Anda di halaman 1dari 6

Profis Anchor 2.5.

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

1
11/4/2015

Specifier's comments:

1 Input data
Anchor type and diameter:

HIT-RE 500-SD + Rebar 20mm

Dynamic set or any suitable annular gap filling solution


Effective embedment depth:

hef,opti = 400 mm (hef,limit = 400 mm)

Material:

B500B

Evaluation Service Report:

ETA 07/0260

Issued I Valid:

6/26/2013 | 5/16/2018

Proof:

Design method SOFA design method + fib (07/2011) - after ETAG BOND testing

Stand-off installation:

eb = 0 mm (no stand-off); t = 25 mm

Anchor plate:

lx x ly x t = 200 mm x 300 mm x 25 mm; (Recommended plate thickness: not calculated)

Profile:

Pipe; (L x W x T) = 140 mm x 140 mm x 13 mm

Base material:

cracked concrete, C30/37, fc = 30.00 N/mm2; h = 10000 mm, Temp. short/long: 30/40 C

Installation:

hammer drilled hole, Installation condition: Dry

Reinforcement:

no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
with longitudinal edge reinforcement d >= 12 + close mesh (stirrups, hangers) s <=

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

11/4/2015

2 Load case/Resulting anchor forces


Compression
y2

Load case: Design loads


Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Tension force
Shear force
Shear force x
Anchor
1
40.702
7.649
1.500
2
3.694
7.649
1.500
max. concrete compressive strain:
0.28 []
max. concrete compressive stress:
8.38 [N/mm2]
resulting tension force in (x/y)=(0/-83):
44.395 [kN]
resulting compression force in (x/y)=(63/126): 19.395 [kN]

Shear force y
7.500
7.500

Tension
1

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN]
40.702

Steel Strength*

Capacity [kN]
123.571

Utilization bN [%]
33

Status
OK

Combined pullout-concrete cone failure**

44.395

43.540

102

not recommended

Concrete Breakout Strength**

44.395

164.577

27

OK

N/A

N/A

N/A

N/A

Splitting failure**
* anchor having the highest loading

**anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN]
173.000

gM,s
1.400

NRd,s [kN]
123.571

NSd [kN]
40.702

3.2 Combined pullout-concrete cone failure


Ap,N [mm2]
213143

A0p,N [mm2]
138667

yA,Np
1.537

2
tRk,ucr,25 [N/mm ]
6.50

scr,Np [mm]
372

yc
1.040

2
tRk,cr [N/mm ]
3.12

max tRk,cr [N/mm2]


13.42

yg,Np
1.368

yg,Np
1.098

ec1,N [mm]
0

yec1,Np
1.000

ec2,N [mm]
83

yec2,Np
0.691

ys,Np
1.000

N0Rk,p [kN]
78.413

NRk,p [kN]
91.433

gM,p
2.100

NRd,p [kN]
43.540

NSd [kN]
44.395

ccr,Np [mm]
186

cmin [mm]

yre,Np
1.000

3.3 Concrete Breakout Strength


Ac,N [mm2]
1680000

A0c,N [mm2]
1440000

yA,N
1.167

ccr,N [mm]
600

scr,N [mm]
1200

ec1,N [mm]
0

yec1,N
1.000

ec2,N [mm]
83

yec2,N
0.878

ys,N
1.000

N0Rk,c [kN]
337.397

gM,c
2.100

NRd,c [kN]
164.577

NSd [kN]
44.395

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

yre,N
1.000

k1
7.700

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

3
11/4/2015

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN]
7.649

Steel Strength (without lever arm)*


Steel failure (with lever arm)*
Pryout Strength**

Utilization bV [%]
14

Status
OK
N/A

N/A

N/A

N/A

15.297

176.493

OK

N/A

N/A

N/A

N/A

Concrete edge failure in direction **


* anchor having the highest loading

Capacity [kN]
57.333

**anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN]
86.000

gM,s
1.500

VRd,s [kN]
57.333

VSd [kN]
7.649

4.2 Pryout Strength (Bond Strength controls)


Ap,N [mm2]
213143

A0p,N [mm2]
138667

yA,Np
1.167

2
tRk,ucr,25 [N/mm ]
6.50

ccr,Np [mm]
186

scr,Np [mm]
372

yc
1.040

2
tRk,cr [N/mm ]
3.12

max tRk,cr [N/mm2]


13.42

k-factor
2.000

yg,Np
1.368

yg,Np
1.098

ys,Np
1.000

ec1,V [mm]
0

yec1,Np
1.000

ec2,V [mm]
0

yec2,Np
1.000

yre,Np
1.000

N0Rk,p [kN]
78.413

NRk,p [kN]
132.370

gM,c,p
1.500

VRd,c1 [kN]
176.493

VSd [kN]
15.297

cmin [mm]

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
steel

bN
0.329

bV
0.133

a
2.000

Utilization bN,V [%]


13

Status
OK

concrete

1.020

0.087

1.500

106

not recommended

bN + bV <= 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk

30.149 [kN]

dN

0.300 [mm]

VSk

5.666 [kN]

dV

0.227 [mm]

dNV

0.376 [mm]

Long term loading:


NSk

30.149 [kN]

dN

0.648 [mm]

VSk

5.666 [kN]

dV

0.283 [mm]

dNV

0.707 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

4
11/4/2015

7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can
be

achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Characteristic bond resistances depend on short- and long-term temperatures.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient sompressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Fastening does not meet the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

11/4/2015

8 Installation data
Anchor plate, steel: Profile: Pipe; 140 x 140 x 13 mm
Hole diameter in the fixture: df = 20 mm
Plate thickness (input): 25 mm
Recommended plate thickness: not calculated
Cleaning: Premium cleaning of the drilled hole is required

Anchor type and diameter: HIT-RE 500-SD + Rebar 20mm


Installation torque: 0.000 kNm
Hole diameter in the base material: 25 mm
Hole depth in the base material: 400 mm
Minimum thickness of the base material: 450 mm

8.1 Recommended accessories


Drilling
Suitable Rotary Hammer
Properly sized drill bit

Cleaning
Compressed air with required
accessories to blow from the bottom of
the hole
Proper diameter wire brush
y

100

50

100

Setting
Dispenser including cassette and mixer
For deep installations, a piston plug is
necessary
Dynamic set
Torque wrench

200

150

150

50

100

100

Coordinates Anchor [mm]


Anchor
1
2

x
0
0

y
-100
100

c-x
-

c+x
-

c-y
-

c+y
-

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

6
11/4/2015

9 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Anda mungkin juga menyukai