Anoverviewofthetechnologyandopportunities
August15,2013
TableofContents
1.
2.
3.
4.
5.
6.
7.
8.
9.
AirConditioningMarketOverview
WhatisGasCooling?
BenefitsofGasCooling
ReducingElectricDemand
VaporCompressionCycle
NaturalGasCoolingEquipment
NaturalGasCoolingEconomics
NaturalGasCoolingEmissions
Resources
AirConditioning
Airconditioning istheprocessofalteringtheproperties
ofair(primarilytemperatureandhumidity)tomore
favorableconditions.Moregenerally,airconditioning
canrefertoanyformoftechnologicalcooling,heating,
ventilation,ordisinfectionthatmodifiestheconditionof
air.*
Todaywewillfocusonspacecoolingorprocesscooling
* ASHRAE
NaturalGasConsumptionInCanada
2010
EnergyConsumption Terajoules
1,200,000
1,000,000
Other
800,000
600,000
Water
Heat
400,000
200,000
Pulp&Paper
Iron&Steel
Chemicals&
Fertilizer
Appliances
Space
Heat
Other
Health
Education
Retail
Mining
Oil&
Gas
Electric
Power
Offices
Residential
Commercial
Industrial
ElectricPower
EnergyConsumptionforComfortCooling
byBusinessActivity
X1000BTU/SqFt
20
15
EnergyUseIntensity
byMarket
(1000BTU/SqFt)
10
5
0
EverybodyneedsAirConditioning
Source:U.S.DepartmentofEnergy,2011BuildingsEnergyDataBook
EnergyUseinCommercialBuildings
Undistributed
11%
Space Heating
26%
Other
14%
Computers
2%
Ventilation
6%
Cooking
2%
Electronics
3%
Refrigeration
5%
Water Heating
7%
Source:U.S.DepartmentofEnergy,2011BuildingsEnergyDataBook
Lighting
14%
Space Cooling
11%
EnergyUsedforComfortCooling
Natural Gas
5%
Electricity
95%
Mostbuildingsuseelectricairconditioningtoday,but
electriccanbemoreexpensivethanthealternative.
Source:U.S.DepartmentofEnergy,2011BuildingsEnergyDataBook
WhatisGasAirConditioning
GasAirConditioningisanyformofairconditioningthat
usesnaturalgasastheprimarysourceofenergyforany
sortofairconditioningsystem,including:
Humidification
Dehumidification(liquidanddrydesiccant)
Spaceorprocesscooling
Todays focus
Benefitsof
NaturalGasCooling
Internal
External
NaturalGasCooling
InternalBenefits
SaveMoney
ImproveProductivity
AddFlexibilitytoExistingSystem
SaveMoneywithGasCooling
Savemoneyonelectricusagecharges
Saveonelectricdemandcharges
Inthemonthlybill
ReduceWinterdemandpenaltiesfromSummer
Peak
ImproveLoadFactorandreducecostof
electricfromthirdparty
ImproveProductivitywithGasCooling
Comfortableworkersaremoreproductive
Healthyworkerscometowork
% Relative Humidity
H1N1
Influenza
Optimum
Level
HybridChillerApplicationsadd
FlexibilitytotheCoolingPlant
Incorporateelectric&gas
chillersintoacombinedchiller
plant
Installbothunittypesintosystem
50%electric/50%gascapacities
Baseloadchillerbasedonutility
costsortimeofday
Idealforfacilitiesthathave
minimalelectricalservice
NaturalGasCooling
ExternalBenefits
EnvironmentalBenefits
ImproveGridReliability
SourcetoSiteEnergyEfficiency
ElectricgenerationMakeup
GasversusElectricEmissions
Greenhouse Gas emissions are far lower when natural gas is consumed
directly at the site versus purchasing power from a source generator.
Far fewer emissions of NOx, SOx, CO2, Particulates, PM10, VOCs,
Mercury, etc. with natural gas versus electric
ElectricGridReliabilityIsDECLINING
Per IEEE
Outages Greater
than 100 MW
1991-1995
66
41
1996-2000
76
58
2000-2004
156
149
2005-2009
264
349
Starting in 1995, the amortization and depreciation rate has exceeded utility
construction expenditures. In other words, for the past 15 years, utilities have
harvested more than they have planted. The result is an increasingly stressed grid.
Indeed, grid operators should be praised for keeping the lights on, while managing a
system with diminished shock absorbers.
Source: IEEE Web Site
http://spectrum.ieee.org/energy/policy/us-electrical-grid-gets-less-reliable
TransmissionandDistributionCongestion&
Constraintscontinuetoincrease
9,000 MW
Generation:
(Growing)
>
7,000 MW
<
Transmission
& Distribution:
8,000 MW
Load:
(Growing)
(?????)
NaturalGasCooling
ReducingElectricDemand
EnergyDemandProfiles GasChillerforAnnualBaseLoad
100%
80%
60%
Demand
Charge
Penalty
40%
20%
0%
Initial
Natural Gas
Demand
Initial
Electric Demand
w/ Electric Chiller
EnergyDemandProfiles GasChillerforAnnualBaseLoad
100%
80%
60%
Initial
Electric
Demand
40%
20%
Decreased
Electric Demand
w/ Gas Chiller
InstallNaturalGasCooling SizedforAnnualBaseLoad
0%
EnergyDemandProfiles GasChillerforAnnualBaseLoad
100%
Initial
Electric
Demand
80%
60%
More consistent
gas usage year
round
Decreased
Demand
Charge
Penalty
40%
Initial
Natural Gas
Demand
20%
0%
Decreased
Electric Demand
w/ Gas Chiller
NaturalGasCooling
VaporCompressionCycle
VaporCompressionCycle
Cooling
Step1:Refrigerantentersthe
Tower
compressorinalowpressure,low
temperature,gaseousform
Rejected
Step2:Therefrigerantiscompressedto
ahighpressureandtemperature
3
gaseousstate
Hot Refrigerant Vapor
Condenser
Simplified
Fill
aerosol
Can
Heat
Engine
Motor
Turbine
Compressor
Evaporator
Evaporator
Cold Refrigerant Vapor
Can heats
up
Load
Heat
VaporCompressionCycle
Step3:Thehighpressureandtemperaturegas Cooling
Tower
entersthecondenserwhereitchangesphase
fromthehighpressureandtemperaturegasto
Rejected
ahightemperatureliquidbytransferringheat
toalowertemperaturemedium,usually
3
ambientair
Hot Refrigerant Vapor
Condenser
Simplified
Cool
can
Gas inside
changes
phases
from vapor
to liquid
Heat
Compressor
Evaporator
Evaporator
Cold Refrigerant Vapor
Load
Heat
VaporCompressionCycle
Cooling
Tower
Step4:Thehightemperature
liquidthenentersthe
expansiondeviceallowinga
portionoftherefrigerantto
entertheevaporator
Rejected
3
Hot Refrigerant Vapor
Condenser
Simplified
Spray
can for
cooling
effect
Heat
Engine
Motor
Turbine
Compressor
Evaporator
Evaporator
Cold Refrigerant Vapor
Load
Heat
CompressorSizeRanges
Scroll <2 RT 10 RT
Reciprocating 20-200 RT
Centrifugal 200 RT +
VaporCompressionDriveOptions
Electricmotor
Constantspeed
VariableSpeedDrive(VSD)
NaturalGasEngine
SteamTurbine
NaturalGasCooling
Equipment
EngineDriven
SteamTurbine
Absorption
HeatPump
EngineDrivenChillerwithHeat
RecoveryOptions
Exhaust Gas /
Heat Recovery
To Load
From Load
Evaporator
Expansion Valve
Compressor
Cooling
Condenser
Cooling
Tower
EngineFuelUseandHeatRecovery
Radiation(3%)
Exhaust
Unrecoverable(16%)
Recoverable
Energy
(48%)
Exhaust(15%)
JacketCoolant33%
ShaftPowertoDrive
ChillerCompressor
33%
EngineChillerManufacturers
AdvantagesofEngineDrivenCooling
Potentiallyloweroperatingcosts
Providesflexibilityofoperationtohelpcontroloverallenergycosts
wheninstalledinconjunctionwithelectricchillersinahybridplant
Variablespeedforefficientpartloadoperation
Engineheatrecoveryfordomestichotwaterandotherthermalenergy
needs
Capableofprovidingleavingchilledwatertemperaturesbelow42oF
Initialcostsquicklyoffsetbyenergysavingsinareaswithhigh
electricityprices
Environmentallyfriendly
NaturalGasEngineDrivenCooling
Sizing <25tonstoover1000tons
Applications Widerangeofcoolingcapacitiesand
temperaturesmakeenginedrivencoolinganexcellent
choicefor:
Schools
Hospitals
ApartmentBuildings
OfficeBuildings
NursingHomes
Hotels
Retailers
IceRinks
Industrialprocesses
TurbineDriveChillerSystem
Compressor
Steam
Turbine
Wet Steam
Tower Water
Return
Steam
Condenser
Steam Supply
Condensate
Condenser
AbsorptionCooling
Heatdrivessystem
Oftenbestchoicewhen:
Electricdemandchargesare
high
Electricityuseratesarehigh
Summertimenatural
gaspricesarefavorable
Limitedelectricserviceavailable
RecoveredHeatisavailable
AbsorptionSystemComponents
Consistsoffourmajorelements
Generator
Condenser
Evaporator
Absorber
40
BasicAbsorptionChillerCycle
Tower
Water
Tower
Water
Pump
Chiller System
Generator
Pump
Absorber
Expansion Valve
Chilled Water
Supply
ColdAir
Chiller Heat Exchanger
Cooling
Tower
Air Handler
Warm Water
Return
Chilled
Water
Pump
NaturalGasAbsorptionCooling
Sizing severaltonstoover1000tons
Types
Heatrecovery e.g.,CHPsystem
Hybridsystems
Chiller
Chiller/heater
Singleordoubleeffectsystems
Direct&IndirectFired
AirCooled&WaterCooled
Absorptionheatpumps
AdvantagesofAbsorptionCooling
Heatandcoolwiththesameunit
Usuallyloweroperatingcosts
Safe,quietanddependableoperation
Reliable,lowmaintenance
Directfiredabsorberhasasmallerfootprintthan
anelectricchillerwithboiler
Initialcostsoffsetbyenergysavings
AbsorptionManufacturers
Broad
(100-1100 Tons)
Carrier (100-1500
Tons, aka Sanyo)
Thermax
(10-1400 Tons)
Trane
(380-500 Tons)
Yazaki
(10-200 Tons)
Robur
(5 Tons)
York
(120-13500 Tons)
EngineDriven
Heatpumps
Similartoelectricheatpumps
Electricmotorreplacedwitha
naturalgasdrivenengine
Excellentpartloadefficiencies
Multiplezonecapable
Heatingefficiencyequivalentto
160%
GasHeatPump
LowTemperaturePerformance
120%
%Capacity
100%
80%
SanyoGasVRF
60%
40%
ElectricHeatPump
20%
0%
50
40
30
20
10
AmbientTemperature DegF
10
20
GasHeatPumpManufacturers
8,11&15Tonunitsavailable
DuctedorDuctlessOptions
DuctlessUnitsidealforZoning
Aircooledcondensingin
packagedunit
CoolingCOPof1.4
HeatingCOPof1.6
EngineDrivenHeatPumps
16&24Tons
VariableRefrigerantFlow
SimultaneousHeatingandCooling
Somemodelsalsogenerateelectricity
Noemergencyheatneededwhenverycold
Upto120m(393ft)ofpipingbetweenthe
outdoorunitandthewaterheatexchanger
NaturalGasCooling
Economics
CoolingwithNaturalGasCostsLess
20YearLifeCycleCostAnalysis
20YrLifeCycleCost($mil)
3.0
2.4
Annual
EnergyCost
2.5
2.0
Average
Maintenance
1.5
1.4
1.2
InstalledCost
0.9
1.5
0.6
1.0
Simple
Payback
Internal
Rateof
Return
Absorption SingleEffect/
usingWasteHeat
4.17
8.1%
EngineDrivenw/Heat
Recovery
5.67
6.9%
ComparedtoElectric
CentrifugalChiller
0.5
0.0
Electric
Absorption Absorption Absorption
Centrifugal
Single
SingleEff Double
Effect
/using
Effect
DirectFired WasteHeat
Engine
Driven
Chiller
Engine
Drivenw/
Heat
Recovery
NaturalGasCooling
Emissions
NaturalGasCoolingisCleaner
TonsCO2perYear
ChillerAnnualGHGEmissions
300
263
237
240
200
108
100
0
Electric
AbsorptionSingle
CentrifugalChiller EffectChillerusing
WasteHeat
GasEngineChiller
GasEngineChiller
wHeatRecovery
GasAirConditioningWebsite
GeneralGasCoolingandHumidityControlInformation
Videos
CaseStudies
Tools
Studies
Allmajorcategoriesofgascoolingarediscussedonthe
EnergySolutionCentersGasFiredAirConditioning
Equipmentsiteathttp://www.gasairconditioning.com
WhyChooseNaturalGasCooling?
Reducesenergycosts
Reduceselectricdemandcharges
Goodfortheenvironment
Reliable,plentifulenergysource
Optionstosuitvirtuallyanyapplication
Avoidelectricsystemupgradechargeswhenaddingnew
coolingequipment
Smallerstandbygeneratorrequirementsforemergency
cooling
Questions?
Appendix
Manufacturers
EngineDrivenEquipment
Manufacturers
TECOCHILLPackagedChillers
25 400Tons(Chillers/DX)
Automotive/IndustrialEngines
ManufacturedinUSA
HCFC(R22)andHFC(R134a)
Screw&ReciprocatingCompressors
Water&AirCooledCondensing
ETL/MEAListed
EngineDrivenEquipment
Manufacturers
TRANE Gas Powered
CenTraVac (GPC)
Chiller Package
1653,000Tons
WaukeshaEnginator
ManufacturedinUSA
HCFC123
CentrifugalCompressor
OptionsonCondensing
EngineDrivenEquipment
Manufacturers
YORKYB&YGChillers
4002,100Tons(Chillers)
IndustrialEngines
ManufacturedinUSA
HFC(134a)
CentrifugalCompressors
SteamTurbineChiller
YorkInternational
Sizes700to2800Tons
Usestraditionalvaporcompression
refrigerationcycle
Backpressureorcondensingturbineoption
1.8CoefficientofPerformance(COP)
ProvidesopportunitytoIntegratewaste
steamfromCogeneration
AbsorptionEquipmentManufacturers
BROADUSA
DirectFiredChillerHeater
100 1,100Tons
NOCFCs
Standard&HighEfficiency
Models
AbsorptionEquipmentManufacturers
CarrierChiller/Heater
Direct&SteamFired
100 1,500Tons
PrivateLabeled Japan
InternationalServiceProgram
AbsorptionEquipmentManufacturers
Absorption15 150tons
HeatPumps(absorptionbased)
Customsystemsto15,000tons
Simultaneousheatandcooling,orrefrigeration
Coproducehotwater,
Airorwatercooled,(ammoniawater)
AbsorptionEquipmentManufacturers
DirectFiredChillers&HeatPumps
4tonunitspackagedto25tons
Ammoniawatersystem
Lowtempunitsavailable
ManufacturedinUSA
Aircooledsystems
Singlephasepower
AbsorptionEquipmentManufacturers
Thermax Chiller/Heater
Direct,HotWater&SteamFired
10 1,400Tons
ProducedinIndia
InternationalSales&ServicePrograms
AbsorptionEquipmentManufacturers
TRANE HORIZON Series
DirectFiredChillerHeater
380 500Tons
ManufacturedinUSA
DoubleEffectOnly
ULListed
AbsorptionEquipmentManufacturers
Yazaki AbsorptionChillers
DirectFiredSingle&DoubleEffectUnits
3 200Tons
ManufacturedinJapan
WaterCooledCondensing
AbsorptionEquipmentManufacturers
SingleEffect,DoubleEffect
andDirectFiredChillers
120 1,350Tons
ManufacturedinUSA
HeatRecoveryUnitsAvailable
SteamUnitsAvailable
8and15TonOutdoorUnits
AddedDiversity
w/ExtraAirHandlers
VarietyofAirHandlersavailable
tosuitneedsofeachzone.
Upto17zoneswith8TonUnit
Upto33zoneswith15TonUnit
11TonRooftopUnit