Anda di halaman 1dari 101

HANDBOOK for

FTTH OSP (PT TELKOM INDONESIA)

HANDBOOK
For

Outside PlantPlant-Fiber to the Home


(FTTH(FTTH-OSP)
For
PT TELKOM INDONESIA
V 1.0

<REFERENCE or DESIGN,
WORK IMPLEMENTATION & TESTING>
(June 2013)
CopyrightFujikura Ltd./Y.N

Page 1

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Contents
PART-I DESIGN & INSTALLATION

........................................................................

FTTH-OSP DESIGN PRINCIPLES


..........................................................................
MATERIALS FOR FTTH-OSP (STO - ODP)
..........................................................................
MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) .........................................................

1.

2.

5
7
8

FEEDER CABLE DESIGN

++++++++..+++.+++++++... 11

1.1 Google Map


1.2 Skema Kabel Feeder
1.3 PetaLokasi Duct & Kabel Feeder
1.4 Sample Design of Feeder Cable Network
1.5 Core Assignment Diagram
1.6 General Concept for Feeder Cable Design

/////////..........................................
////..///////////.............../.
//////////.///..///////.
/////.//.//////////.............
/////////././///.//////..
/////./..///////////............

11
12
15
15
19
22

DISTRIBUTION CABLE DESIGN

++++++++.+++++++++++

25

2.1 Google Map


////////..////////////...
2.2 Skema Kabel Distribusi
/////////..////////////
2.3 Sample Design of Distribution Cable Network /////.////////////............
2.4 Branching ODP
//////..////////////..........
2.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) ..........................

3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ++++++++.............


3.1 Duct / Buried Section
3.2 Aerial Section

4.

25
25
28
32
33

34

/////.////////////............... 34
/..////////////............................ 37

CABLE RACK / OTB RACK IN STO BUILDING +++++..+++.+++++++++ 41

CopyrightFujikura Ltd./Y.N

Page 2

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
5.

6.

HIGH-RISE BUILDING (HRB) DESIGN

......................................................................... 42

5.1 Materials for HRB Solution


5.2 Design Concept for HRB Solution
5.3 Type of ODC for High-Rise-Building
5.4 Example of Cable Tray/Trunking
5.5 Sample Design: Skema Distribusi
5.6 Sample Design: Peta Lokasi Distribusi

/////////...........................................
////..///////////.............../..
//////////.///..///////..
/////.//.//////////.............
/////////././///.//////..
/////./..///////////............

42
43
44
45
46
47

REFERENCE

++++++++.+++++++++++

50

6.1 Pondasi ODC-C-144 Splitter


////////..////////////...
6.2 Pondasi ODC-C-288 Splitter
/////////..///////////...
6.3 Pondasi ODP Pedestal & HH-PIT-60
/////.////////////..............
6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) .../..////////////..........
6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) ..............................................................
6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) ..............................................................
6.7 Installation of ODP Wall
............................................................................
6.8 Form for Core Assignment Diagram
............................................................................
6.9 Installation Check Sheet
............................................................................
6.10 List of Assembly Unit Designator
............................................................................

51
52
53
54
55
56
57
59
63
67

PART-II ACCEPTANCE TESTING


1. TEST PROCEDURE

........................................................................ 73
+++++++++++................................ 74

2.

OPM MEASUREMENT

......................................................................... 86

2.1 Application of Measurement Forms


2.2 Measurement Forms

/////.////////////............... 87
/..////////////............................ 92

CopyrightFujikura Ltd./Y.N

Page 3

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

CopyrightFujikura Ltd./Y.N

Page 4

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

FTTH-OSP DESIGN PRINCIPLES (1)


1.

FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordance
with the frame of this document.

2.

LINK BUDGET
1) Descriptions in the Contract:
The Design shall ensure the FTTH OSP System Power Budget of the GPON OLT
to ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shall
be 28dB (including the margin of 3dB).
2) Applicable Power Budget in the Project:
 Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ Wave
Length 1310nm=0.35dB/km)
 Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional
Margin due to an incidental increment of the loss in OSP during an operation)
 Link Budget to be applied for the Project: 25dB @ 1310nm
 We may try however, to keep 23dB @ 1310nm as far as practicable.

CopyrightFujikura Ltd./Y.N

Page 5

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

FTTH-OSP DESIGN PRINCIPLES (2)


3.
3.1

FTTH OSP Design shall be composed of the following:


Feeder Cable Design
1) Google Map per STO
2) Skema Kabel Feeder (Schematic Drawing)
3) Skema Duct (Schematic Drawing)
4) Peta Lokasi Duct & Kabel Feeder (Location Map)
5) Special Design (MH Modification, Duct Bridge etc.)

3.2

Distribution Cable Design


1) Google Map per Lokasi
2) Skema Kabel Distibusi
3) Peta Lokasi Distribusi
4) Special Design (HH Modification, Modified ODP Foundation etc.)

CopyrightFujikura Ltd./Y.N

Page 6

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Materials for FTTH OSP (STO - ODP)
Distribution Cable
(Aerial)

ODP (Wall Mount)


ODP-PW-8/16

AC-OF-SM-8/12/24-SC
ODP (Aerial)
ODP-SSW-8
(1:8 Splitter built-in)

Line Guard/
Suspension
Branching ODP

C-Clamp

(Pedestal)

Branching ODP
ODP-PL-BR

(Pole/Wall Mount)

ODP (Pedestal)

ODP-PW-BR

ODPPL-8/16

ODC
ODC-C-48/144/288 Splitter
Note: ODC-C-48 = Wallmount Type

Passive Splitter
PS-1-2-ODC/
PS-1-4-ODC

PS-1-8-ODP

Inline closure

Type/Designator

for 12c-24c

SC-OF-SM-24

for 12c-48c

SC-OF-SM-48

for 12c-96c

SC-OF-SM-96

for 12c-144c

SC-OF-SM-144

for 12c-288c

SC-OF-SM-288

ODC

Distribution Cable
(Duct)
STO

Feeder Cable

DC-OF-SM-8/12/24-SC

DC-OF-SM12D/24D/48D/
96D/144D/288D

OTB
TC-OF-SM12/24/48/72/96/144
CopyrightFujikura Ltd./Y.N

Page 7

Pass through closure

Type/Designator

for 48core Star/Ring

SC-OF-SM-PT-48

for 96core Star/Ring, 144core Star

SC-OF-SM-PT-144S

for 144core Ring

SC-OF-SM-PT-144R

for 288core Star

SC-OF-SM-PT-288S

for 288core Ring

SC-OF-SM-PT-288R

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Materials for FTTH-OSP (HRB: High-Rise Building)
Indoor Cable
(2-C Low Friction)

ODP-HRB
ODP-HRB-16/32

PS-1-8-ODP-HRB

IC-OF-SM-2D

Indoor Cable
(1-C Low Friction)
IC-OF-SM-1D

FUSE-CONNECT
ISC-UPC-FD

Splitter for ODC-HRB


ROSETTE

PS-1-4-ODC-HRB

RS-IN-SC-1P/
TC-MK-SC-1P

ODC-HRB

ODC-HRB-420
ODC-HRB-240
ODC-HRB-180

19 inch Rack

ODC-HRB(Rack)

ODC-HRB (Cabinet)

or

ODC-HRB-RACK-480
ODC-HRB-RACK-240
ODC-HRB-RACK-120

Cable Trunking and Accessories

TC-OF-R-19

Cable Trunking

CopyrightFujikura Ltd./Y.N

Page 8

Elbow (Flat Angle)

T-Joint

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF MATERIALS AND INSTALLATION MANUALS (1/2)
No.
1 - 5.
6
7 - 8.
9 - 12.
13-16
17 - 20
21-23
24
25 - 26
49 - 50
51 - 52
53 - 54
55 - 56
57 - 75
76 - 78
79
80-81
82 - 83
84 - 87
88 - 89
90 - 95
96
97
98
99-101
102 - 106
107 - 111
112 - 116
117 - 121
200
201
202
203
204

Spec.No.

Name File

As of:

Manual.No.

01-June-2013

Sub manuals

ESMDDLT000*****K

DC-OF-SM-*D (SM.D D - LT */*T)


DC-OF-SM-288D (SM.D D - LT 288/24T)
DC-OF-SM-*D (OG8ETSWBE)
AC-OF-SM-*D (SM.D A - LT */*T)
DC-OF-SM-*C (NZDS.C D - LT */*T)
AC-OF-SM-*C (NZDS.C A - LT */*T)
DC-OF-SM-*-SC (SM.D D - LT */*T)
AC-OF-SM-8-SC (OGGDE-SSW)
AC-OF-SM-*-SC (OGNM4WTGDE-SSW)
GC-OF-SM-1D (FR-OGINE)
HC-OF-SM-*D (FR-OGNMGDE-SSD)
GC-OF-SM-1D (FR-OGINE)
Patch cord (2.8mm, BIS-B)
Pigtails and Patchcords
ODC-C-* Splitter
ODC-C-48 Splitter
ODC-CU (FSCO-HHS)
ODP-CA-* for Pole Mount
ODP-A-*
ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount)
TC-SM-*
RS-IN-SC-1P (FPB-103A(S))
RS-IN-SC-2P (FPB-302-2SC(PT))
RS-IN-SC-4P (RS-IN-SC-4)
TC-MK-SC-*
PS-1-*-ODC (Optical Spitter Module 1 x N Type)
PS-1-*-ODP(PLC Type 1xN Splitter)
PS-2-*-ODC (Optical Spitter Module 2 x N Type)
PS-2-*-ODP (PLC Type 2xN Splitter)
Deadending Wire Vice (C clamp)
Drop Cable Clamp (S Clamp)
House Hook
Cable cleat
Selft-Support Wire Line Guard (Line Guard 2.6mm)

ESMDDLT00028824K
JBT-05166A
ESMDALT0000****K
ENZDSCDLT0*****K
ENZDSCALT00****K
ESMDDLT0000****K
JBT-05027B
JBT-05026-> JBT-05391
JBT-04109A
JBT-04770D
JBT-04109A
PNJHC-1101-54-02(2.8mm)
TS1211-01
PNJBC-0516-54-03
PNJBC-0516-54-04
PNJCS-0013-54-10
PNJCY-0085-54-03
PNJBC-0516-54-06
JEMBO Pedestal + ODP-CA
PNJBC-0516-54-07
PNJBC-0470-54-04
PNJBC-0472-54-08A
PNJBC-0516-54-08
PNJBC-0516-54-09
PNJBC-0516-54-10
PNJSC-1077-54-03Rev.1
PNJBC-0516-54-11
PNJSC-1077-54-04Rev.1
PNJCY-0084-54-02
PNJCY-0084-54-01
PNJCY-0084-54-04
PNJCY-0084-54-03
PNJCY-0084-54-05

PNJBC-0516-82-01
PNJBC-0516-82-01

ODC-C sub manual_130214


ODC-C sub manual_130214

PNJCY-0085-82-01

ODP-CA sub manual_130323

PNJCY-0085-82-01
PNJBC-0516-82-04
PNJBC-0470-82-02

TC-SM sub manual_130225

PNJBC-0516-82-06

Manauals not applicable


Manuals will be available upon supply of the material
CopyrightFujikura Ltd./Y.N

Page 9

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF MATERIALS AND INSTALLATION MANUALS 2/2)
205
206
207
400 - 401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427

Spec.No.

Name File

No.

L-clamp
Flex Band IBT-206
BW-Clamp
Free Bending Optical cord (3mm, BIS-B)
ODP-SSW (FSCO-AS-SP(in/splice))
FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO)
FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT)
FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30)
FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable
FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port
Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port
ODP-BR for Branching (3 Hole Type) , Pole mounting type
ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal
ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 Port
ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port
Low Friction Indoor Cable , 1C
Low Friction Indoor Cable , 2C
Pass through closureType1 ( For 48core Star/Ring )
Pass through closureType2 ( For 96core Star/Ring )
Pass through closureType3 ( For 144core Ring )
Pass through closureType4 ( For 288core Star)
Pass through closureType4 ( For 288core Ring)
ODC-HRB-420
ODC-HRB-240
ODC-HRB-180
ODP-HRB-32
ODP-HRB-16
PS-1-8-ODP-HRB
PS-1-4-ODC-HRB

PNJCY-0084-54-06
PNJCY-0084-54-07
PNJCY-0084-54-08
PNJHC-1101-53-01
PNJCY-0067-54-18
PNJHY-0001-53-11
PNJHY-0001-53-10
PNJHY-0107-53-05
PNJHY-0107-54-21Rev.2
PNJHY-0107-54-21Rev.2
PNJBC-0480-54-17
PNJBC-0480-54-17
PNJBC-0480-54-17
B-12F0401
B-12F0401
PNJBC-0085-54-02
PNJBC-0085-54-02
JBT-04260B
JBT-04260B

PNJBC-0516-54-12
PNJBC-0516-54-12
PNJBC-0516-54-12
PNJBC-0516-54-13
PNJBC-0516-54-13
PNJBC-0527-54-07
PNJBC-1077-54-03Rev.1

As of:

Manual.No.

01-June-2013

Sub manuals

PNJC-0067-82-04

JDAA-11-12-0048D
JDAA-11-13-0075

PNJCY-0085-82-03
PNJCY-0085-82-03
PNJCY-0085-82-01
PNJCY-0085-82-01

PNJBC-0516-82-09A
PNJBC-0516-82-09A
PNJBC-0516-82-09A
PNJBC-0516-82-10
PNJBC-0516-82-11

Manauals not applicable


Manuals will be available upon supply of the material

CopyrightFujikura Ltd./Y.N

Page 10

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.

FEEDER CABLE DESIGN

A. The Feeder Cable Route shall be planned to utilize the existing duct route as
the first priority so as to minimize the road excavation length.
B. The capacity of Feeder Cables designed/implemented by the previous
TOS/PO as well as for the followings shall be taken into account at the
Feeder Cable Capacity Planning:
1) AL PRO: Existing Facility such as MSAN, RK, etc.
2) Node B Project
3) GDI: Government Digitalization Network

1.1

GOOGLE MAP
1) Nama STO: legend berbentuk Rumah (Warna Merah)
2) Route Feeder: warna Merah
3) Nama ODC sesuai dengan Lokasi/Cluster
4) Kapasitas ODC/ Jumlah Homepass
5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi

CopyrightFujikura Ltd./Y.N

Page 11

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.2

SKEMA KABEL FEEDER


Purpose: Information required for the Feeder Cable Work

A. OTB at STO
OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ:

Example: TC-OF-SM-xx (yy)


Total Quantity of OTB
Type of OTB
B. Feeder Cable
Indication: Black Line (New: 0.6 point, Existing: 0.3 point)
Information:
1) Type (Duct/Aerial) and capacity of cable
2) Length of cable
3) Core Assignment

Note: The younger core number shall be assigned for the far end (the last position) and
spare cores (Cadangan).

CopyrightFujikura Ltd./Y.N

Page 12

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
IDENTIFICATION OF FEEDER CABLE

Code STO
Code Feeder Cable
Feeder No.
Note:
Cable Line:
 New: Tebal (e.g. 6pt.)
 Existing: Tipis (e.g. 3pt.)
Identification:
 New: Bold Font
 Existiong: Normal Font

Segment No.
Branch-Segment No.
Core No. In Cable

FE XXX 01-01-01 (01-288)


DC-OF-SM-XXX-xxxxM
Cable Length
in meter

Type of Cable
Duct Cable: DC-OF-SM
Aerial Cable: AC-OF-SM

CopyrightFujikura Ltd./Y.N

No. Of Cores

Page 13

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
C. ODC

Code ODC
Code STO
ODC No. FA, FB, .......
ODC Capacity

ODC-XXX-FA-288
xx PS 1:4 (xxx HP)
Number of Homepass
Code Splitter 1:4
Number of Splitter 1:4

Assigned core to be
terminated

Coordinates Lokasi ODC


D. MH/HH/CLOSURE
1) MH/HH: Name of Existing MH/HH or Type of New MH/HH
2) Closure:
a. Straight Joint: SC-OF-SM-xxx
b. Pass-through Joint: SC-OF-SM-xxx-PT
CopyrightFujikura Ltd./Y.N

Page 14

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.3 PETA LOKASI DUCT & KABEL FEEDER
Purpose: Information required for the Civil Work shall be plot on the scaled map

1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK


3) PETA LOKASI
KABEL FEEDER
(Refer to 1.4.3)

2) SKEMA KABEL FEEDER


(Refer to 1.4.2)

DD-ROD-1
15.0

STO
ABC
ABC
01/01

DD-BM-HDPE-1
35.0

CopyrightFujikura Ltd./Y.N

DC-OF-SM-48D ++m

FE-ABC-02-01-01 (241-288)

Lokasi DD
ODC-ABC-F+-144

ABC
01/xx

DD-ROD1
xxx.0

ABC
01/xx

DC-OF-SM-48D ++m

Lokasi DD
ODC-ABC-F+-144
xx PS 1:4 (yyHP)
(217-240)

ABC
01/xx


xxx.xxxx
E yyy yyy.yyyy

DC-OF-SM-48D ++m

DD-ROD1
1
.0

Lokasi BB
ODC-ABC-F+-288
ABC
01/yy

HH80
CAD
(01 216)

DD-ROD1
xxx.0

DD-ROD1
1
.0

DD-BM-1
10.0

ABC
02/03

DD-ROD1
1
.0

DD-ROD1
1
.0

DD-ROD1
xxx.0

ABC
02/xx
150.0

DD-BM-HDPE-1
150.0

ABC
02/02

DD-ROD1
1
.0

Lokasi CC
ODC-ABC-F+-288

HH-1
DD-BM-1
bbb.
0


xxx.xxxx
E yyy yyy.yyyy

FE-ABC-02-02-01 (217-240)
CAD
(01 72)

ABC
01/02

ABC
01/03

FE-ABC-01-02-01 (73-120)

HH-1

JL

Lokasi AA
ODC-ABC-F+-144

HH-2

Lokasi CC
ODC-ABC-F+-288
xx PS 1:4 (yyHP)
(241-288)

ABC
02/01

100.0

10.0

HH-1
aaa.
0


xxx.xxxx
E yyy yyy.yyyy

Cable Slack (10m) shall be


placed every 1000m of
cable span and/or the
location where the future
demand is expected.

DD-ROD1
1
.0

DD-BM-HDPE-BIG-1
JL

JL
FE-ABC-0202
(01-240)
DC-OF-SM-288D
++m

DC-OF-SM-144D
++m

FE-ABC-0202
(01-240)
DC-OF-SM-288D
++m

Lokasi BB
ODC-ABC-F+-288
xx PS 1:4 (yyHP)
(73-120)

ABC
01/yy

DD-BMHDPEBIG-1
bbb.
0

HH-1

JL

ABC
02/02


xxx.xxxx
E yyy yyy.yyyy

Lokasi CC
ODC-ABC-F+-288

FE-ABC-01-02 (01-120)

DD-BM-HDPE-BIG-1

Lokasi AA
ODC-ABC-F+-144
xx PS 1:4 (yyHP)
(121-144)

HH-1

DD-BMHDPEBIG-1

Cable slack (10) shall be provided at


every 1000m of cable length. (In case
of DD-BM-HDPE, HH-1/2 shall be
installed.)

ABC
01/02

DC-OF-SM-24D ++m

ABC
02/xx

ABC
02/01
JL

ABC
01/02

HH80

ABC
01/yy

Lokasi BB
ODC-ABC-F+-288

100.0

ABC
01/xx

ABC
01/03
JL

DD-BM-HDPE-1
150.0

100.0

HH-2

FE-ABC-02-01 (01-288)

FE-ABC-01-01-01 (121-144)

6
100.0

150.0

Lokasi AA
ODC-ABC-F+-144

100.0

6
100.0

aaa.0

15.0

JL

STO
ABC

FE-ABC-01-01 (01-144)
DC-OF-SM-144D ++m

ABC
01/01

24

DC-OF-SM-288D
++m

JL

DD-ROD1
1
.0

DD-BM-HDPEBIG-1

TC-SM-144 (3)

DD-BM-HDPEBIG-1

STO ABC

DD-ROD-1
xxxx.0

Legend:
: Assigned Duct for New Cable
: Vacant Duct
: Occupied Duct

JL

1) SKEMA DUCT
(Refer to 1.4.1)

Lokasi DD
ODC-ABC-F+-144

HH-1

DD-BM-HDPE-1
35.0

Page 15

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.4.1

SKEMA DUCT
Lokasi BB

Lokasi AA

ODC-ABC-F+-288

ODC-ABC-F+-144
STO ABC
DD-BM-HDPE-1
150.0

ABC
01/03

35.0

6
100.0

JL

DD-BM-HDPEBIG-1

DD-BM-HDPEHH-1
BIG-1

DD-BM-HDPEBIG-1
ABC
02/xx

HH-1

Lokasi DD

Lokasi CC

ODC-ABC-F+-144

ODC-ABC-F+-288

CopyrightFujikura Ltd./Y.N

Page 16

Legend:
: Assigned Duct for New Cable
: Vacant Duct
: Occupied Duct

JL

150.0

bbb.0

aaa.0

ABC
01/01

HH-1

100.0
ABC
02/01
JL

Cable slack (10) shall be provided at every 1000m


of cable length. (In case of DD-BM-HDPE, HH-1/2
according to Page 23, 1.6.3 shall be installed.)

100.0

ABC
01/02

ABC
01/xx

100.0

100.0
ABC
01/yy

24

DD-BM-HDPE-1

HH-2

15.0

HH-80

ABC
02/02

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.4.2

SKEMA KABEL FEEDER


Lokasi BB

Lokasi AA

ODC-ABC-F+-288

ODC-ABC-F+-144

xx PS 1:4 (yyHP)
(73-120)

xx PS 1:4 (yyHP)
(121-144)


xxx.xxxx
E yyy yyy.yyyy

STO ABC
TC-SM-144 (3)


xxx.xxxx
E yyy yyy.yyyy

FE-ABC-01-02-01 (73-120)

FE-ABC-01-01-01 (121-144)
DC-OF-SM-24D ++m

DC-OF-SM-48D ++m

FE-ABC-01-02 (01-120)
DC-OF-SM-144D ++m

ABC
01/yy
FE-ABC-02-02
(01-240)

CAD
(01 216)

DC-OF-SM-288D
++m

FE-ABC-02-02
(01-240)
DC-OF-SM-288D
++m

FE-ABC-01-01 (01-144)
JL

JL

ABC DC-OF-SM-144D ++m


01/02

JL

CAD
(01 72)

FE-ABC-02-01 (01-288)
DC-OF-SM-288D ++m

FE-ABC-02-02-01 (217-240)
DC-OF-SM-48D ++m

FE-ABC-02-01-01 (241-288)

Lokasi DD

ODC-ABC-F+-144
xx PS 1:4 (yyHP)
(217-240)

Cable Slack (10m) shall be


placed every 1000m of cable
span and/or the location where
the future demand is expected.
(Note: Do not show on drawing)

Lokasi CC

ODC-ABC-F+-288
xx PS 1:4 (yyHP)
(241-288)


xxx.xxxx
E yyy yyy.yyyy

CopyrightFujikura Ltd./Y.N

DC-OF-SM-48D ++m


xxx.xxxx
E yyy yyy.yyyy

Page 17

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.4.3

PETA LOKASI KABEL FEEDER

Lokasi BB
Lokasi AA

ODC-ABC-F+-288

DD-BM-HDPE-1
150.0

DD-BM-HDPE-1
35.0

ABC
01/yy

DD-ROD-1
100.0m

Lokasi DD

ODC-ABC-F+-144

DD-ROD-1
xxx.0m

DD-ROD-1
100.0m

DD-BM-HDPEBIG-1

DD-BM-1
10.0

150.0

1.
2.

DD-ROD-1
100.0m

ABC DD-ROD-1 ABC


01/03 100.0m 01/02

ABC
01/01

JL

HH-1
bbb.0

HH-2

ABC
01/xx

DD-BM-HDPEBIG-1

HH-1
aaa.0

CopyrightFujikura Ltd./Y.N

DD-ROD-1
xxx.0m

DD-ROD-1
15.0m

JL

HH-1

ABC
01/xx

ABC
01/xx

JL

DD-BM-HDPEBIG-1

STO
ABC

ODC-ABC-F+-144

HH-80

DD-BM-1
10.0

DD-ROD-1
100.0m

FE-ABC-01
FE=ABC-02

Note:
In case if plural cables
will be installed in one
(1) route, Cable No. to
be installed shall be
indicated.

ABC
02/01
DD-ROD-1
100.0m

ABC DD-ROD-1 ABC DD-ROD-1 ABC


xxx.0m
100.0m
02/02
02/03
02/xx

Lokasi CC

ODC-ABC-F+-288

Page 18

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.5 CORE ASSIGNMENT DIAGRAM


1.
2.
3.

CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABEL as a tool so as to
arrange the core assignment of the feeder cable easily. (Not for submission purpose)
CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE.
The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the
youngest number shall be assigned for the furthest ODC or CAD (Spare core).

FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION


START

1.
2.

3.
4.

SUM UP the required


number of fiber cores:
1.ODC-144: 24 cores
2.ODC-288: 48 cores

FEEDER CABLE ROUTE PLAN:


=> Draft for Skema Feeder
SKEMA DUCT EXISTING shall be referred as the
basic information for the Feeder Cable Route Plan.
Plot all ODCs TO BE FED BY THE CABLE
together with its capacity along the existing duct
route.
Where the existing duct is not available, new duct
construction or DD-BM-HDPE shall be planned.
Plot all prospected/ potential locations including
Al-Pro, MSAN, GDI etc. along the expected
feeder cable route.

Decision of Feeder Cable Capacity:


1.Required number of cores 96 96C
2.Required number of cores 97 , 144 144
3.Required number of cores 145 , 288 288
4.Required number of cores 288 288 +
another cable according to the required capacity

Preparation of
CORE ASSIGNMENT
DIAGRAM

Decision of Network
Configuration:
1.Ring
2.Star/Bus

END

CopyrightFujikura Ltd./Y.N

Page 19

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY

Lokasi BB
ODC-288
(193 240)

STO ABC

Lokasi EE
ODC-288
(97 144)

CAD (72)
(01 72)
(288)

01 - 24
(48)

25 - 48
49 - 72

LEGEND:

(96)

CAD
(73 96)

73 - 96

: Joint Closure

97 - 120
121 - 144
145 - 168

: Fusion Splicing

169 - 192
193 - 216
(48)

(XX)

217 - 240
(24)

241 - 264

(24)

: Cable (Core)

265 - 288
(48)
Lokasi AA
ODC-288
(241 288)

Lokasi CC
ODC-144
(169 192)

SKEMA KABEL FEEDER


(Reference for Main Information)

CAD (24)
(73 96)

(193 240)
(48)

STO ABC
(01 288)
(288)
TC-OF-SM-144 (2)
Lokasi AA
ODC-288
(241 288)

CopyrightFujikura Ltd./Y.N

Lokasi BB
ODC-288
(193 240)

(01 240)
(288)
(241 288)
(48)

Lokasi DD
ODC-144
(145 168)

CAD (72)
(01 72)

(97 144)
(01 72)

(01 192)
(288)
(145 192)
(48)
(169 192)
(24)

Page 20

Lokasi EE
ODC-288
(97 144)

(48)

(96)
(145 168)
(24)
Lokasi CC
ODC-144
(169 192)

Lokasi DD
ODC-144
(145 168)

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.5.2 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (2): RING TOPOLOGY
STO ABC

Lokasi CC
ODC-288
(193 240)

Lokasi AA
ODC-144
(265 288)
(48)

CAD
(01 48)

01
25
49
73
97
121
145
169
193
217
241
265

(96)

24
48
72
96
120
144
168
192
216
240
264
288

(96)
Lokasi DD
ODC-288
(145 192)

(48)
Lokasi BB
ODC-144
(241 264)

Lokasi FF
ODC-144
(97 120)
(48)

CAD
(01 48)

265
241
217
193
169
145
121
97
73
49
25
01

288
264
240
216
192
168
144
120
96
72
48
24
(48)

(96)

Lokasi EE
ODC-144
(121 144)

Lokasi GG
ODC-288
(49 96)
Lokasi AA
ODC-288
(241 288)

SKEMA KABEL FEEDER


(Reference for Main Information)
STO ABC

TC-OF-SM-144 (4)

CopyrightFujikura Ltd./Y.N

Lokasi CC
ODC-288
(193 240)

(01 288)
Lokasi BB
ODC-144
(241 264)

(01 288)
Lokasi GG
ODC-288
(49 96)

Lokasi DD
ODC-288
(145 192)

Lokasi FF
ODC-144
(97 120)
(01 288)
Lokasi EE
ODC-144
(121 144)

Page 21

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.6

GENERAL CONCEPT FOR FEEDER CABLE DESIGN

1.6.1 ODC SPEC. (Non-HRB Type)


ODC
type

Designator

Splitter
(1:4)

Maximum HP

Feeder
(input Fiber core)

Number of Cable Entry


(Input+Output)

48
(pole)

ODC-C-48 Splitter

Max. 6pcs

6x32=192

Star ; 12C
Ring ; 24C

96
(pedestal)

ODC-C-96 Splitter

Max. 8pcs

8*32=256

Star ; 12C
Ring ; 24C

144
(pedestal)

ODC-C-144 Splitter

Max. 18pcs

18x32=576

Star ; 24C
Ring ; 48C

12

288
(pedestal)

ODC-C-288 Splitter

Max. 36pcs

36x32=1152

Star ; 48C
Ring ; 96C

12

576
(pedestal)

ODC-C-576 Splitter

Max. 72pcs

72x32=2304

Star ; 96C
Ring ; 192C

24

1.6.2 FEEDER CABLE SPEC.


Fiber Count

Number of Tubes

Number of Fiber/Tube

Tube Diameter

Outer Diameter

Bending Radius
(20 x OD)

12C

2.1mm

12.8mm

25.6cm

24C

2.1mm

12.8mm

25.6cm

48C

12

2.5mm

13.9mm

27.8cm

96C

12

2.5mm

15.6mm

31.2cm

144C

12

12

2.5mm

19.1mm

38.2cm

288C

24

12

2.5mm

22.1mm

44.2cm

CopyrightFujikura Ltd./Y.N

Page 22

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

1.6.3

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
HDPE PIPE/HANDHOLE for FEEDER CABLE

In case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken into
consideration:
1) Feeder Cable with the capacity 288-core:
HDPE BIG/SUBDUCT BIG shall be used.
Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
2) Feeder Cable with the capacity 144-core
HDPE 33/40/SUBDUCT shall be used.
Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.
3) Feeder Cable with the capacity 96-core or less
HDPE 33/40/SUBDUCT shall be used.
Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations

1.6.4

HANDHOLE for ODC

At ODC location, HANDHOLE shall be installed:


1) Type HH-1 (L=1700 x W=1250 x D=1300):
Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the location
where slack is located for future jointing.
2) Type HH-2 (L=1200 x W=600 x D=1300):
Where Handhole shall be located on the carriage way.
3) Type HH-80 (L=800 x W=800 x D=800):
Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and where
no jointing closure will be located.
CopyrightFujikura Ltd./Y.N

Page 23

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
1.6.5

PASS THROUGH CLOSURE for FEEDER CABLE

Through Cable
Type

Model No. (3M)

48core

2179CS

Type 1 : 24core tray (1)


Size ; 447mm x 175mm x 107mm

96core, 144core

Type 2 : 24core tray (1)


Type 3 : 24core tray (2)

2179C

Size ; 557mm x 215mm x 119mm


288core

Type 4 : 24core tray (2)


Type 5 : 24core tray (4)

2178LS

Size ; 557mm x 216mm x 203mm


Option: 24core tray , Re-entry kit
Consultation shall be necessary in case when the other optional items are required.

CopyrightFujikura Ltd./Y.N

Page 24

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.

DISTRIBUTION CABLE DESIGN


Maximum Usage of Distribution Cable shall be 80% of the cable capacity:
Maximum No. of ODP:
No. of Spare Core (CADANGAN)
1) 8-Core Cable: 6 (Only for Branch Section)
2 CORE CAD.
2) 12-Core Cable: 10
2 CORE CAD.
3) 24-Core Cable: 20
4 CORE CAD.

2.1

GOOGLE MAP
1) ODC (Name/Capacity)
2) Distribution Cable Route
3) Location of ODP

2.2

SKEMA KABEL DISTRIBUSI


Purpose: Information required for the Distribution Cable Work
1) ODC

Code STO
ODC No. FA, FB, .......

ODC-XXX-FA-288
ODC Capacity

Code ODC

CopyrightFujikura Ltd./Y.N

Page 25

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2) DISTRIBUTION CABLE
Code STO

Label Feeder (Feeder No., Segment No.)


Distribution No.

Code Distribution Cable

Segment No.
Branch-Segment No.
Core No. In Cable

DSXXX-FE 01-01-01/01-01-01 (01-24)


DC-OF-SM-24SC-xxM
Cable Length in meter
Type of Cable
Duct Cable: DC-OF-SM
Aerial Cable: AC-OF-SM

CopyrightFujikura Ltd./Y.N

Designation for Easy to Split Cable


No. Of Cores

Page 26

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3) ODP
ODP No.
Note: 1. Continuous number starting from D01:
example: 10 ODP on D01, ODP on D02 shall be
started from No.11.
2. ODP No. shall be given from the far most ODP
from ODC location.

Distribution Cable No.

Number of Splitter 1:8


1: ODC-8
2: ODC-16

ODC No.

FA/D01/xx/yy
(xx)
No.

Core No. to be terminated at ODP


e.g. from 01 to 24
The largest No. of care shall be allocated to the nearest
ODP from ODC.

No.
House No. in front of
ODP Location

Coordinates Lokasi ODP


Note: Grounding shall be placed at the last ODP for each distribution cable.

CopyrightFujikura Ltd./Y.N

Page 27

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK
2.3.1
1)

CASE-1: UNDERGROUND/DUCT CABLE


Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.

SKEMA KABEL DISTRIBUSI

ODC-F+-144
xx PS 1:4 (yyHP)

N ++++...
E +++.......

N ++++...
E +++.......

DSABC-FE-01-01/01-02 (01-10)

DSABC-FE-01-01/01-01 (01-12)
DC-OF-SM-12-SC +..m

17

F+/D01/01/02
(03-04)
N ++++...
E +++.......

N ++++...
E +++.......

DSABC-FE-01-01/01-03 (01-09)
DC-OF-SM-12-SC +..m

DC-OF-SM-12-SC +..m

31

F+/D01/05/01
(09)
ODP-PW-BR

F+/D01/06/01
(10)

F+/D01/07/02
(11-12)

N ++++...
E +++.......

16

10

JL. +++++++..

DSABC-FE-01-01/01-xx (01-05)
DC-OF-SM-12-SC +..m

CAD
(01-02)

DSABC-FE-01-01/01-03-01 (08)
DC-OF-SM-8-SC +..m

F+/D01/04/01
(08)
N ++++...
E +++.......

2)

PETA LOKASI KABEL DISTRIBUSI


F+/D01/07/02

F+/D01/06/01

DD-BM-1 +..m

F+/D01/05/01
ODP-PW-BR DD-BM-1 +..m

DD-BM-HDPE-1 +..m

F+/D01/01/02
31

DD-BM-HDPE-1 +..m

ODC-F+-144
xx PS 1:4
(yyHP)

DD-BM-HDPE-1 +..m

CopyrightFujikura Ltd./Y.N

DD-BM-HDPE-1 +..m

10

11

13

12

14

15

16

DD-BM-1 +..m
JL. +++++++..

17

29

30

DD-BM-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-1 +..m

HH-2

DD-BM-HDPE-1 +..m

32

DD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

DD-BM-HDPE-1 +..m

F+/D01/04/01

Page 28

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3) CORE ASSIGNMENT DIAGRAM (For CASE-1)
STO

ABC

NAMA LOKASI

FEEDER SEGMENT
OTB
Port No.

49

ODC
PORT No.

SPLITTER 1:4
No.
Port

Cluster AA (ODC-F+-144)

51

12-CORE

CAPACITY

10

10

11

11

12

12

CAD

8-C

CopyrightFujikura Ltd./Y.N

D-01

DISTRIBUTION SEGMENT
ODC TRAY
CORE
No.
No.
PORT No.

50

DISTRIBUTION
CABLE No.

Page 29

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.3.2
1)

CASE-2: AERIAL CABLE


Note:
At the BRANCHING, the core
assignment and the ODP No. shall be
in accordance with the rule below.

SKEMA KABEL DISTRIBUSI

ODC-F+-144
xx PS 1:4 (yyHP)

31

F+/D01/01/01
(05)
N ++++...
E +++.......

N ++++...
E +++.......

N ++++...
E +++.......

N ++++...
E +++.......

17

F+/D01/06/01
(10)
ODP-PW-BR

F+/D01/07/01
(11)

F+/D01/08/01
(12)

N ++++...
E +++.......

16

10

DSABC-FE-01-01/01-01 (01-12)

DSABC-FE-01-01/01-02 (01-11)

DSABC-FE-01-01/01-03 (01-10)

DSABC-FE-01-01/01-xx (01-05)

AC-OF-SM-12-SC +..m

AC-OF-SM-12-SC +..m

AC-OF-SM-12-SC +..m

AC-OF-SM-12-SC +..m

JL. +++++++..

CAD
(01-04)

DSABC-FE-01-01/01-03-01 (09)
AC-OF-SM-8-SC +..m

F+/D01/05/01
(09)
N ++++...
E +++.......

2)

PETA LOKASI KABEL DISTRIBUSI


F+/D01/08/02

F+/D01/06/01
ODP-PW-BR

F+/D01/07/01

F+/D01/01/01
31

1
BC-PP 3m

30m

30m

10

11

45m

12

45m

ODC-F+-144
xx PS 1:4
(yyHP)
HH-2

14

15

16

45m

17

30

+.m

32

25m

45m

JL. +++++++..

13

29

F+/D01/05/01

LEGEND
: New Pole
ODP Aerial
(1 x 1:8 Splitter)

: Existing Pole

CopyrightFujikura Ltd./Y.N

Page 30

Branching ODP
(1 x 1:8 Splitter)

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3) CORE ASSIGNMENT DIAGRAM (For CASE-2)

STO

ABC

FEEDER SEGMENT
OTB
ODC
Port No.
PORT No.

49

NAMA LOKASI

SPLITTER 1:4
No.
Port

DISTRIBUTION SEGMENT
ODC TRAY
CORE No.
No.
PORT No.

10

10

11

11

12

12

50

51

CAPACITY

D-01

12-CORE

12-C

12-C

CAD

8-C

ODP No.

CopyrightFujikura Ltd./Y.N

DISTRIBUTION
CABLE No.

Cluster AA (ODC-F+-144)

Page 31

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.4 BRANCHING ODP
Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but
independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP).
Branching ODP:
1)Branching ODP is applicable for both underground as well as aerial distribution cable design.
2)Type of ODP is Cabinet type to be mounted on: WALL, POLE and PEDESTAL.
3)The cable to be branched from the main cable shall be of 8-Core.
4)The number of ODP on branched cable shall be less than 8.
5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter.

1)

Underground Cable
(Pedestal/Wall Mount)

Branching ODP
(1 x 1:8 Splitter)
Designator:
ODP-PL-BR

2)

Aerial Cable
(Pole Mount)
Branching Cable
(SCPT-8-core)

ODP Pedestal/Wall
Capacity: 8 or 16

ODP Aerial
Capacity: 8

ODP Aerial
Capacity: 8

ODP Pedestal/Wall
Capacity: 8 or 16

Branching Cable
(SCPT-8-core)

Main Cable
(SSW-8/12/24-core)

Branching ODP
(1 x 1:8 Splitter)
Designator:
ODP-P/W-BR

Main Cable
(SCPT-8/12/24-core)

CopyrightFujikura Ltd./Y.N

Page 32

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.5 DUCT USAGE FOR DISTRIBUTION NETWORK &
DROP-CORE INSTALLATION (UNDERGROUND)

ODC ODP/ ODP ODP


1)DD-BM-HDPE
2)BC-TR-1.5 + DD-HDPE
HH-PIT-40

HH-PIT-40 - Premises
1) BC-TR-0.4 + PP-OF-OUT(PVC )

HH-PIT-40

ODP (HH-PIT-60) HH-PIT-40/


HH-PIT-40 HH-PIT-40
1) BC-TR-0.6 + DC-SD-1 Big

HH-PIT-60

CopyrightFujikura Ltd./Y.N

Page 33

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN


General Preparation for the Distribution Cable Design:
Prior to plotting ODP on the map, ODP Boundary (Max. 8 or 16HP) shall be designated so
that the number of ODP and its location can be planned efficiently.

3.1

DUCT/BURIED SECTION
1)

Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core <100 meter maka
penempatan ODP diletakkan di ujung jalan masuk Blok Perumahan, Gambar Terlampir:

1)

When you find a blind alley which need drop core cable less than 100 m, the ODP should be placed at
the entrance of the alley. Please see the illustration below.

CopyrightFujikura Ltd./Y.N

Page 34

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter maka
diperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke
ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir :
2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the
main distribution cable according to the quantity of HP. Please see the illustration below.

CopyrightFujikura Ltd./Y.N

Page 35

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukan
secara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir :
3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be
adjusted according to the HP. Please see the illustration below.

CopyrightFujikura Ltd./Y.N

Page 36

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

3.2

AERIAL SECTION

1)

Sample Design based on Duct Cable Design Standard


=> (Some consideration due to particularity of the aerial cable shall be required.)
C-CLAMP x 2

Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the number
of ODP and its location can be planned efficiently.

SSW CABLE

ODP-BR
Detail for
Riser Part

AC-OF-SM-8-SC

Road width
less than 6m

AC-OF-SM-12-SC

30m
6.5m

45m
6.5m

45m

45m

Road width
more than 6m

40m
11m

45m

Detail for Riser Part

LEGEND

45m
ODP-BR

45m

: ODC

25m
6.5m
45m
45m

CopyrightFujikura Ltd./Y.N

AC-OF-SM-8-SC

45m
45m

Note: Location where special


consideration is required due
to a particularity of the aerial
cable installation

Cable part shall be


protected with Spiral
for outdoor use (Black
color)

25m

AC-OF-SM-12-SC
45m
35m

Page 37

: ODP
1) ODP-SSW-8
2) ODP-BR
:

HH-2/HH-80

New Pole 7m/9m

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2)

Sample Design based on Particularity for Aerial Cable

Note: Location where special


consideration is taken due to
a particularity of the aerial
cable installation

Some particular consideration required for


Aerial Cable Design
1.

40m
25m
Road width
less than 6m

30m
6.5m
30m

45m

15m

40m
45m

6.5m

2.

10m
45m

3.

Road width
more than 6m
11m

40m

30m
45m

35m

45m

45m

45m

45m

Additional pole(s) may be required for the


drop cable installation. (Actual installation
of additional poles shall be decided in
accordance with contract with the
developper/owner)
Road width less than 6m can be crossed by
the drop cable as far as the road traffic will
not be disturbed otherwise new pole shall
be installed.
Location of ODP shall be decided so that:
1) Drop cable can be installed along SSW
cable.
2) Drop cable can be installed indipendently
for one (1) span (2 spans at maximum)

25m
35m

35m

6.5m
45m

Detail "Drop-A"
Detail "Drop-B"

Detail "Drop-C"

25m

45m

25m
LEGEND for Additional Item

CopyrightFujikura Ltd./Y.N

Additional Pole for


Drop Core

Drop Core Run

45m
35m

Page 38

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3)

Details of SSW Installation

A. Details of Riser Part

B. ODP-SSW Location
B-2. With LINE GUARD

B-1. With C-CLAMP

C-CLAMP x 2

25cm

SSW CABLE

30cm
ODP-SSW-8

Cable part shall


be protected with
Spiral for outdoor
use (Black color)

< 120

Line Guard

ODP-SSW-8

L= 51cm
SUSPENSION CLAMP

LEGEND
:

SSW Cable (Japan)

10cm

: C-Clamp (Japan)
C. Cable Allignment
At the cable laying, turns in
the cable shall be released
by turning the cable winding
while making the 8-figure.

D. C-LAMP

As far as it is practical, the


cable shall be installed so
that the suspension wire is
always above the cable part.

150mm remove sheath

50mm

Suspension Wire

E. Line Guard Installation


LINE GUARD shall be installed where:
1. One (1) in every three (3) poles in the
straight line.
2. At the pole beside the ODP-SSW is
installed except the location where CCLAMP is installed.

Caution:
Bend

Cable Part

CopyrightFujikura Ltd./Y.N

Page 39

LINE GUARD shall be fixed and the Suspension


Wire at C-CLAMP shall be bent ONLY after all
ODP-SSW installation have been completed
and the cable allignment has been confirmed
so that no turn is contained in the cable span.
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
4)

Details of Drop-Core Solution


LEGEND
: S-Clamp (Japan)
: D-Clamp (Japan)
: BW-Clamp (Local)

Detail "Drop-C"

Detail "Drop-A"
Wire Grip 3/8"
with double nut

Details of "Home Connect"


FUSE-CONNECT

Messenger wire from drop cable to pole or


1.2mm galvanized steel wire with sheath coating

ODP-SSW-8

ISC-UPC-FD
Drop Cable
(Aerial)
HC-OF-SM-2D

ODP-PL/PW8/16

Drop Cable
(Underground)
GC-OF-SM-2D

ROSETTE
RS-IN-SC-1P/
TC-MK-SC-1P

Detail "Drop-B"

CopyrightFujikura Ltd./Y.N

Page 40

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

4.

CABLE RACK/OTB RACK IN STO BUILDING


CABLE RACK

Note:

19 RACK H=2200
Max. 5 x TC-OF-SM-144

MDF
ROOM

FEEDER
CABLE

OTB ROOM/
TRANSMISSION
ROOM

1.

The cable routing in the STO building shall be


measured so as to estimate the cable length
from the duct entrance at the Cable Chamber
until the OTB.

2.

In case when the new rack shall be provided, the


rack to be installed shall be of same type and
the same color with the existing one.

3.

In the decision of the location of 19 rack


installation, well coordination with DBB, Telkom
Area and/or WASPANG is required.

4.

When the location of new 19 Rack installation


is fixed, the designated location on the floor
shall be clearly marked with an adhesive tape
and a permanent marker as:

CABLE
CHAMBER

FTTH OSP
JF DJAFa
5.

The maximum number of unit of TC-OF-SM-144


to be accommodated in the 19 Rack with
Height of 2.20m shall be FIVE (5).

STO BUILDING

CopyrightFujikura Ltd./Y.N

Page 41

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

5.

HIGH-RISE BUILDING (HRB) DESIGN

5.1

MATERIAL FOR HRB SOLUTION

No.

Designator
1.

Application

No. of Splitter
(Max.)

Number of Port
In

Out

Home Pass
Accommodated (80%)

Total

ODC for HRB/MDU

(Approx.)

1.1

ODC-HRB-180 (*)

Cabinet/ Wall

1:4 x 36

36

144

180

900

1.2

ODC-HRB-240 (*)

Cabinet

1:4 x 48

48

192

240

1200

1.3

ODC-HRB-420 (*)

Cabinet

1:4 x 84

84

336

420

2200

1.4

ODC-HRB-RACK-120 (**)

19" Rack Mount

1:4 x 24

24

96

120

600

1.5

ODC-HRB-RACK-240 (**)

19" Rack Mount

1:4 x 48

48

192

240

1200

1.6

ODC-HRB-RACK-480 (**)

19" Rack Mount

1:4 x 96

96

384

480

2500

2.

ODP for HRB/MDU

(Installed)

2.1

ODP-HRB-16 (*)

Wall Mount

2.2

ODP-HRB-32 (*)

Wall Mount

3.
3.1
3.2
4.

(Max.)

1:8 x 1

1:8 x 2

16

16

1:8 x 3

24

24

1:8 x 4

32

32

16
32

2-C Low Friction Indoor Cable


IC-OF-SM-1D
IC-OF-SM-2D

1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE


Distribution/ Drop-core

ROSETTE

2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE


1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare
SC Adapter

4.1

RS-IN-SC-1P

4.2

RS-IN-SC-2P

To be discussed when necessary (***)

4.3

RS-IN-SC-4P

To be discussed when necessary (***)

4.4

TC-MK-SC-1P

4.5

TC-MK-SC-2P

To be discussed when necessary (***)

4.6

TC-MK-SC-4P

To be discussed when necessary (***)

Indoor Rosette

Indoor Rosette (Buried in


wall)

Note (*): New Item (Specifications have been accepted by TELKOM)


(**): New Item (Specifications shall be subject to concurrence by TELKOM)
(***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer
CopyrightFujikura Ltd./Y.N

Page 42

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
5.2

DESIGN CONCEPT FOR HRB SOLUTION


ODPHRB

DESIGN CONCEPT FOR HRB

ODP:
1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter)
Size: H=330 x W=260 x D=130
2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter)
Size: H=412 x W=312 x D=140

1-Core Low Friction Indoor Cable for


1x 1:8 Splitter with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends

1.

Rosette: TC-MK-SC-xP
(1-Port/2-Port/4-Port)

ODPHRB

2-Core Low Friction Indoor Cable


with Field Installable SC Connector
(Fuse-connect) x 1pc at both ends

Cable Tray/Shaft/Ladder

ODC-HRB1) 180
2) 240
3) 420

Feeder Cable:
1) For ODC-HRB-180: 24/48C
2) For ODC-HRB-240: 48C
3) For ODC-HRB-480: 96C

ODC shall be selected among all types


according to the site situation as well as
number of Home Pass of the target
building.
2.
ODP shall be selected among three (3)
types according to the number of Home
Pass and the Floor Layout.
3.
2-Core Low Friction Indoor Cable shall
be used between ODC and ODP.
4.
One (1) Low Friction Indoor Cable shall
be connected ODC Port with one (1) 1:8
Splitter of ODP i.e.:
1) ODP-HRB-16: One (1) or two (2) Low
Friction Indoor Cable:
a. 1 x 1:8 Splitter: 1 Low Friction Cable
b. 2 x 1:8 Splitter: 2 Low Friction Cables
2) ODP-HRB-32: Three (3) or four (4) Low
Friction Indoor Cables:
a. 3 x 1:8 Splitter: 3 Low Friction Cables
b. 4 x 1:8 Splitter: 4 Low Friction Cables

4) For ODC-HRB-RACK-120: 24C


5) For ODC-HRB-RACK-240: 48C
6) For ODC-HRB-RACK-480: 96C

ODC-HRB-RACK1) 120
2) 240
3) 480
CopyrightFujikura Ltd./Y.N

Page 43

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
5.3

Type of ODC for High-Rise-Building


2) RACK MOUNT TYPE
(To be mounted in the Closed Rack H=1.20m)

1) CABINET TYPE
W=555
D=310

H= 770

H= 275

D=302.3
W=428

ODC-HRB-180
Application: Wall/Floor

ODC-HRB-RACK-120
Application: 19" Rack

W=750

D=302.3

D=360
H= 890

H= 1450

D=302.3

H= 445

W=428

W=428
ODC-HRB-RACK-240
Application: 19" Rack

ODC-HRB-240/420
Application: Floor
CopyrightFujikura Ltd./Y.N

Page 44

ODC-HRB-RACK-480
Application: 19" Rack

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
5.4

Example of Cable Tray/Trunking


1) HORIZONTAL RUN

2) VERTICAL RUN

(a) On the Cable Tray

Cable Trunking
ODPHRB
Cable Tray

(b) Direct Attachment to the Building Wall


Elbow (Flat Angle)

T-Joint
Cable Trunking

CopyrightFujikura Ltd./Y.N

Page 45

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
5.5

SAMPLE DESIGN: SKEMA DISTRIBUSI


F//P03/2/1
ODP-HRB-16
(Note: Not "8")

F//P01-02/1/2
ODP-HRB-16

F//P04-05/3/2
ODP-HRB-16

Floor-xx
2 IC-OF-SM-1D__m

1 IC-LF-OF-SM-1D __m

2 IC-OF-SM-1D __m

x IC-OF-SM-1D __m

x IC-LF-OF-SM-1D __m

x IC-OF-SM-1D __m

2: No. of Indoor Cable to be installed and


terminated to ODP
__m: Cable Length from ODC to ODP

Floor-yy

Floor-zz
x IC-OF-SM-1D __m

x IC-LF-OF-SM-1D __m

Note:
Type of ODP-HRB is 2:
1. ODP-HRB-16: No. of 1:8
Splitter= 1 or 2
2. ODP-HRB-32: No. of 1:8
Splitter= 3 or 4

x IC-OF-SM-1D __m

Tower A/
Shaft No.1
ODC ABC BUILDING
F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)
S 6 +++++
E 106 +++...

Specify "Tower" and/or


"Shaft" according to the
Building Layout.

Descriptions for ODP


Descriptions for ODC

1. F+/

P-03/

2/

1
No. of Splitter 1:8

ODC
XXX (Name of Building)

2. F...

/STO

ODP No.

/HRB-(RACK)-xxx

Code STO
ODC No.

"HRB"-"Capacity"
180
240
420

ODC No.
2. ODP-HRB-xx

3. xx PS 1:4 (xxx HP)


No. of Splitter

ODC Port No.


Each No. to be given for Each 1-Core
Indoor Cable

Type of ODP: ODP-HRB-16, 32 (See Note above.)


No. of Home Pass

4. Coordinates
CopyrightFujikura Ltd./Y.N

Page 46

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
SAMPLE DESIGN: PETA LOKASI DISTRIBUSI

5.6
1)

PETA LOKASI KABEL DISTRIBUSI (Vertical View)

Tower A

Cable Shaft No.2

Cable Shaft No.1

F//P01-02/1/2
ODP-HRB-16

F//P03/2/1
ODP-HRB-16
Note: Not "8"

F//P04-05/3/2
ODP-HRB-16

LEGEND
: ODC-HRB

: ODP-HRB
: Cable Tray/Trunking
(New)
: Cable Tray/Trunking
(Existing)

ODC ABC BUILDING


F.../STO/HRB-xxx
xx PS 1:4 (xxx HP)

CopyrightFujikura Ltd./Y.N

: Rosette (1-Port)

: Rosette (2-Port)

Cable Tray/Trunking to be installed


e.g. Cable Tray W=100mm x 35m

Page 47

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2)

PETA LOKASI DROP-CORE (Floor Plan)


F//P03/2/1
ODP-HRB-16
Note: Not "8"

F//P01-02/1/2
ODP-HRB-16

3
1

F//P04-05/3/2
ODP-HRB-16

10

LIFT
1

1
13

12

14

15

16

17

18

19

20

26

25

24

23

22

21

38

39

1
11
29

28

CopyrightFujikura Ltd./Y.N

31

32

30

27
1

1
34

33

Page 48

35

36

37

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
3)

LIST OF PORT MANAGEMENT & DROP-CORE LENGTH


Table-1: List of Port Management
ODC Port
No.

Distribution
Cable No.

ODP
Unit No.
No./Floor

D01

Splitter No.

Port

Drop Cable
Length (m)

30.0

18.0

10.0

25

55.0

26

50.0

27

45.0

28

40.0

29

35.0

11

12
30
31
2

D02

32
33
34
35
6
7
8

CopyrightFujikura Ltd./Y.N

Page 49

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

CopyrightFujikura Ltd./Y.N

Page 50

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.1

PONDASI ODC-C-144 Splitter

ODC Foundation: Top View


(Not to scale/ Unit: mm)
B

660

(Expansion Bolt: M8 x 150)

170

440

140

1035mm

135

Drill:14mm/ d= 75 85mm

150
463

150

360

440

150

555mm

135

150

170

98.5

98.5

463
660

310mm

52.5

52.5

555

65

310

115

98.5

463

98.5

65

115

170

Approx. 30cm
ODC Foundation
(B-B Side)
G.L.

0
- 200
Handhole
Type:HH-80

75 85mm

75 85mm

Drill:14mm/ d= 75 85mm

Drill:14mm/ d= 75 85mm
(Expansion Bolt: M8 x 150)

500

Special Attention:
Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never be
located in the ODC Foundation.

(Expansion Bolt: M8 x 150)

G.L

5 x HDPE 33/40

- 1000
- 1500

- 600

Handhole
Type:HH2

R > 500mm
Approx.30cm or less

G.L
1100

W=600
(HH-2)

600

W=800
(HH-80)

Conduit Connection
(Not to scale/ Unit)
360

150

150

150

660
ODC Foundation: A-A
(Not to scale/ Unit: mm)

CopyrightFujikura Ltd./Y.N

140

150

440
ODC Foundation: B-B
(Not to scale/ Unit: mm)

Page 51

Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru
2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.2

PONDASI ODC-C-288 Splitter

ODC Foundation: Top View


(Not to scale/ Unit: mm)
B
850
165

320mm

120

150

200

140

440

1450mm

120

(Expansion Bolt: M12 x 150)

A
200

165

520

Drill:18mm/ d= 60 80mm

150

ODC Mount and


Location of Anchor
Bolt
612

440

750mm

119

612

119

850
50

119

120

119

612

60

320

60

50

750

120

200

Special Attention:
Cable Slack shall be placed only in
HANDHOLE/HH-PIT and never be
located in the ODC Foundation.

Approx. 30cm

ODC Foundation
(B-B Side)

G.L.

- 200

60 80mm
500

60 80mm

Handhole
Type:HH-80

Drill:18mm/ d= 60 80mm
Drill:18mm/ d= 60 80mm
(Expansion Bolt: M12 x 150)

(Expansion Bolt: M12 x 150)


G.L

G.L

- 1000

- 1500

1100

- 600

Handhole
Type:HH2

5 x HDPE 33/40
R > 500mm
Approx.30cm or less

600

W=600
(HH-2)
W=800
(HH-80)

Conduit Connection
(Not to scale/ Unit)
520

165

165

150

850

140

150

440

ODC Foundation: A-A


(Not to scale/ Unit: mm)

CopyrightFujikura Ltd./Y.N

ODC Foundation: B-B


(Not to scale/ Unit: mm)

Page 52

Keterangan:
Pondasi dan lantai kerja berlapis keramik.
1. Pondasi: Keramik 20 x 20, warna biru
2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.3

PONDASI ODP PEDESTAL & HH-PIT-60


500
300

100

100
300

100

Sub-duct BIG

Distance in accordance with


the site situation.
Jaak sesuai kondisi lapangan.

300

200

TELKOM

150

700

500

150

100

100

500

PVC 4"

Distribution Cable Installation


shall cautiously be carried out
so that the Bending Radius of
20cm shall be secured.

100

Cable Installation Method between HH-PIT-60 and ODP


400

150
100

150

700

Distance in accordance with


the site situation.
Jaak sesuai kondisi lapangan.

100

900

100

500
300

Note H: Height above ground


shall be minimum 10cm. Actual
height shall be in accordance
with the site condition.

100

700

600-H

450

150

150

900

600

150

LARGE RADIUS ELBOW


PVC 4"
(WAVIN D-LL 4" or Equivalent)

150

PVC 4" for


Distribution Cable
L=300

100

150

PVC 4" for


Drop Cable
L=300

150

Sub-duct BIG
PVC 4"
150
600

150

400

PVC 4" L= 650

600

200 150

80

150

100

500

220

100

150

700

900

CopyrightFujikura Ltd./Y.N

Page 53

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)

6.4

PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1


(288-C Loose Tube Cable / 3M Type 2178LS)

1300

250

1300

+- 90cm

1350
A

625

288-C cable
R= 44.2mm
557mm
+- 150cm

450

625

900

450

625

T
E
L
K
O
M

150

150

TELKOM

TELKOM

TELKOM

950

T
E
L
K
O
M

250

T
E
L
K
O
M

150 150 150

1550

150

3 x 600 = 1800

250

625

100 200

200 200

200 200

200

200

200 200

1000
1250

1700
100

2000
B
100

600

200 200 200

200 200

200

1550
1350

100

200

200

100
200

950

200

200 200

100

600

600

BESI 70 x 50 x 3
Hole 20mm

12mm x 125mm

12mm x 125mm

L=300

1650

1300

10mm x 125mm

10mm x 125mm
10mm x
125mm
1
5
1
0
5
0

150

150 150

10mm x 125mm

150

1700
2000

150

150

PVC 4" x 4
L= 300

1
5
0

BETON: 225kg/cm
150

POT B - B

POT A - A

CopyrightFujikura Ltd./Y.N

1250
1550

1
5
0

Page 54

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300)

6.5

B
PVC 4" x 4
L= 300

T
E
L
K
O
M

A
700

150 150

T
E
L
K
O
M

150

900

300

150

2 x 650 = 1300

100

225

200

225

225

200

225

100

1500
B
100

650
200

225

225

200

100

225

150

100

400

150

200

225

900
700

100

650

BESI 70 x 50 x 3
Hole
20mm
10mm x 125mm

L=300

150

PVC 4" x 4
L= 300

150

150

150

150

150

150

10mm x 125mm

1650

1300

10mm x 125mm

150

CopyrightFujikura Ltd./Y.N

1200

150

150

600

1500

900

POT A - A

POT B - B

Page 55

150

BETON: 225kg/cm

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

6.6

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
HH-80: Dimensi Dalam (P=800 x L=800 x T=800)
B

100

1100

T
E
L
K
O
M

1100

600

900

T
E
L
K
O
M

100

150

1100

150

PVC 4" x 4
L= 300

125 200 125 125 200 125


100

450

450

100

1100
B
1100

1100
100

150

Hole 20mm
10mm x 125mm
PVC 4" x 4
L= 300

150

150 150

800

1150

150

150

150

150 150

800

10mm x 125mm

1150

10mm x 125mm

150
800

600

BESI 70 x 50 x 3

L=300

150

100

900
150

200

450
450
125 200 125 125 200 125

200

100

100

150

800
1100

1100

150

BETON: 225kg/cm

POT B - B
POT A - A

CopyrightFujikura Ltd./Y.N

Page 56

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION OF ODP WALL (1)

6.7

Approx.
5cm
Gap between steel pipe (
2") and ODP (Wall Mount)
shall be less than 10cm

Gap between steel pipe (


2") and ODP (Wall Mount)
shall be less than 10cm

Identification Marking
(White color) shall be
applied on the cable of
"Up-stream/ODC" side.

A (See
detail.)
Approx.
10cm

Approx.
10cm

In case Gap between


steel pipe ( 2") and ODP
(Wall Mount) is more than
5cm, cables shall be
protected with spiral or
flexible pipe (Black color)

HDPE Pipe 33/40

Clamps shall be attached Approx.


@ < 1.0m

Details "A"

HDPE 33/40 shall be


installed until the level with
Galvanized Steel Pipe..

G.L.

30cm

20cm

10cm

B (See detail.)

Approx.
10cm

Approx.
10cm

G.L.

10c
m

30cm

30cm

10cm

Galvanized Steel Pipe (2")


and Clamps shall be painted
with the same color with the
wall.

Clamps shall be attached


Approx. @ < 1.0m

Approx. 2.20m

2" Galvanized Steel Pipe

30cm

30cm

Details "B"

CopyrightFujikura Ltd./Y.N

Page 57

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION OF ODP WALL (2)

6.7

(In case pipe shall be buried in the wall)


Flex. Pipe
Drop Cable

Approx. 100
Approx.
200

Approx.
200
Approx.
100

Flex-pipe
PVC Simple
R300
Socket for OD
25mm Pipe

Pipes shall be buried in the wall.


Pipe space shall be filled with
concrete after ODP installation.

Flex-pipe R300
PVC/High-Impact
Conduit OD 25mm
Pipes shall be buried in the wall.
Pipe space shall be filled with
concrete after ODP installation.

Flex-pipe
R300

Appro
x. 100
Flex-pipe
R300
HH PIT-60

Approx. 100
150

HH PIT-60

150

Flex-pipe
R300

50
100

2 x PVC 50
(L=200)

OD=25mm
Steel flexible inside

PVC/High-Impact
Conduit OD 25mm

Note:
In case when pipes shall be buried in the building wall due to the
requirement by the developer, the following points shall be taken into
account for the installation.
1. HH-PIT-60 shall be installed in front of ODP location.
2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of
conduit.
3. Bending Radius of Flexible Pipe shall be more than 300mm.
4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of
conduit.
5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.
6. Pipe space of wall shall be filled with concrete after installation of ODP.
(ODP termination work shall be done prior to the pipe fixing and concrete
work.)
7. The wall shall be restored to the original condition and painted with the
same color with the original wall.
MOM/BA shall be made (to be signed by the PIC of the developer) for the
confirmation of the requirement.

CopyrightFujikura Ltd./Y.N

Page 58

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.8
6.8.1

FORM FOR CORE ASSIGNMENT


FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)

CopyrightFujikura Ltd./Y.N

Page 59

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.8.2

FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)

CopyrightFujikura Ltd./Y.N

Page 60

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.8.3

FEEDER CABLE (RING TOPOLOGY)

CopyrightFujikura Ltd./Y.N

Page 61

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
6.8.4

DISTRIBUTION CABLE
CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE)

STO
FEEDER SEGMENT
OTB
ODC
Port No.
PORT No.

NAMA LOKASI

SPLITTER 1:4
No.
Port

DISTRIBUTION CABLE No.

D-

CAPACITY

-CORE

DISTRIBUTION SEGMENT
ODC TRAY
CORE No.
No.
PORT No.

10

10

11

11

12

12

13

14

15

16

17

18

19

20

21

10

22

11

23

12

24

ODP No.

CopyrightFujikura Ltd./Y.N

Page 62

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION CHECK SHEET
INSTALLATION CHECK SHEET: ODC-C-144
6.9
6.9.1

Installation Check Sheet

Baut expansion tidak kendur

Tipe Product : ODC-C-144


Tgl. Instalasi
Nama Lokasi
Nama Installer
Category
Items
1. Aksesoris
Cable band (M)
Cable band (L)
* cek sisa aksesoris yang diperlukan
Spiral Tube
untuk instalasi kabel berikutnya dan untuk
Compound
maintenance
Cable tie
Assembly manual
PVC tape
* 2 buah kunci ODC harus sudah
diterima site manager

2. Pondasi ODC

Penggunaan Compound harus rapat (tidak ada celah)


4. Cable clamp

Clamp untuk tension Member tidak kendur


Cable Band tidak Kendur

3. Lubang Kabel Masuk (Feeder & Distribusi)

5. Rute Loose Tube

Tidak ada small bending (diameter > 60)


tidak terjepit dengan tutup tray
Tidak ada small bending (diameter > 60)
tidak terjepit dengan tutup tray

7. Rute Pigtail dalam Tray

Arah Rute (bentuk S)


Tidak ada small bending (diameter > 60)
tidak terjepit dengan tutup tray

6. Rute Fiber didalam Tray

8. Instalasi Splitter modul


9. Rute kabel dari Splitter ke Tray

diperiksa oleh :
(Site manager)

Konektor tercolok dengan benar (sampai bunyi klik)

Arah dan Posisi Splitter harus benar (Input :bawah;


Output :atas)
rute sesuai petunjuk manual
Tidak ada small bending (diameter > 60)
tidak saling tersangkut dan mudah di urai

10. SC connector patching

Catatan

Check
pcs
pcs
pcs
pc
pcs
pc
pc

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 63
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION CHECK SHEET: ODC-C-288
6.9.2

Installation Check Sheet

Baut expansion tidak kendur

Tipe Produk : ODC-C-288


Tgl. Instalasi
Nama Lokasi
Nama Installer
Category
Items
1. Aksesoris
Cable band (M)
Cable band (L)
* cek sisa aksesoris yang diperlukan
Spiral Tube
untuk instalasi kabel berikutnya dan untuk
Compound
maintenance
Cable tie
Assembly manual
PVC tape
* 2 buah kunci ODC harus sudah
diterima site manager

2. Pondasi ODC

4. Cable clamp

Clamp untuk tension Member tidak kendur


Cable Band tidak Kendur

3. Lubang Kabel Masuk (Feeder & Distribusi) Penggunaan Compound harus rapat (tidak ada
celah)

5. Rute Loose Tube

Tidak ada small bending (diameter > 60)


tidak terjepit dengan tutup tray
Tidak ada small bending (diameter > 60)
tidak terjepit dengan tutup tray

7. Rute Pigtail dalam Tray

Arah Rute (bentuk S)


Tidak ada small bending (diameter > 60)
tidak terjepit dengan tutup tray

6. Rute Fiber didalam Tray

8. Instalasi Splitter modul


9. Rute kabel dari Splitter ke Tray

Diperiksa oleh
(Site manager)

Konektor tercolok dengan benar (sampai bunyi klik)

Arah dan Posisi Splitter harus benar (Input : kiri ;


Output : kanan)
rute sesuai petunjuk manual
Tidak ada small bending (diameter > 60)
tidak saling tersangkut dan mudah di urai

10. SC connector patching

Catatan

Check
pcs
pcs
pcs
pc
pcs
pc
pc

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 64
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION CHECK SHEET: ODP-PL/PW-8/16
6.9.3

Product Type : ODP-CA-8/16-WP


Installation Date :
Installation Site :
Installer Name :
Category
1. Accessory

Installation Check sheet

Items
Cable tie
Expansion screw

Clamp untuk Tension member Tidak kendur


Clamp untuk kabel tidak kendur

pemasangan tempat masuk kabel harus rata, tidak miring

Arah : input : kiri ; output : kanan , label terlihat


Posisi Splitter : No1 paling atas
Tidak ada small bending (diameter > 60)
Kabel Tidak terjepit atau tersangkut jika dibuka
Posisi Konektor
ada disebelah kanan,
Baris konektor paling bawah untuk Splitter no.1
tidak ada celah (penggunaan solasi atau grommet
harus dapat menutup celah)

PVC tape

* cek sisa aksesoris yang diperlukan


Drop cable fixing clamp
untuk instalasi kabel berikutnya dan untuk
Buku manual
maintenance
* 1 buah kunci ODP harus sudah
diterima site manager

2. Instalasi Splitter

3. instalasi output Splitter pada panel


Adapter
4. Lubang Tempat kabel masuk

5. clamp Kabel

6. Rute kabel SCPT Pass through

Tidak ada small bending (diameter > 60)


Tidak terjepit dan tersangkut jika ODP dibuka

Diperiksa oleh :
(Site manager)

Tidak ada small bending (diameter > 60)


tidak terjepit dan tersangkut jika ODP dibuka

7. Clamp dan rute SCPT yang di terminasi pastikan penggunaan kabel Ties di tiga titik
Tidak ada small bending (diameter > 60)
tidak terjepit dan tersangkut jika ODP dibuka

8. Rute Fiber setelah Splicing

Catatan

Check
pcs
sets
pcs
pc
pc

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 65
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
INSTALLATION CHECK SHEET: TC-SM-144
6.9.4

Installation Check Sheet

2. Clamp kabel

Clamp untuk Tension member Tidak kendur


Cable Band tidak kendur

Product Type : TC-SM-144


Installation Date :
Installation Site :
Installer Name :
Category
Items
1.Aksesoris
Cable band (M)
Cable band (L)
Plastic Tube
* Cek sisa aksesoris yang diperlukan
Screw and nut
untuk instalasi kabel berikutnya dan untuk
Cable tie
maintenance
Buku Manual
PVC tape

3. Rute kabel Loose tube

Diperiksa oleh
(Site manager)

Rute membentuk huruf S


Tidak ada small bending (diameter > 60)
Tidak Terjepit atau tersangkut jika cover tray dibuka

Tidak ada small bending (diameter > 60)


Tidak terjepit atau tersangkut jika cover tray di buka

Tidak ada small bending (diameter > 60)


kabel Tidak terjepit atau tersangkut jika tray dilepas

4. Rute kabel dalam tray


5. Rute Pigtail pada Tray

Catatan

Check
pcs
pcs
pcs
sets
pcs
pc
pc

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 66
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (1/6)
6.10

NO

A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

DESIGNATOR

34
35
36
37
38
39

33

32

28
29
30
31

27

25
26

24

22
23

AB-OF-SM-2D

OS-SM-12
OS-SM-24
OS-SM-48
OS-SM-96
OS-SM-144
OS-SM-288

OS-SM-6

OS-SM-1 Eks

SC-OF-SM-48
SC-OF-SM-96
SC-OF-SM-144
SC-OF-SM-288

SC-OF-SM-24

AC-OF-SM-12-SC
AC-OF-SM-24-SC

AC-OF-SM-8-SC

DC-OF-SM-12-SC
DC-OF-SM-24-SC

21

40

GC-OF-SM-1D

AB-OF-SM-4D
AB-OF-SM-8D
AB-OF-SM-12D
AB-OF-SM-24D
AB-OF-SM-48D
AB-OF-SM-72D
AB-OF-SM-96D
AB-OF-SM-144D

URAIAN PEKERJAAN

Idem 12 Core
Idem 24 Core
Pengadaan dan pemasangan alat sambung (cabang/
lurus) untuk Fiber Optik kapasitas 12 - 24 core
Idem 12 - 48 core
Idem 12 - 96 core
Idem 12 - 144 core
Idem 12 - 288 core
Penyambungan Kabel Optik Single Mode kap 1 core
dengan cara fusion splice
Penyambungan Kabel Optik Single Mode kap 6 core
dengan cara fusion splice
Idem kap 12 core
Idem kap 24 core
Idem kap 48 core
Idem kap 96 core
Idem kap 144 core
Idem kap 288 core
Pengadaan dan pemasangan Air Blown Cable Optik,
Single Mode 2 core, G 652 D (termasuk perijinan
PEMDA, PU, Warga)
Idem 4 core
Idem 8 core
Idem 12 core
Idem 24 core
Idem 48 core
Idem 72 core
Idem 96 core
Idem 144 core
Pengadaan dan pemasangan Drop Cable FO Duct
/under ground 1 Core Single Mode, G.657
idem 2 core
Pengadaan dan pemasangan Drop Cable FO atas
tanah /aerial 1 Core Single Mode, G.657
idem 2 core
Pengadaan dan pemasangan Indoor Cable FO Single
Mode 1 core, G.657
Idem 2 core

Pengadaan dan pemasangan Kabel Udara Fiber


Optik Single Mode 8 core G 652 D, "Easy to split"
(termasuk perijinan PEMDA, PU, Warga)

KABEL & PENYAMBUNGAN


Pengadaan dan pemasangan Kabel Duct Fiber Optik
DC-OF-SM-12D
Single Mode 12 core G 652 D (termasuk perijinan
PEMDA, PU, Warga)
Idem 24 core
DC-OF-SM-24D
DC-OF-SM-48D
Idem 48 core
DC-OF-SM-96D
Idem 96 core
DC-OF-SM-144D
Idem 144 core
DC-OF-SM-288D
Idem 288 core
DC-OF-SM-432D
Idem 432 core
DC-OF-SM-960D
Idem 960 core
Pengadaan dan pemasangan Kabel Udara Fiber
AC-OF-SM-12D
Optik Single Mode 12 core G 652 D (termasuk
perijinan PEMDA, PU, Warga)
Idem 24 core
AC-OF-SM-24D
AC-OF-SM-48D
Idem 48 core
AC-OF-SM-96D
Idem 96 core
Pengadaan dan pemasangan Kabel Duct Fiber Optik
DC-OF-SM-12C
Single Mode 12 core G 655 C (termasuk perijinan
PEMDA, PU, Warga)
DC-OF-SM-24C
Idem 24 core
DC-OF-SM-48C
Idem 48 core
DC-OF-SM-96C
Idem 96 core
Pengadaan dan pemasangan Kabel Udara Fiber
AC-OF-SM-12C
Optik Single Mode 12 core G 655 C (termasuk
perijinan PEMDA, PU, Warga)
Idem 24 core
AC-OF-SM-24C
AC-OF-SM-48C
Idem 48 core
AC-OF-SM-96C
Idem 96 core
Pengadaan dan pemasangan Kabel Duct Fiber Optik
DC-OF-SM-8-SC
Single Mode 8 core G 652 D, "Easy to split"
(termasuk perijinan PEMDA, PU, Warga)
Idem 12 Core
Idem 24 Core

41
42
43
44
45
46
47
48

GC-OF-SM-2D

49
50

HC-OF-SM-2D

HC-OF-SM-1D

IC-OF-SM-2D

IC-OF-SM-1D

52
53

51

54

SATUAN

meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter
pcs
pcs
pcs
pcs
pcs
core
pcs
pcs
pcs
pcs
pcs
pcs
pcs
meter
meter
meter
meter
meter
meter
meter
meter
meter
meter

meter
meter
meter
meter

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 67
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (2/6)
6.10

DESIGNATOR

URAIAN PEKERJAAN

SATUAN

PC-SC-2-BI

NO

PC-SC-5-BI

pcs

pcs

55

PC-SC-2
PC-SC-5
PC-SC-10
PC-SC-20
PC-FC-20
PC-SC-30
PC-FC-30
PC-SC-40
PC-FC-40
PC-SC-2
PC-SC-5
PC-SC-10
PC-SC-20
PC-FC-20
PC-SC-30
PC-FC-30
PC-SC-40
PC-FC-40
PC-FC-40
Pengadaan dan pemasangan kabinet ODC (Outdoor)
kap 144 core dengan space untuk spliter modular
termasuk material adaptor SC/UPC, pigtail, pondasi
berlapis keramik, lantai kerja, patok pengaman (5
buah), berikut pelabelan

pcs

78

85

84

83

82

81

80

ODP-A-24

ODP-A-16

ODP-A-8

ODP-CA-16

ODP-CA-8

ODP-CU-16

ODP-CU-8

Pengadaan dan pemasangan ODP type Indoor/wall


Kap 48 core berikut space 6 pasive spliter (1:8),
adapter SC/UPC,berikut pelabelan

Pengadaan dan pemasangan ODP type Indoor/wall


Kap 24 core berikut space 3 pasive spliter (1:8),
adapter SC/UPC,berikut pelabelan

Pengadaan dan pemasangan ODP type Indoor/wall


Kap 16 core berikut space 2 pasive spliter (1:8),
adapter SC/UPC,berikut pelabelan

Pengadaan dan pemasangan ODP type Indoor/wall


Kap 8 core berikut space pasive spliter (1:8), adapter
SC/UPC,berikut pelabelan

Pengadaan dan pemasangan ODP type Closure


Aerial Kap 16 core berikut space 2 pasive spliter
(1:8), adapter SC/UPC,berikut pelabelan

pcs

pcs

pcs

pcs

pcs

pcs

pcs

56

ODC-C-144 Splitter

Pengadaan dan pemasangan kabinet ODC (Outdoor)


kap 288 core dengan space untuk spliter modular
termasuk material adaptor SC/UPC, pigtail, pondasi
berlapis keramik, lantai kerja, patok pengaman (5
buah), berikut pelabelan

pcs

pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs
pcs

57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75

ODC-C-288 Splitter

Pengadaan dan pemasangan kabinet ODC (Outdoor)


kap 576 core dengan space untuk spliter modular
termasuk material adaptor SC/UPC, pigtail, pondasi
berlapis keramik, lantai kerja, patok pengaman (5
buah), berikut pelabelan

pcs

Patch cord 2 meter, Bend Insensitive (SC/APC To


SC/UPC) dari Roset ke ONT, G.657
Patch cord 5 meter, Bend Insensitive (SC/APC To
SC/UPC) dari Roset ke ONT, G.657
Patch cord 2 meter, (SC/APC To SC/APC), G.657
Patch cord 5 meter (SC/APC To SC/APC), G.657
Patch cord 10 meter (SC/APC To SC/APC), G.657
Patch cord 20 meter (SC/APC To SC/APC), G.657
Patch cord 20 meter (FC/APC To FC/APC), G.657
Patch cord 30 meter (SC/APC To SC/APC), G.657
Patch cord 30 meter (FC/APC To FC/APC), G.657
Patch cord 40 meter (SC/APC To SC/APC), G.657
Patch cord 40 meter (FC/APC To FC/APC), G.657
Patch cord 2 meter, (SC/UPC To SC/UPC), G.657
Patch cord 5 meter (SC/UPC To SC/UPC), G.657
Patch cord 10 meter (SC/UPC To SC/UPC), G.657
Patch cord 20 meter (FC/UPC To FC/UPC), G.657
Patch cord 20 meter (SC/UPC To SC/UPC), G.657
Patch cord 20 meter (FC/UPC To FC/UPC), G.657
Patch cord 30 meter (SC/UPC To SC/UPC), G.657
Patch cord 40 meter (FC/UPC To FC/UPC), G.657
Patch cord 40 meter (SC/UPC To SC/UPC), G.657
Patch cord 40 meter (FC/UPC To FC/UPC), G.657

76

ODC-C-576 Splitter

Pengadaan dan pemasangan ODC-Pole ( Outdoor )


with space for passive spliter, adaptor SC/UPC kap
48 core, berikut pelabelan

77

ODC -C- 48 Splitter

86

ODP-A-48

Pengadaan dan pemasangan ODP ( Pilar ) kap 8


core termasuk pigtail, berikut space 1 splitter (1:8),
pelabelan.

pcs

79

87

ODP-PL-8

Pengadaan dan pemasangan ODP ( Pilar ) kap 16


core termasuk pigtail, berikut space 2 splitter (1:8),
pelabelan.

pcs

pcs

pcs

88

ODP-PL-16

Pengadaan dan pemasangan ODP type Closure


Underground Kap 8 core with space for splitter,
Adapter SC/UPC
idem 16 core
Pengadaan dan pemasangan ODP type Closure
Aerial Kap 8 core berikut space pasive spliter (1:8),
adapter SC/UPC,berikut pelabelan

89

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 68
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (3/6)
6.10

DESIGNATOR

TC-SM-12

NO

90

TC-SM-24
TC-SM-48
TC-SM-72
TC-SM-96
TC-SM-144

URAIAN PEKERJAAN

Pengadaan dan Pemasangan OTB termasuk


terminasi dan penyambungan kabel optik Single
mode kap 12 core serta Adapter (SC Connector),
pigtail dan protection sleeve pada cassette/box

SATUAN

pcs

pcs
pcs
pcs
pcs
pcs

TC-MK-SC-2P
TC-MK-SC-4P

91
92
93
94
95
pcs

PS-1-2-ODC

RS-IN-SC-1P

100
101

96
pcs
pcs

102
PS-1-4-ODC
PS-1-8-ODC
PS-1-16-ODC
PS-1-32-ODC

RS-IN-SC-2P
RS-IN-SC-4P

103
104
105
106
PS-1-2-ODP

97
98
unit

107
PS-1-4-ODP
PS-1-8-ODP
PS-1-16-ODP
PS-1-32-ODP

TC-MK-SC-1P

108
109
110
111
PS-2-2-ODC

pcs

99

112
PS-2-4-ODC
PS-2-8-ODC
PS-2-16-ODC
PS-2-32-ODC
Pengadaan dan pemasangan Passive Splitter 2:2,
type PLC/Modular, for ODP, termasuk adaptor
pcs
pcs
pcs
pcs
Node

unit
unit

113
114
115
116
PS-2-2-ODP
Idem, 2: 4
Idem, 2 : 8
Idem, 2 : 16
Idem, 2 : 32
Akuisisi Lahan SITAC ODC

133

132

131

130

129

128

127

126

125

124

123

FLEX-PIPE

TC-OF-R-19

TC-XX-ODC

Grounding di Eksisting

GB-G3

GB-G1

PU-AS

PU-SB-7.0-140

GU-G

PU-C9.0-300

PU-S9.0-140

PU-S7.0-140

Pengadaan dan pemasangan Flexible pipe (pipa


spiral) ukuran 1.5 inch termasuk aksesoris.

Pengadaan dan pemasangan rak kabel 19 inch untuk


Fiber Optik Closed Rack, 2,2 Mtr

Pengaddaan dan Pemasangan Rise Pipe untuk


pengaman kabel optik ke ODC Pole / titik naik KU
diamater 1 panjang 3 meter

Pengadaan dan Pemasangan material Grounding di


lokasi gedung eksisting dengan cara integrasi

Pengadaan dan Pemasangan Grounding 3 titik rod


pada ODC dengan maks 1 ohm

Pengadaan dan Pemasangan Grounding 1 titik rod


pada ODP /kotak pembagi dengan maks 3 ohm

Asesoris tiang eksisting

Pengadaan dan pemasangan temberang sokong 7


meter, kekuatan tarik 140 kg

Pengadaan dan Pemasangan Temberang Tarik

Pengadaan dan Pemasangan Tiang Beton 9 meter,


berikut assesories

Pengadaan dan Pemasangan Tiang Besi 9 meter,


berikut cat & cor dan assesories -kekuatan tarik 140
kg

Pengadaan dan Pemasangan Tiang Besi 7 meter,


berikut cat & cor pondasi dan assesories - kekuatan
tarik 140 kg

meter

pcs

pcs

pcs

pcs

pcs

set

pcs

pcs

pcs

pcs

pcs
pcs
pcs
pcs

pcs

pcs
pcs
pcs
pcs

pcs

pcs
pcs
pcs
pcs

pcs

117
PS-2-4-ODP
PS-2-8-ODP
PS-2-16-ODP
PS-2-32-ODP
SITAC ODC

Idem 24 core
Idem 48 core
Idem 72 core
Idem 96 core
Idem 144 core
Pemasangan dan terminasi Roset/Indoor Optical
Outlet with SC Adaptor - kap 1 port berikut pigtail
idem 2 port
idem 4 port
Roset Optik Modular Keystone ( Ditanam ditembok )
dengan SC Adaptor kap 1 port
idem 2 port
idem 4 port
Pengadaan dan pemasangan Passive Splitter 1:2,
type modular, for ODC, termasuk pigtail
Idem, 1 : 4
Idem, 1 : 8
Idem, 1 : 16
Idem, 1 : 32
Pengadaan dan pemasangan Passive Splitter 1:2,
type PLC/Modular, for ODP, termasuk adaptor
Idem, 1 : 4
Idem, 1 : 8
Idem, 1 : 16
Idem, 1 : 32
Pengadaan dan pemasangan Passive Splitter 2:2,
type modular, for ODC, termasuk pigtail
Idem, 2 : 4
Idem, 2 : 8
Idem, 2 : 16
Idem, 2 : 32

118
119
120
121
122

134

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 69
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (4/6)
6.10

135
PP-OF-OUT

PP-OF-IN

DESIGNATOR

136

TC-OF-DC-10

NO

137

URAIAN PEKERJAAN

Pengadaan dan Pemasangan Pipe Protector Indoor


Cable (PVC White) High Impact Conduit 20 mm
Pengadaan dan Pemasangan Pipe Protector
Outdoor Cable ( PVC Black) High Impact Conduit 20
mm
Pengadaan dan pemasangan Duct Cable untuk
Route Kabel menuju Roset, 10x20 mm

SATUAN

meter
meter

meter
meter
meter

144

143

142

140
141

DD-V4-1

DD-S3-3

DD-S3-2

DD-S3-1

TC-OF-CR-200
TC-OF-CR-300

Idem, 2 pipa

Pengadan dan Pemasangan Pipa Duct dengan


pengecoran diameter dalam 100 mm, ketebalan 4
mm, 1 pipa

Pengadaan dan pemasangan Pipa besi diameter


dalam 100 mm dan ketebalan pipa 3,65 mm untuk
crossing 3 pipa

Pengadaan dan pemasangan Pipa besi diameter


dalam 100 mm dan ketebalan pipa 3,65 mm untuk
crossing 2 pipa

Pengadaan dan pemasangan Pipa Besi Diameter


Dalam 100 mm dan ketebalan pipa 3,65 mm untuk
crossing 1 pipa

meter

meter

meter

meter

meter

TC-OF-CR-100

145
DD-V4-2

meter

TC-OF-DC-20

146
DD-V5-1
Idem, 2 pipa

Pemasangan Pipa Duct dengan pasir dia 100 mm , 1


pipa ( crossing )

meter

139

147
DD-V5-2
Pengadaan dan pemasangan pipa Duct menempel
pada jembatan menggunakan Pipa Galvanis
diamenter dalam 100 mm, tebal 3,65 mm, 1 pipa

meter

138

148

DD-DA-S1

Pengadaan dan pemasangan pipa Duct pada


jembatan dengan menempel menggunakan Pipa besi
Galv 1 pipa (Parit)

meter
meter

149

DD-BSS-S1

idem 20x40 mm
Pengadaan dan pemasangan Tray Cable, Lebar 100
mm tebal 5 mm Alumunium disesuaikan kebutuhan
idem 200 mm
idem 300 mm

150

DD-BTS-S1

meter

meter

151

166

165

164

163

161
162

160

159

158

157

156

155

154

153

152

DD-HDPE-1

DD-BM-HDPE-2

DD-BM-HDPE-1

DD-BM-2

DD-BM-1

DCD-PVC-2
DCD-PVC-4

DCD-PVC-1

DC-SD-2 Big

DC-SD-1 Big

DC-SD-3

DC-SD-1

DD-BMR

HB-PS-2

HB-PS-1

DD-BTS-S2

Pengadaan dan pemasangan Pipa Duct dengan


system gantung 2 pipa bentang lebih 40 meter

Pengadaan dan pemasangan Pipa Duct dengan


system gantung 1 pipa bentang s/d 40 meter

meter

meter

meter

167

DD-HDPE-2

Pengadaan dan pemasangan Pipa Duct dengan


penguat sendiri 1 pipa
Pengadaan dan pemasangan Pipa Duct dengan
penguat sendiri 2 pipa

168

DD-RV-1

DD-ROD

Pengadaan dan Pemasangan 1 pipa HDPE/HDPE


BIG untuk kabel FO, Include Soket HDPE
Idem 2 pipa
Pembersihan pada route Duct yang kosong / Rodding
Duct Existing.
Perbaikan Route Duct / HDPE, 1 pipa.

meter

meter

meter

meter

meter

meter

meter

meter
meter

meter

meter

meter

meter

meter

track

169

Boring pada Lintasan Kereta Api menggunakan 2


pipa
Pengadaan dan Pemasangan 1 Subduct 27/32 mm
pada polongan route Duct
Pengadaan dan Pemasangan 3 Subduct 27/32 mm
pada polongan route Duct
Pengadaan dan Pemasangan 1 Subduct Big pada
polongan route Duct
Pengadaan dan Pemasangan 2 Subduct Big pada
polongan route Duct
Pembuatan Duct Cable Distribusi diameter pipa PVC
2 inc AW 1 pipa
idem 2 pipa
idem 4 pipa
Pemasangan Pipa Duct dengan cara boring manual
/mesin 1 pipa
Idem 2 pipa
Boring manual/mesin untuk HDPE / Micro Duct
diameter dalam 33 mm 1 pipa kedalaman 1,5 meter
Idem, 2 pipa

170

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 70
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (5/6)
6.10

URAIAN PEKERJAAN

SATUAN

178
179

177

DD-MDDI-2A
DD-MDDI-4A
DD-MDDI-7A
DD-MDDI-12A
DD-MDDI-19A
DD-MDDI-24A

DD-MDDI-1A

SMD-ABS-3A
SMD-ABS-4A

SMD-ABS-2A

DESIGNATOR

180

DD-MDDI-1B

NO

m3

181
182
183
184
185
186

DD-MDDI-2B
DD-MDDI-4B
DD-MDDI-7B

DD-RV-CONCRETE

187

DD-MDDI-1C

171
meter

188
189
190

DD-MDDI-2C
DD-MDDI-4C
DD-MDDI-7C

BC-TR-0.4

191

DD-MDDB-1A

172

meter

192
193
194

DD-MDDB-2A
DD-MDDB-4A
DD-MDDB-7A
DD-MDDB-12A
DD-MDDB-19A
DD-MDDB-24A

BC-TR-0.6

195

DD-MDDB-1B

meter

173

meter

196
197
198
199
200
201

DD-MDDB-2B
DD-MDDB-4B
DD-MDDB-7B

Pengadaan dan Pemasangan 12/10mm Micro Duct,


Direct Buried, 1 way, untuk Air Blown kabel FO
termasuk connector

meter

BC-TR-5

202

DD-MDDB-1C

Idem 2 way

m3

meter
meter
lbr
lbr
pcs
pcs
pcs
pcs
pcs
pcs

174
Titik

203
204
205

DD-MDDB-2C

Modifikasi Manhole/Handhole (sesuai luasan)

Idem 4 way
Idem 7 way
Gambar Kertas kalkir ukuran A1 Hard Copy & Soft
Gambar Kertas lighdruk ukuran A1
Pembuatan Manhole Lurus Type HIS5
Pembuatan Manhole Type HIS5T
Pembuatan Manhole Type HIIS7
Pembuatan Handhole Type HH1
Pembuatan Handhole Type HH2
Peninggian Tutup Manhole/Handhole

BD-SK

206

DD-MDDB-4C
DD-MDDB-7C
GB-K-A1
GB-L-A1
MH-HIS5
MH-HIS5T
MH-HII S 7
MH-HH1
MH-HH2
MH-CA

175
Titik

207

MH-MOD

pcs

208
209
210
211
212
213
214
215
216
217

Pembuatan HH ukuran diameter dalam (P X L X T =


60x40x60) cor beton 1 : 2 : 3
Pembuatan HH ukuran diameter dalam (P X L X T =
40x40x40) cor beton 1 : 2 : 3

pcs

pcs

kg

meter

meter
meter
meter
meter
meter
meter

meter

meter
meter
meter

meter

meter
meter
meter

meter

meter
meter
meter
meter
meter
meter

meter

pcs
pcs

218

MH-RS

BP-IC

meter
meter
meter

219

HH-PIT-60

176

Relocate dan Exspand Pipa in Counter Wall by Bobok


Concrete
Galian, Pengurugan kembali dan perbaikan kembali,
pengisian pasir, deeksten dan tanda rute kabel tanah
dan tempat sambung kedalaman 0.4 meter
Galian, Pengurugan kembali dan perbaikan kembali,
pengisian pasir, deeksten dan tanda rute kabel tanah
dan tempat sambung kedalaman 0.6 meter
Galian, Pengurugan kembali dan perbaikan kembali,
pengisian pasir, deeksten dan tanda rute kabel tanah
dan tempat sambung kedalaman 1,5 meter
Pembobokan dan perbaikan Dinding untuk lubang
Sparing Kabel
Pembobokan dan perbaikan Plafon untuk route Indoor
Cable
Pengadaan dan pemasangan Alat Sambung Micro
Duct cabang/lurus 2 cabang,termasuk connector,gas
block & end cap
idem 3 cabang
idem 4 cabang
Pengadaan dan Pemasangan 5/3.5mm Micro Duct,
Direct Install, 1 way, untuk Air Blown kabel FO
termasuk connector
Idem 2 way
Idem 4 way
Idem 7 way
Idem 12 way
Idem 19 way
Idem 24 way
Pengadaan dan Pemasangan 10/8mm Micro Duct,
Direct Install, 1 way, untuk Air Blown kabel FO
termasuk connector
Idem 2 way
Idem 4 way
Idem 7 way
Pengadaan dan Pemasangan 12/10mm Micro Duct,
Direct Install, 1 way, untuk Air Blown kabel FO
termasuk connector
Idem 2 way
Idem 4 way
Idem 7 way
Pengadaan dan Pemasangan 5/3.5mm Micro Duct,
Direct Buried, 1 way, untuk Air Blown kabel FO
termasuk connector
Idem 2 way
Idem 4 way
Idem 7 way
Idem 12 way
Idem 19 way
Idem 24 way
Pengadaan dan Pemasangan 10/8mm Micro Duct,
Direct Buried, 1 way, untuk Air Blown kabel FO
termasuk connector
Idem 2 way
Idem 4 way
Idem 7 way

220

HH-PIT-40

Instalasi struktur rak dalam manhole yang ada.

221

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 71
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
LIST OF ASSEMBLY UNIT DESIGNATOR (6/6)
6.10

new

222

DD-V4-4

DD-HDPE-Big

NEW ITEM

HH-PIT-Portable

DESIGNATOR

new
HH-80

NO

new
new
new

URAIAN PEKERJAAN

Pengadaan dan pemasangan HH Pit Portable


beserta aksesorisnya
Pengadaan dan Pemasangan 1 pipa HDPE/HDPE
BIG untuk kabel FO, Include Soket HDPE
Pengadan dan Pemasangan Pipa Duct dengan
pengecoran diameter dalam 100 mm, ketebalan 4
mm, 4 pipa
Pembuatan HH ukuran diameter dalam (P X L X T =
80x80x80) cor beton 1 : 2 : 3
Cable Tray / Ladder (Plastic) 40x40 mm Berikut
Assesories
Cable Tray /Ladder (Plastic) 16x16 mm Berikut
Assesories

SATUAN

meter
OK

UNTUK 288

pcs

meter
pcs
meter
meter

BC-PP

pcs

OK

OK

new
ODC-HRB-180
ODC-HRB-240
ODC-HRB-420
ODP-HRB-16
ODP-HRB-32
Pengadaan dan pemasangan ODP type Closure
Aerial (SSW) Kap 8 core berikut space pasive spliter
(1:8), adapter SC/UPC, berikut pelabelan

pcs

OK

pcs

new
new
new
new
new
ODP-SSW-8

Pengadaan dan pemasangan ODP type Oudoor/wall


Kap 8 core berikut space pasive spliter (1:8), adapter
SC/UPC,berikut pelabelan

pcs

Pengaddaan dan Pemasangan Rise Pipe Besi untuk


pengaman kabel optik / titik naik KU dan Grounding
diamater 1,5 inch panjang 3 meter

new

ODP-PW-8

Pengadaan dan pemasangan ODP type Oudoor/wall


Kap 16 core berikut space 2 pasive spliter (1:8),
adapter SC/UPC,berikut pelabelan

OK
OK
OK
OK
OK

new

ODP-PW-16

pcs
pcs
pcs
pcs
pcs

new
pcs
pcs
Core

ODP-PW-BR-16
ODP-PL-BR-16
Pengukuran Cable Existing

new
new
new

KETERANGAN

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 72
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

CopyrightFujikura Ltd./Y.N

Page 73

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

CopyrightFujikura Ltd./Y.N

Page 74

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Work Flow to Test-Com(Internal Commissioning Test) and UT (PAT)
Construction
Work

Civil Work
FOC Laying Work
FOC Joint Work
FOC Termination Work

Test-Com
(Internal Test)
(for optical test on Fiber)

OTDR Measurement

Pass
Preparation of OPM Test Form

Fail
1. High Loss Event Detection
by OTDR 1.55um for;
1) Feeder Segment,
2) Distribution Segment
2. Fiber Length Measurement

Total Loss Measurement


by LS/OPM

UT (PAT)
CopyrightFujikura Ltd./Y.N

UT
Page 75

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Typical System Cofiguration between OTB and ODP

1:4 splitter
Port#.1

Feeder
Cable

Port#.1
Splitter
#.1

Port#.1

Port#.1

Distribution
Cable

Feeder
Cable

CopyrightFujikura Ltd./Y.N

1:4 splitter

1 2 3 4 5 6 7 8 9 10 11 12

4 5 6

7 8

9 10 11 12

4 5 6

7 8

9 10 11 12

4 5 6

7 8

9 10 11 12

4 5 6

7 8

9 10 11 12

Page 76

Port#.1

1:8
splitter

1:8 splitter
1 2 3 4 5 6 7 8 9 10 11 12

ODP
No.2
Splitter #.2

ODP
No.1

ODC

Splitter #.1

OTB

1
2
3
4
5
6
7
8

1:8 splitter
1
2
3
4
5
6
7
8

Distribution
Cable

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

Definition of Segment
BIF
patchcord

Bi-directional OTDR Measurement shall


be done upon request by TELKOM

OLT

ODC

OTB
fo
Feeder

1:4 splitter

Feeder Segment

Rosette

ODP
fo
Distribution

ONT

fo
Drop

1:8 splitter

Distribution Segment

Overall Segment (OTB - ODP)

(Drop Segment)

Splice
SC/UPC connector

CopyrightFujikura Ltd./Y.N

Page 77

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
Policy of Test for Optial Measurement

OTDR ; detect partially harmful waveform =only 1.55um (sensitive for fiber bend)
LS/OPM ; for guarantee the final performance of the line

1) Feeder Segment
1-1) Measurment by OTDR with one-way to detect partially harmful event
(Bi-directional Measurement shall be done for Segment A - Segment A' upon request by TELKOM.)
1-2) Measurment by LS/OPM
2) Distribution Segment
2-1) Measurment by OTDR from ODC to ODP splitter input (one-way)
(because Handy OTDR cannot measure over 1:8 splitter)
2-2) Measurment by LS/OPM
3) Drop Segment
Measurment by LS/OPM
(Drop Segment cannot be measured by OTDR because drop cable length is <100m)
4) End to End ; Overall Section
Measurment only by LS/OPM
(because Handy OTDR cannot measure over 1:8 splitter)
CopyrightFujikura Ltd./Y.N

Page 78

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

KALIBRASI (Input Power Measurement)


Prior to LS/OPM Measurement, the INPUT
POWER (Pi) shall be measured and recorded.
TAKE OUT
(OPM SIDE)

DO NOT
TAKE OUT

Optical
Light
Source

NEW
Patch-cord

Optical
Power
Meter

Method of Measurement
Leave the Light Source 5 10 min. to
make the input power (Pi) stable after
switch on.

Check Pi three (3) times at least


Max.Pi - Min.Pi < 0.1dB
Average Pi
Ex.
Good
1st - 8.20dBm
2nd -8.18dBm
3rd -8.22dBm
Ave -8. 20dBm

Bad
-8.20dBm
-8.18dBm
-8. 07dBm

Pi = 8.20dB

NEW Battery
Optical
Light Source
CopyrightFujikura Ltd./Y.N

Optical
Power Meter
Page 79

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.1

Feeder Segment
ODC

OTB
fo
Feeder
OTDR

1:4 splitter
Segment A'

Segment A

Segment A' cannot be measured by


OTDR because 4-OTDR signal overlap
in this segment.
Optical performance of this segment
is guaranteed by Test Report of splitter
module and measurment
of Segment A by LS/OPM

ODC

OTB
fo
Feeder
Optial Light
Source

OTDR@1550nm

1:4 splitter
Segment A'

Segment A
Patchcord is
not needed for
measurment

CopyrightFujikura Ltd./Y.N

Page 80

LS/OPM
@1310nm & 1550nm
Optical Power
Meter
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.2

Distribution Segment-1 (SCPT and SSW; ODP installed)


ODC

ODP
fo
Distribution

OTDR
Segment B

1:8 splitter
Segment B'

Bi-directional mesurement by ODR is not


possible because Handy OTDR cannot
measure over 1:8 splitter.

ODP

ODC
fo
Distribution
Optial Light
Source
CopyrightFujikura Ltd./Y.N

Segment B
Page 81

1:8 splitter

OTDR@1550nm
Segment B' cannot measure by OTDR
because 8-OTDR signal overlap in this
segment.
Optical performance of this segment is
guaranteed by Test Report of splitter
module and measurment of Segment
B by LS/OPM.

LS/OPM
@1310nm & 1550nm
Optical Power
Meter
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.3

Distribution Segment-2
 SCPT/SSW CADANGAN or,
 SSW; ODP not installed, only cable installed

OTDR@1550nm

ODC
fo
Distribution
OTDR

Segment B
temporarily splice pigtail to end
of fiber
ODC
fo
Distribution

Optial Light
Source
CopyrightFujikura Ltd./Y.N

Segment B
Page 82

LS/OPM
@1310nm&1550nm
Optical Power
Meter
HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.4

Drop Segment
ODP

Rosette
fo
Drop

Optial Light
Source

LS/OPM
@1310nm&1550nm
Optical Power
Meter

Segment C

Drop segment cannot be measured by


OTDR because drop cable length is
<100m.

CopyrightFujikura Ltd./Y.N

Page 83

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.5

End to End Overall (SCPT and SSW; ODP installed)


LS/OPM
@1310nm & 1550nm
ODP

ODC

OTB
fo
Feeder

Segment A

Optial Light
Source

CopyrightFujikura Ltd./Y.N

1:4 splitter

Segment D

Rosette

fo
Distribution

fo
Drop
1:8 splitter

Segment B

Segment C

Note:
Overall segment cannot be measured by OTDR
because splitter is included in the line.
Page 84

Optical
Power Meter

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

1.6

Calculation of Attenuation Limit (LS/OPM Test)


Segment

Calculation of Attenuation Limit

Remarks

1. Feeder Cable Segment


- 1310nm

A-F13= {0.35dB/km x ,.. Km} + {0.1dB x (No. of Splice)} +


{0.25dB x (No. of Connector)}

A-F13: Attenuation Limit of Feeder


Cable at 1310nm

- 1550nm

A-F15= {0.215dB/km x ,.. Km} + {0.1dB x (No. of Splice)} +


{0.25dB x (No. of Connector)}

A-F15: Attenuation Limit of Feeder


Cable at 1550nm

2. Distribution Cable Segment


- 1310nm

A-D13= {0.35dB/km x ,.. Km} + {0.1dB x (No. of Splice)} +


{0.25dB x (No. of Connector)}

A-D13: Attenuation Limit of


Distribution Cable at 1310nm

- 1550nm

A-D15= {0.215dB/km x ,.. Km} + {0.1dB x (No. of Splice)} +


{0.25dB x (No. of Connector)}

A-D15: Attenuation Limit of


Distribution Cable at 1550nm

- 1310nm

A-DR13= {0.35dB/km x ,.. Km} + {0.25dB x (No. of


Connector)}

A-DR13: Attenuation Limit of


Distribution Cable at 1310nm

- 1550nm

A-DR15= {0.215dB/km x ,.. Km} + {0.25dB x (No. of


Connector)}

A-DR15: Attenuation Limit of


Distribution Cable at 1550nm

3. Drop Cable Segment

4. End to End/Overall Section


- 1310nm

A-EE13= [A-F13] + 7.5dB (Splitter 1x4) + [D-F13] + 11.0dB


(Splitter 1x8) + [A-DR13]

A-EE13: Overall Attenuation of End


to End at 1310nm

- 1550nm

A-EE15= [A-F15] + 7.5dB (Splitter 1x4) + [D-F15] + 11.0dB


(Splitter 1x8) + [A-DR15]

A-EE15: Overall Attenuation of End


to End at 1550nm

CopyrightFujikura Ltd./Y.N

Page 85

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

CopyrightFujikura Ltd./Y.N

Page 86

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
APPLICATION OF MEASUREMENT FORMS
ODC
Feeder
Cable

Port#.1
1

1:8
splitter

Distribution
Cable

1:4 splitter
Port#.1

ODP No.X

Port#.1

Splitter
#.1

OTB

Splitter
#.1

2.1

Port#.1
5

Form IIc / IId

Form IIIa / IIIb

(Feeder Segment / Seg.A)

(Distribution Segment / Seg.B)

Form IIa / IIb


(Feeder Segment / Seg.A)

Form Ia / Ib
(Overall Segment)

Form #

IIa / IIb

Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm


Subsystem: Feeder Segment (OTB-ODC) without splitter

From / To
From: OTB
To: ODP
From: OTB
To: ODC

IIc / IId

Seg.A(OTB-ODC_splitter) Loss Measurement 1310nm/ 1550nm


Subsystem: Feeder Segment (OTB-ODC) with passive splitter 1:4

From: OTB
To:ODC

Seg.B(ODC-ODP) Loss Measurement 1310nm/1550nm


Subsystem: Segment B (ODC - ODP)

From: ODC
To: ODP

Ia / Ib

IIIa / IIIb
CopyrightFujikura Ltd./Y.N

Name
Total Loss Measurement 1310nm / 1550nm
Subsystem: Oerall Segment (OTB-ODC-ODP)

Page 87

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.1.1 FORM I a/I b: Overall Segment (OTB-ODC-ODP)
1:4 splitter
Port#.1
Port#.1

Feeder
Cable

Splitter#.1

Port#.1

ODC

6
Distribution
Cable

ODP No.X
Port#.1
1:8
splitter

Splitter#.1

OTB

3
OVERALL SEGMENT

1
NOTE:

1) Input in accordance with


the site information, condition

Distribution Cable Core No.


to be terminated at ODP

2) Input when measurement

6
3

CopyrightFujikura Ltd./Y.N

Page 88

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.1.2 FORM II a/II b: Feeder Segment (OTB-ODC) without splitter

Port#.1

Feeder
Cable

1:4 splitter
Port#.1
Port#.1
2

Distribution
Cable

ODP No.X
Port#.1
1:8
splitter

Splitter#.1

ODC
Splitter#.1

OTB

FEEDER SEGMENT

NOTE:

1) Input in accordance with the


site information, condition

2) Input when measurement

Input Tray No.

CopyrightFujikura Ltd./Y.N

Page 89

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.1.3 FORM II c/II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter

Feeder
Cable

Port#.1
1

1:4 splitter
Port#.1
Port#.1
4
2

6
Distribution
Cable

ODP No.X
Port#.1
1:8
splitter

Splitter#.1

ODC
Splitter#.1

OTB

FEEDER SEGMENT with Splitter

NOTE:

1) Input in accordance with the


site information, condition

2) Input when measurement

CopyrightFujikura Ltd./Y.N

Page 90

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.1.4 FORM III a/III b: Distribution Segment (ODC-ODP)
Feeder
Cable

Port#.1
1

1:4 splitter
Port#.1
Port#.1
4
2

Distribution
Cable

ODP No.X
Port#.1
1:8
splitter

Splitter#.1

ODC
Splitter#.1

OTB

3
DISTRIBUTION SEGMENT

NOTE:

1) Input in accordance with the


site information, condition

4
5

2) Input when measurement

CopyrightFujikura Ltd./Y.N

Page 91

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.2

MEASUREMENT FORMS (File: UT-Form Measurement -r2.2.xls)

Note:
1) Forms provided hereunder is "r-2.3a", which is the
latest version as of 28 June, 2013.
2) It is to request users to confirm the latest version to JF
DJAFa Consortium before use Forms.
3) Use Forms of Excel format for submission purpose.
4) In case if the form is not enough (e.g. more than 5 ODP
(1:8 Splitter) are exist in one distribution cable), the
related "Worksheet of Excel" (e.g. Form I and III) shall
be duplicated/copied.
5) Do not incert any Line/Raw in the form so as not to
alter the calculation formula in the sheet.

CopyrightFujikura Ltd./Y.N

Page 92

HANDBOOK for FTTH-OSP v 1.0 (June 2013)

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.1 FORM I a: Overall Segment (OTB-ODC-ODP) @ 1310nm

FORM : I a

STO
NAMA
LOKASI

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

Splitter-.3
-

Splitter-.4

0.00

E 0000'00"
WAVE LENGTH

S 0000'00"
CABLE No.

1310nm

0000'00"
0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

REMARKS

No of Cores

DATE OF MEASUREMENT:

Overall Loss Measurement 1310 nm

PT TELEKOMUNIKASI INDONESIA

DAERA

COORDINATES
DISTRIBUTION CABLE
Measurement tools : Power Meter

PASS

PASS

PASS

0.00

ODP COORDINATES
S
E

dB (Cable length x 0.35 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

ATTENUATION (dB)
RESULT
Pin (dB) Pout (dB) Pout-Pin (dB) PASS/FAIL

ODP
LOSS
Port No. BUDGET

Specification/limitation :

No of Cores
OTB Port No.

CABLE No.

CAPACITY

Sub Sistem : OVERALL SEGMENT (OTB - ODC - ODP)

ODC No.

No.

FEEDER CABLE

ODC
PORT No.
Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Catatan: Power Meter digunakan untuk test pelurusan kabel

0.00

Splitter-.2

*) Total Loss = (Cable length x 0,35 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

Splitter-.1

0.00

DISTRIBUTIO DISTRIBUTIO DISTRIBUTIO DISTRIBUTIO


N
N
N
N
Note: CABLE LENGTH of OTDR Indication

FEEDER

0.35
0.1
0.25
7.25
10.38

Unit
Attenuation

CALCULATION OF LOSS BUDGET:

1. CABLE LENGTH (km)


2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
4. SPLITTER 1:4 (1 pc)
5. SPLITTER 1:8 (1 pc)
ATTENUATION LIMITATION (dB)

CABLE LENGTH (km):

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 93
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.2 FORM I b: Overall Segment (OTB-ODC-ODP) @ 1550nm

FORM : I b

STO
NAMA
LOKASI

COORDINATES

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

Splitter-.4

0.00

E 00 00'00"
WAVE LENGTH

S 00 00'00"
CABLE No.

1550nm

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

0000'00"

REMARKS

Remarks

No of Cores

DATE OF MEASUREMENT:

Total Loss Measurement 1550 nm

PT TELEKOMUNIKASI INDONESIA

CABLE No.
DISTRIBUTION CABLE

Result

PASS

Splitter-.3

0.00

ODP COORDINATES
S
E

dB (Cable length x 0.215 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

PASS

PASS

ATTENUATION (dB)
RESULT
Pin (dB) Pout (dB) Pout-Pin (dB) PASS/FAIL

ODP
LOSS
Port No. BUDGET

Specificationlimitation
Attenuation (dB)

Specification/limitation :

No of Cores
OTB Port No.

DAERA

ODP

CAPACITY

Sub Sistem : OVERALL SEGMENT (OTB - ODC - ODP)

ODC No.

ODP Port No.

No.

FEEDER CABLE

ODC
PORT No.
Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Core No.

ODP No.

Splitter No.

Splitter-.2

0.00

DISTRIBUTIO DISTRIBUTIO DISTRIBUTIO DISTRIBUTIO


N
N
N
N
Note: CABLE LENGTH of OTDR Indication

FEEDER

Unit
Splitter-.1
Attenuation
0.215
0
0.1
0.25
7.25
10.38
0.00

*) Total Loss = (Cable length x 0,215 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)
CALCULATI
ON OF
ATTENUATI
ON LIMIT:

1. CABLE LENGTH (km)


2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
4. SPLITTER 1:4 (1 pc)
5. SPLITTER 1:8 (1 pc)
ATTENUATION LIMITATION (dB)

CABLE LENGTH (km):

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 94
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.3 FORM II a: Feeder Segment (OTB-ODC) without splitter @ 1310nm

FORM : II a

STO

ODC

NAMA
LOKASI

CAPACITY

NAME/TYPE

Measurement tools : Power Meter


dB (Cable length x 0.35 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

S 0000'00"

DATE OF MEASUREMENT:

Seg.A(OTB-ODC_splitter) Loss Measurement 1310 nm

PT TELEKOMUNIKASI INDONESIA

No. of Cores

CABLE No.

DAERA

Sub Sistem : FEEDER SEGMENT (OTB - ODC) WITHOUT SPLITTER

FEEDER CABLE

ODC COORDINATES
Specification/limitation :

15

14

13

12

11

10

12

11

10

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

16
5

PASS

RESULT
PASS/FAIL

17
6

PASS

ATTNUATION (dB)
Pout (dB)
Pout - Pin (dB)

18
7

PASS

Pin (dB)

19
8

PASS

LOSS
BUDGET

20
9

PASS

ODC
Tray No. Port No.

21
10

OTB
PORT No.

22
11

No.

23

PASS

PASS

PASS

PASS

12

PASS

24

PASS

PASS

PASS

30

PASS

31

PASS

25

32

10

PASS

PASS

33

11

PASS

34

12

PASS

35

PASS

26

36

PASS

PASS

37

PASS

38

PASS

39

PASS

27

40

PASS

PASS

41

PASS

42

PASS

43

28

44

10

45

11

46

12

29

47

ODC

0.00

48

Catatan: Power Meter digunakan untuk test pelurusan kabel

*) Total Loss = (Cable length x 0,35 dB + Connector x 0.25dB + Splice x 0.1dB)

CALCULATION OF ATTENUATION LIMIT:


0.35
0.1

Unit Attenuation
1. CABLE LENGTH (km)
2. No. of SPLICE (pcs)

0.25
FEEDER
Note: CABLE LENGTH of OTDR Indication

3. No. of CONNECTOR (pcs)


ATTENUATION LIMITATION (dB)
CABLE LENGTH (km)

WAVE LENGTH

1310nm
E 00 00'00"

REMARKS

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 95
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.4 FORM II b: Feeder Segment (OTB-ODC) without splitter @ 1550nm

FORM : II b

STO

ODC

NAMA
LOKASI
NAME/TYPE
CAPACITY

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

12

11

10

12

11

10

12

11

10

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

WAVE LENGTH

1550nm

REMARKS

E 0000'00"

dB (Cable length x 0.215 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

Measurement tools : Power Meter

S 0000'00"

DATE OF MEASUREMENT:

Seg.A(OTB-ODC_splitter) Loss Measurement 1550 nm

PT TELEKOMUNIKASI INDONESIA

CABLE No.

DAERA

Sub Sistem : FEEDER SEGMENT (OTB - ODC) WITHOUT SPLITTER

FEEDER
CABLE
No. of Cores

ODC COORDINATES
Specification/limitation :

38

PASS

PASS

39

PASS

RESULT
PASS/FAIL

40

PASS

ATTNUATION (dB)
Pout (dB)
Pout - Pin (dB)

41

PASS

Pin (dB)

42

PASS

LOSS
BUDGET

43

OTB
ODC
PORT No. Tray No. Port No.

44

10

No.

45

11

46

12

47

ODC

0.00

48

Catatan: Power Meter digunakan untuk test pelurusan kabel

*) Total Loss = (Cable length x 0,215 dB + Connector x 0.25dB + Splice x 0.1dB)

Unit Attenuation
0.215
0.1
0.25

Note: CABLE LENGTH of OTDR Indication

FEEDER

CALCULATION OF ATTENUATION LIMIT:


1. CABLE LENGTH (km)
2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
ATTENUATION LIMITATION (dB)
CABLE LENGTH (km)

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 96
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.5 FORM II c: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1310nm

FORM : II c

STO

ODC

NAMA
LOKASI
NAME/TYPE
CAPACITY

dB (Cable length x 0.35 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

Measurement tools : Power Meter

S 00 00'00"

DATE OF MEASUREMENT:

Seg.A(OTB-ODC_splitter) Loss Measurement 1310 nm

PT TELEKOMUNIKASI INDONESIA

CABLE No.

DAERA

Sub Sistem : FEEDER SEGMENT (OTB - ODC) WITH PASSIVE SPLITTER 1:4

FEEDER CABLE
No. of Cores

ODC COORDINATES
Specification/limitation :

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

10

11

12

PASS

38

PASS

RESULT
PASS/FAIL

39

PASS

ATTNUATION (dB)
Pout (dB)
Pout - Pin (dB)

40

PASS

Pin (dB)

41

PASS

LOSS
BUDGET

42

PASS

ODC
Splitter Port No.

43

OTB
PORT No.

44

No.

45

46

47

48

Catatan: Power Meter digunakan untuk test pelurusan kabel

0.00

ODC

*) Total Loss = (Cable length x 0,35 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

0.35

Unit Attenuation

CALCULATION OF ATTENUATION LIMIT:

0.1
0.25

1. CABLE LENGTH (km)


2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)

7.25
FEEDER
Note: CABLE LENGTH of OTDR Indication

4. SPLITTER 1:4 (1 pc)


ATTENUATION LIMITATION (dB)
CABLE LENGTH (km)

1310nm

WAVE LENGTH

E 0000'00"

REMARKS

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 97
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.6 FORM II d: Feeder Segment (OTB-ODC) with 1:4 Passive Splitter @ 1550nm

FORM : II d

STO

ODC

NAMA
LOKASI

CAPACITY

NAME/TYPE

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

RESULT
PASS/FAIL

10

11

12

WAVE LENGTH

1550nm

REMARKS

E 0000'00"

dB (Cable length x 0.215 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

Measurement tools : Power Meter

S 0000'00"

DATE OF MEASUREMENT:

Seg.A(OTB-ODC_splitter) Loss Measurement 1550 nm

PT TELEKOMUNIKASI INDONESIA

No. of Cores

CABLE No.

DAERA

Sub Sistem : FEEDER SEGMENT (OTB - ODC) WITH PASSIVE SPLITTER

FEEDER
CABLE

ODC COORDINATES
Specification/limitation :

ATTNUATION (dB)
Pout (dB)
Pout - Pin (dB)
PASS

Pin (dB)
PASS

LOSS
BUDGET

PASS

OTB
ODC
PORT No. Splitter Port No.

1
2

No.

2
3

1
3
4

46

47

48

Catatan: Power Meter digunakan untuk test pelurusan kabel

0.00

ODC

*) Total Loss = (Cable length x 0,215 dB + Connector x 0.25dB + Splitter 1:4 x 7.25dB + Splice x 0.1dB)

Unit Attenuation
0.215
0.1
0.25
7.25

Note: CABLE LENGTH of OTDR Indication

FEEDER

CALCULATION OF ATTENUATION LIMIT:


1. CABLE LENGTH (km)
2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
4. SPLITTER 1:4 (1 pc)
ATTENUATION LIMITATION (dB)
CABLE LENGTH (km)

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 98
CopyrightFujikura Ltd./Y.N

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.7 FORM III a: Distribution Segment (ODC-ODP) @ 1310nm

FORM : III a

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

DATE OF MEASUREMENT:
NAMA
LOKASI

WAVE LENGTH

E 00 00'00"
CABLE No.

1310nm

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

Splitter-.4

00 00'00"

00 00'00"

00 00'00"

00 00'00"

0000'00"

0000'00"

0000'00"

0000'00"

REMARKS

No of Cores

S 0000'00"
DISTRIBUTION CABLE

PASS

Splitter-.3

0.00

0.00

Splitter-.2

0.00

0.00

Splitter-.1

*) Total Loss = (Cable length x 0.35 dB + Connector x 0.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

CALCULATION OF ATTENUATION LIMIT:


Unit
Attenuation
0.35
0.1
0.25
10.38

DISTRIBUTION DISTRIBUTION DISTRIBUTION DISTRIBUTION


Note: CABLE LENGTH of OTDR Indication

ODP COORDINATES
S
E

Measurement tools : Power Meter


dB (Cable length x 0.35 dB + Connector x 0.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

PASS

ATTENUATION (dB)
RESULT
Pin (dB)
Pout (dB) Pout-Pin (dB) PASS/FAIL

LOSS
BUDGET

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

STO

Seg.B (ODC-ODP) Loss Measurement 1310 nm

PT TELEKOMUNIKASI INDONESIA

No.

S P L IT T E R N o ._ _ _ _ _ _ _

ODP
Port

CAPACITY

S P L IT T E R N o ._ _ _ _ _ _ _

Specification/limitation :

ODC COORDINATES

DAERA

Sub Sistem : SEGMENT B (ODC - ODP)

ODC

S P L IT T E R N o ._ _ _ _ _ _ _

SPLITTER
No. ODP
1:4

S P L IT T E R N o ._ _ _ _ _ _ _

O D P N o ._ _ _ _ _ _ _ _ _

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

O D P N o ._ _ _ _ _ _ _ _ _

Catatan: Power Meter digunakan untuk test pelurusan kabel

O D P N o ._ _ _ _ _ _ _ _ _

1. CABLE LENGTH (km)


2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
5. SPLITTER 1:8 (1 pc)
ATTENUATION LIMITATION (dB)

CABLE LENGTH (km):

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 99
CopyrightFujikura Ltd./Y.N

O D P N o ._ _ _ _ _ _ _ _ _

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)

2.2.8 FORM III b: Distribution Segment (ODC-ODP) @ 1550nm

FORM : III b

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

O D C P o rt N o ._ _ _ _ _ _ _

DATE OF MEASUREMENT:
NAMA
LOKASI

WAVE LENGTH

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

E 0000'00"
CABLE No.

1550nm

PASS

Splitter-.1

0.00

Splitter-.2

0.00

Splitter-.3

0.00

Splitter-.4

REMARKS

No of Cores

S 00 00'00"
DISTRIBUTION CABLE

PASS

0.00

*) Total Loss = (Cable length x 0.215 dB + Connector x 0.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

CALCULATION OF ATTENUATION LIMIT:


Unit
Attenuation
0.215
0.1
0.25
10.38

DISTRIBUTION DISTRIBUTION DISTRIBUTION DISTRIBUTION


Note: CABLE LENGTH of OTDR Indication

ODP COORDINATES
S
E

Measurement tools : Power Meter


dB (Cable length x 0.215 dB + Connector x 0.25dB + Splitter 1:8 x 10.38dB + Splice x 0.1dB)

ATTENUATION (dB)
RESULT
Pin (dB)
Pout (dB) Pout-Pin (dB) PASS/FAIL

PASS

LOSS
BUDGET

PASS

STO

Seg.B (ODC-ODP) Loss Measurement 1550 nm

PT TELEKOMUNIKASI INDONESIA

No.

S P L IT T E R N o ._ _ _ _ _ _ _

ODP
Port

CAPACITY

S P L IT T E R N o ._ _ _ _ _ _ _

Specification/limitation :

ODC COORDINATES

DAERA

Sub Sistem : SEGMENT B (ODC - ODP)

ODC

S P L IT T E R N o ._ _ _ _ _ _ _

SPLITTER
No. ODP
1:4

S P L IT T E R N o ._ _ _ _ _ _ _

O D P N o ._ _ _ _ _ _ _ _ _

2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

O D P N o ._ _ _ _ _ _ _ _ _

Catatan: Power Meter digunakan untuk test pelurusan kabel

O D P N o ._ _ _ _ _ _ _ _ _

1. CABLE LENGTH (km)


2. No. of SPLICE (pcs)
3. No. of CONNECTOR (pcs)
5. SPLITTER 1:8 (1 pc)
ATTENUATION LIMITATION (dB)

CABLE LENGTH (km):

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 100
CopyrightFujikura Ltd./Y.N

O D P N o ._ _ _ _ _ _ _ _ _

HANDBOOK for
FTTH OSP (PT TELKOM INDONESIA)
2.2.9 FORM IV: Splice Loss Record

FORM : IV

STO

FEEDER CABLE A

DATE OF MEASUREMENT

Seg.A(OTB-ODC_splitter) Splice Loss Measurement by Splicer

PT TELEKOMUNIKASI INDONESIA

DAERA

Sub Sistem : Feeder Cable

Measurement tools : Fusion splicer


Specification/limitation : 0.1 dB

FEEDER CABLE B

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

96

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

79

78

77

76

75

74

73

72

71

70

69

68

67

66

65

64

63

62

61

60

59

58

57

56

55

54

53

52

51

50

49

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

144

143

142

141

140

139

138

137

136

135

134

133

132

131

130

129

128

127

126

125

124

123

122

121

120

119

118

117

116

115

114

113

112

111

110

109

108

107

106

105

104

103

102

101

100

99

98

97

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

192

191

190

189

188

187

186

185

184

183

182

181

180

179

178

177

176

175

174

173

172

171

170

169

168

167

166

165

164

163

162

161

160

159

158

157

156

155

154

153

152

151

150

149

148

147

146

145

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

240

239

238

237

236

235

234

233

232

231

230

229

228

227

226

225

224

223

222

221

220

219

218

217

216

215

214

213

212

211

210

209

208

207

206

205

204

203

202

201

200

199

198

197

196

195

194

193

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

288

287

286

285

284

283

282

281

280

279

278

277

276

275

274

273

272

271

270

269

268

267

266

265

264

263

262

261

260

259

258

257

256

255

254

253

252

251

250

249

248

247

246

245

244

243

242

241

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

PASS

Fiber No.Loss (dB) PASS/FAIL Fiber No. Loss (dB) PASS/FAIL Fiber No. Loss (dB) PASS/FAIL Fiber No. Loss (dB) PASS/FAIL Fiber No. Loss (dB) PASS/FAIL Fiber No.Loss (dB) PASS/FAIL

48

Catatan: Splice Loss of Estimated Loss indicated by Fusion Splicer

HANDBOOK for FTTH-OSP v 1.0 (June 2013)


Page 101
CopyrightFujikura Ltd./Y.N

Anda mungkin juga menyukai