STANDARD COUNCIL GATE TYPE 1


Scale 1:50
200

30

80

NOTE:
1. Gate is to be constructed of
40mm square steel tubing
2mm thick min
2. All gate fittings to be
galvanised
3. Minimum gate width 3m

300 Cover

1200

170

Ground Level

nom

Strut Securely keyed


into corner post
1500

TOP VIEW
Scale 1:5

TYPICAL CROSS SECTION


Strut Securely
keyed into
Thrust Block
250
NOTE:
1. Gate is to be constructed of
33.7mm tubular steel
2.
All gate fittings to be
galvanised
3. Minimum gate width 3m

250

x 600 Long
Thrust Block

Scale 1:20
300 Cover

1200

170

Ground Level

GATE FASTENERS

nom (min)
2200

STANDARD COUNCIL GATE TYPE 2


Scale 1:50
APPLICABILITY TABLE

*Dimensions are in Millimetres unless otherwise shown

Capricorn Municipal
Development Guidelines

Council
BSC CHRC MRC
Yes
Yes
Applicable Yes

RRC
Yes

Steel Plate
See Detail A

300

Span as Specified
200

Fence with
Horizontal
Brace

15

Bend around
90 pin

2
150

Guide Post

40 min cover over


all reinforcing bars

150
Guide Post

345
12K1-S@200

Galv. Wires

300
1

7 / 24A1 - S

25

180
100

12S1-S@200
Guide Post

Guide Post

Stone
Pitching

BED RAIL

Bed Rail

200
Bend around
60 pin

260
450

2x Holding down bolts


at each end of all bearers

24 A1 bars (lapped
where necessary) are to
be continuous over the
length of abutments and
set parallel to the top.

ABUTMENT DETAIL 2
Scale 1:20

PLAN VIEW - 2.7m SPAN

ABUTMENT DETAIL 1

Scale 1:100

Scale 1:20

Welding to be in
accordance with
AS / NZS

1000

See Note 2

Galvanised Pipe
Horizontal BraceGalv. Pipe
Rail

3%

3%

Slope of Slab 1% min


100 thick Concrete
Slab with centrally
placed F82 Mesh

Compacted fill when slab


is above natural surface

100

Provide 6mm
Continuous Fillet Weld

Bearer

225

CROSS SECTION 1

WELDING DETAIL

Scale 1:75

Scale 1:10

30

180

30

Pavement

Pavement

240 x 65 x 16
Grade 250 to AS/NZS 3678
Hot Dip Galv. to AS/NZS 4680
Concrete slab to be
reinforced with SL62 Mesh

DETAIL A

CROSS SECTION 2
Scale 1:50

Universal beams
to be grade 250
to AS / NZS
3679.1

1000

To be 300 at point of
Bed Rail minimum clearence

Strainer Wire

Bolts Welded
to Plate See
Note 5
Steel Plate
See Detail A

NOTES:
1. Widths of Grid change depending on Road
Heirachy/ Category. For widths of grid refer to
Local Council's Grid Policy
2. All grids must have an accompanying gate. Refer
to Standard Drawing CMDG-G-017.
3. Dimensions are in millimeters unless otherwise
shown
4. Standard Grid Spans for 1.9 or 2.7m only
5. Holding down bolts M20 x 600, Grade 4.6, 70
thread with M20 nuts & locknuts, grade 5, galv. to
AS 1214 with NS washers.

Scale 1:10

APPLICABILITY TABLE

*Dimensions are in Millimetres unless otherwise shown

Capricorn Municipal
Development Guidelines

Council
BSC CHRC MRC
Yes
Yes
Applicable Yes

RRC
Yes