Anda di halaman 1dari 2

1.

A simply supported beam in the diagram below is carrying


a uniformly distributed characteristic load; dead load and
imposed loads of 5KN/m each as well as characteristic
imposed load of 30KN at midspan. Assuming the beam is
fully restrained, design the universal beam in grade S275
steel to satisfy the bending, shear and other conditions.
Assume the beam sits on a 100mm bearing at each end.

2. Design a compound beam to carry a uniformly distributed


dead load of 400KN and imposed load of 600KN. The
beam is simply supported and has a span of 11m. Allow
for self weight of 30KN for the beam. The overall depth of
the beam should not exceed 700mm. The lenght of the
stiff bearing at the ends is 216mm when thebeam is sitted
on a 20320371 UB. Full lateral support is provided for
compression flange. Design using a steel grade of S275.
3. Design a suitable column section in grade S275 steel to
support a factored axial concentrated load of 2000KN and
a factored BM of 100KNm about the major axis and
20KNm about the minor axis applied at the top of the
column. The column is 10m long and is fully fixed against
rotation @ the top and bottom and the floors that it
supports are braced against sway.
4. Determine the compression resistance of a column shown
in the diagram below if the effective length of the column
is 8m and the steel is S275

5. A proposed 5m long internal column in a rigid jointed steel


structure is concentrically loaded with 1000KN dead load
and 1000KN imposed load. Assuming fixity at the top and
bottom of the column gives effective rotational restraints.
Design the column.
6. Determine the compression resistance of a steel section
20320352 UC which is to be used as an encased
column. The column is an internal column in a multistorey
structure with an actual length of 4.2m centre to centre.
Assume grade S275 steel and grade 25 concrete.
7. A column consisting of 305305195 UC carries an axial
load of 1600KN and axial imposed load of 800KN. Adopting
a square base, determine the sizes and thickness of base
plate required. Concrete cube strength is 25KN/m 2 design
for grade S275 steel.
8. A column base is subjected to a factored moment of
55KNm and a factored axial load of 780KN. If the column
section is 60360386 Kg/m UC and the cube strength of
concrete in the foundation is 25N/mm 2, design a slab base
and web connection for the column and the base plate.
Assume that the material is machined for tight contact.
Use grade S275 steel.
9. A simply suuported plate girder has a span of 12m and
carry two concentrated load on the top flange at the third
points, consisting of 450KN dead load and 300KN imposed
load. In addition it carries a uniformly distributed dead
load of 20KN/m which includes an allowable for self weight
and an imposed load of 10KN/m. The compression flange
is fully restrained laterally. The girder is supported on a
heavy stiffened bracket at each end. Design the girder
using grade S275 steel

Anda mungkin juga menyukai