Anda di halaman 1dari 5

VIBRATION MEASUREMENT REPORT

Vibration Measurements for SoC (Statement of Compliance) on board vessels according to


ISO 6954 Edition 2000
I. General Data
1

Class/Reg.-No.:

RNR /64

IMO-No.:

46000310

Shipyard:

Santier Naval Galati

Yard Building-No.:

1967

Ships Name:

COLEGIU

Measurement according to
Guideline/Standard:

ISO 6954 Edition 2000


(Upper Limit)

Shipowner:

UGAL

Flagstate:

ROMANIA

Prodan Ionut

Expert(s) in Charge:

C.G.

Issue date of the Report:

11.09.2014

5 Measurement Company:
6
7

Report-No.:

Measurements were carried out on behalf of:

Universitatea Dunarea de Jos - Galati

II. Hull Data


8

Type of Ship:

Length (Lpp) [m]:

25.70

Breadth [m]:

4.40

10

Depth [m]:

1.60

Scantling Draught [m]:

1.22

11

Gross Tonnage [t]:

6.8

Design Speed [km/h]:

18

Passenger vessel

12

Remarks: -

III. Nominal Machinery Data


13 Main Engine

Manufacturer:

URSS

Type:

14

Number of Units:

No. of Cyl./Stroke:

15

Power MCR [kW]:

220.8

Revolution Rate [rpm]:

16

Engine Mounting:

17

Gearbox

DIESEL

1500

Rigid

Manufacturer:

URSS

Type:

REDUCTOR

18

Number of Units:

Reduction Ratio:

1/3

19

Power Rating [kW]:

Manufacturer:

Santierul Naval
Galati

Kind of propeller:

fixed pitch

21

Number of Propellers:

Number of Blades:

22

Diameter:

1m

Nominal Revolution Rate


[rpm]:

500

20

23

Propeller

Remarks:

IV. Machinery Condition during Measurement


24

Main
Engine

Number of Units in
Op.:

25

Total Power [kW]: 189


Shaft Generator
[kW]:

Revolution rate [rpm]: 1250

26 Propeller

N/A

FPP (Fixed Pitch)

27

Revolution rate [rpm]:

28

Propeller Pitch []:

29

Aux.
Engine

416.66
N/A

Number of Units in
Op.:

30

Revolution rate [rpm]:

Engine
29 room
ventilation

Number of Units in
Op.:

30

Revolution rate [rpm]:

31 Remarks:

Power Rating [kW]:

35

1850

Power Rating [kW]:


Operating mode:
high/how/variable

NATURAL VENTILATION

V. Environmental and Hull Floating Condition during Measurement


32 Kind of Voyage

Loaded Voyage

33 Date /Time Date of measurements:

18.05.2014

34

Starting Time:

13:30

Finished:

17:30

35 Draught

Aft [m]:

1.20

Forward [m]:

1.15

36

Water
Depth

25 [m]

37 Weather

Wind Speed [bft]:

38 Sea Area

Area:

Sea State:

2
DANUBE RIVER

39 Remarks:

VI. Measurement Equipment


40 Analyser

Type:

HVM 100

Manufacturer:

LARSON DAVIS

41

Serial-No:

01681

Last Calibration:

2014-05-18

42 Transducer

Type:

SENO21F

Manufacturer:

LARSON DAVIS

43

Serial-No:

P84876

Last Calibration:

2014-05-18

44

Mounting
Method:

Magnetic

VII. Signal Processing


47 Analysis Parameter

Sampling
Frequency:

1 Hz

Measurement Time
1 seconds
per Point:

48

Averaging
Mode:

Slow

Frequency
Resolution:

49

Sampling
Window:

50

Time Signal
available:

11 Hz

Flat Top

11 seconds

Frequency Spectrum
available:
Fa 0.4-100 Hz

VIII. Measurement Results (ISO 6954 Edition 2000)


51

Measurement
Point No.

Measurement Location/
Description

Direction
(x, y, z)

VOA **)
[mm/s]

Limit Value
[mm/s] ***)

LV1

Open Deck

X,Y,Z

LV2

Aft

LV3

Aft Saloon

X,Y,Z

LV4

Fore Saloon

X,Y,Z

LV5

Fore Saloon

X,Y,Z

Spectrum Plot.
Figure No.

X,Y,Z

*) According to the measurement location plan enclosed (see Appendix A)


**) VOA: Overall frequency weighted r.m.s.-values (1 80 Hz) of vibration velocity
***) According ISO 6954 Edition 2000 upper value

IX. Final Statements to the Measurement Report


52 Statement: Expert in Charge
Herewith it is confirmed that all measurements were carried out according to the above mentioned
standard/regulation.

Ship: Colegiu

18.05.2014

Place

C.G.
Date

Signature (Expert in charge)

53 Statement: Representatives
Herewith we confirm that vibration measurements on board the above mentioned vessel were carried out.

Ship: Colegiu
Place

18.05.2014

Bosoanca Ioan
Date

Appendix A

Professor (Grade)

Required Measurement Locations and Directions


Measurement
Point No.
LV1
LV2
LV3
LV4
LV5

Measurement Location/Description
Promenade Deck
Open Deck
Main Deck
Aft Ship
Aft Saloon
Fore Saloon
Fore Saloon

Spectrum

Direction
(X,Y,Z)

D 114

X,Y,Z

D 90
D 102
D 61
D 60

X,Y,Z
X,Y,Z
X,Y,Z
X,Y,Z

Anda mungkin juga menyukai