Anda di halaman 1dari 16

Detail Summary Scope Automation SLS-1

Item Description

Jenis
M/L

Type

Automation System at Reception Area


1.2 Transfer Carriage Control System at Dry End
1.2.1 Panel c/w PLC +Mimic Diagram

Qty

2
1
1

Lot
Lot
Set

Lot

Lot

Lot

Frequency Inverter
Proximity Switches
Proximity Switches
- Hydraulic pipes - Hydraulic fittings - Pipe Clamp
and Accessories - Hydraulic hoses - Hose joints Manpower - Hydraulic Tools
- Indexer Frame - Convertible Indexer Pusher & Puller
- Manpower for Design and Modification - M.Steel
Material - Manpower for cutting and welding work Consumables
- Hydraulic Solenoid Valve - Hydraulic Cylinder Hydraulic Fitting & Accessories - Manpower Hydraulic Tools
- Hydraulic Pump - Hydraulic Fitting & Accessories Manpower - Hydraulic Tools

2
6
4

Unit
Unit
Unit

Lot

Lot

Lot

Lot

- Engineering and manpower for design ,wiring and


testing - Selector Switch - Relays - Terminal Block Tools & Accessories
Control Cable

Lot

Lot

Lot

Lot

Cutting & Welding


Tools
Tester and Tools - Debugging
Software

L
L

Manpower
Manpower

1
1

Lot
Lot

Lot

-Butterfly Valve
(Metal Seat)
-P. Actuator
-I/P Positioner
-Solenoid Valve
-Pneumatic Fitting & Accessories
-Adaptor and Bracket
-Manpower to install, calibration & testing

Set

-Ball Valve

Unit

Console Panel c/w Mimic Diagram


M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
Ethernet module
Accessories

M
M
M
M
M
M
M
M
M
L

Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing

1.2.2 Instrumentation for Transfer Carriage Control System


Inverter for Hydraulic Power Pack
Positional Sensor
Positional Switches
1.2.3 Modification existing Hydraulic Piping Transfer Carriage

Mechanical Modification on Transfer Carriage for the installation of


new hydraulic Indexer System .

M
M
M
M

M/L

1.2.4 To modify the existing Hydraulic Power Pack with additional heavy
duty cylinder and solenoid valve of Transfer Carriage No. 1 and No.2
1.2.5 To add new Hydraulic pump for Indexer System . To be installed in
the existing Hydraulic Power Pack 5.5 KW
1.2.4 Modification existing operational panel of transfer carriage (Interface
with the new control panel)
1.2.5 Electrical Wiring Work (Conduit, Cable Tray and Cable)
(Power and Control Only)
1.2.6 Instrument & Equipment Installation
1.2.7 System Installation including Wiring Check, Signal Check, and Field
Debugging on Software and linking system back to SCADA system
1.2.8 Engineering & Programming
1.2.9 Testing, Commisioning dan site training
Automation System at Sterilizer Station

M/L
M
M/L
M/L

Conduits - Cable Tray - Flexible Conduit Manpower


M.Steel Material -

Manpower -

Manpower -

2.1 Steam Management System for Existing Horizontal Sterilizer Control System (
by upgrading the existing manual system to Intelligent Control System )
2.1.1 Modification existing 6" High Performance Butterfly Control Valve

M
M
M
M
M
M
M
L

2.1.2 New dia.2" ( 50mm ) Stainless Steel Ball Control Valve for Auxiliary
Condensate Drain

Unit

M
M
M
M
L

-P. Actuator
-Solenoid Valve
-Pneumatic Fitting & Accessories
-Manpower to install, calibration & testing

L
2.1.3 Steam Management Control Panel c/w PLC and Colour Touch
Screen , Power Protection System and Manual Operation for all Control Valve
for Four ( 4 ) Horizontal Sterilizers ( Intelligent Version )

M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
L
2.1.4 To modify the existing control valve manual operation Panel to
interface the Steam Management Control Panel

M/L

2.1.5 System Installation including Air Tubing and Fittings ,Signal Check
,Field Debugging on Software , and linking system to SCADA system in CCR

M/L

2.1.6 RTD Temperature Sensors for four ( 4 ) Sterilizers


Pressure Transmitter for each Sterilizer
Proximity Switches for Sterilizer Doors
2.1.7 Installation of Field Instrumentation and Control Valves
2.1.8 Supply and Installation of air compressor complete with G.I piping
work
2.1.9 Electrical Wiring including Conduits, Cable Tray and Cables ( Control
Only )
2.1.10 Engineering and Programming
2.1.11 Testing , Commissioning and Site Training
2.2 Back Pressure Receiver (BPR) Control System ( by upgrading the existing control

Console Panel c/w Mimic Diagram

Unit

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
HMI Touch Screen 7"

Unit

Lot

Lot

Unit

4
8
1

Unit
Unit
Lot

Lot

Lot

1
1
1

Lot
Lot
Lot

Lot

Unit

1
1
1
1

Lot
Unit
Unit
Unit

1
1

Lot
Lot

Lot

Manpower

Lot

Manpower
Manpower

1
1

Lot
Lot

M
PLC Set Consist :

Accessories
Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing
- Engineering and manpower for design ,wiring and
testing - Selector Switch - Relays - Terminal Block Tools & Accessories
- Manpower - Tester and Tools - Debugging
Software
RTD Sensor

M
M
M
M
M/L

Converter

M/L
M/L

L
L

M.Steel Material -

Manpower -

Cutting & Welding


Tools
- Air Compressor - GI Piping Work - Pneumatic
Fitting - Nylon Tubing
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
Manpower
Manpower

system to Intelligent Version )

2.2.1 PLC + Mimic Diagram

2.2.2 - 3" dia High Pressure Control Valve c/w I/P Positioner (Modulating
type)
if existing lakukan re-condition)
2.2.4 Instrumentation
Pressure Transmitter (Signal Splitter)/re-condition
Pressure Transmitter boiler header/re-condition
RTD Temperature/re-condition
2.2.5 Air Piping Work for Pneumatic System
2.2.6 Installation of Field Instrumentation and Control Valves
2.2.7 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
2.2.8 Inter-Connecting Piping System complete with Strainers, Isolating and
By-Pass Valves Engineering and Programming
2.2.9 Testing, Commissioning and Site Training
2.2.10 Engineering and Programming

M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay
Globe Valve

M
M
L

I/P Positioner
Manpower-Calibration

M
M
M
M
L
M/L

RTD Sensor
Converter
-

M.Steel Material -

M/L

Manpower -

Manpower -

Cutting & Welding


Tools
Tester and Tools - Debugging
Software

L
L
L

Automation System at Threshing Station & Pressing Station ( 2-Line )


3.1 AutoFeeder Control System
3.1.1 PLC ( Programmable Logic Controller )

Lot

14
3
3
1
16

Unit
Unit
Unit
Lot
Unit

Cable Tray - Flexible


Conduit - Manpower

Lot

Manpower

Lot

3.1.3 Testing, Commissioning, Site Training, Full manual Book, All Datasheet component & Indonesian
L
supplier data Doc.
Manpower
3.2 Digester Level and Temperature Control System
3.2.1 PLC ( Programmable Logic Controller )
M
PLC Set Consist :
M
BackLane Rack (Modular) System
M
Power Supply
M
CPU Module
M
D/I Module
M
D/O Module
M
A/0 Module
M
A/I Module
M
Ethernet module
M
Accessories
M
Selector Switches
M
Push Button
M
Relays & Contact
M
MCB & CB
M
Sirene & R. Light
M
Terminal Block
M
Cable Control
M
24 VDC Power Supply
M
Pilot Light
Engineering and Manpower for design, Wiring and
L
Testing
Inverter For Elevator Fruit Conv 5.5 KW
M
Inverter 5.5 KW
Distributing Conv 5.5KW
M/L
modification
Top Cross Conv 5.5 KW
M/L
modification
Recycle Conv 4KW
M/L
modification

1
1 lot
1

Lot

Lot

3
2
2
2

Unit
Unit
Unit
Unit

8
8
8

Unit
Unit
Unit

Unit

Unit

2
16

Unit
Unit

Lot

Lot

Lot

Lot

Lot

Debugging
Software

Lot

Manpower

Lot

3.1.2 Field Instrumentation and Equipment - Positioner Sensor for Autofeeder


Load sensor
Inverter 2.2KW
Level Sensor
3.1.3 Installation of Field Instrumentation and Equipment
3.1.4 Modification of Starter Panels for Autofeeder, Threshing

M
M
M
L
M/L

3.1.5 Electrical Wiring Work (Incl Cable Tray Hot Dip Galvanized, Conduit, Cable)

M/L

3.1.3 System Installation including Wiring Check, Signal Check, Field Debugging on
Software and Linking System to SCADA System in CCR

M/L

3.2.2 Field Instrumentation and Equipment


Level Sensor
Sliding Feeding Door Digester Motorized 220Watt
Temperature Sensor
6" Virgin Oil Valve (Step Control Type-ON/OFF)

2" Steam Control Valves (Step Control Type)

Limit Switches for Recycle Conv


3.2.3 To provide Run/Stop/Trip load free contact inside Starter Panels for Digesters and
Screw Presses

M
M/L

3.2.6 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

3.2.7 Air Piping Work for Pneumatic System

M/L

3.2.9 Testing, Commissioning, Site Training, Full manual Book, All Datasheet component
& Indonesian supplier data Doc.

Control cable -

Accessories consist of the following :- - Selector


switches - Push buttons - Relays & Contact - MCB
& CB - Terminal block - Auto cables - 24VDC PSU Pilot Lights
Incl
-

M.Steel Material -

Cutting & Welding


Tools
- Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- GI Piping Work - Pneumatic Fitting - Nylon Tubing
-

M/L
L

Conduits -

Motorized + Modification Sliding door


RTD Sensor
Converter
Dia 2" SS Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner
Dia 2" SS Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner
Limit Switches + Modification plate
Control Panel

3.2.5 Installation of Field Instrumentation and Equipment

3.2.8 System Installation including Wiring Check, Signal Check, Field Debugging on
Software and Linking System to SCADA System in CCR

M
M
M
M
M
M
M
M
M
M
M
M
M
M

3.2.4 Control Panel c/w Manual Operation Station and Indicator Lights

PLC
Relay + MCB
Timer

M
M
M

Manpower -

Manpower -

Tester and Tools -

Lot

3.3 Screw Press (Pressure and Load) Control Interlocking System and Speed Control
System
3.3.1 PLC ( Programmable Logic Controller )

M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M

3.3.3 Modification of existing Power Pack of ( P10 ) Screw Presses. It includes


installation of Cone Pressure Regulating Control Valve
3.3.4 30 KW Inverter for ( P10 ) Screw Presses
45 KW Inverter for (P20) Screw Press
3.3.5 Engineering and Programming

Lot

17
8
8
8
4

Unit
Unit
Unit
Unit
Lot

Existing Assumed_Project New Panel


Existing Assumed_Project New Panel
Manpower
M.Steel Material - Manpower - Cutting & Welding
Tools
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- Manpower - Tester and Tools - Debugging
Software

4
4
1
1

Unit
Unit
Lot
Lot

Lot

Lot

Manpower

Lot

Lot

Load Sensor
Yokogawa Mag. flowmeter
UNICOM High Performance Ball Valve, additional
Strainer c/w Double Acting Actuator and I/P Positioner

9
2
2

Unit
Unit
Unit

Viscosity Sensor
Cutting & Welding
Tools

2
2

Unit
Lots

Accessories
Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing
Timer

Hydraulic Regulating Control Valve


Control Card

L
M
M
L
M/L

3.3.7 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

3.3.8 System Installation including Wiring Check, Signal Check, Field Debugging
on Software and Linking System to SCADA System in CCR

M/L

3.4 Crude Oil Dilution Control System


PLC (Programmable Logic Controller)

1
BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module

M
M
M
M
M
M

3.3.6 Installation of Field Instrumentation and Equipment

3.3.9 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.

Lot

PLC Set Consist :

L
3.3.2 Field Instrumentation and Equipment
Load sensor
Pressure Sensor
Cone Pressure Regulating Control Valve
Cone Pressure Control Card

M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Accessories
Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing

Instrumentation for One Unit of Crude Oil Dilution Control System


Load Sensor
Dia.2 Magnetic Flowmeter for Hot Water

M
M

Dia.2 Hot Water Control Valve c/w Double Acting Actuator and I/P Positioner

Viscosity Sensor
Installation of Field Instrumentation and Equipment

M/L

M.Steel Material -

Manpower -

Modification of Starter Panels for Digester and Screw Press

M/L

Electrical Wiring Work including Conduits, Cable Tray and Cables ( Power and
Control Only )

M/L

System Installation including Wiring Check, Signal Check, Field Debugging on


Software and Linking System to SCADA System in CCR

M/L

Testing, Commissioning, Site Training, Full manual Book, All Datasheet component
& Indonesian supplier data Doc.
Automation at Depericarping Station
4.1 Depericarper Control System
4.1.1 Programmable Logic Controller ( PLC )

Engineering and manpower for design ,wiring and


testing - Relays - Terminal Block - Tools &
Accessories
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- Manpower - Tester and Tools - Debugging
Software

M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M

4.1.4 Installation of Field Instrumentation and Equipment . It include simple


modification on polishing drum

M/L

4.1.5 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

4.1.6 Air Piping Work for Pneumatic System

M/L

Automation at Clarification Station


5.1 Process Monitoring And Control System
Ex-Vibrating Crude Oil Tank Temperature And Level Control System
5.1.1 PLC ( Programmable Logic Controller )

5.1.2 Field Instrumentation and Equipment for :RTD Temperature Sensor


Dia 2" Steam Control Valve c/w Double Acting Actuator & Solenoid Valve (step
control type)

Lot

1
1

Lot
Lot

6
2
2
2

Unit
Unit
Unit
Unit

16

Unit

Lot

Lot

Nylon Tubing

Lot

Manpower

Lot

Debugging
Software

Lot

Manpower

Lot

1
1

Lot

Lot

1
1

Lot
Unit

Unit

Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing
Relay+MCB
Timer
Load Sensor
Flow Sensor
Damper
-

M/L

4.1.9 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.

Lot

Accessories

M
M
M
M

4.1.3 Modification of Starter Panels for Fibre Cyclone Fan, CBC dan Airlock
Fibrecyclone

4.1.8 System Installation including Wiring Check, Signal Check, Field Debugging
on Software and Linking System to SCADA System in CCR

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module

4.1.7 Engineering and Programming

Lots

PLC Set Consist :

M
M
4.1.2 Field Instrumentation and Equipment
Load Sensor
Air Flow Sensor c/w Special Mounting
Servo Damper
Nut Polishing Drum Choking Detection Sensor

Manpower

16 Units

Engineering and manpower for design ,wiring and


testing - Relays - Terminal Block - Tools &
Accessories
M.Steel Material - Manpower - Cutting & Welding
Tools
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower

GI Piping Work -

Pneumatic Fitting -

L
M/L

Manpower -

M
M
M
M
M
M
M
M
M
M
M

Tester and Tools -

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer

M
M

RTD Sensor
Converter

Dia 2" SS Ball Valve

M
M
M

P. Actuator
Solenoid Valve
Valve Positioner

5.1.4 Level Control System


Level Sensor

1
1

Lot
Unit

11 KW Inverter inside MCC Panel for CPO Pump control to CCT

Unit

5.1.5 Engineering and Programming


5.1.6 System Installation including Wiring Check, Signal Check, Field Debugging
on Software and Linking System to SCADA System in CCR
5.1.7 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
Continuous Clarifier Tank No.1 , No.2 and No.3 Monitoring and Control System
5.1.8 PLC ( Programmable Logic Controller )

5.1.9 Field Instrumentation and Equipment for :5.1.10 Temperature Control System
RTD temperature sensor for each Tank
Dia 2" steam control valve for each Tank temperature Control Close Coil

5.1.11 Auto Drain Control System - Dia.6" SS Ball control valve for each Tank - 3
units

5.1.12 System Installation including Wiring Check, Signal Check, Field


Debugging on Software and Linking System to SCADA System in CCR
5.1.13 Engineering and Programming
5.1.14 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
Wet Oil Tank No.1 & No.2 And Dilution Hot Water Tank Monitoring and Control
System
5.1.15 PLC ( Programmable Logic Controller )

5.1.16 Field Instrumentation and Equipment for :5.1.17 Temperature Control System RTD temperature sensor
Dia 2" steam control valve ( step control type )

Manpower

Lot

Debugging
Software

Lot

Manpower

Lot

1
1

Lot
Lot

1
1
3

Lot
Lot
Unit

Unit

Lot

Debugging
Software

Lot

Manpower

Lot

Manpower

Lot

Lot

Lot

1
1
1

Lot
Lot
Unit

Unit

M/L

Manpower -

Tester and Tools -

M
M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer

M
M

RTD Sensor
Converter

Ball Valve

M
M
M

P. Actuator
Solenoid Valve
Valve Positioner

Dia 6" SS Ball Control Valve

M
M

P. Actuator
Solenoid Valve

M/L

M
M
M
M
M
M
M
M
M
M
M

Manpower -

Tester and Tools -

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer

M
M
M
M
M
M

RTD Sensor
Converter
Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner

5.1.18 Level Monitoring System - Level Sensor


5.1.19 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
5.1.20 Engineering and Programming
5.1.21 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.

Unit

Debugging
Software

Lot

Manpower

Lot

Manpower

Lot

Lot

Lot

M/L

Manpower -

Tester and Tools -

Sludge Tank and Sludge Buffer Tank Monitoring and Control System
5.1.22 PLC ( Programmable Logic Controller )

M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply

M
M
M
M
M
M
M
M
5.1.23 Field Instrumentation and Equipment for :5.1.24 Temperature Control System RTD temperature sensor

Dia 2" steam control valve ( step control type )

CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer
1
1
2

Lot
Lot
Unit

Unit

Unit

Unit

Debugging
Software

Lot

Manpower

Lot

Manpower

Lot

1
1

Lot
Lot

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer
Pressure Sensor

Unit

P. Actuator

Unit

M
M

Solenoid Valve
Valve Positioner

P. Actuator

Unit

M
M
M

Solenoid Valve
Valve Positioner
Operation Panel
Accessories consist of the following :- - Selector
switches - Push buttons - Relays & Contact - MCB
& CB - Terminal block - Auto cables - 24VDC PSU Pilot Lights

Lot

Debugging
Software

Lot

Manpower

Lot

Manpower

Lot

Lot

Lot

M
M

RTD Sensor
Converter

M
M
M
M

Dia 2" SS Ball Valve


P. Actuator
Solenoid Valve
Valve Positioner

5.1.25 Level Monitoring System - Level Sensor for Sludge Tank only
Auto Drain Control System for Brush Strainer Dia 2" Auto Drain Control Valve

5.1.27 System Installation including Wiring Check, Signal Check, Field


Debugging on Software and Linking System to SCADA System in CCR
5.1.28 Engineering and Programming
5.1.29 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
Sludge Centrifuge Separator Optimization Control System
5.1.30 PLC ( Programmable Logic Controller )

5.1.32 Pressure Sensor at Sludge Inlet Point to Separator


5.1.33 Dia.4 inch Step Control Valve for Sludge Feeding ( Modify the existing
Manual Ball Valve with pneumatic actuator and manual override lever )

5.1.34 Dia.2 inch Control Valve c/w Feedback System for Hot Water Feeding (
Modify the existing Manual Ball Valve with pneumatic actuator and manual override
lever )

5.1.35 Remote Operation Panel

M
M
M
M/L

M
M
M
M
M
M
M
M
M
M
M
M

M/L
5.1.36 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
5.1.37 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
5.1.38 Engineering and Programming

M/L

Dia 2" SS Ball Valve


P. Actuator
Solenoid Valve
-

Manpower -

Tester and Tools -

PLC Set Consist :

Engineering and manpower for design ,wiring and testing


-

Manpower -

Tester and Tools -

Remaining Tanks Temperature and Level Monitoring And Control System


5.1.39 PLC ( Programmable Logic Controller )

M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module

M
M

Relay+MCB
Timer

M
M

Valve Positioner

M
M
M

RTD Sensor
Converter

5.1.43 Level Monitoring and Temperature Control System for Reclaim Oil Tank

Ball Valve

RTD temperature sensor - 1 unit

M
M
M

P. Actuator
Solenoid Valve
Valve Positioner

M
M
M

RTD Sensor
Converter

Ball Valve

M
M
M
M

5.1.40 Field Instrumentation and Equipment :5.1.41 Temperature Monitoring System


RTD temperature sensor for Hot Well Tank - 1 unit
Dia 2" steam control valve ( step control type ) - 1 unit

Dia 2" steam control valve ( step control type ) - 1 unit

Level Sensor - 1 unit


5.1.48 Level Monitoring and Temperature Control System for Process Hot Water
Tank
RTD temperature sensor - 1 unit
Dia 2" steam control valve ( step control type ) - 1 unit

Level Sensor
Overflow Sensor for Process Hot Water Tank
Valve Water 2" (*perlu klarifikasi diameternya)

M
M
M
M

*karena air ada kiriman dari Hot well tank -vacuum untuk penghematan air

1
1

Unit
Unit

Unit

Unit

Unit

Unit

Unit

P. Actuator
Solenoid Valve
Valve Positioner
Overflow Switch

1
1

Unit
Unit

Butterfly Valve

2
1
1
1

Unit
Lot
Lot
Unit

Lot

Lot

Lot

Lot

P.Actuator
Solenoid Valve
Valve Positioner
Manpower

5.1.53 Monitoring System for Vacuum dryer ( 2 units )


Vacuum Sensor for Vacuum oil Dryer
5.1.55 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
5.1.56 Engineering and Programming
5.1.57 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
5.2 Oil Skimmer ( Oil Thickness ) Control System for Continuous Clarifier Tanks
5.2.1 PLC ( Programmable Logic Controller )

M
M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/0 Module
A/I Module
Ethernet module
Relay+MCB
Timer

5.2.2 Oil Layer ( Thickness ) Control System for three ( 3 ) Continuous Clarifier Tanks
Oil Layer Sensor - 1 set/ lot
Oil Surface Level Sensor - 1 unit/lot
Motorized Geardrive for Oil Skimmer - 1 unit/lot
5.2.7 To supply and install Side Glass Chamber for viewing oil thickness for each
Clarifier Tank

5.2.8 Installation of Field Instrumentation

M/L

5.2.9 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

5.2.10 System Installation including Wiring Check, Signal Check, Field Debugging on
Software and Linking System to SCADA System in CCR

M/L

5.2.11 Engineering and Programming Testing, Commissioning, Site Training, Full manual
Book, All Datasheet component & Indonesian supplier data Doc.
5.3 Production Oil Monitoring System
5.2.1 PLC ( Programmable Logic Controller )

Oil layer Sensor


Level Sensor
Motorized
Side Glass

M
M
M

M.Steel Material -

Manpower -

1 Sets
1 Unit
1 Unit
3
Lot

Cutting & Welding


Tools
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- Manpower - Tester and Tools - Debugging
Software

Lot

Lot

Lot

Manpower

Lot

Lot

M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module

M
M
M
M
M
M
5.3.2 Field Instrumentation and Equipment for :- 1.2.1 Production Oil Measurement
System - Dia. 2" ( 50mm ) Yokogawa Coriolis Mass Flowmeter
5.3.3 Installation of Field Instrumentation

5.3.5 System Installation including Wiring Check, Signal Check, Field Debugging on
Software and Linking System to SCADA System in CCR

M/L

6.1.3 Installation of Field Instrumentation and Equipment


- Nut Hopper Level Monitoring System
6.1.4 PLC ( Programmable Logic Controller )

6.1.5 Field Instrumentation and Equipment ( 2-Line )


Level Sensor for Nut Hopper
Sliding gate Motorized 200 Watt
Control Vibrating Feeder to Ripplemill
Load Sensor
6.1.6 Installation of Field Instrumentation and Equipment
LTDS -1 & LTDS-2 Control System
6.1.7 PLC ( Programmable Logic Controller )

6.1.7 Field Instrumentation and Equipment for LTDS -1 System(2-Line )


- Servo Damper for LTDS-1 Fan
- Load Sensor for LTDS-1 Fan
- Vacuum Sensor for LTDS-1 Column
6.1.8 Field Instrumentation and Equipment for LTDS -2 System(2-Line )
- Servo Damper for LTDS-2 Fan
- Load Sensor for LTDS-2 Fan
- Vacuum Sensor for LTDS-2 Column
6.1.9 Installation of Field Instrumentation and Equipment
- Hydro-Cyclone Monitoring System

Control cable -

M
M/L

6.1.2 Field Instrument and Equipment


Servo Damper for De-Stoner Fan
Load Sensor for De-Stoner Fan
Vacuum Sensor for De-Stoner Column

M.Steel Material -

Manpower -

Lot

Coriolis mass Flow Meter


Conduits - Cable Tray - Flexible
Conduit - Manpower
Manpower - Tester and Tools - Debugging
Software

1
1

Lot
Lot

Lot

Manpower
Manpower

1
1

Lot
Lot

Lot

Lot

1
5
1
1

unit
Unit
Unit
Lot

1
1

Lot
Lot

6
6
6
16
1

Unit
Unit
Unit
Unit
Lot

1
1

Lot
Lot

M/L

5.3.4 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

5.3.6 Engineering and Programming


5.3.7 Testing, Commissioning, Site Training, Full manual Book, All Datasheet component
& Indonesian supplier data Doc.
Automation System at Kernel Recovery Station
6.1 Process Monitoring and Control System
- De-stoner Control System
6.1.1 PLC ( Programmable Logic Controller )

L
L

M
M
M
M
M
M
M
M
M
M
M
M
M
M/L
M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer
Motorized
Load Sensor
Vacuum Sensor
- M.Steel Material Tools

M
M
M
M
M
M
M
M
M
M

Manpower -

Cutting & Welding

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer

M
M
M/L
M
M/L

D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer
Cutting & Welding
Tools

Level Sensor
Motorized
Electro Potensio/Serial integration
Load Sensor
M.Steel Material - Manpower - Cutting & Welding
Tools

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer

M
M
M

Motorized Damper
Load Sensor
Vacuum Sensor

2
8
2

Unit
Unit
Unit

M
M
M

Motorized Damper
Load Sensor
Vacuum Sensor
- M.Steel Material Tools

Unit

2
1

Unit
Lot

M/L

Manpower -

Cutting & Welding

6.1.10 PLC ( Programmable Logic Controller )

M
M
M
M
M
M
M
M
M
M

6.1.11 Field Instrumentation and Equipment ( 2-Line )


Load Sensor for Stage 1 ,Stage 2 and Stage 3 - 3 units Pumps ( Line 1 )

Load Sensor for Stage 1 ,Stage 2 and Stage 3 - 3 units Pumps ( Line 2 )

Pressure Sensor (if Inverter HydroCyclone Existing) *


Inverter 22 KW Hydrocyclone *
6.1.12 Installation of Field Instrumentation and Equipment
6.1.13 Electrical Wiring including Conduits, Cable Tray and Cables (
Control Only )
6.1.14 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
6.1.15 Engineering and Programming
6.1.16 Testing, Commissioning, Site Training, Full manual Book, All
Datasheet component & Indonesian supplier data Doc.

M
M
M/L
M/L
M/L

L
L

PLC Set Consist :

Existing
- M.Steel Material - Manpower - Cutting & Welding
Tools
- Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- Manpower - Tester and Tools - Debugging
Software
Manpower
Manpower

6.2 Temperature Control System for Horizontal Kernel Dryer/Silo


6.2.1 PLC ( Programmable Logic Controller )

6.2.2 - RTD Temperature Sensor ( Top Hot Air Duct ) - 3 units

M
M
M
M
M
M
M
M
M
M

PLC Set Consist :

M
M

6.2.3 - Dia.3" Steam C. Valve ( step control type ) - 3 units

M
M
M
M

6.2.4 - RTD Temperature Sensor ( Bottom Hot Air - 3 units Duct )


6.2.5 - Dia.3" Steam C. Valve ( step control type ) - 3 units

- Load Sensor
Level Sensor for Nut Hopper *Nut/Kernel Drier Silo
Motorized for Sliding Gate at Kernel Inlet Chute *
6.2.7 Installation of Field Instrumentation and Equipment

M
M
M
M
M
M
M
M
M
M/L

6.2.8 Electrical Wiring including Conduits, Cable Tray and Cables ( Control
Only )

M/L

6.2.9 System Installation including Wiring Check, Signal Check, Field


Debugging on Software and Linking System to SCADA System in CCR

M/L

6.2.10 Engineering and Programming


6.2.11 Testing ,Commissioning and Site Training
Automation System at Fuel Station
7.1 Fibre Storage and Feeding Conveyor Control System ( Moving Floor System )
7.1.1 PLC ( Programmable Logic Controller )

Lot

13

Unit

2
2
1

Unit
Unit
Lot

Lot

Lot

1
1

Lot
Lot

Lot

Lot

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer
RTD Sensor

Unit

Converter
Ball Valve

Unit

P. Actuator
Solenoid Valve
Valve Positioner
RTD Sensor

Unit

Converter
Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner
Load Sensor
Level Sensor
Motorized Cylinder
M.Steel Material - Manpower - Cutting & Welding
Tools
Control cable - Conduits - Cable Tray - Flexible
Conduit - Manpower
- Manpower - Tester and Tools - Debugging
Software

Unit

14
3
3
1

Unit
Unit
Unit
Lot

Lot

Lot

Manpower
Manpower

1
1

Lot
Lot

Lot

Lot

L
L

M
M
M
M
M
M
M

1
BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module

M
M
M

Ethernet module
Relay+MCB
Timer

7.1.2 To design fabricate ,supply and install Fully Automatic Moving Floor System
for Fibre 2.1 )
Hydraulic System includes Power Pack with oil cooler and three ( 3 ) hydraulic
cylinders and piping work

Mechanical Work includes Structural Frame complete with puller system for total
dimension of ( 2.0m x 10m x 3 frames )
7.1.3 Civil Work includes floor foundation , cement wall and ground levelling (
Drawing to be provided )
7.1.4 Field Instrumentation and Equipment
Proximity Switches
Load Sensor for Fuel Conveyor no.1 - 2 units and No.2
7.1.5 Installation of Field Instrumentation and Equipment
7.1.6 Leveller c/w Motor 2.2 KW & Civil Work
7.1.7 Motor Starter Hydraulic Power Pack c/w Oil Cooler

M/L

M/L

Hydraulic Power Pack c/w Gear Pump - Solenoid


Valve - Hydraulic Cylinder - Oil Cooler ( 1 unit ) Hydraulic Fitting & Accessories
- Moving Floor Frame (Fix Portion) - Moving Floor
Frame (Move Portion) - Fibre Leveller - Manpower for
Design and Modification - M.Steel Material Manpower for cutting and welding work - Consumables

M
M
M/L
M/L

MCB + Contactor -

Relays+ P. Light Push Button


Control cable - Flexible Conduits - Cable Tray Manpower
Control cable - Flexible Conduits - Cable Tray Manpower
- Manpower - Tester and Tools - Debugging
Software

Lot

Lot

6 Unit
2 Unit
1
Lot
1 Unit
4 Sets
1

Lot

Lot

Lot

Manpower
Manpower

1
1
1

Lot
Lot
Lot

M
PLC Set Consist :
M
BackLane Rack (Modular) System
M
Power Supply
M
CPU Module
M
D/I Module
M
D/O Module
A/I Module
M
M
Ethernet module
M
Relay+MCB
M
Timer
8.1.2 Instrumentation for the System for two ( 2 ) Boilers ( Boiler No.2-Atmindo and No.3-Indomarine )
Steam Temperature Sensor
M
Signal Splitter
Flue Gas Temperature Sensor
M
Signal Splitter
Furnace Temperature Sensor
M
Signal Splitter
8.1.3 Isolators for Instrumentation for two ( 2 ) Boilers
Smoke Density (%)
M
Signal Splitter
Drum Level (%)
M
Signal Splitter
Boiler Pressure (psig)
M
Signal Splitter
Steam Flowmeter (mt/hr)
M
Signal Splitter
Feedwater Flowmeter (mt/hr)
M
Signal Splitter
Power Meter Main Power feeder
M
Power Meter dengan beban max 2.2 MW
8.1.4 Instrumentation and Equipment Installation
L
Manpower

Lot

2
2
2

Unit
Unit
Unit

2
2
2
2
2
1
1

Unit
Unit
Unit
Unit
Unit
Unit
Lot

8.1.5 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

Cable Control, Flexible Conduits, Cable Tray, Manpower

Lot

- Manpower

Lot

M
L

- Tester and Tools


-Debugging Software

Manpower

Lot

1
1

Lot
Lot

7.1.8 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )
7.1.9 Electrical Wiring for Power Supply to Motors and Panels
7.1.10 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
7.1.11 Engineering and Programming
7.1.12 Testing ,Commissioning and Site Training
7.2 Fibre Conveyor No.1 and Fibre ( Inclined ) Conveyor No.2
Monitoring System at Boiler Station
8.1 Boiler Monitoring System
8.1.1 PLC ( Programmable Logic Controller )

8.1.6 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
(Central Control Room)

8.1.7 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
8.2 Thermal Deaerator Monitoring System
8.2.1 PLC ( Programmable Logic Controller )

M/L
M/L
M/L

Panel -

Manpower -

Proximity Switch
Load Sensor
Cutting & Welding Tools

3 Sets

L
L

M/L

M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB

8.2.2 Field Instrumentation And Equipment


8.2.3 Level Sensor for Deaerator
8.2.4 RTD Temperature Sensor for Water Temperature of Deaerator

M
M/L
M

Manpower -

Timer
Cutting & Welding Tools
RTD Sensor

M
M

8.2.5 - Dia.2" Level Water C. Valve ( step control type ) - 1 units

8.2.5 Installation of Instrumentation

M
M
M
M
M
M
M
M/L

8.2.6 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

8.2.5 - Dia.2" Steam C. Valve ( step control type ) - 1 units

8.2.7 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR

Converter
Ball Valve

P. Actuator
Solenoid Valve
Valve Positioner
Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner
- Manpower - Cutting & Welding Tools
Control cable - Flexible Conduits - Cable Tray Manpower
-

M/L

Manpower -

Tester and Tools -

Debugging
Software

8.3 Softened Water ( Feedwater ) Tank Monitoring and Control System


8.2.8 PLC ( Programmable Logic Controller )

M
M
M
M
M
M
M
M
M
M

PLC Set Consist :

1
1

Lot
Lot

Lot

Unit

Unit

Lot

Lot

Lot

Lot

Lot

Unit

Unit

8
1
1
1

Unit
Unit
Lot
Lot

1
1

Lot
Lot

Lot

1
1

Lot
Lot

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer

8.2.9 Field Instrumentation And Equipment for FeedWater Tank


8.2.10 Temperature Control System for Feed Water Tank
RTD temperature sensor
Dia 2" steam control valve - 1 unit ( step control type )

Load Sensor
8.2.11 Level Monitoring System - Level Sensor
8.2.12 Installation of Instrument and Equipment
8.2.13 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only
)
8.2.14 Air Piping Work for Pneumatic System
8.2.15 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
(Central Control Room)
8.2.16 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
Monitoring System at Water Treatment Plant
9.1 Tank Level and Water Quality Monitoring System
9.1.1 PLC ( Programmable Logic Controller )

9.1.1 Field Instrumentation and Equipment for Water StorageTank No.1


Level Sensor for Treated Water Storage Tank

M
M
M
M
M
M
M
M
M/L
M/L

RTD Sensor
Converter
Ball Valve
P. Actuator
Solenoid Valve
Valve Positioner

Level Sensor
- Manpower - Cutting & Welding Tools
Control cable - Flexible Conduits - Cable Tray Manpower

M/L
-

Manpower -

Tester and Tools -

M/L

Debugging
Software

Manpower
L

M
M
M
M
M
M
M
M
M
M
M/L

PLC Set Consist :

BackLane Rack (Modular) System


Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
Ethernet module
Relay+MCB
Timer
Manpower - Cutting & Welding Tools

Level Sensor IR

Unit

Level Sensor IR

Unit

UltraSonic Sensor
Level Float Switch
Cutting & Welding Tools

2
2
1

Unit
Unit
Lot

9.1.1 Field Instrumentation and Equipment for ChemicalConcrete Tanks


Level Sensor for Chemical Concrete Tanks
9.1.1 Field Instrumentation and Equipment for Sediment BasinNo.1 and No.2
Level Sensor for Sediment Basin
Level Switch ( Float Type ) for Sediment Basin
9.1.1 Installation of instrumentation

M
M
M/L

Manpower -

9.1.1 Modification on existing MCC panel for Water Treatment Plant ( Pump
Operation Status )
9.1.1 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )
Engineering and Programming
9.1.1 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
9.1.1 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
9.2 Sand Filter Control System
9.2.1 PLC ( Programmable Logic Controller )

Lot

Cable Tray Manpower


Tester and Tools - Debugging
Software

Lot

Lot

Manpower

Lot

1
1

Lot
Lot

L
M/L

Control cable -

Flexible Conduits -

Manpower -

M/L

M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
Ethernet module
Relay+MCB
Timer

9.2.2 Field Instrumentation And Equipment ( 4 units of Sand Filter )


9.2.2.1 Dia.4" Control Valve for Sand Filter No.1

9.2.2.2 Dia.4" Control Valve for Sand Filter No.2

9.2.2.3 Dia.4" Control Valve for Sand Filter No.3

9.2.2.4 Dia.4" Control Valve for Sand Filter No.4

9.2.3 Pressure Sensor for Inlet and Outlet points of each Sand Filter

M
M
M
M
M
M
M
M
M
M
M
M

Butterfly Valve
P. Actuator
Solenoid Valve
Butterfly Valve
P. Actuator
Solenoid Valve
Butterfly Valve
P. Actuator
Solenoid Valve
Butterfly Valve
P. Actuator
Solenoid Valve

Unit

Unit

Unit

Unit

Pressure Sensor

Unit

- Manpower - Cutting & Welding Tools


Control cable - Flexible Conduits - Cable Tray Manpower
Manpower

Lot

Lot

Lot

Debugging
Software

Lot

Manpower

Lot

1
1

Lot
Lot

Unit

Unit

Unit

Unit

Unit

9.2.4 Installation of instrumentation and control valves

M/L

9.2.5 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only )

M/L

9.2.6 Engineering and Programming


9.2.7 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
9.2.8 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
Automatic Sampling System
10.1 Solid Sampling Control System - 15 points
10.1.1 PLC ( Programmable Logic Controller )

L
M/L

Manpower -

Tester and Tools -

M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
Ethernet module
Relay+MCB
Timer

10.1.2 Field Instrumentation And Equipment ( 15 Solid Sampling System )


Sampling System for Ripplemills

Sampling System for De-Stoner process

M
M
M
M
M
M
M
M
M

Pneumatic Cylinder
Limit Switch
Pneumatic Cylinder
Limit Switch
Pneumatic Cylinder
Limit Switch
Pneumatic Cylinder
Limit Switch
Pneumatic Cylinder

*Klarifikasi SOP ada pengambilan sample di destoner atau tidak

Limit Switch

Sampling System for Hydrocyclone

M
M
M
M

Pneumatic Cylinder
Limit Switch
Pneumatic Cylinder
Limit Switch

Unit

Unit

- GI Piping Work

Lot

Sampling System for LTDS-1 process


Sampling System for LTDS-2 process
Sampling System at Fibre Cyclone

Sampling System for kernel after kernel dryer


10.1.3 Installation of instrumentation and control valves , including air piping and
tubing work

L
M

Pneumatic Fitting -

Nylon Tubing

10.1.4 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only
)

10.1.5 Engineering and Programming


10.1.6 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
10.1.7 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
10.2 Liquid Sampling Control System - 16 points
10.2.1 PLC ( Programmable Logic Controller )

10.2.2 Field Instrumentation And Equipment ( 14 Liquid Sampling System )


Sampling System for Oil Feed WOT

Sampling System for Sludge after Sludge Separator

Sampling System for underflow of Con. Clarifier Tanks

Sampling System for Production Oil

Sampling System for Blowdown Boiler (Atmindo & Indomarine)

10.2.3 Installation of instrumentation and control valves


10.2.4 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only
)
10.2.5 Engineering and Programming
10.2.6 System Installation for above including Signal Check, Field Debugging on
Software and Linking to SCADA System, via LAN Networking System, inside CCR
10.2.7 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.

- Control cable

Lot

- Flexible Conduits
Cable Tray - Manpower
Manpower

Lot

Manpower, Tester, Tools & Debugging Software

Lot

Manpower

Lot

1
1

Lot
Lot

M
M/L
L
M/L

M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
Ethernet module
Relay+MCB
Timer

M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M/L

3/4" Pneumatic 2-Way Cont. Valve


3/4" Pneumatic 3-Way Cont. Valve
P. Actuator
Solenoid Valve
3/4" Pneumatic 2-Way Cont. Valve
3/4" Pneumatic 3-Way Cont. Valve
P. Actuator
Solenoid Valve
3/4" Pneumatic 2-Way Cont. Valve
3/4" Pneumatic 3-Way Cont. Valve
P. Actuator
Solenoid Valve
3/4" Pneumatic 2-Way Cont. Valve
3/4" Pneumatic 3-Way Cont. Valve
P. Actuator
Solenoid Valve
3/4" Pneumatic 2-Way Cont. Valve
3/4" Pneumatic 3-Way Cont. Valve
P. Actuator
Solenoid Valve
Manpower, Cutting & Welding Tools

Unit

Unit

Unit

Unit

Unit

Lot

M/L

Control Cables, Flexible Conduits, Cable Tray

Lot

Manpower

Lot

Manpower, Tester and tools, Debugging Software

Lot

Manpower

Lot

Lot

L
M/L

Central Motor Control Centre ( MCC ) Monitoring and Control System - Load
Monitoring for all conveyors and elevators
- Linking Equipment Status ( Run / Stop / Trip ) to SCADA System
- Programming for Running Hours for all equipment at different stations
11.1 Remote Control Panel c/w Remote PLC including : - Power Supply
Module - CPU Module - Analog Input Module - Digital Input Module - Digital
Output Module

1
M

Lot

Floor Stand panel c/w Accessories


Fan @2pcs/panel
Cable control, terminal block, cable duct,
powersupply, Incoming Std component (MCB, Pilot
Lamp, Amperemeter), buzzer, sirinedll

M
M
M
M
M
M
M
M
M
M
M
M

PLC Set Consist :


BackLane Rack (Modular) System
Power Supply
CPU Module
D/I Module
D/O Module
A/I Module
A/O Module
Ethernet module
Relay+MCB
Timer
Accessories

Lot

M
M
M
M
M
M
M
M
M
L
11.2 To modify existing MCC panels to provide Run / Stop / Trip load free
contacts for all Motor , as per motor list
11.3 Load Sensors for Critical Equipment and conveyors
11.4 Electrical Wiring including Conduits, Cable Tray and Cables ( Control Only
)
11.5 System Installation including Wiring Check, Signal Check, Field
Debugging on Software and Linking System to SCADA System in CCR
11.6 Engineering and Software Development for Running Hour Information
System
11.7 Testing ,Commissioning and Site Training
Central Control Room
Control Room

Surge Arrester + Grounding System target 1 Ohm

M/L
M
M/L
M/L
L
L
M/L

M
M/L
M

Engineering and Software Development for Running Hour Information System


Testing ,Commissioning and Site Training
Plant-wide SCADA (Supervisory Control & Data Acquisition) Monitoring & Control
System
12.1 Hardware 1.1 SCADA (Supervisory Control and Data Acquisition) Operator
Workstation
12.1.1 DELL Compatible PC - CPU
4GB RAM Memory

12.1.2

High Resolution Graphic Card


DVD ROM Drive
Keyboard and Mouse
HDD 1TB
22" LCD Color Monitor

L
L

M
M

M
M
M
M

12.1.3 HP Graphic and Report Printer


12.1.4 1 KVA Uninterrupted Power Supply (UPS)
12.1.5 Master PLC in Central Control Room c/w Automatic Shutdown System for
SCADA Monitoring System
12.1.6 Remote Control Panel c/w PLC
12.2 1.5 Ethernet LAN Networking System including Hardware and
Communication Link
12.3 SCADA SOFTWARE

M
M

Complexity HMI Runtime Server System on Windows 7Platform

Complicity HMI Viewer System on windows 7 Platform to cater for plant-wide


Application
System Engineering and Software Development
12.4 Testing, Commissioning, Site Training, Full manual Book, All Datasheet
component & Indonesian supplier data Doc.
AutoSynchron & Load Shedding
13.1 PLC

13.2 Field Instrumentation and Equipment


AMF Module for Generator Protection & Engine Protection
ACB
MCCB
Ampere Meter ( DC Range : 0 - 30A )
Volt Meter ( Range : 0 - 30VDC )
MCB ( 1 pole , 10A , 4.5kA )
Volt Selector Switch
Auto - Man Selector switch
Emergency Stop

Selector Switches
Push Button
Relays & Contact
MCB & CB
Sirene & R. Light
Terminal Block
Cable Control
24 VDC Power Supply
Pilot Light
Engineering and Manpower for design, Wiring and
Testing
- Engineering and manpower for design ,wiring and
testing - Relays - Terminal Block - Tools &
Accessories
Load Sensor/Current Tranducer
- Control cable - Flexible Conduits - Cable Tray Manpower
- Manpower - Tester and Tools - Debugging
Software

Lot

Lot

70
1

Lot
Lot

Lot

Manpower

Lot

Manpower

Lot

Room Min 3x3M


- Window surrounding with height 1 Meter, 1.5 M from
floor
-Door
Door Closer
Surge Arrester 1KV, Copper rod 6M
Lock Mechanism RFID Reader, numeric keypad c/w
manual Lock
Manpower

Lot

1
1
1

Lot
Lot
Lot

Lot

Manpower

1
1

Lot
Lot

Set

2
1
2
1

Unit
Unit
Unit
Lot

2
1

Unit
Lot

Set

Set

1
1

Set
Set

Lot

1
4
2
2
5
5
60
5
5
5

Lot
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit
Unit

4GB RAM Memory


High Resolution Graphic Card
DVD ROM Drive
Keyboard and Mouse
HDD 1TB

M
M

M
L
L

M
M
M

M
M
M
M
M
M
M
M
M

Backlane Rack (Modular) System


Power Supply
DI/DO/AI/AO Module

Deepsea 8610
New Propose/Motor Mechanism Modification
New Propose/Motor Mechanism Modification
72x72 Hele s
72x72 Hele s
Domae ( MG )
7 pole (KNN)
3 pole (Salzer)
Rotolock (Fort)

Push Button
Pilot Lamp
Relay + Socket
Terminal Block
Baby Siren
Battery Charqer
Auxiliary material
Cu Bus bar (for additional in existing Panel)
Wiring System
Freestanding Panel (Using Existing Panel )
13.3 Installation of Instrumentation
13.4 Modification on Existing MDB Panel for Power Plant

M
M
M
M
M
M
M
M
L
M/L

13.5 Electrical Wiring Including Conduits, Cable Tray and Cables (ControlOnly)

M/L

13.6 Engineering and Programming

M/L

13.7 System Installation including Wiring Check, Signal Check, Field Debugging
on Software and Linking System to SCADA System in CCR

M/L

13.8 Testing ,Commissioning and Site Training


Air Supply System, including Air Piping Work . Air Compressors
Air Compressors
Air Compressor complete with mainline filter system for the following stations
-Sterilizer Station
-Pressing and Clarification
-Kernel Station
-Boiler & WTP Station
Motor Starter for New Air Compressors
Air Piping work complete with fitting and accessories
Air Filter Regulator and LAMAN Filter
Testing, commisioning and Site Training
Electrical Wiring Work ( For Control Only )
Transportation of Material to Indonesia
Import Duty and Tax in Indonesia
Withholding Tax in Indonesia
Accommodation And Transportation for Engineers at Site
Air Ticket
Power for Contractor

L
M/L

XB7.EA. 2 (Fort)
AXP-L44 (Fort)
LY4 (Omron)
Kasuga
Standard
220VAC/24DVC(CSS)
Japan

Manpower -

Cutting & Welding Tools

- Control cable - Flexible Conduits - Cable Tray Manpower


Manpower
- Manpower - Tester and Tools - Debugging
Software
Manpower

M/L

M
M
M
L
M/L
L
L
L
L
L
M/L

perlu didiskusikan contractor/pabrik?

4
15
40
1
5
5
1
1
1
1
1
1
1

Unit
Unit
Unit
Unit
Unit
Lot
Unit
Lot
Unit
Lot
Lot
Lot
Lot

1
1

Lot
Lot

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Lot
Lot
Lot
Lot
Unit
Unit
Unit
Unit
Lot
Lot
Lot
Lot
Lot
Lot
Lot
Lot
Lot
Lot
Lot

Grand Total Price before Duty &Tax


Plus Import Duty and Tax ( Rp )
Plus 10% PPN Tax ( Rp )
Plus 3% PPH Tax ( Rp )
Grand Total Price Ex-Indonesia

Japar Silalahi
Mill Manager SLS1

Assisten Proses

Indratno
Assisten Maintenance

Bagus Dwi Permana


MQC

Anda mungkin juga menyukai