The first time you use the machine,you must connect well the current source,air resource and the vacuum
motor.Make it sure that it function well and then turn on circuit breaker and press the current switch .There are
details in the picture below .
Touch
screen
Vacuum
motor socket
The power
switch
Pressure
regulator
Automatic
start switch
Emergency stop
switch For
emergency stop
ONE:Parameters
ONE:
1 the input voltageAC 220V
2 the machine total powerabout 500W
3 Enter the total pressure0.45-0.6MP
4 the control voltageDC 24V
5 the working environmentfrom -3 to 40 Celsius
6 Machine size380*550*600
7 weight23KG
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
step
2.Unscrew
the oil filler cap and add special vacuum pump oil
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
Access
power
Open
switch
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
THREE:
danger
TP
Pressure
gauge
Emergency
stop button
Regulat
Start button
After
the
position X03
NOTE
Must be unscrewed before use
limit
X04
front
position
limit
Note: The least once a month air compressor oil pump position, if less than the
scale of the next cell, you must stop and put oil in!
Full oil
position
No oil
position
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
Four:
1.Boot screen
Exchange
Chinese
with
English
by
Click this
button to enter
the system
5
3
10
11
1
2
3
4
5
6
7
8
12
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
9 Click this button the electricity opportunities according to (3) the position
of the value forwardautomatic stop after arrival
10 Click this button to platform to move forward
11 Click this button to platform to back
12 Click the button to enter the abnormal information interface
Note: point before your device automatically returns to its original state! The
platform must in the middle, click Motor homing! Platform will return to the
original position!
3
4
5
10
6
12
7
11
1
2
3
4
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
4.Parameter Settings
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
(1)Click to clear the alarm,then the machine back to the initial state.
(2)Click to clear the alarm recording.
(3)Display alarm history record.
(4)show the alarm information of any moments..
Tips:Only under the condition of pressure can the machine work.If you want to return the
device to the its initialization,you must make sure that you press the stopping button(red
one)with pressure(let out the button in time)and then return .Only being operated in that
way will the machine work normally.
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
Temperature
Start Point
Distance
Speed
Remove Speed
ip4
50
46
96
45
ip5
50
46
104
45
ip6
50
42
120
45
ip6plus
50
27
130
45
Common abnormal
abnormal problems and treatment:
treatment:
1Click the button on the touch screen machines did not respond.
Solve methods
1Check the machine is powered and connected ventilation vacuum motor,
the specific operations, please refer to "new machine installed step"
2Check the emergency stop is pressed, if you press please unscrew!
Then press the reset and try again!
3Disassemble the machine table cover, look at the back of the touch
screen plug is loose, then plug by hand tight! See "disassemble step"
2In automatic mode, the temperature of the mold is not!
Solve methods
First, the temperature is set high, view the heating relay lamp is lit,
replace the relay does not shine. Bright replacement of heating
rods. See "disassemble step"
3, In manual mode, the automatic mode can not play, point stepping forward, stepping
back, motor homing buttons do not respond.
Solve methods
Turn off the power, re-open, and then click on the Forward button in
the manual interface, so the heating plate mold machine under went
to the middle, then back to the origin or the normal operation of
the press can automatically!
4In manual mode, the automatic mode can not enter
Solve methods
Check vacuum motor, motor speed and cylinder button is pressed,
please press the reset if you can!
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
5In manual mode, point vacuum motor or speed motor or cylinder buttons do not
respond.
Solve methods
1Point vacuum motor does not respond: Check vacuum motor power cord is
plugged in, or plug position. Vacuum tube is connected!
2.Point speed motor did not respond: speed control motor speed motor relay
broken or bad damage!
3Point cylinder Button does not respond: Check whether the air supply
connected. If you did not take a good response, indicating that the solenoid
valve is broken!
SIX
SIXEASY BROKEN PARTS MOULD
PLC+TP
EX2N-43H-18MRT-2AD-1P-S
Jog buttons
LA167-D8-11
Emergency button
LA167-D8-11ZS
Select button
Switching Power
Supply
LA167-D8-11X/2
SM2425DA
Disconnect Switch
DZ47-60 C16 2P
RS-100-24
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
Disassemble step
Unload TP 1
Unload TP 2
Switching Power
Motor
Driver
Vacuum,
heating
and
motor control
relay
Solenoid
valve
Heater
Temperature
sensor
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com
Vacuum
connection
Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store
Tel: +86 13528895042
Mail: Sales@xicart.com
Skype: sales.xicart
Website: www.xicart.com