F L O O R
LinkBuilder Hub
Configuration
Guide
STATUS
UNIT
3C1666
LinkBu
FMS ilder
II
-2
LinkBu
FMS ilder
II Tel
co
3C1667
STATUS
UNIT
3C1667
LinkBu
FMS ilder
II
LinkBu
FMS ilder
II
STATUS
UNIT
3C1667
S E C O N D
F L O O R
ilder
LinkBu
FMS II
1
3C1667
UNIT
STATUS
F I R S T
F L O O R
Table of Contents
Decision Tree for 3Com LinkBuilder Hubs
21
10
12
14
16
18
19
Intelligent Switches
21
22
24
Management
Requirements
High-performance/high-traffic
switched LAN or workgroup
Media/Connections
Module Options
No
LinkBuilder TP/8
3C16180
10BASE-T/RJ-45
None
No
No
LinkBuilder TP/12
3C16170
12
10BASE-T/RJ-45
Bridge MicroModule
Transceiver Interface Modules
Yes
No
LinkBuilder TP/8i
3C16181
10BASE-T/RJ-45
Bridge MicroModule
Transceiver Interface Modules
Yes
and
No
Yes
LinkBuilder FMS II
3C16670 (12-port TP)
3C16671 (24-port TP)
3C16665 (6-port Fiber)
3C16672 (24-port Telco)
LinkBuilder FMS
3C1625-0 (10-port Coaxial)
12
24
6
24
Management Module
10BASE-T/RJ-45
Bridge Management Module*
10BASE-T/RJ-45
Bridge MicroModule
10BASE-FL/ST
Transceiver Interface Modules
10BASE-T/Two 50-pin Telco
10
BNC
LinkBuilder FMS TR
3C510500 (12-port)
12
3C510501 (24-port)
24
Yes
RMON Management
Advanced RMON Management
Copper/Fiber RI/RO
Yes
Yes
LinkBuilder MSH
3C18040 (Chassis)
Up to 240
(Ethernet)
up to 108
(Token Ring)
up to 54
(FDDI)
No
No
No
No
Yes
No
LinkBuilder TP/8
3C16180
LinkBuilder TP/12
3C16170
LinkBuilder TP/8i
3C16181
Yes
Yes
LinkBuilder FMS II
Yes
Yes
LinkBuilder FMS TR
Yes
Yes
SuperStack System
LinkBuilder FMS II
Yes
No
Yes
Number
of Ports
No
Yes
Support for
Mixed Media Product Name and Part No.
Yes
LinkBuilder MSH
3C18041 (Chassis with
FDDI backplane)
10BASE-T/Telco
10BASE-T/RJ-45
10BASE-FL/ST
10BASE-2/BNC
TR Lobe UTP/RJ-45
TR Lobe STP/RJ-45
TR RI/RO STP/DB-9
TR RI/RO Fiber/ST
FDDI/MIC
CDDI/RJ-45
Management Module
Ethernet Bridge Module
Token Ring Bridge Module
Token Ring RMON Module
Media Modules
Transceiver Interface Modules
10BASE-T/RJ-45
None
12
10BASE-T/RJ-45
10BASE-T/RJ-45
Bridge MicroModule
Transceiver Interface Modules
Bridge MicroModule
Transceiver Interface Modules
RMON Management
10BASE-T/100BASE-T
100BASE-TX
100BASE-FX
10
10BASE-T/RJ-45
None
24
10BASE-T/RJ-45
100BASE-T/RJ-45
10BASE-T/RJ-45
SAS Fiber MIC
10BASE-T/RJ-45
SAS Fiber MIC
10BASE-T/RJ-45
155 Mbps OC-3c/SC or
45Mbps DS-3/BNC
10BASE-T/Telco
10BASE-T/RJ-45
10BASE-FL/ST
10BASE-2/BNC
TR Lobe UTP/RJ-45
TR Lobe STP/RJ-45
TR RI/RO STP/DB-9
TR RI/RO Fiber/ST
FDDI/MIC
CDDI/RJ-45
Management Module
Ethernet Bridge Module
Token Ring Bridge Module
Token Ring RMON Module
LinkSwitch 1200 Module
Media Modules
Transceiver Interface Modules
6
16
12
Up to 240
(Ethernet)
up to 108
(Token Ring)
up to 54
(FDDI)
Hubs
Switches
Routers
Remote Access
Servers
SNA-to-LAN
Converters
Redundant
Power System
Network
Management
Software
Backbone
The SuperStack
Advantage
WAN/SNA Host
Solution 1:
Managed Ethernet Connectivity
Requirements
Corporate Headquarters
Highlights
The large departmental workgroup at
the central site is an ideal application
for the powerful LinkBuilder MSH
hub. The LinkBuilder MSH is 3Coms
most advanced, fault-tolerant floor
distribution concentrator, providing
high port density, resilient links, and
hot-swappable modules for maximum
uptime in mission-critical applications. A single management module
provides SNMP-based Transcend
management for the entire hub.
al Sit
Centr
r II
m
uilde
r Roo
NETB
mpute
in Co
STATUS
LinkBuilder
FMS II
3C16670
UNIT
green = link OK
Red = Partition
off
= link fail
Red = Partition
MDI
MDIX
10
11
12
TCVR
Packet
Power
AUI
Collision
MGMT
LinkBuilder
FMS II
3C16671
UNIT
STATUS
Red = Partition
MDI
10
11
12
TCVR
Packet
Power
MDIX
13
14
15
16
17
18
19
20
21
22
23
24
AUI
Collision
MGMT
Send
10BT
Link
Active
+/-
Fault
10-Base T
LinkBuilder
Remote Office
SYSTEM
WAN INTERFACES
Link
Fiber
emote
R
Large
Offic
Active
Fault
Console
AUI
RS-449 (B)
RS-232 (C)
Status
INPUT
Reset
Fwd Power/
Fault
3C565047
Redundant Power Supply
LinkBuilder
RPS
OUTPUT
Fault
Overtemp
OK
)
2-Port
)
S II (1
4-Port
er FM
d
(2
il
2
II
u
FMS
ice 22
LinkB
ilder
te Off
u
o
B
m
k
e
Lin
stem
rR
y
e
S
d
r
il
e
u
t Pow
NETB
ndan
Redu
Products
LinkBuilder FMS II 12-Port TP Hub
(3C16670)
LinkBuilder FMS II 24-Port TP Hub
(3C16671)
LinkBuilder FMS II Management Module
(3C16630)
NETBuilder Remote Office 222 (3C8222)
Redundant Power System (3C565047)
r MS
uilde
LinkB
Security: Defending
Data and Resources
Products
LinkBuilder MSH Chassis with FDDI
Backplane (3C18041)
LinkBuilder MSH 525W Power Supply Unit
(3C18012)
LinkBuilder MSH 24-Port 10BASE-T
Repeater Module (3C18122A)
LinkBuilder MSH 13-Port 10BASE-T
Repeater Module (3C18120A)
LinkBuilder MSH 7-Port 10BASE-T
Repeater Module (3C18124A)
LinkBuilder MSH Management Module
(3C18500)
rkgro
l Wo
Loca
Small
ice
ite Off
Satell
Stand-alone encryption systems that provide the same protection are expensive
and relatively difficult to implement, and
can adversely affect network performance.
i
20
r TP/8
ffice
uilde
ote O
LinkB
r Rem
uilde
B
T
E
N
STATUS
3C16181
STATUS
green = link OK
Red = Partition
off
= link fail
MDIX
Red = Partition
1
LinkBuilder
TP/8i
green = link OK
Red = Partition
off
= link fail
MDI
4
TCVR
Packet
Power
Collision
MGMT
Products
LinkBuilder TP/8i Hub (3C16181)
NETBuilder Remote Office 201 (3C8201)
Solution 2:
Managed Token Ring Connectivity
Requirements
Products
LinkBuilder FMS TR 12-Port Hub (3C510500)
LinkBuilder FMS TR 24-Port Hub (3C510501)
LinkBuilder FMS TR RMON Management
Agent Module (3C510502)*
LinkBuilder FMS TR Advanced RMON
Management Agent Module (3C510505)*
LinkBuilder FMS TR Copper RI/RO Module
(3C510504)*
LinkBuilder FMS TR Fiber RI/RO Module
(3C510503)*
LinkBuilder FMS TR Copper/Fiber RI/RO
Module (3C510506)*
8-Foot Redundant Ring Cascade Cable
(3C510508)
Redundant Power System (3C565047)
*For the 12-port hub only
Configuring the
LinkBuilder MSH
in a Token Ring
Environment
Bridged Token Ring with LinkBuilder MSH
Highlights
Products
LinkBuilder MSH Chassis with FDDI
Backplane (3C18041)
LinkBuilder MSH 525W Power Supply Unit
(3C18012)
LinkBuilder MSH Fiber RingBuilder
Modules (3C18240)
LinkBuilder MSH Advanced MAU Module
(3C18202)
LinkBuilder MSH 2-Port Token Ring Bridge
Module (3C18620)
LinkBuilder MSH Management Module
(3C18500)
Token Ring
path connections
2-Port Bridge
Module
RingBuilder
Modules
RI/RO to 4 Mbps
Token Ring backbone
Solution 3:
Building a Resilient Network
Requirements
To switch
(secondary)
To switch
(primary)
Management
Module
13-Port 10BASE-T
Module
24-Port 10BASE-T
Module
PC
PC
PC
SuperStack Configuration
Products
LinkBuilder MSH Chassis with FDDI
Backplane (3C18041)
2X LinkBuilder MSH 525W Power Supply
Units (3C18012)
LinkBuilder MSH 13-Port 10BASE-T
Repeater Module (3C18120A)
LinkBuilder MSH 24-Port 10BASE-T
Repeater Module (3C18122A)
LinkBuilder MSH Management Module
(3C18500)
Fiber-Optic Transceiver Interface Module
(3C1206-5)
Highlights
Products
LinkBuilder FMS II 24-Port TP Hub
(3C16671)
LinkBuilder FMS II Telco Hub (3C16672)
LinkBuilder FMS II Fiber Hub (3C16665)
LinkBuilder FMS II Bridge Management
Module (3C16040)
cally sent to the management console. The system also has redundant
fans and LED temperature indicators
to protect against failures caused by
overheating.
Rx
Rx
loss
Tx
Solution 4:
Bridging and LAN Segmentation
Requirements
Relocate a computer-aided
design (CAD) department
requiring two separate network
segments to the same floor as a
department running NetWare.
LAN traffic on all three networks must remain separate,
while still allowing for interconnections between the departments and the fiber backbone.
Fiber backbone
Management
Module
3 Ethernet
backplanes
UTP Modules
10
4-Port Bridge
Module
LAN Extension
Highlights
Products
Products
LinkBuilder FMS II 24-Port TP Hub
(3C16671)
LinkBuilder FMS II Telco Hub (3C16672)
LinkBuilder FMS II Fiber Hub (3C16665)
NetWare users
NetWare
department
server
CAD workstations
CAD
server
CAD workstations
Rx
Rx
loss
Tx
CAD
server
11
Solution 5:
LAN Switching and High-Speed Connectivity
Requirements
Products
LinkBuilder MSH Chassis with FDDI
Backplane (3C18041)
LinkBuilder MSH 525 Power Supply Unit
(3C18012)
LinkBuilder MSH 24-Port 10BASE-T
Repeater Module (3C18122A)
LinkBuilder MSH FDDI Fiber-Optic Module
(3C18300)
LinkBuilder MSH FDDI RingBuilder Module
(3C18310)
LinkBuilder MSH LinkSwitch 1200 Module
(3C18640)
FDDI MIC Media Module (3C18320)
LinkBuilder MSH LinkSwitch Expansion
Module (3C18645)
LinkBuilder MSH Management Module
(3C18500)
Standard
workstations
High-performance
workstations
FDDI backbone
FDDI servers
12
LinkSwitch: A
Switching Revolution
in the Workgroup
SuperStack Workgroups with LAN Switching
Highlights
Products
LinkBuilder FMS II 24-Port Hub (3C16671)
LinkBuilder FMS II Fiber Hub (3C16665)
LinkSwitch 500 (3C30500) or
LinkSwitch 1000 (3C16900) or
LinkSwitch 1200 (3C16640) or
LinkSwitch 2200 (3C220000)
(Shown below) or
LinkSwitch 2700 (3C32730) with OC-3c
LinkBuilder FMS II Management Module
(3C16630)
Redundant Power System (3C565047)
STATUS
3C16671
UNIT
LinkBuilder
FMS II
Red = Partition
MDI
10
11
12
TCVR
Packet
Power
MDIX
13
14
15
16
17
18
19
20
21
22
23
24
AUI
Collision
MGMT
STATUS
2
10
11
12
STATUS
A
10
11
12
14
15
10
11
Packet
Power
AUI
Collision
MGMT
LinkSwitch
2200
16
Serial Port
TCVR
STATUS
13
FDDI
12
10
11
12 1 3
14
15
16
ETHERNET
3C565047
Redundant Power Supply
INPUT
LinkBuilder
FMS II
Red = Partition
3C16665
UNIT
green = link OK
Red = Partition
off
= link fail
LinkBuilder
RPS
OUTPUT
Fault
Overtemp
OK
Fast Ethernet
LinkSwitch
500
LinkSwitch
100 0
LinkSwitch LinkSwitch
1200
2200
Lowest price/port
and entry price
24 RJ-45 UTP ports
500 MAC addresses*
Forwarding mode
Cut-through and
Store and Forward
2 Fast Ethernet ports
*Unlimited on the downlink
ATM
FDDI
LinkSwitch
2700
Lowest Ethernet/
ATM price/port
12 RJ-45 UTP ports
8,192 MAC addresses
Forwarding mode
Cut-through and
Store and Forward
PerformancePowerful switching
engines extend full 10 Mbps bandwidth to the workgroup and up to
155 Mbps to the server or backbone,
eliminating network bottlenecks.
SimplicityPlug-and-play installation and drag-and-drop graphical
configuration make adds, moves,
and changes exceptionally easy.
13
LinkBuilder MSH
LinkBuilder MSH is a multi-services
hub that can support up to 10 managed Ethernet, 5 managed Token Ring,
or 3 managed FDDI workgroups over
diverse media types.
The LinkBuilder MSH offers outstanding reliability and fault tolerance.
Each Ethernet connectivity module
has its own repeater, so a failure in one
module cant bring down the others.
Automatic resilient links ensure reliability and maximize uptime, and all
connectivity modules and power
supplies are hot-swappable, including fans.
The Ethernet bridge module
provides the hub with affordable
segmentation to boost performance
on the floor. For high-speed floor
connectivity, FDDI concentrator
modules support FDDI using MIC
connectors and CDDI using RJ-45
connectors. FDDI RingBuilder modules build a single FDDI ring from
multiple FDDI concentrator modules.
In Token Ring LANs, the
LinkBuilder MSH features PhaseLocked Loop retiming for reliable signals over larger rings, and Zero Delay
Lockout and Advanced Distributed
Recovery Intelligence to isolate faulty
stations from the network.
The LinkBuilder MSH hub
includes integrated support for
Ethernet RMON network management. RMON agents and ASICs on
each connectivity module collect and
compile RMON data, providing powerful monitoring capabilities for every
segment on the network. Because
RMON intelligence is integrated into
the connectivity modules, RMON
functionality scales easily as your
network grows. An RMON module
is also available for Token Ring.
A single management module
manages the entire multi-technology
hub. Using 3Coms Distributed
14
MANAGEMENT
3C18500
ETHERNET MODULES
3C18120A 3C18121A 3C18122A 3C18124A 3C18135A 3C18140A
HUB CHASSIS
Modules
POWER
BRIDGING
EXPANSION MODULES
3C18136
3C18141
3C18600 3C18620
3C18146
FDDI CONNECTIONS
3C18300
3C18301
3C18310
SWITCHING
3C18320
3C18640 3C18645
Connections for six single-attached workstations via UTP FDDI RJ-45 connectors.
15
LinkBuilder FMS II
LinkBuilder FMS II stackable hubs
provide media flexibility, manageability, and economy, with an unbeatable list of features that includes
bridging, built-in resilient links, and
optional redundant power supplies.
With LinkBuilder FMS II, you
create a single- or mixed-media
Ethernet stack with 12-port and
24-port RJ-45 twisted-pair, 24-port
Telco twisted pair, and 6-port ST
fiber hubs. You can also integrate the
LinkBuilder FMS coaxial hub with
a LinkBuilder FMS II mixed media
stack. These hubs keep your initial
investment low, letting you increase
port density and add bridging and
comprehensive SNMP management
when you need it.
LinkBuilder FMS II hubs work
with 3Coms innovative SuperStack
systems, allowing you to easily integrate hubs, bridges, routers, switches,
and redundant power, managing
them as a single system.
Hubs
12-Port TP Hub (3C16670)
Provides 12 shielded RJ-45 twisted-pair
connectors, along with a standard AUI
port or a slot for a slide-in transceiver
interface module.
Fiber Hub (3C16665)
Provides six ST fiber connectors, along
with a standard AUI port and a slot for a
slide-in transceiver interface module.
3C16670
3C16672
3C16665
3C16671
Transceiver Interface
Module for backbone
connections (BNC,
ST Fiber, TP, AUI)
LinkBuilder
Bridge
MicroModule
Separate resilient
power supply
LinkBuilder FMS II Stack (back view)
16
Expansion
cable
Standard
AUI port
Modules
Management Module (3C16630)
User-installable SNMP module that
can be added to any hub in the stack
at any time. A single module manages the entire stack, supporting inband management from an SNMP
management station over IP or IPX,
via a telnet session, or out-of-band
using the local port, a modem, or
Serial Line Interface Protocol (SLIP)
over a remote serial connection.
Bridge Management Module
(3C16040)
User-installable module that provides local bridging, bridge management, and hub management for all
LinkBuilder FMS II hubs. Lets you
segment the network, manage both
hub and bridge operation, and run
Spanning Tree Algorithm (STA) for
redundant links.
Diagram A
LinkBuilder FMS
Management Module
(3C16030)
1. LinkBuilder FMS
2. LinkBuilder FMS
3. LinkBuilder FMS
4. LinkBuilder FMS II
5. LinkBuilder FMS II
6. LinkBuilder FMS II
7. LinkBuilder FMS II
8. LinkBuilder FMS II
Power Options
Redundant Power System
(3C565047)
Provides two load-sharing bulk
power supplies fed by independent
AC lines. Either of the two supplies
can support up to four LinkBuilder
FMS II hubs or other units in a
SuperStack system.
Diagram B
LinkBuilder Bridge
MicroModule (3C16060)
LinkBuilder Hub Configuration Guide
17
LinkBuilder FMS TR
LinkBuilder FMS TR hubs combine
RMON-based management with the
most advanced physical layer support
in an affordable, expandable platform
for mission-critical Token Ring
networks.
The hubs provide an array of
Token Ring features unmatched in
the industryincluding advanced
Zero Delay Lockout and Distributed
Recovery Intelligence error recovery
and fault isolation technologies,
Phase-Locked Loop retiming mechanisms, and sophisticated SNMP
RMON network management.
For connectivity in a central wiring
closet, cascade connectors can link up
to 20 hubs in one rackup to 260
users in all. Ring In/Ring Out modules allow main ring connections to
20 hubs in different locations up to
660 feet (200 meters) apart.
LinkBuilder FMS TR is part of
3Coms innovative SuperStack system, allowing you to easily integrate
hubs, bridges, routers, switches, SDLC
conversion devices, and redundant
power into a single, manageable stack.
Modules
RMON Management Agent Module
(3C510502)
User-installable SNMP RMON module
that adds a network analyzer level of
management to the LinkBuilder FMS
TR hubs. Slides into the LinkBuilder
FMS TR 12-port hub only; includes
an RS-232 DB-9 serial port.
Advanced RMON Management Agent
Module (3C510505)
User-installable SNMP RMON
module that supports all ten groups of
the Token Ring RMON specification.
Slides into the LinkBuilder FMS TR
12-port hub only; includes an RS-232
DB-9 serial port.
Fiber RI/RO Module (3C510503)
Slide-in module providing Ring In/Ring
Out expansion to multiple wiring closets.
Module has two pairs of fiber ST connectors and slides into the LinkBuilder
FMS TR 12-port hub only.
Accessories
Hub Expansion Cascade Cable (spare)
(3C510507)
8-Foot Redundant Ring Cascade Cable
(3C510508)
Power Options
Redundant Power System (3C565047)
Provides two load-sharing bulk power
supplies fed by independent AC lines.
Either of the two supplies can support
up to four LinkBuilder FMS TR hubs
or other units in a SuperStack system.
3C510500
Hubs
12-Port Hub (3C510500)
Provides 13 RJ-45 twisted-pair ports,
along with two DB-15 cascade connectors and a cascade cable. Hub has slots
for management and RI/RO expansion
modules.
3C510501
3C565047
18
Fixed-Port Hubs,
Repeaters, and
Accessories
Fixed-Port Hubs
LinkBuilder TP/8i Hub (3C16181)
Standalone 10BASE-T hub designed
for small remote offices with a requirement for SNMP management. Supports
up to eight twisted-pair ports via RJ-45
connections, with an optional, modular backbone port. Features built-in
SmartAgent management and support
for local bridging using the LinkBuilder
Bridge MicroModule. Backed by a lifetime warranty, the LinkBuilder TP/8i
is a robust entry point for reliable, managed 10BASE-T networking.
LinkBuilder TP/12 Hub (3C16170)
Unmanaged, standalone workgroup hub
providing 12 shielded RJ-45 twisted-pair
connectors, along with a slot for optional
transceiver interface modules for backbone connections. The LinkBuilder
Bridge MicroModule (3C16060), which
fits into the transceiver interface slot,
provides unmanaged bridge functionality.
LinkBuilder TP/8 Hub (3C16180)
Unmanaged, standalone workgroup hub
providing eight shielded RJ-45 twistedpair connectors, along with a standard
BNC connector for backbone connections. Eighth port can be used as a
station port or for cascading multiple
hubs on the same segment. Power supplied from external AC power source.
Repeaters
ISOLAN TRANSCEIVERS
Accessories
19
CABLES
100 m maximum
segment length.
Hub can have
RJ-45 or
Telco RJ-21
connectors.
10BASE-5
(Coaxial,
needs
transceiver
link to hub)
500 m maximum
segment length.
100 transceivers
per segment.
2.5 m transceiver
spacing. Absolute
maximum of 3 km
DTE to DTE
path length.
Ethernet Cabling
10BASE-T
(Twisted Pair)
Fiber Optic
10BASE-FL
(fiber link)
supports
2 km over
62.5 m cable.
Maximum
of 4 km DTE
to DTE path.
Active Token
Ring
Token Ring
Expansion
(B) Category 3
UTP at 4 Mbps
(660 ft/200 m)
or 16 Mbps
(330 ft/100 m)
(B) Category 4 or
5 UTP at 4 Mbps
(1320 ft/400 m)
or 16 Mbps
(660 ft/200 m)
(A) Type 1 STP
on 4 Mbps
(2000 ft/600 m)
or 16 Mbps
(1000 ft/300 m)
20
Intelligent Switches
3Com switches enhance your networks performance by creating
microsegments that are interconnected using a high-speed switching
matrix. Microsegmenting means that
a switched node doesnt share bandwidth with other nodes, even when
they share the same portwhich
translates to dramatic increases in
performance.
3Com leads the industry in breadth
of switching offerings with a total of
three product families: LinkSwitch,
LinkSwitch Family
LANplex Family
CELLplex Family
21
22
Part No.
Environment
Technologies
Supported
Maximum
Switched Ports
LinkSwitch 500
3C30500
Workgroup
Ethernet (10BASE-T)
10 Ethernet
Yes
LinkSwitch 1000
3C16900
Workgroup
Ethernet (10BASE-T)
Fast Ethernet
(100BASE-FX
or 100BASE-TX)
24 Ethernet
1-2 Fast Ethernet
Yes
100BASE-FX
Downlink Module,
Transceiver
Interface Module
LinkSwitch 1200
3C16640
Workgroup
Ethernet (UTP)
FDDI (fiber MIC)
6 Ethernet
1 FDDI (DAS)
Yes
LinkSwitch 1200
Module for MSH
3C18640
Workgroup
Ethernet (backplane)
FDDI (fiber MIC)
3 Ethernet
1 FDDI
No
3C18645
Workgroup
Ethernet (10BASE-T)
6 Ethernet
No
LinkSwitch 2200
3C220000
Workgroup
Ethernet (10BASE-T)
FDDI (fiber)
16 Ethernet
1 FDDI (DAS)
Yes
LinkSwitch 2700
3C32701
Workgroup
Ethernet (10BASE-T)
ATM (with OC-3c
155 Mbps or with
DS-3 45 Mbps)
12 Ethernet
1 ATM
Yes
LANplex 2016
3C201610
(1 power
supply)
Workgroup
Ethernet (10BASE-T,
10BASE-FL, 10BASE-2,
10BASE-5)
16 Ethernet
No
3C201620
(2 power
supplies)
Workgroup
Ethernet (10BASE-T,
10BASE-FL, 10BASE-2,
10BASE-5)
16 Ethernet
No
Technologies
Supported
Maximum
Switched Ports
Department
Ethernet (10BASE-T,
10BASE-FL, 10BASE-2,
10BASE-5)
FDDI (UTP, fiber)
16 Ethernet
2 FDDI/CDDI
No
FDDI Multimode
Optical Bypass
Switch
3C250200
(2 power
supplies)
Department
Ethernet (10BASE-T,
10BASE-FL, 10BASE-2,
10BASE-5)
FDDI (UTP, fiber)
16 Ethernet
2 FDDI/CDDI
No
FDDI Multimode
Optical Bypass
Switch
3C6012-001
(12 slots,
1 power
supply)
Data
center
Ethernet (10BASE-T,
10BASE-FL, AUI,
10BASE-2)
FDDI (UTP, fiber)
Token Ring (STP)
Depends on
configuration
No
Ethernet Switching,
Ethernet/FDDI
Switching, FDDI
Concentration,
Token Ring Switching
3C6012-002
(12 slots,
2 power
supplies)
Data
center
Ethernet (10BASE-T,
10BASE-FL, AUI,
10BASE-2)
FDDI (UTP, fiber)
Token Ring (STP)
Depends on
configuration
No
Ethernet Switching,
Ethernet/FDDI
Switching, FDDI
Concentration,
Token Ring Switching
3C6004-001
(12 slots,
1 power
supply)
Data
center
Ethernet (10BASE-T,
10BASE-FL, AUI,
10BASE-2)
FDDI (UTP, fiber)
Token Ring (STP)
Depends on
configuration
No
Ethernet Switching,
Ethernet/FDDI
Switching, FDDI
Concentration,
Token Ring Switching
3C6004-002
(12 slots,
2 power
supplies)
Data
center
Ethernet (10BASE-T,
10BASE-FL, AUI,
10BASE-2)
FDDI (UTP, fiber)
Token Ring (STP)
Depends on
configuration
No
Ethernet Switching,
Ethernet/FDDI
Switching, FDDI
Concentration,
Token Ring Switching
CELLplex 7000
3C37000
Campus and
building
backbone
16 ATM
No
CELLplex 7200
3C37200
Department
Ethernet (10BASE-T)
ATM (with OC-3c
155 Mbps or with
DS-3 45 Mbps)
48 Ethernet
and 4 ATM;
or 8 ATM
No
LANplex 2500
LANplex 6000
Part No.
Environment
3C250100
(1 power
supply)
23
SNMP-Based Network
Management That Cuts
Complexity
Transcend Network Management
Solutions
3Coms Transcend family of network
management applications solves the
challenges of configuring, troubleshooting, expanding, and securing
network resources for every device
in your networkincluding adapters,
hubs, switches, bridge/routers, and
remote access servers. Transcend products support a broad range of popular
management platforms: Microsoft
Windows, Sun Microsystems
SunNet Manager, HP OpenView,
IBMs NetView AIX and OS/2,
and Novells NMS. Transcend takes
management all the way down to
the desktop level, with hub-port-toadapter data correlation, PC asset
inventory and control, and the
ability to group devices according
to the managers priorities rather
than physical device connections.
This Product
LinkBuilder MSH
3C15010C
Windows 3.x
3C27850A
LinkBuilder FMS II
LinkBuilder TP/8i
LinkSwitch Switches
3C15010C
Windows 3.x
3C15000D
Windows 3.x
3C27850A
LinkBuilder FMS TR
3C15010C
Windows 3.x
3C15000D
Windows 3.x
3C27850A
24
3C512620
IBM OS/2
Notes
25
3Com Corporation
P.O. Box 58145
5400 Bayfront Plaza
Santa Clara, CA 95052-8145
Phone: 800-NET-3Com
or 408-764-5000
Fax: 408-764-6740
3Com ANZA
ANZA East
Phone: 61 2 959 3020
Fax: 61 2 956 6247
Belgium, Luxembourg
Phone: 32 2 716 4880
Fax: 32 2 716 4780
ANZA West
Phone: 61 3 9653 9515
Fax: 61 3 9653 9505
Netherlands
Phone: 31 3402 55033
Fax: 31 3402 54630
3Com Canada
Beijing, China
Phone: 8610 8492568
Fax: 8610 8492789
Calgary
Phone: 403 265 3266
Fax: 403 265 3268
Shanghai, China
Phone: 86 21 3740220
Ext. 6115
Fax: 86 21 3552079
Montreal
Phone: 514 874 8008
Fax: 514 393 1249
Hong Kong
Phone: 852 2501 1111
Fax: 852 2537 1149
Indonesia
Phone: 6221 523 9181
Fax: 6221 523 9156
Toronto
Phone: 416 498 3266
Fax: 416 498 1262
Vancouver
Phone: 604 434 3266
Fax: 604 434 3264
3Com Japan
Phone: 81 3 3345 7251
Fax: 81 3 3345 7261
3Com Latin America
U.S. Headquarters
Phone: 408-764-6075
Fax: 408-764-5730
Argentina
Phone: 541 312 8612
Fax: 541 313 5915
Spain
Phone: 34 1 3831700
Fax: 34 1 3831703
3Com Middle East
Phone: 971 4 349049
Fax: 971 4 349803
Chile
Phone: 562 633 9242
Fax: 562 633 4338
3Com Nordic AB
Colombia
Phone: 571 218 3933
Fax: 571 226 9770
Mexico
Phone: 525 531 0591
Fax: 525 254 3159
3Com European HQ
Phone: 44 1628 897000
Fax: 44 1628 897041
Malaysia
Phone: 60 3 233 6162
Fax: 60 3 233 6174
3Com France
Phone: 33 1 69 86 68 00
Fax: 33 1 69 07 11 54
Miami, Florida
Phone: 305-261-3266
Fax: 305-261-4901
Singapore
Phone: 65 538 9368
Fax: 65 538 9369
3Com GmbH
Venezuela
Phone: 582 261 0710
Fax: 582 261 5257
Germany
Phone: 49 89 627320
Fax: 49 89 62732233
Rome, Italy
Phone: 39 6 5917756
Fax: 39 6 5918969
Brazil
Phone: 55 11 546 0869
Fax: 55 11 247 7399
Korea
Phone: 822 732 4434
Fax: 822 732 4437
Taiwan
Phone: 886 2 377 5850
Fax: 886 2 377 5860
3Com Mediterraneo
Milano, Italy
Phone: 39 2 253011
Fax: 39 2 27304244
Sweden
Phone: 46 8 632 91 00
Fax: 46 8 632 09 05
Norway
Phone: 47 22 18 40 03
Fax: 47 22 18 23 85
Denmark
Phone: 45 33 37 71 17
Fax: 45 33 32 43 70
Finland
Phone: 358 0 435 420 67
Fax: 358 0 435 422 00
3Com South Africa
Phone: 27 11 803 7404/5
Fax: 27 11 803 7411
3Com UK Ltd.
Poland
Phone: 48 2 6451351
Fax: 48 2 6451352
Buckinghamshire
Phone: 44 1628 897000
Fax: 44 1628 897003
Switzerland
Phone: 41 31 9984555
Fax: 41 31 9984550
Manchester
Phone: 44 161 873 7717
Fax: 44 161 873 8053
3Com Ireland
Phone: 353 1 820 7077
Fax: 353 1 820 7107
1995, 3Com Corporation. All rights reserved. 3Com is a publicly owned corporation (NASDAQ:COMS). 3Com, Boundary Routing, LANplex, LinkBuilder, NETBuilder, NETBuilder II, SmartAgent, and
Transcend are registered trademarks and CELLplex, FMS, LinkConverter, LinkSwitch, MSH, RingBuilder, and SuperStack are trademarks of 3Com Corporation. Novell and NetWare are registered
trademarks of Novell, Inc. SunNet is a trademark of Sun Microsystems, Inc. IBM, NetView, and OS/2 are registered trademarks of International Business Machines Corporation. HP and OpenView
are registered trademarks of Hewlett-Packard Company. Windows is a trademark of Microsoft Corporation.
Printed in Canada.
100209-001 8/95