Anda di halaman 1dari 182

ITEM

NO

DESCRIPTION

UNIT

RATE EXCLUDING VAT

SECTION XIV- SCHEDULE OF TRANSPORT

Y-001

Y-002

Y-003

Y-004

Y-005

Transport of metal, sand,gravel and earth


beyond 10 km per km, rate for one cube.

km

Transport of cement beyond 10 km per km, rate


for one bag (50kg)

km

Transport of steel beyond 10 km per km, rate


for 1000kg.

km

Transport of bricks beyond 10 km per km, rate


for 1000Nos.

km

Transport of calicut tile beyond 10 km per km,


rate for 1000Nos.

km

A.) Head transport of materials:


Note:-

According to the head transport as per report of central provincial council price
committee 2014 .
Cement
A1. High steep areas (Nominal ground slope more than

20% ) Beyond 30 m , and there after every 100m or


it's portion

50kg

A2. Modarate Steep areas (Nominal ground slope 10% to

20% ) Beyond 30 m , and there after every 100m or


it's portion

50kg

A3. Flat areas (Nominal ground slope up to 10% )

Beyond 30 m , and there after every 100m or it's


portion

50kg

Sand , Metal and Soil


a.)

A4. High steep areas (Ground slope more than 20% )

Beyond 30 m , and there after every 100m or it's


portion

cu
b.)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES. KANDY .2014

Excluding VAT

RATE EXCLUDING VAT

102.00

1.02

20.40

51.00

51.00

f central provincial council price

0.05 X unskilled labour


rate per day.

0.03 X unskilled labour


rate per day.

0.02 X unskilled labour


rate per day.

Normal ground :3 X unskilled labour rate


per day
Difficult ground :4 X unskilled labour rate
Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES. KANDY .2014
per day

Excluding VAT

BUILDING SCHEDULE OF RATES EFFECTIVE FROM


2014 JANUARY
RATES EXCLUDING VAT

ITEM NO

DESCRIPTION

UNIT

SECTION I - MASONRY WORKS.


B-001

B-002

B-003

B-004

B-005

B-006

B-007

B-008

B-009

Brick work in 1:5 cement sand mortar 225mm thick and


above in foundations up to D.P.C .

m3

Brick work in 1:8 cement sand mortar 225mm thick in super


structure in ground floor.

m3

Brick work in 1:5 cement sand mortar 112.5mm thick in


ground floor.

m2

Brick work in 1:5 cement sand mortar 112.5mm thick using


available bricks.

m2

Brick work in 1:8 cement & sand mortar 225mm thick or


above. (using available bricks)

m3

Masonry block work 100mm thick in walls in cement and


sand 1:5 motar using hollow blocks made of cement and
sand to the proportion of 1:10, confirming to SLS standard in
ground floor.
Masonry block work 150mm thick in walls in cement and
sand 1:5 motar using hollow blocks made of cement and
sand to the proportion of 1:10, confirming to SLS standard in
ground floor.
Masonry block work 200mm thick in cement and sand 1:5
motar using hollow blocks made of cement and sand to a
proportion of 1:10, confirming to SLS standard in ground
floor.

m2

m2

m2

R.R masonry in 1:5 cement and sand motar in foundations


using available rubble.

m3

B-010

R.R masonry in 1:5 cement and sand motar in foundations.

m3

B-011

R.R masonry in 1:5 cement and sand motar in superstructure.


m3

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

UNIT

B-012

Provision of weep holes in retaining walls with 90mm dia.


PVC down pipes including metal packing around inner
mouth as directed, length of pipe up to 1050mm.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

UNIT

B-013

Provision of weep holes in retaining walls with 90mm dia.


PVC down pipes including metal packing around inner
mouth as directed, length of pipe 1200mm to 1650mm.

nr

Provision of weep holes in retaining walls with 90mm dia.


PVC down pipes including metal packing around inner
mouth as directed, length of pipe 1800mm to 2250mm.

nr

B-014

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

UNIT

SECTION II - CONCRETOR
C-001

C-002

C-003

C-004

C-005

C-006

C-007

C-008

C-009

Mixing and placing in position concrete grade 30, nominal


mix 1:1 :2 (20mm) using a concrete mixer including fuel /
operator / handling/vibrator.
Mixing and placing in position concrete grade 25, nominal
mix 1:1 1/2:3 ( 20mm) using a concrete mixer including
fuel / operator / handling/vibrator.
Mixing and placing in position concrete grade 20, nominal
mix 1:2:4 ( 20mm) using a concrete mixer including fuel /
operator / handling/vibrator.

m3

m3

m3

Mixing and placing in position concrete 1:21/2:5(25mm)


using a concrete mixer including fuel / operator /
handling/vibrator.

m3

Mixing and placing in position concrete 1:3:6 (40mm) using


a concrete mixer including fuel / operator / handling.

m3

Tor steel reinforcement bend to shape laid in position and tied


with G.I. wire as directed.

kg

Mild steel reinforcement bend to shape laid in position and


tied with G.I. wire as directed.

kg

Sawn timber formwork in class III timber for


ground floor.

m2

columns,

Sawn timber form work in class III timber for underside of


ground floor slabs.

m2

Sawn timber form work in class III timber for concrete


beams.

m2

C-011

Sawn timber formwork in class III timber for portal frames.

m2

C-012

Sawn timber formwork in class III timber for ground


concrete work,at ground level plinth beams,lintols etc.

m2

C-010

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

C-013

2400mm x 600mm x 450mm plat form with 75mm thick


1:3:6 (40mm) base & 2400mm x 300mm x 225mm step in
rubble and 75mm thick 1:2 1/2:5 (25mm) concrete topping.
Inclusive of 1:3 cement and sand rendering finished smooth
with coloured cement floating and polishing and providing
three numbers 2"dia.,4.5mm tk. G.I.pipe flag post complete
with painting and provide necessary arrangements for
hoisting the flag.

UNIT

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

C-014

Concrete catch pits / valve chambers in 50mm thick


1:2:4(20mm) concrete side walls and internal faces cement
rendered with 1:3 cement and sand finished smooth, to be
leak proof, inclusive of provision for necessary pipe
connection etc, with suitable cover or grating on top to be
flush with floor level. Internal dimensions 150mm x 150mm
x 300mm.

UNIT

nr
C-015

Concrete catch pits / valve chambers in 50mm thick


1:2:4(20mm) concrete side walls and internal faces cement
rendered with 1:3 cement and sand finished smooth, to be
leak proof, inclusive of provision for necessary pipe
connection etc, with suitable cover or grating on top to be
flush with floor level. Internal dimensions 150mm x 150mm
x 450mm.
nr

C-016

Concrete catch pits / valve chambers in 50mm thick


1:2:4(20mm) concrete side walls and internal faces cement
rendered with 1:3 cement and sand finished smooth, to be
leak proofed, inclusive of provision for necessary pipe
connection etc, with suitable cover or grating on top to be
flush with floor level. Internal dimensions 300mm x 300mm
x 450mm.
nr

C-017

Drain 225mm X 150mm(average depth) concrete 1:2 1/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm
crs 12mm thick , 1:3 cement sand rendering finished smooth,
including necessary excavation, form work, laying polythene
membrane under concrete and laid to required slope.
m

C-018

C-019

Drain 225mm X 300mm(average depth) concrete 1:2 1/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm
crs 12.5mm thick , 1:3 cement sand rendering finished
smooth, including necessary excavation, form work, laying
polythene membrane under concrete and laid to required
slope.

Drain 225mm x 450mm(average depth) concrete 1:2 1/2:5


(25mm) 75mm thick, provide expansion joints at 3000mm
crs 12.5mm thick , 1:3 cement sand rendering finished
smooth, including necessary excavation, form work, laying
polythene membrane under concrete and laid to required
slope.
m

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

ITEM NO

DESCRIPTION

C-020

750mm wide ramp and 225mm X 150mm(average depth)


drain in 1:2 1/2:5(25mm) concrete 75mm thick with 1:3
plaster finished smooth, including necessary excavation, form
work, providing expansion joints at 3000mm crs and laying
polythene membrane under concrete and laid to required
slope.

UNIT

m
C-021

C-022

C-023

C-024

C-025

Concrete cover slabs 50mm thick 1:2:4 (20 mm) r/f with,
6mm dia. MS bars at bottom @ 100mm centre. both ways,
1:3 cement and sand rendering finished smooth, pre-cast in,
pieces not exceeding 600mm x 450mm placed in position as
directed, providing drain holes if required.
Ready mixed concrete grade 20 , 1:2:4(20mm) pumping to
any level, rate including transporting, pumping, placing,
porker vibrating, levelling and curing the concrete. (Rate for
above 30m3 ) for Kandy area.
Ready mixed concrete grade 20 , 1:2:4(20mm) pumping to
any level, rate including transporting, pumping, placing,
porker vibrating, levelling and curing the concrete. (Rate for
above 30m3 ) for Gampola / Matale area.
Ready mixed concrete grade 20 , 1:2:4(20mm) pumping to
any level, rate including transporting, pumping, placing,
porker vibrating, levelling and curing the concrete. (Rate for
above 30m3 ) for Dambulla / Naula area.
Ready mixed concrete grade 20 , 1:2:4(20mm) pumping to
any level, rate including transporting, pumping, placing,
porker vibrating, levelling and curing the concrete. (Rate for
above 30m3 ) for Nawalapitiya area.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m3

m3

m3

m3

ITEM NO

DESCRIPTION

UNIT

SECTION III - DEMOLISHER


D-001

D-002

D-003

D-004

D-005

D-006

D-007

D-008

D-009

Ceiling asbestos removing including timber framework,


stacking serviceable materials and debris cleared away. in
single storied building.(Ceiling Only)
Ceiling asbestos removing including timber frame work,
stacking serviceable materials and debris cleared away in two
storied building. (Ceiling Only)

m2

m2

Partitions, weld mesh, shelves removed from existing walls


and stacking.

m2

225mm wide drain in brick masonry, demolishing and


clearing debris.

Floor paving brick, concrete or rubble inclusive of rendering


and debris cleared away.

m2

Corrugated sheets, iron, asbestos or aluminium alloy


removed from roof including frame work inclusive of wiring
and fixtures, gutters, valance boards etc.. in single story
buildings.

m2

Corrugated sheets, iron, asbestos or aluminium alloy


removed from roof including frame work inclusive of wiring
and fixtures, gutters, valance boards etc.. in two storied
buildings.
Corrugated sheets, iron, asbestos or aluminium alloy
removed from roof including frame work inclusive of wiring
and fixtures, gutters, valance boards etc.. in three storied
buildings.

m2

m2

Roof removing tiles with frame work inclusive of wiring and


fixtures, gutters, valance boards etc., stacking serviceable
material and debris cleared away in single storied buildings.
m2

D-010

Roof removing tiles with frame work inclusive of wiring and


fixtures, gutters, valance boards etc., stacking serviceable
material and debris cleared away in two storied buildings.
m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

10

ITEM NO

DESCRIPTION

D-011

Roof removing tiles with frame work inclusive of wiring and


fixtures, gutters, valance boards etc., stacking serviceable
material and debris cleared away in three storied buildings.

UNIT

m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

11

ITEM NO

DESCRIPTION

D-012

Tiles calicut or half round, removed from roof of single


storey buildings including stacking serviceable material and
debris cleared away.

D-013

D-014

D-015

D-016

D-017

D-018

D-019

D-020

Tiles calicut or half round, removed from roof of two storey


buildings including stacking serviceable material and debris
cleared away.
Tiles calicut or half round, removed from roof of three
storied buildings and above, including stacking serviceable
material and debris cleared away.

UNIT

m2

m2

m2

Removing and stacking trusses steel or timber 6.1m (20 L.ft)


of span from single story building.

nr

Removing and stacking trusses steel or timber 7.6m (25 L.ft)


of span from single story building.

nr

Removing and stacking trusses steel or timber 9.1m (30 L.ft)


of span from single story building.

nr

Demolishing walls bricks 112.5mm thick inclusive of plaster


and any fixtures including debris cleared away.

m2

Demolishing walls bricks above 225mm thick inclusive of


plaster and any fixtures including debris cleared away.

m3

Demolishing rubble masonry in cement and sand inclusive of


plaster and any fixtures, rubble stacked and removing debris .
m3

D-021

D-022

D-023

D-024

Demolishing reinforced concrete walls, beams or slabs up to


first floor and debris cleared away.

m3

Demolishing reinforced concrete walls, beams or slabs up to


second floor and debris cleared away.

m3

Demolishing reinforced concrete walls, beams or slabs up to


third floor and debris cleared away.

m3

Door or window size up to 4.0m2 removed from existing


walls and stacked.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

12

ITEM NO

DESCRIPTION

UNIT

D-025

Door or window size over 4.0m2 removed from existing walls


and stacked.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

13

ITEM NO

DESCRIPTION

D-026

Door or window sash size up to 4.0m2 removed from


existing frames and stacked.

D-027

UNIT

m2

Door or window sash only size over 4.0m2 removed from


existing frame and stacked.

m2

Gutters, down pipes, valleys GI or PVC including specials


removed and stacked.

D-029

Boards, valance and barge removed and stacked.

D-030

Low-level suits, squatting closets removed and stacked.

nr

D-031

Wash basins, cisterns, sinks, urinals removed and stacked.

nr

D-032

Ridges, asbestos or tile, removed and stacked.

D-033

Pipes PVC, GI, removed and stacked.

D-034

Rendering, cement, chipped and debris cleared away from


brick walls and floors.

m2

Rendering, cement, chipped and debris cleared away from


cement concrete floors and walls.

m2

Fence uprooted, barbed wire 5 strands rolled up and all


materials stacked (Length of the fence to be measured).

Tiled, glazed floor or wall demolished and debris cleared.

m2

D-028

D-035

D-036

D-037

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

14

ITEM NO

DESCRIPTION

UNIT

SECTION IV - EXCAVATOR
E-001

E-002

E-003

E-004

E-005

E-006

E-007

E-008

E-009

E-010

E-011

Earth excavation in levelling site inclusive of haulage up to


30m. (manual cutting only up to 450m3)
Earth excavation in levelling site inclusive of haulage up to
30m. (machine cutting only) in ordinary soil.
Excavation in foundations in normal earth up to depth of
1.5m inclusive of backfilling, compacting and disposal of
surplus earth.
Excavation in foundations in soft rock requiring manual
digging, up to a depth of 1.5m inclusive of backfilling and
disposal of surplus materials.

m3

m3

m3

m3

Excavation in levelling site in hard rock involving blasting


inclusive of haulage up to 30 m, and piling rubble. Extra over
earth excavation payable on rubble measurement only.

m3

Excavation in levelling site in soft rock involving manual


digging inclusive of haulage up to 30 m.

m3

Excavation in wells / pits in normal earth up to depth of 1.5m


inclusive of backfilling behind wall / ring and disposal of
surplus earth, rate excluding for shoring.
Excavation in wells / pits in normal earth 1.5m to 3.0m depth
inclusive of backfilling behind wall /ring and disposal of
surplus earth, rate excluding for shoring.
Excavation in wells / pits in normal earth 3.0m to 4.5m depth
inclusive of backfilling behind wall /ring and disposal of
surplus earth, rate excluding for shoring.
Excavation in wells / pits in normal earth 4.5m to 6.0m depth
inclusive of backfilling behind wall /ring and disposal of
surplus earth, rate excluding for shoring.
Filling earth and compacting (as approved by Engineer)
150mm layers in large quantities. Rate includes for transport
of 30 m.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m3

m3

m3

m3

m3

15

ITEM NO

DESCRIPTION

E-012

Filling earth and compacting (as approved by Engineer)


150mm layers under floors. Rate includes for transport of
30 m.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m3

16

ITEM NO

DESCRIPTION

UNIT

E-013

Shoring for excavations up to 3m height.

m2

E-014

Wells bailed out and cleaned total depth up to 3.0m


(measured, capacity of well below water table).

m3

Wells bailed out and cleaned total depth up to 4.8m


(measured, capacity of well below water table).

m3

Wells bailed out and cleaned total depth up to 7.5m


(measured, capacity of well below water table).

m3

E-015

E-016

E-017

E-018

E-019

E-020

E-021

E-022

E-023

Extra over excavation for removing boulders size exceeding


0.05m3,in any manner (Volume of each boulder measured as
0.75 x Average height x Squared area).

m3

Haulage of earth more than 30m away from site deposited


and spread by any means.

m3

Levelling ground to required grading cutting lumps and


spreading and compacting manually.

m2

Disposal of surplus earth, inclusive of loading and unloading


and transport up to 10 km.(Using Mechine)

m3

Compacting approved gravel, filled in 150mm layers by


manual tamping as specified. (Gravel available at site)

m3

River sand supplied and spread in layers as specified under


foundations, drainage sand blankets, filters, around soakage
pits, wells etc.

m3

Compacting approved gravel in 150mm layers by any means


except manual tamping as specified. (Gravel available at site)
m3

E-024

Rock excavation in column footings or wall foundations.

m3

E-025

Sand filling under foundations. (As a cushion)

m3

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

17

ITEM NO

DESCRIPTION

UNIT

SECTION V - PAVIOR
F-001

F-002

F-003

F-004

F-005

F-006

Floor - Brick 62mm thick, 1:3 cement and sand rendered


finished smooth with gray cement floating with expansion
joints filled in 1:2 bitumen and sand. (Rate including for
brick paved with 2:5 lime mortar and curing)
Floor - Brick 62mm thick, 1:3 cement and sand rendered
finished smooth with gray cement floating with expansion
joints filled in 1:2 bitumen and sand. (Rate including for
brick paved with 2:5 lime mortar and curing). Bricks
available at site.
Floor concrete 1:2 1/2:5(25mm) 75mm thick, 1:3 normal
cement and sand rendering finished smooth with expansion
joints filled with 1:2 bitumen and sand. Rate including for
curing, compacting ground and laying polythene sheets under
the concrete.
Floor concrete 1:2 1/2:5(25mm) 62mm thick, 1:3 normal
cement and sand rendering finished smooth with expansion
joints filled with 1:2 bitumen and sand. Rate including for
curing, compacting ground and laying polythene sheets under
the concrete.

Floor concrete 1:2 1/2:5(25mm) 75mm thick with expansion


joints filled with 1:2 bitumen and sand rate including for
curing, compacting ground and laying polythene sheet under
the concrete.
Floor concrete 1:2 1/2:5(25mm) 62mm thick with expansion
joints filled with 1:2 bitumen and sand rate including for
curing, compacting ground and laying polythene sheet under
the concrete.

m2

m2

m2

m2

m2

m2

F-007

Extra over supplying & fixing tile beading (Small)

F-008

Extra over Supplying & fixing tile beading (Large)

F-009

A) Floor paved with approved pattern and colour


(homogeneous /porcelain /ceramic) floor tiles on 1:3 cement
mortar, joints filled with tile grout, to match the colour of
tiles and cleaning. (Tile rate not included)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

18

ITEM NO

DESCRIPTION

UNIT

B) Add only the cost of tile + overhead and profit per m2 (Tile)
for the above rate.
* Total floor tiling rate A + B

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

19

ITEM NO

F-010

DESCRIPTION

A) 100mm high tile skirting approved pattern and colour


(homogeneous/porcelain /ceramic) floor tiles on 1:3 cement
mortar, joints filled with tile grout to match the colour of
tiles and cleaning. (Tile rate not included)

UNIT

B) Add only the cost of tile + overhead and profit per "m"
(Tile skirting) for the above rate.
* Total tile skirting rate A + B
F-011

F-012

Floor re-rendered with 1:3 cement and sand after demolition


and clearance of damaged areas, providing expansion joints
filled in 1:2 bitumen and sand (Rate including for curing).
Floor rendered with 1:3 cement and sand, normal cement
floated surface with expansion joints filled with 1:2 bitumen
sand.( Rate including for curing)

F-013

Extra over, for coloured cement floor waxed and polishing.

F-014

100mm high skirting in cement and sand 1:3 projected or


flush to walls finished smooth with gray cement floating
including forming groove.

F-015

F-016

F-017

Waterproofing in upper floor bathrooms, water tanks etc.


with cementitious waterproofing agent approved by the
Engineer, (Barralastic or equivalent) apply two coats after
well cleared surface.
Floor rendered with 1:3 cement and sand approved coloured
surface with expansion joints filled with 1:2 bitumen and
sand. (Rate including for curing)
100mm high skirting in cement and sand 1:3 finished smooth
with coloured cement including forming groove.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2
m2

m2

m2

20

ITEM NO

DESCRIPTION

UNIT

SECTION VI - MISCELLANEOUS / GENERAL


G-001

Clearing jungle along the fence.

G-002

Cutting coconut trees removing root balls and stacking logs.

nr

G-003

Cutting coconut trees and removing stumps.

nr

G-004

Cutting trees girth 0.45m to 0.9m, removing root balls and


stacking logs.

nr

G-005

Cutting trees girth 0.45m to 0.9m and stacking logs.

nr

G-006

Cutting trees girth 0.925m to 1.35m, removing root balls and


stacking logs.

nr

G-007

Cutting trees girth 0.925m to 1.35m and stacking logs.

nr

G-008

Cutting trees girth 1.375m to 1.8m, removing root balls and


stacking logs.

nr

G-009

Cutting trees girth 1.375m to 1.8m and stacking logs.

nr

G-010

Cutting trees girth 1.825m to 2.25m, removing root balls and


stacking logs.

nr

G-011

Cutting trees girth 1.8m to 2.25m and stacking logs.

nr

G-012

Cutting trees girth 2.2m to 2.7m, removing root balls and


stacking logs.

nr

G-013

Cutting trees girth 2.2m to 2.7m and stacking logs.

nr

G-014

Fence barbed wire 5 strands 14 BWG with 4 points at 75mm


crs and R.C.C posts 1:1 1/2:3 (20mm) concrete 1.70m high
and section 150mm x 150mm at bottom and 100mm x
100mm top, at 2.4m c/c , r/f with 4 nos 6mm dia. MS rods
with 14BWG wire stirrups at 150mm crs. Rate to inclusive of
excavation,1:3:6(40mm) cement concrete foundations to all
post and providing straightening bolts with washers and nuts.
m

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

21

ITEM NO

DESCRIPTION

G-015

Fence barbed wire 8 strands 14 BWG with 4 points at 75mm


crs and R.C.C posts 1:1 1/2:3 (20mm) concrete 2.25m high
and section 150mm x 150mm at bottom and 100mm x
100mm top, at 2.4m c/c, r/f with 4 nos 6mm dia. MS rods
with 14BWG wire stirrups at 150mm crs. Rate to inclusive of
excavation,1:3:6(40mm) cement concrete foundations to all
post and providing straightening bolts with washers and nuts.

UNIT

m
G-016

G-017

G-018

G-019

G-020

G-021

Fence posts intermediate, or struts, in cement concrete 1:1


1/2:3(20mm) r/f with 4 nos 6mm MS rods and 14BWG wire
stirrups at 150crs, 1.7m high and section 150mm x 150mm at
bottom and 100mm x 100mm top, as per detail drawing
including fixing with 1:3:6 concrete, excavation etc.
Fence posts intermediate, or struts, in cement concrete 1:1
1/2:3(20mm) r/f with 4 nos 6mm MS rods and 14BWG wire
stirrups at 150crs, 2.25m high and section 150mm x 150mm
at bottom and 100mm x 100mm top, as per detail drawing
including fixed with 1:3:6 concrete, excavation etc.

nr

nr

Fence posts RCC, available, refixed. Rate includes for


concreting 1:3:6(40mm) where necessary.

nr

Fence, barbed wire 14 gauge 4 points, available, strengthened


& fixed on exiting concrete or timber posts.

Fence barbed wire 14 gauge 4 Points, supplied & fixed on


existing concrete or timber posts.

Flight of steps in 1:2 1/2 :5(25mm) concrete overall width


1.5m, waist 100mm on well compacted ground, waist below
ground level, curb walls 150mm thick overall height 450mm
in outer surface. Rate includes all formwork and 1:3 cement
rendering finished smooth to exposed surfaces. size of steps
150 mm rise and 275mm tread.(Measured sloping length.)
m

G-022

Landing flight of steps 1.5m wide overall base 100mm thick,


curb walls 150mm thick and 150mm height externally, in 1:2
1/2:5(25mm) concrete, and 1:3.cement rendering finished
smooth.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

22

ITEM NO

G-023

DESCRIPTION

UNIT

Chain link mesh fence 2.0m high (Gauge 12) with 2" dia.
medium quality GI pipe at 2.4m c/c up rights and one after
the other 3/4" dia. medium quality GI pipe up right at 2.4m
c/c and 1" dia. GI pipe medium quality at top and bottom
runners, including excavation, foundation concrete work
1:2:4(20mm), welding work, painting of two coats of
anticorrosive and finished coat of enamel etc.(Chain link
fence open area 2" x 2")
m

G-024

G-025

G-026

G-027

G-028

Supplying and laying 1.5m x 1.0m x 1.0m galvanized gabion


boxes with necessary rubble packing.

nr

Supplying and laying 2.0m x 1.0m x 1.0m galvanized gabion


boxes with necessary rubble packing.

nr

Supplying and laying 1.0m x 1.0m x 1.0m galvanized gabion


boxes with necessary rubble packing.

nr

Supplying and laying geo textile layer behind gabion


retaining walls type T.S. 30.

m2

Cutting turf sods, loading to hand carts and transporting up to


30 m, laying and watering for 30days. (Royalty for turf sods,
and transport beyond 30m paid separately)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

23

ITEM NO

DESCRIPTION

UNIT

SECTION VII - DRAINAGE SYSTEMS


H-001

Elbow pvc 110mm supplied and fixed.

nr

Cleaning eye bend pvc 110mm supplied and fixed.

nr

H-002

Bend PVC 110 supplied and fixed, drainage.

nr

H-003

Type 400 pvc 110mm for sewer line supplied and laid in
medium soil, joints embedded in 1:3:6(40mm) concrete
including necessary excavation, back filling, and compaction,
invert depth up to 600mm.

H-001A

H-004

H-005

H-006

H-007

H-008

H-009

Type 400 pvc 110mm for sewer line supplied and laid in
medium soil, joints embedded in 1:3:6 (40mm) concrete
including necessary excavation, back filling, and compaction
invert depth to 600mm to 900mm.
Type 400 pvc 160mm for sewer line supplied and laid in
medium soil, joints embedded in 1:3:6(40mm) concrete
including necessary excavation, back filling, and compaction
invert depth up to 600mm.
Type 400 pvc 160mm for sewer line supplied and laid in
medium soil, joints embedded in 1:3:6(40mm) concrete
including necessary excavation, back filling, and compaction
invert depth to 600mm to 900mm.
Gully PVC 150mm supplied and fixed including concreting
and supplying necessary grating.
Manhole 600mm x 600mm x 600mm internally complete
with cement concrete 1:2:4(25mm) in 75mm thick base,
225mm tk.brick walls on top of base slab and channelling
and bending, 1:3 cement and sand rendered in internal
surfaces, 75mm thick RC. cover slab r/f 10mm tor steel @
150mm c/c. both ways, complete with lifting handles.

Manhole 600mm x 600mm internally complete with brick


walls 1:3 cement and sand rendered in internal surfaces,
extra over for each additional 0.3m depth.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

nr

nr

24

ITEM NO

DESCRIPTION

H-010

Manhole 1.05m x 0.675m x 0.60m internally complete with


cement concrete 1:2:4(25mm) in 75mm thick base, 225mm
tk.brick walls on top of base slab and channelling and
bending, 1:3 cement and sand rendered in internal surfaces,
75mm thick RC. cover slab r/f 10mm tor steel @ 150mm c/c.
both ways, complete with lifting handles.

UNIT

nr
H-011

H-012

H-013

Manhole 1.05m x 0.675m internally brick walls 225mm , 1:3


cement rendered in internal surfaces extra over each
additional 0.3 m depth.
Shallow drains in floors 75mm diameter in cement concrete
1:2:4(25mm), 75mm thick in bottom and sides including
cement and sand rendering.

nr

Construction of 1.2m diameter internal fully built type


soakage pit, built up 225mm thick brick work in 1:8
cement ,sand mortar invert depth from ground level 3.0m,on
225mm x 150mm ring beam 1:2:4(20mm) concrete mix,
including 1:3 cement,sand plaster finished smooth with neat
gray cement (0.9m invert depth only) & 100mm high
1:2:4(20mm ) concrete ring pad above ground level,
complete with 75mm thick RCC cover slab with lifting
handle.All as per detail drawing.(CP/K/119/91A).
nr

H-014

Construction of 1.2m diameter internal semi built type


soakage pit, built up 225mm thick brick work in 1:8
cement ,sand mortar invert depth from ground level 0.90m,on
225mm x 150mm ring beam 1:2:4(20mm) concrete mix,
including 1:3 cement,sand plaster finished smooth with neat
gray cement & 100mm high 1:2:4(20mm ) concrete ring pad
above ground level, complete with 75mm thick RCC cover
slab with lifting handle.All as per detail drawing.
(CP/K/119/91A).
nr

H-015

Construction of 1.8m diameter internal fully built type


soakage pit , built up 225mm thick brick work in 1:8
cement ,sand mortar invert depth from ground level 3.0m,on
225mm x 150mm ring beam 1:2:4(20mm) concrete mix,
including 1:3 cement,sand plaster finished smooth with neat
gray cement (0.9m invert depth only) & 100mm high
1:2:4(20mm ) concrete ring pad above ground level,
complete with 75mm thick RCC cover slab with lifting
handle.All as per detail drawing.(CP/K/253/92A).
nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

25

ITEM NO

DESCRIPTION

UNIT

H-016

Tee, pvc 110mm supplied and fixed drainage.

nr

H-017

Vent pvc 110mm diameter (type 400) fixed on walls with


timber plugs and pvc brackets. (Specials paid separately)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

26

ITEM NO

DESCRIPTION

UNIT

H-018

Construction of septic tank for 15 persons 2.1m x 0.75m


internally as per detail drawing No. CP/K/117/91A.

nr

Construction of septic tank for 25 persons 2.4m x 0.75m


internally as per detail drawing No. CP/K/117/91A.

nr

H-019

H-020

H-021

H-022

H-023

H-024

Construction of septic tank for 25 persons as per type plan


complete, extra over for invert depth exceeding 600mm to
1800mm, per each additional 0.3 m.
Construction of septic tank for 50 persons invert depth up to
0.75m complete as per type plan No: CP/K/121/91A.
Construction of septic tank for 50 persons as per type plan
complete, extra over for invert depth exceeding 600mm to
1800mm, per each additional 0.3 m.

nr

nr

nr

Construction of septic tank for 100 persons invert depth up to


2250mm complete as per type plan No:CP/K/121/91A.

nr

Construction of septic tank for 100 persons as per type plan


complete, extra over for invert depth exceeding 600mm to
1800mm, per each additional 0.3 m.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

27

ITEM NO

DESCRIPTION

UNIT

SECTION VIII - ELECTRICAL INSTALLATION


Note -

* Should be followed the IEE wiring regulations for electrical Installations.


* All MCCB, RCD, MCB and Isolators should be Moeller/ Orange Industrial or
Equivalent approved quality and should have more than 5 Year warranty period.
* All types of fans should be KDK Or Equivalent approved quality and should have
minimum one year warranty period.
* The Ceiling fans should have Cut-off Safety Switch and Safety Wire Provided to
Prevent Detachment of Fan Motor from the Rod.

I-001

I-002

Bell point wiring - to be carried out with 2 x 1.0 mm2 PVC


insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.(Including sunk switch)

nr

Pendent type lamp point wiring - to be carried out with 2 x


1.0 mm2 PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order.(Including sunk switch)
nr

I-003

I-004

I-005

2 Nos. of Pendent type lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling, to be supplied
and installed in to working order(including sunk switch).
3 Nos. of Pendent type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling, to be supplied
and installed in to working order(including sunk switch).

nr

nr

4 Nos. of Pendent type lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling, to be supplied
and installed in to working order(including sunk switch).
nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

28

ITEM NO
I-006

DESCRIPTION
5 Nos. of Pendent type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling, to be supplied
and installed in to working order(including sunk switch).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

29

ITEM NO

DESCRIPTION

I-007

Recessed type / Surface mounted type / Ceiling mounted type


lamp point wiring - to be carried out with 2 x 1.0 mm2 PVC
insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.(Including sunk switch)

UNIT

nr
I-008

2 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point to be controlled by one switch and
wiring to be carried out with 2 x 1.0 mm2 PVC insulated
PVC sheathed copper cables wired in concealed conduit in
wall and above ceiling to be supplied and installed in to
working order.(Including sunk switch)
nr

I-009

3 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point to be controlled by one switch and
wiring to be carried out with 2 x 1.0 mm2 PVC insulated
PVC sheathed copper cables wired in concealed conduit in
wall and above ceiling to be supplied and installed in to
working order.(Including sunk switch)
nr

I-010

I-011

Bell point wiring - to be carried out with 2 x 1.0 mm2 PVC


insulated PVC sheathed copper cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.(Including sunk switch)

nr

5 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point to be controlled by one switch and
wiring to be carried out with 2 x 1.0 mm2 PVC insulated
PVC sheathed copper cables wired in concealed conduit in
wall and above ceiling to be supplied and installed in to
working order.(Including sunk switch)
nr

I-012

1 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including Sunk switch).
nr

I-013

2 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including Sunk switch).
nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

30

ITEM NO
I-014

DESCRIPTION

UNIT

3 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including Sunk switch).
nr

I-015

4 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including Sunk switch).
nr

I-016

I-017

5 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including Sunk switch).

nr

Indoor bracket lamp point wiring to be carried out with 2 x


1.0 mm2 PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order. ( Including sunk switch).
nr

I-018

2 Nos. of Indoor bracket lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order. ( Including sunk switch).
nr

I-019

3 Nos. of Indoor bracket lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order. ( Including sunk switch).
nr

I-020

Stairway lamp point wiring - to be carried out with 2 x


1.0mm2 PVC insulated PVC sheathed copper cables wired in
concealed conduit in wall and above ceiling to be supplied
and installed in to working order (Including one gang two
way switch).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

31

ITEM NO

DESCRIPTION

I-021

Ceiling fan point wiring complete with fan hook - to be


carried out with 2 x 1.0 mm2 PVC insulated PVC sheathed
copper cables and 2.5mm2 earth cable wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.

UNIT

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

32

ITEM NO
I-022

DESCRIPTION

UNIT

5 A socket outlet - wiring to be carried out with 2 x 1.0mm2


PVC insulated PVC sheathed copper cables and 2.5mm2
earth cable wired in concealed conduit in wall and above
ceiling to be supplied and installed in to working order.
nr

I-023

2 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired in concealed conduit in wall and
above ceiling to be supplied and installed in to working order.
nr

I-024

3 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired in concealed conduit in wall and
above ceiling to be supplied and installed in to working order.
nr

I-025

4 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired in concealed conduit in wall and
above ceiling to be supplied and installed in to working order.
nr

I-026

13 A socket outlet / Grouped socket outlets - wiring to be


carried out with 2 x 2.5mm2 PVC insulated PVC sheathed
copper cables and 2.5mm2 earth cable wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order. For additional circuit length over 10m,
Item no I-223 should be added per meter.
nr

I-027

15 A socket outlet - wiring to be carried out with 2 x 2.5mm2


PVC insulated PVC sheathed copper cables and 2.5mm2
earth cable wired in concealed conduit in wall and above
ceiling to be supplied and installed in to working order. For
additional circuit length over 10m, Item no I-223 should be
added per meter.
nr

I-028

Data socket outlet ( RJ 45 ) wiring be carried out with 5U/


UTP AWG 24 CAT 5E PVC cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

33

ITEM NO

DESCRIPTION

I-029

Data socket outlet ( RJ 45 ) wiring be carried out with 6U/


UTP AWG 24 CAT 6E PVC cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

34

ITEM NO

DESCRIPTION

I-030

Telephone socket outlet ( RJ 11 ) wiring be carried out with


2X 0.5 mm2 Single Pair - BS 3573 cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.

I-031

I-032

I-033

Telephone socket outlet ( RJ 11 ) wiring be carried out with


2X 0.5 mm2 Two Pair - BS 3573 cables wired in concealed
conduit in wall and above ceiling to be supplied and installed
in to working order.
Bell point wiring - to be carried out with 2 x 1.0 mm2 PVC
insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order. (Including sunk switch)

UNIT

nr

nr

nr

Pendent type lamp point wiring - to be carried out with 2 x


1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-034

I-035

2 Nos. of Pendent type lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

nr

3 Nos. of Pendent type lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
nr

I-036

I-037

4 Nos. of Pendent type lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
5 Nos. of Pendent type lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

nr

35

ITEM NO

DESCRIPTION

I-038

Recessed type / Surface mounted type / Ceiling mounted type


lamp point wiring - to be carried out with 2 x 1.0 mm2 PVC
insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

36

ITEM NO

I-039

DESCRIPTION

UNIT

2 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-040

3 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-041

4 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-042

5 Nos of Recessed type / Surface mounted type / Ceiling


mounted type lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-043

I-044

Watertight lamp point wiring - to be carried out with 2 x 1.0


mm2 PVC insulated PVC sheathed copper cables wired with
PVC casing on wall and on soffit of the slabs to be supplied
and installed in to working order (Including sunk switch).

nr

2 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
nr

I-045

3 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

37

ITEM NO

DESCRIPTION

I-046

4 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

I-047

I-048

I-049

I-050

I-051

5 Nos. of Watertight lamp points to be controlled by one


switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
Indoor bracket lamp point wiring - to be carried out with 2 x
1.0 mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
2 Nos. of Indoor bracket lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
3 Nos. of Indoor bracket lamp points to be controlled by one
switch - point wirings to be carried out with 2 x 1.0 mm2
PVC insulated PVC sheathed copper cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).

UNIT

nr

nr

nr

nr

nr

Stairway lamp point wiring - to be carried out with 2 x


1.0mm2 PVC insulated PVC sheathed copper cables wired
with PVC casing on wall and on soffit of the slabs to be
supplied and installed in to working order (Including sunk
switch).
nr

I-052

Ceiling fan point wiring complete with fan hook - to be


carried out with 2 x 1.0 mm2 PVC insulated PVC sheathed
copper cables and 2.5mm2 earth cable wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order (Including sunk switch).
nr

I-053

5 A socket outlet - wiring to be carried out with 2 x 1.0mm2


PVC insulated PVC sheathed copper cables and 2.5mm2
earth cable wired with PVC casing on wall and on soffit of
the slabs to be supplied and installed in to working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

38

ITEM NO

DESCRIPTION

I-054

2 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired with PVC casing on wall and on
soffit of the slabs to be supplied and installed in to working
order.

UNIT

nr
I-055

3 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired with PVC casing on wall and on
soffit of the slabs to be supplied and installed in to working
order.
nr

I-056

I-057

4 Nos of 5 A socket outlets - wiring to be carried out with 2 x


2.5mm2 PVC insulated PVC sheathed copper cables and
2.5mm2 earth cable wired with PVC casing on wall and on
soffit of the slabs to be supplied and installed in to working
order.

nr

13 A socket outlet / Grouped socket outlets -wiring to be


carried out with 2 x 2.5mm2 PVC insulated PVC sheathed
copper cables and 2.5mm2 earth cable wired with PVC casing
on wall and on soffit of the slabs to be supplied and installed
in to working order. For additional circuit length over 10m,
Item no I-224 should be added per meter.
nr

I-058

15 A socket outlet -wiring to be carried out with 2 x 2.5mm2


PVC insulated PVC sheathed copper cables and 2.5mm2
earth cable wired with PVC casing on wall and on soffit of
the slabs to be supplied and installed in to working order.
For additional circuit length over 10m, Item no I-224 should
be added per meter.
nr

I-059

Data socket outlet ( RJ 45 ) wiring be carried out with 5U/


UTP AWG 24 CAT 5E PVC cables wired with PVC casing
on wall and on soffit of the slabs to be supplied and installed
in to working order.
nr

I-060

Data socket outlet ( RJ 45 ) wiring be carried out with 6U/


UTP AWG 24 CAT 6E PVC cables wired with PVC conduits
wired with PVC casing on wall and on soffit of the slabs to
be supplied and installed in to working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

39

ITEM NO
I-061

DESCRIPTION
Telephone socket outlet ( RJ 11 ) wiring be carried out with
2X 0.5 mm2 Single Pair - BS 3573 cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

40

ITEM NO
I-062

I-063
I-064
I-065

I-066

I-067

I-068

I-069

I-070

I-071

I-072

I-073

I-074

I-075

I-076

DESCRIPTION
Telephone socket outlet ( RJ 11 ) wiring be carried out with
2X 0.5 mm2 Two Pair - BS 3573 cables wired with PVC
casing on wall and on soffit of the slabs to be supplied and
installed in to working order.

UNIT

nr

Supplying and installing of 2 x 1 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 2 x 1.5 mm2 Cu/ PVC/ PVC


cable Concealed in conduits.

Supplying and installing of 2 x 2.5 mm2 Cu/ PVC/ PVC


cable Concealed in conduits.

Supplying and installing of 2 x 4 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 2 x 6 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 2 x 10 mm2 Cu/ PVC/ PVC cable


concealed in conduits.

Supplying and installing of 2 x 16 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 2 x 25 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 2 x 1 mm2 Cu/ PVC/ PVC + 2.5


mm2 E cable Concealed in conduits.
Supplying and installing of 2 x 1.5 mm2 Cu/ PVC/ PVC +
2.5 mm2 E cable Concealed in conduits.
Supplying and installing of 2 x 2.5 mm2 Cu/ PVC/ PVC +
2.5 mm2 E cable Concealed in conduits.
Supplying and installing of 2 x 4 mm2 Cu/ PVC/ PVC + 2.5
mm2 E cable Concealed in conduits.
Supplying and installing of 2 x 6 mm2 Cu/ PVC/ PVC + 6
mm2 E cable Concealed in conduits.
Supplying and installing of 2 x 10 mm2 Cu/ PVC/ PVC + 10
mm2 cable concealed in conduits.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

41

ITEM NO
I-077

I-078
I-079

I-080

I-081

I-082

I-083

I-084

I-085

I-086

I-087

I-088

I-089

I-090

I-091

DESCRIPTION
Supplying and installing of 2 x 16 mm2 Cu/ PVC/ PVC +
16mm2 E cable Concealed in conduits.

UNIT

Supplying and installing of 2 x 25 mm2 Cu/ PVC/ PVC +


16mm2 E cable Concealed in conduits.

Supplying and installing of 4 x 4 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 4 x 6 mm2 Cu/ PVC/ PVC cable


Concealed in conduits.

Supplying and installing of 4 x 10 mm2 Cu/ PVC/ PVC


cable concealed in conduits.

Supplying and installing of 4 x 16 mm2 Cu/ PVC/ PVC


cable Concealed in conduits.

Supplying and installing of 4 x 25 mm2 Cu/ PVC/ PVC


cable Concealed in conduits.

Supplying and installing of 4 x 35 mm2 PVC/XLPE/CU


cable Concealed in conduits.

Supplying and installing of 4 x 4 mm2 Cu/ PVC/ PVC + 4


mm2 E cable Concealed in conduits.
Supplying and installing of 4 x 6 mm2 Cu/ PVC/ PVC + 6
mm2 E cable Concealed in conduits.
Supplying and installing of 4 x 10 mm2 Cu/ PVC/ PVC + 10
mm2 E cable concealed in conduits.
Supplying and installing of 4 x 16 mm2 Cu/ PVC/ PVC +
16mm2 E cable Concealed in conduits.
Supplying and installing of 4 x 25 mm2 Cu/ PVC/ PVC +
16mm2 E cable Concealed in conduits.
Supplying and installing of 4 x 35 mm2 PVC/XLPE/CU + 16
mm2 E cable Concealed in conduits.
Supplying and installing of 2.5 mm2 earth cable concealed in
conduit.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

42

ITEM NO
I-092

I-093

I-094

I-095

I-096

I-097

I-098

I-099

I-100

I-101

I-102

I-103

I-104

I-105

I-106

I-107

DESCRIPTION
Supplying and installing of 4 mm2 earth cable concealed in
conduit.
Supplying and installing of 6 mm2 earth cable concealed in
conduit.
Supplying and installing of 10 mm2 earth cable concealed in
conduit.
Supplying and installing of 16 mm2 earth cable concealed in
conduit.
Supplying and installing of 25 mm2 earth cable concealed in
conduit.
Supplying and installing of 35 mm2 earth cable concealed in
conduit.
Supplying and installing of 2 x 1 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 1.5 mm2 Cu/ PVC/ PVC
cable with casing.
Supplying and installing of 2 x 2.5 mm2 Cu/ PVC/ PVC
cable with casing.
Supplying and installing of 2 x 4 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 6 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 10 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 16 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 25 mm2 Cu/ PVC/ PVC cable
with casing.
Supplying and installing of 2 x 1 mm2 Cu/ PVC/ PVC + 2.5
mm2 E cable with casing.
Supplying and installing of 2 x 1.5 mm2 Cu/ PVC/ PVC +
2.5 mm2 E cable with casing.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m
43

ITEM NO
I-108

I-109

I-110

I-111

I-112
I-113

I-114

I-115

I-116

I-117

I-118

I-119

I-120

I-121

I-122

DESCRIPTION
Supplying and installing of 2 x 2.5 mm2 Cu/ PVC/ PVC +
2.5 mm2 E cable with casing.
Supplying and installing of 2 x 4 mm2 Cu/ PVC/ PVC + 2.5
mm2 E cable Concealed in casing.
Supplying and installing of 2 x 6 mm2 Cu/ PVC/ PVC + 6
mm2 E cable Concealed in casing.
Supplying and installing of 2 x 10 mm2 Cu/ PVC/ PVC + 10
mm2 cable with casing.
Supplying and installing of 2 x 16 mm2 Cu/ PVC/ PVC +
16mm2 E cable with casing.
Supplying and installing of 2 x 25 mm2 Cu/ PVC/ PVC +
16mm2 E cable with casing.

UNIT

m
m

Supplying and installing of 4 x 4 mm2 Cu/ PVC/ PVC cable


with casing.

Supplying and installing of 4 x 6 mm2 Cu/ PVC/ PVC cable


with casing.

Supplying and installing of 4 x 10 mm2 Cu/ PVC/ PVC


cable with casing.

Supplying and installing of 4 x 16 mm2 Cu/ PVC/ PVC


cable with casing.

Supplying and installing of 4 x 25 mm2 Cu/ PVC/ PVC


cable with casing.

Supplying and installing of 4 x 4 mm2 Cu/ PVC/ PVC + 4


mm2 E cable with casing.
Supplying and installing of 4 x 4 mm2 Cu/ PVC/ PVC + 4
mm2 E cable with casing.
Supplying and installing of 4 x 6 mm2 Cu/ PVC/ PVC + 6
mm2 E cable with casing.
Supplying and installing of 4 x 10 mm2 Cu/ PVC/ PVC + 10
mm2 cable with casing.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

44

ITEM NO
I-123

I-124

I-125

DESCRIPTION
Supplying and installing of 4 x 16 mm2 Cu/ PVC/ PVC +
16mm2 E cable with casing.
Supplying and installing of 4 x 25 mm2 Cu/ PVC/ PVC +
16mm2 E cable with casing.
Supplying and installing of 4 x 35 mm2 PVC/XLPE/CU + 16
mm2 E cable with Casing.

UNIT

I-126

Supplying and installing of 2.5 mm2 earth cable with casing.

I-127

Supplying and installing of 4 mm2 earth cable with casing.

I-128

Supplying and installing of 6 mm2 earth cable with casing.

I-129

Supplying and installing of 10 mm2 earth cable with casing.

I-130

Supplying and installing of 16 mm2 earth cable with casing.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

45

ITEM NO

DESCRIPTION

UNIT

I-131

Supplying and installing of 25 mm2 earth cable with casing.

I-132

Supplying and installing of 35 mm2 earth cable with casing.

I-133

Supplying and installing of 4X35mm2 CU/XLPE/SWA/PVC


- Armourd cable (Excluding Floor excavation, Civil works
or Cable ladder installation)

I-134

I-135

I-136

I-137

I-138

I-139

I-140

I-141

I-142

Supplying and installing of 4X25mm2 CU/XLPE/SWA/PVC


- Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 2X25mm2 CU/XLPE/SWA/PVC
- Armoured cable (Excluding Floor excavation, Civil works
or Cable ladder installation)
Supplying and installing of 2X35mm2 CU/XLPE/SWA/PVC
- Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 2X4 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 2X6 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 2X10 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 2X16 mm2 CU/PVC/SWA/PVC
cable (Excluding Floor excavation, Civil works or Cable
ladder installation)
Supplying and installing of 4X2.5 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 4X4 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

46

ITEM NO
I-143

I-144

I-145

I-146

I-147
I-148

I-149

I-150

I-151

I-152

I-153

I-154

DESCRIPTION
Supplying and installing of 4X6 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 4X10 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)
Supplying and installing of 4X16 mm2 CU/PVC/SWA/PVC Armourd cable (Excluding Floor excavation, Civil works or
Cable ladder installation)

UNIT

Supplying and fixing Pendent type Lamp c/w 200mm dia.


conical Polycarbonate shade and 15W CFL bulb to working
order.

nr

Supplying and installing Pendent type Lamp c/w 200mm dia.


glass globe and 15W CFL bulb to working order.

nr

Supplying and installing Watertight wall bracket lamp c/w


200mm dia. clear acrylic globe and 15W C.F.L. bulb, to
working order.

nr

Supplying and installing indoor wall bracket lamp c/w


200mm dia. opal white glass globe and 15W CFL bulb to
working order.
Supplying and installing recessed fluorescent lamp fitting
1200mm x 300mm, complete with polished aluminium
double parabolic louver and 2 Nos 36 W,1200mm
fluorescent bulbs to working order.
Supplying and installing recessed fluorescent lamp fitting
600mm x 600mm, complete with polished aluminium double
parabolic louver and 3 Nos 18 W,600mm fluorescent bulbs
to working order.

nr

nr

nr

Supplying and installing fluorescent lamp fittings 1200mm


single batten type with 1Nos 36 W,1200mm fluorescent bulb
to working order.

nr

Supplying and installing fluorescent lamp fittings 1200mm,


complete with prismatic diffuser and 1No 36W 1200mm
fluorescent bulb to working order.

nr

Supplying and installing fluorescent lamp fittings 1200mm,


complete with prismatic diffuser and 2No 36W 1200mm
fluorescent bulb to working order.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

47

ITEM NO
I-155

I-156

I-157

DESCRIPTION

UNIT

Supplying and installing fluorescent lamp fittings 600mm,


complete with prismatic diffuser and 1No 18W 600mm
fluorescent bulb to working order.

nr

Supplying and installing Fluorescent lamp fitting 600mm


complete with Opal white diffuser and 1 No of 18w 600mm
fluorescent bulb to working order.

nr

Supplying and installing Fluorescent lamp fitting 1200mm


complete with Opal white diffuser and 1 No of 36w 1200mm
fluorescent bulb to working order.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

48

ITEM NO

DESCRIPTION

UNIT

I-158

Supplying and installing Fluorescent lamp fitting 1200mm


complete with Opal white diffuser and 2 No of 36w 1200mm
fluorescent bulb to working order.

nr

Supplying and installing recessed (Ceiling mount) down light


complete with 5" dia. polish aluminium reflector and 18W
C.F.L. bulb , to working order.

nr

Supplying and installing recessed (Ceiling mount) down light


complete with 5" dia. polish aluminium reflector and 15W
C.F.L. bulb , to working order.

nr

Supplying and installing cylindrical down light (Surface


mount) complete with 5" dia. polish aluminium reflector and
18 W C.F.L. bulb , to working order.

nr

Supplying and installing cylindrical down light (Surface


mount) complete with 5" dia. polish aluminium reflector and
15 W C.F.L. bulb , to working order.

nr

Supplying and installing Watertight bracket lamp (Small size)


with 15 W CFL bulb to working order.

nr

Supplying and installing Watertight bracket lamp (Small size)


with 18 W CFL bulb to working order.

nr

I-159

I-160

I-161

I-162

I-163

I-164

I-165

Supplying and installing 15 W CFL Globe to working order.


nr

I-166
I-167
I-168

Supplying and installing 150W Halogen Floodlight in to


working order.

nr

Supplying and installing of door bell with bell push


(excluding wiring) to working order.

nr

Supplying and installing of ceiling fan 1400mm dia. complete


with 5 speed regulator (excluding wiring) to working order.
nr

I-169

I-170

I-171

Supplying and installing of 200mm dia. exhaust fan with auto


shutter (excluding wiring) to working order.

nr

Supplying and installing of wall fan with speed regulator to


working order (excluding wiring).

nr

Supplying and installing of 5 A socket outlet to working


order.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

49

ITEM NO
I-172
I-173

DESCRIPTION

UNIT

Supplying and installing of 13 A socket outlet to working


order.

nr

Supplying and installing of 15 A socket outlet to working


order.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

50

ITEM NO
I-174

I-175
I-176
I-177

I-178

I-179

I-180

I-181

I-182

I-183

I-184

I-185

I-186

DESCRIPTION

UNIT

Supplying and installing of 5 A socket outlet with Neon


indicator to working order.

nr

Supplying and installing of 13 A socket outlet with Neon


indicator to working order.

nr

Supplying and installing of 15 A socket outlet with Neon


indicator to working order.

nr

Supplying and installing of RJ 45 Data socket outlet to


working order.
Supplying and installing of RJ 11 Telephone socket outlet to
working order.
Supplying and installing of earth electrode 20mm dia. 4 feet
long to working order complete with forming of gully around
the earth electrode.
Supplying and installing of earth electrode 2" dia. GI Pipe 5
feet long to working order complete with forming of gully
around the pipe.
Supplying and fixing 6 way Single Phase Distribution Board
including 32 A 2P Isolator , 40A DP R.C.D. (30mA) , 02 Nos
single pole M.C.B s.
Supplying and fixing 8 way Single Phase Distribution Board
including 32 A 2P Isolator , 40A DP R.C.D. (30mA) , 04 Nos
single pole M.C.B s.
Supplying and fixing 10 way Single Phase Distribution
Board including 32 A 2P Isolator , 40A DP R.C.D. (30mA) ,
06 Nos single pole M.C.B s.
Supplying and fixing 12 way Single Phase Distribution
Board including 32 A 2P Isolator , 40A DP R.C.D. (30mA) ,
08 Nos single pole M.C.B s.

nr

nr

nr

nr

nr

nr

nr

nr

Supplying and fixing 14 way Single Phase Distribution


Board including 32 A 2P Isolator , 40A DP R.C.D. (30mA) ,
10 Nos single pole M.C.B s.

nr

Supplying and fixing 16 way Single Phase Distribution


Board including 32 A 2P Isolator , 40A DP R.C.D. (30mA) ,
12 Nos single pole M.C.B s.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

51

ITEM NO

DESCRIPTION

UNIT

I-187

Supplying and fixing 6 way Single Phase Distribution Board


including 63 A 2P Isolator , 63A DP R.C.D. (30mA) , 02 Nos
single pole M.C.B s.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

52

ITEM NO

DESCRIPTION

UNIT

I-188

Supplying and fixing 8 way Single Phase Distribution Board


including 63 A 2P Isolator , 63A DP R.C.D. (30mA) , 04 Nos
single pole M.C.B s.

nr

Supplying and fixing 10 way Single Phase Distribution


Board including 63 A 2P Isolator , 63A DP R.C.D. (30mA) ,
06 Nos single pole M.C.B s.

nr

Supplying and fixing 12 way Single Phase Distribution


Board including 63 A 2P Isolator , 63A DP R.C.D. (30mA) ,
08 Nos single pole M.C.B s.

nr

Supplying and fixing 14 way Single Phase Distribution


Board including 63 A 2P Isolator , 63 DP R.C.D. (30mA) , 10
Nos single pole M.C.B s.

nr

Supplying and fixing 16 way Single Phase Distribution


Board including 63 A 2P Isolator , 63A DP R.C.D. (30mA) ,
12 Nos single pole M.C.B s.

nr

Supplying and installing of Three Phase Distribution Board


including 63 A, 4P Isolator, 63A 4P RCD, in surface
mounted plastic enclosure.

nr

Supplying and installing of Three Phase Distribution Board


including 100 A, 4P Isolator, 100A,4P RCD. in surface
mounted metal enclosure.

nr

Supplying and installing of 100 A, 4P, M.C.C.B. in a surface


mounted metal enclosure.

nr

I-189

I-190

I-191

I-192

I-193

I-194

I-195
I-196

I-197

I-198
I-199
I-200
I-201

Supplying and installing of 40 A, 2P, Isolator in plastic


enclosure.
Supplying and installing of 63 A, 2P, Isolator in plastic
enclosure.

nr

nr

Supplying and installing of 40 A, 4P, Isolator in plastic


enclosure.

nr

Supplying and installing of 63 A, 4P, Isolator in plastic


enclosure.

nr

Supplying and installing of 40A,30mA, 2P, R.C.D. in a


surface mounted plastic enclosure .

nr

Supplying and installing of 63A,30mA, 2P, R.C.D. in a


surface mounted plastic enclosure .

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

53

ITEM NO
I-202
I-203
I-204

I-205

I-206

I-207

I-208

DESCRIPTION

UNIT

Supplying and installing of 40A,30mA, 4P, R.C.D. in a


surface mounted plastic enclosure .

nr

Supplying and installing of 63A,30mA, 4P, R.C.D. in a


surface mounted plastic enclosure .

nr

Supplying and installing 28 way (14X2) 2 row metal


enclosure including 2 Nos of 40A 2P Isolator, 40A/ 30mA 2P
RCD, 20 Nos of 1P MCB and all other necessary items
including internal wiring in to working order.
Supplying and installing 28 way (14X2) 2 row metal
enclosure including 2 Nos of 63A 2P Isolator, 63A 30mA 2P
RCD, 20 Nos of 1P MCB and all other necessary items
including internal wiring in to working order.
Supplying and installing 28 way (14X2) 2 row metal
enclosure including 1 No of 40A 2P Isolator, 1 No of 40A/
30mA 2P RCD, 15 Nos of 1P MCB and all other necessary
items including internal wiring in to working order.
Supplying and installing 28 way (14X2) 2 row metal
enclosure including 1 No of 63A 2P Isolator, 1 No of 63A
30mA 2P RCD, 20 Nos of 1P MCB and all other necessary
items including internal wiring in to working order.

nr

nr

nr

nr

Supplying and installing 42 way (14X3) 3 row metal


enclosure including 3 Nos of 40A 2P Isolator, 3 Nos of 40A/
30mA 2P RCD, 30 Nos of 1P MCB and all other necessary
items including internal wiring in to working order.
nr

I-209

I-210

I-211

Supplying and installing 42 way (14X3) 3 row metal


enclosure including 3 Nos of 63A 2P Isolator, 3 Nos of 63A
30mA 2P RCD, 30 Nos of 1P MCB and all other necessary
items including internal wiring in to working order.
Supplying and installing 56 way (14X4) 4 row metal
enclosure including 3 Nos of 32A 2P MCB, 3 Nos of 40A/
30mA 2P RCD, 1 No of 40A 4P Isolator ,30 Nos of 1P MCB
and all other necessary items including internal wiring in to
working order.
Supplying and installing 56 way (14X4) 4 row metal
enclosure including 3 Nos of 63A 2P MCB, 3 Nos of 63A
30mA 2P RCD, 1 No of 63A 4P Isolator, 30 Nos of 1P MCB
and all other necessary items including internal wiring in to
working order.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

nr

nr

54

ITEM NO
I-212

DESCRIPTION
Supplying and installing 400X400X200mm metal enclosure
including 1 No of 32A 4P MCCB, 1 No of 40A/1000mA 4P RCD
& MCBs (15 single pole spaces are available for RCD & MCBs)
and all other necessary items including internal wiring in to
working order. (Refer Item Nos. I-217 to I-222)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

55

ITEM NO
I-213

I-214

I-215

I-216

DESCRIPTION
Supplying and installing 400X600X200mm metal enclosure
including 1 No of 32A 4P MCCB, 1 No of 40A/ 100mA 4P RCD
& MCBs (30 single pole spaces are available for RCD & MCBs)
and all other necessary items including internal wiring in to
working order.(Refer Item Nos. I-217 to I-222)
Supplying and installing 600X600X200mm metal enclosure
including 1 No of 63A 4P MCCB, 1 No of 63A/ 100mA 4P RCD
& MCBs (25 single pole spaces are available for RCD & MCBs)
and all other necessary items including internal wiring in to
working order. (Refer Item Nos. I-217 to I-222)
Supplying and installing 600X800X200mm metal enclosure
including 1 No of 63A 4P MCCB, 1 No of 63A/ 100mA 4P RCD
& MCBs (50 single pole spaces are availablefor RCD & MCBs)
and all other necessary items including internal wiring in to
working order. (Refer Item Nos. I-217 to I-222)
Supplying and installing 600X800X200mm metal enclosure
including 1 No of 100A 4P MCCB, 1 No of 4C/T type EFR &
MCBs (50 Single pole Spaces are available for MCBs) and all
other necessary items including internal wiring in to working
order. (Refer Item Nos. I-217 to I-222)

UNIT

nr

nr

nr

nr

I-217

Supplying 1 No of 2P MCB(6A,10A,16A,20A,25A,32A)

nr

I-218

Supplying 1 No of 2P MCB 63A

nr

I-219

Supplying 1 No of 3P MCB(6A,10A,16A,20A,25A,32A)

nr

I-220

Supplying 1 No of 3P MCB 63A

nr

I-221

Supplying 1 No of 2P MCB 40A

nr

I-222

Supplying 1 No of 3P MCB 40A

nr

I-223

Supply and installation of 2X2.5mm2 Cu/PVC/PVC + 2.5


mm2 Earth cable concealed in conduits for additional Linear
circuit length of 13A & 15A socket outlet wiring .

I-224

Supply and installation of 2X2.5mm2 Cu/PVC/PVC + 2.5


mm2 Earth cable wired with PVC casing for additional Linear
circuit length of 13A & 15A socket outlet wiring .

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

56

ITEM NO

DESCRIPTION

UNIT

SECTION IX - CARPENTER AND JOINER


Note -

All Aluminium extrusions are Rowel or equivalent.

J-001

Supplied & fixed brass barrel bolts 100mm with brass


screws.

nr

Supplied & fixed oxidized iron barrel bolts 100mm with iron
screws.

nr

Supplied & fixed brass barrel bolts 150mm


screws.

nr

J-002

J-003

J-004

J-005

J-006

with brass

Supplied & fixed oxidized iron barrel bolts 150mm


iron screws.

with
nr

Supplied & fixed butt hinges brass 100mm x 62mm with


brass screws.

Pr

Supplied & fixed butt hinges oxidized iron


62mm with iron screws.

Pr

100mm x

J-007

Supplied and fixed casement stays 250mm iron oxidized.

nr

J-008

Supplied and fixed casement stays 300mm brass ,circular


type with brass screws.

nr

J-009

J-010

Collapsible door, iron, open type complete with locking


arrangement and apply two coats of anticorrosive paint and
two coats of enamel paint.

m2

Door 28mm thick, cl.1 timber battened sash with 95mm x


45mm frame, in cl.1 timber, oxidized iron heavy duty
furniture 100mm x 62mm iron butt hinges with in side and
out side 100mm barrel bolts and draw ring & painted sashes
and frame, two coats of enamel paint with primer under
coats.(3 Nos of hingers)
m2

J-011

Door 28mm thick Jack/special class timber battened, sash


single hung with 95mm x 45mm Jack/special with frame ,
oxidized iron heavy duty furniture, 2 nos of 100mm barrel
bolts. Rate to included primer under coats and two coats of
enamel paint.(3 Nos of hingers)
m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

57

ITEM NO

DESCRIPTION

J-012

Door 28mm thick Cl.I timber flush paneled sash single hung
with 95mm x 70mm frame, in Treated kempas timber,
oxidized heavy duty furniture, Union or Yale original mortice
lock, 100mm barel bolts 02 Nos etc,rate to included primer
under coats and two coats of enamel paint.(3Nos of hingers)

UNIT

m2
J-013

Door 28mm thick Jack or special class timber flush paneled


sash single hung with 95mm x 70mm frame, in Jack timber,
oxidized heavy duty furniture, Union or Yale original mortice
lock,100mm barel bolts 02 nos etc.rate to included primer
under coats and two coats of enamel paint.(3Nos of hingers)
m2

J-014

Door 28mm thick class I timber panelled & glazed double


hung sashes and top fanlight 95mm x 70mm frame,Treated
kempas timber, oxidized heavy duty furniture, Union or Yale
original mortise lock,100mm barrel bolt and150mm barrel
bolt, casement stay rate included to primer under coat & two
coats of enamel paint.(5pairs of hingers)
m2

J-015

Door 28mm thick Jack/special class timber panelled & glazed


double hung sashes and top fanlight 95mm x 70mm frame, in
Jack/special timber, oxidized heavy duty furniture, Union or
Yale original mortise lock,2 nos of 100mm barrel bolt &
150mm barrel bolt,casement stay rate included to primer
under coat & two coats of enamel paint. (5pairs of hingers)
m2

J-016

J-017

Door 28mm thick Cl.I timber flush panelled, sash with 95mm
x 45mm frame, in cl.1 timber, oxidized heavy duty furniture
with inside and out side 100mm bolts in lieu of lock and rate
included to primer under coat & two coats of enamel paint.
(3Nos of hingers)
Door 28mm thick Jack/special flush panelled, with 95mm x
45mm frame, in Jack/special timber, oxidized heavy duty
furniture with inside and out side 100mm bolts in lieu of
lock and rate included primer under coat & two coats of
enamel paint. (3Nos of hingers)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

58

ITEM NO

DESCRIPTION

J-018

Door 28mm thick plywood sash with 95mm x 70mm Treated


kempas frame, oxidized heavy duty furniture, Union or Yale
original mortice lock, rate to included primer under coats
and two coats of enamel paint.(3Nos of hingers)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m2

59

ITEM NO

DESCRIPTION

J-019

Door 28mm thick plywood sash with 95mm x 70mm special


timber frame, oxidized heavy duty furniture, Union or Yale
original mortise lock, rate to included primer under coat &
two coats of enamel paint.(3Nos of hingers)

J-020

J-021

Door and window frames repaired and re-fixed ,timber if


used measured separately.
Door or window sash repaired and re- fixed (timber, except
beadings if used measured separately).

UNIT

m2

nr

m2

J-022

Supplied and fixed oxidized iron draw rings 40mm .

nr

J-023

Supplying & fixing glass panes 3mm thick, clear/pinhead,


rate includes for necessary beadings etc.

m2

Supplying & fixing glass panes 4.6mm clear / pinhead ,rate


includes for necessary beadings etc.

m2

Supplying & fixing oxidized iron hasp & staple 100mm to


150mm with 50mm heavy duty best quality padlock.

nr

J-026

Supplying & fixing lock rim or night latch (Chinese) .

nr

J-027

Supplying & fixing lock Union or equivalent mortise.

nr

J-028

Supplying & fixing lock Union or equivalent mortise to


double hung doors.

nr

J-024

J-025

J-029

J-030

Security weld mesh door sash with locking device, in GI


weld mesh 50mm x 50mm SWG 10, welded on
40mm x 40mm x 5mm MS angle frame complete with
application of two coats enamel paint over two coats of
anticorrosive paint complete .
Security weld mesh in open type buildings in GI weld mesh
50mm x 50mm SWG 10, welded on 40mm x 40mm x 5mm
angle frame complete with application of two coats enamel
paint over two coats of anticorrosive paint complete .

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

60

ITEM NO

DESCRIPTION

J-031

Special security grill fixed to aluminium windows complete.


(in 16mm x 5mm flat iron frame & SWG 10, 50mm x50mm
weld mesh complete with application of two coats enamel
paint over two coats of anticorrosive paint.)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m2

61

ITEM NO

DESCRIPTION

J-032

Special security grill fixed for windows complete with


perimeter & either side of middle opening frame 16mm x
5mm M.S.flat, internal horizontal members not exceeding
100mm c/c & vertical members not exceeding 150mm c/c in
12mm x 5mm.M.S flat & properly welded and fixed to walls
with rawl plugs, screws inclusive of apply on two coats of
anticorrosive paint & two coats of enamel paint.

UNIT

m2
J-033

J-034

J-035

J-036

J-037

J-038

J-039

J-040

J-041

Special security grill fixed for windows complete with


perimeter & either side of middle opening frame in 16mm x
5mm M.S flat & 6mm dia.MS bars at 100mm c/c
diagonally ,properly welded & fixed to walls with rawl plugs,
screws inclusive of two coats of enamel paint on two coats of
anticorrosive paint.

m2

Timber used in repairing door & window frames, treated


kempas, 95mm x 45mm.

Timber used in repairing door & window frames, treated


kempas, 95mm x 70mm.

Timber used in repairing door & window frames, Jack


timber 95mm x 45mm.

Timber used in repairing door & window frames, Jack timber


95mm x 70mm.

Timber used in repairing doors & windows , cl.1 timber up to


28mm thick planks.

m2

Timber used in repairing doors & windows, special class


timber up to 28mm thick planks.

m2

Window fully glazed 28mm thick Cl. I timber sashes and


nominal thickness 95mmx70mm frame in treated kempas
timber complete with oxidized heavy-duty furniture,3.0mm
clear / pinhead glass, including two coats of enamel paint &
primer under coat.
Window fully glazed 28mm thick Jack /Special sashes and
95mm x 70mm frame Jack timber complete with oxidized
heavy duty furniture,3.0mm clear / pinhead glass, including
two coats of enamel paint & primer under coat.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

62

ITEM NO
J-042

DESCRIPTION
Supplying & fixing casement fasteners Iron oxidized .

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT
nr

63

ITEM NO

DESCRIPTION

UNIT

J-043

Supplying & fixing door, window frames new, measured


length of timber treated kempas, 95mm x 45mm.

Supplying & fixing door, window frames new, measured


length of timber treated kempas, 95mm x 70mm.

J-044

J-045

J-046

Supplying & fixing door/ window frames with new jack


timber 95mm x 45mm.

Supplying & fixing door/ window frames with new jack


timber 95mm x 70mm.

Supplying & fixing door, window 28mm thick new sash


glazed or panelled cl.1 timber.

m2

Supplying & fixing door, window 28mm thick sash new


glazed or panelled Jack or special.

m2

J-049

Glass panes plain / pinhead 3mm replaced complete.

m2

J-050

Glass panes plain / pinhead 4.6mm replaced complete.

m2

J-051

Security weld mesh in open type buildings in GI weld mesh


50mm x 50mm SWG 10, welded on 40mm x 40mm x 5mm
MS angle frame complete with application of two coats
enamel paint over two coats of anticorrosive paint (using
available weld mesh ).

J-047

J-048

J-052

J-053

J-054

Fixing security weld mesh on existing window frames


complete with class 1 timber beadings, and applying two
coats paint to match the existing including two coats of
enamel paint & primer under coat.
Supply and fix plywood door sash approved quality
including of oxidized heavy duty furniture etc. (Painting &
locks measured separately).
Anodized aluminium louvers panel fixed to aluminium
window or doors with aluminium architectural sections with
10 - 15 micron coating including all necessary fittings etc.
(Aluminium window or door measured separately).(The used
sections are DG01, DG101, A -110 -AT)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

m2

m2

64

ITEM NO

DESCRIPTION

J-055

Anodized aluminium hinged type sash door with aluminium


architectural sections with 10 - 15 micron coating glazed and
panelled with 3mm plastic coated ply board to both sides at
bottom and 4.6mm thick glass at top.Including door lock etc.
(The used sections are 100D 3105, 100D 103, 100D
101,100D 201, 100D 301, 100D 401, 100D 501,
70SM 1011)

UNIT

m2
J-056

J-057

Anodized aluminium glazed window with openable sash with


aluminium architectural sections with 10 - 15 micron coating
with 4.6 mm thick glass including all necessary rubber
beading, rawl plug & window lock etc.(The used sections are
CA 1009, CA 1010, CA 2005,70SM 1011)

m2

Anodized aluminium glazed sliding window with aluminium


architectural sections with 10 - 15 micron coating with
4.6mm thick glass including all necessary rubber beading,
rawl plug & window lock etc.(The used sections are 70S
1001, 70S 1101 -1, 70S 1201 - 1, 70S 1401,70S 1501, 70S
1601, 70S 1701)
m2

J-058

TYPE-01 Anodized Aluminium partition with aluminium


architectural sections with 10 - 15 micron coating glazed and
panelled with 3mm , plastic coated ply board to both sides,at
bottom and 4.6mm thick glass at top.(The used section SPR
105, SPR 106, SPR 110, SPR 107, SPR 4521)
m2

J-058a

TYPE-02 Anodized Aluminium partition with aluminium


architectural sections with 10 - 15 micron coating glazed and
panelled with 3mm , plastic coated ply board to both sides,at
bottom and 4.6mm thick glass at top.(The used section SPR
105, SPR 106, SPR 110, SPR 107, SPR 4521)
m2

J-058b

TYPE -03 Anodized Aluminium partition with aluminium


architectural sections with 10 - 15 micron coating glazed and
panelled with 3mm , plastic coated ply board to both sides,at
bottom and 4.6mm thick glass at top.(The used section SPR
105, SPR 106, SPR 110, SPR 107, SPR 4521)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

65

ITEM NO

DESCRIPTION

J-058c

TYPE -04 Anodized Aluminium partition with aluminium


architectural sections with 10 - 15 micron coating glazed and
panelled with 3mm , plastic coated ply board to both sides,at
bottom and 4.6mm thick glass at top.(The used section SPR
105, SPR 106, SPR 110, SPR 107, SPR 4521)

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m2

66

ITEM NO

DESCRIPTION

J-059

Anodized aluminium glazed sliding type door sash with


aluminium architectural sections with 10 - 15 micron coating
glazed and panelled with 3mm plastic coating ply board to
both sides,at bottom and 4.6mm thick glass at top ,including
door lock.(The used section 70S - 1002 -1, 70S 1102 -1, 70S
1701 A, 70S 1402-1, 70S - 1801, 70S 1501, 70S 1202 - 1)

UNIT

m2
J-060

Powdercoated aluminium louvers panel fixed to aluminium


window or doors with aluminium architectural sections with
60-80 micron coating including all necessary fittings etc.
(Aluminium window or door measured separately).(The used
sections are DG01, DG101, A -110 -AT)
m2

J-061

Powder coated aluminium hinged type sash door with


aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm plastic coated ply board to
both sides at bottom and 4.6mm thick glass at top.Including
door lock etc.(The used sections are 100D 3105, 100D 103,
100D 101,100D 201, 100D 301, 100D 401, 100D 501,70SM
1011)
m2

J-062

Powder coated aluminium glazed window with openable sash


with aluminium architectural sections with 60 - 80 micron
coating with 4.6 mm thick glass including all necessary
rubber beading, rawl plug etc.(The used sections are CA
1009, CA 1010, CA 2005,70SM 1011)
m2

J-063

J-064

Powder coated aluminium glazed sliding window with


aluminium architectural sections with 60 - 80 micron coating
with 4.6mm thick glass including all necessary rubber
beading, rawl plug & window lock etc.(The used sections are
70S 1001, 70S 1101 -1, 70S 1201 - 1, 70S 1401,70S 1501,
70S 1601, 70S 1701)

m2

TYPE-01 Powder coated aluminium


partition with
aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm , plastic coated ply board to
both sides,at bottom and 4.6mm thick glass at top.(The used
section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)
m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

67

ITEM NO

DESCRIPTION

J-064a

TYPE-02 Powder coated aluminium partition with


aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm , plastic coated ply board to
both sides,at bottom and 4.6mm thick glass at top.(The used
section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

UNIT

m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

68

ITEM NO

DESCRIPTION

J-064b

TYPE -03 Powder coated aluminium partition with


aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm , plastic coated ply board to
both sides,at bottom and 4.6mm thick glass at top.(The used
section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)

UNIT

m2
J-064c

TYPE -04 Powder coated aluminium partition with


aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm , plastic coated ply board to
both sides,at bottom and 4.6mm thick glass at top.(The used
section SPR 105, SPR 106, SPR 110, SPR 107, SPR 4521)
m2

J-065

Powder coated aluminium glazed sliding type door sash with


aluminium architectural sections with 60 - 80 micron coating
glazed and panelled with 3mm plastic coating ply board to
both sides,at bottom and 4.6mm thick glass at top ,including
door lock.(The used section 70S - 1002 -1, 70S 1102 -1, 70S
1701 A, 70S 1402-1, 70S - 1801, 70S 1501, 70S 1202 - 1)
m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

69

ITEM NO

DESCRIPTION

UNIT

SECTION X - PAINTER AND DECORATOR


P-001

P-002

Prepare and apply one coat of alkali resisting primer and two
coats of emulsion paint to walls.

m2

Paint emulsion after cleaning and preparing surface, one coat.


m2

P-003

P-004

Paint emulsion after cleaning and preparing surface, two


coats.
Paint enamel two coats after cleaning and preparing surface
in new wood work inclusive of one coat of primer.

m2

m2

P-005

Paint enamel after cleaning and preparing surface, one coat.

m2

P-006

Floor paint after cleaning and preparing surface, one coat.

m2

P-007

Paint enamel after cleaning and preparing surface, two coats.


m2

P-008

Floor paint after cleaning and preparing surface, two coats.

m2

P-009

Paint removed from any surfaces with blow lamp.

m2

P-010

Paint anticorrosive on steel work after removing scales and


wire brushing, one coat.

m2

Paint anticorrosive on steel work after removing scales and


wire brushing, two coats.

m2

Apply two coats of varnish after sand papering and cleaning


surface.

m2

P-011

P-012

P-013

P-014

Apply one coat of polyurethane varnish


surfaces after sand papering and cleaning.

for old wooden

Apply one coat of weathershield paint on external surfaces


after cleaning and preparation.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

70

ITEM NO

DESCRIPTION

P-015

Apply two coats of weathershield paint on external surfaces


after cleaning and preparation.

P-016

Apply one coat of primer and two coats of weatheshild paint


for new walls.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

m2

m2

71

ITEM NO

DESCRIPTION

UNIT

P-017

Apply white or colour washing to walls, one coat.

m2

P-018

Apply white or colour washing to walls one coat after


patching up and preparing surface.

m2

Apply two coats of white or colour washing to walls after


scraping to original plaster and patching up.

m2

P-020

White washing to ceiling and soffits one coat.

m2

P-021

White washing to ceiling and soffits two coats.

m2

P-022

Apply two coats of roofing paint on roof after cleaning.

m2

P-019

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

72

ITEM NO

DESCRIPTION

UNIT

SECTION XI - ROOFER
R-001

R-002

R-003

R-004

R-005

R-006

R-007

Supplying and fixing new asbestos roofing sheets confirming


to SLS 9 on existing framework with new nut and bolts etc.
(Frame work measured separately).
Supplying & fixing 0.47mm thick Zn/Al. roofing sheets with
self drilling screws (fasteners) on existing frame work
(Frame work measured separately).
Supplying & fixing C - purlin 100 mm x 50 mm x 12 mm,
2mm thick including prepare & apply 2 coats of anticorrosive
paint, necessary nut & bolts 6mm thick cleat and welding
works etc.

m2

m2

Supplying & fixing 0.47mm thick Zn / Al Ridge cap with


self drilling Screws (Fasteners) minimum girth 470mm.

Asbestos roofing sheets replacing with new sheets on


existing frame work.

m2

Ceiling 19mm thick Lunumidella, tongued and grooved


under side of rafters, on existing timber frame work.

m2

Ceiling, asbestos, flat fixed with wire nails to 100mm x


50mm joists & 50mm x 50mm bearers @ 0.6m c/c in cl.1
timber including 35mm x 12mm beadings and 50mm x
35mm cove mouldings of approved timber. Rate to include
one coat of primer 2 coats of emulsion paint to underside of
ceiling and two coats of wood preservative(stain) to timber
frame work.
m2

R-008

Ceiling, asbestos, flat fixed with wire nails to 100mm x


50mm joists,1.2m c/c & 50mm x 50mm bearers at 0.6m c/c
in cl. 1 timber including 35mm x 12mm beadings and 50mm
x 35mm cove mouldings of approved timber. Rate to include
2 coats of wood preservative (stain) on timber frame work.
m2

R-009

Ceiling flat asbestos under side of rafters, timber frame work


measured separately, rate includes for clout headed nails,
screws, beadings and mouldings.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

73

ITEM NO

DESCRIPTION

R-010

Ceiling flat asbestos under side of steel purlins ,50mm x


50mm cl. 1 timber frame not more than 1.2m x 0.6m
crs.includes for clout headed nails, screws, beadings and
mouldings and 6mm dia. mild steel hanging hooks. Rate to
include for application of wood preservative (stain)timber
frame.

R-011

R-012

R-013

R-014

R-015

R-016

R-017

R-018

R-019

Ceiling flat Lunumidella 19mm thick tongued and grooved


complete with timber frame cl.1 100mm x 50mm joists at
0.6m crs. Rate to include for application of wood
preservative on timber frame work twice. (Painting measured
separately).
Down pipes pvc 90mm dia. supplied and fixed with brackets
not exceeding 1.2m well secured to walls with plastic rawl
plugs. Rate includes for specials.
Down pipes GI G24, 100mm x 75mm with 20mm x 3mm
hoop iron brackets not exceeding 1.2m crs. all other sides and
brackets applied with 2 coats anticorrosive paint, rate
includes for specials.
Down pipes Zn/Al 0.47mm thick 100mm X 100mm with
brackets not exceeding 1.2m crs. of the pipe, rate includes for
specials.
Gutters GI G22, 150mm with 12mm x 6mm flat iron
brackets not exceeding 0.6m crs. all sides and brackets
applied with two coats of anticorrosive paint, rate includes
for specials.
Gutters 0.47mm thick Zn /Al 457mm girth with brackets not
exceeding 0.6m crs. rate includes for specials.
Gutters pvc square type 150mm with PVC brackets not
exceeding 225mm fixed to valance board using 20mm nails,
rate includes for specials.

UNIT

m2

m2

Plaster bands in 1:1:5 cement, lime and sand to tiled roof


coloured to match tiles.

Ridging asbestos close fitting type pairs fixed with necessary


bolts.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

74

ITEM NO

DESCRIPTION

UNIT

R-020

Ridging calicut pattern tile bedded in cement, lime and sand


motar 1:1:4 coloured to match tiles.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

75

ITEM NO

DESCRIPTION

R-021

Steel sections 2/ 62mm x 62mm x 6mm used in gable rafters


purlins etc.complete with fixing, bolts, 2 coats of
anticorrosive paint and providing cleats where necessary .
(Concrete pad paid separately)

R-022

UNIT

Wood preservative (stain) applying one coat on roof structure


in asbestos roof measured in plan area.

m2

Wood preservative (stain) applying one coat on roof structure


for calicut tile roof, measured in plan area.

m2

Wood preservative (stain) applying two coats on roof


structure for asbestos roof measured in plan area.

m2

Wood preservative (stain) applying two coats on roof


structure for calicut tile roof measured in plan area.

m2

Tiles calicut (available) laying on roof (For scattered laying)


up to 10 tiles per building only.

nr

Tiles calicut (new) supplying and laying ( scattered laying) up


to 25 tiles per building only.

nr

Tiles calicut shifting and relaying after cleaning (For


measurements of area not exceeding 25 tiles).

nr

R-029

Tiles, calicut pattern, supplied and laid in any building.

m2

R-030

Timber 50mm x 25mm reepers class 1 replacing with new


including
application
of
two
coats
of
wood
2
preservative(stain) (Only up to 4.60m of roof area).

R-023

R-024

R-025

R-026

R-027

R-028

R-031

R-032

Timber 50mm x 25mm reepers class 1 supplied and fixed


including application of two coats of wood preservative
(stain) (only up to 4.6m2 of roof area).
Timber 50mm x 50mm battens class 1 replacing with new
including
application
of
two
coats
of
wood
preservative(stain) (Only up to 4.6m2 of roof area).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

76

ITEM NO

DESCRIPTION

R-033

Timber 50mm x 50mm battens class 1 supplied and fixed


including
application
of
two
coats
of
wood
preservative(stain) (only up to 4.6m2 of roof area).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

77

ITEM NO

DESCRIPTION

R-034

Timber 50mm x 100mm joists/ rafters class 1 replacing with


new including application of two coats wood of
preservative(stain) ( only up to 4.6m2 of roof area).

R-035

R-036

R-037

R-038

R-039

R-040

R-041

R-042

R-043

R-044

R-045

Timber 50mm x 100mm joists/ rafters class 1 supplied and


fixed including application of two coats of wood preservative
(stain) ( only up to 4.6m2 of roof area).
Timber beams, any size class 1 supplied and fixed including
application of two coats of wood preservative(stain) (Only up
to 4.6m2 of roof area).
Timber boarding cl.1, 20mm to 25mm thick for valley
gutters, flashings etc, inclusive of apply two coats of wood
preservative(stain)( Only up to 4.6m2 of roof area).

UNIT

m3

m2

Valance boards beaded 225mm x 20mm thick supplying and


fixing Ginisapu, including one coat of primer and two coats
of enamel paint (Flat iron bracket measured separately) .

Valley gutters and flashing in GI sheets G22, including


application of two coats of hot tar and blinding with sand
(timber board measured separately) 900mm wide.

Ridge tiles (available) laid on roof, 1:3 cement and sand


bedding and coloured to match tiles.

Timber (available), cleaned and fixed on roof, size 50mm x


25mm.

Timber (available), cleaned and fixed on roof, size 50mm x


50mm.

Timber (available), cleaned and fixed on roof, size 100mm x


50mm.

Timber (available), cleaned and fixed on roof, size 100mm x


75mm.

Timber (available), cleaned and fixed on roof, size 125mm x


50mm.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

78

ITEM NO

DESCRIPTION

R-046

Roof trusses available cleaned and placed in position with


supplying necessary bolts and templates, 6m (20 L.ft) to 7.2m
( 24 L.ft) spans.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

79

ITEM NO

DESCRIPTION

R-047

Roof trusses available cleaned and placed in position with


supplying necessary bolts and templates, 7.6m (25 L.ft) to
8.7m (29 L.ft) span.

R-048

R-049

R-050

Roof trusses available cleaned and placed in position with


supplying necessary bolts and templates, 9.1m (35L.ft)and
above up to 12.2m (40 L.ft) span.
Fixing available steel purlins on roofs structures complete
with necessary bolts, welding, cleaning and painting two
coats anticorrosive paints etc.

UNIT

nr

nr

Roof asbestos. 62mm x 62mm x 6mm MS purlins not


exceeding 1.35m crs.complete with necessary bolts / welds
GI roofing bolts at not more than 0.55m crs. on every purlin,
applied with two coats of anticorrosive paint and the
underside of sheets applied with two coats of lime wash.
Rate included 20mm x 6mm flat iron brackets for fixing
valance board at 0.6m c/c.
m2

R-051

R-052

R-053
R-054

75mm x 75mm gauge 17 welded wire mesh supplied and laid


under the roof as directed.

m2

Laminated aluminium foil, 4mm thick double side double


bubble insulation layer, supplied and laid under the roof as
directed. (Ultra bubble reflective layer)

m2

Mineral fiber board ceiling suspended type with T and L


ceiling sections complete as per detailed drawing.

m2

Web truss any span and any pitch with angle iron and mild
/tor steel rate to include two coats of anticorrosive paint and
placing in position in ground floor roof.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

kg

80

ITEM NO

DESCRIPTION

UNIT

SECTION XII - PLASTERER


S-001

S-002

S-003

S-004

S-005

S-006

S-007

S-008

S-009

S-010

S-011

S-012

Black board plastering with 1:3 cement and sand finished


smooth with black cement floating including moulding at
perimeter 20mm thick.

m2

16mm thick 1:1:5 cement, lime and sand plastering to walls


finished smooth with lime putty.

m2

1:1:5 cement, lime and sand plaster reveals 35mm to 150mm


wide finished smooth with lime putty.

Cement, lime and sand plaster breaking in damaged areas and


replastering with 20mm thick 1:1:5 cement, lime and sand,
finished smooth with lime putty.
Cement and sand 1:3 plaster finished smooth with lime putty
on exposed faces of concrete surfaces and soffits, 10mm
thick.

m2

m2

16mm thick cement and sand 1:5 plaster finished semi-rough


with wooden float.

m2

16mm thick cement, lime and sand 1:1:5 plaster finished


semi-rough with wooden float.

m2

1:1:5 cement, lime and sand plaster to reveals 35mm to


150mm wide finished semi-rough.

Cement and sand rough plaster breaking in damaged areas


and replastering with 1:1:5 cement, lime and sand plaster,
finished semi-rough with wooden float.
20mm thick damp proof course in 1:2 cement and sand
trowelled smooth and apply two coats of hot tar blinded with
sand.
Plinth plaster 12mm thick in 1:3 cement and sand finished
smooth with gray cement floating.
Plinth plaster 12mm thick in 1:3 cement and sand finished
smooth with coloured cement floating.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

m2

m2

m2

m2

81

ITEM NO

DESCRIPTION

UNIT

S-013

Rendering cement and sand 1:3, 20mm thick, finished


smooth with gray cement floating on walls.

m2

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

82

ITEM NO

S-014

DESCRIPTION

A) Tiles glazed of approved pattern and colour with all specials


supplied and fixed to walls including raking plaster and
bedding in cement mortar 1:3, joints finished with tile grout
to match colour of tiles and cleaning. (Tile rate not included)

UNIT

m2

B) Add only the cost of tile + overhead and profit per m2 (Wall
Tile) for the above rate.
* Total wall tiling rate A + B

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

83

ITEM NO

DESCRIPTION

UNIT

SECTION XIII - PLUMBER


Note
1.
2.
W-001

W-002

W-003

All Brass taps, Ball valves, Gate valves, Stop valves, etc.
Peglar or equivalent.
All semi- luxury taps Momali or equivalent.
Supplying & fixing 20mm(1/2") dia. bidet spray approved
best quality.(Chromium plated)

nr

Approved cistern plastic supplied and fixed with 20mm(1/2")


flexible hose.

nr

A) Approved Closet , fixed with working order including


supply 20mm(1/2")dia. Brass chromium plated angle valve
and flexible hose. (Closet rate not included.)

nr

B) Add only cost of the complete closet + over head and profit
per one set for the above rate.
* Supplied and fixed approved closet rate A + B
W-004

W-005

W-006

W-007

W-008

Bowl type approved urinal with trap and urinal flush valve
complete to working order.
Approved closet squatting foot rest type (Orissa pan) with
trap, supplied and fixed to working order, including
connection to sewer line. Rate includes for breaking floor and
concreting, cement rendering in damaged areas.
Approved new closet squatting foot rest type (Orissa pan)
with trap, supplied and fixed to working order including
connection to sewer line.
Supplied and fixed mirror for bathroom 450mm x 600mm
size approved quality with shelf, screws, plugs etc.
Approved sink stainless steel with single drain board with
chromium plated wastewater chain, stay & waste plug (tap,
brackets, water , waste water connection & brick work
measured separately).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

nr

nr

nr

nr

84

ITEM NO

DESCRIPTION

W-009

Approved ceramic sink 600mm x 375mm x 175mm overall


size complete with waste plug, chromium plated waste chain
& stay (tap, water connection, waste water connection &
brick work measured separately).

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

85

ITEM NO

DESCRIPTION

W-010

Approved sink ceramic laboratory supplying and fixing


complete with waste, chromium plated waste chain, stay and
waste plug. (tap, water & waste water connection, brick work
measured separately).

W-011

W-012

Supplying and fixing approved corner wash basin ceramic


with 20mm(1/2") dia. chromium plated pillar tap, waste plug,
chain and stay.(water connection and wastewater connection
measured separately).
A) Fixing wash basin suppled with 20mm(1/2") dia. Brass
chromium plated pillar tap, waste plug, chain and stay.(Water
connection and waste water connection measured separately).
(Wash basin rate not included).

UNIT

nr

nr

nr

B) Add only cost of the complete wash basin + over head and
profit.(without taps and waste) per one set for the above rate.
* Supplied and fixed approved wash basin rate A + B
W-013

Removing and refixing available wash basin.

W-014

Stand post with 0.9m x 0.9m x 0.15m grade 20 concrete base


and 0.15m x 0.15m x 0.75m RCC post, 20mm(1/2") plastic
bib tap. Inclusive of 20mm PVC pipe connection. Concrete
base and post to be rendered with 1:3 cement and sand
finished smooth. (PVC supplied pipe measured separately).

nr

nr
W-015

W-016

W-017

Tank water storage ,1.8m3 composite brick and reinforced


concrete, erected 3m above ground level. (Trestle measured
separately, As per detail drawing).
Supply and install 1000 L capacity (confirming to SLS 1174)
water tank made of polymer materials of approved quality on
sand bed. Rate for only water tank. PVC pipes, valves,
fittings measured separately.
Supply and install 2000 L capacity (confirming to SLS 1174)
water tank made of polymer materials of approved quality on
sand bed. Rate for only water tank. PVC pipes, valves,
fittings measured separately.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

nr

nr

nr

86

ITEM NO

DESCRIPTION

W-018

Supply and install 500 L capacity (confirming to SLS 1174)


water tank made of polymer materials of approved quality on
sand bed. Rate for only water tank. PVC pipes, valves,
fittings measured separately.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

UNIT

nr

87

ITEM NO

DESCRIPTION

UNIT

W-019

Supplying & fixing rubber rings in outlets for wash basin,


sink etc.

nr

W-020

W-021

W-022

W-023

W-024

W-025

W-026

W-027

W-028

W-029

W-030

Supplying and fixing 20mm(1/2") dia. approved chromium


plated heavy quality swan neck type pillar tap with 01 No.
P.V.C. faucet socket to existing wash basin/sink.
Supplying and fixing 20mm(1/2") dia. approved brass heavy
quality, chromium plated bib tap with 20mm(1/2") dia. P.V.C.
valve faucet socket.
Supplying and fixing 20mm(1/2") dia. approved brass heavy
quality chromium plated Angle Value with 20mm(1/2") dia.
P.V.C. faucet socket.

nr

nr

nr

Supplying and fixing 20mm(1/2") dia. approved plastic bib


tap with 1 No.P.V.C faucet socket.

nr

Supplying & fixing 20mm(1/2" dia.),150mm approved


chromium plated shower rose.

nr

Supplying and fixing 20mm(1/2") dia. approved shower rose


chromium plated best quality Indian or equalant.

nr

Pipes PVC supplied and laid with specials, size 50mm dia. in
wastes of sinks. Type 600.

Pipes PVC supplied and laid with specials, size 50mm dia.
rate includes for cutting trenches, testing and backfilling.
(Type 1000) depth of the trench not less than 450mm.
Pipes PVC type 600 supplied and laid with specials, size
40mm dia. in waste of wash basins.
Pipes PVC type 1000 supplied and laid with specials, size
40mm dia. Rate includes for cutting trenches, testing and
backfilling. Depth of the trench not less than 450mm.
Pipes PVC supplied and laid with specials, size 32mm dia.
(Type 1000) rate includes for cutting trencthes,testing and
backfilling, depth of the trench not less than 450mm.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

88

ITEM NO

DESCRIPTION

UNIT

W-031

Pipes PVC supplied and laid with specials, size 20mm dia.
type 1000 rate includes for cutting trenches, testing and back
filling. Depth of the trench not less than 450mm.

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

89

ITEM NO

DESCRIPTION

UNIT

W-032

Pipes pvc supplied and laid with specials, size 63mm dia. in
waste water lines, vent pipes etc. (Type 400).

Pipes pvc supplied and laid with specials, size 63mm dia.
(Type 1000).

W-033

W-034

W-035

W-036

W-037

W-038

W-039

W-040

W-041

W-042

W-043

W-044

W-045

Pipes PVC supplied and laid with specials, size 25mm dia.
type 1000 rate includes for cutting trenches, testing and
backfilling. Depth of the trench not less than 450mm.
Valve chamber 225mm x 225mm x 225mm in 1:2:4(20mm)
concrete, complete with RCC lid, necessary lifting
hooks,R113 cement rended in innner surfaces.

nr

Gate valve ,brass, supplied and fixed, size 20mm dia. heavy
quality.

nr

Gate valve, brass, supplying and fixing, size 32mm dia.


heavy quality.

nr

Gate valve brass, supplied and fixed, size 40mm dia. heavy
quality.

nr

Gate valve brass, supplied and fixed, size 50mm dia. heavy
quality.

nr

Gate valve brass, supplied and fixed, size 63mm dia. heavy
quality.

nr

Ball cock brass supplied and fixed, size 20mm dia. heavy
quality.

nr

Ball cock brass supplied and fixed, size 25mm dia. heavy
quality.

nr

Ball cock brass k supplying and fixing, size 32mm dia. heavy
quality.

nr

Ball cock brass, supplying and fixing, size 40mm dia. heavy
quality.

nr

Ball cock plastic supplied and fixed, size 25mm dia.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

90

ITEM NO

DESCRIPTION

UNIT

W-046

Ball cock plastic supplied and fixed, size 20mm dia.

nr

W-047

Ball cock plastic supplying and fixing, size 32mm dia.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

91

ITEM NO

DESCRIPTION

UNIT

W-048

Ball valve ,brass, supplied and fixed, size 20mm dia.

nr

W-049

Ball valve brass supplying and fixing, size 25mm dia.

nr

W-050

Ball valve ,brass, supplying and fixing, size 32mm dia.

nr

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

92

NG VAT
RATE
EXCLUDING
VAT

10,556.00

10,277.00
1,340.00

797.00

4,792.00

1,252.00

1,449.00

1,941.00

7,562.00
9,168.00

9,980.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

93

RATE
EXCLUDING
VAT

460.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

94

RATE
EXCLUDING
VAT

585.00

708.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

95

RATE
EXCLUDING
VAT

20,303.00

16,936.00

15,520.00

11,911.00

11,466.00

232.00

219.00

1,303.00

1,218.00

1,279.00
1,590.00

991.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

96

RATE
EXCLUDING
VAT

36,009.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

97

RATE
EXCLUDING
VAT

645.00

825.00

1,754.00

1,512.00
.

2,462.00

3,106.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

98

RATE
EXCLUDING
VAT

2,629.00

3,229.00

16,778.00

17,443.00

18,813.00

18,048.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

99

RATE
EXCLUDING
VAT

301.00

332.00

127.00

119.00

120.00

101.00

111.00

118.00

163.00

223.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

100

RATE
EXCLUDING
VAT

276.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

101

RATE
EXCLUDING
VAT

60.00

90.00

120.00

2,279.00

2,849.00

3,418.00

239.00

982.00

1,222.00

7,848.00

8,251.00

8,854.00

1,107.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

102

RATE
EXCLUDING
VAT
1,661.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

103

RATE
EXCLUDING
VAT

142.00

213.00

30.00
23.00
443.00
277.00
44.00
15.00

134.00

201.00

173.00
238.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

104

RATE
EXCLUDING
VAT

603.00

116.00

897.00

1,199.00

1,616.00

1,190.00

995.00

1,386.00

1,972.00

2,567.00

701.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

105

RATE
EXCLUDING
VAT

807.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

106

RATE
EXCLUDING
VAT
532.00

297.00

594.00

832.00

1,929.00

238.00

24.00

334.00

589.00

2,087.00

353.00
3,691.00
2,061.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

107

RATE
EXCLUDING
VAT

1,705.00

1,379.00

1,503.00

1,241.00

924.00

662.00
56.00
98.00

1,263.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

108

RATE
EXCLUDING
VAT

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

109

RATE
EXCLUDING
VAT

192.00

682.00

579.00
105.00

333.00

1,684.00

761.00

362.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

110

RATE
EXCLUDING
VAT

36.00
3,813.00
2,706.00

6,056.00
3,832.00

8,776.00
6,551.00

12,607.00
10,382.00

17,551.00
15,326.00

21,383.00
19,158.00

1,255.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

111

RATE
EXCLUDING
VAT

1,452.00

2,390.00

2,838.00

502.00

18.00

30.00

9,908.00

8,401.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

112

RATE
EXCLUDING
VAT

8,845.00

11,625.00

15,577.00

8,462.00

204.00

211.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

113

RATE
EXCLUDING
VAT

654.00
911.00
654.00

763.00

847.00

2,464.00

2,548.00

560.00

12,010.00

3,153.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

114

RATE
EXCLUDING
VAT

18,771.00

4,199.00

1,202.00

79,018.00

41,402.00

106,979.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

115

RATE
EXCLUDING
VAT
913.00

799.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

116

RATE
EXCLUDING
VAT

87,610.00

95,167.00

8,274.00

122,932.00

9,807.00

177,140.00

13,908.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

117

RATE
EXCLUDING
VAT

al Installations.

Orange Industrial or
Year warranty period.

quality and should have

afety Wire Provided to

1,519.00

1,607.00

2,335.00

3,064.00

3,792.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

118

RATE
EXCLUDING
VAT

4,520.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

119

RATE
EXCLUDING
VAT

1,321.00

1,762.00

2,204.00

2,646.00

3,088.00

1,321.00

1,762.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

120

RATE
EXCLUDING
VAT

2,204.00

2,646.00

3,088.00

1,321.00

1,762.00

2,204.00

2,497.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

121

RATE
EXCLUDING
VAT

1,658.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

122

RATE
EXCLUDING
VAT

1,596.00

4,388.00

6,041.00

7,694.00

2,708.00

2,708.00

1,417.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

123

RATE
EXCLUDING
VAT

1,623.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

124

RATE
EXCLUDING
VAT

1,166.00

1,391.00

1,597.00

1,685.00

2,410.00

3,352.00

3,861.00

4,586.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

125

RATE
EXCLUDING
VAT

1,399.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

126

RATE
EXCLUDING
VAT

1,838.00

2276

2,567.00

3,154.00

1,399.00

1,838.00

2,276.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

127

RATE
EXCLUDING
VAT

2,715.00

3,154.00

1,399.00

1,838.00

2,276.00

2,614.00

1,737.00

1,675.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

128

RATE
EXCLUDING
VAT

4,479.00

6,171.00

7,863.00

2,787.00

2,787.00

1,496.00

1,702.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

129

RATE
EXCLUDING
VAT

1,244.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

130

RATE
EXCLUDING
VAT

1,469.00
127.00
180.00

259.00

368.00

499.00

790.00

1,151.00

1,717.00

197.00

250.00

329.00

439.00

672.00

1,075.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

131

RATE
EXCLUDING
VAT
1,593.00
2,466.00

684.00

963.00

1,488.00

2,131.00

3,723.00

4,446.00

803.00

1,136.00

1,773.00

2,574.00

3,723.00

4,889.00

150.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

132

RATE
EXCLUDING
VAT
198.00

252.00

364.00

530.00

837.00

1,057.00

142.00

195.00

274.00

384.00

522.00

769.00

1,120.00

1,686.00

213.00

266.00
Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

133

RATE
EXCLUDING
VAT

345.00

454.00

695.00

1,054.00
1,563.00

2,436.00

707.00

943.00

1,452.00

2,096.00

3,244.00

4,410.00

826.00

1,116.00

1,737.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

134

RATE
EXCLUDING
VAT
2,538.00

3,686.00

4,852.00
165.00
214.00
268.00
380.00
553.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

135

RATE
EXCLUDING
VAT
860.00
1,080.00

4,965.00

4,107.00

2,982.00

3,947.00

1,054.00

1,268.00

1,590.00

2,232.00

786.00

1,161.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

136

RATE
EXCLUDING
VAT

1,536.00

2,393.00

3,143.00

776.00
1,598.00

2,300.00

2,032.00

4,336.00

4,068.00

1,074.00

1,208.00

2,252.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

137

RATE
EXCLUDING
VAT

1,101.00

2,895.00

3,217.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

138

RATE
EXCLUDING
VAT

3,538.00

1,452.00

1,388.00

1,783.00

1,718.00

1,504.00

1,568.00
542.00
1,199.00
1,029.00

6,992.00

6,762.00

14,219.00
541.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

139

RATE
EXCLUDING
VAT
563.00

638.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

140

RATE
EXCLUDING
VAT

605.00
648.00
745.00

514.00

723.00

1,991.00

2,885.00

9,200.00

10,850.00

12,500.00

14,303.00

16,065.00

18,321.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

141

RATE
EXCLUDING
VAT

11,653.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

142

RATE
EXCLUDING
VAT

13,303.00

14,953.00

16,757.00

18,518.00

20,774.00

17,296.00

34,616.00
19,128.00

2,408.00

2,697.00
4,922.00
5,607.00
5,129.00
7,293.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

143

RATE
EXCLUDING
VAT
9,154.00
11,693.00

34,272.00

39,179.00

25,508.00

30,961.00

48,601.00

55,962.00

55,130.00

63,305.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

144

RATE
EXCLUDING
VAT

43,844.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

145

RATE
EXCLUDING
VAT

44,969.00

61,203.00

63,160.00

91,240.00
1,468.00
3,225.00
2,507.00
5,057.00
1,618.00
2,625.00

189.00

205.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

146

RATE
EXCLUDING
VAT

373.00

255.00

501.00

284.00

837.00

473.00
214.00

556.00

8,760.00

9,451.00

12,992.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

147

RATE
EXCLUDING
VAT

15,765.00

18,142.00

14,748.00

16,002.00

12,163.00

14,754.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

148

RATE
EXCLUDING
VAT

11,868.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

149

RATE
EXCLUDING
VAT

11,903.00

264.00

1,435.00
227.00

1,724.00

2,082.00

3,212.00
1,086.00
4,871.00

7,726.00

7,977.00

5,215.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

150

RATE
EXCLUDING
VAT

6,659.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

151

RATE
EXCLUDING
VAT

5,522.00

5,784.00

1,000.00

1,455.00

1,086.00

1,466.00

6,247.00

8,492.00

15,349.00

15,008.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

152

RATE
EXCLUDING
VAT
174.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

153

RATE
EXCLUDING
VAT

850.00

1,284.00

918.00

1,294.00

5,112.00

7,251.00
1,888.00
2,246.00

3,134.00

1,474.00

3,874.00

14,410.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

154

RATE
EXCLUDING
VAT

16,109.00

12,088.00

9,041.00

4,412.00

4,708.00

4,890.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

155

RATE
EXCLUDING
VAT

6,004.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

156

RATE
EXCLUDING
VAT

7,031.00

15,517.00

17,347.00

12,855.00

9,608.00

4,686.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

157

RATE
EXCLUDING
VAT

5,014.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

158

RATE
EXCLUDING
VAT

5,219.00

6,392.00

7,536.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

159

RATE
EXCLUDING
VAT

379.00

132.00

254.00

623.00
261.00
282.00

599.00
643.00
179.00

267.00

399.00

355.00

248.00

141.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

160

RATE
EXCLUDING
VAT
274.00

430.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

161

RATE
EXCLUDING
VAT
17.00

40.00

80.00
46.00
81.00
288.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

162

RATE
EXCLUDING
VAT

1,063.00

2,415.00

1,447.00

1,175.00

1,221.00

1,392.00

3,006.00

2,620.00

1,525.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

163

RATE
EXCLUDING
VAT

2,523.00

3,209.00

499.00

1,567.00

1,391.00

1,401.00

1,309.00

749.00

99.00

1,005.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

164

RATE
EXCLUDING
VAT
527.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

165

RATE
EXCLUDING
VAT

3,000.00

82.00

98.00

124.00

186.00

5.00

61.00

22.00
817.00

101.00

96.00

240.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

166

RATE
EXCLUDING
VAT

237.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

167

RATE
EXCLUDING
VAT

687.00

642.00

128,474.00

2,658.00

979.00

1,127.00

342.00

35.00

38.00

171.00

171.00

171.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

168

RATE
EXCLUDING
VAT

7,308.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

169

RATE
EXCLUDING
VAT

8,442.00

9,576.00

247.00

2,263.00

205.00

561.00
2,350.00

278.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

170

RATE
EXCLUDING
VAT

922.00

580.00

196.00

747.00

861.00

451.00

462.00

157.00

630.00

897.00

484.00

666.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

171

RATE
EXCLUDING
VAT
701.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

172

RATE
EXCLUDING
VAT

1,568.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

173

RATE
EXCLUDING
VAT

1,880.00

4,428.00

2,742.00

5,529.00

8,520.00

6,583.00

2,741.00

6,816.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

174

RATE
EXCLUDING
VAT

12,749.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

175

RATE
EXCLUDING
VAT

8,927.00

10,502.00

6,724.00

1,828.00

6,690.00

62,393.00

16,422.00

28,829.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

176

RATE
EXCLUDING
VAT

9,897.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

177

RATE
EXCLUDING
VAT

171.00

2,727.00

1,900.00

925.00

295.00

1,921.00

3,225.00

573.00

625.00

352.00

494.00

401.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

178

RATE
EXCLUDING
VAT

209.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

179

RATE
EXCLUDING
VAT

480.00

941.00

295.00

2,748.00

2,197.00

4,187.00

4,855.00

8,076.00

10,919.00

1,490.00

2,290.00

3,269.00

5,927.00
522.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

180

RATE
EXCLUDING
VAT
325.00
679.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

181

RATE
EXCLUDING
VAT
2,206.00
3,295.00
4,263.00

Q.S.BRANCH, DEPARTMENT OF ENGINEERING SERVICES, KANDY.

2014

Excluding VAT

182

Anda mungkin juga menyukai