to DIN EN ISO 9906/2/2B or
Hydraulic Institute Level A/B.

Acceptance tests
Acceptance tests to ISO/DIN or a comparable standard are
available against a surcharge.
Acceptance tests to Hydraulic Institute available on
request.

Quality assurance
Quality is assured by means of an audited and certified
quality assurance system to DIN EN ISO 9001.

Selection information
The indicated heads and performance data apply to
material variant G in combination with handled fluids
with a density = 1 kg/dm3 and a kinematic viscosity
20 mm2/s.
For hydraulic acceptance tests of pumps made of different
materials the documented efficiencies must be reduced by
2 percent.

K impellers are trimmed to match the duty point. Purchase


orders must always contain the H/Q data or impeller
diameter. If the hydraulic selection program is used, the
impeller diameter is automatically computed based on the
H/Q data and added to the designation of the pump set.

Pump input power


The pump input power must be matched to the density of
the fluid handled:
P2req. = fluid [kg/dm3] x P2docu
The operating point with the largest pump input power is
decisive for the operating range of the motor. To
compensate the unavoidable tolerances of the
characteristic curves of system and pump we recommend
selecting a motor size which provides sufficient power
reserves.
Recommended minimum reserves6)
Required pump input
power

Motor power reserve

[hp]

[kW]

Mains operation

40
> 40

30
> 30

10 %
5%

With frequency
inverter
15 %
10 %

If larger power reserves are stipulated by local regulations


or are required to compensate for uncertain factors in
system calculations, these larger reserves must be
provided!
For installation types K and D (with cooling jacket) a
power reserve of 2 hp [1.5 kW] must always be added for
the cooling circuit.
The motors are designed for frequency inverter operation.
The service factor for all motors equals 1.15.

General information for operating submersible motor


pumps in waste water
In the case of waste water, too low a flow velocity in the
discharge line will lead to clogging and increased wear. A
minimum flow velocity in the vertical riser of 6.56 ft/s [2 m/s]
must be observed.
In the case of waste water, too low a circumferential
speed of the impeller will lead to clogging of the hydraulic
system (frequency inverter operation). A minimum
circumferential speed (measured at the outside diameter of
the impeller) of 49.21 ft/s [15 m/s] must be observed.

Impeller types
S, F, D and E impellers can only be supplied with the
documented impeller diameters. In the purchase order,
the impeller diameter must always be added to the
designation of the pump set.

6)

If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system
calculations, these larger reserves must be provided.

Amarex KRT

Overview of product features / selection tables

Amarex KRT

Table of fluids handled


The table below for your guidance is based on KSB's long-standing experience. The data
are standard values and are not to be considered as generally binding recommendations.
More detailed advice is available from our specialist department in Halle. Make use of our
laboratory's expertise when selecting materials.
Selection aid for materials and impeller type per fluid
Fluid handled7)

9)
10)

F, S, D, E, K
F

Gray cast iron


Gray cast iron
Gray cast iron

F, D, E, K
F, D, E, K
D, K

Gray cast iron


Gray cast iron
Gray cast iron
Gray cast iron
Gray cast iron
Gray cast iron

K
F, E
F, S, D
K, F
K, F
K, F

Gray cast iron


Gray cast iron
Gray cast iron
Gray cast iron
Gray cast iron
Gray cast iron
Gray cast iron

K
K
K
K
K
K
K

Free passage > any solids contained, possibly pre-screened


Free passage > any solids contained, possibly pre-screened
Free passage > any solids contained, possibly pre-screened
ATV9) recommends a free passage of 4 [100 mm], min. free passage of 3 [76 mm]
Up to 8 %, contact KSB for fluids with high outgassing rates
Pumpable up to a dry substance content of: 13 % (D), 8 % (F), 6 % (E), 5 % (K)
Pumpable up to a dry substance content of: 13 % (D), 8 % (F), 6 % (E), 5 % (K)
Pumpable up to a dry substance content of: 13 % (D), 5 % (K)
Solvent-free, observe the operating instructions!
Solvent-free, contact KSB to handle silicone-free fluids
Material variants G2 or GH, special mechanical seal, solids content < 5 g/l
Material variants G2 or GH, special mechanical seal, solids content < 5 g/l
pH value 6.5, material variant G1 and FPM (Viton) O-rings
-

For any fluids which are not listed in this table contact KSB.
The first impeller type listed should be given preference.
ATV = German regulatory body for waste water management
Severe hydroabrasive wear occurs if solids contents of 0.5 g/l or higher are combined with circumferential speeds exceeding 20 m/s or low flow conditions to the left of the duty
point.

Waste Water

7)
8)

Gray cast iron


Gray cast iron

Comments, further recommendations

Submersible Motor Pump

Gray water
River water
Stormwater
Waste water
Untreated municipal waste water
Waste water containing air or gas
Sludge
Raw sludge
Digested sludge
Activated sludge
Industrial waste water containing ...
Paint suspensions
Lacquer/paint/varnish suspensions
Fibers/pulp
Chips/swarf
Abrasive substances10)
Mildly acidic industrial waste water
Neutral non-corrosive waste water
Ammonium hydroxide
Ammonium hydroxide 5 % NH4OH
Urea 25 % (NH2)2-CO
Potassium hydroxide 10 % KOH
Calcium hydroxide 5 % Ca(OH)2
Sodium hydroxide 5 % NaOH
Sodium carbonate 30 % Na2CO3

Recommended material Recommended


impeller type8)
Gray cast iron
K, D, E, F
Gray cast iron
K, D, E, F
Gray cast iron
K, D, E, F

Fluid handled7)

Recommended material Recommended Comments, further recommendations


impeller type8)

Neutral, non-corrosive waste water containing ...


Aliphatic hydrocarbons, e.g. oils, petrol,
Gray cast iron
butane, methane
Aromatic hydrocarbons, e.g. benzene,
Gray cast iron
styrene
Chlorinated hydrocarbons, e.g.
Gray cast iron
tetrachloroethylene, ethylene chloride,
chloroform, methylene chloride
Highly abrasive industrial waste water causing wear (chemically neutral)12)
Water containing iron ore sinter
Wear-resistant white
cast iron

FPM (Viton) O-rings11)

FPM (Viton) O-rings11)

Sinter content < 5 g/l: material variant GH


Sinter content > 5 g/l: material variant H
Lime milk content < 15 %: material variant GH

Lime milk containing quartz and pigment


suspensions

Wear-resistant white
cast iron

Wash water containing solids

Wear-resistant white
cast iron
Wear-resistant white
cast iron
Wear-resistant white
cast iron

K, F

Seawater
Brackish water

Duplex stainless steel


Duplex stainless steel

K, F
K, F

Corrosive industrial waste water

Duplex stainless steel

K, F

Waste water containing dust or ash


Water/sand mixture

12)

Material selection based on fluid analysis

K, F

Solids content < 5 g/l: material variant GH


Solids content > 5 g/l: material variant H
Material variant C2
Material variant C1 or G1 (with 250 m two-component epoxy resin) - depending on salt
content
Material variant C1 or C2 based on fluid analysis

For any fluids which are not listed in this table contact KSB.
The first impeller type listed should be given preference.
The hydrocarbons mentioned may occur in very high concentrations due to the difference in specific weight and their low solubility. If this is the case, contact KSB.
The required material variants highly depend on the operating hours, speed and flow velocity.

Waste Water

11)

Submersible Motor Pump

Amarex KRT

7)
8)

Lime milk content > 15 %: material variant H


Material selection based on fluid analysis

Waste Water
Submersible Motor Pump
Overview of product features
Material variants G, G1, G2, GH
Feature

Motors

2-pole

5 2 25 2 37 2 55 2

4-pole

4 4.KG 4 4 29 4 35 4 65 4 35 4.N 80 4.N 95 4.N 175 4.N


5 4.KG
7 4.KG

200 4.N 350 4.N

6-pole

4 6.KG 4 6 19 6 32 6 50 6 32 6.N 60 6.N 80 6.N 165 6.N


6 6.KG

190 6.N 480 6.N

530 6.N 850 6.N

150 8.N 400 8.N

460 8.N 760 8.N

8-pole

10-pole

12-pole
Suction flange
Shaft material
Shaft

Shaft protecting
sleeve
Bearings

Voltage
Cooling

A 276 Type 420


-

15)
16)
17)
18)
19)

10

40 10.N 80 10.N 110 10.N 350 10.N 390 10.N 660 10.N
-

A 276 Type A 576 Gr. 1045


420
A 276 Type 420
Greasepacked
rolling
element
bearings
sealed for
life14)

105 12.N 300 12.N 340 12.N 560 12.N

A 276 Type 420

A 276 Type 420

A 276 Type 420

A 276 Type 420

A 276 Type 420

A 276 Type 420

Pump end: re-greasable rolling element bearings


drive end: grease-packed rolling element bearings sealed for life

Not explosion-proof
or

Explosion-proof Class I, Division 1, Groups C & D, T3

DOL, soft starter, frequency


inverter or star-delta
Air Cooled by surrounding
coolin
fluid
g
(conve
ction)

Monitoring equipment
Winding
PTC
temperature
version U, W;
installation type
S, P

13)

Grease-packed
rolling element
bearings sealed
for life

Immersion depth
Power cable
Type
Length
Cable entry
Sealing elements
Elastomer seals
Shaft seal

14)

26 8 ... 35 8 26 8.N 50 8.N 75 8.N 130 8.N

13)

Explosion protection
Version U, W
Version X, Z
Motor
Starting method

DOL, soft starter, frequency inverter


460 V15)
460 V16)
Cooled by surrounding fluid or via cooling jacket

100 ft [30 m] max.


See table "Overview of power cables"
30 ft [10 m]17)
Absolutely watertight
Nitrile butadiene rubber NBR18)
Bellows-type mechanical seal19)

Mechanical seal
with covered spring

Temperature switch (bimetal) in the winding

Drilled to ANSI B16.1 Class 125; not available for all sizes; on request
For D impeller: re-greasable rolling element bearings at the pump end, grease-packed rolling element bearings sealed for
life at the drive end
Optional: 200 V, 230 V, 380 V, 575 V
60Hz:380 V, 575 V
Optional: up to 164 ft [50 m]
Optional: Viton = fluorocarbon rubber FPM
Optional: mechanical seal with covered spring

Amarex KRT

Waste Water
Submersible Motor Pump
Feature
2-pole

Motors
-

5 2 25 2 37 2 55 2

4-pole

4 4.KG 4 4 29 4 35 4 65 4 35 4.N 80 4.N 95 4.N 175 4.N


5 4.KG
7 4.KG

200 4.N 350 4.N

6-pole

4 6.KG 4 6 19 6 32 6 50 6 32 6.N 60 6.N 80 6.N 165 6.N


6 6.KG

190 6.N 480 6.N

530 6.N 850 6.N

150 8.N 400 8.N

460 8.N 760 8.N

8-pole

10-pole

12-pole
Winding
temperature
version X, Z;
installation type
S, P
Winding
temperature;
installation type
D, H, K
Coolant
temperature;
installation type
D, K
Bearing
temperature
Leakage inside
the motor
Mechanical seal
leakage

PTC

26 8 ... 35 8 26 8.N 50 8.N 75 8.N 130 8.N


-

40 10.N 80 10.N 110 10.N 350 10.N 390 10.N 660 10.N

105 12.N 300 12.N 340 12.N 560 12.N


Temperature switch (bimetal) in the winding, plus PTC for explosion protection
-

PTC

PTC

-20)

PTC

PT100 at the pump


and drive end

PT100 at the pump end21)


Leakage sensor in the motor space

Float
switch in
the leakage
area for D
impeller
-

Float switch in leakage area

Vibration sensor
-22)
Coating
Environmentally friendly KSB standard coating, color RAL 500223)
Maximum fluid and ambient temperature
Version U
104 F [40 C]
Version X
104 F [40 C]
Version W, Z
140 F [60 C]
Tests/inspections
Hydraulic system
KSB standard (ZN 56525)24)
General
KSB standard (ZN 56525)
Type of installation
Stationary, with
Installation depth 15 ft [4.5 m]25)
guide cable
arrangement
Stationary, with
Installation depth 15 ft [4.5 m]26)
guide rail
arrangement
Transportable
Up to size 300-401, except sizes 200-500/501, 200-631, 250-630
27)
Stationary, dry
With cooling jacket

20)
21)
22)
23)
24)
25)
26)
27)

Optional: PT100 at the pump end


Optional: PT100 at the drive end
Optional: internal vibration sensor
Optional: 250 m two-component epoxy coating
Optional: S, D, E, F impellers to ISO 9906/A, K impellers to ISO 9906//1/2/A
Optional: up to 98 ft [30 m], from size 200-500 up to 49 ft [15 m]
Optional: up to 98 ft [30 m]
With convection cooling

Amarex KRT

11

Waste Water
Submersible Motor Pump
Material variants H, C1, C2
Feature

Motors

2-pole

5 2 25 2

4-pole

4 4 29 4

35 4 65 4

80 4.N

95 4.N 175 4.N

200 4.N ... 350 4.N

6-pole

4 6 19 6

32 6 50 6

60 6.N

80 6.N 165 6.N

190 6.N ... 480 6.N

8-pole

26 8 35 8

50 8.N

75 8.N 130 8.N

150 8.N ... 480 8.N

10-pole

110 10.N ... 350 10.N

12-pole
105 12.N ... 300 12.N
28)
Suction flange
Shaft material for material variant H
Shaft
A 276 Type 420
A 576 Gr. 1045
A 276 Type 420
Shaft protecting sleeve
A 276 Type 420
A 276 Type 420
Shaft material for material variant C1, C2
Shaft
A 182 F51 / A 576 Gr. 1045
A 276 Type 420
Shaft protecting sleeve
A 182 F51
A 182 F51
A 182 F51
Bearings
Grease-packed rolling
Pump end: re-greasable rolling element bearings
element bearings sealed for drive end: grease-packed rolling element bearings sealed for
life
life
Explosion protection
Version U, W
Not explosion-proof
Version X, Z
or
Explosion-proof Class I, Division 1, Groups C & D, T3
Motor
Starting method
Voltage
Cooling
Immersion depth
Power cable
Type
Length
Cable entry
Sealing elements
Elastomer seals
Shaft seal
Monitoring equipment
Winding temperature, version U, W
Winding temperature, version X, Z
Bearing temperature
Leakage inside the motor
Mechanical seal leakage

Vibration sensor
Coating

DOL, soft starter, frequency inverter or star-delta


460 V29)
Cooled by surrounding fluid
100 ft [30 m] max.
See table "Overview of power cables"
30 ft [10 m]30)
Absolutely watertight
Nitrile butadiene rubber NBR31), for C2 generally fluorocarbon rubber FPM
Mechanical seal with
C1: bellows-type mechanical seal32)
covered spring
H, C2: mechanical seal with covered spring
Temperature switch (bimetal) in the winding
Temperature switch (bimetal) in the winding, plus PTC for explosion protection
-33)
PT100 at the pump end34)
Leakage sensor in the motor space
Float switch in
Float switch in leakage area
the leakage area
for D impeller
-35)
Material variant H: environmentally friendly KSB standard coating, primer dry film
thickness 1 1/2 - 2 mils (35-50 m), top coat: two-component epoxy coating dry film
thickness 6 mils (150 mm), color RAL 500236)
Material variants C1, C2: without coating

Maximum fluid and ambient temperature


Version U, X
Version W, Z
Tests/inspections
Hydraulic system

28)
29)
30)
31)
32)
33)
34)
35)
36)

12

104 F [40 C]
140 F [60 C]
KSB standard (ZN 56525)37)

Drilled to ANSI B16.1 Class 125; not available for all sizes; on request
Optional: 200 V, 230 V, 380 V, 575 V
Optional: up to 164 ft [50 m]
Optional: Viton = fluorocarbon rubber FPM
Optional: mechanical seal with covered spring
Optional: PT100 at the pump end
Optional: PT100 at the drive end
Optional: internal vibration sensor
Optional: dry film thickness 12 mils (300 m)

Amarex KRT

Waste Water
Submersible Motor Pump
Feature

Motors

2-pole

5 2 25 2

4-pole

4 4 29 4

35 4 65 4

80 4.N

95 4.N 175 4.N

200 4.N ... 350 4.N

6-pole

4 6 19 6

32 6 50 6

60 6.N

80 6.N 165 6.N

190 6.N ... 480 6.N

8-pole

26 8 35 8

50 8.N

75 8.N 130 8.N

150 8.N ... 480 8.N

10-pole

110 10.N ... 350 10.N

12-pole
General
Type of installation
Stationary, with guide cable
arrangement
Transportable

KSB standard (ZN 56525)

105 12.N ... 300 12.N

Installation depth 15 ft [4.5 m]38)


Installation depth 15 ft [4.5 m]39)

Overview of power cables


Feature
Design
Rated voltage
EMC screening
Insulation material
Max. continuous temperature of insulation
For permanent immersion in waste water to DIN
VDE 0282-16/HD22.16

S1BN8-F
rubber-sheathed cable
Standard
1000 V
EPR40)
194 F [90 C]

S07RC4N8-F
rubber-sheathed cable
Optional
750 V

EPR40)
194 F [90 C]

TEHSITE
Tefzel cable
Optional
750 V
ETFE41)
275 F [135 C]

Shaft seal
Available shaft seal types per bearing bracket
Standard design
Mechanical seal with elastomer bellows (NBR, optional

37)
38)
39)
40)
41)
42)
43)
44)
45)

Standard variant42)
Viton)43)

Product-side mechanical seal with covered spring44)45)

Optional: S, D, E, F impellers to Hydraulic Institute, Level B; K impellers to Hydraulic Institute, Level A


Optional: up to 98 ft [30 m], from size 200-500 up to 49 ft [15 m]
Up to size 300-401, except for sizes 200-501, 200-631, 250-630
EPR = ethylene propylene rubber
ETFE = ethylene tetrafluoroethylene
A surcharge and longer delivery times apply to standard variants.
For all types of waste water
For very abrasive fluids or fluids containing metallic particles (e.g. shavings from drilling)
Standard for material variants H and C2 (optional for material variants G, G1, G2, GH and C1)

Amarex KRT

13

Waste Water
Submersible Motor Pump
Technical data

S 40-250
F 40-250
F 80-250
F 80-251
F 100-250
F 100-316
F 100-401
F 150-315
F 150-401
E 80-251
E 100-251
E 150-315
E 150-401
E 200-401
D 80-315
D 100-251
D 100-315
D 100-316
D 150-251
D 150-315
D 150-400
D 150-401
D 200-315
D 200-400
D 250-400
D 300-400
K 40-250
K 80-251
K 100-251
K 100-316
K 100-400
K 100-401
K 150-315
K 150-400
K 150-401
K 151-401
K 200-315
K 200-316
K 200-330
K 200-400
K 200-401

46)
47)

14

G
G, G1, G2, GH
G, G1, G2, GH
G
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G
G
G
G
G
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1
G, G1, GH
G, G1, GH
G
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1
G, G1, GH

4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
2
2
2
2
2
3
2
3
3
2
3
3
3

[]
9
/32
1
3
4
4
4
4
4 3/4
5 5/16
3
3 1/8 - 3 3/4
4 1/2 - 4 3/4
4 1/2- 5 1/2
4 3/4 - 5 1/2
2 1/2
3
3
3 3/8
4
4
4
4 3/8
4
4
4 3/4
6
5
/8
1 1/8
3
3
3
2
3
3
3
3 1/8
2 3/4
4
2 3/4
3
3 1/8

[]
9 1/4
8 1/4
10 7/16
9 1/16
10 7/16
11 7/16
15 3/8
11 7/16
15 3/8
10 5/8
9 15/16
12 5/8
16
15 3/4
10 1/4
10 7/16
8 3/4
12 1/16
10
12 1/2
14 15/16
15 1/8
12 3/8
14 3/4
14 9/16
16 1/16
10 1/4
8 11/16
9 13/16
11 5/8
16 1/16
15 7/8
12 3/16
15 7/8
15 7/8
16 1/16
11 5/8
12
12 13/16
16 1/16
15 7/8

[]
6 7/8
5 7/8
5 7/8
5 11/16
7 7/8
9 5/16
12 13/16
9 13/16
10 5/8
8 7/8
7 1/4
10
13 11/16
12 9/16
9 1/16
9 3/16
7 11/16
10 5/8
8 7/8
11
12 13/16
14 9/16
11
14
12 9/16
14 3/4
5 7/8
5 1/2
6 7/8
9 1/4
14
12 3/16
9 1/4
11 13/16
12 3/16
11 13/16
9 5/8
10 7/16
11 5/16
11 13/16
13

[psi]
87,0
87,0
145,0
87,0
145,0
87,0
87,0
87,0
145,0
145,0
145,0
87,0
87,0
87,0
87,0
87,0
145,0
87,0
145,0
145,0
87,0
87,0
145,0
145,0

Data applies to maximum impeller diameter and impeller with water fill
Permissible operating pressure = inlet pressure + pressure at Q = 0

Amarex KRT

[psi]
130,5
130,5
217,5
130,5
217,5
130,5
130,5
130,5
217,5
217,5
217,5
130,5
130,5
130,5
130,5
130,5
217,5
130,5
217,5
217,5
130,5
130,5
217,5
217,5

[psi]
145,0
110,0
91,4
90,0
49,3
71,1
110,2
26,1
61,0
59,5
49,3
45,0
91,4
82,7
150,8
50,8
98,6
52,2
27,5
47,9
75,4
76,9
39,2
60,9
50,8
24,7
145,0
95,7
52,2
71,1
133,4
134,9
50,8
130,5
129,1
124,7
27,6
24,7
75,4
98,6
103,0

Max. test pressure

Max. operating pressure47)

Max. test pressure

Min. impeller diameter

Max. operating pressure47)

Dry installation
Wet installation
(installation types D, H) (installation types S, P,
K)
Max. impeller diameter

Free passage

Number of impeller channels

Impeller

Material variant

Pump size

[psi]
188,6
142,1
118,9
117,5
65,2
92,8
142,1
33,4
79,8
78,3
65,3
59,5
118,9
107,3
197,3
66,7
127,6
68,2
34,8
62,4
98,6
100,1
49,3
79,8
66,7
31,9
188,5
124,7
68,2
92,8
174,1
175,5
66,7
169,6
168,2
162,4
34,8
31,9
100,1
127,6
133,4

Mass moment of inertia J46)

Gray cast iron (G, G1, G2, GH)

[kgm2]
0,03
0,03
0,14
0,057
0,056
0,075
0,248
0,144
0,248
0,17
0,18
0,31
0,68
0,86
0,124
0,115
0,065
0,233
0,115
0,289
0,573
0,999
0,261
0,825
0,653
0,925
0,047
0,15
0,07
0,13
1,1
0,504
0,18
0,83
0,916
0,52
0,22
0,22
0,35
0,52
0,52

Waste Water

K 200-501
K 200-631
K 250-400
K 250-401
K 250-630
K 250-900
K 300-400
K 300-401
K 300-420
K 300-500
K 300-503
K 350-420
K 350-500
K 350-501
K 350-630
K 350-636
K 350-710
K 400-500
K 400-630
K 400-710
K 400-900
K 500-630
K 500-710
K 500-900
K 600-520
K 600-710
K 700-900
K 700-901

46)
47)

G, G1
G, G1
G, G1, GH
G, G1, GH
G, G1
G, G1
G, G1
G, G1, GH
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1

2
2
3
2
4
3
3
2
3
3
5
3
3
2
3
5
3
3
3
3
3
3
3
3
3
3
3
3

[]
4 1/8
4 1/8
3 3/8
4 1/8
3 1/2
4 5/16
4
5 5/16
4
3 1/2
2
4
4 5/16
6 5/8
5 5/16
3
4 1/4
5 1/8
5 1/4
6 1/2
5 1/8
5 1/4
6
7 15/16
5 11/16
6 1/2
7 1/2
7 1/16

[]
19 3/4
24 1/2
14 9/16
15 3/4
24 13/16
22 1/16
16 1/16
16 1/16
16 1/16
19 13/16
18 7/8
17 11/16
20
20 1/16
24 13/16
23 7/16
28 3/4
20
24 7/16
29 1/8
32 11/16
22 15/16
29 1/8
35 3/4
20 15/16
29
33 7/16
35 3/4

[]
17 11/16
21 1/4
11 13/16
12 3/16
19 11/16
28 1/4
13 1/16
14 7/16
14 9/16
16 15/16
15 15/16
15 1/4
16 3/4
19 1/2
19 11/16
20 1/16
22 13/16
17 7/16
21 1/2
23 1/8
25 15/16
20 7/16
23 1/8
28 3/8
18
26 15/16
29 1/16
29 15/16

[psi]
145,0
145,0
145,0
145,0
145,0
232,0
145,0
145,0
87,0
145,0
145,0
87,0
87,0
87,0
145,0
145,0
145,0
87,0
87,0
145,0
232,0
58,0
916
145,0
58,0
58,0
43,5
130,5

[psi]
217,5
217,5
217,5
217,5
217,5
348,0
217,5
217,5
130,5
217,5
217,5
130,5
130,5
130,5
217,5
217,5
217,5
130,5
130,5
217,5
348,0
87,0
174,1
217,5
87,0
87,0
65,0
195,8

[psi]
92,8
142,1
95,7
87,0
150,8
169,7
50,8
33,4
50,8
90,0
129,1
50,8
82,7
40,6
105,9
92,8
136,3
49,3
89,9
127,6
163,9
60,9
100,1
116,0
34,8
60,9
47,9
104,4

Max. test pressure

Max. operating pressure47)

Max. test pressure

Min. impeller diameter

Max. operating pressure47)

Dry installation
Wet installation
(installation types D, H) (installation types S, P,
K)
Max. impeller diameter

Free passage

Number of impeller channels

Impeller

Material variant

Pump size

[psi]
120,4
185,6
123,3
113,1
195,8
220,5
66,7
42,1
105,9
116,0
168,2
66,7
107,3
53,6
136,3
120,4
176,9
65,2
116,0
166,8
213,2
79,8
130,5
149,4
46,4
79,8
62,4
134,9

Mass moment of inertia J46)

Submersible Motor Pump

[kgm2]
1,68
4,41
0,5
0,55
2,76
19,03
0,75
0,75
0,95
1,48
2,5
1,22
3,12
3
5,22
5,42
10,6
3,37
8,21
14
17,79
6,11
13,0
45
7,02
16,96
40
50

Data applies to maximum impeller diameter and impeller with water fill
Permissible operating pressure = inlet pressure + pressure at Q = 0

Amarex KRT

15

Waste Water
Submersible Motor Pump

S 40-250
F 40-250
F 80-250
F 80-251
F 100-250
F 100-316
F 100-401
F 150-315
F 150-401
E 80-251
E 100-251
E 150-315
E 150-401
E 200-401
D 80-315
D 100-251
D 100-315
D 100-316
D 150-251
D 150-315
D 150-400
D 150-401
D 200-315
D 200-400
D 250-400
D 300-400
K 40-250
K 80-251
K 100-251
K 100-316
K 100-400
K 100-401
K 150-315
K 150-400
K 150-401
K 151-401
K 200-315
K 200-316
K 200-330
K 200-400
K 200-401
K 200-501
K 200-631
K 250-400
K 250-401
K 250-630
K 250-900
K 300-400

48)

16

G
G, G1, G2, GH
G, G1, G2, GH
G
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G, G1, G2, GH
G
G
G
G
G
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1
G, G1, GH
G, G1, GH
G
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1, GH
G, G1
G, G1, GH
G, G1
G, G1
G, G1, GH
G, G1, GH
G, G1
G, G1
G, G1

4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
2
2
2
2
2
2
3
2
3
3
2
3
3
3
2
2
3
2
4
3
3

[mm]
7
25
76
50
100
100
100
120
135
76
80-95
110-120
115-140
121-143
65
76
75
85
100
100
100
110
100
100
120
150
15
33
76
76
76
50
76
76
76
80
70
100
70
76
80
105
105
85
105
90
110
100

[mm]
235
210
265
230
265
290
390
290
390
270
252
320
407
400
260
265
222
306
254
317
363
384
315
375
370
408
260
220
250
295
408
404
310
404
404
408
295
305
326
408
404
502
622
370
400
630
840
408

[mm]
175
150
150
145
200
236
325
250
270
225
184
254
348
319
230
234
196
270
225
280
326
370
280
355
320
375
150
140
175
235
355
310
235
300
310
300
245
265
287
300
330
450
540
300
310
500
717
332

[bar]
6
6
10
6
10
6
6
6
10
10
10
6
6
6
6
6
10
6
10
10
6
6
10
10
10
10
10
10
10
16
10

Data applies to maximum impeller diameter and impeller with water fill

Amarex KRT

[bar]
9
9
15
9
15
9
9
9
15
15
15
9
9
9
9
9
15
9
15
15
9
9
15
15
15
15
15
15
15
24
15

[bar]
10
7,6
6,3
6,2
3,4
4,9
7,6
1,8
4,2
4,1
3,4
3,1
6,3
5,7
10,4
3,5
6,8
3,6
1,9
3,3
5,2
5,3
2,7
4,2
3,5
1,7
10
6,6
3,6
4,9
9,2
9,3
3,5
9,0
8,9
8,6
1,9
1,7
5,2
6,8
7,1
6,4
9,8
6,6
6
10,4
11,7
3,5

Max. test pressure

Max. operating pressure47)

Max. test pressure

Min. impeller diameter

Max. operating pressure47)

Dry installation
Wet installation
(installation types D, H) (installation types S, P,
K)
Max. impeller diameter

Free passage

Number of impeller channels

Impeller

Material variant

Pump size

[bar]
13
9,8
8,2
8,1
4,5
6,4
9,8
2,3
5,5
5,4
4,5
4,1
8,2
7,4
13,6
4,6
8,8
4,7
2,4
4,3
6,8
6,9
3,4
5,5
4,6
2,2
13
8,6
4,7
6,4
12
12,1
4,6
11,7
11,6
11,2
2,4
2,2
6,8
8,8
9,2
8,3
12,8
8,5
7,8
13,5
15,2
4,6

Mass moment of inertia J48)

Gray cast iron (G, G1, G2, GH)

[kgm2]
0,03
0,03
0,14
0,057
0,056
0,075
0,248
0,144
0,248
0,17
0,18
0,31
0,68
0,86
0,124
0,115
0,065
0,233
0,115
0,289
0,573
0,999
0,261
0,825
0,653
0,925
0,047
0,15
0,07
0,13
1,1
0,504
0,18
0,83
0,916
0,52
0,22
0,22
0,35
0,52
0,52
1,68
4,41
0,5
0,55
2,76
19,03
0,75

Waste Water
Submersible Motor Pump

K 300-401
K 300-420
K 300-500
K 300-503
K 350-420
K 350-500
K 350-501
K 350-630
K 350-636
K 350-710
K 400-500
K 400-630
K 400-710
K 400-900
K 500-630
K 500-710
K 500-900
K 600-520
K 600-710
K 700-900
K 700-901

G, G1, GH
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1
G, G1

2
3
3
5
3
3
2
3
5
3
3
3
3
3
3
3
3
3
3
3
3

[mm]
135
100
90
50
100
110
170
135
75
110
130
132
165
130
133
150
202
145
165
190
180

[mm]
408
408
504
480
450
508
509
630
595
730
508
620
739
830
582
739
908
532
736
850
908

[bar]
10
6
10
10
6
6
6
10
10
10
6
6
10
16
4
8
10
4
4
3
9

[bar]
15
9
15
15
9
9
9
15
15
15
9
9
15
24
6
12
15
6
6
4,5
13,5

[bar]
2,3
5,6
6,2
8,9
3,5
5,7
2,8
7,3
6,4
9,4
3,4
6,2
8,8
11,3
4,2
6,9
8
2,4
4,2
3,3
7,2

Mass moment of inertia J48)

Max. test pressure

Max. test pressure

Min. impeller diameter


[mm]
367
370
430
405
387
426
495
500
510
580
443
546
587
659
520
586
721
457
685
738
760

Max. operating pressure47)

Dry installation
Wet installation
(installation types D, H) (installation types S, P,
K)
Max. impeller diameter

Free passage

Number of impeller channels

Material variant

Impeller

Max. operating pressure47)

Pump size

[bar]
2,9
7,3
8
11,6
4,6
7,4
3,7
9,4
8,3
12,2
4,5
8
11,5
14,7
5,5
9,0
10,3
3,2
5,5
4,3
9,3

[kgm2]
0,75
0,95
1,48
2,5
1,22
3,12
3
5,22
5,42
10,6
3,37
8,21
14
17,79
6,11
13,0
45
7,02
16,96
40
50

Industrial materials (H, C1, C2)

S 50-210
F 40-250
F 100-250
F 100-316
F 100-401
F 150-315
F 150-401
K 40-250
K 80-251
K 100-251
K 100-316
K 100-400

48)

C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
C1, C2

4
3
2
2
2
3

[]
/32
1
4
4
4
4 3/4
5 5/16
5
/8
1 1/8
3
3
3
9

[]
7 1/4
8 1/4
10 7/16
11 7/16
15 3/8
11 7/16
15 3/8
10 1/4
8 11/16
9 13/16
11 5/8
16 1/16

[]
6 7/8
5 7/8
7 7/8
9 5/16
12 13/16
9 13/16
10 5/8
5 7/8
5 1/2
6 7/8
9 1/4
14

Max. operating pressure47)

Max. test pressure

[psi]
60,9
114,6
49,3
71,1
110,2
26,1
60,9
145,0
95,0
52,2
71,1
137,8

[psi]
79,8
142,1
65,3
92,8
142,1
33,4
79,8
188,6
124,7
68,2
92,8
179,9

Mass moment of inertia J46)

Wet installation
(installation type S, P)
Min. impeller diameter

Max. impeller diameter

Free passage

Number of impeller channels

Impeller

Material variant

Pump size

[kgm2]
0,006
0,03
0,056
0,075
0,248
0,144
0,248
0,047
0,15
0,07
0,13
1,1

Data applies to maximum impeller diameter and impeller with water fill

Amarex KRT

17

Waste Water

Submersible Motor Pump

H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
C1, C2
C1, C2
H, C1, C2
H, C1, C2
C1, C2
H, C1, C2
H, C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2

2
2
2
3
3
2
3
3
2
2
3
2
3
3
2
3
3
5
3
3
3
5
3
3
3
3
3
3
3
3

[]
2
3
3
3 1/8
2 3/4
4
2 3/4
3 1/8
4 1/8
4 1/8
3 3/8
4 1/8
3 9/16
4
5 5/16
4
3 9/16
2
4
4 5/16
5 5/16
3
4 5/16
5 1/8
5 1/4
5 1/4
5 3/4
6 1/2
7 1/2
7 1/16

[]
[]
15 7/8
12 3/16
12 3/16
9 1/4
7
15 /8
12 3/16
7
15 /8 11 13/16
11 5/8
9 5/8
12
10 7/16
12 13/16 11 5/16
15 7/8
13
19 3/4 17 11/16
24 1/2
21 1/4
9
14 /16 11 13/16
15 3/4
12 3/16
13
24 /16 19 11/16
16 1/16 13 1/16
16 1/16
14 7/16
16 1/16 14 9/16
19 13/16 16 15/16
18 7/8
15 15/16
17 11/16 15 1/4
20
16 3/4
13
24 /16 19 11/16
23 7/16 20 1/16
28 3/4 22 13/16
20
17 7/16
24 7/16
21 1/2
22 15/16 20 7/8
20 15/16
18
29
26 15/16
33 7/16
29 1/16
3
35 /4 29 15/16

Max. operating pressure47)

Max. test pressure

[psi]
134,9
50,8
129,1
124,7
27,6
24,7
75,4
103,0
92,8
142,1
95,7
87,0
150,8
50,8
33,4
81,2
90,0
129,1
50,8
82,7
105,9
92,8
136,3
49,3
90,0
60,9
34,8
60,9
47,9
104,4

[psi]
175,5
66,7
168,2
162,4
34,8
31,9
98,6
98,6
120,4
185,6
123,3
113,1
195,8
66,7
42,1
105,9
116,0
168,2
66,7
107,3
136,3
120,4
177,0
65,3
116,0
79,8
46,4
79,8
62,4
134,9

Mass moment of inertia J46)

Wet installation
(installation type S, P)
Min. impeller diameter

Free passage

Number of impeller channels

Material variant
K 100-401
K 150-315
K 150-401
K 151-401
K 200-315
K 200-316
K 200-330
K 200-401
K 200-501
K 200-631
K 250-400
K 250-401
K 250-630
K 300-400
K 300-401
K 300-420
K 300-500
K 300-503
K 350-420
K 350-500
K 350-630
K 350-636
K 350-710
K 400-500
K 400-630
K 500-630
K 600-520
K 600-710
K 700-900
K 700-901

Max. impeller diameter

Impeller

Pump size

[kgm2]
0,504
0,18
0,916
0,52
0,22
0,22
0,35
0,52
1,68
4,41
0,5
0,55
2,76
0,75
0,75
0,95
1,48
2,5
1,22
3,12
5,22
5,42
10,6
3,37
8,21
6,11
7,02
16,96
40
50

S 50-210
F 40-250
F 100-250
F 100-316
F 100-401
F 150-315
F 150-401

18

C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2

Amarex KRT

4
-

[mm]
7
25
100
100
100
120
135

[mm]
185
210
265
290
390
290
390

[mm]
170
150
200
236
325
250
270

Max. operating pressure47)

Max. test pressure

[bar]
4,2
7,6
3,4
4,9
7,6
1,8
4,2

[bar]
5,5
9,8
4,5
6,4
9,8
2,3
5,5

Mass moment of inertia J46)

Wet installation (installation types S, P)


Min. impeller diameter

Max. impeller diameter

Impeller

Free passage

Material variant

Pump size

Number of impeller channels

Industrial materials (H, C1, C2)

[kgm2]
0,006
0,03
0,056
0,075
0,248
0,144
0,248

Waste Water

K 40-250
K 80-251
K 100-251
K 100-316
K 100-400
K 100-401
K 150-315
K 150-401
K 151-401
K 200-315
K 200-316
K 200-330
K 200-401
K 200-501
K 200-631
K 250-400
K 250-401
K 250-630
K 300-400
K 300-401
K 300-420
K 300-500
K 300-503
K 350-420
K 350-500
K 350-630
K 350-636
K 350-710
K 400-500
K 400-630
K 500-630
K 600-520
K 600-710
K 700-900
K 700-901

H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
H, C1, C2
C1, C2
C1, C2
H, C1, C2
H, C1, C2
C1, C2
H, C1, C2
H, C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2
C1, C2

3
2
2
2
3
2
2
2
3
3
2
3
3
2
2
3
2
3
3
2
3
3
5
3
3
3
5
3
3
3
3
3
3
3
3

[mm]
15
33
76
76
76
50
76
76
80
70
100
70
80
105
105
85
105
90
100
135
100
90
50
100
110
135
75
110
130
132
133
145
165
190
180

[mm]
260
220
250
295
408
404
310
404
404
295
305
326
404
502
622
370
400
630
408
408
408
504
480
450
508
630
595
730
508
620
582
532
736
850
908

Max. operating pressure47)

Max. test pressure

[bar]
10
6,6
3,6
4,9
9,5
9,3
3,5
8,9
8,6
1,9
1,7
5,2
7,1
6,4
9,8
6,6
6
10,4
3,5
2,3
5,6
6,2
8,9
3,5
5,7
7,3
6,4
9,4
3,4
6,2
4,2
2,4
4,2
3,3
7,2

[bar]
13
8,6
4,7
6,4
12,4
12,1
4,6
11,6
11,2
2,4
2,2
6,8
9,2
8,3
12,8
8,5
7,8
13,5
4,6
2,9
7,3
8
11,6
4,6
7,4
9,4
8,3
12,2
4,5
8
5,5
3,2
5,5
4,3
9,3

[mm]
150
140
175
235
355
310
235
310
300
245
265
287
330
450
540
300
310
500
332
367
370
430
405
387
426
500
510
580
443
546
520
457
685
738
760

Mass moments of inertia as a function of motor size

4-pole

2-pole

Motor

Motor
52
62
82
12 2
17 2
22 2 / 25 2
23 2
37 2
55 2

Mass moment of inertia J


[kgm2]
0,01
0,01
0,01
0,02
0,03
0,04
0,05
0,13
0,14

44/54
74
11 4
16 4
4 4.KG / 5 4.KG
7 4.KG
19 4 / 21 4
23 4
29 4
35 4
50 4
65 4
35 4.N
50 4.N

Mass moment of inertia J46)

Wet installation (installation types S, P)


Min. impeller diameter

Max. impeller diameter

Impeller

Free passage

Material variant

Pump size

Number of impeller channels

Submersible Motor Pump

[kgm2]
0,047
0,15
0,07
0,13
1,1
0,504
0,18
0,916
0,52
0,22
0,22
0,35
0,52
1,68
4,41
0,5
0,55
2,76
0,75
0,75
0,95
1,48
2,5
1,22
3,12
5,22
5,42
10,6
3,37
8,21
6,11
7,02
16,96
40
50

Mass moment of inertia J


[kgm2]
0,01
0,02
0,04
0,05
0,05
0,06
0,06
0,07
0,11
0,22
0,25
0,30
0,25
0,28

Amarex KRT

19

Waste Water
Submersible Motor Pump
Motor

Mass moment of inertia J

65 4.N
80 4.N
95 4.N
110 4.N
130 4.N
155 4.N
175 4.N
200 4.N
250 4.N
300 4.N
350 4.N

[kgm2]
0,33
0,46
0,55
0,63
1,26
1,43
1,57
3,78
4,13
4,82
5,51

6-pole
Motor

Mass moment of inertia J

46
66
96
12 6
4 6.KG
6 6.KG
15 6
19 6
20 6
26 6
32 6
40 6
50 6
32 6.N
40 6.N
50 6.N
60 6.N
80 6.N
100 6.N
120 6.N
140 6.N
165 6.N
190 6.N
225 6.N
260 6.N
320 6.N
360 6.N
400 6.N
440 6.N
480 6.N
530 6.N
580 6.N
630 6.N
690 6.N
770 6.N
850 6.N

[kgm2]
0,02
0,02
0,05
0,07
0,07
0,09
0,09
0,09
0,10
0,13
0,34
0,42
0,51
0,37
0,45
0,54
0,66
0,80
0,94
1,89
2,25
2,55
7,30
8,57
9,84
14,3
15,9
17,6
19,2
20,7
31,5
36,3
41,1
45,8
50,6
55,3

8-pole
Mass moment of inertia J

Motor

[kgm2]
0,09
0,12
0,18
0,37

10 8
17 8
21 8
26 8

20

Amarex KRT

Motor

Mass moment of inertia J

35 8
26 8.N
35 8.N
50 8.N
75 8.N
90 8.N
110 8.N
130 8.N
150 8.N
185 8.N
220 8.N
260 8.N
300 8.N
350 8.N
400 8.N
460 8.N
530 8.N
580 8.N
630 8.N
690 8.N
760 8.N

[kgm2]
0,47
0,40
0,50
0,66
0,94
1,98
2,25
2,55
7,30
8,57
9,84
13,3
15,9
19,1
20,7
31,5
36,3
41,1
45,8
50,6
55,3

10-pole
Motor
40 10.N
60 10.N
75 10.N
90 10.N
110 10.N
150 10.N
190 10.N
230 10.N
270 10.N
310 10.N
350 10.N
390 10.N
430 10.N
475 10.N
535 10.N
600 10.N
660 10.N

Mass moment of inertia J


[kgm2]
1,75
1,93
2,20
2,49
7,96
9,66
11,8
17,7
20,5
23,2
25,8
36,1
41,6
47,2
52,7
58,2
63,7

12-pole
Motor
105 12.N
135 12.N
165 12.N
195 12.N
230 12.N
265 12.N
290 12.N
300 12.N
340 12.N
380 12.N
450 12.N
490 12.N
560 12.N

Mass moment of inertia J


[kgm2]
7,96
9,66
11,8
17,7
20,5
23,2
36,1
25,8
41,6
47,2
52,7
58,2
63,7

Waste Water
Submersible Motor Pump
Selection charts
Amarex KRT 40-.../80-.../100-..., n = 3500/1750/1160 rpm, K impeller
0.3

0.4 0.5

m/h

l/s

0.2

0.1

300

0.3

0.4 0.5

10

20

30

40

50

10

100
20

200

30

200

40

300

50

400
100

100-400K/4p
100-401K/4p

40-250K/2p

50
40

100

30

80-251K/2p
100-316K/4p

20

40-250K/4p

50
40

100-251K/6p

10

30
m
20
5

H
[ft]

10
1 Q[US.gpm] 2
1

IM.gpm

3
2

4
3

5
4

10

20

10

30
20

40
30

50
40

100
50

200
100

300
200

400 500
300

1000

400 500

2000

1000

Amarex KRT 150-.../151-.../200-..., n = 1750/1160/875 rpm, K impeller


m/h

50

100

20

300

200
30

40

300
l/s

50

400

500

1000

100

200

200

300

400

151-401K/4p
150-400K/4p

50

200-631K

40
100

30
150-401K/4p
150-401K/6p

200-400K/4p
200-330K/4p

150-400K/6p

20

50
200-400K/6p

40
150-315K/6p

30

10

200-330K/6p

20
5
200-315K/6p

10

H
[ft]

200-316K/6p
5

4
1

2
200

300
200

400
300

500
400

Q[US.gpm]
500

IM.gpm

1000

2000
1000

3000
2000

4000
3000

5000
4000

7000
5000

Amarex KRT

21

Waste Water
Submersible Motor Pump
Amarex KRT 250-.../300-..., n = 1750/1160/875 rpm, K impeller
200

300

50

400

400

l/s

m/h

500

100

1000

200

2000

300

400

3000

500

4000
1000
100

300

250-630K/6p

200

250-900K/8p
50

250-630K/8p

40
300-503K
100

30
300-500K/6p
20
250-400K/6p

50

300-420K/6p

250-400K/4p

40
10

30

20

300-400K/6p
300-400K/6p

250-400K/8p

5
4

300-400K/8p
300-401K/8p

250-401K/6p
10

H
[ft]
2
5
700

1000

Q[US.gpm]
1000

2000
IM.gpm

3000

4000

2000

5000

3000

4000

10000
5000

20000
10000

Amarex KRT 350-.../400-.../500-.../600-.../700-.../900-..., n = 1160/875/700/585 rpm, K impeller


m/h

500

1000

200

300

2000

300

400

3000
l/s

500

4000

5000

10000

1000

2000

3000

400-900K/8p
200
350-630K/6p

350-710K/8p

50

350-636K/8p

40

500-900K/10p
400-710K/8p

100

350-630K/6p

30
350-500K/6p
700-901K/10p
20

500-710K/8p
350-420K/6p

50

400-630K/8p

350-500K/8p
600-710K/10p

40
350-501K/10p

10

30

600-710K/12p

350-500K/10p
400-500K/10p

400-500K/8p

700-900K/12p

500-630K/8p

20
H
[ft]

350-501K/8p

600-520K/10p
4

500-630K/10p
10

3
500-630K/12p
2

6
2000

3000
2000

22

Amarex KRT

4000
3000

5000
4000

Q[US.gpm]
5000

10000
IM.gpm

20000
10000

30000
20000

40000
30000

50000
40000

Waste Water
Submersible Motor Pump
Amarex KRT, n = 1750/1160/875 rpm, D impeller
30

40
10

200

50

m/h

l/s

20

100

200
30

40

300

50

400

500

1000

100

200

300
50
40

100

30
150-401D/6p
20

80-315D/4p
50
100-251D/4p
40

150-400D/6p
10

30

100-315D/4p
200-400D/6p
100-316D/6p
150-315D/6p

20

5
4

200-315D/6p
10
100-251D/6p

H
[ft]

150-251D/6p

250-400D/6p

2
250-400D/8p

300-400D/8p
m

4
1

3
100

Q[US.gpm]
100

200

300

IM.gpm

200

400
300

500
400

1000
500

2000
1000

3000
2000

4000
3000

5000
4000

Amarex KRT, n = 1750/1160 rpm, E impeller


20
4

200

30
l/s

40

m/h

50

10

100

20

200

30

40

300

50

400

500

100

200
50
40

100

30

80-251E/4p
20
150-401E/6p
50
100-251E/4p
40
10
30

80-200E/4p
200-401E/6p
m

20
150-315E/6p

80-251E/6p

H
[ft]

5
4

10

7
50

Q[US.gpm]
50

IM.gpm

100

200
100

300
200

400
300

500
400

1000
500

2000
1000

3000
2000

4000
3000

Amarex KRT

23

Waste Water
Submersible Motor Pump
Amarex KRT, n = 3500/1750/1160 rpm, F impeller
0.3

0.4 0.5

m/h

l/s

0.2

0.1

300

0.3

0.4 0.5

10

20

30

40

50

100

10

20

200

30

40

300

50

400 500
100

200
100-401F/4p

50

40-250F/2p

40

80-250F/2p
100-316F/4p
100

30

80-250F/4p
100-250F/4p

20

50
150-401F/6p

40-250F/4p

40

10

30

150-315F/6p
20

5
4
80-250F/6p

10

H
[ft]
2
5
4
1 Q[US.gpm] 2
1

IM.gpm

3
2

4
3

10

20

10

30
20

40
30

50
40

100
50

200
100

300
200

400 500
300

1000

400 500

2000

1000

3000

2000

Amarex KRT, n = 3500 rpm, S impeller


0.3

0.4

0.5

m/h

l/s

0.2

0.1

400

2
0.3

0.4

0.5

10

20
3

30

40
10

100
300

40-250S/2p
200

50

40

100

30

H
[ft]
20

50
m
40

10
30
1

Q[US.gpm]
1

24

IM.gpm

Amarex KRT

3
2

4
3

5
4

10
5

20
10

30
20

40
30

50
40

100
50

200
100

Waste Water
Submersible Motor Pump
Installation type P

Installation types
Installation type S
Stationary wet installation (S1 operation with submerged
motor)

Guide cable arrangement

Transportable wet installation (S1 operation with submerged


motor)

Guide rail arrangement

Installation type D
Stationary dry installation, vertical (S1 operation)

Installation type K
Stationary wet installation (S1 operation motor outside the
fluid)

Guide cable arrangement

Guide rail arrangement

Installation type H
Stationary dry installation, horizontal (S1 operation)

Amarex KRT

25

Waste Water
Submersible Motor Pump
General assembly drawings with list of components
Amarex KRT, 5.5 hp to 40.0 hp
Example: Amarex KRT E 150-315/20 6 WG

Motors:
5 2 ... 25 2
4 4 ... 29 4
4 6 ... 26 6

X
503

811

210

330

433.01

410

410

113

433.02

X
101

502

230

900

List of components
Part No.
101
113
210
230
330
410

26

Description
Pump casing
Intermediate casing
Shaft
Impeller
Bearing bracket
Profile joint

Amarex KRT

Part No.
433.01/02
502
503
811
900

Description
Mechanical seal
Casing wear ring
Impeller wear ring
Motor housing
Screw

Waste Water
Submersible Motor Pump
Amarex KRT, 36.0 hp to 80.0 hp
Example: Amarex KRT E/K 150-401/65 4 XG

Motors:
29 4 ... 65 4
20 6 ... 50 6
10 8 ... 35 8

811
503

210

330

412

113

900

502

230

101

List of components
Part No.
101
113
210
230
330

Description
Pump casing
Intermediate casing
Shaft
Impeller
Bearing bracket

Part No.
412
502
503
811
900

Description
O-ring
Casing wear ring
Impeller wear ring
Motor housing
Screw

Amarex KRT

27

Waste Water
Submersible Motor Pump
Amarex KRT, 6.5 hp to 50.0 hp
Example: Amarex KRT D 300-400 / 21 8 XG

Motors:
5 4 ... 65 4
4 6 ... 50 6
10 8 ... 26 8

811

210

900
410
330
433.01
900

433.02
113
230
410
101

502

List of components
Part No.
101
113
210
230
330

28

Description
Pump casing
Intermediate casing
Shaft
Impeller
Bearing bracket

Amarex KRT

Part No.
410
433.01/02
502
811
900

Description
Profile joint
Mechanical seal
Casing wear ring
Motor housing
Screw

Waste Water
Submersible Motor Pump
Amarex KRT, 47.0 hp to 640.0 hp, without cooling jacket
Example: Amarex KRT K 150-401 / 130 4 XNG-S without cooling jacket

Motors:
80 4 N ... 350 4 N
60 6 N ... 480 6 N
50 8 N ... 400 8 N
40 10 N ... 350 10 N
105 12 N ... 310 12 N

811

210
410
433.01

900

350
433.02

163

230
502
101

List of components
Part No.
101
163
210
230
350

Description
Pump casing
Discharge cover
Shaft
Impeller
Bearing housing

Part No.
410
433.01/02
502
811
900

Description
Profile joint
Mechanical seal
Casing wear ring
Motor housing
Screw

Amarex KRT

29

Waste Water
Submersible Motor Pump
Amarex KRT, 47.0 hp to 640.0 hp, with cooling jacket
Example: Amarex KRT K 150-401 / 130 4 XNG-K with cooling jacket

Motors:
80 4 N ... 350 4 N
60 6 N ... 480 6 N
50 8 N ... 400 8 N
40 10 N ... 350 10 N
105 12 N ... 310 12 N

811

210

350
900
433.01
433.02
163
410
101
230

502

List of components
Part No.
101
163
210
230
350

30

Description
Pump casing
Discharge cover
Shaft
Impeller
Bearing housing

Amarex KRT

Part No.
410
433.01/02
502
811
900

Description
Profile joint
Mechanical seal
Casing wear ring
Motor housing
Screw

03.11.2014
2553.524/07

KSB, Inc.
4415 Sarellen Road Richmond, VA 23231
Phone: (804) 222-1818 Fax: (804) 226-6961 www.ksbusa.com
KSB PUMPS Inc.
5885 Kennedy Road Mississauga Ontario L 4Z 2G3
Phone: (905) 568-9200 Fax: (905) 568-3740 www.ksb.ca