Anda di halaman 1dari 4

ROOF AND RAINWATER DOWN PIPE

ITEM

DESCRIPTION

UNIT

QTY

RATE

AMOUNT

ROOF STRUCTURE
SUPPLY AND DELIVER TO SITE AND INSTAL MILD
STEEL ROOF TRUSSES INCLUDING RAFTERS, WALL
PLATES, TIES AND STRUTS INCLUDING ALL
NECESSARY BOLTS AND NUTS, CUT, LABOUR,
WELDED AND FRAME TOGETHER AND ALL
NECESSARY
PAINTINGS,
LABOUR,
MATERIAL,
APPLIANCES ALL AS SHOWN AND DESCRIBED IN
ENGINEER'S DRAWINGS
a.

20 Profile pitch roof and hoisting to 4400mm from ground level.


measured on plan.

M2

400

b.

8 Profile pitch roof ,easured on plan (Gym room)

M2

24

c.

3 Profile pitch roof measured on plan.

M2

63

M2

487

ROOF COVERING

d.

"KLIPLOK 0.54MM TCT IMPROVED CLEAN


COLOURBOND (R) XRW" METEL ROOF COVERINGS LAID
ON MILD STEEL ROOF TRUSS AND PURLINS (ROOF
TRUSS AND PURLINS MEASURED SEPERATELY)
INCLUDING ALL NECESSARY ROOF ACCESSORIES AS
SHOWN ON ARCHITECTURAL DRAWINGS.

ROOF ACCESSORIES
e.

Ridge capping (maximum girth 578mm up to 3 bends) in


improved clean COLORBOND XRW steel with allowance made
for lapping, comes complete with CS12-14 x 20mm (Class 3
fasterners conforming to AS3566.2 - 2002) OR OTHER
APPROVED AND EQUIVALENT

f.

Steel Valey gutter, ditto.

11

g.

Fascia Board

82

h.

200mm x 200mm Steel Gutter

82

i.

Steel Gutter Clip c/c 500mm

Nos

164

k.

'C' Channel with 6100mm laid on roof (Gym room)

Nos

l.

L plate c/w bolt and nut (Gym room)

Nos

24

M2

487

67
-

ROOF INSULATION
g.

Layer of double sided aluminium foil roofing paper laid on and


including a layer of approved galvanised iron chichen wire mesh
and lapped at joints (measured nett-no allowance made for laps)

ROOF AND RAINWATER DOWN PIPE


ITEM

DESCRIPTION

UNIT

QTY

82

RATE

AMOUNT

KNOT, PRIME, STOP AND PREPARE AND APPLY ONE COAT


PRIMER AND TWO COATS OF APPROVED GLOSS
ENAMELLED PAINT TO:E

General surfaces of fascia board, exceeding 200 mm and not


exceeding 300 mm wide

C1 / 12

ROOF AND RAINWATER DOWN PIPE


ITEM

DESCRIPTION

UNIT

QTY

RATE

AMOUNT

RAINWATER DOWN PIPE


UPVC PIPES TO B.S 4514, B.S. 5255 AND B.S. 4660 including
all necessary jointing to other sizes of pipes, connectors, fittings
and fixing as specified finished with and including three coats
clear silicone paint :a.

100 mm Diameter (internal dimension) laid and jointed in trench

b.

100 mm Diameter (internal dimension) fixed to wall and column


including holderbats, part embedded to r.c. column.

EXTRAOVER for elbow and other requisite fittings (irrespective


No.
of fittings)

100 mm Diameter approved UPVC vent cowl grating fixed and set
No.
on top of rainwater downpipe (measured separately)

50mm dia nozzle

10

c.

d.

e.

No.

C1 / 13

ROOF AND RAINWATER DOWN PIPE


ITEM

DESCRIPTION

UNIT

QTY

RATE

AMOUNT

COLLECTION PAGE

From Page No. C1 / 12..

From Page No. C1 / 13..

C1 / 14

Anda mungkin juga menyukai