www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
1
11/4/2015
Specifier's comments:
1 Input data
Anchor type and diameter:
Material:
B500B
ETA 07/0260
Issued I Valid:
6/26/2013 | 5/16/2018
Proof:
Design method SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation:
eb = 0 mm (no stand-off); t = 25 mm
Anchor plate:
Profile:
Base material:
cracked concrete, C30/37, fc = 30.00 N/mm2; h = 10000 mm, Temp. short/long: 30/40 C
Installation:
Reinforcement:
no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
with longitudinal edge reinforcement d >= 12 + close mesh (stirrups, hangers) s <=
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
11/4/2015
Shear force y
7.500
7.500
Tension
1
Steel Strength*
Capacity [kN]
123.571
Utilization bN [%]
33
Status
OK
44.395
43.540
102
not recommended
44.395
164.577
27
OK
N/A
N/A
N/A
N/A
Splitting failure**
* anchor having the highest loading
gM,s
1.400
NRd,s [kN]
123.571
NSd [kN]
40.702
A0p,N [mm2]
138667
yA,Np
1.537
2
tRk,ucr,25 [N/mm ]
6.50
scr,Np [mm]
372
yc
1.040
2
tRk,cr [N/mm ]
3.12
yg,Np
1.368
yg,Np
1.098
ec1,N [mm]
0
yec1,Np
1.000
ec2,N [mm]
83
yec2,Np
0.691
ys,Np
1.000
N0Rk,p [kN]
78.413
NRk,p [kN]
91.433
gM,p
2.100
NRd,p [kN]
43.540
NSd [kN]
44.395
ccr,Np [mm]
186
cmin [mm]
yre,Np
1.000
A0c,N [mm2]
1440000
yA,N
1.167
ccr,N [mm]
600
scr,N [mm]
1200
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
83
yec2,N
0.878
ys,N
1.000
N0Rk,c [kN]
337.397
gM,c
2.100
NRd,c [kN]
164.577
NSd [kN]
44.395
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
yre,N
1.000
k1
7.700
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
3
11/4/2015
Utilization bV [%]
14
Status
OK
N/A
N/A
N/A
N/A
15.297
176.493
OK
N/A
N/A
N/A
N/A
Capacity [kN]
57.333
gM,s
1.500
VRd,s [kN]
57.333
VSd [kN]
7.649
A0p,N [mm2]
138667
yA,Np
1.167
2
tRk,ucr,25 [N/mm ]
6.50
ccr,Np [mm]
186
scr,Np [mm]
372
yc
1.040
2
tRk,cr [N/mm ]
3.12
k-factor
2.000
yg,Np
1.368
yg,Np
1.098
ys,Np
1.000
ec1,V [mm]
0
yec1,Np
1.000
ec2,V [mm]
0
yec2,Np
1.000
yre,Np
1.000
N0Rk,p [kN]
78.413
NRk,p [kN]
132.370
gM,c,p
1.500
VRd,c1 [kN]
176.493
VSd [kN]
15.297
cmin [mm]
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
steel
bN
0.329
bV
0.133
a
2.000
Status
OK
concrete
1.020
0.087
1.500
106
not recommended
bN + bV <= 1
30.149 [kN]
dN
0.300 [mm]
VSk
5.666 [kN]
dV
0.227 [mm]
dNV
0.376 [mm]
30.149 [kN]
dN
0.648 [mm]
VSk
5.666 [kN]
dV
0.283 [mm]
dNV
0.707 [mm]
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
4
11/4/2015
7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can
be
achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Characteristic bond resistances depend on short- and long-term temperatures.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient sompressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
11/4/2015
8 Installation data
Anchor plate, steel: Profile: Pipe; 140 x 140 x 13 mm
Hole diameter in the fixture: df = 20 mm
Plate thickness (input): 25 mm
Recommended plate thickness: not calculated
Cleaning: Premium cleaning of the drilled hole is required
Cleaning
Compressed air with required
accessories to blow from the bottom of
the hole
Proper diameter wire brush
y
100
50
100
Setting
Dispenser including cassette and mixer
For deep installations, a piston plug is
necessary
Dynamic set
Torque wrench
200
150
150
50
100
100
x
0
0
y
-100
100
c-x
-
c+x
-
c-y
-
c+y
-
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project:
Sub-Project I Pos. No.:
Date:
6
11/4/2015
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan